LENOIR WAYFINDING
a citywide wayfinding system
CONTACT
CONTENTS A1 GENERAL WAYFINDING NOTES B1 TYPOGRAPHY STANDARDS
CITY OF LENOIR PO BOX 958 801 WEST AVENUE NW LENOIR, NC 28645 828.757.2200
LANDSCAPE ARCHITECT / PROJECT MANAGER: DESTINATION BY DESIGN 136 FURMAN RD, SUITE 6 BOONE, NC 28607 828.386.1866
C1-C2
SIGN PLACEMENT GUIDELINES
D1 SIGNAGE SYSTEM OVERVIEW
STRUCTURAL ENGINEER: ARETE ENGINEERS, PLLC 7668 VALLEY BLVD. BLOWING ROCK, NC 28607 828.434.0587
E1-E5
DESIGN INTENT
S1-S5
STRUCTURAL DRAWINGS
G1-G50
LOCATIONS PLAN
NOTES: INTENT AND CONTRACTOR SCOPE
These drawings are intended to provide sufficient information to convey general design intent to the sign fabricator/installer and are not for construction. Additional technical advice and detailing may be required for successful completion of this project and is the sign fabricator/installer’s responsibility. Sign fabricator shall be responsible for all site engineering. This shall include verifying the mounting conditions and providing a detail drawing for each mounting condition. Sign fabricator/installer shall provide shop drawings to the Owners and/ or designer for each sign type showing fabrication, mounting system, and installation details. Include fabrication plans, elevations, and component details. Indicate materials, fittings, finishes, fasteners, anchorages, and accessory items. The fabricator/ installer shall notify Destination by Design (828-386-1866) of any discrepancies in the fabrication documents immediately and shall not proceed or allow sub-fabricators to work in those areas until said discrepancies are resolved. When changes are required, for any reason, notify Destination by Design (828-386-1866) before performing any work. Changes which alter the contract documents must have the approval of Destination by Design before commencement of such work. Changes which modify the contract amount must have the approval of Destination by Design and Owner before commencement of such work.
CODES
Sign fabricator/installer shall follow the MUTCD (Manual on Uniform Traffic Control Devices) guidelines for Lateral Offsets. See section 2A.19 Lateral Offset in the Manual on Uniform Traffic Control Devices, 2009 Edition. Standardization of Sign Location & Mounting Heights: Signs requiring different decisions by the road user shall be spaced sufficiently using the MUTCD Standards as a guideline. Where parking or pedestrian movements occur, the clearance to the bottom of the sign shall be at least 7 ft. clearance above grade. Sign fabricator shall ensure that actual sign locations are verified by municipality representative and the North Carolina Department of Transportation (NCDOT), as required, prior to installation. Sign fabricator/ installer shall be responsible for providing and paying for all permits, work, and materials in accordance with all codes, ordinances and regulations applicable at the project location.
WARRANTY
All materials and workmanship shall be guaranteed by the sign fabricator/ installer for five (5) years from the date of substantial completion.
SAMPLES
Fabricator shall conform to these drawings and specifications and submit to Destination by Design samples for all finishes included in their scope of work before commencement of such work. For the purpose of the Request for Proposal process, proprietary names identifying items of work are used solely to describe the standard of the product or the color of the finish, unless the items of work are explicitly noted as not having an equal. Fabricator shall secure approval of any substitutions from Destination by Design. Any items approved for substitution should be submitted to Destination by Design for final approval.
OTHER
Sign fabricator/installer shall be responsible for contacting North Carolina 811 before start of project. Sign fabricator/installer is responsible for the means, methods and techniques of installation, safety precautions in connection with the work, and for the acts or omissions of the subcontractors. Sign fabricator/installer shall provide adequate erosion control as required during the course of the project. All wood in contact with the ground, slabs on grade, or masonry is to be pressure treated. Sign fabricator/installer shall protect all surfaces not involved in the work from any damage. Sign fabricator/installer shall repair all surfaces damaged during the installation of the sign system. The sign fabricator/installer shall keep the site work area(s) clear of unnecessary debris; and shall keep all work area(s) secured when unattended for the duration of the installation period.
DESIGN OWNERSHIP
All ideas, designs, arrangements and plans indicated or presented by these drawings are owned by and are the property of the Owner, and were created, evolved and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of Destination by Design and the Owner. Any and all inquiries in this regard by outside parties should be referred to Destination by Design. In addition, the fabricator must request and receive written approvals to use images of any completed element described in these documents in print or promotional materials of any kind including video, from both Destination by Design and the Owner in order to proceed with publication. Permission to use images of the work for promotional or editorial purposes requires that the Fabricator be responsible for ensuring that credit indicating Destination by Design as the designer be adjacent to those images. If an article in a publication accompanies the images, Destination by Design must be identified as the designer in that article as well.
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GENERAL WAYFINDING NOTES
A-1
Clearview Highway 2 - W ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz 1234567890 “!@#$%^
USE OF ARROWS: WHEN MULTIPLE DIRECTIONS ARE REQUIRED ON A SIGN, THE FOLLOWING DIRECTIONAL HIERARCHY SHALL TAKE PRECEDENT. SEE EXAMPLE BELOW. REFERENCE MESSAGE SCHEDULE FOR INDIVIDUAL MESSAGES. THIS PLAN UTILIZES THE “TYPE B” ARROW FOUND IN MUTCD SECTION 2D.08 FOR ARROW USE ON GUIDE SIGNS. NOTE: THE “STANDARD HIGHWAY SIGNS AND MARKINGS” BOOK CONTAINS THE DETAILS OF THESE ARROW DESIGNS.
The City of Lenoir, incorporated in 1851, was named in recognition of William Lenoir, a hero of the Revolutionary War and early North Carolina entrepreneur. Lenoir acceptable
Lenoir
NOT acceptable
Straight Arrow
Left Arrow
Right Arrow
Le no ir
NOT acceptable
USE OF PICTOGRAPHS:
1234
acceptable
1234
NOT acceptable
123 4
NOT acceptable
Access to Mountain Bike Trails
LETTER SPACING Inconsistencies in Letter Spacing
Corrected Letter Spacing
Le noir
Lenoir
Access to Greenways
IMP O RTANT: Individ ual sp ac i ng of eac h l etter needs to b e e va lu a ted . See Examp l es to the l eft. Ke rn al l Cop y so that eac h c harac ter is optic al l y ce nte re d b etween the center of eac h of the surround i ng ch ara cters.
SIGN TEXT STANDARDS� COPY H EIG H T: To measure copy height, only m e as u re th e he ig h t of th e capita l l etters to deter mine yo u r o ve ra ll co py h e ig ht (s hown b el ow as “X”). Som e of the o th e r lette rs h ave a n ex tended height beyond the a ve rag e h e ig ht of th e letters.
LINE SPACING: To me asure l ine sp ac ing, al ways measure from the bas e line of the top most text l ine to the b asel i ne of the tex t lin e b el ow ( shown as “X”) .
X GREENWAY
GREENWAY X GREENWAY
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
TYPOGRAPHY STANDARDS
Ph: 828.386.1866
B-1
Date June 2022
NOTES: (1) UNLESS APPROVED BY DESTINATION BY DESIGN (828-386-1866), SIGNS SHOULD BE LOCATED ON THE RIGHT-HAND SIDE OF THE ROADWAY (SEE MUTCD SECTION 2A.16 FOR STANDARDIZATION OF LOCATION). (2) SEE MUTCD SECTION 2A.19 FOR REDUCED LATERAL OFFSET DISTANCES THAT MAY BE USED IN AREAS WHERE LATERAL OFFSETS ARE LIMITED, AND IN BUSINESS, COMMERCIAL, OR RESIDENTIAL AREAS WHERE SIDEWALK WIDTH IS LIMITED OR WHERE EXISTING POLES ARE CLOSE TO THE CURB. (3) SEE MUTCD SECTION 2A.18 FOR MOUNTING HEIGHT. THE MINIMUM HEIGHT, MEASURED VERTICALLY FROM THE BOTTOM OF THE SIGN TO THE ELEVATION OF THE NEAR EDGE OF THE PAVEMENT, OF SIGNS INSTALLED AT THE SIDE OF THE ROAD IN RURAL AREAS SHALL BE 5 FEET (SEE DETAILS 1 & 2/SHEET C-1). THE MINIMUM HEIGHT, MEASURED VERTICALLY FROM THE BOTTOM OF THE SIGN TO THE ELEVATION OF THE NEAR EDGE OF THE TRAVELED WAY, OF SIGNS INSTALLED AT THE SIDE OF THE ROAD IN BUSINESS, COMMERCIAL, OR RESIDENTIAL AREAS WHERE PARKING OR PEDESTRIAN MOVEMENTS ARE LIKELY TO OCCUR, OT WHERE THE VIEW OF THE SIGN MIGHT BE OBSTRUCTED, SHALL BE 7 FEET (SEE DETAIL 3/ SHEET C-1).
5 FT MIN.
12 FT MIN.
2 ROADSIDE SIGN IN A RURAL AREA WITH A SHOULDER
SIGN
PRIORITY PLACEMENT DISTANCE BETWEEN TWO SIGNS
*SPEED DEPENDENT
SIGN
7 FT* MIN.
>50’
2 FT MIN.
200’-250’
100’-400’
1 ROADSIDE SIGN IN A RURAL AREA
6 FT MIN.
5 FT MIN.
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
3 ROADSIDE SIGN IN A BUSINESS, COMMERCIAL, OR RESIDENTIAL AREA
4 SIGN PLACEMENT GUIDELINES
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
*NOT TO SCALE
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
SIGN PLACEMENT GUIDELINES
Date June 2022
Ph: 828.386.1866
C-1
LEGEND: MEASURE
F
C
MINIMUM DISTANCE
OPTIMAL DISTANCE
A
DISTANCE FROM EDGE OF SIGN PANEL TO EDGE OF CURB
1’-0”
2’-0” OR MORE
B
DISTANCE FROM SIGN POST TO NEAREST OBSTRUCTION
3’-0”
4’-0” OR MORE
C
DISTANCE FROM EDGE OF SIGN PANEL TO NEAREST OVERHEAD OBSTRUCTION
1’-0”
4’-0” OR MORE
D
SIGN PLACEMENT IN RELATION TO ADJACENT BUILDING
DO NOT OBSTRUCT ENTRANCE
ALIGN TO BUILDING EDGE
E
DISTANCE FROM FACE OF SIGN TO NEAREST TREE BRANCH
15’-0”
20’-0” OR MORE
F
DISTANCE FROM BACK OF SIGN TO NEAREST TREE BRANCH
3’-0”
8’-0” OR MORE
G
DISTANCE FROM FACE OF SIGN TO NEAREST UTILITY POLE
10’-0”
15’-0” OR MORE
H
DISTANCE FROM BACK OF SIGN TO NEAREST UTILITY POLE
10’-0”
15’-0” OR MORE
B E
H
G
A
FIELD NOTES:
D
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
SIGN PLACEMENT GUIDELINES
Date June 2022
Ph: 828.386.1866
C-2
LOCAL CREATOR ARTWORK TYP.; SEE EXHIBT
LOCAL CREATOR ARTWORK TYP.; SEE EXHIBT
LOCAL CREATOR ARTWORK TYP.; SEE EXHIBT
LOCAL CREATOR ACCENTS EXHIBIT:
LOCAL CREATOR ARTWORK TYP.; SEE EXHIBT
THE LOCAL CREATOR ACCENTS SPACE IS AN AREA ON SIGNAGE PRESERVED FOR LOCAL ARTISTS TO DESIGN AND INSTALL SCULPTURAL ELEMENTS THAT CELEBRATE THE CITY OF LENOIR’S INDUSTRIAL AND ARTISTIC ROOTS.
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
SIGNAGE SYSTEM OVERVIEW
Date June 2022
Ph: 828.386.1866
D-1
5'-6" 5'
6"
DESTINATION PANEL LAYOUT NOTES:
(4) ALL GRAPHICS SHOWN ARE FOR ILLUSTRATIVE PURPOSES ONLY. CONTACT DESTINATION BY DESIGN FOR BASE ADOBE ILLUSTRATOR FILES (828-386-1866). DESTINATION BY DESIGN TO PROVIDE TYPICALS FOR EACH SIZE PANEL. THE CONTRACTOR SHALL PROVIDE FINAL FOR PRINT PROOF AT EACH SIGN LOCATION.
3" 5"
4"
1"
1"
(3) ALL PANELS OF 1/4” ALUMINUM.
3" MIN.
3"
3"
(2) PANEL LAYOUTS FOR ALL SIGN LOCATIONS SHALL BE INCLUDED IN SHOP DRAWINGS FOR REVIEW BY DESTINATION BY DESIGN (828-386-1866).
8"
2" 5"
5"
(1) MESSAGES SHOWN ARE FOR ILLUSTRATIVE PURPOSES ONLY. REFER TO SECTION H FOR SIGN MESSAGES.
3" 2" 3"
3" MIN.
3"
10"
1'-9" 6'-6"
4"
4"
1'-6"
10"
8"
2"
3" 2" 3"
6'
1'-4"
1'-9"
6"
MINOR WAYFINDING DESTINATION PANEL
MAJOR WAYFINDING DESTINATION PANEL 4'-6"
6'
MINOR WAYFINDING BACK PANEL COLOR SAMPLE
NAME NAVY
PANTONE ID 3035 C
7"
6'-6"
6"
4'
MAJOR WAYFINDING BACK PANEL
WAYFINDING SYSTEM
DETAILS For Paint color match to Pantone. Surface applied, exterior paint and protective top coat: MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish. For vinyl print with approved 3M MCS Printing Methods.
DARK TEAL
2221 C
For Paint color match to Pantone. Surface applied, exterior paint and protective top coat: MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish. For vinyl print with approved 3M MCS Printing Methods.
MEDIUM TEAL
2232 C
For Paint color match to Pantone. Surface applied, exterior paint and protective top coat: MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish. For vinyl print with approved 3M MCS Printing Methods.
Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
DESTINATION PANELS
Date June 2022
Ph: 828.386.1866
E-1
FABRICATION COMPONENTS:
create with us
1
POST: TWO (2) 12” X 4” X 1/4” ALUMINUM POSTS TO FORM “L” SHAPE
2
DESTINATION PANEL: 1/4 INCH ALUMINUM SHEET WITH 3MTM 3930 HIGH INTENSITY PRISMATIC SHEETING APPLIED ON RAW SURFACE. EDGE AND BACK TO HAVE MATTHEWS PAINT.
3
BACK DESTINATION PANEL: 1/4 INCH ALUMINUM WITH 3M SCOTCHAL GRAPHIC FILM IJ3650 APPLIED ON RAW SURFACE. EDGE OF SHEET TO HAVE MATTHEWS PAINT.
4
PANEL SUPPORT: 4” X 4” X 1/4” STEEL FRAME (4’W X 5.5’H 3 SIDED RECTANGLE) WELDED TO SIDE OF MAIN SUPPORT WITH HOLES FOR PANEL ATTACHMENT. SEE STRUCTURAL.
5
LETTERING: 1/4 INCH ALUMINUM LETTERING (6” TEXT HEIGHT) AFFIXED ON THE SIDE OF THE MAIN SUPPORT - CENTERED WITH POST AND PANEL HEIGHT. FONT: DDC HARDWARE.
6
BASE: CONNECTION TO FOUNDATION WITH NCDOT BREAKAWAY SYSTEM (TRANSPO OR EQUAL) SEE STRUCTURAL DRAWINGS .
7
LOCAL CREATOR ACCENTS SPACE: METAL DETAILS ON TOP AND BOTTOM OF DESTINATION PANEL. ATTACHED TO SIDE OF MAIN SUPPORT AND TOP/BOTTOM OF PANEL SUPPORT. TOP DETAIL NOT TO EXCEED 5’ W X 1’6” H. BOTTOM DETAIL NOT TO EXCEED 4’ W X 1’H.
FINISHES PALETTE: P1
“BURNT RUST” POWDER COAT (PTB 6884/TEXTURE): POLYURETHANE TEXTURE POWDER COAT WITH FLAT FINISH BY PRISMATIC POWDERS.
P2
“STAINLESS”: BRUSHED ALUMINUM WITH CLEAR COAT PROTECTION.
P3
BLUE MATTHEW’S PAINT: COLOR MATCH TO PANTONE 3035 C. SUBSTRATE SHOULD BE PRIMED PRIOR TO TOPCOAT. SATIN FINISH.
VINYL SHEETING: V1
REFLECTIVE 3MTM 3930 HIGH INTENSITY PRISMATIC SHEETING: TO BE PRINTED WITH APPROVED 3M MCS PRINTING METHODS.
V2 3M SCOTCHCAL GRAPHIC FILM IJ3650: TO BE PRINTED WITH APPROVED 3M MCS PRINTING METHODS.
NOTES: ALL ATTACHMENT HARDWARE MADE INCONSPICUOUS, PAINTED TO MATCH ATTACHMENT SURFACE.
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
MAJOR WAYFINDING (LOCAL CREATOR)
E-2
FABRICATION COMPONENTS:
create with us
1
POST: TWO (2) 12” X 4” X 1/4” ALUMINUM POSTS TO FORM “L” SHAPE
2
DESTINATION PANEL: 1/4 INCH ALUMINUM SHEET WITH 3MTM 3930 HIGH INTENSITY PRISMATIC SHEETING APPLIED ON RAW SURFACE. EDGE AND BACK TO HAVE MATTHEWS PAINT.
3
BACK DESTINATION PANEL: 1/4 INCH ALUMINUM WITH 3M SCOTCHAL GRAPHIC FILM IJ3650 APPLIED ON RAW SURFACE. EDGE OF SHEET TO HAVE MATTHEWS PAINT.
4
PANEL SUPPORT: 4” X 4” X 1/4” STEEL FRAME (4’W X 5.5’H 3 SIDED RECTANGLE) WELDED TO SIDE OF MAIN SUPPORT WITH HOLES FOR PANEL ATTACHMENT. SEE STRUCTURAL.
5
LETTERING: 1/4 INCH ALUMINUM LETTERING (6” TEXT HEIGHT) AFFIXED ON THE SIDE OF THE MAIN SUPPORT - CENTERED WITH POST AND PANEL HEIGHT. FONT: DDC HARDWARE.
6
BASE: CONNECTION TO FOUNDATION WITH NCDOT BREAKAWAY SYSTEM (TRANSPO OR EQUAL) SEE STRUCTURAL DRAWINGS .
FINISHES PALETTE: P1
“BURNT RUST” POWDER COAT (PTB 6884/TEXTURE): POLYURETHANE TEXTURE POWDER COAT WITH FLAT FINISH BY PRISMATIC POWDERS.
P2
“STAINLESS”: BRUSHED ALUMINUM WITH CLEAR COAT PROTECTION.
P3
BLUE MATTHEW’S PAINT: COLOR MATCH TO PANTONE 3035 C. SUBSTRATE SHOULD BE PRIMED PRIOR TO TOPCOAT. SATIN FINISH.
VINYL SHEETING: V1
REFLECTIVE 3MTM 3930 HIGH INTENSITY PRISMATIC SHEETING: TO BE PRINTED WITH APPROVED 3M MCS PRINTING METHODS.
V2
3M SCOTCHCAL GRAPHIC FILM IJ3650: TO BE PRINTED WITH APPROVED 3M MCS PRINTING METHODS.
NOTES: ALL ATTACHMENT HARDWARE MADE INCONSPICUOUS, PAINTED TO MATCH ATTACHMENT SURFACE.
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
MAJOR WAYFINDING (STANDARD)
E-3
FABRICATION COMPONENTS:
create with us
1
POST: TWO (2) 12” X 4” X 1/4” ALUMINUM POSTS TO FORM “L” SHAPE
2
DESTINATION PANEL: 1/4 INCH ALUMINUM SHEET WITH 3MTM 3930 HIGH INTENSITY PRISMATIC SHEETING APPLIED ON RAW SURFACE. EDGE AND BACK TO HAVE MATTHEWS PAINT.
3
BACK DESTINATION PANEL: 1/4 INCH ALUMINUM WITH 3M SCOTCHAL GRAPHIC FILM IJ3650 APPLIED ON RAW SURFACE. EDGE OF SHEET TO HAVE MATTHEWS PAINT.
4
PANEL SUPPORT: 4” X 4” X 1/4” STEEL FRAME (4’W X 5.5’H 3 SIDED RECTANGLE) WELDED TO SIDE OF MAIN SUPPORT WITH HOLES FOR PANEL ATTACHMENT. SEE STRUCTURAL.
5
LETTERING: 1/4 INCH ALUMINUM LETTERING (6” TEXT HEIGHT) AFFIXED ON THE SIDE OF THE MAIN SUPPORT - CENTERED WITH POST AND PANEL HEIGHT. FONT: DDC HARDWARE.
6
BASE: CONNECTION TO FOUNDATION WITH NCDOT BREAKAWAY SYSTEM (TRANSPO OR EQUAL) SEE STRUCTURAL DRAWINGS .
7
LOCAL CREATOR ACCENTS SPACE: METAL DETAILS ON TOP AND BOTTOM OF DESTINATION PANEL. ATTACHED TO SIDE OF MAIN SUPPORT AND TOP/BOTTOM OF PANEL SUPPORT. TOP DETAIL NOT TO EXCEED 5’ W X 1’6” H. BOTTOM DETAIL NOT TO EXCEED 4’ W X 1’H.
FINISHES PALETTE: P1
“BURNT RUST” POWDER COAT (PTB 6884/TEXTURE): POLYURETHANE TEXTURE POWDER COAT WITH FLAT FINISH BY PRISMATIC POWDERS.
P2
“STAINLESS”: BRUSHED ALUMINUM WITH CLEAR COAT PROTECTION.
P3
BLUE MATTHEW’S PAINT: COLOR MATCH TO PANTONE 3035 C. SUBSTRATE SHOULD BE PRIMED PRIOR TO TOPCOAT. SATIN FINISH.
VINYL SHEETING: V1
REFLECTIVE 3MTM 3930 HIGH INTENSITY PRISMATIC SHEETING: TO BE PRINTED WITH APPROVED 3M MCS PRINTING METHODS.
V2 3M SCOTCHCAL GRAPHIC FILM IJ3650: TO BE PRINTED WITH APPROVED 3M MCS PRINTING METHODS.
NOTES: ALL ATTACHMENT HARDWARE MADE INCONSPICUOUS, PAINTED TO MATCH ATTACHMENT SURFACE.
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
MINOR WAYFINDING (LOCAL CREATOR)
E-4
FABRICATION COMPONENTS:
create with us
1
POST: TWO (2) 12” X 4” X 1/4” ALUMINUM POSTS TO FORM “L” SHAPE
2
DESTINATION PANEL: 1/4 INCH ALUMINUM SHEET WITH 3MTM 3930 HIGH INTENSITY PRISMATIC SHEETING APPLIED ON RAW SURFACE. EDGE AND BACK TO HAVE MATTHEWS PAINT.
3
BACK DESTINATION PANEL: 1/4 INCH ALUMINUM WITH 3M SCOTCHAL GRAPHIC FILM IJ3650 APPLIED ON RAW SURFACE. EDGE OF SHEET TO HAVE MATTHEWS PAINT.
4
PANEL SUPPORT: 4” X 4” X 1/4” STEEL FRAME (4’W X 5.5’H 3 SIDED RECTANGLE) WELDED TO SIDE OF MAIN SUPPORT WITH HOLES FOR PANEL ATTACHMENT. SEE STRUCTURAL.
5
LETTERING: 1/4 INCH ALUMINUM LETTERING (6” TEXT HEIGHT) AFFIXED ON THE SIDE OF THE MAIN SUPPORT - CENTERED WITH POST AND PANEL HEIGHT. FONT: DDC HARDWARE.
6
BASE: CONNECTION TO FOUNDATION WITH NCDOT BREAKAWAY SYSTEM (TRANSPO OR EQUAL) SEE STRUCTURAL DRAWINGS .
FINISHES PALETTE: P1
“BURNT RUST” POWDER COAT (PTB 6884/TEXTURE): POLYURETHANE TEXTURE POWDER COAT WITH FLAT FINISH BY PRISMATIC POWDERS.
P2
“STAINLESS”: BRUSHED ALUMINUM WITH CLEAR COAT PROTECTION.
P3
BLUE MATTHEW’S PAINT: COLOR MATCH TO PANTONE 3035 C. SUBSTRATE SHOULD BE PRIMED PRIOR TO TOPCOAT. SATIN FINISH.
VINYL SHEETING: V1
REFLECTIVE 3MTM 3930 HIGH INTENSITY PRISMATIC SHEETING: TO BE PRINTED WITH APPROVED 3M MCS PRINTING METHODS.
V2
3M SCOTCHCAL GRAPHIC FILM IJ3650: TO BE PRINTED WITH APPROVED 3M MCS PRINTING METHODS.
NOTES: ALL ATTACHMENT HARDWARE MADE INCONSPICUOUS, PAINTED TO MATCH ATTACHMENT SURFACE.
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
MINOR WAYFINDING (STANDARD)
E-5
DESIGN CRITERIA
SOIL EXCAVATION NOTES
SUBMITTALS
1.
2018 NORTH CAROLINA STATE BUILDING CODE:
1.
EXCAVATION OF THE FOOTINGS ARE TO THE DEPTHS REQUIRED AND INDICATED ON PLANS.
THE FOLLOWING COMPONENTS SHALL BE SUBMITTED TO THE
2.
ASCE 7-10
ANY OVER-EXCAVATION OF UNSUITABLE MATERIALS MAY BE NECESSARY BELOW FOOTING
STRUCTURAL ENGINEER OF RECORD FOR REVIEW AND APPROVAL:
3.
DESIGN LOADS
DEPTH. BACKFILL USING No. 57 STONE IN UNIFORM LIFTS COMPACTED TO 95% OF THE DRY
1.
STRUCTURAL STEEL SHOP FRAWING.
O
DEAD LOAD = SELF WEIGHTS
DENSITY TO RE-ESTABLISH FOOTING SUB-GRADE.
2.
NCDOT APPROVED BREAK AWAY ANCHORS.
O
GROUND SNOW LOAD = 30 PSF
USE OF A SMOOTH EDGE BUCKET IS RECOMMENDED TO EXCAVATE FOR FOOTINGS. TOOTHED
3.
CONCRETE MIX DESIGNS
O
ULTIMATE WIND VELOCITY = 115 MPH
BUCKETS MAY ALLOW BEARING SOILS TO PERFORM INEFFECTIVELY AND ALLOW WATER TO
O
BASE WIND VELOCITY = 90 MPH
SATURATE THE FOUNDATION SUB-GRADE.
O
EXPOSURE CATEGORY = C
3.
SOILS SHALL BE DETERMINED TO HAVE 2,000-PSF NET ALLOWABLE BEARING CAPACITY.
O
ASSUMED GROUND BEARING CAPACITY 2-FT BELOW GRADE: 2,000 PSF
4.
FOOTINGS ARE TO BE PLACED WITH A MINIMUM DEPTH FROM FINISHED GRADE TO BEARING
O
ALL BOTTOM OF FOOTINGS SHALL BE CAST A MINIMUM OF 2-FEET BELOW ORIGINAL 5.
Blowing Rock, NC 28605
THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING AND PROTECTING FOUNDATION
OVER-SATURATION. CARE IS TO BE TAKEN TO REMOVE AND REPLACE BEARING SOILS WITH UNIFORM LIFTS OF No. 57 STONE AS NEEDED, COMPACTED TO 95% OF THE DRY DENSITY. 6.
ONCE THE FOOTINGS ARE ABLE TO HANDLE LATERAL LOADING, BACKFILL WITH ENGINEERED
2.
THE CONTRACTOR SHALL COORDINATE HIS WORK ACTIVITIES WITH THE OWNER.
STONE OR No. 57 STONE IN UNIFORM LIFTS. EXTERIOR OF THE FOOTING MAY BE BACKFILLED
3.
CONTRACTOR SHALL MAKE A CAREFUL INSPECTION OF THE SITE TO FAMILIARIZE HIM/HERSELF WITH THE
WITH UNIFORM LIFTS OF SUITABLE SOILS COMPACTED TO 95% OF THE DRY DENSITY BEYOND
ACTUAL CONDITIONS OF THE SITE.
THE PLACEMENT OF THE FOOTING DRAIN. 7.
AND REPORT ANY INACCURACIES TO THE ENGINEER.
DRAWINGS
ROD
PLACEMENT OF THE FLOOR INSULATION AND ANY CONCRETE SLAB-ON-GRADE. AREAS OF EXCAVATION MAY BE NECESSARY TO REMOVE UNSUITABLE MATERIALS PRIOR TO
11.
THE DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT
2.
THE STRUCTURE DURING CONSTRUCTION. 12.
CONCRETE CONSTRUCTION SHALL COMPLY WITH ACI 301 "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR
(LATEST EDITION), AND ACI 302"GUIDE FOR CONCRETE FLOOR AND SLAB CONSTRUCTION" (LATEST EDITION).
BUILDING ANCHOR BOLTS TO BE ASTM F1554, GR. 36, UNLESS NOTED OTHERWISE.
5.
HEADED STUDS TO BE ASTM A108, GR. 1010 THROUGH 1020 AND SHALL MEET THE
STEEL" AWS D1.1). 6.
GROUT FOR COLUMN BASE PLATES AND PRESET BEARING PLATED SHALL BE NON-SHRINK, NON-METALLIC GROUT WITH MINIMUM F'C = 5,000 PSI.
7.
BEAM CONNECTIONS SHALL BE AS SHOWN OR NOTED ON DRAWINGS.ECCENTRIC OR ONE-
DRAWINGS. CONNECTIONS AND DETAILS ARE SUBJECT TO ENGINEER'S APPROVAL.
MINIMUM CEMENT CONTENT = 500 LBS PER CUBIC YARD.
8.
ALL STRUCTURAL STEEL MEMBERS AND SHAPES EXPOSED TO THE EXTERIOR SHALL BE HOTDIPPED GALVANIZED AS FOLLOWS:
CONCRETE SHALL BE NORMAL WEIGHT CONCRETE AND SHALL DEVELOP A MINIMUM COMPRESSIVE
A. ALL NUTS, BOLTS AND WASHERS:
STRENGTH OF 3,000 PSI AT 28 DAYS. 6.
MAXIMUM SLUMP = 4" PLUS OR MINUS 1".
7.
THE MAX AGGREGATE SIZE SHALL BE 3/4".
8.
CONCRETE AGGREGATES SHALL COMPLY WITH ASTM C33 AND SHALL BE FREE OF CLAY, FOAM, LUMPS OR
ASTM A153, CLASS C OR D (DEPENDING ON SIZE)
B. ALL OTHER STEEL ITEMS: 9.
ANCHOR BOLTS, BASE PLATES AND BEARING PLATES SHALL BE LOCATED AND BUILT INTO
SET IN FULL BEDS OF NON-SHRINK GROUT. ALL POCKETS FOR COLUMNS AND BEAMS MUST
REINFORCING BARS SHALL BE DEFORMED AND CONFORMING TO ASTM A615, GRADE 60.
BE COMPLETELY FILLED WITH SOLID MASONRY AND/OR GROUT.
10.
WELDED WIRE FABRIC SHALL CONFORM TO ASTM A1064 AND BE SUPPLIED IN SHEETS, NOT ROLLS, U.N.O.
11.
CONCRETE SHALL BE AIR ENTRAINED WITH 6% AVERAGE AIR CONTENT WITH A 1.5% TOLERANCE. AIR
10.
ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS USING MATCHING WELD METAL IN CONFORMANCE WITH LATEST EDITION OF A.W.S. D1.1.
ENTRAINMENT SHALL COMPLY WITH ASTM C260.
11.
ALL STRUCTURAL STEEL SHALL BE FABRICATED IN SHOP.
12.
REINFORCEMENT LAP SPLICES SHALL BE 44 TIMES THE BAR DIAMETER UNLESS OTHERWISE NOTED.
12.
DO NOT MODIFY STRUCTURAL STEEL IN FIELD. RETURN ANY STEEL NOT PROPERLY DETAILED
13.
REINFORCEMENT COVER SHALL BE 3" WHEN POURED ADJACENT TO GROUND SURFACE AND 1.5" ELSEWHERE,
CONCRETE SHALL BE CONSOLIDATED USING CONCRETE VIBRATOR IN ACCORDANCE WITH 309R-05.
AB AFG
ANCHOR BOLT
LLH
LONG LEG HORIZONTAL
ABOVE FINISH GRADE
LLV
LONG LEG VERTICAL
ALUM
ALUMINUM
MAX
MAXIMUM
ARCH
ARCHITECTURAL, ARCHITECTURE
MIN
MINIMUM
B/O
BY OTHERS
CL
KO
KNOCK-OUT
CENTER LINE
NTS
NOT TO SCALE
CLR
CLEAR
O/C
ON CENTER
CONTROL JOINT
OD
OUTSIDE DIAMETER
CONNECTING WORK, PRE-SET BY TEMPLATES OR SIMILAR METHODS. ALL PLATES SHALL BE
9.
U.N.O.
ABBREVIATIONS
ASTM A123
OTHER DELETERIOUS SUBSTANCES.
14.
SCALE: 3" = 1'-0"
REQUIREMENTS OF THE AMERICAN WELDING SOCIETY, "STRUCTURAL WELDING CODE -
DETAILING OF CONCRETE REINFORCEMENT" (LATEST EDITION). MIX DESIGN SHALL BE IN ACCORDANCE WITH ACI 318 (CURRENT EDITION).
TYPICAL SIGN TO FRAME CONNECTION
SIZE BOLT USED, UNLESS NOTED OTHERWISE.
SIDED CONNECTIONS WILL NOT BE PERMITTED UNLESS APPROVED AND INDICATED ON
4.
1 S1
BOLTED CONNECTIONS TO USE A 325X BOLTS, UNLESS NOTED OTHERWISE,BOLT HOLES IN
REINFORCING STEEL SHALL BE FABRICATED AND PLACED IN COMPLIANCE WITH ACI 315 "DETAILS AND
3.
5.
ASTM A53, GR. B. (FY = 35 KSI)
SHOP AND FIELD WELDS TO USE E70XX ELECTRODES. MINIMUM FILLET WELD SIZE TO BE
4.
BUILDINGS" (LATEST EDITION), ACI 318 "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE"
2.
ASTM A500. GR. B. (FY = 42 KSI)
E. PIPE
STEEL EXCEPT IN BASE PLATES SHALL BE 1/16 INCH LARGER IN DIAMETER THAN THE NORMAL
CONCRETE NOTES 1.
D.HSS-ROUND
REQUIRED. WELD SIZE SHALL BE AISC MINIMUM UNLESS A LARGER SIZE IS NOTED. 3.
AND DETAILS WITHIN STRUCTURAL DOCUMENTS. ALL SECTIONS AND DETAILS ARE NOT COMPLETE
WITH VIEWS OF OTHER SECTIONS, PLANS AND DETAILS MAY BE REQUIRED TO COMPLETE ASSEMBLY.
ASTM A500, GR. B. (FY = 46 KSI)
(AWS D1.1). WELD LENGTH SCALED FOR ON PLANS ARE THE NET EFFECTIVE LENGTH
IS RESPONSIBLE FOR COORDINATION OF ALL DETAILS WITH OTHER TRADES, DISCIPLINES AND ALL SECTIONS
REPRESENTATIONS OF CONDITIONS BUT ARE SPECIFIC TO ITEMS INDICATED IN DETAILS. COORDINATION
(FY = 36 KSI)
C. HSS-RECTANGULAR
WITH THE AMERICAN WELDING SOCIETY'SCODE FOR WELDING IN BUILDING CONSTRUCTION
SECTIONS AND DETAILS SHOWN AT LOCATIONS INDICATED ON PLAN ARE TYPICAL FOR OTHER SIMILAR CONDITIONS OF BUILDING EVEN IF NO SECTION CUT IS INDICATED AT A SIMILAR CONDITION. CONTRACTOR
(FY = 50 KSI)
ASTM A36
3/16", UNLESS NOTED OTHERWISE. ALL WELDS SHALL BE PREQUALIFIED IN CONFORMITY
APPLY TERMITE TREATMENT TO GROUND SURFACES WITHIN THE DEFINED SCOPE OF WORK AS REQUIRED BY CODE AND LOCAL BUILDING INSPECTOR.
13.
ASTM A992
B. ANGLE, CHANNEL, & PLATE
OR FABRICATED TO FABRICATOR. 13.
ALL STRUCTURAL STEEL SHALL RECEIVE ONE SHOP COAT OF FABRICATORS STANDARD SHOP PRIMER.
CJ
CONCRETE MASONRY UNIT
PSF
POUNDS PER SQUARE FOOT
CONN
CMU
CONNECTION, CONNECT
PSI
POUNDS PER SQUARE INCH
CONT
CONTINUOUS
DWG
DRAWING, DRAWINGS
SOG
SLAB-ON-GRADE
ENG
ENGINEER, ENGINEERING
STD
STANDARD
EQ
EQUAL
SST
SIMPSON STRONG TIE
FC
REINF
REINFORCEMENT, REINFORCING
COMPRESSIVE STRENGTH
TBD
TO BE DECIDED
FDN
FOUNDATION
T/O
TOP OF
TYP
TYPICAL
FY
YIELD STRESS
GC
GENERAL CONTRACTOR
UNO
UNLESS NOTED OTHERWISE
GN
GENERAL NOTES
WWF
WELDED WIRE FABRIC
GR
GRADE
Ø
DIAMETER
SHEET INDEX S1
COVER SHEET AND GENERAL NOTES
S2
STANDARD SIGN POST AND FRAME ELEVATIONS
S3
LOCAL CREATOR SIGN POST AND FRAME DETAILS
S4
SIGN POST AND FRAME DETAILS
S5
SIGN POST FOUNDATION DETAILS
SHEET NUMBER
S1
AS NOTED
WITH THE WORK.
A. W-SECTION
SCALE
DETAILS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER, AND RESOLVED BEFORE PROCEEDING
2963
OMISSIONS OR CONFLICTS BETWEEN VARIOUS ELEMENTS OF THE DRAWINGS, SPECIFICATIONS, NOTES AND
TYP.
WALL, TYP.
FOLLOWING ASTM STANDARDS:
NEW AND EXISTING STRUCTURES AND FOUNDATIONS UNTIL CONSTRUCTION IS COMPLETE. 10.
ALL STEEL SECTIONS SHALL BE PRODUCED DOMESTICALLY AND CONFORM TO THE
PROJECT No.
1.
GENERAL CONTRACTOR SHALL DESIGN AND INSTALL ALL TEMPORARY SHORING REQUIRED TO STABILIZE
LENOIR, NC
9.
SS BARRIER BOLT, 1/4" HSS
BPM
FOUNDATION LAYOUT AND FABRICATION OF ANY STRUCTURAL MEMBERS.
APPROVED BY
CONTRACTOR SHALL COORDINATE ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO
MULTIPLE LOCATIONS
8.
STRUCTURAL STEEL
BPM
1-1/2" LONG 1/4"-20
MASONRY PRIOR TO PLACEMENT.
REVIEWED BY
TAMPER RESISTANT
ELEVATION.
DEPRESSIONS, BOLTS, SLEEVES, ANCHORS, INSERTS, OPENINGS, ETC. TO BE SET OR CAST IN CONCRETE OR
AT
LIFTS OF No. 57 STONE COMPACTED TO 95% OF THE DRY DENSITY UP TO SUB-GRADE
CONTRACTOR SHALL COORDINATE AND VERIFY THE SIZE, LOCATION, TYPE, AND DIRECTION OF ALL PADS,
GT
PLACING THE VAPOR BARRIER: EXCAVATE AND REPLACE UNSUITABLE SOILS WITH UNIFORM
GOVERN.
DRAWN BY
9.
APPLICABLE ASTM STANDARDS, IN CASES OF CONFLICT, THE MOST STRINGENT REQUIREMENT SHALL
DESTINATION BY DESIGN
7.
A 6 MIL VAPOR BARRIER IS TO BE PLACED OVER THE ENTIRETY OF THE SUB-BASE, PRIOR TO
DATE
THE AISC CODE, THE ACI BUILDING CODE (ACI 318), THE AMERICAN WELDING SOCIETY CODE AND ALL
8.
REVISIONS
ALL WORK SHALL CONFORM TO THE CURRENT EDITIONS OF THE NORTH CAROLINA STATE BUILDING CODE,
THREADED
STONE IS TO BE PLACED PRIOR TO ANY CONCRETE SLAB-ON-GRADE.
6.13.2022 No.
CONTRACTOR SHALL COORDINATE THESE STRUCTURAL DRAWINGS WITH DRAWINGS OF OTHER DISCIPLINES.
6.
TYP., SEE DESIGN INTENT
A UNIFORM 8-IN. LIFT OF SUB-BASE, No. 57 STONE OR AN ENGINEERED APPROVED ALTERNATE
DATE
5.
WITH GRAPHIC FILM, 1/4"-20 SS
FOR
CONTRACTOR SHALL CHECK AND VERIFY GIVEN DIMENSIONS, TAKE ADDITIONAL DIMENSIONS AS REQUIRED
1/4" ALUMINUM SHEET
STRUCTURAL DRAWINGS
4.
FIRM LICENSE No. P-1357
BEARING SOILS FROM DISTURBANCE AND DAMAGE DURING CONSTRUCTION AND FROM
CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING EXISTING UNDERGROUND UTILITIES IN THE AREA OF CONSTRUCTION.
P.O. Box 745
HSS
OF NOT LESS THAN 24-INCHES.
GENERAL NOTES 1.
ARETÉ ENGINEERS, PLLC 7668 Valley Blvd.
4"
LENOIR WAYFINDING SIGNAGE COVER SHEET AND GENERAL NOTES
GROUND LINE. NO FOOTINGS SHALL BE CAST ON FILL MATERIAL.
2.
1/4" CAP PLATE
5'-10" 4'-6"
5'-10" 1'-4"
1'-0"
1'-4"
4'-6"
1'-0" ARETÉ ENGINEERS, PLLC 7668 Valley Blvd.
1'-6"
1'-6"
1'-6"
4"
P.O. Box 745 Blowing Rock, NC 28605
1
DATE 3 S4
REAR SIDE
LEFT SIDE
FRONT SIDE
RIGHT SIDE
2 S2
MAJOR WAYFINDING (STANDARD) - SIGN POST AND FRAME SCALE: 1/4" = 1'-0"
S2
AS NOTED
2963
SCALE
PROJECT No.
APPROVED BY
BPM
REVISIONS SHEET NUMBER
LENOIR, NC
8'-0"
S4
8'-0"
2
MULTIPLE LOCATIONS
SCALE: 1/4" = 1'-0"
14'-11 1/8 "
15'-6"
MAJOR WAYFINDING (STANDARD) - SIGN POST AND FRAME
7'-5"
1 S2
BPM
1'-6"
1'-6" 1 S4
REVIEWED BY
RIGHT SIDE
6'-0"
FRONT SIDE
6'-0"
1'-6" LEFT SIDE
6'-0"
REAR SIDE
AT
4"
S4
GT
1'-0"
DRAWN BY
4'-0"
DESTINATION BY DESIGN
1'-4"
6.13.2022 No.
1'-0"
DATE
1'-4"
FRAME ELEVATIONS
4'-0"
3
5'-4"
STRUCTURAL DRAWINGS
5'-4"
LENOIR WAYFINDING SIGNAGE
8'-0"
8'-0"
7'-5"
1/4" CAP PLATE
STANDARD SIGN POST AND
2 S4
FOR
16'-0"
15'-5 1/8 "
S4
6'-6"
6'-6"
6'-6"
FIRM LICENSE No. P-1357
1/4" CAP PLATE
5'-10" 4'-6"
5'-10" 1'-4"
1'-0"
1'-4"
4'-6"
1'-0" ARETÉ ENGINEERS, PLLC 7668 Valley Blvd.
LOCAL CREATOR
1'-6"
1'-6"
4"
P.O. Box 745
CONNECTION POINT,
Blowing Rock, NC 28605
SEE DETAIL 6/S2
1
8'-0"
S4
8'-0"
2
3 S4
REAR SIDE
LEFT SIDE
FRONT SIDE
RIGHT SIDE
DATE
2 S3
MAJOR WAYFINDING (LOCAL CREATOR) - SIGN POST AND FRAME SCALE: 1/4" = 1'-0"
S3
AS NOTED
2963
SCALE
PROJECT No.
APPROVED BY
BPM
REVISIONS SHEET NUMBER
LENOIR, NC
SCALE: 1/4" = 1'-0"
14'-11 1/8 "
15'-6"
MAJOR WAYFINDING (LOCAL CREATOR) - SIGN POST AND FRAME
7'-5"
1 S3
BPM
1'-6" 1 S4
MULTIPLE LOCATIONS
RIGHT SIDE
6'-0"
FRONT SIDE
6'-0"
1'-6" LEFT SIDE
6'-0"
REAR SIDE
REVIEWED BY
4"
S4
AT
1'-0"
GT
4'-0"
DRAWN BY
1'-4"
DESTINATION BY DESIGN
1'-0"
6.13.2022 No.
1'-4"
DATE
4'-0"
3
5'-4"
FOR
SEE DETAIL 6/S2 5'-4"
POST AND FRAME ELEVATIONS
8'-0"
8'-0"
7'-5"
CONNECTION POINT,
STRUCTURAL DRAWINGS
LOCAL CREATOR 1/4" CAP PLATE
LOCAL CREATOR STANDARD SIGN
2 S4
LENOIR WAYFINDING SIGNAGE
16'-0"
15'-5 1/8 "
S4
6'-6"
6'-6"
6'-6"
FIRM LICENSE No. P-1357
4 S4
VARIES (SEE ELEVATIONS) 6"
EQUAL
EQAL
EQUAL
6"
1/4" CAP ARETÉ ENGINEERS, PLLC 7668 Valley Blvd.
PLATE GRIND FLUSH
6"
4" HSS12X4X1/4, POST
TOP OF
P.O. Box 745
POST
6-12 3"
Blowing Rock, NC 28605 FIRM LICENSE No. P-1357
GRIND
EQUAL
FLUSH
1'-0"
POST
HSS4X4X1/4 1'-6"
HSS12X4X1/4,
SIGN POST
HSS4X4X1/4, SEE SIGN FRAME DETAIL
EQUAL 6"
POST
18"
1" THICK STEEL
4
TYP.
S4 2 S4
TYPICAL SIGN FRAME SCALE:
5
1" = 1'-0"
S4
SIGN POST L.C CONNX. SCALE:
1 1/2" = 1'-0"
HSS4X4X1/4 SIGN FRAME (4) 1 1/8"Ø 1/4
BOLT HOLES
4"
1 1/2 "
PLATE
(4) 1/2-13 WELD NUTS 3"
EQUAL
EQUAL
EQUAL
3"
EVENLY SPACED AS SHOWN PROVIDE
4'-0" OR 4'-6"
AT WELD NUT 3 S4
TYPICAL SIGN POST BASE PLATE SCALE:
1 1/2" = 1'-0"
4 S4
SIGN FRAME LOCAL CREATOR (L.C) CONNECTIONS SCALE:
1 1/2" = 1'-0"
LOCATIONS
S4
AS NOTED
2963
SCALE
PROJECT No.
BPM
BPM
SHEET NUMBER
5/8"Ø HOLES IN HSS
LENOIR, NC
HSS12X4X1/4 SIGN
APPROVED BY
1'-0"
TYP.
1 1/2 "
BUILT-UP (2)
MULTIPLE LOCATIONS
TYP.
STRUCTURAL DRAWINGS
TYP.
EQUAL
1 1/2 "
REVIEWED BY
LOCATIONS 1 1/2 "
DATE
3"
POST AT NUT
AT
5/8" HOLES IN 18"
GT
NUTS WHERE SHOWN. PROVIDE
DRAWN BY
(4) 1/2-13 WELD
TYP.
FOR
HSS4X4X1/4,
DESTINATION BY DESIGN
SEE DETAIL
6.13.2022 No.
HSS4X4X1/4 SIGN FRAME,
DETAIL 1/S1
FRAME ELEVATIONS
SIDES OF HSS FOR SIGN CONNECTION, TYP., SEE
SIGN POST AND
SCALE: 1 1/2" = 1'-0"
3/8"Ø HOLT THRU BOTH
LENOIR WAYFINDING SIGNAGE
TYPICAL POST WELDMENT
EQUAL
S4
VARIES (SEE ELEVATIONS)
1
FLUSH
DATE
GRIND 8-12
(8) #4 REBAR EQUALLY SPACED AS SHOWN ARETÉ ENGINEERS, PLLC 7668 Valley Blvd.
BUILT-UP SIGN #4 TIES AT 12" O/C
POST, SEE DETAILS
P.O. Box 745
(4) 1"Ø ANCHOR
Blowing Rock, NC 28605
BOLTS, SEE DETAIL
FIRM LICENSE No. P-1357 CYLINDRIAL CONCRETE
HEAVY HEX NUT BOTTOM AND SIDE OF 2'-6" DIAMETER
WITH JAM NUT
FOUNDATION SHALL BE CAST AGAINST RESIDUAL GRADE, NOT FILL
SHEET NUMBER 1 S5
TYPICAL SIGN FOUNDATION SCALE: 1" = 1'-0"
3 S5
TYPICAL ANCHOR BOLT DETAIL SCALE: 1 1/2" = 1'-0"
S5
AS NOTED
2963
SCALE
PROJECT No.
LENOIR, NC
BPM APPROVED BY
BPM
GT
REVISIONS
FOR
STRUCTURAL DRAWINGS
3" CLR.
LENOIR WAYFINDING SIGNAGE
24" 3" CLR.
3" CLR.
EMBEDMENT
DATE
ANCHOR BOLTS
MULTIPLE LOCATIONS
1"Ø F1554 GR.55
REVIEWED BY
ANCHOR
AT
BREAK-A-WAY
DRAWN BY
NCDOT APPROVED
DESTINATION BY DESIGN
5'-6" MIN.
1" THICK BASE PLATE
6.13.2022 No.
3" MIN.
S5
DETAILS
SCALE: 1" = 1'-0"
SIGN POST FOUNDATION
TYPICAL FOUNDATION SECTION
2 S5
2
DATE
FINISHED GRADE
FOUNDATION
Citywide Wayfinding Map
3
1
FIELD NOTES:
19 2
4
21 18
5
17 12
(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
£ ¤
15
321
N
WAYFINDING SYSTEM
16
Legend #
0
(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.
13
14
(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.
20 6-11
NOTES:
1
Project #: Drawn By: Checked By: Scale: Varies
Client:
Sign
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
2
Issue 1
136 Furman Rd.
Miles These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
USGS USGSThe TheNational NationalMap: Map:3D 3DElevation ElevationProgram. Program.USGS USGSEarth EarthResources ResourcesObservation Observation&&Science Science(EROS) (EROS) Center: GMTED2010. Data refreshed March, 2019. Center: GMTED2010. Data refreshed March, 2019.
Date June 2022
G-1
Citywide Wayfinding Matrix
CODE
SIGN TYPE
PRIMARY STREET
CROSS STREET
DIRECTION
SITE CONTENTS FRONT
SPEED LIMIT
45
1a
Major
HWY 321
North Main St
Southbound
S_Soccer Complex (GW)(MTN) S_Greenway (GW) R_Downtown
1b
Major
North Main St
HWY 321
Northbound
R_Aquatic Center (GW)(MTN) R_Soccer Complex (GW)(MTN) R_Greenway (GW)
45
L_Downtown L_JE Broyhill Park L_Community Gardens (GW)
45
1c
2a
2b
Major
Major
Major
HWY 321
Nuway Circ
HWY 321
North Main St
HWY 321
Greenhaven Dr & Nuway Cir
Northbound
Southbound
S_Downtown S_MLK Rec Center L_Library (GW)
Southbound
L_Greenway GW) L_Aquatic Center (GW)(MTN) R_MLK Rec Center
FIELD NOTES:
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
35
45
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
2c
Minor
Greenhaven Dr
HWY 321
Northbound
S_Aquatic Center (GW)(MTN) S_Greenway (GW) R_Soccer Complex (GW)(MTN)
2d
Major
HWY 321
Nuway Circ
Northbound
L_MLK Rec Center R_Aquatic Center (GW)(MTN) R_Soccer Complex (GW)(MTN)
45
3a
Major
Zack’s Fork Rd
HWY 321
Westbound
L_Downtown L_MLK Rec Center L_Greenway (GW)
35
25
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
WAYFINDING SYSTEM Project Project #: #: Drawn Drawn By: By: Checked Checked By: By: Scale: Scale: Varies Varies Issue Issue 11
Client: Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200 136 136 Furman Furman Rd. Rd.
These These drawings drawings are are meant meant for for DESIGN DESIGN INTENT INTENT ONLY. ONLY. Shop Shop drawings drawings and and details details must must be be submitted submitted to to this this office office for for approval approval prior prior to to fabrication. fabrication.
Date Date June June 2022 2022
Boone, Boone, NC NC 28607 28607 Ph: Ph: 828.386.1866 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-2
Citywide Wayfinding Matrix
CODE
SIGN TYPE
PRIMARY STREET
CROSS STREET
DIRECTION
SITE CONTENTS FRONT
SPEED LIMIT
3b
Major
Nuway Cir
Zack’s Fork Rd
Northbound
R_Mtn Bike Trails (MTN) R_Soccer Complex (GW)(MTN)
35
4a
Major
North Main St
North Main St
Southbound
S_Community Gardens (GW) L_Downtown L_JE Broyhill Park
45
S_Soccer Complex (GW)(MTN) S_Greenway (GW) R_JE Broyhill Park
45
4b
4c
5a
Major
Major
Minor
Creekway Dr
North Main Street
North Main St
North Main St
Creekway Dr/North Main St
Finley Ave
Northbound
Northbound
L_Community Gardens (GW) R_Aquatic Center (GW)(MTN) R_Soccer Complex (GW)(MTN)
Southbound
S_Downtown L_Freedman Center L_MLK Rec Center
FIELD NOTES:
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
35
20
(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
5b
Minor
North Main St
Finley Ave
Northbound
R_Freedman Center R_MLK Rec Center R_Aquatic Center (GW)(MTN)
5c
Minor
Finley Ave
North Main St
Westbound
L_Downtown L_Walker Stadium L_The Campus (GW)
25
6a
Minor
Harper Ave
Westbound
R_Downtown R_JE Broyhill Park R_The Campus (GW)
20
Norwood St/Ridge St
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.
20
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-3
Citywide Wayfinding Matrix
CODE
SIGN TYPE
PRIMARY STREET
CROSS STREET
DIRECTION
SITE CONTENTS FRONT
SPEED LIMIT
6b
Minor
Harper Ave
Norwood St/Ridge St
Eastbound
S_Greenway (GW) L_JE Broyhill Park
20
7a
Minor
Main St
Harper Ave
Southbound
S_Heritage Museum S_Walker Stadium S_The Campus (GW)
20
S_Hospital R_Walker Stadium
20
7b
7c
8a
Minor
Minor
Minor
Harper Ave
South Main St
Mulberry St
Main St/South Main St
College Ave
Harper Ave
Eastbound
Southbound
R_The Campus (GW) R_Community Gardens (GW)
Southbound
S_Hospital S_Mulberry Rec Center S_The Campus (GW)
FIELD NOTES:
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
20
20
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
8b
Minor
Harper Ave
Mulberry St
Eastbound
R_Hospital R_Mulberry Rec Center
8c
Minor
Mulberry St
College Ave
Northbound
S_Downtown L_The Campus (GW)
25
8d
Minor
Mulberry St
College Ave
Southbound
S_Hospital S_Mulberry Rec Center R_The Campus (GW)
25
25
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-4
Citywide Wayfinding Matrix
CODE
SIGN TYPE
PRIMARY STREET
CROSS STREET
DIRECTION
SITE CONTENTS FRONT
SPEED LIMIT
9
Minor
Ridge St
West Ave
Northbound
S_JE Broyhill Park L_Downtown L_The Campus (GW)
20
10
Minor
West Ave
Mulberry St
Westbound
L_Hospital L_Mulberry Rec Center L_The Campus (GW)
20
L_Heritage Museum L_Walker Stadium L_The Campus (GW)
20
11
12a
12b
Minor
Major
Major
West Ave
HWY 321
Wilkesboro Blvd
Main St
Wilkesboro Blvd
HWY 321
Westbound
Southbound
S_Visitor Center L_Civic Center R_Downtown
Eastbound
L_Greenway L_Aquatic Center (GW)(MTN) R_Visitor Center
FIELD NOTES:
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
45
45
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
12c
Major
HWY 321
Wilkesboro Blvd
Northbound
S_Aquatic Center (GW)(MTN) L_Downtown L_The Campus (GW)
12d
Major
Wilkesboro Blvd
HWY 321
Westbound
S_Downtown S_Greenway (GW) L_Visitor Center
45
13a
Minor
Mulberry St
Morganton Blvd/HWY 64
Southbound
S_Mulberry Rec Center S_TH Broyhill Walking Park (GW) S_Greenway (GW)
25
45
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-5
Citywide Wayfinding Matrix
CODE
SIGN TYPE
PRIMARY STREET
CROSS STREET
DIRECTION
SITE CONTENTS FRONT
SPEED LIMIT
13b-1
Major
Morganton Blvd/HWY 64
Mulberry St
Northbound
L_Downtown L_Hospital R_Mulberry Rec Center
45
13b-2
Major
Morganton Blvd/HWY 64
Mulberry St
Westbound
S_Aquatic Center (GW)(MTN) R_TH Broyhill Walking Park (GW) R_Greenway (GW)
45
Southbound
L_Mulberry Rec Center L_TH Broyhill Walking Park (GW) R_Downtown
45
13c
14a
14b
Major
Major
Major
Morganton Blvd/HWY 64
Creekway Dr
Harper Ave
Mulberry St
Harper Ave
Harper Ave
Southbound
L_Downtown L_The Campus (GW) L_Community Gardens (GW)
Northbound
S_Soccer Complex (GW)(MTN) R_Downtown R_Community Gardens (GW)
FIELD NOTES:
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
45
45
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
14c
Major
Harper Ave
Creekway Dr/Harper Ave
Southbound
R_Aquatic Center (GW)(MTN) R_Soccer Complex (GW)(MTN) R_Greenway (GW)
15a
Major
Harper Ave
Morganton Blvd/HWY 64
Southbound
L_Mulberry Rec Center L_TH Broyhill Walking Park (GW) L_Greenway (GW)
45
15b
Major
Morganton Blvd/HWY 64
Harper Ave
Eastbound
S_Mulberry Rec Center L_Downtown L_Soccer Complex (GW)(MTN)
50
35
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-6
Citywide Wayfinding Matrix
CODE
SIGN TYPE
PRIMARY STREET
CROSS STREET
DIRECTION
SITE CONTENTS FRONT
SPEED LIMIT
15c
Major
Harper Ave
Morganton Blvd/HWY 64
Northbound
S_Downtown S_Community Gardens (GW) R_Mulberry Rec Center
45
15d
Major
Morganton Blvd/HWY 64
Harper Ave
Westbound
R_Downtown R_Soccer Complex (GW)(MTN) R_Community Gardens (GW)
45
L_Chamber of Commerce L_Civic Center L_Visitor Center
45
16a
16b
17a
Major
Major
Major
HWY 321
HWY 321
Harper Ave
Civic Center Dr
Civic Center Dr
Morganton Blvd/HWY 64
Southbound
Northbound
S_Downtown S_The Campus (GW) L_Visitor Center
Eastbound
R_Greenway (GW) R_Mulberry Rec Center R_TH Broyhill Walking Park (GW)
FIELD NOTES:
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
45
45
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
17b
Major
Morganton Blvd/HWY 64
Harper Ave
Eastbound
L_Downtown L_The Campus (GW) R_Aquatic Center (GW)(MTN)
17c
Major
Harper Ave
Morganton Blvd/HWY 64
Westbound
S_Downtown L_Mulberry Rec Center L_TH Broyhill Walking Park (GW)
45
18a
Major
HWY 321
Hospital Ave
Southbound
L_Library (GW) R_Downtown R_The Campus (GW)
45
45
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-7
Citywide Wayfinding Matrix
CODE
SIGN TYPE
PRIMARY STREET
CROSS STREET
DIRECTION
SITE CONTENTS FRONT
SPEED LIMIT
18b
Major
HWY 321
Hospital Ave
Northbound
L_Downtown R_Library (GW) R_Greenway (GW)
45
19a
Major
Nuway Circ
Powell Rd
Southbound
S_Downtown L_Aquatic Center (GW)(MTN) L_Athletic Park (GW)
35
S_Soccer Complex (GW)(MTN) R_Aquatic Center (GW)(MTN) R_Athletic Park (GW)
35
19b
19c
20
21a
21b
Major
Minor
Minor
Major
Major
Nuway Circ
Powell Rd
Hospital Ave
Wilkesboro Blvd
Taylorsville Rd
Powell Rd
Nuway Circ
Harper Ave
Taylorsville Rd
Wilkesboro Blvd
Northbound
Westbound
L_Downtown L_MLK Rec Center R_Soccer Complex (GW)(MTN)
Southbound
R_Downtown R_JE Broyhill Park R_The Campus (GW)
FIELD NOTES:
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
25
25
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
Westbound
S_Downtown R_Aquatic Center (GW)(MTN) R_The Campus (GW)
45
Westbound
S_Aquatic Center (GW)(MTN) S_Greenway (GW) L_Downtown
35
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-8
*WILL REQUIRE 1 MINOR DIRECTIONAL SIGN ON COLLEGE AVE AND 1
Sign 1 a/b/c
ON BEALL ST
SIGN 1a SOCCER COMPLEX (GW)(MTB)
GREENWAY (GW)
Primary Street: HWY 321 Cross Street: North Main St Direction: Southbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
DOWNTOWN FIELD NOTES:
SIGN 1c Primary Street: HWY 321 Cross Street: North Main St Direction: Northbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
DOWNTOWN
JE BROYHILL PARK
*COMMUNITY GARDENS (GW)
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
SIGN 1b AQUATIC CENTER (GW)(MTB)
SOCCER COMPLEX (GW)(MTB)
GREENWAY (GW)
Primary Street: North Main St Cross Street: HWY 321 Direction: Northbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-9
Priority Placement Zone: 1 a/b/c
CLE NE WAY S ID E C IR
1a
FIELD NOTES:
£ ¤ 321
NOTES: BLO
£ ¤ 321
WIN
1c
GR OCK
BOU
(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
LEV
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.
ARD
(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
NW
1b
ET
H
ST
RE
ET
WAYFINDING SYSTEM
AB IZ EL
MAIN S TREE
T NW
(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
LEGEND:
Issue 1
136 Furman Rd.
Boone, NC 28607
Ph: 828.386.1866
PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Date June 2022
GRAPHIC LAYOUTS & LOCATIONS
G-10
Sign 2 a/b/c/d
SIGN 2a DOWNTOWN
MLK REC CENTER
Primary Street: Nuway Circ Cross Street: HWY 321 Direction: Southbound Speed Limit: 35 Sign Type: Major Letter Size: 5”
LIBRARY (GW)
SIGN 2c FIELD NOTES: Primary Street: Greenhaven Dr Cross Street: HWY 321 Direction: Northbound Speed Limit: 25 Sign Type: Minor Letter Size: 4”
AQUATIC CENTER (GW)(MTB)
MLK REC CENTER
GREENWAY (GW)
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
SOCCER COMPLEX (GW)(MTB)
SIGN 2b GREENWAY (GW)
AQUATIC CENTER (GW)(MTB)
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.
Primary Street: HWY 321 Cross Street: Nuway Circ/ Greenhaven Dr Direction: Southbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
SIGN 2d
WAYFINDING SYSTEM
MLK REC CENTER Primary Street: HWY 321 Cross Street: Nuway Circ Direction: Northbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
Project #: Drawn By: Checked By: Scale: Varies
Client:
AQUATIC CENTER (GW)(MTB)
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
SOCCER COMPLEX (GW)(MTB)
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-11
PO
E RO AD 1 523
Priority Placement Zone: 2 a/b/c/d
WE LL RO NE
S TAT
AD
2a 19b
BO
NUW
CK
UL
EV
AR
NOTES:
D
(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
£ ¤ 321
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
NW
RO
N DR IVE
G
2d
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
AV E
2b
IN
COURT
FIELD NOTES:
C E DA
ENH
OW
R RU N
GRE
BL
ELOT
AY C IRL
E NE
M CA
STRE
ET N E
2c
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
LEGEND:
Issue 1
136 Furman Rd.
Boone, NC 28607
Ph: 828.386.1866
PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Date June 2022
GRAPHIC LAYOUTS & LOCATIONS
G-12
Sign 3 a/b
SIGN 3a DOWNTOWN
MLK REC CENTER GREENWAY (GW)
Primary Street: Zack’s Fork Rd Cross Street: HWY 321 Direction: Westbound Speed Limit: 35 Sign Type: Major Letter Size: 5”
FIELD NOTES:
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
SIGN 3b Primary Street: Nuway Circ Cross Street: Zack’s Fork Rd Direction: Northbound Speed Limit: 35 Sign Type: Major Letter Size: 5”
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
MTN BIKE TRAILS (MTB)
WAYFINDING SYSTEM
SOCCER COMPLEX (GW)(MTB)
Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-13
Priority Placement Zone: 3 a/b KING SWOO CLE D CIR NE
3a
RK S FO K C ZA
ROA
D
FIELD NOTES:
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.
NU WA
(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
IRC YC LE
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
3b
NE
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
LEGEND:
Issue 1
136 Furman Rd.
Boone, NC 28607
Ph: 828.386.1866
PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Date June 2022
GRAPHIC LAYOUTS & LOCATIONS
G-14
SIGN 4a
*WILL REQUIRE 1 MINOR DIRECTIONAL SIGN ON COLLEGE AVE AND 1
Sign 4 a/b/c
ON BEALL ST
*COMMUNITY GARDENS (GW)
DOWNTOWN
Primary Street: North Main St Cross Street: North Main St Direction: Southbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
JE BROYHILL PARK FIELD NOTES:
SIGN 4c NOTES: *COMMUNITY GARDENS (GW) Primary Street: North Main St Cross Street: Creekway Dr/North Main St Direction: Northbound Speed Limit: 35 Sign Type: Major Letter Size: 5”
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.
AQUATIC CENTER (GW)(MTB)
SOCCER COMPLEX (GW)(MTB)
GREENWAY (GW)
JE BROYHILL PARK
(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
SIGN 4b SOCCER COMPLEX (GW)(MTB)
(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
Primary Street: Creekway Dr Cross Street: North Main St Direction: Northbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-15
Priority Placement Zone: 4 a/b/c
4a FIELD NOTES:
OL
D
NO
RT
H
RO
AD
NW
NOTES:
ST
AT
E
HI
GH
(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
W
AY
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
90
4c
WAYFINDING SYSTEM
AI
4b
N ST RE ET NW
E
AY
NW
M
CR
W EK
I DR
VE
Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
LEGEND:
Issue 1
136 Furman Rd.
Boone, NC 28607
Ph: 828.386.1866
PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Date June 2022
GRAPHIC LAYOUTS & LOCATIONS
G-16
Sign 5 a/b/c SIGN 5a DOWNTOWN
FREEDMAN CENTER
MLK REC CENTER
Primary Street: North Main St Cross Street: Finley Ave Direction: Southbound Speed Limit: 20 Sign Type: Minor Letter Size: 4”
FIELD NOTES:
SIGN 5c
Primary Street: Finley Ave Cross Street: North Main St Direction: Westbound Speed Limit: 25 Sign Type: Minor Letter Size: 4”
DOWNTOWN WALKER STADIUM
THE CAMPUS (GW)
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
SIGN 5b FREEDMAN CENTER MLK REC CENTER AQUATIC CENTER (GW)(MTB)
Primary Street: North Main St Cross Street: Finley Ave Direction: Northbound Speed Limit: 20 Sign Type: Minor Letter Size: 4”
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-17
Priority Placement Zone: 5 a/b/c
5a
FI
ST
RE
ET
NW
M AI N ST RE ET N W
FIELD NOTES:
E NL
Y
A
VE
NW
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.
VA
NC
E
5c
STAT E H IG H WAY 90
FIN LE Y AV E NW
(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
T NW
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
WAYFINDING SYSTEM
RIDGE
STREE
5b
Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
LEGEND:
Issue 1
136 Furman Rd.
Boone, NC 28607
Ph: 828.386.1866
PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Date June 2022
GRAPHIC LAYOUTS & LOCATIONS
G-18
Sign 6 a/b
SIGN 6a DOWNTOWN JE BROYHILL PARK THE CAMPUS (GW)
Primary Street: Harper Ave Cross Street: Norwood St/Ridge St Direction: Westbound Speed Limit: 20 Sign Type: Minor Letter Size: 4”
FIELD NOTES:
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.
SIGN 6b
Primary Street: Harper Ave Cross Street: Norwood St/Ridge St Direction: Eastbound Speed Limit: 20 Sign Type: Minor Letter Size: 4”
(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
GREENWAY (GW)
WAYFINDING SYSTEM
JE BROYHILL PARK
Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-19
Priority Placement Zone: 6 a/b
W
T ES
AV
E
RI
10
DG
6a E
ST
RE
HL
9
ET
EW IS
11
PR ICE ST
FIELD NOTES:
RE
8a
ET
R
E
NO
HA
AV
R PE
NOTES:
RW OO
6b
DS
7a
TR EE T
8b
8d
(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
RE E
WAYFINDING SYSTEM
ILL
ET
LL
AV
YH
RE
CO
E EG
OR
ST
CT
CH
RE
ET
IUR
SW
CH
ST
ET
RY
RE
ER
ST
LB
IN
7c
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.
MU
MA
7b
(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
PL AC E
Project #: Drawn By: Checked By: Scale: Varies
Client:
8c
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
LEGEND:
Issue 1
136 Furman Rd.
Boone, NC 28607
Ph: 828.386.1866
PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Date June 2022
GRAPHIC LAYOUTS & LOCATIONS
G-20
SIGN 7a HERITAGE MUSEUM
WALKER STADIUM
*THE CAMPUS (GW)
Sign 7 a/b/c
*WILL REQUIRE 2 MINOR SIGNS AT WILLOW ST & HARPER AVE **WILL REQUIRE 1 MINOR DIRECTIONAL SIGN ON COLLEGE AVE AND 1
ON BEALL ST
Primary Street: Main St Cross Street: Harper Ave Direction: Southbound Speed Limit: 20 Sign Type: Minor Letter Size: 4”
FIELD NOTES:
SIGN 7b
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
HOSPITAL
WALKER STADIUM
Primary Street: Harper Ave Cross Street: Main St/South Main St Direction: Eastbound Speed Limit: 20 Sign Type: Minor Letter Size: 4”
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
SIGN 7c
Primary Street: South Main St Cross Street: College Ave Direction: Southbound Speed Limit: 20 Sign Type: Minor Letter Size: 4”
*THE CAMPUS (GW)
**COMMUNITY GARDENS (GW)
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-21
Priority Placement Zone: 7 a/b/c
W
T ES
AV
E
RI
10
DG
6a E
ST
RE
HL
9
ET
EW IS
11
PR ICE ST
FIELD NOTES:
RE
8a
ET
R
E
NO
HA
AV
R PE
NOTES:
RW OO
6b
DS
7a
TR EE T
8b
8d
(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
RE E
WAYFINDING SYSTEM
ILL
ET
LL
AV
YH
RE
CO
E EG
OR
ST
CT
CH
RE
ET
IUR
SW
CH
ST
ET
RY
RE
ER
ST
LB
IN
7c
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.
MU
MA
7b
(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
PL AC E
Project #: Drawn By: Checked By: Scale: Varies
Client:
8c
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
LEGEND:
Issue 1
136 Furman Rd.
Boone, NC 28607
Ph: 828.386.1866
PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Date June 2022
GRAPHIC LAYOUTS & LOCATIONS
G-22
SIGN 8a HOSPITAL
MULBERRY REC CENTER
Sign 8 a/b/c/d
*WILL REQUIRE 2 MINOR SIGNS AT WILLOW ST & HARPER AVE
Primary Street: Mulberry St Cross Street: Harper Ave Direction: Southbound Speed Limit: 20 Sign Type: Minor Letter Size: 4”
*THE CAMPUS (GW)
SIGN 8c FIELD NOTES: Primary Street: Mulberry St Cross Street: College Ave Direction: Northbound Speed Limit: 25 Sign Type: Minor Letter Size: 4”
DOWNTOWN NOTES: *THE CAMPUS (GW)
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.
SIGN 8b
HOSPITAL MULBERRY REC CENTER
(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
Primary Street: Harper Ave Cross Street: Mulberry St Direction: Eastbound Speed Limit: 25 Sign Type: Minor Letter Size: 4”
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
SIGN 8d
Primary Street: Mulberry St Cross Street: College Ave Direction: Southbound Speed Limit: 25 Sign Type: Minor Letter Size: 4”
WAYFINDING SYSTEM
HOSPITAL
Project #: Drawn By: Checked By: Scale: Varies
Client:
MULBERRY REC CENTER
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
*THE CAMPUS (GW)
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-23
Priority Placement Zone: 8 a/b/c/d
W
T ES
AV
E
RI
10a
DG
6a E
ST
RE
HL
9
ET
EW IS
11
PR ICE ST
FIELD NOTES:
RE
8a
ET
10b
R
E
NO
HA
AV
R PE
NOTES:
RW OO
6b
DS
7a
TR EE T
8b
(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
MU
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
RE
7c E
WAYFINDING SYSTEM
ILL
ET
LL
AV
YH
RE
CO
E EG
OR
ST
CT
CH
RE
ET
IUR
SW
CH
ST
ET
RY
RE
ER
ST
LB
IN
7d
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.
8d
MA
7b
(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
PL AC E
Project #: Drawn By: Checked By: Scale: Varies
Client:
8c
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
LEGEND:
Issue 1
136 Furman Rd.
Boone, NC 28607
Ph: 828.386.1866
PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Date June 2022
GRAPHIC LAYOUTS & LOCATIONS
G-24
Sign 9
*WILL REQUIRE 2 MINOR SIGNS AT WILLOW ST & HARPER AVE
FIELD NOTES:
SIGN 9 NOTES: JE BROYHILL PARK DOWNTOWN *THE CAMPUS (GW)
Primary Street: Ridge St Cross Street: West Ave Direction: Northbound Speed Limit: 20 Sign Type: Minor Letter Size: 4”
(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-25
Priority Placement Zone: 9
W
T ES
AV
E
RI
10
DG
6a E
ST
RE
HL
9
ET
EW IS
11
PR ICE ST
FIELD NOTES:
RE
8a
ET
R
E
NO
HA
AV
R PE
NOTES:
RW OO
6b
DS
7a
TR EE T
8b
8d
(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
RE E
WAYFINDING SYSTEM
ILL
ET
LL
AV
YH
RE
CO
E EG
OR
ST
CT
CH
RE
ET
IUR
SW
CH
ST
ET
RY
RE
ER
ST
LB
IN
7c
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.
MU
MA
7b
(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
PL AC E
Project #: Drawn By: Checked By: Scale: Varies
Client:
8c
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
LEGEND:
Issue 1
136 Furman Rd.
Boone, NC 28607
Ph: 828.386.1866
PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Date June 2022
GRAPHIC LAYOUTS & LOCATIONS
G-26
Sign 10
*WILL REQUIRE 2 MINOR SIGNS AT WILLOW ST & HARPER AVE
SIGN 10 HOSPITAL MULBERRY REC CENTER *THE CAMPUS (GW)
Primary Street: West Ave Cross Street: Mulberry St Direction: Westbound Speed Limit: 20 Sign Type: Minor Letter Size: 4”
FIELD NOTES:
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-27
Priority Placement Zone: 10a
W
T ES
AV
E
RI
10
DG
6a E
ST
RE
HL
9
ET
EW IS
11
PR ICE ST
FIELD NOTES:
RE
8a
ET
R
E
NO
HA
AV
R PE
NOTES:
RW OO
6b
DS
7a
TR EE T
8b
8d
(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
RE E
WAYFINDING SYSTEM
ILL
ET
LL
AV
YH
RE
CO
E EG
OR
ST
CT
CH
RE
ET
IUR
SW
CH
ST
ET
RY
RE
ER
ST
LB
IN
7c
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.
MU
MA
7b
(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
PL AC E
Project #: Drawn By: Checked By: Scale: Varies
Client:
8c
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
LEGEND:
Issue 1
136 Furman Rd.
Boone, NC 28607
Ph: 828.386.1866
PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Date June 2022
GRAPHIC LAYOUTS & LOCATIONS
G-28
Sign 11
*WILL REQUIRE 2 MINOR SIGNS AT WILLOW ST & HARPER AVE
FIELD NOTES:
SIGN 11 HERITAGE MUSEUM WALKER STADIUM *THE CAMPUS (GW)
NOTES: Primary Street: West Ave Cross Street: Main St Direction: Westbound Speed Limit: 20 Sign Type: Minor Letter Size: 4”
(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-29
Priority Placement Zone: 11
W
T ES
AV
E
RI
10
DG
6a E
ST
RE
HL
9
ET
EW IS
11
PR ICE ST
FIELD NOTES:
RE
8a
ET
R
E
NO
HA
AV
R PE
NOTES:
RW OO
6b
DS
7a
TR EE T
8b
8d
(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
RE E
WAYFINDING SYSTEM
ILL
ET
LL
AV
YH
RE
CO
E EG
OR
ST
CT
CH
RE
ET
IUR
SW
CH
ST
ET
RY
RE
ER
ST
LB
IN
7c
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.
MU
MA
7b
(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
PL AC E
Project #: Drawn By: Checked By: Scale: Varies
Client:
8c
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
LEGEND:
Issue 1
136 Furman Rd.
Boone, NC 28607
Ph: 828.386.1866
PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Date June 2022
GRAPHIC LAYOUTS & LOCATIONS
G-30
Sign 12 a/b/c/d
SIGN 12a VISITOR CENTER CIVIC CENTER
DOWNTOWN
Primary Street: HWY 321 Cross Street: Wilkesboro Blvd Direction: Southbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
SIGN 12c FIELD NOTES: Primary Street: HWY 321 Cross Street: Wilkesboro Blvd Direction: Northbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
AQUATIC CENTER (GW)(MTB) DOWNTOWN
(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
THE CAMPUS (GW)
SIGN 12b
VISITOR CENTER
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.
GREENWAY (GW)
AQUATIC CENTER (GW)(MTB)
NOTES:
(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
Primary Street: Wilkesboro Blvd Cross Street: HWY 321 Direction: Eastbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
WAYFINDING SYSTEM
SIGN 12d Primary Street: Wilkesboro Blvd Cross Street: HWY 321 Direction: Westbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
DOWNTOWN GREENWAY (GW)
Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
VISITOR CENTER
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-31
Priority Placement Zone: 12 a/b/c/d
ABC COUR T NE
ING R OCK B OUL
E VA R
D
12a
TE
HW
12d
BLOW
S TA
FIELD NOTES:
Y9 0
HAR
PER
AV E
£ ¤ 321
17c S TA
12b
TE H WY
£ ¤
BOU RO O B KES WIL
LEV
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
NE ARD
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.
64
18
(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.
17b
(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
HICK
ORY B OUL
E VA R
D
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
12c
L
K IN
SI
DE
WAYFINDING SYSTEM
CT
Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
LEGEND:
Issue 1
136 Furman Rd.
Boone, NC 28607
Ph: 828.386.1866
PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Date June 2022
GRAPHIC LAYOUTS & LOCATIONS
G-32
Sign 13 a/b/c
*WILL REQUIRE 2 MINOR SIGNS AT THE END OF MULBERRY ST (ON NORWOOD ST)
AND AT LAKEWOOD CIRCLE
SIGN 13a MULBERRY REC CENTER *TH BROYHILL WALKING PARK (GW) GREENWAY (GW)
Primary Street: Mulberry St Cross Street: Morganton Blvd/HWY 64 Direction: Southbound Speed Limit: 25 Sign Type: Minor Letter Size: 4”
FIELD NOTES:
SIGN 13c MULBERRY REC CENTER Primary Street: Morganton Blvd/HWY 64 Cross Street: Mulberry St Direction: Southbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
*TH BROYHILL WALKING PARK (GW)
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.
DOWNTOWN
(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
SIGN 13b-1
SIGN 13b-2
DOWNTOWN
AQUATIC CENTER (GW)(MTB)
HOSPITAL
*TH BROYHILL WALKING PARK (GW)
MULBERRY REC CENTER
GREENWAY (GW)
Primary Street: Morganton Blvd/HWY 64 Cross Street: Mulberry St Direction: Northbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-33
Priority Placement Zone: 13 a/b/c
PA
RK
S
E TR
ET
SW
PE
N
O NT
N
A
S VE
W
13a M
13c
OR
G
T AN
ON
BO
E UL
VA
MU
£ ¤ 64
LB ER
£ ¤
RY
321
ST RE ET SW
ST
AT
E
G HI
HW
AY
RD
SW
FIELD NOTES:
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
18
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
MA
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
SW ET TRE IN S
13b-2
WAYFINDING SYSTEM
13b-1
Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
LEGEND:
Issue 1
136 Furman Rd.
Boone, NC 28607
Ph: 828.386.1866
PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Date June 2022
GRAPHIC LAYOUTS & LOCATIONS
G-34
*WILL REQUIRE 1 MINOR DIRECTIONAL SIGN ON COLLEGE AVE AND 1
SIGN 14a DOWNTOWN
**THE CAMPUS (GW)
*COMMUNITY GARDENS (GW)
Sign 14 a/b/c ON BEALL ST
**WILL REQUIRE 2 MINOR SIGNS AT WILLOW ST & HARPER AVE
Primary Street: Creekway Dr Cross Street: Harper Ave Direction: Southbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
FIELD NOTES:
SIGN 14c
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
Primary Street: Harper Ave Cross Street: Creekway Dr/Harper Ave Direction: Southbound Speed Limit: 35 Sign Type: Major Letter Size: 5”
AQUATIC CENTER (GW)(MTB) SOCCER COMPLEX (GW)(MTB) GREENWAY (GW)
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
SIGN 14b SOCCER COMPLEX (GW)(MTB)
DOWNTOWN
*COMMUNITY GARDENS (GW)
Primary Street: Harper Ave Cross Street: Harper Ave Direction: Northbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-35
14a
NW CLE TO R R E N C E CIR
CR EE KWAY DR IV E NW
Sign 14 a/b/c
HA
14c ST
A
H TE
W
8 Y1
BU
RP
E
V RA
EN
W
FIELD NOTES:
S
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
CO
LU
MB
US
ST
RE
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.
ET
SW
(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.
BRA
(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
DFO RD
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
STR EET SW
AB
WAYFINDING SYSTEM
IN GT
14b
ON RO AD
Project #: Drawn By: Checked By: Scale: Varies
NW
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
LEGEND:
Issue 1
136 Furman Rd.
Boone, NC 28607
Ph: 828.386.1866
PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Date June 2022
GRAPHIC LAYOUTS & LOCATIONS
G-36
*WILL REQUIRE 1 MINOR DIRECTIONAL SIGN ON COLLEGE AVE AND 1
SIGN 15a MULBERRY REC CENTER **TH BROYHILL WALKING PARK (GW) GREENWAY (GW)
Sign 15 a/b/c/d
ON BEALL ST
**WILL REQUIRE 2 MINOR SIGNS AT THE END OF MULBERRY ST (ON NORWOOD ST) Primary Street: Harper Ave Cross Street: Morganton Blvd/HWY 64 Direction: Southbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
SIGN 15c FIELD NOTES: Primary Street: Harper Ave Cross Street: Morganton Blvd/HWY 64 Direction: Northbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
DOWNTOWN
*COMMUNITY GARDENS (GW)
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
MULBERRY REC CENTER
SIGN 15b
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.
MULBERRY REC CENTER DOWNTOWN SOCCER COMPLEX (GW)(MTB)
(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
Primary Street: Morganton Blvd/HWY 64 Cross Street: Harper Ave Direction: Eastbound Speed Limit: 50 Sign Type: Major Letter Size: 5”
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
WAYFINDING SYSTEM
SIGN 15d Primary Street: Morganton Blvd/HWY 64 Cross Street: Harper Ave Direction: Westbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
DOWNTOWN SOCCER COMPLEX (GW)(MTB)
Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
*COMMUNITY GARDENS (GW)
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-37
HAR
PER
15a
AV E
Sign 15 a/b/c/d
RE DB
OL
D
H
AR
R PE
A RO
FIELD NOTES:
D
15d MOR
AR
S TAT E
HWY
UL ON BO T N A G
E VA R
18
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
NL
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.
£ ¤
E
(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
COM
SO UT HW EST BO UL EVA RD
AN
64
PLEX
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
STRE
15b
D SW
W ET S
WAYFINDING SYSTEM
15c
Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
LEGEND:
Issue 1
136 Furman Rd.
Boone, NC 28607
Ph: 828.386.1866
PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Date June 2022
GRAPHIC LAYOUTS & LOCATIONS
G-38
Sign 16 a/b
SIGN 16a CHAMBER OF COMMERCE
CIVIC CENTER
VISITOR CENTER
Primary Street: HWY 321 Cross Street: Civic Center Dr Direction: Southbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
FIELD NOTES:
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.
SIGN 16b
Primary Street: HWY 321 Cross Street: Civic Center Dr Direction: Northbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
DOWNTOWN
(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
THE CAMPUS (GW)
WAYFINDING SYSTEM
VISITOR CENTER
Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-39
HIC
CIV
IC
CE
NT
ER
DR
IVE
Priority Placement Zone: 16 a/b
KO RY BO
16a
UL EV
FIELD NOTES:
AR DD SW
£ ¤ 321
NOTES: HI
(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
CK OR YB
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.
OU LE VA RD
(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.
SE
(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
£ ¤ 321
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
16b
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
LEGEND:
Issue 1
136 Furman Rd.
Boone, NC 28607
Ph: 828.386.1866
PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Date June 2022
GRAPHIC LAYOUTS & LOCATIONS
G-40
Sign 17 a/b/c
*WILL REQUIRE 2 MINOR SIGNS AT THE END OF MULBERRY ST (ON NORWOOD ST)
SIGN 17a GREENWAY (GW) MULBERRY REC CENTER *TH BROYHILL WALKING PARK (GW)
Primary Street: Harper Ave Cross Street: Morganton Blvd/HWY 64 Direction: Eastbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
FIELD NOTES:
SIGN 17c Primary Street: Harper Ave Cross Street: Morganton Blvd/HWY 64 Direction: Westbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
DOWNTOWN
MULBERRY REC CENTER *TH BROYHILL WALKING PARK (GW)
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
SIGN 17b DOWNTOWN THE CAMPUS (GW)
AQUATIC CENTER (GW)(MTB)
Primary Street: Morganton Blvd/HWY 64 Cross Street: Harper Ave Direction: Eastbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-41
Priority Placement Zone: 17 a/b/c
VE NA O T N PEN
HAR
PER
AV E
NW
FIELD NOTES:
SW
17a NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
HAR
PER
17c AV E
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.
NW
(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.
12b
(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
SW
VA R D S W
17b
TO
NB
OU
RY BO ULE
LEV
AR
DS
W
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
H I C KO
AN
ST
RG
IFT
MO
THR
LEGEND:
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
Boone, NC 28607
Ph: 828.386.1866
PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Date June 2022
GRAPHIC LAYOUTS & LOCATIONS
G-42
Sign 18 a/b SIGN 18a LIBRARY (GW) DOWNTOWN THE CAMPUS (GW)
Primary Street: HWY 321 Cross Street: Hospital Ave Direction: Southbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
FIELD NOTES:
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
SIGN 18b Primary Street: HWY 321 Cross Street: Hospital Ave Direction: Northbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
DOWNTOWN
WAYFINDING SYSTEM
LIBRARY (GW)
GREENWAY (GW)
Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-43
Priority Placement Zone: 18 a/b
321 18a ¤ £
BLOW OUL OCK B ING R
FIELD NOTES: LIBRARY
E VA R
E AV L A PIT S HO
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
D (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.
S HO
PIT
A
V LA
EN
(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.
W
(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
£ ¤ 321
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
18b
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
LEGEND:
Issue 1
136 Furman Rd.
Boone, NC 28607
Ph: 828.386.1866
PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Date June 2022
GRAPHIC LAYOUTS & LOCATIONS
G-44
Sign 19 a/b/c SIGN 19a DOWNTOWN AQUATIC CENTER (GW)(MTB) ATHLETIC PARK (GW)
Primary Street: Nuway Circ Cross Street: Powell Rd Direction: Southbound Speed Limit: 35 Sign Type: Major Letter Size: 5”
FIELD NOTES:
SIGN 19c NOTES: Primary Street: Powell Rd Cross Street: Nuway Circ Direction: Westbound Speed Limit: 25 Sign Type: Minor Letter Size: 4”
DOWNTOWN MLK REC CENTER SOCCER COMPLEX (GW)(MTB)
(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
SIGN 19b SOCCER COMPLEX (GW)(MTB)
AQUATIC CENTER (GW)(MTB)
ATHLETIC PARK (GW)
Primary Street: Nuway Circ Cross Street: Powell Rd Direction: Northbound Speed Limit: 35 Sign Type: Major Letter Size: 5”
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-45
Priority Placement Zone: 19 a/b/c
19a
FIELD NOTES:
NOTES:
19c
E
L BE
P
C LA
(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
E
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.
FO
R D VI L L AG E
LE N E
AY C IRC
(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
LL RO
E RO AD 1 523
NE
NUW
AD
CAMELO
19b
WAYFINDING SYSTEM
T COURT
Project #: Drawn By: Checked By: Scale: Varies
Client:
S TAT
2b
CIRC
WE
2a
(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.
PO
LE N E
W
EX
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
LEGEND:
Issue 1
136 Furman Rd.
Boone, NC 28607
Ph: 828.386.1866
PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Date June 2022
GRAPHIC LAYOUTS & LOCATIONS
G-46
Sign 20
FIELD NOTES:
SIGN 20 DOWNTOWN
JE BROYHILL PARK THE CAMPUS (GW)
Primary Street: Hospital Ave Cross Street: Harper Ave Direction: Southbound Speed Limit: 25 Sign Type: Minor Letter Size: 4”
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-47
Priority Placement Zone: 20
W
LA
ND
PL
AC
E
NW
FIELD NOTES:
HO
SP
IT
AL
AV
E
NW
AB ER NATH Y ST RE ET NW
NE
HARPER
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT.
AV E
(2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS.
20
(3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION.
HA
(4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
RP
ER
AV
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
E
WAYFINDING SYSTEM Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
LEGEND:
Issue 1
136 Furman Rd.
Boone, NC 28607
Ph: 828.386.1866
PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Date June 2022
GRAPHIC LAYOUTS & LOCATIONS
G-48
Sign 21 a/b *WILL REQUIRE 1 MINOR SIGN ON LOWER CREEK DR AND 1 MINOR SIGN ON POWELL RD
SIGN 21a DOWNTOWN *AQUATIC CENTER (GW)(MTB) THE CAMPUS (GW)
Primary Street: Wilkesboro Blvd Cross Street: Taylorsville Rd Direction: Westbound Speed Limit: 45 Sign Type: Major Letter Size: 5”
FIELD NOTES:
NOTES: (1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS.
SIGN 21b Primary Street: Taylorsville Rd Cross Street: Wilkesboro Blvd Direction: Westbound Speed Limit: 35 Sign Type: Major Letter Size: 5”
(5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
AQUATIC CENTER (GW)(MTB)
WAYFINDING SYSTEM
GREENWAY (GW)
DOWNTOWN
Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
Issue 1
136 Furman Rd.
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Boone, NC 28607
Date June 2022
Ph: 828.386.1866
GRAPHIC LAYOUTS & LOCATIONS
G-49
Priority Placement Zone: 21 a/b
21a
TA YL OR SV
W
IL
KE
O SB
RO
BO
UL
A EV
RD
FIELD NOTES:
IL
NOTES:
LE RO AD
(1) PRIORITY PLACEMENT ZONES ARE FOR GENERAL LOCATIONS ONLY. FINAL SIGN PLACEMENT TO BE APPROVED BY NCDOT. (2) FINAL DESIGNS AND SHOP DRAWINGS SHALL BE SUPPLIED BY THE FABRICATOR FOR EACH OF THE BREAK-AWAY POLES IDENTIFIED AND A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER IS REQUIRED TO SIGN AND SEAL THE SUBMITTAL OF SHOP DRAWINGS. (3) FABRICATOR TO VERIFY THE MOUNTING CONDITIONS AND PROVIDE A DETAIL DRAWING FOR EACH MOUNTING SITUATION, PRIOR TO FABRICATION, FABRICATOR MUST OBTAIN APPROVAL FROM DESTINATION BY DESIGN (828-386-1866) FOR PLACEMENT PRIOR TO FABRICATION. (4) THE FABRICATOR SHALL BE FAMILIAR WITH ALL SITE CONDITIONS AND SHALL BE RESPONSIBLE FOR ALL UNDERGROUND UTILITY CHECKS. (5) WHERE RELOCATION IS NOT AN OPTION THE FABRICATOR WILL DEVELOP THE APPROPRIATE MOUNTING SOLUTION. THE SOLUTION SHALL MEET ALL ENGINEERING CRITERIA AS ESTABLISHED BY THE STANDARD FOOTINGS (WINDLOADS, SOILS, ETC.)
TA YL OR SV IL
21b
LE
WAYFINDING SYSTEM
RO AD
Project #: Drawn By: Checked By: Scale: Varies
Client:
CITY OF LENOIR 80 WEST AVE NW LENOIR, NC 28645 828.757.2200
LEGEND:
Issue 1
136 Furman Rd.
Boone, NC 28607
Ph: 828.386.1866
PRIORITY PLACEMENT ZONE 100’ TO 400’ FROM CROSS STREETS SEE SHEET C-1 FOR SIGN PLACEMENT GUIDELINES
These drawings are meant for DESIGN INTENT ONLY. Shop drawings and details must be submitted to this office for approval prior to fabrication.
Date June 2022
GRAPHIC LAYOUTS & LOCATIONS
G-50