The Ohio State University Medical Center

Page 1

WAY F I N D I N G , S I G N S Y S T E M S A N D G R A P H I C D I S P L AY S R EG A R D I N G P R O J EC T O N E O H I O S TAT E U N I V E R S I T Y M E D I C A L C E N T E R D E S I G N D E V E L O P M E N T D O C U M E N TAT I O N — 10 0 % COLUMBUS | OHIO

10.2010


2

Overview

Ohio State University Medical Center Columbus | Ohio

Wayfinding, Sign Systems and Graphic Displays Summary

The following pages illustrate the known wayfinding media likely to be needed in the evolving design of this facility. Knowing that digital signage and electronic displays are specified by others, this scheme focuses on the passive messages inside the environment. The plaques and pylons that offer these messages are purposefully minimalist to align with the modernist interior design. The design intent: A modular family of signtypes deployed in a consistent material and repetitive in location. Clean, minimalist, consistent.

10.2010


3

Overview

Ohio State University Medical Center Columbus | Ohio

Wayfinding, Sign Systems and Graphic Displays Included In This Package

Exclusions

Exterior Building Signage — Includes signs attached to the building such as logo identification.

Below is a list of signage related items that are NOT addressed as part of this document:

All other site signage is understood to be designed and administered by the landscape architect.

Labeling of pipes, conduits, control panels, etc. Typically addressed by the specialty contractor for each system (medical gases, water pipes, etc.)

Illuminated emergency exit signs

Emergency communications devices identification and instructions

Fire extinguisher and hose reel identification

Building PA system (firefighter instructions)

Fire annunciation panel messages

Fire Department connections

Lobby identification signs (logo and/or letters)

Firefighter air system refill station identification and instructions

Lobby/level directories

Automated external defibrillators (AEDs)

Elevator lobby level informational signs

Enhanced graphics (murals, displays, custom artwork, banners, large wall graphics)

Overhead informational/directional signs

Exterior site signage design or coordination

Wall mounted directional signs

Shell space build out services (after the building bid documents have been issued)

Patient room signs

Temporary signage required due to phasing/scheduling

Department identification signs

Donor recognition, corner stone graphics, time capsules or other similar specialty items

Suite/tenant identification signs (labs, diagnostics, etc.)

Specialty food service or cafeteria signage

Base building core signage (ADA required signs, restrooms, stairs, mechanical)

Marketing/advertising promotional materials design (print or on-screen graphics)

Life safety signs (warning signs, stairwell signs, egress information)

Sign permits (obtaining all required permits shall the responsibility of the sign contractor)

Room/office identification signage

Amenities signs (reception, nurse’s station, cafeteria name display)

Informational signs (patient instructions)

Interior regulatory signs (bio-hazard, do not enter, radiation, x-ray, no smoking)

Iconic art and symbol development

Building identification letters and logos (emergency canopy, entrance drop-offs, etc.)

Entrance information signs (address, no smoking, policies)

Interior Signage Standards Program — Includes the development of a comprehensive interior signage program to address all typical interior signage room identification, informational and wayfinding signage requirements. •

10.2010


4

Quantity Estimate

Ohio State University Medical Center Columbus | Ohio

Interior and Exterior Signage Estimate

OSUMC — Sign Quantities Estimate Design Development Submittal — July 16, 2010 Revised — October 15, 2010

Interior Signage

Interior Signage (Cont.)

SIGNTYPE

DESCRIPTION

QUANTITY

SIGNTYPE

DESCRIPTION

QUANTITY

FL

Freestanding Directional Large

16

SI

Stair Identification (corridor side identification)

69

FS

Freestanding Directional

18

SS

Stair Signs (lifesafety information inside stairwell)

69

FM

Freestanding Map

10

EL

Elevator Landing Signs

136

LB

Location Beacon

60

RS

Restroom Signs

136

TM

Table Map

12

TE

Tactile Exit Signs

12

WD

Wall Mounted Directionals

245

AR

Area of Refuge

TBD

SW

Small Wall Mounted Directionals

260

TC

Two-Way Communication

29

WM

Wall Mounted Map

45

SL

Stairway Level Markers

73

FO

Floor Overview

18

OS

Occupant Load Signs

13

DD

Double Door Identification

355

NE

Tactile No Exit Signs

11

OD

Overhead Directional

145

DE

Delayed Egress Door Signs

8

LO

Large Overhead Directional

67

PD

Powered Door Leaf Signs

34

PA

Perpendicular Announcer

172

MS

Movable Stanchion

19

Building Signage / Exterior Signage

HR

Horizontal Rule Letters

28

PP

Perpendicular Pictogram

131

CP

Corner Mounted Pictogram

61

CD

Corner Mounted Directional

DS

Door Mounted Safety Information

RN

DESCRIPTION

QUANTITY

PL

Primary Logo Identification Sign (Illuminated — South Facade)

1

PW

Primary Logo Identification Sign and Building Name (Illuminated — West Facade) 1

35

BN

Building Name Identification Sign (Illuminated — South Facade)

1

592

EE

Emergency Identification Sign (Illuminated — North Facade)

1

Room Number (only—closets, mechanical, etc.)

370

TC

Street Level Building Name Identification Sign (Illuminated)

2

RI / RRI*

Room Insert (room number with room function description insert)

670

SA

Street Address Numbers (Non-Illuminated)

4

PR

Patient Room Identification

300

VG

Graphics at Building Entry (Non-Illuminated)

4

IH**

Insert Holders

50

IL**

Large Insert Holders

50

*Use Retrofitted Room Sign (RRI) as an option in place of RI; added after Oct 15 Design Review

**Added after Oct 15 Design Review

10.2010


5

Introductory Notes to CD Development

Ohio State University Medical Center Columbus | Ohio

Finalization of DD Phase Design Review Oct. 2010

Cost

Epidemiology

It is the desire of the design team to retain the use of 3Form Chroma ® for larger, free standing signage,

It is compatible to use 3M Phenolic Cleaner on 3F Chroma ® surfaces. A 7 Day Full Immersion Test was

while smaller, code required signage will use a similar but less costly material as substitute — 3Form

performed and no compatibility problems were found. However, minor staining of the 3F Chroma ® maybe

EcoResin. Furthermore, additional savings are realized in the reduction of material use with revised

visible due to the cleaner’s natural amber hue, which can be easily removed by renewing 3F Chroma ®

specifications of thinner gauges throughout the document. We feel that by making the aforementioned

surface. It is important to note that the 7 Day Full Immersion Test is a fairly substantial compatibility test

changes will reduce costs dramatically without eroding the overall aesthetics of the wayfinding program.

and sometimes will show results that will not be encountered under normal circumstances. Other hospital

However, if further cost cutting is necessary, three alternate material sets are proposed on page 17 with

grade disinfectants tested for compatibility with 3F Chroma ® include: Precise, Dispatch, and Virex II

the intention of gradually lowering cost per sign to meet targeted budget allowance. It is a reminder that excessive cost cutting can negatively impact the quality of the program.

For detailed information, contact 3Form representatives below: Donyce Rich — donyce.rich@3-form.com

Operational Usability

Charles Moore — charles.moore@3-form.com

• Room Insert signs (RRI) revised to match existing design and usability standards • Inserts sizes standardized to quarter page 8.5" x 11" letter size on sign type RRI. • Patient advisories window added to sign type RRI. • See notes on extension of sign type WD and SW on page 36. Color Coding It has been decided to eliminate the use of color bar in the wayfinding system of ProjectOne due to the fact a color coding strategy has not been successfully implemented by OSU. It is a concern that the addition of colors as a visual element on signs may potentially confuse a viewer. Moreover, assigning a unique and specific color per campus building presents an obstacle due to the limited number of identifiable colors. In response, the building name will be incorporated in the header display on large signs and the proposed

Additional Sign Types Sign type WM (Wall Mounted Map) can be used in place of FM (Free Standing Map) in situations where available floor spaces are limited or when an optimal location can not be located. Use wall mounted maps at next logical location or the nearest adjacent wall. Simple insert holders in two sizes as requested by OSU. See sign type IH (letter size) and IL (tabloid size). Typography OSU brand font — Whitney — is used for all wayfinding materials pertaining to ProjectOne. Otherwise, follow existing university typographic rules for all other buildings.

usage of building specific prefix on room signs.

Other Notes

ADA Standards

Unused sign types are purposefully preserved in the document for future references.

Sign types are drawn in compliance with ADA and other safety codes as of date of original issue. Reconfirm and update drawings to ADA standards prior to fabrication. Contact Scott Lisner, University ADA Coordinator for information.

Certain sign types in the wayfinding program are offered but may not be applicable to ProjectOne.

Set screws in construction are to be always omitted when fraction from tight tolerance of routed parts is adequate to secure panels in place. Providing functional prototype for approval prior to fabrication.

10.2010


6

Wayfinding Experience

Ohio State University Medical Center Columbus | Ohio

General Overview of Scale and Application

Exterior Building Mounted Landmark architecture, sign(s) on building

Interior Circulation

Lobby pylon wayfinding, exclusive material

Floor Arrival Departments and Rooms Dimensional logo and announcer behind main reception desk; Lobby entry experience

Public/Staff Restricted Areas

Restrooms, staff stations, warning icons and all other basic egress signage

Light box as visual totem offers directory/mapping messages; Lobby portals into ground floor functions

Dimensionally cut out names of department, function rooms

Overhead directional and entry announcers on hallways

Destination Legends

Overhead directional

Perpendicular wall mounted signage

Elevator lobby; elevator exchange; level indicators elevator jam tags

Mapping and directory (Freestanding optional)

Signs on building, graphics at entry

6 5

BUILDING NAME

4 INFORMATION

2 1 G

Basic egress, restrooms, and utility rooms signage

T H E JA M E S

T H E JA M E S

In Building Destination

T H E JA M E S

T H E JA M E S

In Building Destination

In Building Destination In Building Destination

In Building Destination

In Building Destination

In Building Destination

In Building Destination

In Building Destination

In Building Destination

Exam Room

Dimensional names of function rooms. Warning/hazard icons

T H E JA M E S

T H E JA M E S

Cut out letters

10.2010


7

Typography

Ohio State University Medical Center Columbus | Ohio

Brand Fonts and Usage

Whitney Font Family —Primary Narrative Typography

Whitney Medium

Whitney Light

ABCDEFG HIJ K L M N O P Q R ST UV W X Y Z abcdefghijklmnopqr stuv w x y z

ABCDEFGHIJK L MNOPQR ST UV W X YZ abcdefghijklmnopqrstuv w x yz

12 3 4 5 6789 0

123 4567890

Whitney Book

Whitney Semi Bold (Type Set for Extra Legibility)

ABCDEFGHIJK L MNOPQR ST UV W X Y Z abcdefghijklmnopqrstuv w x y z

ABCDE FG H IJ K L M NO P Q R STU V W X Y Z abcdef ghijklmnopqr stuv w x y z

12 3 4567890

12 3 4 5 67890

10.2010


8

Message Coding

Ohio State University Medical Center Columbus | Ohio

Visual Way-Training

We will use visual coding of signs to overcome visual clutter. We will see messages presented with a consistent color coding. Requires consistent look of message vehicles and message layouts — it is the coloration of codes.

Gray on White Messages to Public

Black on Yellow Caution Attention Messages

White on Gray Messages for Practitioners

Black on Orange Hazard Warning Messages

Red on White Life Safety Messages

Black on Green Equipment Requirement Messages

White on Red Life Safety Messages

Black on Blue Equipment Availability Messages

Modular size and consistent material will support a consistency in the visual vocabulary 10.2010


9

Pictograms

Ohio State University Medical Center Columbus | Ohio

References

RESTROOMS

Men

Elevator

Women

Patient elevator

Restroom

Accessibility

Automated elevator

Freight elevator

Stairs

Stairs up

Stairs down

EGRESS / SAFETY

Fire exit

Fire extinguisher

Fire alarm

No littering

No animals

Defibrillator

Area of Refuge

Exit

PROHIBITORY

No smoking

No phone

No food

No music

No pictures

BACK DIRECTIONAL

10.2010


10

Pictograms

Ohio State University Medical Center Columbus | Ohio

References

AMENITIES

Drinks

Dining

Gift

Information

Telephone

Litter disposal

Surgery

Waiting area

Diagnostic imaging

Library

Water fountain

Excercise room

Mail box

Shower room

Cashier

Locker

MISC.

Pharmacy

Physical therapy

Emergency dept.

10.2010


11

Pictograms

Ohio State University Medical Center Columbus | Ohio

References

HAZARDS

Coded in orange, Position in diamond

FIre hazard

Biohazard

Poisons

Oxidizer

Radioactivity

Generic caution

High voltage

Laser usage

Flammable

Explosive

Gloves required

Eye protection required

Respirator required

Protective coat required

Low volume required

Respirator

Eye protection

Eye wash

Body shower

Harmful to foodstuffs

Corrosive

NFPA 704 HAZ

CAUTIONS

Coded in yellow, Position in triangle

Caution footing

Magnets

REQUIREMENTS

Coded in green, Position in circle

AVAILABILITY

Coded in blue, Position in circle

UV disinfectant

10.2010


12

General Sizes and Proportions

Ohio State University Medical Center Columbus | Ohio

Freestanding and Other Large Scale Signage

Proportional Shapes Visual consistency of the display and freestanding members of the signage family is achieved using a standard building block of an 8” x 8” square. The standard unit was applied incrementally to both horizontal and vertical measurements as necessary to increase sign to a viable size. Deviations are allowed when proportional sizes are not permissible due to the manufacturing process or existing graphical standards.

8”

11X

8”

2X

2.5X

2

Level Two Name of Building

2X

2

Level Two Name of Building

X

2.5X

2

2 6X

12X

Laboratory Specialty Clinic Education Center

Admissions Outpatient Clinic Solid Tumor, Hemo Oncology

Elevators

Level 19 Level 18 Level 17 Level 16 Level 15 Level 14

Information Lobby

Emergency

Admission Outpatient Clinic

2

Pharmacy

2

5X

Pharmacy Diagnostic Imaging

Admission Office

Admission Office

Infusion Dept.

Infusion Dept.

Lobby

3X

Parking

X

X

Level Two Building Name

Emergency

Diagnostic Imaging

Restrooms

Laboratory Education Center

3X

Level Two Building Name

Level Two Name of Building

Level Two Name of Building

Level 19 Level 18 Level 17 Level 16 Level 15 Level 14

Information Lobby

3X

Rooms P808-P813

Rooms P808-P813

Rooms P808-P813

Rooms P801-P804 P815-P820

Emergency Parking Garage

Radiology Acute Assessment Admission 11X

X

Emergency

Radiology

5X

Rooms P808-P813

3X 0.5X

Radiology

0.5X

Hemo Oncology

Elevators

Legend Key

Parking

Destination A Destination B Destination C Destination D

Destination A Destination B Destination C Destination D

Destination A Destination B Destination C Destination D

Destination A Destination B Destination C Destination D

Destination A Destination B Destination C Destination D

Destination A Destination B

Destination A Destination B Destination C Destination D

Destination A Destination B Destination C Destination D

Destination A Destination B

Café Gift Shop

Elevators North and West

10.2010


13

General Sizes and Proportions

Ohio State University Medical Center Columbus | Ohio

Code Required and Wall Mounted Signs

Proportional Shapes Visual consistency of wall mounted and code required members of the signage family is achieved using a standard building block of a 1.75” x 1.75” square. The standard unit was applied incrementally to both horizontal and vertical measurements as necessary to increase sign to a viable size. Small deviations are allowed when proportional sizes are not permissible due to the manufacturing process or existing graphical standards.

1.75” 3.5 X

3.5 X

3.5 X

3X

3X

3X

3.5 X

4X

4X

5X

1.75”

Stair East West Stair C X

P1245

P1245 3X

Examination Room Descriptions Here

12300 4X

Critical Care Unit Patient’s Name Doctor’s Name (AM) Doctor’s Name (PM) Nurses’ Names

4X

In the event of emergency, this phone will provide direct contact to security and emergency personnel.

Area of Refuge

In Fire Emergency, Do Not Use Elevator. Use Exit Stairs. Evacuation Map

5X

5X

6X

5X

9X

7X

15

Re-Entry on L5-10

Emergency Phone

Down To 1ST Floor For Exit Discharge

EXIT

MEN

EXIT

EXIT

5.5” x 8.5” evacuation map

10.2010


14

Neutral Color Scheme

Ohio State University Medical Center Columbus | Ohio

Color Usage in Signage Family Overall Color Scheme

Message and Accent Colors

with the available ambient light and the ambient color of the environment, resulting in better visual integration and

are chosen for their vibrancy (ability to draw viewers’ attention), and also for their attractiveness/visual compatibility when

overall color temperature. Expect interesting dynamic visual shifts in daytime and nightime appearance.

used along side with the neutral color scheme of the signs. Name of colors are pronounceable for verbal referencing.

The base color of the sign family is the translucent, milky white, natural finish of the Chroma material. Chroma “blends”

Additional colors are to be used to reinforce the contents of the message when presented as part the signage system. Colors

Dark Grey For legibility and contrast; paint or as Chroma material color

S

E

C

Orange: In the ranges of PMS 151 to distance away from yellow

Light Grey O

N

D

For visual contrast; paint or as Chroma material color

Teal: In the ranges of PMS 312, between the hues of green and blue

Black: Process black

A R

Y

White C

For visual contrast; paint or silk screening

O

L O R

S

OSU Red Brand recognition and visual contrast; paint or as Chroma material color

Neutral Colors

Original Material color, Translucency, Neutral Off-White

Yellow: In the ranges of PMS 108 with a slight magenta content

Green: In the ranges of PMS 368

Blue: In the ranges of PMS 3005

10.2010


15

Materials

Ohio State University Medical Center Columbus | Ohio

Introduction to Materials on Freestanding Signs A

Overview of Material Selection & Specification for

B

Large & Free Standing Sign Types A

3form Chroma

®

Clear Acrylic

Optically clear acrylic without color tints or texture. Diamond polished at all exposed edges. Use matte paint on first surface only, leave edges unpainted when D

Color: White Finish: Renewable Matte

applying colors.

Bold, solid, translucent surface with the ability to saturate with C

custom colors. The translucent quality of Chroma® helps blend the ambient light and takes on complimentary appearance to its

Vinyl

Cut out vinyls adhered to first surface of frosted panels.

surroundings. Chroma® contains 40% pre-consumer recycled

Matte finish.

material and is more ecological than other resins or polycarbonates. It can be resurfaced and re-colored during maintenance therefore allowing for longer life span of signage. Exposed edges are finished

D

and blemish-free.

Retainer Frame

Other ideal attributes include:

Use to hide fasteners or other hardware from view.

Durability — solid and sturdy for a variety of horizontal or vertical applications

Frame also serves as a structural support element and

Formable — can be shaped to accommodate radius curves

D

covers at least three sides of the sign structure. Matte,

Renewable — surface can be renewed after years of use Structural — thick and stable for engineered load bearing applications Translucent — amazing clarity for unrivaled light transmission

platform for attachment of Chroma® panels. Frame

B

brushed metal finish.

B

For additional information, visit http://www.3-form.com/materials-chroma.php C B B

10.2010


16

Materials

Ohio State University Medical Center Columbus | Ohio

Introduction to Materials on Wall Mounted Signs Overview of Material Selection & Specification for

B

A

Code Required Sign Types

D

D

Backer

Frosted acrylic panel with similar look and feel of the Ecoresin®. Diamond polish/ smooth finish all exposed edges. Adhere directly to the second surface of

A

3Form Varia Ecoresin

Ecoresin®. Use 1/8” thickness for structural rigidity.

®

Style: White Out FF: Supermatte BF: Supermatte E

Frosted visually and texturally. All exposed edges to be finished with

E

consistent texture as the main surfaces. Info: http://www.3-form.com/materials-varia_ecoresin.php

B

Spacer

Frosted acrylic panel for placement of double-sided tape or adhesive when C

Clear Engraving Stock / Photopolymer

mounting on wall. Optional to use opaque panel to block visibility of mounting hardware from showing through from the front of sign. Spacer panel lifts sign off the wall and is hidden from view.

Optically clear acrylic without color tints or texture. Tactile and braille created on this layer. Adhere to first surface of Ecoresin®.

C

Clear Acrylic

Ex Deamin sc at rip ion tio R ns oo He m re

Optically clear acrylic without color tints or texture. Diamond polished at all exposed edges. Use matte paint on first surface when applying colors.

D

Paint on first surface only

Paper Insert

Conventional, full-color laser printing.

A

D

Paper stock of 90lbs. and up.

Clear sides and edges

10.2010


17

Alternate Material Sets

Ohio State University Medical Center Columbus | Ohio

Material Substitutions OSUMC Wayfinding System Material Sets

Preferred/Proposed Material Set

Three suggested material sets are acceptable options in reducing costly material usage. Alternate material sets are to mimic the appearance of Chroma with substitute proprietary or non-proprietary materials to acheive visual continuity throughout sign family.

Alternate Material Set 1

Alternate Material Set 2

Alternate Material Set 3

Freestanding Sign Types (high visibility and high traffic locations; large in mass but few in numbers)

Polycarbonate (Level indicator)

Polycarbonate

Chroma

Chroma

®

View

Polycarbonate

Polycarbonate Frosted Polycarbonate

®

View

View

View

Chroma ® or Ecoresin ® Cost of Chroma > Cost of Ecoresin

Expensive

Inexpensive 1/4” thick Ecoresin ® with Patina finish and translucency to match look of Chroma

1/2” Chroma ®

Code Required Sign Types (appear throughout building; small in mass but numerous in numbers) View

View

1/4” thick Frosted Polycarbonate

View

1/4” thick Frosted Polycarbonate

View

Clear acrylic (window for insert)

Clear acrylic

Clear acrylic

Clear acrylic

Clear photopolymer for tactile and braille

Clear photopolymer for tactile and braille

Clear photopolymer for tactile and braille

Clear photopolymer for tactile and braille

10.2010


18

Internal Illumination

Ohio State University Medical Center Columbus | Ohio

Subtle Visual Accent on Freestanding Signage Accent Illumination

Location of LED Diodes

For installation on large, freestanding signage only. A subtle light

The light source is directed vertically from bottom to top

source can be placed at the bottom of the sign causing the sign to

in a gradual fade as brightness dims toward the top of

give off an attractive “glow”. The translucency of the Chroma®

sign. LED diodes and supporting components are

material will naturally carry light through the body of the sign,

located within the metallic base of the sign which will be

therefore, low-intensity light source such as LED is acceptable.

expansion bolted to ground. Intensity of the LED to

Diffuse light source and tune color temperature of LED (using

carry through at least half of height of sign.

tinted films) to best compliment interior lighting.

2

Level Two Name of Building

Information Lobby

2

Level Two Name of Building

2

2

Level Two Name of Building

Laboratory Education Center

Other LED illuminated surfaces include map graphics

Admission Outpatient Clinic

Information Lobby

Elevators

Elevators’ names here

Laboratory Education Center

Admission Outpatient Clinic

2

Level Two Name of Building

Emergency

Emergency

Emergency

Emergency

Infusion Department

Infusion Department

Infusion Department

Infusion Department

CTU/ Pharmacy

CTU/ Pharmacy

CTU/ Pharmacy

CTU/ Pharmacy

Outpatient Clinic

Outpatient Clinic

Outpatient Clinic

Outpatient Clinic

North and West

19 19 Name 19 19

Name 19 19

Name 19 19

Name

Pictogram One

Elevators

Direction of light

Destinations

Pictogram Four

Pictogram Two

Pictogram Five

Pictogram Two

Pictogram Five

To reach Building Security: 123-584-9648 Medical Center Information: 123-584-9648 Special Assistance: 123-584-9648

Name Name

Location of LED Base Open

10.2010


19

Header and Legend Graphics

Ohio State University Medical Center Columbus | Ohio

Details and Descriptions

Double sided sign

2

.25”

2

Large Numeral Level Indicator Clear acrylic panel .25” in thickness cut into shape. Adhere to surface of sign. Silk screen front surface with PMS 421 in matte, eggshell finish. Leave sides unpainted. Diamond polish all exposed edges. Level Indicator Clear acrylic panel .25” in thickness cut into shape. Adhere to surface of sign. Silk screen surface with red* in matte, eggshell finish. Leave sides unpainted. Diamond polish all exposed edges.

Level Two The James Cancer Center

Building Name Display Confirm building name with owner prior to fabrication Clear acrylic panel .25” in thickness cut into shape. Adhere to surface of sign. Silk screen front surface with PMS 425 in matte, eggshell finish. Leave sides unpainted. Diamond polish all exposed edges.

Chroma ®

Directional Arrow Clear acrylic panel .25” in thickness cut into shape. Adhere to surface of sign. Silk screen front surface with red* in matte, eggshell finish. Leave sides unpainted. Diamond polish all exposed edges.

Admissions

Chroma ®

Outpatient Clinic

Raised acrylic surfaces

Raised acrylic surfaces

Leave sides unpainted & clear

Painted surface

Chroma ® Legend 3M vinyl to match dark gray PMS 425. Directional Arrow

Laboratory

Retainer Frame

2 dimensional vinyl letters *Obtain OSU brand PMS color in red

1

Typical Header Graphics and Legend — Front View

2

Side View

3

Isometric

H

Scale NTS

H

Scale NTS

H

Scale NTS

10.2010


20

Header Graphics Layouts and Typopgrahic Details Header Graphics — Level Indicators and Building Name Visual consistency of the display and freestanding members of the signage family is

1.75”

achieved using a standard building block of an 8” x 8” square. The standard unit was applied incrementally to both horizontal and vertical measurements as necessary to increase sign to a viable size. Small deviations are allowed when standardized sizes are not permissible due to the manufacturing process.

11.625”

2”

1.5”

G

Ground Level James Cancer Center

Ohio State University Medical Center Columbus | Ohio

Large Numeral Level Indicator Font: Whitney Book Italic Size: Approx. 1175 pts.

Level Indicator Font: Whitney Semibold Size: Approx. 100 pts. Building Name Display Font: Whitney Book Italic Size: Approx. 100 pts.

1”

1

Sample Layouts

LI

Scale 1:4

10.2010


21

Header Graphics

Ohio State University Medical Center Columbus | Ohio

Sample Layouts

G

1 2 4 5 6 9 11

Ground Level Name of Building

Ground

Level One Name of Building

Level One

Level Two Name of Building

Level Two

Level Four Name of Building

Level Five Name of Building

Level Five

Level Four

Level Six Name of Building

Level Six

Ground Eleven Name of Building

Level Nine Name of Building

Level Nine

Level Eleven

12 13 14 15 16 17 18 19 Level Twelve Name of Building

Level Twelve

1

Sample Layouts

LI

Scale 1:15

Level Thirteen Name of Building

Level Thirteen

Level Fourteen Name of Building

Level Fourteen

Level Fifteen Name of Building

Level Fifthteen

Level Sixteen Name of Building

Level Sixteen

Level Seventeen Name of Building

Level Seventeen

Level Eighteen Name of Building

Level Eighteen

Level Nineteen Name of Building

Level Nineteen

Note: Levels 3, 7, 8 are omitted from building 10.2010


22

Interior Signage

Ohio State University Medical Center Columbus | Ohio

Sign Family Overview

Note on Overhead Sign Types Adjust length of Vertical Support in

Emergency

AMTU/Apherisis

proportion to available ceiling height.

Overhead Directional

[OD]

2

2

2

2

Level Two Name of Building

Level Two Name of Building

Note on Wall Mounted Signs Mounting height is flexible and is ultimately determined by available wall space.

Emergency

Level 19 Level 18 Level 17 Level 16 Level 15 Level 14

Information Lobby

Laboratory Education Center

2

Admission Outpatient Clinic

Level Two Name of Building

Destinations Emergency

Emergency

Emergency

Emergency

Infusion Deptartment

Infusion Deptartment

Infusion Deptartment

Infusion Deptartment

CTU/ Pharmacy

CTU/ Pharmacy

CTU/ Pharmacy

CTU/ Pharmacy

Outpatient Clinic

Outpatient Clinic

Outpatient Clinic

Outpatient Clinic

19 19 Name 19 19

Name 19 19

Name 19 19

Name

Pictogram One

Pictogram Four

Pictogram Two

Pictogram Five

Pictogram Two

Pictogram Five

To reach Building Security: 123-584-9648 Medical Center Information: 123-584-9648 Special Assistance: 123-584-9648

Name Name

Elevators

Level 19 Level 18 Level 17 Level 16 Level 15 Level 14

Information Lobby

Laboratory Specialty Clinic Education Center

Admissions Outpatient Clinic

2

Level Two Name of Building

Level Two Name of Building

Level Two Name of Building

2

Level Two Building Name

Emergency

Pharmacy

Pharmacy

Diagnostic Imaging

Diagnostic Imaging

Admission Office

Admission Office

Infusion Dept.

Infusion Dept.

Lobby

Parking

Elevators

Legend Key

Parking

Destination A Destination B Destination C Destination D

Destination A Destination B Destination C Destination D

Destination A Destination B Destination C Destination D

Destination A Destination B Destination C Destination D

Destination A Destination B Destination C Destination D

Destination A Destination B

Destination A Destination B Destination C Destination D

Destination A Destination B Destination C Destination D

Destination A Destination B

CafĂŠ Gift Shop Restrooms Waiting Rooms

Solid Tumor, Hemo Oncology

Elevators

North and West

Note on Height Empty space at the lower portion can be reduced to shorten height of sign. Additional graphical adjustments may be necessary to ensure an optimal presentation.

Table Map

[TM]

Location Beacons

Small Freestanding Directional

Large Freestanding Directional

[LB]

[FS]

[FL]

Freestanding Map

[FM]

Wall Mounted Directional

Small Wall Mounted Directional

[WD]

[SD]

Scale 1:30

10.2010


23

Interior Signage

Ohio State University Medical Center Columbus | Ohio

Sign Family Overview

Perpendicular Pictogram

[PP]

West Stair C

WOMEN

EXIT EXIT

Stair East

15

P12345

P12345

P12345 Hemo Oncology Dr. Mallisu Dr. York

npo

Critical Care Unit Patient’s Name Doctor’s Name (AM) Doctor’s Name (PM) Nurses’ Names

Room Available

Re-Entry on L5-10 Down to 1 ST Floor For Exit Discharge

Restroom Sign

Tactile Exit Sign

[RR]

[TE]

Stairway Identification

[SI]

Stair Sign

Room Number

[SS]

[RN]

Room Number With Insert

[RI]

Patient Room Sign

[RP]

10.2010


24

Interior Signage

Ohio State University Medical Center Columbus | Ohio

Sign Family Overview

Overhead Pictogram Sign

Surgery — Descriptions

Intravenous Radiation

PACU — Descriptions

Restrooms Vending Machines Family Waiting Room

Peri-Op — Descriptions

Level Four

OutpatientClinic — Solid Tumor

CTU

OutpatientClinic — Hemo Oncology

Pharmacy

Restrooms Vending Machines Family Waiting Room

Infusion Department Level Two

In Fire Emergency, Do Not Use Elevator. Use Exit Stairs. Evacuation Map

Café Cafeteria Pharmacy

Pharmacy Lobby AMTU/ Apherisis

Restrooms Vending Machines Family Waiting Room

Restrooms Vending Machines Family Waiting Room

Conference Education Admissions Lobby

Corner Mounted Pictogram

Elevator Landing Sign

Floor Overview

[CP]

[EL]

[FO]

Conference Rooms

4 2

1

Level One

Restrooms Vending Machines Family Waiting Room

Ground

G

10.2010


25

Interior Signage

Ohio State University Medical Center Columbus | Ohio

Sign Family Overview

Dimensional Letters

Emergency Unit Level 8

Emergency Instructions • Rinse the wound thoroughly with water to clean out dirt and debris. • Then wash the wound with a mild soap and rinse thoroughly. (For minor wounds, it isn't necessary to use an antiseptic solution to prevent infection, and some can cause allergic skin reactions.) • Cover the wound with a sterile adhesive bandage or sterile gauze and adhesive tape. • Examine the wound daily. If the bandage gets wet, remove it and apply a new one. After the wound forms a scab, a bandage is no longer necessary. • Call your child's doctor if the wound is red, swollen, tender, warm, or draining pus.

Evacuation Plan

You Are Here

Restricted Zone

High Voltage Zone ADDITIONAL INFORMATION

PULL

7

4

Radiation

Spontaneously Combustible

CONTENTS & ACTIVITY

PULL

First Aid

AED

Gloves Required

Eye Protection Required

Eye Wash Available

Chemical Shower Available

Authorized Personnel Only Do Not Enter

Movable Stanchion

[MS]

Fire Safety Station

Fire Safety Station

Life Safety Station

Door Mounted Safety Information

[DS]

10.2010


Interior Sign Family Descriptions and Design of Individual Sign Types


27

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Large Freestanding Directional [FL]

Fastener

Top panel

20”

4.5”

2

Numeral level indicator Level indicator

Level Two Name of Building

See page on Header and Legend Graphics

La bo S p r a to ec r E d ialt y y uc a t i Cl i n on ic Ce n te r Ad m O u is si tp a o n So lid ti e Tu m Ele or, Hemo nt C va Oncolo lin tor gy ic s

Information Lobby

Laboratory Specialty Clinic Education Center

78”

96” Admissions Outpatient Clinic Solid Tumor, Hemo Oncology

Elevators

Expansion bolts secure to ground

12” 19” open

6.5”

Inf o Lo r m at bb i y on

.5”

Building name display

Stainless steel retainer frame

Chroma ®

Exposed edges of Chroma ® panel; sand and smooth to match finish on face Elevated stainless steel base; non-glare with satin finish

1”

1

Large Freestanding Directional

2

Side View

3

Isometric

FL

Scale 1:25

FL

Scale 1:25

FL

Scale NTS

10.2010


28

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Freestanding Directional [FS] Fastener

Top panel

16”

Numeral level indicator

4.5”

2

Level indicator

See page on Header and Legend Graphics

Level Two Name of Building

Stainless steel retainer frame

Information Lobby

78”

Building name display

Laboratory Education Center 96”

Chroma ®

Admission Outpatient Clinic Elevators

Exposed edges of Chroma ® panel; sand and smooth to match finish on face

North and West

Expansion bolts secure to ground

12” 19” 6.5”

Elevated stainless steel base; non-glare with satin finish

.5” 1”

1

Freestanding Directional

2

Side View

3

Isometric

FS

Scale 1:25

FS

Scale 1:25

FS

Scale NTS

10.2010


29

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Freestanding Map [FM] 2.5”

20”

15”

2

6.5” 20”

2

.75”

2.5”

.25”

1.75”

Note: This signtype is intended to be a single-sided sign. The thickness of width can be adjusted to accomodate for a double sided modification.

See page on Header and Legend Graphics

Level Two Name of Building

Level Two Name of Building

5”

Level 19 Level 18 Level 17 Level 16 Level 15 Level 14 Level 19 Level 18 Level 17 Level 16 Level 15 Level 14

Level 19 Level 18 Level 17 Level 16 Level 15 Level 14 Level 19 Level 18 Level 17 Level 16 Level 15 Level 14

View

View

Retainer frame 78”

Opening for map; duratrans printed graphics and backlit

Legend Key Destination A Destination B Destination C Destination D

Destination A Destination B Destination C Destination D

Destination A Destination B Destination C Destination D

Destination A Destination B Destination C Destination D

Destination A Destination B Destination C Destination D

Destination A Destination B

Destination A Destination B Destination C Destination D

Destination A Destination B Destination C Destination D

96”

Destination A Destination B

58.75”

Legend Key

12”

Destination A Destination B Destination C Destination D

Destination A Destination B Destination C Destination D

Destination A Destination B Destination C Destination D

Destination A Destination B Destination C Destination D

Destination A Destination B Destination C Destination D

Destination A Destination B

Destination A Destination B Destination C Destination D

Destination A Destination B Destination C Destination D

Destination A Destination B

Chroma ®

19”

Chroma ®

6.5” .5” 1”

1 FM

Freestanding Map Scale 1:25

2

Side View

3

FM

Scale 1:25

FM

Front Details Scale 1:15

4 FM

Side Details Scale 1:8

10.2010


30

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Freestanding Map [FM] Fastener Detachable panel for access to interior electronic components

Top panel

Map on duratrans output

Numeral level indicator Level indicator

Lev el Lev 19 el Lev 18 el Lev 17 el Lev 16 el Lev 15 el 14 Lev el Lev 19 el Lev 18 el Lev 17 el Lev 16 el Lev 15 el 14

LED light source Lev el Lev 19 el Lev 18 el Lev 17 el Lev 16 el Lev 15 el 14 Lev el Lev 19 el Lev 18 el Lev 17 el Lev 16 el Lev 15 el 14

Le

ge

Des Destinat Destination A Destination B tin ion atio C nD Des Destinat Destination A Destination B tin ion atio C nD Des Destinat Destination A Destination B tin ion atio C nD Des Destinat Destination A Destination B tin ion atio C nD

nd

Ke

Des Destinat Destination A Destination B tin ion atio C nD Des Destinat Destination A Destination B tin ion atio C nD Des Destinat Destination A Destination B tin ion atio C nD Des Destinat Destination A Destination B tin ion atio C nD

Le

ge

Des Destinat Destination A Destination B tin ion atio C nD

Diffuser panel

Des Destinat Destination A Destination B tin ion atio C nD Des Destinat Destination A Destination B tin ion atio C nD

Inset

y Des Destinat Destination A Destination B tin ion atio C nD Des Destinat tin ion atio A nB

Des Destinat Destination A Destination B tin ion atio C nD

Des Destinat tin ion atio A nB

Des Destinat tin ion atio A nB

nd

Ke

Des Destinat Destination A Destination B tin ion atio C nD Des Destinat Destination A Destination B tin ion atio C nD Des Destinat Destination A Destination B tin ion atio C nD Des Destinat Destination A Destination B tin ion atio C nD

Building name display

y Des Destinat Destination A Destination B tin ion atio C nD Des Destinat tin ion atio A nB

Des Destinat tin ion atio A nB

Stainless steel retainer frame

Des Destinat tin ion atio A nB

Chroma ÂŽ

Exposed edges of Chroma ÂŽ panel; sand and smooth to match finish on face Expansion bolts secure to ground

Protective clear glass or acrylic panel

1

Isometric

2

Isometric

FM

Scale 1:25

FM

Scale 1:15

Elevated stainless steel base; non-glare with satin finish

10.2010


31

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Location Beacon [LB] Fastener

Top plate

8”

Numeral level indicator

4.5”

2

Level indicator

Building name display

Level Two

Name of Building

Stainless steel retainer frame

78” 96”

Chroma ®

Exposed edges of Chroma ® panel; sand and smooth to match finish on face

Expansion bolts secure to ground

12” 19” 6.5”

Elevated stainless steel base; non-glare with satin finish

.5” 1”

1

Location Beacon

2

Side View

3

Isometric

LB

Scale 1:25

LB

Scale 1:25

LB

Scale NTS

10.2010


32

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Table Map [TM]

Duratrans map graphics on elevated platform; backlit with neutral temperature LED light Side column space for level indicator and supporting graphics

60”

30”

2

Level Two Name of Building

Elevated stainless steel base; non-glare with satin finish

Destinations Emergency

Emergency

Emergency

Emergency

Infusion Deptartment

Infusion Deptartment

Infusion Deptartment

Infusion Deptartment

CTU/ Pharmacy

CTU/ Pharmacy

CTU/ Pharmacy

CTU/ Pharmacy

Outpatient Clinic

Outpatient Clinic

Outpatient Clinic

Outpatient Clinic

19 19 Name 19 19

Name 19 19

Name 19 19

Name

Pictogram One

Pictogram Four

Pictogram Two

Pictogram Five

Pictogram Two

Pictogram Five

Name

To reach Building Security: 123-584-9648

Name

Medical Center Information: 123-584-9648 Special Assistance: 123-584-9648

55” 5”

Expansion bolts secure to ground

Stainless steel Retainer Tray; non-glare with satin finish

Chroma®

12”

Open

Open

(See separate RTKL technology package for monitor based maps)

6.5” .5” 1”

6.5”

1

Table Map

2

TM

Scale 1:25

TM

Right Side View Scale 1:25

3

Isometric

TM

Scale NTS

10.2010


33

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Table Map [TM] Main Map Graphics Backlit with LED

Side Margin for support information to adjacent map graphics

2

Backlit map Dimensional “You Are Here” indicator

Chroma ® 1/2” inset

Level number and other building information

Level Two Name of Building

Clear acrylic header with painted surfaces. See section on header graphics

Destinations Emergency

Emergency

Emergency

Emergency

Infusion Deptartment

Infusion Deptartment

Infusion Deptartment

Infusion Deptartment

CTU/ Pharmacy

CTU/ Pharmacy

CTU/ Pharmacy

CTU/ Pharmacy

Outpatient Clinic

Outpatient Clinic

Outpatient Clinic

Outpatient Clinic

Chroma ® 19 19 Name 19 19

Name 19 19

Name 19 19

Name

Pictogram One

Pictogram Four

Pictogram Two

Pictogram Five

Pictogram Two

Pictogram Five

To reach Building Security: 123-584-9648 Medical Center Information: 123-584-9648 Special Assistance: 123-584-9648

1/2” inset

Name Name

Overview Building Map Indications of all levels in building and the location of viewer within building

Open

Legend, Pictograms, and Notes

1 TM

Sample Map Layout Scale 1:10

2 TM

Prespective View Scale NTS

10.2010


34

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Table Map [TM]

60”

2

44.625”

Top Protective glass

15”

24”

Level Two Name of Building

35.75”

Header graphics

Destinations Emergency

Emergency

Emergency

Emergency

Infusion Deptartment

Infusion Deptartment

Infusion Deptartment

Infusion Deptartment

CTU/ Pharmacy

CTU/ Pharmacy

CTU/ Pharmacy

CTU/ Pharmacy

Outpatient Clinic

Outpatient Clinic

Outpatient Clinic

Outpatient Clinic

19 19 Name 19 19 19

Name 19 19

Name

Pictogram One

Pictogram Four

Pictogram Two

Pictogram Five

Pictogram Two

Pictogram Five

To reach Building Security: 123-584-9648 Medical Center Information: 123-584-9648 Special Assistance: 123-584-9648

Duratrans map graphics

19

Name

11.5”

Name Name

Diffuser panel Uniform LED light source* floods entire surface.

59.75”

Edge of retainer tray; 1/8 thick stainless steel

1 TM

Measurements Scale 1:10

*CeeLite LEC ultra thin, flexible illuminated panels recommended

2 TM

Mapping Display Composite Scale NTS

10.2010


35

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Wall Mounted Directional [WD] Retainer Tray. Aluminum construction for structural rigidty; in non-glare, satin finish.

.25” 24”

16”

2

Level Two Name of Building 4” Full Panel

Emergency

Header — Chroma ® P: Chroma White Out FF: Renewable Matte

1”

Reverse silk screen printed surface on Chroma ®. Background color in OSU red* in matte eggshell finish. Silk screen typography and arrow symbols; see alternate application options on pg. 38

1/16” gap

View

57.875”

Lobby 2” Half Panel

Legend Panel — Chroma ® P: Chroma White Out FF: Renewable Matte

Elevators Parking Café Gift Shop Restrooms Waiting Rooms

Individual Legend Panels are detachable with magnetic attachments

Re s

Ad

mis

sio

nO

ffic

1

Wall Mounted Directional Scale 1:15

2

Isometric

WD

Scale NTS

rge

rm

gno sio

tro

e

ncy

ac y

stic

nD

Lo b o m s by Ele vat Par or s kin Ca g fé G if t Sh op

Placeholder panels

WD

Pha

I nf u

Admission Office Infusion Dept.

Em e D ia

Pharmacy Diagnostic Imaging

Header graphics. Adjust graphics to fit within alloted area. See section on Header Graphics.

Ima

e pt

.25” protruded and exposed surfaces of Legend Panels

g in

g

. Reverse silk screen printed surface on Chroma®. Background color in PMS 425 in matte eggshell finish.

*Obtain OSU brand PMS color

10.2010


36

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Wall Mounted Directional [WD]

Retainer Tray Inset groove with matching shape magnet attachment; act as alignment guides

Z Clips Full panel*

2

Level Two Name of Building

Emergency

Wall Magnet

View

Half panel*

Open

Level Fifteen Name of Building

Peri-Op Rm

Admission Office

Pharmacy

PACU

Reserch Labs 1-5

Diagnostic Imaging

Diagnostic Imaging

Rm 15100-15250

Admission Office

Surgery Rm

Rm 15251-15300

Infusion Dept.

Infusion Dept.

Research Labs 6-10

Lobby

Admission Office

Acute Care Unit

Parking

Peri-Pro Rm

Rm 15301-15350

CafĂŠ

CafĂŠ

Elevators

Enlarged View

4 15

Level Four Name of Building

Gift Shop

Scale 1:3

Restrooms Waiting Rooms

Blank placeholders

Blank placeholders

*Use Chroma White Out with renewable matte surface to block visibility of magnets / interanal hardware

1 WD

Wall Mounted Directional Scale 1:15

2 WD

Sample Layouts Scale 1:15

10.2010


37

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Small Wall Mounted Directional [SW]

24”

16”

.25”

2

1” Retainer Tray. Aluminum construction for structural rigidty; in non-glare, satin finish.

Header — Chroma ® P: Chroma White Out FF: Renewable Matte

Reverse silk screen printed surface on Chroma ®. Background color in OSU red* in matte eggshell finish.

Level Two Building Name 4”

Emergency Pharmacy

Em e

Silk screen typography and arrow symbols View

Pha

40”

D ia Ad

Diagnostic Imaging Legend Panel — Chroma P: Chroma White Out FF: Renewable Matte

Admission Office Infusion Dept.

Individual Legend Panels are detachable with magnetic attachments

Parking

Ad

mis

nO

ffic

stic

sio

sio

k in

ncy

ac y

gno

mis

Pa r sio

rge

rm

I nf u

®

Header graphics. Adjust graphics to fit within alloted area. See section on Header Graphics.

nO

nD

g

Ima

g in

ffic

e pt

.25” protruded and exposed surfaces of Legend Panels

g

e

.

e

*Obtain OSU brand PMS color in red

1 SW

Small Wall Mounted Directional Scale 1:10

2

Isometric

SW

Scale NTS

10.2010


38

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Details for WD and SW Ground color silk screen printed Symbols and typography left unprinted

Retainer Tray

Silk screened printed

Alternate Legend Application Option A Apply vinyl letters on top of pre-silk screened fields. Silk screened color fields are to be left unchanged and to be reused. Remove and reapply new vinly without damaging silk screened color surface during updates. Vinyl graphic

Vinyl letters

Silk screened printed 1/16� seam between Legend Panels Silk screened printed Protruded edge of Legend Panel

Emergency Pharmacy Parking Vinyl letters

Legend Panel

Indentation for matching magnetic plates on back of Legend Panels Ground color silk screen printed

1/16� seam between Legend Panels Indentation for matching magnetic plates

Silk screen printed background color field

Alternate Legend Application Option B Apply reverse cut vinyl graphic (letters and symbols) on first surface of an individual Legend Panel. Leave sides and edges clear of vinyl. Remove entire vinly graphic during updates.

Reverse cut vinyl graphic

Symbols and typography left unprinted

Open

1 TYP

Legend Panel

Details of Sign Type WD and SW Scale NTS

10.2010


39

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Wall Mounted Map [WM]

.5”

2

24”

16”

.75”

Retainer Frame

Header — Chroma ® P: Chroma White O ut FF: Renewable Matte

Header graphics. Adjust graphics to fit within alloted area. See section on Header Graphics. .25” protruded and exposed surfaces of Legend Panels Routed to receive clear acrylic Protective Panel

Level Two Building Name

View

Retainer Frame Aluminum construction for structural rigidty; in non-glare, satin finish.

Routed edge

High quality map output insert

40”

Chroma ® 23” 19 19 19 19 19 19 19 19

Destinations

De Em

Emergency

Emergency

Emergency

Infusion Deptartment

Infusion Deptartment

Infusion Deptartment

CTU/ Pharmacy

CTU/ Pharmacy

CTU/ Pharmacy

Outpatient Clinic

Outpatient Clinic

Outpatient Clinic

Pictogram One

Pictogram Four

Pictogram Two

Pictogram Five

Pictogram Two

Pictogram Five

Clear acrylic Protective Panel with diamond polished edges

1” Set screw

1 WM

Small Wall Mounted Directional Scale 1:10

stin

atio

erge Infu ncy sio CT n Dep U/ ta Ou Pharm rtmen tpat t ien acy tC linic

ns

Em

erge Infu ncy sio CT n Dep U/ ta Ou Pharm rtmen tpat t ien acy tC linic

19

Em erge Infu ncy sio CT n Dep U/ ta Ou Pharm rtmen tpat t ien acy tC linic

19 19 19 19 19 19 19

Pict ogra Pict m One ogra Pict m Tw o ogra m Tw o

Pict ogra Pict m Four ogra Pict m Fiv e ogra m Fiv e

Routed edge

2

Isometric

WM

Scale NTS

10.2010


40

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Floor Overview [FO]

Su

rg e PA r y — CU De — Pe D scr riO p e s c i p ti o rip n — D e ti o n s sc s rip ti o Ou ns tp O u a ti e nt tp Cl ini I n f a ti e c n us i o n t Cl i n — S o li ic De pa — H d Tu r tm m e en mo O or t nc olo g

Other levels are summarized

Surgery — Descriptions

Intravenous Radiation

PACU — Descriptions

Restrooms Vending Machines Family Waiting Room

Peri-Op — Descriptions

Level Four

OutpatientClinic — Solid Tumor

CTU

OutpatientClinic — Hemo Oncology

Pharmacy

Infusion Department

Restrooms Vending Machines Family Waiting Room

Level Two

Café Cafeteria Pharmacy

Diagnostic Imaging Adjacent Building

Restrooms Vending Machines Family Waiting Room

Conference Education

Pharmacy Lobby AMTU/ Apherisis Restrooms Vending Machines Family Waiting Room

Conference Rooms

Admissions Lobby

4 2

Ca fé Ca fe P h te r i a ar ma Re s cy Ve troo m n F din s am

1

g ily Ma W ch ait ine ing s Ro o

Vending Machines Family Waiting Room

Ground

CT

ve

no

us

Ra

dia

ti o

n

U

ar

m

ma

cy

Re st Ve room nd s Fa i n g Ma mi ly W chin ait e ing s Ro o Re st Ve room nd s Fa i n g Ma mi ly W chin ait e ing s Ro o

on

Co

G

ra

Di ag Ad n o s j a c ti c en Im t B ag u il i n g din g

Level One

Restrooms

y

Ph

Co

nf Ad e re n ce m Lo issio Edu bb ca ns ti y

Int

Current level presented on Chroma ® panel mounted on wall

nfe

re

nc

eR

oo

ms

AM

Le

ve

Le

ve

Floor Overview Wayfinding at Elevator Landing

2

Isometric

FO

Scale NTS

FO

Scale NTS

ou

r

lT wo

4 2

Fa e n d R e mil in st y W g M roo ait ach ms ing ine Ro s om

m

Gr

1

lF

m

Ph ar ma TU c / A Lo b y p h by er isi s V

Re st Ve room nd s Fa i n g Ma mi ly W chin ait e ing s Ro o

Summary of current level uses lists of legends and pictograms

m

ou

nd

G

Dimensional level indicator (for current level only)

10.2010


41

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Floor Overview [FO]

1”

Surgery — Descriptions

Intravenous Radiation

PACU — Descriptions Peri-Op — Descriptions

Restrooms Vending Machines Family Waiting Room

Level Four

OutpatientClinic — Solid Tumor

CTU

OutpatientClinic — Hemo Oncology

Pharmacy

Restrooms Vending Machines Family Waiting Room

Infusion Department

Level Two

10”

Café Cafeteria Pharmacy

Diagnostic Imaging Adjacent Building

Pharmacy Lobby AMTU/ Apherisis

Restrooms Vending Machines Family Waiting Room

Conference Education

Restrooms Vending Machines Family Waiting Room

Conference Rooms

Admissions

Restrooms Vending Machines

Ground

TBD (60” est.)

1

Level One

Family Waiting Room

Lobby

4 2

G

.125”

Vinyl typography and graphics apply directly on wall

Display Panel — Chroma ® P: Chroma White Out FF: Renewable Matte

View

TBD (35” est.)

10”

Vinyl typography and graphics Z Clips; Display Panels are detachable

Retainer Frame Aluminum construction in non-glare, satin finish

1

Floor Overview Wayfinding at Elevator Landing

2

Side View

FO

Scale 1:10

FO

Scale 1:3

.5”

10.2010


42

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Podium Elevator Landings — Public Information

Formal sign product or digitally printed wallpaper

Wall mounted evacuation map offers wayfinding overview

Reinforcing indicators visible from inside cab are additional options End wall exiting elevator landing is key to orientation and wayfinding

Surgery — Descriptions

Intravenous Radiation

PACU — Descriptions

Restrooms Vending Machines Family Waiting Room

Peri-Op — Descriptions

Level Four

OutpatientClinic — Solid Tumor

CTU

OutpatientClinic — Hemo Oncology

Pharmacy

Restrooms Vending Machines Family Waiting Room

Infusion Department Level Two

Café Cafeteria Pharmacy

Pharmacy Lobby AMTU/ Apherisis

Restrooms Vending Machines Family Waiting Room

Restrooms Vending Machines Family Waiting Room

Conference Education Admissions Lobby

1 TYP

Conference Rooms

4 2

1

Summary of other levels

Current level in summary

Level One

Restrooms Vending Machines Family Waiting Room

Ground

G

Elevator Landing Scale NTS

10.2010


43

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Double Door Identification Sign [DD]

Panel at the Left Side of Door

Panel at the Right Side of Door

This panel is reserved for restrictions,cautions, and other mandatory information. Color usage consistent with visual coding system for messaging.

All directional and other wayfinding information on this panel presented with arrow(s) and legends.

High quality insert Set screw; inconspicuously installed at top and bottom

.5” Set screw

Routed edge

Chroma ® P: Chroma White Out FF: Renewable Matte Routed to receive clear acrylic panel

12” .5”

Header or pictogram panel

Critical Care Rooms

12”

Nurses’ Station A

Pro Equper Reqipme Pri uir nt or to E ed R

Main Equipment Room Examination Rooms Surgery Rooms

Description or destination panel (detachable)

Proper Equipment Required Prior to Entry

Cri tica Nu l Car r se eR Ma s’ Sta oom s in E tio Exa quip n A me mi Su natio nt R rge n R o om Ro ry Ro oom om om s sP 09 s 115 -P 09 130

Rooms P09115 - P09130

View

adi ntr o y Do active No E N m t E n t q uip m e en re r d e l r u m h w i th o t . ec ut ic vol tus, u tenet prem u pt t a u u i atib t re r a sa ssion . i p us ma ciend iente io r e i s s al ia s

TBD*

Radioactive Equipment. Do Not Enter without premission. Nm rerum hic tenetur a sapiente delectus, ut aut reiciendisperferendis doloribus asperiores repellat

1”

Set screw

Chroma ® routed to receive clear acrylic panel

*Total length of sign to match length of adjacent window

1

Double Door Identification

2

Isometric

DD

Scale 1:10

DD

Scale NTS

Back Panel; 1/8” frosted acrylic panel Set screw

Clear acrylic panel with diamond polished edges Routed edge

10.2010


44

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Double Door Identification Sign [DD]

Critical Care Rooms

Main Equipment Room

Nurses’ Station A

Examination Rooms

Main Equipment Room

Surgery Rooms

Examination Rooms

Biohazard Materials Ahead

Rooms P09115 - P09130

Restricted Zone Beyond This Point

Critical Care Rooms

Entry Restricted

Nurses’ Station A

Radioactive Equipment. Do Not Enter without premission. Nm rerum hic tenetur a sapiente delectus, ut aut reiciendis voluptatibus

Examination Rooms

Do Not Enter

Main Equipment Room

Radioactive Equipment. Do Not Enter without premission. Nm rerum hic tenetur a sapiente delectus, ut aut reiciendis voluptatibus maiores alias.

Sign mounted on both sides of door at eye level

Critical Care Rooms Nurses’ Station D Rooms P09115 - P09130

Critical Care Rooms Nurses’ Station A Main Equipment Room Examination Rooms

1

Sample Layout

2

Sample Layout

DD

Scale NTS

DD

Scale NTS

Hospital Staff Only

Prior to Entry

Critical Care Rooms Nurses’ Station A Main Equipment Room Examination Rooms

Radioactive Equipment. Do Not Enter without premission. Nm rerum hic tenetur a sapiente delectus, ut aut reiciendis voluptatibus maiores alias

Critical Care Rooms

Critical Care Rooms

Nurses’ Station A

Nurses’ Station D

Main Equipment Room

Examination Rooms

Examination Rooms

Surgery Rooms Rooms P04115 - P04130

Surgery Rooms

No High Entry Without Powered Badge Magnets

Proper Equipment Required

Surgical Attire Required

Rooms P09115 - P09130

Hospital Only CautionStaff to Visitors

Prior to Entry

Do Enter NmNot rerum hic without tenetur apremission. sapiente Nm rerumuthic tenetur a sapiente delectus, aut reiciendis. Nm delectus, aut reiciendis rerum hicut tenetur a sapiente voluptatibus maiores alias. delectus, ut aut reiciendis.

Radioactive Equipment. Do Not Enter without premission. Nm rerum hic tenetur a sapiente delectus, ut aut reiciendis voluptatibus maiores alias.

with Pacemakers Radioactive Equipment.

Critical Care Rooms Examination Rooms

3

Sample Layout

4

Sample Layout

5

Typical Elevation

DD

Scale NTS

DD

Scale NTS

DD

Scale 1:20

10.2010


45

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

“Hospital Staff Only” Access Identification

Hospital Staff Only

Overhead in public circulation

Icon as part of the double door identification with infomation or instructions

P04181 Hospital Staff Only

Stand alone door mount at larger scale than double door identification signs

Hospital Staff Only

No Entry Without Badge

Scan badge at check-in counter at nurses’ station

Hospital Staff Only

Hospital Staff Only

Radioactive Equipment. Do Not Enter without premission. Nm rerum hic tenetur a sapiente delectus, ut aut reiciendis voluptatibus maiores alias.

Hospital Staff Only

Adjacent to door as sign module

Hospital Staff Only

Icon and blue field are part of the graphics on insert

Individual room signs can be coded for “Hospital

Hospital Staff Only Mark

Staff Only” using the “H” mark and its easily

Familiar “H” mark in hospital blue field plays role in coding

identifiable blue field as part of visual elements of

accessibility information. Use for restriction and filtering of

the room sign.

content and access.

1

Room Sign Sample Layout

2

Typical Elevation

HS

Scale NTS

HS

Scale 1:20

10.2010


46

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Overhead Directional [OD]

TBD

EMERGENCY

AMTU/Apherisis 1”

88”

8”

1”

3”

1”

.125”

Retainer Frame attached to Vertical Support Tube

EMERGENCY

8”

.125” Retainer Frame

1 OD

Overhead Directional Scale 1:20

Vertical Support

Vertical Support

Portruded edge in Chroma ®

Portruded edge in Chroma ®

.5”

Enlarged View Scale 1:4

2

Side View

OD

Scale 1:20

2”

.5”

Enlarged View Scale 1:4

10.2010


47

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Overhead Directional [OD]

Retainer Frame

Vertical Support. Aluminum construction for structural rigidty; in non-glare, satin finish.

Inset for Legend Panel

Retainer Frame. Aluminum construction for structural rigidty; in non-glare, satin finish.

Ra dio log

Optional to apply an additional layer of eggshell white opaque paint to the second surface of Legend Panels to reduce translucency of double sided signs

y

Ra dio log

3M vinyl for typography and symbols

EM Legend Panel — Chroma ® P: Chroma White O ut FF: Renewable Matte

ER GE NC

y

Vertical Support

Y

EM

Legend Panel inset into Retainer Frame

Open

1

Isometric

OD

Scale NTS

ER GE NC

Y

10.2010


48

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Large Overhead Directional [LO]

TBD

EMERGENCY Diagnostic Imaging Elevators

AMTU/Apherisis Pharmacy Lobby 1”

88”

16”

1”

3”

Vertical Support

Vertical Support .125”

Portruded edge of Chroma ® Legend Panel

.5”

2”

.5”

Portruded edge of Chroma ® Legend Panel

1” Retainer Frame

1

Large Overhead Directional

LO

Scale 1:20

Double sided presentation

10.2010


49

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Large Overhead Directional [LO]

Retainer Frame Inset for Legend Panel Vertical Support. Aluminum construction for structural rigidty; in non-glare, satin finish.

Optional to apply an additional layer of eggshell white opaque paint to the second surface of Legend Panels to reduce translucency of double sided signs

Retainer Frame. Aluminum construction for structural rigidty; in non-glare, satin finish.

3M vinyl for typography and symbols

Vertical Support

Legend Panel — Chroma ® P: Chroma White Out FF: Renewable Matte

1

Isometric

LO

Scale 1:NTS

Legend Panel inset into Retainer Frame

Open

10.2010


50

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Perpendicular Announcer [PA]

Open

Vinyl for typography and symbols

1.5” 3”

24”

.25”

.25”

.125”

Outpatient Registration

4”

Portruded edge of Chroma ®

Portruded edge of Chroma ®

.125” .125”

.125”

Fasteners attached to wall; flush to frame

.125”

Aluminum Retainer Frame

Legend Panel — Chroma ® P: Chroma White Out FF: Renewable Matte

Aluminum Retainer Frame

1

Perpendicular Announcer

2

Side View

PA

Scale 1:5

PA

Scale 1:5

10.2010


51

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Perpendicular Announcer [PA]

Retainer Frame Open Fasteners; install flush to frame

Optional to apply an additional layer of eggshell white opaque paint to the second surface of Legend Panels to reduce translucency of double sided signs Retainer Frame. Aluminum construction for structural rigidty; in non-glare, satin finish.

Ou tpa tie nt Re gis tra tio n

Legend Panel — Chroma ® P: Chroma White Out FF: Renewable Matte

Ou tpa tie nt Re gis tra tio n Legend Panel inset into Retainer Frame

1

Isometric

PA

Scale NTS

10.2010


52

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Perpendicular Pictogram [PP]

1.5”

Pictogram — Clear acrylic panel. Silk screen front surface with matte paint. Leave sides unpainted. Diamond polish all exposed edges.

8”

.125” Portruded edge of Chroma ®

Raised picotogram 8”

Raised picotogram

Portruded edge of Chroma ® .125”

.125”

.125”

Aluminum Retainer Frame

1

Perpendicular Pictogram

2

Side View

PP

Scale 1:3

PP

Scale 1:3

10.2010


53

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Perpendicular Pictogram [PP]

Fasteners; install flush to frame

10ft. Ceiling

9ft. Ceiling Retainer Frame. Aluminum construction for structural rigidty; in non-glare, satin finish.

90”

Raised pictogram

Pictogram Panel — Chroma ® P: Chroma White Out FF: Renewable Matte

1

Perpendicular Pictogram

2

Typical Installation Height

PP

Scale 1:3

PP

Scale 1:25

10.2010


54

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Movable Stanchion [MS]

Clear acrylic slot for paper insert: 8.5” x 11”

Chroma ®

Stainless steel

13” 13”

Stainless steel ”

5 .2

16

Authorized Personnel Only Do Not Enter

.25”

Chroma ®

1.5” 21.5”

Exposed edges of Chroma ® panel; sand and smooth to match finish on face

45” 39”

Use additional counter balance weight if necessary (enclosed within base)

12”

.5” Stainless steel base; non-glare with satin finish

open

6.5”

.5” 1”

1 MS

Movable Stanchion Scale 1:20

2 MS

Right Side View Scale 1:20

3

Isometric

MS

Scale NTS

10.2010


55

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Systematic Presentation of Pictograms Pictogram System

The retangular facade of the OSU logo graphic leads to the presentation of facility pictograms in square frames. See sample pictogram set below.

Usage of international and universal symbols presented in a visually-consistent, systematic way. The pictograms are individually framed by a 6� x 6� square fabricated with familiar materials as used on the larger freestanding signs. Supplementary legends are assigned to a designated zone either at top or bottom of square.

Level

Level

Level

Level

15 G T R

Pictogram Zone

Back

Public

9

Level

Lower Legend Zone Layout allows for legend to accompany pictogram fallling within a consistent zone

Public

Patients

Automated

Freight

Men

Women

Restroom

Family

Stairs

Alarm

Exit

Upper Legend Zone Layout allows for legend to accompany pictogram fallling within a consistent zone

Accessible

STOP

Restricted

No Access

Warning

Prohibited

Personnel

Biohazard

Some pictograms can be used with colors /color field to draw attention to sign

10.2010


56

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Organizing Elements on Horizontal Rule

Labels Significant Donations/ Donor Recognition

Significant Decision Points

Visually separate name and horizontal rule using two distinctive metallic tones/finishes.

Pictogram square plaques can be used along with dimensional legend sharing

The donor’s significance can be further emphasis by adjusting scale of the names.

the same horizontal rule. Chroma ÂŽ blocks with gray silk screen graphics

Metal tone A

Metal tone B

1501 to 1549 Metallic rule

Significant Department Destination

Significant Decision Points

Dimensional department name painted in white situated on a metallic rule. Subtext as

Pictograms, legends, and horizontal rule suspended from ceiling as one unit.

White paint letters

part of name can be included by adding an extra line below. 3M vinyl typography and graphics White paint letters

Name

Subtext

Outpatient Clinic Hemo Oncology

Rooms

1501-1549 Retainer Frame

Metallic rule

Seams create visual separation

10.2010


57

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Organizing Elements on Horizontal Rule

Precedent images of dimensional letters on horizontal rule

10.2010


58

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Flexible Combinations Using Simple Shapes

Rooms

3D letters on metal rule

1501-1549

Dorthy Citizen Wing

Pictograms as flag signs lead and identify; vertical orientation

Square plaques are larger in size when at the point of destination

Hazard and warning add on left to right atop mounting bar Icon squares lead at corners

1501 to 1549

04252 to

Restricted Zone

Radiation III Contents & Activity

Eye Protection Required

Eye Wash Available

04352

3D letters on metal rule with icon square(s) atop

1 TYP

Typical Elevation Scale 1:25

10.2010


59

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Corner Mounted Directional [CD] Align text and graphics to corner break

.625”

12”

Chroma

1”

3/8” Ecoresin Legend Panel with routed top & bottom edges

09

Rooms 09150-09180

Rooms 09150-09180

Vinyl typography and symbols

40”

30 R Cl 0 - 0oom a 21 ssro93 1 s 1-2 o 0 20 ms

va 09 t 3 1 Ro o r s 1- 0 om 93 s 09 32 Ro 20 1- 0 om 93 s 30

Elevators Rooms 09181-09200 Rooms 09201-09230

1”

Elevators Rooms 09181-09200 Rooms 09201-09230

1

21

Ele

45˚ matching break on two panels creating a 90˚ break

View

0 s 918 om - 0 s Ro 15 0 oom 9 r s 0 as 0 Cl -22

rs to va 00 E l e m s 92 o -0 Ro 18 1 30 0 9 m s 0 92 o Ro 20 1 9 0

90° Break

.25” frosted acrylic back panel

Chroma

1” Set screw

1

Corner Mounted Directional

2

Side View

3

Plan View

4

Typical Elevation

5

Isometric

CD

Scale 1:10

CD

Scale 1:10

CD

Scale 1:10

CD

Scale 1:25

CD

Scale NTS

10.2010


60

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Corner Mounted Pictogram [CP]

5.75”

5.75”

5.75”

.5”

.25”

5.75”

View

5.75”

Emergency .25” Three-Up Arrangement .625” Set screw per pictogram

Set screw

Retainer Frame. Aluminum construction for structural rigidty; in non-glare, satin finish.

View

Pictogram Panel* — Chroma ® P: Chroma White Out FF: Renewable Matte Two-Up Arrangement

Silk Screened typography and symbols

*Optional to use Ecoresin for lowering material cost

1

Corner Mounted Pictogram

2

Side View

CP

Scale 1:4

CP

Scale 1:4

10.2010


61

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Corner Mounted Pictogram [CP]

Emergency

1

Typical Elevation

2

Isometric

CP

Scale 1:25

CP

Scale NTS

10.2010


62

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Destination Vocabulary Per Department

Diagnostic Imaging Reception and Patient Sign In For after hours assistance and information call 123-456-7890 or visit www.departmentname.com

Slot fixture backlights imagery of department’s competency

Diagnostic Imaging

Three dimensional legend on horizontal rule indicating department name

Department name on pylon

Front Desk & Patient Sign In

Additional information as vinyl graphics located underneath department name

Distinct color of department repeated as part of the consistent visual vocabulary

Distinct color unique to this department. Preferably using a pronounce-able color

1 TYP

Department Entry Scale NTS

2 TYP

Reception Desk Scale NTS

10.2010


63

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Door Mounted Safety Informational [DS]

Door 6”

.25”

.125”

1/8” Spacer Panel

6”

Spacer

Routed edges View

Insert Holder .25”

3F Varia Ecoresin Style: White Out FF: Supermatte BF: Supermatte

Insert slot

View

Radiation III

Ecoresin insert holder

Routed edges

Protective Panel — Clear acrylic with routed and polished edges

Contents & Activity

.375”

.375”

.375”

1

Layout Detail (Single Insert)

2

Side View

3

Plan View

DS

Scale 1:2

DS

Scale 1:2

DS

Scale 1:2 10.2010


64

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Door Mounted Safety Informational [DS]

High Voltage Zone Additional Information

Additional Insert printed with precise cautionary details or instructions

Card stock insert

Ra Insert for main message

1

Layout Detail (Double Arrangement)

DS

Scale NTS

Supplementary information on adjacent insert; option to use for billingual information

dia

tio n Co

nte

nt s

&A

III

c tiv

it y

Ey eP

rot Re ecti qu o n ire d

Clear acrylic slides down into Insert Holder

3F Varia Ecoresin routed to form an Insert Holder

Restricted Zone

Radiation III Contents & Activity

Eye Protection Required

Eye Wash Available

2

Layout Detail (4-Up Arrangement)

3

Isometric

DS

Scale NTS

DS

Scale NTS 10.2010


65

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Door Mounted Safety Informational [DS]

Restricted Zone

High Voltage Zone

Radiation III Contents & Activity

Additional Information

Eye Protection Required

Eye Wash Available

1

Layout Detail (1-Up Arrangement)

4

Layout Detail (4-Up Arrangement)

DS

Scale NTS

DS

Scale NTS

Restricted Zone

High Voltage Zone ADDITIONAL INFORMATION

Restricted Zone

High Voltage Zone ADDITIONAL INFORMATION

Radiation Iii CONTENTS & ACTIVITY

CONTENTS & ACTIVITY

Spontaneously Combustible

Spontaneously Combustible

1.25�

High Voltage Zone

Radiation

Gloves Required

Eye Protection Required

Eye Wash Available

Chemical Shower Available

Additional Insert printed with precise cautionary details or instructions

Additional Information

Gloves Required

Eye Protection Required

2

Layout Detail (2-Up Arrangement)

5

Layout Detail (6-Up Arrangement)

DS

Scale NTS

DS

Scale NTS

Restricted Zone

High Voltage Zone ADDITIONAL INFORMATION

Restricted Zone

Radiation III Contents & Activity

Radiation Iii CONTENTS & ACTIVITY

Spontaneously Combustible

Eye Protection Required

Gloves Required

Eye Protection Required

Eye Wash Available

Chemical Shower Available

3

Layout Detail (3-Up Arrangement)

6

Layout Detail (8-Up Arrangement)

7

Typical Elevation

DS

Scale NTS

DS

Scale NTS

DS

Scale 1:20 10.2010


66

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Insert Holders (IH)

Insert

Adhere sign directly to wall

White painted masking border

1/16” Clear acrylic, polished edges; masking border painted in white on second surface

11.25”

1/16” Frosted polycarbonate; cut to shape as pocket for inserts and hidden behind masking border

.25”

1/8” Frosted polycarbonate

Insert Total display area is 10.75” x 8.25”. Letter size insert is visually insetted .125” within the masking border

8.75”

Wall

Insert

View

.75” .75” .25” .25”

Vertical Placement

Finger slot

Horizontal Placement

1

Insert Holder — 8.5” x 11”

2

Side View

IH

Scale 1:4

IH

Scale 1:4

10.2010


67

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Large Insert Holders (IL)

Adhere sign directly to wall White painted masking border

1/16” Clear acrylic, polished edges; masking border painted in white on second surface

17.25”

1/16” Frosted polycarbonate; cut to shape as pocket for inserts and hidden behind masking border

.25”

1/8” Frosted polycarbonate

Total display area is 16.75” x 10.75”. Letter size insert is visually insetted .125” within the masking border

11.25”

View

Insert

.75” .75” .25” .25”

1

Large Insert Holder —11” x 17”

2

Side View

IL

Scale 1:4

IL

Scale 1:4

10.2010


Code Required Signs Sign Detail and Application


69

Sign Codes

Ohio State University Medical Center Columbus | Ohio

Signage Related Code Compliance Code Required Signs

This effort identifies the four codes applied to this project and excerpts the text related to signage from each document. These excerpts are displayed

2007 Ohio Building Code An Amended Version of the 2006 International Building Code

next to the drawing of the resultant compliant sign. These assumed answers should be reviewed for approval by the project code consultant. They should also be submitted to the client for review for compliance with any idiosyncratic, internal rules unknown to us. Finally, these signs should be

ICC/ANSI A117.1 - 1998 Accessible and Usable Buildings and Facilities as Adopted and Amended by Chapter 11 of the 2007 Ohio Building Code

offered to the Fire Marshall with authority over this site.

NFPA 101 Life Safety Code, 2000 and 2006 As Enforced by Centers for Medicare and Medicaid Services (CMS) and The Joint Commission on Accreditation of Healthcare Organizations (TJC)

ADAAG For Titles I (Employees) and III (Public Accommodation)

10.2010


70

Braille

Ohio State University Medical Center Columbus | Ohio

Codes and Examples ANSI 117.1 — 1998

4 Digit Room Numeral

Braille

Letter Prefix

Type Braille shall be contracted (Grade 2) Braille.

Signals building name

P1234A

Dimensions Braille dots shall have a domed or rounded shape and shall comply with Table 703.4.3 (below).

Distance between dots in adjacent cell Single Braille cell

Distance between dots in the same cell Distance between corresponding dots from one cell directly below

a room (also “T” for toilet, “M” for mechanical, “J” for janitorial). Exception: No “O” or “I” to avoid confusion with zero or one.

Braille Position Braille shall be below the corresponding text. If text is multi-lined, Braille shall be placed below entire text. Braille shall be separated 3 /8 inch (9.5 mm) minimum from any other tactile characters and 3/8 inch (9.5 mm) minimum from raised borders and decorative elements. Braille provided on elevator car controls shall be separated 3/16 inch (4.8 mm) minimum either directly below or adjacent to the corresponding raised characters or symbols.

Distance between dots in the same cell

Letter Suffix for labeling room inside

5 Digit Room Numeral

If we change to 5 digit room numeral the floor can be incorporated (and

P19.123A

signaled by a dot or dash between

12140 floor number and room number).

P1234A

Blank cell space between words Raised dot

Dot diameter No raised dot

3/8”

Table 703.4.3 10.2010


71

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Room Number [RN] and Room Insert [RI] ANSI 117.1 — 1998 Tactile Characters Depth: Must be raised 1/32” (0.8 mm) minimum.

P12345

Case: All uppercase. Indication of an uppercase letter or letters shall only be used before the first word of sentences, proper nouns and names, individual letters of the alphabet, initials, Tactile Room Number

or acronyms. Style: San serif (no italic, oblique, script or decorative). Height: 5/8” (16 mm) height minimum.

5.625”

2” (51 mm) height maximum. Use uppercase “I” to determine character height. Exception: Can be 1/2” (13mm) if tactile and visual characters provide the same information. Width: Characters shall be 55% minimum and 110% maximum width of the uppercase character height. Use uppercase “O” to

2.75”

determine character width.

P12345

Character Spacing: Character spacing shall be measured

1/8” EcoResin Back Plate

Hemo Oncology

Clear Engraving Stock Silk screened on surface only, leaving sides clear. Matte finish in PMS 425. 1/16” thick.

Dr. Mallisu Dr. York

View ADA compliant braille

between the two closest points of adjacent tactile characters within a message, excluding word spaces. Spacing between

Braille

individual tactile characters shall be 1 /8 inch (3.2 mm) minimum measured at the top surface of the characters, 1 /16 inch (1.6 mm) minimum measured at the base of the characters, and four times the tactile character stroke width maximum. Characters shall be separated from raised borders and decorative elements 3 /8 inch (9.5 mm) minimum.

Room Available

Line Spacing: Spacing between the base lines of separate lines of tactile characters within a message shall be 135% minimum and 170% maximum of the tactile character height. Finish and Contrast: Characters and their background shall have a non-glare finish. Characters shall contrast with their background, with either light characters on a dark background, or dark characters on a light background.

1 RN

Room Sign [RN] — Room Number Only

2

Room Sign [RI] — Room Number with Inserts

Scale 1:2

RI

Scale 1:2

10.2010


72

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Room Insert [RI] Color Adaptation and Layouts Using visual coding of signs to overcome visual clutter. Messages are presented with a consistent color-coding. Requires consistent look of message vehicles and message layouts — it is the coloration of codes.

P09156

P15153

P12008

P12345

Examination Room

Nurse’s Station

Emergency Supplies

Emergency Supplies

Dressing Room and Restroom

Check In Prior to Entry

Fire Extinguishers Backup Batteries Portable Life Support Devices

Fire Extinguishers Backup Batteries Portable Life Support Devices

Messages to Public

P12033

Messages for Practitioners

P13451

Pathology Lab

CT Scanner

Biohazard Materials. Do Not Enter Without Protective Gear. Unauthorized Personnel Not Permitted

High Radiation Area Do Not Enter Without Protective Gear

Caution Attention Messages

Hazard Warning Messages

Life Safety Messages

P10106 Critical Care Surgery Room Disinfectant Procedure and Surgical Attire Required Prior to Entering Room

Equipment Requirement Messages

Life Safety Messages

P04181 Surgical Supplies Surgery Scrubs and Other Auxiliary Supplies

Equipment Availability Messages 10.2010


73

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Retrofitted Room Insert [RI] Note: This layout is designed specifically for use in ProjectONE. 5.625”

P12345

2.75”

1/8” EcoResin Back Plate

.625”

Clear Engraving Stock Silk screened on surface only, leaving sides clear. Matte finish in PMS 425. 1/16” thick.

1”

.375”

ADA compliant braille

Braille .375” .25”

Raised insert display .375”

Hemo Oncology Dr. Mallisu Dr. York

White painted masking border

1/16” Paper Insert Spacer 1/8” Acrylic Spacer

Quarter page of an 8.5” x 11” size paper; use medium cover stock paper or regular folded sheet

View 4”

5.75”

1/16” Paper Insert Spacer Main insert display window

.75”

.25”

Patient advisory window

Room Available

1”

.75”

1/8” Clear acrylic, polished edges; paint white masking border on second surface

Edges of insert are hidden behind masking border

.25”

5.375” .25”

1 RI

1/16” Paper Insert Spacer

Finger slot

Retrofitted Room Insert [RI]

2

Isometric

Scale 1:2

RI

Scale: NTS

Patient advisory insert

10.2010


74

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Retrofitted Room Insert [RRI] Note: This is a retrofitted design (usage optional) and is its size 7.75”

and layout based on existing signage currently in use on campus. Requested by client in design review meeting on 10.15.2010.

P12345

2.75”

.625”

1/8” EcoResin Back Plate Clear Engraving Stock Silk screened on surface only, leaving sides clear. Matte finish in PMS 425. 1/16” thick.

1”

.375”

ADA compliant braille .375”

.375”

Raised insert display

Hemo Oncology

1/8” Acrylic Spacer

1/16” Paper Insert Spacer

Dr. Mallisu Dr. York

White painted masking border

Quarter page of an 8.5” x 11” size paper; use medium cover stock paper or regular folded sheet

View 4.125”

6.25” .5”

Main insert display window

.75”

.375”

Room Available

Patient advisory window

1/8” Clear acrylic, polished edges; paint white masking border on second surface

1”

Edges of insert are hidden behind painted masking border

.375”

1/16” Paper Insert Spacer Patient advisory insert

7.25” .5”

1 RRI

Retrofitted Room Insert [RI] Scale 1:2

Finger slot

2

Isometric

RRI

Scale: NTS

10.2010


75

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Patient Room Sign [PR] Patient Room Sign with Slidable Patient Care Placards

Patient Care Placards and Paper Grip Rail

Tactile and Braille header indicating room number with a window for paper insert. When placards are not in use, they are hidden from view.

Patient care information icons are displayed on placards that can be locked or unlocked, slide in or out, and customizable as needed per department or unit. Additional notes or documents regarding the occupant can be attached to a paper grip rail located at the bottom of the sign. Patient care placards

5.625”

2.75”

P12345

P12345 npo

Critical Care Unit 5.75”

Patient’s Name Doctor’s Name (AM) Doctor’s Name (PM) Nurses’ Names

Option: Face of sign fabricated as a single hinged flap to open for further messages; paper grip removed

P12345

Critical Care Unit

npo

Critical Care Unit Patient’s Name Doctor’s Name (AM) Doctor’s Name (PM) Nurses’ Names

Patient’s Name Doctor’s Name (AM) Doctor’s Name (PM) Nurses’ Names

18” See ANSI 117.1 installation requirements

.5” Possible medication side effects include: "Sed ut perspiciatis unde omnis iste natus error sit voluptatem accusantium doloremque laudantium, totam rem aperiam, eaque ipsa quae ab illo inventore veritatis et quasi architecto beatae vitae dicta sunt explicabo. Nemo enim ipsam voluptatem quia voluptas sit aspernatur aut odit aut fugit, sed quia.

Additional information of this signtype can be found at www.lhsigns.com

Paper grip rail under signs at key location

Extra surface for messages

Notes regarding room can be attached

Patient Care Sign

Patient Care Sign

Typical Elevation

Scale: 1:3

Scale: 1:3

Scale: 1:25

10.2010


76

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Stairway Identification [SI] ANSI 117.1 — 1998 Pictogram Field

Tactile Legend

Same as for pictogram signs if pictograms are used. Tactile Characters

Ecoresin® or frosted polycarbonate

6.125”

Refer to specifications on Tactile and Braille page. Braille

.5”

West Stair C

Refer to specifications on Tactile and Braille page.

1/16”

West Stair C

IBC — 2006

.625”

.375”

.25”

1011.3 Tactile Exit Signs A tactile sign stating EXIT and complying with ICC A117.1

4.125”

shall be provided adjacent to each door to an area of refuge, an exterior area for assisted rescue, an exit stairway, an exit ramp, an exit passageway and the exit discharge.

West Stair C

NFPA 101 — 2006 10.5”

7.10.1.3 Exit Door Tactile Signage

3.5”

EXIT

Tactile signage shall be provided to meet the following criteria, unless otherwise provided in 7.10.1.4: (1) Tactile signage shall be located at each exit door requiring an exit sign. (2) Tactile signage shall read as follows: EXIT. (3) Tactile signage shall comply 18”

7.2.2.5.4 Stairway Identification

EXIT

Stair identification needs to be letters not numbers. These signs to be located on the occupancy or entrance side of the stairwell.

EXIT

.25”

.75”

Braille

See ANSI 117.1 installation requirements

.625” .375”

Clear Engraving Stock Printing on surface only, leaving sides clear. Matte finish paint. 1/16” thick.

.25”

Front View

Basic Layout — Front and Side View

Typical Elevation

Scale: 1:3

Scale: 1:3

Scale: 1:25

10.2010


77

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Stair Sign [SS] NFPA 101 — 2006 7.2.2.5.4* Stairway Identification 7.2.2.5.4.1 New enclosed stairs serving three or more stories

(K)* Signage that reads NO ROOF ACCESS and is located under

and existing enclosed stairs serving five or more stories shall

the stairway identification letter shall designate stairways that

comply with 7.2.2.5.4.1(A) through (M).

do not provide roof access. Lettering shall be a minimum of

Stair East

1 in. (25 mm) high and shall be in accordance with 7.10.8.2.

15

(A) The stairs shall be provided with special signage within the enclosure at each floor landing.

(L) The floor level number shall be located in the middle of the sign in minimum 5 in. (125 mm) high numbers and shall be in

(B) The signage shall indicate the floor level.

accordance with 7.10.8.2. Mezzanine levels shall have the letter “M” or other appropriate identification letter preceding

(C) The signage shall indicate the terminus of the top and

the floor number, while basement levels shall have the letter “B”

bottom of the stair enclosure.

or other appropriate identification letter preceding the floor level number.

(D) The signage shall indicate the identification of the stair enclosure.

(M) Identification of the lower and upper terminus of the stairway shall be located at the bottom of the sign in minimum

(E) The signage shall indicate the floor level of, and the direction

1 in. (25 mm) high letters or numbers and shall be in accordance

to, exit discharge.

with 7.10.8.2.

(F) The signage shall be located inside the enclosure

7.2.2.5.4.2 Wherever an enclosed stair requires travel in an

approximately 60 in. (1525 mm) above the floor landing in a

upward direction to reach the level of exit discharge, special

position that is visible when the door is in the open or closed

signs with directional indicators showing the direction to the

position.

level of exit discharge shall be provided at each floor level

Re-Entry on L5-10 Down to 1ST Floor For Exit Discharge

landing from which upward direction of travel is required, unless (G) The signage shall comply with 7.10.8.1 and 7.10.8.2 of this

otherwise provided in 7.2.2.5.4.2 (A) and 7.2.2.5.4.2(B), and

Code.

the following also shall apply: (1) Such signage shall comply with 7.10.8.1 and 7.10.8.2.

(H) The floor level designation shall also be tactile in accordance

(2) Such signage shall be visible when the door leaf is in the

with ICC/ANSI A117.1, American National Standard for

open or closed position.

Accessible and Usable Buildings and Facilities. (A) The requirement of 7.2.2.5.4.2 shall not apply where signs (I) The signage shall be painted or stenciled on the wall or on a

required by 7.2.2.5.4.1 are provided.

separate sign securely attached to the wall. (B) The requirement of 7.2.2.5.4.2 shall not apply to stairs (J) The stairway identification letter shall be located at the top

extending not more than one story below the level of exit

of the sign in minimum 1 in. (25 mm) high lettering and shall be in

discharge where the exit discharge is clearly obvious.

accordance with 7.10.8.2.

Front View Scale: 1:3

10.2010


78

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Stairway Identification [SI]

6.125”

Stair East

Tactile Type

.5”

15

Braille

Tactile Level Number 12.25”

Tactile Type

.375”

1”

1”

1/8” Spacer

.75”

Stair East

15

5”

Re-Entry on L5-10 Re-Entry on L5-10 Down to 1 ST Floor For Exit Discharge

Clear Acrylic with Painted Face

1”

Re-Entry on L5-10 Down to 1ST Floor For Exit Discharge

Tactile Type

Ecoresin® or frosted polycarbonate

.25”

Clear Engraving Stock Printing on surface only, leaving sides clear. Matte finish paint. 1/16” thick.

.625”

18” See ANSI 117.1 installation requirements

1.625”

.25”

Basic Layout — Front and Side View

Typical Elevation

Scale: 1:3

Scale: 1:25

10.2010


79

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Elevator Landing Signs [EL] IBC — 2006 7.10.8.4 Elevator Signs Elevators that are a part of a means of egress (see 7.2.13.1) shall have the following signs with a minimum letter height of 3”

5/8” (16 mm) posted in every elevator lobby: (1)* Signs that indicate that the elevator can be used for egress,

Ecoresin® or frosted polycarbonate

Silk screened typography and graphics

including any restrictions on use;

In Fire Emergency, Do Not Use Elevator. Use Exit Stairs.

(2)* Signs that indicate the operational status of elevators.

7.10.8.5* Evacuation Map Where a posted floor evacuation map is required in Chapters 11 through 43, floor evacuation diagrams reflecting the actual floor

In Fire Emergency, Do Not Use Elevator. Use Exit Stairs.

1/8” Backer Panel .5”

1/8” Spacer

1.5”

arrangement and exit locations shall be posted and oriented in a

Evacuation Map

location and manner acceptable to the authority having jurisdiction.

15.75”

View

8.5”

Clear acrylic window

Map Insert Standard size 8.5” x 11” paper folded in half

Insert slot

5.5”

.375”

Basic Layout

Front and Side View

Scale: 1:3

Scale: 1:3

.25”

10.2010


80

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Pictogram Signs/ Restroom Signs [RS] ANSI 117.1 — 1998 Tactile Characters Refer to specifications on Tactile and Braille page. Braille Refer to specifications on Tactile and Braille page. Pictogram Field Pictograms shall have a field 6 inches (150 mm) minimum in height. Characters or Braille shall not be located in the pictogram field. Finish and Contrast Pictograms and their fields shall have a non-glare finish. Pictograms shall contrast with their fields, with either a light pictogram on a dark field or a dark pictogram on a light field. Text Descriptors Where text descriptors for pictograms are required, they shall be located directly below the pictogram field. Finish and Contrast Symbols of accessibility and their backgrounds shall have a non-glare finish. Symbols of accessibility shall contrast with their backgrounds, with either a light symbol on a dark background or a dark symbol on a light background.

MEN

WOMEN

Front View Scale: 1:2

10.2010


81

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Pictogram Signs/ Restroom Signs [RS] 5.25”

.25”

Ecoresin® or frosted polycarbonate

Clear Engraving Stock Printing on surface only, 3.5”

leaving sides clear. Matte

6”

finish in PMS 425. 1/16” thick. View WOMEN

8.75”

Backer Panel 1/8” 18”

Spacer

WOMEN

1/8” .625”

See ANSI 117.1 installation requirements

Clear Engraving Stock

.375” .25”

.75”

Front View

Typical Elevation

Scale: 1:2

Scale: 1:25

10.2010


82

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Tactile Exit Signs [TE] IBC — 2006 5.25”

1011.3 Tactile Exit Signs

.25”

A tactile sign stating EXIT and complying with ICC A117.1 shall be provided adjacent to each door to an area of refuge, an exterior area for assisted rescue, an exit stairway, an exit ramp, an exit passageway and the exit discharge.

NFPA 101 — 2006

Ecoresin® or frosted polycarbonate

7.10.1.3 Exit Door Tactile Signage Tactile signage shall be provided to meet the following criteria, unless otherwise provided in 7.10.1.4: (1) Tactile signage shall be located at each exit door requiring an exit sign.

Clear Engraving Stock

(2) Tactile signage shall read as follows: EXIT.

Printing on surface only,

(3) Tactile signage shall comply

6”

3.5”

leaving sides clear. Matte finish in PMS 425. 1/16” thick.

7.2.2.5.5.8 Emergency Exit Symbol An emergency exit symbol with a luminescent background

8.75”

shall be applied on all doors serving the exit enclosure that swing out from the enclosure in the direction of egress travel. The emergency exit symbol shall also meet the following requirements:

1/8” Backer Panel

(1) The emergency exit symbol shall meet the requirements of NFPA 170, Standard for Fire Safety and Emergency Symbols. (2) The emergency exit symbol applied on the door shall be not

1/8” Spacer

higher than 18 in. (455 mm) above the finished floor.

EXIT

ANSI 117.1 — 1998

EXIT

Pictogram Field: Same as for pictogram signs if pictograms are

.625”

Clear Engraving Stock

.25”

used. Tactile Characters: Refer to specifications on Tactile and Braille page.

.75”

Braille: Refer to specifications on Tactile and Braille page.

Front View

Basic Layout — Front and Side View

Scale: 1:2

Scale: 1:2

10.2010


83

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Area of Refuge [AR] IBC — 2006 1007.11 Instructions 1007.9 Signage

In areas of refuge and exterior areas for assisted rescue,

Signage indicating special accessibility provisions shall be

instructions on the use of the area under emergency

provided as shown:

conditions shall be posted. The instructions shall include all of the following:

1. Each door providing access to an area of refuge from an adjacent floor area shall be identified by a sign stating:

1. Persons able to use the exit stairway do so as soon as

AREA OF REFUGE.

possible, unless they are assisting others.

2. Each door providing access to an exterior area for

2. Information on planned availability of assistance in the

assisted rescue shall be identified by a sign stating:

use of stairs or supervised operation of elevators and how to

EXTERIOR AREA FOR ASSISTED RESCUE.

summon such assistance.

Signage shall comply with the ICC A117.1 requirements

3. Directions for use of the two-way communications

for visual characters and include the International Symbol

system where provided.

7”

.25”

Area of Refuge

Ecoresin® or frosted polycarbonate

Clear Engraving Stock Printing on surface only,

of Accessibility. Where exit sign illumination is required by Section 1011.2, the signs shall be illuminated.

leaving sides clear. Matte

1011.2 Illumination Exit signs shall be internally or externally illuminated.

View

8.75”

finish paint. 1/16” thick.

Additionally, tactile signage complying with ICC A117.1 shall be located at each door to an area of refuge and

Exception: Tactile signs required by Section 1011.3 need

exterior area for assisted rescue in accordance with

not be provided with illumination.

1/8” Backer Panel 1/8” Spacer

Section 1011.3. 1011.3 Tactile Exit Signs 1007.10 Directional Signage

A tactile sign stating EXIT and complying with ICC A117.1

Direction signage indicating the location of the other

shall be provided adjacent to each door to an area of refuge,

means of egress and which are accessible means of

an exterior area for assisted rescue, an exit stairway, an exit

egress shall be provided at the following:

ramp, an exit passageway and the exit discharge.

EXIT

Clear Engraving Stock

1. At exits serving a required accessible space but not providing an approved accessible means of egress. 2. At elevator landings. 3. Within areas of refuge.

International Symbol of Accessibility

Front and Side View Scale: 1:3

10.2010


84

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Two-Way Communication [TC] IBC — 2006 1007.6.3 Two-way Communication Areas of refuge shall be provided with a two-way communication system complying with Sections 1007.8.1 and 1007.8.2.

Clear Engraving Stock Printing on surface only, leaving sides clear. Matte finish paint. 1/16” thick.

1007.8 Two-way Communication A two-way communication system shall be provided at the elevator landing on each accessible floor that is one or more stories above or below the story of exit discharge complying with

.25”

5.25”

Sections 1007.8.1 and 1007.8.2. Exceptions:

In the event of emergency, this phone will provide direct contact to security and emergency personnel.

1. Two-way communication systems are not required at the elevator landing where the two-way communication system is provided within areas of refuge in accordance with Section 1007.6.3. 2. Two-way communication systems are not required on floors provided with exit ramps conforming to the provisions of Section 1010.

3.25”

7”

In the event of emergency, this phone will provide direct contact to security and emergency personnel.

Backer Panel Spacer

View

Emergency Phone

1007.8.1 System Requirements Two-way communication systems shall provide communication between each required location and the fire command center or a central control point location approved by the fire department.

.625”

Emergency Phone

Clear Engraving Stock

.25”

Where the central control point is not constantly attended, a two-way communication system shall have a timed automatic telephone dial-out capability to a monitoring location or 911. The two-way communication system shall include both audible and visible signals.

.75”

Ecoresin® or frosted polycarbonate

1007.8.2 Directions Directions for the use of the two-way communication system, instructions for summoning assistance via the two-way communication system and written identification of the location shall be posted adjacent to the two-way communication system.

Front View

Basic Layout — Front and Side View

Typical Elevation

Scale: 1:3

Scale: 1:3

Scale: 1:25

10.2010


85

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Stairway Level Marker [SL] ANSI 117.1 — 1998 Tactile Characters Refer to specifications on Tactile and Braille page. Braille Refer to specifications on Tactile and Braille page. IBC — 2006 Need specific code references. NFPA 101 — 2006 7.2.2.5.4 Stairway Identification (H) The floor level designation shall also be tactile in accordance with ICC/ANSI A117.1, American National

3.5”

10

3”

Standard for Accessible and Usable Buildings and Facilities.

10

Typical Sign Layout

1 Egress Level Layout

18”

Typical Elevation

10.2010


86

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Occupant Load [OS] IBC — 2006 1004.3 Posting of Occupant Load Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent.

3.5”

Maximum Occupancy

50

3.5”

Maximum Occupancy

100

Front View

Basic Layout

Scale: 1:2

Scale: 1:2

10.2010


87

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Tactile No Exit Signs [NE] NFPA — 2006 7.10.8.3* No Exit

Clear Engraving Stock Printing on surface only, leaving sides clear. Matte finish paint. 1/16” thick.

7.10.8.3.1 Any door, passage, or stairway that is neither an exit nor a

5.25”

way of exit access and that is located or arranged so that

.25”

it is likely to be mistaken for an exit shall be identified by a sign that reads as follows:

NO EXIT

Ecoresin® or frosted polycarbonate

7.10.8.3.2 The NO EXIT sign shall have the word NO in letters 2 in.

6” Pictogram Field

3.5”

(51 mm) high, with a stroke width of 3/8 in. (9.5 mm), and the word EXIT in letters 1 in. (25 mm) high, with the word

View

EXIT below the word NO, unless such sign is an approved existing sign.

10.5”

NO EXIT

NO EXIT

1/8” Backer Panel

1/8” Spacer

2”

Clear Engraving Stock

1”

.25”

.75”

Front View

Basic Layout — Front and Side View

Scale: 1:3

Scale: 1:3

10.2010


88

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Delayed Egress Door Signs [DE] NFPA 101 — 2006 Tactile exit sign required

7.2.1.6.1 Delayed-Egress Locking Systems (5)* A readily visible, durable sign in letters not less than 1 in. (25 mm) high and not less than 1/8 in. (3.2 mm) in stroke

Vinyl adheres to door

width on a contrasting background that reads as follows shall be located on the door leaf adjacent to the release device: PUSH UNTIL ALARM SOUNDS DOOR CAN BE OPENED IN 15 SECONDS Align right (strike side of door)

1” .75”

PUSH UNTIL ALARM SOUNDS DOOR CAN BE OPENED IN 15 SECONDS

EXIT

1”

.125”

7”

.75”

Length of door bar

Front View

Typical Elevation

Scale: 1:5

Scale: 1:25

10.2010


89

Materials & Detail Design

Ohio State University Medical Center Columbus | Ohio

Powered Door Leaf Signs [PD] NFPA 101 — 2006 7.2.1.9* Powered Door Leaf Operation 7.2.1.9.1* General. Where means of egress door leaves are operated by power upon the approach of a person

Tactile exit sign required

or are provided with power-assisted manual operation, the design shall be such that, in the event of power failure, the leaves open manually to allow egress travel

Vinyl adheres to door

or close when necessary to safeguard the means of egress. 7.2.1.9.1.1 The forces required to manually open the door leaves specified in 7.2.1.9.1 shall not exceed those required in 7.2.1.4.5, except that the force required to set the leaf in motion shall not exceed 50 lbs. (222 N). 1”

7.2.1.9.1.2 The door assembly shall be designed and

.75”

installed so that, when a force is applied to the door leaf on the side from which egress is made, it shall be capable of swinging from any position to provide full use of the required width of the opening in which it is

1”

IN EMERGENCY, PUSH TO OPEN

EXITEXIT

.125”

installed. (See 7.2.1.4.) 7.2.1.9.1.3 A readily visible, durable sign in letters not less than 1 in. (25 mm) high on a contrasting

Length of door bar

background that reads as follows shall be located on the egress side of each door opening: IN EMERGENCY, PUSH TO OPEN 7.2.1.9.1.4 Sliding, power-operated door assemblies in an exit access serving an occupant load of fewer than 50 that manually open in the direction of door leaf travel, with forces not exceeding those required in 7.2.1.4.5, shall not be required to have the swing-out feature required by 7.2.1.9.1.2. The required sign shall be in letters not less than 1 in. (25 mm) high on a

Powered Door Leaf Signs

Typical Elevation

contrasting background and shall read as follows: IN EMERGENCY, SLIDE TO OPEN 10.2010


90

Installation

Ohio State University Medical Center Columbus | Ohio

Wall Mounting Scenarios Note: The preferred method of installation is OPTION A. Choice of installation method based on sign location’s circumstances and should be attempted in the order of A,B,C and D until sign is successfully installed.

3”

3”

3”

Large Conference Room

PREFERRED METHOD

1 TYP

Install sign on strike side of door. Allow 3” from obstruction to right edge of sign but no more than 18“ from edge of door frame. 60” from top of sign to finished floor.

Install sign on strike side of door. Allow 3” from edge of door frame and 60” from top of sign to finished floor.

Preferred Installation — Option A Scale 1:30

2 TYP

Installation — Option B Scale 1:30

60”

P1245

Large Conference Room

60”

P1245

Large Conference Room

60”

P1245

Large Conference Room

60”

P1245

Install sign on opposite to strike side of door. Allow 3” from door frame or obstruction to left edge of sign but no more than 18“ from edge of door frame. 60” from top edge of sign to finished floor.

3 TYP

Installation — Option C Scale 1:30

Install sign directly on door if both sides are obstructed. Center sign on door and 60” from top edge of sign to finished floor.

4 TYP

Installation — Option D Scale 1:30 10.2010


91

Installation

Ohio State University Medical Center Columbus | Ohio

Mounting Water Line

Installation Height West Stair C

WOMEN

EXIT EXIT

Stair East

15

P1245

P1245 P1245 Examination Room Laboratory Descriptions Here

12300

In Fire Emergency, Do Not Use Elevator. Use Exit Stairs. Evacuation Map

Critical Care Unit Patient’s Name Doctor’s Name (AM) Doctor’s Name (PM) Nurses’ Names

Re-Entry on L5-10 Down to 1 ST Floor For Exit Discharge

43”

60”

Installation Height

1

Installation Height of Wall Mounted Signs Scale 1:30 10.2010


92

Enhanced Experience: Possible Additions to the Program (TBD)

Ohio State University Medical Center Columbus | Ohio

Adding Value for Building Occupants Station ID

Monitor Display

Vision Screen

Dimensional address at each station with room directory at this station

Loop of all necessary ID and wayfinding content

Translucent glass graphics positioned at eye level for privacy but presented in an artful way

Vinyl Numeral At patient room door

Graphic Art Mural

WEST PATIEN

T BAY “To wish to be well is a part of becoming well.” — Seneca

m I nfo r

Light Box Visual totem offers directory/imagery messages

Wayfinding Icons

a ti o n

(All artwork shown is intended as example only; final designs TBD)

10.2010


Exterior Signage Design Intent, Locations, and Specifications


94

Exterior Signage

Ohio State University Medical Center Columbus | Ohio

Major Building Indentification and Announcers A

B A

B

C

B

The James

James Cancer Center and Solove Research Institute

Cancer Center

Primary Logo Lockup Face lit letters and graphics mounted to structural frame and attached to parapet or suitable surface. Paint structural frame to match other metallic surfaces on building to minimize visibility.

C

The James Cancer Center

James Cancer Center and Solove Research Institute

Building Name Channel letters mounted to structural frame and attached to parapet or suitable surface. Paint structural frame to match other metallic surfaces on building to minimize visibility. Face lit letters with LED.

D

Emergency

Emergency entrance is located at the North facade of building

Emergency Entrance Sign and Cross Graphic This sign marks the entrance to the Emergency unit on the North facade only. Channel letters and cross graphic are both face and back lit for enhanced visiblity. Mount to building canopy.

E

D

Emergency

Arthur G. James Cancer Center & Richard J. Solove Research Institute

E

Arthur G. James Cancer Center & Richard J. Solove Research Institute

Street Level Building Name Stainless steel with satin finish mounted to exterior surface of building visible to pedestrian and vehicular traffic. Use halo illumination to acheive visibility at night. Location TBD.

Note: Diagram only; sizes, locations, and proportion are approximations only.

1

West Facade

2

South Facade

ES

Scale NTS

ES

Scale NTS

10.2010


95

Exterior Signage

Ohio State University Medical Center Columbus | Ohio

Primary Logo Lockup

Logo Graphic Using 3M Panaflex Material and SignComp Bleed Tension Frame

Logo Lockup (Entire Sign)

Logo Graphic

Part number: 2085 and 2095

Logotype (Letters)

2

3

PL

PL

Multiple rows of white LEDs as required for bright and even illumination

Corner key Frame brace Structural frame (horizontal beam)

Frame corner angle

Graphic output on 3M Panaflex translucent film

Attachment fastener

Frame painted to match color of metallic surfaces on building to minimize visibility

Structural frame (horizontal beam)

Backlit channel letters. 1/8" thick clear acrylic faces with 3M Dual Color film on the 2nd surface

Graphic output on 3M Panaflex

approx. 120�

1

Emergency Signage

2

Section View

PL

Scale NTS

PL

Scale NTS

10.2010


96

Exterior Signage

Ohio State University Medical Center Columbus | Ohio

Primary Logo Lockup Logo Graphic / Logotype Using Channeling and Face Lit LED Illumination This portion of logo lockup uses rigid, face lit channeling light box (area outlined in blue stroke)

Frame uses steel angle structure over parapet as required

This portion of logo lockup uses rigid, face lit channeling letters (area outlined in blue stroke)

Galvanized steel angle clips with stainless steel hardware

Multiple rows of white LEDs as required for bright and even illumination

All inside surfaces painted with light enhancement paint (LEP)

Secondary electrical conduit to remote transformers inside the hospital. All secondary electrical to be installed and penetrations waterproofed prior to installation of the insulation, sheathing and internal metal panels

Building

Returns painted to match color of adjacent surfaces on logo

Portion of logo lockup to use flexible 3M Panaflex translucent film and face lit with LED (area outlined in red stroke)

Connect electrical wiring to raceway frame

3

Section View

4

Logo Lockup

PL

Scale NTS

PL

Scale NTS

10.2010


97

Exterior Signage

Ohio State University Medical Center Columbus | Ohio

Primary Logo Lockup

Stainless steel frame providing base structure for logo elements and attaches to building

Daylight sensors or master programmable timing controls activate lighting

Face of the logotype (Medical Center) glows white at night

5

Isometric View

6

Night Illumination

PL

Scale NTS

PL

Scale NTS

10.2010


98

Exterior Signage

Ohio State University Medical Center Columbus | Ohio

Primary Logo Lockup

2

3

PL

PL

This portion of logo lockup uses rigid, face lit channeling light box (area outlined in blue stroke)

This portion of logo lockup uses rigid, face lit channeling letters (area outlined in blue stroke)

Portion of logo lockup to use flexible 3M Panaflex translucent film and face lit with LED (area outlined in red stroke) Backlit channel letters. 1/8" thick clear acrylic faces with 3M Dual Color film on the 2nd surface

Frame painted to match color of metallic surfaces on building to minimize visibility

3

The James PL

Cancer Center

Backlit channel letters. 1/8" thick clear acrylic faces with 3M Dual Color film on the 2nd surface

This portion of logo lockup uses rigid, face lit channeling letters (area outlined in blue stroke)

TBD�

1 PW

Primary Logo on West Facade Scale NTS

2 PW

Components of Signage Scale NTS

10.2010


99

Exterior Signage

Ohio State University Medical Center Columbus | Ohio

Primary Logo Lockup

Stainless steel frame providing base structure for logo elements and attaches to building

Daylight sensors or master programmable timing controls activate lighting

Face of the logotype (Medical Center) glows white at night

Face of the logotype (The James Cancer Center) glows white at night

3 PW

Isometric View Scale NTS

4 PW

Night Illumination Scale NTS

10.2010


100

Exterior Signage

Ohio State University Medical Center Columbus | Ohio

Building Name — Top of Building

approx. 6� Steel angle structure over parapet as required

Galvanized steel angle clips with stainless steel hardware

2 BN

Returns painted to match color of adjacent surfaces on logo

James Cancer Center and Solove Research Institute

Multiple rows of white LEDs as required for bright and even illumination

Fasten steel frame to building Secondary electrical conduit to remote transformers inside the hospital. All secondary electrical to be installed and penetrations waterproofed prior to installation of the insulation, sheathing and internal metal panels

Frame painted to match color of metallic surfaces on building to minimize visibility

All inside surfaces painted with light enhancement paint (LEP)

Building

Multiple rows of white LEDs as required for bright and even illumination

Backlit channel letters. 1/8" thick clear acrylic faces with 3M Dual Color film on the 2nd surface

Connect electrical wiring to raceway frame

1 BN

Logo Lockup

2

Side View

Scale 1:20

BN

Scale NTS

10.2010


101

Exterior Signage

Ohio State University Medical Center Columbus | Ohio

Building Name — Top of Building Stainless steel frame providing base structure for logo elements and attaches to building

Parapet

Daylight sensors or master programmable timing controls activate lighting

Face of the logotype glows white at night

3

Isometric View

4

Night Illumination

BN

Scale NTS

BN

Scale NTS

10.2010


102

Exterior Signage

Ohio State University Medical Center Columbus | Ohio

Emergency Entrance Sign

Building or canopy

Galvanized steel attachment to building 2 EE

2” Acrylic in OSU Red; allow for transmission of light

Emergency

Multiple rows of white LEDs as required for bright and even illumination

5”

Multiple rows of white LEDs on opposite side allowing light spill at rear of sign 1/8" thick clear acrylic faces with 3M Diffuser film on the 2nd surface

20”

1/8" thick clear acrylic faces with 3M Dual Color film on the 2nd surface

All secondary electrical to be installed and penetrations waterproofed prior to installation of the insulation, sheathing and internal metal panels

All inside surfaces painted with light enhancement paint (LEP)

125”

Returns painted to match color of adjacent surfaces on logo Connect electrical wiring to raceway frame

Sign stands off from mounted wall for light spill from LED

Note: Measurements are estimations only.

1 EE

Emergency Signage

2

Section View

Scale 1:20

EE

Scale NTS

10.2010


103

Exterior Signage

Ohio State University Medical Center Columbus | Ohio

Emergency Entrance Sign

Painted metallic side frame in red; weatherproof sealed Daylight sensors or master programmable timing controls activate lighting

Halo illumination in addition to backlit face

White or neutral color temperature LED halo light

3

Isometric View

4

Halo Lighting Illumination

EE

Scale NTS

EE

Scale NTS

10.2010


104

Exterior Signage

Ohio State University Medical Center Columbus | Ohio

Building Name — Street Level

Returns to match stainless steel surface on face 2” 165”

20”

4”

Multiple rows of white LEDs as required for bright and even illumination

Arthur G. James Cancer Center & Richard J. Solove Research Institute

Electrical connection

Stainless steel face

All inside surfaces painted with light enhancement paint (LEP) Stainless steel face with brush, low reflectivity finish

1/8" thick clear acrylic faces with 3M Diffuser film on the 2nd surface

Sign stands off from mounted wall for light spill from LED

Multiple rows of white LEDs as required for bright and even illumination

Building/Mounting wall

1/8" thick clear acrylic faces with 3M Diffuser film on the 2nd surface Electrical connection

Stainless steel face Returns to match stainless steel surface on face

Note: Measurements are estimations only.

1 BB

Logo Lockup

2

Side View

Scale 1:25

BB

Scale NTS

10.2010


105

Exterior Signage

Ohio State University Medical Center Columbus | Ohio

Building Name — Street Level

Daylight sensors or master programmable timing controls activate lighting

Letters defined by halo illumination

Stainless steel face and return with brush, low reflectivity finish

This sign may require external lighting

3

Isometric View

4

Night Illumination

BB

Scale NTS

BB

Scale NTS

10.2010


106

Exterior Signage

Ohio State University Medical Center Columbus | Ohio

Signage Components on North Facade

Channel letters and graphic

2100

WEST 10 TH AVENUE

Physical address in stainless steel dimensional letterforms; pin mount letters to wall individually; not illuminated

Note: This is a diagramatic illustration of signage yet to be located on building facade

1

North Facade (Emergency Entrance)

ES

Scale NTS

10.2010


107

Exterior Signage

Ohio State University Medical Center Columbus | Ohio

Signage Components on South Facade

Horizontal arrangement of building name

2100

WEST 10 AVENUE TH

Physical address in stainless steel dimensional letterforms; pin mount letters to wall individually; not illuminated

Arthur G. James Cancer Center & Richard J. Solove Research Institute

Note: This is a diagramatic illustration of signage yet to be located on building facade

1

South Entry

ES

Scale NTS

10.2010


108

Exterior Signage

Ohio State University Medical Center Columbus | Ohio

Graphics at Building Entry

OSUMC logo

Arthur G. James Cancer Center Wheelchair accessible path

Richard J. Solove Wheelchair Accessible Path

THIS IS A TOBACCO-FREE CAMPUS NOTICE: VIDEO SURVELLIANCE IN USE ON THESE PREMISES.

Restrictions and policy messages

"PURSUANT TO SECTION 30.06, PENAL CODE (TRESPASS BY HOLDER OF A LICENSE TO CARRY A CONCEALED HANDGUN) A PERSON LICENSED UNDER SUBCHAPTER H, CHAPTER 411, GOVERNMENT CODE (CONCEALED HANDGUN LAW), MAY NOT ENTER THIS PROPERTY WITH A CONCEALED HANDGUN."

Research Institute

Building identity and donor recognition

Major donor’s name here Major donor’s name here

OSUMC The James is an equal opportunity employer Call 123-456-7890 for hospital staff assistance and information For translation services, call 123-456-7890 for language assistance

Other building related notices, services, wheelchair request, etc.

Note: This is a diagramatic illustration of signage yet to be located on building facade

1

Vinyl Graphics at Building Entry

VG

Scale NTS

10.2010


109

Exterior Signage

Ohio State University Medical Center Columbus | Ohio

Additional Notes Fabrication Notes on Exterior Signage: (Applicable to all exterior signage) Sign Contrator Submittal Requirements:

Letters: Internally illuminated “face lighted” channel letters with

Electrical: Remote transformers inside UL approved metals boxes

white LED illumination and white translucent acrylic faces with

to be provided by the sign contractor and located inside the

first surface applied 3M Scotchcal Dual Color (black- day/night)

building in the ceiling above removable ceiling panels. The general

film, that appear black in the daytime and illuminate white at

contractor will provide primary electrical service to this point. The

night. Faces to be secured with with aluminum angle face

sign contractor to provide all remote transformers, UL metal

retention. Letters to be fabricated with .090 aluminum backs

boxes, secondary conduit runs, electrical wiring, , installation

and .063 returns painted to match (TBD). All inside surfaces

hardware, disconnect switches, insulators, boots and any

Shop drawings

painted with light enhancement paint (LEP), white. Provide

miscellaneous components, as required for a complete

Fabricate per design drawings

appropriate waterproofing and weep holes on lower surfaces for

installation. All electrical components shall be UL approved and

lettering and logo.

the completed letters shall be inspected and bear UL approved

Face layout drawings for each sign location

labels. The electrical service shall be controlled from a central Logo Graphic: Internally illuminated “face lighted” channel

electrical panel, so photocells will not be required to control the

letters with color translucent acrylic faces with LED illumination.

illumination of the sign.

“Flame” to be fabricated with .090 aluminum backs and .063 returns with aluminum angle face retention. Returns painted to

Installation and Mounting: Coordination of the location of each

match adjacent faces on logo graphics (TBD).

building penetration will be critical and the sign contractor shall install full size rigid templates (not paper). Coordination of all

Field Verification Conditions Prior to shop drawings submittals Prior to installation Drawing Submittals

Sample Submittals Paint Samples Material samples (face acrylic & vinyl) Patterns and Templates Full size mounting templates (rigid) Full size rigid templates applied in place for approval prior to installation

Illumination: Internal illumination to be white LED modules (GE

electrical penetrations and installation of all secondary conduit

Tetra or approved equal). The number of LED module rows to be

runs during construction. This will require multiple site visits prior

determined based on the stroke width of the letter forms and

to final installation to install all secondary electrical penetrations

graphic. Illumination shall be evenly bright on all portions of each

and have these penetrations sealed and weather proofed prior to

letter form with no “hot spots” or “dark areas”. NOTE: Thin

completion of the building wall panels. All installation hardware to

portions of the letter strokes, will require more LEDs at tighter

be non-corrosive for the existing wall conditions. Isolate any

Fabricate per design drawings and approved

spacings than the manufacturers standard recommendations. A

dissimilar metals. Installation to utilize liquid-tight, flexible metal

shop drawings

full size complete prototype letter will be required to be viewed

conduit to transformers. Seal building penetrations as required by

on-site prior to fabrication.

the architect.

Fabrication Samples and Prototypes (1) full sized prototype letter for approval Prototypical installation

10.2010


110

Exterior Signage

Ohio State University Medical Center Columbus | Ohio

Previous Renderings

Previous renderings of exterior signage

10.2010


Wayfinding Schemes Mapped to Typical Floorplates


112

Wayfinding Conventions for CCU

Ohio State University Medical Center Columbus | Ohio

M

M

M

M

Wayfinding Messages M

Map Locations

Restricted Circulation

Wayfinding Into Environment

Wayfinding for Restricted Circulation

Wayfinding Out of Environment

10.2010


113

Public Destinations within CCU

Ohio State University Medical Center Columbus | Ohio

Public Destinations Consult / Meet / Conference

Nurse / Practitioner Stations

Public Toilets

Elevators

Lounge / Waiting

Stairs

10.2010


114

Vertical Circulation Naming for CCU

West Public Elevators Color code : White

West Stair (Stair W)

Ohio State University Medical Center Columbus | Ohio

West Patient Elevators Color code : Gray

Freight Elevators Color code : Gray

Central Stair (Stair C)

West Patient Elevators Color code : Gray

East Public Elevators Color Code : Scarlet

East Stair (Stair E)

10.2010


115

Wayfinding Conventions for ACU

Ohio State University Medical Center Columbus | Ohio

Wayfinding Messages Map Locations

Restricted Circulation

Wayfinding Into Environment

Wayfinding for Restricted Circulation

Wayfinding Out of Environment

10.2010


116

Public Destinations within ACU

Ohio State University Medical Center Columbus | Ohio

Public Destinations Consult / Meet / Conference

Nurse / Practitioner Stations

Public Toilets

Elevators

Lounge / Waiting

Stairs

10.2010


117

Vertical Circulation Naming for ACU

West Stair (Stair W)

West Public Elevators

Ohio State University Medical Center Columbus | Ohio

West Patient Elevators

Freight Elevators

East Stair (Stair E)

10.2010


H O K V I S U A L C O M M U N I C AT I O N S IMAGE AND IDENTITY PLANNING INFORMATION MEDIA WAYFINDING AND ARCHITECTURAL GRAPHICS DISPLAY ENVIRONMENTS

HOK Visual Communications can strategically plan and design the appropriate vehicle to convey your message, package your information, position your image, or promote your product. Our client experience is broad in scope and international in reach. We offer deep, knowledgeable expertise in communicating about all aspects of the built environment. We seek functional, aesthetic, and economic solutions that are flexible and durable and we fully understand the business implications of good design. 2800 POST OAK BOULEVARD | SUITE 3700 | HOUSTON | TEXAS | 77056 | USA

+1 713 407 7700 | hok.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.