CLBKTXLan12-09-DisruptionOfAGreenApartment-GEnergy-JamesChua

Page 1

12th Green Architecture Conference

Disruption of a Green Apartment Presented by: James Chua ESD Director

15th April 2017
















Sustainability Sustainable development Has been defined as the development that meets the needs of the present without compromising the ability of future generations to meet their needs.


Sustainable housing is important in order to ensure a balanced consideration of social, environment and economic needs in the housing development sector. 

  

Successful – a strong partnership between all players in the development is a must. Should NOT be just government’s agenda, but Supported by all industry players, including: Architects, planners, developers as well as the society.


Sustainable Development means‌ Economic Success for the Future

Calm, Quality Social Developments

Apartment:Aesthetic, Healthy Environment


BCA Green Mark Assessment –



ENERGY EFFICIENCY – PASSIVE DESIGN STRATEGIES

TYPICAL BALCONY SECTION

RETV = 19.77 W/m2 GLASS SPECIFICATIONS LAMINATED GREEN TINTED

U-VALUE = 6.25 W/m2.K SC VALUE = 0.55

BALCONY PROJECTION SHADING DEVICE


ENERGY EFFICIENCY - PASSIVE DESIGN STRATEGIES 1. 2.

3.

USE OF PREVAILING WIND CONDITIONS STRATEGICALLY LOCATED WINDOWS FOR CROSSVENTILATION AVERAGE OF 0.7 TO 0.9 m/s WIND SPEED


ENERGY EFFICIENCY - PASSIVE DESIGN STRATEGIES NATURAL VENTILATION & DAYLIGHTING

CAR PARK 1. BASEMENT CAR PARK WITH LIGHT WELLS 2. DAYLIGHTING FROM SOUTH SIDE COMMON AREAS ARE NATURALLY VENTILATED & HAS ADEQUATE DAY LIGHTING

N


ENERGY EFFICIENCY - ACTIVE DESIGN STRATEGIES DUCTLESS FAN SYSTEM ENERGY EFFICIENT FEATURES

BASE MET CAR PAK DESIGNED WITH JET FAN SYSTEM FOR MECHANICAL VETILATION

SUN PIPES SUN PIPES ARE USED TO DAY LIGHT BASEMENT CAR PARK DRYING FACILITES APARTMENT YARD WILL HAVE CLOTHES DRYING FACILITES

GAS HEATERS APARTMENT WILL BE INSTALLED WITH GAS HEATES BASEMENT CAR PARK


Towards Sustainable & Eco-Friendly Living…..


SITE LAYOUT Minimum western sun exposure. Lushly designed communal deck and ground storey that provides a VIEW TO MARINA BAY buffer from the city. VIEW TO TOA PAYOH

Passive Energy Design Strategy: deep balconies, planter boxes, & bay windows and AC ledges that potentially shades the habitable area.

NORTH

VIEW TO ORCHARD AREA

Units are orientated 45degree away From direct western sun WEST

VIEW TO MACRITCHIE RESERVOIR

Overall Site Layout


Achieving

Sustainability through Passive Strategies:

Active Strategies

Lush Greenery at level 1 & 3 • Energy Efficient Air-conditioners • Energy Efficient Lighting • LIFTS – VVVF & Sleep Mode • Motion Sensors For staircase – half-landing, lift lobbies & common areas • Gas heaters • Heat Recovery devices • Monitor the water Usage through Submeters

Efficient façade Design for Effective Shading through • Balconies • Bay Windows • AC Ledges High performance Glazing with “Better SC and UValue” Comfortable Indoor NOISE levels through Deep Balconies Ample Daylight for indoor


CAR PARK - 1ST STOREY

Bicycle lots

Air wells for Natural Ventilation & Daylighting

Floor Plans _ An Overview


CAR PARK - 2ND STOREY

Air wells for Natural Ventilation & Daylighting

Floor Plans _ An Overview


Pre - Requisites Min Req.

Current Standing

20 W/m2

19.85 W/m2

Mandatory

Complied

1

Building Envelope – RETV

2

CFD – Endure Good Natural Ventilation

Typical Elevation

No. Category

ENERGY EFFICIENCY


Design for Natural Ventilation – Use of Ventilation Simulation Software

To enhance building design to achieve good natural ventilation in common areas like staircases, lobbies and corridors.

North wind @ 2m/s

ENERGY EFFICIENCY


Water Efficiency Fittings Estimated Savings/Year From WELS fittings: $ 11,337.20 DESCRIPTION -To encourage the use of renewable energy sources in buildings

IMPLEMENTATION Labelling Scheme (WELS) -Water efficient and fittings efficiency

for enhanced

IMPLEMENTATION

Target Points

Basin tap and mixers

0.5

Flushing cistern

1

Showers

0

Sink/bib taps and mixers

0.5

TOTAL

2.0

WELS rating

Water Efficienc y

Weightage for Points Allocation

Good

0.5

√√

Very good

1

√√√

Excellent

2

Water Efficiency: Water Efficient Fittings


No.

Category

RB 2-1

Water Efficiency Fittings

Max. Point

Target Point

10

2

Water Efficiency: Water Efficient Fittings


Range of Green Cost Premiums & Payback Periods vs. Level of Green Certification


Sunway Pyramid Shopping Mall RETROFITTING WORKS DONE

Complete replacement of chiller plant room system and upgrading of CPA System

POTENTIAL SAVINGS

RM 3,000,000 per Annum

EXPECTED PAYBACK

6 Years

PROJECT COMPLETION

2013

ACHIEVED PLANTROOM EFFICIENCY

0.70 kW/ton

G-ENERGY'S ROLE

Acted as Energy Consultant to perform detail energy audit, provide recommendations, detail design and project management to enhance existing design specifications to ensure the chiller plant room system is efficient and flexible in operation.




Great Things are NOT Done by impulse, but by A series of small things brought together Vincent van Gogh


Disruption of a Green Apartment 

 

Architecture education should focus on imagination, creativity and teamwork only Teach music, sports and arts Music and arts to help our architects to be more creativity and imaginative Sports to make our architects know what is teamwork The future on a Green Apartment is not about competition of knowledge

 BUT,

wisdom and experience


DISRUPTIVE ENERGY SYSTEM

G-Energy Global The Energy & Sustainable Design Specialist


12th Green Architecture Conference

Disruption of a Green Apartment

Presented by: James Chua ESD Director

james@genergy.com.sg +65-9850 3231 +60-123 966 590

15th April 2017


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.