FLAME RETARDANT WORKWEAR
ANTIFLAME
NEW!
Soft and lightweight flame retardant workwear - Designed for a functional and safe day. Approved according to EN ISO: 11612 Antiflame (class A1, B1, C1, E3, F1), 1149-5 Electrostatic properties, 11611 Welding (class 1 A1) and 61482-1-2 Electric Arc (class 1). Quality: 99 % cotton/1 % carbon (antistatic), 350g/m².
12212 6 WORK JACKET
12211 6 WORK TROUSERS
90503 7 HOLSTER POCKETS
12210 6 COVERALL
Expansion in the back, velcro adjuster at wrist, chest pockets, the left one with hidden mobile phone pocket and the right with ID pocket. Front pockets with Velcro flap.Extra long back.
Front pockets, back pocket with Velcro flap, thigh pocket with Velcro flap on left side, ruler pocket on right side. Knee pad pockets for 29 cm knee pads.
Holster pockets for attatchment to belt, rooms for tools, nails etc. Flame retardant material (not certified). Pair.
Expansion in the back, elastic in waist and Velcro adjuster at wrist. Chest pockets, the left one with hidden mobile phone pocket and the right with ID pocket. Front pockets with Velcro flap, back pocket with Velcro flap, thigh pocket with Velcro flap on left side and ruler pocket on right side. Kneepad pockets for 29 cm kneepads.
GREY ART. NO: 12216 6 SIZE: S–3XL
GREY ART. N0: 12211 6
QUALITY: 99 % cotton/1 % carbon(antistatisc), 350g/m².
SIZE: 44–64
GREY ART. NO: 90503 7 SIZE: ONE SIZE
GREY ART. NO: 12210 6 SIZE: S–3XL
ANTIFLAME
NEW!
Hi-Vis & Flame retardant workwear - extremely light and soft quality - and all practical details in the right place! Approved according to EN ISO: 11612 Antiflame (class A1, B1, C1, F1), 1149-5 Electrostatic properties, 11611 Welding (class 1 A1), 61482-1-2 Electric arc (class 1) and 471 Hi-Vis Quality: Yellow: TenCate ZZ9534, 74 % cotton, 25 % polyester, 1 % carbon, 300 g/m². Dark grey: 350 g/ m². Sto-Nor flame retardant retro reflective material.
90503 7 HOLSTER POCKETS Holster pockets for attatchment to belt, rooms for tools, nails etc. Flame retardant material (not certified). Pair. QUALITY: 99 % cotton/1 % carbon(antistatisc), 350g/m². GREY ART. NO: 90503 7 SIZE: ONE SIZE
23116 6 WORK JACKET CL. 2 Expansion in the back, velcro adjuster at wrist, chest pockets, the left one with hidden mobile phone pocket and the right with ID pocket. Front pockets with Velcro flap.Extra long back. YELLOW/DARK GREY ART. NO: 23116 6 SIZE: XS–4XL
21816 6 CRAFSMAN TROUSERS CL. 1 Holster pockets and front pockets, Back pocket w/Velcro flap, Thigh pocket with Velcro flap on left side, Ruler pocket on right side. Knee pad pockets for 29 cm knee pads. DARK GREY/YELLOW ART. NO: 21816 6 SIZE: 44-64
21716 6 ARBEIDSBUKSE KL. 1
20216 6 KJELEDRESS KL. 3
Front pockets, back pocket with Velcro flap, thigh pocket with Velcro flap on left side, ruler pocket on right side. Knee pad pockets for 29 cm knee pads.
Expansion in the back, elastic in waist and Velcro adjuster at wrist.Chest pockets, the left one with hidden mobile phone pocket and the right with ID pocket. Front pockets with Velcro flap, back pocket with Velcro flap, thigh pocket with Velcro flap on left side and ruler pocket on right side. Kneepad pockets for 29 cm kneepads.
DARK GREY/YELLOW ART. NO: 21716 6
YELLOW/DARK GREY ART. NO: 20216 6
SIZE: 44–64
SIZE: XS–4XL
OFFSHORE
NEW!
Offshore - softer and more durable fabric! Approved according to EN ISO: 11612 Antiflame (class A1, B1, C1, F1) Quality: 100 % Flameshield Satin, 350 g/m².
80806 8 OFFSHORE WORK JACKET
80806 8 OFFSHORE WORK TROUSERS
80805 8 OFFSHORE COVERALL
Expansion fold in back, chest pockets, front pockets.
Slash pockets in front, back pockets with flap, knee pad pockets, thigh pocket, folding rule pocket, phone pocket, elastic at waist, reflective trim on leg.
Expansion fold in back, chest pockets, inside pocket, pen pocket, sleeve pocket, slash pockets, back pockets with flap, access opening, knee pad pockets, thigh pocket, phone pocket and folding rule pocket.
SIZE: 46–64
SIZE: S–3XL
SIZE: S-3XL
FLAME RETARDANT EN ISO 11612:2008 This standard specifies the requirements for protective clothing against heat and flames. Protective clothing which is claimed to comply with this European standard shall meet the limited flame spread requirement and at least one other heat transmission performance requirement. The clothing should only be used for the purposes indicated. To protect the whole body, the entire body should be covered, eg. jacket and trouser to be worn together. In the event of accidental splash or chemical of flammable liquids or molten metal on clothing whilst being worn, the wearer shall immediately withdraw and carefully remove the garments. The clothing shall then be cleaned or removed from service. In the event of molten metal, garment, if worn next to the skin, may not eliminate all risks of burn. EN ISO 11612 Flame retardant workwear from Synfiber provide the following minimum protection: A1, B1, C1, E1. This garment’s classification is specified inside the product. Electrostatic properties EN 1149-5:2008 The garments are certified in compliance with EN 1149-5, which specifies the requirements concerning product standards for anti-static garments. The garments reduces the risk of explosion in areas where it is, or may occur, high concentrations of gases and / or combustible liquids. The fabric is tested in compliance with EN 1149-3. The anti-static features are achieved through carbon threads woven into the fabric, consequently the antistatic properties are permanent. Persons wearing antistatic garments should be properly earthed by wearing antistatic footwear. (Unless they are earthed directly.) Welding EN ISO 11611:2007 Garments complies with the welding norm. Garments made of 350 g/m² weight fabric are EN ISO 11611 class 2 certified. Garments made in lighter fabric meet the requirements of EN ISO 11611 class 1. The difference between the two classes is the amount of sparks and the amount of radiant heat the garments can withstand. Metal buttons etc, pockets and other openings shall be covered. To provide the specified level of protection, jacket and trousers should be worn together and must overlap by at least 20 cm. The fabric is flame retardant, meaning it will stop burning as soon as the flame source is removed. Additional partial body protection may be required, e.g. for welding overhead. Garment is intended to protect against brief inadvertent contact with live parts of an arc welding circuit. Additional layers will be required where there is an increased risk of electric shock. An increase in the oxygen content of the air will reduce considerably the protection against flame. Care should be taken when welding in confined spaces. Electric Arc IEC/EN 61482:2007 Workwear certified in compliance with EN 61482-1-2 protection against electric arc. For personnel working in vicinity of high-voltage conducting facilities at risk of arc electric explosions. The temperature of an electric arc can reach thousands of degrees, hence it is important that garments are flame retardant. Both fabric and garments in Synfiber’s flame retardant series are tested for protection against electric arc in compliance with the norm. Unlined garment class 1 (4kA), lined garment class 2 (7kA). Recommendations for use may vary from the above. HIGH VISIBILITY EN 471:2003+A1:2207 All garments have care instructions, and it is important that these are followed carefully. Be particularly aware that gar- ments made of fluorescent material can become discoloured and lose their properties if these instructions are not followed. Classification This garment complies with the requirements concerning ample visibility in exposed situations under all sorts of lighting conditions. The upper number placed to the right of the EN-label indicates the class of protection for the garment and the lower number specifies the effect of the retro reflective material. X: Classification of the fluorescent fabric and retroreflective fabric’s area (max. class 3). Y: Classification of the reflective material’s effect (max. class 2). Minimum area per m² garment: Class 3: 0.80 m² fluorescent fabric and 0,20 m² retro reflective material Class 2: 0,50 m² fluorescent fabric and 0,13 m² retro reflective material Class 1: 0,14 m² fluorescent fabric and 0,10 m² retro reflective material Classification is specified inside the product.
Code
Area
Explanation
A1: Surface test Limited flame A2:Test from the spread edge of the fabric
IISO 15025: Average afterglow time and afterflame time shall be maximum 2 sec. The seams are also tested.
B1: 4- <10 s B2: 10- <20 s B3: min. 20 s
Convective heat
ISO 9151: Single or multilayer garments and/or garment combinations. Convective heat occurs when the air near the heat source is heated.
C1: C2: C3: C4:
Radiant heat
ISO 6942: Single or multlayer garments and/or clothing assem-blies. Radiant heat is beams passing through the air as invisible light. When the rays hit an object, it becomes hot.
7- <20 sec 20- <50 sec 50- <95 sec min. 95 sec
E1: 60g-<.120 g Molten iron E2:120 g–<.200 g splash E3: min. 200 g
ISO 9185: Level of protection against molten iron. Indicates how many grams of molten iron splash the garments protect against.
F1: 5- <10 sec F2: 10- <15 sec F3: min. 15 sec
ISO 12127: Level of protection against contact heat.Indicates number of seconds you are protected when in contact with a heat source at 250 °C.
Contact heat
Professor Birkelands vei 35 P.O.Box 12 Leirdal NO-1008 OSLO Norway Tel: +47 23 17 75 00 kundeservice@synfiber.no www.synfiber.no