ELIMINATE EMI ISSUES WITH OPEN SIM WHEEL
Carlos Casas CEO & Community Manager
https://simracingcoach.com https://tiendasimracing.com
UPDATES:
1. Grounding 2. Cable USB with ferrite 3. Other tips 4. Solving issues with Leo Bodnar Bu0036A
Carlos Casas
ELIMINATE EMI ISSUES Open Sim Wheel uses Industrial Servo Motors, so maybe, they can cause EMI issues in other Usb devices of our computer. To eliminate them, there are some steps.
1. Grounding Grounding is the perfect way for solving these issues.
Kit Augury OSW Kit de Augury includes the Ground cable between Electronic Box and Motor/chassis. I.
Important: Ground cable must be separated from 2 big motor cables.
II.
Put one end of ground cable from Electronic Box to one of 4 front holes (Metric 8) of Motor and Stand.
2 Carlos Casas
III.
Other end of Ground cable to chassis (fork if is necessary) .
3 Carlos Casas
Other Kits OSW For other OSW kits that don’t have Ground cable, open the Electronic Box (Unplugged) and put the Ground cable in the Ground connector (Power Supply). (Don’t make it before contact with the supplier of OSW) Procedure
Ground connector of Power Supply.
4 Carlos Casas
OPTIONAL. Use cable of 1,5 or 2 mm thickness, with open terminal.
5 Carlos Casas
Direct Drive systems without external ground For Direct Drive systems without external ground, we can use a Power Supply cable like this and cut the end. Then, cut and tap the blue and brown wire, and use the yellow/green with terminales and screw them in the chassis, motor stand and servomotor.
6 Carlos Casas
Steps -
Use closed and opened terminals.
-
Put one end in the Electronic box.
7 Carlos Casas
-
Another end in chassis.
Another end to Motor Stand and Motor.
8 Carlos Casas
2. Cable USB with ferrite
If USB cable between BOX and computer doesn’t have Ferrites, buy one similar of next links.
KITS OSW WITH SIMUCUBE AND MINI USB CONNECTION Cable of 2 meters - Link Cable of 3 meters - Link
OLD KITS OSW Cable of 2 meters - Link Cable of 3 meters - Link
9 Carlos Casas
3. Other tips
Use this USB device in order to filter Emis.
Use an USB Hub Powered.
This model is recommended.
10 Carlos Casas
Use a PCI-Express USB 2.0 for connecting the OSW
This model is recommended Or other similar models
Insolate the 2 big motor cables. Link.
It is recommended to use the USB 2.0 in the computer. Separate the Electronic BOX from the Computer (Minimum 50 cm) Don’t use USB extension between Box to computer. Use Grounding Plugs.
11 Carlos Casas
It is recommended to use safe strip protection and ferrite in cables of other devices USB.
https://www.simracingcoach.com/contenido/proteger-aislar-ruido-electrico-en-el-simulador/
If is possible, use other Plug for Kit OSW.
Use a mat between floor and chassis.
Don’t put the Electronic Box above the computer..
12 Carlos Casas
4. Solving issues with Leo Bodnar Bu0036A Occasionally, emis can cause fails in USB Leo Bodnar controller. It’s important grounding this board. Steps for loading again the firmware.
-Download this file Link -Rename to Bodnar_Pedal_V2_Firmware.rar -Unzip -Unplug all devices from de computer. -Run the file HE-Sim-Ver2.exe
GENERAL INSTRUCTIONS
There is a fix for this. I've attached a file: - Download to your computer - Rename to .zip (Google mail security doesn't allow us to send Zip files containing programs) - Extract the 2 files somewhere on your computer HE-Sim-Ver2.bin HE-Sim-Ver2.exe Disconnect all USB controllers (wheel, shifters, button boxes) except the pedals. Start the HE-Sim-Ver2.exe You get a 'Firmware update' screen. If it detects the device you will see some information about manufacturer, product, versoin etc. If one of them says 'Bootloader' here, click 'Upgrade Firmware' to re-apply the proper firmware. If nothing is listed or detected you may attempt this on a second computer or laptop, but then it is likely the device has failed and we have to ship a new controller. Let us know how that goes or if you need assistance with this!
13 Carlos Casas
Si tienes alguna duda, contacta conmigo a través de carlos@simracingcoach.com