Elektrim Metric IEC AC Explosion Proof Motors ATEX Certified Protection for Export Hazardous Environment Applications 5.5-220 HP 3PH TEFC 50 Hz NEMA AC Foot Mounted and D-Flange Motors Features
• ATEX Certified • Inverter Duty Rated • VPI Process Applied • Protection Degree: IP55 • Enclosure: TEFC F3 Rigid Cast Iron Frame • Warranty: 3-Years • Duty S1 • Voltage 400V +/- 5% • Class “F” Insulation
• Ambient Temperature from 20ºC to +40ºC (Class T5) • Increased safety of Terminal Box • Terminal Box with 1 Cable Inlet • Cable Inlet Ant. Terminals adapted for cable with copper wires • 3 Terminals for direct on-line starting • According to standards: PN-EN 60034-1, PN-EN 60079-0, PN-EN 60079-1, PN-EN 60079-7
• Classified to category 2G acc. to Directive 94/9/WE (ATEX)
Applications Designed for the hazardous applications found in the petroleum, natural gas, chemical and industrial paint industries where explosive mixtures of combustible gas, vapor or dust, classified as Group II, Temperature Class T5 or lower, may exist. Motors can be operated in Zone 1 & 2.
www.elektrimmotors.com or call 855-Go-Elektrim
ISO 9001
Operating Parameters
FRAME
Rated Output
RPM
PN
Efficiency
Data of Rated Output Power AMPS Factor PF lN
kW
HP
nN min-1
ナ起 %
160M2A 160M2B 160L2 180M2 200L2A 200L2B 225M2 250M2 280S2 280M2 315S2 315M2A 315M2B
11 15 18.5 22 30 37 45 55 75 90 110 132 160
15 20 25 30 40 50 60 75 100 125 150 180 220
2925 2920 2925 2945 2960 2960 2968 2970 2977 2970 2977 2975 2975
88.5 89.5 91.3 91.5 92.9 93.7 94.5 93.5 94.0 94.7 95.1 95.0 95.4
0.89 0.91 0.90 0.89 0.89 0.89 0.89 0.90 0.90 0.91 0.91 0.91 0.89
160M4 160L4 180M4 180L4 200L4 225S4 225M4 250M4 280S4 280M4 315S4 315M4A 315M4B
11 15 18.5 22 30 37 45 55 75 90 110 132 160
15 20 25 30 40 50 60 75 100 125 150 180 220
1463 1460 1465 1465 1472 1475 1480 1483 1485 1485 1480 1487 1483
89.5 89.8 90.8 91.5 92.5 92.6 94.0 93.5 94.2 94.8 94.2 94.9 95.5
0.84 0.86 0.90 0.90 0.88 0.88 0.88 0.91 0.90 0.91 0.92 0.90 0.90
160M6 160L6 180L6 200L6A 200L6B 225M6 250M6 280S6 280M6 315S6 315M6A 315M6B
7.5 11 15 18.5 22 30 37 45 55 75 90 110
10 15 20 25 30 40 50 60 75 100 125 150
962 960 973 980 981 982 985 985 985 985 984 985
87.5 88.2 89.0 90.5 90.5 91.9 92.5 93.0 93.5 93.5 93.7 94.2
0.81 0.82 0.85 0.86 0.88 0.88 0.89 0.87 0.89 0.89 0.88 0.89
160M8A 160M8B 160L8 180L8 200L8 225S8 225M8 250M8 280S8 280M8 315S8 315M8A 315M8B
4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90
5.5 7.5 10 15 20 25 30 40 50 60 75 100 125
710 705 708 730 733 735 735 738 737 737 735 737 737
81.0 82.5 83.5 88.5 89.5 89.5 90.4 91.5 92.8 92.5 92.7 93.2 93.2
0.75 0.75 0.78 0.76 0.83 0.81 0.80 0.84 0.83 0.84 0.81 0.82 0.82
-
Ratio of Torque
TN [A] 400V Nm 2p = 2 3000 RPM 20.2 36 26.6 49 32.5 60 39 71 52 97 64 119 77 145 94 177 128 241 151 289 183 353 220 424 272 514 2p = 4 1500 RPM 21.1 72 28 98 32.5 121 38.6 143 53 195 66 240 79 290 93 354 128 482 151 579 183 710 223 848 269 1029 2p = 6 1000 RPM 15.3 74 22 109 28.6 147 34.5 180 40 214 54 292 65 359 80 436 95 533 130 727 158 873 189 1066 2p = 8 750 RPM 9.5 54 12.8 75 16.6 101 23.6 144 29.1 195 37 240 44 286 56 388 69 479 84 583 106 715 142 972 170 1166
Moment of Inertia J
Weight IM B3 M
kgm2
kg
5.7 6.0 6.5 6.8 6.0 6.7 7.0 6.9 7.5 7.0 8.3 8.5 9.1
0.04 0.05 0.06 0.07 0.15 0.18 0.26 0.36 0.76 0.87 0.91 0.98 1.20
150 158 176 210 285 315 375 434 580 620 755 795 855
2.9 3.2 2.9 2.9 2.5 2.2 2.3 2.6 2.5 2.6 2.2 2.5 2.6
7.5 7.9 6.9 7.2 7.1 6.3 7.0 7.3 7.3 7.3 6.9 7.6 8.0
0.06 0.08 0.11 0.13 0.31 0.44 0.53 0.79 1.37 1.63 1.67 1.84 2.27
150 172 205 225 310 350 390 465 630 670 785 825 865
2.2 2.2 2.4 2.5 2.4 2.1 2.6 2.0 2.2 2.3 2.5 2.3
3.0 2.8 2.4 2.4 2.2 2.2 2.3 2.3 2.2 2.2 2.0 2.1
6.4 6.7 5.6 6.8 6.9 6.3 6.8 6.5 6.2 6.6 6.8 7.2
0.07 0.10 0.19 0.41 0.47 0.76 1.23 1.35 1.61 2.16 2.29 2.86
146 173 210 290 305 365 458 555 600 785 815 900
2.1 2.5 2.7 1.9 2.2 2.0 2.0 2.5 2.0 2.1 2.0 2.5 2.4
2.7 3.1 3.0 2.5 2.1 2.0 1.8 2.1 1.8 2.0 1.9 1.9 1.9
5.1 5.5 5.7 5.5 5.5 5.6 5.2 6.3 5.3 5.4 5.3 6.2 6.5
0.06 0.08 0.10 0.19 0.45 0.58 0.68 1.27 1.47 1.80 2.16 2.29 2.86
132 142 162 208 290 320 350 455 575 635 785 810 890
LRT
BDT
LRA
TL/TN -
Tb/TN -
lL/lN -
2.1 2.1 2.4 2.7 1.9 2.2 2.4 2.0 2.1 2.0 2.2 2.1 2.3
2.5 2.2 2.8 2.6 2.3 2.5 2.5 2.0 3.3 3.2 3.3 2.8 2.5
2.5 2.5 2.3 2.5 2.9 2.1 2.4 2.4 2.5 2.6 2.3 2.3 2.7
All Data Subject to Change Without Notice.. Elektrim Metric IEC Explosion Proof motors available upon special order only. Minimum quantities apply. Call Elektrim at 1-855-Go-Elektrim or 1-855-463-5358 for more information.
Extended Technical Information and Additional Options Symbols of Offered Motors MOTOR TYPE
160
EcS/L,K/g-EP
-
EcS/L,K/gb-EP
II 2G Exde IIB T5
cS/L,K/gb-EP
II 2G Exd IIB T5
FRAME OF MOTOR & MARKING 200 225 250 Motor with Flame-Proof Enclosure & with increased safety Terminal Box II 2G Exde II 2G Exde IIC T5 IIC T5 II 2G Exde II 2G Exde IIB+H2 T5 IIB+H2 T5 Motor & Terminal Box with Flame-Proof Enclosure II 2G Exd II 2G Exd II 2G Exd II 2G Exd IIB T5 IIB T5 IIB T5 IIB T5 180
280
315
-
-
II 2G Exde IIB+H2 T5
II 2G Exde IIB T5
II 2G Exd IIB T5
II 2G Exd IIB T5
VFD Rating FRAME
RANGE OF SPEED Torque Constant Ventilators - Pumps nN Rated Speed
TEMPERATURE CLASS
PARAMETERS OF FREQUENCY CONVERTER FOR MOTORS EcS.g(b) 160,180-EP-f
EcS.g(b) 200÷315-EP-f
Upeak < 0.75 kV
160 ÷ 280
T5
0.3 nN ÷ 1.2nN1)
0 ÷ nN
315
T5
0.8 nN ÷ 1.2nN1)
0 ÷ nN
cS.g(b) 160,180-EP-f
160 ÷ 280
T4
0.2 nN ÷ 1.2nN
1)
0 ÷ nN
Upeak < 1.25 kV
315
T4
0.7 nN ÷ 1.2nN1)
0 ÷ nN
Upeak < 1.0 kV dt > 0.1 us cS.g(b) 200÷315-EP-f Upeak < 1.6 kV dt > 0.1 us
*) The system motor converter given testing with converters: DANFOSS series VLT 5000 i 6000, SIEMENS series Simovert Masterdrivers and Vacon serii NX. 1
) nN ÷ 1.2nN - rated output constant.
Level of Noise [dB(A)] FRAME 160 180 200 225 250 280 315
POWER NOISE LWA / PRESSURE NOISE LpAf 3000 91/82 91/82 88/78 89/79 91/79 92/82 92/82
1500 75/66 78/69 79/69 83/73 85/75 85/75 86/76
1000 70/61 75/66 75/63 83/73 78/68 78/68 78/68
750 70/61 72/63 70/60 70/60 75/65 75/65 75/65
Also Available Upon Request
• Voltage to 750V • Frequency 60Hz • Protection Degree IP56 • Class “H” Insulation • Flame-Proof Terminal Box • Winding Thermal Protection • Bearing Thermal Protection
• Space Heaters in Winding • Terminal Box with 2 Cable Inlets • 6 Terminals for Star/Delta Starting • Adapted for Frequency Converter Supply • Rubber Packing of Cable Inlet for other cable’s diameter • Low Temperature Desgin (less than -20ºC) ... -ELT • GOST-R Certification
All Data Subject to Change Without Notice.. Elektrim Metric IEC Explosion Proof motors available upon special order only. Minimum quantities apply. Call Elektrim at 1-855-Go-Elektrim or 1-855-463-5358 for more information.
Dimensional Drawings (E)cSg(b) 160, 180 - EP
(E)cSg(b) 200 存 315 - EP
IM 1001, IM 1011, IM 1031, IM 1051, IM 1061, IM 1071
IM 1001, IM 1011, IM 1031, IM 1051, IM 1061, IM 1071
(E)cSLg(b) 160, 180 - EP
(E)cSLg(b) 200 存 315 - EP
IM 2001, IM 2011, IM 2031, IM 2051, IM 2061, IM 2071
IM 2001, IM 2011, IM 2031, IM 2051, IM 2061, IM 2071
(E)cSKg(b) 160, 180 - EP
(E)cSKg(b) 200 存 315 - EP
IM 3001, IM 3011, IM 3031
200-280: IM 4001, IM 4011, IM 4031 315: IM 3001, IM 3011, IM 3031
All Data Subject to Change Without Notice.. Elektrim Metric IEC Explosion Proof motors available upon special order only. Minimum quantities apply. Call Elektrim at 1-855-Go-Elektrim or 1-855-463-5358 for more information.
Mounting, Overall and Bearing Dimensions Mounting Dimensions SHAFT END FRAME 160 M 160 L 180 M 180 L 200L 225S 225M2 225M4-8 250M2 250M4-8 280S2 280S4-8 280M2 280M4 315S2 315S4-8 315M2 315M4-8
A
B
254 254 279 279 318 356 356 356 406 406 457 457 457 457 508 508 508 508
C
210 254 241 279 305 286 311 311 349 349 368 368 419 419 406 406 457 457
DM
108 108 121 121 133 149 149 149 168 168 190 190 190 190 216 216 216 216
M16 M16 M16 M16 M20 M20 M20 M20 M20 M20 M20 M20 M20 M20 M20 M20 M20 M20
FLANGE
Dm6
E
Fh9
GA
H-0.5
42k6 42k6 48k6 48k6 55 60 55 60 60 65 65 75 65 75 65 80 65 80
110 110 110 110 110 140 110 140 140 140 140 140 140 140 140 170 140 170
12 12 14 14 16 18 16 18 18 18 18 20 18 20 18 22 18 22
45 45 51.5 51.5 59 64 59 64 64 69 69 79.5 69 79.5 69 85 69 85
160 160 180 180 200 225 225 225 250 250 280-1 280-1 280-1 280-1 315-1 315-1 315-1 315-1
HA
K
22 22 22 22 32 34 34 34 37 37 40 40 40 40 46 46 46 46
wg PN IEC 72-1
LA
M±0.4
Njs
P
FF300 FF300 FF300 FF300 FF350 FF400 FF400 FF400 FF500 FF500 FF500 FF500 FF500 FF500 FF600 FF600 FF600 FF600
17 17 18 18 21 22 22 22 24 24 25 25 25 25 26 26 26 26
300 300 300 300 350 400 400 400 500 500 500 500 500 500 600 600 600 600
250 250 250 250 300 350 350 350 450 450 450 450 450 450 550js6 550js6 550js6 550js6
350 350 350 350 400 450 450 450 550 550 550 550 550 550 660 660 660 660
15 15 15 15 19 19 19 19 24 24 24 24 24 24 28 28 28 28
S Ø 18 18 18 18 18 18 18 18 18 18 18 18 18 18 22 22 22 22
T
QTY 4 4 4 4 4 8 8 8 8 8 8 8 8 8 8 8 8 8
5 5 5 5 5 5 5 5 5 5 5 5 5 5 6 6 6 6
Units in millimeters (mm).
Overall Dimensions FRAME
AA
AB
AC
AD
AD1
BA1
BA2
BB
BC±3
BL
HD
HD1
L
LB
160 M 160 L 180 M 180 L 200L2-8 225S4-6 225M2 225M4-8 250M2 250M4-8 280S2 280S4-8 280M2 280M4-8 315S2 315S4-8 315M2 315M4-8
60 60 65 65 80 85 85 85 95 95 100 100 100 100 105 105 105 105
300 300 330 330 400 445 445 445 495 495 560 560 560 560 610 610 610 610
360 360 400 400 465 510 510 510 550 550 620 620 620 620 625 625 625 625
185 185 185 185 190 190 190 190 190 190 190 190 190 190 190 190 190 190
315 315 335 335 400 420 420 420 440 440 485 485 485 485 500 500 500 500
60 60 65 65 105 115 115 115 120 120 140 140 140 140 140 140 140 140
60 60 105 105 105 120 120 120 120 120 170 170 170 170 185 185 185 185
256 300 330 330 388 385 385 385 445 445 500 500 500 500 550 550 550 550
23 23 27 27 44 47 47 47 57 57 51 51 51 51 45 45 45 45
60 60 65 65 70 75 75 75 85 85 85 85 85 85 130 130 130 130
475 475 515 515 600 645 645 645 690 690 765 765 765 765 815 815 815 815
440 440 480 480 560 610 610 610 670 670 770 770 770 770 770 770 770 770
670 710 765 765 810 860 830 860 915 915 1060 1060 1060 1060 1210 1240 1210 1240
610 650 715 715 770 795 795 795 850 850 995 995 995 995 1150 1150 1150 1150
min 20 20 26 26 32 32 32 32 38 38 44 44 44 44 52 52 52 52
dzas
max 25 25 31 31 37 37 37 37 43 43 49 49 49 49 55 55 55 55
Bearings SPEED (RPM) FRAME
3000 D1
160 180 200 225 250 280 315 1)
Drive End Side.
1500 ND2
N
6309 2ZC3 6311 2ZC3 NU 312 NU 313 NU 315 NU 315 NU 315 2)
1000 ND
N
6309 2ZC3 6311 2ZC3 6312 C3 6313 C3 6315 C3 6315 C3 6315 C3
NU 312 NU 313 NU 315 NU 317 NU 318
750 ND
N
6309 2ZC3 6311 2ZC3 6312 C3 6313 C3 6315 C3 6317 C3 6318 C3
NU 312 NU 313 NU 315 NU 317 NU 318
ND 6309 2ZC3 6311 2ZC3
6312 C3 6313 C3 6315 C3 6317 C3 6318 C3
NU 312 NU 313 NU 315 NU 317 NU 318
Non Drive End Side.
All Data Subject to Change Without Notice.. Elektrim Metric IEC Explosion Proof motors available upon special order only. Minimum quantities apply. Call Elektrim at 1-855-Go-Elektrim or 1-855-463-5358 for more information.
6312 C3 6313 C3 6315 C3 6317 C3 6318 C3
Permissible Free Shaft End Load on Drive Side radial load
axial load
FRAME
X=0
X=E
Horizontal
160M2A 160M2B 160M4 160M6 160M8A 160M8B 160L2 160L4 160L6 160L8 180M2 180M4 180L4 180L6 180L8 200L2A 200L2B 200L4 200L6A 200L6B 200L8 225S4 225S8 225M2 225M4 225M6 225M8 250M2 250M4 250M6 250M8 280S2 280S4 280S6 280S8 280M2 280M4 280M6 280M8 315S2 315S4 315S6 315S8 315M2A 315M2B 315M4A 315M4B 315M6A 315M6B 315M8A 315M8B
n 2000 1900 2500 3000 3400 3300 1900 2400 2800 3200 2600 3400 3300 3800 4300 8500 8300 10300 11700 11600 12800 12600 15700 10100 12400 14000 15500 13700 16700 18800 20600 13800 20900 24100 26300 13600 20700 23900 25900 13600 22500 25500 28100 13500 13400 22400 22200 25400 25100 27900 27700
N 1500 1500 2000 2300 2700 2600 1500 1900 2200 2500 2200 2800 2700 3200 3500 6900 6800 8400 9600 9500 10500 9900 12300 8300 9700 11000 12200 10900 13300 15000 16400 11400 17300 20000 21800 11300 17100 19800 21500 11700 18800 21300 23400 11600 11500 18600 18500 21100 20900 23300 23000
N 1500 1500 2100 2400 2700 2700 1400 2100 2400 2700 2100 2900 2800 3300 3600 2100 2000 2600 3300 3300 3700 2900 4100 2200 2800 3300 4100 2800 3500 4000 4900 2800 4100 4900 6000 2800 4100 4800 5300 2900 4600 5300 6600 2800 2700 4600 4400 5300 5000 5900 5600
• • •
Permissible load as a function of X is linear in the range from X=0 to X=E. Lh = 3000h- bearings life. For Lh = 40000h above values decrease about 20%.
All Data Subject to Change Without Notice.. Elektrim Metric IEC Explosion Proof motors available upon special order only. Minimum quantities apply. Call Elektrim at 1-855-Go-Elektrim or 1-855-463-5358 for more information.
Weight of Rotor
Vertical Down N 1300 1200 1800 2100 2500 2400 1200 1800 2000 2300 1700 2500 2400 2800 3100 1600 1500 2000 2700 2600 3000 2200 3400 1700 2100 2400 3200 2100 2600 2800 3700 1800 2800 3600 4600 1700 2500 3400 3700 1500 2800 3200 4500 1300 1100 2500 2300 3000 2500 3600 3100
Up N 1800 1800 2400 2700 3000 3000 1800 2500 2800 3100 2500 3400 3400 3900 4200 2600 2700 3400 4200 4200 4600 3700 5000 2900 3800 4400 5100 3700 4700 5600 6500 4200 5900 6500 7800 4200 6100 6700 7300 4700 6900 8000 9300 4700 4800 7100 7200 8100 8300 8700 8900
kg 24 27 29 30 26 30 31 35 39 37 37 45 50 55 55 50 56 70 77 84 81 75 81 62 87 98 94 81 108 141 141 119 158 146 156 129 176 164 182 160 205 237 237 170 186 227 245 253 289 253 289
European Engineered for Maximum Performance in Your Toughest Applications For over 40 years, Elektrim Motors has designed and manufactured a full line of AC NEMA and Metric IEC motors for the US marketplace. Our enthusiasm for motors and commitment to exacting standards mean that Elektrim Motors are some of the finest, longest lasting and best performing
in the industry. Elektrim Motors are European engineered for maximum performance, and are manufactured in state-ofthe-art ISO 9001 quality system facilities around the world. Trust the best. Get Elektrim.
NEMA MOTORS
IEC MOTORS WITH FOREIGN COOLING Special Order
IEC 1-PHASE INDUCTION MOTORS Special Order
IEC BRAKE MOTORS Special Order
IEC HIGH VOLTAGE IEC 3-PHASE INDUCTION MOTORS INDUCTION MOTORS Special Order
You Might Also Be Interested in These Elektrim Motor Products Metric three phase motors with squirrel cage rotor for standard and high efficiency
0.06kW up to 1400kW
general purpose, pumps, fans, compressors, specific requirements relating to the highest efficiency
Metric three phase squirrel cage high voltage motors in different frame and enclosures
160 kW up to 3150 kW
general industrial use, drives used for own needs of power plants (pumps, fans, coal mills, conveyors)
Metric three phase and single phase brake motors with AC and DC brakes
0.09 kW up to 160 kW
applied in case of necessity to stop the motor suddenly
0.04 kW up to 2kW
general purpose, pumps, fans, compressors, wood machines, machines and devices for food processing, mixers for building.
Metric three phase induction motors with foreign cooling
0.06 kW up to 18.5 kW
drives adapted for speed regulation by frequency converter
Low voltage NEMA Premium efficient 20N series motors
1 HP up to 250 HP
general industrial applications including fans, blowers, pumps
Metric single phase motors with squirrel cage rotor with: • standard starting torque • increased starting torque • high starting torque
2015 S. Mitchell Blvd., Schaumburg, IL 60193 +1-847-524-1074 • 855-463-5358 • Fax +1-847-524-9996 Elektrim is a trademark of Toolmex Industrial Solutions. www.elektrimmotors.com | 855-Go-Elektrim 4-999-6028 7-13 1.0