SWITCHGEAR R ANGE


Consumer Unit 1. 2. 3. 4. 5. 6. 7. 8.

Conforms to IEC 60439-3 Steel Enclosure IP31 (IP65 available upon request) Phosphate pretreated; electrostatic polyester powder _Nish Max load current: 125A, Max 600Vac Single phase: 120/240V AC 50/60Hz Incomer 2P Main Switch, MCB, RCD Outgoing device rating max 63A Single phase; 6, 9, 12, 14, 16, and 18 way

Row Distribution Boards 1. 2. 3. 4. 5. 6. 7. 8.

Conforms to DIN 43871 and BS 5486 part 12 standards Steel Enclosure IP31 Phosphate pretreated; electrostatic polyester powder _nish 12mod, 16mod & 21mods width with 1 to 6 Rows Built in symmetrical DIN 35 mm Top and bottom with knockouts Door is _ush with the cover Comb Busbar, Neutral & Earth Terminal can be provided

MCB Distribution Boards 1. 2. 3. 4. 5. 6. 7. 8.

Conforms to IEC 60439-3 ASTA citied Form 3b type 1 Steel Enclosure IP31 (IP65 on request) Phosphate pretreated; electrostatic polyester powder _Nish Max load current: 250A, Max 600Vac Three phase: 240/415V AC 50/60Hz Incomer 3/4P Main Switch, MCCB, MCB, RCD Outgoing device rating max 63A Available in 6 sizes: 4, 6, 8, 12, 14 or 18 3P MCB outgoing ways

MCCB Panel Boards 630A 36Ka 1. 2. 3. 4. 5. 6. 7. 8.

Conforms to IEC 60439-3 ASTA/CESI citied Form 3b type 1 Steel Enclosure IP31 (IP65 available upon request) Phosphate pretreated; electrostatic polyester powder _knish Factory built assembly with 630A TP Tinned Copper Busbar Three phase: 240/415V AC 50/60Hz Incomer 3/4P Main Switch, MCCB up to 630A Outgoing device rating max 125A Available in 5 sizes: 4, 6, 8, 12 and 16 3P MCCB ways


Motor Control Centers (MCCs) 1. 2. 3. 4.

5. 6. 7. 8. 9.

Modular sheet steel construction uto IP65 Citied Bus Bar systems 2500A (50kA for 1 sec as standard) Separation: Form 4 Type 2 standard (Types 3, 6, and 7 also available) Floor standing Ingress protection up to IP65 Top/bottom cable entry - front/rear cabling access Fixed, plug in or withdraw able type Contactor, soft start and variable speed drives BMS interface available Special control systems to customerâ‚Źsrequirements

Power Factor Correction Panels (PFC) 1. 2.

3. 4. 5.

Eliminates waste in electricity consumption Improves performance of your electrical equipment Reduces electricity costs by eliminating or reducing power factor charges Increases the level of operation loads by using electricity more efficiently Improves transformer and distribution system capacity

Synchronizing & Generator Control Panels Generator Synchronizing panels are designed to provide both a manual and an automatic synchronizing function for one generator or multiple generator breakers. Digital Frequency meters and volt-meters provide both generator and bus measurements. An operator is assisted during manual Synchronizing by both a synchroscope and synchronizing lights

Control Desk Control Desks are the brains of Electrical & Electronic Controls where the complete data of a plant is available for monitoring and operations. The equipment mentioned above is located in a manner of highest ease for the operation sta_. The controls are designed for self diagnostics, fault analysis, operation management and Data Logging


Instrumentation Panels 1. 2. 3. 4.

Custom designed to meet your application Steel Enclosure IP54, IP55, and IP65 (NEMA rating possible) Phosphate pretreated; electrostatic polyester powder _Nish Instrumentation for Temperature, Pressure, Flow, Conductivity/ Resistivity and Level recording 5. Deferent Visual Audible Alarm indicators 6. Complete drawing package with electrical schematics and Panel layouts 7. Complete operational and safety test before shipment

Package Substation (Indoor / Outdoor) 1. Common skid for all equipment 2. Housing fabricated from high quality electro-galvanized steel or Aluminum sand witched panel with sloping double roof removable canopy Segregated compartments 3. Separate doors for individual compartments 4. Polyester powder coated paint _Nish 5. Transformers: Oil immersed or Dry type 6. SF6 Insulated Ring Main Units & LV Switchgear


Auto Transfer Switches 1. 2. 3. 4. 5. 6.

Full range of ATS from 100 Amps to 4000 Amps Steel Enclosure IP54 unto IP65 Phosphate pretreated; electrostatic polyester powder _nishing Molded Case Circuit Breakers or Contactors Electrical & Mechanical interlocking Solid state voltage sensing relays

19 Inch Rack System for Networking F NP

1. 2. 3. 4. 5. 6.

19• Enclosures for networking & telecoms Modern stylish appearance, rugged construction Available in height ranging from 24-46u Two standard depths: 600 & 800 mm Front tempered glass door complete with lock Metal vented rear door complete with lock 7. Polyester powder coated paint _nish


LV Distribution Panels & Feeder Pillars 1. LV Panels are rated up to 3000 Amps/415V AC 2. Feeder Pillars are rated unto 800 Amps 3. These comprise of a free standing enclosure, tinned copper bus bars, OFF load incomer Isolators, and outgoing distribution unit ways like 3-Pole vertical fuse strip suitable for DIN type NH fuse links or for BS type ‚J€ HRC fuse links

Street Lighting Control Panels Application of switching street lights ON & OFF automatically or manually. These panels comprise of an Aluminums enclosure, MCCBs/ELCBs, Main Contactors, kWh meter, Astronomical Timer, Photocell, and a Control Switch for override functions

Testing Facility Our modern lab is equipped with the latest Testing Equipment: 1. FREJA 300 ƒ Relay Testing Set 2. Sverker 760 ƒ Secondary Current Injection Set 3. ODEN-AT ƒ Primary Current Injection Set 4. Circuit Breaker Analyzer Set 5. AC High Voltage Test Set (0-40-50KV) 6. DC High Voltage Test Set (0-50-75KV) 7. AC High Voltage Test Set (0-5KV) 8. DUCATI ƒ Energy Analyzer 9. 5KV Insulation Tester (Digital-Magger)

Generator AMF Panels In these panels, the Mains/ Electricity Board supply is monitored and in case of failure the Genset will start automatically and the load will be transferred to the Genset. When the Mains supply is restored, the load will be transferred back and the Genest will be shut down after a short cooling down period

F NP


Stainless Steel Consoles 1. 2. 3. 4.

5. 6. 7. 8.

Console with sloping top and sloping upper lid Hidden hinges & gas strut Double depth adjustable mounting plate Gland plate & eyebolts on the top Material: Unpainted brushed stainless steel AISI 304 & 316 Ingress Protection: IP54 Colour: Natural Sizes: 15 sizes available from 600mm to 2000mm width

Double Wall Mounting Aluminum Enclosures 1. Double Wall construction is fully ventilated 2. Free _ow air tubes are placed between the outer and inner walls and thus the interior temperature is remarkably lower than in the Single Wall Enclosure 3. Ventilated doors, walls & detachable Canopy 4. Plinth is in-built or available separately 5. Ingress Protection: IP55 6. Finish: Polyester powder coating RAL7032 7. Sizes: 15 sizes from 1000H x 600W x 300D (mm) to 2000H x 1400W x 600D (mm)

Wall Mounting Stainless Steel Enclosures 1. Stainless steel AISI 316 enclosures with 1 or 2. 2 door latches depending on size No gland plate openings with galvanised steel or Stainless steel mounting plate 3. Ingress Protection: IP54 4. Finish: Unpainted brushed stainless steel 5. Colour: Natural 6. Sizes: 31 sizes from 200x300x150mm to 1200x1000x300mm


CABLE TRAY SYSTEM


U-Style

H-Style


LADDER TYPE

PERFORATED TYPE

SOLID BOTTOM TYPE


Perforated & Solid Cable Tray - Fittings, Covers, & Accessories Accessories See pages 8 - 9

Fittings See pages 10 - 21 Fitting Covers See page 23


Perforated & Solid Cable Tray - Straight Sections Straight Section Part Numbering - 25mm Height Example: P 025 V C P 15 SS - 200 - 3000 - SA

Tray Type

P= (Perforated & Solid Cable Tray)

Height

Bottom Type

025 = 25mm

S = Solid V = Perforated

Return Flange Type

C = 90°

(Southern Asia)

Material

Thickness

Type

Width

Length

P = Pre-Galv G = HDGAF SS6 = Stainless Type 316

10 * = 1.0mm 15 = 1.5mm 20 = 2.0mm

SS = Straight Section

050 = 50mm 100 = 100mm 150 = 150mm 200 = 200mm 300 = 300mm 400 = 400mm 500 = 500mm 600 = 600mm

3000 = 3000mm

* 1.0mm thickness is only available in widths up to and including 300 (300mm). Splice plates not supplied with straight sections. Order standard splice plates separately from page 8. One (1) pair required to connect to system.

90° Return Flange (C) with Solid Bottom (S)

90° Return Flange (C) with Perforated Bottom (V)

Notes: Perforated slot dimensions and patterns may vary depending on tray size and type. The 180° return flange is not available on 025 tray heights.

Length

Length

Width

Width

Perforated & Solid Cable Tray Dimensional Drawing - Tray Height 25mm 90° Return Flange (C) 25

Width Thickness


Perforated & Solid Cable Tray - Straight Sections Straight Section Part Numbering - 50mm Height Example: P 050 V C P 15 SS - 200 - 3000 - SA

Tray Type

P= (Perforated & Solid Cable Tray)

Height

Bottom Type

Return Flange Type

050 = 50mm

S = Solid V = Perforated

R = 180° C = 90°

(Southern Asia)

Material

Thickness

Type

Width

Length

P = Pre-Galv G = HDGAF SS6 = Stainless Type 316

10 * = 1.0mm 15 = 1.5mm 20 = 2.0mm

SS = Straight Section

050 = 50mm 100 = 100mm 150 = 150mm 200 = 200mm 300 = 300mm 400 = 400mm 500 = 500mm 600 = 600mm 900 = 900mm

3000 = 3000mm

* 1.0mm thickness is only available in widths up to and including 300 (300mm). Splice plates not supplied with straight sections. Order standard splice plates separately from page 8. One (1) pair required to connect to system.

180° Return Flange (R) with Solid Bottom (S)

90° Return Flange (C) with Perforated Bottom (V)

Note: Perforated slot dimensions and patterns may vary depending on tray size and type.

Length

Length

Width

Width

Perforated & Solid Cable Tray Dimensional Drawing - Tray Height 50mm 180° Return Flange (R)

90° Return Flange (C) 50 7 x 15 typ.

50 7 x 15 typ.

25

Width 50

25

25

Width 50

Thickness 25

Thickness


Perforated & Solid Cable Tray - Straight Sections Straight Section Part Numbering - 75mm Height Example: P 075 V C P 15 SS - 200 - 3000 - SA

Tray Type

P= (Perforated & Solid Cable Tray)

Height

Bottom Type

Return Flange Type

075 = 75mm

S = Solid V = Perforated

R = 180° C = 90°

(Southern Asia)

Material

Thickness

Type

Width

Length

P = Pre-Galv G = HDGAF SS6 = Stainless Type 316

10 * = 1.0mm 15 = 1.5mm 20 = 2.0mm

SS = Straight Section

100 = 100mm 150 = 150mm 200 = 200mm 300 = 300mm 400 = 400mm 500 = 500mm 600 = 600mm 900 = 900mm

3000 = 3000mm

* 1.0mm thickness is only available in widths up to and including 300 (300mm). Splice plates not supplied with straight sections. Order standard splice plates separately from page 8. One (1) pair required to connect to system.

180° Return Flange (R) with Solid Bottom (S)

90° Return Flange (C) with Perforated Bottom (V)

Note: Perforated slot dimensions and patterns may vary depending on tray size and type.

Length

Length

Width

Width

Perforated & Solid Cable Tray Dimensional Drawing - Tray Height 75mm 90° Return Flange (C)

180° Return Flange (R) 50

50 7 x 15 typ.

25

75 37.5

7 x 15 typ.

Width

25

Width

75

Thickness 37.5

Thickness


Perforated & Solid Cable Tray - Straight Sections Straight Section Part Numbering - 100mm Height Example: P 100 V C P 15 SS - 200 - 3000 - SA

Tray Type

P= (Perforated & Solid Cable Tray)

Height

Bottom Type

Return Flange Type

100 = 100mm

S = Solid V = Perforated

R = 180° C = 90°

(Southern Asia)

Material

Thickness

Type

Width

Length

P = Pre-Galv G = HDGAF SS6 = Stainless Type 316

10 * = 1.0mm 15 = 1.5mm 20 = 2.0mm

SS = Straight Section

100 = 100mm 150 = 150mm 200 = 200mm 300 = 300mm 400 = 400mm 500 = 500mm 600 = 600mm 900 = 900mm

3000 = 3000mm

* 1.0mm thickness is only available in widths up to and including 300 (300mm). Splice plates not supplied with straight sections. Order standard splice plates separately from page 8. One (1) pair required to connect to system.

180° Return Flange (R) with Solid Bottom (S)

90° Return Flange (C) with Perforated Bottom (V)

Note: Perforated slot dimensions and patterns may vary depending on tray size and type.

Length

Length

Width

Width

Perforated & Solid Cable Ladder Dimensional Drawing - Side Rail Height 100mm 180° Return Flange (R) 7 x 15 typ.

50

25

100

50

90° Return Flange (C) 50 7 x 15 typ.

Width

25

Thickness

100

50

Width

Thickness


Perforated & Solid Cable Tray - Accessories Bottom Splice Plates (Mounted on bottom of 025 height trays as splice plates and can also be used to stabilize tray connections on other heights) (Sold Individually With Hardware) • ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316

Trays

Trays

Trays

Splice Plate

Splice Plate

PBS**-1-SA

Part Number PBS **-1-SA PBS **-2-SA PBS **-3-SA PBS **-4-SA PBS **-5-SA PBS **-6-SA

Tray Widths Plate Width Number of Holes 50 100 150 - 300 400 - 500 600 900

44 94 144 194 394 594

2 4 4 4 6 6

Splice Plate

PBS**-2-SA PBS**-3-SA PBS**-4-SA

PBS**-5-SA PBS**-6-SA

Side Splice Plates (Mounted inside of tray)

Expansion Splice Plates (Mounted inside of tray)

(Sold in Pairs With Hardware) • ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316

(Sold in Pairs With Hardware) • ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316

Part Number

Tray Height

Part Number

Tray Height

PSP050**-SA PSP075**-SA PSP100**-SA

50 75 100

PEP050**-SA PEP075**-SA PEP100**-SA

50 75 100

Horizontal Adjustable Splice Plates (Mounted inside of tray) (Sold in Pairs With Hardware) • ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316 • Requires mitering of trays and drilling new splice plate holes on inside angle

Vertical Adjustable Splice Plates (Mounted inside of tray) (Sold in Pairs With Hardware) • ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316

Miter 1/2 the required angle on each tray end

Part Number

Tray Height

PHA050**-SA PHA075**-SA PHA100**-SA

50 75 100

angle

Example: 40° bend requires 20° miter each end

Part Number

Tray Height

PVA050**-SA PVA075**-SA PVA100**-SA

50 75 100


Perforated & Solid Cable Tray - Accessories Right/Left Reducer Splice Plates (Mounted inside of tray)

Wrap-Around Cover Clamps

(Sold as a Set With Hardware) • ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316 • __ Width: Insert width difference between the two trays

(Sold Individually With Hardware) • ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316 • __ Insert Tray Width of 050 = 50mm, 100 = 100mm, 150 = 150mm, 200 = 200mm, 300 = 300mm, 400 = 400mm, 500 = 500mm, 600 = 600mm, 900 = 900mm

Part Number

Tray Height

PLR050**__-SA PLR075**__-SA PLR100**__-SA

50 75 100

Straight Reducer Splice Plates (Mounted inside of tray) (Sold as a Set With Hardware) • ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316 • __ Width: Insert one half the width difference between the two trays

Part Number

Tray Height

PSR050**__-SA PSR075**__-SA PSR100**__-SA

50 75 100

Part Number

Tray Height

PWCC025**__-SA PWCC050**__-SA PWCC075**__-SA PWCC100**__-SA

25 * 50 75 100

* Is not available in 900mm wide tray

C-Shape Cover Clamps Hold Downs - For (R) & (C) Flanges

(Sold in Pairs With Hardware) • ** Insert G for Hot Dip Galvanized, SS6 for Stainless Steel 316

(Sold in Pairs Without Hardware) • ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316 • Not recommended for use with covers

Part Number

Tray Height

Part Number

Tray Height

PHD025**-SA PHD050**-SA PHD075**-SA PHD100**-SA

25 50 75 100

PCCC025**-SA PCCC050**-SA PCCC075**-SA PCCC100**-SA

25 50 75 100


Perforated & Solid Cable Tray - Fittings Cable Tray Fittings are designed to support cables as they transition directions. Note: Perforated slot dimensions and patterns may vary depending on tray size and type. All fitting bottom are shown as solid bottoms. Perforated bottoms are available.

HB Horizontal Bend

HT Horizontal Tee

HX Horizontal Cross

(C) Formed Shown

(R) Mitered Shown

(C) Formed Shown

LR Right Reducer

SR Straight Reducer

RR Left Reducer

(C) Mitered Only

(R) Mitered Only

(C) Mitered Only

Splice Plate Holes Fittings engineered with 100mm tangents for splicing integrity.

VI Vertical Inside Bend (R) Formed Only

50 7 x 15 typ.

VO Vertical Outside Bend

25 1/2

The Tray Height

(C) Formed Only

Note: Fittings with 25mm tray heights do not have splice plate holes in the rails.

Fittings Part Numbering Prefix

Example: P F 050 V R SS6 10 HB - 200 - 60 R600 - SA (Southern Asia)

Tray Type

Radius Detail

P=

F= Formed M= Mitered

(Perforated & Solid Cable Tray)

Height

025 = 25mm 050 = 50mm 075 = 75mm 100 = 100mm

Bottom Type

S= Solid V= Perforated

Return Flange Type

Angle † Material

Thickness

R = 180° ††† P = Pre-Galv 10 * = 1.0mm C = 90° G = HDGAF 15 = 1.5mm SS6 = Stainless 20 = 2.0mm Type 316

Type

HB HT † HX † VO *** VI *** RR † LR † SR †

(°)

Radius

050 = 50mm D 30 100 = 100mm 45 150 = 150mm 60 200 = 200mm 90 300 = 300mm 400 = 400mm 500 = 500mm 600 = 600mm 900 = 900mm †††

R300 = 300mm R600 = 600mm R900 = 900mm

Width


Perforated & Solid Cable Tray - Fittings Horizontal Bends 90° (HB)

Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180° return flange not available on 025 tray heights.

Hole Pattern

Splice plates not supplied with fittings. Order standard splice plates separately from page 8. One (1) pair required to connect to system.

90˚ Horizontal Bend Formed (C) Rail Shown

90˚ Horizontal Bend Mitered (R) Rail Shown

R 100

R 100

B

100 W

W

A

Bend Tray Radius Width R W mm

300

600

900

mm

50 100 150 200 300 400 500 600 900 50 100 150 200 300 400 500 600 900 50 100 150 200 300 400 500 600 900

B

100 A

90˚ Horizontal Bend Dimensions Formed Radius Fittings A Catalog No. mm PF(Prefix)HB-050-90R300-SA PF(Prefix)HB-100-90R300-SA PF(Prefix)HB-150-90R300-SA PF(Prefix)HB-200-90R300-SA PF(Prefix)HB-300-90R300-SA PF(Prefix)HB-400-90R300-SA PF(Prefix)HB-500-90R300-SA PF(Prefix)HB-600-90R300-SA PF(Prefix)HB-900-90R300-SA PF(Prefix)HB-050-90R600-SA PF(Prefix)HB-100-90R600-SA PF(Prefix)HB-150-90R600-SA PF(Prefix)HB-200-90R600-SA PF(Prefix)HB-300-90R600-SA PF(Prefix)HB-400-90R600-SA PF(Prefix)HB-500-90R600-SA PF(Prefix)HB-600-90R600-SA PF(Prefix)HB-900-90R600-SA PF(Prefix)HB-050-90R900-SA PF(Prefix)HB-100-90R900-SA PF(Prefix)HB-150-90R900-SA PF(Prefix)HB-200-90R900-SA PF(Prefix)HB-300-90R900-SA PF(Prefix)HB-400-90R900-SA PF(Prefix)HB-500-90R900-SA PF(Prefix)HB-600-90R900-SA PF(Prefix)HB-900-90R900-SA

450 500 550 600 700 800 900 1000 1300 750 800 850 900 1000 1100 1200 1300 1600 1050 1100 1150 1200 1300 1400 1500 1600 1900

B mm

450 500 550 600 700 800 900 1000 1300 750 800 850 900 1000 1100 1200 1300 1600 1050 1100 1150 1200 1300 1400 1500 1600 1900

Mitered Radius Fittings A Catalog No. mm PM(Prefix)HB-050-90R300-SA PM(Prefix)HB-100-90R300-SA PM(Prefix)HB-150-90R300-SA PM(Prefix)HB-200-90R300-SA PM(Prefix)HB-300-90R300-SA PM(Prefix)HB-400-90R300-SA PM(Prefix)HB-500-90R300-SA PM(Prefix)HB-600-90R300-SA PM(Prefix)HB-900-90R300-SA PM(Prefix)HB-050-90R600-SA PM(Prefix)HB-100-90R600-SA PM(Prefix)HB-150-90R600-SA PM(Prefix)HB-200-90R600-SA PM(Prefix)HB-300-90R600-SA PM(Prefix)HB-400-90R600-SA PM(Prefix)HB-500-90R600-SA PM(Prefix)HB-600-90R600-SA PM(Prefix)HB-900-90R600-SA PM(Prefix)HB-050-90R900-SA PM(Prefix)HB-100-90R900-SA PM(Prefix)HB-150-90R900-SA PM(Prefix)HB-200-90R900-SA PM(Prefix)HB-300-90R900-SA PM(Prefix)HB-400-90R900-SA PM(Prefix)HB-500-90R900-SA PM(Prefix)HB-600-90R900-SA PM(Prefix)HB-900-90R900-SA

450 500 550 600 700 800 900 1000 1300 750 800 850 900 1000 1100 1200 1300 1600 1050 1100 1150 1200 1300 1400 1500 1600 1900

B mm

450 500 550 600 700 800 900 1000 1300 750 800 850 900 1000 1100 1200 1300 1600 1050 1100 1150 1200 1300 1400 1500 1600 1900


Perforated & Solid Cable Tray - Fittings

Need Hole Pattern

Horizontal Bends 60° (HB)

Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180° return flange not available on 025 tray heights.

Splice plates not supplied with fittings. Order standard splice plates separately from page 8. One (1) pair required to connect to system.

60˚ Horizontal Bend Formed (C) Shown

60˚ Horizontal Bend Mitered (R) Shown 100

100

B

R

100

100 W

Bend Tray Radius Width R W mm

300

600

900

mm

50 100 150 200 300 400 500 600 900 50 100 150 200 300 400 500 600 900 50 100 150 200 300 400 500 600 900

B

R

W

A

A

60˚ Horizontal Bend Dimensions Formed Radius Fittings A Catalog No. mm PF(Prefix)HB-050-60R300-SA PF(Prefix)HB-100-60R300-SA PF(Prefix)HB-150-60R300-SA PF(Prefix)HB-200-60R300-SA PF(Prefix)HB-300-60R300-SA PF(Prefix)HB-400-60R300-SA PF(Prefix)HB-500-60R300-SA PF(Prefix)HB-600-60R300-SA PF(Prefix)HB-900-60R300-SA PF(Prefix)HB-050-60R600-SA PF(Prefix)HB-100-60R600-SA PF(Prefix)HB-150-60R600-SA PF(Prefix)HB-200-60R600-SA PF(Prefix)HB-300-60R600-SA PF(Prefix)HB-400-60R600-SA PF(Prefix)HB-500-60R600-SA PF(Prefix)HB-600-60R600-SA PF(Prefix)HB-900-60R600-SA PF(Prefix)HB-050-60R900-SA PF(Prefix)HB-100-60R900-SA PF(Prefix)HB-150-60R900-SA PF(Prefix)HB-200-60R900-SA PF(Prefix)HB-300-60R900-SA PF(Prefix)HB-400-60R900-SA PF(Prefix)HB-500-60R900-SA PF(Prefix)HB-600-60R900-SA PF(Prefix)HB-900-60R900-SA

287 337 387 437 537 637 737 837 1137 437 487 537 587 687 787 887 987 1287 587 637 687 737 837 967 1037 1137 1437

B mm

453 496 540 583 670 756 843 929 1189 713 756 800 843 929 1016 1103 1189 1449 973 1016 1053 1103 1189 1276 1362 1449 1709

Mitered Radius Fittings A Catalog No. mm PM(Prefix)HB-050-60R300-SA PM(Prefix)HB-100-60R300-SA PM(Prefix)HB-150-60R300-SA PM(Prefix)HB-200-60R300-SA PM(Prefix)HB-300-60R300-SA PM(Prefix)HB-400-60R300-SA PM(Prefix)HB-500-60R300-SA PM(Prefix)HB-600-60R300-SA PM(Prefix)HB-900-60R300-SA PM(Prefix)HB-050-60R600-SA PM(Prefix)HB-100-60R600-SA PM(Prefix)HB-150-60R600-SA PM(Prefix)HB-200-60R600-SA PM(Prefix)HB-300-60R600-SA PM(Prefix)HB-400-60R600-SA PM(Prefix)HB-500-60R600-SA PM(Prefix)HB-600-60R600-SA PM(Prefix)HB-900-60R600-SA PM(Prefix)HB-050-60R900-SA PM(Prefix)HB-100-60R900-SA PM(Prefix)HB-150-60R900-SA PM(Prefix)HB-200-60R900-SA PM(Prefix)HB-300-60R900-SA PM(Prefix)HB-400-60R900-SA PM(Prefix)HB-500-60R900-SA PM(Prefix)HB-600-60R900-SA PM(Prefix)HB-900-60R900-SA

287 337 387 437 537 637 737 837 1137 437 487 537 587 687 787 887 987 1287 587 637 687 737 837 967 1037 1137 1437

B mm

453 496 540 583 670 756 843 929 1189 713 756 800 843 929 1016 1103 1189 1449 973 1016 1053 1103 1189 1276 1362 1449 1709


Perforated & Solid Cable Tray - Fittings Need Hole Pattern

Horizontal Bends 45° (HB)

Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180° return flange not available on 025 tray heights.

Splice plates not supplied with fittings. Order standard splice plates separately from page 8. One (1) pair required to connect to system.

45˚ Horizontal Bend Formed (C) Shown

45˚ Horizontal Bend Mitered (R) Shown

100

100

B

R

R

100

100 W

W A

Bend Tray Radius Width R W mm

300

600

900

mm

50 100 150 200 300 400 500 600 900 50 100 150 200 300 400 500 600 900 50 100 150 200 300 400 500 600 900

B

A

45˚ Horizontal Bend Dimensions Formed Radius Fittings A Catalog No. mm PF(Prefix)HB-050-45R300-SA PF(Prefix)HB-100-45R300-SA PF(Prefix)HB-150-45R300-SA PF(Prefix)HB-200-45R300-SA PF(Prefix)HB-300-45R300-SA PF(Prefix)HB-400-45R300-SA PF(Prefix)HB-500-45R300-SA PF(Prefix)HB-600-45R300-SA PF(Prefix)HB-900-45R300-SA PF(Prefix)HB-050-45R600-SA PF(Prefix)HB-100-45R600-SA PF(Prefix)HB-150-45R600-SA PF(Prefix)HB-200-45R600-SA PF(Prefix)HB-300-45R600-SA PF(Prefix)HB-400-45R600-SA PF(Prefix)HB-500-45R600-SA PF(Prefix)HB-600-45R600-SA PF(Prefix)HB-900-45R600-SA PF(Prefix)HB-050-45R900-SA PF(Prefix)HB-100-45R900-SA PF(Prefix)HB-150-45R900-SA PF(Prefix)HB-200-45R900-SA PF(Prefix)HB-300-45R900-SA PF(Prefix)HB-400-45R900-SA PF(Prefix)HB-500-45R900-SA PF(Prefix)HB-600-45R900-SA PF(Prefix)HB-900-45R900-SA

209 259 309 359 459 559 659 759 1059 296 346 396 446 546 646 746 846 1146 384 434 484 534 634 734 834 934 1234

B mm

418 454 489 524 595 666 736 807 1019 630 666 701 736 807 878 949 1019 1231 842 878 913 949 1019 1090 1161 1231 1444

Mitered Radius Fittings A Catalog No. mm PM(Prefix)HB-050-45R300-SA PM(Prefix)HB-100-45R300-SA PM(Prefix)HB-150-45R300-SA PM(Prefix)HB-200-45R300-SA PM(Prefix)HB-300-45R300-SA PM(Prefix)HB-400-45R300-SA PM(Prefix)HB-500-45R300-SA PM(Prefix)HB-600-45R300-SA PM(Prefix)HB-900-45R300-SA PM(Prefix)HB-050-45R600-SA PM(Prefix)HB-100-45R600-SA PM(Prefix)HB-150-45R600-SA PM(Prefix)HB-200-45R600-SA PM(Prefix)HB-300-45R600-SA PM(Prefix)HB-400-45R600-SA PM(Prefix)HB-500-45R600-SA PM(Prefix)HB-600-45R600-SA PM(Prefix)HB-900-45R600-SA PM(Prefix)HB-050-45R900-SA PM(Prefix)HB-100-45R900-SA PM(Prefix)HB-150-45R900-SA PM(Prefix)HB-200-45R900-SA PM(Prefix)HB-300-45R900-SA PM(Prefix)HB-400-45R900-SA PM(Prefix)HB-500-45R900-SA PM(Prefix)HB-600-45R900-SA PM(Prefix)HB-900-45R900-SA

209 259 309 459 459 559 659 759 1059 296 346 396 446 546 646 746 846 1146 384 434 484 534 634 734 834 934 1234

B mm

418 454 489 595 595 666 736 807 1019 630 666 701 736 807 878 949 1019 1231 842 878 913 949 1019 1090 1161 1231 1444


Perforated & Solid Cable Tray - Fittings Horizontal Bends 30° (HB) Need Hole Pattern Splice plates not supplied with fittings. Order standard splice plates separately from page 8. One (1) pair required to connect to system.

Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180° return flange not available on 025 tray heights.

30˚ Horizontal Bend Formed (C) Shown

30˚ Horizontal Bend Mitered )R) Shown

100

100

R

B

R 100

100

W

W

A

A

Bend Tray Radius Width R W mm

300

600

900

mm

50 100 150 200 300 400 500 600 900 50 100 150 200 300 400 500 600 900 50 100 150 200 300 400 500 600 900

B

30˚ Horizontal Bend Dimensions Formed Radius Fittings A Catalog No. mm PF(Prefix)HB-050-30R300-SA PF(Prefix)HB-100-30R300-SA PF(Prefix)HB-150-30R300-SA PF(Prefix)HB-200-30R300-SA PF(Prefix)HB-300-30R300-SA PF(Prefix)HB-400-30R300-SA PF(Prefix)HB-500-30R300-SA PF(Prefix)HB-600-30R300-SA PF(Prefix)HB-900-30R300-SA PF(Prefix)HB-050-30R600-SA PF(Prefix)HB-100-30R600-SA PF(Prefix)HB-150-30R600-SA PF(Prefix)HB-200-30R600-SA PF(Prefix)HB-300-30R600-SA PF(Prefix)HB-400-30R600-SA PF(Prefix)HB-500-30R600-SA PF(Prefix)HB-600-30R600-SA PF(Prefix)HB-900-30R600-SA PF(Prefix)HB-050-30R900-SA PF(Prefix)HB-100-30R900-SA PF(Prefix)HB-150-30R900-SA PF(Prefix)HB-200-30R900-SA PF(Prefix)HB-300-30R900-SA PF(Prefix)HB-400-30R900-SA PF(Prefix)HB-500-30R900-SA PF(Prefix)HB-600-30R900-SA PF(Prefix)HB-900-30R900-SA

140 190 240 290 390 490 590 690 990 180 230 280 330 430 530 630 730 1030 221 271 321 371 471 571 671 771 1071

B mm

362 387 412 637 487 537 587 637 787 512 537 562 587 637 687 737 787 937 662 687 712 737 787 837 887 937 1087

Mitered Radius Fittings A Catalog No. mm PM(Prefix)HB-050-30R300-SA PM(Prefix)HB-100-30R300-SA PM(Prefix)HB-150-30R300-SA PM(Prefix)HB-200-30R300-SA PM(Prefix)HB-300-30R300-SA PM(Prefix)HB-400-30R300-SA PM(Prefix)HB-500-30R300-SA PM(Prefix)HB-600-30R300-SA PM(Prefix)HB-900-30R300-SA PM(Prefix)HB-050-30R600-SA PM(Prefix)HB-100-30R600-SA PM(Prefix)HB-150-30R600-SA PM(Prefix)HB-200-30R600-SA PM(Prefix)HB-300-30R600-SA PM(Prefix)HB-400-30R600-SA PM(Prefix)HB-500-30R600-SA PM(Prefix)HB-600-30R600-SA PM(Prefix)HB-900-30R600-SA PM(Prefix)HB-050-30R900-SA PM(Prefix)HB-100-30R900-SA PM(Prefix)HB-150-30R900-SA PM(Prefix)HB-200-30R900-SA PM(Prefix)HB-300-30R900-SA PM(Prefix)HB-400-30R900-SA PM(Prefix)HB-500-30R900-SA PM(Prefix)HB-600-30R900-SA PM(Prefix)HB-900-30R900-SA

140 190 240 290 390 490 590 690 990 180 230 280 330 430 530 630 730 1030 221 271 321 371 471 571 671 771 1071

B mm

362 387 412 637 487 537 587 637 787 512 537 562 587 637 687 737 787 937 662 687 712 737 787 837 887 937 1087


Perforated & Solid Cable Tray - Fittings Horizontal Tee (HT)

Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180째 return flange not available on 025 tray heights.

Splice plates not supplied with fittings. Order standard splice plates separately from page 8. Two (2) pair required to connect to system.

Horizontal Tee Formed (C) Shown

Horizontal Tee Mitered (R) Shown B

B

R

A 100 100

100 100

W

Bend Tray Radius Width R W mm

300

600

900

mm

50 100 150 200 300 400 500 600 900 50 100 150 200 300 400 500 600 900 50 100 150 200 300 400 500 600 900

R

A 100

100 W

Horizontal Tee Dimensions Formed Radius Fittings A Catalog No. mm PF(Prefix)HT-050-R300-SA PF(Prefix)HT-100-R300-SA PF(Prefix)HT-150-R300-SA PF(Prefix)HT-200-R300-SA PF(Prefix)HT-300-R300-SA PF(Prefix)HT-400-R300-SA PF(Prefix)HT-500-R300-SA PF(Prefix)HT-600-R300-SA PF(Prefix)HT-900-R300-SA PF(Prefix)HT-050-R600-SA PF(Prefix)HT-100-R600-SA PF(Prefix)HT-150-R600-SA PF(Prefix)HT-200-R600-SA PF(Prefix)HT-300-R600-SA PF(Prefix)HT-400-R600-SA PF(Prefix)HT-500-R600-SA PF(Prefix)HT-600-R600-SA PF(Prefix)HT-900-R600-SA PF(Prefix)HT-050-R900-SA PF(Prefix)HT-100-R900-SA PF(Prefix)HT-150-R900-SA PF(Prefix)HT-200-R900-SA PF(Prefix)HT-300-R900-SA PF(Prefix)HT-400-R900-SA PF(Prefix)HT-500-R900-SA PF(Prefix)HT-600-R900-SA PF(Prefix)HT-900-R900-SA

450 500 550 600 700 800 900 1000 1300 750 800 850 900 1000 1100 1200 1300 1600 1050 1100 1150 1200 1300 1400 1500 1600 1900

B mm

850 900 950 1000 1100 1200 1300 1400 1700 1450 1500 1550 1600 1700 1800 1900 2000 2300 2050 2100 2150 2200 2300 2400 2500 2600 2900

Mitered Radius Fittings A Catalog No. mm PM(Prefix)HT-050-R300-SA PM(Prefix)HT-100-R300-SA PM(Prefix)HT-150-R300-SA PM(Prefix)HT-200-R300-SA PM(Prefix)HT-300-R300-SA PM(Prefix)HT-400-R300-SA PM(Prefix)HT-500-R300-SA PM(Prefix)HT-600-R300-SA PM(Prefix)HT-900-R300-SA PM(Prefix)HT-050-R600-SA PM(Prefix)HT-100-R600-SA PM(Prefix)HT-150-R600-SA PM(Prefix)HT-200-R600-SA PM(Prefix)HT-300-R600-SA PM(Prefix)HT-400-R600-SA PM(Prefix)HT-500-R600-SA PM(Prefix)HT-600-R600-SA PM(Prefix)HT-900-R600-SA PM(Prefix)HT-050-R900-SA PM(Prefix)HT-100-R900-SA PM(Prefix)HT-150-R900-SA PM(Prefix)HT-200-R900-SA PM(Prefix)HT-300-R900-SA PM(Prefix)HT-400-R900-SA PM(Prefix)HT-500-R900-SA PM(Prefix)HT-600-R900-SA PM(Prefix)HT-900-R900-SA

450 500 550 600 700 800 900 1000 1300 750 800 850 900 1000 1100 1200 1300 1600 1050 1100 1150 1200 1300 1400 1500 1600 1900

B mm

850 900 950 1000 1100 1200 1300 1400 1700 1450 1500 1550 1600 1700 1800 1900 2000 2300 2050 2100 2150 2200 2300 2400 2500 2600 2900


Perforated & Solid Cable Tray - Fittings Horizontal Cross (HX)

Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180째 return flange not available on 025 tray heights.

Splice plates not supplied with fittings. Order standard splice plates separately from page 8. Three (3) pair required to connect to system.

Horizontal Cross Formed (C) Shown

Horizontal Cross Mitered (R) Shown

B

B

100 100

R

100 100

100

mm

300

600

900

mm

50 100 150 200 300 400 500 600 900 50 100 150 200 300 400 500 600 900 50 100 150 200 300 400 500 600 900

100 W

W

Bend Tray Radius Width R W

R

A

A

Horizontal Cross Dimensions Formed Radius Fittings A Catalog No. mm PF(Prefix)HX-050-R300-SA PF(Prefix)HX-100-R300-SA PF(Prefix)HX-150-R300-SA PF(Prefix)HX-200-R300-SA PF(Prefix)HX-300-R300-SA PF(Prefix)HX-400-R300-SA PF(Prefix)HX-500-R300-SA PF(Prefix)HX-600-R300-SA PF(Prefix)HX-900-R300-SA PF(Prefix)HX-050-R600-SA PF(Prefix)HX-100-R600-SA PF(Prefix)HX-150-R600-SA PF(Prefix)HX-200-R600-SA PF(Prefix)HX-300-R600-SA PF(Prefix)HX-400-R600-SA PF(Prefix)HX-500-R600-SA PF(Prefix)HX-600-R600-SA PF(Prefix)HX-900-R600-SA PF(Prefix)HX-050-R900-SA PF(Prefix)HX-100-R900-SA PF(Prefix)HX-150-R900-SA PF(Prefix)HX-200-R900-SA PF(Prefix)HX-300-R900-SA PF(Prefix)HX-400-R900-SA PF(Prefix)HX-500-R900-SA PF(Prefix)HX-600-R900-SA PF(Prefix)HX-900-R900-SA

450 500 550 600 700 800 900 1000 1300 750 800 850 900 1000 1100 1200 1300 1600 1050 1100 1150 1200 1300 1400 1500 1600 1900

B mm

850 900 950 1000 1100 1200 1300 1400 1700 1450 1500 1550 1600 1700 1800 1900 2000 2300 2050 2100 2150 2200 2300 2400 2500 2600 2900

Mitered Radius Fittings A Catalog No. mm PM(Prefix)HX-050-R300-SA PM(Prefix)HX-100-R300-SA PM(Prefix)HX-150-R300-SA PM(Prefix)HX-200-R300-SA PM(Prefix)HX-300-R300-SA PM(Prefix)HX-400-R300-SA PM(Prefix)HX-500-R300-SA PM(Prefix)HX-600-R300-SA PM(Prefix)HX-900-R300-SA PM(Prefix)HX-050-R600-SA PM(Prefix)HX-100-R600-SA PM(Prefix)HX-150-R600-SA PM(Prefix)HX-200-R600-SA PM(Prefix)HX-300-R600-SA PM(Prefix)HX-400-R600-SA PM(Prefix)HX-500-R600-SA PM(Prefix)HX-600-R600-SA PM(Prefix)HX-900-R600-SA PM(Prefix)HX-050-R900-SA PM(Prefix)HX-100-R900-SA PM(Prefix)HX-150-R900-SA PM(Prefix)HX-200-R900-SA PM(Prefix)HX-300-R900-SA PM(Prefix)HX-400-R900-SA PM(Prefix)HX-500-R900-SA PM(Prefix)HX-600-R900-SA PM(Prefix)HX-900-R900-SA

450 500 550 600 700 800 900 1000 1300 750 800 850 900 1000 1100 1200 1300 1600 1050 1100 1150 1200 1300 1400 1500 1600 1900

B mm

850 900 950 1000 1100 1200 1300 1400 1700 1450 1500 1550 1600 1700 1800 1900 2000 2300 2050 2100 2150 2200 2300 2400 2500 2600 2900


Perforated & Solid Cable Tray - Fittings Vertical Bends 90˚ (VO, VI) Formed

Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180° return flange not available on 025 tray heights.

Splice plates not supplied with fittings. Order standard splice plates separately from page 8. One (1) pair required to connect to system.

90˚ Vertical Inside

90˚ Vertical Outside

90˚ VO

100

90˚ VI

A

R A

100 B

100 TH

R

TH

B

100 Solid Bottom (R) Flange Shown

Solid Bottom (C) Flange Shown

90˚ Formed Bend Radius R

Tray Width

mm

mm

Catalog No.

300

600

900

(*) Insert "VO" for Vert. Outside Bend "VI" for Vert. Inside Bend

50

PF(Prefix)(*)-050-90R300-SA

100

PF(Prefix)(*)-100-90R300-SA

150

PF(Prefix)(*)-150-90R300-SA

200

PF(Prefix)(*)-200-90R300-SA

300

PF(Prefix)(*)-300-90R300-SA

400

PF(Prefix)(*)-400-90R300-SA

500

PF(Prefix)(*)-500-90R300-SA

600

PF(Prefix)(*)-600-90R300-SA

900

PF(Prefix)(*)-900-90R300-SA

50

PF(Prefix)(*)-050-90R600-SA

100

PF(Prefix)(*)-100-90R600-SA

150

PF(Prefix)(*)-150-90R600-SA

200

PF(Prefix)(*)-200-90R600-SA

300

PF(Prefix)(*)-300-90R600-SA

400

PF(Prefix)(*)-400-90R600-SA

500

PF(Prefix)(*)-500-90R600-SA

600

PF(Prefix)(*)-600-90R600-SA

900

PF(Prefix)(*)-900-90R600-SA

50

PF(Prefix)(*)-050-90R900-SA

100

PF(Prefix)(*)-100-90R900-SA

150

PF(Prefix)(*)-150-90R900-SA

200

PF(Prefix)(*)-200-90R900-SA

300

PF(Prefix)(*)-300-90R900-SA

400

PF(Prefix)(*)-400-90R900-SA

500

PF(Prefix)(*)-500-90R900-SA

600

PF(Prefix)(*)-600-90R900-SA

900

PF(Prefix)(*)-900-90R900-SA

VO Tray Height (TH) 25mm A B

50mm A B

75mm A B

VI Tray Height (TH) 100mm A B

25mm A B

50mm A B

75mm A B

100mm A B

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

425

425

450 450

475

475

500

500

425

425

450

450

475

475

500

500

N/A

N/A

N/A

N/A

725

725

725

725

750

750

775

775

800

800

N/A

N/A

N/A

N/A

750 750

775

775

800

800

1025 1025 1050 1050 1075 1075 1100 1100 1025 1025 1050 1050 1075 1075 1100 1100

N/A

N/A

N/A

N/A


Perforated & Solid Cable Tray - Fittings Vertical Bends 60˚ (VO, VI) Formed Splice plates not supplied with fittings. Order standard splice plates separately from page 8. One (1) pair required to connect to system.

60˚ Vertical Inside

60˚ Vertical Outside

100

60˚ VO

60˚ VI A

R

A

B 100

R

TH

100

TH

B

100 Solid Bottom (C) Flange Shown

Solid Bottom (R) Flange Shown

60˚ Formed *** Bend Radius R

Tray Width

mm

mm

Catalog No.

300

600

900

(*) Insert "VO" for Vert. Outside Bend "VI" for Vert. Inside Bend

50

PF(Prefix)(*)-050-60R300-SA

100

PF(Prefix)(*)-100-60R300-SA

150

PF(Prefix)(*)-150-60R300-SA

200

PF(Prefix)(*)-200-60R300-SA

300

PF(Prefix)(*)-300-60R300-SA

400

PF(Prefix)(*)-400-60R300-SA

500

PF(Prefix)(*)-500-60R300-SA

600

PF(Prefix)(*)-600-60R300-SA

900

PF(Prefix)(*)-900-60R300-SA

50

PF(Prefix)(*)-050-60R600-SA

100

PF(Prefix)(*)-100-60R600-SA

150

PF(Prefix)(*)-150-60R600-SA

200

PF(Prefix)(*)-200-60R600-SA

300

PF(Prefix)(*)-300-60R600-SA

400

PF(Prefix)(*)-400-60R600-SA

500

PF(Prefix)(*)-500-60R600-SA

600

PF(Prefix)(*)-600-60R600-SA

900

PF(Prefix)(*)-900-60R600-SA

50

PF(Prefix)(*)-050-60R900-SA

100

PF(Prefix)(*)-100-60R900-SA

150

PF(Prefix)(*)-150-60R900-SA

200

PF(Prefix)(*)-200-60R900-SA

300

PF(Prefix)(*)-300-60R900-SA

400

PF(Prefix)(*)-400-60R900-SA

500

PF(Prefix)(*)-500-60R900-SA

600

PF(Prefix)(*)-600-60R900-SA

900

PF(Prefix)(*)-900-60R900-SA

VO Tray Height (TH) 25mm A B

50mm A B

75mm A B

VI Tray Height (TH) 100mm A B

25mm A B

50mm A B

75mm A B

100mm A B

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

431

261

453 287

475

312

496

337

431

262

453

287

475

312

496

337

N/A

N/A

N/A

N/A

691

411

691

412

713

437

735

462

756

487

N/A

N/A

N/A

N/A

951

561

951

562

973

587

994

612 1016 637

N/A

N/A

N/A

N/A

713 437

973 587

735

994

462

756

487

612 1016 637


Perforated & Solid Cable Tray - Fittings Vertical Bends 45˚ (VO, VI) Formed

Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180° return flange not available on 025 tray heights.

Splice plates not supplied with fittings. Order standard splice plates separately from page 8. One (1) pair required to connect to system.

45˚ Vertical Inside

45˚ Vertical Outside

100

45˚ VO

45˚ VI A

R A B

100

R

100

TH

TH B

100 Solid Bottom (R) Flange Shown

Solid Bottom (C) Flange Shown

45˚ Formed *** Bend Radius R

Tray Width

mm

mm

Catalog No.

300

600

900

(*) Insert "VO" for Vert. Outside Bend "VI" for Vert. Inside Bend

50

PF(Prefix)(*)-050-45R300-SA

100

PF(Prefix)(*)-100-45R300-SA

150

PF(Prefix)(*)-150-45R300-SA

200

PF(Prefix)(*)-200-45R300-SA

300

PF(Prefix)(*)-300-45R300-SA

400

PF(Prefix)(*)-400-45R300-SA

500

PF(Prefix)(*)-500-45R300-SA

600

PF(Prefix)(*)-600-45R300-SA

900

PF(Prefix)(*)-900-45R300-SA

50

PF(Prefix)(*)-050-45R600-SA

100

PF(Prefix)(*)-100-45R600-SA

150

PF(Prefix)(*)-150-45R600-SA

200

PF(Prefix)(*)-200-45R600-SA

300

PF(Prefix)(*)-300-45R600-SA

400

PF(Prefix)(*)-400-45R600-SA

500

PF(Prefix)(*)-500-45R600-SA

600

PF(Prefix)(*)-600-45R600-SA

900

PF(Prefix)(*)-900-45R600-SA

50

PF(Prefix)(*)-050-45R900-SA

100

PF(Prefix)(*)-100-45R900-SA

150

PF(Prefix)(*)-150-45R900-SA

200

PF(Prefix)(*)-200-45R900-SA

300

PF(Prefix)(*)-300-45R900-SA

400

PF(Prefix)(*)-400-45R900-SA

500

PF(Prefix)(*)-500-45R900-SA

600

PF(Prefix)(*)-600-45R900-SA

900

PF(Prefix)(*)-900-45R900-SA

VO Tray Height (TH) 25mm A B

50mm A B

75mm A B

VI Tray Height (TH) 100mm A B

25mm A B

50mm A B

75mm A B

100mm A B

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

401

184

418 209

436

234

454

259

401

184

418

209

436

234

454

259

N/A

N/A

N/A

N/A

613

271

613

271

630

296

648

321

666

346

N/A

N/A

N/A

N/A

825

359

825

359

842

384

860

409

878

434

N/A

N/A

N/A

N/A

630 296

842 384

648

860

321

409

666

878

346

434


Perforated & Solid Cable Tray - Fittings Vertical Bends 30˚ (VO, VI) Formed Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180° return flange not available on 025 tray heights.

Splice plates not supplied with fittings. Order standard splice plates separately from page 8. One (1) pair required to connect to system.

30˚ Vertical Inside

30˚ Vertical Outside

30˚ VO

100

30˚ VI A

R

A

B

100

R 100

TH

TH

100

B Solid Bottom (C) Flange Shown

Solid Bottom (R) Flange Shown

30˚ Formed Bend Radius R

Tray Width

mm

mm

Catalog No.

300

600

900

(*) Insert "VO" for Vert. Outside Bend "VI" for Vert. Inside Bend

50

PF(Prefix)(*)-050-30R300-SA

100

PF(Prefix)(*)-100-30R300-SA

150

PF(Prefix)(*)-150-30R300-SA

200

PF(Prefix)(*)-200-30R300-SA

300

PF(Prefix)(*)-300-30R300-SA

400

PF(Prefix)(*)-400-30R300-SA

500

PF(Prefix)(*)-500-30R300-SA

600

PF(Prefix)(*)-600-30R300-SA

900

PF(Prefix)(*)-900-30R300-SA

50

PF(Prefix)(*)-050-30R600-SA

100

PF(Prefix)(*)-100-30R600-SA

150

PF(Prefix)(*)-150-30R600-SA

200

PF(Prefix)(*)-200-30R600-SA

300

PF(Prefix)(*)-300-30R600-SA

400

PF(Prefix)(*)-400-30R600-SA

500

PF(Prefix)(*)-500-30R600-SA

600

PF(Prefix)(*)-600-30R600-SA

900

PF(Prefix)(*)-900-30R600-SA

50

PF(Prefix)(*)-050-30R900-SA

100

PF(Prefix)(*)-100-30R900-SA

150

PF(Prefix)(*)-150-30R900-SA

200

PF(Prefix)(*)-200-30R900-SA

300

PF(Prefix)(*)-300-30R900-SA

400

PF(Prefix)(*)-400-30R900-SA

500

PF(Prefix)(*)-500-30R900-SA

600

PF(Prefix)(*)-600-30R900-SA

900

PF(Prefix)(*)-900-30R900-SA

VO Tray Height (TH) 25mm A B

50mm A B

75mm A B

VI Tray Height (TH) 100mm A B

25mm A B

50mm A B

75mm A B

100mm A B

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

349

115

362 140

374

165

387

190

349

115

362

140

374

165

387

190

N/A

N/A

N/A

N/A

499

155

499

155

512

180

524

205

537

230

N/A

N/A

N/A

N/A

649

196

649

196

662

221

674

246

687

271

N/A

N/A

N/A

N/A

512 180

662

221

524

674

205

246

537

687

230

271


Perforated & Solid Cable Tray - Straight Section Covers Straight Section Covers

Solid Flanged

Cover Tray Width + 4mm Thickness 15

A full range of covers is available for straight sections. Solid flanged covers should be used when maximum enclosure of the cable is desired and no accumulation of heat is expected. Flanged covers have a 15mm flange. Cover clamps are not included with the cover and must be ordered separately.

Straight Section Cover Part Numbering Example: PC F S P 15 SS - 300 - 3000 - SA

Cover Type

Cover Style

Top Style

PC =

F= Formed

S= Solid

(Perforated & Solid Tray Cover)

(Southern Asia)

Material

Thickness

Type

Width

Length **

P = Pre-Galv G = HDGAF SS6 = Stainless Type 316

10 * = 1.0mm 15 = 1.5mm

SS = Straight Section

050 = 50mm 100 = 100mm 150 = 150mm 200 = 200mm 300 = 300mm 400 = 400mm 500 = 500mm 600 = 600mm 900 = 900mm

1500 = 1.5m 3000 = 3.0m


Perforated & Solid Cable Tray - Fitting Covers Fitting Covers HT Horizontal Tee

HT Horizontal Bend

Mitered Shown

Mitered Shown

HX Horizontal Cross Formed Shown

VO Vertical Outside Bend

VI Vertical Inside Bend

Formed Only

Formed Only

LR Right Reducer

SR Straight Reducer

RR Left Reducer

Mitered Only

Mitered Only

Mitered Only

A full range of covers are available for fittings. Solid flanged covers should be used when maximum enclosure of the cable is desired and no accumulation of heat is expected. Flanged covers have a 15mm flange. Cover clamps are not included with the cover and must be ordered separately.

Fitting Cover Part Numbering Example: PC F S P 15 HB - 500 - 60 R600 - 050 - SA

Cover Type

Cover Style

Top Style

PC =

F= Formed M= Mitered

S= Solid

(Perforated & Solid Tray Fitting Cover)

(Southern Asia)

Angle † Material

Thickness

P = Pre-Galv G = HDGAF SS6 = Stainless Type 316

10 * = 1.0mm 15 = 1.5mm

Type

HB HT † HX † VO *** VI *** RR † LR † SR †

Width

(°)

Radius

Tray Height †††

050 = 50mm 100 = 100mm 150 = 150mm 200 = 200mm 300 = 300mm 400 = 400mm 500 = 500mm 600 = 600mm 900 = 900mm

30 45 60 90

R300 = 300mm R600 = 600mm

025 = 25mm 050 = 50mm

R900 = 900mm

075 = 75mm 100 = 100mm


Stainless Steel Consoles 1. 2. 3. 4.

5. 6. 7. 8.

Console with sloping top and sloping upper lid Hidden hinges & gas strut Double depth adjustable mounting plate Gland plate & eyebolts on the top Material: Unpainted brushed stainless steel AISI 304 & 316 Ingress Protection: IP54 Colour: Natural Sizes: 15 sizes available from 600mm to 2000mm width

Double Wall Mounting Aluminum Enclosures 1. Double Wall construction is fully ventilated 2. Free _ow air tubes are placed between the outer and inner walls and thus the interior temperature is remarkably lower than in the Single Wall Enclosure 3. Ventilated doors, walls & detachable Canopy 4. Plinth is in-built or available separately 5. Ingress Protection: IP55 6. Finish: Polyester powder coating RAL7032 7. Sizes: 15 sizes from 1000H x 600W x 300D (mm) to 2000H x 1400W x 600D (mm)

Wall Mounting Stainless Steel Enclosures 1. Stainless steel AISI 316 enclosures with 1 or 2. 2 door latches depending on size No gland plate openings with galvanised steel or Stainless steel mounting plate 3. Ingress Protection: IP54 4. Finish: Unpainted brushed stainless steel 5. Colour: Natural 6. Sizes: 31 sizes from 200x300x150mm to 1200x1000x300mm


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.