Technical data Product reference
Lamp current A
Lamp wattage W
Compensation capacitor at 50 Hz μF
Circuit Luminous diaflux lm gram no. 21)
Luminous efficacy lm/W
Color rendering Ra
Color temperature K
Burning position 22)
6600 6600 7700 7700 12000 12000
85 85 77 77 80 80
70 80 70 80 70 80
3000 4200 3000 4200 3000 4200
universal universal universal universal universal universal
6200 6200 7300 7300 11400 11400 17000 31000 25000
79 79 73 73 76 76 71 74 71
70 80 70 85 70 86 90 90 90
3000 4200 3000 4200 3000 4200 5200 5000 5200
universal universal universal universal universal universal universal universal universal
POWERSTAR® HQI®-E/P, clear, for open and enclosed fixtures HQI-E/P 70/WDL clear HQI-E/P 70/NDL clear HQI-E/P 100/WDL clear HQI-E/P 100/NDL clear HQI-E/P 150/WDL clear HQI-E/P 150/NDL clear
0.9 0.9 1.2 1.2 1.8 1.8
78 78 100 100 150 150
12 4) 12 4) 12 4) 12 4) 20 4) 20 4)
2/7 2/7 2/7 2/7 2/7 2/7
POWERSTAR® HQI®-E/P, coated, for open and enclosed fixtures HQI-E/P 70/WDL coated HQI-E/P 70/NDL coated HQI-E/P 100/WDL coated HQI-E/P 100/NDL coated HQI-E/P 150/WDL coated HQI-E/P 150/NDL coated HQI-E/P 250/D coated 2) HQI-E/P 400/D coated 2) HQI-E/P 400/D coated 10)
0.9 0.9 1.2 1.2 1.8 1.8 3.0 3.9 3.5
78 78 100 100 150 150 250 420 380
12 4) 12 4) 12 4) 12 4) 20 4) 20 4) 32 4) 45 4) 35 4)
2/7 2/7 2/7 2/7 2/7 2/7 2 2 2
POWERSTAR® HQI®-E, clear and coated, for enclosed fixtures HQI-E 400/N CLEAR 2) HQI-E 400/N CLEAR 10) HQI-E 250/D PRO 2) HQI-E 400/D PRO 2) HQI-E 400/D 10) HQI-E 400/N 2) HQI-E 400/N 10) HQI-E 1000/N
4.0 3.4 3.0 4.0 3.6 4.0 3.4 9.5
440 380 250 420 360 400 380 1000
45 4) 35 4) 32 4) 45 4) 35 4) 45 4) 35 4) 85 4)
2 2 2 2 2 2 2 2
42000 34000 19000 34000 26000 40000 34000 100000
95 90 78 79 72 91 90 95
65 65 90 90 90 65 65 65
4000 4600 5200 5200 5700 3800 4400 3800
h45 h45 universal13) universal universal h45 h45 h45
0.8 1.0 1.2 1.8 3.0 4.4
50 70 100 150 250 400
10 4) 12 4) 12 4) 20 4) 32 4) 45 4)
2 2 2 2 2 2
3800 6300 10200 17000 31100 55500
76 90 102 113 124 139
≤ 25 ≤ 25 ≤ 25 ≤ 25 ≤ 25 ≤ 25
2000 2000 2000 2000 2000 2000
universal universal universal universal universal universal
0.8 1.0 1.8 3.0 4.4
50 70 150 250 400
10 4) 12 4) 20 4) 32 4) 45 4)
2 2 2 2 2
3500 5600 14500 27000 48000
70 80 97 108 120
≤ 25 ≤ 25 ≤ 25 ≤ 25 ≤ 25
2000 2000 2000 2000 2000
universal universal universal universal universal
1 1
3500 5600
70 80
≤ 25 ≤ 25
2000 2000
universal universal
VIALOX® NAV®-E SUPER 4Y® NAV-E 50 SUPER 4Y 1) NAV-E 70 SUPER 4Y 1) NAV-E 100 SUPER 4Y 15) NAV-E 150 SUPER 4Y 15) NAV-E 250 SUPER 4Y 15) NAV-E 400 SUPER 4Y 15)
VIALOX® NAV®-E 4Y® NAV-E 50 4Y NAV-E 70 4Y NAV-E 150 4Y NAV-E 250 4Y NAV-E 400 4Y
VIALOX® NAV®-E 4Y®, with integrated ignition unit NAV-E 50/I 4Y 7) 16) NAV-E 70/I 4Y 7) 16)
0.8 1.0
50 70
10 4) 12 4)
1) In preparation 2) Operate on NAV® control gear 3) Operate only on electronic control gear 4) Typical value at rated voltage and cos φ ≥ 0.9 5) For the horizontal burning position, mount the holder so that the lamp electrodes are not arranged one on top of the other 6) Axial luminous intensity cd 7) Operate only with NAV® control gear 8) Operate only on 12.2 A control gear 9) Operate only on suitable hot restart igniters with an ignition voltage of up to 25 kV 10) Operate with HQI® control gear 11) Lamps ignite at an ignition voltage of 0.9 to 1.3 kVs. Lamps must not be operated with 4 to 5 kV igniters 12) Operation without an external igniter 13) Color shifts are possible in the base-down burning position 14) Lamps ignite at an ignition voltage of 0.56 to 1 kVs; lamps must not be operated with an ignition voltage >1.5 kVs 15) Important: Before replacing for NAV® standard lamps in existing installations, check that the igniters are suitable 16) No igniter required 17) Lamps require igniters with an ignition voltage of 4 to 5 kVs 18) Value resulting from operating the lamp with a high-reactance transformer 19) No control gear or igniters required 20) Operate on HQL® control gear 21) For circuit diagrams see page 6.54 22) See operating instructions: “Photometric and electrical data”
6.47