ON THE RACK LOADING • THERE ARE SIX CHALLENGES TERMINAL OPERATORS FACE WITH BOTTOM LOADING API COUPLERS. OPW’S DAVID MORROW* OFFERS SOME SOLUTIONS WITHOUT DOUBT, THE piece of equipment that is the true workhorse in any type of liquids storage terminal is the bottomloading API coupler that serves as the conduit between the loading arms and the tank truck. In high-volume terminals, it is not unusual for these couplers to be connected and disconnected more than 50 times a day. That is 50-plus head-on collisions between the coupler and adaptor, which translates into a huge amount of use and abuse. Over the years, the design and operation of API couplers (also known as ‘load heads’) has

evolved to the point that they can reliably withstand the abuse that they are subjected to on a daily basis. However, the most dependable terminal liquid transfer operations are the ones in which the terminal makes every effort to ensure that the couplers and their components are cared for to the extent that the operation will consistently run smoothly. Terminals that experience excessive interruptions in their liquid transfer service are ones that cannot meet the demanding delivery schedules of their customers, with the result being lost revenue for both and

– maybe even more damaging – a loss of reputation. With that in mind, there are six areas of concern that terminal operators must be on the lookout for and remedy if the efficiency of their couplers and their overall loading rack operations are to meet expected operational standards. THE SIX CHALLENGES Seal wear If a coupler is experiencing leaks after it is connected to the delivery vehicle, the most likely culprit is a worn seal. Specifically, the nose seal, which is the primary link between the truck and the coupler, may need to be replaced. Terminal operators must monitor this seal constantly and replace it at any sign of wear, lest a leak point develop. Loading arm adjustment Another potential cause of leaks could be the positioning of the loading arms. Ideally, the loading arms should be balanced at the truck adaptor’s height of 30 to 35 inches off grade. If the arms are positioned either lower or higher than recommended, undue stress on the loading system can result, which can lead to the creation of leak paths. Weak or broken wave springs While the first two conditions will generally result in minor leaks, a weak or broken wave spring in the coupler can lead to a significant product loss. The wave spring is critical in producing effective coupler operation because it creates seal compression when it is connected to the truck adaptor. Closely monitoring the performance of the wave spring is important because if it were to break, resulting in insufficient seal compression, the coupler will need to be taken out of service. And while it is replaced, that downtime will compromise fuel-delivery schedules. Thermal expansion Most couplers are rated for use at 75 to 80 psi (5.2 to 5.5 bar) but they can experience much higher pressures if thermal reliefs are not in place and functioning properly. In fact, extreme thermal expansion can create pressures in excess of 300 to 500 psi (20.7 to 34.5 bar). At pressures

HCB MONTHLY | NOVEMBER 2020


Turn static files into dynamic content formats.

Create a flipbook

Articles inside

Labeline puts Roadshow on the web

15min
pages 60-65

Maersk Honam incident report

6min
pages 58-59

Incident Log An emerging hazard

6min
pages 56-57

Conference Diary

2min
page 55

American Club/ABS e-learning

2min
page 54

News bulletin – chemical distribution

6min
pages 52-53

CBA reports increased sales in UK

2min
page 51

Looking forward to Med Hub Day

2min
page 45

OPW answers coupler challenges

5min
pages 40-41

Vopak invests with friends

3min
pages 42-44

News bulletin – storage terminals

6min
pages 46-47

Brenntag lays out new strategy

2min
page 50

Packwise trials Smart Cap for IBCs

2min
page 39

Nexxiot improves rail visibility

3min
page 38

Dawson provides home for alternative fuel

3min
pages 34-35

UKPIA on downstream role

5min
pages 32-33

Railvis.com shows the way

3min
pages 36-37

Odfjell investigates fuel cells

5min
pages 30-31

OCS programme gets attention

12min
pages 26-29

Antwerp a hub for innovation

5min
pages 24-25

News bulletin – tanks and logistics

5min
pages 22-23

Stolt-Nielsen improves profitability

3min
pages 20-21

VOLUME 41 • NUMBER

14min
pages 12-16

Learning by Training

2min
pages 7-8

Reporting back from EPCA

10min
pages 9-11

New approach from Van den Bosch

2min
page 17

30 Years Ago

2min
page 6

Den Hartogh invests in China

2min
page 18

Fort Vale’s new PFA-lined valves

3min
page 19

Letter from the Editor

4min
pages 3-5
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.