3 minute read

OM1 Multimode Fibre Optic Cables

OM1 Multimode LOOSE TUBE

100m, 200m, 500m, CTL

OM1 loose tube, gel filled cables are multi-mode fibre optic cables using 62.5/125µm fibre. Ideal for extending existing OM1 installations and where low data rates are needed over short distances. OM1 Fibre has been popular for many years but new installations are increasingly needing to carry more data where OM3 and OM4 cables are better suited.

OM1 Multimode 62.5/125µm Loose Tube Fibre Optic Unarmoured - U-DQ(ZN)BH

OM1 Multimode 62.5/125µm Loose Tube Fibre Optic Armoured - U-DQ(ZN)(SR)H

CONSTRUCTION

Single gel filled central tube surrounded by waterblocked E-Glass fibre elements, LSHF UV resistant sheath to IEC 50290-2-27.

OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: OM1

Optical Fibre Standards:

EN 60793-2-10 type A1b TIA/EIA-492 AAAA ANSI/TIA/EIA - 568.B.3 - 2000 EN 50173-1:2007 category OM1 ISO / IEC 11801 category OM1 IEEE 802.3 - 2002 with amendment 802.3ae - 2002

FINISHED CABLE TECHNICAL INFORMATION

Standards: ISO 11801 2nd Edition EN 50173-1-2002 IEC 60794-1 Temperature Rating: Flexing -30°C to +40°C Static -30°C to +60°C Minimum Bend Radius: Unloaded 60mm Loaded 100mm Flame Retardant: IEC/BS EN 60332-1-2 Smoke Emission: IEC/BS EN 61034-2 Halogen Emission: IEC/BS EN 60754-1&2

Part No. No. of Fibres Sheath Material Sheath Colour Weight kg/km

O/D mm

FOM104LUH00 4 LSHF Black 40 6.0 FOM108LUH00 8 LSHF Black 40 6.0 FOM112LUH00 12 LSHF Black 40 6.0 FOM116LUH00 16 LSHF Black 40 6.0 FOM124LUH00 24 LSHF Black 45 6.5

CONSTRUCTION

Single gel filled central tube surrounded by water-blocked E-Glass fibre elements, corrugated steel tape armour, LSHF UV resistant sheath to IEC 50290-2-27.

OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: OM1

Optical Fibre Standards:

EN 60793-2-10 type A1b TIA/EIA-492 AAAA ANSI/TIA/EIA - 568.B.3 - 2000 EN 50173-1:2007 category OM1 ISO / IEC 11801 category OM1 IEEE 802.3 - 2002 with amendment 802.3ae - 2002

FINISHED CABLE TECHNICAL INFORMATION

Standards: ISO 11801 2nd Edition EN 50173-1-2002 IEC 60794-1 Temperature Rating: Flexing -40°C to +70°C Static -40°C to +70°C Minimum Bend Radius: 55mm Flame Retardant: IEC/BS EN 60332-1-2 Smoke Emission: IEC/BS EN 61034-2 Halogen Emission: IEC/BS EN 60754-1&2

Part No. No. of Fibres Armour Sheath Material Sheath Colour Weight kg/km

O/D mm

FOM104LUHC00 4 CST LSHF Black 75 8.5 FOM108LUHC00 8 CST LSHF Black 75 8.5 FOM112LUHC00 12 CST LSHF Black 75 8.5 FOM116LUHC00 16 CST LSHF Black 75 8.5 FOM124LUHC00 24 CST LSHF Black 85 8.5

Low Smoke Halogen Free Armoured

CPR-Compliant Options Available

OM1 TIGHT BUFFERED SINGLEmode 100m, 200m, 500m, CTL

OM1 62.5/125µm tight buffered fibre optic cables lay up, the colour coded fibres surrounded by E-Glass to give it good tensile strength and protection against crush. Ideally suited to indoor applications the cable also has a Low Smoke Halogen Free (LSHF), flame retardant jacket that is UV resistant so can be used outdoors as well.

OM1 Multimode 62.5/125µm Tight Buffered Fibre Optic Unarmoured - U-V(ZN)H CONSTRUCTION

Tight buffered fibres packed along with E-glass roving strength members, LSHF UV resistant sheath to IEC 50290-2-27.

OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: OM1

Optical Fibre Standards:

EN 60793-2-10 type A1b TIA/EIA-492 AAAA ANSI/TIA/EIA - 568.B.3 - 2000 EN 50173-1:2007 category OM1 ISO / IEC 11801 category OM1 IEEE 802.3 - 2002 with amendment 802.3ae - 2002

FINISHED CABLE TECHNICAL INFORMATION

Standards: ISO 11801 2nd Edition EN 50173-1-2002 IEC 60794-1 Temperature Rating: Flexing -20°C to +70°C Static -20°C to +70°C Minimum Bend Radius: Up to 8 fibre 50mm 12 & 16 fibre 75mm Flame Retardant: IEC/BS EN 60332-1-2 Smoke Emission: IEC/BS EN 61034-2 Halogen Emission: IEC/BS EN 60754-1&2

Part No. No. of Fibres Sheath Material Sheath Colour Weight kg/km

O/D mm

FOM104TUH00 4 LSHF Black 34 6.5 FOM108TUH00 8 LSHF Black 39 7.0 FOM112TUH00 12 LSHF Black 43 7.5 FOM116TUH00 16 LSHF Black 52 8.0 FOM124TUH00 24 LSHF Black 63 8.5

Low Smoke Halogen Free

CPR-Compliant Options Available

This article is from: