TDG The D’souza Group Project notes: 1. Facade drawings shall be read in conjunction with the specification of glazing and structural engineering services documents. 2. All design discrepancies shall be referred to the design engineer for resolution before proceeding with work. 3. All finishings must be completed before project is signed off.
SARC 321 - Assignment 3 : Facade Design Austin D’souza - 300327560
4. All materials and workmanship shall be in accordance with the NZBC, except where varied by the specification and/or drawings are specificed otherwise. 5. All glazing and other facade and mechanical work must be done by authorised personel only. 6. This 20 storey building is located on 201 Wakefield Street, Wellington, NZ in which the design has the purpose of serving the function of an office. The gross floor area for a single floor is 1000m2. The approximate amount of people expected to occupy each floor is 83 ( 12m2 per person per floor)
North West Corner elevation of typical floor in building
EXPOSED FACADE
AB C
D
E
Rectangular hollow steel beam welded to verticle steel columns, refer to engineer’s specifications
Circular hollow steel braces welded to verticle steel columns, refer to engineer’s specifications
Thermosash Delta40 double glazed curtain wall system with heavy duty mullions
600 Circular hollow sections column CHS 165.1x5.4
1
TDG
F
76
G
All dimentions and levels to be checked on site before work commences. Any discrepancies shall be immediately notified to the architect/project manager in writing. Do not scale from this drawing, use figured dimentions only. If in doubt please consult the architect stated below. This drawing remains the property of TDG and may not be used or reproduced in whole or in part without written permission.
5
4
3
2
10
R 74000
R 74000
19 70300
19 70300
18 66600
18 66600
17 62900
17 62900
16 59200
16 59200
15 55500
15 55500
14 51800
14 51800
13 48100
13 48100
12 44400
12 44400
11 40700
11 40700
10 37000
10 37000
9 33300
9 33300
8 29600
8 29600
7 25900
7 25900
6 22200
6 22200
5 18500
5 18500
4 14800
4 14800
3 11100
3 11100
2
7400
2
7400
1
3700
1
3700
G
0
G
0
West Elevation 1 : 500
SARC 321 - Facade Design
2
North Elevation 1 : 500
Full Elevations - North + West
Austin Dsouza - 300327560
Scale 1:500 - A101
North West Corner plan of typical floor in building
EXPOSED FACADE 300
All dimentions and levels to be checked on site before work commences. Any discrepancies shall be immediately notified to the architect/project manager in writing. Do not scale from this drawing, use figured dimentions only. If in doubt please consult the architect stated below. This drawing remains the property of TDG and may not be used or reproduced in whole or in part without written permission.
600
A Rectangular hollow steel beam welded to verticle steel columns, refer to engineer’s specifications
Thermosash extruded mullion window profile, refer to engineers specifications
B 10mm standard GIB on 90x45mm timber framing for parameter wiring
600 Circular hollow sections column CHS 165.1x5.4
Thermosash Delta40 double glazed curtain wall system with heavy duty mullions
10mm Birch timber vaneer flooring
150mm in-situ reinforced concrete floor covered with 10mm birch vaneer flooring
TDG
SARC 321 - Facade Design
North West Corner Floor Plan - Level 4
Austin Dsouza - 300327560
Scale 1:20 - A102
North West Corner elevation of typical floor in building
7
HIDDEN FACADE
6
5
600
All dimentions and levels to be checked on site before work commences. Any discrepancies shall be immediately notified to the architect/project manager in writing. Do not scale from this drawing, use figured dimentions only. If in doubt please consult the architect stated below. This drawing remains the property of TDG and may not be used or reproduced in whole or in part without written permission.
5th floor
Rectangular hollow steel beam welded to verticle steel columns, refer to engineer’s specifications 3700
Thermosash extruded mullion window profile, refer to engineers specifications 600 Circular hollow sections column CHS 165.1x5.4
4th floor
Exposed colums and beams to be extruded 1.2m out at parameter of floor all floors
Circular hollow steel braces welded to verticle steel columns, refer to engineer’s specifications
Thermosash Delta40 double glazed curtain wall system with heavy duty mullions
3rd floor
250mm concrete upstand into floor slab for glazing units to sit on
150mm in-situ reinforced concrete floor covered with10mm birch vaneer flooring
TDG
SARC 321 - Facade Design
North West Corner Elevation - Level 4
Austin Dsouza - 300327560
Scale 1:50 - A103
North West Corner section of typical floor in building
EXPOSED FACADE Hardies commercial spandrel panel fixed to timber framing
Pink Batts classic R2.2 wall insulation
90x45mm timber framing
GIB rondo metal batten suspended ceiling system
600X600mm celing tiles
300
All dimentions and levels to be checked on site before work commences. Any discrepancies shall be immediately notified to the architect/project manager in writing. Do not scale from this drawing, use figured dimentions only. If in doubt please consult the architect stated below. This drawing remains the property of TDG and may not be used or reproduced in whole or in part without written permission.
Rectangular hollow steel beam welded to verticle steel columns, refer to engineer’s specifications
Thermosash extruded mullion window profile, refer to engineers specifications
Exposed colums and beams to be extruded 1.2m out at parameter of floor all floors
600 Circular hollow sections column CHS 165.1x5.4 5 degree slope on edge for water run-off Thermosash Delta40 double glazed curtain wall system with heavy duty mullions Drip edge as per cladding supplier 10mm standard GIB on 90x45mm timber framing for parameter wiring
10mm Birch timber vaneer flooring
250mm concrete upstand into floor slab for glazing units to sit on
150mm in-situ reinforced concrete floor covered with10mm birch vaneer flooring
TDG
SARC 321 - Facade Design
North West Corner Section - Level 4
Austin Dsouza - 300327560
Scale 1:20 - A104
TDG
SARC 321 - Facade Design
Exposed Facade Render
Austin Dsouza - 300327560
Scale 1:20 - A105
North West Corner elevation of typical floor in building
HIDDEN FACADE
AB C
D
E
F
Triangulated design alternated on every second floor to add visual movement
Larger openings are designed on the NW corner to emphasize the point in the design
500x500mm reinforced concrete columns Normal curtain wall glazing on bottom two stories to emphasize the public floors
TDG
1
West Elevation 1 : 500
SARC 321 - Facade Design
76
G
All dimentions and levels to be checked on site before work commences. Any discrepancies shall be immediately notified to the architect/project manager in writing. Do not scale from this drawing, use figured dimentions only. If in doubt please consult the architect stated below. This drawing remains the property of TDG and may not be used or reproduced in whole or in part without written permission.
5
3
4
2
10
R 74000
R 74000
19 70300
19 70300
18 66600
18 66600
17 62900
17 62900
16 59200
16 59200
15 55500
15 55500
14 51800
14 51800
13 48100
13 48100
12 44400
12 44400
11 40700
11 40700
10 37000
10 37000
9 33300
9 33300
8 29600
8 29600
7 25900
7 25900
6 22200
6 22200
5 18500
5 18500
4 14800
4 14800
3 11100
3 11100
2
7400
2
7400
1
3700
1
3700
G
0
G
0
2
Thermosash angled double glazed low-e windows, refer to specifications Thermosash special engineered mullion window system, refer to engineers specifications
150mm ireinforced concrete floor slab on metal traydec 80, with timber panel underlay covered with commercial carpet
Entrance on main the main road, Wakefeild St
North Elevation 1 : 500
Full Elevations - North + West
Austin Dsouza - 300327560
Scale 1:500 - A106
North West Corner plan of typical floor in building
HIDDEN FACADE
All dimentions and levels to be checked on site before work commences. Any discrepancies shall be immediately notified to the architect/project manager in writing. Do not scale from this drawing, use figured dimentions only. If in doubt please consult the architect stated below. This drawing remains the property of TDG and may not be used or reproduced in whole or in part without written permission.
300
600
Thermosash angled double glazed low-e windows, refer to specifications
500x500mm reinforced concrete column, sitting just inside of curtain wall
B
10mm Birch timber covering for wiring ditch around parameter
Special aluminium triangulated forms fabricated by Thermosash to create hexagonal extrusions and window housing
150mm ireinforced concrete floor slab on metal traydec 80, with timber panel underlay covered with commercial carpet
Top and bottom transom are aligned with the floor slabs that it sits on
TDG
Thermosash special engineered mullion window system, refer to engineers specifications
SARC 321 - Facade Design
North West Corner Floor Plan - Level 4
Austin Dsouza - 300327560
Scale 1:20 - A107
North West Corner elevation of typical floor in building
7
HIDDEN FACADE
All dimentions and levels to be checked on site before work commences. Any discrepancies shall be immediately notified to the architect/project manager in writing. Do not scale from this drawing, use figured dimentions only. If in doubt please consult the architect stated below. This drawing remains the property of TDG and may not be used or reproduced in whole or in part without written permission.
5
6
5th floor
3700
Thermosash extruded mullion window profile, refer to engineers specifications
Hidden colums and beams in the inside of the facade giving effect of floating floors
4th floor
Frosted glass spandrel panel fixed to timber framing
Thermosash angled double glazed low-e windows, refer to specifications
Special aluminium triangulated forms fabricated by Thermosash to create hexagonal extrusions and window housing
Thermosash special engineered mullion window system, refer to engineers specifications 3rd floor
150mm ireinforced concrete floor slab on metal traydec 80, with timber panel underlay covered with commercial carpet
Top and bottom transom are aligned with the floor slabs that it sits on
TDG
SARC 321 - Facade Design
North West Corner Elevation - Level 4
Austin Dsouza - 300327560
Scale 1:50 - A108
North West Corner section of typical floor in building
Steel I beam with 13mm GIB Fyreline as per NZBC C1
Hardies frosted spandrel panel fixed to timber framing
300
90x45mm timber framing
GIB rondo metal batten suspended ceiling system
600X600mm celing tiles
All dimentions and levels to be checked on site before work commences. Any discrepancies shall be immediately notified to the architect/project manager in writing. Do not scale from this drawing, use figured dimentions only. If in doubt please consult the architect stated below. This drawing remains the property of TDG and may not be used or reproduced in whole or in part without written permission.
600
Pink Batts classic R2.2 wall insulation
HIDDEN FACADE
Continuous sealant Top and bottom transom are flush with floor slab so that there is a smooth edge that allows people to come right up to the front
Thermosash angled double glazed low-e windows, refer to specifications
500x500mm reinforced concrete column, sitting just inside of curtain wall
Special aluminium triangulated forms fabricated by Thermosash to create hexagonal extrusions and window housing 10mm Birch timber underlining flooring system
Drip edge as per cladding supplier
150mm ireinforced concrete floor slab on metal traydec 80, with timber panel underlay covered with commercial carpet
TDG
SARC 321 - Facade Design
North West Corner Section - Level 4
Austin Dsouza - 300327560
Scale 1:20 - A109
TDG
SARC 321 - Facade Design
Hidden Facade Render
Austin Dsouza - 300327560
Scale 1:20 - A110
TDG
SARC 321 - Facade Design
Expressive Facade Detail
Austin Dsouza - 300327560
Scale 1:20 - A111