MMRCL Office Headquarters_Working Drawings_2021-22

Page 1

WORKI NGDRAWI NGS OFFI CEBUI LDI NG

CONTENTS LI NEOUTPLAN CENTRELI NEPLAN GROUNDFL OORARCHI TECTURALLAYOUT BASEMENTFL OORLAYOUT FI RSTFL OORARCHI TECTURALLAYOUT ROOFPLAN GROUNDFL OORSTRUCTURALLAYOUT FI RSTFL OORSTRUCTURALLAYOUT PLI NTHBEAM LAYOUT SECTI ON1 SECTI ON2 ELEVATI ON1 ELEVATI ON2 ELEVATI ON3 TOI LETDET AI L ST AI RCASEDET AI L

CHAI T ANYAAAGRAWAL 02

ARCHI TECTURALDET AI LS SCHEDULEANDBROCHURE


GENERAL NOTES

P

1) All dimensions are in 'millimeters' unless specified 2) The drawing is not to be scaled. The dimensions are strictly to be followed. 3) All levels are unfinished levels unless specified. 4) The contractor shall verify all on site dimensions including elevations prior to the commencement of work on site. 5) The contractor shall inform the architect and/or project engineer on site regarding any conditions/ modifications required to be done prior to the commencement of work. 6) The contractor shall coordinate and verify the work indicated on the drawings between the architectural and various trade drawings, including but not limited to structural, electrical, plumbing, fire protection and exterior enclosure systems. 7) All work shall conform to relevant BIS codes and shall be best practice of each trade. 8) Any discrepancy is to be brought to the notice of the architect/ consultant before commencement of the site. 9) All work is to be completed to the satisfaction of site engineer/ project manager and architects

0

ENTRY

1

2

66400

3

46960

0

0

SERVICE ENTRY/EXIT

0

ENTRY

20710

EXIT

20

0

508

AMPHITHEATRE

N 49798 E 10800

N 42700 E 19892

J

B

1900

5570

5570

N 41970 E 19210

N 39558 E 24586

D

N 39339 E 24381

F

N 39119 E 24177

H

N 38899 E 23973

K

N 38172 E 23293

6370

N 33830 E 27960

L

0

00

31

29

90 0

0

19

27

15150

259

0

35

20

18

11000

°

90

90 °

I

G

N 42920 E 20096

N 43360 E 20500

1000

42270

11490

N 43130 E 20300

300

A C E

PLINTH F.FL : +0.60 M 218 00

137°

N 41748 E 3304

0

M

12 0

42

S

137°

N 29324 E 9284

13

N 29324 E 8844

10270 10600 10920

10920

V

P

N 22542 E 17450

R

N 22323 E 17246

T

N 22104 E 17042

EXIT

N 21883 E 16841 0

U

30

9940

900

Q

N 29324 E 10165

300

N N 29324 E 9726

55

90°

EXIT

40

FIRST FL : +4.10 M

W

9210

10

N 29324 E 3304

65350

X

N 26340 E 3310

Y

REVISION TABLE

N 17520 E 12780

DATE

4660

4

REVISION

DESCRIPTION

35590

A' EN 14590 11230

40

205

70

00

9200

5

1930

N 7290 E 5610

0

A

ENTRY

9200

9 0

N ORIGIN (0,0) 0

0

E

30670

6

21710

7

R

8

KEY PLAN PROJECT NAME:

METRO HEAD OFFICE SHEET NUMBER:

SHEET TITLE:

GROUND FLOOR PLAN SCALE :

1

1 : 50 NORTH

NAME :

CHAITANYAA AGRAWAL

SEMESTER 6

T . Y . B.ARCH

ACADEMY OF ARCHITECTURE, MUMBAI

01

LINEOUT PLAN 1 : 200

SIGN AND STAMP

ROLL NO.

02


GENERAL NOTES

0

C1, C7

C6 0

C2

0

0

C3

0

C8

C12

0

C11

B B'

A

D E

C

C5, C10, C13

C4, C9

0

1) All dimensions are in 'millimeters' unless specified 2) The drawing is not to be scaled. The dimensions are strictly to be followed. 3) All levels are unfinished levels unless specified. 4) The contractor shall verify all on site dimensions including elevations prior to the commencement of work on site. 5) The contractor shall inform the architect and/or project engineer on site regarding any conditions/ modifications required to be done prior to the commencement of work. 6) The contractor shall coordinate and verify the work indicated on the drawings between the architectural and various trade drawings, including but not limited to structural, electrical, plumbing, fire protection and exterior enclosure systems. 7) All work shall conform to relevant BIS codes and shall be best practice of each trade. 8) Any discrepancy is to be brought to the notice of the architect/ consultant before commencement of the site. 9) All work is to be completed to the satisfaction of site engineer/ project manager and architects

0

0

F

H

G

5570

5340

6160

6370

0

C1

0

1 2 3

1 2 3

0

C2

0

C1

N 49320 E 11030

C2

1000 MM x 400 MM

N 45950 E 14210 7060

400 MM x 1000 MM

C3 , C4, C5

7060

0

3900

0

C3

N 43340 E 14580

C4

800 MM

N 33720 E 24920

C5

800 MM

800 MM

1470

1480

3690

N 38530 E 19750

3690

N 41280 E 9460

C6

0

0

4

10

5630

15460

10110

4

C6

10110

1000 MM x 400 MM

00

00

39

0

C7

0

C7

5 6 7

N 41280 E 3510 7200

0

78

00

0

C8

5 6 7

1000 MM x 400 MM

0

68

0

C9, C10

0

00

C8

29 39 00

00

N 34540 E 9910

C9

1000 MM x 400 MM

68

N 31120 E 12860

N 26240

C10 E 18110

800 MM

800 MM

REVISION TABLE DATE

0

DESCRIPTION

0

8

8

20 00

C11

REVISION

54

C11

80

N 29820 E 9910

1000 MM x 400 MM

0 81

80

27 57 10

70

0

P

30

ENTRY

2

9210

0

0

0

0

10560

EXIT

ENTRY

SERVICE ENTRY/EXIT

0

I

0

9

9

EXIT

0

C12, C13

N 49798 E 10800

EXIT

Y

N 17520 E 12780

4

A' NE 14590 11230

5

N 7290 E 5610

0

A

ENTRY

1000 MM x 400 MM

0

N ORIGIN (0,0)

E 0

C13

N 19350 E 11700

0

C12

N 26620 E 3890

6

R

1000 MM x 400 MM

KEY PLAN PROJECT NAME:

METRO HEAD OFFICE SHEET TITLE:

SHEET NUMBER:

A' NE 14590 11230 0

0 0

0

0

02

0

0

0

0

SCALE :

A

B B'

C

D E

F

G

H

1 : 50 NORTH

NAME :

CHAITANYAA AGRAWAL

SEMESTER 6

T . Y . B.ARCH

ACADEMY OF ARCHITECTURE, MUMBAI

02

CENTRE LINE PLAN 1 : 50

SIGN AND STAMP

ROLL NO.

02


GENERAL NOTES

0

0

0

0

0

0

0

0

B B'

A

D E

C

1) All dimensions are in 'millimeters' unless specified 2) The drawing is not to be scaled. The dimensions are strictly to be followed. 3) All levels are unfinished levels unless specified. 4) The contractor shall verify all on site dimensions including elevations prior to the commencement of work on site. 5) The contractor shall inform the architect and/or project engineer on site regarding any conditions/ modifications required to be done prior to the commencement of work. 6) The contractor shall coordinate and verify the work indicated on the drawings between the architectural and various trade drawings, including but not limited to structural, electrical, plumbing, fire protection and exterior enclosure systems. 7) All work shall conform to relevant BIS codes and shall be best practice of each trade. 8) Any discrepancy is to be brought to the notice of the architect/ consultant before commencement of the site. 9) All work is to be completed to the satisfaction of site engineer/ project manager and architects

0

F

H

G

5570

FL : +0.15 M FL : +0.30 M

5340 1300

FL : +0.45 M

6160 1790

570

6630

FL : +0.60 M

2000

0

0

1 2 3

C1 B1 300 MM x 600 MM 300 MM x 600 MM

1300

0

0

C2 7060

7060

0

FL : +0.375 M

B8

420

3900

0

1 2 3

BATHROOM SLAB SUNK BY 250 MM

C4

C3

C5

300 MM x 600 MM

700

B16

DP1

DP3

DP2

B2

SW 2

1300

1480

550

SW 1

300 MM x 600 MM

MMRCL OFFICE AREA 0

0

B7

14420

10110

10110

300 MM x 600 MM

M

SW

RECEPTION

3 0 MM BMM1x 60

M

0

5

0 30

0

30

11 M SW 1 0 M BM1x 60

10

SW

3

9

SW

M M

22

2000

M 0 3 60 Bx 0 30

0

21

SW

5 6 7

20 19

7200

0

12

17 1

15 2

14

0

3

30

M

39 00

7

SW

8 9

BMM5x 60

0 30

10

6

REVISION TABLE

11

REVISION

DESCRIPTION

0

1550

1350

00

C1

FL : +0.60 M

1

FL : +0.45 M

G. LIFT

8

FL : +0.30 M

BMM4x 6

BMM9x 60

0 30

0 81

7

00

FL : +0.15 M

M M

0

30

0 M M

SW

DATE

DP5

DP4

LIFT LOBBY

0 0 MM BMM1x 60

M M

0 30

0

20

8

2 0 MM BMM1x 60

0

5 6

0

C10 1800

M

4

12

1910

0

13

C9

C8

BMM6x 60

SW

4

5 6 7 0

2000

18 16

0 30

C7

0

4

SW

5630

4 0 MM B1x 60

M

M

420

C6

BATHROOM SLAB SUNK BY 250 MM

0 30

4

F.FL : +4.10 M

SW 13

G. LIFT 0 72

57 10

SW

8 00

30

10660 0

0

9

9

C13

C12

KEY PLAN PROJECT NAME:

METRO HEAD OFFICE SHEET NUMBER:

SHEET TITLE:

GROUND FLOOR PLAN 0

0 0

0

0

0

0

0

0

SCALE :

A

B B'

C

07

D E

F

G

H

1 : 50 NORTH

NAME :

CHAITANYAA AGRAWAL

SEMESTER 6

T . Y . B.ARCH

ACADEMY OF ARCHITECTURE, MUMBAI

07

STRUCTURAL LAYOUT GROUND FLOOR 1 : 50

SIGN AND STAMP

ROLL NO.

02


GENERAL NOTES

0

0

0

0

0

0

0

0

B B'

A

D E

C

5340 1300

0

F

H

G

6160 1790

570

1) All dimensions are in 'millimeters' unless specified 2) The drawing is not to be scaled. The dimensions are strictly to be followed. 3) All levels are unfinished levels unless specified. 4) The contractor shall verify all on site dimensions including elevations prior to the commencement of work on site. 5) The contractor shall inform the architect and/or project engineer on site regarding any conditions/ modifications required to be done prior to the commencement of work. 6) The contractor shall coordinate and verify the work indicated on the drawings between the architectural and various trade drawings, including but not limited to structural, electrical, plumbing, fire protection and exterior enclosure systems. 7) All work shall conform to relevant BIS codes and shall be best practice of each trade. 8) Any discrepancy is to be brought to the notice of the architect/ consultant before commencement of the site. 9) All work is to be completed to the satisfaction of site engineer/ project manager and architects

6630

2000

0

0

1 2 3

C1 B1 300 MM x 600 MM 300 MM x 600 MM

1300

0

0

C2 7060

7060

0

FL : +0.375 M

B8

420

3900

0

1 2 3

BATHROOM SLAB SUNK BY 250 MM

C4

C3

C5

300 MM x 600 MM

700

B16

DP1

DP3

DP2

B2

SW 2

1300

1480

550

SW 1

300 MM x 600 MM

MMRCL OFFICE AREA 0

0

B7

14420

10110

10110

300 MM x 600 MM

M

SW

RECEPTION

3 0 MM BMM1x 60

M

0

5

0 30

0

30

11 M SW 1 0 M BM1x 60

10

SW

3

9

SW

M M

22

2000

M 0 3 60 Bx 0 30

0

21

SW

5 6 7

4

SW

5630

4 0 MM B1x 60

M

M

420

C6

BATHROOM SLAB SUNK BY 250 MM

0 30

4

F.FL : +4.10 M

20 19

0

5 6 7 0

12

1 2

14

0

3

13

M

4

39

6

00

7

SW

9

BMM5x 60

0 30

10

6

REVISION TABLE

11

DATE

DP5

DP4

LIFT LOBBY

REVISION

DESCRIPTION

0

8

00

C1

20

0 0 MM BMM1x 60

M M

0 30

0

0

2 0 MM BMM1x 60

0

5

C10

C9

30

M

12

1800

0

C8

BMM6x 60

SW

4

15

8

8

2000

7200

17 16

0 30

C7

0

18

1

G. LIFT

7

M

0

M

30

0 M M

SW

BMM9x 60

0 30

0 81

M

M 0 4 60 Bx

SW 9

G. LIFT

57 10

SW

8

DP6

DP5 10660 0

0

9

9

C13

C12

KEY PLAN PROJECT NAME:

METRO HEAD OFFICE SHEET NUMBER:

SHEET TITLE:

GROUND FLOOR PLAN 0

0 0

0

0

0

0

0

0

SCALE :

A

B B'

C

10

D E

F

G

H

1 : 50 NORTH

NAME :

CHAITANYAA AGRAWAL

SEMESTER 6

T . Y . B.ARCH

ACADEMY OF ARCHITECTURE, MUMBAI

10

STRUCTURAL LAYOUT OFFICE FLOORS 1 : 50

SIGN AND STAMP

ROLL NO.

02


GENERAL NOTES 1) All dimensions are in 'millimeters' unless specified 2) The drawing is not to be scaled. The dimensions are strictly to be followed. 3) All levels are unfinished levels unless specified. 4) The contractor shall verify all on site dimensions including elevations prior to the commencement of work on site. 5) The contractor shall inform the architect and/or project engineer on site regarding any conditions/ modifications required to be done prior to the commencement of work. 6) The contractor shall coordinate and verify the work indicated on the drawings between the architectural and various trade drawings, including but not limited to structural, electrical, plumbing, fire protection and exterior enclosure systems. 7) All work shall conform to relevant BIS codes and shall be best practice of each trade. 8) Any discrepancy is to be brought to the notice of the architect/ consultant before commencement of the site. 9) All work is to be completed to the satisfaction of site engineer/ project manager and architects

5340

PB1

300 MM x 600 MM

C2

C1 PB27

PB18

300 MM x 600 MM

300 MM x 600 MM

PB2

PB4

PB3

300 MM x 600 MM

300 MM x 600 MM

300 MM x 600 MM

11

FIRE EXIT

10

C3

UP

9

C4

8

C5

7 6 5

SW 1

4 3

300 MM x 600 MM

1

12

PB28

PB26

300 MM x 600 MM

2

PB5

300 MM x 600 MM

13 14 15 16 17 18

SW 2

19

PB31

300 MM x 600 MM

PB25

M

50600 M PBMM x

0 30

C6

300 MM x 600 MM

20 21 22

10600 M P0 BMM x

M

47600 M P0BMM x

30

30

M

51600 M P0 BMM x

30

16100 M P0 BMM x

M

M

30

0

46100 MM PMBM x

30

C8

BASEMENT PARKING

48600 M P0 BMM x

30

4

0

7

C

SW

C9

M

16200 M P0 MBM x

C10

49600 M P0 BMM x

30

0

46200 MM PMBM x

30

SW

6

F.FL : -4.00 M

PB6

300 MM x 600 MM

M

30

M

0

46500 MM PMBM x

30

SW

M

0 30

PB32

300 MM x 600 MM

PB30

300 MM x 600 MM

1

C1

13600 M PBMM x

0

7

46600 MM PMBM x

30

SW

8

0

46300 MM PMBM x

30

C1 C13

C12

0

0

36900 MM PMBM x

30

46000 MM PMBM x

30

PB7

300 MM x 600 MM

16600 MM P0 BMM x

REVISION TABLE DATE

30

0

46400 MM PMBM x

30

REVISION

DESCRIPTION

M 23600 M PBM x

C14

0

M

30 0

36700 MM PMBM x

30

1x5600 M P0BMM

M

30

0

46000 MM PMBM x

30

C15

C16

26200 M P0 BMM x

M

30

0

M

0

36400 MM PMBM x

30

36800 MM PMBM x

30

26000 M P0 BMM x

30

C17 PB8

300 MM x 600 MM

1x4600 M P0BMM

C18

M

19600 MM P0 BMM x

30

30

C19

26100 M P0 BMM x

M

30

M

0

C20

0

36500 MM PMBM x

30

36300 MM PMBM x

30

16800 M P0 BMM x

30

PB9

PB29

300 MM x 600 MM

300 MM x 600 MM

C21

PB24

36600 MM P0 MBM x

30

30

M

300 MM x 600 MM

C22 16700 M P0 BMM x

KEY PLAN PROJECT NAME:

METRO HEAD OFFICE SHEET NUMBER:

SHEET TITLE:

GROUND FLOOR PLAN SCALE :

11

1:200 NORTH

NAME :

CHAITANYAA AGRAWAL

SEMESTER 6

11

PLINTH BEAM PLAN 1:200

T . Y . B.ARCH

ACADEMY OF ARCHITECTURE, MUMBAI

SIGN AND STAMP

ROLL NO.

02


GENERAL NOTES

0

0

0

0

0

0

0

0

B B'

A

D E

C

1) All dimensions are in 'millimeters' unless specified 2) The drawing is not to be scaled. The dimensions are strictly to be followed. 3) All levels are unfinished levels unless specified. 4) The contractor shall verify all on site dimensions including elevations prior to the commencement of work on site. 5) The contractor shall inform the architect and/or project engineer on site regarding any conditions/ modifications required to be done prior to the commencement of work. 6) The contractor shall coordinate and verify the work indicated on the drawings between the architectural and various trade drawings, including but not limited to structural, electrical, plumbing, fire protection and exterior enclosure systems. 7) All work shall conform to relevant BIS codes and shall be best practice of each trade. 8) Any discrepancy is to be brought to the notice of the architect/ consultant before commencement of the site. 9) All work is to be completed to the satisfaction of site engineer/ project manager and architects

0

F

H

G

5570

FL : +0.15 M FL : +0.30 M

5340 1300

FL : +0.45 M

6160 1790

570

6630

FL : +0.60 M

2000

580

1780

820

0

0

1 2 3

C1

1 2 3

D1

0

0

2210

4890 TOILET FFL = +0.620 M UFL = +0.375 M

3440

420

0

3900

18090

3860

2300

1300

C2 770

D4

7060

7060

0

D2 1690

C4

C3

C5

D5

3250

D6

700

1480

550

2840

1410

D3

1820

MMRCL OFFICE AREA

18090

27

2600

30

FFL = +1.79 M UFL = +1.75 M 90

35

D12 L.V

2370

D14

0

0

H.V 0 88

22

70

24 80

5 6 7

30 26

RECEPTION 0 87 10

C7

D13

30

2210

30

D11 F.F 0 0 14

PASSAGE

21

FFL = +0.640 M UFL = +0.60 M

20 19

AIR HANDLING UNIT

D15

7200

18 17 16 1

15 2

14 3

13 4

12

8

1800

90

00

33

7

50

C10

22

39

6

C9

C8

5

0

9 17

0

40

0 62

35

30

29 2

0

9 11

1650

70

90

10

52

10

0 80

FFL = +1.79 M UFL = +1.75 M

5 6 7 0

2000

0

4

2000

5630

90

2360 TOILET

FFL = +0.640 M UFL = +0.60 M

10110

420

16

4

C6

D10

D9

0

14420

0

10110

D8

1830

1100

1380

1500

1300

D7

D16

REVISION TABLE

5970 DATE

50

32

REVISION

70

16

10

0

D17 1550

20

1350

00

FL : +0.60 M

17

SW 2

60

10

C11

G. LIFT

26

1910

8

00

W1

10

SW 1

10

LIFT LOBBY FFL = +0.640 M UFL = +0.60 M

0

DESCRIPTION

FL : +0.45 M

8

FL : +0.30 M

0 81

FL : +0.15 M

00

10

W2 10920

80

19

0

SW 5

80

G. LIFT 0 72

57 10 00

30

SW 4 10660 0

0

9

9

C13

C12

KEY PLAN PROJECT NAME:

METRO HEAD OFFICE SHEET NUMBER:

SHEET TITLE:

GROUND FLOOR PLAN 0

0 0

0

0

0

0

0

0

SCALE :

A

B B'

C

03

D E

F

G

H

1 : 50 NORTH

NAME :

CHAITANYAA AGRAWAL

SEMESTER 6

T . Y . B.ARCH

ACADEMY OF ARCHITECTURE, MUMBAI

03

ARCHITECTURAL LAYOUT GROUND FLOOR 1 : 50

SIGN AND STAMP

ROLL NO.

02


GENERAL NOTES 1) All dimensions are in 'millimeters' unless specified 2) The drawing is not to be scaled. The dimensions are strictly to be followed. 3) All levels are unfinished levels unless specified. 4) The contractor shall verify all on site dimensions including elevations prior to the commencement of work on site. 5) The contractor shall inform the architect and/or project engineer on site regarding any conditions/ modifications required to be done prior to the commencement of work. 6) The contractor shall coordinate and verify the work indicated on the drawings between the architectural and various trade drawings, including but not limited to structural, electrical, plumbing, fire protection and exterior enclosure systems. 7) All work shall conform to relevant BIS codes and shall be best practice of each trade. 8) Any discrepancy is to be brought to the notice of the architect/ consultant before commencement of the site. 9) All work is to be completed to the satisfaction of site engineer/ project manager and architects

11

FIRE EXIT

10

UP

9 8 7 6 5 4 3 2 1

12 13 14 15 16 17 18 19 20 21 22

0

BASEMENT PARKING F.FL : -4.00 M

26 60

46

40

C2

C1

REVISION TABLE DATE

REVISION

DESCRIPTION

0

6 95

5500

C3 C4

C5

00 12

C6

00 24

0

SEWAGE TREATMENT PLANT

BMS ROOM

C7

00 25

80

31

C8 0

0

SUMP 0

ELECTRICAL ROOM PUMP ROOM

5500

0

C9

AHU PANEL ROOM, FAN ROOM C11 C10

FLUSHING TANK

DOMESTIC WATER TANK

R.W TANK

KEY PLAN PROJECT NAME:

METRO HEAD OFFICE SHEET NUMBER:

SHEET TITLE:

GROUND FLOOR PLAN

04

SCALE : NORTH NAME :

CHAITANYAA AGRAWAL

SEMESTER 6

04

BASEMENT PLAN 1 : 200

T . Y . B.ARCH

ACADEMY OF ARCHITECTURE, MUMBAI

SIGN AND STAMP

ROLL NO.

02


GENERAL NOTES

0

0

0

0

0

0

0

0

B B'

A

D E

C

5340 1300

0

F

H

G

6160 1790

570

1) All dimensions are in 'millimeters' unless specified 2) The drawing is not to be scaled. The dimensions are strictly to be followed. 3) All levels are unfinished levels unless specified. 4) The contractor shall verify all on site dimensions including elevations prior to the commencement of work on site. 5) The contractor shall inform the architect and/or project engineer on site regarding any conditions/ modifications required to be done prior to the commencement of work. 6) The contractor shall coordinate and verify the work indicated on the drawings between the architectural and various trade drawings, including but not limited to structural, electrical, plumbing, fire protection and exterior enclosure systems. 7) All work shall conform to relevant BIS codes and shall be best practice of each trade. 8) Any discrepancy is to be brought to the notice of the architect/ consultant before commencement of the site. 9) All work is to be completed to the satisfaction of site engineer/ project manager and architects

6630

2000

2000

0

0

1 2 3

C1

1 2 3

0

0

2210

4890

TOILET FFL = +0.620 M UFL = +0.375 M

3440

420

0

3900

18090

3860

2300

1300

C2 770

D4

7060

7060

0

D2 1690

C4

C3

C5

D5

3250

700

1480

550

2840

1410

D3

1820

D6

2360

90

TOILET 5630

2500

27

30 90

35

2370

D14

0

0

H.V 0 88

22

70

24

30 26

RECEPTION 0 87 10

C7

D13

30

D12 L.V

30

D11 F.F 0 0 14

2210

80

5 6 7

4

FFL = +1.79 M UFL = +1.75 M

PASSAGE

21

FFL = +0.640 M UFL = +0.60 M

20 19

AIR HANDLING UNIT

D15

7200

18 17 16 1

15 2

14 3

13

C8

4

12

0

40

0 62

35

C9

C10

5

0

39

9 17

6

00

33

7

50 23

8

REVISION TABLE

10

90

10

52

10

9

70

11

D15

0 80

FFL = +1.79 M UFL = +1.75 M

1800

30

29 2

0

5 6 7 0

2000

0

FFL = +0.640 M UFL = +0.60 M

2000

420

C6

D10

16

4

0

10110

D9

MMRCL OFFICE AREA

14420

18090

0

10110

D8

1830

1100

1480

1500

1300

D7

DATE

50

32

REVISION

0

70

00 17

SW 2

2000

20

8

00

W1

10

SW 1

10

LIFT LOBBY FFL = +0.640 M UFL = +0.60 M

0

DESCRIPTION

10

C11

8

G. LIFT 0 81

80

2000

00

10

W2

0

SW 5

G. LIFT

57

2000

10

SW 4 10660 0

1870

0

9

C13

C12 2000

2000

9

2000

KEY PLAN PROJECT NAME:

METRO HEAD OFFICE SHEET TITLE:

SHEET NUMBER:

FIRST FLOOR PLAN 0

0 0

0

0

0

0

0

0

SCALE :

A

B B'

C

08

D E

F

G

H

1 : 50 NORTH

NAME :

CHAITANYAA AGRAWAL

SEMESTER 6

T . Y . B.ARCH

ACADEMY OF ARCHITECTURE, MUMBAI

08

ARCHITECTURAL LAYOUT OFFICE FLOORS 1 : 50

SIGN AND STAMP

ROLL NO.

02


GENERAL NOTES 1) All dimensions are in 'millimeters' unless specified 2) The drawing is not to be scaled. The dimensions are strictly to be followed. 3) All levels are unfinished levels unless specified. 4) The contractor shall verify all on site dimensions including elevations prior to the commencement of work on site. 5) The contractor shall inform the architect and/or project engineer on site regarding any conditions/ modifications required to be done prior to the commencement of work. 6) The contractor shall coordinate and verify the work indicated on the drawings between the architectural and various trade drawings, including but not limited to structural, electrical, plumbing, fire protection and exterior enclosure systems. 7) All work shall conform to relevant BIS codes and shall be best practice of each trade. 8) Any discrepancy is to be brought to the notice of the architect/ consultant before commencement of the site. 9) All work is to be completed to the satisfaction of site engineer/ project manager and architects

5150 1790

570

2000

420

3900

1300

1300

8130

8750

1470

700 420

14420

1300

1480

550

3690

5630

8690

8130

50

17

37

2000

0 45

F.F SHAFT

90

50

21

F.F TANK

85 2000

0 7950

DOMESTIC

FLUSHING

ROOF LEVEL 53

1800

00

80

39

FFL : +36,015 M

OVER HEAD TANK F.FL : +4.10 M

68

00 REVISION TABLE

00

20

DATE

2530

REVISION

DESCRIPTION

8130

81 0 6200

10

57 00

20 14 10

2000

2000

2000

KEY PLAN PROJECT NAME:

METRO HEAD OFFICE SHEET TITLE:

SHEET NUMBER:

ROOF PLAN

SCALE :

06

1 : 50 NORTH

NAME :

CHAITANYAA AGRAWAL

SEMESTER 6

T . Y . B.ARCH

ACADEMY OF ARCHITECTURE, MUMBAI

06

ROOF PLAN 1 : 50

SIGN AND STAMP

ROLL NO.

02


GENERAL NOTES 1) All dimensions are in 'millimeters' unless specified 2) The drawing is not to be scaled. The dimensions are strictly to be followed. 3) All levels are unfinished levels unless specified. 4) The contractor shall verify all on site dimensions including elevations prior to the commencement of work on site. 5) The contractor shall inform the architect and/or project engineer on site regarding any conditions/ modifications required to be done prior to the commencement of work. 6) The contractor shall coordinate and verify the work indicated on the drawings between the architectural and various trade drawings, including but not limited to structural, electrical, plumbing, fire protection and exterior enclosure systems. 7) All work shall conform to relevant BIS codes and shall be best practice of each trade. 8) Any discrepancy is to be brought to the notice of the architect/ consultant before commencement of the site. 9) All work is to be completed to the satisfaction of site engineer/ project manager and architects

2250

RCC OVER HEAD TANK 1500 MM DEEP

OHT

OHT 20 MM THK CHINA MOSIAC 25 MM THK PCC 100 MM THK BBC

2250

3 MM THK WATERPROOFING

STAIRCASE MUMTY

CURTAIN GLAZING CONTINUED AS RAILING 1800 MM HIGH

TERRACE FLOOR LEVEL

600

1550

D15

+34.34M LVL

3160 2100

RCC BEAM (300MM X 400 MM) 200 MM THK BRICK WALL

2900

1950

25 MM THK NEERU FINISH PLASTER WITH WHITE PAINT

D6

D2

OFFICE AREA NINTH FLOOR LEVEL +31M LVL

3300 2100

2900

1950

FOLDED RCC STAIRCASE 150 MM THK

D8

600

1550

900

D15

D8

D6

D2

OFFICE AREA EIGHTH FLOOR LEVEL +27.50M LVL

600

1550

900

D15

3300 2100

2900

1950

ACP CLADDING FROM GF TO TERRACE

900

D15 D6

+24M LVL

3300

2900 900

D15 1550

OFFICE AREA SEVENTH FLOOR LEVEL

1300 100

SKIRTING

D2

600

1550

20 MM THK FLOOR FINISH VITRIFIED TILE 20 MM THK SCREEDING

D8

D8

D6

D2

OFFICE AREA SERVICE FLOOR LEVEL

2400

1400

+20.50M LVL

D15 D6

D2

SERVICE FLOOR FIFTH FLOOR LEVEL +18.10M LVL

2100

1100

2900

3300

850

600

1550

D8

D8

D6

D2

OFFICE AREA FOURTH FLOOR LEVEL +14.60M LVL

600

1550

900

D15

850

REVISION TABLE 3240

2900

D15

900

1100

D8

D6

D2

REVISION

DESCRIPTION

OFFICE AREA THIRD FLOOR LEVEL +11.10M LVL

2100

1100

2900

3300

850

600

1550

DATE

D8

D6

D2

OFFICE AREA SECOND FLOOR LEVEL +7.60M LVL

2100

1100

2900

3300

850

600

1550

900

D15

D8

D6

D2

OFFICE AREA FIRST FLOOR LEVEL +4.10M LVL

2100

3300

850

600

1550

900

D15

D8

D6

D2

OFFICE AREA

A'

PLINTH LEVEL B'

900

1750

D15

+0.60M LVL

150 MM THK PCC 230 MM THK RUBBLE SOLING MURUM

22 21 20 19 18 17 16 1

15 2

14

C10

3

13 4

12

5 6 7 8 9 10 11

A

150 MM THK PCC 230 MM THK RUBBLE SOLING

B

MURUM

PROJECT NAME:

SECTION A-A'

METRO HEAD OFFICE SHEET NUMBER:

SHEET TITLE:

ARCHITECTURAL DETAIL SCALE :

12

1 : 100 NORTH

NAME :

CHAITANYAA AGRAWAL

SEMESTER 6

T . Y . B.ARCH

ACADEMY OF ARCHITECTURE, MUMBAI

12

ARCHITECTURAL SECTION 1 : 100

SIGN AND STAMP

ROLL NO.

02


GENERAL NOTES 1) All dimensions are in 'millimeters' unless specified 2) The drawing is not to be scaled. The dimensions are strictly to be followed. 3) All levels are unfinished levels unless specified. 4) The contractor shall verify all on site dimensions including elevations prior to the commencement of work on site. 5) The contractor shall inform the architect and/or project engineer on site regarding any conditions/ modifications required to be done prior to the commencement of work. 6) The contractor shall coordinate and verify the work indicated on the drawings between the architectural and various trade drawings, including but not limited to structural, electrical, plumbing, fire protection and exterior enclosure systems. 7) All work shall conform to relevant BIS codes and shall be best practice of each trade. 8) Any discrepancy is to be brought to the notice of the architect/ consultant before commencement of the site. 9) All work is to be completed to the satisfaction of site engineer/ project manager and architects

20 MM THK CHINA MOSIAC 25 MM THK PCC 100 MM THK BBC 3 MM THK WATERPROOFING

20 MM THK CHINA MOSIAC 25 MM THK PCC

25 MM THICK PLASTER

100 MM THK BBC

LIFT MACHINE ROOM

3 MM THK WATERPROOFING

3170

RCC OVER HEAD TANK 1500 MM DEEP

TERRACE TERRACE FLOOR LEVEL

3160

20 MM THK SCREEDING 260

840

2080

1200 880

W1

20 MM THK VITRIFIED FLOOR TILE

OFFICE AREA

D15

3500

3300

3310

OFFICE AREA 260

W1

D15

840

880

2080

1200

2900

200 MM THK BRICK WALL

2M X 3.5M CURTAIN WALL SYSTEM

3160

LIFT LOBBY

820

1270

25 MM THK NEERU FINISH PLASTER WITH WHITE PAINT

2080

OFFICE AREA 260

840 1650

SERVICE FLOOR

2400

REFUGE AREA

260

360

700

D15

2020

750

650 1200

W1

3500

3160

3300

820

OFFICE AREA 260

880

W1

D15

840

2080

1200

1270

LIFT LOBBY

3500

3300

820

3160

OFFICE AREA 260

W1

D15

840

880

2080

1200

1270

600 2900

LIFT LOBBY

3500

3160 2080

OFFICE AREA 260

W1

D15

840

880

3300

820

1270 1200

2900

LIFT LOBBY

3500

3160 2080

260

W1

REVISION TABLE

OFFICE AREA

D15

840

880

3300

820

LIFT LOBBY

1200

1270

600 2900

THIRD FLOOR LEVEL +11.10M LVL

SECOND FLOOR LEVEL

DATE

REVISION

DESCRIPTION

+7.60M LVL

3500

3160 2080

260

W1

OFFICE AREA

D15

840

880

3300

820

LIFT LOBBY

1200

1270

600 2900

FOURTH FLOOR LEVEL +14.60M LVL

FIRST FLOOR LEVEL +4.10M LVL

2080

3500

3300

1210

20 MM THK SCREEDING D16

PLINTH LEVEL +0.60M LVL

4000

600

840

880

20 MM THK VITRIFIED FLOOR TILE

600

W1

RECEPTION

D15

2090

3160

820

LIFT LOBBY

1200

1270

600 2900

3500 4000

400 MM THK SHEAR WALL

FIFTH FLOOR LEVEL +18.10M LVL

600

20 MM THK FLOOR FINISH VITRIFIED TILE 20 MM THK SCREEDING

SERVICE FLOOR LEVEL +20.50M LVL

600 2900

CURTAIN GLAZING FROM GF TO TERRACE

SEVENTH FLOOR LEVEL +24M LVL

2060

880

W1

D15

3500

3160

3300

820

1270

LIFT LOBBY

1200

2900 1800

600

ACP CLADDING FROM GF TO TERRACE (3M X 1.3M)

EIGHTH FLOOR LEVEL +27.50M LVL

600

RCC BEAM (300MM X 600 MM)

NINTH FLOOR LEVEL +31M LVL

600

2150

3300

RAILING 1800 MM HIGH

3500

LIFT LOBBY

+34.34M LVL

820

1270

25 MM THICK PLASTER

RAMP 2040

BASEMENT

SPACE BELOW RAMP FILLED WITH SOIL

500 MM THK RAFT

230 MM THK RUBBLE SOLING

A'

1800

150 MM THK PCC

B'

MURUM

22 21 20 19 18 17 16 15

1 2

14

C10

3

13 4

12

5 6 7 8 9 10 11

A

B

KEY PLAN

SECTION B-B'

PROJECT NAME:

METRO HEAD OFFICE SHEET TITLE:

SHEET NUMBER:

ROOF PLAN

SCALE :

13

1 : 100 NORTH

NAME :

CHAITANYAA AGRAWAL

SEMESTER 6

T . Y . B.ARCH

ACADEMY OF ARCHITECTURE, MUMBAI

SIGN AND STAMP

13

ARCHITECTURAL SECTION 1 : 100

ROLL NO.

02


GENERAL NOTES

CURTAIN GLAZING FROM GF TO TERRACE

1) All dimensions are in 'millimeters' unless specified 2) The drawing is not to be scaled. The dimensions are strictly to be followed. 3) All levels are unfinished levels unless specified. 4) The contractor shall verify all on site dimensions including elevations prior to the commencement of work on site. 5) The contractor shall inform the architect and/or project engineer on site regarding any conditions/ modifications required to be done prior to the commencement of work. 6) The contractor shall coordinate and verify the work indicated on the drawings between the architectural and various trade drawings, including but not limited to structural, electrical, plumbing, fire protection and exterior enclosure systems. 7) All work shall conform to relevant BIS codes and shall be best practice of each trade. 8) Any discrepancy is to be brought to the notice of the architect/ consultant before commencement of the site. 9) All work is to be completed to the satisfaction of site engineer/ project manager and architects

TERRACE FLOOR LEVEL +34.34M LVL

NINTH FLOOR LEVEL +31M LVL

EIGHTH FLOOR LEVEL +27.50M LVL

SEVENTH FLOOR LEVEL +24M LVL

SERVICE FLOOR LEVEL +20.50M LVL

FIFTH FLOOR LEVEL +18.10M LVL

FOURTH FLOOR LEVEL +14.60M LVL

REVISION TABLE

THIRD FLOOR LEVEL

DATE

REVISION

+11.10M LVL

DESCRIPTION

CURTAIN GLAZING FROM GF TO TERRACE 2000 MM X 3500 MM

SECOND FLOOR LEVEL +7.60M LVL

ACP CLADDING 1300MM X 1750MM

FIRST FLOOR LEVEL +4.10M LVL

40 MM THICK GLASS SHUTTERS SINGLE PANELLED DOOR AUTOMATED SLIDING DOOR

D16

W2

PLINTH LEVEL +0.60M LVL

ELEVATION A-A' 22 21 20 19 18 17 16 15

1 2

14 3

13

C10

4

12

5 6 7 8 9 10 11

A

A'

KEY PLAN PROJECT NAME:

METRO HEAD OFFICE SHEET TITLE:

SHEET NUMBER:

ROOF PLAN

SCALE :

14

1 : 100 NORTH

NAME :

CHAITANYAA AGRAWAL

SEMESTER 6

T . Y . B.ARCH

ACADEMY OF ARCHITECTURE, MUMBAI

SIGN AND STAMP

14

ELEVATION 1 : 100

ROLL NO.

02


ACP CLADDING FROM GROUND FLOOR TO TERRACE

GENERAL NOTES 1) All dimensions are in 'millimeters' unless specified 2) The drawing is not to be scaled. The dimensions are strictly to be followed. 3) All levels are unfinished levels unless specified. 4) The contractor shall verify all on site dimensions including elevations prior to the commencement of work on site. 5) The contractor shall inform the architect and/or project engineer on site regarding any conditions/ modifications required to be done prior to the commencement of work. 6) The contractor shall coordinate and verify the work indicated on the drawings between the architectural and various trade drawings, including but not limited to structural, electrical, plumbing, fire protection and exterior enclosure systems. 7) All work shall conform to relevant BIS codes and shall be best practice of each trade. 8) Any discrepancy is to be brought to the notice of the architect/ consultant before commencement of the site. 9) All work is to be completed to the satisfaction of site engineer/ project manager and architects

TERRACE FLOOR LEVEL +34.34M LVL

NINTH FLOOR LEVEL +31M LVL

EIGHTH FLOOR LEVEL +27.50M LVL

SEVENTH FLOOR LEVEL +24M LVL

SERVICE FLOOR LEVEL +20.50M LVL

FIFTH FLOOR LEVEL +18.10M LVL

FOURTH FLOOR LEVEL +14.60M LVL

THIRD FLOOR LEVEL +11.10M LVL

SECOND FLOOR LEVEL +7.60M LVL

ACP CLADDING 1300MM X 1750MM

FIRST FLOOR LEVEL ACP CLADDING FROM GROUND FLOOR TO TERRACE

+4.10M LVL

W1

PLINTH LEVEL +0.60M LVL

ELEVATION C-C'

TERRACE FLOOR LEVEL +34.34M LVL

NINTH FLOOR LEVEL +31M LVL

REVISION TABLE DATE

REVISION

DESCRIPTION

EIGHTH FLOOR LEVEL +27.50M LVL

SEVENTH FLOOR LEVEL +24M LVL

SERVICE FLOOR LEVEL +20.50M LVL

FIFTH FLOOR LEVEL +18.10M LVL

C

FOURTH FLOOR LEVEL +14.60M LVL 22 21 20 19 18 17 16

B

15

1 2

14

C10

3

13 4

12 5 6 7 8 9 10 11

B'

THIRD FLOOR LEVEL C'

+11.10M LVL

KEY PLAN PROJECT NAME:

SECOND FLOOR LEVEL +7.60M LVL

METRO HEAD OFFICE

WINDOW

SHEET TITLE:

SHEET NUMBER:

ROOF PLAN

14

FIRST FLOOR LEVEL +4.10M LVL

ACP CLADDING 1300MM X 1750MM

SCALE :

1 : 100 NORTH

W1

NAME :

PLINTH LEVEL +0.60M LVL

CHAITANYAA AGRAWAL

SEMESTER 6

ACADEMY OF ARCHITECTURE, MUMBAI

SIGN AND STAMP

14

ELEVATION 1 : 100

ELEVATION B-B'

T . Y . B.ARCH

ROLL NO.

02


CURTAIN GLAZING FROM GF TO TERRACE

GENERAL NOTES

CURTAIN GLAZING FROM GF TO TERRACE 2000 MM X 3500 MM

1) All dimensions are in 'millimeters' unless specified 2) The drawing is not to be scaled. The dimensions are strictly to be followed. 3) All levels are unfinished levels unless specified. 4) The contractor shall verify all on site dimensions including elevations prior to the commencement of work on site. 5) The contractor shall inform the architect and/or project engineer on site regarding any conditions/ modifications required to be done prior to the commencement of work. 6) The contractor shall coordinate and verify the work indicated on the drawings between the architectural and various trade drawings, including but not limited to structural, electrical, plumbing, fire protection and exterior enclosure systems. 7) All work shall conform to relevant BIS codes and shall be best practice of each trade. 8) Any discrepancy is to be brought to the notice of the architect/ consultant before commencement of the site. 9) All work is to be completed to the satisfaction of site engineer/ project manager and architects

TERRACE FLOOR LEVEL +34.34M LVL

NINTH FLOOR LEVEL +31M LVL

EIGHTH FLOOR LEVEL +27.50M LVL

SEVENTH FLOOR LEVEL +24M LVL

SERVICE FLOOR LEVEL +20.50M LVL

FIFTH FLOOR LEVEL +18.10M LVL

FOURTH FLOOR LEVEL +14.60M LVL

THIRD FLOOR LEVEL +11.10M LVL

SECOND FLOOR LEVEL +7.60M LVL

FIRST FLOOR LEVEL

OVER HEAD TANK

+4.10M LVL

STAIRCASE MUMTY

ACP CLADDING 1300MM X 1750MM

CANOPY

COLUMN WINDOW

PLINTH LEVEL

TERRACE FLOOR LEVEL CURTAIN GLAZING FROM GF TO TERRACE

+0.60M LVL

ELEVATION D-D'

+34.34M LVL

NINTH FLOOR LEVEL +31M LVL

REVISION TABLE DATE

REVISION

DESCRIPTION

EIGHTH FLOOR LEVEL +27.50M LVL

SEVENTH FLOOR LEVEL +24M LVL

SERVICE FLOOR LEVEL +20.50M LVL

FIFTH FLOOR LEVEL +18.10M LVL

E'

D'

E

FOURTH FLOOR LEVEL +14.60M LVL 22 21 20 19 18 17 16 1

15 2

14

C10

3

13 4

12

5 6 7 8 9 10 11

THIRD FLOOR LEVEL D

+11.10M LVL

KEY PLAN

CURTAIN GLAZING FROM GF TO TERRACE 2000 MM X 3500 MM

SECOND FLOOR LEVEL +7.60M LVL

PROJECT NAME:

METRO HEAD OFFICE SHEET TITLE:

SHEET NUMBER:

ROOF PLAN

15

FIRST FLOOR LEVEL ACP CLADDING 1300MM X 1750MM

+4.10M LVL

SCALE :

1 : 100 NORTH

40 MM THICK GLASS SHUTTERS SINGLE PANELLED DOOR AUTOMATED SLIDING DOOR

NAME :

CHAITANYAA AGRAWAL

PLINTH LEVEL +0.60M LVL

SEMESTER 6

T . Y . B.ARCH

ACADEMY OF ARCHITECTURE, MUMBAI

SIGN AND STAMP

15

ELEVATION 1 : 100

ELEVATION E-E'

ROLL NO.

02


600

GENERAL NOTES

800

4710

150MM THK RCC SUNK SLAB

150MM THK RCC SUNK SLAB

RCC BEAM 300X600MM

RCC BEAM 300X600MM EXHAUST FAN ACP DRY CLADDING

25 MM THK NEERU PLASTER FINISH 150 MM THK BRICK WALL

HER

HER

DISABLE

1500

1270

1150

1000

230 MM THK BRICK WALL

C

GRANITE COUNTERTOP

3500 F

F

W

WASH BASIN 12MM CERAMIC TILE

600

D

W

HF

HF

WC

WC

HF WC

12MM CERAMIC TILE

25 MM SCREEDING BRICK BAT COBA

25 MM SCREEDING BRICK BAT COBA

PLINTH BEAM 400X600MM 150 MM PCC 230 MM RUBBER SOLING

PLINTH BEAM 400X600MM 150 MM PCC 230 MM RUBBER SOLING

BACKFILLING

BACKFILLING

SECTION B-B'

SECTION A-A'

C

FLUSH TANK STAINLESS STEEL GRIP HANDLE HEALTH FAUCET

BT

450

890

2300

300X300MM DADO TILE MIRROR

F W

150 MM THK BRICK INTERNAL WALL 25 MM THK PARTITION

2200

BT

2200

2080

2200 1800

BT

M

300X300MM DADO TILE BIB TAP MIRROR

M

700 790

3500 2900

2100

1) All dimensions are in 'millimeters' unless specified 2) The drawing is not to be scaled. The dimensions are strictly to be followed. 3) All levels are unfinished levels unless specified. 4) The contractor shall verify all on site dimensions including elevations prior to the commencement of work on site. 5) The contractor shall inform the architect and/or project engineer on site regarding any conditions/ modifications required to be done prior to the commencement of work. 6) The contractor shall coordinate and verify the work indicated on the drawings between the architectural and various trade drawings, including but not limited to structural, electrical, plumbing, fire protection and exterior enclosure systems. 7) All work shall conform to relevant BIS codes and shall be best practice of each trade. 8) Any discrepancy is to be brought to the notice of the architect/ consultant before commencement of the site. 9) All work is to be completed to the satisfaction of site engineer/ project manager and architects

5340 570

9560 600

1300

150MM THK RCC SUNK SLAB

3880

WC

URINAL WATER CLOSET 12MM CERAMIC TILE 25 MM SCREEDING BRICK BAT COBA

2840

600

WC

25 MM THK PARTITION

F

850

950

U

950 450

1410

N

PLINTH BEAM 400X600MM 150 MM PCC 230 MM RUBBER SOLING

REVISION TABLE DATE

REVISION

DESCRIPTION

BACKFILLING

3250

D6

700

1480

550

N

25 MM THK NEERU PLASTER FINISH 150 MM THK BRICK WALL

1440

1100

F

B

HER

300X300MM DADO TILE

U

B'

RCC BEAM 300X600MM

2200

1690

2900

3440

420

D3

A'

3500

2210

3860 4890 TOILET FFL = +0.620 M UFL = +0.375 M D4 D5

PLUMBING SHAFT

1450

2300

1300

HIS

A 3900

3600

SECTION C-C'

1100

1380

1500

1300

N

LEGEND 300X300MM CERAMIC DADO TILES

420

600X600MM 10MM THICK CERAMIC FLOOR TILES 20MM THICK CEMENT MORTAR

D9

2360

D10

SYMBOL

C

ITEM

COUNTERTOP

25MM THICK GRANITE FINISHED COUNTERTOP

WASH BASIN

JAQUAR - SLS-WHT-6601, 600X400X185MM COUNTER TOP BASIN

STONE THRESHOLD

W

DESCRIPTION

SYMBOL

M

D

ITEM

DESCRIPTION

MIRROR

MIRROR WITH FROSTED BEVELED EDGE AND AIR GAP WITH CLIPS

DUSTBIN

PIGEON STAINLESS STEEL DUSTBIN MATTE FINISH 170MM DIA 300MM HEIGHT

C

A

A' D4

D3

D5

B

B'

240MM THICK BRICK BAT COBA

N

N

RCC PLINTH BEAM

WC

WATER CLOSET

JAQUAR ONS-WHT-10753S, S TRAP RIMLESS COUPLED WATER CLOSET WITH ATTACHED CISTERN

U

URINAL

JAQUAR URS-WHT-13257 TOP INLET URINAL WITH FIXING ACCESSORIES

D6

N

WATER PROOFING ABOVE PCC 100MM THICK PCC FILLING

N

NAHANI TRAP

ROUBLE PACKING

F

2210

CAST IRON FLOOR TRAP WITH STEEL GRATING

FLUSH TANK

DUAL TANK, 10L CAPACITY, CERAMIC CHINAWARE

BIB TAP

JAQUAR 2 WAY BIB TAP WITH WALL FLANGE, OPP-CHR-15041PM

HF

E

HEALTH FAUCET

EXHAUST FAN

D10

D9

JAQUAR ALD-CHR-577 HEALTH FAUCET WITH 8MM DIA 1.2M LONG FLEXIBLE TUBE AND NRV

LUMINOUS EXHAUST FAN VENTO DELUXE 200MM DIA

C

KEY PLAN

EARTH FILLING

BT

PROJECT NAME:

METRO HEAD OFFICE SHEET TITLE:

SHEET NUMBER:

ROOF PLAN

C

ARCHITECTURAL DETAIL

15

SCALE :

DETAIL OF TOILET TILE DROP

NORTH NAME :

CHAITANYAA AGRAWAL

SEMESTER 6

T . Y . B.ARCH

ACADEMY OF ARCHITECTURE, MUMBAI

16

TOILET DETAILS

SIGN AND STAMP

ROLL NO.

02


GENERAL NOTES

1100

10MM POLISHED KOTA STONE RISER STAINLESS STEEL HANDRAIL 25MM THICK ROUGH KOTA STONE TREAD 20MM THICK CEMENT MORTAR 150MM THICK RCC FOLDED STAIRCASE SLAB

160

D8

810

900

D15

1710

1) All dimensions are in 'millimeters' unless specified 2) The drawing is not to be scaled. The dimensions are strictly to be followed. 3) All levels are unfinished levels unless specified. 4) The contractor shall verify all on site dimensions including elevations prior to the commencement of work on site. 5) The contractor shall inform the architect and/or project engineer on site regarding any conditions/ modifications required to be done prior to the commencement of work. 6) The contractor shall coordinate and verify the work indicated on the drawings between the architectural and various trade drawings, including but not limited to structural, electrical, plumbing, fire protection and exterior enclosure systems. 7) All work shall conform to relevant BIS codes and shall be best practice of each trade. 8) Any discrepancy is to be brought to the notice of the architect/ consultant before commencement of the site. 9) All work is to be completed to the satisfaction of site engineer/ project manager and architects

TOR 8MM DIA LINKS AT 150MM C/C

600

1550

STEEL FOR STAIRCASE TOR 8MM DIA MAIN

300

TOR 8MM DIA STIRRUPS AT 300MM C/C

1600

230X600MM RCC BEAM

850

TOR 16MM DIA MAIN STEEL FOR RCC BEAM

SECOND FLOOR LEVEL

ARCHITECTURAL DETAIL DETAILED SECTION THROUGH STAIRCASE LANDING

1100

2900

+7.60M LVL MID LANDING

ANTI SKID GROOVES

230MM THICK BRICK WALL 25MM THICK PLASTER

900

D15

310

D8

15

25MM THICK ROUGH KOTA STONE TREAD TILE

8 8 8

1550

STAINLESS STEEL HANDRAIL

600

ALUMINIUM AWNING WINDOW (2000MM)

20MM THICK CEMENT MORTAR

10MM THICK POLISHED KOTA STONE FOR RISER

FIRST FLOOR LEVEL

TOR 8MM MAIN REINFORCEMENT

140

ACP CLADDING

160

850

FLOOR LANDING

FOR STAIRCASE TOR 8MM LINKS AT 150MM C/C

+4.10M LVL

900

1750

D15 RCC FOLDED SLAB 150MM THICK STAIRCASE

D8

PLINTH LEVEL +0.60M LVL 150 MM THK PCC 230 MM THK RUBBLE SOLING

ARCHITECTURAL DETAIL

MURUM

NOSING DETAIL OF STAIRCASE TREAD SCALE 1:2

REVISION TABLE DATE

REVISION

DESCRIPTION

PART SECTION DETAIL OF STAIRCASE TREAD

80MM DIAMETER HANDRAIL STAINLESS STEEL HOLLOW CIRCULAR SECTION

6600 4750 230MM THICK SHEAR WALL

40 MM DIAMETER BALUSTERS STAINLESS STEEL HOLLOW SECTION

13

14

15

16

17

18

19

20

21

22

230MM THICK BRICK WALL A'

2130

12

FFL = +0.640 M UFL = +0.60 M

3250

2000

W1

FFL = +1.79 M UFL = +1.75 M

1800 25MM THICK PLASTER MID LANDING 22 21 20 19 18 17 16 15

STAINLESS STEEL HANDRAIL

1 2

14

C10

3

13 4

12

5 6 7 8 9 10 11

A

A

A' 11

10

9

8

7

6

5

4

3

2

D15

1

(1710X300) KOTA STONE TILE FOR TREAD FLOOR LANDING ACP CLADDING

C8

6400

KEY PLAN

20MM THICK STAINLESS STEEL BASE PLATE (ANCHOR FASTENED TO STAIRCASE TREAD)

PROJECT NAME:

METRO HEAD OFFICE SHEET TITLE:

1250

810

5050

ALUMINIUM AWNING WINDOW (2000MM)

SHEET NUMBER:

ROOF PLAN

16

SCALE : NORTH NAME :

PART PLAN DETAIL OF STAIRCASE

16

STAIRCASE DETAIL

CHAITANYAA AGRAWAL

SEMESTER 6

ARCHITECTURAL DETAIL DETAIL OF STAIRCASE RAILING AND BALUSTER 1:2

T . Y . B.ARCH

ACADEMY OF ARCHITECTURE, MUMBAI

SIGN AND STAMP

ROLL NO.

02


GENERAL NOTES 1) All dimensions are in 'millimeters' unless specified 2) The drawing is not to be scaled. The dimensions are strictly to be followed. 3) All levels are unfinished levels unless specified. 4) The contractor shall verify all on site dimensions including elevations prior to the commencement of work on site. 5) The contractor shall inform the architect and/or project engineer on site regarding any conditions/ modifications required to be done prior to the commencement of work. 6) The contractor shall coordinate and verify the work indicated on the drawings between the architectural and various trade drawings, including but not limited to structural, electrical, plumbing, fire protection and exterior enclosure systems. 7) All work shall conform to relevant BIS codes and shall be best practice of each trade. 8) Any discrepancy is to be brought to the notice of the architect/ consultant before commencement of the site. 9) All work is to be completed to the satisfaction of site engineer/ project manager and architects

20 MM THK CHINA MOSAIC GASKET

25 MM THK CEMENT MORTAR

VENT HOLE 100MM THK BBC

METAL FLASHING AT PARAPET 100 X 300 MULLION

100

25MM THICK EXTERNAL SANDFACE PLASTER HILTI BOLTS MULLION GRADE 316 SS BRACKET ASSEMBLY AND TENSION ROD

200 MM THK BRICK WALL PARAPET

RCC BEAM (400 MM x 600 MM THK) MS CLIP CONNECTING MULLION TO RCC BEAM 780X1750X100MM ACP PANELS 160 MM THK RCC SUNK SLAB

GRADE 316 SS TENSION ROD

1500

PRESSURE PLATE ALUMINIUM CAPPING

150X100 MS TRANSOM

12

230 MM THK BRICK WALL

45°

EDGE DETAIL A-401

DETAIL SHOWING FACADE SYSTEM

°

95 250 20 MM THK CLEAR HST/LAMINATED GLASS

230 2000

Ø60

300 X 100 TRANSOM GRADE 316 SS BRACKET AND FITTING 195 MM THK FLAT SLAB

780X1750X100MM ACP PANELS

25 THK MM FLOOR FINISH

SECTION

20MM THICK CEMENT MORTAR 150MM RCC SLAB MS CLIP CONNECTING TRANSOM TO MULLION

DETAIL SHOWING GLASS CANOPY SCALE 1:10

MS TRAY FOR FACADE PANEL TO SLIDE 2MM THICK METAL FLASHING AT THE GROUND LEVEL 300X600MM RCC PLINTH BEAM 150 MM THK PCC 230 MM RUBBER SOLING

6000

REVISION TABLE

BACKFILLING

DATE

REVISION

DESCRIPTION

200

END WALL SECTION DETAIL SHOWING FACADE SYSTEM SCALE 1:25

20 MM THK CLEAR HST/LAMINATED GLASS

2000

GRADE 316 SS BRACKET ASSEMBLY AND TENSION ROD

GRADE 316 SS BRACKET AND FITTING

PROJECT NAME:

METRO HEAD OFFICE 300 X 100 TRANSOM

SHEET TITLE:

SHEET NUMBER:

17 100 X 300 MULLION

2000

2000

SCALE :

2000

NORTH

FLAT SLAB

NAME :

CHAITANYAA AGRAWAL

SEMESTER 6

T . Y . B.ARCH

ACADEMY OF ARCHITECTURE, MUMBAI

ARCHITECTURAL DETAILS 17

PLAN DETAIL SHOWING GLASS CANOPY SCALE 1:10

SIGN AND STAMP

ROLL NO.

02