CAPITAL MARKET AUTHORIT Y TOWER S I G N A G E S Y S T E M A N D G R A P H I C D I S P L AY S R I YA D H | K I N G D O M O F S A U D I A R A B I A
SIGNAGE AND WAYFINDING STANDARDS Prepared by HOK Visual Communications
2 CMA Tower Riyadh, Kingdom of Saudi Arabia
Signage System and Graphic Displays Signage and Wayfinidng Standards
Table of Contents
Sign Family Presented as Overarching Solution Acknowledgement The HOK Visual Communications design team would like to thank our colleagues inside HOK Advance Strategies, Architecture, & Interiors for their help in contributing to this effort. We also thank our consultants at Xibitz and JSAV for their insights on fabrication and electronic media.
3
Overview 1.1 Materials 1.2 Directional Arrows 1.3 Patterns
Translations
1.4 Typography
In this document we have used for all Arabic translations. This was done specifically to avoid errors in translation. It is of course offered as a placeholder only and final translations will be completed by a professional language translator chosen by owner.
1.5 Icons and Pictographs 1.6 Mapping Graphics 1.7 Tale of Two Brands 1.8 Typical Installations
Naming The destination names used in this sign package are placeholders for illustration purposes only.
22
Interior Signage 2.1 Freestanding Interior Signs 2.2 Overhead Interior Signs
Colors
2.3 Wall Mounted Interior Signs
The color rendition of the signs within this book will vary depending on quality and calibration of both the monitor the digital files will be viewed on and the printer used to acquire hard copies. Use the Pantone Matching System as a guide to achieve the desired colors. True references should be made by obtaining actual sample materials from the manufacturer.
2.4 Vinyl Graphics and Fabricated Letterforms 2.5 Architectural Notions and Graphic Displays 168
Exterior Signage 3.1 North Announcer 3.2 South Announcer 3.3 Plaza Announcer
228
Specifications
Materials, Patterns, Graphic Film, and Other Details Descriptions and Processes
4 CMA Tower Riyadh, Kingdom of Saudi Arabia
Materials Descriptions of Materials for Use in All Sign Types
Materials Identification Overview of construction materials for all sign types including code-required (ANSI / NFPA / IBC) regulatory signs, ceiling mounted signs, wall mounted signs, and freestanding signs.
SS
AL
VL
MA
SC
LL
For its high aesthetic qualities, excellent durability against impact, and anti-corrosive properties. Steel to be stainless marine grade type 316 with satin, medium horizontal brush finish.
Chosen for its close resemblance to stainless steel and for its wide variety of gauges, sheet sizes, and finishes.
Non-glare, matte finish, high quality ,self-adhesive, die-cut vinyl material. All vinyl is cut with smooth edges.
Thin, high holding power, nickel plated, magnetic block, high resistance to demagnetization.
Commercial quality "aircraft grade" cable is made from galvanized steel wire. Galvanized aircraft cable provides high tensile strength and adequate corrosion resistance for most applications.
Philips eW Graze Powercore, outdoor rated, evenly lit, high performance illumination and beam quality LED lights. Linear lighting fixture optimized for surface grazing and wall-washing applications requiring high quality white.
Stainless Steel
Aluminum
Aluminum should replace stainless steel in the event that weight proves to be an issue for ceiling suspended signs.
Vinyl
Magnetic Block
Suspension Cable
Consult structural engineer for exact specifications.
LED Lighting
5 CMA Tower Riyadh, Kingdom of Saudi Arabia
Materials Descriptions of Materials for Use in All Sign Types
Materials Identification Overview of construction materials for all sign types including code-required (ANSI / NFPA / IBC) regulatory signs, ceiling mounted signs, wall mounted signs, and freestanding signs.
CA
GL
CV
CT
TA
Strong, light weight (half as much as glass), and resists aging under a wide range of temperatures. Transparent as the finest optical glass while providing excellent light transmission.
Non-glare coated and optically clear without color cast of color when viewed at any angle.
Non-glare, smooth finish, exterior grade ecoresin. Strong, light weight, allowing for easy fabrication and maximum installed durability. UV-rated against yellowing in exterior environments.
Strong and durable, can bear rapid temperature change. Glass to be chemically colored matching PMS 2607C (purple) and PMS 2945C (blue).
Basic attributes identical to clear acrylic. The color specifications of tinted acrylic are the same throughout the document (RCast, gray matching PMS Cool Gray 11C) unless noted otherwise. Tinted acrylic is to be used primarily as the material for legend text as noted. Acrylic material to endure fine cutting, sanding, polishing, and other methods of finishing without defects.
Clear Acrylic
Diamond polish all exposed edges for smooth and glossy finish.
Optically Clear Glass
All edges exposed or unexposed to viewing must be blemish-free and polished.
Clear Varia Ecoresin XT
All edges must be blemishfree and polished.
Color-Treated Glass
All edges exposed or unexposed to viewing must be blemish-free and polished.
Tinted Acrylic
LT
Laminated Tempered Glass Low iron starphire laminated tempered glass with ultra clear interlayers. Low iron content decreases the green tint characteristic of standard clear glass. This allows more light to pass through the glass. All edges exposed or unexposed to viewing must be blemish-free and polished.
6 CMA Tower Riyadh, Kingdom of Saudi Arabia
Materials Descriptions of Materials for Use in All Sign Types
Materials Identification Overview of construction materials for all sign types including code-required (ANSI / NFPA / IBC) regulatory signs, ceiling mounted signs, wall mounted signs, and freestanding signs.
DF
GF
DA
CF
EG
DO
White translucent acrylic panel, light weight, non-yellowing, excellent light diffusion without losing light efficiency. Distributes light evenly across entire surface and creates softer, unfocused light.
Optically clear graphic film, smooth suface captures digital four-color output, allows transparent and translucent images. Clear self-adhesive back.
Indication of a direction in a sign’s message is presented by a dimensional acrylic arrow. The arrow is a solid piece of clear acrylic with corners and edges beveled and rounded. Diamond polish the surfaces for a smooth, glossy finish. The source of color and graphic is the digital output underneath which is attached to the arrow using clear adhesives.
The iridescent, translucent, and vibrant qualities of the crystalline graphics are achieved through the layering of several different materials—each with its unique visual quality—and laminated as a single film. The laminated film is always placed behind a clear acrylic block or panel for protection.
Line and legend to be etched just adequate to be visible.
For Backlit Displays only (Light Box): Kodak Professional Duratrans Display Material for brilliant display transparencies from color negatives or internegatives. For Other Non-Backlit Inserts: Paper or other quality printable substrates are acceptable. Smooth, non-glossy finish. Art output recommended at the highest possible quality settings to be used (200 dpi minimum at actual size) for legibility of small type. Full color (CMYK minimum) process.
Diffuser
Graphic Film
Directional Arrow
Crystalline Graphic Film
Note: In applications where the film is backlit and necessary for light transmission, use WITHOUT opaque white backing.
Etched Graphic
Faceted pattern to be etched at least 1mm in depth and filled with gray matching PMS Cool Gray 11C. It is created by diagonal and intersecting angular lines forming faceted, polygonal geometry. (See sections of Faceted Crystalline Pattern and Etched Type and Graphics for details)
Digital Output
7 CMA Tower Riyadh, Kingdom of Saudi Arabia
Directional Arrow Usage and Details
Clear acrylic with diamond polished surface and edges
Forward
90°
(Align to center of arrow)
Digital output with three color fields (to further simulate dimensionality of arrow) and fit the flat surface at the underside arrow. Color side facing and visble to viewer.
45°
Forward and/or Level Change Up
135°
For output, use file directional_arrow_art.ai
DA
Directional Arrow Indication of a direction in a sign’s message is presented by a dimensional acrylic arrow. The arrow is a solid piece of clear acrylic with corners and edges beveled and rounded. Diamond polish the surfaces for a smooth, glossy finish. The source of color and graphic is the digital output underneath which is attached to the arrow using clear adhesives.
1
Dimensional View
7
NTS
180°
0° Left
Clear acrylic
Right
315°
225°
Layer of clear adhesive
Level Change Down
Digital output
Layer of clear adhesive (adhere to structure)
2
Dimensional View
3
Orientations of Arrow
7
NTS
7
Scale 1:4
Level Change Down
8 CMA Tower Riyadh, Kingdom of Saudi Arabia
Directional Arrow Measurements 55 6
40
8
All corners are beveled and rounded. Create a rounded ridge, 1mm width, along the edges of the acrylic arrow.
1
55
120° 25°
35°
1
Plan View
6
Detail View
8
Scale 1:1
8
Scale 3:1
1
Detail of rounded ridge
1
1
16
60° 30°
2
Top View
4
Plan View
7
Detail View
8
Scale 1:1
8
Scale 2:1
8
Scale 3:1
Top View
8
Detail View
Scale 2:1
8
Scale 3:1
55
7 7
1 8 8
16
115° 45°
3
Right Side View
8
Scale 1:1
20°
5 8
9 CMA Tower Riyadh, Kingdom of Saudi Arabia
Crystalline Graphic Film Film Selection, Layering, and Lamination
Usage For sign type in which the use of Crystalline Graphic Film is specifically noted. This film is to be used with clear acrylic (flat panel or shaped) at all times for rigidity and protection.
Film Composition and Other Components The three components of the film are highlighted in the blue and white boxes.
Opaque White Backing (for non-backlit application ONLY)
SOLYX Clear Icicles SOLYX Bahama HDTE Film (digitally printed)
CF
Crystalline Graphic Film The iridescent, translucent, and vibrant qualities of the crystalline graphics are achieved through the layering of several different materials—each with its unique visual quality—and laminated as a single film. The laminated film is always placed behind a clear acrylic block or panel for protection. Note: In applications where the film is backlit and necessary for light transmission, use WITHOUT opaque white backing.
Acrylic Block or Panel (reference Clear Acrylic) Viewing Direction
Viewing Direction
This film is created by lamination of the three films listed below without deviation from this order, from front to rear—HDTE Film (printed with graphic), SOLYX Bahama Film, and SOLYX Clear Icicles Film. Remove air bubbles or air gaps on the surface, front or back. Carefully squeegee out air gaps on the entire surface of the film to ensure a smooth surface prior to mounting. Lamination substrate and adhesives must be invisible to view and not interfere with transmission of light. Choice of lamination substrate must seal the enclosed films from moisture and dust. HDTE Clear Film This method of printing involves dye-sublimation by printing images on the substrate and then encapsulated with a top layer protecting the image below. The output must have adequate coverage and rich saturation for all subsequent films to take on the colors of this graphic as their primary color tonality.
SOLYX Bahama Film Iridescent Dichroic Polyester film. The color tonality of this film changes when viewed at different angles, but will stay mostly within the blue and purple tones. No dyes or metals are used in the construction of this film, making it possible for backlit applications. Scratch resistant coating on surface.
SOLYX Clear Icicles Film Translucent embossed vinyl film. Light scattering prisms make this film look like frosted-cut glass while giving the illusion of dimensional facets on the flat printed film. The tactile side of the film must be turned away from viewing direction in the lamination process to minimize air bubbles from appearing.
For more information on both SOLYX films: http://www.decorativefilm.com/index.asp
10 CMA Tower Riyadh, Kingdom of Saudi Arabia
Faceted Crystalline Pattern Side and Periphery Graphic Detail
Description A standard pattern is developed to appear on most freestanding and ceiling mounted sign types within the tower. This crystalline pattern takes form from a similar pattern that appears in spaces within the tower on the walls of the elevator bay and reception lobby. It is created by diagonal and intersecting angular lines forming faceted, polygonal geometry.
Usage and Cutting Details The usage of a standard pattern is compatible to use where the structural material is metal, often at the sides and other peripheral areas where a metal surface is present. The form of the pattern lends itself to expanding and contracting to accommodate various areas on signs yet retains a seamless appearance.
EG
Etched Graphic Line and legend to be etched just adequate to be visible. Faceted pattern to be etched at least 1mm in depth and filled with gray matching PMS Cool Gray 11C. Created by diagonal and intersecting angular lines forming faceted, polygonal geometry.
Pattern on the metal panel is to be processed as a continuous piece then cut into smaller pieces for visual continuity. The resulting pattern should be easily visible from a distance of <2m away. NOTE: Each sign type where this pattern appears is assigned with its own art file for fabrication. The name of the file will be indicated in the Materials & Finishes section of each sign.
Size adjustment is permissible only if the stroke weight of the etched lines are kept constant at 3mm wide across all sign types. Lines must appear depressed at a distance which means the lines must be cut with adequate depth. For this detail we recommend a depth of 1.5mm deep, or, the maxiumum depth the etching machinery allows but no less than 1mm in depth. Each line cut is to be filled with gray matching PMS Cool Gray 11C in matte finish. Bevel and sand away uneven edges prior to application of paint. Lines are to appear continuous and straight without breaks at intersections (see illustrations).
3mm stroke width 1.5mm depth Line cut Paint fill Metal panel
11 CMA Tower Riyadh, Kingdom of Saudi Arabia
Typography Visually Bilingual
The GE Dinar One font family has been chosen for all signage in Arabic. For most legends use GE Dinar One Medium.
The Gil Alt One MT font family has been chosen for all signage in English. For legends use Gil Alt One MT Light.
Occasionally, when a slightly lighter weight may be needed, use GE Dinar One Light, but avoid using for entire legend.
Occasionally, when a slightly heavier weight may be needed, use Gil Alt One MT Regular, but avoid using for entire
Use automatic leading for appropriate spacing between Arabic legends.
legend. In general, be more generous with leading than the default setting of most design applications.
Where To Find It
Where To Find It
Version of GE Dinar One Light can be found at http://www.boutrosfonts.com.
Version of Gil Alt One MT can be found at http://www.fonts.com.
Primary Typefaces - Arabic
Primary Typefaces - Latin
ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz 0123456789 GE Dinar One Light
Gil Alt One MT Light
ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz 0123456789 GE Dinar One Medium
Code regulated signage is required to use GE Dinar One Medium and Gil Alt One MT Regular
Gil Alt One MT Regular
12 CMA Tower Riyadh, Kingdom of Saudi Arabia
Typography Typographic Details for Freestanding Signs
A
B
435
45
TYPOGRAPHIC DETAILS All measurements are recorded in millimeters.
215 C
A Dividing Rule
F Arabic Legend Leading
Dividing rule is 2mm in thickness. No part of the message, both graphical or typographical, should extend beyond the dividing rule.
Use automatic leading specific to the Arabic font size for appropriate spacing. G English Legend Leading
Reception Desk
25
D
25
E
Auto F
Main Lobby Main Lobby
Auto G 55
H
45
I
20
J
13
K
35
L
B Right Margin
Use automatic leading specific to the English font size for appropriate spacing.
C Top Margin H Spacing Between Arrow and English Legend D Arabic Legend Typeface: GE Dinar One Light Auto kerning. Font size is to be determined by the measurement of alif-height as indicated in document. Alif-height can be obtained by measuring the distance between baseline to the top of ascender. See example. Top of Ascender
Alif-Height
Parking Transportation
Baseline
E English Legend Typeface: Gil Alt One MT Light Optical kerning. Font size is to be determined by the measurement of cap-height as indicated in document. Cap-height can be obtained by measuring the distance between baseline to the top of ascender. Title Case for all English messages. See example.
Elevators
Top of Ascender
Parking Transportation
1
Freestanding Typographic Detail
13
Scale 1:15
Cap-Height
Baseline
Measurement from baseline of English legend to a directional arrow. I Spacing Between Arrow and Arabic Message Measurement from arrow to top of the ascender of Arabic message. J Spacing Between Arabic Message and Dividing Rule Measurement from baseline of the Arabic message above to divider rule below. K Spacing Between Dividing Rule and English Message Measurement from divider rule to the top of the ascender of English message below. L Spacing Between English Legend and Arabic Legend Measurement from baseline of the English message to the top of ascender of Arabic message.
13 CMA Tower Riyadh, Kingdom of Saudi Arabia
Typography Typographic Details for Wall Mounted Signs
TYPOGRAPHIC DETAILS A
B
C
26
390
26
All measurements are recorded in millimeters. A Left Margin
84
Level 35 Information
D
19 12 10 25 17
E F G H I
19
J
23
K
22
L
I English Header Bottom Margin
B Dividing Rule
J Arabic Message
Dividing rule is 2mm in thickness for the header and 1mm for all others. No part of the message, both graphical or typographical, should extend beyond the dividing rule.
Typeface: GE Dinar One Light Auto kerning.
C Right Margin
Typeface: Gil Alt One MT Light Optical kerning.
D Top Margin
K English Message
L Arabic Message Top Margin
E Arabic Header Typeface: GE Dinar One Light Auto kerning. Font size is to be determined by the measurement of alif-height as indicated in document. Alif-height can be obtained by measuring the distance between baseline to the top of ascender. See example. Top of Ascender
Alif-Height
M English Message Bottom Margin N Spacing Between Arabic Message and Dividing Rule Measurement from baseline of the Arabic message above to divider rule below. O Spacing Between Dividing Rule and English Message Measurement from divider rule to the top of the ascender of English message below. P Spacing Between Arrows and Legends
Information
Baseline
22 12 8
Information
M
N O
F Spacing Between Arabic Header and Dividing Rule Measurement from baseline of the Arabic header above to divider rule below. G Spacing Between Dividing Rule and English Header Measurement from divider rule to the top of the ascender of English header below. H English Header
Information 23
23
P
P
Information
1
Wall Mounted Typographic Detail
14
Scale 1:5
Typeface: Gil Alt One MT Light Optical kerning. Font size is to be determined by the measurement of cap-height as indicated in document. Cap-height can be obtained by measuring the distance between baseline to the top of ascender. Title Case for all English messages. See example. Top of Ascender Cap-Height
Baseline
Left Arrows: Measure from the right-most part of the arrow to the left side of dividing rule. Right Arrows: Measure from the left-most part of the arrow to the right side of dividing rule.
14 CMA Tower Riyadh, Kingdom of Saudi Arabia
Icons and Pictographs For Common Uses
Egress / Safety Elevator
Service Elevator
Stair Down
Stair Up
Exit
Fire Exit
Escalator Up
Escalator Down
Fire Extinguisher
Surveillance Camera
Security
Clinic / First Aid
Amenities Cafeteria
Dining
Postal
Mushollah
Shopping
Water Fountain
Litter Disposal
Telephone
Locker Room
Parking
Prohibitory No Smoking
No Phone
No Weapons
No Exit
Restrooms Men
Women
Restroom
Accessibility
Do Not Enter
No Eating or Drinking
Attention
No Camera
Information
15 CMA Tower Riyadh, Kingdom of Saudi Arabia
Mapping Graphics Artistic Direction
Map Details and Layout All details (map art, icons, route, header....etc) found on an evacuation map are systematically arranged within a conventionally availble paper size for in-house color laser printing. However, it is recommended that the maps to be printed by a professional digital printer for high quality results. The left portion of the layout is reserved for the map art and the right portion reserved for all other typographic / graphical information.
LEVEL
This portion reserved for map art
This portion reserved for header and legend
30
Trim Line
Evacuation Plan Legend Key Elevator
Stair way
Exit Route
LEVEL
You Are Here
123- 4567 123- 4567
DO
Digital Output For Backlit Displays only (Light Box): Kodak Professional Duratrans Display Material for brilliant display transparencies from color negatives or internegatives. For Other Non-Backlit Inserts: Paper or other quality printable substrates are acceptable. Smooth, non-glossy finish. Art output recommended at the highest possible quality settings to be used (200 dpi minimum at actual size) for legibility of small type. Full color (CMYK minimum) process.
Right margin (with bleeds)
30
Level Number
Tower Security
Arabic Header
Fire Depar tment
Option for Four Color Silkscreen Printing The number of colors on the map art is reduced
Evacuation Plan
English Header
to four, thus allowing art to be screen printed directly on a variety of materials, such as glass
Legend Key
and metals. Elevator
Stair way
Exit Route
Bilingual Legend and Graphic Icons Arabic legend on top, English legend at the bottom
You Are Here
123- 4567
Tower Security
123- 4567
Fire Depar tment
Area for Additional Information For useful contact numbers or other useful instructions
16 CMA Tower Riyadh, Kingdom of Saudi Arabia
Mapping Graphics Artistic Direction
LEVEL 1
Non-Level Specific Amenities Bilingual key with Arabic column to the right and English to the left of the central column of icons. Icons are coded in contrasting colors, accompanied with graphics/symbols.
Floor Identification Header Color field behind bilingual floor level information; CMA Tower colors.
Map Art Floor map presented in isometric format. Isometric formula of art adjusted to enhance the viewer’s visibility of details to aid wayfinding. Tower structure / non-destinations illustrated in neutral shades of grey in contrast with the vibrant color scheme of icons and locations.
th ontrrance
NE
Level Specific Location Key Each location is designated with an assigned number within a green box that corresponds with the location of the amenity as it appears on the map. Three column arrangement with Arabic to the right, icons at center, and English to the left.
Men’s Restroom Escalator
1
Auditorium
Information
2
Green Room
Elevator to CMA Levels
3
VIP Lounge
Elevator to Local Levels
4
Location Name
Elevator to Mid-Rise Levels
5
Location Name
6
Location Name
7
Location Name
Levels Number 00-00
Levels Number 00-00
Levels Number 00-00 2
To p
h utnce SoEntra
You Are Here
Fr
1 3
on
t
Elevator to Parking S
id
X
e
Podium Levels Elevator X
Information Elevator to CMA Levels Levels Number 00-00
Elevator to Local Levels Levels Number 00-00
Elevator to Mid-Rise Levels Levels Number 00-00
Elevator to Parking
Extension of List
Security Check
Men’s Restroom Escalator
Extra Line Arrangement for Long Legends
Amenities Icons Non-level specific. For locations that appear on multiple levels, such as restrooms and elevators.
Podium Levels Elevator
Other Graphical Elements Additional elements, such as symbols, illustrations, and textures, are used to enhance the legibility and visual quality of the map.
Security Check
1
Legend Here
4
Legend Here
7
Legend Here
2
Legend Here
5
Legend Here
8
Legend Here
3
Legend Here
6
Legend Here
9
Legend Here
Quick Reference Security Desk
123-4567
Tower Information
123-4567
Telephone Directory
123-4567
Location Key For locations that are level specific. Quick Reference Special messages or phone numbers to tower management, etc.
You Are Here Escalator Icon paired with destination
Compass
You Are Here
Map Texture
Graphic of Exterior Features
17 CMA Tower Riyadh, Kingdom of Saudi Arabia
Tale of Two Brands Capital Market Authority Branding vs. CMA Tower Branding
Capital Market Authority Signage (For use on CMA specific floors only)
CMA Tower Signage (For use in general/public floors )
The signage for Capital Market Authority is specifically referencing the established look and feel of the corporate brand. The color reveal reflects the proximate tonality of the brand’s blue colors (PMS 2945 and PMS 2905). The diamond shape in the Capital Market Authority logo is subtly reflected in the faceted cuts and angular lines found on the signage.
The colors and form of the CMA Tower signage is complementary to the signage found on the Capital Market Authority floors yet distinctive enough to differentiate between the two brands. The basis of the tower signage emphasizes the architectural aesthetics of the tower — faceted cuts and color reveal appearing at the top edge symbolizes the “crown” at the top of the tower. The use of colors (Royal purple with a hint of blue/ sapphire colors) and typography serve as the visual connection between the brands.
NOTE: Printer must calibrate output process to achieve closest color match.
Directory
Directory
Large Conference Room
Large Conference Room
MEN
Information
Information
Information
Information
Information
Information
Information
Information
Information
Information
MEN
18 CMA Tower Riyadh, Kingdom of Saudi Arabia
Typical Installation Wall Mounting General Notes
A. Assemble, unless otherwise specified, with appropriate adhesive. No adhesive is to be visible. B. Mount assembled sign unit to wall surface with double-faced foam tape and clear silicone glue. Thickness of foam tape shall be thickness needed to achieve maximum adhesion. No adhesive is to be visible. Existing wall
1 Installing on Gypsum Wallboard (2 options)
Existing wall
Existing wood panel Double-faced foam tape
Double-faced foam tape
Double-faced foam tape
Double-faced foam tape
Double-faced foam tape
Pin (add pin in addition to tape for large signs for increased adherence)
Plastic toggle PLA screws
3mm backplate
3mm backplate
Double-faced foam tape
B. Use wall fasteners, double-faced foam tape to mount on wall. Clear acrylic backing plate. 3mm backplate
Sign Sign
A. Use double-faced foam tape and silicone glue to mount on wall. Do not use this method if wall has covering as foam tape and silicone may not adhere. Clear acrylic backing plate.
Sign
Pin
1
Installing on Gypsum Wallboard (A)
2
Installing on Gypsum Wallboard (B)
3
Installing on Wood / Wood Veneer
FS
Scale 1:2
FS
Scale 1:2
FS
Scale 1:2
2 Installing on Wood or Plywood Paneling
Mount signs with double-faced foam tape only. Do not use silicone or wall fasteners.
Interior Signage Measurements, Descriptions, and Construction Details
20 CMA Tower Riyadh, Kingdom of Saudi Arabia
Freestanding Directional [FS] Measurements, Descriptions, and Construction Details Measurements in millimeters
Fabrication Notes & Requirements
450
135
110
1
25
Etched pattern
Etched pattern
English Legend Information
Crystalline Graphic See section on Crystalline Graphic Film. Backlit with internal LED illumination. 6000K white balance. Acrylic pieces are diamond polished and install without visible seams or gaps. No fasteners shall be visible from within acrylic.
Main Lobby
Information
2045
Information
1
26
2
55
Seams should be kept to a minimum and no open gaps of more than 1mm are acceptable. Structure should be symmetrical and structurally sound. Use additional structural reinforcement (internal and hidden from view) if deemed necessary from an engineering standpoint. Exposed edges are to be beveled and smoothed-out, leaving no sharp edges that can cause injuries. If components are manufactured separately, the overall finish and color of material must be visually identical after assembly. Secure sign structure to ground using expansion bolts. Production of a full-scale, working prototype is HIGHLY RECOMMENDED for this sign type to test for structural durability, functionality, and aesthetic quality.
65
25
Base skirt
65 40 174
180
1
Small Freestanding Directional
2
Left Side View
3
Right Side View
23
Scale 1:20
23
Scale 1:20
23
Scale 1:20
21 CMA Tower Riyadh, Kingdom of Saudi Arabia
Freestanding Directional [FS] Material Identification Material Identification Refer to Material Identification Section
A
A
A
C
A
B
Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish. Structure Side (Left and Right) Stainless steel marine grade type 316 with satin, medium horizontal brush finish.
MAT
SS
MAT
SS
MAT
VY
MAT
SS
MAT
MAT
MAT
EG
CA
MAT
DA
CA
MAT
CF
Faceted crystalline pattern to be etched and filled on stainless steel structure (see section of Faceted Crystalline Pattern). E C
E
F B
B
D Base Skirt Stainless steel marine grade type 316 with satin, medium horizontal brush finish.Transparent coating to protect from scuffs and scratches.
E
F
D
1
Isometric for Material Identification
24
Scale NTS
Legend Type Gray vinyl matching PMS Cool Gray 11C. Non-glare, matte finish, high quality, self-adhesive vinyl is to be cut with smooth edges.
Directional Arrow Dimensional acrylic arrow (see section of Directional Arrow for details). For digital output, use art file: directional_arrow_art.ai
D
F
Crystalline Facet Acrylic to be cut and formed to shape of facet. All films are laminated together and sandwiched between acrylic blocks (see section of Crystalline Graphic Film for details).
22 CMA Tower Riyadh, Kingdom of Saudi Arabia
Freestanding Directional [FS] Section View and Descriptions
B
I
D
Wrapping Panel Only 3mm thick stainless steel panel with etched pattern; wrap around forming edges and securing acrylic components in place.
B
Exterior Cabinet Formed from 3mm thick stainless steel for structural durability.
C
Bottom Acrylic Block Clear acrylic block cut to shape as specified; secured to the anchor base and exterior cabinet.
D
Support Frame Extends from top of sign to ground. Provides primary support for the entire signage structure.
E
Clear Acrylic 12mm thick.
F
Crystalline Graphic Film See Crystalline Graphic Film section for more information.
G
Diffuser Backer 6mm thick acrylic.
H
Open Space
I
LED Lights
J
Steel Pegs Pegs used for securing acrylic panels or block to the external cabinet body; correspond with drilled holes in acrylic / diffuser material.
K
Stainless Steel Panel 3mm thick with etched pattern.
L
Cross Bracket Beams attaching the exterior cabinet body to the internal support structure. Do not block path of light.
M
Z Clips Securing stainless steel panel to internal support structure. Removable for accessibility for servicing and maintaining LED components.
N
Base Skirt
N
30
A
A
C
M
110
180
H
H
30
C
15
E F G
1
Section View
26
Scale 1:3
G
F
C
L
J
I
L
K
23 CMA Tower Riyadh, Kingdom of Saudi Arabia
Freestanding Directional [FS] Isometric Section View G E F
J
I B
P A
Wrapping Panel 3mm thick stainless steel panel with etched pattern visble to viewer; wrap around forming protecting edges.
K
Side Panel 3mm thick stainless steel etched with faceted crystalline pattern.
B
External Cabinet Body 3mm thick stainless steel.
L
Anchor Base Stainless steel skirt concealing leveling nuts and anchoring bolts. Secure to ground.
C
Clear Acrylic Block Block is secured to the anchor base and the external cabinet body.
D
Support Frame Extends from top to bottom and attaches to anchor base; anchors securely into base as a crucial structural component.
E
Clear Acrylic 12mm thick.
F
Crystalline Graphic Film Pattern must look continuous at completion without obvious breaks in graphic. See Material section for more information on graphic film. Note: Print crystalline graphic on one continuous piece of graphic film then cut into shape and reassemble to ensure a continuous look. Repeat process for each individual sign.
N A D K B
K
M O
C
L
1
Isometric View
27
Scale NTS
G
Diffuser Backer 6mm thick clear acrylic.
H
Open Space
I
LED Lights Drawing for instructional purposes only; consult lighting technician/designer.
J
Steel Pegs Pegs used for securing acrylic to the external cabinet body.
M Chemical Weld Joint Transparent and seamless chemical fusion at the joint of acrylic pieces. N
Cross Bracket Folded stainless steel component welded to the second surface of the external cabinent body. Fasten the opposite end to the support frame.
O
Fastener Contersinking fastener for attaching side panel to the support frame; install flush to surface of panel. 10mm in diameter. Avoid positioning fasteners over etched lines.
P
Horizontal Beam
Support Frame
Horizontal Beam
24 CMA Tower Riyadh, Kingdom of Saudi Arabia
Acrylic Crystalline Components Sign Type FS and FL
Acrylic Component on Sign Type FS
Attach to pegs
4
The acrylic used shall be clear and without any hints of color cast or frosting. Diamond polish all surfaces for a clear, glossy finish allowing light to pass through unhindered. The color and graphic comes from the crystalline graphic film (see section on Crystalline Graphic Film) and is sandwiched in between the acrylic and the diffuser backer. The entire gem-stone portion of the sign is comprised by two acrylic groups (each with 2 acrylic elements) and joined by chemical welding to join as one. Each acrylic element must be cut and polished to fit on sign body precisely without open gaps or uneven seams. Prototyping and testing is crucial to acquire accurate measurements for final production.
28
Clear acrylic piece A
Diffuser backer piece B
Crystalline graphic film
Viewing Direction
Drilled openings
4
Acrylic Component 1 â&#x20AC;&#x201D; Top Detail
28
Scale NTS
2
28
This detail is to be mirrored and repeated on the opposite side of the sign. Clear acrylic piece A
Drilled openings
5
28
Attach to pegs
Viewing Direction
3
2
Acrylic Component 1
28
Scale NTS
Crystalline graphic film Diffuser backer piece B
28
Surface to chemical weld to Acrylic Group 2 Attach to pegs
1
Acrylic Group Isometric
3
Acrylic Component 2
5
Acrylic Component 1 â&#x20AC;&#x201D; Bottom Detail
28
Scale NTS
28
Scale NTS
28
Scale NTS
25 CMA Tower Riyadh, Kingdom of Saudi Arabia
Crystalline Acrylic Components Relevant for Sign Type FS
2
30
Exterior cabinet
Support frame
Acrylic Group 1
Open space
Acrylic
Peg
Diffuser
Welded
Seam using chemical welding to join Acrylic Component 1 and 2
Stopper
Film
Crystalline graphic film; vertical strip Base skirt
2
30
Acrylic Group 2
LED
Support frame to be extended and bolted to ground
Situated at the bottom Crystalline graphic film at the underside of the acrylic; horizontal strip
1
Isometric View
2
Detail View
30
Scale NTS
30
Scale NTS
Exterior cabinet
26 CMA Tower Riyadh, Kingdom of Saudi Arabia
Access Panels for Service and Maintenence Sign Type FS
Accessibility to Internal Components
Sign type FS has two access portals for servicing and maintenance.
Side Access Panel
Top Access Panel
Side Access Panel
Tab
Located at the side opposite from the acrylic components.
Tab Welded to side access panel
Countersink fasteners; install flush with surface
Top Access Panel The top access panel is mainly for access to the LED
This port allows the technician to access components
running vertically along sign. Mount LED on sliding tracks
located at the bottom of the sign where it may be difficult
for the ability to slide LED vertically out without complete
to reach from the top access port.
disassembly of sign.
Countersinking fasteners install flush to the surface of the
Install countersinking fasteners flush to the surface of the
detachable panels. The positions of the fasteners to align
detachable panel. The positions of the fasteners to center
on the central support beam. Space out evenly (avoid
align along the top of the central support beam and space
positioning fasteners over etched lines). Allow for an
Support Frame
additional 10mm diameter fastener at the bottom of the
out evenly. Use 10mm diameter fasteners and increase quantity of fasteners if structurally necessary. Fasteners to
panel and install firmly to support beam. Fastener to match
match finish of the steel panel. The top access panel
finish of the steel panel.
compressed down to secure the side access panel.
Attach Z Clips to support frame
Attach side access panel with Z Clips (see section on Z Clips)
English Legend
English Legend
Information
Information
Main Lobby
Main Lobby
Information
Information
Information
Fastener
Information
Bottom LED on Sliding Tracks
Mount LED lights to a horizontal sliding track for ease of maintenance.
Vertical LED on Sliding Tracks Mount LED lights to vertically sliding tracks for ease of maintenance.
Divide LED lights into sections if ceiling height is low. Support Frame
1
Isometric View
2
Isometric View
31
Scale 1:15
31
Scale 1:15
27 CMA Tower Riyadh, Kingdom of Saudi Arabia
Wall Mounted Elevator Kiosk [EL] [ER] Measurements, Descriptions, and Construction Details Measurements in millimeters Fasteners Heat vents Touch screen flush
20
100mm
16mm
46mm
0m
m
Touch screen flush
1
Elevator Monitor Facing Left Plan View
2
Elevator Monitor Facing Right Plan View
3
Elevator Monitor Facing Right Bottom View
32
Scale 1:5
32
Scale 1:5
32
Scale 1:5
200mm Elevator Available Enter Level Number
Elevator Available
200mm
Enter Level Number
Enter Level Number Enter Level Number
35
1
2
3
4
5
6
7
8
9
0
This sign type is essentially a structure to house the hardware provided by the elevator consultant. The top surface of screen is completely exposed for touch-sensitive operation. Seams should be kept to a minimum and no open gaps of more than 1mm are acceptable. Use additional mounting reinforcement (hidden from view) if necessary from an engineering standpoint. Edges are to be beveled and smoothed-out; leaving no sharp edges that may cause injuries. If components are manufactured separately, the overall finish and color of material must be visually identical after assembly. Hardware and frame must be configured to fit properly and securely. Production of a full-scale, working prototype is HIGHLY RECOMMENDED for this sign type to test for structural durability, functionality, and aesthetic quality. Electronic and Digital Components Reference Elevator Package for hardware specifications. Signage fabricator responsible for frame and structural detail.
Elevator Available
Elevator Available
Fabrication Notes & Requirements
E N T E R
4
Elevator Monitor Flat Elevation
5
Front View
6
Elevator Monitor Facing Left
32
Scale 1:5
32
Scale 1:5
32
Scale 1:20
28 CMA Tower Riyadh, Kingdom of Saudi Arabia
Wall Mounted Elevator Kiosk [EL] [ER] Material Identification Material Identification Refer to Material Identification Section
A
Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish.
MAT
SS
MAT
EG
A B B
C
1
Plan View for Material Identification
33
Scale NTS
C
A
Elevator Available
Elevator Available
Enter Level Number
Enter Level Number
A
B
B
2
Isometric for Material Identification
33
Scale NTS
Faceted Crystalline Pattern Faceted crystalline pattern to be etched and filled on stainless steel structure (see section of Faceted Crystalline Pattern for details). Electronic Hardware Consult elevator consultant for more information on hardware.
29 CMA Tower Riyadh, Kingdom of Saudi Arabia
Freestanding Elevator Kiosk [EK] Measurements, Descriptions, and Construction Details Measurements in millimeters
Fabrication Notes & Requirements
237
20
E l e v a t o r Av a ila b l e Elevator Available E n t eEnter r Le vLevel e l N uNumber mber 1
2
3
4
5
6
7
8
9
0
E N T E R
20
0
200
Elev a tor Av a ila ble Elevator Available Level EnteEnter r Leve l N uNumber mber
1
2
3
4
5
6
7
8
9
0
E N T E R
3
Plan View
35
Scale 1:15
Electronic and Digital Components Reference Elevator Package for hardware specifications. Signage fabricator responsible for frame and structural detail.
225
770
1045
1210
35
200
12
30
5
Screen
This sign type is essentially a structure to house the hardware provided by the elevator consultant. The top surface of screen is completely exposed for touch-sensitive operation. Seams should be kept to a minimum and no open gaps of more than 1mm are acceptable. Structure should be symmetrical and structurally sound. Use additional structural reinforcement (internal and hidden from view) if necessary from an engineering standpoint. Edges are to be beveled and smoothed-out, leaving no sharp edges that may cause injuries. If components are manufactured separately, the overall finish and color of material must be visually identical after assembly. Hardware and frame must be configured to fit properly and securely. Secure sign structure to ground using expansion bolts. Production of a full-scale, working prototype is HIGHLY RECOMMENDED for this sign type to test for structural durability, functionality, and aesthetic quality.
10
1
Elevator Kiosk
2
Side View
4
Footprint
35
Scale 1:15
35
Scale 1:15
35
Scale 1:15
30 CMA Tower Riyadh, Kingdom of Saudi Arabia
Freestanding Elevator Kiosk [EK] Material Identification Material Identification
Ele
va
to
En
r
a Av
Le ter
v
ila
Nu el
mb
Ele
ble
En
er
B
3
2
6
1
5 8
E
N
T
E
rL e 2
4 7
ve
lN u
T
mb
B ail
ab
le
Refer to Material Identification Section
A
er
6 9
N
rA v
3
8 E
R
to
5
0
0
7
te
1
9
4
va
E
A
R
B
A
A
1
Isometric for Material Identification
36
Scale NTS
A
Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish. Electronic Hardware Consult elevator consultant for more information on hardware.
MAT
SS
31 CMA Tower Riyadh, Kingdom of Saudi Arabia
Freestanding Elevator Kiosk [EK] Isometric of Structure Geometry and Internal Details 3
37
Open and exposed to touch screen device
Open and exposed to touch screen device
Ventilation
Opening for electronic and data connections
Expansion bolts Open to ground
1
Isometric Left
2
Isometric Right
3
Isometric Section Cut
4
Isometric Rear-Right
37
Scale NTS
37
Scale NTS
37
Scale NTS
37
Scale NTS
32 CMA Tower Riyadh, Kingdom of Saudi Arabia
Freestanding Elevator Kiosk [EK] Section Cuts and Details
1
39
Bending angles: 0.25mm radius
Internal support; drawing shows approximate location only; consult structural engineer
Front Elev a tor Av a ila ble Elevator Available
Internal support and cross brace; drawing shows approximate location only; consult structural engineer
Internal support and cross brace; drawing shows approximate location only; consult structural engineer
Level EnteEnter r Leve l N uNumber mber
35
1
2
3
4
5
6
7
8
9
0
E N T E R
4
38
3
38
2
38
Open interior
Open interior
Open interior
3mm stainless steel skin
3mm stainless steel skin
3mm stainless steel skin
Front
Front
Front
1
Location of Section Cuts
2
Section Cut
3
Section Cut
4
Section Cut
38
Scale NTS
38
Scale 1:3
38
Scale 1:3
38
Scale 1:3
Section View
Scale 1:4 .5
Expansion bolts
Opening for electrical supply
Open to cabinet below for electrical and data connections
43
Approximate location of surface of touch screen. 42° viewing angle
Expansion bolts anchor to ground
Base plate; 5mm thick
5 mm diameter fastener
Internal support tube and cross brace; drawing shows approximate location/size only; consult structural engineer
3mm thick stainless steel structural shell
Removable fasteners for hardware enclosure to detach completely
Hardware enclosure: 1.5mm stainless steel skin
Freestanding Elevator Kiosk [EK]
5
1
39 770 30
Space open for installation of electronic hardware. Current dimensions to accommodate for standard 200mm x 200mm screen size. Note: Consult technician for exact configuration of electronic hardware (for exact fit) prior to fabrication
16
33
CMA Tower Riyadh, Kingdom of Saudi Arabia
Section Cuts and Details
34 CMA Tower Riyadh, Kingdom of Saudi Arabia
Freestanding Elevator Kiosk [EK] Access Panels for Service and Maintenence
Head enclosure to house electronic hardware
Accessibility to Internal Components
Surface for ventilation
3
The interior of the sign type EK can be accessed through a detachable hatch located at the rear of the kiosk, and the hardware enclosure housing the electronic hardware is fully detachable.
40
Hardware Enclosure
Additional surface for ventilation Note: Confirm dimension in drawings with actual dimensions of hardware prior to fabrication
Hardware Enclosure This structure houses the primary hardware of the kiosk in which the screen is operated from the opening of the enclosure. The electronics shall be attached securely to the hardware enclosure using custom configurations specific to the hardware used. Grooves are cut on the rear surface of the enclosure for heat dissipation; see pattern of ventilation grooves below:
Open interior for wiring and data connectors. Space available for storage of additional hardware Detachable
40
Detachable hatch
4
40
2
Access Panel
Note: Increase area for ventilation grooves as required by hardware
Attach using 5mm diameter fastener
3
Ventilation Details
40
Scale NTS
Access Panel
Drilled opening
Stainless steel detachable hatch to fit seamlessly and conforming to the geometry of the kiosk. Attach using small, inconspicuous, 5mm diameter fasteners evenly spaced along the edges of the hatch. Route out a portion of both connecting surfaces at the joints to minimize the visibility of a seam by overlapping them. 5mm fastener
Overlapping joints
1
Details of Hardware Enclosure and Access Portal
2
Details of Hardware Enclosure and Access Portal
4
Details of Surface for Fastener
40
Scale NTS
40
Scale NTS
40
Scale NTS
35 CMA Tower Riyadh, Kingdom of Saudi Arabia
Table Map [TM] Measurements, Descriptions, and Construction Details Measurements in millimeters
Fabrication Notes & Requirements 850
L E V EL 1 Menâ&#x20AC;&#x2122;s Restroom Escalator Information
North Entrance
Elevator to CMA Levels Elevator to Levels 00-00
472
Elevator to Levels 00-00 Elevator to Parking Podium Levels Elevator Security Check
2
Auditorium
1
Green Room
2
VIP Lounge
3
Legend Here
4
Legend Here
5
Legend Here
6
Legend Here
7
Legend Here
8
Legend Here
9
You Are Here
South Entrance 1 3
Quick Reference Security Desk Tower Information Telephone Director y
1
46
0
70
55 LE VEL 1 Menâ&#x20AC;&#x2122;s Restroom Escalator Information
North Entrance
Elevator to CMA Levels Elevator to Levels 00 - 00 Elevator to Levels 00 - 00
3
Plan View
41
Scale 1:15
Elevator to Parking Podium Levels Elevator Security Check
2
Auditorium
1
Green Room
2
VIP Lounge
3
Legend Here
4
Legend Here
5
Legend Here
6
7 8 9
South Entrance 3
Quick Reference Secur it y Desk Tower Infor mation Telephone Direc tor y
123- 4567 123- 4567 123- 4567
500
Legend Here Legend Here Legend Here
You Are Here
1
545
472
771
1150
850
1
Movable Stanchion
2
Right Side View
4
Footprint
41
Scale 1:15
41
Scale 1:15
41
Scale 1:15
123-4567 123-4567 123-4567
This sign type is essentially a structure to house a light box with a removable Duratrans graphic. Seams should be kept to a minimum and no open gaps of more than 1mm are acceptable. Structure should be symmetrical and structurally sound. Use additional structural reinforcement (internal and hidden from view) if necessary from an engineering standpoint. Edges are to be beveled and smoothed-out, leaving no sharp edges that may cause injuries. If components are manufactured separately, the overall finish and color of material must be visually identical after assembly. Secure sign structure to ground using expansion bolts. Production of a full-scale, working prototype is HIGHLY RECOMMENDED for this sign type to test for structural durability, functionality, and aesthetic quality. Backlit Display (Light Box Display) Use low heat light sources such as LED. 6000K white balance. Evenly distribute light without hot or dead spots on the display. Output map graphics at high resolution on Duratrans substrate.
36 CMA Tower Riyadh, Kingdom of Saudi Arabia
Table Map [TM] Material Identification Material Identification Refer to Material Identification Section
A
B
A
B
Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish. Structure Side (Left And Right) Stainless steel marine grade type 316 with satin, medium horizontal brush finish.
MAT
SS
MAT
SS
MAT
DO
MAT
GL
Faceted crystalline pattern to be etched and filled on stainless steel structure (see section of Faceted Crystalline Pattern for details).
A
C C
D
Digital Output High resolution, high quality digital map artwork on Duratrans substrate.
B D Anti-Glare Optical Glass 10mm thick optical glass serves as protective glass to digital output. Must be optically clear without detracting from image quality. Bevel and finish all edges.
A
1
Table Map Rear View
2
Table Map Front View
42
Scale NTS
42
Scale NTS
MAT
EG
37 CMA Tower Riyadh, Kingdom of Saudi Arabia
Table Map [TM] Measurements, Descriptions, and Construction Details
Fastener
Display bezel
Surface for ventilation grooves if applicable; remove etched pattern
Remove top glass panel to replace map graphic
Rear Access Panel
Display Header Access
Countersinking fasteners install flush to the
Countersinking fasteners install flush to the
surface of the detachable panel. Space out
side of the display bezel. Avoid positioning
evenly along the edge of the panel. Allow for six
fasteners over etched lines. Allow for
10mm diameter fasteners and increase quantity
approximately six 10mm diameter fasteners
of fasteners if structurally necessary. Fasteners
and increase quantity of fasteners if
to match finish of the steel panel.
necessary. Fasteners to match finish of the display bezel.
1 44
Rear Isometric View
2
Isometric View
Scale NTS
44
Scale NTS
38 CMA Tower Riyadh, Kingdom of Saudi Arabia
Table Map [TM] Measurements, Descriptions, and Construction Details
Note: Display header is muted for illustration purpose Surface
13
107
616
LE VEL 1
Escalator Information
North Entrance
Elevator to CMA Levels
10
10
Menâ&#x20AC;&#x2122;s Restroom
Elevator to Levels 00 - 00 Elevator to Levels 00 - 00 Elevator to Parking Podium Levels Elevator Security Check
2
1 2
VIP Lounge
3
Legend Here
4
Legend Here
5
Legend Here
6
Legend Here
7
Legend Here
8
Legend Here
9
You Are Here
South Entrance 1 3
Surface
Quick Reference Secur it y Desk
6
123- 4567
Tower Infor mation Telephone Direc tor y
123- 4567
Surface
123- 4567
12
Surface
2
Surface
207
10
Surface
14
500
500
178
Surface
292
Auditorium Green Room
Surface
2
Surface
4
Surface
8
10
176
Surface
1
213
86
275
86
213
Surface
7
Surface
Surface
11
3
145
30
Surface
Surface
3
145
Surface
5
152
Surface
9
110
320
11
110
1
Front View
2
Right Side View
3
Rear View
4
Left Side View
45
Scale 1:10
45
Scale 1:10
45
Scale 1:10
45
Scale 1:10
152
1 Section View
46 Scale 1:4 Expansion bolts
Internal Support Tube Drawing shows approximate location/size only; consult structural engineer
Reading surface: see Reading Surface Composite for details
Base plate
3mm exterior skin
Internal folds of exterior skin
3mm exterior skin
Support platform
Support platform
3mm exterior skin
Open space
39
Table Map [TM] CMA Tower Riyadh, Kingdom of Saudi Arabia
Measurements, Descriptions, and Construction Details
40 CMA Tower Riyadh, Kingdom of Saudi Arabia
Table Map [TM] Measurements, Descriptions, and Construction Details
Exterior Fastener Exterior Fastener 10mm diameter. Install inconspicuously and flush with surface. Match finish with enclosure. Locking surface enclosure to bottom enclosure
Open window Surface Enclosure Stainless steel, slightly larger than bottom enclosure. Fits over the top bottom enclosure
LE VEL 1 Menâ&#x20AC;&#x2122;s Restroom Escalator Information
North Entrance
Elevator to CMA Levels Elevator to Levels 00-00 Elevator to Levels 00-00
2
Elevator to Parking
47
Podium Levels Elevator Security Check
1
Section View
47
Scale 1:10
2
Auditorium
1
Green Room
2
VIP Lounge
3
Legend Here
4
Legend Here
5
Legend Here
6
Legend Here
7
Legend Here
8
Legend Here
9
You Are Here
South Entrance 1 3
Quick Reference Security Desk Tower Information Telephone Directory
123-4567 123-4567 123-4567
Exterior Fastener 10mm diameter. Install inconspicuously and flush with surface. Match finish with enclosure. Locking surface enclosure to bottom enclosure
LEV M en
Elev Elev Elev
Podi
Fastener
Map Graphic
Rubberized Cushion >2mm thick. Placed at contact points of metal and glass
Diffuser Panel
Surface Enclosure
V IP Lege Lege Lege Lege
Fastener 15mm diameter. Install through glass panel and map graphics and attach to support platform below. Flush with surface
Support Platform
Lege Lege
nd
nd
H er
nd
H er e
nd
H er e
nd
H er
e
nd
H er e
Loun
H er e
e
Roo ge
ri ty
itori
ato
r to
ato
r to
CM
A Le
ls 00
ls 00
Pa rk
ev at
Che
r to
Leve
Leve
r to
ls El
ato
Info
rmat
es tr
lato
oom
EL
1
r
ion
vels
-0 0
-0 0
ing
or
ck
um 1
m
N En o
2
tra
3
rt h
nce
4 5
6
2
7 8
9
1
3
You
Are
He
re
SEnou tra
Q ui ck Re Se cu fe re nce To w rit y D Te le er In fo es k rm ph on e D at io n ire ct or y
Optical Glass Panel 10mm thick
Exterior Locking Fastener
Bottom Enclosure
Leve
Secu
en
ato
Elev um
Aud G re
Optical Glass Panel
â&#x20AC;&#x2122;s R
Esca
th
nce
12 3-
4567 12 345 12 3- 67 4567
Map Graphics Printed on Duratrans (translucent substrate)
Glass Support Platform
LED Lights
Diffuser Panel 5mm thick and directly above LED light source Support Platform Constructed to support the compression and weight of glass panel
LED Lights
2
Section View
3
Plan View
47
Scale 1:5
47
Scale NTS
Bottom Enclosure Attached to base structure, tilted at viewing angle
Support Platform
41 CMA Tower Riyadh, Kingdom of Saudi Arabia
Table Map [TM] Measurements, Descriptions, and Construction Details
Front
Front
Internal support; drawing shows approximate location only; consult structural engineer
Bending angles: Rounding of edges are tolerable. Form edges at sharpest possible tolerance
Internal support
Open interior
Open interior
3mm stainless steel skin
2
Section Cut
4
Section Cut
49
Scale 1:3
49
Scale 1:3
Front
5
Front
49
Internal support
Internal support
4
49
3
49
Internal support; drawing shows approximate location only; consult structural engineer
2
49
Open interior
Open interior
1
Location of Section Cuts
3
Section Cut
5
Section Cut
49
Scale NTS
49
Scale 1:3
49
Scale 1:3
42 CMA Tower Riyadh, Kingdom of Saudi Arabia
Movable Stanchion [MS] Measurements, Descriptions, and Construction Details Measurements in millimeters
Fabrication Notes & Requirements 230
256
Meeting in session
Do Not Enter
5 33
A4 paper insert
A4 paper insert
Head base
1
53
Meeting in session
3
Plan View
50
Scale 1:15
Wheel Mechanism Use mechanism with the ability to lock wheels when stationary. Locking lever located at the bottom of the structure or at the base and shall be made accessible to operator. Covered wheels with padding to protect floor surfaces from damages or scuffs. Use wheels of neutral colors and position wheels inboard within structure for low visibility.
Do Not Enter
285
256
930
995
1140
Wheel
Base
230
10
1
Movable Stanchion
2
Right Side View
4
Footprint
50
Scale 1:15
50
Scale 1:15
50
Scale 1:15
Seams should be kept to a minimum and no open gaps of more than 1mm are acceptable. Structure should be symmetrical and structurally sound. Use additional structural reinforcement (internal and hidden from view) if deemed necessary from an engineering standpoint. Edges are to be beveled and smoothed-out, leaving no sharp edges that may cause injuries. If components are manufactured separately, the overall finish and color of material must be visually identical after assembly. Production of a full-scale, working prototype is HIGHLY RECOMMENDED for this sign type to test for structural durability, functionality, and aesthetic quality.
43 CMA Tower Riyadh, Kingdom of Saudi Arabia
Movable Stanchion [MS] Material Identification Material Identification Refer to Material Identification Section C A
A B B
C
A
1
Isometric for Material Identification
51
Scale NTS
Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish. Clear Acrylic Clear Acrylic serves as protective glass to paper insert. Must be optically clear without detracting from image quality. Bevel and finish all edges. Crystalline Facet Exposed to view behind acrylic panel. All films are laminated together and sandwiched between acrylic block and opaque white backing (see section of Crystalline Graphic Film for details). Exposed to view behind acrylic panel.
MAT
SS
MAT
CA
MAT
CA
MAT
CF
44 CMA Tower Riyadh, Kingdom of Saudi Arabia
Movable Stanchion [MS] Measurements, Descriptions, and Construction Details 16
75
20
Wheel 75
3mm exterior skin
Lever to activate wheel locking mechanism to back wheel; accessible to operator 25
70
16
40
Meeting in session
257
50
Head base
40
A4 paper insert Clearance from wheel 30
Lever to activate wheel locking mechanism to front wheel; accessible to operator
35
Do Not Enter Base plate
14
Overhang
10
210
10
115
1
Plan View
2
Bottom View
52
Scale 1:2
52
Scale 1:2
16
45 CMA Tower Riyadh, Kingdom of Saudi Arabia
Movable Stanchion [MS] Measurements, Descriptions, and Construction Details Return fold
10
Clear acrylic surface cover (polished with diamond cut finish)
Clear acrylic surface cover (clear polished finish)
Reveal cut 1 3
A4 insert
20
Metal plate (with reveal cut)
Clear acrylic
Fastener installs here Position of fastener
Crystalline graphic film
A4 insert
Fastener
Insert stopper, clear acrylic adhered to metal plate
Insert stopper
Metal plate (with reveal cut)
Head base
Clear acrylic
Crystalline graphic film
1 54
Head Base Composition â&#x20AC;&#x201D; Right Side View
2
Head Base Composition
Scale 1:2
54
Scale NTS
Head base
46 CMA Tower Riyadh, Kingdom of Saudi Arabia
Movable Stanchion [MS] Measurements, Descriptions, and Construction Details
109
109
105
Note: Allocate space at coverging and turning corners to accommodate for bending/folding of metal sheet
Surface
1
Surface
Surface
8
1 58
16
Surface
Surface
3
Surface
2
107
Front View
2
Scale 1:8
58
16
7
Surface
4
146
Surface
5
Surface
2
107
Note: Allocate space at coverging and turning corners to accommodate for bending/folding of metal sheet
Surface
4
123
107
Right Side View
3
Scale 1:8
58
Surface
6
16
Surface
6
107
8
146
16
Rear View
4
Left Side View
Scale 1:8
58
Scale 1:8
123
47 CMA Tower Riyadh, Kingdom of Saudi Arabia
Double-Sided Digital Display [DD] Measurements, Descriptions, and Construction Details Measurements in millimeters 1
Fabrication Notes & Requirements
63
1100 600
863
70â&#x20AC;? LED Monitor Portrait orientation with viewable area of 1545 x 863mm
1
2430
1545
62
Seams should be kept to a minimum and no open gaps of more than 1mm are acceptable. Structure should be symmetrical and structurally sound. Use additional structural reinforcement (internal and hidden from view) if necessary from an engineering standpoint. Exposed edges are to be beveled and smoothed-out, leaving no sharp edges that may cause injuries. If components are manufactured separately, the overall finish and color of material must be visually identical after assembly. Protective glass or any part of the structure should not detract from picture quailty of the LED monitors. Secure sign structure to ground using expansion bolts. Production of a full-scale, working prototype is HIGHLY RECOMMENDED for this sign type to test for structural durability, functionality, and aesthetic quality. Electronic and Digital Components AV consultant to provide LED monitor(s). Reference AV package for monitor and data/electrical requirements. Signage fabricator responsible for frame and structural detail. General LED monitor hardware specifications (for reference only): High Brightness, 24/7 rated, 1080p resolution, and international power. Adjustment to monitor made by using remote.
537
Crystalline Graphic See section on Crystalline Graphic Film. Backlit with internal LED illumination. 6000K white balance.
1
Double-Sided Digital Display
59
Scale 1:20
1360
2
Left Side View
59
Scale 1:20
48 CMA Tower Riyadh, Kingdom of Saudi Arabia
Double-Sided Digital Display [DD] Section Cuts and Details
600
Ventilation
Ventilation
Plan View Scale 1:15
51
1 60
111
Ventilation
432
600
537
1360
Opening for electrical and data feed
Opening for electrical and data feed 278
2
Bottom View
3
Bottom Detail
60
Scale 1:15
60
Scale 1:10
804
49 CMA Tower Riyadh, Kingdom of Saudi Arabia
Double-Sided Digital Display [DD] Material Identification
Etched and filled line 3mm width
Etched and filled line 3mm width
A
A
Material Identification Refer to Material Identification Section
A
B
B
B
A Etched and filled line 3mm width
Etched and filled line 3mm width
C
A
Identical configurations and specifications are identical on both sides of sign structure
1
Isometric View for Material Identification
61
Scale NTS
Structure Side (Left And Right) Stainless steel marine grade type 316 with satin, medium horizontal brush finish.
MAT
SS
MAT
SS
MAT
EG
MAT
CA
MAT
CF
MAT
GL
Faceted crystalline pattern to be etched and filled on stainless steel structure (see section of Faceted Crystalline Pattern for details).
E
D
Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish.
C
Crystalline Facet Internally illuminated (see section on Crystalline Facet for further information).
D Anti-Glare Optical Glass 5mm thick optical glass serves as protective glass to LED monitor. Must be optically clear without detracting from image quality. Bevel and finish all edges.
E
HD LED Monitor Two High-Definition 16:9 monitors of 70â&#x20AC;? screen size. Portrait orientation. Screens are positioned back-toback against each other allowing for viewing from front and back. Allow for adequate spacing in-between for heat to dissipate. Original bezel or frame of the monitors may have to be removed prior to monitor mounting.
50 CMA Tower Riyadh, Kingdom of Saudi Arabia
Double-Sided Digital Display [DD] Section View equal
Open Space
equal
Cabinet Body Formed from 3mm thick stainless steel
Air Circulation Open Space Located behind LED monitors for air to circulate and clearance for wires and cables
Clear Optical Protective Glass
Rubber Spacer To provide separation between glass and monitor
198
Monitor Brackets Custom formed brackets securing LED monitors to structure. Shape of bracket conforms to shape of the monitor. Do not block heat vents
HD LED Monitor A 198mm in thickness
equal
Tube Support Frame Main support for sign structure and expansion bolted to ground
175
Whisper Micro Fans
Z Clip (Side) Attach side panels to support frame (see section on Z Clips)
equal
Horizontal Beams Stainless steel beams for attachment of Whisper Fans and other accessories 198
HD LED Monitor B 198mm in thickness
Stainless Steel Panel (Left and Right Side) 3mm thick stainless steel panel with etched pattern
Monitor Brackets
Z Clips Attach side panels to central support (see section on Z Clips)
1
Section View
62
Scale 1:5
Clear Optical Protective Glass 5mm thick and non-glare. For protection of LED monitors from impact or touch
Rubber Spacer
Cabinet Body
NOTE: Use LED manufacturerâ&#x20AC;&#x2122;s mounting/electronic hardware whenever possible; modify hardware to use in sign
Section View
Scale 1:8 Clear Optical Protective Glass
Open space
Monitor Bracket Position to coordinate with configuration of monitor
Air Intake Gap Approx. 13mm wide; open to draw cool air to aid heat dissipation
Filter Foam Attached at the opening of air intake gap; hidden from view
Stainless Steel Bolt Attach monitor support tray to tube support frame
Monitor Support Tray
1
63 Open space
Open space
Fastener
140
equal
294
equal
140
Exterior Cabinet 3mm thick stainless steel
68
2
Exterior Cabinet 3mm thick stainless steel
Whisper Micro Fan (Bottom Row)
Monitor Bracket
Clear Optical Protective Glass
Z Clip Side B Attached to horizontal beam (on both sides)
Z Clip Side A Attached to monitor unit (on both sides)
LED Monitor Unit Approx. 198mm thick
LED Monitor Unit Approx. 198mm thick
Tube Support Frame Approx. 198mm thick
Spacers Occupies space between monitor and optical glass
Whisper Micro Fan Draw heat upwards to exiting heat vent
Top End Cap Panel 3mm stainless steel with cut through heat vent. Attach with mechanical fasteners
51
Double-Sided Digital Display [DD] CMA Tower Riyadh, Kingdom of Saudi Arabia
Section View
2430
52 CMA Tower Riyadh, Kingdom of Saudi Arabia
Double-Sided Digital Display [DD] Monitor on Support Frame
Tube Support Frame
LED Monitor Unit Monitor Brackets
Monitor Brackets LED Monitor Unit
Monitor exposed to view; viewable area LED Monitor Unit
Monitor Brackets Support Tray Additional support platform for monitor to rest on
Space for power supply, transformers
Crystalline Facet Internally illuminated
1 64
Composite — Isometric View
2
Scale NTS
64
Exterior Cabinet — Isometric View
3
Interior Frame Structure — Isometric View
Scale NTS
64
Scale NTS
Space for power supply, transformers, etc.
53 CMA Tower Riyadh, Kingdom of Saudi Arabia
Double-Sided Digital Display [DD] Monitor Mounting Details Fasteners Tube Support Frame Provide main integral support for entire structure
Fastener Monitor Bracket Detachable with fasteners; mounted to tube support frame
Tube Support Frame
Z Clip One component attached to frame and mechanically locks to the Z Clip at the rear of monitor
198
Length to accommodate thickness of LED monitor (allow for cushion lining)
Viewing Direction
1 65
Internal Support Only â&#x20AC;&#x201D; Isometric View
2
Scale NTS
65
Isometric View of Frame and Monitor Brackets
3
Monitor Bracket Detail â&#x20AC;&#x201D; Plan View
Scale NTS
65
Scale 1:3
Protective Lining Cushion at contact points of monitor and monitor bracket
Monitor Bracket
54 CMA Tower Riyadh, Kingdom of Saudi Arabia
Double-Sided Digital Display [DD] Heat Dissipation within Structure
Whisper Micro Fans
Heat Path
Mount to horizontal beam and detachable for ease of replacement; silent motor to reduce mechanical noises
Internal Air Circulation and Heat Dissipation Heat dissipation path located in the open spaces in between the rear of the monitor units where most of the heat is generated from the LED monitor units. The flow is facilitated by eight electronic Micro Fans distributed in three rows (top, middle and bottom). Fans at the lower portion help guide the heated air upwards, and the fans at the very top will provide the final push for heated air to exit out into the exterior of the structure through the top vents. Allow open gaps at bottom underneath the monitors for drawing in cool exterior air. Fans should be made detachable for replacement and maintenance purposes. All loose wires (from monitors, fans, etc.) must be attached to support frame for organization.
Heated air exits from open vents located at the top of sign structure
Top Row (2 fans)
Horizontal Beam Heat Path
Heat dissipation path Whisper Micro Fans
Fans draw heated air upwards and away from LED monitor units
Whisper Micro Fans Heat vents
Middle Row (3 fans)
Whisper Micro Fans
Heat Path
Heat dissipation path located in the open spaces in between the rear of the monitor units
Electrical wires
Bottom Row (3 fans)
Open gaps in exterior cabinet allows fans to draw cool air into dissipation path
Internal support frame
Exterior cabinet
1
Internal Support Only — Isometric View
2
Internal Support Only — Front View
3
Internal Support Only — Isometric View
66
Scale NTS
66
Scale NTS
66
Scale NTS
55 CMA Tower Riyadh, Kingdom of Saudi Arabia
Double-Sided Digital Display [DD] Details of Access Panels
Fastener Mechanical fasteners compress all components to frame
Mechanical Grip Inserted into grip catch on both sides. Secure and lock exterior cabinet to support frame. Use allen wrench to tighten
Top Access Panel
Grip Catch Catches mechanical grip and attached to support frame; tighten connection using allen wrench
Tab Welded to side access panel
Surface on support frame for installation of mechanical fasteners
Fastener Side Access Panel
Z Clip installation on this surface (see section on Z Clips)
Z Clip
Top Access Panel Open heat vent for exiting air
Grip Catch Catches mechanical grip and attached to exterior cabinet; tighten connection using allen wrench Tab Welded to side panel as a surface to receive mechanical fasteners above
Side Access Panel Attach to support frame using Z Clips. Welded tab at top for mechanical fasteners Z Clips installation on this surface (see section on Z Clips)
Angled side access panel
Note: Use identical details on both sides of sign structure
Open space Secure bottom of exterior cabinet to the lower structure or to ground plate
Support Frame
1
Top Panel and Z Clip Details
2
Isometric
67
Scale NTS
67
Scale NTS
56 CMA Tower Riyadh, Kingdom of Saudi Arabia
Double-Sided Digital Display [DD] Details of Crystalline Facet
equal
equal
LED Light Source
Support Frame Positioning Tab
Fastener
Attach crystalline graphic facet to sign structure
Upper Acryic Bracket
Cabinet Body
3mm thick stainless steel
Filter Foam
Clear Acrylic Block B
Cut from one continuous block of acrylic 15mm thick (repeat detail at opposite side) 88
Use fasteners to attach to bottom of sign structure
Viewing Portion
Direction of Light
Crystalline Graphic Film
Direction of Light
(repeat detail at opposite side)
Clear Acrylic Block A
Cut from one continuous block of acrylic 25mm thick (repeat detail at opposite side)
Exterior Cabinet Body
Positioning Tab
Detachable and adjustable to tightly secure acrylic components and graphic film
Crystalline Graphic Facet
Exterior Cabinet Body
Fastener
Install flush at exposed end
Open Space
Location in relation to the sign structure
Air Intake Gap
Leave open to exterior
1 68
Crystalline Graphic Facet
2
Section View
Scale 1:15
68
Scale 1:3
Lower Acryic Bracket 3mm thick stainless steel
Air Intake Gap
Leave open to exterior
57 CMA Tower Riyadh, Kingdom of Saudi Arabia
Double-Sided Digital Display [DD] Support Frame
Location of support structure within exterior cabinet (shaded in blue)
Monitor Bracket
Monitor Bracket
Tube Support Frame
LED Monitor
Z Clip Attached to horizontal beam
Viewing Direction
Monitor Bracket
Support Tray Lower Support Frame Addtional support directly below of monitor Base Plate and Bolts Plate welded to structure and firmly attached to ground
1
Tube Support Frame
2
View Without Exterior Skin and LED Monitor
3
View Without Exterior Skin and LED Monitor â&#x20AC;&#x201D; Right Side View
70
Scale 1:20
70
Scale 1:20
70
Scale 1:20
Z Clip (to monitor) Tube Support Frame
58 CMA Tower Riyadh, Kingdom of Saudi Arabia
Single-Sided Digital Display [SS] Measurements, Descriptions, and Construction Details Measurements in millimeters 1
Fabrication Notes & Requirements
75
1100
365
863
70â&#x20AC;? LED Monitor Portrait orientation with viewable size at 1545 x 863mm
1
2430
1545
76
Electronic and Digital Components AV consultant to provide LED monitor(s). Reference AV package for monitor and data/electrical requirements. Signage fabricator responsible for frame and structural detail. General LED monitor hardware specifications (for reference only): High Brightness, 24/7 rated, 1080p resolution, and international power. Adjustment to monitor made by using remote.
3
72
Crystalline Graphic See section on Crystalline Graphic Film. Backlit with internal LED illumination. 6000K white balance.
537
1 71
Single-Sided Digital Display Scale 1:20
Seams should be kept to a minimum and no open gaps of more than 1mm are acceptable. Structure should be symmetrical and structurally sound. Use additional structural reinforcement (internal and hidden from view) if necessary from an engineering standpoint. Exposed edges are to be beveled and smoothed-out; leaving no sharp edges that may cause injuries. If components are manufactured separately, the overall finish and color of material must be visually identical after assembly. Protective glass or any part of the structure should not detract from picture quailty of the LED monitors. Secure sign structure to ground using expansion bolts. Production of a full-scale, working prototype is HIGHLY RECOMMENDED for this sign type to test for structural durability, functionality, and aesthetic quality.
1360
2
Left Side View
71
Scale 1:20
59 CMA Tower Riyadh, Kingdom of Saudi Arabia
Single-Sided Digital Display [SS] Material Identification Material Identification Refer to Material Identification Section
Heat vents A
A
A
B
Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish. Structure Side (Left And Right) Stainless steel marine grade type 316 with satin, medium horizontal brush finish. Etched pattern (see section on Faceted Crystalline Pattern).
MAT
SS
MAT
SS
MAT
CA
MAT
GL
MAT
TA
E C
B A
B
D Anti-Glare Optical Glass 5mm thick optical glass serves as protective glass to LED monitor. Must be optically clear without detracting from image quality. Bevel and finish all edges.
A
E
C
A
A
A
1 73
Crystalline Facet Internally illuminated (see section on Crystalline Facet for further information).
Front Isometric for Material Identification
2
Rear Isometric for Material Identification
Scale NTS
73
Scale NTS
HD LED Monitor Two High-Definition 16:9 monitors of approximately 62â&#x20AC;? screen size. Oriented vertically. Slightly smaller screens are allowed (no smaller than 55â&#x20AC;?) but adjust bezel around screen proportionally. Screens are positioned back-toback against each other allowing for viewing from the front or back. Allow for adequate spacing between the two monitors for heat to dissipate. Original bezel or frame of the monitors may have to be removed prior to monitor mounting.
MAT
CF
135
67
2mm width
Rear View â&#x20AC;&#x201D; Pattern of Heat Ventilations
Scale 1:10 100 1685
1
74 135
10mm diameter
2mm width
Heat Vents
Rear Access Panel Fasteners
125
Fastens to structure and detachable to access LED lights; panel and fasteners to match exterior skin finish and install flush to surface (outlined in blue)
67
90
Rear Access Panel
Heat Vents
440
60
Single-Sided Digital Display [SS] CMA Tower Riyadh, Kingdom of Saudi Arabia
Measurements, Descriptions, and Construction Details
61 CMA Tower Riyadh, Kingdom of Saudi Arabia
Single-Sided Digital Display [SS] Measurements, Descriptions, and Construction Details
Rear Access Panel
Clear Acrylic Block B
Cut from one continuous block of acrylic 15mm thick (repeat detail at opposite side)
Detach to access LED lights
Crystalline Graphic Film
Accessible from the rear of sign structure. Install flush to surface
Fastener
(repeat detail at opposite side)
Clear Acrylic Block A
Cut from one continuous block of acrylic 25mm thick (repeat detail at opposite side)
Fastener
Filter Foam
88
Exterior Cabinet Body
1
Leave open to exterior
Fastens to structure and detachable to access LED lights; panel and fasteners to match exterior skin finish and install flush to surface
Reference details of sign type DD
77
Air Intake Gap
Rear Access Panel
Folded Lip
Isometric
2
Scale NTS
77
Viewing Portion
Rear Isometric View
3
Section View
Scale NTS
77
Scale 1:3
Direction of Light
Positioning Tab
Detachable and adjustable to tightly secure acrylic components and graphic film
Open Space
62 CMA Tower Riyadh, Kingdom of Saudi Arabia
Perforations for Audio Devices Optional Details for Sign Type DD & DS
75 75
310
2
80
Upper Audio Perforations (2) In the shape of a trapezoid of 310mm tall x 75mm wide at the bottom then tapers down to 35mm at the top. The shape to follow the contours of the structure while spacing 15mm away from perforations to edges. Mirror details at opposite side. 210
310 75
210
75
3
80
Lower Audio Perforations (2) In the shape of a parallelogram of 210mm wide x 75mm high. Mirror details at opposite side.
1
Front View â&#x20AC;&#x201D; Locations of Audio Perforations
2
Detail of Upper Audio Perforations
3
Detail of Lower Audio Perforations
80
Scale 1:15
80
Scale 1:5
80
Scale 1:5
63 CMA Tower Riyadh, Kingdom of Saudi Arabia
Single-Sided Freestanding Map Directory [FM] Measurements, Descriptions, and Construction Details 1
89
490
Measurements in millimeters
490
150
Fabrication Notes & Requirements
1
Seams should be kept to a minimum and no open gaps of more than 1mm are acceptable. Structure should be symmetrical and structurally sound. Use additional structural reinforcement (internal and hidden from view) if necessary from an engineering standpoint. Edges are to be beveled and smoothed-out; leaving no sharp edges that may cause injuries. If components are manufactured separately, the overall finish and color of material must be visually identical after assembly. Secure sign structure to ground using expansion bolts. Production of a full-scale, working prototype is HIGHLY RECOMMENDED for this sign type to test for structural durability, functionality, and aesthetic quality.
165
90
84
LE VEL 1
840
North Entrance
2 You Are Here
South Entrance 1 3
Viewing Direction
Menâ&#x20AC;&#x2122;s Restroom Escalator Information Elevator to CMA Levels Elevator to Levels 00-00 Elevator to Levels 00-00 Elevator to Parking Podium Levels Elevator
1
Legend Here
4
Legend Here
7
Green Room
2
Legend Here
5
Legend Here
8
VIP Lounge
3
Legend Here
6
Legend Here
9
2045
2045
Security Check
Auditorium
Quick Reference Security Desk
123-4567
Tower Information
123-4567 Telephone Directory
123-4567
Crystalline Graphic See section on Crystalline Graphic Film. Backlit with internal LED illumination. 6000K white balance. Backlit Display Use low heat light sources such as LED. 6000K white balance. Evenly distribute light without hot or dead spots on the display. Output map graphics at high resolution on Duratrans substrate.
55
55
Base skirt
215
620
620
350
1
Front View
2
Side View
3
Rear View
81
Scale 1:15
81
Scale 1:15
81
Scale 1:15
64 CMA Tower Riyadh, Kingdom of Saudi Arabia
Single-Sided Freestanding Map Directory [FM] Material Identification Material Identification Refer to Material Identification Section
F
A
A
L VE
LE
1
B
B
2
Are
He
C
h ut ance So Entr
re
3
Me
nâ&#x20AC;&#x2122;s
Re
str
Esc
1
Infor
Ele Ele Ele
vat
vat vat
or
Po
to
or
to
or
Ele diu
Le
or
Leve Se
oo
ala
ma
ls 00
-00
vat
y Ch
4
dit
ee
VIP
or ium
n Ro Lo
12 en
He He He
nd
He He
re
D
C
8
re 9
re
12
3-4
56
7
5 6
re 3-4
56
7
Te
lep
ho
ne
Dir
ect
3-4
56
7
To
we
r Inf
orm
ati
MAT
DO
MAT
GL
MAT
SS
MAT
CA
MAT
EG
MAT
CF
eck
re
re
12
3
ge
fer
nd
gend
nd
Lege
SS
ng
ory
2
om
un
nd
Lege Le
1
Au Gr
Lege
Lege
He
MAT
or
7
nd Lege
SS
-00
Parki
ls Ele
curit
n
vels
00 vels
to
m
tor
tio
A Le
Leve
vat
m
CM
to
Structure Sides and Rear Stainless steel marine grade type 316 with satin, medium horizontal brush finish.
MAT
Faceted crystalline pattern to be etched and filled on stainless steel structure (see section of Faceted Crystalline Pattern for details).
th ance NEntror
You
Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish.
on
ce
Digital Output High resolution, high quality digital map artwork on Duratrans substrate.
Re sk ick De Qu ity cur Se
D Anti-Glare Optical Glass 5mm thick optical glass serves as protective glass to digital output. Must be optically clear without detracting from image quality. Bevel and finish all edges. E
F
E
1
Isometric for Material Identification
82
Scale NTS
D
Base Skirt Stainless steel marine grade type 316 with satin, medium horizontal brush finish. Transparent coating to protect from scuffs and scratches. Crystalline Facet Internally illuminated (see section on Crystalline Facet for further information).
65 CMA Tower Riyadh, Kingdom of Saudi Arabia
Single-Sided Freestanding Map Directory [FM] Access Panels for Service and Maintenence
Fastener
Acrylic Blocks
Fasteners install from top and lock side access panel in place
LED Components
Fastener
Fasteners install from top and lock side access panel in place
LED Cabinet Door
Acrylic Block
(shaded in gray lines)
Fastener
Fasteners install from top and lock side access panel in place
LE
Nor Entr
VE
3mm thick
Open space
Open space
L1
LED Door
Secured by fasteners installed from top and bottom. Act to hold acrylic pieces in position. Remove to access LED. Identical detail at opposite side
th
ance
1
You
3
Are
Her
e
So
ut anceh
Entr
Me
nâ&#x20AC;&#x2122;s
Res
tro
Esc Ele
Au
Ele
dit
een
VIP
ori
Ro
Lo
um
Ele
1
vat
vat vat
om
ung
Info or
or
Pod
to
Leg
ick Sec Refere urit y De nce sk
Leg Leg 123
-45
end end end
He He He
Tow
er
Info
rma
Lev or
Lev
els
or
atio
0000-
Par
Ele
urit
4
om
alat
rm
A Lev
els
to
els
Sec
re
n
els 00 00
kin
vat
y Ch
g
or
eck
re 5
re 6
67
CM
Lev
vat
ium
3
Qu
to
to
or
Ele
2
e
Welded to side access panel; tab used for installation of fastener
Side Access Panel
2
Gr
Tab
Leg Leg
tion
Leg 123
-45
67
Tel
end end end
He He He
re 7
re 8
re 9
eph
one
Dir
ect
ory
123
-45
67
Side Access Panel
Side Access Panel
On both sides of structure
Fastener
Installs from underneath platform plate and through the LED cabinet door
Welded to tube support frame
Platform
For the primary support for the LED and acrylic components
Side Access Panel 3mm thick
Open space
Z Clip
This component attached to side access panel
Tube Support Frame
Serves as primary support for structure. Platform is welded to frame for support Open space
Tube Support Frame
Serves as primary support for structure. Platform is welded to frame for support. This surface used to attach Z Clips
2
Detail View of Fastener
2
Front Interior View
85
Scale NTS
85
Scale 1:3
Tube Support Frame
Z Clip
This component attached to support frame
66 CMA Tower Riyadh, Kingdom of Saudi Arabia
Acrylic Crystalline Components Sign Type FM
Acrylic Crystalline Component
220
135
40
220
50
The acrylic used shall be clear and without any hints of color cast or frosting. Diamond polish all surfaces for a clear, glossy finish allowing light to pass through. The color and graphic comes from the crystalline graphic film (see section on Crystalline Graphic Film) and is sandwiched in between two pieces of clear acrylic. Both acrylic pieces and graphic film to be cut precisely for an exact fit when fully assembled. Secure all three components tightly to ensure graphic film stays flat without bending. Use metal brackets to compress and fasten all pieces together. Install LED light source behind the acrylic for backlighting effect.
Crystalline Graphic Film Stainless steel structure
Acrylic B Diffuser backer (cut to shape)
Unexposed area of acrylic; secured within structure (shaded)
2
Front View
86
Scale 1:4
Unexposed area of acrylic; secured within structure (shaded)
Exposed area of acrylic (un-shaded)
Crystalline Graphic Film
Viewing Direction
Acrylic A (shaped and formed)
Acrylic B Diffuser backer
34
Compress and fasten pieces tightly
Acrylic A
Viewing Direction
1 86
Isometric View
3
Plan View
Scale NTS
86
Scale 1:4
67 CMA Tower Riyadh, Kingdom of Saudi Arabia
Acrylic Crystalline Components Sign Type FM
Stainless Steel Cover A 3mm thick stainless steel panel, cut and formed to follow the contour of the crown, is used to cover the acrylic, graphic film, and LED lights. The cover plate to be fasten by two 10mm diameter fasteners at opposite ends. Consider using weather sealant (to keep debris out) on the surface that comes into contact with acrylic. Detach cover plate to service LED. Match color and finish to structure.
10mm fastener Cover plate Crystalline acrylic (exposed)
LED lights
Acrylic
1 88
Internal View
2
Composite View
Scale NTS
88
Scale NTS
1 Section View
89 Scale 1:8 840
Base Plate and Expansion Bolts Welded to support frame and attached to ground using expansion bolts
Fastener For attaching exterior cabinet to base skirt
Exterior Cabinet 3mm stainless steel
Tube Support Frame
Light Box Support Bracket Install at the lower portion of lightbox. Resting platform for light box above
Viewing Direction
Open space
Base Skirt Stainless steel protective base
Open space
Exterior Cabinet 3mm stainless steel
Open space
Map Graphic Light Box Approx. 80mm thick
Light Box Bracket Installed at top of light box; holding light box firmly in place. Attached to tube support frame
Platform For the primary support for the LED and acrylic componets
Acrylic Components
LED Lights
68
Single-Sided Freestanding Map Directory [FM] CMA Tower Riyadh, Kingdom of Saudi Arabia
Section View
69 CMA Tower Riyadh, Kingdom of Saudi Arabia
Double-Sided Freestanding Map Directory [FD] Measurements, Descriptions, and Construction Details 1
93
Measurements in millimeters
490 245 1
165
90
91
LE VEL 1
LE VEL 1
North Entrance
840
North Entrance
2 You Are Here
South Entrance
2 You Are Here
South Entrance
1
1 3
3
Men’s Restroom
Men’s Restroom
Escalator
Escalator
Information
Information
Elevator to CMA Levels
Elevator to CMA Levels
Elevator to Levels 00-00
Elevator to Levels 00-00
Elevator to Levels 00-00
Elevator to Levels 00-00
Elevator to Parking
Elevator to Parking
Podium Levels Elevator
Podium Levels Elevator
Auditorium
1
Legend Here
4
Legend Here
7
Green Room
2
Legend Here
5
Legend Here
8
VIP Lounge
3
Legend Here
6
Legend Here
9
Security Check
2045
2045
Security Check
Quick Reference Security Desk
123-4567
Tower Information
123-4567 Telephone Directory
Auditorium
1
Legend Here
4
Legend Here
7
Green Room
2
Legend Here
5
Legend Here
8
VIP Lounge
3
Legend Here
6
Legend Here
9
Fabrication Notes & Requirements Seams should be kept to a minimum and no open gaps of more than 1mm are acceptable. Structure should be symmetrical and structurally sound. Use additional structural reinforcement (internal and hidden from view) if necessary from an engineering standpoint. Edges are to be beveled and smoothed-out; leaving no sharp edges that may cause injuries. If components are manufactured separately, the overall finish and color of material must be visually identical after assembly. Secure sign structure to ground using expansion bolts. Production of a full-scale, working prototype is HIGHLY RECOMMENDED for this sign type to test for structural durability, functionality, and aesthetic quality.
Quick Reference
123-4567
Security Desk
123-4567
Tower Information
123-4567 Telephone Directory
123-4567
Crystalline Graphic See section on Crystalline Graphic Film. Backlit with internal LED illumination. 6000K white balance.
434
Note: This is a doubled-sided structure; identical on both sides
55
55
Base skirt
620
1
Side A — Front View
2
Side View
3
Side B — Front View
90
Scale 1:15
90
Scale 1:15
90
Scale 1:15
Backlit Display Use low heat light sources such as LED. 6000K white balance. Evenly distribute light without hot or dead spots on the display. Output map graphics at high resolution on Duratrans substrate.
70 CMA Tower Riyadh, Kingdom of Saudi Arabia
Double-Sided Freestanding Map Directory [FD] Material Identification Material Identification Refer to Material Identification Section
F
A
A
A VE
LE
LE
Nor Ent
ran
VE
L1
th
You
Yo
3
u Ar
e He
Are
He
ut h
ance So Entr
re
re
So Ent
2
3
uth
ran
Me
nâ&#x20AC;&#x2122;s
Infor
Ele Ele nâ&#x20AC;&#x2122;s
Re
str
Esca Ele
Au
Ele
dit
ee
VI P
or
ium
n Ro Lo
Ele
1
vato
vato vato
om
un
Po
diu
3 Qu Se
Le
ick
cu
Inf r to
r to
Re fer en rit y De ce sk
Le Le 12
3-4
56
7
ge ge ge
nd nd nd
He He
we
r Inf
or
ma
He
tio
Le
vato Le
rit
Po
r
4
Lege Le Le Le 3-4
56
7
Te
ge ge ge
nd nd nd
Lege He He He
re 7
ho
ne
8
Au
re
Gr Di
rec
tor
Lege
1
re
9 lep
Leve
vat
m
or
Leve Se
curit
dit
ee
VIP
or ium
n Ro Lo
y Ch
12
y
12
3-4
56
en
He He He
Lege
nd
Lege
nd
He He He
re
3-4
56
7
To
we
r Inf
orm
ati
3-4
56
7
Te
lep
ho
ne
Dir
ect
C
eck
re 8
re 9
re 3-4
56
7
ory
Digital Output High resolution, high quality digital map artwork on Duratrans substrate.
E
Scale NTS
GL
MAT
SS
MAT
CA
MAT
CF
Re sk ick De Qu ity cur Se
7
F
Isometric for Material Identification
MAT
ce
E
1
DO
on
D Anti-Glare Optical Glass 5mm thick optical glass serves as protective glass to digital output. Must be optically clear without detracting from image quality. Bevel and finish all edges.
92
MAT
n
5 6
EG
ng
re re
MAT
or
12
12
3
ge
fer
nd nd
nd
SS
-00
vat
2
om
un
nd
Lege
MAT
-00
Parki
ls Ele
Structure Side (Left And Right) Stainless steel marine grade type 316 with satin, medium horizontal brush finish.
vels
ls 00
to
m
tor
tio
00
7
k
5
12
to
or
diu
D
ng
ec
re
n
to
or
oo
ala
ma
A Le
ls Leve
n
-0 0
vato
y Ch
vat
CM
to
ls
-0 0
rki
vat
or
Ele
or
ve
ls 00 Pa
Ele
vat
m
tio
Le
ls 00
ls Ele
cu
4
lat
ma
A
r to
ve
Se
re
or
ve ve
oo
re
6 To
m
CM
Le
r to
Ele
2
ge
str
Esc
1
Me
Re
ce
SS
Faceted crystalline pattern to be etched and filled on stainless steel structure (see section of Faceted Crystalline Pattern for details).
th ance NEntror
1
Gr
B
B
C
MAT
L1
ce
2
Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish.
Base Skirt Stainless steel marine grade type 316 with satin, medium horizontal brush finish. Transparent coating to protect from scuffs and scratches. Crystalline Facet Internally illuminated (see section on Crystalline Facet for further information).
Section View
Scale 1:8 Base Plate and Expansion Bolts Welded to support frame and attached to ground using expansion bolts
Fastener For attaching exterior cabinet to base skirt
Open space
Exterior Cabinet 3mm stainless steel
Tube Support Frame
Light Box Support Bracket Install at the lower portion of light box. Resting platform for light box above
Viewing Direction
Light Box Bracket
Open space
840
1
93 Acrylic Components
1
FS
eq.
eq.
Expansion Bolts Consult structural engineer for quantity and specifications
Base Skirt Stainless steel protective base
Exterior Cabinet 3mm stainless steel
Open space
Viewing Direction
Map Graphic Light Box â&#x20AC;&#x201D; Side B Approx. 80mm thick
Map Graphic Light Boxâ&#x20AC;&#x201D; Side A Approx. 80mm thick
Light Box Bracket Installed at top of light box; holding light box firmly in place. Attached to tube support frame
Platform For the primary support for the LED and acrylic componets
Acrylic Components
LED Lights
71
Double-Sided Freestanding Map Directory [FD] CMA Tower Riyadh, Kingdom of Saudi Arabia
Section View
72 CMA Tower Riyadh, Kingdom of Saudi Arabia
Double-Sided Freestanding Map Directory [FD] Details of Access Panel LED Components
Fastener
Fasteners install from top and lock side access panel in place
Acrylic Blocks Fastener
LED Cabinet Door
Fasteners install from top and lock side access panel in place
Fastener
Acrylic Block
(shaded in gray lines)
Fasteners install from top and lock side access panel in place
Tab
Welded to side access panel; tab use for installation of fastener
Side Access Panel 3mm thick
LE
Nor Entr
VE
Open space
Open space
L1
LED Door
th
ance
Secured by fasteners installed from top and bottom. Act to hold acrylic pieces in position. Remove to access LED. Identical detail at opposite side
2
1
You
3
Are
Her
e
So
ut anceh
Entr
Me
nâ&#x20AC;&#x2122;s
Res
tro
Esc Ele
Au
Side Access Panel
Gr
Ele
dit
een
VIP
ori
Ro
Lo
um
Ele
1
vat
vat vat
om
ung
e
Info or
or
Pod
to
Leg
ick Sec Refere urit y De nce sk
Leg Leg 123
-45
end
ium
end end
He He He
Tow
er
Info
rma
or
Lev
re
els
to
els
or
atio
0000-
Par
Ele
urit
4
om
alat
rm
A Lev
els
n
els 00 00
kin
vat
y Ch
g
or
eck
re 5
re Leg Leg
tion
Leg 123
On both sides of structure
Lev
Sec
6
67
CM
Lev
vat
3
Qu
to
to
or
Ele
2
-45
67
Tel
end end end
He He He
re 7
re 8
re 9
eph
one
Dir
ect
ory
123
-45
67
Fastener
Side Access Panel
Install from underneath platform plate and through the LED cabinet door
Welded to tube support frame
Platform
For the primary support for the LED and acrylic components
Side Access Panel 3mm thick
Open space
Z Clip
This component attached to side access panel
Tube Support Frame
Serves as primary support for structure. Platform is welded to frame for support Open space
Tube Support Frame
Serves as primary support for structure. Platform is welded to frame for support. This surface for attachment of Z Clips
1
Isometric View
2
Front Interior View
94
Scale NTS
94
Scale 1:3
Tube Support Frame
Z Clip
This component attached to support frame
73 CMA Tower Riyadh, Kingdom of Saudi Arabia
Double-Sided Freestanding Map Directory [FD] Details of Map Graphics Light Box 2
15
435
5
For the operation of hinged door
Movable for easy access for maintenance of interior components
80
Hinged Door
Light Box Cabinet
5
Folded Bezel
Hidden from view
Position Bracket
Extent of glass; hidden from view
Light Box Cabinet
Secure glass panels and graphic in firm position; cushion at contact points with glass
5
30
Lock
Hinged Door
95
Container of components
On/Off Switch
(accessible from top)
Viewing Direction
LED Lights Area exposed to view
Diffuser Panel
Approx. 6mm thick. Distribute light evenly below graphic print. Avoid hot spots or shadows from appearing
3
Plan View â&#x20AC;&#x201D; Light Box Only
95
Scale 1:6 On/Off Switch
(accessible from top)
Light Box Cabinet
Light Box Cabinet Hidden from view
840
840
Graphic Print
Hinged Door
Printed on translucent substrate; Duratrans printing
Clear Optical Glass Panel
Movable for easy access for maintenance of interior components; heat vent perforated on door (illustration shown with door open)
LE
Approx. 6mm thick. Optically clear for graphic below to show clearly
No Ent
VE
L1
rt h
ran
ce
2
Folded Bezel
Part of the window of the cabinet works to hold glass panels in place; cushion at contact points with glass
Perforated heat vents pattern
1
Diffuser Panel
Yo
3
u Ar
e He
re
So Ent
en
riu
Ro
Lo
Q uic Se
Position Bracket
5
â&#x20AC;&#x2122;s Re
str
Esca
G re
Ele
di to
Ele
m 1
va to
va to va to
om
un
cu
Po
Le k Re fer en rit y De ce sk
Le Le 12
Secure glass panels and graphic in firm position; cushion at contact points with glass
Inf r to
r to
diu
3- 45
ge ge ge
nd nd nd
To
we
r Inf
or
m at
e
H er
e
H er
e
6
Le Le Le
30
1
Front Interior View
2
Section View
4
Isometric View
95
Scale 1:6
95
Scale 1:6
95
Scale NTS
Le
ve
ls 00
r to
ve
Pa
ls Ele
curit
m
or
ve
ls 00
n
ls
-0 0 -0 0
rk ing
vato
y Ch
r
eck
5
12
Duratrans Print
va to
oo lat
atio
A Le
ve
4
ion
Clear Optical Glass Panel
Le
Se
H er
67
m
or m
CM
Le
r to
Ele
2
ge 3
Hidden from view
ce
M en
Ele
Au
VI P
Folded Bezel
uth
ran
3- 45
67
Te
lep
ho
ne
Di
ge ge ge
nd nd nd
re ct
or
H er
e
H er
e
H er
e
7 8 9
y
12
3- 45
67
LED Lights
74 CMA Tower Riyadh, Kingdom of Saudi Arabia
Acrylic Crystalline Component Sign Type FD
Acrylic Crystalline Component
220
135
40
220
50
The acrylic used shall be clear and without any hints of color cast or frosting. Diamond polish all surfaces for a clear, glossy finish allowing light to pass through. The color and graphic comes from the crystalline graphic film (see section on Crystalline Graphic Film) and is sandwiched in between two pieces of clear acrylic. Both acrylic pieces and graphic film to be cut precisely for an exact fit when fully assembled. Secure all three components tightly to ensure graphic film stays flat without bending. Use metal brackets to compress and fasten all pieces together. Install LED light source behind the acrylic for backlighting effect.
Crystalline Graphic Film Stainless steel structure
Acrylic B Diffuser backer (cut to shape)
Unexposed area of acrylic; secured within structure (shaded)
2
Front View
86
Scale 1:4
Unexposed area of acrylic; secured within structure (shaded)
Exposed area of acrylic (un-shaded)
Crystalline Graphic Film
Viewing Direction
Acrylic A (shaped and formed)
Acrylic B Diffuser backer
34
Compress and fasten pieces tightly
Acrylic A
Viewing Direction
1
Isometric View
3
Plan View
86
Scale NTS
86
Scale 1:4
75 CMA Tower Riyadh, Kingdom of Saudi Arabia
Acrylic Crystalline Component Sign Type FD Unexposed portion of acrylic (shaded)
Unexposed portion of acrylic (shaded)
Positioning Acrylic Crystalline within Sign Structure
Mirrored construction details
The majority of the acrylic is contained within the structure for protection and only a small portion is exposed for viewing (exposed portion shown in color). Use adequate lighting to backlight the exposed portion but the graphic film should cover the entirety of the acrylic, including the unexposed portion hidden from view.
Mirrored construction details eq.
2
Plan View
97
Scale 1:5
50
135
40
eq.
Acrylic A
Acrylic A
Crystalline Graphic Film
Crystalline Graphic Film
Acrylic B
Unexposed portion of acrylic (shaded)
Acrylic B
102°
Viewing Direction
Viewing Direction
Opening for Map LED light source
1
Front View
3
Side View of Acrylic Components
97
Scale 1:4
97
Scale 1:4
76 CMA Tower Riyadh, Kingdom of Saudi Arabia
Z Clips Details of Interlocking Clips for Side and Access Panels
Fasteners
Install flush; secures all components together; quantity TBD per sign type; consult construction engineer.
End Cap Panel
Tab extends underneath end cap
Side tab extends and aligns with frame
Support Frame
Welded
Fastener
Width of supporting frame Side tabs
Z Clip
(Component B) Mounts to side panel or access panels.
Z Clip
(Component B) Mounts to side panel or access panels.
Z Clip
(Component A) Mounts to support frame of sign structure.
Adjust width of Z Clips to fit mounting surface
End cap panel
Side tab Z Clip
(Component B) Mounts to side panel or access panels.
Access/detachable panel
Side panel
Z Clip
Detachable Panel
(Component A) Mounts to support frame of sign structure.
Support frame
Z Clip
(Component B)
Z Clip Welded
(Component A) Mounts to support frame of sign structure.
Z Clip
(Component A)
Support frame/ mounting surface
1
Rear Access Panel
2
Typical Z Clip Side View
3
Z Clip Isometric View
4
Section View
98
Scale NTS
98
Scale NTS
98
Scale NTS
98
Scale NTS
77 CMA Tower Riyadh, Kingdom of Saudi Arabia
Overhead Directional [OD] Measurements, Descriptions, and Construction Details Measurements in millimeters
Fabrication Notes & Requirements 1760
120
39
225
1
Plan View
FS
Scale 1:10
Suspension cable
112
112
2
119
FS
5
Actual seam created by legend plate
Crystalline Graphic See section on Crystalline Graphic Film. Allow ambient and natural lighting from environment to enter structure to illuminate the acrylic components.
175
300
Main Lobby
Auditorium
Structure should be symmetrical and structurally sound. Use additional structural reinforcement (internal and hidden from view) if necessary from an engineering standpoint. Edges are to be beveled and smoothed-out. Sign should be seamless with no visible fasteners except at plan view. If components are manufactured separately, the overall finish and color of material must be visually identical after assembly. Secure sign structure to ceiling using suspension cable. Production of a full-scale, working prototype is HIGHLY RECOMMENDED for this sign type to test for structural durability, functionality, and aesthetic quality.
Seam
2
Front View
FS
Scale 1:10
25
42
42
1760
120 225
3
Bottom View
4
Side View
FS
Scale 1:10
FS
Scale 1:5
If weight is an issue, it is optional to use aluminum as construction material; match finish to stainless steel. Adjust thickness of material to allow for welding without creasing and bending.
78 CMA Tower Riyadh, Kingdom of Saudi Arabia
Overhead Directional [OD] Material Identification Material Identification Refer to Material Identification Section
A
A
Ma
B
Structure Side and Bottom Stainless steel marine grade type 316 with satin, medium horizontal brush finish.
G G
C
Legend Type and Divider Line Legend and divider line to be cut out with gray vinyl matching PMS Cool Gray 11C and applied directly to surface of legend plate.
D Suspension Cable Stainless steel cable with a width of 5mm â&#x20AC;&#x201D; 10mm with sufficient strength to safely suspend structure. Consult structural engineer for exact specifications. E
A
F
Au dit ori u
m
F
E C
100
Isometric for Material Identification Scale NTS
SS
MAT
SS
MAT
VY
MAT
SC
MAT
MAT
EG
Directional Arrow Acrylic to be cut and formed to shape of directional arrow (see section of directional arrow for details).
CA
MAT
DA
MAT
CA
MAT
CF
MAT
CA
For digital output, use art file: directional_arrow_art.ai
B
1
MAT
Faceted crystalline pattern to be etched and filled on stainless steel structure (see section of Faceted Crystalline Pattern for details).
D
in Lo bb y
Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish.
G
Crystalline Facet Acrylic to be cut and formed to shape of facet. All films are laminated together and sandwiched between acrylic blocks (see section of Crystalline Graphic Film for details). Light Roof Portion with clear acrylic to allow natural light to illuminate crystalline facet.
79 CMA Tower Riyadh, Kingdom of Saudi Arabia
Overhead Directional [OD] Exploded View Suspension Cable
Fastened securly to support frame
Cover Plate
Compresses the exterior elements to support frame Weld clip rail to exterior skin
Fasteners
Install to upper clip rail
Light Roof
Transparent resin adhered to central bridge. Allows natural and ambient light into the interior of sign structure
Central Bridge
Suspension Locking Plate
Keeps the support frame as one continuous piece
Connection point of suspension cable to support frame. Consult structural engineer for construction based on total weight of structure
Fasteners
Install to upper clip rail from top
Fasteners
Lower Clip Rail
Install to upper clip rail from top
Lower Clip Rail Metal Studs
Metal studs are welded to bottom plate and fastens to lower clip rail
Suspension Cable
Fastened securly to support frame
Horizontal Cross Beam
This is part of the support frame
Cover Plate
Compresses the exterior elements to support frame
Upper Clip Rail
This is part of the support frame
Spacer clip
Bottom Plate
Crystalline etched on to exposed surface of plate
Crystalline Facet Side Rail
Secures acrylic components (crystalline facet) in place. Weld upper and lower clip rail to this component. This section connects the two halves of the structure; allow for adequate structural reinforcement.
Horizontal Cross Beam
Exterior Skin
This portion welded to support frame
Upper Clip Rail
This is part of the support frame
Lower Clip Rail
This is part of the support frame
1 101
Isometric View of Interior Components Scale NTS
Bottom Plate
Etched crystalline pattern
80 CMA Tower Riyadh, Kingdom of Saudi Arabia
Overhead Directional [OD] Exploded View
Auditorium
Legend Plate
45
25 25
Cover Plate Compresses down the components securing the structure together
45
530
20 Clip rail
Ma
in Lo b
3 102
by
Surface of Legend Panel — Front View Scale 1:10
3
Upper clip rail 812
295
295
Viewing Direction
175
649
Legend Plate Apply legend here
Lower clip rail
1 102
Isometric View Scale NTS
2 102
Side View of Legend Panel Scale 1:5
4 102
Surface of Legend Panel — Rear View Scale 1:10
81 CMA Tower Riyadh, Kingdom of Saudi Arabia
Overhead Directional [OD] Section Views
Fasteners install through cover plate and structural frame
Clip
Shaped to form interlocking clip to structural frame; welded to legend plate
Cover Plate 120
Clip welded to legend plate interlocks with support frame
Cover Plate
Flush with fastener 3
26
5
103
Legend Plate
3mm thick
Structure Frame
Clip
Fastener
Structural Frame
Legend Plate
Interior open space
Shaped to form interlocking clip to structural frame; welded to legend plate
Interior open space Interior open space
Slightly angled and conform to overall shape of structure; 3mm thick
Structural Frame
Stud
Fastener
Bottom clip welded to legend plate interlocks with structural frame
Compresses cover plate and legend plates to frame and locks all components in place
4
103
Stud Bottom Panel
Structure Frame
No visible fasteners; secure to structural frame with stud
Legend Plate
3mm thick
Bottom Panel
No visible fasteners; secure to support frame with stud
1 103
Section View Scale 1:3
2 103
Section View Scale 1:3
3 103
Section View â&#x20AC;&#x201D; Detail Scale 1:1
4 103
Section View â&#x20AC;&#x201D; Detail Scale 1:1
82 CMA Tower Riyadh, Kingdom of Saudi Arabia
Overhead Directional [OD] Details of Acrylic Components Spacer Clips
22
Clips are fashioned to secure the acrylic components together and also act as spacers in betweeen the two groups
22
ACRYLIC GROUP 1 Acrylic A
Spacer Clip
Acrylic B
Slightly angled and conform to overall shape of structure; 3mm thick
Clips are fashioned to secure the two acrylic groups together
Cut to fit exactly behind acrylic A; 15mm thick
Exposed to view; 30mm thick
Crystalline Graphic Film
Acrylic B
Cut to fit exactly behind Acrylic A; 15mm thick
ACRYLIC GROUP 2 Acrylic B
Crystalline Graphic Film
Identical as opposite side; see above
Crystalline Graphic Film
Acrylic A 22
Identical as opposite side; see above
3 104
Plan View of Acrylic Groups with Fastening Clips Scale 1:10
112
22
Insert acrylic components here
25
300
20
Insert acrylic components here
25
42
112
Fastener from outward direction securing acrylic components; install through clip
Acrylic A
Exposed to view; 30mm thick
1 104
Acrylic Group Layering Isometric Scale NTS
Fastener Fastener from outward direction securing acrylic components; install through clip
(shaded portion is hidden from view)
2 104
Two Acrylic Groups with Clips Scale NTS
4 104
Front View of Exposed Surface of Acrylic Scale 1:10
5 104
Plan View of Spacer Clip Scale 1:2
83 CMA Tower Riyadh, Kingdom of Saudi Arabia
Area Marker [AM] Measurements, Descriptions, and Construction Details Measurements in millimeters
Fabrication Notes & Requirements Structure should be symmetrical and structurally sound. Use additional structural reinforcement (internal and hidden from view) if necessary from an engineering standpoint. Edges are to be beveled and smoothed-out. Sign should be seamless with no visible fasteners except at plan view. If components are manufactured separately, the overall finish and color of material must be visually identical after assembly. Secure sign structure to ceiling using suspension cable. Production of a full-scale, working prototype is HIGHLY RECOMMENDED for this sign type to test for structural durability, functionality, and aesthetic quality.
120mm
1070mm
Plan View Scale 1:10
2
Front View
105
Scale 1:10
3
Bottom View Scale 1:10
335mm
275mm
45
Crystalline Graphic See section on Crystalline Graphic Film. Allow ambient and natural lighting from environment to enter structure to illuminate the acrylic components.
80mm
85mm
105
Transfer to Level 00
45
25 25
210mm
330mm
5mm
1 105
120mm
450mm
4
Side View
105
Scale 1:10
If weight is an issue, it is optional to use aluminum as construction material; match finish to stainless steel. Adjust thickness of material to allow for welding without creasing and bending.
84 CMA Tower Riyadh, Kingdom of Saudi Arabia
Area Marker [AM] Material Identification
Material Identification Refer to Material Identification Section
A
B
A F F
A
D
C
C
E
Isometric for Material Identification Scale NTS
Legend Type Legend and divider line to be cut out with gray vinyl matching PMS Cool Gray 11C and applied directly to surface of legend plate.
D Suspension Cable Stainless steel cable with a width of 5mm â&#x20AC;&#x201D; 10mm with sufficient strength to safely suspend structure. Consult structural engineer for exact specifications. E
1
Structure Side (Left And Right) Stainless steel marine grade type 316 with satin, medium horizontal brush finish.
MAT
SS
MAT
SS
MAT
VY
MAT
SC
MAT
CA
MAT
CA
MAT
EG
MAT
CF
Faceted crystalline pattern to be etched and filled on stainless steel structure (see section of Faceted Crystalline Pattern for details).
B
106
Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish.
F
Crystalline Facet Acrylic to be cut and formed to shape of facet. All films are laminated together and sandwiched between acrylic blocks (see section of Crystalline Graphic Film for details). Light Roof Portion with clear acrylic to allow natural light to illuminate crystalline facet.
85 CMA Tower Riyadh, Kingdom of Saudi Arabia
Area Marker [AM] Exploded View
Cover plate
Upper clip rail
50mm Legend plate
275mm
210mm
Clip rail
900mm
2 108
Lower clip rail
Surface of Legend Panel â&#x20AC;&#x201D; Rear View Scale 1:10
275
3
Legend plate
1 108
Isometric View Scale NTS
3 108
Side View of Legend Panel Scale 1:5
Viewing Direction
86 CMA Tower Riyadh, Kingdom of Saudi Arabia
Room Announcer [RA] Material Identification Material Identification Refer to Material Identification Section
A
B
Structure Side (Top, Side and Bottom) Stainless steel marine grade type 316 with satin, medium horizontal brush finish.
MAT
SS
MAT
SS
MAT
EG
MAT
EG
MAT
CA
MAT
EG
MAT
CF
Faceted Crystalline pattern to be etched and filled on stainless steel structure (see section of Etched Type and Graphics for details).
E
C
B
Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish.
A
A
Legend Type and Divider Line Legend and divider line to be etched and filled with gray matching PMS Cool Gray 11C on stainless surface (see section of Etched Type and Graphics for details).
D D Etched Graphic Line graphic to be etched and filled with gray matching PMS Cool Gray 11C on stainless surface (see section of Etched Type and Graphics for details).
B
E
C
1 112
Isometric for Material Identification Scale NTS
Crystalline Facet Acrylic to be cut and formed to shape of facet. All films are laminated together and sandwiched between acrylic blocks (see section of Crystalline Graphic Film for details).
87 CMA Tower Riyadh, Kingdom of Saudi Arabia
Room Announcer [RA] Measurements, Descriptions, and Construction Details
50mm
5mm
Unexposed portion of acrylic (shaded)
3
Detail of Plan View
113
Scale 1:2
Isometric View Scale NTS
160mm
25mm
4
100mm
90mm
113
Unexposed portion of acrylic (shaded)
280mm
2 113
Left Side View Scale 1:8
100mm
4 113
Detail of Left Side View Scale 1:3
148mm
1 113
88 CMA Tower Riyadh, Kingdom of Saudi Arabia
Perpendicular Announcer [PA] Material Identification Material Identification Refer to Material Identification Section
A A
B
A
C
B
C
D
1
Front View
115
Scale NTS
Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish. Pictogram Pictogram to be etched and filled with gray matching PMS Cool Gray 11C on stainless surface (see section of Etched Type and Graphics for details). Legend Type and Divider Legend and divider to be etched and filled with gray matching PMS Cool Gray 11C on stainless surface (see section of Etched Type and Graphics for details).
D Crystalline Facet Acrylic to be cast to shape of facet. All films are laminated together and sandwiched between acrylic blocks (see section of Crystalline Graphic Film for details).
MAT
SS
MAT
EG
MAT
EG
MAT
CA
MAT
CF
89 CMA Tower Riyadh, Kingdom of Saudi Arabia
Perpendicular Announcer [PA] Construction Details
Stainless steel
Stainless steel
Graphic film mounted to the front to stainless steel panel
Clear acrylic
Stainless steel Acrylic Group A Corner acrylic Graphic film mounted to the back of clear acrylic
Back plate
Acrylic Group A
Graphic film Corner acrylic Stainless steel (surface for etching) Clear acrylic (cast piece)
Stainless steel (surface for etching)
Acrylic Group B
Acrylic Group B Clear acrylic (cast piece)
1 116
Isometric View Scale NTS
2 116
Isometric Exploded View Scale NTS
Graphic film (folded to conform to shape of acrylic)
Stainless steel (surface for etching)
Clear acrylic (cast piece)
3 116
Isometric of Individual Components Scale NTS
4
Back Plate
116
Scale NTS
90 CMA Tower Riyadh, Kingdom of Saudi Arabia
Small Perpendicular Announcer [PS] Measurements, Descriptions, and Construction Details
125mm
12
115mm
5mm
200mm
3 117
Flat Elevation (Top) Scale 1:3
5mm
85mm
100mm
C2
Height of elevator door
100mm
50mm
200mm
50mm
175mm
100mm
100mm
125mm
125mm
1 117
Small Perpendicular Announcer Scale 1:3
2 117
Right Side View Scale 1:3
4 117
Flat Elevation (Bottom) Scale 1:3
5 117
Typical Elevation Scale 1:25
91 CMA Tower Riyadh, Kingdom of Saudi Arabia
Wall Mounted Directional [WD] Material Identification Material Identification Refer to Material Identification Section
A
B
A B
Info Info Info Info Info
r ma
r ma
r ma r ma r ma
C
C
Info
t io n t io n t io n
Info
D
Info
E
r ma r ma r ma
t io n t io n t io n
Info
r ma
Info t io n
r ma
t io n
E
Front View Scale 1:10
SS
MAT
TA
MAT
EG
MAT
CA
MAT
MA
MAT
CA
MAT
DA
Magnetic Block Magnetic block to be embedded into the clear acrylic and to be concealed from view.
MAT
CF
F E
1
Legend Type and Divider Line Legend and divider line to be etched and filled with gray matching PMS Cool Gray 11C on stainless surface (see section of Etched Type and Graphics for details).
MAT
For digital output, use art file: directional_arrow.ai
F
121
Header and Divider Line R-Cast. Gray matching PMS Cool Gray 11C. Fabricated dimensional letters applied on stainless steel surface.
D Directional Arrow Acrylic to be cut and formed to shape of directional arrow (see section of directional arrow for details).
t io n
t io n
Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish.
F
Crystalline Facet Acrylic to be cut and formed to shape of facet. All films are laminated together and sandwiched between acrylic block and opaque white backing (see section of Crystalline Graphic Film for details).
92 CMA Tower Riyadh, Kingdom of Saudi Arabia
Wall Mounted Directional [WD] Construction Details
1mm 3mm 10mm
Stainless steel Stainless steel Acrylic Dimensional letters
Header with reveal cut
Graphic film
Graphic film
Dimensional letters
Clear acrylic
Viewing Direction
3
Viewing Direction
122
Info Info Info
Info
r ma
t io n Info rm
Legend plate
1 122
Isometric View Scale NTS
a t io
n
Magnet
r ma r ma
t io n t io n
Acrylic Graphic film
Magnet Legend plate
r ma
t io n
Clear acrylic dimensional arrow
Magnet
Legend plate
Graphic film (adhere to the back of acrylic arrow)
2 122
Right Side View Scale 1:10
3 122
Header Side View Scale 1:2
4 122
Header Layering â&#x20AC;&#x201D; Side View Scale 1:2
93 CMA Tower Riyadh, Kingdom of Saudi Arabia
Sign Codes Signage Related Code Compliance
CMA Tower and Capital Market Authority sign system will be complying with the International Building Code (IBC), National Fire Protection Association [NFPA], and American National Standards Institute [ANSI] for all architectural and building issues. Included are signage related code compliance.
IBC — 2009
NFPA 101 — 2009
ANSI 117.1 — 2003
General Building Codes
Fire and Life Safety
Accessibility
Stairs Stair Identification
Stairs Tactile Exit Signs Stair Identification and Landing Information Tactile Level Identification
Communications Visual Character Heights (Directional Signs)
Two-way Communication Systems (instructions regarding the use) Elevators Pictorial Life Safety Signs Self-Evacuation Signs Lobby Status Indicators Ambulance Stretcher Accommodations (Star of Life) Means of Egress Exit Signs (illuminated and tactile) Accessible Routes Areas of Refuge Maximum Occupancy Signs
Exits Tactile Exit Signs Powered Door Signs Egress Egress Identification NO Exit Signs
Room and Space Identification Sign Mounting Heights and Locations Tactile Characters Braille Pictogram Signs International Symbol of Accessibility Elevators Signals (Visible and Audible) Floor Designations (door jambs) Operational Status Evacuation Diagrams (maps) Protruding Objects Parking Spaces
94 CMA Tower Riyadh, Kingdom of Saudi Arabia
All Code Regulated Signs Tactile and Braille
ANSI 117.1 - 2003
ANSI 117.1 — 2003
Tactile Characters
Braille
Depth: Must be raised 1/32 inch (0.8 mm) minimum. Case: All uppercase. The indication of an uppercase letter or letters shall only be used before the first word of sentences, proper nouns and names, individual letters of the alphabet, initials, or acronyms. Style: San serif (no italic, oblique, script or decorative). Height: 5/8 inch (16 mm) height minimum. 2 inch (51 mm) height maximum. Use uppercase “I” to determine character height. Exception: Can be 1/2 inch (13mm) if tactile and visual characters provide the same information. Width: Chracters shall be 55% minimum and 110% maximum width of the uppercase character height. Use uppercase “O” to determine character width. Maximum: 15% of uppercase “I”. Minimum: 10% of uppercase “I”.
Character Spacing: Character spacing shall be measured between the two closest points of adjacent tactile characters within a message, excluding word spaces. Spacing between individual tactile characters shall be 1 /8 inch (3.2 mm) minimum measured at the top surface of the characters, 1 /16 inch (1.6 mm) minimum measured at the base of the characters, and four times the tactile character stroke width maximum. Characters shall be separated from raised borders and decorative elements 3 /8 inch (9.5 mm) minimum.
Type: Braille shall be contracted (Grade 2) Braille. Dimensions: Braille dots shall have a domed or rounded shape and shall comply with Table 703.4.3 (below). Braille Position: Braille shall be below the corresponding text. If text is multilined, Braille shall be placed below entire text. Braille shall be separated 3 /8 inch (9.5 mm) minimum from any other tactile characters and 3 /8 inch (9.5 mm) minimum from raised borders and decorative elements. Braille provided on elevator car controls shall be separated 3 /16 inch (4.8 mm) minimum either directly below or adjacent to the corresponding raised characters or symbols.
Line Spacing: Spacing between the baselines of separate lines of tactile characters within a message shall be 135% minimum and 170% maximum of the tactile character height. Finish and Contrast: Characters and their background shall have a nonglare finish. Characters shall contrast with their background, with either light characters on a dark background, or dark characters on a light background.
Distance between dots in the same cell
Distance between dots in adjacent cell Single Braille cell
Distance between dots in the same cell
Distance between corresponding dots from one cell directly below
Blank cell space between words Raised dot
9.5mm
Dot diameter No raised dot 9.5mm
Table 703.4.3
95 CMA Tower Riyadh, Kingdom of Saudi Arabia
Room Number [RN] Measurements, Descriptions, and Construction Details
Crystalline Graphic Film The iridescent, translucent, and vibrant qualities of the crystalline graphics are achieved through the layering of serveral different materialsâ&#x20AC;&#x201D;each with its unique visual qualityâ&#x20AC;&#x201D;and laminated as a single surface placed behind the clear acrylic block.
1mm metal backing painted white on all sides
SOLYX (sxlt-1302) Clear Icicles SOLYX Bahama Print on HDTE clear film
Acrylic block
Stainless steel with satin finish Cut out on stainless steel face Polished clear acrylic Braille
1 126
Layering Composition Scale NTS
96 CMA Tower Riyadh, Kingdom of Saudi Arabia
Room Number and Room Identification [RN][RI] Material Identification Material Identification Refer to Material Identification Section
A A D B
B
C D G
1
3
CMA Room Number Sign - Isometric for Material Identification
128
C
128
Scale NTS
CMA Tower Room Number Sign - Isometric for Material Identification
Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish. Room Number Clear acrylic. Fabricated dimensional letters push-through stainless steel surface.
MAT
SS
MAT
CA
MAT
EG
MAT
MA
MAT
EG
MAT
CA
Braille Braille must be Grade 2 with domed or rounded shape (see Tactile and Braille section).
Scale NTS D Etched Graphic Line graphic to be etched and filled with gray matching PMS Cool Gray 11C on stainless surface (see section of Etched Type and Graphics for details).
A E
D B
Magnetic Block Magnetic block to be embedded into the clear acrylic and to be concealed from view.
C F
D E
Legend Type and Divider Line Legend and line to be etched and filled with gray matching PMS Cool Gray 11C on stainless surface (see section of Etched Type and Graphics for details).
F
2 128
CMA Room Identification Sign - Isometric for Material Identification Scale NTS
4 128
CMA Tower Room Identification Sign - Isometric for Material Identification Scale NTS
G Crystalline Facet Acrylic to be cut and formed to shape of facet. All films are laminated together and sandwiched between acrylic block and opaque white backing (see section of Crystalline Graphic Film for details).
MAT
CF
97 CMA Tower Riyadh, Kingdom of Saudi Arabia
Room Identification [RI] Measurements, Descriptions, and Construction Details
Detailed Material and Dimension Callouts
Fabricated room numbers adhere to surface. Use the same translucent material as the core of sign
Additional information on material usage and dimensions for final fabrication process.
200mm
1mm
90mm
20mm High quality graphic output of pattern and color on foil (metallic sheen) paper
5mm
16mm
Optically clear, transparent acrylic with diamond polished edges
70mm
75mm
25mm
2mm
4mm
2mm
Viewing Direction Routed to fit magnet stripes
Large Conference Room Stainless steel veneer with satin finish
1 129
Room Identification Sign Front View Scale 3:4
Legend to be etched and filled on stainless surface; 9mm at Alif and X height
Magnet B: Adhere to legend plate Legend plate
9mm
40mm
9mm
Magnet A: Adhere to sign
Etched line graphic
2
Side View
129
Scale 3:4
98 CMA Tower Riyadh, Kingdom of Saudi Arabia
Room Identification [RI] Measurements, Descriptions, and Construction Details
Detailed Material and Dimension Callouts
Fabricated room numbers adhere to surface. Use the same translucent material as the core of sign
Additional information on material usage and dimensions for final fabrication process.
200mm 1mm
140mm
20mm 16mm
8mm
56mm
High quality graphic output of pattern and color on foil (metallic sheen) paper
42mm
2mm
75mm
Optically clear, transparent acrylic with diamond polished edges
4mm
2mm
Viewing Direction Routed to fit magnet stripes Magnet A: Adhere to sign
40mm
Magnet B: Adhere to legend plate
Large Conference Room Stainless steel veneer with satin finish
1 130
Room Identification Sign Front View Scale 3:4
Legend plate
Legend to be etched and filled on stainless surface
Etched line graphic
2
Side View
130
Scale 3:4
99 CMA Tower Riyadh, Kingdom of Saudi Arabia
Support Room Identification [SI] Measurements, Descriptions, and Construction Details
Fabricated room numbers 2mm thick acrylic, painted black, and adhered to metal surface
165mm 13mm
1 132
Scale 3:4
Braille
Graphic output or back painted Tactile Braille Viewing Direction
9mm
10mm 19mm
Room Identification Sign Front View (Typical)
Legend to be etched and filled on stainless surface
1mm stainless steel plate
6mm clear acrylic
8mm
Stainless steel veneer with satin finish
9mm 7mm
9mm
2mm 20mm
40mm
Large Conference Room
2mm
4mm
64mm
18mm
All legends and Braille to be flushed left
2
Side View
132
Scale 3:4
3mm opening
100 CMA Tower Riyadh, Kingdom of Saudi Arabia
Support Room Number and Support Room Identification [SN][SI] Material Identification Material Identification Refer to Material Identification Section
A
B
C
E
B C D
F E
F
1
CMA Support Room Number Sign - Isometric for Material Identification Scale NTS
MAT
SS
MAT
TA
MAT
MA
Legend Type and Divider Line Legend and divider line to be cut out with gray vinyl matching PMS Cool Gray 11C and applied directly to surface of Legend Plate.
MAT
VY
Crystalline Facet All films are laminated together and sandwiched between acrylic block and opaque white backing (see section of Crystalline Graphic Film for details).
MAT
CA
Room Number R-Cast. Gray matching PMS Cool Gray 11C. Fabricated dimensional letters applied on stainless steel surface. Braille Braille must be Grade 2 with domed or rounded shape (see Tactile and Braille section).
D Magnetic Block Magnetic block to be embedded into the clear acrylic and to be concealed from view.
A
133
Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish.
2 133
CMA Tower Support Room Identification Sign - Isometric Scale NTS
MAT
CF
101 CMA Tower Riyadh, Kingdom of Saudi Arabia
Installation Detail Room Number and Room Identification Sign
Note: The preferred method of installation is OPTION A. Choice of installation method based on sign location’s circumstances and should be attempted in the order of A,B,C and D until sign is successfully installed. Use below installation method for various wall mounted signs.
PREFERRED METHOD
1 135
Install sign on strike side of door. Allow 75mm from edge of door frame and 1500mm from top of sign to finished floor.
Preferred Installation — Option A Scale 1:30
Install sign on strike side of door. Allow 75mm from obstruction to right edge of sign but no more than 460mm from edge of door frame. 1500mm from top of sign to finished floor.
2 135
Installation — Option B Scale 1:30
75mm
75mm
75mm
75mm
75mm
75mm
75mm
Install sign on opposite to strike side of door. Allow 75mm from door frame or obstruction to left edge of sign but no more than 460mm from edge of door frame. 1500mm from top edge of sign to finished floor.
3 135
Installation — Option C Scale 1:30
Install sign directly on door if both sides are obstructed. Center sign on door and 1500mm from top edge of sign to finished floor.
4 135
Installation — Option D Scale 1:30
102 CMA Tower Riyadh, Kingdom of Saudi Arabia
Pictogram Sign [PT] Measurements, Descriptions, and Construction Details
160mm
ANSI 117.1 - 2003 Tactile Characters
20mm
Refer to specifications on Tactile and Braille page.
Braille Refer to specifications on Tactile and Braille page.
160mm
1 136
15mm
3
CMA Pictogram Sign
136
Scale 1:3
CMA Tower Pictogram Sign Scale 1:3
15mm
Pictogram Field Pictograms shall have a field 6 inches (150 mm) minimum in height. Characters or Braille shall not be located in the pictogram field.
Finish and Contrast Pictograms and their fields shall have a nonglare finish. Pictograms shall contrast with their fields, with either a
150 mm (6â&#x20AC;? minimum)
light pictogram on a dark field or a dark pictogram on a light field.
150 mm (6â&#x20AC;? minimum)
Text Descriptors 270mm
Where text descriptors for pictograms are required, they shall be located directly below the pictogram field. 10 mm
Finish and Contrast
16mm
Symbols of accessibility and their backgrounds shall have
12mm
a nonglare finish. Symbols of accessibility shall contrast
16mm
with their backgrounds, with either a light symbol on a
10mm
dark background or a dark symbol on a light background.
10 mm
MEN
16mm 12mm 16mm 10 mm
MEN
15mm
2 136
CMA Pictogram Sign Scale 1:3
4 136
CMA Tower Pictogram Sign Scale 1:3
15mm
103 CMA Tower Riyadh, Kingdom of Saudi Arabia
Pictogram Sign [PT] Material Identification Material Identification Refer to Material Identification Section
A
B
A F C
B
Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish. Pictogram R-Cast. Gray matching PMS Cool Gray 11C. Fabricated dimensional letters applied on stainless steel surface. Legend Type R-Cast. Gray matching PMS Cool Gray 11C. Fabricated dimensional letters applied on stainless steel surface.
D Divider Line Divider line to be etched and filled with gray matching PMS Cool Gray 11C on stainless surface (see section of Etched Type and Graphics for details).
E
Braille Braille must be Grade 2 with domed or rounded shape (see Tactile and Braille section).
F
Crystalline Facet Acrylic to be cut and formed to shape of facet. All films are laminated together and sandwiched between acrylic block and opaque white backing (see section of Crystalline Graphic Film for details).
C
D
E
F
1 137
CMA Pictogram Sign - Isometric for Material Identification Scale NTS
2 137
CMA Tower Pictogram Sign - Isometric for Material Identification Scale NTS
MAT
SS
MAT
TA
MAT
TA
MAT
EG
MAT
CA
MAT
CF
104 CMA Tower Riyadh, Kingdom of Saudi Arabia
Elevator/Lift Landing and Service Elevator [EE][SE] Measurements, Descriptions, and Construction Details
IBC â&#x20AC;&#x201D; 2009
letter height of in. (16 mm) posted in every elevator lobby: (1)* Signs that indicate that the elevator can be used for
1
3
CMA Elevator/Lift Landing Sign Plan View
138
138
Scale 1:5
6mm
1mm
7.2.13.1) shall have the following signs with a minimum
20mm
Elevators that are a part of a means of egress (see
15mm
290mm
7.10.8.4 Elevator Signs
5
CMA Elevator/Lift Landing Sign Bottom View
Service Elevator/Lift Landing Sign Plan View
138
Scale 1:5
Scale 1:5
egress, including any restrictions on use;
112mm
(2)* Signs that indicate the operational status of elevators.
185mm
Tower Security
123- 4567
Fire Depar tment
2
2
CMA Elevator/Lift Landing Sign Front View Scale 1:8
Legend Key Elevator
Legend Key Elevator Stair way
Stair way E xit Route E xit Route
4 138
123- 4567
Tower Security
123- 4567
Fire Depar tment
You Are Here
CMA Tower Elevator/Lift Landing Sign Front View Scale 1:8
526mm
Evacuation Plan
You Are Here
FS
138
Evacuation Plan
10mm
123- 4567
30
LE VEL
LE VEL
You Are Here
20mm
112mm
30
Legend Key Elevator Stair way
E xit Route
6 138
123- 4567
Tower Security
123- 4567
Fire Depar tment
10mm
185mm
Evacuation Plan
IN FIRE EMERGENCY, DO NOT USE ELEVATOR. USE EXIT STAIRS.
2mm
30
LE VEL
IN FIRE EMERGENCY, DO NOT USE ELEVATOR. USE EXIT STAIRS.
185mm
IN FIRE EMERGENCY, DO NOT USE ELEVATOR. USE EXIT STAIRS.
585mm
acceptable to the authority having jurisdiction.
85mm
112mm
shall be posted and oriented in a location and manner
112mm
reflecting the actual floor arrangement and exit locations
585mm
Chapters 11 through 43, floor evacuation diagrams
85mm
85mm
Where a posted floor evacuation map is required in
1
FS
112mm
7.10.8.5* Evacuation Map
Service Elevator/Lift Landing Sign Front View Scale 1:8
105 CMA Tower Riyadh, Kingdom of Saudi Arabia
Elevator/Lift Landing and Service Elevator [EE][SE] Measurements, Descriptions, and Construction Details
Digital print mounted to the back of clear acrylic
Acrylic and map insert slides in
Routed to fit in slider
Routed to receive acrylic panel Routed insert slot in acrylic
Refer to section in Mapping Graphics for additional information on maps
1 141
Isometric View Scale NTS
2 141
Isometric View Scale NTS
3 141
Isometric View Scale NTS
106 CMA Tower Riyadh, Kingdom of Saudi Arabia
Evacuation Map [EM] Measurements, Descriptions, and Construction Details
300mm 260mm
Four-color silkscreen map graphic
1
Plan View
142
Scale 1:4
20mm 150mm radius hexagon 130mm radius hexagon
Stainless steel Magnet adheres to plate Clear acrylic
Graphic output
130mm
2 142
150mm Front View Scale 1:4
3 142
Right Side View Scale 1:4
4
Isometric
142
Scale NTS
107 CMA Tower Riyadh, Kingdom of Saudi Arabia
Stair Door Identification [ST] Measurements, Descriptions, and Construction Details
160mm
160mm
ANSI 117.1 — 2003 Pictogram Field
Same as for pictogram signs if pictograms are used.
Tactile Characters Refer to specifications on Tactile and Braille page.
20mm
1 144
20mm
IBC — 2009 1011.3 Tactile Exit Signs
A tactile sign stating EXIT and complying with ICC A117.1 shall be provided adjacent to each door to an area of refuge, an exterior area for assisted rescue, an exit stairway, an exit ramp, an exit passageway and the exit discharge.
NFPA 101 — 2009
144
Scale 1:4
CMA Tower Stair Door ID Sign Plan View Scale 1:4
15mm
Braille Refer to specifications on Tactile and Braille page.
3
CMA Stair Door ID Sign Plan View
15mm 16mm
12mm 16mm 10mm
STAIR A
10mm
STAIR A
16mm 10mm
STAIR A
10mm EXIT
150mm 370mm
7.10.1.3 Exit Door Tactile Signage
Tactile signage shall be provided to meet the following criteria, unless otherwise provided in 7.10.1.4: (1) Tactile signage shall be located at each exit door requiring an exit sign. (2) Tactile signage shall read as follows: EXIT. (3) Tactile signage shall comply with ICC/ANSI A117.1, American National Standard for Accessible and Usable Buildings and Facilities.
16mm 12mm
150mm
10mm 16mm 12mm 16mm 10mm
455mm
EXIT
10mm
EXIT
7.2.2.5.4 Stairway Identification
16mm 12mm 16mm
See ANSI 117.1 installation requirements
10mm 15mm
Stair identification needs to be letters not numbers. These signs to be located on the occupancy or entrance side of the stairwell.
15mm
2 144
CMA Stair Door ID Sign Front View Scale 1:4
4 144
CMA Tower Stair Door ID Sign Front View Scale 1:4
5 144
Typical Elevation Scale 1:25
108 CMA Tower Riyadh, Kingdom of Saudi Arabia
Stairway Identification [SW] Measurements, Descriptions, and Construction Details
7.2.2.5.4* Stairway Identification
7.2.2.5.4.1 New enclosed stairs serving three or more stories and existing enclosed stairs serving five or more stories shall comply with 7.2.2.5.4.1(A) through (M). (A) The stairs shall be provided with special signage within the enclosure at each floor landing. (B) The signage shall indicate the floor level. (C) The signage shall indicate the terminus of the top and bottom of the stair enclosure. (D) The signage shall indicate the identification of the stair enclosure. (E) The signage shall indicate the floor level of, and the direction to, exit discharge. (F) The signage shall be located inside the enclosure approximately 60 in. (1525 mm) above the floor landing in a position that is visible when the door is in the open or closed position. (G) The signage shall comply with 7.10.8.1 and 7.10.8.2 of this Code. (H) The floor level designation shall also be tactile in accordance with ICC/ANSI A117.1, American National Standard for Accessible and Usable Buildings and Facilities. (I) The signage shall be painted or stenciled on the wall or on a separate sign securely attached to the wall. (J) The stairway identification letter shall be located at the top of the sign in minimum 1 in. (25 mm) high lettering and shall be in accordance with 7.10.8.2.
370
(K)* Signage that reads NO ROOF ACCESS and is located under the stairway identification letter shall designate stairways that do not provide roof access. Lettering shall be a minimum of 1 in. (25 mm) high and shall be in accordance with 7.10.8.2. (L) The floor level number shall be located in the middle of the sign in minimum 5 in. (125 mm) high numbers and shall be in accordance with 7.10.8.2. Mezzanine levels shall have the letter “M” or other appropriate identification letter preceding the floor number, while basement levels shall have the letter “B” or other appropriate identification letter preceding the floor level number. (M) Identification of the lower and upper terminus of the stairway shall be located at the bottom of the sign in minimum 1 in. (25 mm) high letters or numbers and shall be in accordance with 7.10.8.2. 7.2.2.5.4.2 Wherever an enclosed stair requires travel in an upward direction to reach the level of exit discharge, special signs with directional indicators showing the direction to the level of exit discharge shall be provided at each floor level landing from which upward direction of travel is required, unless otherwise provided in 7.2.2.5.4.2
25
FLOOR
30
1mm stainless steel plate
25 6mm clear acrylic
30 Graphic output or back painted
125
30 25
3
3mm opening
25
B1 TO 65th FLOOR
20 25 25 25
NO ROOF ACCESS
(A) and 7.2.2.5.4.2(B), and the following also shall apply: (1) Such signage shall comply with 7.10.8.1 and 7.10.8.2. (2) Such signage shall be visible when the door leaf is in the open or closed position. (A) The requirement of 7.2.2.5.4.2 shall not apply where signs required by 7.2.2.5.4.1 are provided. (B) The requirement of 7.2.2.5.4.2 shall not apply to stairs extending not more than one story below the level of exit discharge where the exit discharge is clearly obvious.
30
STAIR A
62
630
NFPA 101 — 2009
DOWN TO 1ST FLOOR FOR EXIT DISCHARGE
20 25 15 15 15 18 15 15
8
8
30
1 146
CMA Tower Stairwell Identification at Landings Scale 1:5
2
Side View
146
Scale 1:5
109 CMA Tower Riyadh, Kingdom of Saudi Arabia
Stairway Level Sign [SL] Measurements, Descriptions, and Construction Details
ANSI 117.1 — 2003 Tactile Characters Refer to specifications on Tactile and Braille page.
Braille Refer to specifications on Tactile and Braille page.
IBC — 2009
Need specific code references.
NFPA 101 — 2009
1 mm
90mm
7.2.2.5.4 Stairway Identification
110mm
15mm
(H) The floor level designation shall also be tactile in accordance with ICC/ANSI A117.1, American National Standard for Accessible and Usable Buildings and Facilities.
53 90mm
50mm
10mm 10mm 455mm
LIFT CS1-CS3
See ANSI 117.1 installation requirements
STAIR C
1 Proposed Typical Sign Location
148
Typical Sign Layout Scale 1:2
2 148
Side View
3
Scale 1:2
148
Egress Level Layout Scale 1:2
4 148
Typical Elevation Scale 1:25
110 CMA Tower Riyadh, Kingdom of Saudi Arabia
No Exit Sign [NE] Measurements, Descriptions, and Construction Details
95 mm
NFPA - 2009 7.10.8.3* No Exit 7.10.8.3.1
Center pictogram within field
115 mm
Any door, passage, or stairway that is neither an exit nor a way of exit access and that is located or arranged so that it is likely to be mistaken for an exit shall be identified by a sign that reads as follows:
NO
140 mm
EXIT
7.10.8.3.2 The NO EXIT sign shall have the word NO in letters 2 in. 115 mm
(~50 mm) high, with a stroke width of 3/8 in. (9.5 mm), and the word EXIT in letters 1 in. (25 mm) high, with the word EXIT below the word NO, unless such sign is an
Size of Arabic message adjustable
12mm
NO EXIT
15mm
50mm
12mm
131 mm
115 mm
approved existing sign.
25mm 15mm
NO EXIT
10mm 15mm
12mm
12mm 12mm
1 150
No Exit Sign Sample Layout Scale 1:3
2 150
No Exit Sign Sample Layout Scale 1:3
3
Side View
150
Scale 1:3
111 CMA Tower Riyadh, Kingdom of Saudi Arabia
Exit Door Sign [ED] Measurements, Descriptions, and Construction Details 150 mm field required for pictograms if they are utilized (typical exit symbol) Pictograms not required
115mm
IBC — 2009
6mm
1011.3 Tactile Exit Signs
A tactile sign stating EXIT and complying with ICC A117.1 shall be provided adjacent to each door to an area of refuge, an exterior area for assisted rescue, an exit stairway, an exit ramp, an exit passageway and the exit discharge.
1mm stainless steel plate
30mm
Clear acrylic
NFPA 101 — 2009 7.10.1.3 Exit Door Tactile Signage
Tactile signage shall be provided to meet the following criteria, unless otherwise provided in 7.10.1.4: (1) Tactile signage shall be located at each exit door requiring an exit sign. (2) Tactile signage shall read as follows: EXIT. (3) Tactile signage shall comply with ICC/ANSI A117.1, American National Standard for Accessible and Usable Buildings and Facilities.
150mm
See ANSI 117.1 installation requirements 238mm 30mm EXIT
7.2.2.5.5.8 Emergency Exit Symbol
16mm
12mm 16mm
10mm
15mm
Pictogram Field: Same as for pictogram signs if
15mm
pictograms are used.
Braille: Refer to specifications on Tactile and Braille page.
EXIT 455mm
ANSI 117.1 — 2003 Tactile Characters: Refer to specifications on Tactile
Open to acrylic
3mm 10mm
An emergency exit symbol with a luminescent background shall be applied on all doors serving the exit enclosure that swing out from the enclosure in the direction of egress travel. The emergency exit symbol shall also meet the following requirements: (1) The emergency exit symbol shall meet the requirements of NFPA 170, Standard for Fire Safety and Emergency Symbols. (2) The emergency exit symbol applied on the door shall be no higher than 18 in. (455 mm) above the finished floor.
and Braille page.
Graphic output or back painted
1 152
Front View Scale 1:2
2
Side View
152
3
Scale 1:2
152
Typical Elevation Scale 1:25
112 CMA Tower Riyadh, Kingdom of Saudi Arabia
Area of Refuge [AR] Measurements, Descriptions, and Construction Details
Metal
1. Each door providing access to an area of refuge from an adjacent floor area shall be identified by a sign stating: AREA OF REFUGE. 2. Each door providing access to an exterior area for assisted rescue shall be identified by a sign stating: EXTERIOR AREA FOR ASSISTED RESCUE. Signage shall comply with the ICC A117.1 requirements for visual characters and include the International Symbol of Accessibility. Where exit sign illumination is required by Section 1011.2, the signs shall be illuminated. Additionally, tactile signage complying with ICC A117.1 shall be located at each door to an area of refuge and exterior area for assisted rescue in accordance with Section 1011.3.
1007.10 Directional Signage
Directional signage indicating the location of the other means of egress and which are accessible means of egress shall be provided at the following:
6mm
15 mm
15 mm
1mm stainless steel plate
16 mm
1. Persons able to use the exit stairway do so as soon as possible, unless they are assisting others.
12 mm 16 mm
2. Information on planned availability of assistance in the use of stairs or supervised operation of elevators and how to summon such assistance.
10 mm
AREA OF REFUGE
Clear acrylic
10 mm
3mm opening
3. Directions for use of the two-way communications system where provided.
1011.2 Illumination
Exit signs shall be internally or externally illuminated. Exception: Tactile signs required by Section 1011.3 need not be provided with illumination.
326mm
Signage indicating special accessibility provisions shall be provided as shown:
210mm
In areas of refuge and exterior areas for assisted rescue, instructions on the use of the area under emergency conditions shall be posted. The instructions shall include all of the following:
85mm
1007.9 Signage
1007.11 Instructions
150 mm (6â&#x20AC;? minimum)
1011.3 Tactile Exit Signs
Graphic output or back painted
A tactile sign stating EXIT and complying with ICC A117.1 shall be provided adjacent to each door to an area of refuge, an exterior area for assisted rescue, an exit stairway, an exit ramp, an exit passageway and the exit discharge.
3mm opening
10 mm 16 mm
1. At exits serving a required accessible space but not providing an approved accessible means of egress.
12 mm
2. At elevator landings.
10 mm
3. Within areas of refuge.
15 mm
16 mm
International Symbol of Accessibility
1 154
Front View Scale 3:8
EXIT
85mm
IBC - 2009
150mm field required for pictograms (potential A of R symbol)
2
Side View
154
Scale 3:8
113 CMA Tower Riyadh, Kingdom of Saudi Arabia
Two-Way Communication Sign [TW] Measurements, Descriptions, and Construction Details
IBC â&#x20AC;&#x201D; 2009
Metal
240mm
English message TBD
1007.6.3 Two-Way Communication
Areas of refuge shall be provided with a two-way communication system complying with Sections 1007.8.1 and 1007.8.2.
1007.8 Two-Way Communication
A two-way communication system shall be provided at the elevator landing on each accessible floor that is one or more stories above or below the story of exit discharge complying with Sections 1007.8.1 and 1007.8.2.
150mm
In the event of emergency, this phone will provide direct contact to security and emergency personnel.
Exceptions:
1. Two-way communication systems are not required at the elevator landing where the two-way communication system is provided within areas of refuge in accordance with Section 1007.6.3. 2. Two-way communication systems are not required on floors provided with exit ramps conforming to the provisions of Section 1010.
In the event of emergency, this phone will provide direct contact to security and emergency personnel.
EMERGENCY PHONE
3mm
1007.8.1 System Requirements
Two-way communication systems shall provide communication between each required location and the fire command center or a central control point location approved by the fire department. Where the central control point is not constantly attended, a two-way communication system shall have a timed automatic telephone dial-out capability to a monitoring location or 911. The two-way communication system shall include both audible and visible signals.
85mm
EMERGENCY PHONE
1007.8.2 Directions
Directions for the use of the two-way communication system, instructions for summoning assistance via the two-way communication system and written identification of the location shall be posted adjacent to the two-way communication system.
1 156
Front View Scale 1:2
2 156
Two-Way Communication Identification Sign Scale NTS
114 CMA Tower Riyadh, Kingdom of Saudi Arabia
Occupancy Load [OL] Measurements, Descriptions, and Construction Details
IBC â&#x20AC;&#x201D; 2009 1004.3 Posting of Occupant Load
Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent.
Message etched and filled
1 mm
1 159
Front View Scale 1:1
10mm 10mm 30mm
90mm
50
10mm
Maximum Occupancy
10mm
10mm
10mm
160mm
2
Side View
159
Scale 1:1
115 CMA Tower Riyadh, Kingdom of Saudi Arabia
Powered Door Leaf Sign [PD] Measurements, Descriptions, and Construction Details
NFPA 101 â&#x20AC;&#x201D; 2009 7.2.1.9* Powered Door Leaf Operation
7.2.1.9.1* General. Where means of egress door leaves are operated by power upon the approach of a person or are provided with power-assisted manual operation, the design shall be such that, in the event of power failure, the leaves open manually to allow egress travel or close when necessary to safeguard the means of egress.
Tactile exit sign required
7.2.1.9.1.1 The forces required to manually open the door leaves specified in 7.2.1.9.1 shall not exceed those required in 7.2.1.4.5, except that the force required to set the leaf in motion shall not exceed 50 lbf (222 N).
20mm 60mm
EXIT
4mm
7.2.1.9.1.2 The door assembly shall be designed and installed so that, when a force is applied to the door leaf on the side from which egress is made, it shall be capable of swinging from any position to provide full use of the required width of the opening in which it is installed. (See 7.2.1.4.)
60mm from edge of door
IN EMERGENCY, PUSH TO OPEN
25mm
20mm
7.2.1.9.1.3 A readily visible, durable sign in letters not less than 1 in. (25 mm) high on a contrasting background that reads as follows shall be located on the egress side of each door opening: IN EMERGENCY, PUSH TO OPEN 7.2.1.9.1.4 Sliding, power-operated door assemblies in an exit access serving an occupant load of fewer than 50 that manually open in the direction of door leaf travel, with forces not exceeding those required in 7.2.1.4.5, shall not be required to have the swing-out feature required by 7.2.1.9.1.2. The required sign shall be in letters not less than 1 in. (25 mm) high on a contrasting background and shall read as follows: IN EMERGENCY, SLIDE TO OPEN
25mm
Vinyl adheres to door
1 162
Powered Door Leaf Signs Scale 1:5
2 162
Typical Elevation Scale 1:25
116 CMA Tower Riyadh, Kingdom of Saudi Arabia
Delayed Egress Door and Powered Door Leaf Sign [DE][PD] Material Identification Material Identification Refer to Material Identification Section
A
A
1 163
CMA Delayed Egress Locking Systems Scale NTS
A
2 163
CMA Powered Door Leaf Sign Scale NTS
Legend Type and Divider Line Legend and divider line to be cut out with gray vinyl matching PMS Cool Gray 11C and applied directly to surface of legend plate.
MAT
VY
117 CMA Tower Riyadh, Kingdom of Saudi Arabia
Fabricated Cut Out Logo [CO] Material Identification Material Identification Refer to Material Identification Section
A
Size to be proportionally scaled to wall size. Consult architect/designer for size and location
A
75mm
Install at high sight line above obstructions proportional to size of wall
75mm
Reception desk
B
NOTE: Final logo TBD; drawings for illustration purposes only
1 164
CMA Fabricated Logo Scale 1:30
2
Isometric
164
Scale NTS
B
Logotype 75mm chrome polished dimensional fabricated letters pin mounted flush to the wall. Stainless steel faces and sides with crisp edges, square corners and clean lines. Logo Stainless steel sides. Clear acrylic face and backer sandwich digitally output film graphics. Internally illuminated.
MAT
SS
MAT
SS
MAT
CA
118 CMA Tower Riyadh, Kingdom of Saudi Arabia
Desk Display [DE] Material Identification
Material Identification Refer to Material Identification Section
A
B
A
Plate Clear acrylic serves as protective glass to paper insert. Must be optically clear without detracting from image quality. Bevel and finish all edges. Legend Type R-Cast. Gray matching PMS Cool Gray 11C. Fabricated dimensional letters applied on stainless steel surface.
MAT
CA
MAT
TA
MAT
CA
MAT
CA
B C
C D
Structure Clear acrylic serves as protective glass to paper insert. Must be optically clear without detracting from image quality. Bevel and finish all edges.
D Crystalline Facet Acrylic to be cut and formed to shape of facet. All films are laminated together and sandwiched between acrylic block and opaque white backing (see section of Crystalline Graphic Film for details).
1 166
Isometric for Material Identification Scale NTS
MAT
CF
119 CMA Tower Riyadh, Kingdom of Saudi Arabia
Window Vinyl [WV] Material Identification Material Identification Refer to Material Identification Section Final copy to be determined by PMT A
B
A
Sun. — Thurs. 0:00 - 00:00 Fri. — Sat. 0:00 - 00:00
C
123-456-7890
Business Hours:
Sun. — Thurs. 0:00 - 00:00 Fri. — Sat. 0:00 - 00:00 Tower Security 123-456-7890
1 167
Window Vinyl Scale 1:25
400mm
C
Accessible No Photos No Smoking
B
Graphic Band High quality digital print out on clear film. Vinyl to be applied in the interior glass surface. Final art available in 4 patterns of 800mm by 400mm. Tile pattern randomly for continuous look. Area for Pictograms and/or Prohibitive Messages Vinyl cut out letters and pictograms. Gray matching PMS Cool gray 11C (see section of Icons and Pictographs for more options). Area for Business and Contact Information Vinyl cut out letters. Silver metallic vinyl, UV rated (see section of Typography for type usage information).
MAT
GF
MAT
VY
MAT
VY
MAT
DO
Exterior Signage Details of North, South, and Plaza Announcer
121 CMA Tower Riyadh, Kingdom of Saudi Arabia
Major Tower Announcers Locations on Plan
Sized for visibility at the range of 50 ft. (15.25m) or more from the viewer. All announcers must be properly illuminated using external and internal light source. Dimensional announcers are preferred for multi-directional viewing.
North
North and South Entrance Design of grand announcer to complement the triangular form of the architecture opening to the entrance. To be positioned within the limits of work and fully visible to viewers in vehicles entering the drop-off. Plaza Announcer Adding CMA Tower presence to passing traffic or surrounding buildings in the southeastern direction of the tower. Announcer at this location can also serve as an artistic feature to the spacious plaza.
South
Plaza
Line of Sight
122 CMA Tower Riyadh, Kingdom of Saudi Arabia
North Exterior Announcer Measurements, Descriptions, and Construction Details Measurements in millimeters
Design Intent Highest quality materials and utmost level of workmanship required in the fabrication of the sign’s structure. Serves as premier entry marker, sign’s primary purpose is to “present” the tower’s logo in a regal, prestigious, and attractive way. The intent is to exemplify the crystalline quality of a gem stone unearthed from the ground.
1
180
Fabrication Notes & Requirements 1477
Parts and components must be made to fit with minimum amount and size (>1mm of opening seams) of visible seams. The choice of materials must be weather resistant and durable under local weather conditions. UV coating (to resist color fading) and non-glare coating on glass, acrylic, and other reflective surfaces is highly recommended. Use non-corrosive metal alloys but stainless steel is preferrable as the main building material.
2480
Area for Logo Logo TBD / choose option of logo suitable for horizontal layout
1003
Internal Lighting Consult lighting designer / electrician for specifications. External Lighting Consult lighting designer / electrician for specifications. Color-treated Glass Use a fade-resistant color process. Structural Consult structural engineer for review prior to fabrication. 4000
1
Front View
171
Scale 1:20
123 CMA Tower Riyadh, Kingdom of Saudi Arabia
North Exterior Announcer Measurements, Descriptions, and Construction Details
2363
1
181
1477
156
2480
Viewing Direction 18
1003
20
578
1 172
Right Side View Scale 1:20
4000
2
Rear View
172
Scale 1:20
124 CMA Tower Riyadh, Kingdom of Saudi Arabia
North Exterior Announcer Measurements, Descriptions, and Construction Details
4000
578
206
Back glass: color-treated glass
Clear acrylic logo with metal veneer as face
Front glass: clear tempered glass
Viewing Direction
1
Plan View
173
Scale 1:15
Back glass: color-treated glass
Viewing Direction
2 173
Plan View â&#x20AC;&#x201D;Â Sans Logo Scale 1:15
Spot lighting aim upward at logo; lights to inset within structure
125 CMA Tower Riyadh, Kingdom of Saudi Arabia
North Exterior Announcer Facets Identification of Base Structure â&#x20AC;&#x201D; Front
2365
438
1255
487
185
Upper Platform Surface Surface
3
5
Surface
9
Surface
2
10
Surface
1003
Surface
Surface
6
8
Surface
1
Surface
Surface
4
Footprint
133
748
211
345
1024
4000
1 174
Front Geometric Surfaces Scale 1:20
Surface
7
11
660
879
126 CMA Tower Riyadh, Kingdom of Saudi Arabia
North Exterior Announcer Facets Identification of Base Structure â&#x20AC;&#x201D; Front
2
Surface
Surface
FS
9
5
Surface
18
Surface
19
Surface
11
3
FS
Surface Surface
1
1 175
Geometric Surfaces Scale NTS
Surface
2
Surface
3
10
Surface Surface
4
6
Surface Surface
7
8
127 CMA Tower Riyadh, Kingdom of Saudi Arabia
North Exterior Announcer Facets Identification of Base Structure â&#x20AC;&#x201D; Rear
2365
946
815
604
Surface
Surface
12
Surface
13
18
Surface
Surface
1003
17
15
Surface
18
Surface
Surface
16
14
Surface
19
1660
1625
4000
1 176
Rear Geometric Surfaces Scale 1:20
715
128 CMA Tower Riyadh, Kingdom of Saudi Arabia
North Exterior Announcer Facets Identification of Base Structure — Rear
Surface
13
Surface
18
Surface
19
Surface
17
Surface
19
Surface
12
Surface Surface
14
1 177
Rear Geometric Surfaces — Isometric View Scale NTS
Surface
15
16
129 CMA Tower Riyadh, Kingdom of Saudi Arabia
North Exterior Announcer Material Identification Material Identification Refer to Material Identification Section
A
B B B
B
C C D
C
E
A
1
Isometric for Material Identification â&#x20AC;&#x201D; Front Scale NTS
Laminated Tempered Glass Low iron starphire laminated tempered glass with ultra clear interlayers. All edges, exposed or unexposed to viewing, must be blemish-free and polished. Anti-glare finished. Color-treated Tempered Glass Glass to be chemically colored matching PMS 2607C (purple) and PMS 2945C (blue). All edges, exposed or unexposed to viewing, must be blemish-free and polished.
Logotype (Clear Varia Ecoresin XT) D Non-glare smooth finish exterior grade ecoresin. Optically clear. Bevel and finish all edges. Fabricated dimensional letters. Bevel and finish all edges.
E
178
Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish.
A
2 178
Isometric for Material Identification â&#x20AC;&#x201D; Rear Scale NTS
Logotype (Aluminum) Aluminum cut out letters applied directly on clear resin dimensional letters.
MAT
SS
MAT
LT
MAT
CT
MAT
CV
MAT
AL
130 CMA Tower Riyadh, Kingdom of Saudi Arabia
North Exterior Announcer Measurements, Descriptions, and Construction Details Dimensional logo (see section on Exterior Announcer Logo)
5 Back Glass: 20mm
color-treated glass
Components of Logo Glass Display The creation of a weather-sealed cabinet to safely house the dimensional logo by using the basic components as listed in order below. Guide Rail Guide Rail: Stainless steel rail to secure (using additional fasteners) the front glass, side glass, and back glass together as a single, rigid structure. Seal to resist from weather and other exterior elements
4
2
Spot lights inset within cavity structure; actual number of units may vary; refer to lighting consultant. Option to use kinetic I-cove lighting if space is constrained
Laminated Glass: 1 13mm clear laminated glass
Viewing Direction
Area of glass that inset in base structure
1 179
Isometric View of Glass Layering Scale NTS
3 Side Glass:
13mm clear laminated glass; comprised of two panes of glass with miter joint forming the angular tip at top
Stainless steel structure
200
Side Detail Scale 1:10
1
115
Logo
Logo
Back glass
Front glass
Side sealer glass
2
Scale 1:1
Internal support structure (consult structural engineer for exact construction)
5mm stainless steel exterior skin
Spot Light Option to use Color Kinetics I-cove if space is constrained
Open cavity for lights; approximately 400mm deep and 115mm wide
Open to ground for electrical
Anchor bolts; number of units TBD by structural engineer
Open space
Bevel
Side View of Bevel Detail
Sealer guide rail
180
2
Beveling Slightly bevel and smooth finish all exposed edges of glass. Inset at least 2mm for bevels.
North Exterior Announcer
180
Allow space for supporting electrical components
Open space
5mm stainless steel exterior skin
95
Viewing Direction
2
180
131
CMA Tower Riyadh, Kingdom of Saudi Arabia
Section View
132 CMA Tower Riyadh, Kingdom of Saudi Arabia
North Exterior Announcer Measurements, Descriptions, and Construction Details
Sealer guide rail Sealant; weather-sealed seams in glass 13
24
75
10
24
5
20
Miter cut sealer guide rail and glass for exact fit Fasteners
Back glass (shaded)
Drilled opening in glass Front glass
Stainless steel fastener (install flush to surface of glass)
Back glass
Fasteners
Weather-sealed seams
Sealer guide rail (stainless steel)
Side sealer glass; with the ends of glass panes inset/secure into sealer guide rail
Metal guide rail
Viewing Direction
Weather-sealed seams Side sealer glass
Front glass
Stainless steel fastener (install flush to surface of guide rail)
1 181
Side Detail Scale 1:3
2 181
Detail in Isometric View Scale NTS
133
North Exterior Announcer
CMA Tower Riyadh, Kingdom of Saudi Arabia
Measurements, Descriptions, and Construction Details
3
186
2
186
1
186
3
185
2
185
1
185
1 183
Indication of Section View â&#x20AC;&#x201D; Front Scale 1:20
134 CMA Tower Riyadh, Kingdom of Saudi Arabia
North Exterior Announcer Measurements, Descriptions, and Construction Details
Viewing Direction
3
186
Logo
2
186
1
186
3
185
2
185
1
185
1 184
Indication of Section View â&#x20AC;&#x201D; Side Scale 1:20
2 184
Indication of Section Cuts in Isometric View Scale NTS
135 CMA Tower Riyadh, Kingdom of Saudi Arabia
North Exterior Announcer Section Views
Structure Footprint
1 185
2 185
3 185
Section View Scale 1:20
Section View Scale 1:20
Section View Scale 1:20
136
North Exterior Announcer Section Views
1 186
2 186
3 186
Section View Scale 1:20
Section View Scale 1:20
Section View Scale 1:20
CMA Tower Riyadh, Kingdom of Saudi Arabia
137 CMA Tower Riyadh, Kingdom of Saudi Arabia
North Exterior Announcer Base Structure Facets Measurements
Plan View of Upper Platform 815
Footprint
605
492
441
1257
57 51
264
75
19 3
2
Plan View — Plane of Upper Platform (Measurements)
187
283
206
59
20
50
206
20
1
Footprint
948
Plan View — Plane of Upper Platform (Measurements)
187
Scale 1:30
Scale 1:30
Footprint of Base Structure 1619
371
680 1034
Plan View — Footprint of Base Structure (Measurements) Scale 1:30
215
880
4 187
343
579
436
751
3
573
193
17 7
187
436
2
414
276
25
206
111
159
1671
724
Plan View — Footprint of Base Structure (Measurements) Scale 1:30
138 CMA Tower Riyadh, Kingdom of Saudi Arabia
North Exterior Announcer Access Panels for Service and Maintenance
Viewing Direction
Side Access Panel (left)
Side Access Panel (right)
Note: Weather-proof seal all exposed edges on all detachable components Main Access Panel
Note: Weather-proof seal at edges
Note: Make accessible to light source; create detachable parts for access
1 188
Rear Isometric View Scale NTS
2 188
Front Isometric View Scale NTS
139 CMA Tower Riyadh, Kingdom of Saudi Arabia
North Exterior Announcer Measurements, Descriptions, and Construction Details 10
Fasteners
10
Guide rail and fasteners to match material and finish of base structure. Fasteners to flush with attaching surfaces and integrate fasteners inconspicuously into the overall design of the guide rail and glass panes. Illustration below shows the preferred, four rows/two fasteners per row (total of eight) arrangement only if structurally feasible. If an increase of fasteners is necessary, space out equally from top to bottom. Mirror details for the rear of the structure.
2
190
48 Guide rail
48 Position of fastener
Position of fastener Fastener Row 1 Guide rail
eq.
Row 1
Fastener Row 2
5
5
eq.
Fastener Row 3
eq.
Fastener Row 4
2 190
Detail Vew Scale 1:4
Fasteners install flush / close to flush to glass surface. Weather-proof lining to seal. Approximately 10mm in diameter, decrease diameter size to minimum if possible.
Weather-proof seal lining (clear or neutral color preferred)
Glass pane
3
1
Front View
190
Scale 1:20
190
Fasterner Installation Detail Scale 1:1
140 CMA Tower Riyadh, Kingdom of Saudi Arabia
Internal Support Structure North and South Announcers
Internal Support Structure for North and South Announcers The shape of the internal structure follows the basic shape of the base structure. Support structure must fit within the interior spaces of the structure and be completely hidden from view. Attach the exterior skin to the internal support structure using stainless steel beams at strategic locations. Anchor structure to ground and provide additional fasteners to secure exterior skin independently. Constructed from stainless steel (non-corrosive) and must have the capacity to support the vertical and horizontal weight of the entire structure. Consult structural engineer for calculations and final design of the structure.
Internal Support Structure
Internal Support Structure
Height of structure to clear depth of light cavity Additional anchors for securing position of external skin
Anchor structure to ground
1 191
Internal Support Structure â&#x20AC;&#x201D; Front View Scale 1:25
2 191
Isometric of Internal Support Structure Scale NTS
141 CMA Tower Riyadh, Kingdom of Saudi Arabia
External Illumination North Announcer
External Illumination Use spot lighting to illuminate the structure at times of low availability of ambient light. Ground base, low profile, spot lighting units are preferrable. Position the lights angled as illustrated below to draw out the shadows and highlights created by the facets for maximum visual impact. Light output at approximately 6000K preferred. Consult lighting
Tile 800mm x 400mm
designer for details.
Sign structure to be situated within an area of 4000mm x 800mm
Low profile, ground installed lighting Light
1 192
Plan View Placement of External Illumination Scale 1:30
2
Side View
192
Scale 1:30
Prioritize light spread to focus mainly at the base structure; upper portion of the sign is internally illuminated
142 CMA Tower Riyadh, Kingdom of Saudi Arabia
South Announcer Measurements, Descriptions, and Construction Details Design Intent
1477
Highest quality materials and utmost level of workmanship required in the fabrication of the sign’s structure. Serves as premier entry marker, sign’s primary purpose is to “present” the tower’s logo in a regal, prestigious, and attractive way. The intent is to exemplify the crystalline quality of a gem stone unearthed from the ground. Note: The basic design of North and South Announcers are mirrored (with the exception of the logo) and share identical fabrication details/materials. Reference details of North Announcer when fabricating this sign.
Fabrication Notes & Requirements Parts and components must be made to fit with minimum amount and size (>1mm of opening seams) of visible seams. The choice of materials must be weather resistant and durable under local weather conditions. UV coating (to resist color fading) and non-glare coating on glass, acrylic, and other reflective surfaces is highly recommended. Use non-corrosive metal alloys but stainless steel is preferrable as the main building material.
1003
2480
Area for Logo Logo TBD / choose option of logo suitable for horizontal layout
Internal / External Lighting Use “cool white” light source at 6000K range. Consult lighting designer / electrician for approval on details prior to fabrication. Color-treated Glass Reference section on Color Specifications on Glass for details.
4000
1
Front View
193
Scale 1:20
Structural Consult structural engineer for approval on details prior to fabrication.
143 CMA Tower Riyadh, Kingdom of Saudi Arabia
South Announcer Measurements, Descriptions, and Construction Details
2363
1477
156
2480
Viewing Direction 18
1003
20
578
1 194
Left Side View Scale 1:20
4000
2
Rear View
194
Scale 1:20
144 CMA Tower Riyadh, Kingdom of Saudi Arabia
External Illumination South Announcer
External Illumination Use spot lighting to illuminate the structure at times of low availability of ambient light. Ground base, low profile, spot lighting units are preferrable. Position the lights angled as illustrated below to draw out the shadows and highlights created by the facets for maximum visual impact. Light output at approximately 6000K preferred. Consult lighting
Tile 800mm x 400mm
designer for details.
Sign structure to be situated within an area of 4000mm x 800mm
Low profile, ground installed lighting Light
1 195
Plan View Placement of External Illumination Scale 1:30
2
Side View
195
Scale 1:30
Prioritize light spread to focus mainly at the base structure; upper portion of the sign is internally illuminated
145 CMA Tower Riyadh, Kingdom of Saudi Arabia
Plaza Announcer Measurements, Descriptions, and Construction Details Measurements in millimeters
Design Intent
1
198
One of the first signs to be seen as one arrives at one of the tower’s main entrances. Highest quality materials and utmost level of workmanship is required in the fabrication of the sign’s structure as the sign’s primary purpose is to “present” the tower’s logo in a regal, prestigious, and attractive way. The inspiration is taken from a precious gem stone unearthed from the ground, therefore, a portion of the sign is embedded in the ground.
3060
Area for Logo Logo TBD (approximately 40mm border around edges); choose option of logo suitable for horizontal layout
490
1375
2937
1185
The total height of 3060mm is calculated with the 10mm base plate
Fabrication Notes & Requirements Parts and components must be made to fit with minimum amount and size (>1mm of opening seams) of visible seams. The choice of materials must be weather resistant and durable under local weather conditions. UV coating (to resist fading) and non-glare coating on glass, acrylic, and other reflective surfaces is highly recommended. Use non-corrosive metal alloys but stainless steel is preferrable as the main building material. Use flexible seals or cushion at seams whenever possible to resist expansions and contractions at joints. Internal Lighting Consult lighting designer / electrician for specifications. External Lighting Consult lighting designer / electrician for specifications. Color-treated Glass Use a fade-resistant color process. For color accuracy, see specification on color-treated glass.
4800
1
Front View
196
Scale 1:25
Structural Consult structural engineer for review prior to fabrication.
146 CMA Tower Riyadh, Kingdom of Saudi Arabia
Plaza Announcer Measurements, Descriptions, and Construction Details
65
Viewing Direction
Viewing Direction
3060
1685
The total height of 3060mm is calculated with the 10mm base plate
800
1 197
Right Side View Scale 1:25
2
Rear View
3
197
Scale 1:25
197
Left Side View Scale 1:25
3050
Open space
Open space
LED units
Color-treated glass
Front View Scale 1:10
1
Open space
Open space
Seal
10mm stainless steel base plate
Anchor bolts; lift structure off the ground by 10mm to allow for air circulation. Number of bolts TBD by structural engineer
Internal support structure (consult structural engineer for exact construction)
3mm stainless steel exterior skin
LED lighting: Color Kinetics I-Cove lighting. Final specifications TBD by lighting designer
Flexible seals used around edge of glass permitting thermo expansion of glass
Structure
Glass
Open cavity for lights; approximately 150mm deep and 115mm wide
Logo (see section on logo buildup)
Viewing Direction
Plaza Announcer
198
20
Open space
150
3mm stainless steel exterior skin
147
CMA Tower Riyadh, Kingdom of Saudi Arabia
Measurements, Descriptions, and Construction Details
20
148 CMA Tower Riyadh, Kingdom of Saudi Arabia
Plaza Announcer Measurements, Descriptions, and Construction Details
Fasteners
60
60
Ground embedment graphics with internal illumination
Metal crossing with etched pattern
Exposed fastener
60 400
2000 60
Announcer structure Viewing Direction
1
Plan View
199
Scale 1:25
800
571
448
60mm wide metal cover
149 CMA Tower Riyadh, Kingdom of Saudi Arabia
Plaza Announcer Measurements, Descriptions, and Construction Details 523
823
823
Surface
5
Surface
3
655
711
1
1375
Surface
Surface
2
523
Surface
Surface
4
6
1194
452
2169
Surface
7
1 200
Geometric Surfaces â&#x20AC;&#x201D; Base Structure (Front View) Scale 1:25
Surface
8
150 CMA Tower Riyadh, Kingdom of Saudi Arabia
Plaza Announcer Measurements, Descriptions, and Construction Details
2936 1126
1810
Upper Platform
Surface
Surface
13
1024
10
Surface
Surface
9
11
Surface
Surface
12
Surface
14
15
Footprint
878
142
1119
1330
4800
1 201
Geometric Surfaces â&#x20AC;&#x201D; Base Structure (Front View) Scale 1:25
802
529
151 CMA Tower Riyadh, Kingdom of Saudi Arabia
Plaza Announcer Measurements, Descriptions, and Construction Details
Surface
3
Surface
5
Surface
1
Surface
6
Surface
2
Surface Surface
2
4
8
FS
Surface
7
3
FS
Surface Surface
9
1 202
Geometric Surfaces â&#x20AC;&#x201D; Base Structure (Front View) Scale 1:25
10
Surface Surface
11
Surface
12
Surface
13
Surface
14
15
152 CMA Tower Riyadh, Kingdom of Saudi Arabia
Plaza Announcer Measurements, Descriptions, and Construction Details
2894
673
1233
Surface
19
Surface
Surface
17
Surface
Surface
16
Surface
18
22
1472
1654
4800
1 203
Geometric Surfaces â&#x20AC;&#x201D; Rear View Scale 1:25
1652
20
Surface
384
21
1290
153 CMA Tower Riyadh, Kingdom of Saudi Arabia
Plaza Announcer Measurements, Descriptions, and Construction Details
Surface
19
Surface
Surface
Surface
21
17
8
Surface
20
Surface Surface
18
Surface
16
1 204
Geometric Surfaces â&#x20AC;&#x201D; Rear View Scale 1:25
22
Surface
7
154 CMA Tower Riyadh, Kingdom of Saudi Arabia
Plaza Announcer Material Identification A
Material Identification Refer to Material Identification Section
A
B
B
B
C
(see section on Ground Embedment)
C B
A
B
C
Logo (Clear Resin and Aluminum) See section on Dimensional Logo A
1 205
Isometric for Material Identification â&#x20AC;&#x201D; Front Scale NTS
Laminated Tempered Glass Low iron starphire laminated tempered glass with ultra clear interlayers. All edges, exposed or unexposed to viewing, must be blemish-free and polished. Non-glare finish. Color-treated Tempered Glass Glass to be chemically colored matching PMS 2607C (purple) and PMS 2945C (blue). All edges, exposed or unexposed to viewing, must be blemish-free and polished.
Logotype (Clear Varia Ecoresin XT) D Non-glare smooth finish exterior grade ecoresin. Optically clear. Bevel and finish all edges. Fabricated dimensional letters. Bevel and finish all edges.
E
A
Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish.
Logotype (Aluminum) Aluminum cut out letters applied directly on clear resin dimensional letters.
MAT
SS
MAT
LT
MAT
CT
MAT
CV
MAT
SS
155 CMA Tower Riyadh, Kingdom of Saudi Arabia
Plaza Announcer Material Identification Material Identification Refer to Material Identification Section
A
B
A
A C
B B
C
(see section on Ground Embedment)
D
A
1 206
Isometric for Material Identification â&#x20AC;&#x201D; Rear Scale NTS
B
C
(see section on Ground Embedment)
Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish. Laminated Tempered Glass Low iron starphire laminated tempered glass with ultra clear interlayers. All edges, exposed or unexposed to viewing, must be blemish-free and polished. Color-treated Tempered Glass Glass to be chemically colored matching PMS 274C (purple) and PMS 300C (blue). All edges, exposed or unexposed to viewing, must be blemish-free and polished.
D Structure Surface Stainless steel marine grade type 316 with satin, medium horizontal brush finish.
Faceted crystalline pattern to be etched and filled on stainless steel structure (see section of Faceted Crystalline Pattern for details).
MAT
SS
MAT
LT
MAT
CT
MAT
SS
MAT
EG
156
Plaza Announcer
CMA Tower Riyadh, Kingdom of Saudi Arabia
Measurements, Descriptions, and Construction Details
3
211
2
211
1
211
3
210
2
210
1
210
3
209
2
209
1
209
1 207
Indication of Section View â&#x20AC;&#x201D; Front Scale 1:25
157 CMA Tower Riyadh, Kingdom of Saudi Arabia
Plaza Announcer Measurements, Descriptions, and Construction Details
3
211
Viewing Direction
2
211
1
211
3
210
2
210
1
210
3
209
2
209
1
209
1 208
Indication of Section View â&#x20AC;&#x201D; Side Scale 1:25
2 208
Indication of Section Cuts in Isometric View Scale 1:25
158 CMA Tower Riyadh, Kingdom of Saudi Arabia
Plaza Announcer Section Views
Structure Footprint
1 209
Section View Scale 1:25
Open Space
2 209
Section View Scale 1:25
Open Space
3 209
Section View Scale 1:25
159 CMA Tower Riyadh, Kingdom of Saudi Arabia
Plaza Announcer Section Views
1 210
Section View Scale 1:25
Upper platform
Open cavity for internal illumination
2 210
3 210
Section View Scale 1:25
Section View Scale 1:25
160
Plaza Announcer Section Views
1 211
2 211
3 211
Section View Scale 1:25
Section View Scale 1:25
Section View Scale 1:25
CMA Tower Riyadh, Kingdom of Saudi Arabia
161 CMA Tower Riyadh, Kingdom of Saudi Arabia
Plaza Announcer Base Structure Facets Measurements
Plan View of Upper Platform
Footprint 952
435
235
420
3 69
2
Plan View — Plane of Upper Platform (Measurements)
212
Scale 1:35
Footprint of Base Structure
Plan View — Plane of Upper Platform (Measurements) Scale 1:35
1654
13 0 0
1862 158
198
448
5 32 11 3 6
3
Plan View — Footprint of Base Structure (Measurements) Scale 1:35
545
71
887
650
800
802
571
602
142
212
46
92
222
377
391
428
428
383
1801
154
1
360
360
360
533
1126
212
Footprint
13 39
4 212
Plan View — Footprint of Base Structure (Measurements) Scale 1:35
162 CMA Tower Riyadh, Kingdom of Saudi Arabia
Plaza Announcer Details of Ground Embedment 1162
3638
Area of open glass
Note: Numbers provided in drawing are measurements based on calculations; obtain/use true measurements using prototype or field measurements of fabricated structure when necessary. 825
Seam cover, 60mm width; inset from the outer edges
890
1868
1769
2154
Metallic cross beam
400
2158
1
217
280
60
60
60
Area of open glass
60
2619
2751
791 928
Match exactly to adjacent contour of footprint of base structure
1
215
158 1291
1
Plan View
213
Scale 1:15
1655
1854
163 CMA Tower Riyadh, Kingdom of Saudi Arabia
Plaza Announcer Ground Embedment Layering Details
Metal cover for sealing off gaps between ground glass elements
Laminated tempered glass with adequate rigidity to support pedestrian traffic above
Ground
Color-treated laminated tempered glass
Exposed metallic cross beam LED lights
In-ground embedment (see section on Ground Embedment)
Below ground
1 214
Isometric for Material Identification â&#x20AC;&#x201D; Rear View Scale NTS
2 214
Basic Compositional Layers of Ground Embedment Scale NTS
164 CMA Tower Riyadh, Kingdom of Saudi Arabia
Plaza Announcer Section View of Ground Embedment
60
A
35 15
15
A
Top Glass Panel Clear laminated glass. Glass material must be tolerant to exterior weather conditions and impact from pedestrian traffic.
B
Inside Glass Panel 10mm color-treated, laminated glass.
C
Seam Cover Stainless steel construction to protect and hide glass fasteners from view. Angle shaved at ends.
D
Horizontal Spacers Semi-rigid spacer for absorption of shock and impact in the spaces between glass and metal. Slight perforations at some points in seal as vent.
E
Sealant Layer of flexible, waterproof rubber or silicone seal to prevent the entry of water and debris into the interior of ground embedment. Compressed by seam cover from above.
F
Seam Cover Fastener Flexible to allow tension to hold seam cover in place; also to protect the adjacent edges of the top glass.
G
Electrical and LED Components Area for additional electrical devices and supporting electrical components.
H
Ground Tray Stainless steel compartment to separate electric components from ground.
I
Glass Fastener Stainless steel rod fastening all layers of materials together; top of fasteners to flush with the ground and not interfere with the seam cover.
J
LED Diode Aim light upward towards the glass panels. Neutral color output. Quantity and arrangement of diodes TBD by lighting designer.
K
Supporting Platform Structure This stainless steel structure provides a platform for the fasteners to secure to and act as support structure to the weight of glass panels.
L
Anchor Fasteners Secure ground tray to the ground.
M
Ground
3
C
30
2
E
5
10
F
D
58
D
I 35
B M
120
J
K 47
H
3
G
L H
1 215
Section View Scale 1:2
M
165 CMA Tower Riyadh, Kingdom of Saudi Arabia
Plaza Announcer Isometric View of Ground Embedment
F
A
I C
E
I
B
I
D D K
G M
H M
1 216
Isometric Section View Scale NTS
H
J
166 CMA Tower Riyadh, Kingdom of Saudi Arabia
Plaza Announcer Access Panels
Side Access Panel (left)
Side Access Panel (left)
Note: Make accessible to light source; create detachable parts for access
Side Access Panel (right)
Note: Weather-proof seal all exposed edges on all detachable components
Side Access Panel (right)
Note: Weather-proof seal at edges
Rear Access Panel
Bottom edge to clear components of ground embedment (allow approximately 3mm clearance)
1 218
Isometric for Material Identification â&#x20AC;&#x201D; Rear View Scale NTS
2 218
Basic Compositional Layers of Ground Embedment Scale NTS
167 CMA Tower Riyadh, Kingdom of Saudi Arabia
Plaza Announcer Internal Support Structure
Welded connection
Internal Support Structure The shape of the internal structure follows the basic shape of the base structure. Constructed from stainless steel and constructed with the capacity to support the weight of the structure. Hidden from view and the entirety of the support structure is contained within the interior space of the exterior skin.
Internal Support Structure
Internal Support Structure
Upper platform
Upper platform aligns with the top of the logo display Silhouette of exterior skin
Silhouette of exterior skin
Base plate Additional anchors for securing position of external skin
Anchor structure to ground
1 219
Internal Support Structure â&#x20AC;&#x201D; Front View Scale 1:30
Base plate
2 219
Indication of Section View â&#x20AC;&#x201D; Front Scale 1:30
168 CMA Tower Riyadh, Kingdom of Saudi Arabia
Plaza Announcer Backlighting Components Details
End Cap (left) Weather-sealed. Fasten and lock to sign structure
Color-treated Tempered Glass Fasten and secure to sign structure
Insert LED components into space behind color-treated glass
Position dimensional logo in front of color-treated glass; center align within space
1 220
Backlighting Components Scale NTS
LED Columns Framework Backlighting color-treated glass and logo. Arrange diodes for evenly distributed light, quantity TBD by lighting designer. Attach diodes to framework and install on sliding tracks for ease of replacement. LED shall also be accessed from rear of framework.
End Cap (right) Weather-sealed. Fasten and lock to sign structure
169 CMA Tower Riyadh, Kingdom of Saudi Arabia
Plaza Announcer Backlighting Components Details
307 13
20
70
2 40
Allow 20mm inset
20 115
Framework for LED units LED units
Open space
eq.
Clear tempered glass
490
Open space
Aluminum plate (in form of logo shape)
2
Color-treated tempered tlass eq.
221
Viewing Direction
Clear acrylic (in form of logo shape)
20
LED framework
Viewing Direction
258
1
Side View
2
221
Scale 1:25
221
Backlighting and Logo Layering â&#x20AC;&#x201D; Side View Scale 1:8
Allow 20mm inset
170 CMA Tower Riyadh, Kingdom of Saudi Arabia
Plaza Announcer Glass and Cross Beam Details
3
222
Ground embedment
Base Color (CMA brand color)
PMS 2945
Structure
Reduce color intensity to 25% of full value to retain translucency of glass. Color is intended to be a tint of the original base color. CMYK combo: C 100 / M 45 / Y 0 / K 14
2 222
Plan View of Plaza Announcer Scale NTS
Color Transition (65% PMS 2607)
Etched graphic
Base Color
PMS 2607
Etched graphic
Cross beam
Reduce color intensity to 25% of full value to retain translucency of glass. Color is intended to be a tint of the original base color. CMYK combo: C 81/ M 100 / Y 0 / K 7 280
Cross Beam with Etched Graphic Faceted pattern to be etched at least 1mm in depth and filled with gray matching PMS Cool Gray 11C. Created by diagonal and intersecting angular lines forming faceted, polygonal geometry.
1 222
Front View Scale NTS
3 222
Ground Embedment Cross Beam Graphic Scale NTS
171 CMA Tower Riyadh, Kingdom of Saudi Arabia
Plaza Announcer Ventilation Details Rear of structure
Note: Consult structural engineer for final specification
Guard Plate Secondary Vent
Air path
Additional vent opening located at the upper portion of sign
Pin hole perforations in stainless steel plate. Position inboard within the footprint of the structure
Air Duct Connecting the two compartments of ground embedment. Provide a release for trapped moisture or heated air. Note: Install small grade mesh to prevent insects from entering structure
Air path
Base Plate
Include small perforations of >2mm to allow air from interior of structure to exit throught main vent
Main Vent Structure lifted off ground with 10mm clearance for air to exit structure and ground embedment. Follows the contour of the footprint
10 Ground
Embedment
Bolt Air duct with valve Ground tray
Drainage for rain water / moisture
Level Vent
1 223
Air Escape Path â&#x20AC;&#x201D; Rear View Scale NTS
Ground
2 223
Detail of Main Vent at Base of Structure Scale 1:2
172 CMA Tower Riyadh, Kingdom of Saudi Arabia
External Illumination South Announcer
External Illumination Use spot lighting to illuminate the structure at times of low availability of ambient light. Ground base, low profile, spot lighting units are preferrable. Position the lights angled as illustrated below to draw out the shadows and highlights created by the facets for maximum
Tile 800mm x 400mm
visual impact. Light output at approximately 6000K preferred. Consult lighting designer for details.
Allow light spread to reach the full height of the structure
Ground embedment
Cross beam to match tile height of 400mm
Sign structure to be situated within an area of 4800mm x 800mm
Low profile, ground installed lighting
1 195
Plan View Placement of External Illumination Scale 1:30
Light
2
Side View
195
Scale 1:30
173 CMA Tower Riyadh, Kingdom of Saudi Arabia
Dimensional Logo Build-Up of Dimensional Logo for North, South, and Plaza Announcer
Color-treated glass UV rated epoxy adhesive bonded
Metal face
Clear acrylic
Clear plastic resin (resistant to yellowing in sunlight)
Viewing Direction
Attach to acrylic using UV resistant epoxy adhesives
2 226
Sample Detail of Logo Layering Scale NTS
2
40
Metal face (aluminum) Color-treated Glass
Viewing Direction
Metal face
Viewing Direction
Viewing Direction
Clear plastic resin
Note: Final logo to be determined. Illustration is for placement only. Do not fabricate until logo is finalized by CMA.
1 226
Isometric View of Logo Build-Up Scale NTS
Light Source
3
Side View
226
Scale 1:3
174 CMA Tower Riyadh, Kingdom of Saudi Arabia
Specifications on Color-treated Glass North, South, and Plaza Announcer
Base Color (CMA brand color) Base Color (CMA brand color)
PMS 2945
PMS 2945
Viewable Portion
Reduce color intensity to 25% of full value to retain translucency of glass. Color is intended to be a tint of the original base color. CMYK combo: C 100 / M 45 / Y 0 / K 14
Reduce color intensity to 25% of full value to retain translucency of glass. Color is intended to be a tint of the original base color. CMYK combo: C 100 / M 45 / Y 0 / K 14
Color Transition (55% PMS 2607)
Ground Embedment Fabricate glass as one continuous piece and install as separate pieces to ensure smooth color gradation
Base Color
PMS 2607 Reduce color intensity to 25% of full value to retain translucency of glass. Color is intended to be a tint of the original base color. CMYK combo: C 81/ M 100 / Y 0 / K 7
1
North Announcer Glass Only — Front View
227
Scale 1:25 Base Color (CMA brand color)
PMS 2945 Reduce color intensity to 25% of full value to retain translucency of glass. Color is intended to be a tint of the original base color. CMYK combo: C 100 / M 45 / Y 0 / K 14
Viewable Portion
Color Transition (55% PMS 2607)
Sign Structure
Base Color
Base Color
PMS 2607
PMS 2607
Reduce color intensity to 25% of full value to retain translucency of glass. Color is intended to be a tint of the original base color. CMYK combo: C 81/ M 100 / Y 0 / K 7
2 227
South Announcer Glass Only — Front View Scale 1:25
Reduce color intensity to 25% of full value to retain translucency of glass. Color is intended to be a tint of the original base color. CMYK combo: C 81/ M 100 / Y 0 / K 7
3 227
Plaza Announcer ̶ Plan View Scale NTS
175
Credits Project Support
Acknowledgment
The HOK Visual Communications design team would like to thank our colleagues at HOK Advance Strategies, Architecture, & Interiors for their help in contributing to this effort. We also thank our consultants at Xibitz and JSAV for their insights on fabrication details and electronic media.
Individual Acknowledgment: Xibitz Chuck Plockmeyer JSAV Bill Schuermann Lerch Bates, Inc. Joe Bledsoe HOK John Bellian (Arch), Ryan Favier (Interior), Kevin Shumbera (Arch), Michael Valenzuela (Arch)
CMA Tower Riyadh, Kingdom of Saudi Arabia
Managing Complexity Through Visual Communications HOK Visual Communications can strategically plan and design the appropriate vehicle to convey your message, package your information, position your image, or promote your product. Our client experience is broad in scope and international in reach. We offer deep, knowledgeable expertise in communicating about all aspects of the built environment. We seek functional, aesthetic, and economic solutions that are flexible and durable and we fully understand the business implications of good design. Image and Identity Planning Information Media Wayfinding and Architectural Graphics Display Environments
HOK VISUAL COMMUNICATIONS 2 800 P OS T OA K BO U L E VA R D | SUIT E 3700 HO US TO N | T E X AS | 7 7056 | USA +1 7 13 407 7 700 | HO K .CO M