Footing: (L mm x W mm x D mm) 1. F3: 2500 x 1200 x 600 MIN: SLB1 Bottom 2. F6: 1500 x 1500 x 600 MIN: N12-200 crs bottom both directions 3. F7: 1200 x 1200 x 600 MIN: SLB1 Bottom 4. F8: 600 x 600 x 600 MIN: SLB1 Bottom with 75mm concrete encasement, 4M20 – 4.6/S H.D. bolts, 400mm embedment, 100mm COG caged, 20mm thick based plate, 6mm CFW all round, 20mm non-shrink grout Concrete block 5. Bored Piers (BP1) - To be founded in weathered siltstone with a founding depth of 2000mm below finish surface level, with N20 x 2000 Long “L” Bar and 300 cog tied to top slab reinforcement   Ground Floor Slab: 1. EB1: F’c = 15MPa, 300mmx600mm min deep, with 3L12 trench mesh Top and Bottom along with N12- 200 centres “Z Bars” vertical lapped at 400mm pad footing will be formed first prior to installation of geothermal pipes 2. Waterproof membrane: ‘Fortecon Super’ flexible polymeric film 0.3mm thick 3. Compressive strength of the concrete slab 32MPA 4. 150mm Polystyrene insulation

R

A

Foundation/Geotechnical Report: 1. Site Classification M= Moderately reactive clay or silt sites, which may experience moderate ground movement from moisture changes 20 - 40mm 2. Bore Hole 1 - Fill: 0.0 – 0.80; crushed rocked capped by 30mm asphalt | grey | moist, sand, cement stabilised | medium dense | using approved excavated material, clean inorganic material, hardcore: clean hard filling such as broken brick or stone rubble, porous filling: hard core graded from 40mm to 15mm, sand: salt free, loam free, packing quality and fine crushed rock: 15 to 5mm clean crushed rock - Clay (CL): 0.80 – 1.90; orange, brown | moist, silty | stiff | tending to extremely weathered siltstone from 1.9 metres - Clay/Siltstone: 1.90 – 3.00; Orange/brown | moist, silty, extremely weathered lenses stiff - Siltstone: 3.00 – 4.00; extremely weathered, yellow orange, silty and gravels | very low rock strength 3. Mass concrete with minimum depth of 1m till it reaches the weathered siltstone on all pad footings 4. 50mm minimum thick blinding concrete (compressive strength of 15MPa) as surface levelling below concrete slabs, edge beams 5. All water should be collected and channelled away from the proposed structure. Water should not be permitted to pond in the footing 6. Termite control: All gund areas are treated against termite in accordance with the requirement of AS 3360 using approved mechanical termite shield (Granite-Gard, Termi-Mesh or equal approved). Organo chlorine termicides are not to be used.

U

D

R T

Q

R L. 4 .0 41

E

Ground floor lining: 1. Female Toilet floor lining: V1A Sheet Vinyl Armstrong ‘Contour’, 2.0mm thick. Coved 100mm up walls. Colour: Lime_921-037/ Slip rating: R9 2. Circulation: V1B Sheet Vinyl Armstrong ‘Contour’, 2.0mm thick. Coved 100mm up walls. 2 Colour: Silver_921-051/ Slip rating: R9 3. Theatrette 1 floor lining: C-1B Carpet, broadloom, trails tile, installed using direct stick method.

W

Column: 1. CC3: 400 x 300 concrete column 2. C2: 310 UB 40: Screening column 3. 3x13mm Layers of Fire rated plasterboard to provide 12/-/- fire protection to structural steel column 4. 400 x 300mm concrete column (CC3): reinforced with 8R24 deformed bars with R12 Ligs at 300 centres with 300mm cogs lapped at 800 with the starter bars at ends cast into F6 and onto IB8 5. Lig Concrete cover: 40mm 6. Slab are placed using vibrating screed or equivalent poker vibrator 7. Beam reinforcement shall continue through pad footing

N

.4 5 37 L. R

3 . L R

I

N

P

Theatrette 1 ceiling (Ground Floor): 1. Acoustic Insulation: Blanket 75mm thick, 14kg/m3 2. Rondo ‘Key Lock’ with Rondo exangle corner bead PX1 and Ground Floor Ceiling 3. Timber lining: Atkar ‘Au.di.Slot’ AS26-40/80 slotted panel with integrated acoustic backing: 9mm thick plywood substrate panels pre-finished with Au.diStyle ‘Tas Oak’ finish by Atkar with a 20mm clear border to panels and edges. Concealed fixing with 5mm expressed joints

.0

36

L

M

Circulation ceiling (Ground Floor): 1. Rondo ‘Key Lock’ with Rondo exangle corner bead PX1 2. Gyprock Supaceil perforated Plasterboard 10mm

H D3 F

O

5

Window: 1. Backing rod and silicone seal to finish against window frame; finish with plasterboard with P-50 trim 2. 100mm wide powder; coated aluminium centre; glazed window frame 3. 50mm x 3mm matching aluminium angle to close off gap between block work and window frame 4. Skirting 100mm x 3mm Aluminium, Natural Anodised. 5. Laminated glass, clear. Min. 6.38mm A grade safety glass. Max. Whole of window U value in aluminium frame: 6.4 W/m².K, Max. SHGC: 0.73.

K

L.

K

15 . 7

R

J

6 08

H

Female toilet ceiling (Ground Floor): 1. Female toilet: Rondo ‘Key Lock’ with Rondo exangle corner bead PX1 and Ground Floor Ceiling 2. WPB- Gyprock Aquacheck Plasterboard, 10mm

V

. 39

G

Ground Floor Female Toilet Wall: 1. Precast concrete panel: 150m thick 2. Concrete block 390x90x90, honed face, hollow half high block honed finished series 100 laid in stretcher bond 3. Stud wall with USG Powerscape “Fibrerock aquatough” 13mm internal wall lining board with recessed edges 4. Composite aluminium external cladding with 800mm block work dado

I

L.

R

F

Ground floor curved Wall (from external to internal): 1. 120min Fire rating – CSR 908 or CSR 123 2. Alucbond: Panels 4mm thick, joints nominally 10mm, utilising ‘Direct Stick’ cladding technique and ‘Type-3’ edge treatment to exposed edges; support alucbond where installed horizontally on 19mm marine grade plywood; colour: solid light grey 104 surf 3. 2x16mm Fire rated and moisture resistant plasterboard 90mm stud frame with 90x 45 MGP10 timber plates and 90 x 35 MGP 10 timber studs 4. with CSR Bradford ‘Breatherfoil Antiglare’ vapour permeable sarking 5. Insulation thermal: CSR Bradford ‘Gold’ wall batts, R2.5 (90mm thick) to achieve thermal rating of R2.8 6. Gyprock, flexible plasterboard, 2x6.5mm 7. 90mm stud frame with CSR Bradford ‘Breatherfoil Antiglare’ vapour permeable sarking 8. Insulation batt 14mm thick

E

M

First Floor Slab: 1. Live end anchorage for post tensioned reinforcement with 4 strands of 12.7mm diameter bars, with bottom reinforcement of T7 (N12-300) and T6 (N12-250) and top reinforcement of N12-400 bar 2. 1mm Condek 3. 160mm Concrete Slab 4. Concrete Strength: 40MPa 5. N-12 200 centres reinforcement steel on the perimeter of the concrete

D2

D1

G

First floor lining: 1. Group discussion room floor lining: C2B: RC&D_(Rugs Carpets by Design) HL 630/MOD 750 RFM52206564_Trails_Carpet Tile 2. Theatrette Floor lining: C-1 Carpet, broadloom, trails, carpet tiles installed using direct stick method.

L.

R

N

Steel Access Stairs (riser: 180mm; going 250mm) SB1: 230 x 75 PFC: Stairs stringer hot dip galvanised

K

L

Stairs: 1. 2.

L.

R

B

25

SF7 First Floor: 1. 90mm stud frame 2. 2x6.5mm Gyprock flexible plasterboard

3

SF12 First Floor: 1. CSR Bradford ‘Breatherfoil Antiglare’ vapour permeable sarking 2. 90mm stud wall with Alucbond: Panels 4mm thick, joints nominally 10mm, utilising ‘Direct Stick’ cladding technique and ‘Type-3’ edge treatment to exposed edges; support alucbond where installed horizontally on 19mm marine grade plywood; colour: solid light grey 104 surf

Concrete

Clay (CL)

Sand

Clay/Siltstone

Vinyl

Siltstone

Carpet

Insulation

Safety Mesh

B

Theatrette 2 Ceiling: 1. Gyprock, plasterboard CD 2x6.5mm 2. Rondo ‘Key Lock’ with Rondo exangle corner bead PX1 3. TL-2: Timber lining: Atkar ‘Au.di.Slot’ AS26-40/80 slotted panel with integrated acoustic backing: 9mm thick plywood substrate panels pre-finished with Au.diStyle ‘Tas Oak’ finish by Atkar with a 20mm clear border to panels and edges. Concealed fixing with 5mm expressed joints 4. TL-3: Timber Panels to match Atkar Au.di.Slot ‘Tas Oak’ Finish; 9mm thick plywood substrate panels with Au.diStyle ‘Tas Oak’ finish by Atkar; the edge profile shall be chamfer edge profile with Au.diStyle. Concealed fixings with 5mm expressed joints. Group Discussion Ceiling: 1. Gyprock, plasterboard CD 2x6.5mm 2. Rondo ‘Key Lock’ with Rondo exangle corner bead PX1 Roof structure for Group discussion room: 1. Safety Mesh for insulation 2. B1: 150 PFC 3. WHI: 150 PFC (Rotated horizontally) 4. WH2: 200 PFC (Rotated horizontally) 5. WH3: 230 PFC (Rotated horizontally) 6. C20024: Stramit C Section Purlin, Strength: MPA-G450 7. RB2: 20mm diameter rod

Roofing lining: 1. Bluescope Lysaght, ‘Spandek’, 0.48 BMT, Colourbond finish (blue colour) 2. CSR Bradford ‘Anticon 130’ Roofing Blanket incorporating medium duty Thermofoil 730 R3.0; CSR ‘Ashgrid’ 110mm metal spacer installed all over blanket 3. Galvanised Wire Safety Mesh: Ausmesh 200 or Waratah ‘Roofsafe’

Fill

15

SF9 First Floor: 1. 2x6.5mm Gyprock flexible plasterboard 2. 90mm stud frame 3. CSR Bradford ‘Breatherfoil Antiglare’ vapour permeable sarking

Roof structure for Theatrette 2 room: 1. Safety Mesh for insulation 2. B1: 150 PFC 3. WH3: 230 PFC (Rotated horizontally); C1 connection to WH3; 2 M20- 8.8/s bolts; 10mm cleat plate; 6mm continuous butt weld to cast in plate 4. WB1: 70 x 5.0 Flat Mild Steel Plate 5. P1: Z20024- 1200 Max centres 6. T2: 125 x75 x 6.0 Unequal Angle 7. RB1: 16mm dimeter rod 8. WH1: 150 PFC (Rotated horizontally)

35

A

5 .1 28

Y

. 30

X

B

L.

W

B

R

V

SF3 First floor Wall: 1. Alucbond: Panels 4mm thick, joints nominally 10mm, utilising ‘Direct Stick’ cladding technique and ‘Type-3’ edge treatment to exposed edges; support alucbond where installed horizontally on 19mm marine grade plywood; colour: solid light grey 104 surf 2. 2xPB Gyprock Fyrechek/ Fyrechek MR Plasterboard 3. 90mm stud frame 4. CSR Bradford ‘Breatherfoil Antiglare’ vapour permeable sarking 5. Insulation thermal: CSR Bradford ‘Gold – High Performance’ wall batts, R2.7 (90mm thick). Overall system include masonry/ air film/ internal lining achieves R value of R2.9 minimum

. 29 L.

U

E2

R

T

C

L. R

S

SF1 First floor Wall: 1. 390x90x90mm high face blockwork in stack bond 2. 50mm gap 3. 90mm stud frame with CSR Bradford ‘Breatherfoil Antiglare’ vapour permeable sarking 4. USG Powerscape “Fibrerock aquatough” 13mm internal wall lining board with recessed edges

L

R

. 31 L.

Q

R

P

First Floor Beams 1. 300W x 600D deep beam 2. N12 at 300/200 centres ligatures, lapped at 900mm with reinforcement steel 3. N16 x 500mm long at 200mm max centres tailed cast in ferrules at top and bottom of beams 4. 3N20 OR N24 deformed bars at 800mm

4

O

5 .3 .1 32 32

E3

Sarking

CONSTRUCTION DESIGN | AXONOMETRIC DRAWING

N E

ELIZABETH BLACKBURN SCHOOL OF SCIENCES | CLARKE HOPKINS CLARKE CATHERINE KHO | 813073 | YI LOBACHEVSKY | T13 SECTION E | SCALE 1:20 @A0

N


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.