Wide Span Roof Fabrication

Page 1

Important Information

WIDE SPAN ROOFS Due to extensive testing we are now delighted in being able to offer increased widths across our roofing range. Geogians upto 6300mm and Victorians upto 6500mm wide.

The following procedures must be followed step by step when installing a wide span roof:

1

4

Join the eaves together using one of the external corner connecting brackets (XSC1) using four supplied 12mm fixing screws (XM48-12). Make sure the bracket is positioned between the two die-lines in the eaves beam.

2

Fit the hip rafter and place the remaining angled cornerconnecting bracket over the tie bolt and fit and fully tighten the 13mm fixing nut.

5

On wide span roofs two angled corner connecting brackets are supplied per corner. Fit one to the top outer eaves beam corner and fix with four supplier fixings screws (XM48-12) as shown.

Finally install all four supplied fixings screws. (XM48-12)

Due to the increased loadings throughout the roof and frame structure it is important that care is taken in using suitable fixings to secure the frames and roof to the host wall.

3

Extra care is required in making sure all of the fixings are fully tightened as failure to do so could potentially lead to movement within the conservatory structure.

Using a 4mm allen key fully tighten both of the tie bolts in the hip rafter. 047OCT11/v1