ALVIN DUNN K-8 SCHOOL PHASE 3 - BUILDING C 3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
RUHNAU RUHNAU CLARKE
2.
CONSTRUCTION CREW SHALL WEAR APPROPRIATE SAFETY GEAR AND COMPLY WITH CURRENT APPLICABLE SAFETY REGULATIONS.
3.
CONSTRUCTION CREW SHALL ADHERE TO BEHAVIOR AND DRESS CODE THAT IS APPROPRIATE FOR SCHOOL AND ACCEPTABLE WITH DISTRICT REPRESENTATIVES.
4.
SMOKING SHALL NOT BE ALLOWED ON CAMPUS.
5.
THERE SHALL BE NO POSSESSION OR CONSUMPTION OF DRUGS OR ALCOHOLIC BEVERAGES ON THE JOB SITE BY ANY PERSON. ANYONE WHO DOES NOT COMPLY WITH THESE REQUIREMENTS SHALL BE DIRECTED TO LEAVE THE JOB SITE AND WILL NOT BE PERMITTED TO RETURN DURING THE REMAINDER OF THE CONTRACT.
6. THE CONTRACTOR SHALL COMPLY WITH CALIFORNIA FIRE CODE, CHAPTER 33 FOR FIRE SAFETY DURING CONSTRUCTION. 7.
8. Mechanical & Plumbing MA Engineers 5160 Carroll Canyon Rd, Suite 200 San Diego, CA 92121 Phone: 858. 200.0030 Contact: Roy Campbell rcampbell@ma-engr.com
Electrical Johnson Consulting Engineers, Inc. 4750 East Ontario Mills Parkway Ontario, CA 91764 Phone: 858.679.4030 Contact: Jeff Rastrelli jrastrelli@jce-inc.com
Sprinklers Protection Design and Consulting 2851 Camino Del Rio South San Diego, CA 92108 Phone: 619.255.8964 Contact: Stephen Leyton steve@protectiondesign.com
TYPICAL ABBREVIATIONS @ & <
AT AND ANGLE
ACPL ACT AFF
ACOUSTIC PLASTER ACOUSTIC TILE ABOVE FINISHED FLOOR
BLKG BD BOS BB
BLOCKING BOARD BOTTOM OF STRUCTURE BULTTETIN BOARD
CAB CPT CSWK CLG CEM CPL CL CT CLF CLR COL CONC CMU CJ CONT CF
CABINET CARPET CASEWORK CEILING CEMENT CEMENT PLASTER CENTERLINE CERAMIC TILE CHAIN LINK FENCE CLEAR COLUMN CONCRETE CONCRETE MASONRY UNIT COLD JOINT CONTINUOUS CUBIC FEET
FS FOM FOS FIN FC FG FFE
FLOOR SINK FACE OF MASONRY FACE OF STUD FINISH FINISH CEILING FINISH GRADE FINISH FLOOR GRADE
HIGH HARDWARE HORIZONTAL HOUR HEIGHT
ID INSUL INT
INSIDE DIAMETER INSULATION INTERIOR
JH JT JST
JOIST HANGER JOINT JOIST
LAM LT LVR
LAMINATE LIGHT LOUVER
MACH MAX MECH MIN MH MFR MO MTL ML MS MTD
MACHINE MAXIMUM MECHANICAL MINIMUM MANHOLE MANUFACTURER MASONRY OPENING METAL METAL LATHE METAL STUD MOUNTED
NTC NTS NO
NOT IN CONTRACT NOT TO SCALE NUMBER
OC OD OFCI OH OPNG OPP
ON CENTER OUTSIDE DIAMETER OWNER FURNISHED/ CONTRACTOR INSTALLED OPPOSITE HAND/OVERHEAD OPENING OPPOSITE
PA PFIN PL PLAS PLWD PTD PTN
PLANTING AREA PRE FINISHED PLATE/PROPERTY LINE PLASTIC PLYWOOD PAINTED PARTITION
RRC PROJECT No. : 1-84-28E 12/12/2017 6:55:30 PM DRAWN BY:
CHECKED BY:
O
ROUND
SRF
SHT SHTH SC SB STN STD STL STR SUSP SM SIM
SEAMLESS RESILIENT FLOORING SERVICE SINK/ STAINLESS STEEL SHEET SHEATHING SOLID CORE SPLASH BLOCK STAIN STANDARD STEEL STRUCTURAL/STRUCTURE SUSPENDED SHEET METAL SIMILAR
TB TJ TC TS TW TYP TEL TEMP TOS TOP TOW
TACK BOARD TOOLED JOINT TOP OF CONCRETE CURB TUBE STEEL TOP OF WALK TYPICAL TELEPHONE TEMPERATURE TOP OF STRUCTURE TOP OF PARAPET TOP OF WALL
UC
UNDER CUT/ UNDER COUNTER UNLESS NOTED OTHERWISE
SS
UNO
VERT VC VCT VT VSF VWC VIF VTR
VERTICAL VINYL COATED VINYL COMPOSITION TILE VINYL TILE VINYL SHEET FLOORING VINYL WALL COVERING VERIFIED IN FIELD VENT THROUGH ROOF
WWF WI
WELD WIRE FABRIC WOODWORKING INSTITUTE WINDOW WITH WOOD WITHOUT
WIN W/ WD W/O
STRUCTURAL MODIFICATIONS SHALL BE MADE BY ADDENDUM OR CONSTRUCTION CHANGE DOCUMENT (C.C.D.) APPROVED BY DSA PER SECTION 4-338, PART 1, TITLE 24.
11.
A PROJECT INSPECTOR, EMPLOYED BY THE DISTRICT (OWNER) AND APPROVED BY THE DIVISION OF THE STATE ARCHITECT, SHALL PROVIDE CONTINUOUS INSPECTION OF THE WORK. THE DUTIES OF THE INSPECTOR IS DEFINED IN SECTION 4-342, PART 1, TITLE 24, C.C.R. THE INSPECTOR SHALL BE ESPECIALLY QUALIFIED IN MECHANICAL AND ELECTRICAL WORK AND HAVE SUCCESSFULLY COMPLETED THE REQUIRED DSA CERTIFICATION PROCESS FOR CLASS 1 INSPECTOR OF RECORD AND A R.B.I.P.
12.
THE ARCHITECT OF RECORD SHALL HAVE THE RIGHT TO MAKE FINAL JUDGMENTS RELATIVE TO SUBMITTAL DRAWING REVISIONS IN ORDER TO ENSURE COMPLIANCE WITH ENGINEERING STANDARDS, APPLICABLE CODES, AND ARCHITECTURAL INTENT.
13.
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND LOCATIONS OF EXISTING CONDITIONS ON THE JOB SITE PRIOR TO THE START OF ANY WORK. NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND CONSTRUCTION DOCUMENTS. EXISTING CONDITIONS ARE INDICATED AS A RESULT OF INFORMATION SHOWN ON AVAILABLE DOCUMENTS. ANY DAMAGE TO EXISTING CONDITIONS IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
14.
OCCUPATIONAL SAFETY AND HEALTH, THESE DOCUMENTS, AND THE CONSTRUCTION HEREBY CONTEMPLATED, IS TO BE CONTINUOUSLY GOVERNED BY APPLICABLE PROVISIONS OF THE CALIFORNIA OCCUPATIONAL SAFETY AND HEALTH ACT OF 1973, (CAL/OSHA) AND ALL UPDATES THEREAFTER.
15.
THE EXISTENCE OR LOCATION OF ANY UNDERGROUND UTILITIES, PIPES, OR STRUCTURE SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, EXISTING UTILITIES ARE AS SHOWN ON THESE PLANS. THE CONTRACTOR SHALL ASCERTAIN THE TRUE VERTICAL AND HORIZONTAL LOCATION AND SIZE OF ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR DAMAGE TO ANY PUBLIC OR PRIVATE UTILITIES SHOWN OR NOT SHOWN HEREON.
16.
THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ADEQUACY AND SAFETY OF THE DESIGN/ERECTION OF BRACING, SHORING, TEMPORARY SUPPORTS AND SCAFFOLDING.
17.
UNDER NO CIRCUMSTANCE SHALL WORKING DIMENSIONS BE SCALED FROM PLANS, SECTIONS, OR DETAILS ON THE DRAWINGS.
18.
ALL STANDARDS, MATERIALS AND WORKMANSHIP SHALL COMPLY WITH THE STATE BUILDING CODES, ORDINANCES, REGULATIONS, AND LAWS.
19.
WHERE ANY CONFLICT OCCURS BETWEEN THE REQUIREMENTS OF FEDERAL, STATE AND LOCAL LAWS, CODES, ORDINANCES, RULES AND REGULATIONS, THE MOST STRINGENT SHALL GOVERN.
20.
ITEMS MARKED "TYP." OR "TYPICAL" SHALL APPLY IN ALL CASES UNLESS SPECIFICALLY INDICATED OTHERWISE.
21.
22.
23.
24.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF REQUIREMENTS BETWEEN THE DISCIPLINES (ARCHITECTURAL, STRUCTURAL, PLUMBING, MECHANICAL, AND ELECTRICAL, ETC.) AND BETWEEN DRAWING AND SPECIFICATION IN ORDER TO ENSURE THAT ALL ITEMS SHOWN IN RELATIONSHIP TO ONE ANOTHER OR SHOWN IN MULTIPLE LOCATIONS ARE IN AGREEMENT. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT REGARDING ANY DISCREPANCIES, ERRORS, OMISSIONS OR INCONSISTENCIES AND SHALL NOT PROCEED WITH THE WORK UNTIL CLARIFICATION HAS BEEN ISSUED BY THE ARCHITECT. ALL WORK SHALL BE DONE IN ACCORDANCE WITH TITLE 24 CALIFORNIA CODE OF REGULATIONS (CCR) GRADING PLANS DRAINAGE IMPROVEMENTS, ROAD & ACCESS REQUIREMENTS AND ENVIRONMENTAL HEALTH CONSIDERATIONS SHALL COMPLY WITH ALL LOCAL ORDINANCES. INSPECTOR OF RECORD (IOR CLASSIFICATION 1). INSPECTOR OF RECORD SHALL BE DSA APPROVED AND CONFORM TO CLASS 1 CLASSIFICATION CRITERIA AS PROVIDED IN THE INTERPRETATION OF REGULATIONS (IR) A-7, DATED 07-17-13 IN NO CASE SHALL WORKING DIMENSIONS BE SCALED FROM CONSTRUCTION DOCUMENT DRAWINGS.
3. 4.
GENERAL T1
ADDITION OF NEW AC PAVED OUTDOOR PLAY AREA. NEW BUS DRIVEWAY AND LOADING AREA
FABRICATION OF DEFERRED SUBMITTAL ITEMS SHALL NOT BE STANDARDS UNTIL CONTRACTOR'S DRAWINGS, SPECIFICATION AND ENGINEERING CALCULATIONS FOR THE ACTUAL SYSTEM TO BE INSTALLED HAVE BEEN ACCEPTED AND SIGNED BY THE ARCHITECT OR STRUCTURAL ENGINEERING OF RECORD AND APPROVED BY DSA. (CBC, TITLE 24, PART 1 SECTION 4-317(g))
REGIONAL MAP
SITE MAP
CIVIL C3-1.1 C3-2.1 C3-3.1 C3-4.1 C3-5.1 C3-5.2 C3-6.1 RETAINING WALL RW-1 RW-2 RW-3 RW-4
TITLE SHEET
TITLE SHEET TOPOGRAPHIC MAP PRECISE GRADING PLAN COMPOSITE UTILITY PLAN DETAILS SHEET STANDARD DETAILS HORIZONTAL CONTROL PLAN / DATA CHARTS
VERDURA VERDURA VERDURA VERDURA
RETAINING RETAINING RETAINING RETAINING
WALL WALL WALL WALL
GENERAL NOTES PLAN AND PROFILE PLAN AND PROFILE STANDARD DETAILS
LANDSCAPE L-1 LI-1 LI-2 LI-3 LP-1 LP-2
DESIGN DEVELOPMENT LANDSCAPE PLAN IRRIGATION PLAN IRRIGATION LEGEND/NOTES IRRIGATION DETAILS PLANTING PLAN PLANTING LEGEND/DETAILS
ARCHITECTURAL AS-0.1 AS-0.2 AS-0.3 AS-1.1 AS-2.1 AS-2.2 ASD-1.1 ASD-1.2 A1_1.1 A1_1.2 A1_2.1 A1_3.1 A1_4.1 A1_5.1 A1_5.2 A1_6.1 A1_6.2 A1_6.3 A1_6.4 A1_7.1 A1_7.2 A1_7.3 A1_7.4 A1_7.5 A1_7.6 A1_7.7 A1_7.8 A1_7.9 A1_8.1 A1_9.1 A1_9.2 A1_9.3 A1_9.4 AD1.1 AD1.2 AD2.1 AD3.1 AD3.2 AD4.1 AD5.1 AD7.1 AD7.2 AD9.1
CODE ANALYSIS EGRESS & LIFE SAFETY PLAN SITE PLAN FIRE AUTHORITY DEMO SITE PLAN OVERALL SITE PLAN ENLARGED SITE PLAN SITE DETAILS SITE DETAILS FLOOR PLAN SLAB PLAN REFLECTED CEILING PLAN ROOF PLAN BUILDING ELEVATIONS BUILDING SECTIONS BUILDING SECTIONS WALL SECTIONS WALL SECTIONS WALL SECTIONS WALL SECTIONS ENLARGED STAIRS & RAMPS ENLARGED STAIRS & RAMPS ENLARGED PLANS / INTERIOR ELEVATIONS ENLARGED PLANS / INTERIOR ELEVATIONS ENLARGED PLANS / INTERIOR ELEVATIONS INTERIOR ELEVATIONS INTERIOR ELEVATIONS INTERIOR ELEVATIONS INTERIOR ELEVATIONS DOOR & WINDOW SCHEDULE FINISH SCHEDULE & LEGEND FINISHES PLAN ENLARGED GYM FLOOR PLANS SIGNAGE PLAN WALL TYPES WALL VERTICAL CIRCULATION ROOF ROOF CEILING DOOR & WINDOW BUILDING CASEWORK SIGNAGE
STRUCTURAL S0.1 S0.2 S0.3 S0.4 S0.5 S0.6 S0.7 S0.8 S0.9 S0.10 S1-1.1 S1-3.1 S1-3.2 S1-4.1 S1-4.2 S1-4.3 S1-4.4 S1-4.10 S1_4.5 S1_4.6 S1_4.7 S1_4.8 S1_4.9 SD-1.1 SD-3.1 SD-3.2
GENERAL NOTES GENERAL NOTES TYPICAL CONCRETE DETAILS TYPICAL REINFORCING DETAILS TYPICAL MASONRY & CONCRETE DETAILS TYPICAL STEEL DETAILS TYPICAL METAL DECK DETAILS TYPICAL METAL DECK DETAILS TYPICAL METAL STUD DETAILS TYPICAL METAL STUD DETAILS FOUNDATION PLAN LOW ROOF FRAMING PLAN HIGH ROOF FRAMING PLAN CMU WALL ELEVATIONS CMU WALL ELEVATIONS CMU WALL ELEVATIONS CMU WALL ELEVATIONS CMU WALL ELEVATIONS CMU WALL ELEVATIONS CMU WALL ELEVATIONS CMU WALL ELEVATIONS CMU WALL ELEVATIONS CMU WALL ELEVATIONS FOUNDATION DETAILS ROOF FRAMING DETAILS ROOF FRAMING DETAILS
MECHANICAL M-0.1 M-0.2 M-0.3 M-0.4
MECHANICAL GENERAL NOTES AND SCHEDULES MECHANICAL SCHEDULES TITLE 24 TITLE 24
SHEET NAME
M-0.5 M-0.6 M-1.0 M-2.1 M-3.1 M-5.1 M-6.1 M-6.2 M-6.3
TITLE 24 TITLE 24 MECHANICAL MECHANICAL MECHANICAL MECHANICAL CONTROLS CONTROLS CONTROLS
PLUMBING P-0.1 P-0.2 P-2.1 P-2.2 P-3.1 P-3.2 P-5.1
PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING
ELECTRICAL E1.0 E1.1 E2.0.1 E2.0.2 E2.1 E2.2 E2.3 E2.4 E2.5 E2.6 E2.7 E3.1 E3.2 E3.3 E4.0 E4.1 E4.2 E4.3 E4.4 E4.5 E4.6 E4.7 E5.1 E5.2 E5.3 E5.4 E6.1 E6.2 E7.1 E7.2 E7.3 E8.1 E9.1 E9.2
ELECTRICAL LEGEND & NOTES ELECTRICAL SITE PLAN TITLE 24 CALCULATIONS TITLE 24 CALCULATIONS FLOOR PLAN-LIGHTING LIGHTING FIXTURE SCHEDULE LIGHTING DETAILS LIGHTING DETAILS LIGHTING DETAILS THEATRICAL LIGHING DETAILS THEATRICAL LIGHTING PLAN FIRST FLOOR PLAN POWER ENLARGED KITCHEN PLAN POWER DETAILS COMMUNICATION LEGEND FIRST FLOOR PLAN COMMUNICATIONS COMMUNICATION DETAILS COMMUNICATION DETAILS COMMUNICATION DETAILS AUDIO / VISUAL SYSTEMS, DIAGRAMS & DETAILS AUDIO / VISUAL SYSTEMS, DIAGRAMS & DETAILS AUDIO / VISUAL SYSTEMS, DIAGRAMS & DETAILS FIRST FLOOR PLAN FIRE ALARM FIRE ALARM SCHEDULES AND NOTES FIRE ALARM RISER DIAGRAM AND CALCULATIONS FIRE ALARM DETAILS ROOF PLAN ELECTRICAL MECHANICAL SCHEDULE ONE LINE DIAGRAM ONE LINE DETAILS ONE LINE DETAILS ELECTRICAL DETAILS PANEL SCHEDULES PANEL SCHEDULES
FIRE PROTECTION FP-1.0 FP-1.1 FP-1.2 FP-2.0 FP-3.0 FP-4.0 FP-4.1 FP-4.2
GENERAL NOTES UNDERGROUND PIPING PLAN UNDERGROUND PLAN DETAILS FIRE PROTECTION PIPING PLAN FIRE PROTECTION RCP PLAN DETAILS DETAILS SECTIOS
FOOD SERVICE FS-0 FS-1 FS-2 FS-3 FS-4 FS-5 FS-6.1 FS-6.2 FS-7 FS-8.1 FS-8.2 FS-9 SHADE SHELTER MT20.0 MT20.1
ZONING PLAN FLOOR PLAN ROOF PLAN DETAILS
GENERAL NOTES SCHEDULE FLOOR PLAN ROOF PLAN ENLARGED PLANS ENLARGED PLANS - KITCHEN DETAILS
FOODSERVICE FOODSERVICE FOODSERVICE FOODSERVICE FOODSERVICE FOODSERVICE FOODSERVICE FOODSERVICE FOODSERVICE FOODSERVICE FOODSERVICE FOODSERVICE
TITLE SHEET - MPR BLDG. C SCHEUDLE ELECTRICAL ROUGH-IN PLUMBING ROUGH-IN ELEVATIONS SECTIONS & DETAILS SECTIONS & DETAILS SEISMIC DETAILS - EXHAUST HOODS - EXHAUST HOODS REFRIGERATION RACK
NOTIFY ARCHITECT OF ALL DISCREPANCIES! STATEMENT OF GENERAL CONFORMANCE THESE DRAWINGS AND / OR SPECIFICATIONS AND / OR CALCULATIONS FOR THE ITEMS LISTED ON THE SHEET INDEX HAVE BEEN PREPARED BY OTHER DESIGN PROFESSIONALS OR CONSULTANTS WHO ARE LICENSED AND OR / AUTHORIZED TO PREPARE SUCH DRAWINGS IN THIS STATE. THESE DOCUMENTS HAVE BEEN EXAMINED BY ME FOR DESIGN INTENT AND APPEAR TO MEET THE APPROPRIATE REQUIREMENTS OF TITLE 24, CALIFORNIA CODE OF REGULATIONS AND THE PROJECT SPECIFICATIONS PREPARED BY ME. ITEMS LISTED HAVE BEEN COORDINATED WITH MY PLANS AND SPECIFICATIONS AND ARE ACCEPTABLE FOR INCORPORATION INTO THE CONSTRUCTION OF THIS PROJECT FOR WHICH I AM THE INDIVIDUAL DESIGNATED TO BE IN GENERAL RESPONSIBLE CHARGE. DAVID RUHNAU PRINT NAME
DATE
C - 20662 LICENSED NUMBER
EXPIRTATION DATE
APPLICABLE CODES APPLICABLE CODES AS OF JANUARY 1, 2017* 2016 BUILDING STANDARDS ADMINISTRATIVE CODE (CAC), PART 1, TITLE 24 C.C.R.* 2016 CALIFORNIA BUILDING CODE (CBC), PART 2, TITLE 24 C.C.R. (2015 INTERNATIONAL BUILDING CODE VOLUMES 1 & 2 AND 2016 CALIFORNIA AMENDMENTS) 2016 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, TITLE 24 C.C.R. (2014 NATIONAL ELECTRICAL CODE AND 2016 CALIFORNIA AMENDMENTS) 2016 CALIFORNIA MECHANICAL CODE (CMC) PART 4, TITLE 24 C.C.R. (2015 IAPMO UNIFORM MECHANICAL CODE AND 2016 CALIFORNIA AMENDMENTS) 2016 CALIFORNIA PLUMBING CODE (CPC), PART 5, TITLE 24 C.C.R. (2015 IAPMO UNIFORM PLUMBING CODE AND 2016 CALIFORNIA AMENDMENTS) 2016 CALIFORNIA ENERGY CODE (CEC), PART 6, TITLE 24 C.C.R. 2016 CALIFORNIA FIRE CODE (CFC), PART 9, TITLE 24 C.C.R. (2015 INTERNATIONAL FIRE CODE AND 2016 CALIFORNIA AMENDMENTS) 2016 CALIFORNIA EXISTING BUILDING CODE (CEBC), PART 10, TITLE 24 C.C.R. (2015 INTERNATIONAL EXISTING BUILDING CODE & 2016 CALIFORNIA AMENDMENTS) 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE (CAL GREEN), PART 11, TITLE 24 C.C.R. 2016 CALIFORNIA REFERENCED STANDARDS CODE, PART 12, TITLE 24 C.C.R. TITLE 19 C.C.R, PUBLIC SAFETY, SATE FIRE MARSHAL REGULATIONS 2013 ASME A17.1/CSA B44-13 SAFETY CODE FOR ELEVATORS AND ESCALATORS PARTIAL LIST OF APPLICABLE STANDARDS NFPA 13 STANDARD FOR THE INSTALLATION SPRINKLER SYSTM. (CA AMENDED) NFPA 14 STANDARD FOR THE INSTALLATION OF STANDPIPE & HOSE SYSTEMS NFPA 17 STANDARD FOR DRY CHEMICAL EXTINGUISHING SYSTEMS NFPA 17A STANDARD FOR WET CHEMICAL EXTINGUISHING SYSTEMS NFPA 20 STANDARD FOR THE INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTEC. NFPA 22 STANDARD FOR WATER TANKS FOR PRIVATE FIRE PROTECTION NFPA 24 STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS & THEIR APPURTENANCES NFPA 72 NATIONAL FIRE ALARM & SIGNALING CODE (CALIFORNIA AMENDED) NFPA 80 STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES NFPA2001 STANDARD ON CLEAN AGENT FIRE EXTINGUISHING SYSTEMS UL 300 STANDARD FOR FIRE TESTING OF FIRE EXTINGUISHING SYSTEMS FOR PROTECTION OF COMMERCIAL COOKING EQUIPMENT UL 464 AUDIBLE SIGNALING DEVICES FOR FIRE ALARM & SIGNALING SYSTEMS INCLUDING ACCESSORIES UL 521 STANDARD FOR HEAT DETECTORS FOR FIRE PROTECTIVE SIGNALING SYSTEMS NFPA 1971 STANDARD FOR SIGNALING DEVICES FOR TE HEARING IMPAIRED ICC 300 ICC STANDARDS ON BLEACHERS, FOLDING AND TELESCOPING SEATING AND GRAND STANDS
2016 2013 2013 2013
EDITION EDITION EDITION EDITION
2016 EDITION 2013 EDITION 2016 EDITION 2016 2016 2015 2005
EDITION EDITION EDITION (R2010)
2003 EDITION
1999 EDITION 2002 EDITION 2012 EDITION
FOR A COMPLETE LIST OF APPLICABLE NFPA STANDARDS REFER TO 2016 CBC (SFM) CHAPTER 35 & CA FIRE CODE CHAPTER 80. SEE CA BUILDING CODE, CHAPTER 35, FOR STATE OF CALIFORNIA AMENDMENTS TO NFA STANDARDS. *ALL PARTS OF THE 2016 CA BUILDING CODE BECOME EFFECTIVE JANUARY 1, 2017 EXCEPT THE EFFECTIVE DATE FOR THE USE OF THE 2016 AND THE EFFECTIVE DATE FOR THE USE OF THE CA. ADMINISTRATIVE CODE (TITLE 24, PART 1, CHAPTER 4) IS JANUARY 20, 2016.
DSA File No: IDENTIFICATION STAMP DIV OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES
04-116805 AC
FLS
SS
A SED RCH I EN RUH ID
N
AU
EACH ELECTRIC ELECTRIC WATER COOLER ELEVATION ENCLOSURE EQUAL EQUIPMENT EXISTING EXPANSION/EXPOSED EXPANSION JOINT EACH WAY EXTERIOR
H HDW HORIZ HR HT
RADIUS/RISER ROOF DRAIN REFERENCE REINFORCED REQUIRED ROUGH OPENING REQUIREMENT RESILIENT BASE RUBBER TREAD RAIN WATER LEADER
10.
ADDITION OF SITE WORK ALONG THE SOUTH AND WEST SIDE OF THE NEW BUILDING
SHEET NUMBER
SHEET NAME
No. C-20662 Exp. 3-31-19
AT
EA ELEC EWC ELEV ENCL EQ EQUIP (E) EXP EJ EW EXT
GA GAUGE GALV GALVANIZED GL GLASS GLU LAM GLUE LAMINATED GB GRAB BAR GPL GYPSUM PLASTER GWB GYPSUM WALLBOARD GWW WATER RESISTANT GWB GC GENERAL CONTRACTOR
R RD REF REINF REQD RO RQMT RSLB RT RWL
ALL WORK SHALL CONFORM TO TITLE 24, CALIFORNIA CODE OF REGULATIONS (C.C.R.) AND SECTION 4-333.
2.
SHEET NUMBER
ST
DWGS
DEMOUNTABLE PARTITION DETAIL DIMENSION DOOR DOOR FRAME DOOR LOUVER DOWN DOWN SPOUT DRINKING FOUNTAIN DIVISION OF STATE ARCHITECT DRAWINGS
FIRE EXTINGUISER CABINET FIRE HOSE CABINET FIREPROOF/FIREPROOFING FLOOR DRAIN FLOOR FURNISH/FURNITURE
9.
CONSTRUCTION OF NEW 19,496 SQ. FT. MULTI PURPOSE BUILDING.
* CT TE
DP DET DIM DR DRF DL DN DS DF DSA
FEC FHC FRPF FD FLR FURN
CONTRACTOR WILL BE REQUIRED TO PROVIDE AND INSTALL ALL EQUIPMENT AND RELATED ITEMS AS SHOWN IN THESE DOCUMENTS AND AS SPECIFIED. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO BID AND TO DETERMINE THE WORK NECESSARY TO COMPLETE THE PROJECT.
1.
E
IA
Structural KNA 9931 Muirlands Boulevard Irvine, Ca 92618 Phone: 949.462.3200 Contact: Jason Smith jsmith@knaconsulting.com
WHILE SCHOOL IS IN SESSION, CONSTRUCTION CREW SHALL ONLY OCCUPY SPACES RELATED TO THE WORK AND SHALL MINIMIZE DISRUPTION TO STUDENTS AND STAFF.
RN
Landscape MM+LA Associates 1982 White Birch Drive Vista, CA 92081 Phone: 760.525.2343 Contact: Brandt Maughan bmaughan@mmlandarc.com
1.
SHEET INDEX NOTE: EACH BIDDER SHALL EXAMINE THE DRAWINGS OF CONSTRUCTION DOCUMENTS TO DETERMINE THAT ALL SHOWN ON THE SHEET INDEX ARE INCLUDED WITH EACH SET RECEIVED. THE FAILURE OF ANY BIDDER TO EXAMINE OR RECEIVE ANY PART OF THE CONSTRUCTIO DOCUMENTS INDICATED ON THE INDEX SHALL NOT RELIEVE THE BIDDER FROM THEN OBLIGATION OF THESE DOCUMENTS.
L IC
Civil Epic Engineers 101 E. Redlands Blvd. Suite 146 Redlands, CA 92373 Phone: 909.792.5969 Contact: Chad Burian chad@epicre.com
Specifications Architectural Specifications, Inc. 190 Avocado Street Encinitas, CA, 92024 Phone: 760.271.3787 Contact: Helga Brown archspecs@mac.com
SHEET INDEX
DA V
Architect Ruhnau Ruhnau Clarke 5751 Palmer Way, Suite C Carlsbad CA 92010 Phone: 760.438.5899 Contact: Jason Villoria jvilloria@rrcarch.con Contact: David Ruhnau druhnau@rrcarch.com
Owner San Marcos Unified School District 255 Pico Avenue, Suite 250 Phone: 760.752.1299 Contact: Tova Corman
SCOPE OF WORK
GENERAL NOTES
*
CONTACT LIST
(951) 684 4664 / 5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010(760) 438 5899
NORTH
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
OF
CA L I
FO
DATE STAMPS
GENERAL NOTES, EXAMPLE DSA 103 FORM PLANS, SECTIONS & DETAILS
DEFERRED SUBMITTALS
1.
TELESCOPIC BLEACHER SEATING
2.
BASKETBALL STANDARDS
BRANDING
ALVIN DUNN K-8 SCHOOL PHASE 3 - BUILDING C 3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
RRCARCH.COM
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
(951) 684 4664 /
5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010 (760) 438 5899
TITLE SHEET
T1 1-84-28E
GENERAL NOTES
2
1
4
2
1
A1_5.1
A1_5.1
A1_5.1
3
4
6
8
10
13
14
16
15
1.
VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION.
2.
ALL DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF COLUMN OR EDGE OF SLAB, U.N.O.
3.
SEE SHEET AD1.1 FOR WALL TYPE INFORMATION.
4.
PROVIDE R-19 BATT INSULATION AT ALL EXTERIOR WALLS, U.N.O. GYPSUM BOARD AND INSULATION SHALL EXTEND FULL HEIGHT OF WALL TO UNDERSIDE OF ROOF STRUCTURE.
5.
PROVIDE STUD BRACING AND SUPPORT FOR ALL WALL MOUNTED FIXTURES AND ACCESSORIES. PER DETAIL 18/S0.9
6.
SEE SHEET A1_8.1 FOR DOOR AND WINDOW INFORMATION
7.
SET DOORS ADJACENT TO WALLS A MIN. OF 4" AWAY FROM WALL, PER DETAIL 7/AD5.1, U.N.O.
170' - 8"
7' - 4"
26' - 0"
25' - 8"
18' - 4"
26' - 0"
19' - 0"
14' - 4"
14' - 4"
17' - 8"
2' - 0"
1 A1_7.5
A
A IDF C106
A1_9.3 5' - 0"
5' - 0"
12' - 3 3/4"
3' - 0"
C100
C 2' - 0"
12' - 0" 4
C103A
VESTIBULE C100
2
C103B
MEN 1 C104 A1_7.5 3
WOMEN 1 C105 A1_7.5 3
4
2
2
C125D FSA
LOBBY
C104
CUSTODIAL STORAGE 106B
C105
D
C103 4' - 8"
C106
C L
C103C
1' - 8"
9' - 4"
9' - 4"
C
DN
S
48" MIN
C107A
CANOPY ABOVE
INSTRUMENT STORAGE 1 C110 4 2 A1_7.6 3
13' - 6 1/4"
OFF
E 12" CLR
35' - 0 1/4"
49' - 0"
C L
3 A1_5.1
DISPLAY CABINET
OFF
SEMI-RECESSED FIRE EXTINGUISHER CABINET, SEE SHEETS AS-0.2 FOR ALL LOCATIONS, PER DETAIL 1/AD7.1 LOCKER ROOM BENCH DRYER (CFCI) ALL CONTROLS TO BE AT FRON OF FRONT LOAD APPLIANCES WASHER (CFCI) ALL CONTROLS TO BE AT FRON OF FRONT LOAD APPLIANCES LOCKERS
10.514 11.213 11.214 11.651
C L
14' - 4"
19' - 0"
BATTERY STORAGE C150
10.441
C
A1_9.3
OFF
KEYNOTES
C L
C125C
10.441
9' - 8"
1
7' - 8"
B
2' - 8"
7' - 8"
5' - 0"
1 A1_7.2
LEGEND
DN
48" MIN
C
12" CLR
A1_7.2
S S
COMPACTING MACHINE
2' - 4"
6
C111A
C L CMU WALL (PER UL DES. U905, ALL 8" SOLID GROUTED ARE 2 HOUR FIRE RATED).
21' - 1 1/2"
OFF
GYM 1 C101 A1_7.7 3
16' - 10"
C
ELECTRICAL/ DATA C138
C137
12' - 6"
A1_7.1
C133B
132' - 8"
1 A1_5.2
C
1
S
C107B FIRE RATED WALL , PER PLAN METAL STUDS WALL, PER PLAN
BAND (ELEVATED 36" ABOVE GYM FLOOR) 1 C111 4 2 A1_7.6 3
2
BASKETBALL COURT
A
DOOR TAG, SEE SHEET A1-8.1 FOR DOOR SCHEDULE AND DOOR TYPES
101 1 1t
A1_5.2
WINDOW TAG, SEE SHEET A1-8.1 FOR WINDOW TYPES
WALL TAG, SEE SHEET AD1.1 FOR WALL TYPE DISCRIPTIONS STUD SIZE
M-#
[No Slope]
143' - 4"
C138
82' - 0"
7' - 3 1/4"
OFF
F
CMU WALL WITH METAL STUD FURRING, PER WALL TYPE "D"
MPR STAGE (ELEVATED 36" ABOVE GYM FLOOR) 1 C107 4 2 A1_7.8 3
9' - 4"
60' - 8"
SERVICE YARD C141
DRY STOR. C137
WALL TYPE
2A 10 B\C SEMI-RECESSED FIRE EXTINGUISHER, PER DETAIL 1/ AD7.1
STAGE CURTAIN
A
WH
ROOF HATCH, ACCESS LADDER, PER DETAILS 3 & 7/AD3.1
C107C
CUSTODIAN/ WATER HEATER C140
C111B 8' - 11 1/2"
C114
S
PRACTICE C112
UP
PRACTICE C113
OFFICE C114
STAGE ACCESS
4
16' - 4"
CORRIDOR C115
19' - 2 3/4"
19' - 8 3/4"
C132A
9' - 7 1/4"
C125A
C124A
VESTIBULE C123
10.441
10.514 11.651
10.514
C126
CUSTODIAL STORAGE C116
C123
4
2
MPR STORAGE C131
3
GIRLS LOCKER ROOM C127
16' - 4"
C127
C116B
C119
BOYS LOCKER ROOM C119
11.213
C122
C130
C121
E 10.441
10.441
1' - 7 1/4"
C L
C L
D
D COACH'S OFFICE C129
2' - 8 3/4"
J KOC OFFICE C118
10.441
10.441
COACH'S OFFICE C122
C L
C125B
K
TOILET C121
12" CLR
C124B
C131B
C
C L
28' - 0"
CANOPY ABOVE
C L
5' - 4"
C L 25' - 8"
18' - 4"
2' - 4"
C L
C L
24' - 0"
8' - 4"
C L
6' - 0"
20' - 8"
L
C L
6' - 0"
04-116805
2' - 0"
34' - 8"
1
A1_7.4
A1_7.3
FLS
SS
ID
N
AT
AC
1
A SED RCH I EN RUH
No. C-20662 Exp. 3-31-19
ST
33' - 4"
2' - 4"
IDENTIFICATION STAMP DIV OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES
AU
2' - 0"
16' - 8"
DSA File No:
* CT TE
6' - 8"
6' - 0"
KEY PLAN
K
C118 10.441
2' - 0"
NORTH
TOILET C130
BLDG C
8' - 8"
C
C132C
C L
C117
2' - 0"
C132B
C133A
C129
BLDG B
11.214
A1_5.2
6' - 8"
SHOWER C120
C134
8' - 8"
LOCKER CALCS: 43 x 5 (STACKED)= 215 ASSIGNED 204 STANDARD 11 ACCESSIBLE (5%) 43 (FULL HEIGHT) DAY-USE LOCKERS
C120
SHOWER C128
W
OFFICE C134
C128
D
10' - 8 1/4"
LOCKER CALCS: 43 x 5 (STACKED)= 215 ASSIGNED 204 STANDARD 11 ACCESSIBLE (5%) 43 (FULL HEIGHT) DAY-USE LOCKERS
F
J
L
2
SPORTS STORAGE C117
G
19' - 8"
C L
C
A1_5.2
BOYS BATHROOM C124
48" MIN
30' - 4"
2
10.441
GIRLS BATHROOM C125
BLDG A
30' - 4"
19' - 7 1/2"
18" CLR
SPEED LINE 1 C132
H
C116A VESTIBULE C126
KITCHEN C133
C L
C115
C131A
8' - 4"
5' - 4"
C101
G
4' - 0"
C L
48 MIN
H
C L
C102
P.E. STORAGE C102
ANS
WALK-IN REF C135
5' - 4"
10' - 0"
10' - 3 3/4"
A1_7.5
E
OF
IA
C
RN
TOILET C139
L IC
C113
DA V
7' - 11 1/2"
12' - 3 3/4" B
C112 C139
9' - 0"
*
C140
10' - 7 1/2"
8' - 7 1/4"
12' - 2 1/4"
FREEZER C136
12' - 4 1/2"
43' - 8"
DN
CA L I
FO
DATE STAMPS
3
4
6
7
9
11
12
4
1
A1_5.1
A1_5.1
15
16
NORTH
1
BRANDING
ALVIN DUNN K-8 SCHOOL SCALE:
FLOOR PLAN RRC PROJECT No. : 1-84-28E 12/11/2017 4:47:52 PM DRAWN BY:
CHECKED BY:
1/8" = 1'-0"
1
3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
RRCARCH.COM
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
(951) 684 4664 /
5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010 (760) 438 5899
MPR FLOOR PLAN
A1_1.1 1-84-28E
GENERAL NOTES
2
1
4
2
A1_5.1
A1_5.1
3
4
6
8
10
13
14
15
16
1.
ALL LIGHT FIXTURES TO BE CENTERED IN SPACE, U.N.O.
2.
ALL CEILING HEIGHTS ARE RELATIVE TO THE FINISH FLOOR DIRECTLY BENEATH.
3.
ACOUSTICAL CEILING TILES AND GRID TO BE CENTERED IN ROOM. SEE SHEET AD4.1 FOR SUSPENDED CEILING SEISMIC BRACING DETAILS AND TRAPEZE DETAILS
4.
ALL EXPOSED STRUCTURE, INCLUDING MECHANICAL & PLUMBING EQUIPMENT TO BE PAINTED
5.
ALL MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT TO BE HELD AS TIGHT AS POSSIBLE TO CEILING STRUCTURE
6.
ALL CONDUIT IN EXPOSED AREAS WHERE CEILING STRUCTURE IS EXPOSED CAN ONLY PENETRATE WALLS AT ROOF / FLOOR DECK
7.
REFER TO ELECTRICAL & MECHANICAL DRAWINGS FOR CEILING COMPONENT CALLOUTS AND FIXTURE TYPES
8.
PAINT ALL SUPPLY & RETURNS OF ALL ACCENT PAINTED CEILING AREAS
26.540 TYP. EQ 6' - 6"
3' - 0"
EQ
EQ
2' - 9"
6' - 6"
EQ
A
A
6' - 0" EQ
EQ
OPEN TO STRUCTURE EQ
EQ
EQ
08.601 EQ EQ
EQ
FSA 106A
EQ
3' - 3"
3' - 3"
12' - 10"
12' - 10"
LOBBY C103
EQ
08.601 11.522 11.524 11.662 26.540 26.557
EQ
10' - 0" A.F.F.
CUSTODIAL STORAGE 106B
LEGEND
D
OPEN TO STRUCTURE
EQ
ROOF ACCESS HATCH, PER DETAIL 3/AD3.1 WALL MOUNTED PROJECTOR, SEE DETAIL REFER TO SPECS REAR PROJECTION SCREEN BASKETBALL EQUIPMENT WALL-MOUNTED LIGHT FIXTURE, PER ELECTRICAL, TYP. THEATRICAL LIGHTING
EQ
EQ
C
EQ
EQ
4' - 0"
4' - 0"
9' - 0" A.F.F. WOMEN C105
11.662
BATTERY STORAGE C150
KEYNOTES
IDF C106
4' - 3" 2' - 9"
EQ
EQ
EQ
5' - 0"
VESTIBULE C100
9' - 0" A.F.F. MEN C104
5' - 10"
5' - 10"
2' - 9"
C
EQ EQ
8' - 5"
EQ EQ
B
EQ EQ
EQ
EQ
2' - 0"
EQ
2 X 4 ACT TILE 3 EQ
EQ
5' - 0"
A1_5.1
EQ
5' - 0"
6' - 0"
E
GYP BOARD
11.662
2"
GALV. STEEL DECK
10' - 0" A.F.F.
EQ
12' - 0"
OPEN
5' - 10"
18' - 9 1/2"
11.662
EQ
EQ
6' - 0" EQ
15' - 7 3/4"
15' - 11"
LIGHT FIXTURES, PER ELECTRICAL DRAWINGS
OPEN TO STRUCTURE 11.522
4' - 0"
EQ
F
EQ
MPR STAGE (ELEVATED 36" ABOVE GYM FLOOR) C107
7' - 4 1/2"
3' - 4"
15' - 7 3/4"
EQ
15' - 7 3/4"
6' - 0"
13' - 9"
EQ
EQ
5' - 4"
94' - 0"
SERVICE YARD
ROOF ACCESS HATCH, PER DETAILS ON SHEET AD3.1
10' - 0" A.F.F.
1
EXIT SIGNAGE, PER ELECTRICAL DRAWINGS
1 GYM C101
A1_5.2
OPEN TO STRUCTURE
EQ. ELECTRICAL/ DATA C138
EQ
EQ
3' - 2"
EQ
EQ
EQ EQ
BLDG B
7' - 9 1/4"
NORTH
EQ
EQ.
EQ
2' - 9" EQ EQ
EQ
9' - 0" A.F.F. EQ
EQ
EQ
EQ EQ
EQ
K
DSA File No: IDENTIFICATION STAMP DIV OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES
L
19' - 4"
EQ
04-116805
EQ
FLS
ID
N
AT
AC
A SED RCH I EN RUH
No. C-20662 Exp. 3-31-19
ST
EQ
EQ
EQ
KEY PLAN AU
10' - 8"
9' - 0" A.F.F. 9' - 0" A.F.F.
EQ
J
SS
E
IA
EQ
TOILET C121
RN
EQ
BLDG C
KOC OFFICE C118
L IC
EQ
COACH'S OFFICE C122
4' - 8"
DA V
EQ
9' - 5"
OPEN TO STRUCTURE
* CT TE
L
EQ
EQ
1' - 8"
3' - 0"
EQ
EQ
9' - 0" A.F.F.
K
EQ
SPORTS STORAGE C117
A1_5.2
*
EQ
EQ
EQ
1' - 8"
EQ
EQ
EQ OPEN TO STRUCTURE
2
4' - 10"
EQ
2' - 9" COACH'S OFFICE C129
4' - 6"
EQ
3' - 0"
EQ
EQ
EQ
9' - 0" A.F.F.
EQ
BOYS LOCKER ROOM C119
SHOWER 9' - 0" A.F.F.
SHOWER
9' - 0" A.F.F. EQ
EQ
EQ
TOILET C130
EQ
9' - 10"
EQ
J
EQ
9' - 0" A.F.F.
EQ
EQ.
EQ
4' - 8"
EQ
OFFICE C134 9' - 0" A.F.F.
EQ
19' - 5 1/4"
A1_5.2
10' - 10"
EQ
2
BOYS BATHROOM C124 9' - 0" A.F.F.
5' - 0 3/4"
9' - 0" A.F.F.
GIRLS BATHROOM C125 9' - 0" A.F.F.
EQ
4' - 8 1/8"
EQ
H BLDG A
EQ
9' - 7" EQ
OPEN TO STRUCTURE
EQ
10' - 0" A.F.F. 4' - 6"
EQ
EQ
EQ.
4' - 8"
EQ
OPEN TO STRUCTURE
MPR STORAGE C131
EQ.
8' - 8 3/8"
EQ
CUSTODIAL STORAGE C116
EQ
VESTIBULE
EQ.
VESTIBULE
EQ
KITCHEN C133
EQ
6' - 0"
4' - 8"
H
EQ
4' - 4 1/2"
EQ
CORRIDOR C115 10' - 0" A.F.F.
EQ
OPEN TO STRUCTURE
EQ
EQ
OPEN TO STRUCTURE
G 2' - 4"
EQ
EQ
9' - 0" A.F.F.
9' - 0" A.F.F.
11.662 5' - 7"
WALK-IN REF C135
9' - 0" A.F.F.
EQ
P.E. STORAGE C102
VESTIBULE
4' - 8"
EQ
EQ
EQ
EQ
EQ
9' - 0" A.F.F.
OPEN TO STRUCTURE
10' - 0"
7' - 2"
13' - 0" A.F.F.
TOILET C139
EQ
OPEN TO STRUCTURE
CUSTODIAN/ WATER HEATER C140
EQ
EQ
EQ
FOR SERVICES WITHIN THE CEILING, REFER TO NOTE #7 ON 3 / AD4.1 FOR LOCATION OF SLIP / EXPANSION JOINTS IN CORRIDORS, REFER TO DETAILS 19/AD4.1 AND 22/AD4.1
10' - 0"
8' - 0"
13' - 0"
FREEZER C136
1. 2.
11.662
4' - 0"
OPEN TO STRUCTURE
11.662
NOTE: 26.557
11.524
6' - 0"
OPEN TO STRUCTURE
18' - 9 1/2"
EQ
AIR DIFFUSERS, PER MECHANICAL DRAWINGS 4' - 0"
EQ
29' - 1 3/4"
A1_5.2
EQ
8' - 4 3/4" DRY STOR. C137
EQ
19' - 5 1/4"
EQ
EQ.
EQ
EQ
EQ
26.557
OF
CA L I
FO
DATE STAMPS
1
3
4
6
7
9
11
12
15
16
4
NORTH
A1_5.1
BRANDING
ALVIN DUNN K-8 SCHOOL SCALE:
REFLECTED CEILING PLAN - LEVEL 1 RRC PROJECT No. : 1-84-28E 12/12/2017 6:36:30 PM DRAWN BY:
CHECKED BY:
1/8" = 1'-0"
1
3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
RRCARCH.COM
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
(951) 684 4664 /
5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010 (760) 438 5899
MPR REFLECTED CEILING PLAN
A1_2.1 1-84-28E
GENERAL NOTES
2
1
3
4
6
8
10
13
14
15
16
1.
SEE DETAIL 4/AD3.1 FOR TYPICAL ROOF ASSEMBLY.
2.
FOR PIPE VENT PENETRATIONS THROUGH ROOF, REFER TO DETAIL 8 & 17/AD3.1 FOR TYP. INFO.
3.
ALL CRICKETS SHALL BE SHAPED WITH PLYWOOD WITH A MIN. 1.5% SLOPE TO ROOF AND OVERFLOW DRAINS.
4.
PROVIDE 36" WIDE CONTINUOUS WALKWAY TREAD FROM THE LANDING OF EACH ROOF ACCESS HATCH TO EACH MECHANCIAL UNIT. TREAD AT EACH UNIT TO SURROUND PERIMETER
5.
AT MECHANICAL EQUIPMENT, REFER TO DETAIL 14/AD3.1 FOR ROOF CURB
KEYNOTES
C L 22' - 7 5/8"
32' - 4"
13' - 0 3/8"
34' - 11 3/4"
30' - 5 7/8"
14' - 1 1/4"
A 20' - 9 5/8"
20' - 9 5/8"
T.O.SH.
T.O.M.
T.O.M.
31' - 8"
5/8" / 1'-0"
C
4" 1/
13' - 6 3/8"
1
T.O.SH.
A
14' - 1 1/4"
13' - 7 3/8"
13' - 5 7/8"
12' - 2"
B
13' - 6 3/8"
10'-0" MIN.
AD3.1
C
" '-0 /1
25' - 7 1/8"
3 AD3.1
26' - 1 1/8"
38' - 8 1/2"
"
1'0"
0 1'-
1/4 "/
3/8" / 1'-0"
1/8 "/1 '-0"
" '-0 /1 " 8 5/
1'0"
D
-0"
"/ 7 /8
TYP.
10
5/ 8" /
AD3.1
/ 1'
25' - 5 5/8"
'-0" "/1 1/8
29' - 3 1/2"
0" 1'/ 2" 1/
20
" 1/8
26' - 0 1/8"
TYP.
1/4" / 1'-0"
1/4" / 1'-0" 3/8" / 1'-0"
AD3.1
LEGEND
13' - 10 1/8"
13' - 10 1/8"
E
13' - 4"
5/8" / 1'-0"
1' -0 "
29' - 9 7/8"
28' - 6"
3/ 8" /
1/2" / 1'-0"
5/8" / 1'-0"
4' - 4 7/8"
" -0 1'
" -0 1'
"
/1 '-0 "
" 1' -0
C L
G
4' - 0"
1/2" / 1'-0"
2' - 0"
25' - 9 1/8"
C L
26' - 5 1/8"
H
22' - 11 1/4"
ANS
25' - 9 1/8"
BLDG A
BLDG B
1/2" / 1'-0"
35' - 7 3/4"
13' - 8"
23.810 TYP.
4' - 0"
16' - 10"
" -0 1' / " /8 5/8" / 1'-0"
1/2" / 1'0"
15' - 5 3/8"
8" 3/
" '-0 1 /
3
UP
3/ 8" /
" 1'0 3/4 "/
23' - 8 3/8"
0" 1'-
68' - 0"
22.145 TYP.
07.713
20' - 10 1/8"
"/ 1/4
31' - 10 5/8"
C L
25' - 9 1/8"
HVAC SYSTEM PER MECHANICAL DRAWINGS
C L
24' - 11 7/8"
C L
C L
07.511
16' - 0"
HVAC SYSTEM PER MECHANICAL DRAWINGS
/ 8" 3/
/ 8" 3/
1/2" / 1'-0"
WH
H
9 1/4"
C L
" 1'0 3/ 8" /
33' - 1 1/2"
07.511
25' - 6 7/8"
13' - 11 5/8"
13' - 4"
1/2" / 1'-0"
ROOF DRAIN, PER DETAIL
0 1'-
1/4 "
" -0 1' / " /8
ROOF CRICKET. PROVIDE MIN. 2% (1:50) SLOPE.
5/8" / 1'-0"
07.511
/ 8" 3/
"/ 1/4
12' - 0"
16' - 8 3/8" 31' - 6"
1'-0 " 1/4 "/
3/8" / 1'-0"
26' - 4 1/4"
1/2" / 1'-0"
1/4" / 1'-0"
24' - 0" 9' - 0"
3
C L 0" 1'-
" -0 1'
23.810
25' - 0 3/4"
1'-0 "
/ 8" 3/
1/2" / 1'-0"
5/8" / 1'-0"
8"
3/8 "/
"
07.713
" 1'-0
3/
'-0 /1
0" 1'-
" -0 1'
"/ 1/4
0" 3/8" / 1'-
"/ 1/4
ROOF ACCESS HATCH, PER DETAIL
C L
25' - 4 3/8"
C L
EQ
C L
1/2" / 1'-0"
18' - 0"
C L EQ
ROOF PROTECTION PAD, PER SPECIFICATIONS. PROTECTION PADS TO BE 36" MIN. IN WIDTH.
05.530
24' - 11 5/8"
12' - 10"
F
/ 8" 3/
TYP.
C L
5/8" / 1'-0"
C L
C L
5/8" / 1'-0"
4' - 0"
25' - 1 1/8"
13 AD3.1
05.530 MECHANICAL SCREEN, PER DETAIL 1/AD3.2. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION 07.511 SINGLE PLY ROOF MEMBRANE OVER 7" OF RIGID INSULATION, SEE DETAIL 4/AD3.1 FOR ROOF ASSEMBLY 07.713 MANUFACTURED SCUPPER 22.145 ROOF DRAIN, PER DETAILS 13 & 16/AD3.1 23.810 HVAC EQUIPMENT, PER MECHANICAL DRAWINGS
35' - 10"
22' - 0"
12' - 11"
2' - 0"
C L 20'-6"
C L
NORTH
3/8" / 1'-0"
8"
"
KEY PLAN DSA File No: IDENTIFICATION STAMP DIV OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES
39' - 8 3/8"
26' - 11 5/8"
22' - 8"
9' - 0 3/8"
8' - 11 5/8"
20' - 8"
8' - 11 5/8"
9' - 8 3/8"
FLS
SS
22' - 0"
AT
AC
2' - 0"
N
No. C-20662 Exp. 3-31-19
ST
04-116805
ID
AU
L
A SED RCH I EN RUH
* CT TE
L
K 3' - 11 5/8"
K
E
OF
IA
C L
RN
0" 1'-
J 0 1'-
"/ 7/8
3/8" / 1'-0"
" / 1'-0 1/8"
C L
/ 2" 1/
8' - 0"
J
BLDG C
L IC
"
1'-0 "
1'0"
DA V
0 1'-
1/4 "/
3/8 "/
0" 1'/ 8" 3/
07.511
*
10"
"/
10' - 2"
1'0
3/4
5 /8 "/
05.530
1'-0" 1/8" /
24' - 4 3/4"
C L
11' - 0 3/4"
1'-0"
"
1/8" /
CA L I
FO
DATE STAMPS
3
4
6
7
9
11
12
15
16
NORTH
1
BRANDING
ALVIN DUNN K-8 SCHOOL SCALE:
ROOF PLAN RRC PROJECT No. : 1-84-28E 12/11/2017 4:48:07 PM DRAWN BY:
CHECKED BY:
1/8" = 1'-0"
1
3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
RRCARCH.COM
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
(951) 684 4664 /
5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010 (760) 438 5899
MPR ROOF PLAN
A1_3.1 1-84-28E
GENERAL NOTES
1 A1_5.1
1.
SLAB ON GRADE: 0'-0" = GLOBAL ELEVATION:78.42' ABOVE SEA LEVEL
2
1
2
4
3
4
A1_5.1
6
7
8
9
A1_5.1
10 11
12 13
14
15 16
T.O. GYM PARAPET 29' - 4"
05.530 TYP T.O. STAGE PARAPET 26' - 8"
T. O MECHANICAL SCREEN 23' - 4"
T.O. BAND PARAPET 20' - 8" T. O. PARAPET 19' - 4"
T.O. KITCHEN PARAPET 16' - 8"
T.O. LOWER PARAPET 18' - 0"
1' - 8" 27.210 TYP
2' - 0" 12' - 0"
12' - 0" TYP.
7' - 8"
7' - 7"
7' - 8" TYP.
3' - 0"
2' - 0"
12' - 0" TYP.
1' - 8"
2' - 0"
KEYNOTES
STAGE LEVEL 3' - 0"
FLOOR PLAN 0"
05.530
FLOOR PLAN 0" 27.350 TYP.
27.210
27.410 TYP.
28.460 TYP.
27.350
22.471
26.540 TYP.
26.540
28.460
26.540
27.350
SCALE:
SOUTH ELEVATION
1/8" = 1'-0" REF.:
/
1
08.121 10.113 10.734 22.471 26.540 27.210 27.350 27.410 28.460
16 15
14
13 12
11 10
9
8
7
6
4
3
1
2
4
A1_5.1
A1_5.1
A1_5.1
2
MECHANICAL SCREEN, PER DETAIL 1/AD3.2. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION HOLLOW METAL DOOR AND FRAME, PER DOOR SCHEDULE ON SHEET A1_8.1 ELECTRONIC SCHOOL MARQUEE LETTER MARQUEE DRINKING FOUNTAIN WALL-MOUNTED LIGHT FIXTURE, PER ELECTRICAL, TYP. WIRELESS ACCESS POINT, PER ELECTRICAL DRAWINGS INTERCOM SPEAKERS, PER ELECTRICAL DRAWINGS 42" FLAT SCREEN TELEVSION, MOUNTED TO EXTERIOR WALL IN WEATHERPROOF ENCLOSURE; PROVIDE POWER AND DATA FIRE ALARM SPEAKER, PER ELECTRICAL DRAWINGS
1
FINISH LEGEND
10.113
T.O. GYM PARAPET 29' - 4"
26.540 T.O. STAGE PARAPET 26' - 8"
CMU 1: OCRO - BLOCK 50 - SHOT BLAST
T. O MECHANICAL SCREEN 23' - 4"
10.734
T.O. PARAPET 21' - 4"
T.O. BAND PARAPET 20' - 8"
CMU 2: ORCO - SIENNA MISSION - SPLIT FACE
T.O. KITCHEN PARAPET 16' - 8"
CMU 3: ORCO - BLACK 250 - BURNISHED
T.O. WALL 8' - 8" 10' - 0"
11' - 4"
T.O. WALL 8' - 0"
FLOOR PLAN 0"
FLOOR PLAN 0" 27.350
28.460
26.540
28.460
26.540
27.350 SCALE:
N ELEVATION L
K
J
H
G
F
E
D
2
1
3
A1_5.2
A1_5.2
A1_5.1
26.540
26.540
26.540
05.530
C
B
1/8" = 1'-0" REF.:
/
2
A
27.210 T.O. GYM PARAPET 29' - 4" T.O. STAGE PARAPET 26' - 8" T.O. PARAPET 21' - 4"
T. O MECHANICAL SCREEN 23' - 4" 26.540
T. O. PARAPET 19' - 4"
T.O. BAND PARAPET 20' - 8"
T.O. LOWER PARAPET 18' - 0"
26.540 1' - 8"
BLDG A
2' - 0"
11' - 4"
10' - 0"
7' - 4"
T.O. WALL 8' - 8"
FLOOR PLAN 0" 08.121 TYP. 27.350
28.460
BLDG B
FLOOR PLAN 0" 27.350
SCALE:
A
B
C
D
E
F
G
H
J
3
1
2
A1_5.1
A1_5.2
A1_5.2
K
1/8" = 1'-0" REF.:
/
3
BLDG C
NORTH
EAST ELEVATION L
KEY PLAN DSA File No:
T. O. PARAPET 19' - 4"
No. C-20662 Exp. 3-31-19
SS
E
IA
DA V
*
N
RN
FLS
ID
AT
AC
T.O. PARAPET 21' - 4"
A SED RCH I EN RUH
AU
04-116805
T. O MECHANICAL SCREEN 23' - 4"
ST
8' - 0"
05.530
L IC
IDENTIFICATION STAMP DIV OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES
* CT TE
T.O. GYM PARAPET 29' - 4"
OF
CA L I
FO
DATE STAMPS
T.O. LOWER PARAPET 18' - 0" T.O. KITCHEN PARAPET 16' - 8"
T.O. WALL 8' - 8"
3' - 4"
T.O. WALL 8' - 0"
22.471 FLOOR PLAN 0"
FLOOR PLAN 0" 26.540
26.540
28.460
26.540
BRANDING
27.350
ALVIN DUNN K-8 SCHOOL SCALE:
WEST ELEVATION RRC PROJECT No. : 1-84-28E 12/12/2017 7:10:52 PM DRAWN BY:
CHECKED BY:
1/8" = 1'-0" REF.:
/
4
3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
RRCARCH.COM
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
(951) 684 4664 /
5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010 (760) 438 5899
MPR BUILDING ELEVATIONS
A1_4.1 1-84-28E
GENERAL NOTES L
H
G
SLAB ON GRADE: 0'-0" = GLOBAL ELEVATION: 78.42'
2.
VERIFY ALL EXTERIOR ROOF OPENINGS & VENTS WITH MECHANICAL, ELECTRICAL, STRUCTURAL & PLUMBING DRAWINGS. SEE DETAILS 8, 17 & 18/AD3.1 FOR TYPICAL ROOF VENT PENETRATION DETAIL.
3.
PROVIDE R-38 RIGID INSULATION OVER (STRUCTUE TYPE). SEE DETAIL 4/AD3.1 FOR TYPICAL ROOF CONSTRUCTION ASSEMBLY.
4.
PROVIDE R-19 BATT INSULATION AT ALL EXTERIOR WALLS, U.N.O. GYPSUM BOARD AND INSULATION SHALL EXTEND FULL HEIGHT OF WALL TO UNDERSIDE OF ROOF STRUCTURE
5.
ALL EXPOSED STRUCTURE, INCLUDING MECHANICAL & PLUMBING EQUIPMENT TO BE PAINTED
E
2
1
3
A1_5.2
A1_5.2
A1_5.1
4
5 23' - 6" T.O. STEEL
1.
05.301
A1_6.2
07.511
A1_6.2
T.O. GYM PARAPET 29' - 4" 16' - 2" T.O. STEEL
T.O. STAGE PARAPET 26' - 8"
6 A1_6.2
T. O. PARAPET 19' - 4" 12' - 9" T.O. STEEL 13' - 2" T.O. STEEL
BOYS LOCKER ROOM C119
MPR STAGE (ELEVATED 36" ABOVE GYM FLOOR) C107
LOBBY C103
KEYNOTES STAGE LEVEL 3' - 0"
FLOOR PLAN 0"
05.301 05.530
FLOOR PLAN 0"
METAL ROOF DECK, PER STRUCTURAL DRAWINGS MECHANICAL SCREEN, PER DETAIL 1/AD3.2. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION SINGLE PLY ROOF MEMBRANE OVER 7" OF RIGID INSULATION, SEE DETAIL 4/AD3.1 FOR ROOF ASSEMBLY
07.511
SCALE:
1/A1_5.1
1/8" = 1'-0" REF.:
1 /A1_1.1
1
LEGEND 8
14
E
C
2
1
3
A1_5.1
A1_5.1
A1_5.1
4 2
B
A
Sim
A1_6.2
A1_6.2 05.301 05.301
07.511
T.O. GYM PARAPET 29' - 4"
T.O. GYM PARAPET 29' - 4" 07.511
T.O. STAGE PARAPET 26' - 8"
24' - 3" T.O. STEEL
1 1
A1_6.3
A1_6.2
13' - 4" T.O. STEEL MPR STAGE (ELEVATED 36" ABOVE GYM FLOOR) C107
T.O. WALL 8' - 8" GYM C101
LOBBY C103
LOBBY C103 STAGE LEVEL 3' - 0"
FLOOR PLAN 0"
FLOOR PLAN 0"
FLOOR PLAN 0"
FLOOR PLAN 0"
SCALE:
4/A1_5.1 J
1 /A1_1.1
3
2/A1_5.1
H
B
2
1
A1_5.2
A1_5.2
1/8" = 1'-0" REF.:
1 /A1_1.1
2
A BLDG B
L
1/8" = 1'-0" REF.:
BLDG A
SCALE:
BLDG C
4 3
A1_6.3
07.511
NORTH
A1_6.3 05.301 05.301
DSA File No:
04-116805
T.O. PARAPET 21' - 4"
FLS
AT
AC
T.O. KITCHEN PARAPET 16' -14' 8" - 9" T.O. STEEL
N
No. C-20662 Exp. 3-31-19
ST
19' - 6" T.O. STEEL
ID
AU
07.511
A SED RCH I EN RUH
SS
E
OF
IA
05.301
* CT TE
IDENTIFICATION STAMP DIV OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES
T.O. STEEL 16' - 0"
RN
A1_6.3
L IC
07.511
A1_6.4
DA V
1
KEY PLAN
T.O. GYM PARAPET 29' - 4"
2
*
05.530
CA L I
FO
DATE STAMPS
KITCHEN C133
KITCHEN C133
GYM C101
VESTIBULE C100
OPEN TO VEST FLOOR PLAN 0"
FLOOR PLAN 0"
BRANDING
ALVIN DUNN K-8 SCHOOL SCALE:
3/A1_5.1 RRC PROJECT No. : 1-84-28E 12/11/2017 4:48:35 PM DRAWN BY:
CHECKED BY:
1/8" = 1'-0" REF.:
1 /A1_1.1
4
3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
RRCARCH.COM
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
(951) 684 4664 /
5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010 (760) 438 5899
WALL SECTIONS BUILDING SECTIONS
A1_5.1 1-84-28E
GENERAL NOTES
1
2
3
4
6
13
8 2
1
A1_5.1
A1_5.1
1.
SLAB ON GRADE: 0'-0" = GLOBAL ELEVATION: 78.42'
2.
VERIFY ALL EXTERIOR ROOF OPENINGS & VENTS WITH MECHANICAL, ELECTRICAL, STRUCTURAL & PLUMBING DRAWINGS. SEE DETAILS 8, 17 & 18/AD3.1 FOR TYPICAL ROOF VENT PENETRATION DETAIL.
3.
PROVIDE R-38 RIGID INSULATION OVER (STRUCTUE TYPE). SEE DETAIL 4/AD3.1 FOR TYPICAL ROOF CONSTRUCTION ASSEMBLY.
4.
PROVIDE R-19 BATT INSULATION AT ALL EXTERIOR WALLS, U.N.O. GYPSUM BOARD AND INSULATION SHALL EXTEND FULL HEIGHT OF WALL TO UNDERSIDE OF ROOF STRUCTURE
5.
ALL EXPOSED STRUCTURE, INCLUDING MECHANICAL & PLUMBING EQUIPMENT TO BE PAINTED
15 16
KEYNOTES
5
4
A1_6.1
05.301 05.530
A1_6.1 05.301
07.511
07.511
3
05.301
07.511
05.301 07.511
A1_6.1
25' - 8" T.O. STEEL
2 T.O. GYM PARAPET 29' - 4"
METAL ROOF DECK, PER STRUCTURAL DRAWINGS MECHANICAL SCREEN, PER DETAIL 1/AD3.2. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION SINGLE PLY ROOF MEMBRANE OVER 7" OF RIGID INSULATION, SEE DETAIL 4/AD3.1 FOR ROOF ASSEMBLY
A1_6.1
23' - 4" T.O. STEEL
T.O. STAGE PARAPET 26' - 8"
24' - 4" T.O. STEEL
T.O. BAND PARAPET 20' - 8"
SERVICE YARD GYM C101
Theatrical Lighting Bar Height
20' - 4"
17' - 4" T.O. STEEL
MPR STAGE (ELEVATED 36" ABOVE GYM FLOOR) C107
STAGE LEVEL 3' - 0"
FLOOR PLAN 0"
FLOOR PLAN 0"
LEGEND
SCALE:
1/A1_5.2
1
3
4
6
8 1
A1_5.1
A1_5.1
REF.:
1 /A1_1.1
1
15 16
13
4
1/8" = 1'-0"
BLDG B
BLDG A
BLDG C 07.511
05.301
05.530 NORTH
1 A1_6.1
T.O. GYM PARAPET 29' - 4" 1
Sim T.O. STAGE PARAPET 26' - 8"
A1_6.1
KEY PLAN
T. O MECHANICAL SCREEN 23' - 4"
DSA File No:
RN
SS
E
OF
IA
L IC
DA V
AT
FLS
N
No. C-20662 Exp. 3-31-19
ST
AC
*
04-116805
ID
AU
T.O. LOWER PARAPET 18' - 0"
A SED RCH I EN RUH
* CT TE
IDENTIFICATION STAMP DIV OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES
CA L I
FO
DATE STAMPS
KITCHEN C133
MPR STORAGE C131
BOYS LOCKER ROOM C119
SPORTS STORAGE C117
FLOOR PLAN 0"
FLOOR PLAN 0"
BRANDING
ALVIN DUNN K-8 SCHOOL SCALE:
2/A1_5.2 RRC PROJECT No. : 1-84-28E 12/11/2017 4:48:45 PM DRAWN BY:
CHECKED BY:
1/8" = 1'-0" REF.:
1 /A1_1.1
2
3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
RRCARCH.COM
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
(951) 684 4664 /
5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010 (760) 438 5899
BUILDING SECTIONS
A1_5.2 1-84-28E
GENERAL NOTES
3
8
13
15
16
15
1.
SLAB ON GRADE: 0'-0" = GLOBAL ELEVATION: 78.42'
2.
VERIFY ALL EXTERIOR ROOF OPENINGS & VENTS WITH MECHANICAL, ELECTRICAL, STRUCTURAL & PLUMBING DRAWINGS. SEE DETAILS 8, 17 & 18/AD3.1 FOR TYPICAL ROOF VENT PENETRATION DETAIL.
3.
PROVIDE R-38 RIGID INSULATION OVER (STRUCTUE TYPE). SEE DETAIL 4/AD3.1 FOR TYPICAL ROOF CONSTRUCTION ASSEMBLY.
4.
PROVIDE R-19 BATT INSULATION AT ALL EXTERIOR WALLS, U.N.O. GYPSUM BOARD AND INSULATION SHALL EXTEND FULL HEIGHT OF WALL TO UNDERSIDE OF ROOF STRUCTURE
5.
ALL EXPOSED STRUCTURE, INCLUDING MECHANICAL & PLUMBING EQUIPMENT TO BE PAINTED
16
1 AD3.1
1 AD3.1 05.301
07.511
T.O. GYM PARAPET 29' - 4"
KEYNOTES
T.O. GYM PARAPET 29' - 4"
07.511 07.511
05.301
AD3.1
05.301
T.O. STAGE PARAPET 26' - 8"
07.511
1
03.355 04.220 05.301 05.401 07.511
1
07.950 09.210 09.530
T.O. STAGE PARAPET 26' - 8"
AD3.1 05.301
04.220
24' - 8" T.O. STEEL 24' - 4" T.O. STEEL
CONCRETE SLAB ON GRADE, PER STRUCTURAL DRAWINGS CONCRETE UNIT MASONRY, PER PLAN METAL ROOF DECK, PER STRUCTURAL DRAWINGS METAL STUD FRAMING SINGLE PLY ROOF MEMBRANE OVER 7" OF RIGID INSULATION, SEE DETAIL 4/AD3.1 FOR ROOF ASSEMBLY EXPANSION CONTROL JOINT, PER DETAIL 12/S0.5 5/8" GYPSUM BOARD PER WALL TYPE, WALL FINISH PER FINISH SCHEDULE, SEE SHEET A1_9.1 ACOUSTICAL CEILING SUSPENSION ASSEMBLY
10
24' - 3" T.O. STEEL
AD3.1 10 23' - 4" T.O. STEEL
AD3.1
1 07.511
05.301
07.511
05.301
AD3.1
04.220
T.O. BAND PARAPET 20' - 8"
T.O. BAND PARAPET 20' - 8"
10 AD3.1 1 AD3.1
18' - 8" T.O. STEEL
T.O. LOWER PARAPET 18' - 0" 17' - 2" T.O. STEEL
9 AD3.1
15' - 4" T.O. STEEL
22 AD5.1
05.401
15' - 0"
09.530
09.530
MPR STAGE (ELEVATED 36" ABOVE GYM FLOOR) C107
GYM C101
04.220 TYP.
SPORTS STORAGE C117
04.220
BLDG A 04.220 MPR STAGE (ELEVATED 36" ABOVE GYM FLOOR) C107
GYM C101
09.210 03.355 03.355
07.950
09.210
BLDG B
07.950 04.220 STAGE LEVEL 3' - 0"
STAGE LEVEL 3' - 0"
STAGE LEVEL 3' - 0"
BLDG C
NORTH
07.950
FLOOR PLAN 0"
FLOOR PLAN 0"
FLOOR PLAN 0"
FLOOR PLAN 0"
FLOOR PLAN 0"
KEY PLAN
E
IA
*
DA V
RN
SS
AU
FLS
N
AT
AC
ID
No. C-20662 Exp. 3-31-19
ST
04-116805
A SED RCH I EN RUH
* CT TE
IDENTIFICATION STAMP DIV OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES
L IC
DSA File No:
OF
CA L I
FO
DATE STAMPS
BRANDING
ALVIN DUNN K-8 SCHOOL SCALE:
WALL SECTION - E RRC PROJECT No. : 1-84-28E 12/12/2017 7:19:01 PM DRAWN BY:
CHECKED BY:
SCALE:
1/2" = 1'-0" REF.:
1 /A1_5.2
5
WALL SECTION - D
SCALE:
1/2" = 1'-0" REF.:
1 /A1_5.2
4
WALL SECTION - C
SCALE:
1/2" = 1'-0" REF.:
1 /A1_5.2
3
WALL SECTION - B
SCALE:
1/2" = 1'-0" REF.:
1 /A1_5.2
2
WALL SECTION - A
1/2" = 1'-0" REF.:
2 /A1_5.2
1
3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
RRCARCH.COM
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
(951) 684 4664 /
5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010 (760) 438 5899
WALL SECTIONS
A1_6.1 1-84-28E
GENERAL NOTES
G
E
1.
SLAB ON GRADE: 0'-0" = GLOBAL ELEVATION: 78.42'
2.
VERIFY ALL EXTERIOR ROOF OPENINGS & VENTS WITH MECHANICAL, ELECTRICAL, STRUCTURAL & PLUMBING DRAWINGS. SEE DETAILS 8, 17 & 18/AD3.1 FOR TYPICAL ROOF VENT PENETRATION DETAIL.
3.
PROVIDE R-38 RIGID INSULATION OVER (STRUCTUE TYPE). SEE DETAIL 4/AD3.1 FOR TYPICAL ROOF CONSTRUCTION ASSEMBLY.
4.
PROVIDE R-19 BATT INSULATION AT ALL EXTERIOR WALLS, U.N.O. GYPSUM BOARD AND INSULATION SHALL EXTEND FULL HEIGHT OF WALL TO UNDERSIDE OF ROOF STRUCTURE
5.
ALL EXPOSED STRUCTURE, INCLUDING MECHANICAL & PLUMBING EQUIPMENT TO BE PAINTED
8
1 AD3.1
T.O. GYM PARAPET 29' - 4"
T.O. GYM PARAPET 29' - 4"
03.355 04.220 05.301 05.705 07.511
1 AD3.1 1 05.301
05.705
07.511
AD3.1
10 AD3.1
T.O. STAGE PARAPET 26' - 8"
T.O. STAGE PARAPET 26' - 8"
KEYNOTES
T.O. GYM PARAPET 29' - 4"
07.511
CONCRETE SLAB ON GRADE, PER STRUCTURAL DRAWINGS CONCRETE UNIT MASONRY, PER PLAN METAL ROOF DECK, PER STRUCTURAL DRAWINGS SINGLE PLY ROOF MEMBRANE OVER 7" OF RIGID INSULATION, SEE DETAIL 4/AD3.1 FOR ROOF ASSEMBLY EXPANSION CONTROL JOINT, PER DETAIL 12/S0.5 ACOUSTICAL CEILING SUSPENSION ASSEMBLY ILLUMINATED EXIT SIGN
07.950 09.530 26.530
05.301
10 AD3.1
10 AD3.1 07.511
24' - 4" T.O. STEEL
05.301
K
04.220
1 AD3.1
04.220
T. O. PARAPET 19' - 4" 04.220 9 T.O. LOWER PARAPET 18' - 0"
AD3.1
10 16' - 4" T.O. STEEL
AD3.1
20 AD3.1
10 AD3.1
26.530
9 AD3.1
14' - 6" T.O. STEEL
11' - 4"
15 AD5.1 09.530 T.O. WALL 8' - 8" BOYS BATHROOM C124
BLDG A MPR STAGE (ELEVATED 36" ABOVE GYM FLOOR) C107
GYM C101
LOBBY C103
LOBBY C103
BLDG B
10' - 0"
CORRIDOR C115
LOBBY C103
07.950 STAGE LEVEL 3' - 0"
BLDG C
07.950 07.950 03.355
07.950 NORTH
07.950
FLOOR PLAN 0"
FLOOR PLAN 0"
FLOOR PLAN 0"
FLOOR PLAN 0"
FLOOR PLAN 0"
KEY PLAN
E
IA
*
DA V
RN
SS
AU
FLS
N
AT
AC
ID
No. C-20662 Exp. 3-31-19
ST
04-116805
A SED RCH I EN RUH
* CT TE
IDENTIFICATION STAMP DIV OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES
L IC
DSA File No:
OF
CA L I
FO
DATE STAMPS
BRANDING
ALVIN DUNN K-8 SCHOOL SCALE:
WALL SECTION - K RRC PROJECT No. : 1-84-28E 12/12/2017 7:19:03 PM DRAWN BY:
CHECKED BY:
SCALE:
1/2" = 1'-0" REF.:
1 /A1_5.1
6
WALL SECTION - J
SCALE:
1/2" = 1'-0" REF.:
1 /A1_5.1
5
WALL SECTION - H
SCALE:
1/2" = 1'-0" REF.:
1 /A1_5.1
4
WALL SECTION - G
SCALE:
1/2" = 1'-0" REF.:
3 /A1_5.1
2
WALL SECTION - F
1/2" = 1'-0" REF.:
3 /A1_5.1
1
3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
RRCARCH.COM
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
(951) 684 4664 /
5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010 (760) 438 5899
WALL SECTIONS
A1_6.2 1-84-28E
GENERAL NOTES
G
C
B
C
B
1.
SLAB ON GRADE: 0'-0" = GLOBAL ELEVATION: 78.42'
2.
VERIFY ALL EXTERIOR ROOF OPENINGS & VENTS WITH MECHANICAL, ELECTRICAL, STRUCTURAL & PLUMBING DRAWINGS. SEE DETAILS 8, 17 & 18/AD3.1 FOR TYPICAL ROOF VENT PENETRATION DETAIL.
3.
PROVIDE R-38 RIGID INSULATION OVER (STRUCTUE TYPE). SEE DETAIL 4/AD3.1 FOR TYPICAL ROOF CONSTRUCTION ASSEMBLY.
4.
PROVIDE R-19 BATT INSULATION AT ALL EXTERIOR WALLS, U.N.O. GYPSUM BOARD AND INSULATION SHALL EXTEND FULL HEIGHT OF WALL TO UNDERSIDE OF ROOF STRUCTURE
5.
ALL EXPOSED STRUCTURE, INCLUDING MECHANICAL & PLUMBING EQUIPMENT TO BE PAINTED
A
2' - 0"
1 1
AD3.1 05.301
AD3.1
07.511
T.O. GYM PARAPET 29' - 4"
KEYNOTES
T.O. GYM PARAPET 29' - 4" 04.220 05.301 05.401 07.511
07.511 05.301
07.511
CONCRETE UNIT MASONRY, PER PLAN METAL ROOF DECK, PER STRUCTURAL DRAWINGS METAL STUD FRAMING SINGLE PLY ROOF MEMBRANE OVER 7" OF RIGID INSULATION, SEE DETAIL 4/AD3.1 FOR ROOF ASSEMBLY EXPANSION CONTROL JOINT, PER DETAIL 12/S0.5 ACOUSTICAL CEILING SUSPENSION ASSEMBLY LETTER MARQUEE ILLUMINATED EXIT SIGN
07.950 09.530 10.734 26.530
10 AD3.1
05.301
24' - 8" T.O. STEEL
24' - 8" T.O. STEEL
07.511
05.301 05.301
07.511 1 AD3.1
04.220 T.O. PARAPET 21' - 4"
T.O. PARAPET 21' - 4"
20' - 0" T.O. STEEL
20' - 0" T.O. STEEL 1 AD3.1
9 AD3.1
04.220
04.220 10.734
13' - 0" T.O. STEEL
26.530 09.530
09.530 09.530
BLDG A GYM C101
GYM C101
VESTIBULE C100
LOBBY C103
VESTIBULE C100
BLDG B
05.401
07.950
BLDG C
07.950
NORTH
07.950
FLOOR PLAN 0"
FLOOR PLAN 0"
KEY PLAN
E
IA
RN
SS
AU
FLS
N
AT
AC
ID
No. C-20662 Exp. 3-31-19
ST
04-116805
A SED RCH I EN RUH
* CT TE
IDENTIFICATION STAMP DIV OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES
AD5.1
L IC
DSA File No:
15
DA V
FLOOR PLAN 0"
*
FLOOR PLAN 0"
OF
CA L I
FO
DATE STAMPS
BRANDING
ALVIN DUNN K-8 SCHOOL SCALE:
WALL SECTION - PP RRC PROJECT No. : 1-84-28E 12/12/2017 7:19:05 PM DRAWN BY:
CHECKED BY:
SCALE:
1/2" = 1'-0" REF.:
4 /A1_5.1
4
WALL SECTION - N
SCALE:
1/2" = 1'-0" REF.:
4 /A1_5.1
3
WALL SECTION - M
SCALE:
1/2" = 1'-0" REF.:
4 /A1_5.1
2
WALL SECTION - L
1/2" = 1'-0" REF.:
2 /A1_5.1
1
3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
RRCARCH.COM
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
(951) 684 4664 /
5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010 (760) 438 5899
WALL SECTIONS
A1_6.3 1-84-28E
GENERAL NOTES
A
1.
SLAB ON GRADE: 0'-0" = GLOBAL ELEVATION: 78.42'
2.
VERIFY ALL EXTERIOR ROOF OPENINGS & VENTS WITH MECHANICAL, ELECTRICAL, STRUCTURAL & PLUMBING DRAWINGS. SEE DETAILS 8, 17 & 18/AD3.1 FOR TYPICAL ROOF VENT PENETRATION DETAIL.
3.
PROVIDE R-38 RIGID INSULATION OVER (STRUCTUE TYPE). SEE DETAIL 4/AD3.1 FOR TYPICAL ROOF CONSTRUCTION ASSEMBLY.
4.
PROVIDE R-19 BATT INSULATION AT ALL EXTERIOR WALLS, U.N.O. GYPSUM BOARD AND INSULATION SHALL EXTEND FULL HEIGHT OF WALL TO UNDERSIDE OF ROOF STRUCTURE
5.
ALL EXPOSED STRUCTURE, INCLUDING MECHANICAL & PLUMBING EQUIPMENT TO BE PAINTED
J
KEYNOTES 04.220 05.301 05.401 07.511
CONCRETE UNIT MASONRY, PER PLAN METAL ROOF DECK, PER STRUCTURAL DRAWINGS METAL STUD FRAMING SINGLE PLY ROOF MEMBRANE OVER 7" OF RIGID INSULATION, SEE DETAIL 4/AD3.1 FOR ROOF ASSEMBLY EXPANSION CONTROL JOINT, PER DETAIL 12/S0.5 5/8" GYPSUM BOARD PER WALL TYPE, WALL FINISH PER FINISH SCHEDULE, SEE SHEET A1_9.1 ACOUSTICAL CEILING SUSPENSION ASSEMBLY LETTER MARQUEE
07.950 09.210 09.530 10.734
1 AD3.1
10.734 10
T.O. KITCHEN PARAPET 16' - 8"
AD3.1 20 AD3.1 14' - 10" T.O. STEEL
13' - 2" T.O. STEEL
22 AD5.1
BLDG A MEN C104
KITCHEN C133 04.220 09.210
BLDG B
05.401
BLDG C 07.950 NORTH
07.950
FLOOR PLAN 0"
FLOOR PLAN 0"
KEY PLAN
E
IA
*
DA V
RN
SS
AU
FLS
N
AT
AC
ID
No. C-20662 Exp. 3-31-19
ST
04-116805
A SED RCH I EN RUH
* CT TE
IDENTIFICATION STAMP DIV OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES
L IC
DSA File No:
OF
CA L I
FO
DATE STAMPS
BRANDING
ALVIN DUNN K-8 SCHOOL SCALE:
WALL SECTION - R RRC PROJECT No. : 1-84-28E 12/12/2017 7:19:05 PM DRAWN BY:
CHECKED BY:
SCALE:
1/2" = 1'-0" REF.:
/
2
WALL SECTION - Q
1/2" = 1'-0" REF.:
4 /A1_5.1
1
3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
RRCARCH.COM
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
(951) 684 4664 /
5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010 (760) 438 5899
WALL SECTIONS
A1_6.4 1-84-28E
GENERAL NOTES G
G
G
2
3
3
2
A1_7.1
A1_7.1
A1_7.1
A1_7.1
07.511
05.301
07.511
2.
ALL DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF COLUMN OR EDGE OF SLAB, U.N.O.
3.
PROVIDE STUD BRACING AND SUPPORT FOR ALL WALL MOUNTED FIXTURES AND ACCESSORIES. PER DETAIL 20/S0.9
4.
PROVIDE GROMMETS AND RINGS IN COUNTER TOPS 60"O.C. FOR POWER AND DATA
07.511
T.O. STAGE PARAPET 26' - 8"
T.O. STAGE PARAPET 26' - 8"
KEYNOTES
04.220
23' - 6" T.O. STEEL
23' - 4" T.O. STEEL
22.145
VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION.
05.301 05.301
T.O. STAGE PARAPET 26' - 8"
1.
03.355 04.220 05.301 07.511
CONCRETE SLAB ON GRADE, PER STRUCTURAL DRAWINGS CONCRETE UNIT MASONRY, PER PLAN METAL ROOF DECK, PER STRUCTURAL DRAWINGS SINGLE PLY ROOF MEMBRANE OVER 7" OF RIGID INSULATION, SEE DETAIL 4/AD3.1 FOR ROOF ASSEMBLY HOLLOW METAL DOOR AND FRAME, PER DOOR SCHEDULE ON SHEET A1_8.1 5/8" GYPSUM BOARD PER WALL TYPE, WALL FINISH PER FINISH SCHEDULE, SEE SHEET A1_9.1 ACOUSTICAL CEILING SUSPENSION ASSEMBLY ROOF DRAIN, PER DETAILS 13 & 16/AD3.1
08.121 09.210 09.530 22.145
04.220
04.220
09.530 VESTIBULE C108
12"
FLOOR PLAN 0"
FLOOR PLAN 0"
EQ
2' - 10"
2' - 10"
2' - 10"
2' - 10"
6 R @ 6"
EQ
6"
2' - 10"
6"
3' - 0"
6"
8' - 0"
EQ
T + 12"
STAGE LEVEL 3' - 0" 3' - 0"
LEVEL EQ
8' - 0"
2' - 10"
03.355
CORRIDOR C115
12"
LEVEL 6"
STAGE ACCESS C109
T + 12"
03.355 03.355 STAGE LEVEL 3' - 0"
STAGE LEVEL 3' - 0"
FLOOR PLAN 0"
FLOOR PLAN 0"
2' - 10"
VESTIBULE C108
6 R @ 6"
08.121
09.530
MPR STAGE (ELEVATED 36" ABOVE GYM FLOOR) C107
FLOOR PLAN 0"
FLOOR PLAN 0"
4' - 7" 5 EQ. THREADS
SCALE:
Section 1
SCALE:
1/4" = 1'-0" REF.:
1 /A1_7.1
6
Stairs
13 6
5 A1_7.1
5 A1_7.1
REF.:
1 /A1_7.1
5
Section 7
8
13 A1_7.1
SCALE:
1/4" = 1'-0"
1/4" = 1'-0" REF.:
1 /A1_7.1
4
13
6
4
5
6
A1_7.1
A1_7.1
A1_7.1
A1_7.1
2
Sim
AD2.1
BLDG A T.O. STAGE PARAPET 26' - 8"
05.301
07.511
5 A1_7.1
10' - 2 1/8"
Sim 5
04.220
MPR STAGE (ELEVATED 36" ABOVE GYM FLOOR)
M.O.
23' - 4" T.O. STEEL
2
A1_7.1
AD2.1
07.511
T.O. BAND PARAPET 20' - 8"
Sim
BLDG B
05.301
05.301
3' - 3 5/8" Sim
07.511
07.511
7' - 2"
T.O. STAGE PARAPET 26' - 8"
4' - 0"
T.O. STAGE PARAPET 26' - 8"
18' - 8" T.O. STEEL
3' - 0" 1' - 8 63/256"
3' - 0"
BLDG C
NORTH
2
VESTIBULE
STAGE ACCESS
1' - 4"
20' - 3"
03.355 STAGE LEVEL 3' - 0"
STAGE LEVEL 3' - 0"
FLOOR PLAN 0"
FLOOR PLAN 0"
FLOOR PLAN 0"
5' - 0"
N
SS
E
OF
IA
RN
No. C-20662 Exp. 3-31-19
CA L I
FO
DATE STAMPS
5' - 0" 0"
M.O.
CORRIDOR
FLS
ID
AT
G
0"
L IC
04-116805 AC
03.355
DA V
A1_7.1
*
48" MIN. CLR.
DN
5' - 0"
M.O.
4' - 0"
1:12 MAX SLOPE
3
ST
VESTIBULE C108
UP
A SED RCH I EN RUH
AU
VESTIBULE C108
IDENTIFICATION STAMP DIV OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES
* CT TE
STAGE ACCESS C109
KEY PLAN DSA File No:
2% MAX. SLOPE
09.530
A1_7.1
13' - 4"
48" MIN. CLR.
1:12 MAX SLOPE
3' - 8"
DN
09.530
2% MAX. SLOPE
10' - 8"
6' - 0"
6' - 8"
18' - 8" T.O. STEEL
4' - 0"
05.301
8
13
BRANDING
ALVIN DUNN K-8 SCHOOL SCALE:
Section 9 RRC PROJECT No. : 1-84-28E 12/11/2017 4:49:12 PM DRAWN BY:
CHECKED BY:
SCALE:
1/4" = 1'-0" REF.:
5 /A1_6.2
3
Section 8
SCALE:
1/4" = 1'-0" REF.:
1 /A1_7.1
2
STAGE STAIRS & RAMP
1/4" = 1'-0" REF.:
1 /A1_1.1
1
3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
RRCARCH.COM
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
(951) 684 4664 /
5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010 (760) 438 5899
ENLARGED STAIRS & RAMPS
A1_7.1 1-84-28E
8
15
07.511
GENERAL NOTES
15 2
3
2
3
A1_7.2
A1_7.2
A1_7.2
A1_7.2
05.301
07.511
05.301
1.
VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION.
2.
ALL DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF COLUMN OR EDGE OF SLAB, U.N.O.
3.
PROVIDE STUD BRACING AND SUPPORT FOR ALL WALL MOUNTED FIXTURES AND ACCESSORIES. PER DETAIL 20/S0.9
4.
PROVIDE GROMMETS AND RINGS IN COUNTER TOPS 60"O.C. FOR POWER AND DATA
22.145
T.O. BAND PARAPET 20' - 8"
T.O. BAND PARAPET 20' - 8"
LOBBY C103 04.220 TYP 04.220
GYM
KEYNOTES
4' - 7" 3' - 0"
09.530
09.530
03.355 04.220 05.301 05.401 07.511
E
0"
4' - 0"
6 A1_7.1 DN Sim 5
CONCRETE SLAB ON GRADE, PER STRUCTURAL DRAWINGS CONCRETE UNIT MASONRY, PER PLAN METAL ROOF DECK, PER STRUCTURAL DRAWINGS METAL STUD FRAMING SINGLE PLY ROOF MEMBRANE OVER 7" OF RIGID INSULATION, SEE DETAIL 4/AD3.1 FOR ROOF ASSEMBLY 5/8" GYPSUM BOARD PER WALL TYPE, WALL FINISH PER FINISH SCHEDULE, SEE SHEET A1_9.1 ACOUSTICAL CEILING SUSPENSION ASSEMBLY ROOF DRAIN, PER DETAILS 13 & 16/AD3.1
09.210 09.530 22.145
A1_7.1
03.355
MPR STAGE (ELEVATED 36" ABOVE GYM FLOOR) C107
FLOOR PLAN 0"
SCALE:
FLOOR PLAN - STAGE STAIRS
STAGE LEVEL 3' - 0"
FLOOR PLAN 0"
FLOOR PLAN 0"
SCALE:
6
1/4" = 1'-0" REF.:
STAGE LEVEL 3' - 0" 1' - 6"
1' - 6"
STAGE LEVEL 3' - 0"
2' - 10"
2' - 10"
7' - 2"
1 /A1_1.1
Section 3
SCALE:
1/4" = 1'-0" 1 /A1_7.2
REF.:
5
EXTERIOR RAMP PLATFORM 15
5
A1_7.2
A1_7.2
2
3
A1_7.2
A1_7.2
1 /A1_7.2
REF.:
4
4' - 7"
4
1/4" = 1'-0"
3' - 0"
TYP.
20 AD2.1
3 AD2.1
TYP.
4
8' - 6"
7' - 3"
A1_7.2
1 1/2" O.D. PAINTED PIPEHANDRAIL; COLOR TO BE SELECTED BY ARCHITECT
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
FIN. GRADE OR SLAB; SEE PLANS T + 12" 12"
LEVEL
2' - 10"
2' - 10"
STAGE LEVEL 3' - 0"
8' - 6"
1' - 6"
4' - 7"
17' - 3"
5' - 0"
17' - 3"
FLOOR PLAN 0" 3' - 0"
FLOOR PLAN 0"
18' - 0"
BLDG A
5' - 0" MAX.TYP.
SCALE:
Section 4
1/4" = 1'-0" 1 /A1_7.2
REF.:
3 1' - 6"
4
A1_7.2
A1_7.2 4' - 7"
5
BLDG C
A1_7.2
TYP. NORTH
15 AD2.1
5' - 0"
5
BLDG B
G
KEY PLAN DSA File No:
1' - 0" 4' - 0"
4' - 0"
6"
3' - 3"
6"
5' - 0"
5' - 0"
5' - 0"
6"
EQ
1' - 6"
RN
SS
E
OF
IA
L IC
DA V
No. C-20662 Exp. 3-31-19
CA L I
FO
DATE STAMPS
FIN. GRADE OR SLAB; SEE PLANS
STAGE LEVEL 3' - 0"
0" FLOOR PLAN 0"
3' - 0"
FLOOR PLAN 0"
FLS
EQ
2' - 10"
5' - 0"
2' - 10"
5' - 0"
1' - 0"
2' - 10"
5' - 0"
2' - 10"
6"
2' - 10"
TYP.
2' - 10"
15 AD2.1
5' - 6"
AC
N
AT
AD2.1
*
04-116805
Sim
ST
2
18' - 0"
8"
ID
AU
2' - 0"
A SED RCH I EN RUH
* CT TE
IDENTIFICATION STAMP DIV OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES
G
G BRANDING
1' - 0"
18' - 0"
5' - 0"
17' - 3"
8' - 6"
4' - 7"
ALVIN DUNN K-8 SCHOOL SCALE:
EXTERIOR RAMP - A RRC PROJECT No. : 1-84-28E 12/11/2017 4:49:18 PM DRAWN BY:
CHECKED BY:
SCALE:
1/4" = 1'-0" REF.:
1 /A1_7.2
2
EXTERIOR RAMP
1/4" = 1'-0" REF.:
1 /A1_1.1
1
3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
RRCARCH.COM
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
(951) 684 4664 /
5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010 (760) 438 5899
ENLARGED STAIRS & RAMPS
A1_7.2 1-84-28E
KEYNOTES 10.290
1 / NORTH
2 / EAST
08.121 09.210 10.282 10.283 10.284 10.286 10.287 10.290 10.292 10.295 10.441
08.121
3 / SOUTH
4 / WEST
2' - 0"
CL 10.292 10.292
10.290 10.283
22.404 10.286
7" - 9"
10.282
OPERABLE PARTS
22.401
10.287 MAX. 40" TO
10.283
MAX 3' - 4" A.F.F.
33" - 36"
10.286
OF LAVATORY
2' - 10" @ TOP
10.282
TO BOTTOM OF MIRROR
10.282
MIN
1' - 7"
2' - 6"
6"
10.290
22.404
22.401
HOLLOW METAL DOOR AND FRAME, PER DOOR SCHEDULE ON SHEET A1_8.1 5/8" GYPSUM BOARD PER WALL TYPE, WALL FINISH PER FINISH SCHEDULE, SEE SHEET A1_9.1 GRAB BAR TOILET PAPER DISPENSER 2-STALL TOILET TISSUE DISPENSER / NAPKIN DISPOSAL, REFER TO SPECIFICATIONS TOILET SEAT COVER DISPENSER SOAP DISPENSER ELECTRIC HAND DRYER GLASS MIRROR SINGLE STALL TOILET TISSUE DISPENSER / NAPKIN DISPOSAL, REFER TO SPECIFICATIONS SEMI-RECESSED FIRE EXTINGUISHER CABINET, SEE SHEETS AS-0.2 FOR ALL LOCATIONS, PER DETAIL 1/AD7.1 LOCKER ROOM BENCH LOCKERS WATER CLOSET URINAL, REFER TO SPECIFICATIONS LAVATORY SINK AND FAUCET, PER PLUMBING DRAWINGS 42" FLAT SCREEN TELEVSION, MOUNTED TO WALL; PROVIDE POWER AND DATA
10.514 11.651 22.401 22.402 22.404 22.405 27.420
TOILET ACCESSORIES SCHEDULE KEYNOTE #
SURFACE MOUNTED SOAP DISPENSER (OFCI) B-2111 MIRROR W/ SS CHANNEL FRAME & SHELF B-165 1836
10.287 SCALE:
TOILET 290 - COACH'S RESTROOM
4
1/4" = 1'-0"
10.292
RECESSED - SINGLE STALLTOILET SEAT COVER & TISSUE DISPENSERS, NAPKIN DISPOSAL (OFCI) B-3574 (WOMEN) B-3474 (BOYS & MEN)
10.295
08.121
08.121
10.282
08.121
1 / NORTH
2 / EAST
10.287
10.290
10.441
3 / SOUTH
4 / WEST
7" - 9" MAX
22.401
10.284
10.295
22.402
OPERABLE PARTS
MAX. 40" TO
OF LAVATORY
2' - 10" @ TOP
33" - 36"
1' - 4"
1' - 6"
10.283
1' - 4"
22.405
REFER TO DETAIL ON AD9.1 REFER TO DETAIL ON AD9.1
REFER TO DETAIL ON AD9.1
10.286
SURFACE MOUNTED - TOILET SEAT COVER DISPENSER B-221 (OFCI)
REFER TO DETAIL ON AD9.1
10.283
RECESSED MULTI-ROLL TOILET TISSUE DISPENSER B-3888 (OFCI)
REFER TO DETAIL ON AD9.1
10.282
GRAB BAR - B-6806 36" (BACK), 46" (SIDE) MIN. LONG
REFER TO DETAIL ON AD9.1
10.290
ELECTRIC HAND DRYER (RECESSED) PINNACLE #PDC - R10
REFER TO DETAIL ON AD9.1
10.283
RECESSED MULTI-ROLL TOILET TISSUE DISPENSER - B-3888 (OFCI)
REFER TO DETAIL ON AD9.1
10.285
RECESSED SANITARY NAPKIN DISPOSAL B-4353 (OFCI)
REFER TO DETAIL ON AD9.1
10.284
RECESSED - DOUBLE STALLTOILET SEAT COVER & TISSUE DISPENSERS, NAPKIN DISPOSAL (OFCI) B-3571 (WOMEN) B-3471 (BOYS & MEN)
10.284 10.287
MOUNTING REQUIREMENTS SEE DETAIL REFERENCE
UNIT NAME
REFER TO DETAIL ON AD9.1
22.405
ACCESSORIES NOTES: 1. INSTALL ACCESSORIES BACK TO BACK WHERE SHOWN. SCALE:
TOILET 275 - @ BOYS LOCKER ROOM
3
1/4" = 1'-0"
2. WHERE ACCESSORIES ARE NOT BACK TO BACK, ANCHOR ACCESSORIES TO PARTITIONS WITH STAINLESS STEEL DISK PLATES (SIZE AS REQUIRED) MOUNTED ON PARTITION OPPOSITE TO ACCESSORY SO AS TO ALLOW THROUGH BOLTING. (EXPOSED FASTENERS TO BE CARRIAGE BOLT HEADS ONLY. 3. LIMIT THE PROJECTION OF A SURFACE OR SEMI-SURFACE MOUNTED ACCESSORY ITEM FROM ENCROACHING MORE THAN 3" FROM THE FACE OF THE WALL OR PARTITION, AND NO CLOSER THAN 1 1/2" TO THE TANGENT POINT OF THE GRAB BAR. 4. GRAB BAR LENGTHS ARE: FOR SIDE WALL 42" MIN. AND FOR BACK WALL 36" MIN.
4
12
A1_7.1
08.121
ABBREVIATIONS: TOP TOP OF OPERABLE PART FOF FACE OF FINISH FOP FACE OF PARTITION BF BARRIER FREE
11.651
11.651
GENERAL SHEET NOTES
1 / NORTH
2 / EAST
1. KEYNOTE # INDICATES TOILET ROOM ACCESSORIES, SEE SCHEDULE ABOVE 2. PROVIDE U-SHAPED OR WIRE DOOR PULLS BOTH SIDE OF ACCESSIBLE COMPARTMENT DOORS.
H
4. FOR TOILET FIXTURES AND ACCESSORIES MOUNTING HEIGHT SEE SHEET AD9.2 CLR
CLR
3. REFER TO TOILET ROOM ACCESSORIES LIST. LIMIT THE PROJECTION OF A SURFACE OR SEMISURFACE MOUNTED ACCESSORY ITEM FROM ENCROACHING MORE THAN 3" FROM THE FACE OF THE WALL OR PARTITION, AND NO CLOSER THAN 1 1/2" TO THE TANGENT POINT OF THE GRAB BAR. 48 MIN
10.441
5' - 0" MIN
H
5. VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. 6. ALL DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF COLUMN OR EDGE OF SLAB, U.N.O.
36" MIN
CLR
CLR
10.290 9' - 3 7/8"
5' - 0" MIN 7' - 6"
30"x48"
CLR
6' - 4 3/4"
5' - 0" MIN
7.PROVIDE STUD BRACING AND SUPPORT FOR ALL WALL MOUNTED FIXTURES AND ACCESSORIES. PER DETAIL 20/S0.9 8. PROVIDE GROMMETS AND RINGS IN COUNTER TOPS 60"O.C. FOR POWER AND DATA
11.651
NOTE: ALL DIMENSIONS ARE TO FACE OF FINISHED FLOOR AND WALL FINISH, UNLESS OTHERWISE NOTED.
10.441 10.514
16' - 2 1/2"
BOYS LOCKER ROOM 1 C119 4 2 2 / A1_7.3 3
11.651 30' - 4"
7' - 0"
2
CLR
11.651
2' - 6"
1' - 6"
2' - 6"
D
NORTH
L IC
DA V
04-116805
12" MAX
CLR
5' - 0" MIN
MAX CL
CL
1' - 6" MAX
AC
FLS
A SED RCH I EN RUH ID
N
No. C-20662 Exp. 3-31-19
AT
1' - 6"
2' - 0"
IDENTIFICATION STAMP DIV OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES
ST
3' - 6"
CL
DSA File No:
AU
24" MIN
2
SS
* CT TE
12" MAX
4
KEY PLAN
8' - 8"
CLR
COACH'S OFFICE C122
4' - 0" MIN CLR/. TYP.
10.441
TOILET 1 C121 9 / A1_7.3 3
J
*
6' - 0"
34" MIN
6' - 8" A.F.F.
BLDG C
CLR
3' - 0"
CL
J
8' - 0" 6' - 8 1/2"
4 / WEST
34" MIN CLR
3 / SOUTH
32" DOOR
AD1.2
12" MIN
11.651
3
3' - 0"
08.121
3' - 8 1/2"
08.121
MIN
08.121
1' - 2"1' - 10"
27.420
27.420
E
OF
IA
3' - 0"
RN
2' - 6"
BLDG B
1' - 6"
W
3' - 0"
CLR
3' - 0"
EQ
34" MIN CLR
2' - 6"
4' - 11"
11.651
BLDG A
30"x48"
CL
EQ
4
10.514
3' - 10"
72" MIN
BOYS BATHROOM 1 C124 3 / A1_7.3 3
CA L I
FO
DATE
K
5' - 1 3/4" 60" MIN CLR
L
STAMPS
L
10.286 10' - 4 1/8"
6' - 0"
11
24' - 0 3/4"
12 BRANDING
ALVIN DUNN K-8 SCHOOL SCALE:
ROOM 234 - BOYS LOCKER ROOM RRC PROJECT No. : 1-84-28E 12/11/2017 4:49:28 PM DRAWN BY:
CHECKED BY:
1/4" = 1'-0"
SCALE:
2
BOYS LOCKER ROOMS
1/4" = 1'-0"
1
3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
RRCARCH.COM
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
(951) 684 4664 /
5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010 (760) 438 5899
ENLARGED PLANS / INTERIOR ELEVATIONS
A1_7.3 1-84-28E
KEYNOTES 08.121
04.220 08.121 09.210 10.282 10.283 10.284 10.285 10.286 10.287 10.290 10.292 10.295 10.441
10.282
1 / NORTH
2 / EAST
4 / WEST
3 / SOUTH 2' - 0"
CL 10.292 10.287 10.283
10.514 11.651 22.401 22.404 22.405 22.471 27.420
6" 10.285
22.404
2' - 6"
10.285
1' - 7"
10.283
3"
33" - 36"
10.282
MIN
OF LAVATORY
2' - 10" @ TOP
22.404
TO BOTTOM OF MIRROR
MAX 3' - 4" A.F.F.
10.286
10.290 10.287
OPERABLE PARTS
MAX 40" TO
10.290
1' - 4"
10.292
4"
22.401
TOILET ACCESSORIES SCHEDULE
7" - 9" 10.286
22.401
CONCRETE UNIT MASONRY, PER PLAN HOLLOW METAL DOOR AND FRAME, PER DOOR SCHEDULE ON SHEET A1_8.1 5/8" GYPSUM BOARD PER WALL TYPE, WALL FINISH PER FINISH SCHEDULE, SEE SHEET A1_9.1 GRAB BAR TOILET PAPER DISPENSER 2-STALL TOILET TISSUE DISPENSER / NAPKIN DISPOSAL, REFER TO SPECIFICATIONS SANITARY NAPKIN DISPOSAL TOILET SEAT COVER DISPENSER SOAP DISPENSER ELECTRIC HAND DRYER GLASS MIRROR SINGLE STALL TOILET TISSUE DISPENSER / NAPKIN DISPOSAL, REFER TO SPECIFICATIONS SEMI-RECESSED FIRE EXTINGUISHER CABINET, SEE SHEETS AS-0.2 FOR ALL LOCATIONS, PER DETAIL 1/AD7.1 LOCKER ROOM BENCH LOCKERS WATER CLOSET LAVATORY SINK AND FAUCET, PER PLUMBING DRAWINGS DRINKING FOUNTAIN 42" FLAT SCREEN TELEVSION, MOUNTED TO WALL; PROVIDE POWER AND DATA
KEYNOTE #
SURFACE MOUNTED SOAP DISPENSER (OFCI) B-2111 MIRROR W/ SS CHANNEL FRAME & SHELF B-165 1836
10.287 SCALE:
TOILET 246 - COACH'S RESTROOM
1/4" = 1'-0" REF.:
/
4
10.292
RECESSED - SINGLE STALLTOILET SEAT COVER & TISSUE DISPENSERS, NAPKIN DISPOSAL (OFCI) B-3574 (WOMEN) B-3474 (BOYS & MEN)
10.295
08.121 10.441
10.290
2 / EAST
3 / SOUTH
4 / WEST
10.284
22.405
10.285
10.284
10.285
10.295
33" -36"
1' - 4"
3' - 2"
OF LAVATORY
22.405
10.283 2' -10" @ TOP
MAX. 40" TO
10.287
OPERABLE PARTS
10.282
22.405
REFER TO DETAIL ON AD9.1 REFER TO DETAIL ON AD9.1 REFER TO DETAIL ON AD9.1
10.286
SURFACE MOUNTED - TOILET SEAT COVER DISPENSER B-221 (OFCI)
REFER TO DETAIL ON AD9.1
10.283
RECESSED MULTI-ROLL TOILET TISSUE DISPENSER B-3888 (OFCI)
REFER TO DETAIL ON AD9.1
10.282
GRAB BAR - B-6806 36" (BACK), 46" (SIDE) MIN. LONG
REFER TO DETAIL ON AD9.1
10.290
ELECTRIC HAND DRYER (RECESSED) PINNACLE #PDC - R10
REFER TO DETAIL ON AD9.1
10.283
RECESSED MULTI-ROLL TOILET TISSUE DISPENSER - B-3888 (OFCI)
REFER TO DETAIL ON AD9.1
10.285
RECESSED SANITARY NAPKIN DISPOSAL B-4353 (OFCI)
REFER TO DETAIL ON AD9.1
10.284
RECESSED - DOUBLE STALLTOILET SEAT COVER & TISSUE DISPENSERS, NAPKIN DISPOSAL (OFCI) B-3571 (WOMEN) B-3471 (BOYS & MEN)
10.287
1 / NORTH
MOUNTING REQUIREMENTS SEE DETAIL REFERENCE
UNIT NAME
REFER TO DETAIL ON AD9.1
22.401
ACCESSORIES NOTES: 1. INSTALL ACCESSORIES BACK TO BACK WHERE SHOWN. SCALE:
TOILET 272 - @ GIRLS LOCKER ROOM
1/4" = 1'-0" REF.:
/
3
2. WHERE ACCESSORIES ARE NOT BACK TO BACK, ANCHOR ACCESSORIES TO PARTITIONS WITH STAINLESS STEEL DISK PLATES (SIZE AS REQUIRED) MOUNTED ON PARTITION OPPOSITE TO ACCESSORY SO AS TO ALLOW THROUGH BOLTING. (EXPOSED FASTENERS TO BE CARRIAGE BOLT HEADS ONLY. 3. LIMIT THE PROJECTION OF A SURFACE OR SEMI-SURFACE MOUNTED ACCESSORY ITEM FROM ENCROACHING MORE THAN 3" FROM THE FACE OF THE WALL OR PARTITION, AND NO CLOSER THAN 1 1/2" TO THE TANGENT POINT OF THE GRAB BAR.
6
4. GRAB BAR LENGTHS ARE: FOR SIDE WALL 42" MIN. AND FOR BACK WALL 36" MIN. ABBREVIATIONS: TOP TOP OF OPERABLE PART FOF FACE OF FINISH FOP FACE OF PARTITION BF BARRIER FREE
11.651
08.121
11.651
10.441
08.121
GENERAL SHEET NOTES
10.441
08.121
2 / EAST
1 / NORTH
1. KEYNOTE # INDICATES TOILET ROOM ACCESSORIES, SEE SCHEDULE ABOVE
H
H
2. PROVIDE U-SHAPED OR WIRE DOOR PULLS BOTH SIDE OF ACCESSIBLE COMPARTMENT DOORS.
1' - 6"
2' - 5"
1' - 6"
2' - 6"
3' - 0"
2' - 6"
1' - 6"
2' - 6"
3. REFER TO TOILET ROOM ACCESSORIES LIST. LIMIT THE PROJECTION OF A SURFACE OR SEMISURFACE MOUNTED ACCESSORY ITEM FROM ENCROACHING MORE THAN 3" FROM THE FACE OF THE WALL OR PARTITION, AND NO CLOSER THAN 1 1/2" TO THE TANGENT POINT OF THE GRAB BAR.
CLR
5' - 0" MIN
CLR
48" MIN
VESTIBULE
4. FOR TOILET FIXTURES AND ACCESSORIES MOUNTING HEIGHT SEE SHEET AD9.2 10.441
5. VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. 5' - 0" MIN
6. ALL DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF COLUMN OR EDGE OF SLAB, U.N.O.
5' - 0" MIN 7' - 6"
9' - 3 7/8"
CLR
NOTE: ALL DIMENSIONS ARE TO FACE OF FINISHED FLOOR AND WALL FINISH, UNLESS OTHERWISE NOTED.
CLR
72" MIN
41' - 0"
MIN CLR
CL
32" DOOR
SHOWER
3' - 0"
5' - 0"
BLDG B
27.420
2
BLDG A
6' - 0"
CLR
48" MIN
3' - 0"
10.514
4
7' - 0"
GIRLS LOCKER ROOM 1 C127 4 2 A1_7.4 3
11.651
GIRLS BATHROOM 1 C125 A1_7.4 3
3' - 10"
34" MIN CLR
10.514
11.651
8. PROVIDE GROMMETS AND RINGS IN COUNTER TOPS 60"O.C. FOR POWER AND DATA
30"x48"
10.441
11.651
7.PROVIDE STUD BRACING AND SUPPORT FOR ALL WALL MOUNTED FIXTURES AND ACCESSORIES. PER DETAIL 20/S0.9
10.290
1' - 2"1' - 10"
16' - 2 1/2"
6' - 4 3/4"
CLR
BLDG C
DSA File No:
12" MAX
K
AC
11.651
11.651
SS
E
OF
CA L I
IA
FO
STAMPS
L 22.471
10.514
No. C-20662 Exp. 3-31-19
DATE
L 10.514
FLS
*
04-116805
3' - 6"
N
AT
5' - 0" MIN
CL
ID
RN
24" MIN
A SED RCH I EN RUH
DA V
12" MAX
L IC
IDENTIFICATION STAMP DIV OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES
CLR
AU
CL
34" MIN
* CT TE
60 MIN CLR
10.441
CL
2' - 0"
KEY PLAN COACH'S OFFICE C129
1' - 2"
5' - 0 3/4"
34" MIN CLR
11
1 1/2" CLR
MAX
3' - 0"
6' - 6 1/2"
10
1' - 5"
TOILET 12 C130 A1_7.4 13
ST
6' - 8" A.F.F.
10' - 0"
4 / WEST
3' - 8 1/2"
3 / SOUTH
4' - 0" MIN CLR. TYP.
7' - 11"
NORTH
27.420
08.121
12" MIN
10.441
10.286 24' - 0"
6' - 0"
7
10' - 3 7/8"
9 BRANDING
ALVIN DUNN K-8 SCHOOL SCALE:
ROOM 314 - GIRLS' LOCKER ROOM RRC PROJECT No. : 1-84-28E 12/11/2017 4:49:39 PM DRAWN BY:
CHECKED BY:
SCALE:
1/4" = 1'-0" REF.:
/
2
GIRLS LOCKER ROOMS
1/4" = 1'-0" REF.:
1 /A1_1.1
1
3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
RRCARCH.COM
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
(951) 684 4664 /
5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010 (760) 438 5899
ENLARGED PLANS / INTERIOR ELEVATIONS
A1_7.4 1-84-28E
KEYNOTES 04.220 07.810 08.121 09.210 10.282 10.283 10.284 10.285 10.287 10.290 10.292 10.295 22.401 22.402 22.404 22.405 22.414 22.415
08.121
2 / EAST
1 / NORTH
4 / WEST
3 / SOUTH
3
TOILET ACCESSORIES SCHEDULE
22.415
22.415
CONCRETE UNIT MASONRY, PER PLAN APPLIED FIREPROOFING HOLLOW METAL DOOR AND FRAME, PER DOOR SCHEDULE ON SHEET A1_8.1 5/8" GYPSUM BOARD PER WALL TYPE, WALL FINISH PER FINISH SCHEDULE, SEE SHEET A1_9.1 GRAB BAR TOILET PAPER DISPENSER 2-STALL TOILET TISSUE DISPENSER / NAPKIN DISPOSAL, REFER TO SPECIFICATIONS SANITARY NAPKIN DISPOSAL SOAP DISPENSER ELECTRIC HAND DRYER GLASS MIRROR SINGLE STALL TOILET TISSUE DISPENSER / NAPKIN DISPOSAL, REFER TO SPECIFICATIONS WATER CLOSET URINAL, REFER TO SPECIFICATIONS LAVATORY SINK AND FAUCET, PER PLUMBING DRAWINGS MOP SINK, PER PLUMBING DRAWINGS MOP FAUCET, PER PLUMBING DRAWINGS
KEYNOTE #
SURFACE MOUNTED SOAP DISPENSER (OFCI) B-2111 MIRROR W/ SS CHANNEL FRAME & SHELF B-165 1836
10.287
22.414
22.414
9' - 7 1/4"
10.292
RECESSED - SINGLE STALLTOILET SEAT COVER & TISSUE DISPENSERS, NAPKIN DISPOSAL (OFCI) B-3574 (WOMEN) B-3474 (BOYS & MEN)
10.295
66
1' - 6" 10.292
5' - 0"
9' - 0"12" MAX
10.283
RECESSED MULTI-ROLL TOILET TISSUE DISPENSER B-3888 (OFCI)
REFER TO DETAIL ON AD9.1
10.282
GRAB BAR - B-6806 36" (BACK), 46" (SIDE) MIN. LONG
REFER TO DETAIL ON AD9.1
10.290
ELECTRIC HAND DRYER (RECESSED) PINNACLE #PDC - R10
REFER TO DETAIL ON AD9.1
10.283
RECESSED MULTI-ROLL TOILET TISSUE DISPENSER - B-3888 (OFCI)
REFER TO DETAIL ON AD9.1
10.285
RECESSED SANITARY NAPKIN DISPOSAL B-4353 (OFCI)
REFER TO DETAIL ON AD9.1
10.284
RECESSED - DOUBLE STALLTOILET SEAT COVER & TISSUE DISPENSERS, NAPKIN DISPOSAL (OFCI) B-3571 (WOMEN) B-3471 (BOYS & MEN)
REFER TO DETAIL ON AD9.1
TOP OF LAVATORY
22.401
22.401
3
2' - 8 1/2"
10.285
3"
10.283
1' - 4"
33" - 36"
10.282
6"
2. WHERE ACCESSORIES ARE NOT BACK TO BACK, ANCHOR ACCESSORIES TO PARTITIONS WITH STAINLESS STEEL DISK PLATES (SIZE AS REQUIRED) MOUNTED ON PARTITION OPPOSITE TO ACCESSORY SO AS TO ALLOW THROUGH BOLTING. (EXPOSED FASTENERS TO BE CARRIAGE BOLT HEADS ONLY.
10.290
10.290
10.282
22.404
REFER TO DETAIL ON AD9.1
1. INSTALL ACCESSORIES BACK TO BACK WHERE SHOWN.
10.285
2' - 10" @
TO BOTTOM OF MIRROR
MAX 3' - 4" A.F.F.
22.404
SURFACE MOUNTED - TOILET SEAT COVER DISPENSER B-221 (OFCI)
ACCESSORIES NOTES:
CL 10.283
10.287
REFER TO DETAIL ON AD9.1
10.286
1 1/2" 3' - 6"
4 / WEST
2
REFER TO DETAIL ON AD9.1 REFER TO DETAIL ON AD9.1
MAX
3 / SOUTH
4
1' - 6"
2 / EAST
TOILET 1 C139 A1_7.5 3
3' - 10"
08.121
10.282
1 / NORTH
7' - 11 1/2"
CL
24" MIN
MAX
/
MIN CLR
1/4" = 1'-0" REF.:
1' - 6"
CUSTODIAN - WEST
CL
SCALE:
CUSTODIAN/ WATER HEATER 1 C140 4 2 A1_7.5 3
4' - 4 3/4"
8' - 7 1/4"
WH
MOUNTING REQUIREMENTS SEE DETAIL REFERENCE
UNIT NAME
3. LIMIT THE PROJECTION OF A SURFACE OR SEMI-SURFACE MOUNTED ACCESSORY ITEM FROM ENCROACHING MORE THAN 3" FROM THE FACE OF THE WALL OR PARTITION, AND NO CLOSER THAN 1 1/2" TO THE TANGENT POINT OF THE GRAB BAR. 4. GRAB BAR LENGTHS ARE: FOR SIDE WALL 42" MIN. AND FOR BACK WALL 36" MIN.
7" - 9"
ABBREVIATIONS: TOP TOP OF OPERABLE PART FOF FACE OF FINISH FOP FACE OF PARTITION BF BARRIER FREE
GENERAL SHEET NOTES 1. KEYNOTE # INDICATES TOILET ROOM ACCESSORIES, SEE SCHEDULE ABOVE SCALE:
TOILET - WEST
SCALE:
1/4" = 1'-0" REF.:
/
5
TOILET 241 / CUSTODIAN 217
1/4" = 1'-0" REF.:
1 /A1_1.1
4
2. PROVIDE U-SHAPED OR WIRE DOOR PULLS BOTH SIDE OF ACCESSIBLE COMPARTMENT DOORS. 3. REFER TO TOILET ROOM ACCESSORIES LIST. LIMIT THE PROJECTION OF A SURFACE OR SEMISURFACE MOUNTED ACCESSORY ITEM FROM ENCROACHING MORE THAN 3" FROM THE FACE OF THE WALL OR PARTITION, AND NO CLOSER THAN 1 1/2" TO THE TANGENT POINT OF THE GRAB BAR. 4. FOR TOILET FIXTURES AND ACCESSORIES MOUNTING HEIGHT SEE SHEET AD9.2 5. VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. 6. ALL DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF COLUMN OR EDGE OF SLAB, U.N.O. 7.PROVIDE STUD BRACING AND SUPPORT FOR ALL WALL MOUNTED FIXTURES AND ACCESSORIES. PER DETAIL 20/S0.9 8. PROVIDE GROMMETS AND RINGS IN COUNTER TOPS 60"O.C. FOR POWER AND DATA
10.287
10
08.121
14
NOTE: ALL DIMENSIONS ARE TO FACE OF FINISHED FLOOR AND WALL FINISH, UNLESS OTHERWISE NOTED.
10.290
1 / NORTH
2 / EAST
3 / SOUTH
4 / WEST
1 1/2"
CL 12" MAX
CLR
1' - 6"
MIN
24" MIN
3' - 6"
4 SCALE:
6' - 7"
04-116805
8' - 8"
AT
FLS
N
No. C-20662 Exp. 3-31-19
ST
AC
D
ID
SS
E
OF
IA
4 / WEST
3' - 6 1/2"
A SED RCH I EN RUH
RN
3 / SOUTH
4' - 0"
IDENTIFICATION STAMP DIV OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES
AU
2 / EAST
3' - 6 1/2"
DSA File No:
6' - 7"
* CT TE
1 / NORTH
10.287
KEY PLAN L IC
10.290
2
30"x48"
1' - 6"
08.121
BLDG C
DA V
3
5' - 0 7/8"
/
CLR
1/4" = 1'-0" REF.:
5' - 0" MIN
WOMEN TOILET 285
CLR
WOMEN 1 C105 A1_7.5 3
30"x48"
NORTH
2
*
4
MEN 1 C104 A1_7.5 3
BLDG B
22.405
24' - 0"
CL
10.295
MIN
5' - 6"
3' - 0"
5' - 0"
CLR
22.401
32" DOOR
34" MIN
10.285
EQ
10.283
EQ
10.284
22.401
BLDG A
10.282
33" - 36"
22.405 1' - 4"
22.401
10.290 10.287
OPERABLE PARTS
10.285
MAX 40" TO
10.283
OF LAVATORY
2' - 10" @ TOP
10.282
5' - 0" MIN
A
CA L I
FO
DATE
EQ
EQ
STAMPS
28' - 8" 10.282
MAX 40" TO
10.287 10.282
10.283
22.401
2' - 9"
10.283
22.401
10.295
22.402
22.402
22.405
OPERABLE PARTS
10.290
10
14
22.405 BRANDING
ALVIN DUNN K-8 SCHOOL SCALE:
MEN TOILET 286 RRC PROJECT No. : 1-84-28E 12/11/2017 4:49:49 PM DRAWN BY:
CHECKED BY:
SCALE:
1/4" = 1'-0" REF.:
/
2
RESTROOM
1/4" = 1'-0"
1
3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
RRCARCH.COM
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
(951) 684 4664 /
5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010 (760) 438 5899
ENLARGED PLANS / INTERIOR ELEVATIONS
A1_7.5 1-84-28E
GENERAL NOTES 30"
30"
302 30"
12.351 4' - 7"
15" 302 29"
2 / EAST
1 / NORTH
1 1/2"
4' - 7"
15"
1.
VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION.
2.
ALL DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF COLUMN OR EDGE OF SLAB, U.N.O.
3.
PROVIDE STUD BRACING AND SUPPORT FOR ALL WALL MOUNTED FIXTURES AND ACCESSORIES. PER DETAIL 20/S0.9
4.
PROVIDE GROMMETS AND RINGS IN COUNTER TOPS 60"O.C. FOR POWER AND DATA
5.
FOR ADDITIONAL CASEWORK INFORMATION CASEWORK AND CASEWORK ANCHORAGE REFER TO DETAIL 2/AD7.2
6.
SEE DETAIL 15/AD-9.1 FOR ALL ACCESSIBLE FIXTURES AND ACCESSORIES INSTALLATION HEIGHTS AND CLEARANCE DIMENSIONS
1' - 4" 1' - 4"
7' - 3"
7' - 6"
06.411
22.405
2' - 10"
2' - 10"
4' - 6"
06.411
HEIGHT
OPEN BELOW
32"
212 24"
24"
DEPTH WIC # LENGTH
20' - 9 3/4"
09.650
32"
24" 212 34"
32"
24"
CASEWORK IDENTIFICATION
212 45"
24" 34"
32" 254 18"
24" 32" 155 43"
24" 254 15"
KEYNOTES 06.411 08.121 08.511 09.210 09.650 10.441
COUNTERTOP HOLLOW METAL DOOR AND FRAME, PER DOOR SCHEDULE ON SHEET A1_8.1 ALUMINUM WINDOW, PER WINDOW TYPES, SEE SHEET A1_8.1 5/8" GYPSUM BOARD PER WALL TYPE, WALL FINISH PER FINISH SCHEDULE, SEE SHEET A1_9.1 4" TOPSET RUBBER BASE, REFER TO SPECIFICATIONS SEMI-RECESSED FIRE EXTINGUISHER CABINET, SEE SHEETS AS-0.2 FOR ALL LOCATIONS, PER DETAIL 1/AD7.1 BANK CASEWORK SINK AND FAUCET, PER PLUMBING DRAWINGS
12.351 22.405
3 / SOUTH
4 / WEST
08.121
1 1/2"
12.351
1' - 4" T YP.
10.441
7' - 6"
8 " T Y P.
2' - 10"
4' - 6"
OPEN TO BEYOND
2' - 2" TYP. 20' - 9 3/4"
SCALE:
INSTRUMENT STORAGES C110
30"
1/4" = 1'-0" REF.:
1 /A1_9.5
2
15" 302 29"
1 / NORTH
2 / EAST
08.511 TYP.
OPEN TO BEYOND
32"
24"
32"
24" 212 36"
32"
24" 254 18"
32"
24" 212 34"
32"
24" 212 36"
32"
24"
09.650
10.441
254 18"
OPEN
32"
24" 254 18"
22.405
32"
24"
10.441
254 15"
BLDG B
212 36"
BLDG A 2' - 10"
2' - 10"
4' - 6"
06.411
NORTH
BLDG C
KEY PLAN DSA File No:
L IC
04-116805
AT
FLS
N
No. C-20662 Exp. 3-31-19
ST
AC
ID
SS
E
OF
IA
4 / WEST
RN
08.121
DA V
08.121
*
3 / SOUTH
AU
08.121 TYP.
A SED RCH I EN RUH
* CT TE
IDENTIFICATION STAMP DIV OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES
CA L I
FO
DATE
2' - 10"
STAMPS
BRANDING
ALVIN DUNN K-8 SCHOOL SCALE:
BAND C111 RRC PROJECT No. : 1-84-28E 12/11/2017 4:49:54 PM DRAWN BY:
CHECKED BY:
1/4" = 1'-0" REF.:
1 /A1_9.5
1
3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
RRCARCH.COM
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
(951) 684 4664 /
5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010 (760) 438 5899
INTERIOR ELEVATIONS
A1_7.6 1-84-28E
GENERAL NOTES 1.
VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION.
2.
ALL DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF COLUMN OR EDGE OF SLAB, U.N.O.
3.
PROVIDE STUD BRACING AND SUPPORT FOR ALL WALL MOUNTED FIXTURES AND ACCESSORIES. PER DETAIL 20/S0.9
4.
PROVIDE GROMMETS AND RINGS IN COUNTER TOPS 60"O.C. FOR POWER AND DATA
5.
FOR ADDITIONAL CASEWORK INFORMATION CASEWORK AND CASEWORK ANCHORAGE REFER TO DETAIL 2/AD7.2
6.
SEE DETAIL 15/AD-9.1 FOR ALL ACCESSIBLE FIXTURES AND ACCESSORIES INSTALLATION HEIGHTS AND CLEARANCE DIMENSIONS
1 / NORTH
HEIGHT
32"
212 24"
24"
DEPTH WIC # LENGTH
CASEWORK IDENTIFICATION
KEYNOTES 04.220 08.121 11.521 11.522 11.666
CONCRETE UNIT MASONRY, PER PLAN HOLLOW METAL DOOR AND FRAME, PER DOOR SCHEDULE ON SHEET A1_8.1 PROJECTION SCREEN WALL MOUNTED PROJECTOR, SEE DETAIL 2/AD7.1 & REFER TO SPECS WALL PAD
11.521 11.522
2 / EAST
15' - 0"
OPEN TO STAGE
OPEN TO STAIRS
OPEN TO STAIRS
OPEN TO RAMP
4' - 0"
4' - 0"
OPEN TO BEYOND
14' - 8"
4' - 0"
26' - 8"
BLDG A
BLDG B
3 / SOUTH
NORTH
BLDG C
KEY PLAN DSA File No:
RN
AT
SS
E
OF
IA
L IC
DA V
*
N
No. C-20662 Exp. 3-31-19
ST
FLS
ID
AU
04-116805 AC
A SED RCH I EN RUH
* CT TE
IDENTIFICATION STAMP DIV OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES
CA L I
FO
DATE STAMPS
BRANDING
08.121
ALVIN DUNN K-8 SCHOOL SCALE:
GYM - C101 RRC PROJECT No. : 1-84-28E 12/11/2017 4:50:00 PM DRAWN BY:
CHECKED BY:
1/4" = 1'-0" REF.:
1 /A1_9.5
1
3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
RRCARCH.COM
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
(951) 684 4664 /
5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010 (760) 438 5899
INTERIOR ELEVATIONS
A1_7.7 1-84-28E
GENERAL NOTES
4 / WEST
1.
VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION.
2.
ALL DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF COLUMN OR EDGE OF SLAB, U.N.O.
3.
PROVIDE STUD BRACING AND SUPPORT FOR ALL WALL MOUNTED FIXTURES AND ACCESSORIES. PER DETAIL 20/S0.9
4.
PROVIDE GROMMETS AND RINGS IN COUNTER TOPS 60"O.C. FOR POWER AND DATA
5.
FOR ADDITIONAL CASEWORK INFORMATION CASEWORK AND CASEWORK ANCHORAGE REFER TO DETAIL 2/AD7.2
6.
SEE DETAIL 15/AD-9.1 FOR ALL ACCESSIBLE FIXTURES AND ACCESSORIES INSTALLATION HEIGHTS AND CLEARANCE DIMENSIONS HEIGHT
32"
212 24"
24"
DEPTH WIC # LENGTH
CASEWORK IDENTIFICATION
KEYNOTES 08.121 09.210 10.441
HOLLOW METAL DOOR AND FRAME, PER DOOR SCHEDULE ON SHEET A1_8.1 5/8" GYPSUM BOARD PER WALL TYPE, WALL FINISH PER FINISH SCHEDULE, SEE SHEET A1_9.1 SEMI-RECESSED FIRE EXTINGUISHER CABINET, SEE SHEETS AS-0.2 FOR ALL LOCATIONS, PER DETAIL 1/AD7.1 PROJECTION SCREEN WALL MOUNTED PROJECTOR, SEE DETAIL 2/AD7.1 & REFER TO SPECS
11.521 11.522
OPEN TO BEYOND
08.121 SCALE:
GYM C101
1 / NORTH
1/4" = 1'-0" REF.:
1 /A1_9.5
2
2 / EAST
11.521
08.121
4' - 4"
5' - 10"
08.121
BLDG B
BLDG A
11.521
4 / WEST
BLDG C
NORTH
4 / WEST
KEY PLAN DSA File No:
15' - 11 253/256"
11' - 0"
RN
E
OF
IA
L IC
DA V
SS
CA L I
FO
DATE STAMPS
OPEN TO BEYOND
4' - 4"
OPEN TO BEYOND
4' - 4"
OPEN TO BEYOND 4' - 4"
AT
5' - 10"
FLS
N
No. C-20662 Exp. 3-31-19
ST
AC
*
04-116805
ID
AU
11.521
A SED RCH I EN RUH
* CT TE
IDENTIFICATION STAMP DIV OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES
BRANDING
10.441
26' - 8"
13' - 5 3/4"
ALVIN DUNN K-8 SCHOOL SCALE:
MPR STAGE C107 RRC PROJECT No. : 1-84-28E 12/11/2017 4:50:06 PM DRAWN BY:
CHECKED BY:
1/4" = 1'-0" REF.:
1 /A1_9.5
1
3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
RRCARCH.COM
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
(951) 684 4664 /
5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010 (760) 438 5899
INTERIOR ELEVATIONS
A1_7.8 1-84-28E
GENERAL NOTES 1.
VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION.
2.
ALL DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF COLUMN OR EDGE OF SLAB, U.N.O.
3.
PROVIDE STUD BRACING AND SUPPORT FOR ALL WALL MOUNTED FIXTURES AND ACCESSORIES. PER DETAIL 20/S0.9
4.
PROVIDE GROMMETS AND RINGS IN COUNTER TOPS 60"O.C. FOR POWER AND DATA
5.
FOR ADDITIONAL CASEWORK INFORMATION CASEWORK AND CASEWORK ANCHORAGE REFER TO DETAIL 2/AD7.2
6.
SEE DETAIL 15/AD-9.1 FOR ALL ACCESSIBLE FIXTURES AND ACCESSORIES INSTALLATION HEIGHTS AND CLEARANCE DIMENSIONS
KEYNOTES 08.121 09.210 10.441
HOLLOW METAL DOOR AND FRAME, PER DOOR SCHEDULE ON SHEET A1_8.1 5/8" GYPSUM BOARD PER WALL TYPE, WALL FINISH PER FINISH SCHEDULE, SEE SHEET A1_9.1 SEMI-RECESSED FIRE EXTINGUISHER CABINET, SEE SHEETS AS-0.2 FOR ALL LOCATIONS, PER DETAIL 1/AD7.1 ILLUMINATED EXIT SIGN
26.530
SCALE:
LOBBY C103
1/4" = 1'-0" REF.:
1 /A1_9.5
2
BLDG B
BLDG A
NORTH
BLDG C
KEY PLAN DSA File No:
10.441
08.121
2 / NORTH
4 / SOUTH
RN
SS
E
OF
IA
L IC
DA V
*
AT
3 / WEST
N
No. C-20662 Exp. 3-31-19
ST
08.121
FLS
ID
AU
04-116805 AC
A SED RCH I EN RUH
* CT TE
IDENTIFICATION STAMP DIV OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES
CA L I
FO
DATE STAMPS
10.441
BRANDING
ALVIN DUNN K-8 SCHOOL SCALE:
SPEED LINE C132 RRC PROJECT No. : 1-84-28E 12/11/2017 4:50:10 PM DRAWN BY:
CHECKED BY:
1/4" = 1'-0" REF.:
1 /A1_9.5
1
3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
RRCARCH.COM
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
(951) 684 4664 /
5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010 (760) 438 5899
INTERIOR ELEVATIONS
A1_7.9 1-84-28E
DOOR SCHEDULE ROOM NAME
DOOR TYPE
C100 C101 C102 C103A C103B C103C C104 C105 C106 C107A C107B C107C C111A C111B C112 C113 C114 C115 C116A C116B C117 C118 C119 C120 C121 C122 C123 C124A C124B C125A C125B C125C C125D C126 C127 C128 C129 C130 C131A C131B C132A C132B C132C C133A C133B C134 C137 C138 C139 C140
C100 C115 C101 C103 C103 C103 C104 C105 106B C110 C111 C107 C111 C108 C111 C111 C111 C115 C116 C116 C117 C118 C119 C120 C121 C119 C119 C124 C124 C126 C125 C106 106A C126 C127 C127 C129 C130 C101 C131 C101 C132 C132 C133 C141 C134 C137 C138 C139 C140
VESTIBULE CORRIDOR GYM LOBBY LOBBY LOBBY MEN WOMEN CUSTODIAL STORAGE INSTRUMENT STORAGE BAND (ELEVATED 36" ABOVE GYM FLOOR) MPR STAGE (ELEVATED 36" ABOVE GYM FLOOR) BAND (ELEVATED 36" ABOVE GYM FLOOR) VESTIBULE BAND (ELEVATED 36" ABOVE GYM FLOOR) BAND (ELEVATED 36" ABOVE GYM FLOOR) BAND (ELEVATED 36" ABOVE GYM FLOOR) CORRIDOR CUSTODIAL STORAGE CUSTODIAL STORAGE SPORTS STORAGE KOC OFFICE BOYS LOCKER ROOM SHOWER TOILET BOYS LOCKER ROOM BOYS LOCKER ROOM BOYS BATHROOM BOYS BATHROOM VESTIBULE GIRLS BATHROOM IDF FSA VESTIBULE GIRLS LOCKER ROOM GIRLS LOCKER ROOM COACH'S OFFICE TOILET GYM MPR STORAGE GYM SPEED LINE SPEED LINE KITCHEN SERVICE YARD OFFICE DRY STOR. ELECTRICAL/ DATA TOILET CUSTODIAN/ WATER HEATER
B I C B B B A A A J K E A J A A A B E 52 C A C A A A E E A E A A A E C A A A I C H G G A C A A A A A
WIDTH 5' 6' 6' 6' 6' 6' 3' 3' 3' 3' 6' 3' 3' 3' 3' 3' 3' 6' 3' 3' 6' 3' 6' 3' 3' 3' 3' 3' 3' 3' 3' 3' 3' 3' 6' 3' 3' 3' 6' 6' 3' 3' 3' 3' 6' 3' 3' 3' 3' 3'
-
8" 4" 4" 0" 0" 0" 0" 0" 0" 0" 4" 0" 0" 0" 0" 0" 0" 4" 0" 0" 4" 0" 0" 0" 0" 0" 0" 0" 0" 0" 0" 0" 0" 0" 0" 0" 0" 0" 4" 4" 0" 0" 0" 0" 0" 0" 0" 0" 0" 0"
7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 6' - 10" 6' - 10" 7' - 0" 7' - 0" 6' - 10" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0"
2" 1 3/4" 1 3/4" 2" 2" 2" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 2" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4"
FRAME
HDWR GROUP
PANIC HDWR
MATERIAL
FINISH
1 2 3 1 1 1 4 4 5 7 8 9 10 11 12 12 13 14 9 15 16 17 18 19 19 13 11 20 21 20 21 6 6 11 18 19 13 19 22 16 23 10 10 24 25 13 26 27 19 28
*
ALUM. HM HM ALUM. ALUM. ALUM. HM HM HM HM HM HM HM HM HM HM HM ALUM. HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM
M-4 P2 P2 M-4 M-4 M-4 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 M-4 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2
* * *
* *
*
*
*
* *
MATERIAL
FINISH
HM HM
P2 P2
FRAME MEASUREMENTS HEAD JAMB
4" 4"
2" 2"
HM HM HM HM HM HM HM HM HM HM HM
P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2
2" 2" 4" 4" 4" 2" 2" 4" 2" 2" 2"
2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2"
HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM
P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2
2" 4" 4" 2" 2" 2" 2" 2" 2" 2" 4" 2" 4" 2" 2" 2" 2" 2" 2" 2" 4" 4" 4"
2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2"
HM HM HM HM HM HM HM
P2 P2 P2 P2 P2 P2 P2
4" 4" 2" 2" 4" 2" 2"
2" 2" 2" 2" 2" 2" 2"
GENERAL NOTES
HEAD
DETAILS JAMB
SILL
FIRE RATING
11/AD5.1 1/AD5.1 1/AD5.1 11/AD5.1 11/AD5.1 11/AD5.1 2/ AD5.1 2/ AD5.1 1/AD5.1 6 / AD5.1 6/AD5.1 2/AD5.1 1/AD5.1 6 / AD5.1 2/ AD5.1 2/ AD5.1 2/ AD5.1 11/AD5.1 2/AD5.1 1/AD5.1 1/AD5.1 1/AD5.1 2/AD5.1 2/ AD5.1 2/ AD5.1 2/ AD5.1 2/AD5.1 2/AD5.1 1/AD5.1 2/AD5.1 1/AD5.1 2/ AD5.1 2/ AD5.1 2/AD5.1 2/AD5.1 2/ AD5.1 2/ AD5.1 2/ AD5.1 1/AD5.1 1/AD5.1 6/AD5.1 6/AD5.1 6/AD5.1 1/AD5.1 1/AD5.1 2/ AD5.1 2/ AD5.1 1/AD5.1 2/ AD5.1 2/ AD5.1
9/AD5.1 4/AD5.1 4/AD5.1 9/AD5.1 9/AD5.1 9/AD5.1 3/AD5.1 3/AD5.1 15/AD5.1 15/AD5.1 7/AD5.1 3/AD5.1 15/AD5.1 15/AD5.1 3/AD5.1 3/AD5.1 3/AD5.1 9/AD5.1 3/AD5.1 15/AD5.1 4/AD5.1 15/AD5.1 3/AD5.1 3/AD5.1 3/AD5.1 3/AD5.1 3/AD5.1 3/AD5.1 15/AD5.1 3/AD5.1 15/AD5.1 3/AD5.1 3/AD5.1 3/AD5.1 3/AD5.1 3/AD5.1 3/AD5.1 3/AD5.1 4/AD5.1 4/AD5.1 15/AD5.1 15/AD5.1 15/AD5.1 15/AD5.1 4/AD5.1 3/AD5.1 3/AD5.1 15/AD5.1 3/AD5.1 3/AD5.1
11/AD5.1 5/AD5.1 5/AD5.1 11/AD5.1 11/AD5.1 11/AD5.1 5/AD5.1 5/AD5.1 8/AD5.1 5/AD5.1 5/AD5.1 5/AD5.1 8/AD5.1 5/AD5.1 5/AD5.1 5/AD5.1 5/AD5.1 11/AD5.1 5/AD5.1 8/AD5.1 5/AD5.1 8/AD5.1 5/AD5.1 5/AD5.1 5/AD5.1 5/AD5.1 5/AD5.1 5/AD5.1 8/AD5.1 5/AD5.1 8/AD5.1 5/AD5.1 5/AD5.1 5/AD5.1 5/AD5.1 5/AD5.1 5/AD5.1 5/AD5.1 5/AD5.1 5/AD5.1 5/AD5.1 8/AD5.1 8/AD5.1 8/AD5.1 8/AD5.1 5/AD5.1 5/AD5.1 8/AD5.1 5/AD5.1 5/AD5.1
20 20 20 20 20 20 20 20 20 20 20 20
-
-
-
STC RATING
REMARKS
-
-
1.
SEE SHEET AD5.1 FOR HOLLOW METAL FRAME DETAILS.
2.
SET DOORS ADJACENT TO WALLS A MIN. OF 4" AWAY FROM WALL U.N.O.
3.
ALL GLAZING IN DOORS, AND WINDOWS BELOW 8'-0" A.F.F., ARE TEMPERED OR AS REQUIRED BY SECTION 2406 OF THE 2016 CBC.
4.
PROVIDE DOOR STOPS AT ALL INTERIOR DOORS. PROVIDE BACKING PLATE PER STRUCTURAL DRAWINGS.
5.
ALL EXTERIOR DOORS ARE TO SWING OUT AND OPEN TO A MIN. OF 110 DEGREES FROM ITS CLOSED POSITION WHERE POSSIBLE, U.N.O. - EXCEPTION: WHERE TACTILE SIGNAGE IS LOCATED ON HINGE SIDE OF DOOR, DOORS TO HAVE A 90 DEGREE SWING LIMIT.
6.
ALL EXTERIOR DOORS SHALL HAVE A POLYSTYRENE CORE (THERMAL RESISTANCE).
7.
PROVIDE AIR SEALS/WEATHER STRIPPING AT ALL EXTERIOR DOORS TO CONDITIONED SPACES.
8.
ALL FLOOR MATERIAL CHANGE SHALL BE LOCATED UNDER THE CENTERLINE OF DOOR WHERE OCCURS, TYP.
9.
ALL EXTERIOR DOORS SHALL BE OPERABLE FROM THE INTERIOR WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. DEAD BOLTS ARE ONLY PERMITTED WHEN OPERABLE WITH A SINGLE EFFORT LEVER TYPE HARDWARE.
10.
HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE MOUNTED 34"-48" A.F.F.
11.
ALL DOORS SHALL BE LOCKABLE FROM THE INTERIOR SIDE.
12.
PER SECTION 1010.1.10 IN THE CBC 2016, DOOR SERVING ROOMS OR SPACES WITH AN OCCUPANT LOAD OF 50 OR MORE ARE REQUIRED TO HAVE PANIC HARDWARE OR FIRE EXIT HARDWARE.
13.
PER CBC 2016 11B-404.2.5, THRESHOLDS SHALL BE 1/2" HIGH MAX., SEE SHEET AD5.1 FOR DETAILS.
14.
THE BOTTOM 10" OF ALL DOORS EXTENDING THE FULL WIDTH SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. CBC 2016 11B-404.2.10
15.
MAXIMUM EFFORT TO OPERATE ALL DOORS SHALL NOT EXCEED 5 LBS FOR BOTH EXTERIOR AND INTERIOR DOORS. FIRE DOORS SHALL NOT EXCEED 15 LBS. CBC 2016 11B-404.2.9
16.
REFER TO SPECIFICATION SECTION 08 71 00 FOR DOOR HARDWARE INFORMATION.
ABBREVIATIONS HM
HOLLOW METAL
STL
STEEL
GALV.
GALVANIZED
PSG
PAINT: SEMI-GLOSS
T
T
T
T
38" MAX.
ROOM No.
DOOR
36" MIN.
DOOR No.
DOOR MEASUREMENTS HEIGHT THICKNESS
STAINLESS STEEL 12" KICK PLATE (ON INTERIOR SIDE)
(DOUBLE LITE) DOOR TYPE "B"
(FLUSH) DOOR TYPE "A"
STAINLESS STEEL 12" KICK PLATE (ON INTERIOR SIDE)
(SINGLE LITE) DOOR TYPE "D"
38" MAX.
12"
T
36" MIN.
38" MAX.
36" MIN.
T
(DOUBLE FLUSH) DOOR TYPE "C"
SCALE:
DOOR TYPES
1/4" = 1'-0" /
REF.:
BLDG B
BLDG A
NORTH
BLDG C
KEY PLAN DSA File No:
2' - 3"
3' - 0"
2' - 3"
3' - 0"
2' - 3"
3' - 0"
2' - 3"
3' - 2"
RN
E
OF
IA
L IC
DA V
*
SS
CA L I
FO
DATE
7' - 4"
4' - 8"
AT
2' - 10"
FLS
N
No. C-20662 Exp. 3-31-19
ST
AC
ID
AU
04-116805
24' - 0"
A SED RCH I EN RUH
* CT TE
IDENTIFICATION STAMP DIV OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES
STAMPS
3' - 8"
3' - 9 1/2"
3' - 8"
8' - 4"
2' - 0" 6' - 4"
7' - 0"
8' - 8"
3' - 0"
F.F.
3' - 4"
4' - 0" 4' - 8"
7' - 6"
2' - 6"
4' - 8"
8' - 8"
5' - 0"
4' - 0"
4' - 11"
BRANDING
E
D
C
B
A
ALVIN DUNN K-8 SCHOOL 3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
RRC PROJECT No. : 1-84-28E 12/11/2017 4:50:14 PM DRAWN BY:
CHECKED BY:
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
RRCARCH.COM
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
(951) 684 4664 /
5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010 (760) 438 5899
DETAILS DOOR & WINDOW SCHEDULE
A1_8.1 1-84-28E
GENERAL NOTES 1.
REFER TO SIGNAGE SCHEDULE IN SECTION 10 14 00 FOR MORE INFORMATION.
2.
SEE SHEET AD1.3 FOR SIGNAGE ATTACHMENTS AND LOCATIONS
3.
ALL DOORS TO HAVE A 90 DEGREE SWING LIMIT WHERE TACTILE SIGNAGE IS LOCATED ON HINGE SIDE OF DOOR.
4.
TYPICAL AT PAIRS OF DOORS: WHEN POSSIBLE TACTILE SIGNAGE SHALL BE PLACED AT RIGHT SIDE OF DOORS.
AWNING ABOVE
SIGNAGE SCHEDULE
PARKING ACCESS 1' - 10"
MEN
WOMEN
WP
ROOF
FINISH LEGEND WP
LOBBY
BATTERY STORAGE
CAMPUS ACCESS
SCON: SEALED CONCRETE
DISPLAY CABINET
CPT: CARPET WP
DN
EP: EPOXY DN
AWNING ABOVE
MON: MONDO FLOORING WITH INTRIGAL STRIPPING
SERVICE YARD
WP
COMPACTING MACHINE
MPR STAGE (ELEVATED 36" ABOVE GYM FLOOR)
BLEACHERS
FRP1 8' HIGH
GYM
FRP2 42" HIGH AWP-3 / TWP-1
BASKETBALL COURT ELECTRICAL/ DATA
8' HIGH WALL PADS
ACCOUSTICAL PANELING ABOVE WALL PADS
DRY STOR.
DN
WH
CUSTODIAN/ WATER HEATER
FRP1
5' - 0" FREEZER TOILET
UP
P.E. STORAGE
WALK-IN REF
AWNING ABOVE FRP1
ANS
WP
VESTIBULE VESTIBULE
GIRLS BATHROOM
BLDG A
CUSTODIAL STORAGE
BOYS BATHROOM
KITCHEN MPR STORAGE
FRP2
SPEED LINE
BOYS LOCKER ROOM
W
BLDG B
SPORTS STORAGE
D
OFFICE
BLDG C COACH'S OFFICE
COACH'S OFFICE
TOILET
NORTH
TOILET
KOC OFFICE
KEY PLAN
FLS
SS
DA V
*
E
OF
IA
RN
AC
AWNING ABOVE
AU
AWNING ABOVE
N
AT
CANOPY ABOVE
ID
No. C-20662 Exp. 3-31-19
ST
04-116805
A SED RCH I EN RUH
* CT TE
IDENTIFICATION STAMP DIV OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES
L IC
DSA File No:
CA L I
FO
DATE
NORTH
STAMPS
BRANDING
ALVIN DUNN K-8 SCHOOL SCALE:
FINISH PLAN RRC PROJECT No. : 1-84-28E 12/11/2017 4:50:35 PM DRAWN BY:
CHECKED BY:
1/8" = 1'-0"
1
3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
RRCARCH.COM
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
(951) 684 4664 /
5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010 (760) 438 5899
MPR FINISHES PLAN
A1_9.2 1-84-28E
GENERAL NOTES 1.
REFER TO SIGNAGE SCHEDULE IN SECTION 10 14 00 FOR MORE INFORMATION.
2.
SEE SHEET AD9.1 FOR SIGNAGE ATTACHMENTS AND LOCATIONS
3.
ALL DOORS TO HAVE A 90 DEGREE SWING LIMIT WHERE TACTILE SIGNAGE IS LOCATED ON HINGE SIDE OF DOOR.
4.
TYPICAL AT PAIRS OF DOORS: WHEN POSSIBLE TACTILE SIGNAGE SHALL BE PLACED AT RIGHT SIDE OF DOORS.
A IDF C106
H
J
SIGNAGE SCHEDULE
WOMEN C105
MEN C104 N F
N
VESTIBULE C100
A B B1 C C1 D D1 E F G H J K L M N
FSA
F
G
K
E M
G
B
C
B1
C1
CUSTODIAL STORAGE 106B
LOBBY C103
H
BATTERY STORAGE C150
J F N
ROOM IDENTIFICATION, PER DETAIL 26/AD9.1 BOY'S RESTROOM IDENTIFICATION, PER DETAIL 23/AD9.1 BOY'S RESTROOM DOOR IDENTIFICATION, PER DETAIL 12/AD9.1 GIRL'S RESTROOM IDENTIFICATION, PER DETAIL 24/AD9.1 GIRL'S RESTROOM DOOR IDENTIFICATION, PER DETAIL 12/AD9.1 ALL GENDER RESTROOM IDENTIFICATION, PER DETAIL 25/AD9.1 ALL GENDER RESTROOM DOOR IDENTIFICATION, PER DETAIL 7/AD9.1 EVACUATION SIGN, PER DETAIL 11/AD9.1 EXIT DOOR SIGN, PER DETAIL 8/AD9.1 EXIT ROUTE SIGN, PER DETAIL 8/AD9.1 INTERNATIONAL SYMBOL OF ACCESSIBLE ENTRY, PER DETAIL 10/AD9.1 MAIN USE/UTILITY ID, PER DETAIL 27/AD9.1 FIRE RISER, PER DETAIL 16/AD9.1 STAIR - STAGE, PER DETAIL 17/AD9.1 DIRECTORY SIGNAGE, PER DETAIL 3/AD9.1 MAXIMUM OCCUPANCY SIGN, PER DETAIL 4/AD9.1
DISPLAY CABINET
DN L
INSTRUMENT STORAGE C110 A
A
DN
COMPACTING MACHINE
A
F
SERVICE YARD C141
MPR STAGE (ELEVATED 36" ABOVE GYM FLOOR) C107
J
A
A BAND (ELEVATED 36" ABOVE GYM FLOOR) C111
GYM C101 F ELECTRICAL/ DATA C138
BASKETBALL COURT
A
DRY STOR. C137
DN
WH J FREEZER C136
A
L
CUSTODIAN/ WATER HEATER C140
A
A
A
A
D1 TOILET C139
D
PRACTICE C112
H
UP
PRACTICE C113
OFFICE C114
STAGE ACCESS
J
A
P.E. STORAGE C102
WALK-IN REF C135
F
CORRIDOR C115 E
ANS
A
A
VESTIBULE C126 A
C1
B1
C
B
VESTIBULE C123
F GIRLS BATHROOM C125
SPEED LINE C132 MPR STORAGE C131
CUSTODIAL STORAGE C116
F
N
KITCHEN C133
J
N
BOYS BATHROOM C124
BLDG A
GIRLS LOCKER ROOM C127
BOYS LOCKER ROOM C119 SPORTS STORAGE C117
N
A
F
TOILET C130
COACH'S OFFICE C129
F
D1
F COACH'S OFFICE C122
D
KOC OFFICE C118
BLDG C
NORTH
F
TOILET C121
D1 D
A A
SHOWER C120
BLDG B
A
SHOWER C128
W
A
J
D
OFFICE C134
J
KEY PLAN
A A
A
A
E
IA
*
DA V
RN
SS
AU
FLS
N
AT
AC
ID
No. C-20662 Exp. 3-31-19
ST
04-116805
A SED RCH I EN RUH
* CT TE
IDENTIFICATION STAMP DIV OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES
L IC
DSA File No:
OF
CA L I
FO
DATE STAMPS
BRANDING
ALVIN DUNN K-8 SCHOOL SCALE:
FLOOR PLAN - SIGNAGE PLAN RRC PROJECT No. : 1-84-28E 12/12/2017 6:31:34 PM DRAWN BY:
CHECKED BY:
1/8" = 1'-0"
1
3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
RRCARCH.COM
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
(951) 684 4664 /
5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010 (760) 438 5899
MPR SIGNAGE PLAN
A1_9.4 1-84-28E
1 1/2" O.D. PAINTED PIPE HANDRAIL, COLOR TO BE SELECTED BY ARCHITECT. 1 1/2" O.D. PAINTED PIPE HANDRAIL, COLOR TO BE SELECTED BY ARCHITECT
HANDRAIL ATTACHED TO GUARDRAIL POST. SEE DET. 20/-
HANDRAIL ATTACHED TO WALL 18 AD2.1
TYP. 1' - 0"
EQ
EQ
EQ
EQ
LEVEL EQ
EQ
4' - 10"
EQ
EQ
EQ
EQ
EQ
2' - 0"
EQ
EQ
EQ
5' - 0" MAX. TYP.
FIN. GRADE OR SLAB; SEE PLANS
T + 12"
2' - 10"
Sim
AD2.1
TYP.
3 AD2.1
1' - 6"
1' - 6"
3' - 0"
2' - 10"
2
3' - 6"
2' - 10"
2' - 10"
2' - 10"
EQ
EQ
(5' - 0" MAX. TYP.)
18' - 0"
EQ
2' - 10"
EQ
EQ
3' - 0"
EQ
EQ
2' - 10"
EQ
4' - 10"
3' - 6"
FIN. GRADE OR SLAB; SEE PLANS
5' - 0"
17' - 3"
8' - 6"
18' - 0"
7' - 6"
5' - 0"
17' - 3"
8' - 6"
SCALE:
TYPICAL RAMP
SCALE:
1/4" = 1'-0" REF.:
/
16
TYPICAL RAMP
1
1/4" = 1'-0" /
REF.:
PER PLAN 5 EQ THREADS EQ
EQ
(4'-0" MAX., TYP.)
1 1/2" O.D. PAINTED PIPE HANDRAIL, COLOR TO BE SELECTED BY ARCHITECT.
12" LEVEL
12+T"
MIN.
18 AD2.1
2' - 10"
23" MIN.
TYP. 12" LEVEL "T" "R" (7" MAX.)
2' - 10"
2' - 10"
12"
MIN.
3" . R CL
2"
14 AD2.1
12" MIN.
2" 1/ . R CL
6 EQ RISERS
(11" MIN.)
5
3' - 0"
MIN.
FIN. GRADE OR SLAB; SEE PLANS
CONC. STAIRS PER STRUCT. DET.
#4 CONT. T&B
TYP.
SCALE:
EXTERIOR STAIRS 3 1/2" MAX.
T + 12"
PER PLAN
LEVEL
5 EQ THREADS
1 1/2" O.D. PAINTED METAL HANDRAIL, SCHEDULE 40
MIN.
12"
14 AD2.1
2"
FS PER CIVIL
CONC. STAIRS PER STRUCT. DET.
"R" (7" MAX.)
4" MAX. TYP.
2' - 10"
(2) #10 FHMS C.S. FROM BELOW TYP.
2' - 10"
1' - 0"
(11" MIN.)
2" 1/ . R CL
1/2" MAX.
MIN.
FS PER CIVIL
5
FIN. GRADE OR SLAB; SEE PLANS
"T"
3" . R CL
(3) ITW BUILDEX 3/16” DIA. TAPCON SCREW w/ 1 ½” MIN. EMBED. (INSTALL PER ICC ESR-1671)
6 EQ. RISERS
5'-0" O.C. MAX. TYP.
3' - 0"
3' - 6"
PLAN 6"
12" LEVEL
3' - 6"
(2) #10 FHMS C.S. FROM BELOW TYP.
2' - 10"
1 1/2" O.D. PAINTED METAL HANDRAIL, SCHEDULE 40
(3) ITW BUILDEX 3/16” DIA. TAPCON SCREW w/ 1 ½” MIN. EMBED. (INSTALL PER ICC ESR-1671) WALL PER PLAN
1 /A1_7.1
1 1/2" O.D. PAINTED PIPE HANDRAIL, COLOR TO BE SELECTED BY ARCHITECT. FOR RAILING DETAIL SEE DETAIL 25/-
1 1/2"
1 1/2"
2"
SECTION
2
1/2" = 1'-0" REF.:
#4 CONT. T&B
TYP.
12" MIN.
SCALE:
TYP. HANDRAIL DETAIL
SCALE:
3" = 1'-0" REF.:
2 /AD2.1
18
EXTERIOR STAIRS 1"
3
1/2" = 1'-0" REF.:
3 /A1_7.2
11" MIN. (SEE PLANS)
1/2" R
2"
EPOXY PAINTED GROOVES W/ CONTRASTING (70% MIN) COLOR, TYPICAL PAINTED THE FULL 2" WIDTH
3/4" R
1/2" R
3/4"
3/4" R
(4" MIN)
@ EXTERIOR LOCATIONS SLOPE TO DRAIN, TYPICAL 1/4" PER FOOT MAXIMUM
EQUAL (7" MAX)
1/4"
3/4"
1"
1/4"
SCALE:
STAIR NOSING
GALVANIZED 1 1/2" DIA. STEEL HORIZ. GALVANIZED 1 1/2" DIA. STEEL HANDRAIL
GALVANIZED 1-1/2" DIA. STEEL BALUSTER @ 48" O.C. MAX.
AC
1/4"
1 1/2" NOMINAL O.D. PIPE GALVANIZED
FLS
SS
N
No. C-20662 Exp. 3-31-19
E
IA
L IC
ID
RN
04-116805
RETURN END TO WALL
DA V
1 1/2"
*
> 4"
1 1/2"
1 1/2"
GALVANIZED 1-1/2" DIA. STEEL GUARDRAIL
A SED RCH I EN RUH
AT
3 1/2"
IDENTIFICATION STAMP DIV OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES
ST
GALVANIZED 1 1/2" DIA. STEEL HORIZ.
3/16" TYP.
DSA File No:
AU
GALVANIZED 1-1/2" DIA. STEEL GUARDRAIL
14 * CT TE
48" O.C. MAX.
2 /AD2.1
ALL HAND RAILINGS & GAURDRAILINGS SHALL BE 1 1/2" DIA. SCHEDULE 40
1 1/2"
MAX.
1 1/2"
3" = 1'-0" REF.:
OF
CA L I
FO
DATE STAMPS
4"
ATTACH W/ (I) HILTI 1/2" DIA. HILTI KWIK BOLT "TZ" ANCHOR ICC-ESR-1917
CONCRETE OR CMU WALL
MAX.
CONCRETE FLOOR OVER METAL DECKING, PER STRUCTURAL 3"
MIN.
BRACKETS @ 4'-0" O/C MAX
GALVANIZED 1 1/2" DIA. STEEL HORIZ.
MAX. MAX.
3"
3"
GALVANIZED 1/2" DIA. STEEL VERTICAL PICKETS @ 4" O.C.
4"
1 1/2"
GALVANIZED 1/2" DIA. STEEL VERTICAL PICKETS @ 4" O.C., PER DETAIL 20/AD2.1 GALVANIZED 1 1/2" DIA. STEEL HORIZ.
3' - 6"
3' - 1"
GALVANIZED 1-1/2" DIA. STEEL BALUSTER @ 48" O.C. MAX.
BRANDING
ALVIN DUNN K-8 SCHOOL SCALE:
GUARDRAIL AT LANDING RRC PROJECT No. : 1-84-28E 12/11/2017 6:52:45 PM DRAWN BY:
CHECKED BY:
SCALE:
1" = 1'-0" REF.:
/
25
GUARDRAIL AT STAGE RAMP
SCALE:
1" = 1'-0" REF.:
3 /A1_7.2
20
HANDRAIL ATTACHMENT
3" = 1'-0" REF.:
2 /A1_7.2
15
3697 LA MIRADA DR., SAN MARCOS, CA 92078 SAN MARCOS UNIFIED SCHOOL DISTRICT
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
RRCARCH.COM
REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________ REVISION No.______ DATE________ DESCRIPTION_______________________________________________________________________
3775 TENTH STREET, RIVERSIDE CALIFORNIA 92501
(951) 684 4664 /
5751 PALMER WAY, SUITE C, CARLSBAD CALIFORNIA 92010 (760) 438 5899
VERTICAL CIRCULATION
AD2.1 1-84-28E