Osram Catalog 2

Page 1

Technical data Product reference

Lamp current A

Lamp wattage W

Compensation capacitor at 50 Hz μF

Circuit Luminous diaflux lm gram no. 21)

Luminous efficacy lm/W

Color rendering Ra

Color temperature K

Burning position 22)

6600 6600 7700 7700 12000 12000

85 85 77 77 80 80

70 80 70 80 70 80

3000 4200 3000 4200 3000 4200

universal universal universal universal universal universal

6200 6200 7300 7300 11400 11400 17000 31000 25000

79 79 73 73 76 76 71 74 71

70 80 70 85 70 86 90 90 90

3000 4200 3000 4200 3000 4200 5200 5000 5200

universal universal universal universal universal universal universal universal universal

POWERSTAR® HQI®-E/P, clear, for open and enclosed fixtures HQI-E/P 70/WDL clear HQI-E/P 70/NDL clear HQI-E/P 100/WDL clear HQI-E/P 100/NDL clear HQI-E/P 150/WDL clear HQI-E/P 150/NDL clear

0.9 0.9 1.2 1.2 1.8 1.8

78 78 100 100 150 150

12 4) 12 4) 12 4) 12 4) 20 4) 20 4)

2/7 2/7 2/7 2/7 2/7 2/7

POWERSTAR® HQI®-E/P, coated, for open and enclosed fixtures HQI-E/P 70/WDL coated HQI-E/P 70/NDL coated HQI-E/P 100/WDL coated HQI-E/P 100/NDL coated HQI-E/P 150/WDL coated HQI-E/P 150/NDL coated HQI-E/P 250/D coated 2) HQI-E/P 400/D coated 2) HQI-E/P 400/D coated 10)

0.9 0.9 1.2 1.2 1.8 1.8 3.0 3.9 3.5

78 78 100 100 150 150 250 420 380

12 4) 12 4) 12 4) 12 4) 20 4) 20 4) 32 4) 45 4) 35 4)

2/7 2/7 2/7 2/7 2/7 2/7 2 2 2

POWERSTAR® HQI®-E, clear and coated, for enclosed fixtures HQI-E 400/N CLEAR 2) HQI-E 400/N CLEAR 10) HQI-E 250/D PRO 2) HQI-E 400/D PRO 2) HQI-E 400/D 10) HQI-E 400/N 2) HQI-E 400/N 10) HQI-E 1000/N

4.0 3.4 3.0 4.0 3.6 4.0 3.4 9.5

440 380 250 420 360 400 380 1000

45 4) 35 4) 32 4) 45 4) 35 4) 45 4) 35 4) 85 4)

2 2 2 2 2 2 2 2

42000 34000 19000 34000 26000 40000 34000 100000

95 90 78 79 72 91 90 95

65 65 90 90 90 65 65 65

4000 4600 5200 5200 5700 3800 4400 3800

h45 h45 universal13) universal universal h45 h45 h45

0.8 1.0 1.2 1.8 3.0 4.4

50 70 100 150 250 400

10 4) 12 4) 12 4) 20 4) 32 4) 45 4)

2 2 2 2 2 2

3800 6300 10200 17000 31100 55500

76 90 102 113 124 139

≤ 25 ≤ 25 ≤ 25 ≤ 25 ≤ 25 ≤ 25

2000 2000 2000 2000 2000 2000

universal universal universal universal universal universal

0.8 1.0 1.8 3.0 4.4

50 70 150 250 400

10 4) 12 4) 20 4) 32 4) 45 4)

2 2 2 2 2

3500 5600 14500 27000 48000

70 80 97 108 120

≤ 25 ≤ 25 ≤ 25 ≤ 25 ≤ 25

2000 2000 2000 2000 2000

universal universal universal universal universal

1 1

3500 5600

70 80

≤ 25 ≤ 25

2000 2000

universal universal

VIALOX® NAV®-E SUPER 4Y® NAV-E 50 SUPER 4Y 1) NAV-E 70 SUPER 4Y 1) NAV-E 100 SUPER 4Y 15) NAV-E 150 SUPER 4Y 15) NAV-E 250 SUPER 4Y 15) NAV-E 400 SUPER 4Y 15)

VIALOX® NAV®-E 4Y® NAV-E 50 4Y NAV-E 70 4Y NAV-E 150 4Y NAV-E 250 4Y NAV-E 400 4Y

VIALOX® NAV®-E 4Y®, with integrated ignition unit NAV-E 50/I 4Y 7) 16) NAV-E 70/I 4Y 7) 16)

0.8 1.0

50 70

10 4) 12 4)

1) In preparation 2) Operate on NAV® control gear 3) Operate only on electronic control gear 4) Typical value at rated voltage and cos φ ≥ 0.9 5) For the horizontal burning position, mount the holder so that the lamp electrodes are not arranged one on top of the other 6) Axial luminous intensity cd 7) Operate only with NAV® control gear 8) Operate only on 12.2 A control gear 9) Operate only on suitable hot restart igniters with an ignition voltage of up to 25 kV 10) Operate with HQI® control gear 11) Lamps ignite at an ignition voltage of 0.9 to 1.3 kVs. Lamps must not be operated with 4 to 5 kV igniters 12) Operation without an external igniter 13) Color shifts are possible in the base-down burning position 14) Lamps ignite at an ignition voltage of 0.56 to 1 kVs; lamps must not be operated with an ignition voltage >1.5 kVs 15) Important: Before replacing for NAV® standard lamps in existing installations, check that the igniters are suitable 16) No igniter required 17) Lamps require igniters with an ignition voltage of 4 to 5 kVs 18) Value resulting from operating the lamp with a high-reactance transformer 19) No control gear or igniters required 20) Operate on HQL® control gear 21) For circuit diagrams see page 6.54 22) See operating instructions: “Photometric and electrical data”

6.47