Custom Wayfinding Signage Package -- Lenoir, NC

Page 1

LENOIR WAYFINDING

a citywide wayfinding system



CONTACT

CONTENTS A1 GENERAL WAYFINDING NOTES B1 TYPOGRAPHY STANDARDS

CITY OF LENOIR PO BOX 958 801 WEST AVENUE NW LENOIR, NC 28645 828.757.2200

LANDSCAPE ARCHITECT / PROJECT MANAGER: DESTINATION BY DESIGN 136 FURMAN RD, SUITE 6 BOONE, NC 28607 828.386.1866

C1-C2

SIGN PLACEMENT GUIDELINES

D1 SIGNAGE SYSTEM OVERVIEW

STRUCTURAL ENGINEER: ARETE ENGINEERS, PLLC 7668 VALLEY BLVD. BLOWING ROCK, NC 28607 828.434.0587

E1-E5

DESIGN INTENT

S1-S5

STRUCTURAL DRAWINGS

G1-G50

LOCATIONS PLAN


NOTES: INTENT AND CONTRACTOR SCOPE

These drawings are intended to provide sufficient information to convey general design intent to the sign fabricator/installer and are not for construction. Additional technical advice and detailing may be required for successful completion of this project and is the sign fabricator/installer’s responsibility. Sign fabricator shall be responsible for all site engineering. This shall include verifying the mounting conditions and providing a detail drawing for each mounting condition. Sign fabricator/installer shall provide shop drawings to the Owners and/ or designer for each sign type showing fabrication, mounting system, and installation details. Include fabrication plans, elevations, and component details. Indicate materials, fittings, finishes, fasteners, anchorages, and accessory items. The fabricator/ installer shall notify Destination by Design (828-386-1866) of any discrepancies in the fabrication documents immediately and shall not proceed or allow sub-fabricators to work in those areas until said discrepancies are resolved. When changes are required, for any reason, notify Destination by Design (828-386-1866) before performing any work. Changes which alter the contract documents must have the approval of Destination by Design before commencement of such work. Changes which modify the contract amount must have the approval of Destination by Design and Owner before commencement of such work.

CODES

Sign fabricator/installer shall follow the MUTCD (Manual on Uniform Traffic Control Devices) guidelines for Lateral Offsets. See section 2A.19 Lateral Offset in the Manual on Uniform Traffic Control Devices, 2009 Edition. Standardization of Sign Location & Mounting Heights: Signs requiring different decisions by the road user shall be spaced sufficiently using the MUTCD Standards as a guideline. Where parking or pedestrian movements occur, the clearance to the bottom of the sign shall be at least 7 ft. clearance above grade. Sign fabricator shall ensure that actual sign locations are verified by municipality representative and the North Carolina Department of Transportation (NCDOT), as required, prior to installation. Sign fabricator/ installer shall be responsible for providing and paying for all permits, work, and materials in accordance with all codes, ordinances and regulations applicable at the project location.

WARRANTY

All materials and workmanship shall be guaranteed by the sign fabricator/ installer for five (5) years from the date of substantial completion.

SAMPLES

Fabricator shall conform to these drawings and specifications and submit to Destination by Design samples for all finishes included in their scope of work before commencement of such work. For the purpose of the Request for Proposal process, proprietary names identifying items of work are used solely to describe the standard of the product or the color of the finish, unless the items of work are explicitly noted as not having an equal. Fabricator shall secure approval of any substitutions from Destination by Design. Any items approved for substitution should be submitted to Destination by Design for final approval.

OTHER

Sign fabricator/installer shall be responsible for contacting North Carolina 811 before start of project. Sign fabricator/installer is responsible for the means, methods and techniques of installation, safety precautions in connection with the work, and for the acts or omissions of the subcontractors. Sign fabricator/installer shall provide adequate erosion control as required during the course of the project. All wood in contact with the ground, slabs on grade, or masonry is to be pressure treated. Sign fabricator/installer shall protect all surfaces not involved in the work from any damage. Sign fabricator/installer shall repair all surfaces damaged during the installation of the sign system. The sign fabricator/installer shall keep the site work area(s) clear of unnecessary debris; and shall keep all work area(s) secured when unattended for the duration of the installation period.

DESIGN OWNERSHIP

All ideas, designs, arrangements and plans indicated or presented by these drawings are owned by and are the property of the Owner, and were created, evolved and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of Destination by Design and the Owner. Any and all inquiries in this regard by outside parties should be referred to Destination by Design. In addition, the fabricator must request and receive written approvals to use images of any completed element described in these documents in print or promotional materials of any kind including video, from both Destination by Design and the Owner in order to proceed with publication. Permission to use images of the work for promotional or editorial purposes requires that the Fabricator be responsible for ensuring that credit indicating Destination by Design as the designer be adjacent to those images. If an article in a publication accompanies the images, Destination by Design must be identified as the designer in that article as well.

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GENERAL WAYFINDING NOTES

A-1


Clearview Highway 2 - W ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz 1234567890 “!@#$%^

USE OF ARROWS: WHEN MULTIPLE DIRECTIONS ARE REQUIRED ON A SIGN, THE FOLLOWING DIRECTIONAL HIERARCHY SHALL TAKE PRECEDENT. SEE EXAMPLE BELOW. REFERENCE MESSAGE SCHEDULE FOR INDIVIDUAL MESSAGES. THIS PLAN UTILIZES THE “TYPE B” ARROW FOUND IN MUTCD SECTION 2D.08 FOR ARROW USE ON GUIDE SIGNS. NOTE: THE “STANDARD HIGHWAY SIGNS AND MARKINGS” BOOK CONTAINS THE DETAILS OF THESE ARROW DESIGNS.

The City of Lenoir, incorporated in 1851, was named in recognition of William Lenoir, a hero of the Revolutionary War and early North Carolina entrepreneur. Lenoir acceptable

Lenoir

NOT acceptable

Straight Arrow

Left Arrow

Right Arrow

Le no ir

NOT acceptable

USE OF PICTOGRAPHS:

1234

acceptable

1234

NOT acceptable

123 4

NOT acceptable

Access to Mountain Bike Trails

LETTER SPACING Inconsistencies in Letter Spacing

Corrected Letter Spacing

Le noir

Lenoir

Access to Greenways

IMP O RTANT: Individ ual sp ac i ng of eac h l etter needs to b e e va lu a ted . See Examp l es to the l eft. Ke rn al l Cop y so that eac h c harac ter is optic al l y ce nte re d b etween the center of eac h of the surround i ng ch ara cters.

SIGN TEXT STANDARDS� COPY H EIG H T: To measure copy height, only m e as u re th e he ig h t of th e capita l l etters to deter mine yo u r o ve ra ll co py h e ig ht (s hown b el ow as “X”). Som e of the o th e r lette rs h ave a n ex tended height beyond the a ve rag e h e ig ht of th e letters.

LINE SPACING: To me asure l ine sp ac ing, al ways measure from the bas e line of the top most text l ine to the b asel i ne of the tex t lin e b el ow ( shown as “X”) .

X GREENWAY

GREENWAY X GREENWAY

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

TYPOGRAPHY STANDARDS

Ph: 828.386.1866

B-1

Date June 2022


NOTES: (1) UNLESS APPROVED BY DESTINATION BY DESIGN (828-386-1866), SIGNS SHOULD BE LOCATED ON THE RIGHT-HAND SIDE OF THE ROADWAY (SEE MUTCD SECTION 2A.16 FOR STANDARDIZATION OF LOCATION). (2) SEE MUTCD SECTION 2A.19 FOR REDUCED LATERAL OFFSET DISTANCES THAT MAY BE USED IN AREAS WHERE LATERAL OFFSETS ARE LIMITED, AND IN BUSINESS, COMMERCIAL, OR RESIDENTIAL AREAS WHERE SIDEWALK WIDTH IS LIMITED OR WHERE EXISTING POLES ARE CLOSE TO THE CURB. (3) SEE MUTCD SECTION 2A.18 FOR MOUNTING HEIGHT. THE MINIMUM HEIGHT, MEASURED VERTICALLY FROM THE BOTTOM OF THE SIGN TO THE ELEVATION OF THE NEAR EDGE OF THE PAVEMENT, OF SIGNS INSTALLED AT THE SIDE OF THE ROAD IN RURAL AREAS SHALL BE 5 FEET (SEE DETAILS 1 & 2/SHEET C-1). THE MINIMUM HEIGHT, MEASURED VERTICALLY FROM THE BOTTOM OF THE SIGN TO THE ELEVATION OF THE NEAR EDGE OF THE TRAVELED WAY, OF SIGNS INSTALLED AT THE SIDE OF THE ROAD IN BUSINESS, COMMERCIAL, OR RESIDENTIAL AREAS WHERE PARKING OR PEDESTRIAN MOVEMENTS ARE LIKELY TO OCCUR, OT WHERE THE VIEW OF THE SIGN MIGHT BE OBSTRUCTED, SHALL BE 7 FEET (SEE DETAIL 3/ SHEET C-1).

5 FT MIN.

12 FT MIN.

2 ROADSIDE SIGN IN A RURAL AREA WITH A SHOULDER

SIGN

PRIORITY PLACEMENT DISTANCE BETWEEN TWO SIGNS

*SPEED DEPENDENT

SIGN

7 FT* MIN.

>50’

2 FT MIN.

200’-250’

100’-400’

1 ROADSIDE SIGN IN A RURAL AREA

6 FT MIN.

5 FT MIN.

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

3 ROADSIDE SIGN IN A BUSINESS, COMMERCIAL, OR RESIDENTIAL AREA

4 SIGN PLACEMENT GUIDELINES

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

*NOT TO SCALE

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

SIGN PLACEMENT GUIDELINES

Date June 2022

Ph: 828.386.1866

C-1


LEGEND: MEASURE

F

C

MINIMUM DISTANCE

OPTIMAL DISTANCE

A

DISTANCE FROM EDGE OF SIGN PANEL TO EDGE OF CURB

1’-0”

2’-0” OR MORE

B

DISTANCE FROM SIGN POST TO NEAREST OBSTRUCTION

3’-0”

4’-0” OR MORE

C

DISTANCE FROM EDGE OF SIGN PANEL TO NEAREST OVERHEAD OBSTRUCTION

1’-0”

4’-0” OR MORE

D

SIGN PLACEMENT IN RELATION TO ADJACENT BUILDING

DO NOT OBSTRUCT ENTRANCE

ALIGN TO BUILDING EDGE

E

DISTANCE FROM FACE OF SIGN TO NEAREST TREE BRANCH

15’-0”

20’-0” OR MORE

F

DISTANCE FROM BACK OF SIGN TO NEAREST TREE BRANCH

3’-0”

8’-0” OR MORE

G

DISTANCE FROM FACE OF SIGN TO NEAREST UTILITY POLE

10’-0”

15’-0” OR MORE

H

DISTANCE FROM BACK OF SIGN TO NEAREST UTILITY POLE

10’-0”

15’-0” OR MORE

B E

H

G

A

FIELD NOTES:

D

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

SIGN PLACEMENT GUIDELINES

Date June 2022

Ph: 828.386.1866

C-2


LOCAL CREATOR ARTWORK TYP.; SEE EXHIBT

LOCAL CREATOR ARTWORK TYP.; SEE EXHIBT

LOCAL CREATOR ARTWORK TYP.; SEE EXHIBT

LOCAL CREATOR ACCENTS EXHIBIT:

LOCAL CREATOR ARTWORK TYP.; SEE EXHIBT

THE LOCAL CREATOR ACCENTS SPACE IS AN AREA ON SIGNAGE PRESERVED FOR LOCAL ARTISTS TO DESIGN AND INSTALL SCULPTURAL ELEMENTS THAT CELEBRATE THE CITY OF LENOIR’S INDUSTRIAL AND ARTISTIC ROOTS.

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

SIGNAGE SYSTEM OVERVIEW

Date June 2022

Ph: 828.386.1866

D-1


5'-6" 5'

6"

DESTINATION PANEL LAYOUT NOTES:

(4) ALL GRAPHICS SHOWN ARE FOR ILLUSTRATIVE PURPOSES ONLY. CONTACT DESTINATION BY DESIGN FOR BASE ADOBE ILLUSTRATOR FILES (828-386-1866). DESTINATION BY DESIGN TO PROVIDE TYPICALS FOR EACH SIZE PANEL. THE CONTRACTOR SHALL PROVIDE FINAL FOR PRINT PROOF AT EACH SIGN LOCATION.

3" 5"

4"

1"

1"

(3) ALL PANELS OF 1/4” ALUMINUM.

3" MIN.

3"

3"

(2) PANEL LAYOUTS FOR ALL SIGN LOCATIONS SHALL BE INCLUDED IN SHOP DRAWINGS FOR REVIEW BY DESTINATION BY DESIGN (828-386-1866).

8"

2" 5"

5"

(1) MESSAGES SHOWN ARE FOR ILLUSTRATIVE PURPOSES ONLY. REFER TO SECTION H FOR SIGN MESSAGES.

3" 2" 3"

3" MIN.

3"

10"

1'-9" 6'-6"

4"

4"

1'-6"

10"

8"

2"

3" 2" 3"

6'

1'-4"

1'-9"

6"

MINOR WAYFINDING DESTINATION PANEL

MAJOR WAYFINDING DESTINATION PANEL 4'-6"

6'

MINOR WAYFINDING BACK PANEL COLOR SAMPLE

NAME NAVY

PANTONE ID 3035 C

7"

6'-6"

6"

4'

MAJOR WAYFINDING BACK PANEL

WAYFINDING SYSTEM

DETAILS For Paint color match to Pantone. Surface applied, exterior paint and protective top coat: MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish. For vinyl print with approved 3M MCS Printing Methods.

DARK TEAL

2221 C

For Paint color match to Pantone. Surface applied, exterior paint and protective top coat: MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish. For vinyl print with approved 3M MCS Printing Methods.

MEDIUM TEAL

2232 C

For Paint color match to Pantone. Surface applied, exterior paint and protective top coat: MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish. For vinyl print with approved 3M MCS Printing Methods.

Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

DESTINATION PANELS

Date June 2022

Ph: 828.386.1866

E-1


FABRICATION COMPONENTS:

create with us

1

POST: TWO (2) 12” X 4” X 1/4” ALUMINUM POSTS TO FORM “L” SHAPE

2

DESTINATION PANEL: 1/4 INCH ALUMINUM SHEET WITH 3MTM 3930 HIGH INTENSITY PRISMATIC SHEETING APPLIED ON RAW SURFACE. EDGE AND BACK TO HAVE MATTHEWS PAINT.

3

BACK DESTINATION PANEL: 1/4 INCH ALUMINUM WITH 3M SCOTCHAL GRAPHIC FILM IJ3650 APPLIED ON RAW SURFACE. EDGE OF SHEET TO HAVE MATTHEWS PAINT.

4

PANEL SUPPORT: 4” X 4” X 1/4” STEEL FRAME (4’W X 5.5’H 3 SIDED RECTANGLE) WELDED TO SIDE OF MAIN SUPPORT WITH HOLES FOR PANEL ATTACHMENT. SEE STRUCTURAL.

5

LETTERING: 1/4 INCH ALUMINUM LETTERING (6” TEXT HEIGHT) AFFIXED ON THE SIDE OF THE MAIN SUPPORT - CENTERED WITH POST AND PANEL HEIGHT. FONT: DDC HARDWARE.

6

BASE: CONNECTION TO FOUNDATION WITH NCDOT BREAKAWAY SYSTEM (TRANSPO OR EQUAL) SEE STRUCTURAL DRAWINGS .

7

LOCAL CREATOR ACCENTS SPACE: METAL DETAILS ON TOP AND BOTTOM OF DESTINATION PANEL. ATTACHED TO SIDE OF MAIN SUPPORT AND TOP/BOTTOM OF PANEL SUPPORT. TOP DETAIL NOT TO EXCEED 5’ W X 1’6” H. BOTTOM DETAIL NOT TO EXCEED 4’ W X 1’H.

FINISHES PALETTE: P1

“BURNT RUST” POWDER COAT (PTB 6884/TEXTURE): POLYURETHANE TEXTURE POWDER COAT WITH FLAT FINISH BY PRISMATIC POWDERS.

P2

“STAINLESS”: BRUSHED ALUMINUM WITH CLEAR COAT PROTECTION.

P3

BLUE MATTHEW’S PAINT: COLOR MATCH TO PANTONE 3035 C. SUBSTRATE SHOULD BE PRIMED PRIOR TO TOPCOAT. SATIN FINISH.

VINYL SHEETING: V1

REFLECTIVE 3MTM 3930 HIGH INTENSITY PRISMATIC SHEETING: TO BE PRINTED WITH APPROVED 3M MCS PRINTING METHODS.

V2 3M SCOTCHCAL GRAPHIC FILM IJ3650: TO BE PRINTED WITH APPROVED 3M MCS PRINTING METHODS.

NOTES: ALL ATTACHMENT HARDWARE MADE INCONSPICUOUS, PAINTED TO MATCH ATTACHMENT SURFACE.

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

MAJOR WAYFINDING (LOCAL CREATOR)

E-2


FABRICATION COMPONENTS:

create with us

1

POST: TWO (2) 12” X 4” X 1/4” ALUMINUM POSTS TO FORM “L” SHAPE

2

DESTINATION PANEL: 1/4 INCH ALUMINUM SHEET WITH 3MTM 3930 HIGH INTENSITY PRISMATIC SHEETING APPLIED ON RAW SURFACE. EDGE AND BACK TO HAVE MATTHEWS PAINT.

3

BACK DESTINATION PANEL: 1/4 INCH ALUMINUM WITH 3M SCOTCHAL GRAPHIC FILM IJ3650 APPLIED ON RAW SURFACE. EDGE OF SHEET TO HAVE MATTHEWS PAINT.

4

PANEL SUPPORT: 4” X 4” X 1/4” STEEL FRAME (4’W X 5.5’H 3 SIDED RECTANGLE) WELDED TO SIDE OF MAIN SUPPORT WITH HOLES FOR PANEL ATTACHMENT. SEE STRUCTURAL.

5

LETTERING: 1/4 INCH ALUMINUM LETTERING (6” TEXT HEIGHT) AFFIXED ON THE SIDE OF THE MAIN SUPPORT - CENTERED WITH POST AND PANEL HEIGHT. FONT: DDC HARDWARE.

6

BASE: CONNECTION TO FOUNDATION WITH NCDOT BREAKAWAY SYSTEM (TRANSPO OR EQUAL) SEE STRUCTURAL DRAWINGS .

FINISHES PALETTE: P1

“BURNT RUST” POWDER COAT (PTB 6884/TEXTURE): POLYURETHANE TEXTURE POWDER COAT WITH FLAT FINISH BY PRISMATIC POWDERS.

P2

“STAINLESS”: BRUSHED ALUMINUM WITH CLEAR COAT PROTECTION.

P3

BLUE MATTHEW’S PAINT: COLOR MATCH TO PANTONE 3035 C. SUBSTRATE SHOULD BE PRIMED PRIOR TO TOPCOAT. SATIN FINISH.

VINYL SHEETING: V1

REFLECTIVE 3MTM 3930 HIGH INTENSITY PRISMATIC SHEETING: TO BE PRINTED WITH APPROVED 3M MCS PRINTING METHODS.

V2

3M SCOTCHCAL GRAPHIC FILM IJ3650: TO BE PRINTED WITH APPROVED 3M MCS PRINTING METHODS.

NOTES: ALL ATTACHMENT HARDWARE MADE INCONSPICUOUS, PAINTED TO MATCH ATTACHMENT SURFACE.

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

MAJOR WAYFINDING (STANDARD)

E-3


FABRICATION COMPONENTS:

create with us

1

POST: TWO (2) 12” X 4” X 1/4” ALUMINUM POSTS TO FORM “L” SHAPE

2

DESTINATION PANEL: 1/4 INCH ALUMINUM SHEET WITH 3MTM 3930 HIGH INTENSITY PRISMATIC SHEETING APPLIED ON RAW SURFACE. EDGE AND BACK TO HAVE MATTHEWS PAINT.

3

BACK DESTINATION PANEL: 1/4 INCH ALUMINUM WITH 3M SCOTCHAL GRAPHIC FILM IJ3650 APPLIED ON RAW SURFACE. EDGE OF SHEET TO HAVE MATTHEWS PAINT.

4

PANEL SUPPORT: 4” X 4” X 1/4” STEEL FRAME (4’W X 5.5’H 3 SIDED RECTANGLE) WELDED TO SIDE OF MAIN SUPPORT WITH HOLES FOR PANEL ATTACHMENT. SEE STRUCTURAL.

5

LETTERING: 1/4 INCH ALUMINUM LETTERING (6” TEXT HEIGHT) AFFIXED ON THE SIDE OF THE MAIN SUPPORT - CENTERED WITH POST AND PANEL HEIGHT. FONT: DDC HARDWARE.

6

BASE: CONNECTION TO FOUNDATION WITH NCDOT BREAKAWAY SYSTEM (TRANSPO OR EQUAL) SEE STRUCTURAL DRAWINGS .

7

LOCAL CREATOR ACCENTS SPACE: METAL DETAILS ON TOP AND BOTTOM OF DESTINATION PANEL. ATTACHED TO SIDE OF MAIN SUPPORT AND TOP/BOTTOM OF PANEL SUPPORT. TOP DETAIL NOT TO EXCEED 5’ W X 1’6” H. BOTTOM DETAIL NOT TO EXCEED 4’ W X 1’H.

FINISHES PALETTE: P1

“BURNT RUST” POWDER COAT (PTB 6884/TEXTURE): POLYURETHANE TEXTURE POWDER COAT WITH FLAT FINISH BY PRISMATIC POWDERS.

P2

“STAINLESS”: BRUSHED ALUMINUM WITH CLEAR COAT PROTECTION.

P3

BLUE MATTHEW’S PAINT: COLOR MATCH TO PANTONE 3035 C. SUBSTRATE SHOULD BE PRIMED PRIOR TO TOPCOAT. SATIN FINISH.

VINYL SHEETING: V1

REFLECTIVE 3MTM 3930 HIGH INTENSITY PRISMATIC SHEETING: TO BE PRINTED WITH APPROVED 3M MCS PRINTING METHODS.

V2 3M SCOTCHCAL GRAPHIC FILM IJ3650: TO BE PRINTED WITH APPROVED 3M MCS PRINTING METHODS.

NOTES: ALL ATTACHMENT HARDWARE MADE INCONSPICUOUS, PAINTED TO MATCH ATTACHMENT SURFACE.

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

MINOR WAYFINDING (LOCAL CREATOR)

E-4


FABRICATION COMPONENTS:

create with us

1

POST: TWO (2) 12” X 4” X 1/4” ALUMINUM POSTS TO FORM “L” SHAPE

2

DESTINATION PANEL: 1/4 INCH ALUMINUM SHEET WITH 3MTM 3930 HIGH INTENSITY PRISMATIC SHEETING APPLIED ON RAW SURFACE. EDGE AND BACK TO HAVE MATTHEWS PAINT.

3

BACK DESTINATION PANEL: 1/4 INCH ALUMINUM WITH 3M SCOTCHAL GRAPHIC FILM IJ3650 APPLIED ON RAW SURFACE. EDGE OF SHEET TO HAVE MATTHEWS PAINT.

4

PANEL SUPPORT: 4” X 4” X 1/4” STEEL FRAME (4’W X 5.5’H 3 SIDED RECTANGLE) WELDED TO SIDE OF MAIN SUPPORT WITH HOLES FOR PANEL ATTACHMENT. SEE STRUCTURAL.

5

LETTERING: 1/4 INCH ALUMINUM LETTERING (6” TEXT HEIGHT) AFFIXED ON THE SIDE OF THE MAIN SUPPORT - CENTERED WITH POST AND PANEL HEIGHT. FONT: DDC HARDWARE.

6

BASE: CONNECTION TO FOUNDATION WITH NCDOT BREAKAWAY SYSTEM (TRANSPO OR EQUAL) SEE STRUCTURAL DRAWINGS .

FINISHES PALETTE: P1

“BURNT RUST” POWDER COAT (PTB 6884/TEXTURE): POLYURETHANE TEXTURE POWDER COAT WITH FLAT FINISH BY PRISMATIC POWDERS.

P2

“STAINLESS”: BRUSHED ALUMINUM WITH CLEAR COAT PROTECTION.

P3

BLUE MATTHEW’S PAINT: COLOR MATCH TO PANTONE 3035 C. SUBSTRATE SHOULD BE PRIMED PRIOR TO TOPCOAT. SATIN FINISH.

VINYL SHEETING: V1

REFLECTIVE 3MTM 3930 HIGH INTENSITY PRISMATIC SHEETING: TO BE PRINTED WITH APPROVED 3M MCS PRINTING METHODS.

V2

3M SCOTCHCAL GRAPHIC FILM IJ3650: TO BE PRINTED WITH APPROVED 3M MCS PRINTING METHODS.

NOTES: ALL ATTACHMENT HARDWARE MADE INCONSPICUOUS, PAINTED TO MATCH ATTACHMENT SURFACE.

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

MINOR WAYFINDING (STANDARD)

E-5


DESIGN CRITERIA

SOIL EXCAVATION NOTES

SUBMITTALS

1.

2018 NORTH CAROLINA STATE BUILDING CODE:

1.

EXCAVATION OF THE FOOTINGS ARE TO THE DEPTHS REQUIRED AND INDICATED ON PLANS.

THE FOLLOWING COMPONENTS SHALL BE SUBMITTED TO THE

2.

ASCE 7-10

ANY OVER-EXCAVATION OF UNSUITABLE MATERIALS MAY BE NECESSARY BELOW FOOTING

STRUCTURAL ENGINEER OF RECORD FOR REVIEW AND APPROVAL:

3.

DESIGN LOADS

DEPTH. BACKFILL USING No. 57 STONE IN UNIFORM LIFTS COMPACTED TO 95% OF THE DRY

1.

STRUCTURAL STEEL SHOP FRAWING.

O

DEAD LOAD = SELF WEIGHTS

DENSITY TO RE-ESTABLISH FOOTING SUB-GRADE.

2.

NCDOT APPROVED BREAK AWAY ANCHORS.

O

GROUND SNOW LOAD = 30 PSF

USE OF A SMOOTH EDGE BUCKET IS RECOMMENDED TO EXCAVATE FOR FOOTINGS. TOOTHED

3.

CONCRETE MIX DESIGNS

O

ULTIMATE WIND VELOCITY = 115 MPH

BUCKETS MAY ALLOW BEARING SOILS TO PERFORM INEFFECTIVELY AND ALLOW WATER TO

O

BASE WIND VELOCITY = 90 MPH

SATURATE THE FOUNDATION SUB-GRADE.

O

EXPOSURE CATEGORY = C

3.

SOILS SHALL BE DETERMINED TO HAVE 2,000-PSF NET ALLOWABLE BEARING CAPACITY.

O

ASSUMED GROUND BEARING CAPACITY 2-FT BELOW GRADE: 2,000 PSF

4.

FOOTINGS ARE TO BE PLACED WITH A MINIMUM DEPTH FROM FINISHED GRADE TO BEARING

O

ALL BOTTOM OF FOOTINGS SHALL BE CAST A MINIMUM OF 2-FEET BELOW ORIGINAL 5.

Blowing Rock, NC 28605

THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING AND PROTECTING FOUNDATION

OVER-SATURATION. CARE IS TO BE TAKEN TO REMOVE AND REPLACE BEARING SOILS WITH UNIFORM LIFTS OF No. 57 STONE AS NEEDED, COMPACTED TO 95% OF THE DRY DENSITY. 6.

ONCE THE FOOTINGS ARE ABLE TO HANDLE LATERAL LOADING, BACKFILL WITH ENGINEERED

2.

THE CONTRACTOR SHALL COORDINATE HIS WORK ACTIVITIES WITH THE OWNER.

STONE OR No. 57 STONE IN UNIFORM LIFTS. EXTERIOR OF THE FOOTING MAY BE BACKFILLED

3.

CONTRACTOR SHALL MAKE A CAREFUL INSPECTION OF THE SITE TO FAMILIARIZE HIM/HERSELF WITH THE

WITH UNIFORM LIFTS OF SUITABLE SOILS COMPACTED TO 95% OF THE DRY DENSITY BEYOND

ACTUAL CONDITIONS OF THE SITE.

THE PLACEMENT OF THE FOOTING DRAIN. 7.

AND REPORT ANY INACCURACIES TO THE ENGINEER.

DRAWINGS

ROD

PLACEMENT OF THE FLOOR INSULATION AND ANY CONCRETE SLAB-ON-GRADE. AREAS OF EXCAVATION MAY BE NECESSARY TO REMOVE UNSUITABLE MATERIALS PRIOR TO

11.

THE DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT

2.

THE STRUCTURE DURING CONSTRUCTION. 12.

CONCRETE CONSTRUCTION SHALL COMPLY WITH ACI 301 "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR

(LATEST EDITION), AND ACI 302"GUIDE FOR CONCRETE FLOOR AND SLAB CONSTRUCTION" (LATEST EDITION).

BUILDING ANCHOR BOLTS TO BE ASTM F1554, GR. 36, UNLESS NOTED OTHERWISE.

5.

HEADED STUDS TO BE ASTM A108, GR. 1010 THROUGH 1020 AND SHALL MEET THE

STEEL" AWS D1.1). 6.

GROUT FOR COLUMN BASE PLATES AND PRESET BEARING PLATED SHALL BE NON-SHRINK, NON-METALLIC GROUT WITH MINIMUM F'C = 5,000 PSI.

7.

BEAM CONNECTIONS SHALL BE AS SHOWN OR NOTED ON DRAWINGS.ECCENTRIC OR ONE-

DRAWINGS. CONNECTIONS AND DETAILS ARE SUBJECT TO ENGINEER'S APPROVAL.

MINIMUM CEMENT CONTENT = 500 LBS PER CUBIC YARD.

8.

ALL STRUCTURAL STEEL MEMBERS AND SHAPES EXPOSED TO THE EXTERIOR SHALL BE HOTDIPPED GALVANIZED AS FOLLOWS:

CONCRETE SHALL BE NORMAL WEIGHT CONCRETE AND SHALL DEVELOP A MINIMUM COMPRESSIVE

A. ALL NUTS, BOLTS AND WASHERS:

STRENGTH OF 3,000 PSI AT 28 DAYS. 6.

MAXIMUM SLUMP = 4" PLUS OR MINUS 1".

7.

THE MAX AGGREGATE SIZE SHALL BE 3/4".

8.

CONCRETE AGGREGATES SHALL COMPLY WITH ASTM C33 AND SHALL BE FREE OF CLAY, FOAM, LUMPS OR

ASTM A153, CLASS C OR D (DEPENDING ON SIZE)

B. ALL OTHER STEEL ITEMS: 9.

ANCHOR BOLTS, BASE PLATES AND BEARING PLATES SHALL BE LOCATED AND BUILT INTO

SET IN FULL BEDS OF NON-SHRINK GROUT. ALL POCKETS FOR COLUMNS AND BEAMS MUST

REINFORCING BARS SHALL BE DEFORMED AND CONFORMING TO ASTM A615, GRADE 60.

BE COMPLETELY FILLED WITH SOLID MASONRY AND/OR GROUT.

10.

WELDED WIRE FABRIC SHALL CONFORM TO ASTM A1064 AND BE SUPPLIED IN SHEETS, NOT ROLLS, U.N.O.

11.

CONCRETE SHALL BE AIR ENTRAINED WITH 6% AVERAGE AIR CONTENT WITH A 1.5% TOLERANCE. AIR

10.

ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS USING MATCHING WELD METAL IN CONFORMANCE WITH LATEST EDITION OF A.W.S. D1.1.

ENTRAINMENT SHALL COMPLY WITH ASTM C260.

11.

ALL STRUCTURAL STEEL SHALL BE FABRICATED IN SHOP.

12.

REINFORCEMENT LAP SPLICES SHALL BE 44 TIMES THE BAR DIAMETER UNLESS OTHERWISE NOTED.

12.

DO NOT MODIFY STRUCTURAL STEEL IN FIELD. RETURN ANY STEEL NOT PROPERLY DETAILED

13.

REINFORCEMENT COVER SHALL BE 3" WHEN POURED ADJACENT TO GROUND SURFACE AND 1.5" ELSEWHERE,

CONCRETE SHALL BE CONSOLIDATED USING CONCRETE VIBRATOR IN ACCORDANCE WITH 309R-05.

AB AFG

ANCHOR BOLT

LLH

LONG LEG HORIZONTAL

ABOVE FINISH GRADE

LLV

LONG LEG VERTICAL

ALUM

ALUMINUM

MAX

MAXIMUM

ARCH

ARCHITECTURAL, ARCHITECTURE

MIN

MINIMUM

B/O

BY OTHERS

CL

KO

KNOCK-OUT

CENTER LINE

NTS

NOT TO SCALE

CLR

CLEAR

O/C

ON CENTER

CONTROL JOINT

OD

OUTSIDE DIAMETER

CONNECTING WORK, PRE-SET BY TEMPLATES OR SIMILAR METHODS. ALL PLATES SHALL BE

9.

U.N.O.

ABBREVIATIONS

ASTM A123

OTHER DELETERIOUS SUBSTANCES.

14.

SCALE: 3" = 1'-0"

REQUIREMENTS OF THE AMERICAN WELDING SOCIETY, "STRUCTURAL WELDING CODE -

DETAILING OF CONCRETE REINFORCEMENT" (LATEST EDITION). MIX DESIGN SHALL BE IN ACCORDANCE WITH ACI 318 (CURRENT EDITION).

TYPICAL SIGN TO FRAME CONNECTION

SIZE BOLT USED, UNLESS NOTED OTHERWISE.

SIDED CONNECTIONS WILL NOT BE PERMITTED UNLESS APPROVED AND INDICATED ON

4.

1 S1

BOLTED CONNECTIONS TO USE A 325X BOLTS, UNLESS NOTED OTHERWISE,BOLT HOLES IN

REINFORCING STEEL SHALL BE FABRICATED AND PLACED IN COMPLIANCE WITH ACI 315 "DETAILS AND

3.

5.

ASTM A53, GR. B. (FY = 35 KSI)

SHOP AND FIELD WELDS TO USE E70XX ELECTRODES. MINIMUM FILLET WELD SIZE TO BE

4.

BUILDINGS" (LATEST EDITION), ACI 318 "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE"

2.

ASTM A500. GR. B. (FY = 42 KSI)

E. PIPE

STEEL EXCEPT IN BASE PLATES SHALL BE 1/16 INCH LARGER IN DIAMETER THAN THE NORMAL

CONCRETE NOTES 1.

D.HSS-ROUND

REQUIRED. WELD SIZE SHALL BE AISC MINIMUM UNLESS A LARGER SIZE IS NOTED. 3.

AND DETAILS WITHIN STRUCTURAL DOCUMENTS. ALL SECTIONS AND DETAILS ARE NOT COMPLETE

WITH VIEWS OF OTHER SECTIONS, PLANS AND DETAILS MAY BE REQUIRED TO COMPLETE ASSEMBLY.

ASTM A500, GR. B. (FY = 46 KSI)

(AWS D1.1). WELD LENGTH SCALED FOR ON PLANS ARE THE NET EFFECTIVE LENGTH

IS RESPONSIBLE FOR COORDINATION OF ALL DETAILS WITH OTHER TRADES, DISCIPLINES AND ALL SECTIONS

REPRESENTATIONS OF CONDITIONS BUT ARE SPECIFIC TO ITEMS INDICATED IN DETAILS. COORDINATION

(FY = 36 KSI)

C. HSS-RECTANGULAR

WITH THE AMERICAN WELDING SOCIETY'SCODE FOR WELDING IN BUILDING CONSTRUCTION

SECTIONS AND DETAILS SHOWN AT LOCATIONS INDICATED ON PLAN ARE TYPICAL FOR OTHER SIMILAR CONDITIONS OF BUILDING EVEN IF NO SECTION CUT IS INDICATED AT A SIMILAR CONDITION. CONTRACTOR

(FY = 50 KSI)

ASTM A36

3/16", UNLESS NOTED OTHERWISE. ALL WELDS SHALL BE PREQUALIFIED IN CONFORMITY

APPLY TERMITE TREATMENT TO GROUND SURFACES WITHIN THE DEFINED SCOPE OF WORK AS REQUIRED BY CODE AND LOCAL BUILDING INSPECTOR.

13.

ASTM A992

B. ANGLE, CHANNEL, & PLATE

OR FABRICATED TO FABRICATOR. 13.

ALL STRUCTURAL STEEL SHALL RECEIVE ONE SHOP COAT OF FABRICATORS STANDARD SHOP PRIMER.

CJ

CONCRETE MASONRY UNIT

PSF

POUNDS PER SQUARE FOOT

CONN

CMU

CONNECTION, CONNECT

PSI

POUNDS PER SQUARE INCH

CONT

CONTINUOUS

DWG

DRAWING, DRAWINGS

SOG

SLAB-ON-GRADE

ENG

ENGINEER, ENGINEERING

STD

STANDARD

EQ

EQUAL

SST

SIMPSON STRONG TIE

FC

REINF

REINFORCEMENT, REINFORCING

COMPRESSIVE STRENGTH

TBD

TO BE DECIDED

FDN

FOUNDATION

T/O

TOP OF

TYP

TYPICAL

FY

YIELD STRESS

GC

GENERAL CONTRACTOR

UNO

UNLESS NOTED OTHERWISE

GN

GENERAL NOTES

WWF

WELDED WIRE FABRIC

GR

GRADE

Ø

DIAMETER

SHEET INDEX S1

COVER SHEET AND GENERAL NOTES

S2

STANDARD SIGN POST AND FRAME ELEVATIONS

S3

LOCAL CREATOR SIGN POST AND FRAME DETAILS

S4

SIGN POST AND FRAME DETAILS

S5

SIGN POST FOUNDATION DETAILS

SHEET NUMBER

S1

AS NOTED

WITH THE WORK.

A. W-SECTION

SCALE

DETAILS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER, AND RESOLVED BEFORE PROCEEDING

2963

OMISSIONS OR CONFLICTS BETWEEN VARIOUS ELEMENTS OF THE DRAWINGS, SPECIFICATIONS, NOTES AND

TYP.

WALL, TYP.

FOLLOWING ASTM STANDARDS:

NEW AND EXISTING STRUCTURES AND FOUNDATIONS UNTIL CONSTRUCTION IS COMPLETE. 10.

ALL STEEL SECTIONS SHALL BE PRODUCED DOMESTICALLY AND CONFORM TO THE

PROJECT No.

1.

GENERAL CONTRACTOR SHALL DESIGN AND INSTALL ALL TEMPORARY SHORING REQUIRED TO STABILIZE

LENOIR, NC

9.

SS BARRIER BOLT, 1/4" HSS

BPM

FOUNDATION LAYOUT AND FABRICATION OF ANY STRUCTURAL MEMBERS.

APPROVED BY

CONTRACTOR SHALL COORDINATE ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO

MULTIPLE LOCATIONS

8.

STRUCTURAL STEEL

BPM

1-1/2" LONG 1/4"-20

MASONRY PRIOR TO PLACEMENT.

REVIEWED BY

TAMPER RESISTANT

ELEVATION.

DEPRESSIONS, BOLTS, SLEEVES, ANCHORS, INSERTS, OPENINGS, ETC. TO BE SET OR CAST IN CONCRETE OR

AT

LIFTS OF No. 57 STONE COMPACTED TO 95% OF THE DRY DENSITY UP TO SUB-GRADE

CONTRACTOR SHALL COORDINATE AND VERIFY THE SIZE, LOCATION, TYPE, AND DIRECTION OF ALL PADS,

GT

PLACING THE VAPOR BARRIER: EXCAVATE AND REPLACE UNSUITABLE SOILS WITH UNIFORM

GOVERN.

DRAWN BY

9.

APPLICABLE ASTM STANDARDS, IN CASES OF CONFLICT, THE MOST STRINGENT REQUIREMENT SHALL

DESTINATION BY DESIGN

7.

A 6 MIL VAPOR BARRIER IS TO BE PLACED OVER THE ENTIRETY OF THE SUB-BASE, PRIOR TO

DATE

THE AISC CODE, THE ACI BUILDING CODE (ACI 318), THE AMERICAN WELDING SOCIETY CODE AND ALL

8.

REVISIONS

ALL WORK SHALL CONFORM TO THE CURRENT EDITIONS OF THE NORTH CAROLINA STATE BUILDING CODE,

THREADED

STONE IS TO BE PLACED PRIOR TO ANY CONCRETE SLAB-ON-GRADE.

6.13.2022 No.

CONTRACTOR SHALL COORDINATE THESE STRUCTURAL DRAWINGS WITH DRAWINGS OF OTHER DISCIPLINES.

6.

TYP., SEE DESIGN INTENT

A UNIFORM 8-IN. LIFT OF SUB-BASE, No. 57 STONE OR AN ENGINEERED APPROVED ALTERNATE

DATE

5.

WITH GRAPHIC FILM, 1/4"-20 SS

FOR

CONTRACTOR SHALL CHECK AND VERIFY GIVEN DIMENSIONS, TAKE ADDITIONAL DIMENSIONS AS REQUIRED

1/4" ALUMINUM SHEET

STRUCTURAL DRAWINGS

4.

FIRM LICENSE No. P-1357

BEARING SOILS FROM DISTURBANCE AND DAMAGE DURING CONSTRUCTION AND FROM

CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING EXISTING UNDERGROUND UTILITIES IN THE AREA OF CONSTRUCTION.

P.O. Box 745

HSS

OF NOT LESS THAN 24-INCHES.

GENERAL NOTES 1.

ARETÉ ENGINEERS, PLLC 7668 Valley Blvd.

4"

LENOIR WAYFINDING SIGNAGE COVER SHEET AND GENERAL NOTES

GROUND LINE. NO FOOTINGS SHALL BE CAST ON FILL MATERIAL.

2.


1/4" CAP PLATE

5'-10" 4'-6"

5'-10" 1'-4"

1'-0"

1'-4"

4'-6"

1'-0" ARETÉ ENGINEERS, PLLC 7668 Valley Blvd.

1'-6"

1'-6"

1'-6"

4"

P.O. Box 745 Blowing Rock, NC 28605

1

DATE 3 S4

REAR SIDE

LEFT SIDE

FRONT SIDE

RIGHT SIDE

2 S2

MAJOR WAYFINDING (STANDARD) - SIGN POST AND FRAME SCALE: 1/4" = 1'-0"

S2

AS NOTED

2963

SCALE

PROJECT No.

APPROVED BY

BPM

REVISIONS SHEET NUMBER

LENOIR, NC

8'-0"

S4

8'-0"

2

MULTIPLE LOCATIONS

SCALE: 1/4" = 1'-0"

14'-11 1/8 "

15'-6"

MAJOR WAYFINDING (STANDARD) - SIGN POST AND FRAME

7'-5"

1 S2

BPM

1'-6"

1'-6" 1 S4

REVIEWED BY

RIGHT SIDE

6'-0"

FRONT SIDE

6'-0"

1'-6" LEFT SIDE

6'-0"

REAR SIDE

AT

4"

S4

GT

1'-0"

DRAWN BY

4'-0"

DESTINATION BY DESIGN

1'-4"

6.13.2022 No.

1'-0"

DATE

1'-4"

FRAME ELEVATIONS

4'-0"

3

5'-4"

STRUCTURAL DRAWINGS

5'-4"

LENOIR WAYFINDING SIGNAGE

8'-0"

8'-0"

7'-5"

1/4" CAP PLATE

STANDARD SIGN POST AND

2 S4

FOR

16'-0"

15'-5 1/8 "

S4

6'-6"

6'-6"

6'-6"

FIRM LICENSE No. P-1357


1/4" CAP PLATE

5'-10" 4'-6"

5'-10" 1'-4"

1'-0"

1'-4"

4'-6"

1'-0" ARETÉ ENGINEERS, PLLC 7668 Valley Blvd.

LOCAL CREATOR

1'-6"

1'-6"

4"

P.O. Box 745

CONNECTION POINT,

Blowing Rock, NC 28605

SEE DETAIL 6/S2

1

8'-0"

S4

8'-0"

2

3 S4

REAR SIDE

LEFT SIDE

FRONT SIDE

RIGHT SIDE

DATE

2 S3

MAJOR WAYFINDING (LOCAL CREATOR) - SIGN POST AND FRAME SCALE: 1/4" = 1'-0"

S3

AS NOTED

2963

SCALE

PROJECT No.

APPROVED BY

BPM

REVISIONS SHEET NUMBER

LENOIR, NC

SCALE: 1/4" = 1'-0"

14'-11 1/8 "

15'-6"

MAJOR WAYFINDING (LOCAL CREATOR) - SIGN POST AND FRAME

7'-5"

1 S3

BPM

1'-6" 1 S4

MULTIPLE LOCATIONS

RIGHT SIDE

6'-0"

FRONT SIDE

6'-0"

1'-6" LEFT SIDE

6'-0"

REAR SIDE

REVIEWED BY

4"

S4

AT

1'-0"

GT

4'-0"

DRAWN BY

1'-4"

DESTINATION BY DESIGN

1'-0"

6.13.2022 No.

1'-4"

DATE

4'-0"

3

5'-4"

FOR

SEE DETAIL 6/S2 5'-4"

POST AND FRAME ELEVATIONS

8'-0"

8'-0"

7'-5"

CONNECTION POINT,

STRUCTURAL DRAWINGS

LOCAL CREATOR 1/4" CAP PLATE

LOCAL CREATOR STANDARD SIGN

2 S4

LENOIR WAYFINDING SIGNAGE

16'-0"

15'-5 1/8 "

S4

6'-6"

6'-6"

6'-6"

FIRM LICENSE No. P-1357


4 S4

VARIES (SEE ELEVATIONS) 6"

EQUAL

EQAL

EQUAL

6"

1/4" CAP ARETÉ ENGINEERS, PLLC 7668 Valley Blvd.

PLATE GRIND FLUSH

6"

4" HSS12X4X1/4, POST

TOP OF

P.O. Box 745

POST

6-12 3"

Blowing Rock, NC 28605 FIRM LICENSE No. P-1357

GRIND

EQUAL

FLUSH

1'-0"

POST

HSS4X4X1/4 1'-6"

HSS12X4X1/4,

SIGN POST

HSS4X4X1/4, SEE SIGN FRAME DETAIL

EQUAL 6"

POST

18"

1" THICK STEEL

4

TYP.

S4 2 S4

TYPICAL SIGN FRAME SCALE:

5

1" = 1'-0"

S4

SIGN POST L.C CONNX. SCALE:

1 1/2" = 1'-0"

HSS4X4X1/4 SIGN FRAME (4) 1 1/8"Ø 1/4

BOLT HOLES

4"

1 1/2 "

PLATE

(4) 1/2-13 WELD NUTS 3"

EQUAL

EQUAL

EQUAL

3"

EVENLY SPACED AS SHOWN PROVIDE

4'-0" OR 4'-6"

AT WELD NUT 3 S4

TYPICAL SIGN POST BASE PLATE SCALE:

1 1/2" = 1'-0"

4 S4

SIGN FRAME LOCAL CREATOR (L.C) CONNECTIONS SCALE:

1 1/2" = 1'-0"

LOCATIONS

S4

AS NOTED

2963

SCALE

PROJECT No.

BPM

BPM

SHEET NUMBER

5/8"Ø HOLES IN HSS

LENOIR, NC

HSS12X4X1/4 SIGN

APPROVED BY

1'-0"

TYP.

1 1/2 "

BUILT-UP (2)

MULTIPLE LOCATIONS

TYP.

STRUCTURAL DRAWINGS

TYP.

EQUAL

1 1/2 "

REVIEWED BY

LOCATIONS 1 1/2 "

DATE

3"

POST AT NUT

AT

5/8" HOLES IN 18"

GT

NUTS WHERE SHOWN. PROVIDE

DRAWN BY

(4) 1/2-13 WELD

TYP.

FOR

HSS4X4X1/4,

DESTINATION BY DESIGN

SEE DETAIL

6.13.2022 No.

HSS4X4X1/4 SIGN FRAME,

DETAIL 1/S1

FRAME ELEVATIONS

SIDES OF HSS FOR SIGN CONNECTION, TYP., SEE

SIGN POST AND

SCALE: 1 1/2" = 1'-0"

3/8"Ø HOLT THRU BOTH

LENOIR WAYFINDING SIGNAGE

TYPICAL POST WELDMENT

EQUAL

S4

VARIES (SEE ELEVATIONS)

1

FLUSH

DATE

GRIND 8-12


(8) #4 REBAR EQUALLY SPACED AS SHOWN ARETÉ ENGINEERS, PLLC 7668 Valley Blvd.

BUILT-UP SIGN #4 TIES AT 12" O/C

POST, SEE DETAILS

P.O. Box 745

(4) 1"Ø ANCHOR

Blowing Rock, NC 28605

BOLTS, SEE DETAIL

FIRM LICENSE No. P-1357 CYLINDRIAL CONCRETE

HEAVY HEX NUT BOTTOM AND SIDE OF 2'-6" DIAMETER

WITH JAM NUT

FOUNDATION SHALL BE CAST AGAINST RESIDUAL GRADE, NOT FILL

SHEET NUMBER 1 S5

TYPICAL SIGN FOUNDATION SCALE: 1" = 1'-0"

3 S5

TYPICAL ANCHOR BOLT DETAIL SCALE: 1 1/2" = 1'-0"

S5

AS NOTED

2963

SCALE

PROJECT No.

LENOIR, NC

BPM APPROVED BY

BPM

GT

REVISIONS

FOR

STRUCTURAL DRAWINGS

3" CLR.

LENOIR WAYFINDING SIGNAGE

24" 3" CLR.

3" CLR.

EMBEDMENT

DATE

ANCHOR BOLTS

MULTIPLE LOCATIONS

1"Ø F1554 GR.55

REVIEWED BY

ANCHOR

AT

BREAK-A-WAY

DRAWN BY

NCDOT APPROVED

DESTINATION BY DESIGN

5'-6" MIN.

1" THICK BASE PLATE

6.13.2022 No.

3" MIN.

S5

DETAILS

SCALE: 1" = 1'-0"

SIGN POST FOUNDATION

TYPICAL FOUNDATION SECTION

2 S5

2

DATE

FINISHED GRADE

FOUNDATION


Citywide Wayfinding Map

3

1

FIELD NOTES:

19 2

4

21 18

5

17 12

(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

£ ¤

15

321

N

WAYFINDING SYSTEM

16

Legend #

0

(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.

13

14

(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.

20 6-11

NOTES:

1

Project #: Drawn By: Checked By: Scale: Varies

Client:

Sign

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

2

Issue 1

136 Furman Rd.

Miles These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

USGS USGSThe TheNational NationalMap: Map:3D 3DElevation ElevationProgram. Program.USGS USGSEarth EarthResources ResourcesObservation Observation&&Science Science(EROS) (EROS) Center: GMTED2010. Data refreshed March, 2019. Center: GMTED2010. Data refreshed March, 2019.

Date June 2022

G-1


Citywide Wayfinding Matrix

CODE

SIGN TYPE

PRIMARY STREET

CROSS STREET

DIRECTION

SITE CONTENTS FRONT

SPEED LIMIT

45

1a

Major

HWY 321

North Main St

Southbound

S_Soccer Complex (GW)(MTN) S_Greenway (GW) R_Downtown

1b

Major

North Main St

HWY 321

Northbound

R_Aquatic Center (GW)(MTN) R_Soccer Complex (GW)(MTN) R_Greenway (GW)

45

L_Downtown L_JE Broyhill Park L_Community Gardens (GW)

45

1c

2a

2b

Major

Major

Major

HWY 321

Nuway Circ

HWY 321

North Main St

HWY 321

Greenhaven Dr & Nuway Cir

Northbound

Southbound

S_Downtown S_MLK Rec Center L_Library (GW)

Southbound

L_Greenway GW) L_Aquatic Center (GW)(MTN) R_MLK Rec Center

FIELD NOTES:

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

35

45

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

2c

Minor

Greenhaven Dr

HWY 321

Northbound

S_Aquatic Center (GW)(MTN) S_Greenway (GW) R_Soccer Complex (GW)(MTN)

2d

Major

HWY 321

Nuway Circ

Northbound

L_MLK Rec Center R_Aquatic Center (GW)(MTN) R_Soccer Complex (GW)(MTN)

45

3a

Major

Zack’s Fork Rd

HWY 321

Westbound

L_Downtown L_MLK Rec Center L_Greenway (GW)

35

25

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

WAYFINDING SYSTEM Project Project #: #: Drawn Drawn By: By: Checked Checked By: By: Scale: Scale: Varies Varies Issue Issue 11

Client: Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200 136 136 Furman Furman Rd. Rd.

These These drawings drawings are are meant meant for for DESIGN DESIGN INTENT INTENT ONLY. ONLY. Shop Shop drawings drawings and and details details must must be be submitted submitted to to this this office office for for approval approval prior prior to to fabrication. fabrication.

Date Date June June 2022 2022

Boone, Boone, NC NC 28607 28607 Ph: Ph: 828.386.1866 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-2


Citywide Wayfinding Matrix

CODE

SIGN TYPE

PRIMARY STREET

CROSS STREET

DIRECTION

SITE CONTENTS FRONT

SPEED LIMIT

3b

Major

Nuway Cir

Zack’s Fork Rd

Northbound

R_Mtn Bike Trails (MTN) R_Soccer Complex (GW)(MTN)

35

4a

Major

North Main St

North Main St

Southbound

S_Community Gardens (GW) L_Downtown L_JE Broyhill Park

45

S_Soccer Complex (GW)(MTN) S_Greenway (GW) R_JE Broyhill Park

45

4b

4c

5a

Major

Major

Minor

Creekway Dr

North Main Street

North Main St

North Main St

Creekway Dr/North Main St

Finley Ave

Northbound

Northbound

L_Community Gardens (GW) R_Aquatic Center (GW)(MTN) R_Soccer Complex (GW)(MTN)

Southbound

S_Downtown L_Freedman Center L_MLK Rec Center

FIELD NOTES:

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

35

20

(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

5b

Minor

North Main St

Finley Ave

Northbound

R_Freedman Center R_MLK Rec Center R_Aquatic Center (GW)(MTN)

5c

Minor

Finley Ave

North Main St

Westbound

L_Downtown L_Walker Stadium L_The Campus (GW)

25

6a

Minor

Harper Ave

Westbound

R_Downtown R_JE Broyhill Park R_The Campus (GW)

20

Norwood St/Ridge St

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.

20

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-3


Citywide Wayfinding Matrix

CODE

SIGN TYPE

PRIMARY STREET

CROSS STREET

DIRECTION

SITE CONTENTS FRONT

SPEED LIMIT

6b

Minor

Harper Ave

Norwood St/Ridge St

Eastbound

S_Greenway (GW) L_JE Broyhill Park

20

7a

Minor

Main St

Harper Ave

Southbound

S_Heritage Museum S_Walker Stadium S_The Campus (GW)

20

S_Hospital R_Walker Stadium

20

7b

7c

8a

Minor

Minor

Minor

Harper Ave

South Main St

Mulberry St

Main St/South Main St

College Ave

Harper Ave

Eastbound

Southbound

R_The Campus (GW) R_Community Gardens (GW)

Southbound

S_Hospital S_Mulberry Rec Center S_The Campus (GW)

FIELD NOTES:

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

20

20

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

8b

Minor

Harper Ave

Mulberry St

Eastbound

R_Hospital R_Mulberry Rec Center

8c

Minor

Mulberry St

College Ave

Northbound

S_Downtown L_The Campus (GW)

25

8d

Minor

Mulberry St

College Ave

Southbound

S_Hospital S_Mulberry Rec Center R_The Campus (GW)

25

25

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-4


Citywide Wayfinding Matrix

CODE

SIGN TYPE

PRIMARY STREET

CROSS STREET

DIRECTION

SITE CONTENTS FRONT

SPEED LIMIT

9

Minor

Ridge St

West Ave

Northbound

S_JE Broyhill Park L_Downtown L_The Campus (GW)

20

10

Minor

West Ave

Mulberry St

Westbound

L_Hospital L_Mulberry Rec Center L_The Campus (GW)

20

L_Heritage Museum L_Walker Stadium L_The Campus (GW)

20

11

12a

12b

Minor

Major

Major

West Ave

HWY 321

Wilkesboro Blvd

Main St

Wilkesboro Blvd

HWY 321

Westbound

Southbound

S_Visitor Center L_Civic Center R_Downtown

Eastbound

L_Greenway L_Aquatic Center (GW)(MTN) R_Visitor Center

FIELD NOTES:

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

45

45

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

12c

Major

HWY 321

Wilkesboro Blvd

Northbound

S_Aquatic Center (GW)(MTN) L_Downtown L_The Campus (GW)

12d

Major

Wilkesboro Blvd

HWY 321

Westbound

S_Downtown S_Greenway (GW) L_Visitor Center

45

13a

Minor

Mulberry St

Morganton Blvd/HWY 64

Southbound

S_Mulberry Rec Center S_TH Broyhill Walking Park (GW) S_Greenway (GW)

25

45

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-5


Citywide Wayfinding Matrix

CODE

SIGN TYPE

PRIMARY STREET

CROSS STREET

DIRECTION

SITE CONTENTS FRONT

SPEED LIMIT

13b-1

Major

Morganton Blvd/HWY 64

Mulberry St

Northbound

L_Downtown L_Hospital R_Mulberry Rec Center

45

13b-2

Major

Morganton Blvd/HWY 64

Mulberry St

Westbound

S_Aquatic Center (GW)(MTN) R_TH Broyhill Walking Park (GW) R_Greenway (GW)

45

Southbound

L_Mulberry Rec Center L_TH Broyhill Walking Park (GW) R_Downtown

45

13c

14a

14b

Major

Major

Major

Morganton Blvd/HWY 64

Creekway Dr

Harper Ave

Mulberry St

Harper Ave

Harper Ave

Southbound

L_Downtown L_The Campus (GW) L_Community Gardens (GW)

Northbound

S_Soccer Complex (GW)(MTN) R_Downtown R_Community Gardens (GW)

FIELD NOTES:

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

45

45

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

14c

Major

Harper Ave

Creekway Dr/Harper Ave

Southbound

R_Aquatic Center (GW)(MTN) R_Soccer Complex (GW)(MTN) R_Greenway (GW)

15a

Major

Harper Ave

Morganton Blvd/HWY 64

Southbound

L_Mulberry Rec Center L_TH Broyhill Walking Park (GW) L_Greenway (GW)

45

15b

Major

Morganton Blvd/HWY 64

Harper Ave

Eastbound

S_Mulberry Rec Center L_Downtown L_Soccer Complex (GW)(MTN)

50

35

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-6


Citywide Wayfinding Matrix

CODE

SIGN TYPE

PRIMARY STREET

CROSS STREET

DIRECTION

SITE CONTENTS FRONT

SPEED LIMIT

15c

Major

Harper Ave

Morganton Blvd/HWY 64

Northbound

S_Downtown S_Community Gardens (GW) R_Mulberry Rec Center

45

15d

Major

Morganton Blvd/HWY 64

Harper Ave

Westbound

R_Downtown R_Soccer Complex (GW)(MTN) R_Community Gardens (GW)

45

L_Chamber of Commerce L_Civic Center L_Visitor Center

45

16a

16b

17a

Major

Major

Major

HWY 321

HWY 321

Harper Ave

Civic Center Dr

Civic Center Dr

Morganton Blvd/HWY 64

Southbound

Northbound

S_Downtown S_The Campus (GW) L_Visitor Center

Eastbound

R_Greenway (GW) R_Mulberry Rec Center R_TH Broyhill Walking Park (GW)

FIELD NOTES:

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

45

45

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

17b

Major

Morganton Blvd/HWY 64

Harper Ave

Eastbound

L_Downtown L_The Campus (GW) R_Aquatic Center (GW)(MTN)

17c

Major

Harper Ave

Morganton Blvd/HWY 64

Westbound

S_Downtown L_Mulberry Rec Center L_TH Broyhill Walking Park (GW)

45

18a

Major

HWY 321

Hospital Ave

Southbound

L_Library (GW) R_Downtown R_The Campus (GW)

45

45

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-7


Citywide Wayfinding Matrix

CODE

SIGN TYPE

PRIMARY STREET

CROSS STREET

DIRECTION

SITE CONTENTS FRONT

SPEED LIMIT

18b

Major

HWY 321

Hospital Ave

Northbound

L_Downtown R_Library (GW) R_Greenway (GW)

45

19a

Major

Nuway Circ

Powell Rd

Southbound

S_Downtown L_Aquatic Center (GW)(MTN) L_Athletic Park (GW)

35

S_Soccer Complex (GW)(MTN) R_Aquatic Center (GW)(MTN) R_Athletic Park (GW)

35

19b

19c

20

21a

21b

Major

Minor

Minor

Major

Major

Nuway Circ

Powell Rd

Hospital Ave

Wilkesboro Blvd

Taylorsville Rd

Powell Rd

Nuway Circ

Harper Ave

Taylorsville Rd

Wilkesboro Blvd

Northbound

Westbound

L_Downtown L_MLK Rec Center R_Soccer Complex (GW)(MTN)

Southbound

R_Downtown R_JE Broyhill Park R_The Campus (GW)

FIELD NOTES:

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

25

25

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

Westbound

S_Downtown R_Aquatic Center (GW)(MTN) R_The Campus (GW)

45

Westbound

S_Aquatic Center (GW)(MTN) S_Greenway (GW) L_Downtown

35

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-8


*WILL REQUIRE 1 MINOR DIRECTIONAL SIGN ON COLLEGE AVE AND 1

Sign 1 a/b/c

ON BEALL ST

SIGN 1a SOCCER COMPLEX (GW)(MTB)

GREENWAY (GW)

Primary Street: HWY 321 Cross Street: North Main St Direction: Southbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

DOWNTOWN FIELD NOTES:

SIGN 1c Primary Street: HWY 321 Cross Street: North Main St Direction: Northbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

DOWNTOWN

JE BROYHILL PARK

*COMMUNITY GARDENS (GW)

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

SIGN 1b AQUATIC CENTER (GW)(MTB)

SOCCER COMPLEX (GW)(MTB)

GREENWAY (GW)

Primary Street: North Main St Cross Street: HWY 321 Direction: Northbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-9


Priority Placement Zone: 1 a/b/c

CLE NE WAY S ID E C IR

1a

FIELD NOTES:

£ ¤ 321

NOTES: BLO

£ ¤ 321

WIN

1c

GR OCK

BOU

(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

LEV

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.

ARD

(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

NW

1b

ET

H

ST

RE

ET

WAYFINDING SYSTEM

AB IZ EL

MAIN S TREE

T NW

(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

LEGEND:

Issue 1

136 Furman Rd.

Boone, NC 28607

Ph: 828.386.1866

PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Date June 2022

GRAPHIC LAYOUTS & LOCATIONS

G-10


Sign 2 a/b/c/d

SIGN 2a DOWNTOWN

MLK REC CENTER

Primary Street: Nuway Circ Cross Street: HWY 321 Direction: Southbound Speed Limit: 35 Sign Type: Major Letter Size: 5”

LIBRARY (GW)

SIGN 2c FIELD NOTES: Primary Street: Greenhaven Dr Cross Street: HWY 321 Direction: Northbound Speed Limit: 25 Sign Type: Minor Letter Size: 4”

AQUATIC CENTER (GW)(MTB)

MLK REC CENTER

GREENWAY (GW)

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

SOCCER COMPLEX (GW)(MTB)

SIGN 2b GREENWAY (GW)

AQUATIC CENTER (GW)(MTB)

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.

Primary Street: HWY 321 Cross Street: Nuway Circ/ Greenhaven Dr Direction: Southbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

SIGN 2d

WAYFINDING SYSTEM

MLK REC CENTER Primary Street: HWY 321 Cross Street: Nuway Circ Direction: Northbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

Project #: Drawn By: Checked By: Scale: Varies

Client:

AQUATIC CENTER (GW)(MTB)

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

SOCCER COMPLEX (GW)(MTB)

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-11


PO

E RO AD 1 523

Priority Placement Zone: 2 a/b/c/d

WE LL RO NE

S TAT

AD

2a 19b

BO

NUW

CK

UL

EV

AR

NOTES:

D

(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

£ ¤ 321

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

NW

RO

N DR IVE

G

2d

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

AV E

2b

IN

COURT

FIELD NOTES:

C E DA

ENH

OW

R RU N

GRE

BL

ELOT

AY C IRL

E NE

M CA

STRE

ET N E

2c

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

LEGEND:

Issue 1

136 Furman Rd.

Boone, NC 28607

Ph: 828.386.1866

PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Date June 2022

GRAPHIC LAYOUTS & LOCATIONS

G-12


Sign 3 a/b

SIGN 3a DOWNTOWN

MLK REC CENTER GREENWAY (GW)

Primary Street: Zack’s Fork Rd Cross Street: HWY 321 Direction: Westbound Speed Limit: 35 Sign Type: Major Letter Size: 5”

FIELD NOTES:

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

SIGN 3b Primary Street: Nuway Circ Cross Street: Zack’s Fork Rd Direction: Northbound Speed Limit: 35 Sign Type: Major Letter Size: 5”

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

MTN BIKE TRAILS (MTB)

WAYFINDING SYSTEM

SOCCER COMPLEX (GW)(MTB)

Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-13


Priority Placement Zone: 3 a/b KING SWOO CLE D CIR NE

3a

RK S FO K C ZA

ROA

D

FIELD NOTES:

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.

NU WA

(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

IRC YC LE

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

3b

NE

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

LEGEND:

Issue 1

136 Furman Rd.

Boone, NC 28607

Ph: 828.386.1866

PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Date June 2022

GRAPHIC LAYOUTS & LOCATIONS

G-14


SIGN 4a

*WILL REQUIRE 1 MINOR DIRECTIONAL SIGN ON COLLEGE AVE AND 1

Sign 4 a/b/c

ON BEALL ST

*COMMUNITY GARDENS (GW)

DOWNTOWN

Primary Street: North Main St Cross Street: North Main St Direction: Southbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

JE BROYHILL PARK FIELD NOTES:

SIGN 4c NOTES: *COMMUNITY GARDENS (GW) Primary Street: North Main St Cross Street: Creekway Dr/North Main St Direction: Northbound Speed Limit: 35 Sign Type: Major Letter Size: 5”

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.

AQUATIC CENTER (GW)(MTB)

SOCCER COMPLEX (GW)(MTB)

GREENWAY (GW)

JE BROYHILL PARK

(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

SIGN 4b SOCCER COMPLEX (GW)(MTB)

(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

Primary Street: Creekway Dr Cross Street: North Main St Direction: Northbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-15


Priority Placement Zone: 4 a/b/c

4a FIELD NOTES:

OL

D

NO

RT

H

RO

AD

NW

NOTES:

ST

AT

E

HI

GH

(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

W

AY

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

90

4c

WAYFINDING SYSTEM

AI

4b

N ST RE ET NW

E

AY

NW

M

CR

W EK

I DR

VE

Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

LEGEND:

Issue 1

136 Furman Rd.

Boone, NC 28607

Ph: 828.386.1866

PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Date June 2022

GRAPHIC LAYOUTS & LOCATIONS

G-16


Sign 5 a/b/c SIGN 5a DOWNTOWN

FREEDMAN CENTER

MLK REC CENTER

Primary Street: North Main St Cross Street: Finley Ave Direction: Southbound Speed Limit: 20 Sign Type: Minor Letter Size: 4”

FIELD NOTES:

SIGN 5c

Primary Street: Finley Ave Cross Street: North Main St Direction: Westbound Speed Limit: 25 Sign Type: Minor Letter Size: 4”

DOWNTOWN WALKER STADIUM

THE CAMPUS (GW)

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

SIGN 5b FREEDMAN CENTER MLK REC CENTER AQUATIC CENTER (GW)(MTB)

Primary Street: North Main St Cross Street: Finley Ave Direction: Northbound Speed Limit: 20 Sign Type: Minor Letter Size: 4”

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-17


Priority Placement Zone: 5 a/b/c

5a

FI

ST

RE

ET

NW

M AI N ST RE ET N W

FIELD NOTES:

E NL

Y

A

VE

NW

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.

VA

NC

E

5c

STAT E H IG H WAY 90

FIN LE Y AV E NW

(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

T NW

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

WAYFINDING SYSTEM

RIDGE

STREE

5b

Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

LEGEND:

Issue 1

136 Furman Rd.

Boone, NC 28607

Ph: 828.386.1866

PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Date June 2022

GRAPHIC LAYOUTS & LOCATIONS

G-18


Sign 6 a/b

SIGN 6a DOWNTOWN JE BROYHILL PARK THE CAMPUS (GW)

Primary Street: Harper Ave Cross Street: Norwood St/Ridge St Direction: Westbound Speed Limit: 20 Sign Type: Minor Letter Size: 4”

FIELD NOTES:

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.

SIGN 6b

Primary Street: Harper Ave Cross Street: Norwood St/Ridge St Direction: Eastbound Speed Limit: 20 Sign Type: Minor Letter Size: 4”

(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

GREENWAY (GW)

WAYFINDING SYSTEM

JE BROYHILL PARK

Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-19


Priority Placement Zone: 6 a/b

W

T ES

AV

E

RI

10

DG

6a E

ST

RE

HL

9

ET

EW IS

11

PR ICE ST

FIELD NOTES:

RE

8a

ET

R

E

NO

HA

AV

R PE

NOTES:

RW OO

6b

DS

7a

TR EE T

8b

8d

(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

RE E

WAYFINDING SYSTEM

ILL

ET

LL

AV

YH

RE

CO

E EG

OR

ST

CT

CH

RE

ET

IUR

SW

CH

ST

ET

RY

RE

ER

ST

LB

IN

7c

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.

MU

MA

7b

(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

PL AC E

Project #: Drawn By: Checked By: Scale: Varies

Client:

8c

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

LEGEND:

Issue 1

136 Furman Rd.

Boone, NC 28607

Ph: 828.386.1866

PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Date June 2022

GRAPHIC LAYOUTS & LOCATIONS

G-20


SIGN 7a HERITAGE MUSEUM

WALKER STADIUM

*THE CAMPUS (GW)

Sign 7 a/b/c

*WILL REQUIRE 2 MINOR SIGNS AT WILLOW ST & HARPER AVE **WILL REQUIRE 1 MINOR DIRECTIONAL SIGN ON COLLEGE AVE AND 1

ON BEALL ST

Primary Street: Main St Cross Street: Harper Ave Direction: Southbound Speed Limit: 20 Sign Type: Minor Letter Size: 4”

FIELD NOTES:

SIGN 7b

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

HOSPITAL

WALKER STADIUM

Primary Street: Harper Ave Cross Street: Main St/South Main St Direction: Eastbound Speed Limit: 20 Sign Type: Minor Letter Size: 4”

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

SIGN 7c

Primary Street: South Main St Cross Street: College Ave Direction: Southbound Speed Limit: 20 Sign Type: Minor Letter Size: 4”

*THE CAMPUS (GW)

**COMMUNITY GARDENS (GW)

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-21


Priority Placement Zone: 7 a/b/c

W

T ES

AV

E

RI

10

DG

6a E

ST

RE

HL

9

ET

EW IS

11

PR ICE ST

FIELD NOTES:

RE

8a

ET

R

E

NO

HA

AV

R PE

NOTES:

RW OO

6b

DS

7a

TR EE T

8b

8d

(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

RE E

WAYFINDING SYSTEM

ILL

ET

LL

AV

YH

RE

CO

E EG

OR

ST

CT

CH

RE

ET

IUR

SW

CH

ST

ET

RY

RE

ER

ST

LB

IN

7c

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.

MU

MA

7b

(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

PL AC E

Project #: Drawn By: Checked By: Scale: Varies

Client:

8c

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

LEGEND:

Issue 1

136 Furman Rd.

Boone, NC 28607

Ph: 828.386.1866

PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Date June 2022

GRAPHIC LAYOUTS & LOCATIONS

G-22


SIGN 8a HOSPITAL

MULBERRY REC CENTER

Sign 8 a/b/c/d

*WILL REQUIRE 2 MINOR SIGNS AT WILLOW ST & HARPER AVE

Primary Street: Mulberry St Cross Street: Harper Ave Direction: Southbound Speed Limit: 20 Sign Type: Minor Letter Size: 4”

*THE CAMPUS (GW)

SIGN 8c FIELD NOTES: Primary Street: Mulberry St Cross Street: College Ave Direction: Northbound Speed Limit: 25 Sign Type: Minor Letter Size: 4”

DOWNTOWN NOTES: *THE CAMPUS (GW)

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.

SIGN 8b

HOSPITAL MULBERRY REC CENTER

(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

Primary Street: Harper Ave Cross Street: Mulberry St Direction: Eastbound Speed Limit: 25 Sign Type: Minor Letter Size: 4”

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

SIGN 8d

Primary Street: Mulberry St Cross Street: College Ave Direction: Southbound Speed Limit: 25 Sign Type: Minor Letter Size: 4”

WAYFINDING SYSTEM

HOSPITAL

Project #: Drawn By: Checked By: Scale: Varies

Client:

MULBERRY REC CENTER

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

*THE CAMPUS (GW)

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-23


Priority Placement Zone: 8 a/b/c/d

W

T ES

AV

E

RI

10a

DG

6a E

ST

RE

HL

9

ET

EW IS

11

PR ICE ST

FIELD NOTES:

RE

8a

ET

10b

R

E

NO

HA

AV

R PE

NOTES:

RW OO

6b

DS

7a

TR EE T

8b

(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

MU

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

RE

7c E

WAYFINDING SYSTEM

ILL

ET

LL

AV

YH

RE

CO

E EG

OR

ST

CT

CH

RE

ET

IUR

SW

CH

ST

ET

RY

RE

ER

ST

LB

IN

7d

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.

8d

MA

7b

(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

PL AC E

Project #: Drawn By: Checked By: Scale: Varies

Client:

8c

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

LEGEND:

Issue 1

136 Furman Rd.

Boone, NC 28607

Ph: 828.386.1866

PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Date June 2022

GRAPHIC LAYOUTS & LOCATIONS

G-24


Sign 9

*WILL REQUIRE 2 MINOR SIGNS AT WILLOW ST & HARPER AVE

FIELD NOTES:

SIGN 9 NOTES: JE BROYHILL PARK DOWNTOWN *THE CAMPUS (GW)

Primary Street: Ridge St Cross Street: West Ave Direction: Northbound Speed Limit: 20 Sign Type: Minor Letter Size: 4”

(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-25


Priority Placement Zone: 9

W

T ES

AV

E

RI

10

DG

6a E

ST

RE

HL

9

ET

EW IS

11

PR ICE ST

FIELD NOTES:

RE

8a

ET

R

E

NO

HA

AV

R PE

NOTES:

RW OO

6b

DS

7a

TR EE T

8b

8d

(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

RE E

WAYFINDING SYSTEM

ILL

ET

LL

AV

YH

RE

CO

E EG

OR

ST

CT

CH

RE

ET

IUR

SW

CH

ST

ET

RY

RE

ER

ST

LB

IN

7c

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.

MU

MA

7b

(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

PL AC E

Project #: Drawn By: Checked By: Scale: Varies

Client:

8c

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

LEGEND:

Issue 1

136 Furman Rd.

Boone, NC 28607

Ph: 828.386.1866

PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Date June 2022

GRAPHIC LAYOUTS & LOCATIONS

G-26


Sign 10

*WILL REQUIRE 2 MINOR SIGNS AT WILLOW ST & HARPER AVE

SIGN 10 HOSPITAL MULBERRY REC CENTER *THE CAMPUS (GW)

Primary Street: West Ave Cross Street: Mulberry St Direction: Westbound Speed Limit: 20 Sign Type: Minor Letter Size: 4”

FIELD NOTES:

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-27


Priority Placement Zone: 10a

W

T ES

AV

E

RI

10

DG

6a E

ST

RE

HL

9

ET

EW IS

11

PR ICE ST

FIELD NOTES:

RE

8a

ET

R

E

NO

HA

AV

R PE

NOTES:

RW OO

6b

DS

7a

TR EE T

8b

8d

(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

RE E

WAYFINDING SYSTEM

ILL

ET

LL

AV

YH

RE

CO

E EG

OR

ST

CT

CH

RE

ET

IUR

SW

CH

ST

ET

RY

RE

ER

ST

LB

IN

7c

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.

MU

MA

7b

(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

PL AC E

Project #: Drawn By: Checked By: Scale: Varies

Client:

8c

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

LEGEND:

Issue 1

136 Furman Rd.

Boone, NC 28607

Ph: 828.386.1866

PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Date June 2022

GRAPHIC LAYOUTS & LOCATIONS

G-28


Sign 11

*WILL REQUIRE 2 MINOR SIGNS AT WILLOW ST & HARPER AVE

FIELD NOTES:

SIGN 11 HERITAGE MUSEUM WALKER STADIUM *THE CAMPUS (GW)

NOTES: Primary Street: West Ave Cross Street: Main St Direction: Westbound Speed Limit: 20 Sign Type: Minor Letter Size: 4”

(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-29


Priority Placement Zone: 11

W

T ES

AV

E

RI

10

DG

6a E

ST

RE

HL

9

ET

EW IS

11

PR ICE ST

FIELD NOTES:

RE

8a

ET

R

E

NO

HA

AV

R PE

NOTES:

RW OO

6b

DS

7a

TR EE T

8b

8d

(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

RE E

WAYFINDING SYSTEM

ILL

ET

LL

AV

YH

RE

CO

E EG

OR

ST

CT

CH

RE

ET

IUR

SW

CH

ST

ET

RY

RE

ER

ST

LB

IN

7c

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.

MU

MA

7b

(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

PL AC E

Project #: Drawn By: Checked By: Scale: Varies

Client:

8c

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

LEGEND:

Issue 1

136 Furman Rd.

Boone, NC 28607

Ph: 828.386.1866

PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Date June 2022

GRAPHIC LAYOUTS & LOCATIONS

G-30


Sign 12 a/b/c/d

SIGN 12a VISITOR CENTER CIVIC CENTER

DOWNTOWN

Primary Street: HWY 321 Cross Street: Wilkesboro Blvd Direction: Southbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

SIGN 12c FIELD NOTES: Primary Street: HWY 321 Cross Street: Wilkesboro Blvd Direction: Northbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

AQUATIC CENTER (GW)(MTB) DOWNTOWN

(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

THE CAMPUS (GW)

SIGN 12b

VISITOR CENTER

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.

GREENWAY (GW)

AQUATIC CENTER (GW)(MTB)

NOTES:

(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

Primary Street: Wilkesboro Blvd Cross Street: HWY 321 Direction: Eastbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

WAYFINDING SYSTEM

SIGN 12d Primary Street: Wilkesboro Blvd Cross Street: HWY 321 Direction: Westbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

DOWNTOWN GREENWAY (GW)

Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

VISITOR CENTER

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-31


Priority Placement Zone: 12 a/b/c/d

ABC COUR T NE

ING R OCK B OUL

E VA R

D

12a

TE

HW

12d

BLOW

S TA

FIELD NOTES:

Y9 0

HAR

PER

AV E

£ ¤ 321

17c S TA

12b

TE H WY

£ ¤

BOU RO O B KES WIL

LEV

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

NE ARD

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.

64

18

(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.

17b

(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

HICK

ORY B OUL

E VA R

D

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

12c

L

K IN

SI

DE

WAYFINDING SYSTEM

CT

Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

LEGEND:

Issue 1

136 Furman Rd.

Boone, NC 28607

Ph: 828.386.1866

PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Date June 2022

GRAPHIC LAYOUTS & LOCATIONS

G-32


Sign 13 a/b/c

*WILL REQUIRE 2 MINOR SIGNS AT THE END OF MULBERRY ST (ON NORWOOD ST)

AND AT LAKEWOOD CIRCLE

SIGN 13a MULBERRY REC CENTER *TH BROYHILL WALKING PARK (GW) GREENWAY (GW)

Primary Street: Mulberry St Cross Street: Morganton Blvd/HWY 64 Direction: Southbound Speed Limit: 25 Sign Type: Minor Letter Size: 4”

FIELD NOTES:

SIGN 13c MULBERRY REC CENTER Primary Street: Morganton Blvd/HWY 64 Cross Street: Mulberry St Direction: Southbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

*TH BROYHILL WALKING PARK (GW)

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.

DOWNTOWN

(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

SIGN 13b-1

SIGN 13b-2

DOWNTOWN

AQUATIC CENTER (GW)(MTB)

HOSPITAL

*TH BROYHILL WALKING PARK (GW)

MULBERRY REC CENTER

GREENWAY (GW)

Primary Street: Morganton Blvd/HWY 64 Cross Street: Mulberry St Direction: Northbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-33


Priority Placement Zone: 13 a/b/c

PA

RK

S

E TR

ET

SW

PE

N

O NT

N

A

S VE

W

13a M

13c

OR

G

T AN

ON

BO

E UL

VA

MU

£ ¤ 64

LB ER

£ ¤

RY

321

ST RE ET SW

ST

AT

E

G HI

HW

AY

RD

SW

FIELD NOTES:

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

18

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

MA

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

SW ET TRE IN S

13b-2

WAYFINDING SYSTEM

13b-1

Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

LEGEND:

Issue 1

136 Furman Rd.

Boone, NC 28607

Ph: 828.386.1866

PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Date June 2022

GRAPHIC LAYOUTS & LOCATIONS

G-34


*WILL REQUIRE 1 MINOR DIRECTIONAL SIGN ON COLLEGE AVE AND 1

SIGN 14a DOWNTOWN

**THE CAMPUS (GW)

*COMMUNITY GARDENS (GW)

Sign 14 a/b/c ON BEALL ST

**WILL REQUIRE 2 MINOR SIGNS AT WILLOW ST & HARPER AVE

Primary Street: Creekway Dr Cross Street: Harper Ave Direction: Southbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

FIELD NOTES:

SIGN 14c

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

Primary Street: Harper Ave Cross Street: Creekway Dr/Harper Ave Direction: Southbound Speed Limit: 35 Sign Type: Major Letter Size: 5”

AQUATIC CENTER (GW)(MTB) SOCCER COMPLEX (GW)(MTB) GREENWAY (GW)

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

SIGN 14b SOCCER COMPLEX (GW)(MTB)

DOWNTOWN

*COMMUNITY GARDENS (GW)

Primary Street: Harper Ave Cross Street: Harper Ave Direction: Northbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-35


14a

NW CLE TO R R E N C E CIR

CR EE KWAY DR IV E NW

Sign 14 a/b/c

HA

14c ST

A

H TE

W

8 Y1

BU

RP

E

V RA

EN

W

FIELD NOTES:

S

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

CO

LU

MB

US

ST

RE

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.

ET

SW

(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.

BRA

(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

DFO RD

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

STR EET SW

AB

WAYFINDING SYSTEM

IN GT

14b

ON RO AD

Project #: Drawn By: Checked By: Scale: Varies

NW

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

LEGEND:

Issue 1

136 Furman Rd.

Boone, NC 28607

Ph: 828.386.1866

PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Date June 2022

GRAPHIC LAYOUTS & LOCATIONS

G-36


*WILL REQUIRE 1 MINOR DIRECTIONAL SIGN ON COLLEGE AVE AND 1

SIGN 15a MULBERRY REC CENTER **TH BROYHILL WALKING PARK (GW) GREENWAY (GW)

Sign 15 a/b/c/d

ON BEALL ST

**WILL REQUIRE 2 MINOR SIGNS AT THE END OF MULBERRY ST (ON NORWOOD ST) Primary Street: Harper Ave Cross Street: Morganton Blvd/HWY 64 Direction: Southbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

SIGN 15c FIELD NOTES: Primary Street: Harper Ave Cross Street: Morganton Blvd/HWY 64 Direction: Northbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

DOWNTOWN

*COMMUNITY GARDENS (GW)

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

MULBERRY REC CENTER

SIGN 15b

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.

MULBERRY REC CENTER DOWNTOWN SOCCER COMPLEX (GW)(MTB)

(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

Primary Street: Morganton Blvd/HWY 64 Cross Street: Harper Ave Direction: Eastbound Speed Limit: 50 Sign Type: Major Letter Size: 5”

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

WAYFINDING SYSTEM

SIGN 15d Primary Street: Morganton Blvd/HWY 64 Cross Street: Harper Ave Direction: Westbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

DOWNTOWN SOCCER COMPLEX (GW)(MTB)

Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

*COMMUNITY GARDENS (GW)

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-37


HAR

PER

15a

AV E

Sign 15 a/b/c/d

RE DB

OL

D

H

AR

R PE

A RO

FIELD NOTES:

D

15d MOR

AR

S TAT E

HWY

UL ON BO T N A G

E VA R

18

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

NL

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.

£ ¤

E

(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

COM

SO UT HW EST BO UL EVA RD

AN

64

PLEX

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

STRE

15b

D SW

W ET S

WAYFINDING SYSTEM

15c

Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

LEGEND:

Issue 1

136 Furman Rd.

Boone, NC 28607

Ph: 828.386.1866

PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Date June 2022

GRAPHIC LAYOUTS & LOCATIONS

G-38


Sign 16 a/b

SIGN 16a CHAMBER OF COMMERCE

CIVIC CENTER

VISITOR CENTER

Primary Street: HWY 321 Cross Street: Civic Center Dr Direction: Southbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

FIELD NOTES:

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.

SIGN 16b

Primary Street: HWY 321 Cross Street: Civic Center Dr Direction: Northbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

DOWNTOWN

(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

THE CAMPUS (GW)

WAYFINDING SYSTEM

VISITOR CENTER

Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-39


HIC

CIV

IC

CE

NT

ER

DR

IVE

Priority Placement Zone: 16 a/b

KO RY BO

16a

UL EV

FIELD NOTES:

AR DD SW

£ ¤ 321

NOTES: HI

(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

CK OR YB

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.

OU LE VA RD

(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.

SE

(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

£ ¤ 321

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

16b

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

LEGEND:

Issue 1

136 Furman Rd.

Boone, NC 28607

Ph: 828.386.1866

PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Date June 2022

GRAPHIC LAYOUTS & LOCATIONS

G-40


Sign 17 a/b/c

*WILL REQUIRE 2 MINOR SIGNS AT THE END OF MULBERRY ST (ON NORWOOD ST)

SIGN 17a GREENWAY (GW) MULBERRY REC CENTER *TH BROYHILL WALKING PARK (GW)

Primary Street: Harper Ave Cross Street: Morganton Blvd/HWY 64 Direction: Eastbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

FIELD NOTES:

SIGN 17c Primary Street: Harper Ave Cross Street: Morganton Blvd/HWY 64 Direction: Westbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

DOWNTOWN

MULBERRY REC CENTER *TH BROYHILL WALKING PARK (GW)

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

SIGN 17b DOWNTOWN THE CAMPUS (GW)

AQUATIC CENTER (GW)(MTB)

Primary Street: Morganton Blvd/HWY 64 Cross Street: Harper Ave Direction: Eastbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-41


Priority Placement Zone: 17 a/b/c

VE NA O T N PEN

HAR

PER

AV E

NW

FIELD NOTES:

SW

17a NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

HAR

PER

17c AV E

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.

NW

(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.

12b

(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

SW

VA R D S W

17b

TO

NB

OU

RY BO ULE

LEV

AR

DS

W

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

H I C KO

AN

ST

RG

IFT

MO

THR

LEGEND:

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

Boone, NC 28607

Ph: 828.386.1866

PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Date June 2022

GRAPHIC LAYOUTS & LOCATIONS

G-42


Sign 18 a/b SIGN 18a LIBRARY (GW) DOWNTOWN THE CAMPUS (GW)

Primary Street: HWY 321 Cross Street: Hospital Ave Direction: Southbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

FIELD NOTES:

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

SIGN 18b Primary Street: HWY 321 Cross Street: Hospital Ave Direction: Northbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

DOWNTOWN

WAYFINDING SYSTEM

LIBRARY (GW)

GREENWAY (GW)

Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-43


Priority Placement Zone: 18 a/b

321 18a ¤ £

BLOW OUL OCK B ING R

FIELD NOTES: LIBRARY

E VA R

E AV L A PIT S HO

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

D (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.

S HO

PIT

A

V LA

EN

(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.

W

(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

£ ¤ 321

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

18b

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

LEGEND:

Issue 1

136 Furman Rd.

Boone, NC 28607

Ph: 828.386.1866

PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Date June 2022

GRAPHIC LAYOUTS & LOCATIONS

G-44


Sign 19 a/b/c SIGN 19a DOWNTOWN AQUATIC CENTER (GW)(MTB) ATHLETIC PARK (GW)

Primary Street: Nuway Circ Cross Street: Powell Rd Direction: Southbound Speed Limit: 35 Sign Type: Major Letter Size: 5”

FIELD NOTES:

SIGN 19c NOTES: Primary Street: Powell Rd Cross Street: Nuway Circ Direction: Westbound Speed Limit: 25 Sign Type: Minor Letter Size: 4”

DOWNTOWN MLK REC CENTER SOCCER COMPLEX (GW)(MTB)

(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

SIGN 19b SOCCER COMPLEX (GW)(MTB)

AQUATIC CENTER (GW)(MTB)

ATHLETIC PARK (GW)

Primary Street: Nuway Circ Cross Street: Powell Rd Direction: Northbound Speed Limit: 35 Sign Type: Major Letter Size: 5”

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-45


Priority Placement Zone: 19 a/b/c

19a

FIELD NOTES:

NOTES:

19c

E

L BE

P

C LA

(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

E

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.

FO

R D VI L L AG E

LE N E

AY C IRC

(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

LL RO

E RO AD 1 523

NE

NUW

AD

CAMELO

19b

WAYFINDING SYSTEM

T COURT

Project #: Drawn By: Checked By: Scale: Varies

Client:

S TAT

2b

CIRC

WE

2a

(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.

PO

LE N E

W

EX

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

LEGEND:

Issue 1

136 Furman Rd.

Boone, NC 28607

Ph: 828.386.1866

PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Date June 2022

GRAPHIC LAYOUTS & LOCATIONS

G-46


Sign 20

FIELD NOTES:

SIGN 20 DOWNTOWN

JE BROYHILL PARK THE CAMPUS (GW)

Primary Street: Hospital Ave Cross Street: Harper Ave Direction: Southbound Speed Limit: 25 Sign Type: Minor Letter Size: 4”

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-47


Priority Placement Zone: 20

W

LA

ND

PL

AC

E

NW

FIELD NOTES:

HO

SP

IT

AL

AV

E

NW

AB ER NATH Y ST RE ET NW

NE

HARPER

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.

AV E

(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.

20

(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.

HA

(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

RP

ER

AV

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

E

WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

LEGEND:

Issue 1

136 Furman Rd.

Boone, NC 28607

Ph: 828.386.1866

PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Date June 2022

GRAPHIC LAYOUTS & LOCATIONS

G-48


Sign 21 a/b *WILL REQUIRE 1 MINOR SIGN ON LOWER CREEK DR AND 1 MINOR SIGN ON POWELL RD

SIGN 21a DOWNTOWN *AQUATIC CENTER (GW)(MTB) THE CAMPUS (GW)

Primary Street: Wilkesboro Blvd Cross Street: Taylorsville Rd Direction: Westbound Speed Limit: 45 Sign Type: Major Letter Size: 5”

FIELD NOTES:

NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.

SIGN 21b Primary Street: Taylorsville Rd Cross Street: Wilkesboro Blvd Direction: Westbound Speed Limit: 35 Sign Type: Major Letter Size: 5”

(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

AQUATIC CENTER (GW)(MTB)

WAYFINDING SYSTEM

GREENWAY (GW)

DOWNTOWN

Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

Issue 1

136 Furman Rd.

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Boone, NC 28607

Date June 2022

Ph: 828.386.1866

GRAPHIC LAYOUTS & LOCATIONS

G-49


Priority Placement Zone: 21 a/b

21a

TA YL OR SV

W

IL

KE

O SB

RO

BO

UL

A EV

RD

FIELD NOTES:

IL

NOTES:

LE RO AD

(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)

TA YL OR SV IL

21b

LE

WAYFINDING SYSTEM

RO AD

Project #: Drawn By: Checked By: Scale: Varies

Client:

CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200

LEGEND:

Issue 1

136 Furman Rd.

Boone, NC 28607

Ph: 828.386.1866

PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES

These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.

Date June 2022

GRAPHIC LAYOUTS & LOCATIONS

G-50





Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.