PROJECT SATERN V PROJECT NAME: PROJECT LOCATION: ISSUE DATE: GROUP NAME: GROUP MEMBER: TUTOR NAME: SUBJECT NAME: SCHOOL NAME: SEMEESTER:
SATURN V 81/89 BOUVERIE ST, CARLTON VIC 2053 08/03/2018 DYNAMIC ARCHITECTS DANNY KWAK & JEAN VILJOEN EDWARD BERRY ARCH 1016 TECHNOLOGY 04 RMIT UNIVERSITY SEMESTER 1,2018
PROJECT SATURN V SHEET LIST WT A000 A001 A002 A100 A101 A102 A103 A104 A105 A106 A107 A108 A109 A110 A111 A112 A113 A114 A115 A116 A200 A201 A300 A301 A302 A304 A305 A400 A401 A402 A403 A404 A500 A510 A511 A600
Sheet Name TITLE SHEET SITE PLAN 01 SITE PLAN 02 BASEMENT FLOOR PLAN GROUND FLOOR PLAN LEVEL 01 PLAN LEVEL 02 PLAN LEVEL 03 PLAN LEVEL 04 PLAN LEVEL 05 PLAN LEVEL 06 PLAN LEVEL 07 PLAN LEVEL 08 PLAN LEVEL 09 PLAN ROOFTOP GARDEN PLAN ROOF PLAN REFLECTED CEILING PLAN 01 REFLECTED CEILING PLAN 02 REFLECTED CEILING PLAN 03 REFLECTED CEILING PLAN 04 ELEVATIONS ‐ NORTH & EAST ELEVATIONS ‐ SOUTH & WEST ZONE SECTIONS SECTION A SECTION B SECTION C SECTION D TYPICAL FACADE 01 TYPICAL FACADE 02 DETAIL 01 GLASS FLOOR DETAILS 02 STAIRS DETAILS 03 HANGING BOX TYPICAL AMENITIES PLAN TYPICAL AMENITIES ELEVATIONS 01 TYPICAL AMENITIES ELEVATION 02 SPECIAL DRAWINGS
Revision
SCALE
4
N/A
4
1:500
4
1:200
4
1:50
4
1:50
4
1:50
4
1:50
4
1:50
4
1:50
4
1:50
4
1:50
4
1:50
4
1:50
4
1:50
4
1:50
4
1:50
4
1:50
4
1:50
4
1:50
4
1:50
4
1:100
4
1:100
4
1:100
4
1:50
4
1:50
4
1:20
4
1:20
4
N/A
4
N/A
4
N/A
4
N/A
4
N/A
4
1:20
4
1:20
4
1:20
4
N/A
WALL SCHEDULE WT03 (INTERIOR) 230 BLOCK VENEER
WT 05 (INTERIOR) 200mm CONCRETE WALL
WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN
90mm MASONRY BLOCK 50mm RIGID INSULATION 80mm TIMBER BLOCK 10mm GYPSUM BOARD
150mm CONCRETE 40mm RIGID INSULATION 10mm GYPSUM BOARD
6mm LOW E COATED GLASS 12mm ARGON GAS 6mm LOW E COATED GLASS
WT02 (EXTERIOR) 270mm BRICK VENEER
WT 04 (INTERIOR) 300mm CONCRETE
WT 06 (INTERIOR) 90mm TIMBER STUD
WT08 (INTERIOR) 200mm FEATURE WALL
110mm MASONRY BRICK 40mm AIR GAP 40mm RIGID INSULATION 50mm TIMBER BLOCK 10mm PLYWOOD SUBSTRATE 20mm GYPSUM BOARD
10mm GYPSUM BOARD 40mm RIGID INSULATION 250mm POURED CONCRETE
10mm TIMBER CLADDING 20mm RIGID INSULATION 5mm AIR GAP 40mm TIMBER STUD 5mm AIR GAP 10mm TIMBER CLADDING
20mm TIMBER CLADDING 5mm AIR GAP 50mm RIGID INSULATION 100mm TIMBER STUD 5mm AIR GAP 20mm TIMBER CLADDING
DT 03 DOUBLE DOOR
DT 05 CURTAIN WALL (DOUBLE)
DT 07 TOILET DOOR
WT 01 (EXTERIOR) GLASS QUASI CURTAIN PANEL
DOOR SCHEDULE DT 01 SLIDING DOOR
GENERAL NOTES DT 02 SINGLE DOOR
DT 04 CURTAIN WALL (SINGLE)
1.
DT 06 FIRE EXIT DOOR
2. 3.
FLOOR SCHEDULE FT 01 150mm 6 CORE HC SLAB
FT 03 150mm GLASS FLOOR
FT 05 CAFE FLOOR 60x120mm PETITOT TILE
4.
30mm GLASS 50mm GLASS 50mm GLASS 20mm AIR GAP
5.
6. FT 02 300mm 4 CORE HC SLAB
FT 04 TOILET FLOOR 60x60mm OZ TILE
FT 06 CLASSROOM FLOOR 5mm SPHERA VINYL FLOOR
7. 8.
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS.CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
0
10
20
30
Notes:
40
4
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV
STATUS:
50
60
70
80
90
100
DESCRIPTION
PRELIMINARY
DATE
THE INTENT OF THE DRAWINGS AND SPECIFICATIONS IS TO PROVIDE FOR A WATERTIGHT & WEATHER TIGHT BUILDING. THE CONTRACTOR SHALL REVIEW ALL DETAILS RELATING TO THIS INTENT AND BY BIDDING OR ENTERING INTO THIS CONSTRUCTION CONTRACT WARRANTS FOR ONE FULL YEAR THE ADEQUACY OF THESE DETAILS. SHOULD THE CONTRACTOR TAKE EXCEPTION TO THESE DETAILS, SHALL NOTIFY THE ARCHITECT PRIOR TO BIDDING. ANY DEVIATION FROM THIS GENERAL INTENT SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION. THE INTENT OF THE DRAWINGS AND SPECIFICATIONS IS TO PROVIDE FOR A PLUMB, LEVEL, AND SQUARE STRUCTURE UNLESS OTHERWISE NOTED. ANY DEVIATION FROM THIS GENERAL INTENT SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION. THE BUILDING SHALL BE CONSTRUCTED IN FULL COMPLIANCE WITH ALL APPLICABLE CODES, ORDINANCES AND REGULATIONS AS WELL AS THE DRAWINGS AND SPECIFICATIONS. ANY CODE DEFICIENCIES IN THE DRAWINGS RECOGNIZED BY THE CONTRACTOR SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE PLACEMENT OF THE BUILDING ON THE SITE AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS. DISCREPANCIES BETWEEN DRAWINGS AND ACTUAL SITE CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE BIDDING THE PROJECT OR THE COMMENCEMENT OF WORK. THE OWNER SHALL NOT BE RESPONSIBLE FOR CHANGES TO THE WORK DUE TO THE FAILURE OF THE CONTRACTOR TO FAMILIARIZE HIMSELF WITH EXISTING CONDITIONS DO NOT SCALE DRAWINGS: ALL DIMENSIONS SHALL HAVE PREFERENCE OVER SCALE AND BE FIELD VERIFIED AND COORDINATED WITH WORK OF ALL TRADES. IF NO DIMENSIONS ARE GIVEN OR DISCREPANCIES FOUND, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT FOR CLARIFICATION BEFORE BIDDING OR COMMENCING THE WORK. DETAILS ARE INTENDED TO SHOW METHOD AND MANNER OF ACCOMPLISHING WORK. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, ALL INCLUDED AS PART OF THE WORK. THE CONTRACTOR SHALL PROVIDE ALL PERMITS AND INSPECTION NECESSARY FOR THE PROPER EXECUTION OF THE WORK IN ACCORDANCE WITH APPLICABLE CODES AND GOVERNING REGULATIONS. THE CONTRACTOR SHALL VERIFY THE SIZES AND LOCATIONS OF ALL MECHANICAL AND ELECTRICAL EQUIPMENT PADS AND BASES, AS WELL AS POWER, WATER AND DRAIN REQUIREMENTS FOR SUCH EQUIPMENT WITH EQUIPMENT MFG. DEVIATION OF THE AFOREMENTIONED REQUIREMENTS SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION.
DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
CLIENT:
SITE:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:
DYNAMIC ARCHITECTS
TITLE:
81/89 BOUVERIE ST, CARLTON VIC 3053
TITLE SHEET
SCALE AT A1:
DATE:
DRAWN:
As indicated 01.03.18 D.K & J.V PROJECT NO:
001
DRAWING NO:
A000
CHECKED:
E.B REVISION:
4
Notes: RY BAR
SURROUNDING TREE TYPES
EET STR
Quercus rubra: RED OAK
Angophora costata: SMOOTHBARKED APPLE
Ulmus x hollandica: ELM
Platanus x acerifolia: LONDON PLANES
Melia Azedarach: WHITE CEDAR
Corymbia ficifolia: RED FLOWERING GUM
QUEENS BERRY STREET
Flindersia australis: AUSTRALIAN TEAK
Celtis australis: WHITE CEDAR
EY KEL BER ON STR EET
4
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV DESCRIPTION
DATE
PRELIMINARY
STATUS:
ETH ZAB ELE
SWANS T
BOUVE RIE STR EET
LEICES TER ST
EET STR
REET
Eucalyptus leucoxylon: YELLOW GUM
DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
EET STR
CLIENT:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:
DYNAMIC ARCHITECTS TITLE:
SITE PLAN 01
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
SCALE AT A1:
1:500
PROJECT NO:
DATE:
1
1 : 500
0
10
20
CHECKED:
DRAWN:
01.03.18 D.K & J.V DRAWING NO:
001
SITE PLAN 01
NORTH
E.B REVISION:
4
A001 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
Notes: SITE ANALYSIS: NOTABLE BUILDINGS
3
1. 2. 3. 4. 5. 6. 7. 8. 9.
9 2
MELBOURNE & METROPOLITAN TRAMWAY BOARD FORMER PRIMARY SCHOOL NO.2363 MELBOURNE UNIVERSITY SCHOOL OF EDUCATION AUSTRALIAN MENUFACTURING WORKERS' UNION FORMER INDEPENDENT MISSION HALL PIXEL 205 SWANSTON SQUARE DEVELOPMENT SHOP (HO99) METROPOLITAN FIRE BRIGADE FIRE STATION NO.3
1 8
QUEENS BERRY STREET
4
5
BOUVE RIE STR EET
6 4
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV DESCRIPTION
DATE
PRELIMINARY
STATUS:
DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
CLIENT:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION
7
ARCHITECT:
DYNAMIC ARCHITECTS TITLE:
SITE PLAN 02
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
SCALE AT A1:
1:200 PROJECT NO:
1
SITE PLAN 02 1 : 200
DATE:
10
20
CHECKED:
DRAWN:
01.03.18 Author Checker DRAWING NO:
001 0
NORTH
REVISION:
4
A002 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
Notes: A200
DOOR TYPES
N
1
2
DT 01 SLIDING DOOR B
3
4
A302
5
6
DT 02 SINGLE DOOR
22804 500
4600
4600
4600
3927
3927
650 DT 03 DOUBLE DOOR
WT04
300
295
A
DT 04 CURTAIN WALL (SINGLE) DT 05 CURTAIN WALL (DOUBLE)
WT05
WORKSHOP TO BE EQUIPPED WITH SPECIALED MACHINES. REFER TO MANUFACTURE'S DETAIL
UP
3495
3000
SWITCHBOARD 07
DT 06 FIRE EXIT DOOR
DT 07 TOILET DOOR
WT04
FT02
470
B
400
400
WALL TYPES
WT 01 (EXTERIOR) GLASS QUASI
UP
WT04
D06
04
WT02 (EXTERIOR) 270mm BRICK VENEER
WORKSHOP
LOBBY 02
05 2175
FIRE ESCAPE STAIRS 02
WT03 (INTERIOR) 230 BLOCK VENEER
FT02 10772
FT02
16304
500
3000
WT 04 (INTERIOR) 300mm CONCRETE
WT 05 (INTERIOR) 200mm CONCRETE WALL
LIFT SERVICE D05
LOBBY FOR BIKE PARKING AND SERVICE LIFT
WT 06 (INTERIOR) 100mm TIMBER STUD
2000
A301
7807
A
WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN
BIKE STORAGE
FLOOR TYPES
06
W
E
A200
FT 01 150mm 6 CORE HC SLAB
FT02
C
FT 02 300mm 4 CORE HC SLAB
D01 LOBBY 01 03
WT06
WT06 D02
FT02
FT 03 150mm GLASS FLOOR
1905
DULE HEIGHT 10 BIKE PARKING. REFER TO MANUFACTURER'S DETAIL
WT04
FT04
FT 04 TOILET FLOOR
FT04 IN SHOWER ROOM TO SLOAP FOR WATERPROOFING
D07
4193
5325
LOCKERS AND BIKE EQUIPMENT TO REFER MANUFACTURER'S DETAIL
WT07
FT 05 CAFE FLOOR
SHOWERS FT04 D02
WT04
1880
5866
8084
02
FT 06 CLASSROOM FLOOR
D07
D WT04
D02
WT04
WT06
SUBSTATION
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18 DATE
PRELIMINARY
STATUS:
08
DYNAMIC ARCHITECTS
FT02 WT05 D06
PLANTS TO BE CONNECTED TO EACH FLOOR VIA SURVICE SHAFT, REFER TO PLAN
Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
D02 UP
4127
WT06
TOILET UNISEX
FT04
01 FIRE ESCAPE STAIRS 01
SERVICE SHAFT [MAIN]
UP
E
D07
D07
D07
D07
D07
FT04 TO BE WATERPROOFED IN TOILET AND SLOPE FOR WATER DRAIN
D07 D07
2804
WATER TANK FT02 09
D07 FT04
LIFT 02
4
REV DESCRIPTION
1880
LIFT 01
UP
A201
2602
WT08 (INTERIOR) 200mm FEATURE WALL
CLIENT:
UP
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:
300
336
RAINWATER APTURED ON ROOF TO BE RECYCLED THROUGH WATER TANK
1
BASEMENT 1 : 50
S A201
1000
200
DYNAMIC ARCHITECTS
6950
ROOM LEGEND 1. TOILET UNISEX 2. SHOWERS 3. LOBBY 01 4. LOBBY 02 5. WORKSHOP 6. BIKE STORAGE 7. SWITCH BOARD 8. SUBSTATION 9. RAINWATER TANK
TITLE:
BASEMENT FLOOR PLAN
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
SCALE AT A1:
1:50
PROJECT NO:
DATE:
10
20
CHECKED:
DRAWN:
01.03.18 D.K & J.V DRAWING NO:
001 0
NO RT H
E.B REVISION:
4
A100 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
Notes:
QUEENSBERRY STREET
DOOR TYPES
DT 01 SLIDING DOOR
A200 DT 02 SINGLE DOOR
N
1
2
500
B
3
4600
4600
295
DT 03 DOUBLE DOOR
6
3927
3927
DT 04 CURTAIN WALL (SINGLE)
940
WT02
REFER TO A200 FOR CURTAIN WALL TYPE
1
FT07
CW
DT 05 CURTAIN WALL (DOUBLE)
A600
DT 06 FIRE EXIT DOOR
D05
14
9
15
8
16
7
17
6
18
5
19
4
20
3
21
2
22
3
23
4
24
5
UP
FIRE ESCAPE STAIRS 02
WT05
WALL TYPES
D03
2
6
8 9
WT 05 (INTERIOR) 200mm CONCRETE WALL
11
CAFE FURNITURES TO BE POSITIONED TO ALLOW FREE FLOW MOVEMENT ACROSS SITE
7407
4000
LIFT SERVICE
8007
7807
OVERHEAD
A301
WORKSHOP EXHIBITION
MAIN FEATURE STAIRS
02
LOBBY
FT02 UP
14
WT05
15 16
CW
17
2541
2500
18
400
7454
W
21
CURTAIN WALL WITHIN BRICK VENEER WALL REFER TO DETAILS
C
22
3110
3793
3000
4193
D02
FT05
DW 6078
1800
2315
WT03
WT08 WT08
D03
LIFT 01
LIFT 02
CAFE KITCHEN 06 FT05
D02 CAFE COOL ROOM
2350
D
07
E
FT 02 300mm 4 CORE HC SLAB
A200
FT 03 150mm GLASS FLOOR
08 WT05
WT04 8
FT02
7
6
5
4
3
2
UP 10
200
11
2740
9
1
FT 06 CLASSROOM FLOOR 4
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV DESCRIPTION
DATE
PRELIMINARY
STATUS:
DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
FIRE ESCAPE STAIRS 01
D07
23 22 21
UP
SERVICE SHAFT [MAIN]
12
951
D07
D07
04 FT04
TOILET UNISEX
WT06
Disabled Toilet
CLIENT:
FT04 TOILET FLOOR TO BE WATERPROOFED AND SLOPED FOR DRAINAGE
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:
DYNAMIC ARCHITECTS
03
UP
9470
D02
FT04
D06
13 14 15 16 17 18 19 20
SERVICE SHAFT [WORKSHOP]
FT 05 CAFE FLOOR
WT05 24
2500
WT02
FT 04 TOILET FLOOR
REFUSE STORAGE UP
RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL
3596
DW
951
FT 01 150mm 6 CORE HC SLAB
05
1800
WT03
4127
LANSDOWNE PLACE
WT08
CAFE SERVICE
WT07
300
4014
S A201
GROUND FLOOR
FLOOR TYPES
FT05 CAFE FLOOR TO BE WATERPROOFED AND SLOPED FOR DRAINAGE
WT04
WT04
WT08 (INTERIOR) 200mm FEATURE WALL
24
D01
E
WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN
23
WT03
1 : 50
740
20
2103
1
400
19
2893
A201
1600
REFER TO A200 FOR CURTAIN WALL TYPE
FT07
13
WT 06 (INTERIOR) 100mm TIMBER STUD
TENSION WIRES TO SUPPORT MAIN FEATURE STAIRS AND HANDRAILS
01
WT02
WT 04 (INTERIOR) 300mm CONCRETE
10
12
A
WT03 (INTERIOR) 230 BLOCK VENEER
CURTAIN WALL WITHIN BLOCK VENEER WALL REFER TO DETAILS
VOID ABOVE REFER TO LEVEL 1 PLAN
7
10802
WT02 (EXTERIOR) 270mm BRICK VENEER
400
1
WT07
WT 01 (EXTERIOR) GLASS QUASI
WT07
21 11
D06
DT 07 TOILET DOOR
BOUVERIE STREET
1
D06
OVERHEAD
1500
B
D01
10
UP
WT07
13
2825
UP
11
56 50
WT 02 TO WRAP AROUND WT03 EXPOSING BRICK AND KEEPING BLOCKS INTERNAL
12
3000
5
4600
WT07
A
4
A302
300
1000
200
1645
970
955
970
2300
WT04
ROOM LEGEND 1. LOBBY 2. WORKSHOP EXHIBITION 3. TOILET UNISEX 4. TOILET DISABLED 5. CAFE SERVICE 6. CAFE KITCHEN 7. CAFE COOL ROOM 8. REFUSE STORAGE
TITLE:
GROUND FLOOR PLAN
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
SCALE AT A1:
1:50 PROJECT NO:
DATE:
10
20
CHECKED:
DRAWN:
01.03.18 D.K & J.V DRAWING NO:
001 0
NO RT H
E.B REVISION:
4
A101 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
Notes: DOOR TYPES
A200
DT 01 SLIDING DOOR
N
1
2
500
B
3
4600
4
A302
4600
5
4600
6
3927
3927
324
DT 02 SINGLE DOOR
617 DT 03 DOUBLE DOOR
WT02
CW
DT 04 CURTAIN WALL (SINGLE) DT 05 CURTAIN WALL (DOUBLE)
1032
2081
5
19
4
20
3
21
2
22
UP
CONCEALED MACHINE ROOM FOR VERTICAL WIND TUNNEL
FT03
1887
2
23 24
3
VOID
WT 01 (EXTERIOR) GLASS QUASI WT02 (EXTERIOR) 270mm BRICK VENEER
5
D06
6 7
9
3600
10000
7807
12
WT07
WT07
WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN
MEETING ROOM 01
MEETING ROOM 02
07
08
FT01
FT01
UP
13 14 15
2800
16
WT04
17 18 19
1802
CONCEALED MACHINE ROOM FOR VERTICAL WIND TUNNEL
W
WT 06 (INTERIOR) 100mm TIMBER STUD
2988
3200
WT 05 (INTERIOR) 200mm CONCRETE WALL
TENSION WIRES TO SUPPORT MAIN FEATURE STAIRS AND HANDRAILS
MAIN FEATURE STAIRS
FT02
D05
WT 04 (INTERIOR) 300mm CONCRETE
8983
11
VERTICAL WIND TUNNEL TEST ROOM TO BE EXPOSED REFER TO DETAIL
06 LIFT SERVICE
WT07
10
WORKSHOP
A301
WT03 (INTERIOR) 230 BLOCK VENEER
8
WT05
20 21
6030
CW
22
WT08 (INTERIOR) 200mm FEATURE WALL
FLOOR TYPES
E
A200
FT 01 150mm 6 CORE HC SLAB FT 02 300mm 4 CORE HC SLAB
23
D04
24
OVERHEAD
4130
400
7454
400
WT07
CORRIDOR 01 3110
4193
VERTICAL WIND TUNNEL TO BE LINKED WITH FLIGHT SIMULATOR MACHINES
D04
WORKSHOP TO BE EQUIPED WITH SPECIFIC MACHINERY. REFER TO FACULTY OFFICE
1785
C
04
D01
FT01
FT 03 150mm GLASS FLOOR
FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
FT 04 TOILET FLOOR
D04
4384
2190
FT 05 CAFE FLOOR
5956
FT 06 CLASSROOM FLOOR
3085
A201
WALL TYPES
BALUSTRADE AND HANDRAILS TO BE INSTALLED TO EDGE OF FT03
4
2988
FIRE ESCAPE STAIRS 02
1
REFER TO A200 FOR CURTAIN WALL TYPE
18
6450
17
6
HORIZONTAL CURTAIN PANELS AS CEILING FROM MAIN ENTRANCE
05
5132
7
CORRIDOR 02
5875
16
2950
8
3330
DT 07 TOILET DOOR
2875
15
2944
9
1793
14
1007
3000
10
1
2094
13
UP
B
2688
UP
11
DT 06 FIRE EXIT DOOR
FT03 GLASS FLOOR CANTERLEVERED TO HAVE BALUSTRADE
6887
12
A
REFER TO A200 FOR CURTAIN WALL TYPE
295
A
WT02
WT07
MEETING ROOM 03
OVERHEAD
D
WT08
09 FT01 LIFT 01
LIFT 02
D02
7
6
5
4
3
2
WT06
1
9 10 11
FIRE ESCAPE STAIRS 01
TOILET DISABLED
23 22 21
UP
SERVICE SHAFT [MAIN]
12
951
A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL
1
Level 1 1 : 50
RUBBISH CHUTE
200
2500
RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL
335
3943
336
1000
D07
FT04
01
TOILET FEMALE
D07
200
1900
TOILET MALE
02
Preliminary Design
22/03/18
1
Project Set Up
03/03/18 DATE
PRELIMINARY
FT04
100
2850
DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
FT04 TOILET FLOOR TO BE WATERPROOFED AND SLOPED FOR DRAINAGE CLIENT:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION
03
FT04
UP
6770
951
13 14 15 16 17 18 19 20
D07
2600
UP
WT05
270
2
D02
24
WT05
17/04/18
1300 UP
D02
WT05 D05
8
SERVICE SHAFT [WORKSHOP]
12/05/18
Mid Sem Presentation
STATUS:
4509 4127
9470
WT04
Final Package
3
REV DESCRIPTION
WT04
E
4
100
2056
534
FT04 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
ARCHITECT:
DYNAMIC ARCHITECTS
S A201
ROOM LEGEND 1. TOILET DISABLED 2. TOILET FEMALE 3. TOILET MALE 4. CORRIDOR 01 5. CORRIDOR 02 6. WORKSHOP 7. MEETING ROOM 01 8. MEETING ROOM 02 9. MEETING ROOM 03
TITLE:
LEVEL 01 PLAN
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
SCALE AT A1:
1:50 PROJECT NO:
DATE:
10
20
CHECKED:
DRAWN:
01.03.18 D.K & J.V DRAWING NO:
001 0
NO RT H
E.B REVISION:
4
A102 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
Notes: A200
DOOR TYPES
N
1
2
500
B
3
4600
4600
5
4600
WT 02 TO WRAP AROUND WT03 EXPOSING BRICK AND KEEPING BLOCKS INTERNAL
6
3927
3 A401
CW
3927
DT 04 CURTAIN WALL (SINGLE)
2
3
4
5
6
DN
1312
1057
1
12
UP
B
14
9
15
8
16
7
17
6
18
5
19
4
20
3
21
2
22
2
23
3
24
4
1
FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
DT 05 CURTAIN WALL (DOUBLE)
BALASTRADE TO BE INSTALLED ON HIGH POINT
DT 07 TOILET DOOR
DT 06 FIRE EXIT DOOR
10000
FT06
13
10
UP
05
CONCEALED MACHINE ROOM FOR VERTICAL WIND TUNNEL
WT05
9970
806
CORRIDOR 02
FT03
WALL TYPES
SLOPING FLOOR WITH LECTURE FURNITURES. UP
3000
11
DT 02 SINGLE DOOR
REFER TO A200 FOR CURTAIN WALL TYPE
FT06
WT03
DT 01 SLIDING DOOR
DT 03 DOUBLE DOOR
295
A
4
A302
FT03 GLASS PANELS TO BE LAYED OUT ACCORDING TO THE MANUFACTURER'S DETAIL. EDGE BEAMS TO JOIN ADJACENT WALLS
FIRE ESCAPE STAIRS 02
WT 01 (EXTERIOR) GLASS QUASI
1
WT02 (EXTERIOR) 270mm BRICK VENEER
5 6
WT03 (INTERIOR) 230 BLOCK VENEER
7 8 9
WT 04 (INTERIOR) 300mm CONCRETE
8000
11
LIFT SERVICE
8000
12
MAIN FEATURE STAIRS
TENSION WIRES TO SUPPORT MAIN FEATURE STAIRS AND HANDRAILS
13
UP
14 15
CONCEALED MACHINE ROOM FOR VERTICAL WIND TUNNEL
16 17 18
800
2700
19
3330
W
CW
20
1254
22
5880
C
9000
CORRIDOR 03
CORRIDOR 01
06
04
FT01
FT01
LECTURE ROOM FT06 1100
D01
FT 01 150mm 6 CORE HC SLAB FT 02 300mm 4 CORE HC SLAB
FT 03 150mm GLASS FLOOR FT 04 TOILET FLOOR FT 05 CAFE FLOOR
FLOOR HANGING FROM BEAM ABOVE AND SITTING ON TRUSES BELOW REFER TO DETAIL
WT06
FT 06 CLASSROOM FLOOR
400
WT08 6950
LIFT 02
MODULAR CURTAIN WALL REFER TO FACADE DETAIL
4
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV DESCRIPTION
DATE
PRELIMINARY
STATUS:
3000
1255
LIFT 01
200
3440
DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
WT07 D02 D06 8
WT05
7
6
5
4
3
2
1 24
9 10 11
FIRE ESCAPE STAIRS 01
12
951
TOILET MALE
23
01
22
UP 21
SERVICE SHAFT [MAIN]
FT04
FT04
TOILET FEMALE
03
6770
A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL
200
02
13 14 15 16 17 18 19 20
2500
RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL
S A201
MODULAR CURTAIN WALL TO HAVE OPAQUE GLASS
CLIENT:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION
FT04
300
951
RUBBISH CHUTE
TOILET DISABLED
D02
UP
SERVICE SHAFT [WORKSHOP]
D02
2500
UP
3000
4127
A200
5015
5000
WT07
1 : 50
E
5595
4614
VOID
WORKSHOP LEVELS DOUBLE HEIGHT
1
FLOOR TYPES
FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
07
3290
3000
4193
CURTAIN WALL WITHIN BRICK VENEER WALL REFER TO DETAILS
Level 2
WT08 (INTERIOR) 200mm FEATURE WALL
STEEL BEAM FROM FT03 TO JOIN INTO FT 05. REFER TO DETAIL
24
E
WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN
1000
23
D
WT 06 (INTERIOR) 100mm TIMBER STUD
21
WT04
UP
A201
WT 05 (INTERIOR) 200mm CONCRETE WALL
REFER TO A200 FOR CURTAIN WALL TYPE
A301
VERTICAL WIND TUNNEL TEST ROOM TO BE EXPOSED REFER TO MANUFACTURE'S DETAIL
7801
A
7807
10000
10
FT04 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
ARCHITECT:
DYNAMIC ARCHITECTS
ROOM LEGEND 1. TOILET DISABLED 2. TOILET FEMALE 3. TOILET MALE 4. CORRIDOR 01 5. CORRIDOR 02 6. CORRIDOR 03 7. LECTURE ROOM
TITLE:
LEVEL 02 PLAN
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
SCALE AT A1:
1:50 PROJECT NO:
DATE:
10
20
CHECKED:
DRAWN:
01.03.18 Author Checker DRAWING NO:
001 0
NO RT H
REVISION:
4
A103 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
Notes: DOOR TYPES
A200
DT 01 SLIDING DOOR
N
1
2
500
B
3
4600
4600
6
3927
DT 02 SINGLE DOOR
3927
DT 03 DOUBLE DOOR
4130
WT07
WT02
CW
REFER TO A200 FOR CURTAIN WALL TYPE
DT 04 CURTAIN WALL (SINGLE)
FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
295
A
5
4600
6000
WT02
4
A302
WT02
11
B C A304
2 A400
14
9
15
8
16
7
17
6
18
5
19
4
20
3
21
2
22
2
23
3
24
4
1
UP
FIRE ESCAPE STAIRS 02
DT 06 FIRE EXIT DOOR
CLASSROOM 01
10
DT 07 TOILET DOOR
07 FT06
FT03 GLASS PANELS TO BE LAYED OUT ACCORDING TO THE MANUFACTURER'S DETAIL. EDGE BEAMS TO JOIN ADJACENT WALLS
6408
WT03 400
A305
WT 02 TO WRAP D01 AROUND WT03 EXPOSING BRICK AND KEEPING BLOCKS INTERNAL
13
UP
3000
UP
D
12
DT 05 CURTAIN WALL (DOUBLE)
1
WALL TYPES
WT 01 (EXTERIOR) GLASS QUASI WT02 (EXTERIOR) 270mm BRICK VENEER
5
D06
6
WT03 (INTERIOR) 230 BLOCK VENEER
7
WT07
FT06
8 9
WT 04 (INTERIOR) 300mm CONCRETE
10
WT02
12
CLASSROOM 02 WT08
08
05
WORKSHOP
UP
OVERHEAD
15 16 17 18 19 20 21 22
CW
WT03
D01
A200
FT 01 150mm 6 CORE HC SLAB FT 02 300mm 4 CORE HC SLAB
FT 03 150mm GLASS FLOOR
FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
D03
FT 04 TOILET FLOOR
CORRIDOR 01
3000
4193
WT07
E
STEEL BEAM FROM FT03 TO JOIN INTO FT 05. REFER TO DETAIL
24
WORKSHOP TO BE EQUIPED WITH SPECIFIC MACHINERY. REFER TO FACULTY OFFICE
WT08 (INTERIOR) 200mm FEATURE WALL
FLOOR TYPES
23
400
C
LIGHT FITTING TO REFER CEILING PLAN AND MANUFACTURE'S DETAIL
13 14
W
WT 06 (INTERIOR) 100mm TIMBER STUD WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN
06 FT02
WT08
04
9470
FT 05 CAFE FLOOR
FT01 FT 06 CLASSROOM FLOOR
200 3700 1009
FT04
OVERHEAD
LIFT 01
LIFT 02
D07
D07
3168
03 3168
D
TOILET MALE
D02
WT04
6
5
4
3
9 10 11
2
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV DESCRIPTION
PRELIMINARY
STATUS:
MODULAR CURTAIN WALL REFER TO FACADE DETAIL
DATE
FIRE ESCAPE STAIRS 01
22 21
RUBBISH CHUTE
01
D07
D07
D07
D07
A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL
RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL
MODULAR CURTAIN WALL TO HAVE OPAQUE GLASS
CLIENT:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION
FT04
300
SERVICE SHAFT [WORKSHOP]
UP
SERVICE SHAFT [MAIN]
UP
WT05
TOILET DISABLED
23
13 14 15 16 17 18 19 20
E
FT04
02
Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
1
12
951
17/04/18
100
TOILET FEMALE
2500
7
24
1 : 50
12/05/18
Mid Sem Presentation
DYNAMIC ARCHITECTS
D02
UP
3000
4127
WT07 8
1
Final Package
3
D02
D06
Level 3
4
WT06
WT04
UP
A201
WT 05 (INTERIOR) 200mm CONCRETE WALL
FT06
FT03
CURTAIN WALL WITHIN BRICK VENEER WALL REFER TO DETAILS
TENSION WIRES TO SUPPORT MAIN FEATURE STAIRS AND HANDRAILS
8260
REFER TO A200 FOR CURTAIN WALL TYPE
D05
CORRIDOR 02
7407
7807
LIFT SERVICE
MAIN FEATURE STAIRS
7776
A A301
200
11
FT04 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
ARCHITECT:
DYNAMIC ARCHITECTS TITLE:
LEVEL 03 PLAN
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
S A201
ROOM LEGEND 1. TOILET DISABLED 2. TOILET FEMALE 3. TOILET MALE 4. CORRIDOR 01 5. CORRIDOR 02 6. WORKSHOP 7. CLASSROOM 01 8. CLASSROOM 02
SCALE AT A1:
1:50 PROJECT NO:
DATE:
10
20
CHECKED:
DRAWN:
01.03.18 Author Checker DRAWING NO:
001 0
NO RT H
REVISION:
4
A104 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
Notes: DOOR TYPES
A200
FT03 GLASS PANELS TO BE LAYED OUT ACCORDING TO THE MANUFACTURER'S DETAIL. EDGE BEAMS TO JOIN ADJACENT WALLS
N
1
2
500
4600
4
A302
4600
5
4600
6
3927
WT07
WT02
CW
3927
941
DT 02 SINGLE DOOR DT 03 DOUBLE DOOR
FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
REFER TO A200 FOR CURTAIN WALL TYPE
DT 04 CURTAIN WALL (SINGLE) DT 05 CURTAIN WALL (DOUBLE)
295
12
UP
11
13
WT04 TO CONNECT INTO ADJACENT MULLION
D04
14
A305
9
15
8
16
7
17
6
18
5
19
4
20
3
21
2
22
2
23
3
24
4
C A304
1
UP
DT 07 TOILET DOOR
D04 WT07
2000
WT07
UP
3000
10
D04
FT06
08
D
B
DT 06 FIRE EXIT DOOR
SEMINAR ROOMS
WT07
WALL TYPES
SEMINAR ROOMS'S WALL ATTACHED TO FLOOR ABOVE. REFER TO CEILING PLAN
5833
WT02
2051
A
B
3
DT 01 SLIDING DOOR
1
WT 01 (EXTERIOR) GLASS QUASI WT02 (EXTERIOR) 270mm BRICK VENEER
5
FIRE ESCAPE STAIRS 02
WT03 (INTERIOR) 230 BLOCK VENEER
6
2000
7 8
WT 04 (INTERIOR) 300mm CONCRETE
9 10 11
TENSION WIRES TO SUPPORT MAIN FEATURE STAIRS AND HANDRAILS
12
CLASSROOM 04 A
2000
A301
7807
LIFT SERVICE
CORRIDOR 02
FT03
WT02
WT08
MAIN FEATURE STAIRS
05
UP
WT05
07
WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN
LIGHT FITTING TO REFER CEILING PLAN AND MANUFACTURE'S DETAIL
13
2000
15
A404
WT 06 (INTERIOR) 100mm TIMBER STUD
FT06
14
2
WT 05 (INTERIOR) 200mm CONCRETE WALL
WT08 (INTERIOR) 200mm FEATURE WALL
16 17
FLOOR TYPES
18
W
7776
19 20
WT08
21
WT04
22 23 24
CORRIDOR 03 06
CURTAIN WALL WITHIN BRICK VENEER WALL REFER TO DETAILS
FLOOR HANGING FROM BEAM ABOVE AND SITTING ON TRUSES BELOW REFER TO DETAIL
FT01
CW
D03
CORRIDOR 01
2000
4193
2000
C
REFER TO A200 FOR CURTAIN WALL TYPE
A201
WT08
04 FT01
WT07 VOID
D02
1625
WORKSHOP LEVELS DOUBLE HEIGHT
D
WT06 LIFT 01
LIFT 02
UP
3000
4127
WT05
7
6
5
4
3
2
FT 04 TOILET FLOOR FT 05 CAFE FLOOR
FT 06 CLASSROOM FLOOR
4
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV DESCRIPTION
D07
DATE
PRELIMINARY
STATUS:
DYNAMIC ARCHITECTS
9
FIRE ESCAPE STAIRS 01
D07
23 22 21
UP
13 14 15 16 17 18 19 20
RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL
UP
RUBBISH CHUTE
S A201
UP
SERVICE SHAFT [MAIN]
Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
TOILET FEMALE
D02
1
12
951
D07
02
24
11
1 : 50
FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
FT04
10
1
FT 03 150mm GLASS FLOOR
D02
WT05
Level 4
FT 02 300mm 4 CORE HC SLAB
MODULAR CURTAIN WALL REFER TO FACADE DETAIL
D02
A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL
STEEL BEAM FROM FT03 TO JOIN INTO FT 05. REFER TO DETAIL
WT06
8
SERVICE SHAFT [WORKSHOP]
FT 01 150mm 6 CORE HC SLAB
FT04
WT04
WT07
E
A200
TOILET MALE 03
WT04 TO CONNECT INTO CORE WALL
E
TOILET DISABLED 01 FT04
D07
D07
D07
D07
MODULAR CURTAIN WALL TO HAVE OPAQUE GLASS
CLIENT:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION
FT04 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
ARCHITECT:
DYNAMIC ARCHITECTS
ROOM LEGEND 1. TOILET DISABLED 2. TOILET FEMALE 3. TOILET MALE 4. CORRIDOR 01 5. CORRIDOR 02 6. CORRIDOR 03 7. CLASSROOM 04 8. SEMINAR ROOMS
TITLE:
LEVEL 04 PLAN
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
SCALE AT A1:
1:50 PROJECT NO:
DATE:
10
20
CHECKED:
DRAWN:
01.03.18 Author Checker DRAWING NO:
001 0
NO RT H
REVISION:
4
A105 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
Notes: DOOR TYPES
A200 N
1
2
500
3
4600 3000
DT 01 SLIDING DOOR
4600
2
B
A402
A302
4
5
4600
6000
3927
1200
CW
3927
DT 02 SINGLE DOOR DT 03 DOUBLE DOOR
941
REFER TO A200 FOR CURTAIN WALL TYPE
DT 04 CURTAIN WALL (SINGLE)
FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
295
A
6
DT 05 CURTAIN WALL (DOUBLE) DT 06 FIRE EXIT DOOR
STUDENT LOUNGE 12
DT01
10
14
A305
9
15
8
16
7
17
6
18
5
19
4
20
1
3
21
A402
2
22
3000
3000
D
B
1
UP
FT06
DT 07 TOILET DOOR
WALL TYPES
WT03
WT 01 (EXTERIOR) GLASS QUASI
1 2
23
3
CORRIDOR 02
24
FIRE ESCAPE STAIRS 02
D05
3441
08
13
UP
UP
11
4 5
05
D06
6
FT03
WT02 (EXTERIOR) 270mm BRICK VENEER
WT08
WT08
CLASSROOM 06
WT03 (INTERIOR) 230 BLOCK VENEER
7
07 FT06
8 9
WT 04 (INTERIOR) 300mm CONCRETE
10 11 12
MAIN FEATURE STAIRS
8 A
A403
A301
6810
7807
LIFT SERVICE
TENSION WIRES TO SUPPORT MAIN FEATURE STAIRS AND HANDRAILS
WT 06 (INTERIOR) 100mm TIMBER STUD
WT07 UP
13
WORKSHOP
FT02 W
OVERHEAD
06
14 15 16 17 18 19
WT02
20
WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN
10743
REFER TO A200 FOR CURTAIN WALL TYPE
3 A402
A201
WT 05 (INTERIOR) 200mm CONCRETE WALL
FLOOR TYPES
E
CW
21
WT08 (INTERIOR) 200mm FEATURE WALL
A200
FT 01 150mm 6 CORE HC SLAB
22 23
C
FT 02 300mm 4 CORE HC SLAB
24
WT03 7
6
A403
A403
D03
CORRIDOR 01
3000
4193
WT07
04
DT01
FT 03 150mm GLASS FLOOR
FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
FT 04 TOILET FLOOR
WT08
FT 05 CAFE FLOOR
FT01
7100
FT 06 CLASSROOM FLOOR
WT02
D02
D LIFT 01
LIFT 02 3700
D07
UP 7
6
5
4
3
2
D07
1
UP
10 11
WT02
FIRE ESCAPE STAIRS 01
23
21
12 13 14 15 16 17 18 19 20
SERVICE SHAFT [WORKSHOP]
RUBBISH CHUTE
UP
SERVICE SHAFT [MAIN]
D07
D07
D07
A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL
1
Level 5 1 : 50
RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL
S A201
22/03/18
1
Project Set Up
03/03/18 DATE
PRELIMINARY
Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
D07
CLIENT:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION
01 FT04 300
WT04
UP
951
E
TOILET DISABLED
22
Preliminary Design
FT04 TOILET FLOOR TO BE WATERPROOFED AND SLOPED FOR DRAINAGE
02
24 9
2
DYNAMIC ARCHITECTS
FT04 TOILET FEMALE
D06 8
17/04/18
STATUS:
D02
WT05
12/05/18
Mid Sem Presentation
REV DESCRIPTION
D07
D02
WT04
Final Package
3
5768
3000
WORKSHOP TO BE EQUIPED WITH SPECIFIC MACHINERY. REFER TO FACULTY OFFICE
3168
03
OVERHEAD
4127
FT04 TOILET MALE
4
FT04 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
ARCHITECT:
DYNAMIC ARCHITECTS
ROOM LEGEND 1. TOILET DISABLED 2. TOILET FEMALE 3. TOILET MALE 4. CORRIDOR 01 5. CORRIDOR 02 6. WORKSHOP 7. LECTURE ROOM 8. STUDENT LOUNGE
TITLE:
LEVEL 05 PLAN
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
SCALE AT A1:
1:50 PROJECT NO:
DATE:
10
20
CHECKED:
DRAWN:
01.03.18 Author Checker DRAWING NO:
001 0
NO RT H
REVISION:
4
A106 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
Notes: DOOR TYPES
A200 DT 01 SLIDING DOOR
N
1
2
500
B
3
4600
4600
3000
4
A302
5
4600
6000
3927
1200
CW
3927
DT 02 SINGLE DOOR DT 03 DOUBLE DOOR
941
DT 04 CURTAIN WALL (SINGLE)
REFER TO A200 FOR CURTAIN WALL TYPE
2051
295
12
3000
13
10
14
9
15
8
16
7
17
6
18
5
19
4
20
3
21
2
22
1
UP
DT 06 FIRE EXIT DOOR
D04
DT 07 TOILET DOOR
OFFICE LOUNGE AREA WALL TYPES
2000
UP
11
B
DT 05 CURTAIN WALL (DOUBLE)
FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
UP
A
6
WT 01 (EXTERIOR) GLASS QUASI
1 2
CORRIDOR 02
23 24
4
05 FT03
FIRE ESCAPE STAIRS 02
WT02 (EXTERIOR) 270mm BRICK VENEER
3
5
WT03 (INTERIOR) 230 BLOCK VENEER
6
2000
7 8
WT 04 (INTERIOR) 300mm CONCRETE
9 10 11 12
8 A
MAIN FEATURE STAIRS
A403
2000
WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN
UP
13
OFFICE
14
2000
CORRIDOR 03 06
15
FT01
16
07
17
FT06
18 19
A201
W
20 21 22
WT08 (INTERIOR) 200mm FEATURE WALL
FLOOR TYPES
E
FT 01 150mm 6 CORE HC SLAB
A200
CW
FT 02 300mm 4 CORE HC SLAB
23
2000
400
C
WT 06 (INTERIOR) 100mm TIMBER STUD
LIFT SERVICE
REFER TO A200 FOR CURTAIN WALL TYPE
7807
A301
WT 05 (INTERIOR) 200mm CONCRETE WALL
TENSION WIRES TO SUPPORT MAIN FEATURE STAIRS AND HANDRAILS
24
7
6
A403
A403
FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
VOID 4193
CORRIDOR 01
FT 03 150mm GLASS FLOOR
D03
04 FT01
FT 04 TOILET FLOOR FT 05 CAFE FLOOR
OFFICE KITCHEN CORNER
3625
FT 06 CLASSROOM FLOOR
400
D02
D
FT04 TOILET MALE 03
LIFT 01
LIFT 02
D07
4
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV DESCRIPTION
D07
DATE
PRELIMINARY
STATUS:
3000 9500
DYNAMIC ARCHITECTS
D06 8
7
6
5
4
3
2
FT04 TOILET FEMALE
D02
UP
3000
4127
D02
FT04 TOILET FLOOR TO BE WATERPROOFED AND SLOPED FOR DRAINAGE
02
D07
1 24
9
UP
10 11
FIRE ESCAPE STAIRS 01
23
21
12 13 14 15 16 17 18 19 20
E 951
A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL
1
Level 6 1 : 50
RUBBISH CHUTE
RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL
UP
SERVICE SHAFT [WORKSHOP]
TOILET DISABLED
22
UP
SERVICE SHAFT [MAIN]
D07
D07
Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
D07
D07
CLIENT:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION
01 FT04
FT04 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
ARCHITECT:
DYNAMIC ARCHITECTS TITLE:
LEVEL 06 PLAN
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
S A201
ROOM LEGEND 1. TOILET DISABLED 2. TOILET FEMALE 3. TOILET MALE 4. CORRIDOR 01 5. CORRIDOR 02 6. CORRIDOR 03 7. OFFICE
SCALE AT A1:
1:50 PROJECT NO:
DATE:
10
20
CHECKED:
DRAWN:
01.03.18 Author Checker DRAWING NO:
001 0
NO RT H
REVISION:
4
A107 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
Notes: DOOR TYPES
A200
DT 01 SLIDING DOOR
N
1
2
500
B
3
4600
4600
WT02
4
A302
5
4600
3927
WT02
WT07
3927
DT 02 SINGLE DOOR
941
DT 03 DOUBLE DOOR
REFER TO A200 FOR CURTAIN WALL TYPE
DT 04 CURTAIN WALL (SINGLE) DT 05 CURTAIN WALL (DOUBLE)
FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
295
CW
A
6
REF. DW
DT 06 FIRE EXIT DOOR
WT02 12
B
14
9
15
8
16
7
17
6
18
5
19
4
20
3
21
2
22
1
UP
FIRE ESCAPE STAIRS 02
D01
DT 07 TOILET DOOR
2950
3000
WT07
13
10
KITCHEN
PHD RESERACH ROOM KITCHEN AREA
09
CORRIDOR 02
1712
WALL TYPES
FT06
05 UP
UP
11
WT 01 (EXTERIOR) GLASS QUASI
1
FT03
2
23
3
24
4
D03
WT02 (EXTERIOR) 270mm BRICK VENEER
5
D06
6
WT03 (INTERIOR) 230 BLOCK VENEER
7
WT02
8 9
WT 04 (INTERIOR) 300mm CONCRETE
10 11 12
7807
A301
LIFT SERVICE
PHD ROOM
8037
MAIN FEATURE STAIRS
A
07
WT 05 (INTERIOR) 200mm CONCRETE WALL
TENSION WIRES TO SUPPORT MAIN FEATURE STAIRS AND HANDRAILS
WT 06 (INTERIOR) 100mm TIMBER STUD
FT06
REFER TO A200 FOR CURTAIN WALL TYPE
WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN
UP
13
WORKSHOP 06 FT02 A201
W
OVERHEAD
14 15 16 17 18 19 20
D03
21 22
WT08 (INTERIOR) 200mm FEATURE WALL
FLOOR TYPES
E
A200
FT 01 150mm 6 CORE HC SLAB
CW FT 02 300mm 4 CORE HC SLAB
23
C
24
WT07
CORRIDOR 01
LOUNGE
04 FT01
08 FT01
FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
5820
4193
D01
FT 03 150mm GLASS FLOOR FT 04 TOILET FLOOR FT 05 CAFE FLOOR
PHD RESERACH ROOM WAITING AREA
FT 06 CLASSROOM FLOOR
WT02
D OVERHEAD
LIFT 01
LIFT 02
4
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV DESCRIPTION
PRELIMINARY
STATUS:
WT07
DYNAMIC ARCHITECTS
D02
D02
D02
D06 7
6
5
4
3
2
1
TOILET DISABLED
24 9
UP
10 11
WT02
22 21
13 14 15 16 17 18 19 20
951
SERVICE SHAFT [WORKSHOP]
RUBBISH CHUTE
RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL
UP
WT04
A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL
1 : 50
23
12
E
1
FIRE ESCAPE STAIRS 01
S A201
UP
SERVICE SHAFT [MAIN]
01 FT04
D07
D07 FT04
TOILET FEMALE 02
D07 FT04
TOILET MALE 03
3017
8
Level 7
Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
UP
4127
WORKSHOP TO BE EQUIPED WITH SPECIFIC MACHINERY. REFER TO FACULTY OFFICE
DATE
FT04 TOILET FLOOR TO BE WATERPROOFED AND SLOPED FOR DRAINAGE CLIENT:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION
FT04 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
ARCHITECT:
DYNAMIC ARCHITECTS
ROOM LEGEND 1. TOILET DISABLED 2. TOILET FEMALE 3. TOILET MALE 4. CORRIDOR 01 5. CORRIDOR 02 6. WORKSHOP 7. PHD ROOM 8. LOUNGE 9. KITCHEN
TITLE:
LEVEL 07 PLAN
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
SCALE AT A1:
1:50 PROJECT NO:
DATE:
10
20
CHECKED:
DRAWN:
01.03.18 Author Checker DRAWING NO:
001 0
NO RT H
REVISION:
4
A108 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
Notes: DOOR TYPES
A200 DT 01 SLIDING DOOR
N
1
2
500
B
3
4600
4
A302
4600
5
4600
3927
A
3927
DT 03 DOUBLE DOOR
941
DT 04 CURTAIN WALL (SINGLE)
REFER TO A200 FOR CURTAIN WALL TYPE
DT 05 CURTAIN WALL (DOUBLE)
FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
295
CW
DT 02 SINGLE DOOR
6
REF. DW
DT 06 FIRE EXIT DOOR
12
9
15
8
16
7
17
6
18
5
19
4
20
3
21
1
2
22
2
2
23
3
3
24
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
FIRE ESCAPE STAIRS 02
A301
7807
A
LIFT SERVICE
FT03
GLASS BOX TO BE SUPPORTED WITH TENSION WIRE ATTACHED TO FLOOR ABOVE. REFER TO DETAIL
TENSION WIRE TO SUPPORT STAIRS AND ACT AS HANDRAILS
966
MAIN FEATURE STAIRS
1
WT02 (EXTERIOR) 270mm BRICK VENEER WT03 (INTERIOR) 230 BLOCK VENEER
WT 04 (INTERIOR) 300mm CONCRETE
MAIN FEATURE STAIRS
WT 05 (INTERIOR) 200mm CONCRETE WALL
TENSION WIRES TO SUPPORT MAIN FEATURE STAIRS AND HANDRAILS
STUDENT LOUNGE
WT 06 (INTERIOR) 100mm TIMBER STUD
07 WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN
FT06
FT01 UP
UP
13
A201
WT 01 (EXTERIOR) GLASS QUASI
CORRIDOR 03 06
WALL TYPES
W
C
13
14
14
15
15
16
16
17
17
18
18
19
19
20
20
21
21
22
22
23
23
24
24
WT08 (INTERIOR) 200mm FEATURE WALL
16807
UP
1712
05
7807
1
CORRIDOR 02
UP
3000
14
WT07 TO ATTACH ADJACENT MULLION
STUDENT LOUNGE KITCHEN AREA TO BE WATERPROOFED AND SLOPED FOR DRAINAGE
D01
10
UP
B
DT 07 TOILET DOOR
13
REFER TO A200 FOR CURTAIN WALL TYPE
UP
11
FLOOR TYPES
E
FT 01 150mm 6 CORE HC SLAB
A200
FT 02 300mm 4 CORE HC SLAB
CW FT 03 150mm GLASS FLOOR
CORRIDOR 01 D01
4193
04
FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
DW REF.
VOID
FT 04 TOILET FLOOR FT 05 CAFE FLOOR
STUDENT LOUNGE FURNITURES TO REFER MANUFACTURE'S DETAIL
FT01
FT 06 CLASSROOM FLOOR
WORKSHOP LEVELS DOUBLE HEIGHT
D LIFT 01
4
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV DESCRIPTION
LIFT 02
PRELIMINARY DYNAMIC ARCHITECTS
D02
D02
D02
7
6
5
4
3
2
1
TOILET DISABLED
24 9
UP
10
FIRE ESCAPE STAIRS 01
11
23
21
12
RUBBISH CHUTE
UP
SERVICE SHAFT [MAIN]
D07
D07 FT04
02
TOILET MALE D07 FT04
03
S A201
1
Level 8 1 : 50
FT04 TOILET FLOOR TO BE WATERPROOFED AND SLOPED FOR DRAINAGE CLIENT:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION
FT04
300
951
13 14 15 16 17 18 19 20
UP
SERVICE CHUTE [WORKSHOP]
01
22
TOILET FEMALE
3017
D06 8
E
Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
UP
3000
4127
STATUS:
WT07 TO CONNECT INTO WT04 CORE
DATE
FT04 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
ARCHITECT:
DYNAMIC ARCHITECTS
ROOM LEGEND 1. TOILET DISABLED 2. TOILET FEMALE 3. TOILET MALE 4. CORRIDOR 01 5. CORRIDOR 02 6. CORRIDOR 03 7. STUDENT LOUNGE
TITLE:
LEVEL 08 PLAN
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
SCALE AT A1:
1:50 PROJECT NO:
DATE:
10
20
CHECKED:
DRAWN:
01.03.18 Author Checker DRAWING NO:
001 0
NO RT H
REVISION:
4
A109 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
Notes: DOOR TYPES
A200
DT 01 SLIDING DOOR
N
1
2
500
B
3
4600
4
A302
4600
5
4600
6
3927
3927
DT 02 SINGLE DOOR
941 DT 03 DOUBLE DOOR
CW
DT 05 CURTAIN WALL (DOUBLE)
FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
295
A
DT 04 CURTAIN WALL (SINGLE)
REFER TO A200 FOR CURTAIN WALL TYPE
DT 06 FIRE EXIT DOOR
12
9
15
8
16
7
17
6
18
5
19
4
20
3
21
1
2
22
2
22
23
3
21
24
4
20
5
19
6
18
7
17
8
16
9
15
10
14
11
13
1
UP
9770
FIRE ESCAPE STAIRS 02
2030
05 FT03
1900 WALL TYPES
24
D06
UP
3000
DT 07 TOILET DOOR
CORRIDOR 02
D01
14
UP
B
13
10
986
WT 01 (EXTERIOR) GLASS QUASI
23
WT02 (EXTERIOR) 270mm BRICK VENEER WT03 (INTERIOR) 230 BLOCK VENEER
WT 04 (INTERIOR) 300mm CONCRETE
DW
UP
11
12
7807
WORKSHOP
FT06 UP
OVERHEAD 1132
UP
400
C
11
14
10
15
9
16
8
17
7
18
6
19
5
20
4
21
3
22
2
23
DW
12 13
W
07
06 FT02
A201
STUDENT LOUNGE
WT07
WT 05 (INTERIOR) 200mm CONCRETE WALL
TENSION WIRES TO SUPPORT MAIN FEATURE STAIRS AND HANDRAILS
REFER TO A200 FOR CURTAIN WALL TYPE
A301
LIFT SERVICE
MAIN FEATURE STAIRS
8207
A
MAIN FEATURE STAIRS
7807
WT07
WT 06 (INTERIOR) 100mm TIMBER STUD WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN
WT08 (INTERIOR) 200mm FEATURE WALL
FLOOR TYPES
CW
E
2000
A200
STUDENT LOUNGE KITCHEN AREA TO BE WATERPROOFED AND SLOPED FOR DRAINAGE
FT 01 150mm 6 CORE HC SLAB FT 02 300mm 4 CORE HC SLAB
1
UP
24
FT 03 150mm GLASS FLOOR
FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
CORRIDOR 01 04
FT 04 TOILET FLOOR
3793
4193
D01 FT 05 CAFE FLOOR
WT04 FT 06 CLASSROOM FLOOR
400
WT03
D
OVERHEAD
LIFT 01
WIRES TO BE USED AS SPACE DIVIDER
LIFT 02
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV DESCRIPTION
DATE
PRELIMINARY
STATUS:
WT06
WT04
4
3426
D02
8
WT05
7
6
5
4
3
2
1
UP
11
FIRE ESCAPE STAIRS 01
23 22 21
12
951
WT04
1 : 50
SERVICE SHAFT [WORKSHOP]
RUBBISH CHUTE
RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL
UP
1451
13 14 15 16 17 18 19 20
A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL
1
TOILET DISABLED
24 9 10
Level 9
D02
D06
WT04
E
D02
Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
UP
4127
DYNAMIC ARCHITECTS
UP
SERVICE SHAFT [MAIN]
01
D07
D07 FT04
TOILET FEMALE 02
D07
TOILET MALE
FT04
03
FT04 TOILET FLOOR TO BE WATERPROOFED AND SLOPED FOR DRAINAGE CLIENT:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION
FT04
FT04 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
ARCHITECT:
DYNAMIC ARCHITECTS
S A201
ROOM LEGEND 1. TOILET DISABLED 2. TOILET FEMALE 3. TOILET MALE 4. CORRIDOR 01 5. CORRIDOR 02 6. WORKSHOP 7. STUDENT LOUNGE
TITLE:
LEVEL 09 PLAN
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
SCALE AT A1:
1:50 PROJECT NO:
DATE:
10
20
CHECKED:
DRAWN:
01.03.18 Author Checker DRAWING NO:
001 0
NO RT H
REVISION:
4
A110 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
Notes: DOOR TYPES
A200
FT03 GLASS PANELS TO BE LAYED OUT ACCORDING TO THE MANUFACTURER'S DETAIL. EDGE BEAMS TO JOIN ADJACENT WALLS
N
1
2
518
4600
5
4600
3927
WT02
WT07
6 3927
DT 03 DOUBLE DOOR DT 04 CURTAIN WALL (SINGLE)
REFER TO A200 FOR CURTAIN WALL TYPE
CW
250
DT 06 FIRE EXIT DOOR
WT07 DT 07 TOILET DOOR
2367
3000
2825
1300
DT 05 CURTAIN WALL (DOUBLE)
FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
D01 CORRIDOR 02
FT03 GLASS PANELS TO BE LAYED OUT ACCORDING TO THE MANUFACTURER'S DETAIL. EDGE BEAMS TO JOIN ADJACENT WALLS
WT03
24
400
2795
232
05
WT07
UP
B
DT 02 SINGLE DOOR
941
585
535
4
A302
4600
WT02
A
B
3
DT 01 SLIDING DOOR
23
WALL TYPES
WT 01 (EXTERIOR) GLASS QUASI
22
WT02 (EXTERIOR) 270mm BRICK VENEER
21
2376
20
WT07
19
WT03 (INTERIOR) 230 BLOCK VENEER
17
ROOFTOP GLASS PANELS TO BE WATERPROOFED REFER TO ROOF PLAN
12
UP
11
CW
9 8 7 6
STEEL BEAMS AS RAFTERS
W
5
WT07
4 3
WT02
232
1
400
VOID
2795
WT03
04
3310
3110
D01
FT01
WT07
E
FLOOR TYPES
FT 01 150mm 6 CORE HC SLAB
A200
FT 02 300mm 4 CORE HC SLAB
FT 03 150mm GLASS FLOOR
FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE
FT 04 TOILET FLOOR FT 05 CAFE FLOOR
WATER TO FLOW ONTO EXTERIOR SIDE OF WT01 THEN DRIP DOWN
232
1300
4193
CORRIDOR 01
WT08 (INTERIOR) 200mm FEATURE WALL
ROOFTOP GARDEN PLANTING TO REFER LANDSCAPE ARCHITECT'S PLAN
STEEL BEAM FROM FT03 TO JOIN INTO FT 05. REFER TO DETAIL
2376
C
2
WT 06 (INTERIOR) 100mm TIMBER STUD WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN
10
WT07
WT 05 (INTERIOR) 200mm CONCRETE WALL
FT01
2376
1300
FT01
07
232
747
06
ROOFTOP GARDEN
WT 04 (INTERIOR) 300mm CONCRETE
TENSION WIRES TO SUPPORT MAIN FEATURE STAIRS AND HANDRAILS
REFER TO A200 FOR CURTAIN WALL TYPE
WT07
2376
MAIN FEATURE STAIRS
CORRIDOR 03
A201
8194
13
7407
14
7407
1300
7807
232
15
A A301
WATER TO FLOW ONTO EXTERIOR SIDE OF WT01 THEN DRIP DOWN
16
OVERHEAD
WT07
747
1300
18
FT 06 CLASSROOM FLOOR
WT03
1509
LIFT 01
LIFT 02 WT04
2815
250
2738
WT05
7
6
5
4
3
2
1
9
UP
10
2347
11
FIRE ESCAPE STAIRS 01
23 22 21
12 13 14 15 16 17 18 19 20
951
RUBBISH CHUTE
UP
SERVICE SHAFT [WORKSHOP]
232
12/05/18
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
UP
SERVICE SHAFT [MAIN]
01 FT04 WT05
PRELIMINARY
STATUS:
MODULAR CURTAIN WALL REFER TO FACADE DETAIL
DATE
D02
TOILET FEMALE 02
TOILET DISABLED
24
WT07
2756
D02
WT05
UP 8
Final Package
3
DYNAMIC ARCHITECTS
D06
E
241
D02 3000
1300
4127
WT07
OVERHEAD
WT06
814
1873
WT07
WORKSHOP LEVELS DOUBLE HEIGHT
4
REV DESCRIPTION
250
2795
D
PERGOLAR TO PROVIDE SHADE REFER TO ROOF PLAN
2367
WT07
D07
D07 FT04
D07 FT04
TOILET MALE 03
Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
FT04 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE MODULAR CURTAIN WALL TO HAVE OPAQUE GLASS
CLIENT:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION
FT04 TOILET FLOOR TO BE WATERPROOFED AND SLOPED FOR DRAINAGE
ARCHITECT:
DYNAMIC ARCHITECTS A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL
1
Level 10 1 : 50
RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL
S A201
ROOM LEGEND 1. TOILET DISABLED 2. TOILET FEMALE 3. TOILET MALE 4. CORRIDOR 01 5. CORRIDOR 02 6. CORRIDOR 03 7. ROOFTOP GARDEN
TITLE:
ROOFTOP GARDEN PLAN
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
SCALE AT A1:
1:50 PROJECT NO:
DATE:
10
20
CHECKED:
DRAWN:
01.03.18 Author Checker DRAWING NO:
001 0
NO RT H
REVISION:
4
A111 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
Notes: HVAC UNIT HV01: JOHNSON CONTROLS SERIES 100 FORM 100.50‐EG10 (516) HV02: JOHNSON CONTROLS SERIES 40 355278‐JTG‐L‐0113 DOOR TYPES
A200 N
1
2
518
4600
510
B
3
A302
4600 6211
DT 01 SLIDING DOOR
4
5
4600
241 500
3927
6392
941
DT 03 DOUBLE DOOR
REFER TO A200 FOR CURTAIN WALL TYPE
DT 04 CURTAIN WALL (SINGLE) DT 05 CURTAIN WALL (DOUBLE)
WT02
WT07
WT02
DT 06 FIRE EXIT DOOR
WT07
3000
1300
585
535
3927
DT 02 SINGLE DOOR
500
CW
A
6
DT 07 TOILET DOOR
HVAC UNIT FOR WESTERN TOWER
HV01 2795
WALL TYPES
B
HV02
WT02
WT07
WT02
HV02
WT07
1818
WT02
WT07
WT07
WT02
WT07
2795
HV02
WT 05 (INTERIOR) 200mm CONCRETE WALL WT 06 (INTERIOR) 100mm TIMBER STUD
CW
REFER TO A200 FOR CURTAIN WALL TYPE
1300
WT02
SKY LIGHTS TO BE LIFTED FROMROOF. REFER TO ELEVATION
ROOFTOP GARDEN BELOW
1818
15635
1300
WT02
747
7807
WT03 (INTERIOR) 230 BLOCK VENEER
HV02
W
C
WT02 (EXTERIOR) 270mm BRICK VENEER
ROOFTOP GLASS PANELS TO BE WATERPROOFED
WT07 3636
HV01
A201
WT 01 (EXTERIOR) GLASS QUASI
WT 04 (INTERIOR) 300mm CONCRETE
747
1300
ROOFTOP GARDEN PLANTING TO REFER LANDSCAPE ARCHITECT'S PLAN
A A301
HV02
WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN
WT08 (INTERIOR) 200mm FEATURE WALL
FLOOR TYPES
E
A200 FT 01 150mm 6 CORE HC SLAB
STEEL BEAMS HOLDING THE SHADES CLOTHS UP
HV02
FT 02 300mm 4 CORE HC SLAB
HVAC UNIT FOR EASTERN TOWER HV02
FT 03 150mm GLASS FLOOR
HV02
1300
4193
FT 04 TOILET FLOOR
WT02
WT07
WT02
WT07
FT 05 CAFE FLOOR
STEEL PERGOLAR WITH SHADE CLOTHS
HV01 HV02
2795
D
FT 06 CLASSROOM FLOOR
HV02
5977
4
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV DESCRIPTION
PRELIMINARY
STATUS:
MODULAR CURTAIN WALL REFER TO FACADE DETAIL
DATE
1300
4127
DYNAMIC ARCHITECTS
WT02
WT07
Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
WT02 HV01
HV01 HV02 3317
HV02
CLIENT:
2347
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION
951
E
ARCHITECT:
DYNAMIC ARCHITECTS 6962
15710 TITLE:
ROOF PLAN
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
S A201
1
SCALE AT A1:
ROOF
1:50 PROJECT NO:
1 : 50
DATE:
10
20
CHECKED:
DRAWN:
01.03.18 Author Checker DRAWING NO:
001 0
NO RT H
REVISION:
4
A112 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
Notes: CEILING SCHEDULE CT01: [PLASTER PANELS] ULTIMA+OP BY 'ARMSTRONG' CT02: [TIMBER PANELS] LAUDER LINEA 4.2.1 BY 'LAUDESCHER' CT03: [TOILET CEILING] MINERAL FIBER PLANKS BY 'ARMSTRONG' CT04: [CAFE CEILING] INNOCEIL BY 'INNOWOOD' CT05: [EXPOSED FLOOR SLAB ABOVE] CT06: [CUSTOM TIMBER TRUSS] BY 'VERMONT TIMBER WORKS'
A200 N
1
2
500
4600
WT02
4
A302
4600
5
4600
3927
WT02
WT07
6
CW
3927
*CEILING PANELS INCORPORATE ACOUSTIC FOAM AS PER MANUFACTURERS' SPECIFICATIONS
941
LIGHT SCHEDULE LT01: [RECESSED LIGHT] 12w DL5530 316 LED DOWNLIGHT LT02: [PENDANT LIGHT] JET150 LED PENDANT LIGHT ‐BLACK CHROME LT03: [SCONCE LAMP] LUPE WALL SCONCE BY WEPLIGHT LT04: [WALL LAMP] BESTLITE BL7 WALL LAMP LT05: [TROFFER LIGHT] UNILUX PROFILE SURFACE MOUNT LT06: [LOUVER LIGHT] OFFICE PLUS LB LED P/T
REFER TO A200 FOR CURTAIN WALL TYPE
295
WT02
A
B
3
WT02
FIRE ESCAPE STAIRS 02
3000
LT02
LT02 LT04
WT07
600x1200mm TILED CEILING IN WORKSHOP TO HAVE PENDANT LIGHT HANGING FROM SLAB ABOVE
B
LT02
WT02
LT02
LT03
VOID ABOVE TO LVL 2
LOBBY 01
FT03
WT02
LT02
LT02
MAIN FEATURE STAIRS
A
7807
A301
LIFT SERVICE
LT02 WORKSHOP EXHIBITION
LT02
LT02
LT02 CW
LT02
REFER TO A200 FOR CURTAIN WALL TYPE
02 CT01
WT02
3650 mm
LT02 A201
LT02
LT02
W
LT02
LT02
LT03
LT02
C LT05
LT05
LT05
CT04
CAFE SERVICE
3950 mm
05
LT02
WT07
PENDANT LIGHTING TO BE PLACED BETWEEN TIMBER FEATURE CEILING PANELS
E
A200
75MMX350MM GLULAM CEILING BEAMS
LT02
LT02
CT02
4193
4000 mm
LT05 LT02
LT02
LT05
LT05 LT04
LT02
LT04
600x600mm CUSTOM MADE TIMBER PANELS WITH TROFFER LIGHTS IN CAVITY SPACE
CAFE KITCHEN LT02
LT05
06
CAFE COOL ROOM
D
CT01
07 LT02
LT02
LT02
LIFT 01
LIFT 02
3500 mm
LT04
3500 mm 4127
08
LT04
LT02
CT01 3650 mm
951
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18 DATE
PRELIMINARY
600x600mm TILED CEILING IN CAFE KITCHEN EQUPPED WITH TROFFER LIGHTS
DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
CT03
LT03
E
12/05/18
Mid Sem Presentation
STATUS:
LT04
REFUSE STORAGE
WT02
Final Package
3
REV DESCRIPTION
CT01
LT02
4
LT02
LT02
3500 mm
Disabled Toilet
FIRE ESCAPE STAIRS 01 SERVICE SHAFT [WORKSHOP]
04 TOILET UNISEX
SERVICE SHAFT [MAIN]
WT04
TOILET TO HAVE RECESSED CEILING WITH LIGHTS. REFER TO TYPICAL AMENITIES PLAN
CLIENT:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION
03 LT01
LT01
LT01
ARCHITECT:
DYNAMIC ARCHITECTS A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL
1
RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL
S
SERVICE SHAFT FOR OFFICE TOWER
WT04
A201
TITLE:
REFLECTED CEILING PLAN 01
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
SCALE AT A1:
GROUND FLOOR
1:50 PROJECT NO:
1 : 50
DATE:
10
20
CHECKED:
DRAWN:
01.03.18 Author Checker DRAWING NO:
001 0
NO RT H
REVISION:
4
A113 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
Notes: CEILING SCHEDULE CT01: [PLASTER PANELS] ULTIMA+OP BY 'ARMSTRONG' CT02: [TIMBER PANELS] LAUDER LINEA 4.2.1 BY 'LAUDESCHER' CT03: [TOILET CEILING] MINERAL FIBER PLANKS BY 'ARMSTRONG' CT04: [CAFE CEILING] INNOCEIL BY 'INNOWOOD' CT05: [EXPOSED FLOOR SLAB ABOVE] CT06: [CUSTOM TIMBER TRUSS] BY 'VERMONT TIMBER WORKS' CT07: [RAKED CEILING] TIMBER VENEER PANELS BY "INNOWOOD"
A200 N
1
2
500
B
3
4600
4600
3000
4
A302
5
4600
6000
6
3927
3927
*CEILING PANELS INCORPORATE ACOUSTIC FOAM AS PER MANUFACTURERS' SPECIFICATIONS
941
LIGHT SCHEDULE LT01: [RECESSED LIGHT] 12w DL5530 316 LED DOWNLIGHT LT02: [PENDANT LIGHT] JET150 LED PENDANT LIGHT ‐BLACK CHROME LT03: [SCONCE LAMP] LUPE WALL SCONCE BY WEPLIGHT LT04: [WALL LAMP] BESTLITE BL7 WALL LAMP LT05: [TROFFER LIGHT] UNILUX PROFILE SURFACE MOUNT LT06: [LOUVER LIGHT] OFFICE PLUS LB LED P/T
1200 815
WT02
REFER TO A200 FOR CURTAIN WALL TYPE
LT04 WT02
7900
1032
1170
295
575
CW
FIRE ESCAPE STAIRS 02
8638
LT04
3000
A
WT02
WT07
B
CONCEALED MACHINE ROOM FOR VERTICAL WIND TUNNEL
LT04 LT03
LT01
LT01
LT01
LT01
LT01
LT01
LT01
LT01
LT01
LT01
LT01
LT01
LT01
LT01
LT01
LT01
LT01
LT01
5875
3200
3050
WT07
LT04
950
CORRIDOR 02
300
05 FT03
3600
WT02
A
VERTICAL WIND TUNNEL TEST ROOM TO BE EXPOSED REFER TO DETAIL
MAIN FEATURE STAIRS
4000
7807
A301
LIFT SERVICE
MEETING ROOM 02
07
08
CONCEALED MACHINE ROOM FOR VERTICAL WIND TUNNEL
1332
LT01 CT07
LT01
LT04
LT01
LT01 CT07
LT01
4350 mm
4350 mm
400
7357
LT05
LT05
LT05
LT05
CORRIDOR 01 LT01
WORKSHOP
3000
LT05
06
LT05
LT05
LT05
LT05
CT02
04
LT01
LT05
LT05
4000 mm
LT05
LT05 MEETING ROOM 03
5000
4193
A200
LT03
VOID
WT07
7357
E
1778
C
LT01
09
LT01
LT01
LT01
WT02
LT01
CT05 4350 mm
LT01
LT01
LT01
2885
A201
W
3200
300
LT04
5139
MEETING ROOM 01
REFER TO A200 FOR CURTAIN WALL TYPE
CW
400
LT05
D
CT06
LIFT 02 LT05
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
LT05
PRELIMINARY DYNAMIC ARCHITECTS
LT05
Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
3000
WT07
DATE
LT05
LT05 3000
17/04/18
1300
LT05
3440
4000 mm
4000 mm
1664
FIRE ESCAPE STAIRS 01 SERVICE SHAFT [WORKSHOP]
RUBBISH CHUTE
WT02
SERVICE SHAFT [MAIN]
4000 mm
CT03
CT03
TOILET DISABLED
TOILET FEMALE
TOILET MALE
01
02
03
LT01
LT01
CT03
2500
4127
12/05/18
Mid Sem Presentation
STATUS:
4350 mm
951
Final Package
3
REV DESCRIPTION
LIFT 01
E
4
CLIENT:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:
LT01
DYNAMIC ARCHITECTS A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL
1
RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL
TITLE:
REFLECTED CEILING PLAN 02
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
S A201
SCALE AT A1:
Level 1
1:50 PROJECT NO:
1 : 50
DATE:
10
20
CHECKED:
DRAWN:
01.03.18 Author Checker DRAWING NO:
001 0
NO RT H
REVISION:
4
A114 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
Notes:
1
2
500
B
3
4600
CEILING SCHEDULE CT01: [PLASTER PANELS] ULTIMA+OP BY 'ARMSTRONG' CT02: [TIMBER PANELS] LAUDER LINEA 4.2.1 BY 'LAUDESCHER' CT03: [TOILET CEILING] MINERAL FIBER PLANKS BY 'ARMSTRONG' CT04: [CAFE CEILING] INNOCEIL BY 'INNOWOOD' CT05: [EXPOSED FLOOR SLAB ABOVE] CT06: [CUSTOM TIMBER TRUSS] BY 'VERMONT TIMBER WORKS'
4
A302
4600
5
4600
6
3927
3927
*CEILING PANELS INCORPORATE ACOUSTIC FOAM AS PER MANUFACTURERS' SPECIFICATIONS
941 LIGHT SCHEDULE LT01: [RECESSED LIGHT] 12w DL5530 316 LED DOWNLIGHT LT02: [PENDANT LIGHT] JET150 LED PENDANT LIGHT ‐BLACK CHROME LT03: [SCONCE LAMP] LUPE WALL SCONCE BY WEPLIGHT LT04: [WALL LAMP] BESTLITE BL7 WALL LAMP LT05: [TROFFER LIGHT] UNILUX PROFILE SURFACE MOUNT LT06: [LOUVER LIGHT] OFFICE PLUS LB LED P/T
6000
A
REFER TO A200 FOR CURTAIN WALL TYPE
295
CW
LT04 FIRE ESCAPE STAIRS 02
CORRIDOR 02
3000
05 LT04
D
LT01
LT01
LT01
LT01
LT01
LT01
FT03
LT01
5242
A305
LT01
600x1200mm TILED CEILING IN WORKSHOP TO HAVE PENDANT LIGHT HANGING FROM SLAB ABOVE
LT03
LT04
LT06
B
LT06
LT06
LT03 C A304
LT01
LT01
LT04 LT03
CLASSROOM 01
CT01
07
3600 mm
LT03 LT03
LT04
LT06
LT03
LT06
WALL LIGHT TO BE ATTACHED TO WT03 BLOCK VENEER
LT06
LT03 LT04 LT03 7807
A
LT01
A301
MAIN FEATURE STAIRS LT03
LT01
LIFT SERVICE
LT06
LT03 LT01
LT01
LT06
LT06
LT06
LT03
LT04
LT03 LT04
4350 mm
LT06
LT06
08
LT06
PENDANT LIGHT BETWEEN TIMBER TRUSS CEILING TO HANG FROM SLAB ABOVE
CT01
LT03 LT06
C
600x1200mm PANEL CEILING WITH RECESSED LIGHT IN CEILING CAVITY SPACE
CLASSROOM 02 LT06
CT06
LT06
LT03
5192
LT04
LT03
LT06
3600 mm
LT06
LT03 LT05
LT05
LT05 LT06
LT01
LT06
CORRIDOR 01
LT01
WORKSHOP
5242
3000
4193
04 LT05
LT05
06
CW
LT05
LT06
LT05
CT02
VOID ABOVE. WORKSHOP TO BE DOUBLE STORY HEIGHT
LT01
LT03
LT03
LT03
LT06 LT03
LT03
LT03
LT03
4000 mm
LT01
LT05
D
CT03
LT05
REFER TO A200 FOR CURTAIN WALL TYPE
VOID
600x600mm CUSTOM MADE TIMBER PANELS WITH TROFFER LIGHTS IN CAVITY SPACE
LT05 4000 mm
LIFT 01
4
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV DESCRIPTION
LIFT 02
PRELIMINARY
STATUS:
TOILET MALE LT05
LT05
LT05
FIRE ESCAPE STAIRS 01
951
Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
LT01
CT03
SERVICE SHAFT [WORKSHOP]
DYNAMIC ARCHITECTS
03
3000
3000
4127
3000
E
DATE
RUBBISH CHUTE
4000 mm
SERVICE SHAFT [MAIN]
TOILET DISABLED 01 LT01
CT03
TOILET FEMALE
4000 mm
02
TOILET TO HAVE RECESSED CEILING WITH LIGHTS. REFER TO TYPICAL AMENITIES PLAN
CLIENT:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:
LT01
DYNAMIC ARCHITECTS A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL
1
RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL
SERVICE SHAFT FOR OFFICE TOWER
TITLE:
REFLECTED CEILING PLAN 03
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
SCALE AT A1:
Level 3
1:50 PROJECT NO:
1 : 50
DATE:
10
20
CHECKED:
DRAWN:
01.03.18 Author Checker DRAWING NO:
001 0
NO RT H
REVISION:
4
A115 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
Notes: CEILING SCHEDULE CT01: [PLASTER PANELS] ULTIMA+OP BY 'ARMSTRONG' CT02: [TIMBER PANELS] LAUDER LINEA 4.2.1 BY 'LAUDESCHER' CT03: [TOILET CEILING] MINERAL FIBER PLANKS BY 'ARMSTRONG' CT04: [CAFE CEILING] INNOCEIL BY 'INNOWOOD' CT05: [EXPOSED FLOOR SLAB ABOVE] CT06: [CUSTOM TIMBER TRUSS] BY 'VERMONT TIMBER WORKS'
A200 N
1
2
500
4600
7
B
A403
A302
4600
4
5
4600
3927
WT02
WT07
6
CW
3927
*CEILING PANELS INCORPORATE ACOUSTIC FOAM AS PER MANUFACTURERS' SPECIFICATIONS LIGHT SCHEDULE LT01: [RECESSED LIGHT] 12w DL5530 316 LED DOWNLIGHT LT02: [PENDANT LIGHT] JET150 LED PENDANT LIGHT ‐BLACK CHROME LT03: [SCONCE LAMP] LUPE WALL SCONCE BY WEPLIGHT LT04: [WALL LAMP] BESTLITE BL7 WALL LAMP LT05: [TROFFER LIGHT] UNILUX PROFILE SURFACE MOUNT LT06: [LOUVER LIGHT] OFFICE PLUS LB LED P/T
941
REFER TO A200 FOR CURTAIN WALL TYPE
295
WT02
A
3
3000
WT02
FIRE ESCAPE STAIRS 02
LT02
LT02
LT02
LT02
LT02
D
WT07
A305
LT02
LT02
LT02
LT02
NO CEILING IN CORRIDOR 03. PENDANT LIGHT TO HANG FROM SLAB ABOVE
WT07
WT07 LT02
1
B
LT02
A402
SEMINAR ROOMS
C A304
LT02
08
LT02 LT02
CORRIDOR 02
CT05
05 WT07
WT05
NO CEILING IN MEETING ROOM. PENDANT LIGHT TO HANG FROM SLAB ABOVE
LT02
WT08
4350 mm
LT02
LT02
LT02
LT02
600x1200mm TILED CEILING IN WORKSHOP TO HAVE PENDANT LIGHT HANGING FROM SLAB ABOVE
LT02 8
7807
A
A403
LT02
A301
LIFT SERVICE
LT06
LT06
LT06
LT06
LT06
LT06
WT08 3 A402
CLASSROOM 04
VOID
CT05
LT02
3600 mm
LT06
4193
LT02 LT02
LT06
LT06
LT06
LT06
LT06
LT06
E
A200
LT02 LT02
WT07
LT06 CT01
06
C
LT06
LT02 CORRIDOR 03
3650 mm
W
07 LT06
4350 mm
CT03 A201
REFER TO A200 FOR CURTAIN WALL TYPE
LT02
LT02 WT02
CW
LT05
LT05
LT05
2
6
A402
A403
LT05
LT05
LT02
LT05
CT02
CORRIDOR 01
4000 mm
04
LT05
600x600mm CUSTOM MADE TIMBER PANELS WITH TROFFER LIGHTS IN CAVITY SPACE
WT08
LT02 WT02
LT05
D
TOILET MALE LT05
LT02
LIFT 01
LT02
LT05
03
4
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV DESCRIPTION
LIFT 02
DATE
PRELIMINARY
STATUS:
WT04 CT03
WT07
LT05
WT04
LT05
DYNAMIC ARCHITECTS
LT05
4127
4000 mm
Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
LT01
WT05 LT02
LT02
CT03
LT02 FIRE ESCAPE STAIRS 01
E
SERVICE SHAFT [WORKSHOP]
RUBBISH CHUTE WT05
WT02
4000 mm
SERVICE SHAFT [MAIN]
TOILET DISABLED
TOILET FEMALE
CT03
01
4000 mm
LT01
LT01
TOILET TO HAVE RECESSED CEILING WITH LIGHTS. REFER TO TYPICAL AMENITIES PLAN
CLIENT:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION
02
ARCHITECT:
DYNAMIC ARCHITECTS A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL
1
RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL
S
SERVICE SHAFT FOR OFFICE TOWER
WT04
A201
TITLE:
REFLECTED CEILING PLAN 04
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
SCALE AT A1:
Level 4
1:50 PROJECT NO:
1 : 50
DATE:
10
20
CHECKED:
DRAWN:
01.03.18 Author Checker DRAWING NO:
001 0
NO RT H
REVISION:
4
A116 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
E
1 : 100
4
3927
3
3927
4600
2 4600
ELEVATION EAST 1 : 100
E
1 4600
D 6342
500
1500
2595
B 1500 547 1500 547 1500
2595
A 1500 485
CW01 CURTAIN WALL MODULE TYPE1
ROOF
ROOF
49500
49500 CW02 CURTAIN WALL MODULE TYPE 2
3000
1300
WT02
C
2100
906
5
2100
6
CW08
CW05
CW01
WT02
CW01
CW10
Level 10
CW09
1500
CW01
7000
CW02
CW04
CW01
CW01
CW01
CW01
CW01
CW01
CW03 CURTAIN WALL MODULE TYPE 3
CW04 Level 10
45000
45000
CW01
CW03
CW04
CW03
CW01
2000
CW09
4500
WT07
CW06
CW05
CW01
CW04
CW01
CW08
CW09
CW03
CW01
CW04
CW01
CW01
CW05
CW03
CW04 CURTAIN WALL MODULE TYPE 4
CW10
Level 9
Level 9
40500
40500
CW01
CW02
CW11
CW04
CW03
CW01
CW01
CW01
CW01
CW02
CW05 CURTAIN WALL MODULE TYPE 5
CW06 CURTAIN WALL MODULE TYPE 6
CW04
7000
WT07
CW06
CW04
CW03
CW01
CW02
CW03
CW01
CW04
CW05
Level 8
Level 8
36000
36000
CW01
CW06
2000
CW07
CW09
CW03
CW03
CW01
CW01
CW01
CW01
CW01
CW08 CURTAIN WALL MODULE TYPE 8
Level 7
31500
31500
CW07
CW09
CW04
CW01
CW04
CW01
CW01
CW01
CW03
CW07 CURTAIN WALL MODULE TYPE 7
CW07
Level 7
CW01
CW09 CURTAIN WALL MODULE TYPE 9
CW01 CW10 CURTAIN WALL MODULE TYPE 10
7000
WT07 Level 6
Level 6
27000
27000 CW11 CURTAIN WALL MODULE TYPE 11
CW08
CW01
CW03
CW04
CW01
CW01
CW02
CW11
CW03
CW01
CW01
CW01
CW01
CW01
CW01
CW06 REFER TO DRAWING A600 FOR ASSEMBLY AND PANEL INSERT TYPE
2000
WT02
CW01
CW08
CW04
CW03
CW01
Level 5
Level 5
22500
22500
CW01
CW08
CW09
CW04
CW09
CW03
CW01
CW01
CW05
CW01
ANY GLAZED PANELS THAT FALL ON AND BETWEEN GRIDS E AND D BACK COATED IN SOLID SILK SCREEN
CW02
7000
WT07
CW07
CW04
CW03
CW04
CW01
Level 4
Level 4
18000
18000
CW01
CW06
CW11
CW04
CW01
CW04
CW01
CW01
CW01
CW10
CW03
4
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV DESCRIPTION
2000
CW08
CW06
CW08
CW03
CW01
Level 3
Level 3
13500
13500
CW01
CW09
CW11
CW01
CW03
CW04
CW01
CW01
CW01
CW01
DATE
PRELIMINARY
STATUS:
DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
CW04
7000
WT07 Level 2
Level 2
9000
9000
CLIENT:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:
CW05
CW01
CW03
CW01
CW02
CW05
CW01
CW01
WT07
CW05
CW01
CW01
CW01
CW01
CW01
CW04
CW11
DYNAMIC ARCHITECTS
Level 1
Level 1
4500
2500
CW04
WT01
CW02
D03 GROUND FLOOR 0
CW09
CW04
CW03
CW04
CW01
CW01
CW01
890 890 890 890 940
CW03
1000 1000
CW02
1000
N
ELEVATION NORTH
Notes:
TITLE:
ELEVATIONS ‐ NORTH & EAST
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
4500
SCALE AT A1:
1:100 PROJECT NO:
GROUND FLOOR
DATE:
01.03.18 D.K & J.V DRAWING NO:
001
0 0
10
20
CHECKED:
DRAWN:
E.B REVISION:
4
A200 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
W
1 : 100
2000
6944
WT02
3 400
4
6592
HV01
5 8718
HV02
A
6
B
485 1500
406
HV01 ROOF
Notes:
1 : 100
2100
2
ELEVATION WEST 2595
C 1500 547 1500 547 1500
HV01
HV02
HV01
2595
D 1500
6342
HV01
HV02 HV02
E
HV01 ROOF
69
1
49500
49500 4034
Level 10
CW08
Level 9 40500
WT07
WT07
WT07
WT07
WT07
45000
WT07
WT07
WT07
Level 9 40500
3500
CW02
WT07
Level 10
2600
45000
WT02
901 397
CW10
1000 1000
4600
WT02
WT07
WT07
WT07 Level 8
36000
36000 3500
Level 8
CW06
31500
31500
3500
CW07
Level 7
2000
Level 7
WT07
WT07
WT07
Level 6
Level 6
27000
27000 3500
WT04
CW02 WT02 Level 5 22500
22500
3500
CW08
Level 5
2000
45000
WT07
WT07
WT07 Level 4
18000
18000 3500
Level 4
CW06
4
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV DESCRIPTION
13500
DATE
PRELIMINARY
STATUS:
1000 1000
Level 3
Level 3 13500
DYNAMIC ARCHITECTS
3
Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
A400
CW09 WT07
9000
WT07
WT07 Level 2
7000
Level 2
CLIENT:
9000
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION
CW02
ARCHITECT:
2650
4500
CW02
GROUND FLOOR 0
DYNAMIC ARCHITECTS
850 1000
Level 1
1000
S
ELEVATION SOUTH
Level 1 4500
WT07
TITLE:
ELEVATIONS ‐ SOUTH & WEST
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
WT07 D06
SCALE AT A1:
1:100
GROUND FLOOR
PROJECT NO:
0
DATE:
01.03.18 Author Checker DRAWING NO:
001 0
10
20
CHECKED:
DRAWN:
REVISION:
4
A201 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
SERVICE ZONE TRANSPARENT ZONE
-4000
BASEMENT
0
GROUND FLOOR
Level 1
4500
EXHIBITION ROOM
VERTICAL WIND TUNNEL 9000
Level 2
13500
Level 3
18000
Level 4
VOID AREA
HANGING BOX 22500
Level 5
27000
Level 6
SERVICE LIFT
MAIN FEATURE STAIRS 31500
Level 7
WORKSHOP DOUBLE HEIGHT 36000
Level 8
40500
Level 9
45000
Level 10
49500
ROOF
1
LOUNGE ZONE
2 3
OFFICE ZONE
4
CLASSROOM ZONE
5 0
10
20
30
Notes:
40
4
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV
STATUS:
50
60
70
80
90
100
DESCRIPTION
PRELIMINARY
DATE
DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
CLIENT:
SITE:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:
DYNAMIC ARCHITECTS
TITLE:
WORKSHOP ZONE
1 : 100
1
ZONE SECTION
BASEMENT WORKSHOP
CAFE
MEETING ROOM
LECTURE ROOM
CLASSROOM
OFFICE
STUDENT LOUNGE
ROOFTOP GARDEN
6 ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS.CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
81/89 BOUVERIE ST, CARLTON VIC 3053
SCALE AT A1:
ZONE SECTIONS
PROJECT NO:
1 : 100 001
DATE:
DRAWN:
CHECKED:
01.03.18 Author
Checker
DRAWING NO:
REVISION:
A300
4
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS.CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
0 10 20 30
Notes:
40 50 60 70 80 90 100 4 Final Package 12/05/18
3 Mid Sem Presentation 17/04/18
2 Preliminary Design 22/03/18
REV
1 Project Set Up
STATUS: DESCRIPTION
03/03/18
PRELIMINARY DATE
DYNAMIC ARCHITECTS
Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au CLIENT:
ARCHITECT:
DYNAMIC ARCHITECTS SITE:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION TITLE:
81/89 BOUVERIE ST, CARLTON VIC 3053 SCALE AT A1:
SECTION A PROJECT NO:
1 : 100 001
DATE:
A301
DRAWN:
CHECKED:
01.03.18 Author Checker
DRAWING NO: REVISION:
4
A
1 : 100
SECTION A
FT02 300mm HOLOCORE CONCRETE FLOOR TO SIT ON CONCRETE FOOTING.
WT04 300mm CONCRETE FLOOR AROUND THE BASEMENT BOUNDARY. REFER TO PLAN
LOBBY & CAFE ON GROUNDFLOOR. REFER TO PLAN
MEETING ROOM. REFER TO PLAN
LECTURE ROOM. REFER TO PLAN
CLASSROOM 02. REFER TO PLAN
FT02 150mm CONCRETE SLAB
CLASSROOM 04. REFER TO PLAN
CLASSROOM 06. REFER TO PLAN
LIFT 01 & LIFT 02. REFER TO PLAN
OFFICE ROOM. REFER TO PLAN
PHD RESEARCH ROOM. REFER TO PLAN
MAIN FEATURE STAIRS. REFER TO DETAILS
MALE, FEMALE, DISABLED TOILETS. REFER TO PLAN
STUDENT LOUNGE. REFER TO PLAN
STUDENT LOUNGE. REFER TO PLAN
FT03 GLASS FLOOR TO BE SUPPORTED BY STEEL BEAMS ATTACHED TO COLUMNS AND FLOOR SLAB
STEEL BEAM BETWEEN COLUMNS
ROOFTOP GARDEN. REFER TO PLAN
CW TO BE 1.5m TALL ON LEVEL 10
STEEL PEGOLAR WITH SHADE CLOTHS.
CW01
CW01
CW01
A600
2
CW01
CW01
CW01
CW01
CW01
CW01
CW01
CW09
6
5
4 WT07
3
2
1
4500
Level 1
9000
Level 2
13500
Level 3
18000
Level 4
22500
Level 5
-4000
BASEMENT
0
GROUND FLOOR
WT02
27000
Level 6
31500
Level 7
36000
Level 8
40500
Level 9
45000
Level 10
49500
ROOF
CONCRETE PILE
CONCRETE STRIP FOOTING
WORKSHOP BASEMENT
BASEMENT LOBBY
EXHIBITION ROOM
WT 02 BRICK VENEER
VERTICAL WIND TUNNEL
WORKSHOP 01
WIND TUNNEL MACHINE ZONE
WORKSHOP 02
TIMBER TRUSS FRAME
HANGING BOX
WORKSHOP 03
LIFT SERVICE
WT 03 BLOCK VENEER
WORKSHOP 04
WT 07 CURTAIN WALL
STEEL BEAM
WORKSHOP 05
STEEL BEAM RAFTERS CONNECTED TO CELLULAR STEEL BEAM
HVAC PLANTS ON ROOF
SKY LIGHT
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS.CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
0 10 20 30
Notes:
40 50 60 70 80 90 100 4 Final Package 12/05/18
3 Mid Sem Presentation 17/04/18
2 Preliminary Design 22/03/18
REV
1 Project Set Up
STATUS: DESCRIPTION
03/03/18
PRELIMINARY DATE
DYNAMIC ARCHITECTS
Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au CLIENT:
ARCHITECT:
DYNAMIC ARCHITECTS SITE:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION TITLE:
81/89 BOUVERIE ST, CARLTON VIC 3053 SCALE AT A1:
SECTION B PROJECT NO:
1 : 100 001
DATE:
A302
DRAWN:
CHECKED:
01.03.18 Author Checker
DRAWING NO: REVISION:
4
B
CW01
CW03
CW03
CW04
CW03
CW01
CW05
CW03
CW04
CW04
CW01
1 : 100
SECTION B
BASEMENT WORKSHOP. REFER TO PLAN
DT01 MAIN ENTRANCE
LOBBY & CAFE. REFER TO PLAN
ALL EXPOSED STEEL STRUCTURES TO BE FIREPROOFED WITH PAINTING
LECTURE ROOM FLOOR.
FEATURE STAIRS & WIRE BALUSTRADE. REFER TO DETAIL
STEEL I BEAM TO SUPPORT FT03 GLASS FLOOR. REFER TO DETAIL
400x400mm CONCRETE COLUMN
DT04 SINGLE DOOR ON CURTAIN WALL TO BE 2.5m TALL
WT01 MODULAR CURTAIN PANEL. REFER TO DETAIL
DT05 DOUBLE DOOR ON CURTAIN WALL TO BE 2.5m TALL
DT04 SINGLE DOOR ON CURTAIN WALL TO BE 2.5m TALL
WT08 200mm TIMBER CLADDED WALL
PHD RESERACH ROOM KITCHEN. REFER TO PLAN
WT03 230mm BLOCK VENEER WALL
DT01 TO BE 3m TALL
WT07 CURTAIN WALL BETWEEN WT03 VLOCK VENEER WALL
MAIN FEATURE STAIRS ON LVL8-10 TO BE REVERSED. REFER TO PLAN FOR DETAIL
DT01 AUTOMATIC SLIDING DOORS
SKY LIGHTS TO HAVE WINOW PANELS ON BOTH ENDS
WT07
A
B
WT07
A
WT07
A301
WT07
C
WT07
D
E
WT04
-4000
BASEMENT
0
GROUND FLOOR
4500
Level 1
9000
Level 2
13500
Level 3
18000
Level 4
22500
Level 5
27000
Level 6
31500
Level 7
36000
Level 8
40500
Level 9
45000
Level 10
49500
ROOF
CONCRETE PILE
CONCRETE STRIP FOOTING
DT03 TO BIKE ROOM
CEILING ZONE
WT08 200mm TIMBER CLADDED WALL FOR CAFE KITCHEN
TIMBER FEATURE CEILING. REFER TO RCP
WT07 CURTAIN WALL FOR MEETING ROOMS
DT01 TO BE 3m TALL
WT06 100mm TMBER STUD WALL
400x400mm CONCRETE COLUMN
STEEL BEAM BETWEEN COLUMNS ATTACHING STAIRS AS WELL
STEEL BEAM BETWEEN COLUMNS ATTACHING STAIRS AS WELL
DT03 DOUBLE DOOR
FIRE ESCALE 01. REFER TO PLAN
WT04 & WT05 CONCRETE WALL. REFER TO PLAN
STUDENT LOUNGE AREA. REFER TO PLAN
STEEL BEAM BETWEEN COLUMNS TO BE FIREPROOFED WITH PAINTING
LIFT 01 & 02. REFER TO PLAN
HVAC UNIT ON ROOF
ROOF PLANTS TO BE POSITIONED FOR ACCESSABILITY BETWEN UNITS
B
4
3
A302
2
1
LT03 CEILING ZONE
STEEL BEAM BETWEEN COLUMNS PENDANT LIGHT TO ATTACH TO FLOOR ABOVE
LT02
LT02 50mm TILE CEILING
SCONCE LAMP TO ATTACH TO COLUMN
WT04 300mm CONCRETE WALL
SEMINAR ROOMS
MAIN FEATURE STAIRS
08
CORRIDOR 02
CORRIDOR 03
05
06
FIRE ESCAPE STAIRS 02
PENDANT LIGHT TO ATTACH TO FLOOR ABOVE
WT07 LT03
LT03
VERTICAL STEEL WIRE TO BE ATTACHED TO FLOOR BELOW AND ABOVE SUPPORTING THE HANING BOX
LT03 WT07 CURTAIN WALL WITH 150x50mm ALUMINIUM MULLION
DIAGRONAL STEEL WIRE TO BE ATTACHED TO FLOOR BELOW AND ABOVE SUPPORTING THE HANING BOX
WT02 VOID
FURTNITURES TO FACE WORKSHOP
Level 4 FT03
FT06
18000
FT01
FT01 150mm HOLLOW CORE CONCRETE FLOOR
WT05 1 FEATURE TIMBER TRUSS CEILING
LT01
LT03 FT03 GLASS FLOOR. REFER TO DETAIL
LT03
LT01 PENDANT LIGHTS TO BE PLACED BETWEEN TIMBER TRUSS HANGING FROM FT01
LT04
07 LT03
FIRE ESCAPE STAIRS
400x400mm CONCRETE COLUMN FEATURE WALL LIGHT. REFER TO MANUFACTURE'S DETAIL
MAIN FEATURE STAIRS WITH WIRE BALUSTRADE. REFER TO DETAIL
MAIN FEATURE STAIRS
WT07
WT03
STEEL BEAM TO SUPPORT GLASS FLOOR TO BE ATTACHED TO COLUMN
CLASSROOM 01
A400
CORRIDOR 02
WT03 BLOCK VENEER WITH WT07 CURTAIN WALL IN BETWEEN. REFER TO DETAIL
05
CURTAIN WALL BETWEEN BRICK VENEER. REFER TO DETAIL
WORKSHOP 06
WT02 BRICK VENEER. REFER TO DETAIL
STEEL BEAMS SUPPORTING GLASS TO BE WELDED TOGETHER IN SHOP BEFORE INSTALLMENT. REFER TO DETAIL
WT07 LT03 STEEL BEAM WITHIN CEILING ZONE
FT02 300mm CONCRETE SLAB
WT03
Level 3 FT03
FT06
13500
FT01 FT02
C
Section 1 1 : 20
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS.CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
0
10
20
30
Notes:
40
4
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV
STATUS:
50
60
70
80
90
100
DESCRIPTION
PRELIMINARY
DATE
DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
CLIENT:
SITE:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:
DYNAMIC ARCHITECTS
TITLE:
81/89 BOUVERIE ST, CARLTON VIC 3053
SCALE AT A1:
SECTION C
PROJECT NO:
1 : 20 001
DATE:
DRAWN:
CHECKED:
01.03.18 Author
Checker
DRAWING NO:
REVISION:
A304
4
6
5
4
6
2
7
A403
A402
A403
3
CW01 Level 5 FT06
FT03
22500
FT02 REFER TO DETAIL FOR GLASS FLOOR
LT03
LT02
LT02
STEEL BEAM BETWEEN COLUMNS TO BE EXPOSED AND FIRERATED WITH INTUMESCENT PAINT
LT02
LT02
STEEL BEAM BETWEEN COLUMNS TO BE EXPOSED AND FIRERATED WITH INTUMESCENT PAINT
PENDANT LIGHT TO ATTACH INTO FT02 ABOVE
LT03 SCONCE LIGHT TO ATTACH INTO WT08
MAIN FEATURE STAIR TO BE FOLDED STEEL ATTACHED TO FLOOR SLAB AND SUPPORTED WITH TENSION WIRE. REFER TO DETAIL
CW01 SEMINAR ROOMS LT03
08
LT03
WT07
CORRIDOR 02 05
LT03
WT07
CORRIDOR 03 06
WT07 LT03
LT03
LT03 TENSION WIRE TO ATTACH ONTO BEAM AND FLOOR SLAB ABOVE
Level 4 FT03
FT06
18000
FT01 T BEAM AND I BEAM TO BE WELDED TOGETHER PRIOR TO INSTALATION
TENSION WIRE TO DIVIDE BETWEEN LEVELS AND ATTACHED INTO I BEAM
LT03 LT06
LT01
LT06
LT01
LT01
I BEAM TO SUPPORT FT03 AND ATTACHED ONTO COLUMN. REFER TO DETAIL
LT01
LT01
LT06
LT01
LT01
WALL LAMP TO ATTACH ONTO WT03 REFER TO RCP
LT01
LT03
PENDANT LIGHT TO ATTACH INTO FT02 ABOVE
WT03
LT04 TIMBER TRUSS AS FEATURE CEILING.
WT08 400x400mm CONCRETE COLUMN
STEEL BEAM BETWEEN COLUMNS AND FIRERATED
RECESSED LIGHTS TO BE ATTACHED INTO CEILING ZONE
LT03 CW03
CW10
PENDANT LIGHT TO HANG FROM CEILING
50mm CEILING UNDER BEAM LEVEL
FT02 300mm HOLOCORE CONCRETE
SCONCE LIGHT TO ATTACH INTO WT08
CLASSROOM 01
CORRIDOR 02
07 PROPRIETRAY FURNITURES TO CLASSROOMS. REFER TO MANUFACTUER'S DETAIL
LT03
LT03
FT01 150mm HOLLOWCORE CONCRETE. REFER TO DETAIL
WORKSHOP D01
05
06 WORKSHOP TO BE EQUIPED WITH SPECIFIC MACHINERY. REFER TO FACULTY OFFICE
TENSION WIRE TO BE INSTALLED 120mm APART THAT SUPPORT STAIRS AND HAND RAILS. REFER TO DETAIL
D03
FT01 TO SAWTOOTH ATTACHING TO WT01. REFER TO DETAILS HANDRAILS TO COMPLY BCA AND AS1170.1
Level 3 FT06
FT03
13500
FT02
CW04
D
Section 2 1 : 20
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS.CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
0
10
20
B A302
30
Notes:
40
4
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV
STATUS:
50
60
70
80
90
100
DESCRIPTION
PRELIMINARY
DATE
DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
CLIENT:
SITE:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:
DYNAMIC ARCHITECTS
TITLE:
81/89 BOUVERIE ST, CARLTON VIC 3053
SCALE AT A1:
SECTION D
PROJECT NO:
1 : 20 001
DATE:
DRAWN:
CHECKED:
01.03.18 Author
Checker
DRAWING NO:
REVISION:
A305
4
Notes: 1
A
B
R‐VALUE CALCULATION FOR WT02 BRICK VENEER EXTERIROR WALL
5010050
1
BRICK VENEER 10mm MOTAR GAP
BRICK VENEER: 40mm AIR GAP: KINGSPAN Kooltherm K18 Insulated Plasterboard:
0.50 0.3 2.0
TOTAL R‐VALUE:
2.8
BRACE FASTENING BRICKS ATTACHED TO STEEL BEAM
BRICK VENEER
FIREESCAPE STAIRS 02 REFER TO PLAN FOR DETAIL
100x100mm STEEL BEAM ATTACHING BRACE
STEEL BRACE WITH WEEPED SCREED
900
BRICK VENEER 40mm AIR GAP
50x50mm TIMBER SUB STRUCTURE TO ATTACH INSULATION AND PLYWOOD SUBSTRATE
CW01
1170
WATER PROOF MEMBRANE
SEALANT
WT02 40mm RIGID INSULATION 10mm PLYWOOD SUBSTRATE
BRICK VENEER
PLASTER BOARD
WATERPROOF MEMBRANE
50x50mm TIMBER BLOCK FIXING UNIT
40mm AIR GAP
WATERPROOF MEMBRANE BETWEEN MULLION AND STEEL BEAM
40mm RIGID INSULATION BRICK VENEER ZONE
10mm PLYWOOD SUBSTRATE PLASTERBOARD TO ATTACHED ONTO SUBSTRATE
WT07
150
150mm CONCRETE FLOOR REFER TO PLAN FOR DETAIL ANCHOR BOLTS WITH TIEBACKS ATTACHED TO FLOOR
6mm LOW E INSULATING TEMPERED GLASS
Level 4
BRICK VENEER ZONE
LOW E DOUBLE GLAZED CURTAIN WALL
Level 4
6900
150x80mm STEEL MULLION
18000
18000 150x50mm STEEL MULLION. REFER TO DETAIL
LOW E DOUBLE GLAZED CURTAIN WALL
100x100 STEEL BEAM ATTACHED TO FLOOR
12mm ARGON GAS 50
150x60mm STEEL MULLION TO BE SEALED FOR WATERPROOFING
100x100mm STEEL BEAM WELDED TOGETHER
6mm LOW E INSULATING TEMPERED GLASS
U-MAX THERMAL BREAK 150x60mm FRONT DOUBLED GLAZED WINDOW C A304
250
4350
CW01 MODULAR CURTAIN WALL REFER TO FACADE DETAIL
50x50mm TIMBER BLOCK TO SIT BETWEEN INSULATION AND PLYWOOD
WT02
950
WATER TO FALL THROUGH WEEPING HOLE
5010050
270
WT02
STEEL BRACE WITH WEEPED SCREED
BRICK VENEER ZONE
BRICK VENEER
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
DYNAMIC ARCHITECTS
Level 3
1700
BRICK VENEER
DATE
PRELIMINARY
STATUS:
BRICK VENEER ZONE
BRICK VENEER ZONE
40mm AIR GAP
WT04
4
REV DESCRIPTION
SEALANT
Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
13500
WATERPROOF MEMBRANE
40mm AIR GAP 40mm RIGID INSULATION CLIENT:
10mm PLYWOOD SUBSTRATE
PLASTERBOARD TO ATTACHED ONTO SUBSTRATE
WATERPROOF MEMBRANE
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION
5010050
ANCHOR BOLTS WITH TIEBACK ATTACHED TO WALL
300
ARCHITECT:
150
A
100x100 STEEL BEAM ATTACHED TO FLOOR
Level 3
ANCHOR BOLTS WITH TIEBACKS ATTACHED TO FLOOR
13500
DYNAMIC ARCHITECTS LOW E DOUBLE GLAZED CURTAIN WALL
BRICK VENEER ZONE
10050
760
5010050
BRICK VENEER ZONE
2950
TITLE:
TYPICAL FACADE 01
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
5010050
SCALE AT A1:
2
FACADE DETAIL PLAN 1 : 10
1
FACADE DETAIL SECTION 1 : 10
3
N/A
FACADE DEATIL ELEVATION
PROJECT NO:
DATE:
01.03.18 Author Checker DRAWING NO:
001
1 : 20 0
10
20
CHECKED:
DRAWN:
REVISION:
4
A400 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
BENT STEEL PLATE CAPPED AT FFL
SEALANT W BACKING ROD 10MM THICK STEEL PLATE SPACER BOLTED TO FLOOR PLATE
FIRESTOP WITH SMOKE SEAL
6MM LAMINATED IGU GLASS
CURTAIN WALL STACK JOINT SYSTEM ANCHORED TO CONCRETE SLAB
BENT STEEL PLATE CAPPED AT FFL FIRESTOP WITH SMOKE SEAL FLOOR FINISH - VINYL 40MM SUB-FLOOR INSULATION FFL
6MM LAMINATED IGU GLASS
6MM LAMINATED IGU GLASS
BENT STEEL PLATE CAPPED AT FFL
STEEL ANCHOR PLATE
IGU SPACER BAR WEATHER SEALANT CUSTOM MULLIPON CASING SET IN STRUCTURAL FACADE FRAMING
IGU SPACER BAR WEATHER SEALANT
FIRESTOP WITH SMOKE SEAL
FLOOR FINISH - VINYL
IGU SPACER BAR WEATHER SEALANT
FLOOR FINISH - VINYL 40MM SUBFLOOR INSULATION
SEALANT W BACKING ROD 40MM SUB-FLOOR INSULATION
FFL
CUSTOM MULLIPON CASING SET IN STRUCTURAL FACADE FRAMING
CUSTOM MULLIPON CASING SET IN STRUCTURAL FACADE FRAMING
FFL
STRUCTURAL SEALANT RFL
RFL
STRUCTURAL SEALANT
RFL
STRUCTURAL SEALANT
5MM THICK, 70MM DIAMETER STEEL DIAGONAL SUPPORT HORIZONTAL TUBE. SUNSHADE MESH PANEL INDERTED INTO TUBE SUNSHADE MESH PANEL INSERT
5MM THICK, 70MM DIAMETER STEEL HORIZONTAL TUBE. FACADE PANEL STRUCTURAL SUPPORT 5MM THICK, 70MM DIAMETER STEEL HORIZONTAL TUBE. FACADE PANEL STRUCTURAL SUPPORT
5MM THICK, 70MM DIAMETER STEEL DIAGONAL SUPPORT HORIZONTAL TUBE.
HOLLOW CORE COCRETE SLAB HOLLOW CORE COCRETE SLAB
CELLULAR BEAM LB460x30
LOWER STRUCTURAL STEEL FACADE FRAMING
300 MM HOLLOW CORE COCRETE SLABSAW TOOTH PLAN TO ACCOMODATE DIAGONAL FACADE PANEL
INSULATED ALUMIUM COMPOSITE PANEL REFER TO A600 FOR ASSEMBLY CELLULAR BEAM LB460X30
INSULATED ALUMINIUM COMPOSITE PANEL. REFER TO A600 FOR ASSEMBLY
SUSPENSION WIRE BOLETED TO FLOOR SLAB
SUSPENSION WIRE BOLETED TO FLOOR SLAB
CEILING EDGE CAP
CEILING EDGE CAP
CEILING EDGE CAP SUSPENDED CELING PANEL
SUSPENDED CEILING PANEL
SEALANT W BACKING ROD
SUSPENDED CEILING PANEL
BENT STEEL PLATE CAPPED AT FFL FIRESTOP WITH SMOKE SEAL
10MM THICK STEEL PLATE SPACER BOLTED TO FLOOR PLATE BENT STEEL PLATE CAPPED AT FFL 3
FIRESTOP WITH SMOKE SEAL
A401
FLOOR FINISH - VINYL 40MM SUB-FLOOR INSULATION FFL
6MM LAMINATED IGU GLASS
INSULATED ALUMIUM COMPOSITE PANEL REFER TO A600 FOR ASSEMBLY
BENT STEEL PLATE CAPPED AT FFL
IGU SPACER BAR WEATHER SEALANT
STEEL ANCHOR PLATE
IGU SPACER BAR WEATHER SEALANT
6MM LAMINATED IGU GLASS
INSULATED ALUMINIUM COMPOSITE PANEL. REFER TO A600 FOR ASSEMBLY
CURTAIN WALL STACK JOINT SYSTEM ANCHORED TO CONCRETE SLAB
FIRESTOP WITH SMOKE SEAL SEALANT W BACKING ROD
40MM SUBFLOOR INSULATION
CUSTOM MULLIPON CASING SET IN STRUCTURAL FACADE FRAMING
CUSTOM MULLIPON CASING SET IN STRUCTURAL FACADE FRAMING
FFL
STRUCTURAL SEALANT
STRUCTURAL SEALANT
RFL
RFL
IGU SPACER BAR WEATHER SEALANT
FLOOR FINISH - VINYL
FLOOR FINISH - VINYL
40MM SUB-FLOOR INSULATION
CUSTOM MULLIPON CASING SET IN STRUCTURAL FACADE FRAMING
FFL
RFL
STRUCTURAL SEALANT
5MM THICK, 70MM DIAMETER STEEL DIAGONAL SUPPORT HORIZONTAL TUBE. SUNSHADE MESH PANEL INDERTED INTO TUBE SUNSHADE MESH PANEL INSERT
D A304
LOWER STRUCTURAL FACADE FRAMING 5MM THICK, 70MM DIAMETER STEEL HORIZONTAL TUBE. FACADE PANEL STRUCTURAL SUPPORT
5MM THICK, 70MM DIAMETER STEEL HORIZONTAL TUBE. FACADE PANEL STRUCTURAL SUPPORT
5MM THICK, 70MM DIAMETER STEEL DIAGONAL SUPPORT HORIZONTAL TUBE.
5
HOLLOW CORE COCRETE SLAB
A401
6LAMINATED IGU GLASS
lEVEL 1 CONCRETE SLAB
CONCRETE BEAM LB460x30
2
FACADE PLAN DETAIL 1 : 10
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS.CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
0
10
20
30
Notes:
40
Sample Notes
3
INSULATED ALUMIUM COMPOSITE PANEL REFER TO A600 FOR ASSEMBLY
FACADE SECTION DETAIL 1
4
1:5
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
70
80
90
100
DESCRIPTION
PRELIMINARY
5
1:5
Final Package
STATUS:
60
FACADE SECTION DETAIL 2
4
REV
50
300 MM HOLLOW CORE COCRETE SLABSAW TOOTH PLAN TO ACCOMODATE DIAGONAL FACADE PANEL
DATE
DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
CLIENT:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:
DYNAMIC ARCHITECTS
FACADE SECTION DEATIL 3 1:5
SCALE AT A1:
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053 TITLE:
DETAILS 03 GLASS FACADE
DATE:
DRAWN:
As 01.03.18 Author indicated
PROJECT NO:
001
DRAWING NO:
A401
CHECKED:
Checker REVISION:
4
A
B
C
WELDED STEEL BRACKET TO BE INSERTED INTO CONCRETE SLAB
400x470mm CONCRETE COLUMN
3
WELDED STEEL BRACKET TO BE INSERTED INTO COLUMN
10800
A402
•
400x400mm CONCRETE COLUMN
SILICON SEALENT LAMI COMPATIBLE
WT02 BRICK VENEER WALL
3
WELDED STEEL BRACKET TO ATTACH INTO COLUMN
3000
3000 2000
PANAL A
PANAL B
PANAL B
30mm COVER PANEL MADE OF SGS GLASS
T BRACKET DIVIDING GLASS PANELS
WT01 MODULAR GLASS WALL
• •
STEEL I BEAM TO CONNECT TO CONCRETE COLUMN VIA CAST IN CONCRETE BRACKET
AIR GAP
FT03 FRAMES TO BE CONSTRUCTED AT SHOP THEN DELIVERED TO SITE FOR FITTING ALL WELDED FRAMES TO BE GRIDED IN SHOP ALL EXPOSED METAL TO BE FIRERATED BY USING INTUMESCENT PAINT STEEL BRACKET TO CAST INTO CONCRETE COLUMN FT03 GLASS FLOOR PANELS TO CUT AND FIT TO LAY WITHIN THE STEEL FRAMES. REFER TO MANUFACTURE'S DETAIL STEEL BRACKETS ON CONCRETE COLUMNS TO BE INSTALLED DURING COLUMN CONSTRUCTION
• •
WELDED STEEL BRACKET TO ATTACH INTO COLUMN
SILICON PROFILE 60-70 SHORE
TRIPLE LAYERED TEMPERED GLASS FLOOR
WORKSHOP ENTRANCE 3000
Notes:
4
2
•
FT 01 150mm CONCRETE FLOOR
50mm SGS GLASS 50mm SGS GLASS
PANAL B
Level 5 2
A402
22500
VOID 1850
PANAL C
TRIPLE LAYERED GLASS FLOOR STEEL I BEAM SUPPORTING GLASS FLOOR TO CONNECT VIA CAST IN CONCRETE
WELDED STEEL BRACKET ATTACHED TO CONCRETE SLAB
4
T BRACKET TO BE WELDED TOGETHER IN SHOP BEFORE INSTALLATION
4 A402
FT02 300mm CONCRETE FLOOR
D
A305
1
I BEAM UNDER TO SUPPORT WELDED STEEL BRACKET
A402
3
A402
WELDED STEEL BRACKET ATTACHED TO CONCRETE SLAB
1
SECTION 01 MAIN STAIRS. REFER TO STAIRS DETAIL
1 : 20 2 A402
TESNTION WIRE TO BE ATTACHED TO I BEAM
4 SILICON SEALENT LAMI COMPATIBLE
30mm COVER PANEL MADE OF SGS GLASS
SILICON PROFILE 60-70 SHORE
50mm SGS GLASS
3
BALUSTRADE TO BE ATTACHED TO TENSION WIRE HAND RAIL TO BE ATTACHED TO TENSIONWIRE WITH CLAMP
50mm SGS GLASS
WT03 BLOCK VENEER WALL AND WT07 CURTAIN WALL. REFER TO WALL DETAIL 30mm COVER PANEL MADE OF SGS GLASS
50mm SGS GLASS 50mm SGS GLASS STEEL BRACKET TO ATTACH INTO FLOOR SLAB AND COLUMN
TENSION WIRE
Level 5 T BRACKET AND I BEAM TO BE WELDED TOGETHER IN SHOP BOFORE INSTALLATION
BRACKETS WELDED TOGETHER IN SHOP BEFORE INSTALLATION
22500
I BEAM TO CONNECT INTO COLUMN TO ENFORCE STRENGTH
TENSION WIRE TO CONNECT INTO I BEAM
I BEAM TO BE INSERTED INTO COLUMN AND FLOOR TO BE INSATLLED FIRST
I BEAM SUPPORTING BRACKET TO BE WELDED BEOFRE INSTALLATION
VOID
CAST IN CONCRET BRACKET TO CONNECT I BEAM I BEAM AND BRACKET TO BE WELDED IN SHOP
4
GLASS DETAIL
3
1:5
STAINLESS STEEL BRACKET TO HOLD GLASS FLOOR
3
C
A402
Section 02 1 : 20
STAINLESS STEEL BRACKET TO HOLD GLASS FLOOR
I BEAM TO SUPPORT BRACKET TO BE WELDED IN SHOP BEOFRE INSTALLATION
B
1
A
A402
I BEAM TO BE ATTACHED WITH CONCRETE SLAB
4
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV DESCRIPTION
PANEL A
PANEL B
PANEL B
PANEL B
PRELIMINARY
STATUS:
WT 01 MODULAR GLASS PANEL
DATE
DYNAMIC ARCHITECTS
Level 5
Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
22500
CLIENT:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:
DYNAMIC ARCHITECTS
2
LONG SECTION
TITLE:
DETAIL 01 GLASS FLOOR
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
SCALE AT A1:
N/A
1 : 20
PROJECT NO:
DATE:
01.03.18 Author Checker DRAWING NO:
001 0
10
20
CHECKED:
DRAWN:
REVISION:
4
A402 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
D
7807
A
B
A305
8
1
A403
A300
2750
3000
2307
2750
WT08
WT08
WT08
7807
WT08
3000
CW03
Notes:
C
2750
2308
2750
INTERIOR
4
EXTERIOR
3310
Level 6
24 23
27000
22
WT07
2250
6
A403
D05
19 18
STEEL STAIR CASE ATTACHED TO STEEL PLATE ON SLAB. CONNECTION POINTS WELDED AT STRINGER EDGE
17
24 EQ RISERS 250MM GOINGS
INTERIOR
16 15 14 13
A403
7
1
11
A403
10 9 8
2250
7
WT03
WT07
24 RISERS AT 250MM
12
WT03
EXTERIOR
CW01
4600
1500
1958
21 20
6 5 4 3 2 1
3
Level 5
5
C
1
A300
A403
8
B
A305
D
A
DT01
22500
STAIRS PLAN LAYOUT
6
STAIRS SECTION 01 1 : 50
1 : 50
4
D
A
30MM ANODIZED ALUMINIUM HANDRAIL
6
B
A305
8
1
A403
A300
C
A403
1585
83 52
24
52
Level 6
23
27000
27000 5MM STEEL CABLE BALUSTRADE 84
Level 6
0
24
CUSTOM STEEL CABLE CLAMP
EXTERIOR
INTERIOR
750
22 21 20
TENSION CABLE BALLUSTRADE ATTACHED TO I BEAM SPACED 120MM TO ADJACENT
19 12MM ROUND STEEL HANDRAIL SUPPORT CONNECTED TO STEEL CLAMPS
18
125
17 1500
16 CUSTOM STEEL CABLE CLAMP 15 14
MAIN FEATURE STAIRS WITH WIRE BALUSTRADE. REFER TO DETAIL
Level 5 22500
13 4500
CUSTOM STEEL WIRE CLAMP BOLTED TO SHS SUB-LANDING
2
BALLUSTRADE HANDRAIL DETAIL
7
1:2
STAIRS ELEVATION 1 : 50
80
110
4
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV DESCRIPTION
PRELIMINARY
STATUS:
35
DATE
VINYL TREAD COVERING FLUSH AGAINST RISE
CENTRAL BALLUSTRADE HANDRAIL
DYNAMIC ARCHITECTS
35
2250
NICKEL NON-SLIP INSERT
Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
10MM FOLDED STEEL TREAD 188
BENT STEEL SUPPORT WELD ON STRINGER
2 A403
STEEL BEAMS SUPPORTING GLASS REFER A304 FOR DETAILING
24
Level 5
23
22500
7.82°
50
GOING PROFILE BENT TO BACK OF RISER
CLIENT:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION
332
ARCHITECT:
DYNAMIC ARCHITECTS
22 21
RISER PROFILE
20 19
55
LANDING ON 150X80X9.0 SHS BEAM
PRIMARY STEEL STRINGER 50MM
TITLE:
DETAILS 02 STAIRS
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
18 17
SCALE AT A1:
N/A PROJECT NO:
8
STAIRS SECTION 02 1 : 20
1
STAIRS SECTION 01 - DETAIL 1:5
DATE:
01.03.18 Author Checker DRAWING NO:
001 0
10
20
CHECKED:
DRAWN:
REVISION:
4
A403 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
Notes:
3 3 WT02 BRICK VENEER. BRICK TO WRAP AROUND THE CORNER AND ATTACH WT01 TUBE FRAME
400x400mm CONCRETE COLUMN
2000
WT07 CURTAIN WALL TO FIT BETWEEN WT03 BLCOK VENEER WALL
A
WORKSHOP TO BE EQUIPED WITH SPECIFIC MACHINERY. REFER TO FACULTY OFFICE
ROD BRACES TO SUPPORT HANGING BOX BY ATTACHING TO BEAM AND FLOOR SLAB ABOVE
WT07
SCONCE LAMP TO BE ATTACHED TO CONCRETE COLUMN
2051
SUB‐MEZZANINE ‐ PRATT FLAT TRUSS SYSTEM. MEASUREMENTS AND ATTACHMENTS AS PER DRAWING SPECIFICATIONS
3033
ROD BRACES TO CONNECT SUB‐FLOOR TRUSS TO ABOVE I BEAMS AND CELLULAR BEAMS. ROD TENSION AS PER NCC REQUIREMENTS AND MANUFACTURERS' SPECIFICATIONS
FT03
MULLION TO ATTACH INTO GYPSUM PLASTER BLOCK VENEER
D A305
RIGID INSULATION GYPSUM PLASTER
WT03
SCONCE LAMP TO BE ATTACHED TO CONCRETE COLUMN
WT07 FT02 150mm HOLLOWCORE CONCRETE SLAB AIR GAP/TIMBER STACK
Level 5 22500
FT03
B
FT02 C
EXPOSED STEEL BEAM TO BE FIRERATED WITH INTUMESCENT PAINT
HANGING BOX MULLION TO ATTACH ONTO WALL ABOVE
PENDANT LIGHT TO ATTACH INTO FLOOR SLAB ABOVE
ROD BRACES TO ATTACH INTO BEAM ABOVE
212
A304
400
LT02
2000
C
470
FT03 STEEL FRAME TO ATTACH INTO FLOOR SLAB AND COLUMN
3310
ROD BRACES WIRE TO BE INSTALLED BEHIND 150x50mm STEEL MULLION
12/05/18
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV DESCRIPTION
DATE
PRELIMINARY
STATUS:
DIAGRONAL TENSION WIRE TO ATTACH INTO FLOOR SLAB
Level 4
DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
18000
FT01 51
FT03
Final Package
3
2000
FT01 150mm CONCRETE HOLOCORE
4
CLIENT:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION
600
WT04
DYNAMIC ARCHITECTS
LT01
SUB FLOOR TIMBER TRUSS EXPOSED AS FEATURE CEILING. TIMBER FIRE RATING AS PER NCC REQUIREMENTS
1509
1625
WT03
LT01
ARCHITECT:
D
PENDANT LIGHTING TO ATTACH INTO FLOOR SLAB ABOVE
TITLE:
DETAILS 03 HANGING BOX
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
230
SCALE AT A1:
LT04
1233
N/A
1541
PROJECT NO:
1
DETAIL 01 SECTION 1 : 10
2
DETAIL 01 PLAN 1 : 20
DATE:
01.03.18 Author Checker DRAWING NO:
001
2803 0
10
20
CHECKED:
DRAWN:
REVISION:
4
A404 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
D
E
D
E
RECESSED CEILING WITH LIGHTING
DT02 900mm DOOR. REFER TO PLAN
TIMBER PANEL CEILING IN LOBBY SPACE. REFER TO RCP PLAN
WT08 TIMBER STUD WALL
TA05 LT01
COAT HOOK TO BE INTALLED ONTO EVERY DOOR. FOLLOW AS1428.1-2009 16.5
1
A510
3
1
A510
FT01
LT05
4
4 3
DISABLED TOILET LAYOUT TO COMPLY AUSTRALIAN STANDARDS. AS1428.1-2009 15.2.8; FIG 52
LT05
D02
D02
FT04 WT06
2
2
TA02
3168
MI03 LT01
TB01 TA01 TB06
LT05
TA03
TA04
JA04
JA02
D02
D02
D02
D02
LT01
CLEANING ROOM TO BE EQUIPED WITH ADEQUATE FACILITIES
LT05
DISABLED TOILET LAYOUT TO COMPLY AUSTRALIAN STANDARDS. AS1428.1-2009 15.2.8; FIG 52
5
5 LT01
JA03
JA01
1534
D07
MI02
TA03
MI02
D07
970mm TIMBER STUD WALL
TA02
150mm PLUMING SYSTEM WITHIN THE STUD WALL
LT01
LT01
FT04
LT01
LT01
MI01
TA04
D07
MI01
HAND TOWL AND DISPENSER TO MANUFACTURE'S DETAIL
D07
TA01
D07
FT04
2240
TA01
LT01
D07
LT01
TB01
LT01
900
FLUSHING CONTROL MOUNTED ON STUD WALL
TA04 3
TA03
TA04
TA04
TA04
WT08
TA04
1
1
TA04
WT06
TA01
4
D07
2
TA04 TA01
A511
1000
TB01
4
2
900
TOILET BOWL TO BE COMPLIED TO AUSTRALIAN STANDARDS. FOLLOW AS 1428.1-2009
A511
TA02
3
30mm LAMINATED TOILET PARTITION WALL
1000
TA03
TOILET CLEANING EQUIPMENT TO BE INSTALLED INTO ALL CUBICLE
TA02
TA02
TB02
D07
D07
TB01
D07
150mm PLUMBING CAVITY WITH THE TIMBER STUD WALL
LT01
900
TB01
1534
TA03
1604
8
5
TB02
A510
TA03
LT01
TA02
6
8
5
TA03
A510
6
DULE TOILET PAPER DISPENSER TO BE INSTALLED TO ALL CUBICLE. FOLLOW AS 1428.1-2009 15.2.6
7
7
1020
TA02 D07
LT01
6
6
CUBICLE WALL TO BE 600mm WIDTH MIN.
LT01
D07
TB01
D07
TB01
LT01
D07
300mm CONCRETE FACADE
FT04 60x60mm OZ TILE
WT01 MODULAR GLASS PANEL TO BE OPAQUE. REFER TO ELEVATION
1
0
10
20
30
TOILET UNIT TB01: CAROMA LIANO EASY HEIGHT INVISI II No.766500W TB02: CAROMA INTEGRA URINAL No.6651022W
60
70
80
90
100
TOILET AMENITY TA01: CAROMA MOON 500 WALL BASIN 1TH WHITE No.EU550715W TA02: HONANA BC‐621 CREATIVE TOILET BRUSH No.1226292 TA03: CAROMA VIRTU CIRCIT DOUBLE TOILET PAPER No.0961C TA04: DYSON AIRBLADE DB FT05 300678‐01 TA05: KOALA KARE STAINLESS BABY CHANGE TABLE HORIZONTAL KB110‐SSRE TA06: 90 LH+450 STRAIGHT GRAB RAIL SET RBA4090‐345
RECESSED CEILING WITH LIGHTING FINISHNG AT FACADE
MALE URINALS INSTALLED TO COMPLY AS1428.1-2009. REFER TO MANUFACUTER'S DETAIL
2
1 : 20
MIRROR MI01: ASI INTER‐LOCK FRAMED MIRROR 10‐0600‐V3036 MI02: ASI INTER‐LOCK FRAMED MIRROR 10‐0600‐V3636 MI03: ASI INTER‐LOCK FRAMED MIRROR 10‐0600‐V1839
50
WT08 90mm TIMBER STUD WALL
RECESSED CEILING WITH LIGHTING FINISHNG AT FACADE
TYPICAL AMENITIES PLAN
Notes:
40
WASH BASIN TO COMPLY AS1428.1-2009 15.3
4
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV
STATUS:
DESCRIPTION
PRELIMINARY
DATE
TYPICAL AMENITIES RCP 1 : 20
DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
CLIENT:
SITE:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:
DYNAMIC ARCHITECTS
TITLE:
81/89 BOUVERIE ST, CARLTON VIC 3053
SCALE AT A1:
TYPICAL AMENITIES PLAN
PROJECT NO:
1 : 20 001
DATE:
DRAWN:
CHECKED:
01.03.18 Author
Checker
DRAWING NO:
REVISION:
A500
NO RT H
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS.CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
HAND TOWL AND DISPENSER TO REFER MANUFACTURE'S DETAIL
4
CEILING CAVITY TO FIT VENTS
E
2100
2768
1524
50
828
587
180
2745
180 183
TB06
180
533
1219
80
MIRROR AND HAND WASH POSITION TO COMPLY AS.1428.12009
FEATURE WALL AND COVER FOR PLUMBING CAVITY
TB06
948
MI01 D07
MI02
587
466
TA01
1200
180
DISABLED TOILET BOWL TO COMPLY AS1428.1-2009 15.2.8
TA02
TA03
TB01
80mm ALUMINIUM PILASTERS SHOES
TA02
TA01
534
805
TB01
150mm PLUMBING SYSTEM WITHIN THE STUD WALL CAVITY 610
FT01
1200
356
534
TA04
90
8270
TA03
534
TA04
TA01
356
479
TA01
600
D07
TB02 HANDWASH BASIN TO COMPLY WITH AS1428.1-2009
50
DULE TOILET PAPER DISPENSER 2335
MI03
1161
890
600
2700
MI03
1200
FIBER GLASS REINFORCED PLASTIC WALL. REFER TO MANUFACTURE' S DETAIL
HANDRAILS TO COMPLY AS1428.1-2009
1041
400
505
80mm ALUMINIUM HEAD RAIL
MIRRORS TO COMPLY AS1428.1-2009
DISABLED TOILET TO BE EQUIPED WITH HANDRAILS COMPLYING AS1428.1-2009
2340
2050
FIBER GLASS REINFORCED PLASTIC WALL. REFER TO MANUFACTURE'S DETAIL
624
1460
RECESSED CEILING
1900
200
200
FIBER GLASS REINFORCED PLASTIC WALL. REFER TO MANUFACTURE'S DETAIL
D02
3600
200
800
200
5
Level 3
80
850
RECESSED CEILING WITH LIGHT FITTING 200
50mm PLASTERBOAR D CEILING
6
150
150
150
LIGHTING FIXTURE TO REFER MANUFACTURE'S DETAIL
D
13500
DISABLED E
5
1 : 20
6
1 : 20
D
1500
2100
200
200 200
200 180
300
6
RECESSED CEILING
200 200
1 : 20
5
150
150
E
MALE N
933
150
2
1 : 20
MALE E
2768
1087
1594
200
50
990
3600
50mm PLASTERBOARD CEILING
550
1
DISABLED N
534
80
40mm RIGID INSULATION 80mm ALUMINIUM HEADRAIL
10mm GYPSUM BOARD 150mm CONCRETE WALL
TIMBER FEATURE CLADDING WALL
235 61 235 61 235 61 235 100 1500
765
287
1200
TA04
TA04
TB02
TA04
356
80mm ALUMINIUM PILASTERS SHOES
534
TB01
TA04
TB02
610
HAND TOWL AND BIN UNIT
PLUMBING CAVITY
351
51
1015
TB02 TA01
435
624
TIMBER FEATURE CLADDING WALL
478
610
PLUMBING CAVITY CAP
TA03
DISABLED TOILET BOWL TO COMPLY AS1428.1-2009
805
TA05
533
TB06
438
TB01
305
TIMBER CLADDING WALL
1200
1200
477
TA02
TA03
326
MALE URINAL TO REFER MANUFACTURE R'S DETAIL
D02
PLUMBING CAVITY CAP
FLUSHING PIPING TO BE INSTALLED WIHTIN PLUMBING CAVITY SPACE
395
110 175
D02
TB06
FIBER GLASS REINFORCED PLASTIC WALL. REFER TO MANUFACTURE'S DETAIL
TOILET BOWL TO COMPLY AS1428.1-2009
HANDRAILS TO COMPLY AS1428.1-2009
TIMBER STUD WALL WITH FEATURE TIMBER COMPOSITE CLADDING
100
1500
30mm PARTITION WALL
FIBER GLASS REINFORCED PLASTIC WALL. REFER TO MANUFACTURE'S DETAIL
TA05
2240
2350
2350
100mm TIMBER STUD WALL
TIMBER STUD WALL TO BLOCK VIEW
Level 3 13500
3
DISABLED S
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS.CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
0
10
4
1 : 20
20
30
TOILET UNIT TB01: CAROMA LIANO EASY HEIGHT INVISI II No.766500W TB02: CAROMA INTEGRA URINAL No.6651022W
Notes:
40
MIRROR MI01: ASI INTER‐LOCK FRAMED MIRROR 10‐0600‐V3036 MI02: ASI INTER‐LOCK FRAMED MIRROR 10‐0600‐V3636 MI03: ASI INTER‐LOCK FRAMED MIRROR 10‐0600‐V1839
50
60
70
80
90
100
DISABLED W
7
1 : 20
TOILET AMENITY TA01: CAROMA MOON 500 WALL BASIN 1TH WHITE No.EU550715W TA02: HONANA BC‐621 CREATIVE TOILET BRUSH No.1226292 TA03: CAROMA VIRTU CIRCIT DOUBLE TOILET PAPER No.0961C TA04: DYSON AIRBLADE DB FT05 300678‐01 TA05: KOALA KARE STAINLESS BABY CHANGE TABLE HORIZONTAL KB110‐SSRE TA06: 90 LH+450 STRAIGHT GRAB RAIL SET RBA4090‐345
MALE S
4
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV
STATUS:
DESCRIPTION
PRELIMINARY
DATE
8
1 : 20
DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
MALE W
CLIENT:
1 : 20
SITE:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:
DYNAMIC ARCHITECTS
TITLE:
81/89 BOUVERIE ST, CARLTON VIC 3053
SCALE AT A1:
TYPICAL AMENITIES ELEVATIONS 01
PROJECT NO:
1 : 20 001
DATE:
DRAWN:
CHECKED:
01.03.18 Author
Checker
DRAWING NO:
REVISION:
A510
4
E
6
STEEL BEAM BETWEEN COLUMNS
5
50 100
RECESSED CEILING LIGHT SOURCE WITHIN CEILING CAVITY 1634
2100
200
200
550
200
4777
50mm PLASTERBOARD CEILING
80mm ALUMINIUM HEADRAIL
80
80
80
50
600
30 270 30
600
30 270 30
505
505
1080 600
30 270 30
600
30
30mm PARTITION WALL 1634
297 30
1450
FIBER GLASS REINFORCED PLASTIC WALL. REFER TO MANUFACTURE'S DETAIL
HAND WASH AND MIRROR POSITION TO COMPLY AS1428.1-2009
MI01
120
JANATORIAL EQUPMENTS
D07
D07
2335
JA04
2300
800
180
D07
JA02
D07 JA03
765
237
HAND TOWL AND BIN UNIT
TA01
587
TA04
TB01
435
643
TA04
80
80mm ALUMINIUM PILASTERS SHOES
Level 3
80
TA04
763
TA04
13500
1
FEMALE E
2
1 : 20
FEMALE N 1 : 20
5
E
FEMALE TOILET INTORIOR
6
3734 1010
80
50
50mm PLASTERBOARD CEILING
80
1440
200
LIGHT SOURCE WITHIN CEILING CAVITY
80mm ALUMINIUM HEADRAIL 1750
900
505
550
200
150
150
RECESSED CEILING
30
120 30
600
30
356
300
580
140100100
915
30
30mm PARTITION WALL 519
90
600
50
1200
300
587
D02
690
800
180
MI02 HAND WASH AND MIRROR POSITION TO COMPLY AS1428.1-2009
D07
D07
915
TA03
TB01
TB01
471
TA04 356
TOILET BOWL AND PAPER DISPENSER TO COMPLY AS1428.1-2009
TA03
Level 3
80
80
TA01
534
534
HAND TOWL AND BIN UNIT
TB01
435
TA01
TA01
TA03
1000
1200
1800
D07
MI01 2300
2840
FIBER GLASS REINFORCED PLASTIC WALL. REFER TO MANUFACTURE'S DETAIL
13500
3
FEMALE S
0
10
20
4
1 : 20
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS.CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.
30
TOILET UNIT TB01: CAROMA LIANO EASY HEIGHT INVISI II No.766500W TB02: CAROMA INTEGRA URINAL No.6651022W
Notes:
40
MIRROR MI01: ASI INTER‐LOCK FRAMED MIRROR 10‐0600‐V3036 MI02: ASI INTER‐LOCK FRAMED MIRROR 10‐0600‐V3636 MI03: ASI INTER‐LOCK FRAMED MIRROR 10‐0600‐V1839
50
60
70
FEMALE W
80
90
100
TOILET AMENITY TA01: CAROMA MOON 500 WALL BASIN 1TH WHITE No.EU550715W TA02: HONANA BC‐621 CREATIVE TOILET BRUSH No.1226292 TA03: CAROMA VIRTU CIRCIT DOUBLE TOILET PAPER No.0961C TA04: DYSON AIRBLADE DB FT05 300678‐01 TA05: KOALA KARE STAINLESS BABY CHANGE TABLE HORIZONTAL KB110‐SSRE TA06: 90 LH+450 STRAIGHT GRAB RAIL SET RBA4090‐345
6
1 : 20
4
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV
STATUS:
DESCRIPTION
PRELIMINARY
DATE
DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
AMENITIES AXONOMETRIC NTS
CLIENT:
SITE:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:
DYNAMIC ARCHITECTS
TITLE:
81/89 BOUVERIE ST, CARLTON VIC 3053
SCALE AT A1:
TYPICAL AMENITIES ELEVATION 02
PROJECT NO:
1 : 20 001
DATE:
DRAWN:
CHECKED:
01.03.18 Author
Checker
DRAWING NO:
REVISION:
A511
4
A
Notes: Sample Notes
B
INTERCHANGEABLE PANELS IN MULLIONS REPLACE GLAZING. 11 VARIATIONS FITTED WITHIN STEEL FRAME. REFER TO DRAWING A200 FOR PLACEMENT OF PANELS REFER TO SCHEDULE MATRIX (BELOW) FOR INSERT PANEL TYPES
ASSEMBLAGE OF PANELS INTO TYPICAL MODULE FRAME.
C
ALL GLAZED, ALUMINIUM ON FRONT SURFACE TO MAINTAIN DIMENSIONS. PANELS FIT INTO INBUILD MULLIONS AND HOUSINGS IN FRAMES
MODULAR CURTAIN WALL AND INDIVIDUAL MODULES ACT AS STRUCTURAL TRUSS SYSTEM THAT INCORPORATES ANGLED GLAZING AND SUNSHADES ON WESTERN AND NORTHERN BORDERS. MODULES BECOME CONTINUOUS CURTAIN WALL AND VERTICLE SPACE FRAME REFER TO DRAWING A401 FOR CONNECTIONS TO ADJACENT MODULES AND FLOOR PLATES
D
TYPE
PANEL A
PANEL B
PANEL C
PANEL D
CW01 MESH INSERT SUNSHADE PANEL
IGU DOUBLE GLAZE PANEL
IGU DOUBLE GLAZE PANEL
INSULATED ALUMIUM COMPOSITE PANEL (FUCSHIA)
1
CW02 MESH INSERT SUNSHADE PANEL
BLUE TINTED IGUE DOUBLE GLAZE PANEL
INSULATED ALUMIUM COMPOSITE PANEL (PEACH)
MESH INSERT SUNSHADE PANEL
BLUE TINTED IGUE DOUBLE GLAZE PANEL
IGU DOUBLE GLAZE PANEL
MESH INSERT SUNSHADE PANEL
ROSE TINTED IGUE DOUBLE GLAZE PANEL
MESH INSERT SUNSHADE PANEL
ROSE TINTED IGUE DOUBLE GLAZE PANEL
FACADE AXO
INSULATED ALUMIUM COMPOSITE PANEL (PEACH)
CW03
CW04
IGU DOUBLE GLAZE PANEL
INSULATED ALUMIUM COMPOSITE PANEL (ORANGE)
INSULATED ALUMIUM COMPOSITE PANEL (PEACH)
CW05
CW06 MESH INSERT SUNSHADE PANEL
INSULATED ALUMIUM COMPOSITE PANEL (FUCSHIA)
BLUE TINTED IGUE DOUBLE GLAZE PANEL
IGU DOUBLE GLAZE PANEL
INSULATED ALUMIUM COMPOSITE PANEL (FUCSHIA)
INSULATED ALUMIUM COMPOSITE PANEL (PEACH)
4
Final Package
12/05/18
3
Mid Sem Presentation
17/04/18
2
Preliminary Design
22/03/18
1
Project Set Up
03/03/18
REV DESCRIPTION
DATE
PRELIMINARY
STATUS:
CW07 MESH INSERT SUNSHADE PANEL
ROSE TINTED IGUE DOUBLE GLAZE PANEL
INSULATED ALUMIUM COMPOSITE PANEL (RED)
DYNAMIC ARCHITECTS INSULATED ALUMIUM COMPOSITE PANEL (PEACH)
Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au
CW08 MESH INSERT SUNSHADE PANEL
INSULATED ALUMIUM COMPOSITE PANEL (ORANGE)
ROSE TINTED IGUE DOUBLE GLAZE PANEL
INSULATED ALUMIUM COMPOSITE PANEL (ORANGE)
CLIENT:
RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:
CW09 MESH INSERT SUNSHADE PANEL
INSULATED ALUMIUM COMPOSITE PANEL (ORANGE)
INSULATED ALUMIUM COMPOSITE PANEL (RED)
CW10 MESH INSERT SUNSHADE PANEL
INSULATED ALUMIUM COMPOSITE PANEL (PEACH)
BLUE TINTED IGUE DOUBLE GLAZE PANEL
DYNAMIC ARCHITECTS
INSULATED ALUMIUM COMPOSITE PANEL (FUCSHIA)
INSULATED ALUMIUM COMPOSITE PANEL (RED)
TITLE:
GLASS FACADE ASSEMBLY
SITE:
81/89 BOUVERIE ST, CARLTON VIC 3053
SCALE AT A1:
DATE:
CHECKED:
DRAWN:
1 : 150 01.03.18 Author Checker PROJECT NO:
CW11 MESH INSERT SUNSHADE PANEL
IGU DOUBLE GLAZE PANEL
INSULATED ALUMIUM COMPOSITE PANEL (PEACH)
INSULATED ALUMIUM COMPOSITE PANEL (ORANGE)
DRAWING NO:
001
2
FACADE AXO - ASSEMBLY
0
10
20
REVISION:
4
A600 30
40
50
60
70
80
90
100
ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.