Project Saturn V Documentation

Page 1

PROJECT SATERN V PROJECT NAME: PROJECT LOCATION: ISSUE DATE: GROUP NAME: GROUP MEMBER: TUTOR NAME: SUBJECT NAME: SCHOOL NAME: SEMEESTER:

SATURN V 81/89 BOUVERIE ST, CARLTON VIC 2053 08/03/2018 DYNAMIC ARCHITECTS DANNY KWAK & JEAN VILJOEN EDWARD BERRY ARCH 1016 TECHNOLOGY 04 RMIT UNIVERSITY SEMESTER 1,2018

PROJECT SATURN V SHEET LIST WT A000 A001 A002 A100 A101 A102 A103 A104 A105 A106 A107 A108 A109 A110 A111 A112 A113 A114 A115 A116 A200 A201 A300 A301 A302 A304 A305 A400 A401 A402 A403 A404 A500 A510 A511 A600

Sheet Name TITLE SHEET SITE PLAN 01 SITE PLAN 02 BASEMENT FLOOR PLAN GROUND FLOOR PLAN LEVEL 01 PLAN LEVEL 02 PLAN LEVEL 03 PLAN LEVEL 04 PLAN LEVEL 05 PLAN LEVEL 06 PLAN LEVEL 07 PLAN LEVEL 08 PLAN LEVEL 09 PLAN ROOFTOP GARDEN PLAN ROOF PLAN REFLECTED CEILING PLAN 01 REFLECTED CEILING PLAN 02 REFLECTED CEILING PLAN 03 REFLECTED CEILING PLAN 04 ELEVATIONS ‐ NORTH & EAST ELEVATIONS ‐ SOUTH & WEST ZONE SECTIONS SECTION A SECTION B SECTION C SECTION D TYPICAL FACADE 01 TYPICAL FACADE 02 DETAIL 01 GLASS FLOOR DETAILS 02 STAIRS DETAILS 03 HANGING BOX TYPICAL AMENITIES PLAN TYPICAL AMENITIES ELEVATIONS 01 TYPICAL AMENITIES ELEVATION 02 SPECIAL DRAWINGS

Revision

SCALE

4

N/A

4

1:500

4

1:200

4

1:50

4

1:50

4

1:50

4

1:50

4

1:50

4

1:50

4

1:50

4

1:50

4

1:50

4

1:50

4

1:50

4

1:50

4

1:50

4

1:50

4

1:50

4

1:50

4

1:50

4

1:100

4

1:100

4

1:100

4

1:50

4

1:50

4

1:20

4

1:20

4

N/A

4

N/A

4

N/A

4

N/A

4

N/A

4

1:20

4

1:20

4

1:20

4

N/A

WALL SCHEDULE WT03 (INTERIOR) 230 BLOCK VENEER

WT 05 (INTERIOR) 200mm CONCRETE WALL

WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN

90mm MASONRY BLOCK 50mm RIGID INSULATION 80mm TIMBER BLOCK 10mm GYPSUM BOARD

150mm CONCRETE 40mm RIGID INSULATION 10mm GYPSUM BOARD

6mm LOW E COATED GLASS 12mm ARGON GAS 6mm LOW E COATED GLASS

WT02 (EXTERIOR) 270mm BRICK VENEER

WT 04 (INTERIOR) 300mm CONCRETE

WT 06 (INTERIOR) 90mm TIMBER STUD

WT08 (INTERIOR) 200mm FEATURE WALL

110mm MASONRY BRICK 40mm AIR GAP 40mm RIGID INSULATION 50mm TIMBER BLOCK 10mm PLYWOOD SUBSTRATE 20mm GYPSUM BOARD

10mm GYPSUM BOARD 40mm RIGID INSULATION 250mm POURED CONCRETE

10mm TIMBER CLADDING 20mm RIGID INSULATION 5mm AIR GAP 40mm TIMBER STUD 5mm AIR GAP 10mm TIMBER CLADDING

20mm TIMBER CLADDING 5mm AIR GAP 50mm RIGID INSULATION 100mm TIMBER STUD 5mm AIR GAP 20mm TIMBER CLADDING

DT 03 DOUBLE DOOR

DT 05 CURTAIN WALL (DOUBLE)

DT 07 TOILET DOOR

WT 01 (EXTERIOR) GLASS QUASI CURTAIN PANEL

DOOR SCHEDULE DT 01 SLIDING DOOR

GENERAL NOTES DT 02 SINGLE DOOR

DT 04 CURTAIN WALL (SINGLE)

1.

DT 06 FIRE EXIT DOOR

2. 3.

FLOOR SCHEDULE FT 01 150mm 6 CORE HC SLAB

FT 03 150mm GLASS FLOOR

FT 05 CAFE FLOOR 60x120mm PETITOT TILE

4.

30mm GLASS 50mm GLASS 50mm GLASS 20mm AIR GAP

5.

6. FT 02 300mm 4 CORE HC SLAB

FT 04 TOILET FLOOR 60x60mm OZ TILE

FT 06 CLASSROOM FLOOR 5mm SPHERA VINYL FLOOR

7. 8.

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS.CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.

0

10

20

30

Notes:

40

4

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV

STATUS:

50

60

70

80

90

100

DESCRIPTION

PRELIMINARY

DATE

THE INTENT OF THE DRAWINGS AND SPECIFICATIONS IS TO PROVIDE FOR A WATERTIGHT & WEATHER TIGHT BUILDING. THE CONTRACTOR SHALL REVIEW ALL DETAILS RELATING TO THIS INTENT AND BY BIDDING OR ENTERING INTO THIS CONSTRUCTION CONTRACT WARRANTS FOR ONE FULL YEAR THE ADEQUACY OF THESE DETAILS. SHOULD THE CONTRACTOR TAKE EXCEPTION TO THESE DETAILS, SHALL NOTIFY THE ARCHITECT PRIOR TO BIDDING. ANY DEVIATION FROM THIS GENERAL INTENT SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION. THE INTENT OF THE DRAWINGS AND SPECIFICATIONS IS TO PROVIDE FOR A PLUMB, LEVEL, AND SQUARE STRUCTURE UNLESS OTHERWISE NOTED. ANY DEVIATION FROM THIS GENERAL INTENT SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION. THE BUILDING SHALL BE CONSTRUCTED IN FULL COMPLIANCE WITH ALL APPLICABLE CODES, ORDINANCES AND REGULATIONS AS WELL AS THE DRAWINGS AND SPECIFICATIONS. ANY CODE DEFICIENCIES IN THE DRAWINGS RECOGNIZED BY THE CONTRACTOR SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE PLACEMENT OF THE BUILDING ON THE SITE AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS. DISCREPANCIES BETWEEN DRAWINGS AND ACTUAL SITE CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE BIDDING THE PROJECT OR THE COMMENCEMENT OF WORK. THE OWNER SHALL NOT BE RESPONSIBLE FOR CHANGES TO THE WORK DUE TO THE FAILURE OF THE CONTRACTOR TO FAMILIARIZE HIMSELF WITH EXISTING CONDITIONS DO NOT SCALE DRAWINGS: ALL DIMENSIONS SHALL HAVE PREFERENCE OVER SCALE AND BE FIELD VERIFIED AND COORDINATED WITH WORK OF ALL TRADES. IF NO DIMENSIONS ARE GIVEN OR DISCREPANCIES FOUND, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT FOR CLARIFICATION BEFORE BIDDING OR COMMENCING THE WORK. DETAILS ARE INTENDED TO SHOW METHOD AND MANNER OF ACCOMPLISHING WORK. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, ALL INCLUDED AS PART OF THE WORK. THE CONTRACTOR SHALL PROVIDE ALL PERMITS AND INSPECTION NECESSARY FOR THE PROPER EXECUTION OF THE WORK IN ACCORDANCE WITH APPLICABLE CODES AND GOVERNING REGULATIONS. THE CONTRACTOR SHALL VERIFY THE SIZES AND LOCATIONS OF ALL MECHANICAL AND ELECTRICAL EQUIPMENT PADS AND BASES, AS WELL AS POWER, WATER AND DRAIN REQUIREMENTS FOR SUCH EQUIPMENT WITH EQUIPMENT MFG. DEVIATION OF THE AFOREMENTIONED REQUIREMENTS SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION.

DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

CLIENT:

SITE:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:

DYNAMIC ARCHITECTS

TITLE:

81/89 BOUVERIE ST, CARLTON VIC 3053

TITLE SHEET

SCALE AT A1:

DATE:

DRAWN:

As indicated 01.03.18 D.K & J.V PROJECT NO:

001

DRAWING NO:

A000

CHECKED:

E.B REVISION:

4


Notes: RY BAR

SURROUNDING TREE TYPES

EET STR

Quercus rubra: RED OAK

Angophora costata: SMOOTHBARKED APPLE

Ulmus x hollandica: ELM

Platanus x acerifolia: LONDON PLANES

Melia Azedarach: WHITE CEDAR

Corymbia ficifolia: RED FLOWERING GUM

QUEENS BERRY STREET

Flindersia australis: AUSTRALIAN TEAK

Celtis australis: WHITE CEDAR

EY KEL BER ON STR EET

4

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV DESCRIPTION

DATE

PRELIMINARY

STATUS:

ETH ZAB ELE

SWANS T

BOUVE RIE STR EET

LEICES TER ST

EET STR

REET

Eucalyptus leucoxylon: YELLOW GUM

DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

EET STR

CLIENT:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:

DYNAMIC ARCHITECTS TITLE:

SITE PLAN 01

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

SCALE AT A1:

1:500

PROJECT NO:

DATE:

1

1 : 500

0

10

20

CHECKED:

DRAWN:

01.03.18 D.K & J.V DRAWING NO:

001

SITE PLAN 01

NORTH

E.B REVISION:

4

A001 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


Notes: SITE ANALYSIS: NOTABLE BUILDINGS

3

1. 2. 3. 4. 5. 6. 7. 8. 9.

9 2

MELBOURNE & METROPOLITAN TRAMWAY BOARD FORMER PRIMARY SCHOOL NO.2363 MELBOURNE UNIVERSITY SCHOOL OF EDUCATION AUSTRALIAN MENUFACTURING WORKERS' UNION FORMER INDEPENDENT MISSION HALL PIXEL 205 SWANSTON SQUARE DEVELOPMENT SHOP (HO99) METROPOLITAN FIRE BRIGADE FIRE STATION NO.3

1 8

QUEENS BERRY STREET

4

5

BOUVE RIE STR EET

6 4

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV DESCRIPTION

DATE

PRELIMINARY

STATUS:

DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

CLIENT:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION

7

ARCHITECT:

DYNAMIC ARCHITECTS TITLE:

SITE PLAN 02

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

SCALE AT A1:

1:200 PROJECT NO:

1

SITE PLAN 02 1 : 200

DATE:

10

20

CHECKED:

DRAWN:

01.03.18 Author Checker DRAWING NO:

001 0

NORTH

REVISION:

4

A002 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


Notes: A200

DOOR TYPES

N

1

2

DT 01 SLIDING DOOR B

3

4

A302

5

6

DT 02 SINGLE DOOR

22804 500

4600

4600

4600

3927

3927

650 DT 03 DOUBLE DOOR

WT04

300

295

A

DT 04 CURTAIN WALL (SINGLE) DT 05 CURTAIN WALL (DOUBLE)

WT05

WORKSHOP TO BE EQUIPPED WITH SPECIALED MACHINES. REFER TO MANUFACTURE'S DETAIL

UP

3495

3000

SWITCHBOARD 07

DT 06 FIRE EXIT DOOR

DT 07 TOILET DOOR

WT04

FT02

470

B

400

400

WALL TYPES

WT 01 (EXTERIOR) GLASS QUASI

UP

WT04

D06

04

WT02 (EXTERIOR) 270mm BRICK VENEER

WORKSHOP

LOBBY 02

05 2175

FIRE ESCAPE STAIRS 02

WT03 (INTERIOR) 230 BLOCK VENEER

FT02 10772

FT02

16304

500

3000

WT 04 (INTERIOR) 300mm CONCRETE

WT 05 (INTERIOR) 200mm CONCRETE WALL

LIFT SERVICE D05

LOBBY FOR BIKE PARKING AND SERVICE LIFT

WT 06 (INTERIOR) 100mm TIMBER STUD

2000

A301

7807

A

WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN

BIKE STORAGE

FLOOR TYPES

06

W

E

A200

FT 01 150mm 6 CORE HC SLAB

FT02

C

FT 02 300mm 4 CORE HC SLAB

D01 LOBBY 01 03

WT06

WT06 D02

FT02

FT 03 150mm GLASS FLOOR

1905

DULE HEIGHT 10 BIKE PARKING. REFER TO MANUFACTURER'S DETAIL

WT04

FT04

FT 04 TOILET FLOOR

FT04 IN SHOWER ROOM TO SLOAP FOR WATERPROOFING

D07

4193

5325

LOCKERS AND BIKE EQUIPMENT TO REFER MANUFACTURER'S DETAIL

WT07

FT 05 CAFE FLOOR

SHOWERS FT04 D02

WT04

1880

5866

8084

02

FT 06 CLASSROOM FLOOR

D07

D WT04

D02

WT04

WT06

SUBSTATION

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18 DATE

PRELIMINARY

STATUS:

08

DYNAMIC ARCHITECTS

FT02 WT05 D06

PLANTS TO BE CONNECTED TO EACH FLOOR VIA SURVICE SHAFT, REFER TO PLAN

Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

D02 UP

4127

WT06

TOILET UNISEX

FT04

01 FIRE ESCAPE STAIRS 01

SERVICE SHAFT [MAIN]

UP

E

D07

D07

D07

D07

D07

FT04 TO BE WATERPROOFED IN TOILET AND SLOPE FOR WATER DRAIN

D07 D07

2804

WATER TANK FT02 09

D07 FT04

LIFT 02

4

REV DESCRIPTION

1880

LIFT 01

UP

A201

2602

WT08 (INTERIOR) 200mm FEATURE WALL

CLIENT:

UP

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:

300

336

RAINWATER APTURED ON ROOF TO BE RECYCLED THROUGH WATER TANK

1

BASEMENT 1 : 50

S A201

1000

200

DYNAMIC ARCHITECTS

6950

ROOM LEGEND 1. TOILET UNISEX 2. SHOWERS 3. LOBBY 01 4. LOBBY 02 5. WORKSHOP 6. BIKE STORAGE 7. SWITCH BOARD 8. SUBSTATION 9. RAINWATER TANK

TITLE:

BASEMENT FLOOR PLAN

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

SCALE AT A1:

1:50

PROJECT NO:

DATE:

10

20

CHECKED:

DRAWN:

01.03.18 D.K & J.V DRAWING NO:

001 0

NO RT H

E.B REVISION:

4

A100 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


Notes:

QUEENSBERRY STREET

DOOR TYPES

DT 01 SLIDING DOOR

A200 DT 02 SINGLE DOOR

N

1

2

500

B

3

4600

4600

295

DT 03 DOUBLE DOOR

6

3927

3927

DT 04 CURTAIN WALL (SINGLE)

940

WT02

REFER TO A200 FOR CURTAIN WALL TYPE

1

FT07

CW

DT 05 CURTAIN WALL (DOUBLE)

A600

DT 06 FIRE EXIT DOOR

D05

14

9

15

8

16

7

17

6

18

5

19

4

20

3

21

2

22

3

23

4

24

5

UP

FIRE ESCAPE STAIRS 02

WT05

WALL TYPES

D03

2

6

8 9

WT 05 (INTERIOR) 200mm CONCRETE WALL

11

CAFE FURNITURES TO BE POSITIONED TO ALLOW FREE FLOW MOVEMENT ACROSS SITE

7407

4000

LIFT SERVICE

8007

7807

OVERHEAD

A301

WORKSHOP EXHIBITION

MAIN FEATURE STAIRS

02

LOBBY

FT02 UP

14

WT05

15 16

CW

17

2541

2500

18

400

7454

W

21

CURTAIN WALL WITHIN BRICK VENEER WALL REFER TO DETAILS

C

22

3110

3793

3000

4193

D02

FT05

DW 6078

1800

2315

WT03

WT08 WT08

D03

LIFT 01

LIFT 02

CAFE KITCHEN 06 FT05

D02 CAFE COOL ROOM

2350

D

07

E

FT 02 300mm 4 CORE HC SLAB

A200

FT 03 150mm GLASS FLOOR

08 WT05

WT04 8

FT02

7

6

5

4

3

2

UP 10

200

11

2740

9

1

FT 06 CLASSROOM FLOOR 4

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV DESCRIPTION

DATE

PRELIMINARY

STATUS:

DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

FIRE ESCAPE STAIRS 01

D07

23 22 21

UP

SERVICE SHAFT [MAIN]

12

951

D07

D07

04 FT04

TOILET UNISEX

WT06

Disabled Toilet

CLIENT:

FT04 TOILET FLOOR TO BE WATERPROOFED AND SLOPED FOR DRAINAGE

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:

DYNAMIC ARCHITECTS

03

UP

9470

D02

FT04

D06

13 14 15 16 17 18 19 20

SERVICE SHAFT [WORKSHOP]

FT 05 CAFE FLOOR

WT05 24

2500

WT02

FT 04 TOILET FLOOR

REFUSE STORAGE UP

RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL

3596

DW

951

FT 01 150mm 6 CORE HC SLAB

05

1800

WT03

4127

LANSDOWNE PLACE

WT08

CAFE SERVICE

WT07

300

4014

S A201

GROUND FLOOR

FLOOR TYPES

FT05 CAFE FLOOR TO BE WATERPROOFED AND SLOPED FOR DRAINAGE

WT04

WT04

WT08 (INTERIOR) 200mm FEATURE WALL

24

D01

E

WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN

23

WT03

1 : 50

740

20

2103

1

400

19

2893

A201

1600

REFER TO A200 FOR CURTAIN WALL TYPE

FT07

13

WT 06 (INTERIOR) 100mm TIMBER STUD

TENSION WIRES TO SUPPORT MAIN FEATURE STAIRS AND HANDRAILS

01

WT02

WT 04 (INTERIOR) 300mm CONCRETE

10

12

A

WT03 (INTERIOR) 230 BLOCK VENEER

CURTAIN WALL WITHIN BLOCK VENEER WALL REFER TO DETAILS

VOID ABOVE REFER TO LEVEL 1 PLAN

7

10802

WT02 (EXTERIOR) 270mm BRICK VENEER

400

1

WT07

WT 01 (EXTERIOR) GLASS QUASI

WT07

21 11

D06

DT 07 TOILET DOOR

BOUVERIE STREET

1

D06

OVERHEAD

1500

B

D01

10

UP

WT07

13

2825

UP

11

56 50

WT 02 TO WRAP AROUND WT03 EXPOSING BRICK AND KEEPING BLOCKS INTERNAL

12

3000

5

4600

WT07

A

4

A302

300

1000

200

1645

970

955

970

2300

WT04

ROOM LEGEND 1. LOBBY 2. WORKSHOP EXHIBITION 3. TOILET UNISEX 4. TOILET DISABLED 5. CAFE SERVICE 6. CAFE KITCHEN 7. CAFE COOL ROOM 8. REFUSE STORAGE

TITLE:

GROUND FLOOR PLAN

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

SCALE AT A1:

1:50 PROJECT NO:

DATE:

10

20

CHECKED:

DRAWN:

01.03.18 D.K & J.V DRAWING NO:

001 0

NO RT H

E.B REVISION:

4

A101 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


Notes: DOOR TYPES

A200

DT 01 SLIDING DOOR

N

1

2

500

B

3

4600

4

A302

4600

5

4600

6

3927

3927

324

DT 02 SINGLE DOOR

617 DT 03 DOUBLE DOOR

WT02

CW

DT 04 CURTAIN WALL (SINGLE) DT 05 CURTAIN WALL (DOUBLE)

1032

2081

5

19

4

20

3

21

2

22

UP

CONCEALED MACHINE ROOM FOR VERTICAL WIND TUNNEL

FT03

1887

2

23 24

3

VOID

WT 01 (EXTERIOR) GLASS QUASI WT02 (EXTERIOR) 270mm BRICK VENEER

5

D06

6 7

9

3600

10000

7807

12

WT07

WT07

WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN

MEETING ROOM 01

MEETING ROOM 02

07

08

FT01

FT01

UP

13 14 15

2800

16

WT04

17 18 19

1802

CONCEALED MACHINE ROOM FOR VERTICAL WIND TUNNEL

W

WT 06 (INTERIOR) 100mm TIMBER STUD

2988

3200

WT 05 (INTERIOR) 200mm CONCRETE WALL

TENSION WIRES TO SUPPORT MAIN FEATURE STAIRS AND HANDRAILS

MAIN FEATURE STAIRS

FT02

D05

WT 04 (INTERIOR) 300mm CONCRETE

8983

11

VERTICAL WIND TUNNEL TEST ROOM TO BE EXPOSED REFER TO DETAIL

06 LIFT SERVICE

WT07

10

WORKSHOP

A301

WT03 (INTERIOR) 230 BLOCK VENEER

8

WT05

20 21

6030

CW

22

WT08 (INTERIOR) 200mm FEATURE WALL

FLOOR TYPES

E

A200

FT 01 150mm 6 CORE HC SLAB FT 02 300mm 4 CORE HC SLAB

23

D04

24

OVERHEAD

4130

400

7454

400

WT07

CORRIDOR 01 3110

4193

VERTICAL WIND TUNNEL TO BE LINKED WITH FLIGHT SIMULATOR MACHINES

D04

WORKSHOP TO BE EQUIPED WITH SPECIFIC MACHINERY. REFER TO FACULTY OFFICE

1785

C

04

D01

FT01

FT 03 150mm GLASS FLOOR

FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

FT 04 TOILET FLOOR

D04

4384

2190

FT 05 CAFE FLOOR

5956

FT 06 CLASSROOM FLOOR

3085

A201

WALL TYPES

BALUSTRADE AND HANDRAILS TO BE INSTALLED TO EDGE OF FT03

4

2988

FIRE ESCAPE STAIRS 02

1

REFER TO A200 FOR CURTAIN WALL TYPE

18

6450

17

6

HORIZONTAL CURTAIN PANELS AS CEILING FROM MAIN ENTRANCE

05

5132

7

CORRIDOR 02

5875

16

2950

8

3330

DT 07 TOILET DOOR

2875

15

2944

9

1793

14

1007

3000

10

1

2094

13

UP

B

2688

UP

11

DT 06 FIRE EXIT DOOR

FT03 GLASS FLOOR CANTERLEVERED TO HAVE BALUSTRADE

6887

12

A

REFER TO A200 FOR CURTAIN WALL TYPE

295

A

WT02

WT07

MEETING ROOM 03

OVERHEAD

D

WT08

09 FT01 LIFT 01

LIFT 02

D02

7

6

5

4

3

2

WT06

1

9 10 11

FIRE ESCAPE STAIRS 01

TOILET DISABLED

23 22 21

UP

SERVICE SHAFT [MAIN]

12

951

A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL

1

Level 1 1 : 50

RUBBISH CHUTE

200

2500

RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL

335

3943

336

1000

D07

FT04

01

TOILET FEMALE

D07

200

1900

TOILET MALE

02

Preliminary Design

22/03/18

1

Project Set Up

03/03/18 DATE

PRELIMINARY

FT04

100

2850

DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

FT04 TOILET FLOOR TO BE WATERPROOFED AND SLOPED FOR DRAINAGE CLIENT:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION

03

FT04

UP

6770

951

13 14 15 16 17 18 19 20

D07

2600

UP

WT05

270

2

D02

24

WT05

17/04/18

1300 UP

D02

WT05 D05

8

SERVICE SHAFT [WORKSHOP]

12/05/18

Mid Sem Presentation

STATUS:

4509 4127

9470

WT04

Final Package

3

REV DESCRIPTION

WT04

E

4

100

2056

534

FT04 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

ARCHITECT:

DYNAMIC ARCHITECTS

S A201

ROOM LEGEND 1. TOILET DISABLED 2. TOILET FEMALE 3. TOILET MALE 4. CORRIDOR 01 5. CORRIDOR 02 6. WORKSHOP 7. MEETING ROOM 01 8. MEETING ROOM 02 9. MEETING ROOM 03

TITLE:

LEVEL 01 PLAN

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

SCALE AT A1:

1:50 PROJECT NO:

DATE:

10

20

CHECKED:

DRAWN:

01.03.18 D.K & J.V DRAWING NO:

001 0

NO RT H

E.B REVISION:

4

A102 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


Notes: A200

DOOR TYPES

N

1

2

500

B

3

4600

4600

5

4600

WT 02 TO WRAP AROUND WT03 EXPOSING BRICK AND KEEPING BLOCKS INTERNAL

6

3927

3 A401

CW

3927

DT 04 CURTAIN WALL (SINGLE)

2

3

4

5

6

DN

1312

1057

1

12

UP

B

14

9

15

8

16

7

17

6

18

5

19

4

20

3

21

2

22

2

23

3

24

4

1

FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

DT 05 CURTAIN WALL (DOUBLE)

BALASTRADE TO BE INSTALLED ON HIGH POINT

DT 07 TOILET DOOR

DT 06 FIRE EXIT DOOR

10000

FT06

13

10

UP

05

CONCEALED MACHINE ROOM FOR VERTICAL WIND TUNNEL

WT05

9970

806

CORRIDOR 02

FT03

WALL TYPES

SLOPING FLOOR WITH LECTURE FURNITURES. UP

3000

11

DT 02 SINGLE DOOR

REFER TO A200 FOR CURTAIN WALL TYPE

FT06

WT03

DT 01 SLIDING DOOR

DT 03 DOUBLE DOOR

295

A

4

A302

FT03 GLASS PANELS TO BE LAYED OUT ACCORDING TO THE MANUFACTURER'S DETAIL. EDGE BEAMS TO JOIN ADJACENT WALLS

FIRE ESCAPE STAIRS 02

WT 01 (EXTERIOR) GLASS QUASI

1

WT02 (EXTERIOR) 270mm BRICK VENEER

5 6

WT03 (INTERIOR) 230 BLOCK VENEER

7 8 9

WT 04 (INTERIOR) 300mm CONCRETE

8000

11

LIFT SERVICE

8000

12

MAIN FEATURE STAIRS

TENSION WIRES TO SUPPORT MAIN FEATURE STAIRS AND HANDRAILS

13

UP

14 15

CONCEALED MACHINE ROOM FOR VERTICAL WIND TUNNEL

16 17 18

800

2700

19

3330

W

CW

20

1254

22

5880

C

9000

CORRIDOR 03

CORRIDOR 01

06

04

FT01

FT01

LECTURE ROOM FT06 1100

D01

FT 01 150mm 6 CORE HC SLAB FT 02 300mm 4 CORE HC SLAB

FT 03 150mm GLASS FLOOR FT 04 TOILET FLOOR FT 05 CAFE FLOOR

FLOOR HANGING FROM BEAM ABOVE AND SITTING ON TRUSES BELOW REFER TO DETAIL

WT06

FT 06 CLASSROOM FLOOR

400

WT08 6950

LIFT 02

MODULAR CURTAIN WALL REFER TO FACADE DETAIL

4

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV DESCRIPTION

DATE

PRELIMINARY

STATUS:

3000

1255

LIFT 01

200

3440

DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

WT07 D02 D06 8

WT05

7

6

5

4

3

2

1 24

9 10 11

FIRE ESCAPE STAIRS 01

12

951

TOILET MALE

23

01

22

UP 21

SERVICE SHAFT [MAIN]

FT04

FT04

TOILET FEMALE

03

6770

A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL

200

02

13 14 15 16 17 18 19 20

2500

RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL

S A201

MODULAR CURTAIN WALL TO HAVE OPAQUE GLASS

CLIENT:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION

FT04

300

951

RUBBISH CHUTE

TOILET DISABLED

D02

UP

SERVICE SHAFT [WORKSHOP]

D02

2500

UP

3000

4127

A200

5015

5000

WT07

1 : 50

E

5595

4614

VOID

WORKSHOP LEVELS DOUBLE HEIGHT

1

FLOOR TYPES

FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

07

3290

3000

4193

CURTAIN WALL WITHIN BRICK VENEER WALL REFER TO DETAILS

Level 2

WT08 (INTERIOR) 200mm FEATURE WALL

STEEL BEAM FROM FT03 TO JOIN INTO FT 05. REFER TO DETAIL

24

E

WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN

1000

23

D

WT 06 (INTERIOR) 100mm TIMBER STUD

21

WT04

UP

A201

WT 05 (INTERIOR) 200mm CONCRETE WALL

REFER TO A200 FOR CURTAIN WALL TYPE

A301

VERTICAL WIND TUNNEL TEST ROOM TO BE EXPOSED REFER TO MANUFACTURE'S DETAIL

7801

A

7807

10000

10

FT04 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

ARCHITECT:

DYNAMIC ARCHITECTS

ROOM LEGEND 1. TOILET DISABLED 2. TOILET FEMALE 3. TOILET MALE 4. CORRIDOR 01 5. CORRIDOR 02 6. CORRIDOR 03 7. LECTURE ROOM

TITLE:

LEVEL 02 PLAN

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

SCALE AT A1:

1:50 PROJECT NO:

DATE:

10

20

CHECKED:

DRAWN:

01.03.18 Author Checker DRAWING NO:

001 0

NO RT H

REVISION:

4

A103 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


Notes: DOOR TYPES

A200

DT 01 SLIDING DOOR

N

1

2

500

B

3

4600

4600

6

3927

DT 02 SINGLE DOOR

3927

DT 03 DOUBLE DOOR

4130

WT07

WT02

CW

REFER TO A200 FOR CURTAIN WALL TYPE

DT 04 CURTAIN WALL (SINGLE)

FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

295

A

5

4600

6000

WT02

4

A302

WT02

11

B C A304

2 A400

14

9

15

8

16

7

17

6

18

5

19

4

20

3

21

2

22

2

23

3

24

4

1

UP

FIRE ESCAPE STAIRS 02

DT 06 FIRE EXIT DOOR

CLASSROOM 01

10

DT 07 TOILET DOOR

07 FT06

FT03 GLASS PANELS TO BE LAYED OUT ACCORDING TO THE MANUFACTURER'S DETAIL. EDGE BEAMS TO JOIN ADJACENT WALLS

6408

WT03 400

A305

WT 02 TO WRAP D01 AROUND WT03 EXPOSING BRICK AND KEEPING BLOCKS INTERNAL

13

UP

3000

UP

D

12

DT 05 CURTAIN WALL (DOUBLE)

1

WALL TYPES

WT 01 (EXTERIOR) GLASS QUASI WT02 (EXTERIOR) 270mm BRICK VENEER

5

D06

6

WT03 (INTERIOR) 230 BLOCK VENEER

7

WT07

FT06

8 9

WT 04 (INTERIOR) 300mm CONCRETE

10

WT02

12

CLASSROOM 02 WT08

08

05

WORKSHOP

UP

OVERHEAD

15 16 17 18 19 20 21 22

CW

WT03

D01

A200

FT 01 150mm 6 CORE HC SLAB FT 02 300mm 4 CORE HC SLAB

FT 03 150mm GLASS FLOOR

FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

D03

FT 04 TOILET FLOOR

CORRIDOR 01

3000

4193

WT07

E

STEEL BEAM FROM FT03 TO JOIN INTO FT 05. REFER TO DETAIL

24

WORKSHOP TO BE EQUIPED WITH SPECIFIC MACHINERY. REFER TO FACULTY OFFICE

WT08 (INTERIOR) 200mm FEATURE WALL

FLOOR TYPES

23

400

C

LIGHT FITTING TO REFER CEILING PLAN AND MANUFACTURE'S DETAIL

13 14

W

WT 06 (INTERIOR) 100mm TIMBER STUD WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN

06 FT02

WT08

04

9470

FT 05 CAFE FLOOR

FT01 FT 06 CLASSROOM FLOOR

200 3700 1009

FT04

OVERHEAD

LIFT 01

LIFT 02

D07

D07

3168

03 3168

D

TOILET MALE

D02

WT04

6

5

4

3

9 10 11

2

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV DESCRIPTION

PRELIMINARY

STATUS:

MODULAR CURTAIN WALL REFER TO FACADE DETAIL

DATE

FIRE ESCAPE STAIRS 01

22 21

RUBBISH CHUTE

01

D07

D07

D07

D07

A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL

RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL

MODULAR CURTAIN WALL TO HAVE OPAQUE GLASS

CLIENT:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION

FT04

300

SERVICE SHAFT [WORKSHOP]

UP

SERVICE SHAFT [MAIN]

UP

WT05

TOILET DISABLED

23

13 14 15 16 17 18 19 20

E

FT04

02

Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

1

12

951

17/04/18

100

TOILET FEMALE

2500

7

24

1 : 50

12/05/18

Mid Sem Presentation

DYNAMIC ARCHITECTS

D02

UP

3000

4127

WT07 8

1

Final Package

3

D02

D06

Level 3

4

WT06

WT04

UP

A201

WT 05 (INTERIOR) 200mm CONCRETE WALL

FT06

FT03

CURTAIN WALL WITHIN BRICK VENEER WALL REFER TO DETAILS

TENSION WIRES TO SUPPORT MAIN FEATURE STAIRS AND HANDRAILS

8260

REFER TO A200 FOR CURTAIN WALL TYPE

D05

CORRIDOR 02

7407

7807

LIFT SERVICE

MAIN FEATURE STAIRS

7776

A A301

200

11

FT04 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

ARCHITECT:

DYNAMIC ARCHITECTS TITLE:

LEVEL 03 PLAN

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

S A201

ROOM LEGEND 1. TOILET DISABLED 2. TOILET FEMALE 3. TOILET MALE 4. CORRIDOR 01 5. CORRIDOR 02 6. WORKSHOP 7. CLASSROOM 01 8. CLASSROOM 02

SCALE AT A1:

1:50 PROJECT NO:

DATE:

10

20

CHECKED:

DRAWN:

01.03.18 Author Checker DRAWING NO:

001 0

NO RT H

REVISION:

4

A104 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


Notes: DOOR TYPES

A200

FT03 GLASS PANELS TO BE LAYED OUT ACCORDING TO THE MANUFACTURER'S DETAIL. EDGE BEAMS TO JOIN ADJACENT WALLS

N

1

2

500

4600

4

A302

4600

5

4600

6

3927

WT07

WT02

CW

3927

941

DT 02 SINGLE DOOR DT 03 DOUBLE DOOR

FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

REFER TO A200 FOR CURTAIN WALL TYPE

DT 04 CURTAIN WALL (SINGLE) DT 05 CURTAIN WALL (DOUBLE)

295

12

UP

11

13

WT04 TO CONNECT INTO ADJACENT MULLION

D04

14

A305

9

15

8

16

7

17

6

18

5

19

4

20

3

21

2

22

2

23

3

24

4

C A304

1

UP

DT 07 TOILET DOOR

D04 WT07

2000

WT07

UP

3000

10

D04

FT06

08

D

B

DT 06 FIRE EXIT DOOR

SEMINAR ROOMS

WT07

WALL TYPES

SEMINAR ROOMS'S WALL ATTACHED TO FLOOR ABOVE. REFER TO CEILING PLAN

5833

WT02

2051

A

B

3

DT 01 SLIDING DOOR

1

WT 01 (EXTERIOR) GLASS QUASI WT02 (EXTERIOR) 270mm BRICK VENEER

5

FIRE ESCAPE STAIRS 02

WT03 (INTERIOR) 230 BLOCK VENEER

6

2000

7 8

WT 04 (INTERIOR) 300mm CONCRETE

9 10 11

TENSION WIRES TO SUPPORT MAIN FEATURE STAIRS AND HANDRAILS

12

CLASSROOM 04 A

2000

A301

7807

LIFT SERVICE

CORRIDOR 02

FT03

WT02

WT08

MAIN FEATURE STAIRS

05

UP

WT05

07

WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN

LIGHT FITTING TO REFER CEILING PLAN AND MANUFACTURE'S DETAIL

13

2000

15

A404

WT 06 (INTERIOR) 100mm TIMBER STUD

FT06

14

2

WT 05 (INTERIOR) 200mm CONCRETE WALL

WT08 (INTERIOR) 200mm FEATURE WALL

16 17

FLOOR TYPES

18

W

7776

19 20

WT08

21

WT04

22 23 24

CORRIDOR 03 06

CURTAIN WALL WITHIN BRICK VENEER WALL REFER TO DETAILS

FLOOR HANGING FROM BEAM ABOVE AND SITTING ON TRUSES BELOW REFER TO DETAIL

FT01

CW

D03

CORRIDOR 01

2000

4193

2000

C

REFER TO A200 FOR CURTAIN WALL TYPE

A201

WT08

04 FT01

WT07 VOID

D02

1625

WORKSHOP LEVELS DOUBLE HEIGHT

D

WT06 LIFT 01

LIFT 02

UP

3000

4127

WT05

7

6

5

4

3

2

FT 04 TOILET FLOOR FT 05 CAFE FLOOR

FT 06 CLASSROOM FLOOR

4

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV DESCRIPTION

D07

DATE

PRELIMINARY

STATUS:

DYNAMIC ARCHITECTS

9

FIRE ESCAPE STAIRS 01

D07

23 22 21

UP

13 14 15 16 17 18 19 20

RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL

UP

RUBBISH CHUTE

S A201

UP

SERVICE SHAFT [MAIN]

Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

TOILET FEMALE

D02

1

12

951

D07

02

24

11

1 : 50

FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

FT04

10

1

FT 03 150mm GLASS FLOOR

D02

WT05

Level 4

FT 02 300mm 4 CORE HC SLAB

MODULAR CURTAIN WALL REFER TO FACADE DETAIL

D02

A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL

STEEL BEAM FROM FT03 TO JOIN INTO FT 05. REFER TO DETAIL

WT06

8

SERVICE SHAFT [WORKSHOP]

FT 01 150mm 6 CORE HC SLAB

FT04

WT04

WT07

E

A200

TOILET MALE 03

WT04 TO CONNECT INTO CORE WALL

E

TOILET DISABLED 01 FT04

D07

D07

D07

D07

MODULAR CURTAIN WALL TO HAVE OPAQUE GLASS

CLIENT:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION

FT04 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

ARCHITECT:

DYNAMIC ARCHITECTS

ROOM LEGEND 1. TOILET DISABLED 2. TOILET FEMALE 3. TOILET MALE 4. CORRIDOR 01 5. CORRIDOR 02 6. CORRIDOR 03 7. CLASSROOM 04 8. SEMINAR ROOMS

TITLE:

LEVEL 04 PLAN

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

SCALE AT A1:

1:50 PROJECT NO:

DATE:

10

20

CHECKED:

DRAWN:

01.03.18 Author Checker DRAWING NO:

001 0

NO RT H

REVISION:

4

A105 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


Notes: DOOR TYPES

A200 N

1

2

500

3

4600 3000

DT 01 SLIDING DOOR

4600

2

B

A402

A302

4

5

4600

6000

3927

1200

CW

3927

DT 02 SINGLE DOOR DT 03 DOUBLE DOOR

941

REFER TO A200 FOR CURTAIN WALL TYPE

DT 04 CURTAIN WALL (SINGLE)

FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

295

A

6

DT 05 CURTAIN WALL (DOUBLE) DT 06 FIRE EXIT DOOR

STUDENT LOUNGE 12

DT01

10

14

A305

9

15

8

16

7

17

6

18

5

19

4

20

1

3

21

A402

2

22

3000

3000

D

B

1

UP

FT06

DT 07 TOILET DOOR

WALL TYPES

WT03

WT 01 (EXTERIOR) GLASS QUASI

1 2

23

3

CORRIDOR 02

24

FIRE ESCAPE STAIRS 02

D05

3441

08

13

UP

UP

11

4 5

05

D06

6

FT03

WT02 (EXTERIOR) 270mm BRICK VENEER

WT08

WT08

CLASSROOM 06

WT03 (INTERIOR) 230 BLOCK VENEER

7

07 FT06

8 9

WT 04 (INTERIOR) 300mm CONCRETE

10 11 12

MAIN FEATURE STAIRS

8 A

A403

A301

6810

7807

LIFT SERVICE

TENSION WIRES TO SUPPORT MAIN FEATURE STAIRS AND HANDRAILS

WT 06 (INTERIOR) 100mm TIMBER STUD

WT07 UP

13

WORKSHOP

FT02 W

OVERHEAD

06

14 15 16 17 18 19

WT02

20

WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN

10743

REFER TO A200 FOR CURTAIN WALL TYPE

3 A402

A201

WT 05 (INTERIOR) 200mm CONCRETE WALL

FLOOR TYPES

E

CW

21

WT08 (INTERIOR) 200mm FEATURE WALL

A200

FT 01 150mm 6 CORE HC SLAB

22 23

C

FT 02 300mm 4 CORE HC SLAB

24

WT03 7

6

A403

A403

D03

CORRIDOR 01

3000

4193

WT07

04

DT01

FT 03 150mm GLASS FLOOR

FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

FT 04 TOILET FLOOR

WT08

FT 05 CAFE FLOOR

FT01

7100

FT 06 CLASSROOM FLOOR

WT02

D02

D LIFT 01

LIFT 02 3700

D07

UP 7

6

5

4

3

2

D07

1

UP

10 11

WT02

FIRE ESCAPE STAIRS 01

23

21

12 13 14 15 16 17 18 19 20

SERVICE SHAFT [WORKSHOP]

RUBBISH CHUTE

UP

SERVICE SHAFT [MAIN]

D07

D07

D07

A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL

1

Level 5 1 : 50

RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL

S A201

22/03/18

1

Project Set Up

03/03/18 DATE

PRELIMINARY

Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

D07

CLIENT:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION

01 FT04 300

WT04

UP

951

E

TOILET DISABLED

22

Preliminary Design

FT04 TOILET FLOOR TO BE WATERPROOFED AND SLOPED FOR DRAINAGE

02

24 9

2

DYNAMIC ARCHITECTS

FT04 TOILET FEMALE

D06 8

17/04/18

STATUS:

D02

WT05

12/05/18

Mid Sem Presentation

REV DESCRIPTION

D07

D02

WT04

Final Package

3

5768

3000

WORKSHOP TO BE EQUIPED WITH SPECIFIC MACHINERY. REFER TO FACULTY OFFICE

3168

03

OVERHEAD

4127

FT04 TOILET MALE

4

FT04 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

ARCHITECT:

DYNAMIC ARCHITECTS

ROOM LEGEND 1. TOILET DISABLED 2. TOILET FEMALE 3. TOILET MALE 4. CORRIDOR 01 5. CORRIDOR 02 6. WORKSHOP 7. LECTURE ROOM 8. STUDENT LOUNGE

TITLE:

LEVEL 05 PLAN

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

SCALE AT A1:

1:50 PROJECT NO:

DATE:

10

20

CHECKED:

DRAWN:

01.03.18 Author Checker DRAWING NO:

001 0

NO RT H

REVISION:

4

A106 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


Notes: DOOR TYPES

A200 DT 01 SLIDING DOOR

N

1

2

500

B

3

4600

4600

3000

4

A302

5

4600

6000

3927

1200

CW

3927

DT 02 SINGLE DOOR DT 03 DOUBLE DOOR

941

DT 04 CURTAIN WALL (SINGLE)

REFER TO A200 FOR CURTAIN WALL TYPE

2051

295

12

3000

13

10

14

9

15

8

16

7

17

6

18

5

19

4

20

3

21

2

22

1

UP

DT 06 FIRE EXIT DOOR

D04

DT 07 TOILET DOOR

OFFICE LOUNGE AREA WALL TYPES

2000

UP

11

B

DT 05 CURTAIN WALL (DOUBLE)

FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

UP

A

6

WT 01 (EXTERIOR) GLASS QUASI

1 2

CORRIDOR 02

23 24

4

05 FT03

FIRE ESCAPE STAIRS 02

WT02 (EXTERIOR) 270mm BRICK VENEER

3

5

WT03 (INTERIOR) 230 BLOCK VENEER

6

2000

7 8

WT 04 (INTERIOR) 300mm CONCRETE

9 10 11 12

8 A

MAIN FEATURE STAIRS

A403

2000

WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN

UP

13

OFFICE

14

2000

CORRIDOR 03 06

15

FT01

16

07

17

FT06

18 19

A201

W

20 21 22

WT08 (INTERIOR) 200mm FEATURE WALL

FLOOR TYPES

E

FT 01 150mm 6 CORE HC SLAB

A200

CW

FT 02 300mm 4 CORE HC SLAB

23

2000

400

C

WT 06 (INTERIOR) 100mm TIMBER STUD

LIFT SERVICE

REFER TO A200 FOR CURTAIN WALL TYPE

7807

A301

WT 05 (INTERIOR) 200mm CONCRETE WALL

TENSION WIRES TO SUPPORT MAIN FEATURE STAIRS AND HANDRAILS

24

7

6

A403

A403

FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

VOID 4193

CORRIDOR 01

FT 03 150mm GLASS FLOOR

D03

04 FT01

FT 04 TOILET FLOOR FT 05 CAFE FLOOR

OFFICE KITCHEN CORNER

3625

FT 06 CLASSROOM FLOOR

400

D02

D

FT04 TOILET MALE 03

LIFT 01

LIFT 02

D07

4

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV DESCRIPTION

D07

DATE

PRELIMINARY

STATUS:

3000 9500

DYNAMIC ARCHITECTS

D06 8

7

6

5

4

3

2

FT04 TOILET FEMALE

D02

UP

3000

4127

D02

FT04 TOILET FLOOR TO BE WATERPROOFED AND SLOPED FOR DRAINAGE

02

D07

1 24

9

UP

10 11

FIRE ESCAPE STAIRS 01

23

21

12 13 14 15 16 17 18 19 20

E 951

A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL

1

Level 6 1 : 50

RUBBISH CHUTE

RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL

UP

SERVICE SHAFT [WORKSHOP]

TOILET DISABLED

22

UP

SERVICE SHAFT [MAIN]

D07

D07

Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

D07

D07

CLIENT:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION

01 FT04

FT04 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

ARCHITECT:

DYNAMIC ARCHITECTS TITLE:

LEVEL 06 PLAN

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

S A201

ROOM LEGEND 1. TOILET DISABLED 2. TOILET FEMALE 3. TOILET MALE 4. CORRIDOR 01 5. CORRIDOR 02 6. CORRIDOR 03 7. OFFICE

SCALE AT A1:

1:50 PROJECT NO:

DATE:

10

20

CHECKED:

DRAWN:

01.03.18 Author Checker DRAWING NO:

001 0

NO RT H

REVISION:

4

A107 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


Notes: DOOR TYPES

A200

DT 01 SLIDING DOOR

N

1

2

500

B

3

4600

4600

WT02

4

A302

5

4600

3927

WT02

WT07

3927

DT 02 SINGLE DOOR

941

DT 03 DOUBLE DOOR

REFER TO A200 FOR CURTAIN WALL TYPE

DT 04 CURTAIN WALL (SINGLE) DT 05 CURTAIN WALL (DOUBLE)

FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

295

CW

A

6

REF. DW

DT 06 FIRE EXIT DOOR

WT02 12

B

14

9

15

8

16

7

17

6

18

5

19

4

20

3

21

2

22

1

UP

FIRE ESCAPE STAIRS 02

D01

DT 07 TOILET DOOR

2950

3000

WT07

13

10

KITCHEN

PHD RESERACH ROOM KITCHEN AREA

09

CORRIDOR 02

1712

WALL TYPES

FT06

05 UP

UP

11

WT 01 (EXTERIOR) GLASS QUASI

1

FT03

2

23

3

24

4

D03

WT02 (EXTERIOR) 270mm BRICK VENEER

5

D06

6

WT03 (INTERIOR) 230 BLOCK VENEER

7

WT02

8 9

WT 04 (INTERIOR) 300mm CONCRETE

10 11 12

7807

A301

LIFT SERVICE

PHD ROOM

8037

MAIN FEATURE STAIRS

A

07

WT 05 (INTERIOR) 200mm CONCRETE WALL

TENSION WIRES TO SUPPORT MAIN FEATURE STAIRS AND HANDRAILS

WT 06 (INTERIOR) 100mm TIMBER STUD

FT06

REFER TO A200 FOR CURTAIN WALL TYPE

WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN

UP

13

WORKSHOP 06 FT02 A201

W

OVERHEAD

14 15 16 17 18 19 20

D03

21 22

WT08 (INTERIOR) 200mm FEATURE WALL

FLOOR TYPES

E

A200

FT 01 150mm 6 CORE HC SLAB

CW FT 02 300mm 4 CORE HC SLAB

23

C

24

WT07

CORRIDOR 01

LOUNGE

04 FT01

08 FT01

FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

5820

4193

D01

FT 03 150mm GLASS FLOOR FT 04 TOILET FLOOR FT 05 CAFE FLOOR

PHD RESERACH ROOM WAITING AREA

FT 06 CLASSROOM FLOOR

WT02

D OVERHEAD

LIFT 01

LIFT 02

4

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV DESCRIPTION

PRELIMINARY

STATUS:

WT07

DYNAMIC ARCHITECTS

D02

D02

D02

D06 7

6

5

4

3

2

1

TOILET DISABLED

24 9

UP

10 11

WT02

22 21

13 14 15 16 17 18 19 20

951

SERVICE SHAFT [WORKSHOP]

RUBBISH CHUTE

RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL

UP

WT04

A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL

1 : 50

23

12

E

1

FIRE ESCAPE STAIRS 01

S A201

UP

SERVICE SHAFT [MAIN]

01 FT04

D07

D07 FT04

TOILET FEMALE 02

D07 FT04

TOILET MALE 03

3017

8

Level 7

Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

UP

4127

WORKSHOP TO BE EQUIPED WITH SPECIFIC MACHINERY. REFER TO FACULTY OFFICE

DATE

FT04 TOILET FLOOR TO BE WATERPROOFED AND SLOPED FOR DRAINAGE CLIENT:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION

FT04 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

ARCHITECT:

DYNAMIC ARCHITECTS

ROOM LEGEND 1. TOILET DISABLED 2. TOILET FEMALE 3. TOILET MALE 4. CORRIDOR 01 5. CORRIDOR 02 6. WORKSHOP 7. PHD ROOM 8. LOUNGE 9. KITCHEN

TITLE:

LEVEL 07 PLAN

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

SCALE AT A1:

1:50 PROJECT NO:

DATE:

10

20

CHECKED:

DRAWN:

01.03.18 Author Checker DRAWING NO:

001 0

NO RT H

REVISION:

4

A108 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


Notes: DOOR TYPES

A200 DT 01 SLIDING DOOR

N

1

2

500

B

3

4600

4

A302

4600

5

4600

3927

A

3927

DT 03 DOUBLE DOOR

941

DT 04 CURTAIN WALL (SINGLE)

REFER TO A200 FOR CURTAIN WALL TYPE

DT 05 CURTAIN WALL (DOUBLE)

FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

295

CW

DT 02 SINGLE DOOR

6

REF. DW

DT 06 FIRE EXIT DOOR

12

9

15

8

16

7

17

6

18

5

19

4

20

3

21

1

2

22

2

2

23

3

3

24

4

4

5

5

6

6

7

7

8

8

9

9

10

10

11

11

12

12

FIRE ESCAPE STAIRS 02

A301

7807

A

LIFT SERVICE

FT03

GLASS BOX TO BE SUPPORTED WITH TENSION WIRE ATTACHED TO FLOOR ABOVE. REFER TO DETAIL

TENSION WIRE TO SUPPORT STAIRS AND ACT AS HANDRAILS

966

MAIN FEATURE STAIRS

1

WT02 (EXTERIOR) 270mm BRICK VENEER WT03 (INTERIOR) 230 BLOCK VENEER

WT 04 (INTERIOR) 300mm CONCRETE

MAIN FEATURE STAIRS

WT 05 (INTERIOR) 200mm CONCRETE WALL

TENSION WIRES TO SUPPORT MAIN FEATURE STAIRS AND HANDRAILS

STUDENT LOUNGE

WT 06 (INTERIOR) 100mm TIMBER STUD

07 WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN

FT06

FT01 UP

UP

13

A201

WT 01 (EXTERIOR) GLASS QUASI

CORRIDOR 03 06

WALL TYPES

W

C

13

14

14

15

15

16

16

17

17

18

18

19

19

20

20

21

21

22

22

23

23

24

24

WT08 (INTERIOR) 200mm FEATURE WALL

16807

UP

1712

05

7807

1

CORRIDOR 02

UP

3000

14

WT07 TO ATTACH ADJACENT MULLION

STUDENT LOUNGE KITCHEN AREA TO BE WATERPROOFED AND SLOPED FOR DRAINAGE

D01

10

UP

B

DT 07 TOILET DOOR

13

REFER TO A200 FOR CURTAIN WALL TYPE

UP

11

FLOOR TYPES

E

FT 01 150mm 6 CORE HC SLAB

A200

FT 02 300mm 4 CORE HC SLAB

CW FT 03 150mm GLASS FLOOR

CORRIDOR 01 D01

4193

04

FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

DW REF.

VOID

FT 04 TOILET FLOOR FT 05 CAFE FLOOR

STUDENT LOUNGE FURNITURES TO REFER MANUFACTURE'S DETAIL

FT01

FT 06 CLASSROOM FLOOR

WORKSHOP LEVELS DOUBLE HEIGHT

D LIFT 01

4

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV DESCRIPTION

LIFT 02

PRELIMINARY DYNAMIC ARCHITECTS

D02

D02

D02

7

6

5

4

3

2

1

TOILET DISABLED

24 9

UP

10

FIRE ESCAPE STAIRS 01

11

23

21

12

RUBBISH CHUTE

UP

SERVICE SHAFT [MAIN]

D07

D07 FT04

02

TOILET MALE D07 FT04

03

S A201

1

Level 8 1 : 50

FT04 TOILET FLOOR TO BE WATERPROOFED AND SLOPED FOR DRAINAGE CLIENT:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION

FT04

300

951

13 14 15 16 17 18 19 20

UP

SERVICE CHUTE [WORKSHOP]

01

22

TOILET FEMALE

3017

D06 8

E

Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

UP

3000

4127

STATUS:

WT07 TO CONNECT INTO WT04 CORE

DATE

FT04 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

ARCHITECT:

DYNAMIC ARCHITECTS

ROOM LEGEND 1. TOILET DISABLED 2. TOILET FEMALE 3. TOILET MALE 4. CORRIDOR 01 5. CORRIDOR 02 6. CORRIDOR 03 7. STUDENT LOUNGE

TITLE:

LEVEL 08 PLAN

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

SCALE AT A1:

1:50 PROJECT NO:

DATE:

10

20

CHECKED:

DRAWN:

01.03.18 Author Checker DRAWING NO:

001 0

NO RT H

REVISION:

4

A109 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


Notes: DOOR TYPES

A200

DT 01 SLIDING DOOR

N

1

2

500

B

3

4600

4

A302

4600

5

4600

6

3927

3927

DT 02 SINGLE DOOR

941 DT 03 DOUBLE DOOR

CW

DT 05 CURTAIN WALL (DOUBLE)

FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

295

A

DT 04 CURTAIN WALL (SINGLE)

REFER TO A200 FOR CURTAIN WALL TYPE

DT 06 FIRE EXIT DOOR

12

9

15

8

16

7

17

6

18

5

19

4

20

3

21

1

2

22

2

22

23

3

21

24

4

20

5

19

6

18

7

17

8

16

9

15

10

14

11

13

1

UP

9770

FIRE ESCAPE STAIRS 02

2030

05 FT03

1900 WALL TYPES

24

D06

UP

3000

DT 07 TOILET DOOR

CORRIDOR 02

D01

14

UP

B

13

10

986

WT 01 (EXTERIOR) GLASS QUASI

23

WT02 (EXTERIOR) 270mm BRICK VENEER WT03 (INTERIOR) 230 BLOCK VENEER

WT 04 (INTERIOR) 300mm CONCRETE

DW

UP

11

12

7807

WORKSHOP

FT06 UP

OVERHEAD 1132

UP

400

C

11

14

10

15

9

16

8

17

7

18

6

19

5

20

4

21

3

22

2

23

DW

12 13

W

07

06 FT02

A201

STUDENT LOUNGE

WT07

WT 05 (INTERIOR) 200mm CONCRETE WALL

TENSION WIRES TO SUPPORT MAIN FEATURE STAIRS AND HANDRAILS

REFER TO A200 FOR CURTAIN WALL TYPE

A301

LIFT SERVICE

MAIN FEATURE STAIRS

8207

A

MAIN FEATURE STAIRS

7807

WT07

WT 06 (INTERIOR) 100mm TIMBER STUD WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN

WT08 (INTERIOR) 200mm FEATURE WALL

FLOOR TYPES

CW

E

2000

A200

STUDENT LOUNGE KITCHEN AREA TO BE WATERPROOFED AND SLOPED FOR DRAINAGE

FT 01 150mm 6 CORE HC SLAB FT 02 300mm 4 CORE HC SLAB

1

UP

24

FT 03 150mm GLASS FLOOR

FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

CORRIDOR 01 04

FT 04 TOILET FLOOR

3793

4193

D01 FT 05 CAFE FLOOR

WT04 FT 06 CLASSROOM FLOOR

400

WT03

D

OVERHEAD

LIFT 01

WIRES TO BE USED AS SPACE DIVIDER

LIFT 02

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV DESCRIPTION

DATE

PRELIMINARY

STATUS:

WT06

WT04

4

3426

D02

8

WT05

7

6

5

4

3

2

1

UP

11

FIRE ESCAPE STAIRS 01

23 22 21

12

951

WT04

1 : 50

SERVICE SHAFT [WORKSHOP]

RUBBISH CHUTE

RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL

UP

1451

13 14 15 16 17 18 19 20

A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL

1

TOILET DISABLED

24 9 10

Level 9

D02

D06

WT04

E

D02

Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

UP

4127

DYNAMIC ARCHITECTS

UP

SERVICE SHAFT [MAIN]

01

D07

D07 FT04

TOILET FEMALE 02

D07

TOILET MALE

FT04

03

FT04 TOILET FLOOR TO BE WATERPROOFED AND SLOPED FOR DRAINAGE CLIENT:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION

FT04

FT04 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

ARCHITECT:

DYNAMIC ARCHITECTS

S A201

ROOM LEGEND 1. TOILET DISABLED 2. TOILET FEMALE 3. TOILET MALE 4. CORRIDOR 01 5. CORRIDOR 02 6. WORKSHOP 7. STUDENT LOUNGE

TITLE:

LEVEL 09 PLAN

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

SCALE AT A1:

1:50 PROJECT NO:

DATE:

10

20

CHECKED:

DRAWN:

01.03.18 Author Checker DRAWING NO:

001 0

NO RT H

REVISION:

4

A110 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


Notes: DOOR TYPES

A200

FT03 GLASS PANELS TO BE LAYED OUT ACCORDING TO THE MANUFACTURER'S DETAIL. EDGE BEAMS TO JOIN ADJACENT WALLS

N

1

2

518

4600

5

4600

3927

WT02

WT07

6 3927

DT 03 DOUBLE DOOR DT 04 CURTAIN WALL (SINGLE)

REFER TO A200 FOR CURTAIN WALL TYPE

CW

250

DT 06 FIRE EXIT DOOR

WT07 DT 07 TOILET DOOR

2367

3000

2825

1300

DT 05 CURTAIN WALL (DOUBLE)

FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

D01 CORRIDOR 02

FT03 GLASS PANELS TO BE LAYED OUT ACCORDING TO THE MANUFACTURER'S DETAIL. EDGE BEAMS TO JOIN ADJACENT WALLS

WT03

24

400

2795

232

05

WT07

UP

B

DT 02 SINGLE DOOR

941

585

535

4

A302

4600

WT02

A

B

3

DT 01 SLIDING DOOR

23

WALL TYPES

WT 01 (EXTERIOR) GLASS QUASI

22

WT02 (EXTERIOR) 270mm BRICK VENEER

21

2376

20

WT07

19

WT03 (INTERIOR) 230 BLOCK VENEER

17

ROOFTOP GLASS PANELS TO BE WATERPROOFED REFER TO ROOF PLAN

12

UP

11

CW

9 8 7 6

STEEL BEAMS AS RAFTERS

W

5

WT07

4 3

WT02

232

1

400

VOID

2795

WT03

04

3310

3110

D01

FT01

WT07

E

FLOOR TYPES

FT 01 150mm 6 CORE HC SLAB

A200

FT 02 300mm 4 CORE HC SLAB

FT 03 150mm GLASS FLOOR

FT01 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE

FT 04 TOILET FLOOR FT 05 CAFE FLOOR

WATER TO FLOW ONTO EXTERIOR SIDE OF WT01 THEN DRIP DOWN

232

1300

4193

CORRIDOR 01

WT08 (INTERIOR) 200mm FEATURE WALL

ROOFTOP GARDEN PLANTING TO REFER LANDSCAPE ARCHITECT'S PLAN

STEEL BEAM FROM FT03 TO JOIN INTO FT 05. REFER TO DETAIL

2376

C

2

WT 06 (INTERIOR) 100mm TIMBER STUD WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN

10

WT07

WT 05 (INTERIOR) 200mm CONCRETE WALL

FT01

2376

1300

FT01

07

232

747

06

ROOFTOP GARDEN

WT 04 (INTERIOR) 300mm CONCRETE

TENSION WIRES TO SUPPORT MAIN FEATURE STAIRS AND HANDRAILS

REFER TO A200 FOR CURTAIN WALL TYPE

WT07

2376

MAIN FEATURE STAIRS

CORRIDOR 03

A201

8194

13

7407

14

7407

1300

7807

232

15

A A301

WATER TO FLOW ONTO EXTERIOR SIDE OF WT01 THEN DRIP DOWN

16

OVERHEAD

WT07

747

1300

18

FT 06 CLASSROOM FLOOR

WT03

1509

LIFT 01

LIFT 02 WT04

2815

250

2738

WT05

7

6

5

4

3

2

1

9

UP

10

2347

11

FIRE ESCAPE STAIRS 01

23 22 21

12 13 14 15 16 17 18 19 20

951

RUBBISH CHUTE

UP

SERVICE SHAFT [WORKSHOP]

232

12/05/18

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

UP

SERVICE SHAFT [MAIN]

01 FT04 WT05

PRELIMINARY

STATUS:

MODULAR CURTAIN WALL REFER TO FACADE DETAIL

DATE

D02

TOILET FEMALE 02

TOILET DISABLED

24

WT07

2756

D02

WT05

UP 8

Final Package

3

DYNAMIC ARCHITECTS

D06

E

241

D02 3000

1300

4127

WT07

OVERHEAD

WT06

814

1873

WT07

WORKSHOP LEVELS DOUBLE HEIGHT

4

REV DESCRIPTION

250

2795

D

PERGOLAR TO PROVIDE SHADE REFER TO ROOF PLAN

2367

WT07

D07

D07 FT04

D07 FT04

TOILET MALE 03

Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

FT04 TO ATTACH TO INNER SIDE OF WT01 FORMING SAWTOOTH SHAPE MODULAR CURTAIN WALL TO HAVE OPAQUE GLASS

CLIENT:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION

FT04 TOILET FLOOR TO BE WATERPROOFED AND SLOPED FOR DRAINAGE

ARCHITECT:

DYNAMIC ARCHITECTS A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL

1

Level 10 1 : 50

RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL

S A201

ROOM LEGEND 1. TOILET DISABLED 2. TOILET FEMALE 3. TOILET MALE 4. CORRIDOR 01 5. CORRIDOR 02 6. CORRIDOR 03 7. ROOFTOP GARDEN

TITLE:

ROOFTOP GARDEN PLAN

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

SCALE AT A1:

1:50 PROJECT NO:

DATE:

10

20

CHECKED:

DRAWN:

01.03.18 Author Checker DRAWING NO:

001 0

NO RT H

REVISION:

4

A111 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


Notes: HVAC UNIT HV01: JOHNSON CONTROLS SERIES 100 FORM 100.50‐EG10 (516) HV02: JOHNSON CONTROLS SERIES 40 355278‐JTG‐L‐0113 DOOR TYPES

A200 N

1

2

518

4600

510

B

3

A302

4600 6211

DT 01 SLIDING DOOR

4

5

4600

241 500

3927

6392

941

DT 03 DOUBLE DOOR

REFER TO A200 FOR CURTAIN WALL TYPE

DT 04 CURTAIN WALL (SINGLE) DT 05 CURTAIN WALL (DOUBLE)

WT02

WT07

WT02

DT 06 FIRE EXIT DOOR

WT07

3000

1300

585

535

3927

DT 02 SINGLE DOOR

500

CW

A

6

DT 07 TOILET DOOR

HVAC UNIT FOR WESTERN TOWER

HV01 2795

WALL TYPES

B

HV02

WT02

WT07

WT02

HV02

WT07

1818

WT02

WT07

WT07

WT02

WT07

2795

HV02

WT 05 (INTERIOR) 200mm CONCRETE WALL WT 06 (INTERIOR) 100mm TIMBER STUD

CW

REFER TO A200 FOR CURTAIN WALL TYPE

1300

WT02

SKY LIGHTS TO BE LIFTED FROMROOF. REFER TO ELEVATION

ROOFTOP GARDEN BELOW

1818

15635

1300

WT02

747

7807

WT03 (INTERIOR) 230 BLOCK VENEER

HV02

W

C

WT02 (EXTERIOR) 270mm BRICK VENEER

ROOFTOP GLASS PANELS TO BE WATERPROOFED

WT07 3636

HV01

A201

WT 01 (EXTERIOR) GLASS QUASI

WT 04 (INTERIOR) 300mm CONCRETE

747

1300

ROOFTOP GARDEN PLANTING TO REFER LANDSCAPE ARCHITECT'S PLAN

A A301

HV02

WT07 (INTERIOR/EXTERIOR) 150mm FULL CURTAIN

WT08 (INTERIOR) 200mm FEATURE WALL

FLOOR TYPES

E

A200 FT 01 150mm 6 CORE HC SLAB

STEEL BEAMS HOLDING THE SHADES CLOTHS UP

HV02

FT 02 300mm 4 CORE HC SLAB

HVAC UNIT FOR EASTERN TOWER HV02

FT 03 150mm GLASS FLOOR

HV02

1300

4193

FT 04 TOILET FLOOR

WT02

WT07

WT02

WT07

FT 05 CAFE FLOOR

STEEL PERGOLAR WITH SHADE CLOTHS

HV01 HV02

2795

D

FT 06 CLASSROOM FLOOR

HV02

5977

4

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV DESCRIPTION

PRELIMINARY

STATUS:

MODULAR CURTAIN WALL REFER TO FACADE DETAIL

DATE

1300

4127

DYNAMIC ARCHITECTS

WT02

WT07

Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

WT02 HV01

HV01 HV02 3317

HV02

CLIENT:

2347

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION

951

E

ARCHITECT:

DYNAMIC ARCHITECTS 6962

15710 TITLE:

ROOF PLAN

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

S A201

1

SCALE AT A1:

ROOF

1:50 PROJECT NO:

1 : 50

DATE:

10

20

CHECKED:

DRAWN:

01.03.18 Author Checker DRAWING NO:

001 0

NO RT H

REVISION:

4

A112 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


Notes: CEILING SCHEDULE CT01: [PLASTER PANELS] ULTIMA+OP BY 'ARMSTRONG' CT02: [TIMBER PANELS] LAUDER LINEA 4.2.1 BY 'LAUDESCHER' CT03: [TOILET CEILING] MINERAL FIBER PLANKS BY 'ARMSTRONG' CT04: [CAFE CEILING] INNOCEIL BY 'INNOWOOD' CT05: [EXPOSED FLOOR SLAB ABOVE] CT06: [CUSTOM TIMBER TRUSS] BY 'VERMONT TIMBER WORKS'

A200 N

1

2

500

4600

WT02

4

A302

4600

5

4600

3927

WT02

WT07

6

CW

3927

*CEILING PANELS INCORPORATE ACOUSTIC FOAM AS PER MANUFACTURERS' SPECIFICATIONS

941

LIGHT SCHEDULE LT01: [RECESSED LIGHT] 12w DL5530 316 LED DOWNLIGHT LT02: [PENDANT LIGHT] JET150 LED PENDANT LIGHT ‐BLACK CHROME LT03: [SCONCE LAMP] LUPE WALL SCONCE BY WEPLIGHT LT04: [WALL LAMP] BESTLITE BL7 WALL LAMP LT05: [TROFFER LIGHT] UNILUX PROFILE SURFACE MOUNT LT06: [LOUVER LIGHT] OFFICE PLUS LB LED P/T

REFER TO A200 FOR CURTAIN WALL TYPE

295

WT02

A

B

3

WT02

FIRE ESCAPE STAIRS 02

3000

LT02

LT02 LT04

WT07

600x1200mm TILED CEILING IN WORKSHOP TO HAVE PENDANT LIGHT HANGING FROM SLAB ABOVE

B

LT02

WT02

LT02

LT03

VOID ABOVE TO LVL 2

LOBBY 01

FT03

WT02

LT02

LT02

MAIN FEATURE STAIRS

A

7807

A301

LIFT SERVICE

LT02 WORKSHOP EXHIBITION

LT02

LT02

LT02 CW

LT02

REFER TO A200 FOR CURTAIN WALL TYPE

02 CT01

WT02

3650 mm

LT02 A201

LT02

LT02

W

LT02

LT02

LT03

LT02

C LT05

LT05

LT05

CT04

CAFE SERVICE

3950 mm

05

LT02

WT07

PENDANT LIGHTING TO BE PLACED BETWEEN TIMBER FEATURE CEILING PANELS

E

A200

75MMX350MM GLULAM CEILING BEAMS

LT02

LT02

CT02

4193

4000 mm

LT05 LT02

LT02

LT05

LT05 LT04

LT02

LT04

600x600mm CUSTOM MADE TIMBER PANELS WITH TROFFER LIGHTS IN CAVITY SPACE

CAFE KITCHEN LT02

LT05

06

CAFE COOL ROOM

D

CT01

07 LT02

LT02

LT02

LIFT 01

LIFT 02

3500 mm

LT04

3500 mm 4127

08

LT04

LT02

CT01 3650 mm

951

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18 DATE

PRELIMINARY

600x600mm TILED CEILING IN CAFE KITCHEN EQUPPED WITH TROFFER LIGHTS

DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

CT03

LT03

E

12/05/18

Mid Sem Presentation

STATUS:

LT04

REFUSE STORAGE

WT02

Final Package

3

REV DESCRIPTION

CT01

LT02

4

LT02

LT02

3500 mm

Disabled Toilet

FIRE ESCAPE STAIRS 01 SERVICE SHAFT [WORKSHOP]

04 TOILET UNISEX

SERVICE SHAFT [MAIN]

WT04

TOILET TO HAVE RECESSED CEILING WITH LIGHTS. REFER TO TYPICAL AMENITIES PLAN

CLIENT:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION

03 LT01

LT01

LT01

ARCHITECT:

DYNAMIC ARCHITECTS A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL

1

RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL

S

SERVICE SHAFT FOR OFFICE TOWER

WT04

A201

TITLE:

REFLECTED CEILING PLAN 01

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

SCALE AT A1:

GROUND FLOOR

1:50 PROJECT NO:

1 : 50

DATE:

10

20

CHECKED:

DRAWN:

01.03.18 Author Checker DRAWING NO:

001 0

NO RT H

REVISION:

4

A113 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


Notes: CEILING SCHEDULE CT01: [PLASTER PANELS] ULTIMA+OP BY 'ARMSTRONG' CT02: [TIMBER PANELS] LAUDER LINEA 4.2.1 BY 'LAUDESCHER' CT03: [TOILET CEILING] MINERAL FIBER PLANKS BY 'ARMSTRONG' CT04: [CAFE CEILING] INNOCEIL BY 'INNOWOOD' CT05: [EXPOSED FLOOR SLAB ABOVE] CT06: [CUSTOM TIMBER TRUSS] BY 'VERMONT TIMBER WORKS' CT07: [RAKED CEILING] TIMBER VENEER PANELS BY "INNOWOOD"

A200 N

1

2

500

B

3

4600

4600

3000

4

A302

5

4600

6000

6

3927

3927

*CEILING PANELS INCORPORATE ACOUSTIC FOAM AS PER MANUFACTURERS' SPECIFICATIONS

941

LIGHT SCHEDULE LT01: [RECESSED LIGHT] 12w DL5530 316 LED DOWNLIGHT LT02: [PENDANT LIGHT] JET150 LED PENDANT LIGHT ‐BLACK CHROME LT03: [SCONCE LAMP] LUPE WALL SCONCE BY WEPLIGHT LT04: [WALL LAMP] BESTLITE BL7 WALL LAMP LT05: [TROFFER LIGHT] UNILUX PROFILE SURFACE MOUNT LT06: [LOUVER LIGHT] OFFICE PLUS LB LED P/T

1200 815

WT02

REFER TO A200 FOR CURTAIN WALL TYPE

LT04 WT02

7900

1032

1170

295

575

CW

FIRE ESCAPE STAIRS 02

8638

LT04

3000

A

WT02

WT07

B

CONCEALED MACHINE ROOM FOR VERTICAL WIND TUNNEL

LT04 LT03

LT01

LT01

LT01

LT01

LT01

LT01

LT01

LT01

LT01

LT01

LT01

LT01

LT01

LT01

LT01

LT01

LT01

LT01

5875

3200

3050

WT07

LT04

950

CORRIDOR 02

300

05 FT03

3600

WT02

A

VERTICAL WIND TUNNEL TEST ROOM TO BE EXPOSED REFER TO DETAIL

MAIN FEATURE STAIRS

4000

7807

A301

LIFT SERVICE

MEETING ROOM 02

07

08

CONCEALED MACHINE ROOM FOR VERTICAL WIND TUNNEL

1332

LT01 CT07

LT01

LT04

LT01

LT01 CT07

LT01

4350 mm

4350 mm

400

7357

LT05

LT05

LT05

LT05

CORRIDOR 01 LT01

WORKSHOP

3000

LT05

06

LT05

LT05

LT05

LT05

CT02

04

LT01

LT05

LT05

4000 mm

LT05

LT05 MEETING ROOM 03

5000

4193

A200

LT03

VOID

WT07

7357

E

1778

C

LT01

09

LT01

LT01

LT01

WT02

LT01

CT05 4350 mm

LT01

LT01

LT01

2885

A201

W

3200

300

LT04

5139

MEETING ROOM 01

REFER TO A200 FOR CURTAIN WALL TYPE

CW

400

LT05

D

CT06

LIFT 02 LT05

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

LT05

PRELIMINARY DYNAMIC ARCHITECTS

LT05

Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

3000

WT07

DATE

LT05

LT05 3000

17/04/18

1300

LT05

3440

4000 mm

4000 mm

1664

FIRE ESCAPE STAIRS 01 SERVICE SHAFT [WORKSHOP]

RUBBISH CHUTE

WT02

SERVICE SHAFT [MAIN]

4000 mm

CT03

CT03

TOILET DISABLED

TOILET FEMALE

TOILET MALE

01

02

03

LT01

LT01

CT03

2500

4127

12/05/18

Mid Sem Presentation

STATUS:

4350 mm

951

Final Package

3

REV DESCRIPTION

LIFT 01

E

4

CLIENT:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:

LT01

DYNAMIC ARCHITECTS A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL

1

RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL

TITLE:

REFLECTED CEILING PLAN 02

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

S A201

SCALE AT A1:

Level 1

1:50 PROJECT NO:

1 : 50

DATE:

10

20

CHECKED:

DRAWN:

01.03.18 Author Checker DRAWING NO:

001 0

NO RT H

REVISION:

4

A114 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


Notes:

1

2

500

B

3

4600

CEILING SCHEDULE CT01: [PLASTER PANELS] ULTIMA+OP BY 'ARMSTRONG' CT02: [TIMBER PANELS] LAUDER LINEA 4.2.1 BY 'LAUDESCHER' CT03: [TOILET CEILING] MINERAL FIBER PLANKS BY 'ARMSTRONG' CT04: [CAFE CEILING] INNOCEIL BY 'INNOWOOD' CT05: [EXPOSED FLOOR SLAB ABOVE] CT06: [CUSTOM TIMBER TRUSS] BY 'VERMONT TIMBER WORKS'

4

A302

4600

5

4600

6

3927

3927

*CEILING PANELS INCORPORATE ACOUSTIC FOAM AS PER MANUFACTURERS' SPECIFICATIONS

941 LIGHT SCHEDULE LT01: [RECESSED LIGHT] 12w DL5530 316 LED DOWNLIGHT LT02: [PENDANT LIGHT] JET150 LED PENDANT LIGHT ‐BLACK CHROME LT03: [SCONCE LAMP] LUPE WALL SCONCE BY WEPLIGHT LT04: [WALL LAMP] BESTLITE BL7 WALL LAMP LT05: [TROFFER LIGHT] UNILUX PROFILE SURFACE MOUNT LT06: [LOUVER LIGHT] OFFICE PLUS LB LED P/T

6000

A

REFER TO A200 FOR CURTAIN WALL TYPE

295

CW

LT04 FIRE ESCAPE STAIRS 02

CORRIDOR 02

3000

05 LT04

D

LT01

LT01

LT01

LT01

LT01

LT01

FT03

LT01

5242

A305

LT01

600x1200mm TILED CEILING IN WORKSHOP TO HAVE PENDANT LIGHT HANGING FROM SLAB ABOVE

LT03

LT04

LT06

B

LT06

LT06

LT03 C A304

LT01

LT01

LT04 LT03

CLASSROOM 01

CT01

07

3600 mm

LT03 LT03

LT04

LT06

LT03

LT06

WALL LIGHT TO BE ATTACHED TO WT03 BLOCK VENEER

LT06

LT03 LT04 LT03 7807

A

LT01

A301

MAIN FEATURE STAIRS LT03

LT01

LIFT SERVICE

LT06

LT03 LT01

LT01

LT06

LT06

LT06

LT03

LT04

LT03 LT04

4350 mm

LT06

LT06

08

LT06

PENDANT LIGHT BETWEEN TIMBER TRUSS CEILING TO HANG FROM SLAB ABOVE

CT01

LT03 LT06

C

600x1200mm PANEL CEILING WITH RECESSED LIGHT IN CEILING CAVITY SPACE

CLASSROOM 02 LT06

CT06

LT06

LT03

5192

LT04

LT03

LT06

3600 mm

LT06

LT03 LT05

LT05

LT05 LT06

LT01

LT06

CORRIDOR 01

LT01

WORKSHOP

5242

3000

4193

04 LT05

LT05

06

CW

LT05

LT06

LT05

CT02

VOID ABOVE. WORKSHOP TO BE DOUBLE STORY HEIGHT

LT01

LT03

LT03

LT03

LT06 LT03

LT03

LT03

LT03

4000 mm

LT01

LT05

D

CT03

LT05

REFER TO A200 FOR CURTAIN WALL TYPE

VOID

600x600mm CUSTOM MADE TIMBER PANELS WITH TROFFER LIGHTS IN CAVITY SPACE

LT05 4000 mm

LIFT 01

4

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV DESCRIPTION

LIFT 02

PRELIMINARY

STATUS:

TOILET MALE LT05

LT05

LT05

FIRE ESCAPE STAIRS 01

951

Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

LT01

CT03

SERVICE SHAFT [WORKSHOP]

DYNAMIC ARCHITECTS

03

3000

3000

4127

3000

E

DATE

RUBBISH CHUTE

4000 mm

SERVICE SHAFT [MAIN]

TOILET DISABLED 01 LT01

CT03

TOILET FEMALE

4000 mm

02

TOILET TO HAVE RECESSED CEILING WITH LIGHTS. REFER TO TYPICAL AMENITIES PLAN

CLIENT:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:

LT01

DYNAMIC ARCHITECTS A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL

1

RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL

SERVICE SHAFT FOR OFFICE TOWER

TITLE:

REFLECTED CEILING PLAN 03

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

SCALE AT A1:

Level 3

1:50 PROJECT NO:

1 : 50

DATE:

10

20

CHECKED:

DRAWN:

01.03.18 Author Checker DRAWING NO:

001 0

NO RT H

REVISION:

4

A115 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


Notes: CEILING SCHEDULE CT01: [PLASTER PANELS] ULTIMA+OP BY 'ARMSTRONG' CT02: [TIMBER PANELS] LAUDER LINEA 4.2.1 BY 'LAUDESCHER' CT03: [TOILET CEILING] MINERAL FIBER PLANKS BY 'ARMSTRONG' CT04: [CAFE CEILING] INNOCEIL BY 'INNOWOOD' CT05: [EXPOSED FLOOR SLAB ABOVE] CT06: [CUSTOM TIMBER TRUSS] BY 'VERMONT TIMBER WORKS'

A200 N

1

2

500

4600

7

B

A403

A302

4600

4

5

4600

3927

WT02

WT07

6

CW

3927

*CEILING PANELS INCORPORATE ACOUSTIC FOAM AS PER MANUFACTURERS' SPECIFICATIONS LIGHT SCHEDULE LT01: [RECESSED LIGHT] 12w DL5530 316 LED DOWNLIGHT LT02: [PENDANT LIGHT] JET150 LED PENDANT LIGHT ‐BLACK CHROME LT03: [SCONCE LAMP] LUPE WALL SCONCE BY WEPLIGHT LT04: [WALL LAMP] BESTLITE BL7 WALL LAMP LT05: [TROFFER LIGHT] UNILUX PROFILE SURFACE MOUNT LT06: [LOUVER LIGHT] OFFICE PLUS LB LED P/T

941

REFER TO A200 FOR CURTAIN WALL TYPE

295

WT02

A

3

3000

WT02

FIRE ESCAPE STAIRS 02

LT02

LT02

LT02

LT02

LT02

D

WT07

A305

LT02

LT02

LT02

LT02

NO CEILING IN CORRIDOR 03. PENDANT LIGHT TO HANG FROM SLAB ABOVE

WT07

WT07 LT02

1

B

LT02

A402

SEMINAR ROOMS

C A304

LT02

08

LT02 LT02

CORRIDOR 02

CT05

05 WT07

WT05

NO CEILING IN MEETING ROOM. PENDANT LIGHT TO HANG FROM SLAB ABOVE

LT02

WT08

4350 mm

LT02

LT02

LT02

LT02

600x1200mm TILED CEILING IN WORKSHOP TO HAVE PENDANT LIGHT HANGING FROM SLAB ABOVE

LT02 8

7807

A

A403

LT02

A301

LIFT SERVICE

LT06

LT06

LT06

LT06

LT06

LT06

WT08 3 A402

CLASSROOM 04

VOID

CT05

LT02

3600 mm

LT06

4193

LT02 LT02

LT06

LT06

LT06

LT06

LT06

LT06

E

A200

LT02 LT02

WT07

LT06 CT01

06

C

LT06

LT02 CORRIDOR 03

3650 mm

W

07 LT06

4350 mm

CT03 A201

REFER TO A200 FOR CURTAIN WALL TYPE

LT02

LT02 WT02

CW

LT05

LT05

LT05

2

6

A402

A403

LT05

LT05

LT02

LT05

CT02

CORRIDOR 01

4000 mm

04

LT05

600x600mm CUSTOM MADE TIMBER PANELS WITH TROFFER LIGHTS IN CAVITY SPACE

WT08

LT02 WT02

LT05

D

TOILET MALE LT05

LT02

LIFT 01

LT02

LT05

03

4

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV DESCRIPTION

LIFT 02

DATE

PRELIMINARY

STATUS:

WT04 CT03

WT07

LT05

WT04

LT05

DYNAMIC ARCHITECTS

LT05

4127

4000 mm

Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

LT01

WT05 LT02

LT02

CT03

LT02 FIRE ESCAPE STAIRS 01

E

SERVICE SHAFT [WORKSHOP]

RUBBISH CHUTE WT05

WT02

4000 mm

SERVICE SHAFT [MAIN]

TOILET DISABLED

TOILET FEMALE

CT03

01

4000 mm

LT01

LT01

TOILET TO HAVE RECESSED CEILING WITH LIGHTS. REFER TO TYPICAL AMENITIES PLAN

CLIENT:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION

02

ARCHITECT:

DYNAMIC ARCHITECTS A/C AND APPLICABLE SERVICE PIPING TO BE PLACE WITHIN SERVICE SHAFT. REFER TO MANUFACTURER'S DETAIL

1

RUBBISH TO FALL INTO COMPRESSOR WHICH TRANSFERS INTO BINS REFER TO MANUFACTURER'S DETAIL

S

SERVICE SHAFT FOR OFFICE TOWER

WT04

A201

TITLE:

REFLECTED CEILING PLAN 04

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

SCALE AT A1:

Level 4

1:50 PROJECT NO:

1 : 50

DATE:

10

20

CHECKED:

DRAWN:

01.03.18 Author Checker DRAWING NO:

001 0

NO RT H

REVISION:

4

A116 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


E

1 : 100

4

3927

3

3927

4600

2 4600

ELEVATION EAST 1 : 100

E

1 4600

D 6342

500

1500

2595

B 1500 547 1500 547 1500

2595

A 1500 485

CW01 CURTAIN WALL MODULE TYPE1

ROOF

ROOF

49500

49500 CW02 CURTAIN WALL MODULE TYPE 2

3000

1300

WT02

C

2100

906

5

2100

6

CW08

CW05

CW01

WT02

CW01

CW10

Level 10

CW09

1500

CW01

7000

CW02

CW04

CW01

CW01

CW01

CW01

CW01

CW01

CW03 CURTAIN WALL MODULE TYPE 3

CW04 Level 10

45000

45000

CW01

CW03

CW04

CW03

CW01

2000

CW09

4500

WT07

CW06

CW05

CW01

CW04

CW01

CW08

CW09

CW03

CW01

CW04

CW01

CW01

CW05

CW03

CW04 CURTAIN WALL MODULE TYPE 4

CW10

Level 9

Level 9

40500

40500

CW01

CW02

CW11

CW04

CW03

CW01

CW01

CW01

CW01

CW02

CW05 CURTAIN WALL MODULE TYPE 5

CW06 CURTAIN WALL MODULE TYPE 6

CW04

7000

WT07

CW06

CW04

CW03

CW01

CW02

CW03

CW01

CW04

CW05

Level 8

Level 8

36000

36000

CW01

CW06

2000

CW07

CW09

CW03

CW03

CW01

CW01

CW01

CW01

CW01

CW08 CURTAIN WALL MODULE TYPE 8

Level 7

31500

31500

CW07

CW09

CW04

CW01

CW04

CW01

CW01

CW01

CW03

CW07 CURTAIN WALL MODULE TYPE 7

CW07

Level 7

CW01

CW09 CURTAIN WALL MODULE TYPE 9

CW01 CW10 CURTAIN WALL MODULE TYPE 10

7000

WT07 Level 6

Level 6

27000

27000 CW11 CURTAIN WALL MODULE TYPE 11

CW08

CW01

CW03

CW04

CW01

CW01

CW02

CW11

CW03

CW01

CW01

CW01

CW01

CW01

CW01

CW06 REFER TO DRAWING A600 FOR ASSEMBLY AND PANEL INSERT TYPE

2000

WT02

CW01

CW08

CW04

CW03

CW01

Level 5

Level 5

22500

22500

CW01

CW08

CW09

CW04

CW09

CW03

CW01

CW01

CW05

CW01

ANY GLAZED PANELS THAT FALL ON AND BETWEEN GRIDS E AND D BACK COATED IN SOLID SILK SCREEN

CW02

7000

WT07

CW07

CW04

CW03

CW04

CW01

Level 4

Level 4

18000

18000

CW01

CW06

CW11

CW04

CW01

CW04

CW01

CW01

CW01

CW10

CW03

4

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV DESCRIPTION

2000

CW08

CW06

CW08

CW03

CW01

Level 3

Level 3

13500

13500

CW01

CW09

CW11

CW01

CW03

CW04

CW01

CW01

CW01

CW01

DATE

PRELIMINARY

STATUS:

DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

CW04

7000

WT07 Level 2

Level 2

9000

9000

CLIENT:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:

CW05

CW01

CW03

CW01

CW02

CW05

CW01

CW01

WT07

CW05

CW01

CW01

CW01

CW01

CW01

CW04

CW11

DYNAMIC ARCHITECTS

Level 1

Level 1

4500

2500

CW04

WT01

CW02

D03 GROUND FLOOR 0

CW09

CW04

CW03

CW04

CW01

CW01

CW01

890 890 890 890 940

CW03

1000 1000

CW02

1000

N

ELEVATION NORTH

Notes:

TITLE:

ELEVATIONS ‐ NORTH & EAST

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

4500

SCALE AT A1:

1:100 PROJECT NO:

GROUND FLOOR

DATE:

01.03.18 D.K & J.V DRAWING NO:

001

0 0

10

20

CHECKED:

DRAWN:

E.B REVISION:

4

A200 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


W

1 : 100

2000

6944

WT02

3 400

4

6592

HV01

5 8718

HV02

A

6

B

485 1500

406

HV01 ROOF

Notes:

1 : 100

2100

2

ELEVATION WEST 2595

C 1500 547 1500 547 1500

HV01

HV02

HV01

2595

D 1500

6342

HV01

HV02 HV02

E

HV01 ROOF

69

1

49500

49500 4034

Level 10

CW08

Level 9 40500

WT07

WT07

WT07

WT07

WT07

45000

WT07

WT07

WT07

Level 9 40500

3500

CW02

WT07

Level 10

2600

45000

WT02

901 397

CW10

1000 1000

4600

WT02

WT07

WT07

WT07 Level 8

36000

36000 3500

Level 8

CW06

31500

31500

3500

CW07

Level 7

2000

Level 7

WT07

WT07

WT07

Level 6

Level 6

27000

27000 3500

WT04

CW02 WT02 Level 5 22500

22500

3500

CW08

Level 5

2000

45000

WT07

WT07

WT07 Level 4

18000

18000 3500

Level 4

CW06

4

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV DESCRIPTION

13500

DATE

PRELIMINARY

STATUS:

1000 1000

Level 3

Level 3 13500

DYNAMIC ARCHITECTS

3

Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

A400

CW09 WT07

9000

WT07

WT07 Level 2

7000

Level 2

CLIENT:

9000

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION

CW02

ARCHITECT:

2650

4500

CW02

GROUND FLOOR 0

DYNAMIC ARCHITECTS

850 1000

Level 1

1000

S

ELEVATION SOUTH

Level 1 4500

WT07

TITLE:

ELEVATIONS ‐ SOUTH & WEST

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

WT07 D06

SCALE AT A1:

1:100

GROUND FLOOR

PROJECT NO:

0

DATE:

01.03.18 Author Checker DRAWING NO:

001 0

10

20

CHECKED:

DRAWN:

REVISION:

4

A201 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


SERVICE ZONE TRANSPARENT ZONE

-4000

BASEMENT

0

GROUND FLOOR

Level 1

4500

EXHIBITION ROOM

VERTICAL WIND TUNNEL 9000

Level 2

13500

Level 3

18000

Level 4

VOID AREA

HANGING BOX 22500

Level 5

27000

Level 6

SERVICE LIFT

MAIN FEATURE STAIRS 31500

Level 7

WORKSHOP DOUBLE HEIGHT 36000

Level 8

40500

Level 9

45000

Level 10

49500

ROOF

1

LOUNGE ZONE

2 3

OFFICE ZONE

4

CLASSROOM ZONE

5 0

10

20

30

Notes:

40

4

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV

STATUS:

50

60

70

80

90

100

DESCRIPTION

PRELIMINARY

DATE

DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

CLIENT:

SITE:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:

DYNAMIC ARCHITECTS

TITLE:

WORKSHOP ZONE

1 : 100

1

ZONE SECTION

BASEMENT WORKSHOP

CAFE

MEETING ROOM

LECTURE ROOM

CLASSROOM

OFFICE

STUDENT LOUNGE

ROOFTOP GARDEN

6 ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS.CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.

81/89 BOUVERIE ST, CARLTON VIC 3053

SCALE AT A1:

ZONE SECTIONS

PROJECT NO:

1 : 100 001

DATE:

DRAWN:

CHECKED:

01.03.18 Author

Checker

DRAWING NO:

REVISION:

A300

4


ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS.CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.

0 10 20 30

Notes:

40 50 60 70 80 90 100 4 Final Package 12/05/18

3 Mid Sem Presentation 17/04/18

2 Preliminary Design 22/03/18

REV

1 Project Set Up

STATUS: DESCRIPTION

03/03/18

PRELIMINARY DATE

DYNAMIC ARCHITECTS

Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au CLIENT:

ARCHITECT:

DYNAMIC ARCHITECTS SITE:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION TITLE:

81/89 BOUVERIE ST, CARLTON VIC 3053 SCALE AT A1:

SECTION A PROJECT NO:

1 : 100 001

DATE:

A301

DRAWN:

CHECKED:

01.03.18 Author Checker

DRAWING NO: REVISION:

4

A

1 : 100

SECTION A

FT02 300mm HOLOCORE CONCRETE FLOOR TO SIT ON CONCRETE FOOTING.

WT04 300mm CONCRETE FLOOR AROUND THE BASEMENT BOUNDARY. REFER TO PLAN

LOBBY & CAFE ON GROUNDFLOOR. REFER TO PLAN

MEETING ROOM. REFER TO PLAN

LECTURE ROOM. REFER TO PLAN

CLASSROOM 02. REFER TO PLAN

FT02 150mm CONCRETE SLAB

CLASSROOM 04. REFER TO PLAN

CLASSROOM 06. REFER TO PLAN

LIFT 01 & LIFT 02. REFER TO PLAN

OFFICE ROOM. REFER TO PLAN

PHD RESEARCH ROOM. REFER TO PLAN

MAIN FEATURE STAIRS. REFER TO DETAILS

MALE, FEMALE, DISABLED TOILETS. REFER TO PLAN

STUDENT LOUNGE. REFER TO PLAN

STUDENT LOUNGE. REFER TO PLAN

FT03 GLASS FLOOR TO BE SUPPORTED BY STEEL BEAMS ATTACHED TO COLUMNS AND FLOOR SLAB

STEEL BEAM BETWEEN COLUMNS

ROOFTOP GARDEN. REFER TO PLAN

CW TO BE 1.5m TALL ON LEVEL 10

STEEL PEGOLAR WITH SHADE CLOTHS.

CW01

CW01

CW01

A600

2

CW01

CW01

CW01

CW01

CW01

CW01

CW01

CW09

6

5

4 WT07

3

2

1

4500

Level 1

9000

Level 2

13500

Level 3

18000

Level 4

22500

Level 5

-4000

BASEMENT

0

GROUND FLOOR

WT02

27000

Level 6

31500

Level 7

36000

Level 8

40500

Level 9

45000

Level 10

49500

ROOF

CONCRETE PILE

CONCRETE STRIP FOOTING

WORKSHOP BASEMENT

BASEMENT LOBBY

EXHIBITION ROOM

WT 02 BRICK VENEER

VERTICAL WIND TUNNEL

WORKSHOP 01

WIND TUNNEL MACHINE ZONE

WORKSHOP 02

TIMBER TRUSS FRAME

HANGING BOX

WORKSHOP 03

LIFT SERVICE

WT 03 BLOCK VENEER

WORKSHOP 04

WT 07 CURTAIN WALL

STEEL BEAM

WORKSHOP 05

STEEL BEAM RAFTERS CONNECTED TO CELLULAR STEEL BEAM

HVAC PLANTS ON ROOF

SKY LIGHT


ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS.CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.

0 10 20 30

Notes:

40 50 60 70 80 90 100 4 Final Package 12/05/18

3 Mid Sem Presentation 17/04/18

2 Preliminary Design 22/03/18

REV

1 Project Set Up

STATUS: DESCRIPTION

03/03/18

PRELIMINARY DATE

DYNAMIC ARCHITECTS

Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au CLIENT:

ARCHITECT:

DYNAMIC ARCHITECTS SITE:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION TITLE:

81/89 BOUVERIE ST, CARLTON VIC 3053 SCALE AT A1:

SECTION B PROJECT NO:

1 : 100 001

DATE:

A302

DRAWN:

CHECKED:

01.03.18 Author Checker

DRAWING NO: REVISION:

4

B

CW01

CW03

CW03

CW04

CW03

CW01

CW05

CW03

CW04

CW04

CW01

1 : 100

SECTION B

BASEMENT WORKSHOP. REFER TO PLAN

DT01 MAIN ENTRANCE

LOBBY & CAFE. REFER TO PLAN

ALL EXPOSED STEEL STRUCTURES TO BE FIREPROOFED WITH PAINTING

LECTURE ROOM FLOOR.

FEATURE STAIRS & WIRE BALUSTRADE. REFER TO DETAIL

STEEL I BEAM TO SUPPORT FT03 GLASS FLOOR. REFER TO DETAIL

400x400mm CONCRETE COLUMN

DT04 SINGLE DOOR ON CURTAIN WALL TO BE 2.5m TALL

WT01 MODULAR CURTAIN PANEL. REFER TO DETAIL

DT05 DOUBLE DOOR ON CURTAIN WALL TO BE 2.5m TALL

DT04 SINGLE DOOR ON CURTAIN WALL TO BE 2.5m TALL

WT08 200mm TIMBER CLADDED WALL

PHD RESERACH ROOM KITCHEN. REFER TO PLAN

WT03 230mm BLOCK VENEER WALL

DT01 TO BE 3m TALL

WT07 CURTAIN WALL BETWEEN WT03 VLOCK VENEER WALL

MAIN FEATURE STAIRS ON LVL8-10 TO BE REVERSED. REFER TO PLAN FOR DETAIL

DT01 AUTOMATIC SLIDING DOORS

SKY LIGHTS TO HAVE WINOW PANELS ON BOTH ENDS

WT07

A

B

WT07

A

WT07

A301

WT07

C

WT07

D

E

WT04

-4000

BASEMENT

0

GROUND FLOOR

4500

Level 1

9000

Level 2

13500

Level 3

18000

Level 4

22500

Level 5

27000

Level 6

31500

Level 7

36000

Level 8

40500

Level 9

45000

Level 10

49500

ROOF

CONCRETE PILE

CONCRETE STRIP FOOTING

DT03 TO BIKE ROOM

CEILING ZONE

WT08 200mm TIMBER CLADDED WALL FOR CAFE KITCHEN

TIMBER FEATURE CEILING. REFER TO RCP

WT07 CURTAIN WALL FOR MEETING ROOMS

DT01 TO BE 3m TALL

WT06 100mm TMBER STUD WALL

400x400mm CONCRETE COLUMN

STEEL BEAM BETWEEN COLUMNS ATTACHING STAIRS AS WELL

STEEL BEAM BETWEEN COLUMNS ATTACHING STAIRS AS WELL

DT03 DOUBLE DOOR

FIRE ESCALE 01. REFER TO PLAN

WT04 & WT05 CONCRETE WALL. REFER TO PLAN

STUDENT LOUNGE AREA. REFER TO PLAN

STEEL BEAM BETWEEN COLUMNS TO BE FIREPROOFED WITH PAINTING

LIFT 01 & 02. REFER TO PLAN

HVAC UNIT ON ROOF

ROOF PLANTS TO BE POSITIONED FOR ACCESSABILITY BETWEN UNITS


B

4

3

A302

2

1

LT03 CEILING ZONE

STEEL BEAM BETWEEN COLUMNS PENDANT LIGHT TO ATTACH TO FLOOR ABOVE

LT02

LT02 50mm TILE CEILING

SCONCE LAMP TO ATTACH TO COLUMN

WT04 300mm CONCRETE WALL

SEMINAR ROOMS

MAIN FEATURE STAIRS

08

CORRIDOR 02

CORRIDOR 03

05

06

FIRE ESCAPE STAIRS 02

PENDANT LIGHT TO ATTACH TO FLOOR ABOVE

WT07 LT03

LT03

VERTICAL STEEL WIRE TO BE ATTACHED TO FLOOR BELOW AND ABOVE SUPPORTING THE HANING BOX

LT03 WT07 CURTAIN WALL WITH 150x50mm ALUMINIUM MULLION

DIAGRONAL STEEL WIRE TO BE ATTACHED TO FLOOR BELOW AND ABOVE SUPPORTING THE HANING BOX

WT02 VOID

FURTNITURES TO FACE WORKSHOP

Level 4 FT03

FT06

18000

FT01

FT01 150mm HOLLOW CORE CONCRETE FLOOR

WT05 1 FEATURE TIMBER TRUSS CEILING

LT01

LT03 FT03 GLASS FLOOR. REFER TO DETAIL

LT03

LT01 PENDANT LIGHTS TO BE PLACED BETWEEN TIMBER TRUSS HANGING FROM FT01

LT04

07 LT03

FIRE ESCAPE STAIRS

400x400mm CONCRETE COLUMN FEATURE WALL LIGHT. REFER TO MANUFACTURE'S DETAIL

MAIN FEATURE STAIRS WITH WIRE BALUSTRADE. REFER TO DETAIL

MAIN FEATURE STAIRS

WT07

WT03

STEEL BEAM TO SUPPORT GLASS FLOOR TO BE ATTACHED TO COLUMN

CLASSROOM 01

A400

CORRIDOR 02

WT03 BLOCK VENEER WITH WT07 CURTAIN WALL IN BETWEEN. REFER TO DETAIL

05

CURTAIN WALL BETWEEN BRICK VENEER. REFER TO DETAIL

WORKSHOP 06

WT02 BRICK VENEER. REFER TO DETAIL

STEEL BEAMS SUPPORTING GLASS TO BE WELDED TOGETHER IN SHOP BEFORE INSTALLMENT. REFER TO DETAIL

WT07 LT03 STEEL BEAM WITHIN CEILING ZONE

FT02 300mm CONCRETE SLAB

WT03

Level 3 FT03

FT06

13500

FT01 FT02

C

Section 1 1 : 20

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS.CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.

0

10

20

30

Notes:

40

4

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV

STATUS:

50

60

70

80

90

100

DESCRIPTION

PRELIMINARY

DATE

DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

CLIENT:

SITE:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:

DYNAMIC ARCHITECTS

TITLE:

81/89 BOUVERIE ST, CARLTON VIC 3053

SCALE AT A1:

SECTION C

PROJECT NO:

1 : 20 001

DATE:

DRAWN:

CHECKED:

01.03.18 Author

Checker

DRAWING NO:

REVISION:

A304

4


6

5

4

6

2

7

A403

A402

A403

3

CW01 Level 5 FT06

FT03

22500

FT02 REFER TO DETAIL FOR GLASS FLOOR

LT03

LT02

LT02

STEEL BEAM BETWEEN COLUMNS TO BE EXPOSED AND FIRERATED WITH INTUMESCENT PAINT

LT02

LT02

STEEL BEAM BETWEEN COLUMNS TO BE EXPOSED AND FIRERATED WITH INTUMESCENT PAINT

PENDANT LIGHT TO ATTACH INTO FT02 ABOVE

LT03 SCONCE LIGHT TO ATTACH INTO WT08

MAIN FEATURE STAIR TO BE FOLDED STEEL ATTACHED TO FLOOR SLAB AND SUPPORTED WITH TENSION WIRE. REFER TO DETAIL

CW01 SEMINAR ROOMS LT03

08

LT03

WT07

CORRIDOR 02 05

LT03

WT07

CORRIDOR 03 06

WT07 LT03

LT03

LT03 TENSION WIRE TO ATTACH ONTO BEAM AND FLOOR SLAB ABOVE

Level 4 FT03

FT06

18000

FT01 T BEAM AND I BEAM TO BE WELDED TOGETHER PRIOR TO INSTALATION

TENSION WIRE TO DIVIDE BETWEEN LEVELS AND ATTACHED INTO I BEAM

LT03 LT06

LT01

LT06

LT01

LT01

I BEAM TO SUPPORT FT03 AND ATTACHED ONTO COLUMN. REFER TO DETAIL

LT01

LT01

LT06

LT01

LT01

WALL LAMP TO ATTACH ONTO WT03 REFER TO RCP

LT01

LT03

PENDANT LIGHT TO ATTACH INTO FT02 ABOVE

WT03

LT04 TIMBER TRUSS AS FEATURE CEILING.

WT08 400x400mm CONCRETE COLUMN

STEEL BEAM BETWEEN COLUMNS AND FIRERATED

RECESSED LIGHTS TO BE ATTACHED INTO CEILING ZONE

LT03 CW03

CW10

PENDANT LIGHT TO HANG FROM CEILING

50mm CEILING UNDER BEAM LEVEL

FT02 300mm HOLOCORE CONCRETE

SCONCE LIGHT TO ATTACH INTO WT08

CLASSROOM 01

CORRIDOR 02

07 PROPRIETRAY FURNITURES TO CLASSROOMS. REFER TO MANUFACTUER'S DETAIL

LT03

LT03

FT01 150mm HOLLOWCORE CONCRETE. REFER TO DETAIL

WORKSHOP D01

05

06 WORKSHOP TO BE EQUIPED WITH SPECIFIC MACHINERY. REFER TO FACULTY OFFICE

TENSION WIRE TO BE INSTALLED 120mm APART THAT SUPPORT STAIRS AND HAND RAILS. REFER TO DETAIL

D03

FT01 TO SAWTOOTH ATTACHING TO WT01. REFER TO DETAILS HANDRAILS TO COMPLY BCA AND AS1170.1

Level 3 FT06

FT03

13500

FT02

CW04

D

Section 2 1 : 20

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS.CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.

0

10

20

B A302

30

Notes:

40

4

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV

STATUS:

50

60

70

80

90

100

DESCRIPTION

PRELIMINARY

DATE

DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

CLIENT:

SITE:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:

DYNAMIC ARCHITECTS

TITLE:

81/89 BOUVERIE ST, CARLTON VIC 3053

SCALE AT A1:

SECTION D

PROJECT NO:

1 : 20 001

DATE:

DRAWN:

CHECKED:

01.03.18 Author

Checker

DRAWING NO:

REVISION:

A305

4


Notes: 1

A

B

R‐VALUE CALCULATION FOR WT02 BRICK VENEER EXTERIROR WALL

5010050

1

BRICK VENEER 10mm MOTAR GAP

BRICK VENEER: 40mm AIR GAP: KINGSPAN Kooltherm K18 Insulated Plasterboard:

0.50 0.3 2.0

TOTAL R‐VALUE:

2.8

BRACE FASTENING BRICKS ATTACHED TO STEEL BEAM

BRICK VENEER

FIREESCAPE STAIRS 02 REFER TO PLAN FOR DETAIL

100x100mm STEEL BEAM ATTACHING BRACE

STEEL BRACE WITH WEEPED SCREED

900

BRICK VENEER 40mm AIR GAP

50x50mm TIMBER SUB STRUCTURE TO ATTACH INSULATION AND PLYWOOD SUBSTRATE

CW01

1170

WATER PROOF MEMBRANE

SEALANT

WT02 40mm RIGID INSULATION 10mm PLYWOOD SUBSTRATE

BRICK VENEER

PLASTER BOARD

WATERPROOF MEMBRANE

50x50mm TIMBER BLOCK FIXING UNIT

40mm AIR GAP

WATERPROOF MEMBRANE BETWEEN MULLION AND STEEL BEAM

40mm RIGID INSULATION BRICK VENEER ZONE

10mm PLYWOOD SUBSTRATE PLASTERBOARD TO ATTACHED ONTO SUBSTRATE

WT07

150

150mm CONCRETE FLOOR REFER TO PLAN FOR DETAIL ANCHOR BOLTS WITH TIEBACKS ATTACHED TO FLOOR

6mm LOW E INSULATING TEMPERED GLASS

Level 4

BRICK VENEER ZONE

LOW E DOUBLE GLAZED CURTAIN WALL

Level 4

6900

150x80mm STEEL MULLION

18000

18000 150x50mm STEEL MULLION. REFER TO DETAIL

LOW E DOUBLE GLAZED CURTAIN WALL

100x100 STEEL BEAM ATTACHED TO FLOOR

12mm ARGON GAS 50

150x60mm STEEL MULLION TO BE SEALED FOR WATERPROOFING

100x100mm STEEL BEAM WELDED TOGETHER

6mm LOW E INSULATING TEMPERED GLASS

U-MAX THERMAL BREAK 150x60mm FRONT DOUBLED GLAZED WINDOW C A304

250

4350

CW01 MODULAR CURTAIN WALL REFER TO FACADE DETAIL

50x50mm TIMBER BLOCK TO SIT BETWEEN INSULATION AND PLYWOOD

WT02

950

WATER TO FALL THROUGH WEEPING HOLE

5010050

270

WT02

STEEL BRACE WITH WEEPED SCREED

BRICK VENEER ZONE

BRICK VENEER

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

DYNAMIC ARCHITECTS

Level 3

1700

BRICK VENEER

DATE

PRELIMINARY

STATUS:

BRICK VENEER ZONE

BRICK VENEER ZONE

40mm AIR GAP

WT04

4

REV DESCRIPTION

SEALANT

Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

13500

WATERPROOF MEMBRANE

40mm AIR GAP 40mm RIGID INSULATION CLIENT:

10mm PLYWOOD SUBSTRATE

PLASTERBOARD TO ATTACHED ONTO SUBSTRATE

WATERPROOF MEMBRANE

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION

5010050

ANCHOR BOLTS WITH TIEBACK ATTACHED TO WALL

300

ARCHITECT:

150

A

100x100 STEEL BEAM ATTACHED TO FLOOR

Level 3

ANCHOR BOLTS WITH TIEBACKS ATTACHED TO FLOOR

13500

DYNAMIC ARCHITECTS LOW E DOUBLE GLAZED CURTAIN WALL

BRICK VENEER ZONE

10050

760

5010050

BRICK VENEER ZONE

2950

TITLE:

TYPICAL FACADE 01

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

5010050

SCALE AT A1:

2

FACADE DETAIL PLAN 1 : 10

1

FACADE DETAIL SECTION 1 : 10

3

N/A

FACADE DEATIL ELEVATION

PROJECT NO:

DATE:

01.03.18 Author Checker DRAWING NO:

001

1 : 20 0

10

20

CHECKED:

DRAWN:

REVISION:

4

A400 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


BENT STEEL PLATE CAPPED AT FFL

SEALANT W BACKING ROD 10MM THICK STEEL PLATE SPACER BOLTED TO FLOOR PLATE

FIRESTOP WITH SMOKE SEAL

6MM LAMINATED IGU GLASS

CURTAIN WALL STACK JOINT SYSTEM ANCHORED TO CONCRETE SLAB

BENT STEEL PLATE CAPPED AT FFL FIRESTOP WITH SMOKE SEAL FLOOR FINISH - VINYL 40MM SUB-FLOOR INSULATION FFL

6MM LAMINATED IGU GLASS

6MM LAMINATED IGU GLASS

BENT STEEL PLATE CAPPED AT FFL

STEEL ANCHOR PLATE

IGU SPACER BAR WEATHER SEALANT CUSTOM MULLIPON CASING SET IN STRUCTURAL FACADE FRAMING

IGU SPACER BAR WEATHER SEALANT

FIRESTOP WITH SMOKE SEAL

FLOOR FINISH - VINYL

IGU SPACER BAR WEATHER SEALANT

FLOOR FINISH - VINYL 40MM SUBFLOOR INSULATION

SEALANT W BACKING ROD 40MM SUB-FLOOR INSULATION

FFL

CUSTOM MULLIPON CASING SET IN STRUCTURAL FACADE FRAMING

CUSTOM MULLIPON CASING SET IN STRUCTURAL FACADE FRAMING

FFL

STRUCTURAL SEALANT RFL

RFL

STRUCTURAL SEALANT

RFL

STRUCTURAL SEALANT

5MM THICK, 70MM DIAMETER STEEL DIAGONAL SUPPORT HORIZONTAL TUBE. SUNSHADE MESH PANEL INDERTED INTO TUBE SUNSHADE MESH PANEL INSERT

5MM THICK, 70MM DIAMETER STEEL HORIZONTAL TUBE. FACADE PANEL STRUCTURAL SUPPORT 5MM THICK, 70MM DIAMETER STEEL HORIZONTAL TUBE. FACADE PANEL STRUCTURAL SUPPORT

5MM THICK, 70MM DIAMETER STEEL DIAGONAL SUPPORT HORIZONTAL TUBE.

HOLLOW CORE COCRETE SLAB HOLLOW CORE COCRETE SLAB

CELLULAR BEAM LB460x30

LOWER STRUCTURAL STEEL FACADE FRAMING

300 MM HOLLOW CORE COCRETE SLABSAW TOOTH PLAN TO ACCOMODATE DIAGONAL FACADE PANEL

INSULATED ALUMIUM COMPOSITE PANEL REFER TO A600 FOR ASSEMBLY CELLULAR BEAM LB460X30

INSULATED ALUMINIUM COMPOSITE PANEL. REFER TO A600 FOR ASSEMBLY

SUSPENSION WIRE BOLETED TO FLOOR SLAB

SUSPENSION WIRE BOLETED TO FLOOR SLAB

CEILING EDGE CAP

CEILING EDGE CAP

CEILING EDGE CAP SUSPENDED CELING PANEL

SUSPENDED CEILING PANEL

SEALANT W BACKING ROD

SUSPENDED CEILING PANEL

BENT STEEL PLATE CAPPED AT FFL FIRESTOP WITH SMOKE SEAL

10MM THICK STEEL PLATE SPACER BOLTED TO FLOOR PLATE BENT STEEL PLATE CAPPED AT FFL 3

FIRESTOP WITH SMOKE SEAL

A401

FLOOR FINISH - VINYL 40MM SUB-FLOOR INSULATION FFL

6MM LAMINATED IGU GLASS

INSULATED ALUMIUM COMPOSITE PANEL REFER TO A600 FOR ASSEMBLY

BENT STEEL PLATE CAPPED AT FFL

IGU SPACER BAR WEATHER SEALANT

STEEL ANCHOR PLATE

IGU SPACER BAR WEATHER SEALANT

6MM LAMINATED IGU GLASS

INSULATED ALUMINIUM COMPOSITE PANEL. REFER TO A600 FOR ASSEMBLY

CURTAIN WALL STACK JOINT SYSTEM ANCHORED TO CONCRETE SLAB

FIRESTOP WITH SMOKE SEAL SEALANT W BACKING ROD

40MM SUBFLOOR INSULATION

CUSTOM MULLIPON CASING SET IN STRUCTURAL FACADE FRAMING

CUSTOM MULLIPON CASING SET IN STRUCTURAL FACADE FRAMING

FFL

STRUCTURAL SEALANT

STRUCTURAL SEALANT

RFL

RFL

IGU SPACER BAR WEATHER SEALANT

FLOOR FINISH - VINYL

FLOOR FINISH - VINYL

40MM SUB-FLOOR INSULATION

CUSTOM MULLIPON CASING SET IN STRUCTURAL FACADE FRAMING

FFL

RFL

STRUCTURAL SEALANT

5MM THICK, 70MM DIAMETER STEEL DIAGONAL SUPPORT HORIZONTAL TUBE. SUNSHADE MESH PANEL INDERTED INTO TUBE SUNSHADE MESH PANEL INSERT

D A304

LOWER STRUCTURAL FACADE FRAMING 5MM THICK, 70MM DIAMETER STEEL HORIZONTAL TUBE. FACADE PANEL STRUCTURAL SUPPORT

5MM THICK, 70MM DIAMETER STEEL HORIZONTAL TUBE. FACADE PANEL STRUCTURAL SUPPORT

5MM THICK, 70MM DIAMETER STEEL DIAGONAL SUPPORT HORIZONTAL TUBE.

5

HOLLOW CORE COCRETE SLAB

A401

6LAMINATED IGU GLASS

lEVEL 1 CONCRETE SLAB

CONCRETE BEAM LB460x30

2

FACADE PLAN DETAIL 1 : 10

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS.CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.

0

10

20

30

Notes:

40

Sample Notes

3

INSULATED ALUMIUM COMPOSITE PANEL REFER TO A600 FOR ASSEMBLY

FACADE SECTION DETAIL 1

4

1:5

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

70

80

90

100

DESCRIPTION

PRELIMINARY

5

1:5

Final Package

STATUS:

60

FACADE SECTION DETAIL 2

4

REV

50

300 MM HOLLOW CORE COCRETE SLABSAW TOOTH PLAN TO ACCOMODATE DIAGONAL FACADE PANEL

DATE

DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

CLIENT:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:

DYNAMIC ARCHITECTS

FACADE SECTION DEATIL 3 1:5

SCALE AT A1:

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053 TITLE:

DETAILS 03 GLASS FACADE

DATE:

DRAWN:

As 01.03.18 Author indicated

PROJECT NO:

001

DRAWING NO:

A401

CHECKED:

Checker REVISION:

4


A

B

C

WELDED STEEL BRACKET TO BE INSERTED INTO CONCRETE SLAB

400x470mm CONCRETE COLUMN

3

WELDED STEEL BRACKET TO BE INSERTED INTO COLUMN

10800

A402

400x400mm CONCRETE COLUMN

SILICON SEALENT LAMI COMPATIBLE

WT02 BRICK VENEER WALL

3

WELDED STEEL BRACKET TO ATTACH INTO COLUMN

3000

3000 2000

PANAL A

PANAL B

PANAL B

30mm COVER PANEL MADE OF SGS GLASS

T BRACKET DIVIDING GLASS PANELS

WT01 MODULAR GLASS WALL

• •

STEEL I BEAM TO CONNECT TO CONCRETE COLUMN VIA CAST IN CONCRETE BRACKET

AIR GAP

FT03 FRAMES TO BE CONSTRUCTED AT SHOP THEN DELIVERED TO SITE FOR FITTING ALL WELDED FRAMES TO BE GRIDED IN SHOP ALL EXPOSED METAL TO BE FIRERATED BY USING INTUMESCENT PAINT STEEL BRACKET TO CAST INTO CONCRETE COLUMN FT03 GLASS FLOOR PANELS TO CUT AND FIT TO LAY WITHIN THE STEEL FRAMES. REFER TO MANUFACTURE'S DETAIL STEEL BRACKETS ON CONCRETE COLUMNS TO BE INSTALLED DURING COLUMN CONSTRUCTION

• •

WELDED STEEL BRACKET TO ATTACH INTO COLUMN

SILICON PROFILE 60-70 SHORE

TRIPLE LAYERED TEMPERED GLASS FLOOR

WORKSHOP ENTRANCE 3000

Notes:

4

2

FT 01 150mm CONCRETE FLOOR

50mm SGS GLASS 50mm SGS GLASS

PANAL B

Level 5 2

A402

22500

VOID 1850

PANAL C

TRIPLE LAYERED GLASS FLOOR STEEL I BEAM SUPPORTING GLASS FLOOR TO CONNECT VIA CAST IN CONCRETE

WELDED STEEL BRACKET ATTACHED TO CONCRETE SLAB

4

T BRACKET TO BE WELDED TOGETHER IN SHOP BEFORE INSTALLATION

4 A402

FT02 300mm CONCRETE FLOOR

D

A305

1

I BEAM UNDER TO SUPPORT WELDED STEEL BRACKET

A402

3

A402

WELDED STEEL BRACKET ATTACHED TO CONCRETE SLAB

1

SECTION 01 MAIN STAIRS. REFER TO STAIRS DETAIL

1 : 20 2 A402

TESNTION WIRE TO BE ATTACHED TO I BEAM

4 SILICON SEALENT LAMI COMPATIBLE

30mm COVER PANEL MADE OF SGS GLASS

SILICON PROFILE 60-70 SHORE

50mm SGS GLASS

3

BALUSTRADE TO BE ATTACHED TO TENSION WIRE HAND RAIL TO BE ATTACHED TO TENSIONWIRE WITH CLAMP

50mm SGS GLASS

WT03 BLOCK VENEER WALL AND WT07 CURTAIN WALL. REFER TO WALL DETAIL 30mm COVER PANEL MADE OF SGS GLASS

50mm SGS GLASS 50mm SGS GLASS STEEL BRACKET TO ATTACH INTO FLOOR SLAB AND COLUMN

TENSION WIRE

Level 5 T BRACKET AND I BEAM TO BE WELDED TOGETHER IN SHOP BOFORE INSTALLATION

BRACKETS WELDED TOGETHER IN SHOP BEFORE INSTALLATION

22500

I BEAM TO CONNECT INTO COLUMN TO ENFORCE STRENGTH

TENSION WIRE TO CONNECT INTO I BEAM

I BEAM TO BE INSERTED INTO COLUMN AND FLOOR TO BE INSATLLED FIRST

I BEAM SUPPORTING BRACKET TO BE WELDED BEOFRE INSTALLATION

VOID

CAST IN CONCRET BRACKET TO CONNECT I BEAM I BEAM AND BRACKET TO BE WELDED IN SHOP

4

GLASS DETAIL

3

1:5

STAINLESS STEEL BRACKET TO HOLD GLASS FLOOR

3

C

A402

Section 02 1 : 20

STAINLESS STEEL BRACKET TO HOLD GLASS FLOOR

I BEAM TO SUPPORT BRACKET TO BE WELDED IN SHOP BEOFRE INSTALLATION

B

1

A

A402

I BEAM TO BE ATTACHED WITH CONCRETE SLAB

4

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV DESCRIPTION

PANEL A

PANEL B

PANEL B

PANEL B

PRELIMINARY

STATUS:

WT 01 MODULAR GLASS PANEL

DATE

DYNAMIC ARCHITECTS

Level 5

Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

22500

CLIENT:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:

DYNAMIC ARCHITECTS

2

LONG SECTION

TITLE:

DETAIL 01 GLASS FLOOR

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

SCALE AT A1:

N/A

1 : 20

PROJECT NO:

DATE:

01.03.18 Author Checker DRAWING NO:

001 0

10

20

CHECKED:

DRAWN:

REVISION:

4

A402 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


D

7807

A

B

A305

8

1

A403

A300

2750

3000

2307

2750

WT08

WT08

WT08

7807

WT08

3000

CW03

Notes:

C

2750

2308

2750

INTERIOR

4

EXTERIOR

3310

Level 6

24 23

27000

22

WT07

2250

6

A403

D05

19 18

STEEL STAIR CASE ATTACHED TO STEEL PLATE ON SLAB. CONNECTION POINTS WELDED AT STRINGER EDGE

17

24 EQ RISERS 250MM GOINGS

INTERIOR

16 15 14 13

A403

7

1

11

A403

10 9 8

2250

7

WT03

WT07

24 RISERS AT 250MM

12

WT03

EXTERIOR

CW01

4600

1500

1958

21 20

6 5 4 3 2 1

3

Level 5

5

C

1

A300

A403

8

B

A305

D

A

DT01

22500

STAIRS PLAN LAYOUT

6

STAIRS SECTION 01 1 : 50

1 : 50

4

D

A

30MM ANODIZED ALUMINIUM HANDRAIL

6

B

A305

8

1

A403

A300

C

A403

1585

83 52

24

52

Level 6

23

27000

27000 5MM STEEL CABLE BALUSTRADE 84

Level 6

0

24

CUSTOM STEEL CABLE CLAMP

EXTERIOR

INTERIOR

750

22 21 20

TENSION CABLE BALLUSTRADE ATTACHED TO I BEAM SPACED 120MM TO ADJACENT

19 12MM ROUND STEEL HANDRAIL SUPPORT CONNECTED TO STEEL CLAMPS

18

125

17 1500

16 CUSTOM STEEL CABLE CLAMP 15 14

MAIN FEATURE STAIRS WITH WIRE BALUSTRADE. REFER TO DETAIL

Level 5 22500

13 4500

CUSTOM STEEL WIRE CLAMP BOLTED TO SHS SUB-LANDING

2

BALLUSTRADE HANDRAIL DETAIL

7

1:2

STAIRS ELEVATION 1 : 50

80

110

4

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV DESCRIPTION

PRELIMINARY

STATUS:

35

DATE

VINYL TREAD COVERING FLUSH AGAINST RISE

CENTRAL BALLUSTRADE HANDRAIL

DYNAMIC ARCHITECTS

35

2250

NICKEL NON-SLIP INSERT

Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

10MM FOLDED STEEL TREAD 188

BENT STEEL SUPPORT WELD ON STRINGER

2 A403

STEEL BEAMS SUPPORTING GLASS REFER A304 FOR DETAILING

24

Level 5

23

22500

7.82°

50

GOING PROFILE BENT TO BACK OF RISER

CLIENT:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION

332

ARCHITECT:

DYNAMIC ARCHITECTS

22 21

RISER PROFILE

20 19

55

LANDING ON 150X80X9.0 SHS BEAM

PRIMARY STEEL STRINGER 50MM

TITLE:

DETAILS 02 STAIRS

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

18 17

SCALE AT A1:

N/A PROJECT NO:

8

STAIRS SECTION 02 1 : 20

1

STAIRS SECTION 01 - DETAIL 1:5

DATE:

01.03.18 Author Checker DRAWING NO:

001 0

10

20

CHECKED:

DRAWN:

REVISION:

4

A403 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


Notes:

3 3 WT02 BRICK VENEER. BRICK TO WRAP AROUND THE CORNER AND ATTACH WT01 TUBE FRAME

400x400mm CONCRETE COLUMN

2000

WT07 CURTAIN WALL TO FIT BETWEEN WT03 BLCOK VENEER WALL

A

WORKSHOP TO BE EQUIPED WITH SPECIFIC MACHINERY. REFER TO FACULTY OFFICE

ROD BRACES TO SUPPORT HANGING BOX BY ATTACHING TO BEAM AND FLOOR SLAB ABOVE

WT07

SCONCE LAMP TO BE ATTACHED TO CONCRETE COLUMN

2051

SUB‐MEZZANINE ‐ PRATT FLAT TRUSS SYSTEM. MEASUREMENTS AND ATTACHMENTS AS PER DRAWING SPECIFICATIONS

3033

ROD BRACES TO CONNECT SUB‐FLOOR TRUSS TO ABOVE I BEAMS AND CELLULAR BEAMS. ROD TENSION AS PER NCC REQUIREMENTS AND MANUFACTURERS' SPECIFICATIONS

FT03

MULLION TO ATTACH INTO GYPSUM PLASTER BLOCK VENEER

D A305

RIGID INSULATION GYPSUM PLASTER

WT03

SCONCE LAMP TO BE ATTACHED TO CONCRETE COLUMN

WT07 FT02 150mm HOLLOWCORE CONCRETE SLAB AIR GAP/TIMBER STACK

Level 5 22500

FT03

B

FT02 C

EXPOSED STEEL BEAM TO BE FIRERATED WITH INTUMESCENT PAINT

HANGING BOX MULLION TO ATTACH ONTO WALL ABOVE

PENDANT LIGHT TO ATTACH INTO FLOOR SLAB ABOVE

ROD BRACES TO ATTACH INTO BEAM ABOVE

212

A304

400

LT02

2000

C

470

FT03 STEEL FRAME TO ATTACH INTO FLOOR SLAB AND COLUMN

3310

ROD BRACES WIRE TO BE INSTALLED BEHIND 150x50mm STEEL MULLION

12/05/18

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV DESCRIPTION

DATE

PRELIMINARY

STATUS:

DIAGRONAL TENSION WIRE TO ATTACH INTO FLOOR SLAB

Level 4

DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

18000

FT01 51

FT03

Final Package

3

2000

FT01 150mm CONCRETE HOLOCORE

4

CLIENT:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION

600

WT04

DYNAMIC ARCHITECTS

LT01

SUB FLOOR TIMBER TRUSS EXPOSED AS FEATURE CEILING. TIMBER FIRE RATING AS PER NCC REQUIREMENTS

1509

1625

WT03

LT01

ARCHITECT:

D

PENDANT LIGHTING TO ATTACH INTO FLOOR SLAB ABOVE

TITLE:

DETAILS 03 HANGING BOX

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

230

SCALE AT A1:

LT04

1233

N/A

1541

PROJECT NO:

1

DETAIL 01 SECTION 1 : 10

2

DETAIL 01 PLAN 1 : 20

DATE:

01.03.18 Author Checker DRAWING NO:

001

2803 0

10

20

CHECKED:

DRAWN:

REVISION:

4

A404 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.


D

E

D

E

RECESSED CEILING WITH LIGHTING

DT02 900mm DOOR. REFER TO PLAN

TIMBER PANEL CEILING IN LOBBY SPACE. REFER TO RCP PLAN

WT08 TIMBER STUD WALL

TA05 LT01

COAT HOOK TO BE INTALLED ONTO EVERY DOOR. FOLLOW AS1428.1-2009 16.5

1

A510

3

1

A510

FT01

LT05

4

4 3

DISABLED TOILET LAYOUT TO COMPLY AUSTRALIAN STANDARDS. AS1428.1-2009 15.2.8; FIG 52

LT05

D02

D02

FT04 WT06

2

2

TA02

3168

MI03 LT01

TB01 TA01 TB06

LT05

TA03

TA04

JA04

JA02

D02

D02

D02

D02

LT01

CLEANING ROOM TO BE EQUIPED WITH ADEQUATE FACILITIES

LT05

DISABLED TOILET LAYOUT TO COMPLY AUSTRALIAN STANDARDS. AS1428.1-2009 15.2.8; FIG 52

5

5 LT01

JA03

JA01

1534

D07

MI02

TA03

MI02

D07

970mm TIMBER STUD WALL

TA02

150mm PLUMING SYSTEM WITHIN THE STUD WALL

LT01

LT01

FT04

LT01

LT01

MI01

TA04

D07

MI01

HAND TOWL AND DISPENSER TO MANUFACTURE'S DETAIL

D07

TA01

D07

FT04

2240

TA01

LT01

D07

LT01

TB01

LT01

900

FLUSHING CONTROL MOUNTED ON STUD WALL

TA04 3

TA03

TA04

TA04

TA04

WT08

TA04

1

1

TA04

WT06

TA01

4

D07

2

TA04 TA01

A511

1000

TB01

4

2

900

TOILET BOWL TO BE COMPLIED TO AUSTRALIAN STANDARDS. FOLLOW AS 1428.1-2009

A511

TA02

3

30mm LAMINATED TOILET PARTITION WALL

1000

TA03

TOILET CLEANING EQUIPMENT TO BE INSTALLED INTO ALL CUBICLE

TA02

TA02

TB02

D07

D07

TB01

D07

150mm PLUMBING CAVITY WITH THE TIMBER STUD WALL

LT01

900

TB01

1534

TA03

1604

8

5

TB02

A510

TA03

LT01

TA02

6

8

5

TA03

A510

6

DULE TOILET PAPER DISPENSER TO BE INSTALLED TO ALL CUBICLE. FOLLOW AS 1428.1-2009 15.2.6

7

7

1020

TA02 D07

LT01

6

6

CUBICLE WALL TO BE 600mm WIDTH MIN.

LT01

D07

TB01

D07

TB01

LT01

D07

300mm CONCRETE FACADE

FT04 60x60mm OZ TILE

WT01 MODULAR GLASS PANEL TO BE OPAQUE. REFER TO ELEVATION

1

0

10

20

30

TOILET UNIT TB01: CAROMA LIANO EASY HEIGHT INVISI II No.766500W TB02: CAROMA INTEGRA URINAL No.6651022W

60

70

80

90

100

TOILET AMENITY TA01: CAROMA MOON 500 WALL BASIN 1TH WHITE No.EU550715W TA02: HONANA BC‐621 CREATIVE TOILET BRUSH No.1226292 TA03: CAROMA VIRTU CIRCIT DOUBLE TOILET PAPER No.0961C TA04: DYSON AIRBLADE DB FT05 300678‐01 TA05: KOALA KARE STAINLESS BABY CHANGE TABLE HORIZONTAL KB110‐SSRE TA06: 90 LH+450 STRAIGHT GRAB RAIL SET RBA4090‐345

RECESSED CEILING WITH LIGHTING FINISHNG AT FACADE

MALE URINALS INSTALLED TO COMPLY AS1428.1-2009. REFER TO MANUFACUTER'S DETAIL

2

1 : 20

MIRROR MI01: ASI INTER‐LOCK FRAMED MIRROR 10‐0600‐V3036 MI02: ASI INTER‐LOCK FRAMED MIRROR 10‐0600‐V3636 MI03: ASI INTER‐LOCK FRAMED MIRROR 10‐0600‐V1839

50

WT08 90mm TIMBER STUD WALL

RECESSED CEILING WITH LIGHTING FINISHNG AT FACADE

TYPICAL AMENITIES PLAN

Notes:

40

WASH BASIN TO COMPLY AS1428.1-2009 15.3

4

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV

STATUS:

DESCRIPTION

PRELIMINARY

DATE

TYPICAL AMENITIES RCP 1 : 20

DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

CLIENT:

SITE:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:

DYNAMIC ARCHITECTS

TITLE:

81/89 BOUVERIE ST, CARLTON VIC 3053

SCALE AT A1:

TYPICAL AMENITIES PLAN

PROJECT NO:

1 : 20 001

DATE:

DRAWN:

CHECKED:

01.03.18 Author

Checker

DRAWING NO:

REVISION:

A500

NO RT H

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS.CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.

HAND TOWL AND DISPENSER TO REFER MANUFACTURE'S DETAIL

4


CEILING CAVITY TO FIT VENTS

E

2100

2768

1524

50

828

587

180

2745

180 183

TB06

180

533

1219

80

MIRROR AND HAND WASH POSITION TO COMPLY AS.1428.12009

FEATURE WALL AND COVER FOR PLUMBING CAVITY

TB06

948

MI01 D07

MI02

587

466

TA01

1200

180

DISABLED TOILET BOWL TO COMPLY AS1428.1-2009 15.2.8

TA02

TA03

TB01

80mm ALUMINIUM PILASTERS SHOES

TA02

TA01

534

805

TB01

150mm PLUMBING SYSTEM WITHIN THE STUD WALL CAVITY 610

FT01

1200

356

534

TA04

90

8270

TA03

534

TA04

TA01

356

479

TA01

600

D07

TB02 HANDWASH BASIN TO COMPLY WITH AS1428.1-2009

50

DULE TOILET PAPER DISPENSER 2335

MI03

1161

890

600

2700

MI03

1200

FIBER GLASS REINFORCED PLASTIC WALL. REFER TO MANUFACTURE' S DETAIL

HANDRAILS TO COMPLY AS1428.1-2009

1041

400

505

80mm ALUMINIUM HEAD RAIL

MIRRORS TO COMPLY AS1428.1-2009

DISABLED TOILET TO BE EQUIPED WITH HANDRAILS COMPLYING AS1428.1-2009

2340

2050

FIBER GLASS REINFORCED PLASTIC WALL. REFER TO MANUFACTURE'S DETAIL

624

1460

RECESSED CEILING

1900

200

200

FIBER GLASS REINFORCED PLASTIC WALL. REFER TO MANUFACTURE'S DETAIL

D02

3600

200

800

200

5

Level 3

80

850

RECESSED CEILING WITH LIGHT FITTING 200

50mm PLASTERBOAR D CEILING

6

150

150

150

LIGHTING FIXTURE TO REFER MANUFACTURE'S DETAIL

D

13500

DISABLED E

5

1 : 20

6

1 : 20

D

1500

2100

200

200 200

200 180

300

6

RECESSED CEILING

200 200

1 : 20

5

150

150

E

MALE N

933

150

2

1 : 20

MALE E

2768

1087

1594

200

50

990

3600

50mm PLASTERBOARD CEILING

550

1

DISABLED N

534

80

40mm RIGID INSULATION 80mm ALUMINIUM HEADRAIL

10mm GYPSUM BOARD 150mm CONCRETE WALL

TIMBER FEATURE CLADDING WALL

235 61 235 61 235 61 235 100 1500

765

287

1200

TA04

TA04

TB02

TA04

356

80mm ALUMINIUM PILASTERS SHOES

534

TB01

TA04

TB02

610

HAND TOWL AND BIN UNIT

PLUMBING CAVITY

351

51

1015

TB02 TA01

435

624

TIMBER FEATURE CLADDING WALL

478

610

PLUMBING CAVITY CAP

TA03

DISABLED TOILET BOWL TO COMPLY AS1428.1-2009

805

TA05

533

TB06

438

TB01

305

TIMBER CLADDING WALL

1200

1200

477

TA02

TA03

326

MALE URINAL TO REFER MANUFACTURE R'S DETAIL

D02

PLUMBING CAVITY CAP

FLUSHING PIPING TO BE INSTALLED WIHTIN PLUMBING CAVITY SPACE

395

110 175

D02

TB06

FIBER GLASS REINFORCED PLASTIC WALL. REFER TO MANUFACTURE'S DETAIL

TOILET BOWL TO COMPLY AS1428.1-2009

HANDRAILS TO COMPLY AS1428.1-2009

TIMBER STUD WALL WITH FEATURE TIMBER COMPOSITE CLADDING

100

1500

30mm PARTITION WALL

FIBER GLASS REINFORCED PLASTIC WALL. REFER TO MANUFACTURE'S DETAIL

TA05

2240

2350

2350

100mm TIMBER STUD WALL

TIMBER STUD WALL TO BLOCK VIEW

Level 3 13500

3

DISABLED S

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS.CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.

0

10

4

1 : 20

20

30

TOILET UNIT TB01: CAROMA LIANO EASY HEIGHT INVISI II No.766500W TB02: CAROMA INTEGRA URINAL No.6651022W

Notes:

40

MIRROR MI01: ASI INTER‐LOCK FRAMED MIRROR 10‐0600‐V3036 MI02: ASI INTER‐LOCK FRAMED MIRROR 10‐0600‐V3636 MI03: ASI INTER‐LOCK FRAMED MIRROR 10‐0600‐V1839

50

60

70

80

90

100

DISABLED W

7

1 : 20

TOILET AMENITY TA01: CAROMA MOON 500 WALL BASIN 1TH WHITE No.EU550715W TA02: HONANA BC‐621 CREATIVE TOILET BRUSH No.1226292 TA03: CAROMA VIRTU CIRCIT DOUBLE TOILET PAPER No.0961C TA04: DYSON AIRBLADE DB FT05 300678‐01 TA05: KOALA KARE STAINLESS BABY CHANGE TABLE HORIZONTAL KB110‐SSRE TA06: 90 LH+450 STRAIGHT GRAB RAIL SET RBA4090‐345

MALE S

4

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV

STATUS:

DESCRIPTION

PRELIMINARY

DATE

8

1 : 20

DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

MALE W

CLIENT:

1 : 20

SITE:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:

DYNAMIC ARCHITECTS

TITLE:

81/89 BOUVERIE ST, CARLTON VIC 3053

SCALE AT A1:

TYPICAL AMENITIES ELEVATIONS 01

PROJECT NO:

1 : 20 001

DATE:

DRAWN:

CHECKED:

01.03.18 Author

Checker

DRAWING NO:

REVISION:

A510

4


E

6

STEEL BEAM BETWEEN COLUMNS

5

50 100

RECESSED CEILING LIGHT SOURCE WITHIN CEILING CAVITY 1634

2100

200

200

550

200

4777

50mm PLASTERBOARD CEILING

80mm ALUMINIUM HEADRAIL

80

80

80

50

600

30 270 30

600

30 270 30

505

505

1080 600

30 270 30

600

30

30mm PARTITION WALL 1634

297 30

1450

FIBER GLASS REINFORCED PLASTIC WALL. REFER TO MANUFACTURE'S DETAIL

HAND WASH AND MIRROR POSITION TO COMPLY AS1428.1-2009

MI01

120

JANATORIAL EQUPMENTS

D07

D07

2335

JA04

2300

800

180

D07

JA02

D07 JA03

765

237

HAND TOWL AND BIN UNIT

TA01

587

TA04

TB01

435

643

TA04

80

80mm ALUMINIUM PILASTERS SHOES

Level 3

80

TA04

763

TA04

13500

1

FEMALE E

2

1 : 20

FEMALE N 1 : 20

5

E

FEMALE TOILET INTORIOR

6

3734 1010

80

50

50mm PLASTERBOARD CEILING

80

1440

200

LIGHT SOURCE WITHIN CEILING CAVITY

80mm ALUMINIUM HEADRAIL 1750

900

505

550

200

150

150

RECESSED CEILING

30

120 30

600

30

356

300

580

140100100

915

30

30mm PARTITION WALL 519

90

600

50

1200

300

587

D02

690

800

180

MI02 HAND WASH AND MIRROR POSITION TO COMPLY AS1428.1-2009

D07

D07

915

TA03

TB01

TB01

471

TA04 356

TOILET BOWL AND PAPER DISPENSER TO COMPLY AS1428.1-2009

TA03

Level 3

80

80

TA01

534

534

HAND TOWL AND BIN UNIT

TB01

435

TA01

TA01

TA03

1000

1200

1800

D07

MI01 2300

2840

FIBER GLASS REINFORCED PLASTIC WALL. REFER TO MANUFACTURE'S DETAIL

13500

3

FEMALE S

0

10

20

4

1 : 20

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS.CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.

30

TOILET UNIT TB01: CAROMA LIANO EASY HEIGHT INVISI II No.766500W TB02: CAROMA INTEGRA URINAL No.6651022W

Notes:

40

MIRROR MI01: ASI INTER‐LOCK FRAMED MIRROR 10‐0600‐V3036 MI02: ASI INTER‐LOCK FRAMED MIRROR 10‐0600‐V3636 MI03: ASI INTER‐LOCK FRAMED MIRROR 10‐0600‐V1839

50

60

70

FEMALE W

80

90

100

TOILET AMENITY TA01: CAROMA MOON 500 WALL BASIN 1TH WHITE No.EU550715W TA02: HONANA BC‐621 CREATIVE TOILET BRUSH No.1226292 TA03: CAROMA VIRTU CIRCIT DOUBLE TOILET PAPER No.0961C TA04: DYSON AIRBLADE DB FT05 300678‐01 TA05: KOALA KARE STAINLESS BABY CHANGE TABLE HORIZONTAL KB110‐SSRE TA06: 90 LH+450 STRAIGHT GRAB RAIL SET RBA4090‐345

6

1 : 20

4

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV

STATUS:

DESCRIPTION

PRELIMINARY

DATE

DYNAMIC ARCHITECTS Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

AMENITIES AXONOMETRIC NTS

CLIENT:

SITE:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:

DYNAMIC ARCHITECTS

TITLE:

81/89 BOUVERIE ST, CARLTON VIC 3053

SCALE AT A1:

TYPICAL AMENITIES ELEVATION 02

PROJECT NO:

1 : 20 001

DATE:

DRAWN:

CHECKED:

01.03.18 Author

Checker

DRAWING NO:

REVISION:

A511

4


A

Notes: Sample Notes

B

INTERCHANGEABLE PANELS IN MULLIONS REPLACE GLAZING. 11 VARIATIONS FITTED WITHIN STEEL FRAME. REFER TO DRAWING A200 FOR PLACEMENT OF PANELS REFER TO SCHEDULE MATRIX (BELOW) FOR INSERT PANEL TYPES

ASSEMBLAGE OF PANELS INTO TYPICAL MODULE FRAME.

C

ALL GLAZED, ALUMINIUM ON FRONT SURFACE TO MAINTAIN DIMENSIONS. PANELS FIT INTO INBUILD MULLIONS AND HOUSINGS IN FRAMES

MODULAR CURTAIN WALL AND INDIVIDUAL MODULES ACT AS STRUCTURAL TRUSS SYSTEM THAT INCORPORATES ANGLED GLAZING AND SUNSHADES ON WESTERN AND NORTHERN BORDERS. MODULES BECOME CONTINUOUS CURTAIN WALL AND VERTICLE SPACE FRAME REFER TO DRAWING A401 FOR CONNECTIONS TO ADJACENT MODULES AND FLOOR PLATES

D

TYPE

PANEL A

PANEL B

PANEL C

PANEL D

CW01 MESH INSERT SUNSHADE PANEL

IGU DOUBLE GLAZE PANEL

IGU DOUBLE GLAZE PANEL

INSULATED ALUMIUM COMPOSITE PANEL (FUCSHIA)

1

CW02 MESH INSERT SUNSHADE PANEL

BLUE TINTED IGUE DOUBLE GLAZE PANEL

INSULATED ALUMIUM COMPOSITE PANEL (PEACH)

MESH INSERT SUNSHADE PANEL

BLUE TINTED IGUE DOUBLE GLAZE PANEL

IGU DOUBLE GLAZE PANEL

MESH INSERT SUNSHADE PANEL

ROSE TINTED IGUE DOUBLE GLAZE PANEL

MESH INSERT SUNSHADE PANEL

ROSE TINTED IGUE DOUBLE GLAZE PANEL

FACADE AXO

INSULATED ALUMIUM COMPOSITE PANEL (PEACH)

CW03

CW04

IGU DOUBLE GLAZE PANEL

INSULATED ALUMIUM COMPOSITE PANEL (ORANGE)

INSULATED ALUMIUM COMPOSITE PANEL (PEACH)

CW05

CW06 MESH INSERT SUNSHADE PANEL

INSULATED ALUMIUM COMPOSITE PANEL (FUCSHIA)

BLUE TINTED IGUE DOUBLE GLAZE PANEL

IGU DOUBLE GLAZE PANEL

INSULATED ALUMIUM COMPOSITE PANEL (FUCSHIA)

INSULATED ALUMIUM COMPOSITE PANEL (PEACH)

4

Final Package

12/05/18

3

Mid Sem Presentation

17/04/18

2

Preliminary Design

22/03/18

1

Project Set Up

03/03/18

REV DESCRIPTION

DATE

PRELIMINARY

STATUS:

CW07 MESH INSERT SUNSHADE PANEL

ROSE TINTED IGUE DOUBLE GLAZE PANEL

INSULATED ALUMIUM COMPOSITE PANEL (RED)

DYNAMIC ARCHITECTS INSULATED ALUMIUM COMPOSITE PANEL (PEACH)

Building 100 Victoria St, Carlton VIC 3000 +61 03 9999 8888 +61 03 9999 8887 dynamicarchitects@gmail.com www.dynamicarchitects.com.au

CW08 MESH INSERT SUNSHADE PANEL

INSULATED ALUMIUM COMPOSITE PANEL (ORANGE)

ROSE TINTED IGUE DOUBLE GLAZE PANEL

INSULATED ALUMIUM COMPOSITE PANEL (ORANGE)

CLIENT:

RMIT SCHOOL OF AEROSPACE ENGINEERING AND AVIATION ARCHITECT:

CW09 MESH INSERT SUNSHADE PANEL

INSULATED ALUMIUM COMPOSITE PANEL (ORANGE)

INSULATED ALUMIUM COMPOSITE PANEL (RED)

CW10 MESH INSERT SUNSHADE PANEL

INSULATED ALUMIUM COMPOSITE PANEL (PEACH)

BLUE TINTED IGUE DOUBLE GLAZE PANEL

DYNAMIC ARCHITECTS

INSULATED ALUMIUM COMPOSITE PANEL (FUCSHIA)

INSULATED ALUMIUM COMPOSITE PANEL (RED)

TITLE:

GLASS FACADE ASSEMBLY

SITE:

81/89 BOUVERIE ST, CARLTON VIC 3053

SCALE AT A1:

DATE:

CHECKED:

DRAWN:

1 : 150 01.03.18 Author Checker PROJECT NO:

CW11 MESH INSERT SUNSHADE PANEL

IGU DOUBLE GLAZE PANEL

INSULATED ALUMIUM COMPOSITE PANEL (PEACH)

INSULATED ALUMIUM COMPOSITE PANEL (ORANGE)

DRAWING NO:

001

2

FACADE AXO - ASSEMBLY

0

10

20

REVISION:

4

A600 30

40

50

60

70

80

90

100

ALL DIMENSIONS ARE IN MILLIMETERS.DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR ABOVE. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS OR ORDERING MATERIALS.