Velinfor catalog 2020

Page 1

Optimal Solutions for Optical Networks

velinfor.com


Content About us Our Advantages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Certification and Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Cables Coding of Optical Fiber Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Color Coding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Aerial Flexible Round Cable A/J-D(ZN-AY)H-XE-0.5KN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Aerial Round Cable A-D(ZN-2P)2Y-XE-1.0 KN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Aerial Round Cable A-D(ZN-2P)2Y-XE-1.5 KN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Flexible Round Cable A-D(ZN-RGY)2Y-XE-1.8 KN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Aerial Flexible Round Cable A/J-D(ZN-RGY)H-XE-1.8 KN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Aerial Flat Cable A-D(ZN-2P)2Y-XE-1.0 KN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Round Armored Cable A-DF(ZN-SR)2Y-XTYE-1.5KN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Round Flex Micro Cable A-DQ(ZN-)2Y-XTYE for Blowing to Pipes. . . . . . . . . . . . . . . . . . . . . . . . . . 9 Outdoor Flex Round Cable A-DQ(ZN-GY)2Y-XTYE-1.5KN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Outdoor Round Cable A-DQ(ZN-RAY)2Y-XTYE-3.5KN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Outdoor Round Cable A-DQ(ZN-GY)2Y-XTYE-2.0KN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

2

Tension and Suspension Cable Clamps Drop Wire Clamp for FTTH Network H15 Fiber Optic Wedge Clamp. . . . . . . . . . . . . . . . . . Wedge Type Tension Clamp H3 Anchor Clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Anchoring Tension Clamp H20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Anchoring Tension Clamp H28 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12 12 13 13

Fiber Optic Splice Closures Pole, Hook Bracket CS100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stainless Steel Tape 19x0,7mm AISI 201 50m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Belt Buckle for Stainless Steel Band 18mm-201/304-20mm-304. . . . . . . . . . . . . . . . . . . . . . . . . . Microducts for Fibre Optical Cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fiber Optic Splice Closure Pole-Mounted Joint Box Tracom MDU B16 . . . . . . . . . . . . . . . . . . . . . Fiber Optic Splice Closure - up to 144 Fibres. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fiber Optic Splice Closure Tracom SC H2 (48J: 4Xpo35) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14 14 14 15 16 16 17


About us Our Advantages

Materials

E.A.A Coated Rods

Control

Use of materials only from world leaders.

We use of fiberglass E.A.A. coated rods, it allows rods to glue to cable covering, cable has better structural integrity that makes cable stronger, cable is thinner and lighter. Such cable more weather resistant: wind and icing, its logistics cheaper.

The company has implemented a through barcoding system at all stages of production, thus we have the ability to monitor the quality at all stages of production.

Aerial cables with fiber margin

Production

Service

The total production capacity is 2,800 km per month. Terms of order execution from 1 day. Easy setup on different designs. Highly skilled technologists in the field of production of fiber-optic products.

Prompt response to any questions the customer. Management according the West European sample.

The design of the cable involves operation taking into account possible natural stretching without the effect ÂŤrunning awayÂť of fibers. The cable have special inside fiber margin not less 0.4%.

Certification and Warranty The company is certified according to ISO 9001:2015 and ISO 14001:2015 by TUV Nord Cerf. Products CRP compliant EN 50575. Official warranty on cable - 4 years

3


Cables Coding of Optical Fiber Cables (based on DIN 0888)

A J

– Outdoor cable – Indoor cable

Flat – flat outdoor cable Flex – flexible outdoor cable Micro – cable with micro tubes

W – Singel fiber in loose tube filled in with gel D – Several fibers in loose tube filled in with gel K – Fiber in a semi-dense buffer (without gel) V – Fiber in tight buffer

Y – P.V.C. outside jacket 2Y – Polyethylene (РЕ) outside jacket 4Y – Polyamide (PA) outside jacket 11Y – Polyurethane (PUR) outside jacket H – LSZH outside jacket - with low smoke emission and zero halogen content

Maximum tension load

FLAT A - D 2S Q ( ZN - GY ) 2Y - XTY E - 2.0KN E – Single-mode fiber G – Multi-mode fiber

nS – Power conductive elements of construction in the central part of the cable n – Quantity of conductive elements Q – The cable contains a special waterproof tape F – Cable core filled in with gel ZM – Metallic strength member ZN – Non-metallic strength member 8 –External strength member (outdoor cable figure 8 shape)

m – Fiber quantity in monotube design nTm-n – quantity of tubes m – fiber quantity in each tube SR – Inner jacket with corrugated steel tape nP – FRP rods, n-quantity R – Antirodent protexction GY – Glass yarn AY – Aramid yarn

Example of coding optical cables:

4

Flex A/J-D(ZN-RGY)H-24E-1.8kN

A-D(ZN-2P)2Y-12E-1.0kN

A-DF(ZN-GYSR)2Y-6T4E-2.7kN

flexible cable for external and internal use, construction – free tube, filled with gel, non-metallic strength elements – glass yarn, anti-rodent protection, LSZH outside jacket, 24 single mode fibers, tension load – 1.8kN.

cable for external use, construction – free tube, filled with gel, non-metallic strength elements – two FRP rods, polyethylene outside jacket, 12 single mode fibers, tension load – 1.0kN.

cable for external use, multi-tube design, tubes are filled with gel, cable contains a special waterproof tape, strength elements – glass yarn, protection by corrugated steel tape, six tubes with four fibers each one, polyethylene outension load – 2.7kN.


Color Coding UTEX typical IEC 60304 DIN VDE0888 Fiber 1

2

3

4

5

6

7

8

9

10

11

12

Red RD

Green GN

Blue BU

Yellow YE

White WH

Gray GY

Brown BN

Violet VT

Turquoise TQ

Black BK

Orange OG

Pink PK

Tube 1

2

Red RD

Green GN

White WH - count clockwise

TIA/EIA/ ANSI 598 Fiber 1

2

3

4

5

6

7

8

9

10

11

12

Blue BU

Orange OG

Green GN

Brown BN

Gray GY

White WH

Red RD

Black BK

Yellow YE

Violet VT

Pink PK

Turquoise TQ

1

2

3

4

5

6

7

8

9

10

11

12

Blue BU

Orange OG

Green GN

Brown BN

Gray GY

White WH

Red RD

Black BK

Yellow YE

Violet VT

Pink PK

Turquoise TQ

Tube

Color coding can be according customer requiements.

5


Cables AERIAL FLEXIBLE ROUND CABLE A/J-D(ZN-AY)H-XE-0.5KN The outdoor and indoor aerial fiber optic cable Flex A/J-D(ZN-AY)H-XE-0.5KN designed for installation on short distance between telecommunication or electrical line poles, city light poles, buildings or other constructions, along building walls, inside building. Used as “last mile” for connecting subscribers and indoor network breeding.

Cable Design: Fiber: • Single Mode fiber G.657 А2 • 1÷4 fibers • Central tube gel-filled • Color coding per IEC 60304 - DIN VDE0888 Outer jacket: • LSZH compound • UV resistant • Sequential meter marking Features: • Central tube armored aramid yarn

Typical cross-section

• Flexible and easy to install

LSZH Compound

Performance:

Aramid Yarn Optic Fiber

• Temperature: installation -20°C to +50°C operating -40°C to +60°C

Optic Tube

• Minimum band radius 15 nominal diameters of cable • Maximum crash resistance 200 N/cm • Maximum tension load 500 N

Catalogue number

Number of fibers

Diameter (mm)

Weight (kg/ km)

Flex A/J-W(ZN-AY)H-1E-0.5kN

1

3,0

7,4

Flex A/J-D(ZN-AY)H-2E-0.5kN

2

3,0

7,5

Flex A/J-D(ZN-AY)H-4E-0.5kN

4

3,0

7,7

Mechanical characteristics: • Max distance between poles – 30 m* • Max sagging – 2% • Cable weight – see table • Cable diameter – see table • Cable length – 2 to 4 km/reel *This length is indicated for regions with a minimum wind exposure and icing

AERIAL ROUND CABLE A-D(ZN-2P)2Y-XE-1.0 KN The outdoor aerial fiber optic cable A-D(ZN-2P)2Y-XE-1.0 KN designed for installation on telecommunication or electrical line poles, city light poles, between buildings or other constructions, along building walls.

Cable Design: Fiber: • Single Mode fiber G.652 D • 1÷24 fibers • Central tube gel-filled • Color coding per IEC 60304 - DIN VDE0888 Outer jacket: • Black high density polyethylene (HDPE) • Sequential meter marking

Typical cross-section

Features:

Optical Fibers

• Central tube armored two FRP E.A.A coated rods

Water Blocking Gel

• Resistant to tension loads and shell stretching

Central Tube

Performance:

Strength FRP Rod

• Temperature: installation -20°C to +50°C operating -40°C to +60°C

PE Jacket

6

• Minimum band radius 15 nominal diameters of cable • Maximum crash resistance 200 N/cm

Catalogue number

Number of fibers

Diameter (mm)

Weight (kg/km)

A-W(ZN-2P)2Y-1E-1,0kN

1

4,5

17,7

A-D(ZN-2P)2Y-2E-1,0kN

2

4,5

17,8

• Max distance between poles – 80 m*

A-D(ZN-2P)2Y-4E-1,0kN

4

4,5

17,9

• Max sagging – 2%

A-D(ZN-2P)2Y-8E-1,0kN

8

5,5

27,5

• Cable weight – see table

A-D(ZN-2P)2Y-12E-1,0kN

12

5,5

27,7

• Cable diameter – see table

A-D(ZN-2P)2Y-16E-1,0kN

16

6,0

32,4

• Cable length – 2 to 4 km/reel

A-D(ZN-2P)2Y-24E-1,0kN

24

6,0

32,7

• Maximum tension load 1000 N Mechanical characteristics:

*This length is indicated for regions with a minimum wind exposure and icing


AERIAL ROUND CABLE A-D(ZN-2P)2Y-XE-1.5 KN Cable Design:

The outdoor aerial fiber optic cable A-D(ZN-2P)2Y-XE-1.5 KN designed for installation on telecommunication or electrical line poles, city light poles, between buildings or other constructions, along building walls.

Fiber: • Single Mode fiber G.652 D • 1÷24 fibers • Central tube gel-filled • Color coding per IEC 60304 - DIN VDE0888 Outer jacket: • Black UV resistant polyethylene (PE) • Sequential meter marking

Typical cross-section

Features: • Central tube armored two FRP E.A.A coated rods

Optical Fibers

• Resistant to tension loads and shell stretching

Water Blocking Gel

Performance:

Central Tube

• Temperature: installation -20°C to +50°C operating -40°C to +60°C

Strength FRP Rod PE Jacket

• Minimum band radius 15 nominal diameters of cable • Maximum crash resistance 200 N/cm

Catalogue number

Number of fibers

Diameter (mm)

Weight (kg/km)

A-W(ZN-2P)2Y-1E-1,5kN

1

5,0

21,7

A-D(ZN-2P)2Y-2E-1,5kN

2

5,0

21,7

• Max distance between poles – 90 m*

A-D(ZN-2P)2Y-4E-1,5kN

4

5,0

21,7

• Max sagging – 2%

A-D(ZN-2P)2Y-8E-1,5kN

8

6,0

30,3

• Cable weight – see table

A-D(ZN-2P)2Y-12E-1,5kN

12

6,0

30,5

A-D(ZN-2P)2Y-16E-1,5kN

16

6,4

34,3

A-D(ZN-2P)2Y-24E-1,5kN

24

6,4

34,6

• Maximum tension load 1500 N Mechanical characteristics:

• Cable diameter – see table • Cable length – 2 to 4 km/reel *This length is indicated for regions with a minimum wind exposure and icing

FLEXIBLE ROUND CABLE A-D(ZN-RGY)2Y-XE-1.8 KN The outdoor and indoor aerial fiber optic cable A-D(ZN-RGY)2Y-XE-1.8 KN designed for installation between telecommunication or electrical line poles, city light poles, buildings or other constructions, along building walls, inside building, in cable ducts, cable runs, pipes, tunnels, including with rodents.

Cable Design: Fiber: • Single Mode fiber G.652 D • X — 2÷24 fibers • Central tube gel-filled • Color coding per IEC 60304 - DIN VDE0888 Outer jacket: • Black UV resistant polyethylene (PE) • Sequential meter marking Features:

Typical cross-section

• Strength member and protection by rodent - glass yarns around tube

PE jacket

• Flexible and easy to install

Fiber Glass Yarns

Performance:

Optical Fiber

• Temperature: installation -10°C to +50°C operating -40°C to +60°C

Optical Tube Rip-Cord

• Minimum band radius 15 nominal diameters of cable • Maximum crash resistance 200 N/cm

Catalogue number

Fiber count

Cable diameter, mm

Tube diameter, mm

Weight (kg/km)

Flex А/J-D(ZN-RGY)2Y-2E-1,8kN

2

6,0

3,0

24,0

• Cable weight – see table

Flex А/J-D(ZN-RGY)2Y-4E-1,8kN

4

6,0

3,0

24,2

• Cable diameter – see table

Flex А/J-D(ZN-RGY)2Y-8E-1,8kN

8

6,4

3,5

34,4

• Cable length – 2 to 4 km/reel

Flex А/J-D(ZN-RGY)2Y-12E-1,8kN

12

6,4

3,5

34,5

Flex А/J-D(ZN-RGY)2Y-24E-1,8kN

24

6,8

4,0

38,9

• Maximum tension load 1800 N Mechanical characteristics:

7


Cables AERIAL FLEXIBLE ROUND CABLE A/J-D(ZN-RGY)H-XE-1.8 KN The outdoor and indoor aerial fiber optic cable A/J-D(ZN-RGY)H-XE-1.8 KN designed for installation between telecommunication or electrical line poles, city light poles, buildings or other constructions, along building walls, inside building, in cable ducts, cable runs, pipes, tunnels, including with rodents.

Cable Design: Fiber: • Single Mode fiber G.652 D • X — 2÷24 fibers • Central tube gel-filled • Color coding per IEC 60304 - DIN VDE0888 Outer jacket: • LSZH compound • UV resistant • Sequential meter marking

Typical cross-section

Features:

LSZH compound

• Strength member and protection by rodent - glass yarns around tube

Fiber Glass Yarns

• Flexible and easy to install

Optical Fiber

Performance:

Optical Tube

• Temperature: installation -10°C to +50°C operating -40°C to +60°C

Rip-Cord

Catalogue number

Fiber count

Cable diameter, mm

Tube diameter, mm

Weight (kg/km)

Flex А/J-D(ZN-RGY)Н-2E-1,8kN

2

6,0

3,0

42,0

Flex А/J-D(ZN-RGY)Н-4E-1,8kN

4

6,0

3,0

42,2

Flex А/J-D(ZN-RGY)Н-8E-1,8kN

8

6,4

3,5

43,8

Flex А/J-D(ZN-RGY)Н-12E-1,8kN

12

6,4

3,5

44,0

Flex А/J-D(ZN-RGY)Н-24E-1,8kN

24

6,8

4,0

49,0

• Minimum band radius 15 nominal diameters of cable • Maximum crash resistance 200 N/cm • Maximum tension load 1800 N Mechanical characteristics: • Cable weight – see table • Cable diameter – see table • Cable length – 2 to 4 km/reel

AERIAL FLAT CABLE A-D(ZN-2P)2Y-XE-1.0 KN The outdoor aerial fiber optic cable A-D(ZN-2P)2Y-XE-1.0 KN designed for installation on telecommunication or electrical line poles, city light poles, between buildings or other constructions, along building walls.

Cable Design: Fiber: • Single Mode fiber G.652 D • 1÷24 fibers • Central tube gel-filled • Color coding per IEC 60304 - DIN VDE0888 Outer jacket: • Black UV resistant polyethylene (PE) • Sequential meter marking

Typical cross-section

Features:

Optical Fibers

• Central tube armored two FRP E.A.A coated rods

Water Blocking Gel

• Resistant to tension loads and shell stretching

Oprical Tube

Performance:

Strength Rod

• Temperature: installation -20°C to +50°C operating -40°C to +60°C

PE Jacket

8

• Minimum band radius 60 mm – installation 90 mm – operating

Catalogue number

Number of fibers

Cable sizes (mm)

Weight (kg/km)

Flat A-W(ZN-2P)2Y-1E-1,0kN

1

2.6×5.6

15,4

Flat A-D(ZN-2P)2Y-2E-1,0kN

2

2.6×5.6

15,4

Flat A-D(ZN-2P)2Y-4E-1,0kN

4

2.6×5.6

15,5

• Max distance between poles – 70 m*

Flat A-D(ZN-2P)2Y-8E-1,0kN

8

3.3×6.0

16,2

• Max sagging – 2%

Flat A-D(ZN-2P)2Y-12E-1,0kN

12

3.3×6.0

16,3

• Cable weight – see table

Flat A-D(ZN-2P)2Y-16E-1,0kN

16

3.8×7.2

21,8

Flat A-D(ZN-2P)2Y-24E-1,0kN

24

3.8×7.2

21,9

• Maximum crash resistance 400 N/cm • Maximum tension load 1000 N Mechanical characteristics:

• Cable diameter – see table • Cable length – 2 to 4 km/reel *This length is indicated for regions with a minimum wind exposure and icing


ROUND ARMORED CABLE A-DF(ZN-SR)2Y-XTYE-1.5KN The cable A-DF(ZN-SR)2Y-XTYE-1.5KN is armored corrugated steel laminated tape and designed for manual and automated methods of installation into soil of all categories, cable ducts, blocks and other areas with high hazard of rodents.

Cable Design: Fiber: • Single Mode fiber G.652 D • X – tubes, Y - fibers • Tubes filled with water resistant gel • Color coding per IEC 60304 - DIN VDE0888 Outer jacket: • Black UV resistant polyethylene (PE)

Typical cross-section

• Sequential meter marking

PE jacket Water Blocking Gel Optical Fibers Strenght Member Optical Tube Dummy Filler (cordel) Corrugated armored steel

Features: • Central FRP rod strength member • Protection by rodent is corrugated laminated steel tape Performance: • Temperature: installation -20°C to +50°C operating -40°C to +60°C • Minimum band radius 15 nominal diameters of cable

Catalogue number

Number of fibers

Diameter (mm)

Weight (kg/km)

A-D(ZN-SR)2Y-1T4E-1.5kN

4

10,5

95,9

A-D(ZN-SR)2Y-2T4E-1.5kN

8

10,5

96,5

A-D(ZN-SR)2Y-3T4E-1.5kN

12

10,5

97,0

• Cable weight – see table

A-D(ZN-SR)2Y-4T4E-1.5kN

16

10,5

97,5

• Cable diameter – see table

A-D(ZN-SR)2Y-6T4E-1.5kN

24

10,5

98,5

• Cable length – 2 to 4 km/reel

A-D(ZN-SR)2Y-6T6E-1.5kN

36

10,5

98,8

A-D(ZN-SR)2Y-6T8E-1.5kN

48

10,5

99,1

A-D(ZN-SR)2Y-8T8E-1.5kN

64

11,8

117,9

A-D(ZN-SR)2Y-6T12E-1.5kN

72

10,5

103,3

A-D(ZN-SR)2Y-8T12E-1.5kN

96

12,0

131,5

A-D(ZN-SR)2Y-12T12E-1.5kN

144

14,5

176,1

• Maximum crash resistance 300 N/cm • Maximum tension load 1500 N Mechanical characteristics:

ROUND FLEX MICRO CABLE A-DQ(ZN-)2Y-XTYE FOR BLOWING TO PIPES The cable with micro-tubes designed for pneumatic blowing in tubes. Also available installation inside buildings and structures on walls, in vertical and horizontal cable lines, between floors, in cable sewage system, pipes, cable trays, blocks and tunnels, except including rodent damage.

Cable Design: Fiber: • Single Mode fiber G.652 D • X – tubes, Y - fibers • Tubes filled with water resistant gel • Color coding per IEC 60304 - DIN VDE0888 Outer jacket:

Typical cross-section

• Black UV resistant polyethylene (PE)

PE jacket Water Blocking Yarn Optical Fibers Optical Micro Tubes Central Strenght Rip-cord Filler (cordel)

• Sequential meter marking Features: • Strength member - central FRP rod • Sequential meter marking Performance: • Temperature: installation -20°C to +50°C operating -40°C to +60°C

Catalogue number

Number of fibers

Diameter (mm)

Weight (kg/km)

Micro A-DQ(ZN)2Y-2T6E-1kN

12

5,6

21,1

• Minimum band radius 15 nominal diameters of cable

Micro A-DQ(ZN)2Y-2T12E-1kN

24

5,6

26,6

• Maximum crash resistance 200 N/cm

Micro A-DQ(ZN)2Y-3T12E-1kN

36

5,6

23,9

• Maximum tension load 1000 N

Micro A-DQ(ZN)2Y-4T12E-1kN

48

5,6

26,3

Micro A-DQ(ZN)2Y-6T12E-1kN

72

5,6

29,2

• Cable weight – see table

Micro A-DQ(ZN)2Y-8T12E-1kN

96

6,5

24,8

• Cable diameter – see table

Micro A-DQ(ZN)2Y-12T12E-1.5kN

144

8,4

54,8

Mechanical characteristics:

• Cable length – 2 to 4 km/reel

9


Cables OUTDOOR FLEX ROUND CABLE A-DQ(ZN-GY)2Y-XTYE-1.5KN Outdoor dielectric round cable A-DQ(ZN-GY)2Y-XTYE-1.5KN designed for installation on telecommunication or electrical line poles, city light poles, between buildings or other constructions, installation in cable ducts, cable runs, pipes, tunnels, except including rodent damage.

Cable Design: Fiber: • Single Mode fiber G.652 D • X – tubes, Y - fibers • Tubes filled with water resistant gel • Color coding per IEC 60304 - DIN VDE0888 Outer jacket: • Black UV resistant polyethylene (PE) • Sequential meter marking

Typical cross-section

Features:

PE jacket Optical Fibers Water Blocking Yarn Optical Tube Central FRP Rod Glass Yarn Dummy Filler (cordel) Rip-cord

• Strength member - central FRP rod and glass yarn around tubes • Sequential meter marking • Dummy fillers (cordel) for additional feeling of structure Performance:

Catalogue number

Number of fibers

Cable sizes (mm)

Weight (kg/km)

FLEX А-DQ(ZN-GY)2Y-1T12E 1.5KN

12

8,0

49,5

FLEX А-DQ(ZN-GY)2Y-2T12E 1.5KN

24

8,0

50,7

FLEX А-DQ(ZN-GY)2Y-3T12E 1.5KN

36

8,0

52,0

FLEX А-DQ(ZN-GY)2Y-4T12E 1.5KN

48

8,0

53,2

FLEX А-DQ(ZN-GY)2Y-8T12E 1.5KN

96

10,4

89,2

• Temperature: installation -5°C to +50°C operating -40°C to +60°C • Minimum band radius 15 nominal diameters of cable • Maximum crash resistance 300 N/cm • Maximum tension load 1500 N Mechanical characteristics: • Cable weight – see table • Cable diameter – see table • Cable length – 2 to 4 km/reel

OUTDOOR ROUND CABLE A-DQ(ZN-RAY)2Y-XTYE-3.5KN Outdoor dielectric round cable A-DQ(ZN-RAY)2Y-XTYE-3.5KN designed for installation between telecommunication or electrical line poles, city light poles, buildings or other constructions, along building walls, inside building, in cable ducts, cable runs, pipes, tunnels, including with rodents.

Cable Design: Fiber: • Single Mode fiber G.652 D • X – tubes, Y - fibers • Tubes filled with water resistant gel • Color coding per IEC 60304 - DIN VDE0888 Outer jacket: • Black UV resistant polyethylene (PE) • Sequential meter marking

Typical cross-section

Features: • Strength member - central FRP rod and glass yarn around tubes

PE jacket Optical Fibers Water Blocking Yarn Optical Tube Central FRP Rod Aramid Yarn Dummy Filler (cordel)

10

• Protection by rodent - aramid yarn around tube • Sequential meter marking • Dummy fillers (cordel) for additional feeling of structure Performance: • Temperature: installation -5°C to +50°C operating -40°C to +60°C

Catalogue number

Number of fibers

Diameter (mm)

Weight (kg/km)

A-DQ(ZN-RAY)2Y-06T04E-3.5kN

24

8,4

56,0

A-DQ(ZN-RAY)2Y-06T08E-3.5kN

48

8,4

67,4

A-DQ(ZN-RAY)2Y-08T08E-3.5kN

64

9,6

74,4

A-DQ(ZN-RAY)2Y-06T12E-4.0kN

72

9,0

66,9

• Cable weight – see table

A-DQ(ZN-RAY)2Y-08T12E-4.0kN

96

10,2

82,3

• Cable diameter – see table

A-DQ(ZN-RAY)2Y-12T12E-4.0kN

144

12,8

126,6

• Cable length – 2 to 4 km/reel

• Minimum band radius 15 nominal diameters of cable • Maximum crash resistance 300 N/cm • Maximum tension load 3500 (4000) N Mechanical characteristics:


OUTDOOR ROUND CABLE A-DQ(ZN-GY)2Y-XTYE-2.0KN Outdoor dielectric round cable A-DQ(ZN-GY)2Y-XTYE-2.0KN designed for installation on telecommunication or electrical line poles, city light poles, between buildings or other constructions, installation in cable ducts, cable runs, pipes, tunnels, except including rodent damage.

Cable Design: Fiber: • Single Mode fiber G.652 D • X – tubes, Y - fibers • Tubes filled with water resistant gel • Color coding per IEC 60304 - DIN VDE0888 Outer jacket: • Black UV resistant polyethylene (PE) • Sequential meter marking

Typical cross-section

Features:

PE jacket Optical Fibers Water Blocking Yarn Optical Tube Central FRP Rod Glass Yarn Water Blocking Gel Dummy Filler (cordel)

• Strength member - central FRP rod and glass yarn around tubes • Sequential meter marking • Dummy fillers (cordel) for additional feeling of structure Performance:

Catalogue number

Number of fibers

Cable sizes (mm)

Weight (kg/km)

A-DQ(ZN-GY)2Y-01T04E-2kN

4

9,0

68,3

A-DQ(ZN-GY)2Y-02T04E-2kN

8

9,0

66,4

A-DQ(ZN-GY)2Y-03T04E-2kN

12

9,0

66,7

A-DQ(ZN-GY)2Y-04T04E-2kN

16

9,0

67,1

A-DQ(ZN-GY)2Y-04T06E-2kN

24

9,0

67,2

A-DQ(ZN-GY)2Y-04T08E-2kN

32

9,0

67,7

A-DQ(ZN-GY)2Y-06T06E-2kN

36

9,0

68,2

A-DQ(ZN-GY)2Y-06T08E-2kN

48

9,0

69,0

A-DQ(ZN-GY)2Y-08T08E-2kN

64

10,5

80,3

A-DQ(ZN-GY)2Y-08T12E-2kN

96

10,5

87,2

A-DQ(ZN-GY)2Y-12T12E-2kN

144

11,8

117,5

• Temperature: installation -5°C to +50°C operating -40°C to +60°C • Minimum band radius 15 nominal diameters of cable • Maximum crash resistance 300 N/cm • Maximum tension load 2000 N Mechanical characteristics: • Cable weight – see table • Cable diameter – see table • Cable length – 2 to 4 km/reel

11


Tension and Suspension Cable Clamps DROP WIRE CLAMP FOR FTTH NETWORK H15 FIBER OPTIC WEDGE CLAMP We provide the best quality anchoring and wedgeshaped clamps for optical fiber cable suspension in the construction of aerial fiber infrastructure. Anchoring, drop wire clamp for FTTH network - wedge tension cable clamp H15 is suitable for cables with the diameter from 0,08 to 0,27” (2-7 mm) of the following wedge types: • for self-supporting aerial cable; • for ADSS cables; • for fiber optic cable; • for ethernet cable; • for network cables; • for round aerial cable; • for oval or flat cable; • for electrical cable; • for telecom cables; • for FTTH cables.

Technical characteristics: • Maximum spans between fastening points 131 ft. (40m) • Working load - up to 0.5 kN • Breaking load - 1.1 kN • Loop thickness - 0,11” (3 mm) • Operating temperatures -40 to +140°F (-40°C – +60°C)

WEDGE TYPE TENSION CLAMP H3 ANCHOR CLAMP Anchoring, wedge-shaped tension clamp H3 is suitable for self-supporting aerial or ADSS cables with diameter from 0,19 to 0,23” (5-7mm) and for cables with external strength member (Figure-8 like). Technical characteristics: • Clamp H3 consists of a plastic frost resistant body, polymeric wedges and bail made of hot-dip galvanized steel • Installation does not require baring or separation of the supporting element and do not cause any damage to the sheath. • Easy manual installation without any tools. • Maximum spans between fastening points – 262 ft.(80m) • Working load - up to 1,8 kN • Operating temperatures -40 to +140°F (-40°C – +60°C) • Distinctive feature of our clamps is that under extreme conditions (frosting, trees falling, hurricanes, etc.)the clamp is destroyed without damage to the cable what, in some cases, prevents line breakage.

12


ANCHORING TENSION CLAMP H20 Anchoring, wedge-shaped tension clamp H28 is suitable for self-supporting figure-8 cables with external strength member and circular cables with diameter from 0,15” - 0.24” (4,5 to 6,5 mm). Technical characteristics: • Anchoring clamp H20 consists of a plastic UV and frost resistant body, polymeric wedges and bail made of hot-dip galvanized steel. • Installation does not require baring or separation of the supporting element and do not cause any damage to the sheath or overall signal loss. • Easy manual installation without any tools. • Operating temperatures from -40 to +140°F (-40°C – +60°C) • Maximum spans between fastening points – 394 ft.(120m) • Weight - 5.46 oz (154 gr) • Working load - up to 2 kN • Distinctive feature of our clamps is that under extreme conditions (frosting, trees falling, hurricanes, etc.) the clamp is destroyed without damage to the cable what, in some cases, prevents line breakage.

ANCHORING TENSION CLAMP H28 Anchoring, wedge-shaped tension clamp H20 is suitable for self-supporting circular cables (ADSS like) with diameter from 0.3” to 0.5” (8 to 12 mm).

Technical characteristics: • Anchoring clamp H20 consists of a plastic UV and frost resistant body, polymeric wedges and bail made of hot-dip galvanized steel. • Installation does not require baring or separation of the supporting element and do not cause any damage to the sheath or overall signal loss. • Easy manual installation without any tools. • Operating temperatures from -40 to +140°F (-40°C – +60°C) • Maximum spans between fastening points – 394 ft.(120m) • Weight - 5.46 oz (154 gr) • Working load - up to 2 kN • Distinctive feature of our clamps is that under extreme conditions (frosting, trees falling, hurricanes, etc.) the clamp is destroyed without damage to the cable what, in some cases, prevents line breakage.

13


Fiber Optic Splice Closures POLE, HOOK BRACKET CS100 Pole bracket with hook. It can be mounted by using 20 mm tapes. Shipping weight: 0.50 kg

STAINLESS STEEL TAPE 19x0,7mm AISI 201 50m Installation of cables, ventilation ducts, masts, poles, road signs; suspension of additional equipment for cable ducts, process piping, poles; packing for transport, bundling of steel and plastic pipes, installation of flexible pipe connections, and many others. Elements used in moderate corrosive environments. Interior architectural applications, elements used in air-conditioned rooms. Construction applications in moderate corrosive environments. Components operating at high temperature change gradient, exposed to strong oxidation at high temperatures. Applications for agriculture, transport applications. Technical characteristics: • Moderate mechanical strength • Resistant to oxidation at high temperatures • Resistance to low temperatures • Thermal expansion lower than austenitic grades • Smooth finish on all surfaces

BELT BUCKLE FOR STAINLESS STEEL BAND 18mm-201/304-20mm-304 (DTLF-BBSS-18MM-201/304) Fiber Optic Cable Line Fittings,Belt Buckle for Stainless Steel Band 18MM-201/304-20MM-304-(DTLF-BBSS18MM-201/304). Technical characteristics: • Model: DTLF-BBSS-18MM-201/304 • Brand: DAYTAI • Width:18mm or 20mm is optional. • Steel Materials: 201 or 304 is optional.

14


MICRODUCTS FOR FIBRE OPTICAL CABLES Fiber Guard pipes were designed for protection of fibre optical micro cables and for creating access networks. Specially designed smooth inner profile enables easy fiber installation in long sections. High flexible, it can be used in places not easily accessible. The use of pipes enables easy replacement of old optical fibre types to new ones. The single microducts can be prefabricated in bundles. FiberGuards are delivered on the wooden drums. Characteristics of material: Material is medium density polyethylene copolymer grade. The product has very good Elmendorf tear strength and Dart drop resistance, high termal resistance, resistans to most of chemical compaunds, good dielectric properites. The grade contains antioxidants and acid scavenger. Available accessories: The solution fibre-line. The plug-in connection system for sensitive optical fibres is manufactured without metal components and thus assures the reliable transmission of data free of disturbances. By virtue of the catch, the microduct conduits are connected in a doubly safe and durable manner. Synthetic clamping sleeves maintain the conduits in an unalterable position.

FIBERGUARD FG

FIBERGUARD FGG

Technical characteristics:

Technical characteristics:

• Inner profile: smooth

• Inner profile: grooved

• Coefficient of friction: 0,12

• Coefficient of friction: >0,12

• Internal pressure resistance: 15 bar

• Internal pressure resistance: 15 bar

• Material: polyethylene mod. (MDPE mod.)

• Material: polyethylene mod.

• Flammability: FG flammable FG-FR self-extinguishing FG-HFFR halogen free self-extinguishing

• Flammability: FGG flammable FGG-FR self-extinguishing FGG-HFFR halogen free self-extinguishing

AVAILABLE DIAMETERS Symbol

Inside diameter (mm)

Outside diameter (mm)

Wall thickness (mm)

5/3,5

3,5

5

0,75

7/3,5

3,5

7,0

1,75

7/5,5

5,5

7,0

0,75

10/6,0

6,0

10,0

2,0

10/8,0

0,8

10,0

1,0

12/8,0

0,8

12,0

2,0

12/10,0

0,10

12,0

1,0

14/10,0

0,10

14,0

2,0

14/12,0

0,12

14,0

1,0

16/12,0

0,12

16,0

2,0

15


Fiber Optic Splice Closures FIBER OPTIC SPLICE CLOSURE POLE-MOUNTED JOINT BOX TRACOM MDU B16 oval port, uncut port

The L5616 MDU B16 pole-mounted joint box has two main cable ports and 16 DROP subscriber cable ports. MDU B16 is a box-type design with 18 inlet/outlet ports. This type of a joint box is used to protect fiber optic cable strands and branching systems in overhead and wall-mounted installations. Quality polycarbonate (PC) housing is resistant to UV radiation, low (-40°C) and high (+ 60°C) temperatures and chemicals, which makes it suitable for overhead, ducting and buried cable installations. It is designed for simple and effective installation, while offering a proven fiber optic management system. All metallic parts of the joint box are made of corrosion-resistant materials. The box has a uncut type modular (bolt on) port. The module contains two oval type (18 mm) points of entry. Such design allows inserting the cable into the box without having to pull it through the port. A cassette with a maximum of 24 splices s and a panel for 16 SC simplex adapters is also provided. Technical characteristics: • Housing type: box • Height: 300 mm • Subscriber ports: 16 pcs. (size: 11 mm) • Main ports: 2 (size: 18 mm) • Splice capacity: 24 pcs. • Weight: 1.6 kg

FIBER OPTIC SPLICE CLOSURE - UP TO 144 FIBRES The fibre optic dome enclosure is suitable for protecting fibre cable splices in branching applications. Its wellengineered, injection-moulded outer body makes it impenetrable to the elements. It can protect splices and ensure reliability with usage in ambient temperatures from -40°C to 65°C. It can be placed in aerial, wall mounted or duct mounted locations. Rated to IP68. Comes with 2 splice trays capable of holding up to 24 splice protectors or mounting ruggedised splitter modules. Suitable for cable diameters up to 17.5mm, available with multihole inserts for multiple exit cables or sealant kit. Technical characteristics: • Holds up to 48 fibres • Easy to re-enter • Cable entry/exit, 5 round • Integrated pressure valve • Termination and splice kit and waterproof

Can be used in through, branch or mid-span splice locations Suitable for aerial, pole mounted, underground duct or direct burial applications.

16

• Indea for cable repair • RoHS complaint • Rated to IP68


FIBER OPTIC SPLICE CLOSURE TRACOM SC H2 (48J: 4XPO35)

Series of vertical fiber optic splice closures Tracom is equipped with a fully sealed heat-shrink ports of entry/exit. This type of splice closure is used to protect cable bundles of optical fiber cable and branching application. Material Polypropylene (PP) (in previous version it was: Polycarbonate (PC)) which creates the cover is made of high quality plastic, resistant to UV RAYS, low (-40°C) and high (+60°C) temperature, and chemicals, making it suitable for installation of overhead and to canalization and to ground. Designed to easy and simple installation. Fiber organization in fiber optic splice closures is easier because you can install fiber trays, which can be purchased separately, and allowing the customers to decide whether they need and in what quantity. All metal components of fiber optic splice closure are made of corrosion-resistant materials.

Tracom SC H2 (48J: 4xP035 is a cruising fiber optic splice closure, equipped with 6 ports of entry/exit. Flat and compact design of the fiber optic splice closure, enables it to be installed in places with limited space. Designed to easy and simple installation. Mechanical seal system ports using the supplied couplers rubber seals. Kit contains: - Fiber fusion Splice Protection Sleeves - Tube for the distribution fibers - Self-adhesive aluminium tape for cable protection during welding shrink tape - Sandpaper - Paper labels - Adhesive tape - Mounting screws - 2 mounting keys Technical characteristics: • Type: Box • Height: 323.00 mm • Weight: 3,0 kg • Splice tray (fibers): P035 (12) • Maximum capacity of fibers (trays): 48 (4) • Seal: Mechanical • Ports (Round): 2pcs. (20mm) 2pcs. (16mm) 2pcs. (13mm)