CAPITAL MARKET AUTHORIT Y TOWER S I G N A G E S Y S T E M A N D G R A P H I C D I S P L AY S R I YA D H | K I N G D O M O F S A U D I A R A B I A

SIGNAGE AND WAYFINDING STANDARDS Prepared by HOK Visual Communications


2 CMA Tower Riyadh, Kingdom of Saudi Arabia

Signage System and Graphic Displays Signage and Wayfinidng Standards

Table of Contents

Sign Family Presented as Overarching Solution Acknowledgement The HOK Visual Communications design team would like to thank our colleagues inside HOK Advance Strategies, Architecture, & Interiors for their help in contributing to this effort. We also thank our consultants at Xibitz and JSAV for their insights on fabrication and electronic media.

3

Overview 1.1 Materials 1.2 Directional Arrows 1.3 Patterns

Translations

1.4 Typography

In this document we have used for all Arabic translations. This was done specifically to avoid errors in translation. It is of course offered as a placeholder only and final translations will be completed by a professional language translator chosen by owner.

1.5 Icons and Pictographs 1.6 Mapping Graphics 1.7 Tale of Two Brands 1.8 Typical Installations

Naming The destination names used in this sign package are placeholders for illustration purposes only.

22

Interior Signage 2.1 Freestanding Interior Signs 2.2 Overhead Interior Signs

Colors

2.3 Wall Mounted Interior Signs

The color rendition of the signs within this book will vary depending on quality and calibration of both the monitor the digital files will be viewed on and the printer used to acquire hard copies. Use the Pantone Matching System as a guide to achieve the desired colors. True references should be made by obtaining actual sample materials from the manufacturer.

2.4 Vinyl Graphics and Fabricated Letterforms 2.5 Architectural Notions and Graphic Displays 168

Exterior Signage 3.1 North Announcer 3.2 South Announcer 3.3 Plaza Announcer

228

Specifications


Materials, Patterns, Graphic Film, and Other Details Descriptions and Processes


4 CMA Tower Riyadh, Kingdom of Saudi Arabia

Materials Descriptions of Materials for Use in All Sign Types

Materials Identification Overview of construction materials for all sign types including code-required (ANSI / NFPA / IBC) regulatory signs, ceiling mounted signs, wall mounted signs, and freestanding signs.

SS

AL

VL

MA

SC

LL

For its high aesthetic qualities, excellent durability against impact, and anti-corrosive properties. Steel to be stainless marine grade type 316 with satin, medium horizontal brush finish.

Chosen for its close resemblance to stainless steel and for its wide variety of gauges, sheet sizes, and finishes.

Non-glare, matte finish, high quality ,self-adhesive, die-cut vinyl material. All vinyl is cut with smooth edges.

Thin, high holding power, nickel plated, magnetic block, high resistance to demagnetization.

Commercial quality "aircraft grade" cable is made from galvanized steel wire. Galvanized aircraft cable provides high tensile strength and adequate corrosion resistance for most applications.

Philips eW Graze Powercore, outdoor rated, evenly lit, high performance illumination and beam quality LED lights. Linear lighting fixture optimized for surface grazing and wall-washing applications requiring high quality white.

Stainless Steel

Aluminum

Aluminum should replace stainless steel in the event that weight proves to be an issue for ceiling suspended signs.

Vinyl

Magnetic Block

Suspension Cable

Consult structural engineer for exact specifications.

LED Lighting


5 CMA Tower Riyadh, Kingdom of Saudi Arabia

Materials Descriptions of Materials for Use in All Sign Types

Materials Identification Overview of construction materials for all sign types including code-required (ANSI / NFPA / IBC) regulatory signs, ceiling mounted signs, wall mounted signs, and freestanding signs.

CA

GL

CV

CT

TA

Strong, light weight (half as much as glass), and resists aging under a wide range of temperatures. Transparent as the finest optical glass while providing excellent light transmission.

Non-glare coated and optically clear without color cast of color when viewed at any angle.

Non-glare, smooth finish, exterior grade ecoresin. Strong, light weight, allowing for easy fabrication and maximum installed durability. UV-rated against yellowing in exterior environments.

Strong and durable, can bear rapid temperature change. Glass to be chemically colored matching PMS 2607C (purple) and PMS 2945C (blue).

Basic attributes identical to clear acrylic. The color specifications of tinted acrylic are the same throughout the document (RCast, gray matching PMS Cool Gray 11C) unless noted otherwise. Tinted acrylic is to be used primarily as the material for legend text as noted. Acrylic material to endure fine cutting, sanding, polishing, and other methods of finishing without defects.

Clear Acrylic

Diamond polish all exposed edges for smooth and glossy finish.

Optically Clear Glass

All edges exposed or unexposed to viewing must be blemish-free and polished.

Clear Varia Ecoresin XT

All edges must be blemishfree and polished.

Color-Treated Glass

All edges exposed or unexposed to viewing must be blemish-free and polished.

Tinted Acrylic

LT

Laminated Tempered Glass Low iron starphire laminated tempered glass with ultra clear interlayers. Low iron content decreases the green tint characteristic of standard clear glass. This allows more light to pass through the glass. All edges exposed or unexposed to viewing must be blemish-free and polished.


6 CMA Tower Riyadh, Kingdom of Saudi Arabia

Materials Descriptions of Materials for Use in All Sign Types

Materials Identification Overview of construction materials for all sign types including code-required (ANSI / NFPA / IBC) regulatory signs, ceiling mounted signs, wall mounted signs, and freestanding signs.

DF

GF

DA

CF

EG

DO

White translucent acrylic panel, light weight, non-yellowing, excellent light diffusion without losing light efficiency. Distributes light evenly across entire surface and creates softer, unfocused light.

Optically clear graphic film, smooth suface captures digital four-color output, allows transparent and translucent images. Clear self-adhesive back.

Indication of a direction in a sign’s message is presented by a dimensional acrylic arrow. The arrow is a solid piece of clear acrylic with corners and edges beveled and rounded. Diamond polish the surfaces for a smooth, glossy finish. The source of color and graphic is the digital output underneath which is attached to the arrow using clear adhesives.

The iridescent, translucent, and vibrant qualities of the crystalline graphics are achieved through the layering of several different materials—each with its unique visual quality—and laminated as a single film. The laminated film is always placed behind a clear acrylic block or panel for protection.

Line and legend to be etched just adequate to be visible.

For Backlit Displays only (Light Box): Kodak Professional Duratrans Display Material for brilliant display transparencies from color negatives or internegatives. For Other Non-Backlit Inserts: Paper or other quality printable substrates are acceptable. Smooth, non-glossy finish. Art output recommended at the highest possible quality settings to be used (200 dpi minimum at actual size) for legibility of small type. Full color (CMYK minimum) process.

Diffuser

Graphic Film

Directional Arrow

Crystalline Graphic Film

Note: In applications where the film is backlit and necessary for light transmission, use WITHOUT opaque white backing.

Etched Graphic

Faceted pattern to be etched at least 1mm in depth and filled with gray matching PMS Cool Gray 11C. It is created by diagonal and intersecting angular lines forming faceted, polygonal geometry. (See sections of Faceted Crystalline Pattern and Etched Type and Graphics for details)

Digital Output


7 CMA Tower Riyadh, Kingdom of Saudi Arabia

Directional Arrow Usage and Details

Clear acrylic with diamond polished surface and edges

Forward

90°

(Align to center of arrow)

Digital output with three color fields (to further simulate dimensionality of arrow) and fit the flat surface at the underside arrow. Color side facing and visble to viewer.

45°

Forward and/or Level Change Up

135°

For output, use file directional_arrow_art.ai

DA

Directional Arrow Indication of a direction in a sign’s message is presented by a dimensional acrylic arrow. The arrow is a solid piece of clear acrylic with corners and edges beveled and rounded. Diamond polish the surfaces for a smooth, glossy finish. The source of color and graphic is the digital output underneath which is attached to the arrow using clear adhesives.

1

Dimensional View

7

NTS

180°

0° Left

Clear acrylic

Right

315°

225°

Layer of clear adhesive

Level Change Down

Digital output

Layer of clear adhesive (adhere to structure)

2

Dimensional View

3

Orientations of Arrow

7

NTS

7

Scale 1:4

Level Change Down


8 CMA Tower Riyadh, Kingdom of Saudi Arabia

Directional Arrow Measurements 55 6

40

8

All corners are beveled and rounded. Create a rounded ridge, 1mm width, along the edges of the acrylic arrow.

1

55

120° 25°

35°

1

Plan View

6

Detail View

8

Scale 1:1

8

Scale 3:1

1

Detail of rounded ridge

1

1

16

60° 30°

2

Top View

4

Plan View

7

Detail View

8

Scale 1:1

8

Scale 2:1

8

Scale 3:1

Top View

8

Detail View

Scale 2:1

8

Scale 3:1

55

7 7

1 8 8

16

115° 45°

3

Right Side View

8

Scale 1:1

20°

5 8


9 CMA Tower Riyadh, Kingdom of Saudi Arabia

Crystalline Graphic Film Film Selection, Layering, and Lamination

Usage For sign type in which the use of Crystalline Graphic Film is specifically noted. This film is to be used with clear acrylic (flat panel or shaped) at all times for rigidity and protection.

Film Composition and Other Components The three components of the film are highlighted in the blue and white boxes.

Opaque White Backing (for non-backlit application ONLY)

SOLYX Clear Icicles SOLYX Bahama HDTE Film (digitally printed)

CF

Crystalline Graphic Film The iridescent, translucent, and vibrant qualities of the crystalline graphics are achieved through the layering of several different materials—each with its unique visual quality—and laminated as a single film. The laminated film is always placed behind a clear acrylic block or panel for protection. Note: In applications where the film is backlit and necessary for light transmission, use WITHOUT opaque white backing.

Acrylic Block or Panel (reference Clear Acrylic) Viewing Direction

Viewing Direction

This film is created by lamination of the three films listed below without deviation from this order, from front to rear—HDTE Film (printed with graphic), SOLYX Bahama Film, and SOLYX Clear Icicles Film. Remove air bubbles or air gaps on the surface, front or back. Carefully squeegee out air gaps on the entire surface of the film to ensure a smooth surface prior to mounting. Lamination substrate and adhesives must be invisible to view and not interfere with transmission of light. Choice of lamination substrate must seal the enclosed films from moisture and dust. HDTE Clear Film This method of printing involves dye-sublimation by printing images on the substrate and then encapsulated with a top layer protecting the image below. The output must have adequate coverage and rich saturation for all subsequent films to take on the colors of this graphic as their primary color tonality.

SOLYX Bahama Film Iridescent Dichroic Polyester film. The color tonality of this film changes when viewed at different angles, but will stay mostly within the blue and purple tones. No dyes or metals are used in the construction of this film, making it possible for backlit applications. Scratch resistant coating on surface.

SOLYX Clear Icicles Film Translucent embossed vinyl film. Light scattering prisms make this film look like frosted-cut glass while giving the illusion of dimensional facets on the flat printed film. The tactile side of the film must be turned away from viewing direction in the lamination process to minimize air bubbles from appearing.

For more information on both SOLYX films: http://www.decorativefilm.com/index.asp


10 CMA Tower Riyadh, Kingdom of Saudi Arabia

Faceted Crystalline Pattern Side and Periphery Graphic Detail

Description A standard pattern is developed to appear on most freestanding and ceiling mounted sign types within the tower. This crystalline pattern takes form from a similar pattern that appears in spaces within the tower on the walls of the elevator bay and reception lobby. It is created by diagonal and intersecting angular lines forming faceted, polygonal geometry.

Usage and Cutting Details The usage of a standard pattern is compatible to use where the structural material is metal, often at the sides and other peripheral areas where a metal surface is present. The form of the pattern lends itself to expanding and contracting to accommodate various areas on signs yet retains a seamless appearance.

EG

Etched Graphic Line and legend to be etched just adequate to be visible. Faceted pattern to be etched at least 1mm in depth and filled with gray matching PMS Cool Gray 11C. Created by diagonal and intersecting angular lines forming faceted, polygonal geometry.

Pattern on the metal panel is to be processed as a continuous piece then cut into smaller pieces for visual continuity. The resulting pattern should be easily visible from a distance of <2m away. NOTE: Each sign type where this pattern appears is assigned with its own art file for fabrication. The name of the file will be indicated in the Materials & Finishes section of each sign.

Size adjustment is permissible only if the stroke weight of the etched lines are kept constant at 3mm wide across all sign types. Lines must appear depressed at a distance which means the lines must be cut with adequate depth. For this detail we recommend a depth of 1.5mm deep, or, the maxiumum depth the etching machinery allows but no less than 1mm in depth. Each line cut is to be filled with gray matching PMS Cool Gray 11C in matte finish. Bevel and sand away uneven edges prior to application of paint. Lines are to appear continuous and straight without breaks at intersections (see illustrations).

3mm stroke width 1.5mm depth Line cut Paint fill Metal panel


11 CMA Tower Riyadh, Kingdom of Saudi Arabia

Typography Visually Bilingual

The GE Dinar One font family has been chosen for all signage in Arabic. For most legends use GE Dinar One Medium.

The Gil Alt One MT font family has been chosen for all signage in English. For legends use Gil Alt One MT Light.

Occasionally, when a slightly lighter weight may be needed, use GE Dinar One Light, but avoid using for entire legend.

Occasionally, when a slightly heavier weight may be needed, use Gil Alt One MT Regular, but avoid using for entire

Use automatic leading for appropriate spacing between Arabic legends.

legend. In general, be more generous with leading than the default setting of most design applications.

Where To Find It

Where To Find It

Version of GE Dinar One Light can be found at http://www.boutrosfonts.com.

Version of Gil Alt One MT can be found at http://www.fonts.com.

Primary Typefaces - Arabic

Primary Typefaces - Latin

ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz 0123456789 GE Dinar One Light

Gil Alt One MT Light

ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz 0123456789 GE Dinar One Medium

Code regulated signage is required to use GE Dinar One Medium and Gil Alt One MT Regular

Gil Alt One MT Regular


12 CMA Tower Riyadh, Kingdom of Saudi Arabia

Typography Typographic Details for Freestanding Signs

A

B

435

45

TYPOGRAPHIC DETAILS All measurements are recorded in millimeters.

215 C

A Dividing Rule

F Arabic Legend Leading

Dividing rule is 2mm in thickness. No part of the message, both graphical or typographical, should extend beyond the dividing rule.

Use automatic leading specific to the Arabic font size for appropriate spacing. G English Legend Leading

Reception Desk

25

D

25

E

Auto F

Main Lobby Main Lobby

Auto G 55

H

45

I

20

J

13

K

35

L

B Right Margin

Use automatic leading specific to the English font size for appropriate spacing.

C Top Margin H Spacing Between Arrow and English Legend D Arabic Legend Typeface: GE Dinar One Light Auto kerning. Font size is to be determined by the measurement of alif-height as indicated in document. Alif-height can be obtained by measuring the distance between baseline to the top of ascender. See example. Top of Ascender

Alif-Height

Parking Transportation

Baseline

E English Legend Typeface: Gil Alt One MT Light Optical kerning. Font size is to be determined by the measurement of cap-height as indicated in document. Cap-height can be obtained by measuring the distance between baseline to the top of ascender. Title Case for all English messages. See example.

Elevators

Top of Ascender

Parking Transportation

1

Freestanding Typographic Detail

13

Scale 1:15

Cap-Height

Baseline

Measurement from baseline of English legend to a directional arrow. I Spacing Between Arrow and Arabic Message Measurement from arrow to top of the ascender of Arabic message. J Spacing Between Arabic Message and Dividing Rule Measurement from baseline of the Arabic message above to divider rule below. K Spacing Between Dividing Rule and English Message Measurement from divider rule to the top of the ascender of English message below. L Spacing Between English Legend and Arabic Legend Measurement from baseline of the English message to the top of ascender of Arabic message.


13 CMA Tower Riyadh, Kingdom of Saudi Arabia

Typography Typographic Details for Wall Mounted Signs

TYPOGRAPHIC DETAILS A

B

C

26

390

26

All measurements are recorded in millimeters. A Left Margin

84

Level 35 Information

D

19 12 10 25 17

E F G H I

19

J

23

K

22

L

I English Header Bottom Margin

B Dividing Rule

J Arabic Message

Dividing rule is 2mm in thickness for the header and 1mm for all others. No part of the message, both graphical or typographical, should extend beyond the dividing rule.

Typeface: GE Dinar One Light Auto kerning.

C Right Margin

Typeface: Gil Alt One MT Light Optical kerning.

D Top Margin

K English Message

L Arabic Message Top Margin

E Arabic Header Typeface: GE Dinar One Light Auto kerning. Font size is to be determined by the measurement of alif-height as indicated in document. Alif-height can be obtained by measuring the distance between baseline to the top of ascender. See example. Top of Ascender

Alif-Height

M English Message Bottom Margin N Spacing Between Arabic Message and Dividing Rule Measurement from baseline of the Arabic message above to divider rule below. O Spacing Between Dividing Rule and English Message Measurement from divider rule to the top of the ascender of English message below. P Spacing Between Arrows and Legends

Information

Baseline

22 12 8

Information

M

N O

F Spacing Between Arabic Header and Dividing Rule Measurement from baseline of the Arabic header above to divider rule below. G Spacing Between Dividing Rule and English Header Measurement from divider rule to the top of the ascender of English header below. H English Header

Information 23

23

P

P

Information

1

Wall Mounted Typographic Detail

14

Scale 1:5

Typeface: Gil Alt One MT Light Optical kerning. Font size is to be determined by the measurement of cap-height as indicated in document. Cap-height can be obtained by measuring the distance between baseline to the top of ascender. Title Case for all English messages. See example. Top of Ascender Cap-Height

Baseline

Left Arrows: Measure from the right-most part of the arrow to the left side of dividing rule. Right Arrows: Measure from the left-most part of the arrow to the right side of dividing rule.


14 CMA Tower Riyadh, Kingdom of Saudi Arabia

Icons and Pictographs For Common Uses

Egress / Safety Elevator

Service Elevator

Stair Down

Stair Up

Exit

Fire Exit

Escalator Up

Escalator Down

Fire Extinguisher

Surveillance Camera

Security

Clinic / First Aid

Amenities Cafeteria

Dining

Postal

Mushollah

Shopping

Water Fountain

Litter Disposal

Telephone

Locker Room

Parking

Prohibitory No Smoking

No Phone

No Weapons

No Exit

Restrooms Men

Women

Restroom

Accessibility

Do Not Enter

No Eating or Drinking

Attention

No Camera

Information


15 CMA Tower Riyadh, Kingdom of Saudi Arabia

Mapping Graphics Artistic Direction

Map Details and Layout All details (map art, icons, route, header....etc) found on an evacuation map are systematically arranged within a conventionally availble paper size for in-house color laser printing. However, it is recommended that the maps to be printed by a professional digital printer for high quality results. The left portion of the layout is reserved for the map art and the right portion reserved for all other typographic / graphical information.

LEVEL

This portion reserved for map art

This portion reserved for header and legend

30

Trim Line

Evacuation Plan Legend Key Elevator

Stair way

Exit Route

LEVEL

You Are Here

123- 4567 123- 4567

DO

Digital Output For Backlit Displays only (Light Box): Kodak Professional Duratrans Display Material for brilliant display transparencies from color negatives or internegatives. For Other Non-Backlit Inserts: Paper or other quality printable substrates are acceptable. Smooth, non-glossy finish. Art output recommended at the highest possible quality settings to be used (200 dpi minimum at actual size) for legibility of small type. Full color (CMYK minimum) process.

Right margin (with bleeds)

30

Level Number

Tower Security

Arabic Header

Fire Depar tment

Option for Four Color Silkscreen Printing The number of colors on the map art is reduced

Evacuation Plan

English Header

to four, thus allowing art to be screen printed directly on a variety of materials, such as glass

Legend Key

and metals. Elevator

Stair way

Exit Route

Bilingual Legend and Graphic Icons Arabic legend on top, English legend at the bottom

You Are Here

123- 4567

Tower Security

123- 4567

Fire Depar tment

Area for Additional Information For useful contact numbers or other useful instructions


16 CMA Tower Riyadh, Kingdom of Saudi Arabia

Mapping Graphics Artistic Direction

LEVEL 1

Non-Level Specific Amenities Bilingual key with Arabic column to the right and English to the left of the central column of icons. Icons are coded in contrasting colors, accompanied with graphics/symbols.

Floor Identification Header Color field behind bilingual floor level information; CMA Tower colors.

Map Art Floor map presented in isometric format. Isometric formula of art adjusted to enhance the viewer’s visibility of details to aid wayfinding. Tower structure / non-destinations illustrated in neutral shades of grey in contrast with the vibrant color scheme of icons and locations.

th ontrrance

NE

Level Specific Location Key Each location is designated with an assigned number within a green box that corresponds with the location of the amenity as it appears on the map. Three column arrangement with Arabic to the right, icons at center, and English to the left.

Men’s Restroom Escalator

1

Auditorium

Information

2

Green Room

Elevator to CMA Levels

3

VIP Lounge

Elevator to Local Levels

4

Location Name

Elevator to Mid-Rise Levels

5

Location Name

6

Location Name

7

Location Name

Levels Number 00-00

Levels Number 00-00

Levels Number 00-00 2

To p

h utnce SoEntra

You Are Here

Fr

1 3

on

t

Elevator to Parking S

id

X

e

Podium Levels Elevator X

Information Elevator to CMA Levels Levels Number 00-00

Elevator to Local Levels Levels Number 00-00

Elevator to Mid-Rise Levels Levels Number 00-00

Elevator to Parking

Extension of List

Security Check

Men’s Restroom Escalator

Extra Line Arrangement for Long Legends

Amenities Icons Non-level specific. For locations that appear on multiple levels, such as restrooms and elevators.

Podium Levels Elevator

Other Graphical Elements Additional elements, such as symbols, illustrations, and textures, are used to enhance the legibility and visual quality of the map.

Security Check

1

Legend Here

4

Legend Here

7

Legend Here

2

Legend Here

5

Legend Here

8

Legend Here

3

Legend Here

6

Legend Here

9

Legend Here

Quick Reference Security Desk

123-4567

Tower Information

123-4567

Telephone Directory

123-4567

Location Key For locations that are level specific. Quick Reference Special messages or phone numbers to tower management, etc.

You Are Here Escalator Icon paired with destination

Compass

You Are Here

Map Texture

Graphic of Exterior Features


17 CMA Tower Riyadh, Kingdom of Saudi Arabia

Tale of Two Brands Capital Market Authority Branding vs. CMA Tower Branding

Capital Market Authority Signage (For use on CMA specific floors only)

CMA Tower Signage (For use in general/public floors )

The signage for Capital Market Authority is specifically referencing the established look and feel of the corporate brand. The color reveal reflects the proximate tonality of the brand’s blue colors (PMS 2945 and PMS 2905). The diamond shape in the Capital Market Authority logo is subtly reflected in the faceted cuts and angular lines found on the signage.

The colors and form of the CMA Tower signage is complementary to the signage found on the Capital Market Authority floors yet distinctive enough to differentiate between the two brands. The basis of the tower signage emphasizes the architectural aesthetics of the tower — faceted cuts and color reveal appearing at the top edge symbolizes the “crown” at the top of the tower. The use of colors (Royal purple with a hint of blue/ sapphire colors) and typography serve as the visual connection between the brands.

NOTE: Printer must calibrate output process to achieve closest color match.

Directory

Directory

Large Conference Room

Large Conference Room

MEN

Information

Information

Information

Information

Information

Information

Information

Information

Information

Information

MEN


18 CMA Tower Riyadh, Kingdom of Saudi Arabia

Typical Installation Wall Mounting General Notes

A. Assemble, unless otherwise specified, with appropriate adhesive. No adhesive is to be visible. B. Mount assembled sign unit to wall surface with double-faced foam tape and clear silicone glue. Thickness of foam tape shall be thickness needed to achieve maximum adhesion. No adhesive is to be visible. Existing wall

1 Installing on Gypsum Wallboard (2 options)

Existing wall

Existing wood panel Double-faced foam tape

Double-faced foam tape

Double-faced foam tape

Double-faced foam tape

Double-faced foam tape

Pin (add pin in addition to tape for large signs for increased adherence)

Plastic toggle PLA screws

3mm backplate

3mm backplate

Double-faced foam tape

B. Use wall fasteners, double-faced foam tape to mount on wall. Clear acrylic backing plate. 3mm backplate

Sign Sign

A. Use double-faced foam tape and silicone glue to mount on wall. Do not use this method if wall has covering as foam tape and silicone may not adhere. Clear acrylic backing plate.

Sign

Pin

1

Installing on Gypsum Wallboard (A)

2

Installing on Gypsum Wallboard (B)

3

Installing on Wood / Wood Veneer

FS

Scale 1:2

FS

Scale 1:2

FS

Scale 1:2

2 Installing on Wood or Plywood Paneling

Mount signs with double-faced foam tape only. Do not use silicone or wall fasteners.


Interior Signage Measurements, Descriptions, and Construction Details


20 CMA Tower Riyadh, Kingdom of Saudi Arabia

Freestanding Directional [FS] Measurements, Descriptions, and Construction Details Measurements in millimeters

Fabrication Notes & Requirements

450

135

110

1

25

Etched pattern

Etched pattern

English Legend Information

Crystalline Graphic See section on Crystalline Graphic Film. Backlit with internal LED illumination. 6000K white balance. Acrylic pieces are diamond polished and install without visible seams or gaps. No fasteners shall be visible from within acrylic.

Main Lobby

Information

2045

Information

1

26

2

55

Seams should be kept to a minimum and no open gaps of more than 1mm are acceptable. Structure should be symmetrical and structurally sound. Use additional structural reinforcement (internal and hidden from view) if deemed necessary from an engineering standpoint. Exposed edges are to be beveled and smoothed-out, leaving no sharp edges that can cause injuries. If components are manufactured separately, the overall finish and color of material must be visually identical after assembly. Secure sign structure to ground using expansion bolts. Production of a full-scale, working prototype is HIGHLY RECOMMENDED for this sign type to test for structural durability, functionality, and aesthetic quality.

65

25

Base skirt

65 40 174

180

1

Small Freestanding Directional

2

Left Side View

3

Right Side View

23

Scale 1:20

23

Scale 1:20

23

Scale 1:20


21 CMA Tower Riyadh, Kingdom of Saudi Arabia

Freestanding Directional [FS] Material Identification Material Identification Refer to Material Identification Section

A

A

A

C

A

B

Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish. Structure Side (Left and Right) Stainless steel marine grade type 316 with satin, medium horizontal brush finish.

MAT

SS

MAT

SS

MAT

VY

MAT

SS

MAT

MAT

MAT

EG

CA

MAT

DA

CA

MAT

CF

Faceted crystalline pattern to be etched and filled on stainless steel structure (see section of Faceted Crystalline Pattern). E C

E

F B

B

D Base Skirt Stainless steel marine grade type 316 with satin, medium horizontal brush finish.Transparent coating to protect from scuffs and scratches.

E

F

D

1

Isometric for Material Identification

24

Scale NTS

Legend Type Gray vinyl matching PMS Cool Gray 11C. Non-glare, matte finish, high quality, self-adhesive vinyl is to be cut with smooth edges.

Directional Arrow Dimensional acrylic arrow (see section of Directional Arrow for details). For digital output, use art file: directional_arrow_art.ai

D

F

Crystalline Facet Acrylic to be cut and formed to shape of facet. All films are laminated together and sandwiched between acrylic blocks (see section of Crystalline Graphic Film for details).


22 CMA Tower Riyadh, Kingdom of Saudi Arabia

Freestanding Directional [FS] Section View and Descriptions

B

I

D

Wrapping Panel Only 3mm thick stainless steel panel with etched pattern; wrap around forming edges and securing acrylic components in place.

B

Exterior Cabinet Formed from 3mm thick stainless steel for structural durability.

C

Bottom Acrylic Block Clear acrylic block cut to shape as specified; secured to the anchor base and exterior cabinet.

D

Support Frame Extends from top of sign to ground. Provides primary support for the entire signage structure.

E

Clear Acrylic 12mm thick.

F

Crystalline Graphic Film See Crystalline Graphic Film section for more information.

G

Diffuser Backer 6mm thick acrylic.

H

Open Space

I

LED Lights

J

Steel Pegs Pegs used for securing acrylic panels or block to the external cabinet body; correspond with drilled holes in acrylic / diffuser material.

K

Stainless Steel Panel 3mm thick with etched pattern.

L

Cross Bracket Beams attaching the exterior cabinet body to the internal support structure. Do not block path of light.

M

Z Clips Securing stainless steel panel to internal support structure. Removable for accessibility for servicing and maintaining LED components.

N

Base Skirt

N

30

A

A

C

M

110

180

H

H

30

C

15

E F G

1

Section View

26

Scale 1:3

G

F

C

L

J

I

L

K


23 CMA Tower Riyadh, Kingdom of Saudi Arabia

Freestanding Directional [FS] Isometric Section View G E F

J

I B

P A

Wrapping Panel 3mm thick stainless steel panel with etched pattern visble to viewer; wrap around forming protecting edges.

K

Side Panel 3mm thick stainless steel etched with faceted crystalline pattern.

B

External Cabinet Body 3mm thick stainless steel.

L

Anchor Base Stainless steel skirt concealing leveling nuts and anchoring bolts. Secure to ground.

C

Clear Acrylic Block Block is secured to the anchor base and the external cabinet body.

D

Support Frame Extends from top to bottom and attaches to anchor base; anchors securely into base as a crucial structural component.

E

Clear Acrylic 12mm thick.

F

Crystalline Graphic Film Pattern must look continuous at completion without obvious breaks in graphic. See Material section for more information on graphic film. Note: Print crystalline graphic on one continuous piece of graphic film then cut into shape and reassemble to ensure a continuous look. Repeat process for each individual sign.

N A D K B

K

M O

C

L

1

Isometric View

27

Scale NTS

G

Diffuser Backer 6mm thick clear acrylic.

H

Open Space

I

LED Lights Drawing for instructional purposes only; consult lighting technician/designer.

J

Steel Pegs Pegs used for securing acrylic to the external cabinet body.

M Chemical Weld Joint Transparent and seamless chemical fusion at the joint of acrylic pieces. N

Cross Bracket Folded stainless steel component welded to the second surface of the external cabinent body. Fasten the opposite end to the support frame.

O

Fastener Contersinking fastener for attaching side panel to the support frame; install flush to surface of panel. 10mm in diameter. Avoid positioning fasteners over etched lines.

P

Horizontal Beam

Support Frame

Horizontal Beam


24 CMA Tower Riyadh, Kingdom of Saudi Arabia

Acrylic Crystalline Components Sign Type FS and FL

Acrylic Component on Sign Type FS

Attach to pegs

4

The acrylic used shall be clear and without any hints of color cast or frosting. Diamond polish all surfaces for a clear, glossy finish allowing light to pass through unhindered. The color and graphic comes from the crystalline graphic film (see section on Crystalline Graphic Film) and is sandwiched in between the acrylic and the diffuser backer. The entire gem-stone portion of the sign is comprised by two acrylic groups (each with 2 acrylic elements) and joined by chemical welding to join as one. Each acrylic element must be cut and polished to fit on sign body precisely without open gaps or uneven seams. Prototyping and testing is crucial to acquire accurate measurements for final production.

28

Clear acrylic piece A

Diffuser backer piece B

Crystalline graphic film

Viewing Direction

Drilled openings

4

Acrylic Component 1 — Top Detail

28

Scale NTS

2

28

This detail is to be mirrored and repeated on the opposite side of the sign. Clear acrylic piece A

Drilled openings

5

28

Attach to pegs

Viewing Direction

3

2

Acrylic Component 1

28

Scale NTS

Crystalline graphic film Diffuser backer piece B

28

Surface to chemical weld to Acrylic Group 2 Attach to pegs

1

Acrylic Group Isometric

3

Acrylic Component 2

5

Acrylic Component 1 — Bottom Detail

28

Scale NTS

28

Scale NTS

28

Scale NTS


25 CMA Tower Riyadh, Kingdom of Saudi Arabia

Crystalline Acrylic Components Relevant for Sign Type FS

2

30

Exterior cabinet

Support frame

Acrylic Group 1

Open space

Acrylic

Peg

Diffuser

Welded

Seam using chemical welding to join Acrylic Component 1 and 2

Stopper

Film

Crystalline graphic film; vertical strip Base skirt

2

30

Acrylic Group 2

LED

Support frame to be extended and bolted to ground

Situated at the bottom Crystalline graphic film at the underside of the acrylic; horizontal strip

1

Isometric View

2

Detail View

30

Scale NTS

30

Scale NTS

Exterior cabinet


26 CMA Tower Riyadh, Kingdom of Saudi Arabia

Access Panels for Service and Maintenence Sign Type FS

Accessibility to Internal Components

Sign type FS has two access portals for servicing and maintenance.

Side Access Panel

Top Access Panel

Side Access Panel

Tab

Located at the side opposite from the acrylic components.

Tab Welded to side access panel

Countersink fasteners; install flush with surface

Top Access Panel The top access panel is mainly for access to the LED

This port allows the technician to access components

running vertically along sign. Mount LED on sliding tracks

located at the bottom of the sign where it may be difficult

for the ability to slide LED vertically out without complete

to reach from the top access port.

disassembly of sign.

Countersinking fasteners install flush to the surface of the

Install countersinking fasteners flush to the surface of the

detachable panels. The positions of the fasteners to align

detachable panel. The positions of the fasteners to center

on the central support beam. Space out evenly (avoid

align along the top of the central support beam and space

positioning fasteners over etched lines). Allow for an

Support Frame

additional 10mm diameter fastener at the bottom of the

out evenly. Use 10mm diameter fasteners and increase quantity of fasteners if structurally necessary. Fasteners to

panel and install firmly to support beam. Fastener to match

match finish of the steel panel. The top access panel

finish of the steel panel.

compressed down to secure the side access panel.

Attach Z Clips to support frame

Attach side access panel with Z Clips (see section on Z Clips)

English Legend

English Legend

Information

Information

Main Lobby

Main Lobby

Information

Information

Information

Fastener

Information

Bottom LED on Sliding Tracks

Mount LED lights to a horizontal sliding track for ease of maintenance.

Vertical LED on Sliding Tracks Mount LED lights to vertically sliding tracks for ease of maintenance.

Divide LED lights into sections if ceiling height is low. Support Frame

1

Isometric View

2

Isometric View

31

Scale 1:15

31

Scale 1:15


27 CMA Tower Riyadh, Kingdom of Saudi Arabia

Wall Mounted Elevator Kiosk [EL] [ER] Measurements, Descriptions, and Construction Details Measurements in millimeters Fasteners Heat vents Touch screen flush

20

100mm

16mm

46mm

0m

m

Touch screen flush

1

Elevator Monitor Facing Left Plan View

2

Elevator Monitor Facing Right Plan View

3

Elevator Monitor Facing Right Bottom View

32

Scale 1:5

32

Scale 1:5

32

Scale 1:5

200mm Elevator Available Enter Level Number

Elevator Available

200mm

Enter Level Number

Enter Level Number Enter Level Number

35

1

2

3

4

5

6

7

8

9

0

This sign type is essentially a structure to house the hardware provided by the elevator consultant. The top surface of screen is completely exposed for touch-sensitive operation. Seams should be kept to a minimum and no open gaps of more than 1mm are acceptable. Use additional mounting reinforcement (hidden from view) if necessary from an engineering standpoint. Edges are to be beveled and smoothed-out; leaving no sharp edges that may cause injuries. If components are manufactured separately, the overall finish and color of material must be visually identical after assembly. Hardware and frame must be configured to fit properly and securely. Production of a full-scale, working prototype is HIGHLY RECOMMENDED for this sign type to test for structural durability, functionality, and aesthetic quality. Electronic and Digital Components Reference Elevator Package for hardware specifications. Signage fabricator responsible for frame and structural detail.

Elevator Available

Elevator Available

Fabrication Notes & Requirements

E N T E R

4

Elevator Monitor Flat Elevation

5

Front View

6

Elevator Monitor Facing Left

32

Scale 1:5

32

Scale 1:5

32

Scale 1:20


28 CMA Tower Riyadh, Kingdom of Saudi Arabia

Wall Mounted Elevator Kiosk [EL] [ER] Material Identification Material Identification Refer to Material Identification Section

A

Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish.

MAT

SS

MAT

EG

A B B

C

1

Plan View for Material Identification

33

Scale NTS

C

A

Elevator Available

Elevator Available

Enter Level Number

Enter Level Number

A

B

B

2

Isometric for Material Identification

33

Scale NTS

Faceted Crystalline Pattern Faceted crystalline pattern to be etched and filled on stainless steel structure (see section of Faceted Crystalline Pattern for details). Electronic Hardware Consult elevator consultant for more information on hardware.


29 CMA Tower Riyadh, Kingdom of Saudi Arabia

Freestanding Elevator Kiosk [EK] Measurements, Descriptions, and Construction Details Measurements in millimeters

Fabrication Notes & Requirements

237

20

E l e v a t o r Av a ila b l e Elevator Available E n t eEnter r Le vLevel e l N uNumber mber 1

2

3

4

5

6

7

8

9

0

E N T E R

20

0

200

Elev a tor Av a ila ble Elevator Available Level EnteEnter r Leve l N uNumber mber

1

2

3

4

5

6

7

8

9

0

E N T E R

3

Plan View

35

Scale 1:15

Electronic and Digital Components Reference Elevator Package for hardware specifications. Signage fabricator responsible for frame and structural detail.

225

770

1045

1210

35

200

12

30

5

Screen

This sign type is essentially a structure to house the hardware provided by the elevator consultant. The top surface of screen is completely exposed for touch-sensitive operation. Seams should be kept to a minimum and no open gaps of more than 1mm are acceptable. Structure should be symmetrical and structurally sound. Use additional structural reinforcement (internal and hidden from view) if necessary from an engineering standpoint. Edges are to be beveled and smoothed-out, leaving no sharp edges that may cause injuries. If components are manufactured separately, the overall finish and color of material must be visually identical after assembly. Hardware and frame must be configured to fit properly and securely. Secure sign structure to ground using expansion bolts. Production of a full-scale, working prototype is HIGHLY RECOMMENDED for this sign type to test for structural durability, functionality, and aesthetic quality.

10

1

Elevator Kiosk

2

Side View

4

Footprint

35

Scale 1:15

35

Scale 1:15

35

Scale 1:15


30 CMA Tower Riyadh, Kingdom of Saudi Arabia

Freestanding Elevator Kiosk [EK] Material Identification Material Identification

Ele

va

to

En

r

a Av

Le ter

v

ila

Nu el

mb

Ele

ble

En

er

B

3

2

6

1

5 8

E

N

T

E

rL e 2

4 7

ve

lN u

T

mb

B ail

ab

le

Refer to Material Identification Section

A

er

6 9

N

rA v

3

8 E

R

to

5

0

0

7

te

1

9

4

va

E

A

R

B

A

A

1

Isometric for Material Identification

36

Scale NTS

A

Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish. Electronic Hardware Consult elevator consultant for more information on hardware.

MAT

SS


31 CMA Tower Riyadh, Kingdom of Saudi Arabia

Freestanding Elevator Kiosk [EK] Isometric of Structure Geometry and Internal Details 3

37

Open and exposed to touch screen device

Open and exposed to touch screen device

Ventilation

Opening for electronic and data connections

Expansion bolts Open to ground

1

Isometric Left

2

Isometric Right

3

Isometric Section Cut

4

Isometric Rear-Right

37

Scale NTS

37

Scale NTS

37

Scale NTS

37

Scale NTS


32 CMA Tower Riyadh, Kingdom of Saudi Arabia

Freestanding Elevator Kiosk [EK] Section Cuts and Details

1

39

Bending angles: 0.25mm radius

Internal support; drawing shows approximate location only; consult structural engineer

Front Elev a tor Av a ila ble Elevator Available

Internal support and cross brace; drawing shows approximate location only; consult structural engineer

Internal support and cross brace; drawing shows approximate location only; consult structural engineer

Level EnteEnter r Leve l N uNumber mber

35

1

2

3

4

5

6

7

8

9

0

E N T E R

4

38

3

38

2

38

Open interior

Open interior

Open interior

3mm stainless steel skin

3mm stainless steel skin

3mm stainless steel skin

Front

Front

Front

1

Location of Section Cuts

2

Section Cut

3

Section Cut

4

Section Cut

38

Scale NTS

38

Scale 1:3

38

Scale 1:3

38

Scale 1:3


Section View

Scale 1:4 .5

Expansion bolts

Opening for electrical supply

Open to cabinet below for electrical and data connections

43

Approximate location of surface of touch screen. 42° viewing angle

Expansion bolts anchor to ground

Base plate; 5mm thick

5 mm diameter fastener

Internal support tube and cross brace; drawing shows approximate location/size only; consult structural engineer

3mm thick stainless steel structural shell

Removable fasteners for hardware enclosure to detach completely

Hardware enclosure: 1.5mm stainless steel skin

Freestanding Elevator Kiosk [EK]

5

1

39 770 30

Space open for installation of electronic hardware. Current dimensions to accommodate for standard 200mm x 200mm screen size. Note: Consult technician for exact configuration of electronic hardware (for exact fit) prior to fabrication

16

33

CMA Tower Riyadh, Kingdom of Saudi Arabia

Section Cuts and Details


34 CMA Tower Riyadh, Kingdom of Saudi Arabia

Freestanding Elevator Kiosk [EK] Access Panels for Service and Maintenence

Head enclosure to house electronic hardware

Accessibility to Internal Components

Surface for ventilation

3

The interior of the sign type EK can be accessed through a detachable hatch located at the rear of the kiosk, and the hardware enclosure housing the electronic hardware is fully detachable.

40

Hardware Enclosure

Additional surface for ventilation Note: Confirm dimension in drawings with actual dimensions of hardware prior to fabrication

Hardware Enclosure This structure houses the primary hardware of the kiosk in which the screen is operated from the opening of the enclosure. The electronics shall be attached securely to the hardware enclosure using custom configurations specific to the hardware used. Grooves are cut on the rear surface of the enclosure for heat dissipation; see pattern of ventilation grooves below:

Open interior for wiring and data connectors. Space available for storage of additional hardware Detachable

40

Detachable hatch

4

40

2

Access Panel

Note: Increase area for ventilation grooves as required by hardware

Attach using 5mm diameter fastener

3

Ventilation Details

40

Scale NTS

Access Panel

Drilled opening

Stainless steel detachable hatch to fit seamlessly and conforming to the geometry of the kiosk. Attach using small, inconspicuous, 5mm diameter fasteners evenly spaced along the edges of the hatch. Route out a portion of both connecting surfaces at the joints to minimize the visibility of a seam by overlapping them. 5mm fastener

Overlapping joints

1

Details of Hardware Enclosure and Access Portal

2

Details of Hardware Enclosure and Access Portal

4

Details of Surface for Fastener

40

Scale NTS

40

Scale NTS

40

Scale NTS


35 CMA Tower Riyadh, Kingdom of Saudi Arabia

Table Map [TM] Measurements, Descriptions, and Construction Details Measurements in millimeters

Fabrication Notes & Requirements 850

L E V EL 1 Men’s Restroom Escalator Information

North Entrance

Elevator to CMA Levels Elevator to Levels 00-00

472

Elevator to Levels 00-00 Elevator to Parking Podium Levels Elevator Security Check

2

Auditorium

1

Green Room

2

VIP Lounge

3

Legend Here

4

Legend Here

5

Legend Here

6

Legend Here

7

Legend Here

8

Legend Here

9

You Are Here

South Entrance 1 3

Quick Reference Security Desk Tower Information Telephone Director y

1

46

0

70

55 LE VEL 1 Men’s Restroom Escalator Information

North Entrance

Elevator to CMA Levels Elevator to Levels 00 - 00 Elevator to Levels 00 - 00

3

Plan View

41

Scale 1:15

Elevator to Parking Podium Levels Elevator Security Check

2

Auditorium

1

Green Room

2

VIP Lounge

3

Legend Here

4

Legend Here

5

Legend Here

6

7 8 9

South Entrance 3

Quick Reference Secur it y Desk Tower Infor mation Telephone Direc tor y

123- 4567 123- 4567 123- 4567

500

Legend Here Legend Here Legend Here

You Are Here

1

545

472

771

1150

850

1

Movable Stanchion

2

Right Side View

4

Footprint

41

Scale 1:15

41

Scale 1:15

41

Scale 1:15

123-4567 123-4567 123-4567

This sign type is essentially a structure to house a light box with a removable Duratrans graphic. Seams should be kept to a minimum and no open gaps of more than 1mm are acceptable. Structure should be symmetrical and structurally sound. Use additional structural reinforcement (internal and hidden from view) if necessary from an engineering standpoint. Edges are to be beveled and smoothed-out, leaving no sharp edges that may cause injuries. If components are manufactured separately, the overall finish and color of material must be visually identical after assembly. Secure sign structure to ground using expansion bolts. Production of a full-scale, working prototype is HIGHLY RECOMMENDED for this sign type to test for structural durability, functionality, and aesthetic quality. Backlit Display (Light Box Display) Use low heat light sources such as LED. 6000K white balance. Evenly distribute light without hot or dead spots on the display. Output map graphics at high resolution on Duratrans substrate.


36 CMA Tower Riyadh, Kingdom of Saudi Arabia

Table Map [TM] Material Identification Material Identification Refer to Material Identification Section

A

B

A

B

Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish. Structure Side (Left And Right) Stainless steel marine grade type 316 with satin, medium horizontal brush finish.

MAT

SS

MAT

SS

MAT

DO

MAT

GL

Faceted crystalline pattern to be etched and filled on stainless steel structure (see section of Faceted Crystalline Pattern for details).

A

C C

D

Digital Output High resolution, high quality digital map artwork on Duratrans substrate.

B D Anti-Glare Optical Glass 10mm thick optical glass serves as protective glass to digital output. Must be optically clear without detracting from image quality. Bevel and finish all edges.

A

1

Table Map Rear View

2

Table Map Front View

42

Scale NTS

42

Scale NTS

MAT

EG


37 CMA Tower Riyadh, Kingdom of Saudi Arabia

Table Map [TM] Measurements, Descriptions, and Construction Details

Fastener

Display bezel

Surface for ventilation grooves if applicable; remove etched pattern

Remove top glass panel to replace map graphic

Rear Access Panel

Display Header Access

Countersinking fasteners install flush to the

Countersinking fasteners install flush to the

surface of the detachable panel. Space out

side of the display bezel. Avoid positioning

evenly along the edge of the panel. Allow for six

fasteners over etched lines. Allow for

10mm diameter fasteners and increase quantity

approximately six 10mm diameter fasteners

of fasteners if structurally necessary. Fasteners

and increase quantity of fasteners if

to match finish of the steel panel.

necessary. Fasteners to match finish of the display bezel.

1 44

Rear Isometric View

2

Isometric View

Scale NTS

44

Scale NTS


38 CMA Tower Riyadh, Kingdom of Saudi Arabia

Table Map [TM] Measurements, Descriptions, and Construction Details

Note: Display header is muted for illustration purpose Surface

13

107

616

LE VEL 1

Escalator Information

North Entrance

Elevator to CMA Levels

10

10

Men’s Restroom

Elevator to Levels 00 - 00 Elevator to Levels 00 - 00 Elevator to Parking Podium Levels Elevator Security Check

2

1 2

VIP Lounge

3

Legend Here

4

Legend Here

5

Legend Here

6

Legend Here

7

Legend Here

8

Legend Here

9

You Are Here

South Entrance 1 3

Surface

Quick Reference Secur it y Desk

6

123- 4567

Tower Infor mation Telephone Direc tor y

123- 4567

Surface

123- 4567

12

Surface

2

Surface

207

10

Surface

14

500

500

178

Surface

292

Auditorium Green Room

Surface

2

Surface

4

Surface

8

10

176

Surface

1

213

86

275

86

213

Surface

7

Surface

Surface

11

3

145

30

Surface

Surface

3

145

Surface

5

152

Surface

9

110

320

11

110

1

Front View

2

Right Side View

3

Rear View

4

Left Side View

45

Scale 1:10

45

Scale 1:10

45

Scale 1:10

45

Scale 1:10

152


1 Section View

46 Scale 1:4 Expansion bolts

Internal Support Tube Drawing shows approximate location/size only; consult structural engineer

Reading surface: see Reading Surface Composite for details

Base plate

3mm exterior skin

Internal folds of exterior skin

3mm exterior skin

Support platform

Support platform

3mm exterior skin

Open space

39

Table Map [TM] CMA Tower Riyadh, Kingdom of Saudi Arabia

Measurements, Descriptions, and Construction Details


40 CMA Tower Riyadh, Kingdom of Saudi Arabia

Table Map [TM] Measurements, Descriptions, and Construction Details

Exterior Fastener Exterior Fastener 10mm diameter. Install inconspicuously and flush with surface. Match finish with enclosure. Locking surface enclosure to bottom enclosure

Open window Surface Enclosure Stainless steel, slightly larger than bottom enclosure. Fits over the top bottom enclosure

LE VEL 1 Men’s Restroom Escalator Information

North Entrance

Elevator to CMA Levels Elevator to Levels 00-00 Elevator to Levels 00-00

2

Elevator to Parking

47

Podium Levels Elevator Security Check

1

Section View

47

Scale 1:10

2

Auditorium

1

Green Room

2

VIP Lounge

3

Legend Here

4

Legend Here

5

Legend Here

6

Legend Here

7

Legend Here

8

Legend Here

9

You Are Here

South Entrance 1 3

Quick Reference Security Desk Tower Information Telephone Directory

123-4567 123-4567 123-4567

Exterior Fastener 10mm diameter. Install inconspicuously and flush with surface. Match finish with enclosure. Locking surface enclosure to bottom enclosure

LEV M en

Elev Elev Elev

Podi

Fastener

Map Graphic

Rubberized Cushion >2mm thick. Placed at contact points of metal and glass

Diffuser Panel

Surface Enclosure

V IP Lege Lege Lege Lege

Fastener 15mm diameter. Install through glass panel and map graphics and attach to support platform below. Flush with surface

Support Platform

Lege Lege

nd

nd

H er

nd

H er e

nd

H er e

nd

H er

e

nd

H er e

Loun

H er e

e

Roo ge

ri ty

itori

ato

r to

ato

r to

CM

A Le

ls 00

ls 00

Pa rk

ev at

Che

r to

Leve

Leve

r to

ls El

ato

Info

rmat

es tr

lato

oom

EL

1

r

ion

vels

-0 0

-0 0

ing

or

ck

um 1

m

N En o

2

tra

3

rt h

nce

4 5

6

2

7 8

9

1

3

You

Are

He

re

SEnou tra

Q ui ck Re Se cu fe re nce To w rit y D Te le er In fo es k rm ph on e D at io n ire ct or y

Optical Glass Panel 10mm thick

Exterior Locking Fastener

Bottom Enclosure

Leve

Secu

en

ato

Elev um

Aud G re

Optical Glass Panel

’s R

Esca

th

nce

12 3-

4567 12 345 12 3- 67 4567

Map Graphics Printed on Duratrans (translucent substrate)

Glass Support Platform

LED Lights

Diffuser Panel 5mm thick and directly above LED light source Support Platform Constructed to support the compression and weight of glass panel

LED Lights

2

Section View

3

Plan View

47

Scale 1:5

47

Scale NTS

Bottom Enclosure Attached to base structure, tilted at viewing angle

Support Platform


41 CMA Tower Riyadh, Kingdom of Saudi Arabia

Table Map [TM] Measurements, Descriptions, and Construction Details

Front

Front

Internal support; drawing shows approximate location only; consult structural engineer

Bending angles: Rounding of edges are tolerable. Form edges at sharpest possible tolerance

Internal support

Open interior

Open interior

3mm stainless steel skin

2

Section Cut

4

Section Cut

49

Scale 1:3

49

Scale 1:3

Front

5

Front

49

Internal support

Internal support

4

49

3

49

Internal support; drawing shows approximate location only; consult structural engineer

2

49

Open interior

Open interior

1

Location of Section Cuts

3

Section Cut

5

Section Cut

49

Scale NTS

49

Scale 1:3

49

Scale 1:3


42 CMA Tower Riyadh, Kingdom of Saudi Arabia

Movable Stanchion [MS] Measurements, Descriptions, and Construction Details Measurements in millimeters

Fabrication Notes & Requirements 230

256

Meeting in session

Do Not Enter

5 33

A4 paper insert

A4 paper insert

Head base

1

53

Meeting in session

3

Plan View

50

Scale 1:15

Wheel Mechanism Use mechanism with the ability to lock wheels when stationary. Locking lever located at the bottom of the structure or at the base and shall be made accessible to operator. Covered wheels with padding to protect floor surfaces from damages or scuffs. Use wheels of neutral colors and position wheels inboard within structure for low visibility.

Do Not Enter

285

256

930

995

1140

Wheel

Base

230

10

1

Movable Stanchion

2

Right Side View

4

Footprint

50

Scale 1:15

50

Scale 1:15

50

Scale 1:15

Seams should be kept to a minimum and no open gaps of more than 1mm are acceptable. Structure should be symmetrical and structurally sound. Use additional structural reinforcement (internal and hidden from view) if deemed necessary from an engineering standpoint. Edges are to be beveled and smoothed-out, leaving no sharp edges that may cause injuries. If components are manufactured separately, the overall finish and color of material must be visually identical after assembly. Production of a full-scale, working prototype is HIGHLY RECOMMENDED for this sign type to test for structural durability, functionality, and aesthetic quality.


43 CMA Tower Riyadh, Kingdom of Saudi Arabia

Movable Stanchion [MS] Material Identification Material Identification Refer to Material Identification Section C A

A B B

C

A

1

Isometric for Material Identification

51

Scale NTS

Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish. Clear Acrylic Clear Acrylic serves as protective glass to paper insert. Must be optically clear without detracting from image quality. Bevel and finish all edges. Crystalline Facet Exposed to view behind acrylic panel. All films are laminated together and sandwiched between acrylic block and opaque white backing (see section of Crystalline Graphic Film for details). Exposed to view behind acrylic panel.

MAT

SS

MAT

CA

MAT

CA

MAT

CF


44 CMA Tower Riyadh, Kingdom of Saudi Arabia

Movable Stanchion [MS] Measurements, Descriptions, and Construction Details 16

75

20

Wheel 75

3mm exterior skin

Lever to activate wheel locking mechanism to back wheel; accessible to operator 25

70

16

40

Meeting in session

257

50

Head base

40

A4 paper insert Clearance from wheel 30

Lever to activate wheel locking mechanism to front wheel; accessible to operator

35

Do Not Enter Base plate

14

Overhang

10

210

10

115

1

Plan View

2

Bottom View

52

Scale 1:2

52

Scale 1:2

16


45 CMA Tower Riyadh, Kingdom of Saudi Arabia

Movable Stanchion [MS] Measurements, Descriptions, and Construction Details Return fold

10

Clear acrylic surface cover (polished with diamond cut finish)

Clear acrylic surface cover (clear polished finish)

Reveal cut 1 3

A4 insert

20

Metal plate (with reveal cut)

Clear acrylic

Fastener installs here Position of fastener

Crystalline graphic film

A4 insert

Fastener

Insert stopper, clear acrylic adhered to metal plate

Insert stopper

Metal plate (with reveal cut)

Head base

Clear acrylic

Crystalline graphic film

1 54

Head Base Composition — Right Side View

2

Head Base Composition

Scale 1:2

54

Scale NTS

Head base


46 CMA Tower Riyadh, Kingdom of Saudi Arabia

Movable Stanchion [MS] Measurements, Descriptions, and Construction Details

109

109

105

Note: Allocate space at coverging and turning corners to accommodate for bending/folding of metal sheet

Surface

1

Surface

Surface

8

1 58

16

Surface

Surface

3

Surface

2

107

Front View

2

Scale 1:8

58

16

7

Surface

4

146

Surface

5

Surface

2

107

Note: Allocate space at coverging and turning corners to accommodate for bending/folding of metal sheet

Surface

4

123

107

Right Side View

3

Scale 1:8

58

Surface

6

16

Surface

6

107

8

146

16

Rear View

4

Left Side View

Scale 1:8

58

Scale 1:8

123


47 CMA Tower Riyadh, Kingdom of Saudi Arabia

Double-Sided Digital Display [DD] Measurements, Descriptions, and Construction Details Measurements in millimeters 1

Fabrication Notes & Requirements

63

1100 600

863

70� LED Monitor Portrait orientation with viewable area of 1545 x 863mm

1

2430

1545

62

Seams should be kept to a minimum and no open gaps of more than 1mm are acceptable. Structure should be symmetrical and structurally sound. Use additional structural reinforcement (internal and hidden from view) if necessary from an engineering standpoint. Exposed edges are to be beveled and smoothed-out, leaving no sharp edges that may cause injuries. If components are manufactured separately, the overall finish and color of material must be visually identical after assembly. Protective glass or any part of the structure should not detract from picture quailty of the LED monitors. Secure sign structure to ground using expansion bolts. Production of a full-scale, working prototype is HIGHLY RECOMMENDED for this sign type to test for structural durability, functionality, and aesthetic quality. Electronic and Digital Components AV consultant to provide LED monitor(s). Reference AV package for monitor and data/electrical requirements. Signage fabricator responsible for frame and structural detail. General LED monitor hardware specifications (for reference only): High Brightness, 24/7 rated, 1080p resolution, and international power. Adjustment to monitor made by using remote.

537

Crystalline Graphic See section on Crystalline Graphic Film. Backlit with internal LED illumination. 6000K white balance.

1

Double-Sided Digital Display

59

Scale 1:20

1360

2

Left Side View

59

Scale 1:20


48 CMA Tower Riyadh, Kingdom of Saudi Arabia

Double-Sided Digital Display [DD] Section Cuts and Details

600

Ventilation

Ventilation

Plan View Scale 1:15

51

1 60

111

Ventilation

432

600

537

1360

Opening for electrical and data feed

Opening for electrical and data feed 278

2

Bottom View

3

Bottom Detail

60

Scale 1:15

60

Scale 1:10

804


49 CMA Tower Riyadh, Kingdom of Saudi Arabia

Double-Sided Digital Display [DD] Material Identification

Etched and filled line 3mm width

Etched and filled line 3mm width

A

A

Material Identification Refer to Material Identification Section

A

B

B

B

A Etched and filled line 3mm width

Etched and filled line 3mm width

C

A

Identical configurations and specifications are identical on both sides of sign structure

1

Isometric View for Material Identification

61

Scale NTS

Structure Side (Left And Right) Stainless steel marine grade type 316 with satin, medium horizontal brush finish.

MAT

SS

MAT

SS

MAT

EG

MAT

CA

MAT

CF

MAT

GL

Faceted crystalline pattern to be etched and filled on stainless steel structure (see section of Faceted Crystalline Pattern for details).

E

D

Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish.

C

Crystalline Facet Internally illuminated (see section on Crystalline Facet for further information).

D Anti-Glare Optical Glass 5mm thick optical glass serves as protective glass to LED monitor. Must be optically clear without detracting from image quality. Bevel and finish all edges.

E

HD LED Monitor Two High-Definition 16:9 monitors of 70� screen size. Portrait orientation. Screens are positioned back-toback against each other allowing for viewing from front and back. Allow for adequate spacing in-between for heat to dissipate. Original bezel or frame of the monitors may have to be removed prior to monitor mounting.


50 CMA Tower Riyadh, Kingdom of Saudi Arabia

Double-Sided Digital Display [DD] Section View equal

Open Space

equal

Cabinet Body Formed from 3mm thick stainless steel

Air Circulation Open Space Located behind LED monitors for air to circulate and clearance for wires and cables

Clear Optical Protective Glass

Rubber Spacer To provide separation between glass and monitor

198

Monitor Brackets Custom formed brackets securing LED monitors to structure. Shape of bracket conforms to shape of the monitor. Do not block heat vents

HD LED Monitor A 198mm in thickness

equal

Tube Support Frame Main support for sign structure and expansion bolted to ground

175

Whisper Micro Fans

Z Clip (Side) Attach side panels to support frame (see section on Z Clips)

equal

Horizontal Beams Stainless steel beams for attachment of Whisper Fans and other accessories 198

HD LED Monitor B 198mm in thickness

Stainless Steel Panel (Left and Right Side) 3mm thick stainless steel panel with etched pattern

Monitor Brackets

Z Clips Attach side panels to central support (see section on Z Clips)

1

Section View

62

Scale 1:5

Clear Optical Protective Glass 5mm thick and non-glare. For protection of LED monitors from impact or touch

Rubber Spacer

Cabinet Body

NOTE: Use LED manufacturer’s mounting/electronic hardware whenever possible; modify hardware to use in sign


Section View

Scale 1:8 Clear Optical Protective Glass

Open space

Monitor Bracket Position to coordinate with configuration of monitor

Air Intake Gap Approx. 13mm wide; open to draw cool air to aid heat dissipation

Filter Foam Attached at the opening of air intake gap; hidden from view

Stainless Steel Bolt Attach monitor support tray to tube support frame

Monitor Support Tray

1

63 Open space

Open space

Fastener

140

equal

294

equal

140

Exterior Cabinet 3mm thick stainless steel

68

2

Exterior Cabinet 3mm thick stainless steel

Whisper Micro Fan (Bottom Row)

Monitor Bracket

Clear Optical Protective Glass

Z Clip Side B Attached to horizontal beam (on both sides)

Z Clip Side A Attached to monitor unit (on both sides)

LED Monitor Unit Approx. 198mm thick

LED Monitor Unit Approx. 198mm thick

Tube Support Frame Approx. 198mm thick

Spacers Occupies space between monitor and optical glass

Whisper Micro Fan Draw heat upwards to exiting heat vent

Top End Cap Panel 3mm stainless steel with cut through heat vent. Attach with mechanical fasteners

51

Double-Sided Digital Display [DD] CMA Tower Riyadh, Kingdom of Saudi Arabia

Section View

2430


52 CMA Tower Riyadh, Kingdom of Saudi Arabia

Double-Sided Digital Display [DD] Monitor on Support Frame

Tube Support Frame

LED Monitor Unit Monitor Brackets

Monitor Brackets LED Monitor Unit

Monitor exposed to view; viewable area LED Monitor Unit

Monitor Brackets Support Tray Additional support platform for monitor to rest on

Space for power supply, transformers

Crystalline Facet Internally illuminated

1 64

Composite — Isometric View

2

Scale NTS

64

Exterior Cabinet — Isometric View

3

Interior Frame Structure — Isometric View

Scale NTS

64

Scale NTS

Space for power supply, transformers, etc.


53 CMA Tower Riyadh, Kingdom of Saudi Arabia

Double-Sided Digital Display [DD] Monitor Mounting Details Fasteners Tube Support Frame Provide main integral support for entire structure

Fastener Monitor Bracket Detachable with fasteners; mounted to tube support frame

Tube Support Frame

Z Clip One component attached to frame and mechanically locks to the Z Clip at the rear of monitor

198

Length to accommodate thickness of LED monitor (allow for cushion lining)

Viewing Direction

1 65

Internal Support Only — Isometric View

2

Scale NTS

65

Isometric View of Frame and Monitor Brackets

3

Monitor Bracket Detail — Plan View

Scale NTS

65

Scale 1:3

Protective Lining Cushion at contact points of monitor and monitor bracket

Monitor Bracket


54 CMA Tower Riyadh, Kingdom of Saudi Arabia

Double-Sided Digital Display [DD] Heat Dissipation within Structure

Whisper Micro Fans

Heat Path

Mount to horizontal beam and detachable for ease of replacement; silent motor to reduce mechanical noises

Internal Air Circulation and Heat Dissipation Heat dissipation path located in the open spaces in between the rear of the monitor units where most of the heat is generated from the LED monitor units. The flow is facilitated by eight electronic Micro Fans distributed in three rows (top, middle and bottom). Fans at the lower portion help guide the heated air upwards, and the fans at the very top will provide the final push for heated air to exit out into the exterior of the structure through the top vents. Allow open gaps at bottom underneath the monitors for drawing in cool exterior air. Fans should be made detachable for replacement and maintenance purposes. All loose wires (from monitors, fans, etc.) must be attached to support frame for organization.

Heated air exits from open vents located at the top of sign structure

Top Row (2 fans)

Horizontal Beam Heat Path

Heat dissipation path Whisper Micro Fans

Fans draw heated air upwards and away from LED monitor units

Whisper Micro Fans Heat vents

Middle Row (3 fans)

Whisper Micro Fans

Heat Path

Heat dissipation path located in the open spaces in between the rear of the monitor units

Electrical wires

Bottom Row (3 fans)

Open gaps in exterior cabinet allows fans to draw cool air into dissipation path

Internal support frame

Exterior cabinet

1

Internal Support Only — Isometric View

2

Internal Support Only — Front View

3

Internal Support Only — Isometric View

66

Scale NTS

66

Scale NTS

66

Scale NTS


55 CMA Tower Riyadh, Kingdom of Saudi Arabia

Double-Sided Digital Display [DD] Details of Access Panels

Fastener Mechanical fasteners compress all components to frame

Mechanical Grip Inserted into grip catch on both sides. Secure and lock exterior cabinet to support frame. Use allen wrench to tighten

Top Access Panel

Grip Catch Catches mechanical grip and attached to support frame; tighten connection using allen wrench

Tab Welded to side access panel

Surface on support frame for installation of mechanical fasteners

Fastener Side Access Panel

Z Clip installation on this surface (see section on Z Clips)

Z Clip

Top Access Panel Open heat vent for exiting air

Grip Catch Catches mechanical grip and attached to exterior cabinet; tighten connection using allen wrench Tab Welded to side panel as a surface to receive mechanical fasteners above

Side Access Panel Attach to support frame using Z Clips. Welded tab at top for mechanical fasteners Z Clips installation on this surface (see section on Z Clips)

Angled side access panel

Note: Use identical details on both sides of sign structure

Open space Secure bottom of exterior cabinet to the lower structure or to ground plate

Support Frame

1

Top Panel and Z Clip Details

2

Isometric

67

Scale NTS

67

Scale NTS


56 CMA Tower Riyadh, Kingdom of Saudi Arabia

Double-Sided Digital Display [DD] Details of Crystalline Facet

equal

equal

LED Light Source

Support Frame Positioning Tab

Fastener

Attach crystalline graphic facet to sign structure

Upper Acryic Bracket

Cabinet Body

3mm thick stainless steel

Filter Foam

Clear Acrylic Block B

Cut from one continuous block of acrylic 15mm thick (repeat detail at opposite side) 88

Use fasteners to attach to bottom of sign structure

Viewing Portion

Direction of Light

Crystalline Graphic Film

Direction of Light

(repeat detail at opposite side)

Clear Acrylic Block A

Cut from one continuous block of acrylic 25mm thick (repeat detail at opposite side)

Exterior Cabinet Body

Positioning Tab

Detachable and adjustable to tightly secure acrylic components and graphic film

Crystalline Graphic Facet

Exterior Cabinet Body

Fastener

Install flush at exposed end

Open Space

Location in relation to the sign structure

Air Intake Gap

Leave open to exterior

1 68

Crystalline Graphic Facet

2

Section View

Scale 1:15

68

Scale 1:3

Lower Acryic Bracket 3mm thick stainless steel

Air Intake Gap

Leave open to exterior


57 CMA Tower Riyadh, Kingdom of Saudi Arabia

Double-Sided Digital Display [DD] Support Frame

Location of support structure within exterior cabinet (shaded in blue)

Monitor Bracket

Monitor Bracket

Tube Support Frame

LED Monitor

Z Clip Attached to horizontal beam

Viewing Direction

Monitor Bracket

Support Tray Lower Support Frame Addtional support directly below of monitor Base Plate and Bolts Plate welded to structure and firmly attached to ground

1

Tube Support Frame

2

View Without Exterior Skin and LED Monitor

3

View Without Exterior Skin and LED Monitor — Right Side View

70

Scale 1:20

70

Scale 1:20

70

Scale 1:20

Z Clip (to monitor) Tube Support Frame


58 CMA Tower Riyadh, Kingdom of Saudi Arabia

Single-Sided Digital Display [SS] Measurements, Descriptions, and Construction Details Measurements in millimeters 1

Fabrication Notes & Requirements

75

1100

365

863

70� LED Monitor Portrait orientation with viewable size at 1545 x 863mm

1

2430

1545

76

Electronic and Digital Components AV consultant to provide LED monitor(s). Reference AV package for monitor and data/electrical requirements. Signage fabricator responsible for frame and structural detail. General LED monitor hardware specifications (for reference only): High Brightness, 24/7 rated, 1080p resolution, and international power. Adjustment to monitor made by using remote.

3

72

Crystalline Graphic See section on Crystalline Graphic Film. Backlit with internal LED illumination. 6000K white balance.

537

1 71

Single-Sided Digital Display Scale 1:20

Seams should be kept to a minimum and no open gaps of more than 1mm are acceptable. Structure should be symmetrical and structurally sound. Use additional structural reinforcement (internal and hidden from view) if necessary from an engineering standpoint. Exposed edges are to be beveled and smoothed-out; leaving no sharp edges that may cause injuries. If components are manufactured separately, the overall finish and color of material must be visually identical after assembly. Protective glass or any part of the structure should not detract from picture quailty of the LED monitors. Secure sign structure to ground using expansion bolts. Production of a full-scale, working prototype is HIGHLY RECOMMENDED for this sign type to test for structural durability, functionality, and aesthetic quality.

1360

2

Left Side View

71

Scale 1:20


59 CMA Tower Riyadh, Kingdom of Saudi Arabia

Single-Sided Digital Display [SS] Material Identification Material Identification Refer to Material Identification Section

Heat vents A

A

A

B

Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish. Structure Side (Left And Right) Stainless steel marine grade type 316 with satin, medium horizontal brush finish. Etched pattern (see section on Faceted Crystalline Pattern).

MAT

SS

MAT

SS

MAT

CA

MAT

GL

MAT

TA

E C

B A

B

D Anti-Glare Optical Glass 5mm thick optical glass serves as protective glass to LED monitor. Must be optically clear without detracting from image quality. Bevel and finish all edges.

A

E

C

A

A

A

1 73

Crystalline Facet Internally illuminated (see section on Crystalline Facet for further information).

Front Isometric for Material Identification

2

Rear Isometric for Material Identification

Scale NTS

73

Scale NTS

HD LED Monitor Two High-Definition 16:9 monitors of approximately 62� screen size. Oriented vertically. Slightly smaller screens are allowed (no smaller than 55�) but adjust bezel around screen proportionally. Screens are positioned back-toback against each other allowing for viewing from the front or back. Allow for adequate spacing between the two monitors for heat to dissipate. Original bezel or frame of the monitors may have to be removed prior to monitor mounting.

MAT

CF


135

67

2mm width

Rear View — Pattern of Heat Ventilations

Scale 1:10 100 1685

1

74 135

10mm diameter

2mm width

Heat Vents

Rear Access Panel Fasteners

125

Fastens to structure and detachable to access LED lights; panel and fasteners to match exterior skin finish and install flush to surface (outlined in blue)

67

90

Rear Access Panel

Heat Vents

440

60

Single-Sided Digital Display [SS] CMA Tower Riyadh, Kingdom of Saudi Arabia

Measurements, Descriptions, and Construction Details


61 CMA Tower Riyadh, Kingdom of Saudi Arabia

Single-Sided Digital Display [SS] Measurements, Descriptions, and Construction Details

Rear Access Panel

Clear Acrylic Block B

Cut from one continuous block of acrylic 15mm thick (repeat detail at opposite side)

Detach to access LED lights

Crystalline Graphic Film

Accessible from the rear of sign structure. Install flush to surface

Fastener

(repeat detail at opposite side)

Clear Acrylic Block A

Cut from one continuous block of acrylic 25mm thick (repeat detail at opposite side)

Fastener

Filter Foam

88

Exterior Cabinet Body

1

Leave open to exterior

Fastens to structure and detachable to access LED lights; panel and fasteners to match exterior skin finish and install flush to surface

Reference details of sign type DD

77

Air Intake Gap

Rear Access Panel

Folded Lip

Isometric

2

Scale NTS

77

Viewing Portion

Rear Isometric View

3

Section View

Scale NTS

77

Scale 1:3

Direction of Light

Positioning Tab

Detachable and adjustable to tightly secure acrylic components and graphic film

Open Space


62 CMA Tower Riyadh, Kingdom of Saudi Arabia

Perforations for Audio Devices Optional Details for Sign Type DD & DS

75 75

310

2

80

Upper Audio Perforations (2) In the shape of a trapezoid of 310mm tall x 75mm wide at the bottom then tapers down to 35mm at the top. The shape to follow the contours of the structure while spacing 15mm away from perforations to edges. Mirror details at opposite side. 210

310 75

210

75

3

80

Lower Audio Perforations (2) In the shape of a parallelogram of 210mm wide x 75mm high. Mirror details at opposite side.

1

Front View — Locations of Audio Perforations

2

Detail of Upper Audio Perforations

3

Detail of Lower Audio Perforations

80

Scale 1:15

80

Scale 1:5

80

Scale 1:5


63 CMA Tower Riyadh, Kingdom of Saudi Arabia

Single-Sided Freestanding Map Directory [FM] Measurements, Descriptions, and Construction Details 1

89

490

Measurements in millimeters

490

150

Fabrication Notes & Requirements

1

Seams should be kept to a minimum and no open gaps of more than 1mm are acceptable. Structure should be symmetrical and structurally sound. Use additional structural reinforcement (internal and hidden from view) if necessary from an engineering standpoint. Edges are to be beveled and smoothed-out; leaving no sharp edges that may cause injuries. If components are manufactured separately, the overall finish and color of material must be visually identical after assembly. Secure sign structure to ground using expansion bolts. Production of a full-scale, working prototype is HIGHLY RECOMMENDED for this sign type to test for structural durability, functionality, and aesthetic quality.

165

90

84

LE VEL 1

840

North Entrance

2 You Are Here

South Entrance 1 3

Viewing Direction

Men’s Restroom Escalator Information Elevator to CMA Levels Elevator to Levels 00-00 Elevator to Levels 00-00 Elevator to Parking Podium Levels Elevator

1

Legend Here

4

Legend Here

7

Green Room

2

Legend Here

5

Legend Here

8

VIP Lounge

3

Legend Here

6

Legend Here

9

2045

2045

Security Check

Auditorium

Quick Reference Security Desk

123-4567

Tower Information

123-4567 Telephone Directory

123-4567

Crystalline Graphic See section on Crystalline Graphic Film. Backlit with internal LED illumination. 6000K white balance. Backlit Display Use low heat light sources such as LED. 6000K white balance. Evenly distribute light without hot or dead spots on the display. Output map graphics at high resolution on Duratrans substrate.

55

55

Base skirt

215

620

620

350

1

Front View

2

Side View

3

Rear View

81

Scale 1:15

81

Scale 1:15

81

Scale 1:15


64 CMA Tower Riyadh, Kingdom of Saudi Arabia

Single-Sided Freestanding Map Directory [FM] Material Identification Material Identification Refer to Material Identification Section

F

A

A

L VE

LE

1

B

B

2

Are

He

C

h ut ance So Entr

re

3

Me

n’s

Re

str

Esc

1

Infor

Ele Ele Ele

vat

vat vat

or

Po

to

or

to

or

Ele diu

Le

or

Leve Se

oo

ala

ma

ls 00

-00

vat

y Ch

4

dit

ee

VIP

or ium

n Ro Lo

12 en

He He He

nd

He He

re

D

C

8

re 9

re

12

3-4

56

7

5 6

re 3-4

56

7

Te

lep

ho

ne

Dir

ect

3-4

56

7

To

we

r Inf

orm

ati

MAT

DO

MAT

GL

MAT

SS

MAT

CA

MAT

EG

MAT

CF

eck

re

re

12

3

ge

fer

nd

gend

nd

Lege

SS

ng

ory

2

om

un

nd

Lege Le

1

Au Gr

Lege

Lege

He

MAT

or

7

nd Lege

SS

-00

Parki

ls Ele

curit

n

vels

00 vels

to

m

tor

tio

A Le

Leve

vat

m

CM

to

Structure Sides and Rear Stainless steel marine grade type 316 with satin, medium horizontal brush finish.

MAT

Faceted crystalline pattern to be etched and filled on stainless steel structure (see section of Faceted Crystalline Pattern for details).

th ance NEntror

You

Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish.

on

ce

Digital Output High resolution, high quality digital map artwork on Duratrans substrate.

Re sk ick De Qu ity cur Se

D Anti-Glare Optical Glass 5mm thick optical glass serves as protective glass to digital output. Must be optically clear without detracting from image quality. Bevel and finish all edges. E

F

E

1

Isometric for Material Identification

82

Scale NTS

D

Base Skirt Stainless steel marine grade type 316 with satin, medium horizontal brush finish. Transparent coating to protect from scuffs and scratches. Crystalline Facet Internally illuminated (see section on Crystalline Facet for further information).


65 CMA Tower Riyadh, Kingdom of Saudi Arabia

Single-Sided Freestanding Map Directory [FM] Access Panels for Service and Maintenence

Fastener

Acrylic Blocks

Fasteners install from top and lock side access panel in place

LED Components

Fastener

Fasteners install from top and lock side access panel in place

LED Cabinet Door

Acrylic Block

(shaded in gray lines)

Fastener

Fasteners install from top and lock side access panel in place

LE

Nor Entr

VE

3mm thick

Open space

Open space

L1

LED Door

Secured by fasteners installed from top and bottom. Act to hold acrylic pieces in position. Remove to access LED. Identical detail at opposite side

th

ance

1

You

3

Are

Her

e

So

ut anceh

Entr

Me

n’s

Res

tro

Esc Ele

Au

Ele

dit

een

VIP

ori

Ro

Lo

um

Ele

1

vat

vat vat

om

ung

Info or

or

Pod

to

Leg

ick Sec Refere urit y De nce sk

Leg Leg 123

-45

end end end

He He He

Tow

er

Info

rma

Lev or

Lev

els

or

atio

0000-

Par

Ele

urit

4

om

alat

rm

A Lev

els

to

els

Sec

re

n

els 00 00

kin

vat

y Ch

g

or

eck

re 5

re 6

67

CM

Lev

vat

ium

3

Qu

to

to

or

Ele

2

e

Welded to side access panel; tab used for installation of fastener

Side Access Panel

2

Gr

Tab

Leg Leg

tion

Leg 123

-45

67

Tel

end end end

He He He

re 7

re 8

re 9

eph

one

Dir

ect

ory

123

-45

67

Side Access Panel

Side Access Panel

On both sides of structure

Fastener

Installs from underneath platform plate and through the LED cabinet door

Welded to tube support frame

Platform

For the primary support for the LED and acrylic components

Side Access Panel 3mm thick

Open space

Z Clip

This component attached to side access panel

Tube Support Frame

Serves as primary support for structure. Platform is welded to frame for support Open space

Tube Support Frame

Serves as primary support for structure. Platform is welded to frame for support. This surface used to attach Z Clips

2

Detail View of Fastener

2

Front Interior View

85

Scale NTS

85

Scale 1:3

Tube Support Frame

Z Clip

This component attached to support frame


66 CMA Tower Riyadh, Kingdom of Saudi Arabia

Acrylic Crystalline Components Sign Type FM

Acrylic Crystalline Component

220

135

40

220

50

The acrylic used shall be clear and without any hints of color cast or frosting. Diamond polish all surfaces for a clear, glossy finish allowing light to pass through. The color and graphic comes from the crystalline graphic film (see section on Crystalline Graphic Film) and is sandwiched in between two pieces of clear acrylic. Both acrylic pieces and graphic film to be cut precisely for an exact fit when fully assembled. Secure all three components tightly to ensure graphic film stays flat without bending. Use metal brackets to compress and fasten all pieces together. Install LED light source behind the acrylic for backlighting effect.

Crystalline Graphic Film Stainless steel structure

Acrylic B Diffuser backer (cut to shape)

Unexposed area of acrylic; secured within structure (shaded)

2

Front View

86

Scale 1:4

Unexposed area of acrylic; secured within structure (shaded)

Exposed area of acrylic (un-shaded)

Crystalline Graphic Film

Viewing Direction

Acrylic A (shaped and formed)

Acrylic B Diffuser backer

34

Compress and fasten pieces tightly

Acrylic A

Viewing Direction

1 86

Isometric View

3

Plan View

Scale NTS

86

Scale 1:4


67 CMA Tower Riyadh, Kingdom of Saudi Arabia

Acrylic Crystalline Components Sign Type FM

Stainless Steel Cover A 3mm thick stainless steel panel, cut and formed to follow the contour of the crown, is used to cover the acrylic, graphic film, and LED lights. The cover plate to be fasten by two 10mm diameter fasteners at opposite ends. Consider using weather sealant (to keep debris out) on the surface that comes into contact with acrylic. Detach cover plate to service LED. Match color and finish to structure.

10mm fastener Cover plate Crystalline acrylic (exposed)

LED lights

Acrylic

1 88

Internal View

2

Composite View

Scale NTS

88

Scale NTS


1 Section View

89 Scale 1:8 840

Base Plate and Expansion Bolts Welded to support frame and attached to ground using expansion bolts

Fastener For attaching exterior cabinet to base skirt

Exterior Cabinet 3mm stainless steel

Tube Support Frame

Light Box Support Bracket Install at the lower portion of lightbox. Resting platform for light box above

Viewing Direction

Open space

Base Skirt Stainless steel protective base

Open space

Exterior Cabinet 3mm stainless steel

Open space

Map Graphic Light Box Approx. 80mm thick

Light Box Bracket Installed at top of light box; holding light box firmly in place. Attached to tube support frame

Platform For the primary support for the LED and acrylic componets

Acrylic Components

LED Lights

68

Single-Sided Freestanding Map Directory [FM] CMA Tower Riyadh, Kingdom of Saudi Arabia

Section View


69 CMA Tower Riyadh, Kingdom of Saudi Arabia

Double-Sided Freestanding Map Directory [FD] Measurements, Descriptions, and Construction Details 1

93

Measurements in millimeters

490 245 1

165

90

91

LE VEL 1

LE VEL 1

North Entrance

840

North Entrance

2 You Are Here

South Entrance

2 You Are Here

South Entrance

1

1 3

3

Men’s Restroom

Men’s Restroom

Escalator

Escalator

Information

Information

Elevator to CMA Levels

Elevator to CMA Levels

Elevator to Levels 00-00

Elevator to Levels 00-00

Elevator to Levels 00-00

Elevator to Levels 00-00

Elevator to Parking

Elevator to Parking

Podium Levels Elevator

Podium Levels Elevator

Auditorium

1

Legend Here

4

Legend Here

7

Green Room

2

Legend Here

5

Legend Here

8

VIP Lounge

3

Legend Here

6

Legend Here

9

Security Check

2045

2045

Security Check

Quick Reference Security Desk

123-4567

Tower Information

123-4567 Telephone Directory

Auditorium

1

Legend Here

4

Legend Here

7

Green Room

2

Legend Here

5

Legend Here

8

VIP Lounge

3

Legend Here

6

Legend Here

9

Fabrication Notes & Requirements Seams should be kept to a minimum and no open gaps of more than 1mm are acceptable. Structure should be symmetrical and structurally sound. Use additional structural reinforcement (internal and hidden from view) if necessary from an engineering standpoint. Edges are to be beveled and smoothed-out; leaving no sharp edges that may cause injuries. If components are manufactured separately, the overall finish and color of material must be visually identical after assembly. Secure sign structure to ground using expansion bolts. Production of a full-scale, working prototype is HIGHLY RECOMMENDED for this sign type to test for structural durability, functionality, and aesthetic quality.

Quick Reference

123-4567

Security Desk

123-4567

Tower Information

123-4567 Telephone Directory

123-4567

Crystalline Graphic See section on Crystalline Graphic Film. Backlit with internal LED illumination. 6000K white balance.

434

Note: This is a doubled-sided structure; identical on both sides

55

55

Base skirt

620

1

Side A — Front View

2

Side View

3

Side B — Front View

90

Scale 1:15

90

Scale 1:15

90

Scale 1:15

Backlit Display Use low heat light sources such as LED. 6000K white balance. Evenly distribute light without hot or dead spots on the display. Output map graphics at high resolution on Duratrans substrate.


70 CMA Tower Riyadh, Kingdom of Saudi Arabia

Double-Sided Freestanding Map Directory [FD] Material Identification Material Identification Refer to Material Identification Section

F

A

A

A VE

LE

LE

Nor Ent

ran

VE

L1

th

You

Yo

3

u Ar

e He

Are

He

ut h

ance So Entr

re

re

So Ent

2

3

uth

ran

Me

n’s

Infor

Ele Ele n’s

Re

str

Esca Ele

Au

Ele

dit

ee

VI P

or

ium

n Ro Lo

Ele

1

vato

vato vato

om

un

Po

diu

3 Qu Se

Le

ick

cu

Inf r to

r to

Re fer en rit y De ce sk

Le Le 12

3-4

56

7

ge ge ge

nd nd nd

He He

we

r Inf

or

ma

He

tio

Le

vato Le

rit

Po

r

4

Lege Le Le Le 3-4

56

7

Te

ge ge ge

nd nd nd

Lege He He He

re 7

ho

ne

8

Au

re

Gr Di

rec

tor

Lege

1

re

9 lep

Leve

vat

m

or

Leve Se

curit

dit

ee

VIP

or ium

n Ro Lo

y Ch

12

y

12

3-4

56

en

He He He

Lege

nd

Lege

nd

He He He

re

3-4

56

7

To

we

r Inf

orm

ati

3-4

56

7

Te

lep

ho

ne

Dir

ect

C

eck

re 8

re 9

re 3-4

56

7

ory

Digital Output High resolution, high quality digital map artwork on Duratrans substrate.

E

Scale NTS

GL

MAT

SS

MAT

CA

MAT

CF

Re sk ick De Qu ity cur Se

7

F

Isometric for Material Identification

MAT

ce

E

1

DO

on

D Anti-Glare Optical Glass 5mm thick optical glass serves as protective glass to digital output. Must be optically clear without detracting from image quality. Bevel and finish all edges.

92

MAT

n

5 6

EG

ng

re re

MAT

or

12

12

3

ge

fer

nd nd

nd

SS

-00

vat

2

om

un

nd

Lege

MAT

-00

Parki

ls Ele

Structure Side (Left And Right) Stainless steel marine grade type 316 with satin, medium horizontal brush finish.

vels

ls 00

to

m

tor

tio

00

7

k

5

12

to

or

diu

D

ng

ec

re

n

to

or

oo

ala

ma

A Le

ls Leve

n

-0 0

vato

y Ch

vat

CM

to

ls

-0 0

rki

vat

or

Ele

or

ve

ls 00 Pa

Ele

vat

m

tio

Le

ls 00

ls Ele

cu

4

lat

ma

A

r to

ve

Se

re

or

ve ve

oo

re

6 To

m

CM

Le

r to

Ele

2

ge

str

Esc

1

Me

Re

ce

SS

Faceted crystalline pattern to be etched and filled on stainless steel structure (see section of Faceted Crystalline Pattern for details).

th ance NEntror

1

Gr

B

B

C

MAT

L1

ce

2

Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish.

Base Skirt Stainless steel marine grade type 316 with satin, medium horizontal brush finish. Transparent coating to protect from scuffs and scratches. Crystalline Facet Internally illuminated (see section on Crystalline Facet for further information).


Section View

Scale 1:8 Base Plate and Expansion Bolts Welded to support frame and attached to ground using expansion bolts

Fastener For attaching exterior cabinet to base skirt

Open space

Exterior Cabinet 3mm stainless steel

Tube Support Frame

Light Box Support Bracket Install at the lower portion of light box. Resting platform for light box above

Viewing Direction

Light Box Bracket

Open space

840

1

93 Acrylic Components

1

FS

eq.

eq.

Expansion Bolts Consult structural engineer for quantity and specifications

Base Skirt Stainless steel protective base

Exterior Cabinet 3mm stainless steel

Open space

Viewing Direction

Map Graphic Light Box — Side B Approx. 80mm thick

Map Graphic Light Box— Side A Approx. 80mm thick

Light Box Bracket Installed at top of light box; holding light box firmly in place. Attached to tube support frame

Platform For the primary support for the LED and acrylic componets

Acrylic Components

LED Lights

71

Double-Sided Freestanding Map Directory [FD] CMA Tower Riyadh, Kingdom of Saudi Arabia

Section View


72 CMA Tower Riyadh, Kingdom of Saudi Arabia

Double-Sided Freestanding Map Directory [FD] Details of Access Panel LED Components

Fastener

Fasteners install from top and lock side access panel in place

Acrylic Blocks Fastener

LED Cabinet Door

Fasteners install from top and lock side access panel in place

Fastener

Acrylic Block

(shaded in gray lines)

Fasteners install from top and lock side access panel in place

Tab

Welded to side access panel; tab use for installation of fastener

Side Access Panel 3mm thick

LE

Nor Entr

VE

Open space

Open space

L1

LED Door

th

ance

Secured by fasteners installed from top and bottom. Act to hold acrylic pieces in position. Remove to access LED. Identical detail at opposite side

2

1

You

3

Are

Her

e

So

ut anceh

Entr

Me

n’s

Res

tro

Esc Ele

Au

Side Access Panel

Gr

Ele

dit

een

VIP

ori

Ro

Lo

um

Ele

1

vat

vat vat

om

ung

e

Info or

or

Pod

to

Leg

ick Sec Refere urit y De nce sk

Leg Leg 123

-45

end

ium

end end

He He He

Tow

er

Info

rma

or

Lev

re

els

to

els

or

atio

0000-

Par

Ele

urit

4

om

alat

rm

A Lev

els

n

els 00 00

kin

vat

y Ch

g

or

eck

re 5

re Leg Leg

tion

Leg 123

On both sides of structure

Lev

Sec

6

67

CM

Lev

vat

3

Qu

to

to

or

Ele

2

-45

67

Tel

end end end

He He He

re 7

re 8

re 9

eph

one

Dir

ect

ory

123

-45

67

Fastener

Side Access Panel

Install from underneath platform plate and through the LED cabinet door

Welded to tube support frame

Platform

For the primary support for the LED and acrylic components

Side Access Panel 3mm thick

Open space

Z Clip

This component attached to side access panel

Tube Support Frame

Serves as primary support for structure. Platform is welded to frame for support Open space

Tube Support Frame

Serves as primary support for structure. Platform is welded to frame for support. This surface for attachment of Z Clips

1

Isometric View

2

Front Interior View

94

Scale NTS

94

Scale 1:3

Tube Support Frame

Z Clip

This component attached to support frame


73 CMA Tower Riyadh, Kingdom of Saudi Arabia

Double-Sided Freestanding Map Directory [FD] Details of Map Graphics Light Box 2

15

435

5

For the operation of hinged door

Movable for easy access for maintenance of interior components

80

Hinged Door

Light Box Cabinet

5

Folded Bezel

Hidden from view

Position Bracket

Extent of glass; hidden from view

Light Box Cabinet

Secure glass panels and graphic in firm position; cushion at contact points with glass

5

30

Lock

Hinged Door

95

Container of components

On/Off Switch

(accessible from top)

Viewing Direction

LED Lights Area exposed to view

Diffuser Panel

Approx. 6mm thick. Distribute light evenly below graphic print. Avoid hot spots or shadows from appearing

3

Plan View — Light Box Only

95

Scale 1:6 On/Off Switch

(accessible from top)

Light Box Cabinet

Light Box Cabinet Hidden from view

840

840

Graphic Print

Hinged Door

Printed on translucent substrate; Duratrans printing

Clear Optical Glass Panel

Movable for easy access for maintenance of interior components; heat vent perforated on door (illustration shown with door open)

LE

Approx. 6mm thick. Optically clear for graphic below to show clearly

No Ent

VE

L1

rt h

ran

ce

2

Folded Bezel

Part of the window of the cabinet works to hold glass panels in place; cushion at contact points with glass

Perforated heat vents pattern

1

Diffuser Panel

Yo

3

u Ar

e He

re

So Ent

en

riu

Ro

Lo

Q uic Se

Position Bracket

5

’s Re

str

Esca

G re

Ele

di to

Ele

m 1

va to

va to va to

om

un

cu

Po

Le k Re fer en rit y De ce sk

Le Le 12

Secure glass panels and graphic in firm position; cushion at contact points with glass

Inf r to

r to

diu

3- 45

ge ge ge

nd nd nd

To

we

r Inf

or

m at

e

H er

e

H er

e

6

Le Le Le

30

1

Front Interior View

2

Section View

4

Isometric View

95

Scale 1:6

95

Scale 1:6

95

Scale NTS

Le

ve

ls 00

r to

ve

Pa

ls Ele

curit

m

or

ve

ls 00

n

ls

-0 0 -0 0

rk ing

vato

y Ch

r

eck

5

12

Duratrans Print

va to

oo lat

atio

A Le

ve

4

ion

Clear Optical Glass Panel

Le

Se

H er

67

m

or m

CM

Le

r to

Ele

2

ge 3

Hidden from view

ce

M en

Ele

Au

VI P

Folded Bezel

uth

ran

3- 45

67

Te

lep

ho

ne

Di

ge ge ge

nd nd nd

re ct

or

H er

e

H er

e

H er

e

7 8 9

y

12

3- 45

67

LED Lights


74 CMA Tower Riyadh, Kingdom of Saudi Arabia

Acrylic Crystalline Component Sign Type FD

Acrylic Crystalline Component

220

135

40

220

50

The acrylic used shall be clear and without any hints of color cast or frosting. Diamond polish all surfaces for a clear, glossy finish allowing light to pass through. The color and graphic comes from the crystalline graphic film (see section on Crystalline Graphic Film) and is sandwiched in between two pieces of clear acrylic. Both acrylic pieces and graphic film to be cut precisely for an exact fit when fully assembled. Secure all three components tightly to ensure graphic film stays flat without bending. Use metal brackets to compress and fasten all pieces together. Install LED light source behind the acrylic for backlighting effect.

Crystalline Graphic Film Stainless steel structure

Acrylic B Diffuser backer (cut to shape)

Unexposed area of acrylic; secured within structure (shaded)

2

Front View

86

Scale 1:4

Unexposed area of acrylic; secured within structure (shaded)

Exposed area of acrylic (un-shaded)

Crystalline Graphic Film

Viewing Direction

Acrylic A (shaped and formed)

Acrylic B Diffuser backer

34

Compress and fasten pieces tightly

Acrylic A

Viewing Direction

1

Isometric View

3

Plan View

86

Scale NTS

86

Scale 1:4


75 CMA Tower Riyadh, Kingdom of Saudi Arabia

Acrylic Crystalline Component Sign Type FD Unexposed portion of acrylic (shaded)

Unexposed portion of acrylic (shaded)

Positioning Acrylic Crystalline within Sign Structure

Mirrored construction details

The majority of the acrylic is contained within the structure for protection and only a small portion is exposed for viewing (exposed portion shown in color). Use adequate lighting to backlight the exposed portion but the graphic film should cover the entirety of the acrylic, including the unexposed portion hidden from view.

Mirrored construction details eq.

2

Plan View

97

Scale 1:5

50

135

40

eq.

Acrylic A

Acrylic A

Crystalline Graphic Film

Crystalline Graphic Film

Acrylic B

Unexposed portion of acrylic (shaded)

Acrylic B

102°

Viewing Direction

Viewing Direction

Opening for Map LED light source

1

Front View

3

Side View of Acrylic Components

97

Scale 1:4

97

Scale 1:4


76 CMA Tower Riyadh, Kingdom of Saudi Arabia

Z Clips Details of Interlocking Clips for Side and Access Panels

Fasteners

Install flush; secures all components together; quantity TBD per sign type; consult construction engineer.

End Cap Panel

Tab extends underneath end cap

Side tab extends and aligns with frame

Support Frame

Welded

Fastener

Width of supporting frame Side tabs

Z Clip

(Component B) Mounts to side panel or access panels.

Z Clip

(Component B) Mounts to side panel or access panels.

Z Clip

(Component A) Mounts to support frame of sign structure.

Adjust width of Z Clips to fit mounting surface

End cap panel

Side tab Z Clip

(Component B) Mounts to side panel or access panels.

Access/detachable panel

Side panel

Z Clip

Detachable Panel

(Component A) Mounts to support frame of sign structure.

Support frame

Z Clip

(Component B)

Z Clip Welded

(Component A) Mounts to support frame of sign structure.

Z Clip

(Component A)

Support frame/ mounting surface

1

Rear Access Panel

2

Typical Z Clip Side View

3

Z Clip Isometric View

4

Section View

98

Scale NTS

98

Scale NTS

98

Scale NTS

98

Scale NTS


77 CMA Tower Riyadh, Kingdom of Saudi Arabia

Overhead Directional [OD] Measurements, Descriptions, and Construction Details Measurements in millimeters

Fabrication Notes & Requirements 1760

120

39

225

1

Plan View

FS

Scale 1:10

Suspension cable

112

112

2

119

FS

5

Actual seam created by legend plate

Crystalline Graphic See section on Crystalline Graphic Film. Allow ambient and natural lighting from environment to enter structure to illuminate the acrylic components.

175

300

Main Lobby

Auditorium

Structure should be symmetrical and structurally sound. Use additional structural reinforcement (internal and hidden from view) if necessary from an engineering standpoint. Edges are to be beveled and smoothed-out. Sign should be seamless with no visible fasteners except at plan view. If components are manufactured separately, the overall finish and color of material must be visually identical after assembly. Secure sign structure to ceiling using suspension cable. Production of a full-scale, working prototype is HIGHLY RECOMMENDED for this sign type to test for structural durability, functionality, and aesthetic quality.

Seam

2

Front View

FS

Scale 1:10

25

42

42

1760

120 225

3

Bottom View

4

Side View

FS

Scale 1:10

FS

Scale 1:5

If weight is an issue, it is optional to use aluminum as construction material; match finish to stainless steel. Adjust thickness of material to allow for welding without creasing and bending.


78 CMA Tower Riyadh, Kingdom of Saudi Arabia

Overhead Directional [OD] Material Identification Material Identification Refer to Material Identification Section

A

A

Ma

B

Structure Side and Bottom Stainless steel marine grade type 316 with satin, medium horizontal brush finish.

G G

C

Legend Type and Divider Line Legend and divider line to be cut out with gray vinyl matching PMS Cool Gray 11C and applied directly to surface of legend plate.

D Suspension Cable Stainless steel cable with a width of 5mm — 10mm with sufficient strength to safely suspend structure. Consult structural engineer for exact specifications. E

A

F

Au dit ori u

m

F

E C

100

Isometric for Material Identification Scale NTS

SS

MAT

SS

MAT

VY

MAT

SC

MAT

MAT

EG

Directional Arrow Acrylic to be cut and formed to shape of directional arrow (see section of directional arrow for details).

CA

MAT

DA

MAT

CA

MAT

CF

MAT

CA

For digital output, use art file: directional_arrow_art.ai

B

1

MAT

Faceted crystalline pattern to be etched and filled on stainless steel structure (see section of Faceted Crystalline Pattern for details).

D

in Lo bb y

Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish.

G

Crystalline Facet Acrylic to be cut and formed to shape of facet. All films are laminated together and sandwiched between acrylic blocks (see section of Crystalline Graphic Film for details). Light Roof Portion with clear acrylic to allow natural light to illuminate crystalline facet.


79 CMA Tower Riyadh, Kingdom of Saudi Arabia

Overhead Directional [OD] Exploded View Suspension Cable

Fastened securly to support frame

Cover Plate

Compresses the exterior elements to support frame Weld clip rail to exterior skin

Fasteners

Install to upper clip rail

Light Roof

Transparent resin adhered to central bridge. Allows natural and ambient light into the interior of sign structure

Central Bridge

Suspension Locking Plate

Keeps the support frame as one continuous piece

Connection point of suspension cable to support frame. Consult structural engineer for construction based on total weight of structure

Fasteners

Install to upper clip rail from top

Fasteners

Lower Clip Rail

Install to upper clip rail from top

Lower Clip Rail Metal Studs

Metal studs are welded to bottom plate and fastens to lower clip rail

Suspension Cable

Fastened securly to support frame

Horizontal Cross Beam

This is part of the support frame

Cover Plate

Compresses the exterior elements to support frame

Upper Clip Rail

This is part of the support frame

Spacer clip

Bottom Plate

Crystalline etched on to exposed surface of plate

Crystalline Facet Side Rail

Secures acrylic components (crystalline facet) in place. Weld upper and lower clip rail to this component. This section connects the two halves of the structure; allow for adequate structural reinforcement.

Horizontal Cross Beam

Exterior Skin

This portion welded to support frame

Upper Clip Rail

This is part of the support frame

Lower Clip Rail

This is part of the support frame

1 101

Isometric View of Interior Components Scale NTS

Bottom Plate

Etched crystalline pattern


80 CMA Tower Riyadh, Kingdom of Saudi Arabia

Overhead Directional [OD] Exploded View

Auditorium

Legend Plate

45

25 25

Cover Plate Compresses down the components securing the structure together

45

530

20 Clip rail

Ma

in Lo b

3 102

by

Surface of Legend Panel — Front View Scale 1:10

3

Upper clip rail 812

295

295

Viewing Direction

175

649

Legend Plate Apply legend here

Lower clip rail

1 102

Isometric View Scale NTS

2 102

Side View of Legend Panel Scale 1:5

4 102

Surface of Legend Panel — Rear View Scale 1:10


81 CMA Tower Riyadh, Kingdom of Saudi Arabia

Overhead Directional [OD] Section Views

Fasteners install through cover plate and structural frame

Clip

Shaped to form interlocking clip to structural frame; welded to legend plate

Cover Plate 120

Clip welded to legend plate interlocks with support frame

Cover Plate

Flush with fastener 3

26

5

103

Legend Plate

3mm thick

Structure Frame

Clip

Fastener

Structural Frame

Legend Plate

Interior open space

Shaped to form interlocking clip to structural frame; welded to legend plate

Interior open space Interior open space

Slightly angled and conform to overall shape of structure; 3mm thick

Structural Frame

Stud

Fastener

Bottom clip welded to legend plate interlocks with structural frame

Compresses cover plate and legend plates to frame and locks all components in place

4

103

Stud Bottom Panel

Structure Frame

No visible fasteners; secure to structural frame with stud

Legend Plate

3mm thick

Bottom Panel

No visible fasteners; secure to support frame with stud

1 103

Section View Scale 1:3

2 103

Section View Scale 1:3

3 103

Section View — Detail Scale 1:1

4 103

Section View — Detail Scale 1:1


82 CMA Tower Riyadh, Kingdom of Saudi Arabia

Overhead Directional [OD] Details of Acrylic Components Spacer Clips

22

Clips are fashioned to secure the acrylic components together and also act as spacers in betweeen the two groups

22

ACRYLIC GROUP 1 Acrylic A

Spacer Clip

Acrylic B

Slightly angled and conform to overall shape of structure; 3mm thick

Clips are fashioned to secure the two acrylic groups together

Cut to fit exactly behind acrylic A; 15mm thick

Exposed to view; 30mm thick

Crystalline Graphic Film

Acrylic B

Cut to fit exactly behind Acrylic A; 15mm thick

ACRYLIC GROUP 2 Acrylic B

Crystalline Graphic Film

Identical as opposite side; see above

Crystalline Graphic Film

Acrylic A 22

Identical as opposite side; see above

3 104

Plan View of Acrylic Groups with Fastening Clips Scale 1:10

112

22

Insert acrylic components here

25

300

20

Insert acrylic components here

25

42

112

Fastener from outward direction securing acrylic components; install through clip

Acrylic A

Exposed to view; 30mm thick

1 104

Acrylic Group Layering Isometric Scale NTS

Fastener Fastener from outward direction securing acrylic components; install through clip

(shaded portion is hidden from view)

2 104

Two Acrylic Groups with Clips Scale NTS

4 104

Front View of Exposed Surface of Acrylic Scale 1:10

5 104

Plan View of Spacer Clip Scale 1:2


83 CMA Tower Riyadh, Kingdom of Saudi Arabia

Area Marker [AM] Measurements, Descriptions, and Construction Details Measurements in millimeters

Fabrication Notes & Requirements Structure should be symmetrical and structurally sound. Use additional structural reinforcement (internal and hidden from view) if necessary from an engineering standpoint. Edges are to be beveled and smoothed-out. Sign should be seamless with no visible fasteners except at plan view. If components are manufactured separately, the overall finish and color of material must be visually identical after assembly. Secure sign structure to ceiling using suspension cable. Production of a full-scale, working prototype is HIGHLY RECOMMENDED for this sign type to test for structural durability, functionality, and aesthetic quality.

120mm

1070mm

Plan View Scale 1:10

2

Front View

105

Scale 1:10

3

Bottom View Scale 1:10

335mm

275mm

45

Crystalline Graphic See section on Crystalline Graphic Film. Allow ambient and natural lighting from environment to enter structure to illuminate the acrylic components.

80mm

85mm

105

Transfer to Level 00

45

25 25

210mm

330mm

5mm

1 105

120mm

450mm

4

Side View

105

Scale 1:10

If weight is an issue, it is optional to use aluminum as construction material; match finish to stainless steel. Adjust thickness of material to allow for welding without creasing and bending.


84 CMA Tower Riyadh, Kingdom of Saudi Arabia

Area Marker [AM] Material Identification

Material Identification Refer to Material Identification Section

A

B

A F F

A

D

C

C

E

Isometric for Material Identification Scale NTS

Legend Type Legend and divider line to be cut out with gray vinyl matching PMS Cool Gray 11C and applied directly to surface of legend plate.

D Suspension Cable Stainless steel cable with a width of 5mm — 10mm with sufficient strength to safely suspend structure. Consult structural engineer for exact specifications. E

1

Structure Side (Left And Right) Stainless steel marine grade type 316 with satin, medium horizontal brush finish.

MAT

SS

MAT

SS

MAT

VY

MAT

SC

MAT

CA

MAT

CA

MAT

EG

MAT

CF

Faceted crystalline pattern to be etched and filled on stainless steel structure (see section of Faceted Crystalline Pattern for details).

B

106

Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish.

F

Crystalline Facet Acrylic to be cut and formed to shape of facet. All films are laminated together and sandwiched between acrylic blocks (see section of Crystalline Graphic Film for details). Light Roof Portion with clear acrylic to allow natural light to illuminate crystalline facet.


85 CMA Tower Riyadh, Kingdom of Saudi Arabia

Area Marker [AM] Exploded View

Cover plate

Upper clip rail

50mm Legend plate

275mm

210mm

Clip rail

900mm

2 108

Lower clip rail

Surface of Legend Panel — Rear View Scale 1:10

275

3

Legend plate

1 108

Isometric View Scale NTS

3 108

Side View of Legend Panel Scale 1:5

Viewing Direction


86 CMA Tower Riyadh, Kingdom of Saudi Arabia

Room Announcer [RA] Material Identification Material Identification Refer to Material Identification Section

A

B

Structure Side (Top, Side and Bottom) Stainless steel marine grade type 316 with satin, medium horizontal brush finish.

MAT

SS

MAT

SS

MAT

EG

MAT

EG

MAT

CA

MAT

EG

MAT

CF

Faceted Crystalline pattern to be etched and filled on stainless steel structure (see section of Etched Type and Graphics for details).

E

C

B

Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish.

A

A

Legend Type and Divider Line Legend and divider line to be etched and filled with gray matching PMS Cool Gray 11C on stainless surface (see section of Etched Type and Graphics for details).

D D Etched Graphic Line graphic to be etched and filled with gray matching PMS Cool Gray 11C on stainless surface (see section of Etched Type and Graphics for details).

B

E

C

1 112

Isometric for Material Identification Scale NTS

Crystalline Facet Acrylic to be cut and formed to shape of facet. All films are laminated together and sandwiched between acrylic blocks (see section of Crystalline Graphic Film for details).


87 CMA Tower Riyadh, Kingdom of Saudi Arabia

Room Announcer [RA] Measurements, Descriptions, and Construction Details

50mm

5mm

Unexposed portion of acrylic (shaded)

3

Detail of Plan View

113

Scale 1:2

Isometric View Scale NTS

160mm

25mm

4

100mm

90mm

113

Unexposed portion of acrylic (shaded)

280mm

2 113

Left Side View Scale 1:8

100mm

4 113

Detail of Left Side View Scale 1:3

148mm

1 113


88 CMA Tower Riyadh, Kingdom of Saudi Arabia

Perpendicular Announcer [PA] Material Identification Material Identification Refer to Material Identification Section

A A

B

A

C

B

C

D

1

Front View

115

Scale NTS

Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish. Pictogram Pictogram to be etched and filled with gray matching PMS Cool Gray 11C on stainless surface (see section of Etched Type and Graphics for details). Legend Type and Divider Legend and divider to be etched and filled with gray matching PMS Cool Gray 11C on stainless surface (see section of Etched Type and Graphics for details).

D Crystalline Facet Acrylic to be cast to shape of facet. All films are laminated together and sandwiched between acrylic blocks (see section of Crystalline Graphic Film for details).

MAT

SS

MAT

EG

MAT

EG

MAT

CA

MAT

CF


89 CMA Tower Riyadh, Kingdom of Saudi Arabia

Perpendicular Announcer [PA] Construction Details

Stainless steel

Stainless steel

Graphic film mounted to the front to stainless steel panel

Clear acrylic

Stainless steel Acrylic Group A Corner acrylic Graphic film mounted to the back of clear acrylic

Back plate

Acrylic Group A

Graphic film Corner acrylic Stainless steel (surface for etching) Clear acrylic (cast piece)

Stainless steel (surface for etching)

Acrylic Group B

Acrylic Group B Clear acrylic (cast piece)

1 116

Isometric View Scale NTS

2 116

Isometric Exploded View Scale NTS

Graphic film (folded to conform to shape of acrylic)

Stainless steel (surface for etching)

Clear acrylic (cast piece)

3 116

Isometric of Individual Components Scale NTS

4

Back Plate

116

Scale NTS


90 CMA Tower Riyadh, Kingdom of Saudi Arabia

Small Perpendicular Announcer [PS] Measurements, Descriptions, and Construction Details

125mm

12

115mm

5mm

200mm

3 117

Flat Elevation (Top) Scale 1:3

5mm

85mm

100mm

C2

Height of elevator door

100mm

50mm

200mm

50mm

175mm

100mm

100mm

125mm

125mm

1 117

Small Perpendicular Announcer Scale 1:3

2 117

Right Side View Scale 1:3

4 117

Flat Elevation (Bottom) Scale 1:3

5 117

Typical Elevation Scale 1:25


91 CMA Tower Riyadh, Kingdom of Saudi Arabia

Wall Mounted Directional [WD] Material Identification Material Identification Refer to Material Identification Section

A

B

A B

Info Info Info Info Info

r ma

r ma

r ma r ma r ma

C

C

Info

t io n t io n t io n

Info

D

Info

E

r ma r ma r ma

t io n t io n t io n

Info

r ma

Info t io n

r ma

t io n

E

Front View Scale 1:10

SS

MAT

TA

MAT

EG

MAT

CA

MAT

MA

MAT

CA

MAT

DA

Magnetic Block Magnetic block to be embedded into the clear acrylic and to be concealed from view.

MAT

CF

F E

1

Legend Type and Divider Line Legend and divider line to be etched and filled with gray matching PMS Cool Gray 11C on stainless surface (see section of Etched Type and Graphics for details).

MAT

For digital output, use art file: directional_arrow.ai

F

121

Header and Divider Line R-Cast. Gray matching PMS Cool Gray 11C. Fabricated dimensional letters applied on stainless steel surface.

D Directional Arrow Acrylic to be cut and formed to shape of directional arrow (see section of directional arrow for details).

t io n

t io n

Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish.

F

Crystalline Facet Acrylic to be cut and formed to shape of facet. All films are laminated together and sandwiched between acrylic block and opaque white backing (see section of Crystalline Graphic Film for details).


92 CMA Tower Riyadh, Kingdom of Saudi Arabia

Wall Mounted Directional [WD] Construction Details

1mm 3mm 10mm

Stainless steel Stainless steel Acrylic Dimensional letters

Header with reveal cut

Graphic film

Graphic film

Dimensional letters

Clear acrylic

Viewing Direction

3

Viewing Direction

122

Info Info Info

Info

r ma

t io n Info rm

Legend plate

1 122

Isometric View Scale NTS

a t io

n

Magnet

r ma r ma

t io n t io n

Acrylic Graphic film

Magnet Legend plate

r ma

t io n

Clear acrylic dimensional arrow

Magnet

Legend plate

Graphic film (adhere to the back of acrylic arrow)

2 122

Right Side View Scale 1:10

3 122

Header Side View Scale 1:2

4 122

Header Layering — Side View Scale 1:2


93 CMA Tower Riyadh, Kingdom of Saudi Arabia

Sign Codes Signage Related Code Compliance

CMA Tower and Capital Market Authority sign system will be complying with the International Building Code (IBC), National Fire Protection Association [NFPA], and American National Standards Institute [ANSI] for all architectural and building issues. Included are signage related code compliance.

IBC — 2009

NFPA 101 — 2009

ANSI 117.1 — 2003

General Building Codes

Fire and Life Safety

Accessibility

Stairs Stair Identification

Stairs Tactile Exit Signs Stair Identification and Landing Information Tactile Level Identification

Communications Visual Character Heights (Directional Signs)

Two-way Communication Systems (instructions regarding the use) Elevators Pictorial Life Safety Signs Self-Evacuation Signs Lobby Status Indicators Ambulance Stretcher Accommodations (Star of Life) Means of Egress Exit Signs (illuminated and tactile) Accessible Routes Areas of Refuge Maximum Occupancy Signs

Exits Tactile Exit Signs Powered Door Signs Egress Egress Identification NO Exit Signs

Room and Space Identification Sign Mounting Heights and Locations Tactile Characters Braille Pictogram Signs International Symbol of Accessibility Elevators Signals (Visible and Audible) Floor Designations (door jambs) Operational Status Evacuation Diagrams (maps) Protruding Objects Parking Spaces


94 CMA Tower Riyadh, Kingdom of Saudi Arabia

All Code Regulated Signs Tactile and Braille

ANSI 117.1 - 2003

ANSI 117.1 — 2003

Tactile Characters

Braille

Depth: Must be raised 1/32 inch (0.8 mm) minimum. Case: All uppercase. The indication of an uppercase letter or letters shall only be used before the first word of sentences, proper nouns and names, individual letters of the alphabet, initials, or acronyms. Style: San serif (no italic, oblique, script or decorative). Height: 5/8 inch (16 mm) height minimum. 2 inch (51 mm) height maximum. Use uppercase “I” to determine character height. Exception: Can be 1/2 inch (13mm) if tactile and visual characters provide the same information. Width: Chracters shall be 55% minimum and 110% maximum width of the uppercase character height. Use uppercase “O” to determine character width. Maximum: 15% of uppercase “I”. Minimum: 10% of uppercase “I”.

Character Spacing: Character spacing shall be measured between the two closest points of adjacent tactile characters within a message, excluding word spaces. Spacing between individual tactile characters shall be 1 /8 inch (3.2 mm) minimum measured at the top surface of the characters, 1 /16 inch (1.6 mm) minimum measured at the base of the characters, and four times the tactile character stroke width maximum. Characters shall be separated from raised borders and decorative elements 3 /8 inch (9.5 mm) minimum.

Type: Braille shall be contracted (Grade 2) Braille. Dimensions: Braille dots shall have a domed or rounded shape and shall comply with Table 703.4.3 (below). Braille Position: Braille shall be below the corresponding text. If text is multilined, Braille shall be placed below entire text. Braille shall be separated 3 /8 inch (9.5 mm) minimum from any other tactile characters and 3 /8 inch (9.5 mm) minimum from raised borders and decorative elements. Braille provided on elevator car controls shall be separated 3 /16 inch (4.8 mm) minimum either directly below or adjacent to the corresponding raised characters or symbols.

Line Spacing: Spacing between the baselines of separate lines of tactile characters within a message shall be 135% minimum and 170% maximum of the tactile character height. Finish and Contrast: Characters and their background shall have a nonglare finish. Characters shall contrast with their background, with either light characters on a dark background, or dark characters on a light background.

Distance between dots in the same cell

Distance between dots in adjacent cell Single Braille cell

Distance between dots in the same cell

Distance between corresponding dots from one cell directly below

Blank cell space between words Raised dot

9.5mm

Dot diameter No raised dot 9.5mm

Table 703.4.3


95 CMA Tower Riyadh, Kingdom of Saudi Arabia

Room Number [RN] Measurements, Descriptions, and Construction Details

Crystalline Graphic Film The iridescent, translucent, and vibrant qualities of the crystalline graphics are achieved through the layering of serveral different materials—each with its unique visual quality—and laminated as a single surface placed behind the clear acrylic block.

1mm metal backing painted white on all sides

SOLYX (sxlt-1302) Clear Icicles SOLYX Bahama Print on HDTE clear film

Acrylic block

Stainless steel with satin finish Cut out on stainless steel face Polished clear acrylic Braille

1 126

Layering Composition Scale NTS


96 CMA Tower Riyadh, Kingdom of Saudi Arabia

Room Number and Room Identification [RN][RI] Material Identification Material Identification Refer to Material Identification Section

A A D B

B

C D G

1

3

CMA Room Number Sign - Isometric for Material Identification

128

C

128

Scale NTS

CMA Tower Room Number Sign - Isometric for Material Identification

Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish. Room Number Clear acrylic. Fabricated dimensional letters push-through stainless steel surface.

MAT

SS

MAT

CA

MAT

EG

MAT

MA

MAT

EG

MAT

CA

Braille Braille must be Grade 2 with domed or rounded shape (see Tactile and Braille section).

Scale NTS D Etched Graphic Line graphic to be etched and filled with gray matching PMS Cool Gray 11C on stainless surface (see section of Etched Type and Graphics for details).

A E

D B

Magnetic Block Magnetic block to be embedded into the clear acrylic and to be concealed from view.

C F

D E

Legend Type and Divider Line Legend and line to be etched and filled with gray matching PMS Cool Gray 11C on stainless surface (see section of Etched Type and Graphics for details).

F

2 128

CMA Room Identification Sign - Isometric for Material Identification Scale NTS

4 128

CMA Tower Room Identification Sign - Isometric for Material Identification Scale NTS

G Crystalline Facet Acrylic to be cut and formed to shape of facet. All films are laminated together and sandwiched between acrylic block and opaque white backing (see section of Crystalline Graphic Film for details).

MAT

CF


97 CMA Tower Riyadh, Kingdom of Saudi Arabia

Room Identification [RI] Measurements, Descriptions, and Construction Details

Detailed Material and Dimension Callouts

Fabricated room numbers adhere to surface. Use the same translucent material as the core of sign

Additional information on material usage and dimensions for final fabrication process.

200mm

1mm

90mm

20mm High quality graphic output of pattern and color on foil (metallic sheen) paper

5mm

16mm

Optically clear, transparent acrylic with diamond polished edges

70mm

75mm

25mm

2mm

4mm

2mm

Viewing Direction Routed to fit magnet stripes

Large Conference Room Stainless steel veneer with satin finish

1 129

Room Identification Sign Front View Scale 3:4

Legend to be etched and filled on stainless surface; 9mm at Alif and X height

Magnet B: Adhere to legend plate Legend plate

9mm

40mm

9mm

Magnet A: Adhere to sign

Etched line graphic

2

Side View

129

Scale 3:4


98 CMA Tower Riyadh, Kingdom of Saudi Arabia

Room Identification [RI] Measurements, Descriptions, and Construction Details

Detailed Material and Dimension Callouts

Fabricated room numbers adhere to surface. Use the same translucent material as the core of sign

Additional information on material usage and dimensions for final fabrication process.

200mm 1mm

140mm

20mm 16mm

8mm

56mm

High quality graphic output of pattern and color on foil (metallic sheen) paper

42mm

2mm

75mm

Optically clear, transparent acrylic with diamond polished edges

4mm

2mm

Viewing Direction Routed to fit magnet stripes Magnet A: Adhere to sign

40mm

Magnet B: Adhere to legend plate

Large Conference Room Stainless steel veneer with satin finish

1 130

Room Identification Sign Front View Scale 3:4

Legend plate

Legend to be etched and filled on stainless surface

Etched line graphic

2

Side View

130

Scale 3:4


99 CMA Tower Riyadh, Kingdom of Saudi Arabia

Support Room Identification [SI] Measurements, Descriptions, and Construction Details

Fabricated room numbers 2mm thick acrylic, painted black, and adhered to metal surface

165mm 13mm

1 132

Scale 3:4

Braille

Graphic output or back painted Tactile Braille Viewing Direction

9mm

10mm 19mm

Room Identification Sign Front View (Typical)

Legend to be etched and filled on stainless surface

1mm stainless steel plate

6mm clear acrylic

8mm

Stainless steel veneer with satin finish

9mm 7mm

9mm

2mm 20mm

40mm

Large Conference Room

2mm

4mm

64mm

18mm

All legends and Braille to be flushed left

2

Side View

132

Scale 3:4

3mm opening


100 CMA Tower Riyadh, Kingdom of Saudi Arabia

Support Room Number and Support Room Identification [SN][SI] Material Identification Material Identification Refer to Material Identification Section

A

B

C

E

B C D

F E

F

1

CMA Support Room Number Sign - Isometric for Material Identification Scale NTS

MAT

SS

MAT

TA

MAT

MA

Legend Type and Divider Line Legend and divider line to be cut out with gray vinyl matching PMS Cool Gray 11C and applied directly to surface of Legend Plate.

MAT

VY

Crystalline Facet All films are laminated together and sandwiched between acrylic block and opaque white backing (see section of Crystalline Graphic Film for details).

MAT

CA

Room Number R-Cast. Gray matching PMS Cool Gray 11C. Fabricated dimensional letters applied on stainless steel surface. Braille Braille must be Grade 2 with domed or rounded shape (see Tactile and Braille section).

D Magnetic Block Magnetic block to be embedded into the clear acrylic and to be concealed from view.

A

133

Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish.

2 133

CMA Tower Support Room Identification Sign - Isometric Scale NTS

MAT

CF


101 CMA Tower Riyadh, Kingdom of Saudi Arabia

Installation Detail Room Number and Room Identification Sign

Note: The preferred method of installation is OPTION A. Choice of installation method based on sign location’s circumstances and should be attempted in the order of A,B,C and D until sign is successfully installed. Use below installation method for various wall mounted signs.

PREFERRED METHOD

1 135

Install sign on strike side of door. Allow 75mm from edge of door frame and 1500mm from top of sign to finished floor.

Preferred Installation — Option A Scale 1:30

Install sign on strike side of door. Allow 75mm from obstruction to right edge of sign but no more than 460mm from edge of door frame. 1500mm from top of sign to finished floor.

2 135

Installation — Option B Scale 1:30

75mm

75mm

75mm

75mm

75mm

75mm

75mm

Install sign on opposite to strike side of door. Allow 75mm from door frame or obstruction to left edge of sign but no more than 460mm from edge of door frame. 1500mm from top edge of sign to finished floor.

3 135

Installation — Option C Scale 1:30

Install sign directly on door if both sides are obstructed. Center sign on door and 1500mm from top edge of sign to finished floor.

4 135

Installation — Option D Scale 1:30


102 CMA Tower Riyadh, Kingdom of Saudi Arabia

Pictogram Sign [PT] Measurements, Descriptions, and Construction Details

160mm

ANSI 117.1 - 2003 Tactile Characters

20mm

Refer to specifications on Tactile and Braille page.

Braille Refer to specifications on Tactile and Braille page.

160mm

1 136

15mm

3

CMA Pictogram Sign

136

Scale 1:3

CMA Tower Pictogram Sign Scale 1:3

15mm

Pictogram Field Pictograms shall have a field 6 inches (150 mm) minimum in height. Characters or Braille shall not be located in the pictogram field.

Finish and Contrast Pictograms and their fields shall have a nonglare finish. Pictograms shall contrast with their fields, with either a

150 mm (6� minimum)

light pictogram on a dark field or a dark pictogram on a light field.

150 mm (6� minimum)

Text Descriptors 270mm

Where text descriptors for pictograms are required, they shall be located directly below the pictogram field. 10 mm

Finish and Contrast

16mm

Symbols of accessibility and their backgrounds shall have

12mm

a nonglare finish. Symbols of accessibility shall contrast

16mm

with their backgrounds, with either a light symbol on a

10mm

dark background or a dark symbol on a light background.

10 mm

MEN

16mm 12mm 16mm 10 mm

MEN

15mm

2 136

CMA Pictogram Sign Scale 1:3

4 136

CMA Tower Pictogram Sign Scale 1:3

15mm


103 CMA Tower Riyadh, Kingdom of Saudi Arabia

Pictogram Sign [PT] Material Identification Material Identification Refer to Material Identification Section

A

B

A F C

B

Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish. Pictogram R-Cast. Gray matching PMS Cool Gray 11C. Fabricated dimensional letters applied on stainless steel surface. Legend Type R-Cast. Gray matching PMS Cool Gray 11C. Fabricated dimensional letters applied on stainless steel surface.

D Divider Line Divider line to be etched and filled with gray matching PMS Cool Gray 11C on stainless surface (see section of Etched Type and Graphics for details).

E

Braille Braille must be Grade 2 with domed or rounded shape (see Tactile and Braille section).

F

Crystalline Facet Acrylic to be cut and formed to shape of facet. All films are laminated together and sandwiched between acrylic block and opaque white backing (see section of Crystalline Graphic Film for details).

C

D

E

F

1 137

CMA Pictogram Sign - Isometric for Material Identification Scale NTS

2 137

CMA Tower Pictogram Sign - Isometric for Material Identification Scale NTS

MAT

SS

MAT

TA

MAT

TA

MAT

EG

MAT

CA

MAT

CF


104 CMA Tower Riyadh, Kingdom of Saudi Arabia

Elevator/Lift Landing and Service Elevator [EE][SE] Measurements, Descriptions, and Construction Details

IBC — 2009

letter height of in. (16 mm) posted in every elevator lobby: (1)* Signs that indicate that the elevator can be used for

1

3

CMA Elevator/Lift Landing Sign Plan View

138

138

Scale 1:5

6mm

1mm

7.2.13.1) shall have the following signs with a minimum

20mm

Elevators that are a part of a means of egress (see

15mm

290mm

7.10.8.4 Elevator Signs

5

CMA Elevator/Lift Landing Sign Bottom View

Service Elevator/Lift Landing Sign Plan View

138

Scale 1:5

Scale 1:5

egress, including any restrictions on use;

112mm

(2)* Signs that indicate the operational status of elevators.

185mm

Tower Security

123- 4567

Fire Depar tment

2

2

CMA Elevator/Lift Landing Sign Front View Scale 1:8

Legend Key Elevator

Legend Key Elevator Stair way

Stair way E xit Route E xit Route

4 138

123- 4567

Tower Security

123- 4567

Fire Depar tment

You Are Here

CMA Tower Elevator/Lift Landing Sign Front View Scale 1:8

526mm

Evacuation Plan

You Are Here

FS

138

Evacuation Plan

10mm

123- 4567

30

LE VEL

LE VEL

You Are Here

20mm

112mm

30

Legend Key Elevator Stair way

E xit Route

6 138

123- 4567

Tower Security

123- 4567

Fire Depar tment

10mm

185mm

Evacuation Plan

IN FIRE EMERGENCY, DO NOT USE ELEVATOR. USE EXIT STAIRS.

2mm

30

LE VEL

IN FIRE EMERGENCY, DO NOT USE ELEVATOR. USE EXIT STAIRS.

185mm

IN FIRE EMERGENCY, DO NOT USE ELEVATOR. USE EXIT STAIRS.

585mm

acceptable to the authority having jurisdiction.

85mm

112mm

shall be posted and oriented in a location and manner

112mm

reflecting the actual floor arrangement and exit locations

585mm

Chapters 11 through 43, floor evacuation diagrams

85mm

85mm

Where a posted floor evacuation map is required in

1

FS

112mm

7.10.8.5* Evacuation Map

Service Elevator/Lift Landing Sign Front View Scale 1:8


105 CMA Tower Riyadh, Kingdom of Saudi Arabia

Elevator/Lift Landing and Service Elevator [EE][SE] Measurements, Descriptions, and Construction Details

Digital print mounted to the back of clear acrylic

Acrylic and map insert slides in

Routed to fit in slider

Routed to receive acrylic panel Routed insert slot in acrylic

Refer to section in Mapping Graphics for additional information on maps

1 141

Isometric View Scale NTS

2 141

Isometric View Scale NTS

3 141

Isometric View Scale NTS


106 CMA Tower Riyadh, Kingdom of Saudi Arabia

Evacuation Map [EM] Measurements, Descriptions, and Construction Details

300mm 260mm

Four-color silkscreen map graphic

1

Plan View

142

Scale 1:4

20mm 150mm radius hexagon 130mm radius hexagon

Stainless steel Magnet adheres to plate Clear acrylic

Graphic output

130mm

2 142

150mm Front View Scale 1:4

3 142

Right Side View Scale 1:4

4

Isometric

142

Scale NTS


107 CMA Tower Riyadh, Kingdom of Saudi Arabia

Stair Door Identification [ST] Measurements, Descriptions, and Construction Details

160mm

160mm

ANSI 117.1 — 2003 Pictogram Field

Same as for pictogram signs if pictograms are used.

Tactile Characters Refer to specifications on Tactile and Braille page.

20mm

1 144

20mm

IBC — 2009 1011.3 Tactile Exit Signs

A tactile sign stating EXIT and complying with ICC A117.1 shall be provided adjacent to each door to an area of refuge, an exterior area for assisted rescue, an exit stairway, an exit ramp, an exit passageway and the exit discharge.

NFPA 101 — 2009

144

Scale 1:4

CMA Tower Stair Door ID Sign Plan View Scale 1:4

15mm

Braille Refer to specifications on Tactile and Braille page.

3

CMA Stair Door ID Sign Plan View

15mm 16mm

12mm 16mm 10mm

STAIR A

10mm

STAIR A

16mm 10mm

STAIR A

10mm EXIT

150mm 370mm

7.10.1.3 Exit Door Tactile Signage

Tactile signage shall be provided to meet the following criteria, unless otherwise provided in 7.10.1.4: (1) Tactile signage shall be located at each exit door requiring an exit sign. (2) Tactile signage shall read as follows: EXIT. (3) Tactile signage shall comply with ICC/ANSI A117.1, American National Standard for Accessible and Usable Buildings and Facilities.

16mm 12mm

150mm

10mm 16mm 12mm 16mm 10mm

455mm

EXIT

10mm

EXIT

7.2.2.5.4 Stairway Identification

16mm 12mm 16mm

See ANSI 117.1 installation requirements

10mm 15mm

Stair identification needs to be letters not numbers. These signs to be located on the occupancy or entrance side of the stairwell.

15mm

2 144

CMA Stair Door ID Sign Front View Scale 1:4

4 144

CMA Tower Stair Door ID Sign Front View Scale 1:4

5 144

Typical Elevation Scale 1:25


108 CMA Tower Riyadh, Kingdom of Saudi Arabia

Stairway Identification [SW] Measurements, Descriptions, and Construction Details

7.2.2.5.4* Stairway Identification

7.2.2.5.4.1 New enclosed stairs serving three or more stories and existing enclosed stairs serving five or more stories shall comply with 7.2.2.5.4.1(A) through (M). (A) The stairs shall be provided with special signage within the enclosure at each floor landing. (B) The signage shall indicate the floor level. (C) The signage shall indicate the terminus of the top and bottom of the stair enclosure. (D) The signage shall indicate the identification of the stair enclosure. (E) The signage shall indicate the floor level of, and the direction to, exit discharge. (F) The signage shall be located inside the enclosure approximately 60 in. (1525 mm) above the floor landing in a position that is visible when the door is in the open or closed position. (G) The signage shall comply with 7.10.8.1 and 7.10.8.2 of this Code. (H) The floor level designation shall also be tactile in accordance with ICC/ANSI A117.1, American National Standard for Accessible and Usable Buildings and Facilities. (I) The signage shall be painted or stenciled on the wall or on a separate sign securely attached to the wall. (J) The stairway identification letter shall be located at the top of the sign in minimum 1 in. (25 mm) high lettering and shall be in accordance with 7.10.8.2.

370

(K)* Signage that reads NO ROOF ACCESS and is located under the stairway identification letter shall designate stairways that do not provide roof access. Lettering shall be a minimum of 1 in. (25 mm) high and shall be in accordance with 7.10.8.2. (L) The floor level number shall be located in the middle of the sign in minimum 5 in. (125 mm) high numbers and shall be in accordance with 7.10.8.2. Mezzanine levels shall have the letter “M” or other appropriate identification letter preceding the floor number, while basement levels shall have the letter “B” or other appropriate identification letter preceding the floor level number. (M) Identification of the lower and upper terminus of the stairway shall be located at the bottom of the sign in minimum 1 in. (25 mm) high letters or numbers and shall be in accordance with 7.10.8.2. 7.2.2.5.4.2 Wherever an enclosed stair requires travel in an upward direction to reach the level of exit discharge, special signs with directional indicators showing the direction to the level of exit discharge shall be provided at each floor level landing from which upward direction of travel is required, unless otherwise provided in 7.2.2.5.4.2

25

FLOOR

30

1mm stainless steel plate

25 6mm clear acrylic

30 Graphic output or back painted

125

30 25

3

3mm opening

25

B1 TO 65th FLOOR

20 25 25 25

NO ROOF ACCESS

(A) and 7.2.2.5.4.2(B), and the following also shall apply: (1) Such signage shall comply with 7.10.8.1 and 7.10.8.2. (2) Such signage shall be visible when the door leaf is in the open or closed position. (A) The requirement of 7.2.2.5.4.2 shall not apply where signs required by 7.2.2.5.4.1 are provided. (B) The requirement of 7.2.2.5.4.2 shall not apply to stairs extending not more than one story below the level of exit discharge where the exit discharge is clearly obvious.

30

STAIR A

62

630

NFPA 101 — 2009

DOWN TO 1ST FLOOR FOR EXIT DISCHARGE

20 25 15 15 15 18 15 15

8

8

30

1 146

CMA Tower Stairwell Identification at Landings Scale 1:5

2

Side View

146

Scale 1:5


109 CMA Tower Riyadh, Kingdom of Saudi Arabia

Stairway Level Sign [SL] Measurements, Descriptions, and Construction Details

ANSI 117.1 — 2003 Tactile Characters Refer to specifications on Tactile and Braille page.

Braille Refer to specifications on Tactile and Braille page.

IBC — 2009

Need specific code references.

NFPA 101 — 2009

1 mm

90mm

7.2.2.5.4 Stairway Identification

110mm

15mm

(H) The floor level designation shall also be tactile in accordance with ICC/ANSI A117.1, American National Standard for Accessible and Usable Buildings and Facilities.

53 90mm

50mm

10mm 10mm 455mm

LIFT CS1-CS3

See ANSI 117.1 installation requirements

STAIR C

1 Proposed Typical Sign Location

148

Typical Sign Layout Scale 1:2

2 148

Side View

3

Scale 1:2

148

Egress Level Layout Scale 1:2

4 148

Typical Elevation Scale 1:25


110 CMA Tower Riyadh, Kingdom of Saudi Arabia

No Exit Sign [NE] Measurements, Descriptions, and Construction Details

95 mm

NFPA - 2009 7.10.8.3* No Exit 7.10.8.3.1

Center pictogram within field

115 mm

Any door, passage, or stairway that is neither an exit nor a way of exit access and that is located or arranged so that it is likely to be mistaken for an exit shall be identified by a sign that reads as follows:

NO

140 mm

EXIT

7.10.8.3.2 The NO EXIT sign shall have the word NO in letters 2 in. 115 mm

(~50 mm) high, with a stroke width of 3/8 in. (9.5 mm), and the word EXIT in letters 1 in. (25 mm) high, with the word EXIT below the word NO, unless such sign is an

Size of Arabic message adjustable

12mm

NO EXIT

15mm

50mm

12mm

131 mm

115 mm

approved existing sign.

25mm 15mm

NO EXIT

10mm 15mm

12mm

12mm 12mm

1 150

No Exit Sign Sample Layout Scale 1:3

2 150

No Exit Sign Sample Layout Scale 1:3

3

Side View

150

Scale 1:3


111 CMA Tower Riyadh, Kingdom of Saudi Arabia

Exit Door Sign [ED] Measurements, Descriptions, and Construction Details 150 mm field required for pictograms if they are utilized (typical exit symbol) Pictograms not required

115mm

IBC — 2009

6mm

1011.3 Tactile Exit Signs

A tactile sign stating EXIT and complying with ICC A117.1 shall be provided adjacent to each door to an area of refuge, an exterior area for assisted rescue, an exit stairway, an exit ramp, an exit passageway and the exit discharge.

1mm stainless steel plate

30mm

Clear acrylic

NFPA 101 — 2009 7.10.1.3 Exit Door Tactile Signage

Tactile signage shall be provided to meet the following criteria, unless otherwise provided in 7.10.1.4: (1) Tactile signage shall be located at each exit door requiring an exit sign. (2) Tactile signage shall read as follows: EXIT. (3) Tactile signage shall comply with ICC/ANSI A117.1, American National Standard for Accessible and Usable Buildings and Facilities.

150mm

See ANSI 117.1 installation requirements 238mm 30mm EXIT

7.2.2.5.5.8 Emergency Exit Symbol

16mm

12mm 16mm

10mm

15mm

Pictogram Field: Same as for pictogram signs if

15mm

pictograms are used.

Braille: Refer to specifications on Tactile and Braille page.

EXIT 455mm

ANSI 117.1 — 2003 Tactile Characters: Refer to specifications on Tactile

Open to acrylic

3mm 10mm

An emergency exit symbol with a luminescent background shall be applied on all doors serving the exit enclosure that swing out from the enclosure in the direction of egress travel. The emergency exit symbol shall also meet the following requirements: (1) The emergency exit symbol shall meet the requirements of NFPA 170, Standard for Fire Safety and Emergency Symbols. (2) The emergency exit symbol applied on the door shall be no higher than 18 in. (455 mm) above the finished floor.

and Braille page.

Graphic output or back painted

1 152

Front View Scale 1:2

2

Side View

152

3

Scale 1:2

152

Typical Elevation Scale 1:25


112 CMA Tower Riyadh, Kingdom of Saudi Arabia

Area of Refuge [AR] Measurements, Descriptions, and Construction Details

Metal

1. Each door providing access to an area of refuge from an adjacent floor area shall be identified by a sign stating: AREA OF REFUGE. 2. Each door providing access to an exterior area for assisted rescue shall be identified by a sign stating: EXTERIOR AREA FOR ASSISTED RESCUE. Signage shall comply with the ICC A117.1 requirements for visual characters and include the International Symbol of Accessibility. Where exit sign illumination is required by Section 1011.2, the signs shall be illuminated. Additionally, tactile signage complying with ICC A117.1 shall be located at each door to an area of refuge and exterior area for assisted rescue in accordance with Section 1011.3.

1007.10 Directional Signage

Directional signage indicating the location of the other means of egress and which are accessible means of egress shall be provided at the following:

6mm

15 mm

15 mm

1mm stainless steel plate

16 mm

1. Persons able to use the exit stairway do so as soon as possible, unless they are assisting others.

12 mm 16 mm

2. Information on planned availability of assistance in the use of stairs or supervised operation of elevators and how to summon such assistance.

10 mm

AREA OF REFUGE

Clear acrylic

10 mm

3mm opening

3. Directions for use of the two-way communications system where provided.

1011.2 Illumination

Exit signs shall be internally or externally illuminated. Exception: Tactile signs required by Section 1011.3 need not be provided with illumination.

326mm

Signage indicating special accessibility provisions shall be provided as shown:

210mm

In areas of refuge and exterior areas for assisted rescue, instructions on the use of the area under emergency conditions shall be posted. The instructions shall include all of the following:

85mm

1007.9 Signage

1007.11 Instructions

150 mm (6� minimum)

1011.3 Tactile Exit Signs

Graphic output or back painted

A tactile sign stating EXIT and complying with ICC A117.1 shall be provided adjacent to each door to an area of refuge, an exterior area for assisted rescue, an exit stairway, an exit ramp, an exit passageway and the exit discharge.

3mm opening

10 mm 16 mm

1. At exits serving a required accessible space but not providing an approved accessible means of egress.

12 mm

2. At elevator landings.

10 mm

3. Within areas of refuge.

15 mm

16 mm

International Symbol of Accessibility

1 154

Front View Scale 3:8

EXIT

85mm

IBC - 2009

150mm field required for pictograms (potential A of R symbol)

2

Side View

154

Scale 3:8


113 CMA Tower Riyadh, Kingdom of Saudi Arabia

Two-Way Communication Sign [TW] Measurements, Descriptions, and Construction Details

IBC — 2009

Metal

240mm

English message TBD

1007.6.3 Two-Way Communication

Areas of refuge shall be provided with a two-way communication system complying with Sections 1007.8.1 and 1007.8.2.

1007.8 Two-Way Communication

A two-way communication system shall be provided at the elevator landing on each accessible floor that is one or more stories above or below the story of exit discharge complying with Sections 1007.8.1 and 1007.8.2.

150mm

In the event of emergency, this phone will provide direct contact to security and emergency personnel.

Exceptions:

1. Two-way communication systems are not required at the elevator landing where the two-way communication system is provided within areas of refuge in accordance with Section 1007.6.3. 2. Two-way communication systems are not required on floors provided with exit ramps conforming to the provisions of Section 1010.

In the event of emergency, this phone will provide direct contact to security and emergency personnel.

EMERGENCY PHONE

3mm

1007.8.1 System Requirements

Two-way communication systems shall provide communication between each required location and the fire command center or a central control point location approved by the fire department. Where the central control point is not constantly attended, a two-way communication system shall have a timed automatic telephone dial-out capability to a monitoring location or 911. The two-way communication system shall include both audible and visible signals.

85mm

EMERGENCY PHONE

1007.8.2 Directions

Directions for the use of the two-way communication system, instructions for summoning assistance via the two-way communication system and written identification of the location shall be posted adjacent to the two-way communication system.

1 156

Front View Scale 1:2

2 156

Two-Way Communication Identification Sign Scale NTS


114 CMA Tower Riyadh, Kingdom of Saudi Arabia

Occupancy Load [OL] Measurements, Descriptions, and Construction Details

IBC — 2009 1004.3 Posting of Occupant Load

Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent.

Message etched and filled

1 mm

1 159

Front View Scale 1:1

10mm 10mm 30mm

90mm

50

10mm

Maximum Occupancy

10mm

10mm

10mm

160mm

2

Side View

159

Scale 1:1


115 CMA Tower Riyadh, Kingdom of Saudi Arabia

Powered Door Leaf Sign [PD] Measurements, Descriptions, and Construction Details

NFPA 101 — 2009 7.2.1.9* Powered Door Leaf Operation

7.2.1.9.1* General. Where means of egress door leaves are operated by power upon the approach of a person or are provided with power-assisted manual operation, the design shall be such that, in the event of power failure, the leaves open manually to allow egress travel or close when necessary to safeguard the means of egress.

Tactile exit sign required

7.2.1.9.1.1 The forces required to manually open the door leaves specified in 7.2.1.9.1 shall not exceed those required in 7.2.1.4.5, except that the force required to set the leaf in motion shall not exceed 50 lbf (222 N).

20mm 60mm

EXIT

4mm

7.2.1.9.1.2 The door assembly shall be designed and installed so that, when a force is applied to the door leaf on the side from which egress is made, it shall be capable of swinging from any position to provide full use of the required width of the opening in which it is installed. (See 7.2.1.4.)

60mm from edge of door

IN EMERGENCY, PUSH TO OPEN

25mm

20mm

7.2.1.9.1.3 A readily visible, durable sign in letters not less than 1 in. (25 mm) high on a contrasting background that reads as follows shall be located on the egress side of each door opening: IN EMERGENCY, PUSH TO OPEN 7.2.1.9.1.4 Sliding, power-operated door assemblies in an exit access serving an occupant load of fewer than 50 that manually open in the direction of door leaf travel, with forces not exceeding those required in 7.2.1.4.5, shall not be required to have the swing-out feature required by 7.2.1.9.1.2. The required sign shall be in letters not less than 1 in. (25 mm) high on a contrasting background and shall read as follows: IN EMERGENCY, SLIDE TO OPEN

25mm

Vinyl adheres to door

1 162

Powered Door Leaf Signs Scale 1:5

2 162

Typical Elevation Scale 1:25


116 CMA Tower Riyadh, Kingdom of Saudi Arabia

Delayed Egress Door and Powered Door Leaf Sign [DE][PD] Material Identification Material Identification Refer to Material Identification Section

A

A

1 163

CMA Delayed Egress Locking Systems Scale NTS

A

2 163

CMA Powered Door Leaf Sign Scale NTS

Legend Type and Divider Line Legend and divider line to be cut out with gray vinyl matching PMS Cool Gray 11C and applied directly to surface of legend plate.

MAT

VY


117 CMA Tower Riyadh, Kingdom of Saudi Arabia

Fabricated Cut Out Logo [CO] Material Identification Material Identification Refer to Material Identification Section

A

Size to be proportionally scaled to wall size. Consult architect/designer for size and location

A

75mm

Install at high sight line above obstructions proportional to size of wall

75mm

Reception desk

B

NOTE: Final logo TBD; drawings for illustration purposes only

1 164

CMA Fabricated Logo Scale 1:30

2

Isometric

164

Scale NTS

B

Logotype 75mm chrome polished dimensional fabricated letters pin mounted flush to the wall. Stainless steel faces and sides with crisp edges, square corners and clean lines. Logo Stainless steel sides. Clear acrylic face and backer sandwich digitally output film graphics. Internally illuminated.

MAT

SS

MAT

SS

MAT

CA


118 CMA Tower Riyadh, Kingdom of Saudi Arabia

Desk Display [DE] Material Identification

Material Identification Refer to Material Identification Section

A

B

A

Plate Clear acrylic serves as protective glass to paper insert. Must be optically clear without detracting from image quality. Bevel and finish all edges. Legend Type R-Cast. Gray matching PMS Cool Gray 11C. Fabricated dimensional letters applied on stainless steel surface.

MAT

CA

MAT

TA

MAT

CA

MAT

CA

B C

C D

Structure Clear acrylic serves as protective glass to paper insert. Must be optically clear without detracting from image quality. Bevel and finish all edges.

D Crystalline Facet Acrylic to be cut and formed to shape of facet. All films are laminated together and sandwiched between acrylic block and opaque white backing (see section of Crystalline Graphic Film for details).

1 166

Isometric for Material Identification Scale NTS

MAT

CF


119 CMA Tower Riyadh, Kingdom of Saudi Arabia

Window Vinyl [WV] Material Identification Material Identification Refer to Material Identification Section Final copy to be determined by PMT A

B

A

Sun. — Thurs. 0:00 - 00:00 Fri. — Sat. 0:00 - 00:00

C

123-456-7890

Business Hours:

Sun. — Thurs. 0:00 - 00:00 Fri. — Sat. 0:00 - 00:00 Tower Security 123-456-7890

1 167

Window Vinyl Scale 1:25

400mm

C

Accessible No Photos No Smoking

B

Graphic Band High quality digital print out on clear film. Vinyl to be applied in the interior glass surface. Final art available in 4 patterns of 800mm by 400mm. Tile pattern randomly for continuous look. Area for Pictograms and/or Prohibitive Messages Vinyl cut out letters and pictograms. Gray matching PMS Cool gray 11C (see section of Icons and Pictographs for more options). Area for Business and Contact Information Vinyl cut out letters. Silver metallic vinyl, UV rated (see section of Typography for type usage information).

MAT

GF

MAT

VY

MAT

VY

MAT

DO


Exterior Signage Details of North, South, and Plaza Announcer


121 CMA Tower Riyadh, Kingdom of Saudi Arabia

Major Tower Announcers Locations on Plan

Sized for visibility at the range of 50 ft. (15.25m) or more from the viewer. All announcers must be properly illuminated using external and internal light source. Dimensional announcers are preferred for multi-directional viewing.

North

North and South Entrance Design of grand announcer to complement the triangular form of the architecture opening to the entrance. To be positioned within the limits of work and fully visible to viewers in vehicles entering the drop-off. Plaza Announcer Adding CMA Tower presence to passing traffic or surrounding buildings in the southeastern direction of the tower. Announcer at this location can also serve as an artistic feature to the spacious plaza.

South

Plaza

Line of Sight


122 CMA Tower Riyadh, Kingdom of Saudi Arabia

North Exterior Announcer Measurements, Descriptions, and Construction Details Measurements in millimeters

Design Intent Highest quality materials and utmost level of workmanship required in the fabrication of the sign’s structure. Serves as premier entry marker, sign’s primary purpose is to “present” the tower’s logo in a regal, prestigious, and attractive way. The intent is to exemplify the crystalline quality of a gem stone unearthed from the ground.

1

180

Fabrication Notes & Requirements 1477

Parts and components must be made to fit with minimum amount and size (>1mm of opening seams) of visible seams. The choice of materials must be weather resistant and durable under local weather conditions. UV coating (to resist color fading) and non-glare coating on glass, acrylic, and other reflective surfaces is highly recommended. Use non-corrosive metal alloys but stainless steel is preferrable as the main building material.

2480

Area for Logo Logo TBD / choose option of logo suitable for horizontal layout

1003

Internal Lighting Consult lighting designer / electrician for specifications. External Lighting Consult lighting designer / electrician for specifications. Color-treated Glass Use a fade-resistant color process. Structural Consult structural engineer for review prior to fabrication. 4000

1

Front View

171

Scale 1:20


123 CMA Tower Riyadh, Kingdom of Saudi Arabia

North Exterior Announcer Measurements, Descriptions, and Construction Details

2363

1

181

1477

156

2480

Viewing Direction 18

1003

20

578

1 172

Right Side View Scale 1:20

4000

2

Rear View

172

Scale 1:20


124 CMA Tower Riyadh, Kingdom of Saudi Arabia

North Exterior Announcer Measurements, Descriptions, and Construction Details

4000

578

206

Back glass: color-treated glass

Clear acrylic logo with metal veneer as face

Front glass: clear tempered glass

Viewing Direction

1

Plan View

173

Scale 1:15

Back glass: color-treated glass

Viewing Direction

2 173

Plan View — Sans Logo Scale 1:15

Spot lighting aim upward at logo; lights to inset within structure


125 CMA Tower Riyadh, Kingdom of Saudi Arabia

North Exterior Announcer Facets Identification of Base Structure — Front

2365

438

1255

487

185

Upper Platform Surface Surface

3

5

Surface

9

Surface

2

10

Surface

1003

Surface

Surface

6

8

Surface

1

Surface

Surface

4

Footprint

133

748

211

345

1024

4000

1 174

Front Geometric Surfaces Scale 1:20

Surface

7

11

660

879


126 CMA Tower Riyadh, Kingdom of Saudi Arabia

North Exterior Announcer Facets Identification of Base Structure — Front

2

Surface

Surface

FS

9

5

Surface

18

Surface

19

Surface

11

3

FS

Surface Surface

1

1 175

Geometric Surfaces Scale NTS

Surface

2

Surface

3

10

Surface Surface

4

6

Surface Surface

7

8


127 CMA Tower Riyadh, Kingdom of Saudi Arabia

North Exterior Announcer Facets Identification of Base Structure — Rear

2365

946

815

604

Surface

Surface

12

Surface

13

18

Surface

Surface

1003

17

15

Surface

18

Surface

Surface

16

14

Surface

19

1660

1625

4000

1 176

Rear Geometric Surfaces Scale 1:20

715


128 CMA Tower Riyadh, Kingdom of Saudi Arabia

North Exterior Announcer Facets Identification of Base Structure — Rear

Surface

13

Surface

18

Surface

19

Surface

17

Surface

19

Surface

12

Surface Surface

14

1 177

Rear Geometric Surfaces — Isometric View Scale NTS

Surface

15

16


129 CMA Tower Riyadh, Kingdom of Saudi Arabia

North Exterior Announcer Material Identification Material Identification Refer to Material Identification Section

A

B B B

B

C C D

C

E

A

1

Isometric for Material Identification — Front Scale NTS

Laminated Tempered Glass Low iron starphire laminated tempered glass with ultra clear interlayers. All edges, exposed or unexposed to viewing, must be blemish-free and polished. Anti-glare finished. Color-treated Tempered Glass Glass to be chemically colored matching PMS 2607C (purple) and PMS 2945C (blue). All edges, exposed or unexposed to viewing, must be blemish-free and polished.

Logotype (Clear Varia Ecoresin XT) D Non-glare smooth finish exterior grade ecoresin. Optically clear. Bevel and finish all edges. Fabricated dimensional letters. Bevel and finish all edges.

E

178

Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish.

A

2 178

Isometric for Material Identification — Rear Scale NTS

Logotype (Aluminum) Aluminum cut out letters applied directly on clear resin dimensional letters.

MAT

SS

MAT

LT

MAT

CT

MAT

CV

MAT

AL


130 CMA Tower Riyadh, Kingdom of Saudi Arabia

North Exterior Announcer Measurements, Descriptions, and Construction Details Dimensional logo (see section on Exterior Announcer Logo)

5 Back Glass: 20mm

color-treated glass

Components of Logo Glass Display The creation of a weather-sealed cabinet to safely house the dimensional logo by using the basic components as listed in order below. Guide Rail Guide Rail: Stainless steel rail to secure (using additional fasteners) the front glass, side glass, and back glass together as a single, rigid structure. Seal to resist from weather and other exterior elements

4

2

Spot lights inset within cavity structure; actual number of units may vary; refer to lighting consultant. Option to use kinetic I-cove lighting if space is constrained

Laminated Glass: 1 13mm clear laminated glass

Viewing Direction

Area of glass that inset in base structure

1 179

Isometric View of Glass Layering Scale NTS

3 Side Glass:

13mm clear laminated glass; comprised of two panes of glass with miter joint forming the angular tip at top

Stainless steel structure


200

Side Detail Scale 1:10

1

115

Logo

Logo

Back glass

Front glass

Side sealer glass

2

Scale 1:1

Internal support structure (consult structural engineer for exact construction)

5mm stainless steel exterior skin

Spot Light Option to use Color Kinetics I-cove if space is constrained

Open cavity for lights; approximately 400mm deep and 115mm wide

Open to ground for electrical

Anchor bolts; number of units TBD by structural engineer

Open space

Bevel

Side View of Bevel Detail

Sealer guide rail

180

2

Beveling Slightly bevel and smooth finish all exposed edges of glass. Inset at least 2mm for bevels.

North Exterior Announcer

180

Allow space for supporting electrical components

Open space

5mm stainless steel exterior skin

95

Viewing Direction

2

180

131

CMA Tower Riyadh, Kingdom of Saudi Arabia

Section View


132 CMA Tower Riyadh, Kingdom of Saudi Arabia

North Exterior Announcer Measurements, Descriptions, and Construction Details

Sealer guide rail Sealant; weather-sealed seams in glass 13

24

75

10

24

5

20

Miter cut sealer guide rail and glass for exact fit Fasteners

Back glass (shaded)

Drilled opening in glass Front glass

Stainless steel fastener (install flush to surface of glass)

Back glass

Fasteners

Weather-sealed seams

Sealer guide rail (stainless steel)

Side sealer glass; with the ends of glass panes inset/secure into sealer guide rail

Metal guide rail

Viewing Direction

Weather-sealed seams Side sealer glass

Front glass

Stainless steel fastener (install flush to surface of guide rail)

1 181

Side Detail Scale 1:3

2 181

Detail in Isometric View Scale NTS


133

North Exterior Announcer

CMA Tower Riyadh, Kingdom of Saudi Arabia

Measurements, Descriptions, and Construction Details

3

186

2

186

1

186

3

185

2

185

1

185

1 183

Indication of Section View — Front Scale 1:20


134 CMA Tower Riyadh, Kingdom of Saudi Arabia

North Exterior Announcer Measurements, Descriptions, and Construction Details

Viewing Direction

3

186

Logo

2

186

1

186

3

185

2

185

1

185

1 184

Indication of Section View — Side Scale 1:20

2 184

Indication of Section Cuts in Isometric View Scale NTS


135 CMA Tower Riyadh, Kingdom of Saudi Arabia

North Exterior Announcer Section Views

Structure Footprint

1 185

2 185

3 185

Section View Scale 1:20

Section View Scale 1:20

Section View Scale 1:20


136

North Exterior Announcer Section Views

1 186

2 186

3 186

Section View Scale 1:20

Section View Scale 1:20

Section View Scale 1:20

CMA Tower Riyadh, Kingdom of Saudi Arabia


137 CMA Tower Riyadh, Kingdom of Saudi Arabia

North Exterior Announcer Base Structure Facets Measurements

Plan View of Upper Platform 815

Footprint

605

492

441

1257

57 51

264

75

19 3

2

Plan View — Plane of Upper Platform (Measurements)

187

283

206

59

20

50

206

20

1

Footprint

948

Plan View — Plane of Upper Platform (Measurements)

187

Scale 1:30

Scale 1:30

Footprint of Base Structure 1619

371

680 1034

Plan View — Footprint of Base Structure (Measurements) Scale 1:30

215

880

4 187

343

579

436

751

3

573

193

17 7

187

436

2

414

276

25

206

111

159

1671

724

Plan View — Footprint of Base Structure (Measurements) Scale 1:30


138 CMA Tower Riyadh, Kingdom of Saudi Arabia

North Exterior Announcer Access Panels for Service and Maintenance

Viewing Direction

Side Access Panel (left)

Side Access Panel (right)

Note: Weather-proof seal all exposed edges on all detachable components Main Access Panel

Note: Weather-proof seal at edges

Note: Make accessible to light source; create detachable parts for access

1 188

Rear Isometric View Scale NTS

2 188

Front Isometric View Scale NTS


139 CMA Tower Riyadh, Kingdom of Saudi Arabia

North Exterior Announcer Measurements, Descriptions, and Construction Details 10

Fasteners

10

Guide rail and fasteners to match material and finish of base structure. Fasteners to flush with attaching surfaces and integrate fasteners inconspicuously into the overall design of the guide rail and glass panes. Illustration below shows the preferred, four rows/two fasteners per row (total of eight) arrangement only if structurally feasible. If an increase of fasteners is necessary, space out equally from top to bottom. Mirror details for the rear of the structure.

2

190

48 Guide rail

48 Position of fastener

Position of fastener Fastener Row 1 Guide rail

eq.

Row 1

Fastener Row 2

5

5

eq.

Fastener Row 3

eq.

Fastener Row 4

2 190

Detail Vew Scale 1:4

Fasteners install flush / close to flush to glass surface. Weather-proof lining to seal. Approximately 10mm in diameter, decrease diameter size to minimum if possible.

Weather-proof seal lining (clear or neutral color preferred)

Glass pane

3

1

Front View

190

Scale 1:20

190

Fasterner Installation Detail Scale 1:1


140 CMA Tower Riyadh, Kingdom of Saudi Arabia

Internal Support Structure North and South Announcers

Internal Support Structure for North and South Announcers The shape of the internal structure follows the basic shape of the base structure. Support structure must fit within the interior spaces of the structure and be completely hidden from view. Attach the exterior skin to the internal support structure using stainless steel beams at strategic locations. Anchor structure to ground and provide additional fasteners to secure exterior skin independently. Constructed from stainless steel (non-corrosive) and must have the capacity to support the vertical and horizontal weight of the entire structure. Consult structural engineer for calculations and final design of the structure.

Internal Support Structure

Internal Support Structure

Height of structure to clear depth of light cavity Additional anchors for securing position of external skin

Anchor structure to ground

1 191

Internal Support Structure — Front View Scale 1:25

2 191

Isometric of Internal Support Structure Scale NTS


141 CMA Tower Riyadh, Kingdom of Saudi Arabia

External Illumination North Announcer

External Illumination Use spot lighting to illuminate the structure at times of low availability of ambient light. Ground base, low profile, spot lighting units are preferrable. Position the lights angled as illustrated below to draw out the shadows and highlights created by the facets for maximum visual impact. Light output at approximately 6000K preferred. Consult lighting

Tile 800mm x 400mm

designer for details.

Sign structure to be situated within an area of 4000mm x 800mm

Low profile, ground installed lighting Light

1 192

Plan View Placement of External Illumination Scale 1:30

2

Side View

192

Scale 1:30

Prioritize light spread to focus mainly at the base structure; upper portion of the sign is internally illuminated


142 CMA Tower Riyadh, Kingdom of Saudi Arabia

South Announcer Measurements, Descriptions, and Construction Details Design Intent

1477

Highest quality materials and utmost level of workmanship required in the fabrication of the sign’s structure. Serves as premier entry marker, sign’s primary purpose is to “present” the tower’s logo in a regal, prestigious, and attractive way. The intent is to exemplify the crystalline quality of a gem stone unearthed from the ground. Note: The basic design of North and South Announcers are mirrored (with the exception of the logo) and share identical fabrication details/materials. Reference details of North Announcer when fabricating this sign.

Fabrication Notes & Requirements Parts and components must be made to fit with minimum amount and size (>1mm of opening seams) of visible seams. The choice of materials must be weather resistant and durable under local weather conditions. UV coating (to resist color fading) and non-glare coating on glass, acrylic, and other reflective surfaces is highly recommended. Use non-corrosive metal alloys but stainless steel is preferrable as the main building material.

1003

2480

Area for Logo Logo TBD / choose option of logo suitable for horizontal layout

Internal / External Lighting Use “cool white” light source at 6000K range. Consult lighting designer / electrician for approval on details prior to fabrication. Color-treated Glass Reference section on Color Specifications on Glass for details.

4000

1

Front View

193

Scale 1:20

Structural Consult structural engineer for approval on details prior to fabrication.


143 CMA Tower Riyadh, Kingdom of Saudi Arabia

South Announcer Measurements, Descriptions, and Construction Details

2363

1477

156

2480

Viewing Direction 18

1003

20

578

1 194

Left Side View Scale 1:20

4000

2

Rear View

194

Scale 1:20


144 CMA Tower Riyadh, Kingdom of Saudi Arabia

External Illumination South Announcer

External Illumination Use spot lighting to illuminate the structure at times of low availability of ambient light. Ground base, low profile, spot lighting units are preferrable. Position the lights angled as illustrated below to draw out the shadows and highlights created by the facets for maximum visual impact. Light output at approximately 6000K preferred. Consult lighting

Tile 800mm x 400mm

designer for details.

Sign structure to be situated within an area of 4000mm x 800mm

Low profile, ground installed lighting Light

1 195

Plan View Placement of External Illumination Scale 1:30

2

Side View

195

Scale 1:30

Prioritize light spread to focus mainly at the base structure; upper portion of the sign is internally illuminated


145 CMA Tower Riyadh, Kingdom of Saudi Arabia

Plaza Announcer Measurements, Descriptions, and Construction Details Measurements in millimeters

Design Intent

1

198

One of the first signs to be seen as one arrives at one of the tower’s main entrances. Highest quality materials and utmost level of workmanship is required in the fabrication of the sign’s structure as the sign’s primary purpose is to “present” the tower’s logo in a regal, prestigious, and attractive way. The inspiration is taken from a precious gem stone unearthed from the ground, therefore, a portion of the sign is embedded in the ground.

3060

Area for Logo Logo TBD (approximately 40mm border around edges); choose option of logo suitable for horizontal layout

490

1375

2937

1185

The total height of 3060mm is calculated with the 10mm base plate

Fabrication Notes & Requirements Parts and components must be made to fit with minimum amount and size (>1mm of opening seams) of visible seams. The choice of materials must be weather resistant and durable under local weather conditions. UV coating (to resist fading) and non-glare coating on glass, acrylic, and other reflective surfaces is highly recommended. Use non-corrosive metal alloys but stainless steel is preferrable as the main building material. Use flexible seals or cushion at seams whenever possible to resist expansions and contractions at joints. Internal Lighting Consult lighting designer / electrician for specifications. External Lighting Consult lighting designer / electrician for specifications. Color-treated Glass Use a fade-resistant color process. For color accuracy, see specification on color-treated glass.

4800

1

Front View

196

Scale 1:25

Structural Consult structural engineer for review prior to fabrication.


146 CMA Tower Riyadh, Kingdom of Saudi Arabia

Plaza Announcer Measurements, Descriptions, and Construction Details

65

Viewing Direction

Viewing Direction

3060

1685

The total height of 3060mm is calculated with the 10mm base plate

800

1 197

Right Side View Scale 1:25

2

Rear View

3

197

Scale 1:25

197

Left Side View Scale 1:25


3050

Open space

Open space

LED units

Color-treated glass

Front View Scale 1:10

1

Open space

Open space

Seal

10mm stainless steel base plate

Anchor bolts; lift structure off the ground by 10mm to allow for air circulation. Number of bolts TBD by structural engineer

Internal support structure (consult structural engineer for exact construction)

3mm stainless steel exterior skin

LED lighting: Color Kinetics I-Cove lighting. Final specifications TBD by lighting designer

Flexible seals used around edge of glass permitting thermo expansion of glass

Structure

Glass

Open cavity for lights; approximately 150mm deep and 115mm wide

Logo (see section on logo buildup)

Viewing Direction

Plaza Announcer

198

20

Open space

150

3mm stainless steel exterior skin

147

CMA Tower Riyadh, Kingdom of Saudi Arabia

Measurements, Descriptions, and Construction Details

20


148 CMA Tower Riyadh, Kingdom of Saudi Arabia

Plaza Announcer Measurements, Descriptions, and Construction Details

Fasteners

60

60

Ground embedment graphics with internal illumination

Metal crossing with etched pattern

Exposed fastener

60 400

2000 60

Announcer structure Viewing Direction

1

Plan View

199

Scale 1:25

800

571

448

60mm wide metal cover


149 CMA Tower Riyadh, Kingdom of Saudi Arabia

Plaza Announcer Measurements, Descriptions, and Construction Details 523

823

823

Surface

5

Surface

3

655

711

1

1375

Surface

Surface

2

523

Surface

Surface

4

6

1194

452

2169

Surface

7

1 200

Geometric Surfaces — Base Structure (Front View) Scale 1:25

Surface

8


150 CMA Tower Riyadh, Kingdom of Saudi Arabia

Plaza Announcer Measurements, Descriptions, and Construction Details

2936 1126

1810

Upper Platform

Surface

Surface

13

1024

10

Surface

Surface

9

11

Surface

Surface

12

Surface

14

15

Footprint

878

142

1119

1330

4800

1 201

Geometric Surfaces — Base Structure (Front View) Scale 1:25

802

529


151 CMA Tower Riyadh, Kingdom of Saudi Arabia

Plaza Announcer Measurements, Descriptions, and Construction Details

Surface

3

Surface

5

Surface

1

Surface

6

Surface

2

Surface Surface

2

4

8

FS

Surface

7

3

FS

Surface Surface

9

1 202

Geometric Surfaces — Base Structure (Front View) Scale 1:25

10

Surface Surface

11

Surface

12

Surface

13

Surface

14

15


152 CMA Tower Riyadh, Kingdom of Saudi Arabia

Plaza Announcer Measurements, Descriptions, and Construction Details

2894

673

1233

Surface

19

Surface

Surface

17

Surface

Surface

16

Surface

18

22

1472

1654

4800

1 203

Geometric Surfaces — Rear View Scale 1:25

1652

20

Surface

384

21

1290


153 CMA Tower Riyadh, Kingdom of Saudi Arabia

Plaza Announcer Measurements, Descriptions, and Construction Details

Surface

19

Surface

Surface

Surface

21

17

8

Surface

20

Surface Surface

18

Surface

16

1 204

Geometric Surfaces — Rear View Scale 1:25

22

Surface

7


154 CMA Tower Riyadh, Kingdom of Saudi Arabia

Plaza Announcer Material Identification A

Material Identification Refer to Material Identification Section

A

B

B

B

C

(see section on Ground Embedment)

C B

A

B

C

Logo (Clear Resin and Aluminum) See section on Dimensional Logo A

1 205

Isometric for Material Identification — Front Scale NTS

Laminated Tempered Glass Low iron starphire laminated tempered glass with ultra clear interlayers. All edges, exposed or unexposed to viewing, must be blemish-free and polished. Non-glare finish. Color-treated Tempered Glass Glass to be chemically colored matching PMS 2607C (purple) and PMS 2945C (blue). All edges, exposed or unexposed to viewing, must be blemish-free and polished.

Logotype (Clear Varia Ecoresin XT) D Non-glare smooth finish exterior grade ecoresin. Optically clear. Bevel and finish all edges. Fabricated dimensional letters. Bevel and finish all edges.

E

A

Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish.

Logotype (Aluminum) Aluminum cut out letters applied directly on clear resin dimensional letters.

MAT

SS

MAT

LT

MAT

CT

MAT

CV

MAT

SS


155 CMA Tower Riyadh, Kingdom of Saudi Arabia

Plaza Announcer Material Identification Material Identification Refer to Material Identification Section

A

B

A

A C

B B

C

(see section on Ground Embedment)

D

A

1 206

Isometric for Material Identification — Rear Scale NTS

B

C

(see section on Ground Embedment)

Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish. Laminated Tempered Glass Low iron starphire laminated tempered glass with ultra clear interlayers. All edges, exposed or unexposed to viewing, must be blemish-free and polished. Color-treated Tempered Glass Glass to be chemically colored matching PMS 274C (purple) and PMS 300C (blue). All edges, exposed or unexposed to viewing, must be blemish-free and polished.

D Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish.

Faceted crystalline pattern to be etched and filled on stainless steel structure (see section of Faceted Crystalline Pattern for details).

MAT

SS

MAT

LT

MAT

CT

MAT

SS

MAT

EG


156

Plaza Announcer

CMA Tower Riyadh, Kingdom of Saudi Arabia

Measurements, Descriptions, and Construction Details

3

211

2

211

1

211

3

210

2

210

1

210

3

209

2

209

1

209

1 207

Indication of Section View — Front Scale 1:25


157 CMA Tower Riyadh, Kingdom of Saudi Arabia

Plaza Announcer Measurements, Descriptions, and Construction Details

3

211

Viewing Direction

2

211

1

211

3

210

2

210

1

210

3

209

2

209

1

209

1 208

Indication of Section View — Side Scale 1:25

2 208

Indication of Section Cuts in Isometric View Scale 1:25


158 CMA Tower Riyadh, Kingdom of Saudi Arabia

Plaza Announcer Section Views

Structure Footprint

1 209

Section View Scale 1:25

Open Space

2 209

Section View Scale 1:25

Open Space

3 209

Section View Scale 1:25


159 CMA Tower Riyadh, Kingdom of Saudi Arabia

Plaza Announcer Section Views

1 210

Section View Scale 1:25

Upper platform

Open cavity for internal illumination

2 210

3 210

Section View Scale 1:25

Section View Scale 1:25


160

Plaza Announcer Section Views

1 211

2 211

3 211

Section View Scale 1:25

Section View Scale 1:25

Section View Scale 1:25

CMA Tower Riyadh, Kingdom of Saudi Arabia


161 CMA Tower Riyadh, Kingdom of Saudi Arabia

Plaza Announcer Base Structure Facets Measurements

Plan View of Upper Platform

Footprint 952

435

235

420

3 69

2

Plan View — Plane of Upper Platform (Measurements)

212

Scale 1:35

Footprint of Base Structure

Plan View — Plane of Upper Platform (Measurements) Scale 1:35

1654

13 0 0

1862 158

198

448

5 32 11 3 6

3

Plan View — Footprint of Base Structure (Measurements) Scale 1:35

545

71

887

650

800

802

571

602

142

212

46

92

222

377

391

428

428

383

1801

154

1

360

360

360

533

1126

212

Footprint

13 39

4 212

Plan View — Footprint of Base Structure (Measurements) Scale 1:35


162 CMA Tower Riyadh, Kingdom of Saudi Arabia

Plaza Announcer Details of Ground Embedment 1162

3638

Area of open glass

Note: Numbers provided in drawing are measurements based on calculations; obtain/use true measurements using prototype or field measurements of fabricated structure when necessary. 825

Seam cover, 60mm width; inset from the outer edges

890

1868

1769

2154

Metallic cross beam

400

2158

1

217

280

60

60

60

Area of open glass

60

2619

2751

791 928

Match exactly to adjacent contour of footprint of base structure

1

215

158 1291

1

Plan View

213

Scale 1:15

1655

1854


163 CMA Tower Riyadh, Kingdom of Saudi Arabia

Plaza Announcer Ground Embedment Layering Details

Metal cover for sealing off gaps between ground glass elements

Laminated tempered glass with adequate rigidity to support pedestrian traffic above

Ground

Color-treated laminated tempered glass

Exposed metallic cross beam LED lights

In-ground embedment (see section on Ground Embedment)

Below ground

1 214

Isometric for Material Identification — Rear View Scale NTS

2 214

Basic Compositional Layers of Ground Embedment Scale NTS


164 CMA Tower Riyadh, Kingdom of Saudi Arabia

Plaza Announcer Section View of Ground Embedment

60

A

35 15

15

A

Top Glass Panel Clear laminated glass. Glass material must be tolerant to exterior weather conditions and impact from pedestrian traffic.

B

Inside Glass Panel 10mm color-treated, laminated glass.

C

Seam Cover Stainless steel construction to protect and hide glass fasteners from view. Angle shaved at ends.

D

Horizontal Spacers Semi-rigid spacer for absorption of shock and impact in the spaces between glass and metal. Slight perforations at some points in seal as vent.

E

Sealant Layer of flexible, waterproof rubber or silicone seal to prevent the entry of water and debris into the interior of ground embedment. Compressed by seam cover from above.

F

Seam Cover Fastener Flexible to allow tension to hold seam cover in place; also to protect the adjacent edges of the top glass.

G

Electrical and LED Components Area for additional electrical devices and supporting electrical components.

H

Ground Tray Stainless steel compartment to separate electric components from ground.

I

Glass Fastener Stainless steel rod fastening all layers of materials together; top of fasteners to flush with the ground and not interfere with the seam cover.

J

LED Diode Aim light upward towards the glass panels. Neutral color output. Quantity and arrangement of diodes TBD by lighting designer.

K

Supporting Platform Structure This stainless steel structure provides a platform for the fasteners to secure to and act as support structure to the weight of glass panels.

L

Anchor Fasteners Secure ground tray to the ground.

M

Ground

3

C

30

2

E

5

10

F

D

58

D

I 35

B M

120

J

K 47

H

3

G

L H

1 215

Section View Scale 1:2

M


165 CMA Tower Riyadh, Kingdom of Saudi Arabia

Plaza Announcer Isometric View of Ground Embedment

F

A

I C

E

I

B

I

D D K

G M

H M

1 216

Isometric Section View Scale NTS

H

J


166 CMA Tower Riyadh, Kingdom of Saudi Arabia

Plaza Announcer Access Panels

Side Access Panel (left)

Side Access Panel (left)

Note: Make accessible to light source; create detachable parts for access

Side Access Panel (right)

Note: Weather-proof seal all exposed edges on all detachable components

Side Access Panel (right)

Note: Weather-proof seal at edges

Rear Access Panel

Bottom edge to clear components of ground embedment (allow approximately 3mm clearance)

1 218

Isometric for Material Identification — Rear View Scale NTS

2 218

Basic Compositional Layers of Ground Embedment Scale NTS


167 CMA Tower Riyadh, Kingdom of Saudi Arabia

Plaza Announcer Internal Support Structure

Welded connection

Internal Support Structure The shape of the internal structure follows the basic shape of the base structure. Constructed from stainless steel and constructed with the capacity to support the weight of the structure. Hidden from view and the entirety of the support structure is contained within the interior space of the exterior skin.

Internal Support Structure

Internal Support Structure

Upper platform

Upper platform aligns with the top of the logo display Silhouette of exterior skin

Silhouette of exterior skin

Base plate Additional anchors for securing position of external skin

Anchor structure to ground

1 219

Internal Support Structure — Front View Scale 1:30

Base plate

2 219

Indication of Section View — Front Scale 1:30


168 CMA Tower Riyadh, Kingdom of Saudi Arabia

Plaza Announcer Backlighting Components Details

End Cap (left) Weather-sealed. Fasten and lock to sign structure

Color-treated Tempered Glass Fasten and secure to sign structure

Insert LED components into space behind color-treated glass

Position dimensional logo in front of color-treated glass; center align within space

1 220

Backlighting Components Scale NTS

LED Columns Framework Backlighting color-treated glass and logo. Arrange diodes for evenly distributed light, quantity TBD by lighting designer. Attach diodes to framework and install on sliding tracks for ease of replacement. LED shall also be accessed from rear of framework.

End Cap (right) Weather-sealed. Fasten and lock to sign structure


169 CMA Tower Riyadh, Kingdom of Saudi Arabia

Plaza Announcer Backlighting Components Details

307 13

20

70

2 40

Allow 20mm inset

20 115

Framework for LED units LED units

Open space

eq.

Clear tempered glass

490

Open space

Aluminum plate (in form of logo shape)

2

Color-treated tempered tlass eq.

221

Viewing Direction

Clear acrylic (in form of logo shape)

20

LED framework

Viewing Direction

258

1

Side View

2

221

Scale 1:25

221

Backlighting and Logo Layering — Side View Scale 1:8

Allow 20mm inset


170 CMA Tower Riyadh, Kingdom of Saudi Arabia

Plaza Announcer Glass and Cross Beam Details

3

222

Ground embedment

Base Color (CMA brand color)

PMS 2945

Structure

Reduce color intensity to 25% of full value to retain translucency of glass. Color is intended to be a tint of the original base color. CMYK combo: C 100 / M 45 / Y 0 / K 14

2 222

Plan View of Plaza Announcer Scale NTS

Color Transition (65% PMS 2607)

Etched graphic

Base Color

PMS 2607

Etched graphic

Cross beam

Reduce color intensity to 25% of full value to retain translucency of glass. Color is intended to be a tint of the original base color. CMYK combo: C 81/ M 100 / Y 0 / K 7 280

Cross Beam with Etched Graphic Faceted pattern to be etched at least 1mm in depth and filled with gray matching PMS Cool Gray 11C. Created by diagonal and intersecting angular lines forming faceted, polygonal geometry.

1 222

Front View Scale NTS

3 222

Ground Embedment Cross Beam Graphic Scale NTS


171 CMA Tower Riyadh, Kingdom of Saudi Arabia

Plaza Announcer Ventilation Details Rear of structure

Note: Consult structural engineer for final specification

Guard Plate Secondary Vent

Air path

Additional vent opening located at the upper portion of sign

Pin hole perforations in stainless steel plate. Position inboard within the footprint of the structure

Air Duct Connecting the two compartments of ground embedment. Provide a release for trapped moisture or heated air. Note: Install small grade mesh to prevent insects from entering structure

Air path

Base Plate

Include small perforations of >2mm to allow air from interior of structure to exit throught main vent

Main Vent Structure lifted off ground with 10mm clearance for air to exit structure and ground embedment. Follows the contour of the footprint

10 Ground

Embedment

Bolt Air duct with valve Ground tray

Drainage for rain water / moisture

Level Vent

1 223

Air Escape Path — Rear View Scale NTS

Ground

2 223

Detail of Main Vent at Base of Structure Scale 1:2


172 CMA Tower Riyadh, Kingdom of Saudi Arabia

External Illumination South Announcer

External Illumination Use spot lighting to illuminate the structure at times of low availability of ambient light. Ground base, low profile, spot lighting units are preferrable. Position the lights angled as illustrated below to draw out the shadows and highlights created by the facets for maximum

Tile 800mm x 400mm

visual impact. Light output at approximately 6000K preferred. Consult lighting designer for details.

Allow light spread to reach the full height of the structure

Ground embedment

Cross beam to match tile height of 400mm

Sign structure to be situated within an area of 4800mm x 800mm

Low profile, ground installed lighting

1 195

Plan View Placement of External Illumination Scale 1:30

Light

2

Side View

195

Scale 1:30


173 CMA Tower Riyadh, Kingdom of Saudi Arabia

Dimensional Logo Build-Up of Dimensional Logo for North, South, and Plaza Announcer

Color-treated glass UV rated epoxy adhesive bonded

Metal face

Clear acrylic

Clear plastic resin (resistant to yellowing in sunlight)

Viewing Direction

Attach to acrylic using UV resistant epoxy adhesives

2 226

Sample Detail of Logo Layering Scale NTS

2

40

Metal face (aluminum) Color-treated Glass

Viewing Direction

Metal face

Viewing Direction

Viewing Direction

Clear plastic resin

Note: Final logo to be determined. Illustration is for placement only. Do not fabricate until logo is finalized by CMA.

1 226

Isometric View of Logo Build-Up Scale NTS

Light Source

3

Side View

226

Scale 1:3


174 CMA Tower Riyadh, Kingdom of Saudi Arabia

Specifications on Color-treated Glass North, South, and Plaza Announcer

Base Color (CMA brand color) Base Color (CMA brand color)

PMS 2945

PMS 2945

Viewable Portion

Reduce color intensity to 25% of full value to retain translucency of glass. Color is intended to be a tint of the original base color. CMYK combo: C 100 / M 45 / Y 0 / K 14

Reduce color intensity to 25% of full value to retain translucency of glass. Color is intended to be a tint of the original base color. CMYK combo: C 100 / M 45 / Y 0 / K 14

Color Transition (55% PMS 2607)

Ground Embedment Fabricate glass as one continuous piece and install as separate pieces to ensure smooth color gradation

Base Color

PMS 2607 Reduce color intensity to 25% of full value to retain translucency of glass. Color is intended to be a tint of the original base color. CMYK combo: C 81/ M 100 / Y 0 / K 7

1

North Announcer Glass Only — Front View

227

Scale 1:25 Base Color (CMA brand color)

PMS 2945 Reduce color intensity to 25% of full value to retain translucency of glass. Color is intended to be a tint of the original base color. CMYK combo: C 100 / M 45 / Y 0 / K 14

Viewable Portion

Color Transition (55% PMS 2607)

Sign Structure

Base Color

Base Color

PMS 2607

PMS 2607

Reduce color intensity to 25% of full value to retain translucency of glass. Color is intended to be a tint of the original base color. CMYK combo: C 81/ M 100 / Y 0 / K 7

2 227

South Announcer Glass Only — Front View Scale 1:25

Reduce color intensity to 25% of full value to retain translucency of glass. Color is intended to be a tint of the original base color. CMYK combo: C 81/ M 100 / Y 0 / K 7

3 227

Plaza Announcer ̶ Plan View Scale NTS


175

Credits Project Support

Acknowledgment

The HOK Visual Communications design team would like to thank our colleagues at HOK Advance Strategies, Architecture, & Interiors for their help in contributing to this effort. We also thank our consultants at Xibitz and JSAV for their insights on fabrication details and electronic media.

Individual Acknowledgment: Xibitz Chuck Plockmeyer JSAV Bill Schuermann Lerch Bates, Inc. Joe Bledsoe HOK John Bellian (Arch), Ryan Favier (Interior), Kevin Shumbera (Arch), Michael Valenzuela (Arch)

CMA Tower Riyadh, Kingdom of Saudi Arabia


Managing Complexity Through Visual Communications HOK Visual Communications can strategically plan and design the appropriate vehicle to convey your message, package your information, position your image, or promote your product. Our client experience is broad in scope and international in reach. We offer deep, knowledgeable expertise in communicating about all aspects of the built environment. We seek functional, aesthetic, and economic solutions that are flexible and durable and we fully understand the business implications of good design. Image and Identity Planning Information Media Wayfinding and Architectural Graphics Display Environments

HOK VISUAL COMMUNICATIONS 2 800 P OS T OA K BO U L E VA R D | SUIT E 3700 HO US TO N | T E X AS | 7 7056 | USA +1 7 13 407 7 700 | HO K .CO M

Condensed Edition


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.