Portfolio overview Intelligent and energy-efficient ventilation, heating & cooling solutions
With 230 engineers, spread across 23 development teams in 18 countries and 9 technology centers on three continents, Systemair is a leader of product development in ventilation, heating and cooling.
Improving the climate for your business Systemair’s products and solutions create a comfortable and healthy indoor climate in homes, workplaces, public areas and on ships.
Our brand promise WE PUT OUR CUSTOMER FIRST We meet our customers expectations and offer products and solutions based on their needs. From concept to completion, we are at our customers side.
WE SIMPLIFY We make our customers’ jobs easier by turning complex systems into smart, easy and sustainable solutions.
WE GUIDE We share our deep knowledge and experience to give our customers advice and guidance. This makes us a trustworthy partner.
TABLE OF CONTENTS PORTFOLIO OVERVIEW SELECTION TOOLS FANS AIR HANDLING UNITS AIR CONDITIONING AIR DISTRIBUTION PRODUCTS FIRE SAFETY PRODUCTS RESIDENTIAL VENTILATION HEATING PRODUCTS RESEARCH & DEVELOPMENT GLOBAL PRESENCE 2 systemair
4 6 8 20 36 42 46 48 50 58 60
Systemair product solutions are: • Innovative and energy efficient • Simple to choose, install and maintain • Robust, stable and standardized • Performance tested, measured and documented in every detail.
systemair
3
Systemair is present everywhere in society
Systemair’s products and solutions are everywhere in society. We contribute to an optimal and healthy indoor climate in most places where people move around in day-to-day life – in the home, offices, industrial premises, hospitals, swimming pool halls, tunnels, airports etc. We do this with a conviction that good quality air makes for a better quality of life for people. We also do it in an increasingly energy-efficient way, in order to help bring about effective energy management in society.
Offices
Swimming pool halls
In office environments, there is a major need for clean air and a pleasant temperature, since they affect the way we feel and how well we perform. Systemair creates a healthy indoor climate in offices and helps customers achieve good energy management. We also offer fire gas fans and exhaust fans, and our air handling units, chillers and fans are certified by Eurovent.
Swimming pool halls make great demands of ventilation. Part of the task is to create a comfortable indoor climate for users, and part is to ensure continuous dehumidification to protect the building from the harmful effects of damp over time. Our units offer reliable, fully-automated ventilation, dehumidification and heating to order – in the most economical way.
Industrial
Data centres
In industrial enterprises, large factory area need to be both heated and ventilated. Our products, evacuate impure air and ensure that working areas are kept at the right temperature. Our solutions help establish a healthy work environment, which in turn creates the conditions for higher productivity.
An ever-growing need for storage capacity and increasingly compact equipment are creating a greater need for cooling. We supply both air handling units and precision chillers (close-control units) that provide energyand cost-efficient cooling in data centres.
Residential
Schools and public environments
Marine, oil and gas
Multi-storey/underground car parks
Hospitals and the p harmaceutical industry
Tunnels
Fresh air in the home is important to our well-being. Systemair’s air handling units with balanced ventilation feature heat recovery and are ideally suited to home and small offices. Our units have humidity and temperature control as standard.
Schools and public buildings recuires custom ventilation and air conditioning systems. With a broad product range, we create optimal system solutions that help to ensure a healthy indoor climate in public environments and the well-being of children at school all day.
A healthy indoor climate is crucial to both comfort and safety on board ships, whether provided by air conditioning on cruise liners, cargo hold ventilation in cargo vessels or exhaust air ventilation in ships’ engine rooms. The bar for quality is set high, given that conditions are often challenging. Our stainless steel, acid-proof units meet all such requirements and are certified for marine use.
In multi-storey/underground car parks, ventilation is a safety issue. Our system of fire gas fans meets both the market’s requirements for CO control and the requirements for evacuation of dangerous smoke gases in the event of fire, as well as delivering energy savings of up to 80 percent in green ventilation mode.
Hospitals are demanding environments in terms of purity and temperature of the air. A correctly designed ventilation system, combined with our products and solutions, creates an optimal indoor climate. Cleanliness requirements are satisfied via hygiene- certified units and effective filters.
Effective ventilation is a safety issue both during the construction phase in a tunnel project and when the tunnel is in operation. Systemair’s tunnel fans ensure both good quality of air and smoke evacuation. Our products meet all fire safety requirements and, being made from stainless steel, are easy to maintain.
4 systemair
systemair
5
Selection tools making your work easier Systemair provides a range of powerful selection tools to help you quickly find the right product to meet your specific requirements. Find them at www.systemair.com.
The selection software SystemairCAD, is always updated with the newest features in Geniox and Topvex. Best functionality on the market, wrapped in an easy to use interface.
Our website provides detailed information about our products. It’s easy to determine a product’s performance at a specific operating point. Systemair contains product information in both print and digital form.
6 systemair
The 3-D models from SystemairCAD can easily be exported to other CAD software. SystemairCAD has plug-ins for the CAD software MagiCAD for AutoCAD and Revit. The plug-ins make it possible to insert Systemair air handling units directly into MagiCAD, AutoCAD, and Revit. SystemairCAD can also export DXF files (2D or 3D) and DMR files of a 3D CAD model to Autodesk Revit via an import plug-in.
systemair
7
Fans
The key to keeping air fresh
Systemair has a wide range of fans for use in various applications from residential buildings to small office premises to hospitals and large industrial applications. All products in our range have been extensively tested, both in the laboratory and in the field, in order to comply with current and future demands for low energy consumption. All products are also manufactured to comply with international environmental requirements.
Thorough testing ensures high-quality performance Our customers can rest assured that every fan that leaves our factories has been thoroughly tested. The AMCA-certified development center in Sweden, has one of the most modern testing and inspection facilities in Europe. The “quiet room” is a reverberation room with a background noise level of less than 10 dB(A). When measuring diffusers, a green laser light is used to show how the air from wall or ceiling mounted diffusers is distributed in the room. Furthermore, the climate chamber (down to -20 °C) is used all year round to test heat recovery units. On top of doing our own tests, we also work closely with respected testing institutes, universities and other external experts in the field of ventilation and air conditioning.
8 systemair
systemair
9
Air flows up to 30,000 m3/h
Air flows up to 60,000 m3/h
Air flows up to 60,000 m3/h Temperatures up to 200°C
Circular and rectangular duct fans
Roof fans
High temperature fans
A proud tradition of quality and innovation
Our classics
For kitchens and heavy-duty
Robust and durable, Systemair roof fans are available in horizontal or vertical discharge models that provide highly reliable exhaust solutions. Low-noise, explosionproof and smoke-extraction variants are also available, as well as thermo fans with the motor outside the airstream. With “Our roof fans with EC motors ensures low operational costs, as its motor saves energy and reduces carbon dioxide emissions.
Systemair igh temperature fans are the first choice for high air flow temperatures and harsh operating conditions. They are the smart choice when expectations are higher than average, in applications such as extraction from kitchens, process air systems and industrial ovens. Depending on the model, they are suitable for continuous air flow temperatures of up to 200°C.
The Systemair circular duct fan was the first of its kind, revolutionizing the world of ventilation when it was first unveiled in 1974. As the result of continuous improvements, our circular and rectangular duct fans set today’s standards in terms of performance, functionality and reliability.
10 systemair
Our circular and rectangular duct fans are used in offices, industrial and residential buildings where there is a need for compact and reliable air supply and extraction systems.
systemair
11
Air flows up to 8,000 m3/h
Air flows up to 190,000 m3/h
Explosion-proof fans
Plastic fans
The safest choice in ventilation
The smart choice for dirty or corrosive environments
The design and manufacturing of explosion-proof fans is one of Systemair’s specialties. Our EX portfolio is the most extensive on the market, fulfilling the highest expectations when it comes to ventilating any area where there is a risk of explosion, such as labs that handle chemicals and industrial facilities that generate combustible dust. Our EX fans are also ideal for ensuring high-safety ventilation solutions in the shipping industry.
Where dirt, corrosive gases or other problematic elements occur, fans are exposed to particular challenges. Our plastic fans were specially developed for such applications in the food, electronics and chemical industries. With the help of solid and carefully selected components, plastic fans function reliably in unfavorable conditions and have an impressively long service life.
Each of our EX fan models has been designed from scratch to ensure spark-free operation both electrically and mechanically, and we have a long tradition of relying on third-party testing to confirm full compliance with all relevant regulations, including ATEX Directive 2014/35/EC. The complete EX range meets the requirements for ignition protection type EX e “increased safety” or EX d “flameproof enclosure.” The EX fan portfolio is complemented by a range of suitable accessories that are also fully approved for the EX zone.
Choren Industries, Dresden, Germany Choren Industries is one of the leading suppliers of gasification technologies for solid biomass and carbonaceous residues. Their Beta facility, built in 2007, was the first commercial production facility in the world dedicated to synthetic biofuel. Our contribution: In this unique project, the complete range of Systemair’s explosion proof fans was installed in the production facility’s compressor hall.
Experimenta in Heilbronn, Germany Experimenta, a learning and sensory center, makes science and technology understandable and accessible in four elaborately staged theme worlds. Our contribution: Systemair supplied fans and ventilation units for a variety of diverse applications, including four PRF plastic fans that are used to ventilate the chemistry labs in the Energy and Environment theme zone.
12 systemair
systemair
13
Air flows up to 210,000 m3/h. 300°C/120 min.
Air flows up to 500,000 m3/h
400°C/120 min. 600°C/120 min.
Axial fans
Smoke extraction fans & pressure differential systems
The best in the business
Customized solutions for your safety No matter how varied your requirements are, the axial fan range at Systemair is certain to meet them. Our axial fans are well suited to a wide range of applications, encompassing everything from large shopping malls to underground car parks to tunnel and metro projects around the world. Safety applications such as smoke extraction and explosion-proof fans are also part of our core competencies. The AW sileo and AR sileo ranges are suitable for low pressure environments, while the AXC range is intended for medium to high pressure, making it ideal for industrial applications. Our large range of accessories make it easy to tailor individualized solutions.
Modern fire safety ventilation is based on a system approach that integrates smoke extraction fans with pressure differential. At Systemair, we have become increasingly involved in the engineering process for larger projects to design customized solutions that offer high levels of both safety and energy efficiency.
in combination with smoke extraction fans, the system effectively pushes smoke toward them so that they can quickly and efficiently remove it from the building. Our unmatched range of smoke extraction fans have all been tested according to the European product and testing standard EN 12101-3.
Our pressure differential systems pump in fresh air and over-pressurize so that no smoke can enter. When used
Bolshoi Ice Palace, Sochi, Russia The Bolshoi Ice Palace was constructed for use as a hockey stadium during the Olympic Games in 2014 and is located in the Olympic Park near the sea. Designed for 12,000 visitors, the building’s architecture was inspired by the famous Fabergé egg, its concept based on the image of frozen droplets. Our contribution: The arena is equipped with 75 Systemair AXC fans for smoke pressurization. TA units and duct fans are used to supply and extract air. Completion date of construction was 2012. Total building area is approximately 55,000 square meters.
14 systemair
systemair
15
Air flows up to 540,000 m3/h Pressure up to 5000 Pa Thrust up to 2,500 N Temperature up to 400°C/120 min.
Metro & Rail Tunnel (MRT) and road tunnel ventilation Complete, high-performance systems Systemair has several decades of experience designing and manufacturing ventilation solutions for all types of road, rail and metro tunnels around the world. Our deep expertise and sophisticated calculation tools enable us to create customized solutions that provide a high level of safety and comfort while simultaneously minimizing energy consumption through the use of our specially designed motors, impellers and fan casings. Air volumes up to 150 m³/s and 5000 Pa are available.
traffic, the fans transport exhaust gases, dust and heat to the outside, ensuring a clear view and good travel and working conditions for both people and vehicles.
Our tunnel fans prove their worth right from the start of the construction phase of the tunnel project by supplying the site with fresh air. When the tunnel is opened to
Our research and development center in Germany plays a key role in continuously advancing our world-leading expertise in this area.
In the event of fire, our tunnel smoke extraction fans save lives by effectively keeping escape and rescue routes free of smoke and heat. They are tested in accordance with EN 12101-3 for temperatures up to 400°C for 120 minutes.
E39 Byfjord and Mastrafjord tunnels in Norway The Byfjord and Mastrafjord tunnels are located in southwestern Norway between high mountains and deep fjords on the E39 highway between Trondheim, Norway, and Ålborg, Denmark. When it was opened in 1992, the Byfjordtunnel was the world’s longest undersea tunnel at 5875 meters long, its lowest point 223 meters below sea level. The Mastrafjord tunnel is slightly smaller at 4424 meters long and 133 meters below sea level. After twenty years of use, a full refurbishment of the tunnels’ safety equipment was required.
16 systemair
Our contribution: Systemair delivered a tailored solution comprised of 88 MoJet AJ1120 fans with 37 kW IE3 motors (stainless steel execution), 88 mounting frames made from stainless steel, 88 specially made isolator switches and 88 automatic lubrication systems. The customer chose our solution because we were able to prove that it offered the lowest total cost of ownership (TCO), considering not only the cost of the initial investment and installation, but also annual operation and maintenance costs over a 30 year period. The total order value was 2 million euros.
systemair
17
Thrust 10 – 85 N
Car park jet fans & control systems Custom designed, integrated solutions Our car park jet fans ensure good air quality and maximize fire safety by efficiently removing car exhaust, dust and smoke from underground parking garages. On top of delivering high-quality fans, we also supply main exhaust/supply fans and control sytems, and use our engineering expertise to help customers create a tailored solution and integrate it into their project. During the planning phase, we offer Computational Fluid Dynamics (CFD) simulations to prove that the proposed system design will operate efficiently. Systemair jet fans are tested in accordance with EN 12101-3 and correspond to the temperature class F300–300°C/120 min, and F400–400°C/120 min.
Römer in Frankfurt am Main, Germany The Römer has served as Frankfurt’s city hall for more than 600 years and is one of the city’s most important landmarks. As part of the structural restoration of the car park below the building, the customer needed a new solution for ventilation and for smoke extraction in the case of fire.
The Systemair control system encompasses the fan control for ventilation and smoke extraction in underground car parks.
18 systemair
Our contribution: Systemair provided a Computational Fluid Dynamics (CFD) analysis to simulate the air flows within the two-storey car park, after first virtually dividing it into six areas due to its architectural complexity. Based on the results of the CFD simulation, 54 Systemair jet fans were installed in the car park, primarily type AJ8 400-2/4 complemented with a smaller number of type AXC 630-9 for supply and exhaust air. All of the fans are equipped with a frequency converter to guarantee minimal energy consumption, low noise performance and material protection.
systemair
19
Air handling units
Air treatment at its best
Systemair’s extensive range of air handling units (AHUs) regulate and circulate air in heating, ventilating and air-conditioning systems. Ventilation accounts for a considerable share of energy consumption, in the form of heating and energy losses as heated air is replaced by cold air. Energy efficient products with energy recovery capabilities are becoming increasingly important in reducing energy consumption and, at the same time, creating a healthy indoor climate. Our range of AHUs includes modular air handling units and compact air handling units, as well as a range of products specially designed for use in residential ventilation applications. We also offer a complementary range of air distribution products, fire dampers, air cooled and water cooled chillers, close control air conditioning, air conditioning water terminals, rooftop air conditioners, water source heat pumps, air curtains, fan heaters and radiant heaters.
20 systemair
systemair
21
Air flows up to 130,000 m3/h.
Modular air handling units
Full connectivity and control
Ultimate in flexibility
Access - the control system for Systemair modular and compact air handling units
In Systemair we focus on developing energy-efficient air handling units with state of the art technology. Continuous research and development ensure an energy-efficient flexible air handling unit, both in terms of design and function, and with focus on being a unit that is easy to install and use. With a modular air handling unit you have the option of configuring for many different applications. The flexibility of the modular unit makes it possible to optimize the air handling unit for any given project. The modular air handling unit is available in the range 0,2-24 m3/s (750-86.999m3/h). The units can be constructed as an indoor or an outdoor air handling unit. All units can be produced with fully integrated controls if needed. The modular air handling unit is dimensioned in the design program SystemairCAD. SystemairCAD makes it possible to combine air handling unit functions as required very quickly and easy.
Full control
SYSTEMAIR
ACCESS
NaviPad puts you in control of
Home button
the status of your air handling
Gives you a visual indication of the status
unit – at all times. Should an
for each connected air handling unit.
error occur you will immediately be notified by an alarm. Press the alarm icon to view the list of active alarms including
Starting page
the alarm history.
Important operating data are shown in real time, easy to change with a few clicks.
Skåne University Hospital (UMAS), Malmö, Sweden SYSTEMAIR
UMAS is one of the leading hospitals for infectious diseases in the world. The building of its new emergency and infectious diseases unit – designed by Aarhus-based Danish architecture firm C.F. Möller A/S – represents its largest investment ever, of more than 125 million euros. Our contribution: Systemair delivered 18 air handling units in sizes DV 40 to DV 150 together with other products including duct fans, roof fans and smoke exhaust fans for use in the ventilation systems designed by Incoord AB, Stockholm.
ACCESS
Full control You have access to all operating data in real time. Should an error occur you will immediately be notified by an alarm. Press
Plug’n’play with Geniox & Topvex NaviPad comes as standard with Systemair’s Geniox
the alarm icon to view the list of active alarms including the alarm history.
and Topvex air handling units.
SYSTEMAIR
ACCESS A complete control solution for air handling units, making advanced technology easily accessible – helping you to create the perfect indoor climate.
22 systemair
systemair
23
ATEX air handling units
Marine, Oil & Gas applications
The ultimate in safety
Complete HVAC solutions
Our explosion-proof FL ATEX series air handling units are designed to meet the requirements of industrial environments where there is a risk that gases, vapors, mists or dusts could combine and ignite under certain operating conditions. They are widely used by companies that produce chemicals, pharmaceuticals, cosmetics and food, as well as in refineries off-shore platforms and waste recycling facilities.
All HVAC system components and air handling units operating in environments where there is a risk of explosion must be specially designed for the task. FL ATEX series AHUs are tailored to meet the latest international norms and directives regarding ATEX, including 2014/34/EU. We also offer a comprehensive range of EX fans and accessories that are fully approved for use in EX zones.
Systemair offers a wide range of robust and reliable ventilation, air-conditioning and heating products ideally suited to marine and oil & gas applications, where space restrictions and widely varying weather conditions can present significant challenges. Whether it is air conditioning of cabins on a cruise liner, cargo hold ventilation on a freighter or exhaust air in the engine room of a ferry, our wide product portfolio always ensures the right solution. Where applicable, we can deliver our products in accordance with the standards of classification societies such as Germanischer Lloyd, Det Norske Veritas, Lloyd’s Register of Shipping, Russian Register, American Bureau of Shipping, Bureau Veritas and RINA. These certificates are backed by 40 years of experience and our expert knowledge in comfort and safety ventilation.
24 systemair
systemair
25
Hygiene certified air handling units
Healthcare applications
The highest possible hygiene performance
Faster recovery with fresh air
Systemair can offer for strictly clean applications like heath care, clean room and pharmaceutical plants hygiene air handling units tested and certified according relevant European standards (e.g. VDI 6022-1 and DIN 1946-4). Certification of this hygiene application is carried out by an independent institute. The standard and guidelines define the specific requirements for a hygienic version of an air handling unit to the smallest detail, from design of the unit until assembly, shipment and maintenance.
26 systemair
Special care is taken on the inner surface materials, arrangements of fans, accessibility of the unit sections, proper drainage of condensate water, seals and gaskets to avoid bacterial growth. Systemair completes it with additional instructions relating to proper use, cleaning and maintaining for a durable and save installation.
Establishing an optimal indoor climate in hospital buildings has been proven to play a key role in reducing patients’ recovery time. Hospitals and other healthcare facilities require reliable, energy-efficient ventilation solutions that take into account the fact that many patients are very ill, have weakened immune systems and/or spend a great deal of their time sitting or lying still. A higher level of air circulation is necessary to meet stringent hygiene requirements that help to prevent the risk of spreading antibiotic-resistant bacteria and other contagious infections. Further, experience has taught us that healthcare facilities benefit significantly from imple-
menting ventilation solutions that provide a high degree of central control, so that staff can focus their attention on caring for patients. Our wide range for healthcare applications includes: • Air handling units in hygienic design • All types of fans for air extraction • Chillers and heat pumps • Air distribution products • Electrical heaters • Accessories
systemair
27
Compact air handling units
Air flows up to 15,000 m3/h.
Set up – connect – enjoy! AHU No 12.01.001 Range: TOPVEX
Our compact air handling units save both energy and time. They are delivered ready to install and connect, which ensures easy commissioning. All components, such as fans, filters, heat exchangers and heating batteries, as well as control and regulator units, are integrated and coordinated with each other.
In this way, you obtain a healthy and pleasant indoor climate in offices, schools, hotels and many other buildings. Thanks to modern motor technology, these compact air handling units are extremely energy efficient.
Shopping & entertainment center in Murmansk, Russia
Systemair ACCESS is a complete control solution developed by Systemair for Topvex & Geniox. See page 23.
28 systemair
Murmansk Mall is the largest shopping and entertainment center located within the Arctic Polar Circle region. Its 65,000 square meter area includes shops, offices, cinemas, restaurants and a large parking garage. It was a challenging project due to harsh conditions including winter temperatures that drop as low as -42ºC and an aggressive marine climate that places special demands on the quality of the equipment.
provide high-quality ventilation and ensure a comfortable indoor climate. Thermal fans are used to ventilate the restaurant zone, and Frico air curtains protect the entrance of the building and minimize heat losses. Our solution also includes corrosionresistant aluzinc (AZ185) covers on the DV air handling units and sheet steel coated with aluzinc (AZ185) that provide corrosion resistance equivalent to class C4 as per EN ISO 12944-
Our contribution: Systemair delivered an efficient and reliable solution consisting of air handling units and duct fans that
2. The total project value was just over one million euros.
systemair
29
Award-winning air handling in challenging environments Menerga Adconair AdiabaticzeroGWP Menerga‘s carbon-neutral cooling technology – based on hybrid, evaporative cooling – has been awarded 1st prize in the German Cooling Award 2018 in the category
Menerga Adcoolair for Data Centres Compact cooling units for data centres with evaporative cooling and outdoor air pre-cooling from Menerga have been awarded 3rd prize in the German Data Centre Award 2018 in the category „Data Centre Air Handling and Cooling“.
Menerga develops and produces innovative ventilation and air conditioning systems for extensive fields of application since 1980. The Menerga name is based on a simple guiding philosophy: “Creating a good indoor climate – through Minimal ENERGy Application”. Menerga air conditioning systems are individually designed to meet each project’s specific requirements from hygiene to industry, precision, data center, air handling and swimming pool hall dehumidification.
30 systemair
„Energy-Efficient Cooling- and Air-Handling Systems with Indirect Cooling“.
Data Centre
Precision
Industry
Pool
Hygiene
Information and communication technology is a high priority in everyday life. Technological developments such as cloud computing or large data, as well as the increasing spread of mobile devices, have led to very high requirements regarding computer performance. Therefore it is of utmost importance to keep the growing data centre capacities and the resulting energy requirements and CO2 emissions as low as possible with the help of an efficient cooling system.
Museums, historic buildings as well as measuring rooms require precise air-conditioning. In areas where high fail safe, reliability and efficiency are required, we can precisely control the temperatures and the relative humidity with our highly efficient systems and an intelligent control system. This ensures that there is always a precise air conditioning customized to the applications’ requirements.
In manufacturing, it is important not only to air-condition the processes and products, but also to create a good indoor climate for the employyees, one which is in line with all regulations. The requirements of such productions are very high and specific. Customized air conditioning not only increases employee motivation and performance, but also has a positive impact on the production quality and resilience of the production machines.
The air conditioning of swimming pool halls is one of the most demanding tasks of air conditioning and in that area we have our origin. On top of creating an ideal feel-good climate for athletes and spa enthusiasts, we also strive to protect your building from moisture damage by continuously dehumidifying the swimming pool air. And we set our sights not only on the swimming pool hall itself: with our systems you also create the ideal climate in neighbouring areas such as restaurants, sports areas or changing rooms.
Hygiene is in the focus of healthcare, as contamination by germs, bacteria or viruses should always be avoided. In particular areas of protection such as the operating area, dynamic shielding by ventilation is also required in addition to working medical standards. All these requirements are met with a high degree of resilience, as well as by keeping operating costs as low as possible, since we always focus the on the overall cost-effectiveness of your system.
Research project ALMA, Atacama desert, Chile: 60 telescopes at an altitude of 5.100 m. Extreme operating conditions and precise research requirements are possible with Menerga solutions. Photo: ESO/José Francisco Salgado. systemair
31
Roof-Line units
Data Centre applications
Solution for decentralized ventilation
Cooling the ones and zeros
Systemair offers a comprehensive range of products for ventilation and cooling for data centres from concept to completion – even in the most challenging climatic regions.
Weatherproof roof units with an integrated heat recovery system and air flow range up to 13.000 m3/h are especially suitable for ventilation of exhibition halls, industrial halls, storage halls, sports halls and other multipurpose halls with hights up to 30 m, where the air supply and exhaust from the high ceiling is acceptable. Especially designed light weight housing made of salt water resistant aluminum (AlMg3) enables quick and easy installation on the roof of the building without the need for additional ventilation duct system. Wall panels are thermally insulated with 50 mm of rockwool. The unit consists of an external part (DWR) where the heat exchanger, high-efficiency EC plug fans and air filters are located and the internal part (DD) with integrated heating and cooling batteries as well as supply and exhaust air distribution elements. All the components are controlled with an integrated controller.
32 systemair
Since cooling represents the biggest slice of the total cost in a data centre there is an increased need for energy-efficient cooling of the IT equipment. And lower energy demands lead to a reduction of the carbon footprint of the units.
Each data centre project requires its own carefully tailored solution comprised of the following components: • Air handling units • Water- or Air-cooled chillers • Close control units • Fans or fan-walls • Air distribution products and spot cooling • Heat exchangers • Heat pumps • Condensing equipment • ATEX and fire safety ventilation
Close Control units Systemair offers a wide range of Close Control units that fit practically every Data Centre design. Direct expansion and chilled water SysTemp units are characterized with low sound levels and energy efficiency. Free-Cooling units Direct Free Cooling unit (DFC) is able to use 100% cooling energy of Fresh air and has smallest pressure drop that results in smallest pPUE figures. Indirect Free Cooling unit (IFC) is safest solution even for extreme climatic zones where outdoor air relative humidity level can vary a lot. Unit uses outdoor air adiabatic cooling to obtain a low OPEX and pPUE.
systemair
33
Integrated solutions Ventilation & air conditioning in one system
With the help of SystemairCAD, it’s easy to design a solution that combines one or more air handling units with a chiller or heat pump to create a fully integrated ventilation and air-conditioning system. More information about SystemairCAD is available on page 7.
SystemairCAD calculates AHU’s in combination with a chiller or heat pump
When two air handling units (AHUs) are connected, the components ensure optimal output performance of the chiller or heat pump. The diagram below includes an extra buffer tank, which we recommend when several units are connected, in order to reduce the number of starts and stops for the compressor.
+
+
Example installation of one AHU master, one AHU slave and one SysAqua chiller/heat pump
34 systemair
systemair
35
Air conditioning
Smart cooling solutions for human comfort and industrial processes
Systemair’s air conditioning products are suitable for a wide variety of applications such as offices, shopping centers, schools, hotels, public transports and residential buildings, as well as industrial applications. To offer our customers not only a product but a complete solution, our extensive range includes everything from air-cooled and water-cooled chillers and heat pumps to rooftop units, water source heat pumps, water terminals, close control units and direct expansion units. We also produce products for the future, such as rooftop solutions with high performance heat recovery systems and standalone DX air conditioners for heating and cooling (VRF).
36 systemair
systemair
37
Hydronic systems Ultimate comfort and high efficiency Our hydronic system uses water as the exchange fluid, offering the perfect combination of comfort and high efficiency. Appropriate for any type of building, the system consists of an air or water cooled chiller or heat pump that provides cold or hot water to water terminals. It can be complemented with air handling units to ensure perfect air quality. This system is particularly well suited for applications such as hotels, shopping centers, hospitals and office buildings. The air cooled chiller variant of the system is also a fundamental part of many industrial processes.
R410A Scroll Cooling 5 - 897 kW Heating 6 - 902 kW R134A / R513A Screw Cooling 295 - 1395 kW
Air cooled chiller, heat pump and condensing unit with scroll compressor
R134A Screw Cooling 444-1567
Water cooled chiller, heat pump and condensing unit with scroll compressor
Water cooled chiller, heat pump, condensing unit with screw compressor
Enter the Era of connected units and make significant savings !
Offering more than reliable products is the Systemair’s aim. From that perspective, we created ACloud. With this new software, you will get the control of all your chillers and heat pumps at anytime and from anywhere. And it will help you to decrease your energy consumption and optimize your maintenance interventions !
Shopping center in Osijek, Croatia
Sysoft AC The online selection software for all your Air Conditioning projects
www.sysoftac.com 38 systemair
Air cooled chiller and heat pump with screw compressor
Free-cooling module
Osijek is the fourth largest city in Croatia with a population of more than 100,000. When one of its major shopping centers required a combined ventilation and air conditioning system, the owner of the building turned to Systemair. Our contribution: Systemair designed a highly efficient solution comprised of AHUs, fans, water terminals and a total of four air cooled chillers, with a total capacity of 450 kW.
systemair
39
Water terminals, Water source heat pumps and Roof top units The cornerstones of comprehensive air conditioning solutions
Ducted
Cassette Heating 0,4 - 25 kW Cooling 0,5 - 25 kW
Floor/Ceiling
High wall
Roof Top
Water Source Heat Pump
New airport in Istanbul - Turkey The new airport in Istanbul is the largest infrastructure project in Turkey. When completed, it will become the largest newly constructed airport in the world.
Heating 34 – 214 kW Cooling 23 – 219 kW
40 systemair
Heating 2,4 – 38 kW Cooling 2,0 – 30 kW
Our contribution: Systemair has been chosen as a supplier thanks to its efficiency, quality and the design of its products, the high quality standards of its international production and overall trust in the brand. 531 air handling units and more than 5,000 water terminals will be installed in the airport.
systemair
41
42
Air distribution products
The perfect fusion of function and form
Systemair develops, produces and delivers air distribution products, diffusers and air flow control units for private and commercial buildings. These components not only comply with the interior design requirements, but also make their own contribution to a pleasant indoor climate. This is guaranteed by our development lab, which is one of the most modern in Europe. There we measure air volumes, throw, coanda effect, sound level and temperature sequences so we can provide our customers with accurate data.
Aupark shopping center in Kosice, Slovakia Aupark, located in the center of Kosice, is one of the biggest shopping malls in Slovakia with an area of 34,000 square meters. It has 140 retail stores and 1,100 parking spaces. Our contribution: Systemair supplied an assortment of duct, roof and axial fans, as well as air curtains, air distribution products and fire dampers for a total value of 650 000 euros.
42 systemair
systemair
43
Diffusers, grilles and air flow control
Select with Systemair DESIGN
Robust and discrete
Easy but precise
Systemair’s range includes a wide selection of air terminal devices for all possible environments and positions.
The new online tool Systemair DESIGN helps you find suitable air distribution products, fire or smoke dampers in a very easy, but precise way.
The dampers and control equipment for protection against smoke and fire are certified for use during normal operation and in the event of a fire.
44 systemair
Technical data and information is displayed at a glance with direct access into MagiCloud database full of BIM models. Indoor air quality and draft risk is assessed on a room level in 3D view.
Smooth product configuration ensures that you will never forget to include all the required accessories as well.
systemair
45
Fire and smoke dampers Key components of fire safety ventilation Systemair fire and smoke control dampers are used to minimize the property damage, help with evacuation of occupants and most importantly prevent loss of life by fire or smoke. When penetrating compartments by the duct-work of the heating, ventilation, and air conditioning system, the integrity of fire rated walls is sustained by the use of fire and smoke control dampers.
Systemair fire and smoke control dampers are known for their lightweight design, high-quality and energyefficient free area. All Systemair fire and smoke control dampers are CE certified. They can be supplied with a manual actuator, optional accessories, e.g. micro-switches, electromagnets or a servo-driven actuator and communication control units, as standard.
VM-Mountain, Copenhagen, Denmark VM-Mountain is one of the world’s most advanced buildings and the winner of four major international architecture awards. Bjarke Ingels, one of Denmark’s most promising architecture talents, was commissioned to design a non-conventional building in Copenhagen with an integrated, multi-storey car park.
Example of a complete fire damper controls system
46 systemair
Our contribution: Systemair supplied VM-mountain with MUB fans complete with a control system and all necessary accessories, as well as WVA smoke extraction units and our K range of duct fans.
He designed a building where the facades face in different directions and apartments are arranged in the shape of mountain terraces, with the required multi-storey car park underneath. All apartments have unobstructed views with terraces and small gardens.
systemair
47
Residential ventilation Top-quality air and great indoor climate
Systemair’s line of heat recovery ventilation units is ideal for homes, small offices and similar premises. They offer a high level of comfort both in terms of heating and clean air supply, along with significant energy savings. All units are operated via a modern control system that makes it easy to check their status at any time. Further, our sleek and discreet range of controls, supply grilles, exhaust grilles and other accessories blends in perfectly wherever they are installed. The rotary or counter flow heat exchangers in every product ensure high operational efficiency in all conditions, fulfilling markets demands for low energy consumption and sound levels. State-of-the-art EC technology contributes to both to energy efficiency and a low Specific Fan Power (SFP) factor, enabling us to meet ErP requirements. Technical performance is certified by the independent certification program Eurovent.
48 systemair
Keep control of your climate back home with unique touch display and smartphone feel
More convenience, less energy consumption If your ventilation unit is the heart pumping fresh, healthy air into your home, your control system is the brain. And the cleverest in its class is Systemair’s control system with the unique touch display. This gives you and your family the best possible indoor air in all situations, while also helping you saving energy. SAVE units are controlled by a modern touch display mounted on the ventilation unit. And of course, you can fit it to the wall in your hallway. The display is every bit as attractive, effective and easy to use as your smartphone.
systemair
49
Heating products
Warm and cozy with minimal energy loss
Systemair’s heating range consists of air curtains, fan heaters and radiant heaters, which are all designed to ensure that heat is exploited optimally with minimal energy loss. Our air curtains provide the most efficient separation with the lowest possible energy consumption, regardless of whether it is the heat or cold that you want to keep inside. Our radiant heaters imitate the sun, only emitting heat when the rays hit a surface, so that the room temperature can be lowered without its occupants becoming cold. Our fan heaters are reliable and the investment cost is low compared to other heating systems. One of their greatest advantages is the option of using these products to combine heating and ventilation.
Frico, that is a member of Systemair group, is the market leader in air curtains and heating products in Europe. Frico is represented via subsidiaries or distributors in 70 countries. The brand represents 80 years of accumulated experience in developing products that offer customers a comfortable indoor climate. Frico offers a comprehensive solution consisting of airborne products for heating and energy saving.
50 systemair
systemair
51
Air curtains The invisible door Air curtains create an invisible barrier in an open entry or passage areas, separating different temperature zones from each other without blocking the access of people or vehicles. They reduce energy loss and create a pleasant indoor climate. They are equally helpful in situations where you need to prevent the escape of cold air or entry of dust, exhaust gases or insects. Frico Thermozone technology has enabled us to develop a line of air curtains in which performance, sound level and the orientation of air flow are all fully optimized. We have a close cooperation with leading architects and product designers resulting in a modern and aesthetically pleasing design of our products. Our wide range includes systems with or without heating, suitable for openings in any area – from a passenger doorway to an aircraft hangar entrance. Frico was founded in 1932 and has been part of the Systemair Group since 1992, making us Europe’s leading manufacturer of air curtain systems, radiant heaters and fan heaters. The Frico brand is represented in 70 countries by our subsidiaries or distribution partners.
Deichman in Copenhagen, Denmark A Deichman shop in Copenhagen needed a solution to deal with the cold draughts and pressure loads caused by its location near the main entrance of a shopping mall. Our contribution: Two PA3520WL air curtains were installed at the shop’s four-meter wide doorway, which create an efficient air barrier thanks to Thermozone technology. The stylish product design ensures that the air curtains blend in with the shop’s decor.
52 systemair
systemair
53
Fan heaters Powerful and silent Fan heaters are used in a wide variety of applications including storage rooms, sport venues, shops, drying rooms, stables and boats. The investment for fan heaters is relatively low in comparison to other heating systems.
a wall. Nevertheless, they meet the highest expectations even under harsh conditions like corrosive or EX proof environments. They are available with electrical, hot-water or DX heating as well as cooling and are both quiet and powerful.
Our fan heaters are known for their extremely compact and light design. They are portable or easy to mount on
Tour en Fosse plant near Paris, France Tour en Fosse is a plant outside Paris where Métro de la RATP trains are repaired and serviced. As part of their work, employees are often in a pit under the trains with their heads only slightly above ground. The cold draught from outside was creating poor working conditions for them. Our contribution: The employees are now protected from the weather after the installation of two large UF600 air curtain units, which effectively separate indoor and outdoor air. In addition, the energy losses caused by the large doors have also been reduced.
54 systemair
systemair
55
Radiant heaters Heating naturally
Our radiant heaters imitate the sun – the heat only develops once the rays encounter a surface. The people present will be warmed before the air heats up. As such, the temperature can be lowered without compromising on comfort. Heat radiation systems make spot and surface heating possible. Large spaces can be divided into smaller areas and heated differently, depending on needs. According to this principle, even a single workspace can be heated. This means that energy is saved while increasing comfort. Thanks to their discreet design, our radiant heaters provide heat without being noticed. Easy to integrate in any context, they don’t cause any air movement and because they can be mounted in the ceiling, walls space is kept free.
Hotel Avalon in Gothenburg, Sweden
56 systemair
Hotel Avalon, located in the center of Gothenburg, is a four-star
Our contribution: Since a large part of the terrace is exposed,,
design hotel with 101 rooms. During the summer months they
compact and stylish IH infrared heaters have been installed
open their large outdoor terrace with seating for 180 guests.
along the walls to provide evening heat. They have high-
However, the Nordic climate have some chilly summer nights,
intensity halogen bulbs and polished reflectors that provide
so the hotel wanted to find an outdoor heating solution that
heat even in open areas.
would fit into its sleek and stylish environment.
systemair
57
58
Strong focus on Research & Development Systemair’s product developers focus unceasingly on improving the indoor climate for our customers, while developing products that require a minimum of energy to power them. Their work responds to impulses from the outside world, in the form of legal requirements, customer comments, new ideas from employees and the latest academic research. Systemair’s collaboration with the higher education sector enables us to work quickly with integrating new research discoveries into our operation.
project management tools, we work in integrated teams producing successful results. Systemair works systematically on standardizing its procedures to make it easier to share and take in research results and recently generated knowledge – whether originating in New Delhi in India, Kansas City in the USA or Skinnskatteberg in Sweden. Our business system is based on the methodology of ISO 9001 and 18 of our production facilities are also certified under this standard.
Systemair has today 23 development teams at 9 technology centers in 18 countries on three continents. We employ more than 230 engineers in product development all over the world, but with a common technology platform, shared database and the same processes and
The latest academic findings and customer comments are put to use in creating the products of the future. The development center in Skinnskatteberg is one of Europe’s most modern facilities for gauging air flow, sound levels, pressure and energy consumption.
58 systemair
Meeting rigorous environmental and energy-efficiency demands Precision testing In the final phase of product development, the product’s efficiency and effectivess is tested. These parameters are evaluated and documented in precise detail to provide customers with a decision-making basis that reflects real conditions. Through this process, Systemair can guarantee that all our quoted catalogue data is accurate. Precision testing is an important factor in Systemair’s success, because it represents an assurance to our customers that Systemair’s products truly keep their promises. Systemair operates test facilities that are accredited by the Air Movement and Control Association (AMCA).
An important driving force in the ventilation sector is the emergence of increasingly strict environmental classification systems, including BREEAM, LEED© and Miljöbyggnad (Environmental Building). A common factor among these systems is that they stipulate how much energy new buildings are permitted to consume. This often leads to higher-density building, which, in turn, makes the requirements for effective ventilation more important. The demands for low energy consumption are also creating a greater need for demand-led ventilation and integrated building management systems. Systemair is at the forefront of this trend, offering a wide range of products capable of meeting even the most rigorous environmental and energy-efficiency demands.
systemair
59
Global presence
Global presence
Systemair worldwide
3
50
Distribution centres
Countries with Systemair sales office
27 Production facilities
Always close to you!
I 61
62 systemair
systemair
63
www.systemair.com
Systemair AB • November 2018 • E8289