Switch Disconnectors & Control Stations
2015.1
Cover:See separate Sheet
www.craigandderricott.com
Page
1
Introduction & Index As a wholly British owned company Craig & Derricott have been designing, manufacturing and supplying low voltage electrical control and switchgear for over 70 years. Today our customers extend around the world and operate in a wide variety of markets and sectors including Railway, Construction, Ventilation (Fire rated), Explosion proof, Medical, Military, Panel builders and Power & Distribution. Based in the UK and certified to ISO 9001 we offer a wide range of assembled Electrical isolation and Control station products in the UAE region which are detailed in this catalogue. These are supported by a bespoke and special product service known as Mi switch, enabling customers to specify exact requirements which can be made to order. Simply contact your local Area Sales Manager to discuss your requirements.
Index
This catalogue covers our ‘Building Services’ products. Range
switch Enclosed Isolators
switch Panel Isolators
push Control Stations
m
Page
1
switch
Description
Page
Plastic Enclosed
3
Die-Cast Aluminium Enclosed
5
Sheet Steel Enclosed - Mild Steel
7
Sheet Steel Enclosed - with Defeatable Door Interlock Handle
8
Stainless Steel Enclosed
9
Sloping Roof Stainless Steel Enclosed
10
Flush Mounting Stainless Steel
11
Technical Data
12
Hinged Door Sheet Steel
13
Fire Rated - F300 / F400
15
LUL ‘Section 12’ Equipment
17
Dimensions and Fixings
19
Exe IECEx / ATEX Zone 1 & 2 Isolators
23
Exe IECEx / ATEX Zone 1 & 2 Dimensions
25
Exd ATEX Zone 1/21 & 2/22
26
Fire Rated - F200
28
Compact Panel Isolators 25A - 200A
29
Standard Panel Isolators 100A - 1000A
31
Panel Isolator Technical Data
33
Compact Panel Isolator Dimensions
34
Standard Panel Isolator Dimensions
35
Changeover Isolators 32A - 630A
36
Changeover Isolators Dimensions
37
Introduction
38
Emergency Stops
40
Emergency Power Off (EPO)
44
Accessories
44
Dimensions
46
Bespoke Assemblies
47
Product Guide & IP Data Product Guide
Product definitions and Utilisation categories to IEC 60947-3 Technical Description
Utilisation Category
A ‘Disconnector’ is a mechanical switch which in the ‘Open’ position, complies with requirements specified for the isolating function. A ‘Disconnector’ or ‘Isolator’ is an off-load device and marked ‘Isolate elsewhere before opening’ they have an AC20/DC20 utilisation category.
AC20
Connecting & disconnecting under ‘no-load’ conditions.
AC21
Switching of resistive loads including moderate overloads.
AC22
Switching of mixed resistive/inductive loads including moderate overloads.
AC23
Switching of highly inductive loads (Capable of safely isolating a motor even under stalled conditions e.g. chiller unit)
Definition
Switch-Disconnector Sym.
A ‘Switch’ is a mechanical switching device capable of making, carrying and breaking current under normal circuit conditions, which may include specified operating overload conditions. They also carry, for a specified time, currents under specified abnormal circuit conditions, such as those of short circuit (i.e. Utilisation category AC23A duty). A ‘Switch-Disconnector’ meets both of these criteria and with a Red/Yellow padlockable handle may also be called a ‘Safety Isolator’.
Description
Frequent and Infrequent Use. The categories above can be suffixed to indicate a frequency of use:Frequent Use (A) Up to 5 times a day for small devices (typically up to 100A), once a week for larger items. Infrequent Use (B) Once a week for smaller devices, once a month for the larger items.
Ingress Protection
When choosing an isolating device, apart from the electrical performance, consideration must be given to the environmental conditions in which the device will be placed. The item may be subjected to dust or dirt or it may come in contact with degrees of moisture. Indoor conditions will vary considerably but items may well be placed outdoors where the full influence of rain, ice & snow will be present. Protecting items to varying degrees is detailed in BS EN 60529:1992. Employing a two digit code the standard defines protection against solid objects and separately protection against moisture i.e.
IP66
(protection against solid objects) (protection against water)
The following extract defines the IP categories used within this document. 1st Digit
Protection against solid objects
2nd Digit
Protection against water
0
Not Protected
0
Not Protected
2
Ø12.5
Protected against solid objects greater than Ø12.5
1
Protected against dripping water.
4
Ø1.0
Protected against solid objects greater than Ø1.0
4
Protected against splashed water from any direction.
5
Protected against dust allowing a degree of ingress that isn’t harmful to the assembly.
5
Protected against water jets from any direction.
6
No ingress of dust.
6
Protected against strong water jets from any direction.
Please refer to BS EN 60529:1992 for full details.
www.craigandderricott.com
Page
2
Enclosed Isolators
Plastic Enclosed General Description
Switch-disconnectors housed in moulded plastic enclosures provide the basis for most industrial applications and the added benefits offered by the ‘i-switch’ range provide the user with a wealth of opportunities when selecting the correct item for a specific application. Sealing up to IP66 is a standard feature as is the ability to add a selection of auxiliary blocks providing additional contacts and a choice of Neutral assemblies. With the ‘i-switch’ range comes an important safety feature which prevents the enclosure cover being removed when the device has been padlocked in the ‘Off’ position. When combined with the excellent on-load breaking capacity of the ‘i-switch’ family this feature ensures that the term ‘Safety Switch’ is fully satisfied.
Switch-Disconnectors (O-I)
Catalogue Numbers Rating
20A
25A
32A
Safety Features Padlocking All items allow for the insertion of up to three padlocks in the ‘Off’ position thus preventing the isolator being switched to the ‘On’ position.
40A
Standard shackle diameter Ø6.4
63A
Safety Interlock
80A
Screwed lid enclosures have always been open to abuse by having the lid removable when the isolator is ‘Off’ and padlocked. This would allow the switch shaft to be turned manually to the ‘On’ position, thus defeating the safety padlocking feature. The ‘i-switch’ range now incorporates a mechanical interlock which when a padlock is inserted prevents the enclosure lid from being removed.
100A
Format
Interior Switch product range
Cat. No.
6P 6P+2EB Aux 2P 3P 3P+NL 3P+N 3P+2EB Aux 2P 3P 3P+NL 3P+N 3P+2EB Aux 2P 3P 3P+NL 3P+N 3P+2EB Aux 6P 6P+2EB Aux 2P 3P 3P+NL 3P+N 3P+2EB Aux 2P 3P 3P+NL 3P+N 3P+2EB Aux 2P 3P 3P+NL 3P+N 3P+2EB Aux
GX20 GX20 CS25 CS25 CS25 CS25 CS25 CS32 CS32 CS32 CS32 CS32 CS40R CS40R CS40R CS40R CS40R GX40 GX40 CS63 CS63 CS63 CS63 CS63 CS80 CS80 CS80 CS80 CS80 CS100 CS100 CS100 CS100 CS100
SDP206 SDP206EB SDP252 SDP253 SDP253NL SDP253N SDP253EB SDP322 SDP323 SDP323NL SDP323N SDP323EB SDP402 SDP403 SDP403NL SDP403N SDP403EB SDP406 SDP406EB SDP632 SDP633 SDP633NL SDP633N SDP633EB SDP802 SDP803 SDP803NL SDP803N SDP803EB SDP1002 SDP1003 SDP1003NL SDP1003N SDP1003EB
Enclosure Size
A (IP66) A (IP66)
A (IP66)
B (IP66)
B (IP66)
C (IP65)
D (IP65)
‘N’ = Switched neutral (Early make, late break) ‘NL’ = Unswitched neutral ‘EB’ = Early break auxiliary contacts
If you require padlocking in both the ‘Off’ & ‘On’ positions then add a ‘/10’ to the catalogue number i.e. SDP633EB/10
Changeover Switch-Disconnectors (I-O-II)
Technical Data Pg 12 Dimensions Pg 19
Page
3
Watch a 3 minute video explaining the various safety features built-in to the design of the i-switch ‘screwed lid’ product family.
Catalogue Numbers Rating
20A
40A
Format
Interior Switch product range
Cat. No.
2P 3P 4P 2P 3P 4P
GX20 GX20 GX20 GX40 GX40 GX40
SCODP202 SCODP203 SCODP204 SCODP402 SCODP403 SCODP404
Enclosure Size
A (IP66) B (IP66)
Accessories Applicable to type ‘CS’ interiors only
Catalogue Numbers Description
Neutral Link (Unswitched)
2 Early Break Auxiliary
Neutral Link (Switched)
Cat. No.
Auxiliary Contact - 2 Early Break
SAUX2EB
Auxiliary Contact - 1 N/O + 1 N/C
SAUXCO
25A Neutral (Unswitched)
SNL25
32A & 40A Neutral (Unswitched)
SNL40
63A Neutral (Unswitched)
SNL63
80A Neutral (Unswitched)
SNL80
100A Neutral (Unswitched)
SNL100
25A Neutral (Switched)
SSP25
32A & 40A Neutral (Switched)
SSP40
63A Neutral (Switched)
SSP63
80A Neutral (Switched)
SSP80
100A Neutral (Switched)
SSP100
Enclosed Isolators
Plastic Enclosed
All switched neutral blocks have ‘Early make, late break’ contacts.
Design Features Enclosure Material 20A-63A PC/ABS 80A-100A PC Colour
Enclosure - Grey RAL 7035
Entries Size A Enclosure - 2 x M20 knock-outs on top & bottom faces. Size B Enclosure - 2 x M20/25 knock-outs on top & bottom faces. Back face - 2 x M20 knock-outs. Size C & D Enclosures - Blank sides. Cover Screws
Stainless Steel (Captive)
Fixings
Outside sealed cavity.
Switch-Disconnectors KEMA certified 2 & 3 Pole
Type CS - base mounted. (Accepts add-on Aux. blocks & Neutrals)
6 Pole
Type GX - base mounted. (also available with 2 E/B Aux.)
Changeover Switch-Disconnectors KEMA certified 2, 3 & 4 Pole
Type GX - base mounted.
Earthing KEMA certified Earth terminals are provided in the base of the enclosures. Technical Data Pg 12 Dimensions Pg 19
www.craigandderricott.com
Page
4
Die-Cast Aluminium Enclosed Enclosed Isolators
General Description
The ‘i-switch’ die-cast range provides the user with a product that will withstand a good deal of rough treatment. With sealing up to IP66 these assemblies can be placed in environments where resistance to impacts, moisture and dust/dirt are a concern. The ‘i-switch’ range now incorporates a mechanical interlock which when a padlock is inserted prevents the enclosure lid from being removed. All safety features are identical to the plastic moulded range - see page 3 for details.
Switch-Disconnectors (O-I)
Catalogue Numbers Rating
20A
25A
32A
40A
63A
80A
Technical Data Pg 12 Dimensions Pg 20
Page
5
Size B
Format
6P 6P+2EB Aux 2P 3P 3P+N 3P+NL 3P+2EB Aux 2P 3P 3P+N 3P+NL 3P+2EB Aux 2P 3P 3P+N 3P+NL 3P+2EB Aux 6P 6P+2EB Aux 2P 3P 3P+NL 3P+N 3P+2EB Aux 2P 3P 3P+N 3P+NL 3P+2EB Aux 6P 6P+2EB Aux 3P 3P+NL 3P+N
Interior Switch product range
Catalogue Nos. (Grey) Bottom cable entries only (X)
SDDG206X GX20 SDDG206EBX GX20 SDDG252X CS25 SDDG253X CS25 SDDG253NX CS25 SDDG253NLX CS25 SDDG253EBX CS25 SDDG322X CS32 SDDG323X CS32 SDDG323NX CS32 SDDG323NLX CS32 SDDG323EBX CS32 SDDG402X CS40R SDDG403X CS40R SDDG403NX CS40R CS40R SDDG403NLX CS40R SDDG403EBX SDDG406X GX40 SDDG406EBX GX40 SDDG402TX CS40 SDDG403TX CS40 CS40 SDDG403NLTX SDDG403NTX CS40 CS40 SDDG403EBTX SDDG632X CS63 SDDG633X CS63 SDDG633NX CS63 SDDG633NLX CS63 SDDG633EBX CS63 SDDG636X CS63 SDDG636EBX CS63 SDDG803X CS80 SDDG803NLX CS80 SDDG803NX CS80
Top & Bottom cable entries (Y)
SDDG206Y SDDG206EBY SDDG252Y SDDG253Y SDDG253NY SDDG253NLY SDDG253EBY SDDG322Y SDDG323Y SDDG323NY SDDG323NLY SDDG323EBY
Enclosure Size
A (IP66)
A (IP66)
SDDG403NY SDDG403NLY
A (IP66)
SDDG403EBY SDDG406Y SDDG406EBY SDDG402TY SDDG403TY SDDG403NLTY
B (IP66)
SDDG403NTY SDDG403EBTY SDDG632Y SDDG633Y SDDG633NY SDDG633NLY SDDG633EBY
B (IP66)
SDDG636Y SDDG636EBY SDDG803Y SDDG803NLY SDDG803NY
C/O Switch-Disconnectors (I-O-II)
Catalogue Numbers Rating Format
20A
SDDG402Y SDDG403Y
Size A
A (IP66)
B (IP66)
‘N’ = Switched neutral (Early make, late break) ‘NL’ = Unswitched neutral ‘EB’ = Early break auxiliary contacts ‘X’ = Bottom cable entries only ‘Y’ = Top and bottom cable entries ‘T’ = Increased terminal capacity
If you require padlocking in both the ‘Off’ & ‘On’ positions then add a ‘/10’ to the catalogue number i.e. SDDG403NX/10
40A
Interior Switch product range
Cat. Nos.
Cat. Nos.
(Bottom cable entries only)
(Top & bottom cable entries)
2P
GX20
SCODDG202X SCODDG202Y
3P
GX20
SCODDG203X SCODDG203Y
4P
GX20
SCODDG204X SCODDG204Y
2P
GX40
SCODDG402X SCODDG402Y
3P
GX40
SCODDG403X SCODDG403Y
4P
GX40
SCODDG404X SCODDG404Y
Enclosure Size
A (IP66) B (IP66)
Die-Cast Aluminium Enclosed Enclosed Isolators
Accessories Applicable to type ‘CS’ interiors only
Catalogue Numbers Description Auxiliary Contact - 2 Early Break Auxiliary Contact - 1 N/O + 1 N/C 25A Neutral (Unswitched) 32A & 40A Neutral (Unswitched) 63A Neutral (Unswitched) 80A Neutral (Unswitched) 25A Neutral (Switched) 32A & 40A Neutral (Switched) 63A Neutral (Switched) 80A Neutral (Switched)
Cat. No. SAUX2EB SAUXCO SNL25 SNL40 SNL63 SNL80 SSP25 SSP40 SSP63 SSP80
All switched neutral blocks have ‘Early make, late break’ contacts.
Exploded view of a die cast assembly showing the type ‘CS’ isolator interior.
Design Features
Assembly Sealing to IP66 Enclosure Material
Die-cast aluminium alloy LM24 (BS1490) AL - Si8Cu3Fe
Paint finish
Grey - RAL 7035 Chromate pre-treatment and smooth power coat finish. Style ‘Y’
Entries
Included with std. catalogue No:-
Style X - Bottom entries only Style Y - Bottom/top
Cover Screws
Stainless Steel (Captive)
Earthing
Terminals are provided on both lid and base to allow full earth continuity to be maintained
Mounting
All fixings are internal but outside of the IP66 sealed area. Guide channels are provided to assist with the fixing screw location.
Style ‘X’
Style ‘Y’ has been designed and manufactured specifically to give the installer the flexibility to have cable entry top and bottom. The ‘X’ version offers the installer cable entry at bottom only but has the advantage of guaranteeing IP rating is not compromised due to an installation fault or abuse.
Switch-Disconnectors KEMA Certified 2, 3 & 6 Pole
Type CS - base mounted. (Accepts add-on Aux. blocks & Neutrals)
6 Pole
Type GX - base mounted. (also available with 2 E/B Aux.)
Changeover Switch-Disconnectors Technical Data Pg 12
KEMA Certified 2, 3 & 4 Pole
Type GX - base mounted.
Dimensions Pg 20
www.craigandderricott.com
Page
6
Sheet Steel Enclosed Enclosed Isolators
Mild Steel General Description
Switch-disconnectors housed in mild steel enclosures provides the user with a robust and cost effective assembly along with the added features offered by the ‘i-switch’ range. Sealing to IP66 is a standard feature as is the ability to add a selection of auxiliary blocks and a choice of Neutral assemblies. All safety features are identical to the plastic moulded range - see page 3 for details.
Switch-Disconnectors (O-I)
Catalogue Numbers Rating
20A
25A
32A
40A
63A
Format
Interior Switch product range
6P 6P+2EB 2P 3P 3P+NL 3P+N 3P+2EB 2P 3P 3P+NL 3P+N 3P+2EB 2P 3P 3P+NL 3P+N 3P+2EB 6P 6P+2EB 2P 3P 3P+NL 3P+N 3P+2EB
GX20 GX20 CS25 CS25 CS25 CS25 CS25 CS32 CS32 CS32 CS32 CS32 CS40R CS40R CS40R CS40R CS40R GX40 GX40 CS63 CS63 CS63 CS63 CS63
Cat. No. Std Handle (IP66)
SDMG206 SDMG206EB SDMG252 SDMG253 SDMG253NL SDMG253N SDMG253EB SDMG322 SDMG323 SDMG323NL SDMG323N SDMG323EB SDMG402 SDMG403 SDMG403NL SDMG403N SDMG403EB SDMG406 SDMG406EB SDMG632 SDMG633 SDMG633NL SDMG633N SDMG633EB
Enclosure Size
A
A
A
Enclosure
B
B
KEMA Certified
Changeover Switch-Disconnectors (I-O-II)
Catalogue Numbers
20A
40A
Technical Data Pg 12 Dimensions Pg 19
Page
7
Material Sheet steel, thickness 1.2mm Paint finish Epoxy Powder Coated. Colour Enclosure - Grey RAL 7035 Fitting 20A-32A Size A, 40A-63A Size B Entries Size A Enclosure - 2 x M20 Size B Enclosure - 2 x M20 + 2 x M25 Cover Screws Stainless Steel (Captive) External Feet Size A enclosure - Cat. No. EFA Size B enclosure - Cat. No. EFB (See over for dimensions) Switch-Disconnectors
‘N’ = Switched neutral (Early make, late break) ‘NL’ = Unswitched neutral ‘EB’ = Early break auxiliary contacts
Rating
Design Features
2 & 3 Pole
Type CS - base mounted. (Accepts add-on Aux. blocks & Neutrals)
6 Pole
Type GX - base mounted. (also available with 2 E/B Aux.)
Changeover Switch-Disconnectors
Format
Interior Switch product range
Cat. No.
2P 3P 4P 2P 3P 4P
GX20 GX20 GX20 GX40 GX40 GX40
SCODMG202 SCODMG203 SCODMG204 SCODMG402 SCODMG403 SCODMG404
Enclosure Size
A
B
(If you require padlocking in both the ‘Off’ & ‘On’ positions then add a ‘/10’ to the catalogue number i.e. SDMG323NL/10.
KEMA Certified 2, 3 & 4 Pole
Type GX - base mounted.
Earthing Earth continuity terminals are provided in the base and lid of each enclosure.
With Defeatable Door Interlock Handle General Description
This version of the sheet steel enclosure range includes a Defeatable Door Interlock Handle with all of the safety features found on the standard range but adds an override facility which allows the screwed lid to be removed in the ‘On’ position for testing purposes. Sealing to IP65.
Switch-Disconnectors (O-I)
Catalogue Numbers Rating
20A
25A
32A
40A
63A
Format
6P 6P+2EB Aux 2P 3P 3P+NL 3P+N 3P+2EB Aux 2P 3P 3P+NL 3P+N 3P+2EB Aux 2P 3P 3P+NL 3P+N 3P+2EB Aux 6P 6P+2EB Aux 2P 3P 3P+NL 3P+N 3P+2EB Aux
Interior Switch product range
GX20 GX20 CS25 CS25 CS25 CS25 CS25 CS32 CS32 CS32 CS32 CS32 CS40R CS40R CS40R CS40R CS40R GX40 GX40 CS63 CS63 CS63 CS63 CS63
Cat. No.
SDMG206/H2 SDMG206EB/H2 SDMG252/H2 SDMG253/H2 SDMG253NL/H2 SDMG253N/H2 SDMG253EB/H2 SDMG322/H2 SDMG323/H2 SDMG323NL/H2 SDMG323N/H2 SDMG323EB/H2 SDMG402/H2 SDMG403/H2 SDMG403NL/H2 SDMG403N/H2 SDMG403EB/H2 SDMG406/H2 SDMG406EB/H2 SDMG632/H2 SDMG633/H2 SDMG633NL/H2 SDMG633N/H2 SDMG633EB/H2
Encl. Size
A
A
A
Design Features Enclosure Material Sheet steel, thickness 1.2mm Paint finish Iron phosphate pre-treatment & epoxy powder coat smooth finish. Colour Enclosure - Grey RAL 7035 Entries Size A Enclosure - 2 x M20 Size B Enclosure - 2 x M20 + 2 x M25 Cover Screws Stainless Steel (Captive) External Feet Size A enclosure - Cat. No. EFA Size B enclosure - Cat. No. EFB
Enclosed Isolators
Sheet Steel Enclosed
Switch-Disconnectors KEMA Certified B
2 & 3 Pole
Type CS - base mounted. (Accepts add-on Aux. blocks & Neutrals)
6 Pole
Type GX - base mounted. (also available with 2 E/B Aux.)
Changeover Switch-Disconnectors B
‘N’ = Switched neutral (Early make, late break) ‘NL’ = Unswitched neutral ‘EB’ = Early break auxiliary contacts
KEMA Certified 2, 3 & 4 Pole
Type GX - base mounted.
Earthing Earth continuity terminals are provided in the base and lid of each enclosure.
(If you require padlocking in both the ‘Off’ & ‘On’ positions then add a ‘/10’ to the catalogue number i.e. SDMG323NL/10.
Accessories
Insert a small diameter tool, such as a screwdriver to override the lid interlock.
Applicable to type ‘CS’ interiors only
Catalogue Numbers Description Auxiliary Contact - 2 Early Break Auxiliary Contact - 1 N/O + 1 N/C 25A Neutral (Unswitched) 32A & 40A Neutral (Unswitched) 63A Neutral (Unswitched) 25A Neutral (Switched) 32A & 40A Neutral (Switched) 63A Neutral (Switched)
Cat. No. SAUX2EB SAUXCO SNL25 SNL40 SNL63 SSP25 SSP40 SSP63
All switched neutral blocks have ‘Early make, late break’ contacts. Technical Data Pg 12 Dimensions Pg 19
www.craigandderricott.com
Page
8
Stainless Steel Enclosed Enclosed Isolators
General Description
Switch-disconnectors housed in stainless steel enclosures provides the user with an assembly that can be installed in the harshest of environments. Outdoor in unprotected positions or indoor and subject to severe environmental conditions, the standard stainless steel i-switch range with a flush back surface offers the ideal solution. Sealing to IP66 is a standard feature as is the ability to add a selection of auxiliary blocks providing additional contacts and a choice of Neutral assemblies. External mounting feet in stainless steel are offered as an accessory sized to match each enclosure. All safety features are identical to the plastic moulded range - see page 3 for details. The defeatable door interlock handle option provides an override facilty which allows the lid to be removed in the ‘On’ position for testing purposes.
Standard Switch-Disconnectors (O-I)
Catalogue Numbers Rating
20A
25A
32A
Design Features
40A
Enclosure (Flush rear surface) Material Stainless steel, Grade 304, thickness 1.2mm (Grade 316 to special order) Finish Brushed Satin (150 grit) Entries Size A Enclosure - 2 x M20 Size B Enclosure - 2 x M20 + 2 x M25 Cover Screws Stainless Steel (Captive) External Feet Size A enclosure - Cat. No. EFA Size B enclosure - Cat. No. EFB Switch-Disconnectors
2 & 3 Pole
Type CS - base mounted. (Accepts add-on Aux. blocks & Neutrals)
6 Pole
Type GX - base mounted. (also available with 2 E/B Aux.)
Changeover Switch-Disconnectors KEMA Certified
Dimensions Pg 19
Page
9
2, 3 & 4 Pole
Interior Switch product range
Std. Handle (IP66)
H2 Handle (IP65)
6P 6P+2EB Aux 2P 3P 3P+NL 3P+N 3P+2EB Aux 2P 3P 3P+NL 3P+N 3P+2EB Aux 2P 3P 3P+NL 3P+N 3P+2EB Aux 6P 6P+2EB Aux 2P 3P 3P+NL 3P+N 3P+2EB Aux
GX20 GX20 CS25 CS25 CS25 CS25 CS25 CS32 CS32 CS32 CS32 CS32 CS40R CS40R CS40R CS40R CS40R GX40 GX40 CS63 CS63 CS63 CS63 CS63
SDS206 SDS206EB SDS252 SDS253 SDS253NL SDS253N SDS253EB SDS322 SDS323 SDS323NL SDS323N SDS323EB SDS402 SDS403 SDS403NL SDS403N SDS403EB SDS406 SDS406EB SDS632 SDS633 SDS633NL SDS633N SDS633EB
SDS252/H2 SDS253/H2 SDS253NL/H2 SDS253N/H2 SDS253EB/H2 SDS322/H2 SDS323/H2 SDS323NL/H2 SDS323N/H2 SDS323EB/H2 SDS402/H2 SDS403/H2 SDS403NL/H2 SDS403N/H2 SDS403EB/H2 SDS406/H2 SDS406EB/H2 SDS632/H2 SDS633/H2 SDS633NL/H2 SDS633N/H2 SDS633EB/H2
Catalogue No.
Enclosure Size
A
A
A
B
B
‘N’ = Switched neutral (Early make, late break) ‘NL’ = Unswitched neutral ‘EB’ = Early break auxiliary contacts
(If you require padlocking in both the ‘Off’ & ‘On’ positions then add a ‘/10’ to the catalogue number i.e. SDS323NL/10.
Changeover Switch-Disconnectors (I-O-II)
KEMA Certified
Technical Data Pg 12
63A
Format
Type GX - base mounted.
Earthing Earth continuity terminals are provided in the base and lid of each enclosure.
Catalogue Numbers Rating
20A
40A
Format
Interior Switch product range
Cat. No.
2P 3P 4P 2P 3P 4P
GX20 GX20 GX20 GX40 GX40 GX40
SCODS202 SCODS203 SCODS204 SCODS402 SCODS403 SCODS404
Enclosure Size
A (IP66) B (IP66)
Sloping Roof Stainless Steel Enclosed Based upon Craig & Derricott’s ‘i-switch’ range of isolation equipment, the specially designed stainless steel ‘sloping roof’ enclosure is ideally suited for hygienic environments with their associated severe cleaning routines. The design has been created to minimise areas where dirt can accumulate and incorporates a flush rear surface and universal fixing that include IP66 sealings. All safety features are identical to the plastic moulded range - see page 3 for details.
Sloping Roof Switch-Disconnectors (O-I)
Catalogue Numbers Rating
20A
25A
32A
40A
Design Features Enclosure (Flush rear surface)
63A
Material Stainless steel, Grade 316, thickness 1.2mm body, 1.5mm lid. (15° Slope) Finish Brushed Satin 150 grit Entries The enclosures are supplied as standard without entries. Optional pre-drilled bottom entries can be supplied as follows: Size A - 2xM20 (add M20 to cat No.) Size B - 2xM25 (add M25 to cat No.) e.g. SDSSR322/M20, SDSSR403N/M25 Cover Screws Stainless Steel (Captive) Fixings Universal fixings across the range.
Switch-Disconnectors KEMA Certified
Safety 2 & 3 Pole 6 Pole
Features Type CS - base mounted.
(Accepts add-on Aux. blocks & Neutrals)
Format
Interior Switch product range
Cat. No.
Encl. Size
6P 6P+2EB AUX 2P 3P 3P+2EB AUX 3P+N 2P 3P 3P+2EB AUX 3P+N 2P 3P 3P+2EB AUX 3P+N 6P 6P+2EB AUX 2P 3P 3P+2EB AUX 3P+N
GX20 GX20 CS25 CS25 CS25 CS25 CS32 CS32 CS32 CS32 CS40R CS40R CS40R CS40R GX40 GX40 CS63 CS63 CS63 CS63
SDSSR206 SDSSR206EB SDSSR252 SDSSR253 SDSSR253EB SDSSR253N SDSSR322 SDSSR323 SDSSR323EB SDSSR323N SDSSR402 SDSSR403 SDSSR403EB SDSSR403N SDSSR406 SDSSR406EB SDSSR632 SDSSR633 SDSSR633EB SDSSR633N
A (IP66) A (IP66)
A (IP66)
Enclosed Isolators
General Description
B (IP66)
B (IP66)
‘N’ = Switched neutral (Early make, late break) ‘EB’ = Early break auxiliary contacts
(If you require padlocking in both the ‘Off’ & ‘On’positions then add a ‘/10’ to the catalogue number i.e. SDSSR323NL/10)
Accessories Applicable to type ‘CS’ interiors only
Catalogue Numbers Description Auxiliary Contact - 2 Early Break Auxiliary Contact - 1 N/O + 1 N/C 25A Neutral (Unswitched) 32A & 40A Neutral (Unswitched) 63A Neutral (Unswitched) 80A Neutral (Unswitched) 25A Neutral (Switched) 32A & 40A Neutral (Switched) 63A Neutral (Switched) 80A Neutral (Switched)
Cat. No. SAUX2EB SAUXCO SNL25 SNL40 SNL63 SNL80 SSP25 SSP40 SSP63 SSP80
All switched neutral blocks have ‘Early make, late break’ contacts.
Type GX - base mounted. (also available with 2 E/B Aux.)
Earthing Earth continuity terminals are provided in the base and lid of each enclosure.
Technical Data Pg 12 Dimensions Pg 19
www.craigandderricott.com
Page
10
Enclosed Isolators
Flush Mounting Stainless Steel General Description
Craig & Derricott have been manufacturing flush mounting isolators for more than 70 years and in that time the design has been carefully modified to give features that installers and end users really need. The assembly consists of a zinc plated back box (complete with knock-outs) and a stainless steel fascia plate which carries the isolating switch and lockable handle. The fascia plate now comes in an attractive brushed finish which resists the fingerprint effect associated with highly polished surfaces. Equally at home in kitchens, laboratories, food processing areas, hospitals and many other areas where an elegant, low projection isolation device is required.
Switch-Disconnectors (O-I)
Catalogue Numbers Rating
20A
32A
40A
63A
Design Features
Format
2P 3P 4P 2P 3P 4P 2P 3P 4P 2P 3P 4P
Interior Switch product range
GX
GX
GX
GN
Cat. No.
Enclosure Size
SDFL202 SDFL203 SDFL204 SDFL322 SDFL323 SDFL324 SDFL402 SDFL403 SDFL404 SDFL632 SDFL633 SDFL634
Enclosure
Sealing
Fascia plate Stainless steel 304, thickness 1.2mm Finish Brushed.
Isolating switch to stainless steel fascia plate - IP66. Fascia plate securing screws
Back box Sheet steel, thickness 1.4mm Finish Galvanised
Stainless steel (M5 x 25 with ‘Allen Key’ head).
Entries
Earthing
Knockouts in back box.
Separate earthing points on fascia plate and back box.
Installation
Whilst the joint between the isolating switch and the stainless steel fascia plate is factory sealed to IP66 min, when installed, the fascia to mounting surface seal is the responsibility of the installer. To maintain the sealing overall, an efficient bond must be made using some form of gasketing material. This is particularly vital on tiled surfaces where grout lines can channel moisture down the wall. A continuous bead of moisture resistant mastic is a simple way of providing a seal, and can improve the appearance of the final assembly on an uneven surface.
Technical Data Pg 12 Dimensions Pg 19
Page
11
Typical Installation (‘D’ max = 20mm with standard length mounting screws
A
B
B
C
Technical Data for pages 3-11 Rating
Data supplied against tests to IEC/BS EN 60947-3 Application
Sym.
Unit
Switch product range
Category
20A
25A
32A
40A
63A
80A
100A
-
-
GX20
CS25
CS32
GX40
CS40
CS40R
CS63
CS80
CS100
Rated thermal current
Ithe
A
20
25
32
40
40
40
63
80
100
Rated insulation voltage
Ui
V
690
690
690
690
690
690
690
690
1000
Uimp
kV
6
6
6
6
6
6
6
6
8.0
Rated operational power (3 phase AC)
Pe
kW
Rated short time withstand current (1 sec)
Icw
Rated impulse voltage
Max. fuse size for short circuit protection (gG Characteristic)
Recommended connecting capacity
380/440 - AC23
7.5
11
15
18.5
18.5
15
25
30
59
500V - AC23
7.5
15
15
15
22
15
30
37
63
690V - AC23
7.5
15
15
15
22
15
30
30
51
250
500
600
800
1100
600
1300
1400
2600
A
kA
10kA
20
35
35
40
80
40
80
80
160
25kA
16
32
32
35
80
32
63
63
160
50kA
-
32
32
-
80
32
63
63
160
6
6
6x2
16
6
16
16
50
-
Terminal type
mm2
Flexible cable
2.5 x 2
Rigid cable
2.5 x 2
10
10
10 x 2
25
10
25
25
70
Tightening torque
1.0
1.2
1.2
1.0
1.2
1.2
1.2
1.2
2
Category
Sym.
Unit
Rating
-
Ui
V
690
-
Ith
A
10
mm
2
Nm
Enclosed Isolators
Technical Data
Auxiliary Contacts Data supplied against tests to IEC/BS EN 60947-5-1 Application
Rated insulation voltage Rated thermal current
110V
8
220-240V
Rated operational current (AC15)
380-400V
Ie
A
660-690V
8 3 1
Max. conductor size
-
-
mm2
1.5
Tightening torque
-
-
Nm
0.6
...products for the real world
Terminal Markings O-I (900 indexing)
2(T1)
4(T2)
6(T3)
1
4
5
8
9
12
1
4
2 & 3 Pole
2
3
6
7
10
11
6 Pole
www.craigandderricott.com
2
5
8
9
12
6
13 16
10
Pole 4
5(L3)
Pole 3
3(L2)
Pole 1
1(L1)
I-O-II (900 indexing)
Pole 2
O-I (900 indexing)
14
C/O (4 pole shown) Page
12
Hinged Door Sheet Steel Enclosed Isolators
General Description
Supplied in ‘hinged door powder coated sheet steel and stainless steel enclosures these IP65 sealed assemblies are eminently suitable for most industrial indoor or outdoor applications. Supplied as ‘Switch-Disconnectors’, all items are supplied in generously sized enclosures which helps to avoid the need for extension boxes. The design offers a choice of accessories and options to match a variety of real world applications.
Switch-Disconnectors* (O-I)
Catalogue Numbers Rating
Format
Sheet steel (Grey)
Sheet steel (Red)
Encl. Size
32A 40A
6P 6P 3P+N 3P+NL 6P 6P+2E/B 3P+N 3P+NL 3P+N 3P+NL 3P+N 3P+NL 6P+2E/B 3P+N 3P+NL 3P+N 3P+NL 3P+N 3P+NL 3P+N 3P+NL 3P+N 3P+NL 3P+N 3P+NL 3P+N 3P+NL
SDG00326 SDG00406 SDG00633N SDG00633NL SDG00636 SDG00636EB SDGC00803N SDGC00803NL SDGC01003N SDGC01003NL SDGC01253N SDGC01253NL SDGC01256EB SDGC01603N SDGC01603NL SDGC02003N SDGC02003NL SDG02503N SDG02503NL SDG04003N SDG04003NL SDG06303N SDG06303NL SDG08003N SDG08003NL SDG10003N SDG10003NL
SDR00326 SDR00406 SDR00633N SDR00633NL SDR00636 SDR00636EB SDRC00803N SDRC00803NL SDRC01003N SDRC01003NL SDRC01253N SDRC01253NL SDRC01256EB SDRC01603N SDRC01603NL SDRC02003N SDRC02003NL SDR02503N SDR02503NL SDR04003N SDR04003NL SDR06303N SDR0603NL SDR08003N SDR08003NL SDR10003N SDR10003NL
2 2
63A
80A 100A 125A 160A
Design Features • • • • • •
Safety handle - when padlocked in the ‘Off’ position, the enclosure door cannot be opened. Capable of accepting up to three padlocks in the ‘Off’ position. (‘On’ position on request). Door interlock handle can be defeated to enable emergency opening or for testing purposes. Removable gland plates on top & bottom of all enclosures. Enclosure size 2 and above isolating switches are mounted on a removable galvanised chassis plate. IP65 Sheet steel, iron phosphate pre treatment with a powder coat RAL7035 (Grey) textured finish. IP65 Stainless steel enclosures, grade 304 with a brushed finish, for severe environments are available to order, please contact our Sales team for details.
‘Stainless steel enclosures are readily available based upon customer requirements. Please contact your Local Sales Manager for further details.’
Removable gland plates are fitted to the top & bottom faces and employ ‘blind’ fixings that will maintain the IP sealing even if a gland plate fixing screw should be missed.
200A 250A 400A 630A 800A 1000A
‘N’ = switched neutral (Early make, late break) ‘NL’ = Unswitched neutral (50% rated, 100% on request) Add ‘/EB’ to include Early break auxiliary contacts (i.e. SDG00633N/EB) Add ‘/PE’ to include a multiple earth bar (i.e. SDG00633N/PE) Add ‘/10’ to allow padlocking in both the ‘Off’ & ‘On’ positions (i.e. SDG00633N/10) Add ‘/CO’ to any part number to include 1 sets of Auxiliary contacts (i.e. SDG00633N/CO) Add ‘/2CO’ to include 2 sets of Auxiliary contacts (i.e. SDG00326/2CO) (Only applies for 32A 6P, 40A 6P or 63A 6P).
Dimensions Pg 20 Multi-padlock capacity available on all handles. Page
13
1 2 1 3A 4A 5A 4A 5A 5 6 8 8 10
Spares / Accessories - Auxiliary Contacts Add-on auxiliary blocks are available for all IP65 products. All auxiliaries are supplied as 1 N/O+1 N/C pair. N/O contacts are early make, late break.
Catalogue Numbers Rating (A)
32-200
250
400-800
1000
Cat No
SAUXCO
SAUXKITB
SAUXKITC
SAUXKITD
TYPE
A
C
C
B
Technical Specification - Switch-Disconnectors Data supplied against tests to BS EN 60947-3 Application
Sym Unit
Category
Rating (A) 6P
6P
3P
6P
3P
3P
3P
6P
3P
3P
3P
3P
3P
3P
3P
32
40
63
63
80
100
125
125
160
200
250
400
630
800
1000
Rated thermal current
Ithe
A
32
40
63
63
80
100
125
125
160
200
270
500
630
720
1000
Rated insulation voltage
Ui
V
690
690
690
690
690
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
6
6
6
6
6
8
8
8
8
8
12
12
12
12
8
Up to 415V - AC21A
32
40
63
63
80
100
125
125
160
200
250*
400*
630*
800*
1000*
690V - AC21A
Rated impulse voltage
Rated operational current (AC)
Rated operational current (DC) (/poles in series)
Uimp kV
Ie
Ie
A
32
40
63
-
80
100
125
125
160
200
250
400
630
800
1000
Up to 415V - AC22A
-
-
-
-
80
100
125
125
160
200
250*
400*
630*
800*
1000*
690V - AC22A
-
-
-
-
80
100
125
125
160
160
250
400
630
800
-
Up to 415V - AC23A
29
29
48
-
63
105
111
111
132
200*
250*
400*
630*
720*
-
690V - AC23A
17
17
33
-
33
53
57
57
57
57
250
350
350
350
-
Up to 48V - DC21A
32/1
40/1
63/1
-
80/1
-
-
-
-
-
250/2
400/2
630/1
800/1
1000/1
220V - DC21A
32/3
40/3
63/4
-
80/4
-
-
-
-
-
250/2
400/2
630/2
800/2
1000/3
-
-
-
-
-
-
-
-
-
-
250/2
400/1
630/1
800/1
-
Up to 48V - DC22A
A
220V - DC22A
-
-
-
-
-
-
-
-
-
-
250/2
400/2
630/2
800/2
-
Up to 48V - DC23A
-
-
-
-
-
-
-
-
-
-
250/2
400/1
630/1
800/1
-
220V - DC23A
-
-
-
-
-
-
-
-
-
-
250/2
400/2
630/2
630/2
-
400/415V - AC23A
15
15
25
25
30
59
63
63
75
75
132
200
315
355
400
690V - AC23A
15
15
30
30
30
51
55
55
55
55
200
315
355
355
-
kA Peak value
1.4
1.4
2.9
-
3.0
3.7
4.0
4.0
5.0
5.0
35
65
80
80
105
kA rms value
0.6
0.6
1.3
1.3
1.4
2.6
2.8
2.8
3.0
3.0
8
17
17
17
50
Rated operational Pe power
kW
Short circuit making capacity
Icm
Short circuit withstand (1sec)
Icw
Min. mechanical endurance
-
Operations (103)
250
250
250
-
250
50
50
50
50
50
16
10
10
10
6
Min. electrical endurance
-
415V - at 0.65 pf
-
-
-
-
-
-
-
-
-
-
1,000
1,000
500
500
500
Connecting capacity
Enclosed Isolators
Hinged Door Sheet Steel
Terminal type
mm Min/Max 2
mm Stud/Cu palm width Nm Tightening torque
2.5/10 2.5/10 2.5/25 2.5/25
-/25
-/70
-/70
-/70
-/70
-/95
-
-
-
-
-
-
-
-
-
8x25
10x30
10x30
12x40
12x40
12x60
1.2
1.2
1.3
1.3
2
2
2
2
2
12
25
25
40
40
40
Dimensions Pg 20
www.craigandderricott.com
Page
14
Enclosed Isolators
Fire Rated General Description
Craig and Derricott have been supplying isolation equipment for the Ventilation Industry for more than 15 years. The F400 Fire Rated product is designed specifically for installations where the supply must be maintained for 2 hours at 400°C. The use of this switchgear range is to maintain power to vital equipment such as smoke extraction / ventilation fans allowing the safe evacuation of businesses, carparks and public areas. These switch-disconnectors are installed near to the extraction fan for isolation purposes, and has been tested in conjunction with the fan equipment to meet the stringent thermal requirements of BSEN 12101-3. All enclosures come standard with padlocking in both ‘Off’ and ‘On’. The F300 Fire Rated product is designed for installations where the supply must be maintained for 1 hour at 300°C.
Catalogue Numbers Rating
20A
20A
32A
63A
125A
160A
200A
250A
400A
* Enclosure sizes from the Standard ‘Hinged Door’ range - see page 20. Dimensions Pg 21
Page
15
630A
Assembly Form (IP65)
Catalogue No. (Finished Red)
2P 3P Lid mounted 3P+2EB Aux in sheet steel 3P+N enclosure 4P 6P 2P 3P Lid mounted 3P+2EB Aux in die-cast aluminium 3P+N enclosure 4P 6P 2P 3P 3P+2EB Aux Lid mounted 3P+N in die-cast aluminium 4P enclosure 6P 6P+2EB Aux 8P 2P 3P 3P+2EB Aux 3P+N 4P 6P 6P+2EB Aux 2P 3P 3P+2EB Aux 3P+N 4P 6P 6P+2EB Aux 3P
FSDMR0202 FSDMR0203 FSDMR0203EB FSDMR0203N FSDMR0204 FSDMR0206 FSDDR0202 FSDDR0203 FSDDR0203EB FSDDR0203N FSDDR0204 FSDDR0206 FSDDR0322 FSDDR0323 FSDDR0323EB FSDDR0323N FSDDR0324 FSDDR0326 FSDDR0326EB FSDDR0328 FSDMR0632 FSDMR0633 FSDMR0633EB FSDMR0633N FSDMR0634 FSDMR0636 FSDMR0636EB
Format
4P 6P Base 6P+2EB Aux mounted in 3P hinged door 3P+2EB Aux sheet steel enclosure 4P 6P 6P+2EB Aux 3P 3P+2EB Aux 4P 6P 6P+2EB Aux 3P 3P+2EB Aux 4P 6P 6P+2EB Aux 3P 3P+2EB Aux 4P 6P 6P+2EB Aux
‘N’ = Switched neutral (Early make, late break) ‘EB’ = Early break auxiliary contacts
Temp. Class.
Encl. size (IP65)
F400
A
F400
E B
F400
B
F400
C
F400
D
RS1BD11/HPHT RS1BT21/HPHT RS1BT31/2EB/HPHT RS1BT21/HPHT/NL RS1BQ21HPHT RS1BY31/HPHT RS1BY41/2EB/HPHT
FSDMR1603 FSDMR1604 FSDMR1606 FSDMR1606EB FSDMR2003 FSDMR2003EB FSDMR2004 FSDMR2006 FSDMR2006EB FSDMR2503 FSDMR2503EB FSDMR2504 FSDMR2506 FSDMR2506EB FSDMR4003 FSDMR4003EB FSDMR4004 FSDMR4006 FSDMR4006EB FSDMR6303 FSDMR6303EB FSDMR6304 FSDMR6306 FSMDR6306EB
4* F300 5*
F300
5* 7*
F300
5* 7*
F300
6* 9*
F300
8* 9*
Specification Within BS EN 12101-3: 2003 (Smoke and heat controls) there are different classes of duty which define a specific temperature gradient, upper temperature limit and time period. F300 300oC for 60 min. F400 400oC for 120 min.
Enclosed Isolators
Fire Rated
Technical Specification Data supplied against tests to IEC/BS EN 60947-3 Application Rated thermal current Rated insulation voltage Rated impulse voltage
Rated operational power (3 phase AC) Short circuit withstand (1 sec) Conditional Short Circuit Current
Sym.
Unit
20A
32A
63A
125A
160A
200A
250A
400A
630A
Ithe
A
20
32
63
125
160
200
250
400
630
Ui
V
690
690
690
690
750
1000
1000
1000
1000
Uimp
kV
6.0
6.0
6.0
6.0
12.0
12.0
12.0
12.0
12.0
Ie / Pe
A/kW
415V - AC23A
20/9.5
32/15
40/18.5
100/55
100/45
200/110
250/132
400/200
630/315
690V - AC23B
20/9.5
20/9.5
20/9.5
-
63/45
200/170
250/200
350/315
350/355
660V - AC23B Icw Fuse gG
kA
RMS value
415V kA/ Fuse(A) 690V -
Recommended connecting capacity
Category
mm
-
-
-
30/22
-
-
-
-
-
-
-
-
1.5
5.0
8.0
8.0
17.0
17.0
50/32
50/32
50/63
50/200
50/160
50/200
50/250
40/32
40/32
40/63
50/63
50/63
50/200
50/250
50/400
100/630
-
Terminal type Flexible cable
≤ 4.0
6
16
50
95
95
120
2/150
2/185
mm2
Rigid cable
≤ 4.0
10
25
50
95
95
120
2/150
2/185
Nm
Tightening torque
1.2
1.2
3.0
12.0
8.0
8.0
8.0
17.0
21.0
2
Dimensions Pg 21
www.craigandderricott.com
Page
16
LUL ‘Section 12’ Equipment Enclosed Isolators
Background
London Underground Limited (LUL) Section 12 Equipment Following the London Kings Cross fire of 1987, the resulting Fennell enquiry prompted the introduction of additional fire precautions for ‘Sub-surface Railway Stations’. These additional requirements were introduced under section 12 of the Fire Precautions Act 1971, and since then have been known simply as Section 12 regs. The forensic report on the fire sited several instances of a ‘flash over’ effect caused by materials and paint finishes being ignitable. Exacerbating the conditions underground were toxic fumes given off by certain materials being excessively heated. Although the new regulations dealt with all aspects of fire prevention such as the removal of wooden escalators, the installation of heat detectors, improved staff training etc, as far as actual equipment supplied for underground use, the overriding emphasis was on materials and paint finishes. With this isolation range, the overall consideration has been to meet, and where possible exceed, the Section 12 requirements. This has been achieved by the careful selection of individual component materials and the use of only recognised and approved paint finishes. * Replaced by the current regulations:- ‘The Fire Precautions (Sub-surface Railway Stations’ (England) Regulations 2009.
Die-Cast Enclosures Design Features
Switch-Disconnectors (O-I)
Catalogue Numbers Rating
25A
40A
Format
2P 3P 3P+2EB Aux 4P 6P 6P+2EB Aux 2P 3P 3P+2EB Aux 4P 6P 6P+2EB Aux
• Paint Finishes:-
Interior Switch product range
Catalogue Nos.
GN25 GN25 GN25 GN25 GN25 GN25 R32 R32 R32 R32 R32 R32
Grey
Red
DCG252LUL10 DCG253LUL10 DCG253EBLUL10 DCG254LUL10 DCG256LUL10 DCG256EBLUL10 DCG402LUL10 DCG403LUL10 DCG403EBLUL10 DCG404LUL10 DCG406LUL10 DCG406EBLUL10
DCR252LUL10 DCR253LUL10 DCR253EBLUL10 DCR254LUL10 DCR256LUL10 DCR256EBLUL10 DCR402LUL10 DCR403LUL10 DCR403EBLUL10 DCR404LUL10 DCR406LUL10 DCR406EBLUL10
‘EB’ = Early break auxiliary contacts
To order a neutral link please include in the catalogue ref. as follows:Example - 3 Pole + Neutral Link - DCG403NLLUL10
Technical Specification
Rated thermal current Rated operational power (3 phase AC)
Dimensions Pg 22
Page
17
Sym
Unit
Ithe
A
-
25A
40A
kW
380/440V AC23A
11.0
15.0
-
A (IP65)
B (IP65)
LU1-085 Compliant Paint Finish Colour - Light Grey (RAL7035) Traffic Red (RAL3020)
• Captive lid fixing screws with a security head. • Enclosure material - Aluminium (LM6) • Sealing to IP65. • Supplied with pre-finished steel mounting brackets. • Padlocking cast lever handle. • Positive break contacts. • Earthing points on both lid and base plus external earth stud. • Padlocking in both ‘Off’ & ‘On’. • Second product label supplied loose for fitting by the contractor where the original label may be obscured. • Labels - Engraved traffolyte labels in various colours can be supplied attached to the side of the enclosure or supplied loose for fitting adjacent to the isolator. LUL Product Registration Certificate Nos. 638 & 639 Status - Authorised for use.
Electrical ratings to BS EN 60947-3 Application
Enclosure Size
Category
Rating
LUL ‘Section 12’ Equipment
Design Features
Switch-Disconnectors (O-I)
• Lid mounted switch interiors. • Captive lid fixing screws with a security head. • Enclosure material - 18 gauge stainless steel grade 304. • Finish - Natural - Brushed (Non glare) • Sealing to IP65. • Supplied with stainless steel mounting brackets. • Padlocking cast lever handle. • Positive break contacts. • Earthing points on both lid & base plus external earth stud. • Padlocking in both ‘Off’ & ‘On’. • Second product label supplied loose for fitting by the contractor where the original label may be obscured. • Labels - Engraved traffolyte labels in various colours can be supplied attached to the side of the enclosure or supplied loose for fitting adjacent to the isolator. LUL Product Registration Certificate Nos. 638 & 639 Status - Authorised for use.
Catalogue Numbers
25A
40A
Format
2P 3P 3P+2EB Aux 4P 6P 6P+2EB Aux 2P 3P 3P+2EB Aux 4P 6P 6P+2EB Aux
Interior Switch product range
Catalogue Nos. Stainless steel
GN25 GN25 GN25 GN25 GN25 GN25 GN40 GN40 GN40 GN40 GN40 GN40
DS252LUL10 DS253LUL10 DS253EBLUL10 DS254LUL10 DS256LUL10 DS256EBLUL10 DS402LUL10 DS403LUL10 DS403EBLUL10 DS404LUL10 DS406LUL10 DS406EBLUL10
Catalogue Nos. Grey
Red
Enclosure Size
40A
DCG0403LUL
DCR0403LUL
1
63A
DCG0633LUL
DCR0633LUL
1
80A
DCG0803LUL
DCR0803LUL
2
100A
DCG1003LUL
DCR1003LUL
2
125A
DCG1253LUL
DCR1253LUL
2A
160A
DCG1603LUL
DCR1603LUL
2A
200A
DCG2003LUL
DCR2003LUL
3
250A
DCG2503LUL
DCR2503LUL
3
315A
DCG3153LUL
DCR3153LUL
4
400A
DCG4003LUL
DCR4003LUL
4
Rating
Design Features
Switch-Disconnectors (O-I)
Rating
Catalogue Numbers
Enclosure Size
C (IP65)
• • • • • •
Ratings 40A - 400A (3P + switched N).
Grey or Traffic Red LU1-085 Compliant Paint Finish. All metal padlocking handle. Can be supplied lockable in both ‘Off’ & ‘On’. Removable top & bottom gland plates. Sealing to IP65.
LUL Product Registration Certificate No. 3062 Status - Authorised for use.
Technical Specification D (IP65)
Electrical ratings to BS EN 60947-3 Rating
Rated Thermal Current Ith
Rated operational Power Pe kW (400V - AC23A)
‘EB’ = Early break auxiliary contacts
40A
40A
18.5
To order a neutral link please include in the catalogue ref. as follows:- Example - 3 Pole + Neutral Link - DS253NLLUL10
63A
63A
25
80A
80A
40
100A
100A
40
125A
125A
63
160A
160A
80
200A
200A
100
250A
250A
132
315A
315A
160
400A
400A
220
Technical Specification Electrical ratings to BS EN 60947-3 Application Rated thermal current Rated operational power(3 phase AC)
Enclosed Isolators
Hinged Door Enclosures
Stainless Steel Enclosures
Sym
Unit
Category
Rating
Ithe
A
-
25A
40A
-
kW
380/440V AC23A
11.0
18.5
www.craigandderricott.com
Dimensions Pg 22
Page
18
Dimensions & Fixings
4 x Fixings (Ø)
Size A Size B Size C Size D
Overall Dims. H W D 135 100 95 175 130 115 255 180 125 255 180 175
30
‘D’
1
Sizes A&B
Fixing details F1 F2 85 98.5 115 135 163.5 238.5 163.5 238.5
‘W’ ‘F1’
40
‘D’
Sizes C&D
‘H’ ‘F2’
‘W’ F1
‘H’ F2
Enclosed Isolators
Plastic Enclosed
4 x Fixings (Ø)
Ø 5.5 5.5 4.5 4.5
Mild Steel & Stainless Steel Enclosed *
†
†
††
Employing external mounting straps EFA or EFB. 62 when using Defeatable Door Interlock Handle Overall Dims.
4 x Internal Fixings (Ø)
4 x External Fixings (ØØ)
*
Stainless steel enclosures are supplied without ‘raised dimples’ to allow flush mounting.
Internal Fixings
External Fixings † †
H
W
D
F1
F2
Ø
F3
F4
F5
ØØ
Size A
135
100
80
51
86
5.5
126
140
16
6.35
Size B
175
130
100
81
126
5.5
155
178
16
6.35
Sloping Roof Stainless Steel Enclosed
Overall Dims.
Ø
Internal Fixings
Size A
Size B
H1
200
240
H2
165
200
W
135
185
D
80
100
D2
127
147
FCH
70
90
FCV
110
130
Ø
5.5
5.5
Flush Mounting Stainless Steel 125 sq 100 sq
75
40
175 sq 150 sq
* Size B
Size A
* = 75
Size C
* = 100
Page
19
40
Dimensions & Fixings Size A
Size B Entries style ‘X’
Entries style ‘X’
2 Holes M25 x 1.5 Through
Three entries on bottom face of enclosure only.
Entries style ‘Y’
Entries style ‘Y’
Entries as shown repeated on top face of enclosure.
Entries on top and bottom of enclosure as shown.
Enclosed Isolators
Die-Cast Enclosed
Hinged Door Sheet Steel F
G (CRS)
E
ØØ
J (CRS)
Gland plate thickness (K) Ø 4 off internal mounting holes
Handle projection
A H
C
D
External Mounting Feet (Four per set) Case Sizes 1 & 2 Cat No. SEFL1/KIT Case Sizes 3 - 7 Cat No. SEFL2/KIT Case Sizes 8 - 10 Cat No. SEFL3/KIT
B W Enclosure Sizes
Dim
1
2
3
3A
4
4A
5
5A
6
7
8
10
H
250
250
400
350
500
400
550
550
750
750
900
1000
W
250
300
350
300
350
300
450
400
450
600
600
750
D
100
200
200
175
200
175
250
175
275
300
300
300
A
170
170
320
270
420
320
470
470
670
670
820
920
B
170
220
270
220
270
220
370
320
370
520
520
670
C
40
67
67
67
67
67
67
67
67
67
67
67
K
1.5
1.5
1.5
2.0
1.5
2.0
2.0
2.0
2.0
2.5
2.5
2.5
Ø
6.5
6.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
10.5
10.5
E
35
35
35
35
35
35
35
35
35
35
35
35
F
53
58
58
58
58
58
58
58
58
58
58
58
G
18
18
13
13
13
13
13
13
13
13
13
13
J
58
58
58
58
58
58
58
58
58
58
58
58
ØØ
6.5
6.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
10.5
10.5
External Feet
Material IP65 Sheet steel, iron phosphate pre treatment with a powder coat textured finish IP65 Stainless Steel, grade 304 with a brushed finished Hinges Metal with quick release pins. Door Locks All metal locks supplied with one key per enclosure. Enclosures 1 & 2 IP65 - 1 lock Enclosures 3 - 9 IP65 - 2 locks Enclosures 10 IP65 - 3 locks Gland plates All enclosures are supplied with a removable gland plate on top & bottom faces finished to match the enclosure. Chassis plate Above enclosure size 1, all assemblies have the switching element mounted on a removable chassis plate. Matl. - 2mm zinc plated steel.
www.craigandderricott.com
Page
20
Enclosed Isolators
Dimensions & Fixings
Page
21
Fire Rated (High Temperature)
Size A
Size B
Size C
Size D
Size E
Dimensions & Fixings Overall Depth 140
148 CRS
90 CRS
110 SQ
25A Die cast Aluminium Enclosure (A)
40A Die cast Aluminium Enclosure (B)
Enclosed Isolators
LUL ‘Section 12’ Equipment
4 x M6 fixings
4 x M6 fixings
25A Stainless Steel Enclosure (C)
40A Stainless Steel Enclosure (D)
Hinged Door
CASTELL LOCK POSITION
Enclosure finished with an approved paint system and sealed to IP65
www.craigandderricott.com
Page
22
Enclosed Isolators
Exe IECEx/ATEX Zone 1 & 2 Isolators General Description
Craig & Derricott has been associated with the design and manufacture of Ex products for more than 30 years. The ‘EXZ1’ range of enclosed switch-disconnectors are supplied in ‘EXe’ enclosures manufactured from glass reinforced polyester sealing to IP65 ensuring the product will withstand being installed in the harshest of industrial environments. The operating handles are available in Red/Yellow or Black and can be padlocked in the ‘Off’ position. All lids are mechanically interlocked with the isolating switch and are removable in the ‘On’ position only. Available in ratings from 20A - 150A the isolating switch interiors are supplied in either 3 or 4 pole formats complete with 1 N/O (Early break) & 1 N/C (Late make) auxiliary contacts.
Catalogue Numbers Rating
Format
3P+Aux 20A 4P+Aux 3P+Aux 32A 4P+Aux 3P+Aux 63A 4P+Aux 150A
3P+Aux
Handle Colour
Cat. No.
Red/Yellow Black Red/Yellow Black Red/Yellow Black Red/Yellow Black Red/Yellow Black Red/Yellow Black Red/Yellow Black
EXZ1SDR0203 EXZ1SDB0203 EXZ1SDR0204 EXZ1SDB0204 EXZ1SDR0323 EXZ1SDB0323 EXZ1SDR0324 EXZ1SDB0324 EXZ1SDR0633 EXZ1SDB0633 EXZ1SDR0634 EXZ1SDB0634 EXZ1SDR1503 EXZ1SDB1503
Enclosure Size
A
B
C
D
Aux - 1 N/O (Early break) & 1 N/C (Late make)
Natural brass Earthing Plate shown with glands fitted (Glands not supplied)
Certification
All items have been approved with ‘ATEX’ (Sira 13ATEX3205X) and ‘IECEx’ (IECEx SIR 13.0076X) certicates for use in Zones 1 & 2. The equipment is designed and tested to comply with the following:-
Dimensions Pg 25
Page
23
• EN 60079-0 Electrical Atmospheres, Part 0 : Equipment - General requirements. • EN 60079-1 Electrical Atmospheres, Part 1 : Equipment protection by flameproof enclosures ‘d’. • EN 60079-7 Electrical Atmospheres, Part 7 : Equipment protection by increased safety ‘e’. • EN 60947-1 Low-Voltage switch gear and controlgear - Part 1: general rules. • EN 60947-3 Low-Voltage switch gear and controlgear - Part 3: switches, disconnectors, switch-disconnectors and fuse combination units. • EN 60529 Degrees of protection provided by enclosures. (IP Code)
Earthing Plates
To enable armoured cables to be earth bonded within the insulated enclosure a selection of pre-drilled earthing plates are available for each enclosure size. Supplied in either natural or electroless Nickel plated brass.
Enclosure Size A
B
C
D
Brass (Natural)
EXZ1EPA1
EXZ1EPB1
EXZ1EPC1
EXZ1EPD1
Brass (Electroless Nickel Plated
EXZ1EPA2
EXZ1EPB2
EXZ1EPC2
EXZ1EPD2
M4
M5
M6
M8
Connection Terminal
Enclosed Isolators
Exe IECEx/ATEX Zone 1 & 2 Isolators
Technical Specification - Switch-Disconnector Main Contacts Application
Sym.
Unit
Rated thermal current
Ithe
A
Rated insulation voltage
Ui
V
Main Contacts
Category
Aux. Contacts
20A
32A
63A
150A
20
32
63
150
Category
Aux. 10
690
690
690
690
AC3 (230V)
20
32
63
150
AC15 (250V)
10
AC3 (400V)
20
32
63
150
AC15 (400V)
8
AC3 (500V)
20
32
63
150
DC13 (24V)
8
AC3 (690V)
16
32
63
125
DC13 250V)
1
Terminal Capacity
-
2x6mm
2x16mm
Tightening Torque (Nm)
-
1.2
2.5
Rated current
-
Terminal Type
A
2
2
2x35mm
2
3
2x95mm 6
690
2
2x6 1.2
-
Equipment Marking 20A
II 2 G Ex e d IIC T4 Gb - (-40oC ≤ Ta ≤ +40oC)
32A
II 2 G Ex e d IIC T6 Gb - (-40oC ≤ Ta ≤ +40oC)
63A
II 2 G Ex e d IIC T6 Gb - (-40oC ≤ Ta ≤ +40oC)
150A
II 2 G Ex e d IIC T5 Gb - (-40oC ≤ Ta ≤ +30oC)
Key to Marking Specific marking for Explosion protection
Ex e d IIC T6 Gb Equipment protection level Temperature class Gas group Protection method - Increased safety ‘e’ Flameproof ‘d’ Explosion protection
II Equipment group 2 Equipment category G Environment e.g. Gas
Dimensions Pg 25
www.craigandderricott.com
Page
24
Enclosed Isolators
Exe IECEx/ATEX Zone 1 & 2 Dimensions
Enclosure A
Enclosure C
Page
25
Enclosure B
Enclosure D
General Description
A range of Switch-Disconnectors housed in heavy duty cast enclosures - ATEX certified for use in Cat II, Zones 1, 2, 21 & 22 environments. Certifications and Approvals
Ex d II 2 GD IIB T6 ITS 09 ATEX 16433X, ITS 09 ATEX 16436U EN 60079-0, EN 60079-1, EN 61241-0 & EN 61241-1 -20oC to +40oC IP65
• Certification Code • Certification No. • Certification standard • Operating temperature • Ingress Protection
High quality heavy duty cast enclosures are used throughout the range. (Cast Iron 16A - 63A, Cast Aluminium 80A - 250A). The enclosures are supplied with large cable entries which can be fitted with approved reducers to suit individual cable requirements. All load switching interiors are supplied as either 3P+N (switched neutral) or 6P and have AC23A ratings to BS EN 60947-3. Auxiliary contacts are available for applications such as SCADA packages. Operating handles are capable of accepting up to three padlocks in the ‘Off’ position.
Enclosed Isolators
Exd ATEX Zone 1/21 & 2/22 Isolators
Finish - RAL 7035 Two pack grey epoxy coating over etching primer.
Technical Specification
Rating (A) 16A
20A
25A
63A
80A
100A
125A
Application
Sym.
Unit
Category
3P
6P
3P
6P
40A 3P
3P
3P
3P
3P
250A 3P
Enclosure
-
-
-
G21
G21
G21
G22
G22
G22
G24
G25
G25
G28
Rated thermal current
Ithe
A
-
16
20
25
40
40
63
80
100
125
250
Rated insulation voltage
Ui
V
-
690
690
690
690
690
690
690
750
750
1000
Rated impulse voltage
Uimp
kV
Rated opertaional power (3 phase AC)
Pe
Rated short time withstand current (1 sec)
Icw
A
Max. fuse size for short circuit protection (gG characteristic)
In
A
kW
-
6.0
6.0
6.0
6.0
6.0
6.0
6.0
8.0
8.0
12.0
7.5
7.5
11.0
18.5
18.5
25.0
30.0
37.0
45.0
132.0
500V - AC23
9.0
7.5
15.0
15.0
22.0
30.0
37.0
-
-
-
690V - AC23
9.0
7.5
15.0
15.0
22.0
30.0
30.0
37.0
45.0
200.0
400
250
500
800
1100
1300
1400
2500
2500
8000
10kA
32
20
35
40
80
80
80
-
-
-
25kA
31
16
32
35
63
63
63
-
-
-
50kA
32
-
32
-
63
63
63
-
-
-
Terminal type
mm
Flexible cable
6.0
2x2.5
6.0
2x6.0
16.0
16.0
16.0
-
-
-
mm2
Rigid cable
10.0
2x2.5
10.0
2x10
25.0
25.0
25.0
-
-
-
mm
Stud Cu palm width
-
-
-
-
-
-
-
8x20
8x20
10x30
Nm
Tightening torque
1.2
1.2
1.2
1.2
1.2
1.2
1.2
6.0
8.0
30-44
2
Connecting capacity
380/440V - AC23
Dimensions Pg 27
www.craigandderricott.com
Page
26
Enclosed Isolators
Exd ATEX Zone 1/21 & 2/22 Isolators Catalogue Numbers Current Rating (A)
Format
Catalogue No.
Enclosure Ref.
Supplied Entries*
External Earth
16 25 20 40 40 63 80 100 125 160 200 250
3P+N+2E/B 3P+N+2E/B 6P + 2E/B 3P+N+2E/B 6P + 2E/B 3P+N+2E/B 3P+N+2E/B 3P+N+2E/B 3P+N+2E/B 3P+N+2E/B 3P+N+2E/B 3P+N+2E/B
DGC0164EBZ1 DGC0254EBZ1 DGC0206EBZ1 DGC0404EBZ1 DGC0406EBZ1 DGC0634EBZ1 DGC0804EBZ1 DGC1004EBZ1 DGC1254EBZ1 DGC1604EBZ1 DGC2004EBZ1 DGC2504EBZ1
G21 G21 G21 G22 G22 G22 G24 G25 G25 G25 G28 G28
3 x M20 4 x M20 2 x M25 + 1 x M20 2 x M25 + 1 x M20 2 x M25 + 1 x M20 2 x M25 + 1 x M20 3 x M32 + 1 x M20 3 x M32 + 1 x M20 3 x M40 + 1 x M20 2 x M32 + 1 x M20 3 x M50 + 1 x M20 3 x M50 + 1 x M20
M6 M6 M6 M8 M8 M8 M8 M8 M8 M8 M10 M10
‘N’ = Switched neutral (Early make, late break) ‘EB’ = Early break auxiliary contacts * Other entry configurations available on request.
Dimensions
N.B. Enclosures can be close coupled at either end (To special order)
A Enclosure Width D B Enclosure Height E C Enclosure Depth F G
Fixing Centre Height Fixing Centre Width Fixing Hole Diameter Internal Depth from Base Plate
Dimensions
Page
27
Enclosure
Material
A
B
C
D
E
F
G
Weight (Kg)
G21
Fe
180
155
145
130
195
7.0
100
9
G22
Fe
205
220
156
160
230
9.0
117
19
G24
Al
321
361
228
291
320
11.0
179
21
G25
Al
366
406
218
250
370
11.0
177
25
G28
Al
586
690
294
480
580
14.0
216
96
Fire Rated General Description
Enclosed Isolators
To complement the F300 / F400 fire rated switch-disconnector range described on page 15-16, Craig and Derricott have introduced the F200 Fire Rated isolator for installations where the supply must be maintained for 2 hours at 200°C. The use of this product is to maintain power to vital equipment such as smoke extraction / ventilation fans allowing the safe evacuation of businesses, carparks and public areas. These switch-disconnectors are installed near to the extraction fan for isolation purposes, and has been tested in conjunction with the fan equipment to meet the stringent thermal requirements of BSEN 12101-3. These base mounted enclosures come standard in a red (RAL 3020) colour finish, with padlocking in both ‘Off’ and ‘On’ position.
Die-cast aluminium enclosures - Sealing to IP66
Hinged door enclosures - Sealing to IP65
Catalogue Numbers Rating
20A
25A
32A
40A
63A
Format
Interior Switch Product Range
6P GX20 6P+2EB Aux 2P 3P 3P+2EB Aux CS25 3P+N 3P+NL 2P 3P 3P+2EB Aux CS32 3P+N 3P+NL 2P 3P 3P+2EB Aux CS40R 3P+N 3P+NL 6P GX40 6P+2EB Aux 2P 3P 3P+2EB Aux CS40 3P+N 3P+NL
Catalogue No. (Finished Red)
F2SDDR206X F2SDDR206EBX F2SDDR252X F2SDDR253X F2SDDR253EBX F2SDDR253NX F2SDDR253NLX F2SDDR322X F2SDDR323X F2SDDR323EBX F2SDDR323NX F2SDDR323NLX F2SDDR402X F2SDDR403X F2SDDR403EBX F2SDDR403NX F2SDDR403NLX F2SDDR406X F2SDDR406EBX F2SDDR402TX F2SDDR403TX F2SDDR403EBTX F2SDDR403NTX F2SDDR403NLTX
2P
F2SDDR632X
3P
F2SDDR633X
3P+2EB Aux 3P+N
CS63
3P+NL 80A
Catalogue Numbers
3P 3P+N 3P+NL
F2SDDR633EBX F2SDDR633NX
Temp. Class.
Encl. size
Rating
F200
A
63A 80A
F200
A
100A 125A
F200
A
160A 200A
F200
A
Format
3P+N 3P+NL 3P+N 3P+NL 3P+N 3P+NL 3P+N 3P+NL 3P+N 3P+NL 3P+N 3P+NL
F2SDDR803X F2SDDR803NX
CS63 CS80 CS100 CS125 CS160 CS200
Catalogue No. (Finished Red)
F2SDRC00633N F2SDRC00633NL F2SDRC00803N F2SDRC00803NL F2SDRC01003N F2SDRC01003NL F2SDRC01253N F2SDRC01253NL F2SDRC01603N F2SDRC01603NL F2SDRC02003N F2SDRC02003NL
Temp. Class.
Encl. size
F200
1
F200
1
F200
3A
F200
4A
F200
4A
F200
5A
‘N’ = Switched neutral (Early make, late break) ‘NL’ = Unswitched neutral ‘EB’ = Early break auxiliary contacts ‘T’ = Increased terminal capacity ‘X’ = Bottom cable entries only
For top and bottom cable entires, please replace ‘X’ with ‘Y’ in the catalogue number i.e. F2SDDR206Y
F200
B
F200
B
Technical Data Pg 12+14
F2SDDR633NLX CS80
Interior Switch Product Range
F200
B
F2SDDR803NLX
www.craigandderricott.com
Dimensions Pg 20
Page
28
Compact Panel Isolators 25A - 200A General Description
Panel Isolators
Craig & Derricott has ranges of compact control panel isolation equipment for panel mounting ranging from 25A to 200A. All come supplied with operating handle and a standard length shaft. A compact range of switch-disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block. Features
• • • •
Catalogue Numbers Current Rating (A)
32A
40A
63A
80A
100A
125A
160A
Dimensions Pg 34
Page
29
63A 3P assembly complete with standard shaft and handle assembly.
The catalogue numbers below include: • On-load AC23A switch-disconnector. • 100mm standard length shaft assembly. • IP65 minimum door interlock handle.(Black) • Terminal covers (A2 frame size only).
25A
Technical Data Pg 33
IP2X terminal protection. Door interlock handles with override facility. DIN rail or base mounting. Add-on auxiliary/neutral blocks.
200A
Format
Catalogue Number
2P 3P 3P+N 3P+NL 6P 3P 3P+N 3P+NL 6P 3P 3P+N 3P+NL 6P 3P 3P+N 3P+NL 6P 3P 3P+N 3P+NL 6P 3P 3P+N 3P+NL 6P 3P 3P+N 3P+NL 6P 6P+2EB Aux 3P 3P+N 3P+NL 6P 6P+2EB Aux 3P 6P
SD00252B SD00253B SD00253NB SD00253NLB SD00256B SD00323B SD00323NB SD00323NLB SD00326B SD00403B SD00403NB SD00403NLB SD00406B SD00633B SD00633NB SD00633NLB SD00636B SD00803B SD00803NB SD00803NLB SD00806B SDC01003B SDC01003NB SDC01003NLB SDC01006B SDC01253B SDC01253NB SDC01253NLB SDC01256B SDC01256EB SDC01603B SDC01603NB SDC01603NLB SDC01606B SDC01606EB SDC02003B/ETC SDC02006B/ETC
Frame Size
‘B’ = Black Handle. For Red Handle, replace B with R in the catalogue number. i.e. SD00253R ‘NB’ = Switched neutral (Early make, late break) with Black Handle “NLB” = Unswitched neutral with Black Handle “ETC” = Excluding Terminal Covers
A0
Extended shafts
Both the standard 100mm shaft and the longer version as shown below can easily be adjusted to suit specific panel depths. The correct dimension to be removed (X) can easily be determined using the dimensions shown on page 34-35.
Catalogue Numbers A0
Shaft length ‘L’ 200mm 200mm
Frame size AO & A1 A2 & A3
Shaft (mm2) 6 8
Catalogue No. SSH2 SSH17
A0
A1 The standard 100mm option shown. A1
A2 Handle assembly supplied with the ‘A0’ & ‘A1’ frame sizes (SDH1/BLK). A2
A2
A3
Handle assembly supplied with the ‘A2’ & ‘A3’ frame sizes (SDH3/BLK). Includes facility.
emergency
override
Compact Panel Isolators 25A - 200A Accessories All of the accessories listed below can be retro-fitted. One block can be fitted either side of the main assembly on all of the 3 pole switchdisconnector interiors.
Catalogue Numbers Description
Cat. No.
Auxiliary Contact - 2 Early Break
SAUX2EB
Auxiliary Contact - 1 N/O + 1 N/C
SAUXCO
25A Neutral (Unswitched)
SNL25
40A Neutral (Unswitched)
SNL40
63A Neutral (Unswitched)
SNL63
80A Neutral (Unswitched)
SNL80
100A Neutral (Unswitched)
SNL100
125A Neutral (Unswitched)
SNL125
160A Neutral (Unswitched)
SNL160
200A Neutral (Unswitched)
SNL200
25A Neutral (Switched)
SSP25
40A Neutral (Switched)
SSP40
63A Neutral (Switched)
SSP63
80A Neutral (Switched)
SSP80
100A Neutral (Switched)
SSP100
125A Neutral (Switched)
SSP125
160A Neutral (Switched)
SSP160
200A Neutral (Switched)
SSP200
Neutral Link (Unswitched)
2 Early Break Auxiliary
Neutral Link (Switched)
Panel Isolators
Auxiliary Blocks
SSP63
SAUXCO 63A Switch-Disconnector fitted with Aux blocks
Typical 40A 6 pole assembly
Assembly of ‘SDH1/BLK’ handle and SSH1/2 shaft assembly
Technical Data Pg 33 Dimensions Pg 34
www.craigandderricott.com
Page
30
Standard Panel Isolators 100A - 1000A General Description
Panel Isolators
A robust range of load break switches to ensure simple installation in applications such as power distribution boards. The compact design also suits OEM’s and stand alone enclosure installations. A range of accessories extends the versatility. Features: • • • • • • •
The catalogue numbers below include: • On-load AC23A switch-disconnector. • 200mm standard length shaft assembly. • IP65 door interlock handle.(Black).
100A
125A
160A
200A
250A
315A
400A
630A
800A 1000A
Dimensions Pg 35
Page
31
Alternative shafts
Catalogue Numbers Current Rating (A)
Technical Data Pg 33
On-load AC23A ratings. Four frame sizes covering 100A - 1000A. Direct lug connections onto plated Copper palms. Windows for contact inspection Supplied as either 3 or 4 pole versions. IP65 sealing door interlocking handles. Internal locking feature.
Format
Catalogue Number
3P 3P+NL 4P 3P 3P+NL 4P 3P 3P+NL 4P 3P 3P+NL 4P 6P 3P 3P+NL 4P 6P 3P 6P 3P 3P+NL 4P 6P 3P 3P+NL 4P 3P 3P+NL 4P 3P 4P
SD01003B/ETC SD01003NLB/ETC SD01004B/ETC SD01253B/ETC SD01253NLB/ETC SD01254B/ETC SD01603B/ETC SD01603NLB/ETC SD01604B/ETC SD02003B/ETC SD02003NLB/ETC SD02004B/ETC SD020006B/ETC SD02503B/ETC SD02503NLB/ETC SD02504B/ETC SD02506B/ETC SD03153B/ETC SD03156B/ETC SD04003B/ETC SD04003NLB/ETC SD04004B/ETC SD04006B/ETC SD06303B/ETC SD06303NLB/ETC SD06304B/ETC SD08003B/ETC SD08003NLB/ETC SD08004B/ETC SD10003B/ETC SD10004B/ETC
Frame Size
B1
As an alternative to the standard 200mm shaft a 400mm option is available as indicated below. The shafts are manufactured from square section steel and zinc plated. The height setting is adjusted by passing the shaft through a bush in the switch mechanism and locking it in position using two ‘cup point’ grub screw. Catalogue Numbers
B1
Shaft length ‘L’ 400mm
B1
Drive Shaft Section Max. possible enclosure depth
Load break switch current Rating 100A - 160A
200A - 250A
400 - 1000A
SSH13
SSH14
SSH15
6mm
8mm
12mm2
2
2
200mm
250
270
285
400mm
450
470
485
B2
B2
‘L’
B3
B3
B3
B3
Handle assembly supplied with the ‘B2’ frame size(SDH3BLK).
B4
‘B’ = Black Handle. For Red Handle, replace B with R in the catalogue number. i.e. SD00253R ‘NB’ = Switched neutral (Early make, late break) with Black Handle “NLB” = Unswitched neutral with Black Handle “ETC” = Excluding Terminal Covers
Handle assembly supplied with the ‘B3’ (SDH4/BLK) & ‘B4’ (SDH7/BLK) frame sizes
Standard Panel Isolators 100A - 1000A Auxiliary Contacts
Add-on auxiliary contacts are available for the 100A - 1000A range and can be selected from the table below. All auxiliary kits contain the necessary fixings and attachments to install the contact blocks which are supplied in 1 N/O + 1 N/C format. All N/O contacts are early break with respect to the main poles when switching from ‘On’ to ‘Off’.
Contact block types
Load break switch rating Rating (A)
100 - 160A
250A
400 - 800A
1000A
Catalogue No.
SAUXKITA
SAUXKITB
SAUXKITC
SAUXKITD
B
C
C
B
Block type
B
C
Panel Isolators
Accessories
Auxiliary Contacts - Data supplied against tests to BS EN 60947-1 Thermal current Rated insulation voltage Utilisation Category
Sym. Ithe Ui -
Category
AC15 DC13 Pure Resistive
Auxiliary blocks type ‘B’ 10A 660V a.c. or d.c. 6.0A at 120V, 4.0A at 250V, 2.0A at 660V 1.0A at 120V, 0.5A at 240V, 0.1A at 660V 10A
Auxiliary blocks type ‘C’ 10A 690V a.c. 4.0A at 240V 1.0A at 120V -
Dimensions Aux. contact block SDH3/4/7 Handles
Panel drilling
SDH1 Handle (A0 & A1)
Panel drilling
Handle
Shaft section
Dimension ‘Y’
Isolator Frame Sizes
SDH3
8mm
SDH4
12mm2
80mm
A2, A3, B1 & B2
146mm
SDH7
12mm2
220mm
B3 B4
2
Technical Data Pg 33 Dimensions Pg 35
www.craigandderricott.com
Page
32
Page
33
Ie
Pe
Icm
Icw
Rated operational current (DC) ( /poles in series)
Rated operational power
Short circuit making capacity
Short circuit withstand (1sec)
11 15
400/415V - AC23A
690V - AC23A
-
-
-
-
125
125 160
160
1.2
Nm Tightening torque
1.2
1.2
1.2
-
1.2
-
200
200
3.7
51
59
-
-
-
-
-
-
53
100
100
100
100
100
8
-
-
50 x 103
2.8
4.0
55
63
-
-
-
-
-
-
-
112
125
125
125
125
8
-
50 x 103
3.0
5.0
55
75
-
-
-
-
-
-
-
128
160
160
160
160
8
2
-
2
-
2
-
12
8/20
-
-
50 x 103
3.0
5.0
55
75
-
-
-
-
-
-
-
128
160
200
200
200
8
1000 1000 1000 1000
100
100
2.5/6 2.5/10 2.5/10 2.5/25 2.5/25 10/70 10/70 10/70
-
mm Stud/Cu palm width
mm Min/Max
3.0
30
30
-
-
-
-
80/4
80/1
33
56
-
-
80
80
6
690
80
80
50 x 103
1.3
2.9
30
25
-
-
-
-
63/4
63/1
33
48
-
-
63
63
6
690
63
63
250 x 250 x 250 x 250 x 250 x 103 103 103 103 103
0.6
1.4
15
15
-
-
-
-
40/3
40/1
17
29
-
-
40
40
6
690
40
40
2.6
0.6
1.4
15
15
-
-
-
-
32/3
32/1
17
29
-
-
32
32
6
690
32
32
Compact Panel Isolators 25A - 200A
1.4
0.5
* All AC21, AC22 & AC23 tests carried out at 415V
Connecting capacity
Terminal type
-
2
415V - at 0.65 pf
-
Min. electrical endurance
Operations
-
Min. mechanical endurance
kA rms value
1.2
-
Up to 48V - DC23A
220V - DC23A
-
Up to 48V - DC22A
25/1 25/3
Up to 48V - DC21A
220V - DC21A
220V - DC22A
21 17
400V - AC23A
690V - AC23A
-
400V - AC22A
690V - AC22A
kA Peak value
kW
A
A
Ie
Rated operational current (AC)
25 25
400V - AC21A
6
kV
Rated impulse voltage Uimp
690V - AC21A
690
V
Ui
25
25
Ith
Category
Rated insulation voltage
A
Sym Unit
Rated thermal current
Application
Data supplied against tests to BS EN 60947-3
6
8x25
-
5,000
20 x 103
5
7
37
37
100/3
100/2
100/3
100/2
100/3
100/2
40
100*
100
100*
100
100*
8
750
115
100
8
8x25
-
5,000
20 x 103
5
7
45
45
125/3
125/2
125/3
125/2
125/3
125/2
50
125*
125
125*
125
125*
8
750
125
125
8
8x25
-
1,000
20 x 103
5
7
75
75
160/3
160/2
160/3
160/2
160/3
160/2
63
135*
160
160*
160
160*
8
750
160
160
20
8x25
-
1,000
16 x 103
8
35
170
110
200/2
200/2
200/2
200/2
200/2
200/2
200
200*
200
200*
200
200*
12
1000
200
200
25
10x30
-
1,000
16 x 103
8
35
200
132
250/2
250/2
250/2
250/2
250/2
250/2
250
250*
250
250*
250
250*
12
1000
270
250
350
720*
800
800*
800
800*
12
1000
720
800
-
-
-
1000*
1000
1000*
8
1000
1000
1000
-
500
10 x 103
17
80
355
315
-
500
10 x 103
17
80
355
355
630/2 630/2
630/1 800/1
630/2 800/2
630/1 800/1
-
500
6x 103
50
105
-
400
-
-
-
-
630/2 800/2 1000/3
630/1 800/1 1000/1
350
630*
630
630*
630
630*
12
1000
630
630
25
40
40
40
10x40 12x40 12x40 12x60
-
1,000
10 x 103
17
65
315
200
400/2
400/1
400/2
400/1
400/2
400/2
350
400*
400
400*
400
400*
12
1000
500
400
Standard Panel Isolators 100A - 1000A
Panel Isolators
Panel Isolators Technical Data
Technical Specification - Switch-Disconnectors
Compact Panel Isolators Dimensions A0 Size (25A - 40A) X2 - 180
X3 - 280
A0-A0 Size (6 pole 25A & 40A) X1 - 100
X2 - 195
X3 - 295
AUX
X1 - 80
A1 Size (63A - 80A)
A1-A1 Size (6 pole 63A-80A)
X1 - 98
X1 - 145
X3 - 295
X2 - 240
X3 - 340
AUX
X2 - 195
Panel Isolators
Dimensions
A2 Size (100A - 160A) X1 - 196
X2 - 290
X3 - 390
A3 Size (200A) X1 - 196
X1 X2 X3
X2 - 290
X3 - 390
A2-A2 Size (6 pole 100A-160A) X1 - 196
X2 - 290
X3 - 390
A3 Size (6 pole 200A) X1 - 196 X2 - 290 X3 - 390
Minimum depth. Maximum depth with 100mm shaft extension. Maximum depth with 200mm shaft extension.
www.craigandderricott.com
Page
34
Standard Panel Isolators Dimensions B1 Size
(100A - 160A)
B2 Size
(6P 200A)
B2 Size
(200A - 250A)
B2 Size
(6P 250A)
B4 Size
(400A - 800A)
B4 Size
(6P 315A)
B4 Size
(6P 400A)
Panel Isolators
X1 - 130 X3 - 255 X4 - 455
X1 - 190 X3 - 270 X4 - 470
X1 - 220 X3 - 285 X4 - 485
Rating
A 3P
B 4P
L 3P
Rating
P
Q
S
T
4P
400A
46
25
4
11
400A
211
257
205
151
197
600A
62
40
5
13.5
600A
244
306
223
183
245
800A
70
40
5
13.5
800A
260
330
223
199
269
B4 Size
(1000A)
X1 - 240 X3 - 285 X4 - 485
X1 X3 X4
Page
35
Minimum depth. Maximum depth with 200mm shaft extension. Maximum depth with 400mm shaft extension.
Changeover Isolators 32A - 630A A compact range of load break Changeover Switches suitable for a wide range of applications. Features
• • • •
Catalogue Numbers
Compact ‘piggy-back’ design. On-load AC23A ratings. Supplied as four pole format. Windows for visual contact inspection.
Current Rating
Frame Size
TP&N
The catalogue numbers below include: • On-load AC23A changeover four pole switch. • 200mm standard length shaft assembly. • IP65 door interlocking handle. Typical ‘C2/C3’ Arrangement
Alternative shafts
As an alternative to the standard 200mm shaft a 400mm option is available as indicated below. The shafts are manufactured from square section steel and zinc plated. The height setting is adjusted by passing the shaft through a bush in the switch mechanism and locking it in position using two ‘cup point’ grub screw.
63A
C1C
SCOD00634B
100A
C1C
SCOD01004B
125A
C2C
SCOD01254B
160A
C2C
SCOD01604B
200A
C2C
SCOD02004B
250A
C2
SCOD02504B
400A
C3
SCOD04004B
630A
C3
SCOD06304B
Supplied Handles
Designed to compliment the handles used on our enclosed equipment, the door interlocked versions are capable of being locked with up to three individual padlocks (Ø6.4 max shackle dia). All handles are sealed to IP65 which will enable installations in a wide variety of environmental conditions. If the contacts should weld due to a fault or an excessive current situation, an override facility is provided for the use of a competent person which will allow the enclosure lid to be opened.
‘L’
Load break switch current Rating Shaft length ‘L’
63A - 100A
125A - 200A
250A - 630A
SSH14
SSH18
SSH15
Handle assembly supplied with the ‘C2’
8mm
8mm
12mm2
& ‘C3’ frame size (SDH6/BLK).
400mm Drive Shaft Section Max. possible enclosure depth
2
2
200mm
270
285
330
400mm
470
485
530
Panel Isolators
General Description
Technical Specification - Changeover Switch-Disconnectors Rating (A)
Data supplied against tests to BS EN 60947-3 Application
Sym
Unit
Category
63
100
125
160
200
250
400
630
Rated thermal current
Ithe
A
63
100
125
160
200
250
400
630
Rated insulation voltage
Ui
V
750
750
1000
1000
1000
1000
1000
1000
Uimp
kV
Rated impulse voltage Rated operational current
Ie
A
6
6
6
6
6
12
12
12
415V - AC22A
63
100
125
160
200
250
400
630
415V - AC23A
63
100
125
160
200
250
400
630
Rated making capacity (AC23A)
A
415V, 0.35 pf
630
630
1,250
1,600
2,000
2,500
4,000
6,300
Rated breaking capacity (AC23A)
A
415V, 0.35 pf
504
504
1,000
1,280
1,600
2,000
3,200
5,040
Short circuit current
kA
rms (with fuses)
80
80
80
80
80
100
100
80
Rated S/C making capacity
kA
Peak
15
15
20
20
20
30
40
50
Min. mechanical endurance
-
Operations
20,000
20,000
10,000
10,000
10,000
10,000
10,000
10,000
Min. electrical endurance
-
415V - at 0.65 pf
2,500
1,500
1,000
1,000
1,000
1,000
1,000
500
-
Terminal type 35
35
95
95
95
240
300
400
6x12
6x12
8x22
8x22
8x22
10x25
10x25
12x50
3
3
10
10
10
30
45
50
Connecting capacity
mm2 Max mm Stud/Cu palm width Nm Tightening torque
www.craigandderricott.com
Dimensions Pg 37
Page
36
Changeover Isolators Dimensions Frame Size C1C - 63A & 100A Ratings
Frame Size C2C - 125A, 160A & 200A Ratings
Panel Isolators
80
Frame Sizes C2 / C3 - 250A, 400A, 630A Ratings
Page
37
Frame Size
Rating
a1
b1
c
d
e
f
g
h
j
k
m
n
p
q
C2
250A
309.5
252
61
25
124
138
163
65.5
81
4.0
242
255-355
145
18
C3
400A
352
276
70
25
150
180
205
85
96
4.0
262
300-400
220
26
C3
630A
352
276
70
40
150
185
223
84
98
5.0
262
300-400
220
26
The i-push range has been designed and developed to incorporate safety, functionality and ease of installation incorporating suggestions from re-sellers and end-users.
Heavy & Normal Duty Actuators The ‘i-push’ range incorporates two distinctly different component series Heavy Duty & Normal duty. The Heavy Duty (HD) actuators are manufactured using metal based components and are therefore suitable for use in arduous environments.
Heavy Duty
Normal Duty
The Normal Duty (ND) actuators are manufactured from high strength moulding materials and are suitable for most applications.
(All control stations incorporating Heavy Duty actuators include an ‘H’ in the first part of the catalogue number i.e. EMSH/T/MG/CO). You will also see an ‘HD’ in the title bar above each relevant item.
Control Stations
Introduction
Pushbutton Position Indicator An innovative design feature is included on all ‘normal duty’ Emergency Stop actuators. A green segment forms part of the pushbutton moving body and when visible clearly indicates that the actuator has not been operated. When the button has been depressed and the mechanism latched, then the green segment is no longer visible.
Standby mode
Security lid fixings
Protective Guard
The stainless steel and flush mounting enclosures are supplied as standard with security ‘tamper proof’ style lid fixings.
The ‘i-push’ Normal Duty range includes actuators with an integral guard. This will give the control station protection against accidental operation.
Contents
Safety Contact
Ingress Protection All i-push control stations are sealed to a minimum of IP65 and suitable for indoor and outdoor applications. To withstand the high pressure water cleaning in certain environments Craig and Derricott has developed a stainless steel control station that complies with IP69K water test.
Blue ‘Safety’ Plunger
(See cat No ‘EMS/T/SS/NC69’ - Page 42)
A flexible shroud between the actuator and the enclosure lid assists in meeting the IP69K requirements
Operated & latched
Series Connection
www.craigandderricott.com
Safety contacts are available for Emergency Stop control stations incorporating ‘Clip-in’ type contact blocks. Here a pair of contact blocks are sandwiched together and the contacts connected in series. When inserted the Red plunger will be operated by the pushbutton actuator, the blue plunger will retain a N/C contact when the block is pushed fully home and clicked in place. Should for any reason the block become loose, the contact under the blue plunger will open and initiate a stop function.
Page
38
Control Stations
Introduction Flap Covers
The Heavy Duty ‘i-push’ assemblies include actuators with optional flap cover protection, these are manufactured using die-cast aluminium components and can be supplied in locking or non locking types. • The non-locking flap cover - to provide additional degree of protection against accidental operation of the actuator • The locking flap cover - includes a padlocking feature for up to three padlocks that prevents access to the actuator. We recommend using padlocks with a standard shackle diameter of 6.4mm
Padlocking flap cover fitted to an ‘E. Stop’ control station Emergency Stop stations fitted with Flap Covers are used solely to prevent unauthorised resetting. In an emergency situation, having to lift a flap cover to gain access to the pushbutton is not permissible. Should an emergency occur the flap cover itself is used as the primary ‘Stop’ actuator. When the flap cover is struck this operates the pushbutton actuator. Once operated the pushbutton will latch and will need resetting by hand before the process can resume. It’s here where the flap cover adds an extra level of safety. In the normal running condition the flap cover can be fitted with a padlock(s) whilst still allowing the normal emergency operation. After an emergency operation of the flap cover the padlock will prevent any unauthorised access to reset the actuator.
Bespoke Assemblies Although this catalogue contains a wealth of options, there will always be the case where a bespoke assembly is the only answer to fulfill a precise requirement. Craig & Derricott has over 70 years experience in designing products to meet a specific need, so why not call our Sales team who will be pleased to discuss your requirements.
Page
39
Emergency Stop Emergency Stop stations are designed and installed primarily to provide machine operators with a means of shutting down in the event of a dangerous occurrence taking place. All electrical machines must now be installed with Emergency Stops fitted and specific International Regulations apply to the design, testing and installation of such devices. (IEC/EN60204-1) (BS EN ISO 13850-2) The following pages contain the following options:
• Enclosure formats - Moulded, Polyester, Die-cast Aluminium, Stainless Steel, Flush Mounting & Sheet steel. • ‘Reset’ Methods - Twist-to-Reset, Pull-to-Reset & Key Reset • Protection Devices - Raised Shroud & Flap Cover
Moulded
IP65
Catalogue No. • Actuator • Legend • Contacts • Dims.
ND
EMS/T/P/NC
ND
EMS/K/P/NC
Emergency Stop key reset. (Supplied with 2 keys) ‘Emergency Stop’ yellow anti-lock collar. 1N/C (MT-16A) ‘D2’
ND
EMS/K/PS/CO
ND
EMS/TS/P/NC
ND
Emergency Stop twist-to-reset. Circular yellow Raised shroud 1N/C (MT-16A) ‘D2’
Catalogue No. • Actuator • Guard • Legend • Contacts • Dims.
ND
Emergency Stop key reset (supplied with 2 keys) ‘Emergency Stop’ yellow anti-lock collar. 1N/C+1N/O (ET-10A) ‘D1’
Catalogue No. • Actuator • Legend • Guard • Contacts • Dims.
EMS/T/PS/CO
Emergency Stop twist-to-reset. ‘Emergency Stop’ yellow anti-lock collar. 1N/C+1N/O (ET-10A) ‘D1’
Catalogue No. • Actuator • Legend • Contacts • Dims.
Emergency Stop, twist-to-reset. Circular yellow 1N/C (MT-16A) ‘D2’
Catalogue No. • Actuator • Legend • Contacts • Dims.
EMS/TS/PS/CO
Catalogue No. • Actuator • Legend • Contacts • Dims.
Emergency Stop twist-to-reset. Raised shroud None 1N/C+1N/O (ET-10A) ‘D1’
Catalogue No. • Actuator • Legend • Contacts • Dims.
ND
Emergency Stop, twist-to-reset. None 1N/C+1N/O (ET-10A) ‘D1’
Catalogue No. • Actuator • Guard • Legend • Contacts • Dims.
EMS/TNS/PS/CO
Control Stations
General Description
EMS/KS/P/NC
ND
Emergency Stop key reset. (Supplied with 2 keys) Raised shroud Circular yellow 1N/C (MT-16A) ‘D2’
Dimensions Pg 46
www.craigandderricott.com
Page
40
Control Stations
Emergency Stop Die-Cast Aluminium Catalogue No. • Actuator • Legend • Contacts • Dims.
Page
41
ND
EMSH/P/MR/CO
HD
EMSH/K/MR/CO
HD
• Actuator • Guard • Finish • Legend • Contacts • Dims.
EMSH/P/F1/MR/CO Mushroom, pull-to-reset. Padlocking flap cover Red Printed flap cover 1N/O+1N/C (MT-16A) ‘D5’
Actuator Legend Contacts Dims.
HD
Actuator Guard Legend Contacts Dims.
EMSH/T/MG/CO
HD
EMSH/P/MG/CO
HD
EMSH/K/MG/CO
HD
Mushroom, key reset. (Supplied with 2 x DC800 keys, differs available) Circular yellow. 1N/C+1N/O (MT-16A) ‘D5’
Catalogue No. • • • • •
ND
Mushroom, pull-to-reset. Circular yellow. 1N/C+1N/O (MT-16A) ‘D5’
Catalogue No. • Actuator • Legend • Contacts • Dims.
EMS/KS/MG/NC
Mushroom, twist-to-reset. Circular yellow 1N/C+1N/O (MT-16A) ‘D5’
Catalogue No. • • • •
ND
Emergency Stop, key reset.(Supplied with 2 keys) Raised shroud Circular yellow 1N/C (MT-16A) ‘D5’
Catalogue No. • Actuator • Legend • Contacts • Dims.
Mushroom, key reset. (Supplied with 2 x DC800 key, differs available) Red Circular yellow. 1N/C+1N/O (MT-16A) ‘D5’
Catalogue No.
Dimensions Pg 46
EMS/K/MG/NC
EMS/T/MGS/CO
Emergency Stop, twist-to-reset Printed collar 1N/C + 1N/O (ET-10A) ‘D0’
Catalogue No. • Actuator • Guard • Legend • Contacts • Dims.
Mushroom, pull-to-reset. Circular yellow. Red 1N/C+1N/O (MT-16A) ‘D5’
Catalogue No. • Actuator • Finish • Legend • Contacts • Dims.
ND
Emergency Stop, key reset.(Supplied with 2 keys) Printed collar 1N/C (MT-16A) ‘D5’
Catalogue No. • Actuator • Legend • Finish • Contacts • Dims.
EMS/TS/MG/NC
Catalogue No. • Actuator • Legend • Contacts • Dims.
Emergency Stop, twist-to-reset. Raised shroud Circular yellow 1N/C (MT-16A) ‘D5’
Catalogue No. • Actuator • Legend • Contacts • Dims.
ND
Emergency Stop twist-to-reset. Printed collar 1N/C (MT-16A) ‘D5’
Catalogue No. • Actuator • Guard • Legend • Contacts • Dims.
EMS/T/MG/NC
IP65
EMSH/P/F1/MG/CO
Mushroom, pull-to-reset. Padlocking flap cover Printed flap cover 1N/O+1N/C (MT-16A) ‘D5’
HD
EMSH/T/GP/CO
Catalogue No. • Actuator • Legend • Contacts • Dims.
HD
Mushroom, twist-toreset. Circular yellow 1N/C+1N/O (MT-16A) ‘D4’
EMSH/K/GP/CO
Catalogue No. • Actuator • Legend • Contacts • Dims.
IP65
• • • •
HD
Mushroom, key reset. (Supplied with 2 x DC800 keys, differs available) Circular yellow 1N/C+1N/O (MT-16A) ‘D4’
EMSH/P/GP/CO
Catalogue No. Actuator Legend Contacts Dims.
Mushroom, pull-to-reset. Circular yellow 1N/C+1N/O (MT-16A) ‘D4’
EMSH/P/F1/GP/CO
Catalogue No. • • • • •
Actuator Guard Legend Contacts Dims.
• Actuator • Legend • Finish • Lid fixings • Contacts • Dims.
IP65 EMS/T/SS/NC
Emergency Stop twist-to-reset. Printed collar Brushed Security style screws. 1N/C (MT-16A) ‘D9’
ND
Catalogue No. • Actuator • Lid fixings • Finish • Legend • Contacts • Dims.
• Actuator • Legend • Sealing • Finish • Lid fixings • Contacts • Dims.
EMS/K/SS/NC
ND
Emergency Stop, key reset.(Supplied with 2 keys) Security style screws. Brushed Printed collar 1N/C (MT-16A) ‘D9’
IP69K
Stainless Steel Catalogue No.
HD
Mushroom, pull-to-reset. Padlocking flap cover Printed flap cover 1N/O+1N/C (MT-16A) ‘D4’
Stainless Steel Catalogue No.
HD
Control Stations
Glass Filled Polyester
EMS/T/SS/NC69
Emergency Stop twist-to-reset. Yellow circular. IP69K. Brushed Security style. 1N/C+safety contact (Type MTOSF see page 46) ‘D10’
ND Sealed to withstand the forces associated with pressure washers. Tested to withstand a hose delivering water at a pressure between 80-100 bar at a temperature of 80°C. The combination of a stainless steel enclosure and sealing to IP69K make these items ideally suited to environments where strict hygiene cleaning routines are enforced. Supplied with external fixing feet for vertical or horizontal mounting.
Dimensions Pg 46
www.craigandderricott.com
Page
42
Control Stations
Emergency Stop Flush Mounting
IP65
As supplied there is an IP65 seal between the Pushbutton and the face plate. To maintain this seal when installing the complete assembly the onus is upon the installer to use a continuous bead of flexible sealant to provide an effective seal between the rear of the face plate and what may be an uneven mounting surface.
EMS/T/F/CO
Catalogue No. • Actuator • Legend • Lid fixings • Contacts • Dims.
Emergency Stop twist-to-reset. Printed Collar Security style 1N/C+1N/O (ET-10A) ‘D11’
EMSH/T/F/CO
Catalogue No. • • • • •
Actuator Legend Lid fixings Contacts Dims.
EMSH/K/F/CO
Mushroom, key reset. (Supplied with 2 x DC800 keys, differs available) Circular yellow. 1N/C+1N/O (MT-16A) ‘D11’
Catalogue No. • Actuator • Legend • Lid fixings • Contacts • Dims.
HD
Mushroom, twist-to-reset. Yellow circular. Security style 1N/C+1N/O (MT-16A) ‘D11’
Catalogue No. • Actuator • Legend • Contacts • Dims.
ND
HD
Actuator Legend Lid fixings Contacts Dims.
Actuator Guard Legend Contacts Dims.
EMSH/P/F/CO
EMSH/P/F1/F/CO
• Actuator • Fitting • Contacts • Dims.
Dimensions Pg 46
Page
43
HD
Mushroom, pull-to-reset. Padlocking flap cover Pad printed flap cover 1N/O+1N/C (MT-16A) ‘D11’
IP65
Sheet Steel
Catalogue No.
HD
Mushroom, pull-to-reset. Yellow circular. Security style 1N/C+1N/O (MT-16A) ‘D11’
Catalogue No. • • • • •
ND
Emergency Stop, key reset.(Supplied with 2 keys) Printed collar Security style 1N/C+1N/O (ET-10A) ‘D11’
Catalogue No. • • • • •
EMS/K/F/CO
EMS/T/FS/NC
Emergency Stop, twist-to-reset. Pattress box or trucking as shown:2xN/C with ‘faston’ terminals (Monobloc-5A) ‘D8’
ND • Can be installed in dado trunking as shown.
General Description
‘Emergency Power Off’ or ‘EPO’ control stations can be used where the safety requirements associated with Emergency Stops are not required. Typical uses would include:• Computer Suites • School Workshops
• •
Water Treatment Plants Service & Maintenance
All items are housed in robust die-cast aluminium enclosures with flap covers to prevent accidental operation.
Die-Cast Aluminium Catalogue No. • • • • •
Actuator Guard Legend Contacts Dims
EPO/T/F5/MG/CO
ND
Mushroom twist-to-reset. Flap cover non-locking. Printed flap cover. 1N/C + 1N/O (MT-16A) ‘D5’
Catalogue No. • Actuator • Guard • Legend • Contacts • Dims
IP65
• • • • •
EPO/T/F5/MGS/CO
ND
Twist-to-reset Flap cover Printed flap cover 1NC + 1N/O (ET-10A) ‘D0’
EPO/K/F5/MG/CO
Catalogue No. Actuator Guard Legend Contacts Dims
Mushroom key reset. Flap cover non-locking. Printed flap cover. 1N/C + 1N/O (MT-16A) ‘D5’
EPO/K/F5/MGS/CO
Catalogue No. • • • • •
Actuator Guard Legend Contacts Dims
ND
Control Stations
EPO/Accessories
ND
Key Reset Flap cover Printed flap cover 1NC + 1N/O (ET-10A) ‘D0’
IP65
Accessories Contact blocks are available to replace or extend the arrangements supplied as standard.
Catalogue No.
MTO
‘MT’ Series
The ‘MT’ series are designed as ‘clip-in’ modules which can be supplied in N/O, N/C & safety formats. The clip-in housing allows for a total of three blocks per actuator.
Normally Closed (N/C) contact block. Momentary action.
Electrical Ratings - BS EN 60947-5-1 Catalogue No.
a.c.
d.c.
AC15 A600
DC13 Q600
600V
600V
Rated Operational Voltage (Ue)
250V / 440V
440V / 250V / 125V / 60V / 24V
[Rated Operational Current (Ie)]
3A / 1.6A
0.12A / 0.2A / 0.4A / 1A / 2A
Breaking Capacity
10Ie
1.1Ie
Continuous thermal current (Ith)
16A
16A
Utilisation Category
Rated Insulation Voltage (Ui)
MTOSFE
‘Safety Contact’ for Emergency Stops. As MTO block but with an added contact which detects if the block becomes loose from its housing.
Catalogue No.
MTI
Normally Open (N/O) contact block. Momentary action.
www.craigandderricott.com
Dimensions Pg 46
Page
44
Control Stations
Accessories ‘ET’ Series
The ‘ETR’ block provides N/O + N/C contacts in one assembly. Catalogue No.
Electrical Ratings - BS EN 60947-5-1
ETR
Contact Block, Momentary Action 1 N/O + 1 N/C
a.c.
d.c.
Utilisation Category
AC15
DC13
Rated Insulation Voltage (Ui)
400V
400V
Rated Operational Voltage (Ue)
400V / 250V
400V / 250V / 125V / 60V / 24V
[Rated Operational Current (Ie)]
3A / 5A
0.12A / 0.2A / 0.4A / 1A / 2A
Breaking Capacity
10Ie
1.1Ie
Continuous thermal current (Ith)
10A
10A
‘Monobloc’
The Monobloc assembly is designed for use in very restricted space. The contacts are assembled in the base of the actuator and cannot be supplied separately. To replace the contacts will require a new complete actuator. Catalogue No.
FVRKOO
Electrical Ratings - BS EN 60947-5-1 a.c. Utilisation Category
AC15 B300
Rated Insulation Voltage (Ui)
250V
Rated Operational Voltage (Ue)
240V / 120V
[Rated Operational Current (Ie)]
1.5A / 3A
Breaking Capacity
Contact Block, Momentary Action 2 N/C
Continuous thermal current (Ith)
10Ie 5A
‘S1’ Series
The S1 contact block is designed to be stacked in pairs side-by-side and then back-to-back making a total on four changeover blocks on one Heavy Duty actuator. Three or four blocks will require extended fixing screws (U42) Catalogue No.
S1
Electrical Ratings - BS EN 60947-5-1 a.c.
NC
NC
Utilisation Category
AC15
Rated Insulation Voltage (Ui)
660V
NO
NO
Rated Operational Voltage (Ue)
400V
Image shows 2 off S1 blocks
[Rated Operational Current (Ie)]
5A
Continuous thermal current (Ith)
10A
Contact Block, Momentary Action C/O
Catalogue No.
U42
Assembly screw kit to enable 3 or 4 ‘S1’ contacts to be mounted on a single Heavy Duty actuator.
Mechanical Endurance:All HD assemblies with the exception of Emergency Stops 1x106 operations HD Emergency Stop (Twist-to-reset & pull-to-reset) 0.25x106 operations All ND assemblies 1x106 operations
Page
45
D0
Material: Colour: Entries: Fixings:
Die-cast Aluminium Grey (RAL 7001) Plain sides 2xM4
Material: Colour: Entries: Fixings:
D4
Steel Silver 5xM20 knockouts 4 off 5x10 slots
Material: Die-cast Aluminium Colour: Grey (RAL 7035) Red (RAL 3020) Entries: 2xM20 Fixings: 4xM5
Material: Finish: Entries: Fixings:
Material: Colour: Entries: Fixings:
Polycarbonate Grey (RAL 7035) Plain sides 4xM4
Material: Die-cast Aluminium Colour: Grey (RAL 7035) Entries: 2xM20 Fixings: 4xM5
Material: Finish: Entries: Fixings:
Polycarbonate Grey (RAL 7035) Plain sides 4xM4
Material: Die-cast Aluminium Colour: Grey (RAL 7035) Entries: 2xM20 Fixings: 4xM5
D11
D10
Stainless steel (Grade 304) Brushed 2xM20 4xM6
Material: Colour: Entries: Fixings:
D7
D6
D9
D8
Material: Colour: Entries: Fixings:
Polycarbonate Yellow/Black 2xM20 2xM4
D5
Material: Glass reinforced Polyester Colour: Grey (RAL 7000) Entries: Plain sides Fixings: 4xM5
D3
D2
D1
Control Stations
Dimensions
Stainless steel (Grade 304) Brushed 1xM20 4xM6
Material: Finish: Entries: Fixings:
Fascia plate - Stainless Steel Back box - Galvanised steel Fascia plate - Brushed 9xM20 knockouts 4xM5
Actuator Projections Normal Duty Actuators (ND) Emergency Stop (incl. guards) Start/Stop
42mm 11mm
Heavy Duty Actuators (HD) Mushroom (Twist or pull to reset) 43mm Mushroom (Key reset) 51mm Full guard (Start/Stop) 30mm Flap Cover 66mm
www.craigandderricott.com
Page
46
Made to order Assemblies
Bespoke Assemblies Take advantage of our bespoke ‘mi-switch’ service. ‘Made to order’ products at competitive prices.
Technical Data Page Dimensions Page
Page
47
Projects within the GCC Projects within the GCC
Craig & Derricott has been supplying equipment for prestigious projects across the GCC for many years. Some of the more recent are shown below:-
www.craigandderricott.com
Page
48
Notes Your local Area Sales Manager .................................................. Mob. Telephone No.
..................................................
Notes Page
email address ..................................................
Page
49
Your Internal Sales Contact
..................................................
Direct.Telephone No.
..................................................
email address ..................................................
Notes Your local Area Sales Manager .................................................. Mob. Telephone No.
..................................................
Your Internal Sales Contact
..................................................
Direct.Telephone No.
..................................................
email address ..................................................
www.craigandderricott.com
Notes Page
email address ..................................................
Page
50
51
Middle East Office:-
Craig & Derricott FZC Dubai United Arab Emirates. t: 00971(0)50 3554080 00971(0)52 9909555 e: sales@craigandderricott.com
C&D Export Catalogue Issue 4 CDPD11
Page
Craig & Derricott Ltd. Hall Lane, Walsall Wood, Walsall, West Midlands WS9 9DP U.K. t: +44(0)1543 375541 e: sales@craigandderricott.com
C&D Website
Head Office:-