WAY F I N D I N G , S I G N S Y S T E M S A N D G R A P H I C D I S P L AY S R EG A R D I N G P R O J EC T O N E O H I O S TAT E U N I V E R S I T Y M E D I C A L C E N T E R D E S I G N D E V E L O P M E N T D O C U M E N TAT I O N — 10 0 % COLUMBUS | OHIO
10.2010
2
Overview
Ohio State University Medical Center Columbus | Ohio
Wayfinding, Sign Systems and Graphic Displays Summary
The following pages illustrate the known wayfinding media likely to be needed in the evolving design of this facility. Knowing that digital signage and electronic displays are specified by others, this scheme focuses on the passive messages inside the environment. The plaques and pylons that offer these messages are purposefully minimalist to align with the modernist interior design. The design intent: A modular family of signtypes deployed in a consistent material and repetitive in location. Clean, minimalist, consistent.
10.2010
3
Overview
Ohio State University Medical Center Columbus | Ohio
Wayfinding, Sign Systems and Graphic Displays Included In This Package
Exclusions
Exterior Building Signage — Includes signs attached to the building such as logo identification.
Below is a list of signage related items that are NOT addressed as part of this document:
All other site signage is understood to be designed and administered by the landscape architect.
•
Labeling of pipes, conduits, control panels, etc. Typically addressed by the specialty contractor for each system (medical gases, water pipes, etc.)
•
Illuminated emergency exit signs
•
Emergency communications devices identification and instructions
•
Fire extinguisher and hose reel identification
•
Building PA system (firefighter instructions)
•
Fire annunciation panel messages
•
Fire Department connections
Lobby identification signs (logo and/or letters)
•
Firefighter air system refill station identification and instructions
•
Lobby/level directories
•
Automated external defibrillators (AEDs)
•
Elevator lobby level informational signs
•
Enhanced graphics (murals, displays, custom artwork, banners, large wall graphics)
•
Overhead informational/directional signs
•
Exterior site signage design or coordination
•
Wall mounted directional signs
•
Shell space build out services (after the building bid documents have been issued)
•
Patient room signs
•
Temporary signage required due to phasing/scheduling
•
Department identification signs
•
Donor recognition, corner stone graphics, time capsules or other similar specialty items
•
Suite/tenant identification signs (labs, diagnostics, etc.)
•
Specialty food service or cafeteria signage
•
Base building core signage (ADA required signs, restrooms, stairs, mechanical)
•
Marketing/advertising promotional materials design (print or on-screen graphics)
•
Life safety signs (warning signs, stairwell signs, egress information)
•
Sign permits (obtaining all required permits shall the responsibility of the sign contractor)
•
Room/office identification signage
•
Amenities signs (reception, nurse’s station, cafeteria name display)
•
Informational signs (patient instructions)
•
Interior regulatory signs (bio-hazard, do not enter, radiation, x-ray, no smoking)
•
Iconic art and symbol development
•
Building identification letters and logos (emergency canopy, entrance drop-offs, etc.)
•
Entrance information signs (address, no smoking, policies)
Interior Signage Standards Program — Includes the development of a comprehensive interior signage program to address all typical interior signage room identification, informational and wayfinding signage requirements. •
10.2010
4
Quantity Estimate
Ohio State University Medical Center Columbus | Ohio
Interior and Exterior Signage Estimate
OSUMC — Sign Quantities Estimate Design Development Submittal — July 16, 2010 Revised — October 15, 2010
Interior Signage
Interior Signage (Cont.)
SIGNTYPE
DESCRIPTION
QUANTITY
SIGNTYPE
DESCRIPTION
QUANTITY
FL
Freestanding Directional Large
16
SI
Stair Identification (corridor side identification)
69
FS
Freestanding Directional
18
SS
Stair Signs (lifesafety information inside stairwell)
69
FM
Freestanding Map
10
EL
Elevator Landing Signs
136
LB
Location Beacon
60
RS
Restroom Signs
136
TM
Table Map
12
TE
Tactile Exit Signs
12
WD
Wall Mounted Directionals
245
AR
Area of Refuge
TBD
SW
Small Wall Mounted Directionals
260
TC
Two-Way Communication
29
WM
Wall Mounted Map
45
SL
Stairway Level Markers
73
FO
Floor Overview
18
OS
Occupant Load Signs
13
DD
Double Door Identification
355
NE
Tactile No Exit Signs
11
OD
Overhead Directional
145
DE
Delayed Egress Door Signs
8
LO
Large Overhead Directional
67
PD
Powered Door Leaf Signs
34
PA
Perpendicular Announcer
172
MS
Movable Stanchion
19
Building Signage / Exterior Signage
HR
Horizontal Rule Letters
28
PP
Perpendicular Pictogram
131
CP
Corner Mounted Pictogram
61
CD
Corner Mounted Directional
DS
Door Mounted Safety Information
RN
DESCRIPTION
QUANTITY
PL
Primary Logo Identification Sign (Illuminated — South Facade)
1
PW
Primary Logo Identification Sign and Building Name (Illuminated — West Facade) 1
35
BN
Building Name Identification Sign (Illuminated — South Facade)
1
592
EE
Emergency Identification Sign (Illuminated — North Facade)
1
Room Number (only—closets, mechanical, etc.)
370
TC
Street Level Building Name Identification Sign (Illuminated)
2
RI / RRI*
Room Insert (room number with room function description insert)
670
SA
Street Address Numbers (Non-Illuminated)
4
PR
Patient Room Identification
300
VG
Graphics at Building Entry (Non-Illuminated)
4
IH**
Insert Holders
50
IL**
Large Insert Holders
50
*Use Retrofitted Room Sign (RRI) as an option in place of RI; added after Oct 15 Design Review
**Added after Oct 15 Design Review
10.2010
5
Introductory Notes to CD Development
Ohio State University Medical Center Columbus | Ohio
Finalization of DD Phase Design Review Oct. 2010
Cost
Epidemiology
It is the desire of the design team to retain the use of 3Form Chroma ® for larger, free standing signage,
It is compatible to use 3M Phenolic Cleaner on 3F Chroma ® surfaces. A 7 Day Full Immersion Test was
while smaller, code required signage will use a similar but less costly material as substitute — 3Form
performed and no compatibility problems were found. However, minor staining of the 3F Chroma ® maybe
EcoResin. Furthermore, additional savings are realized in the reduction of material use with revised
visible due to the cleaner’s natural amber hue, which can be easily removed by renewing 3F Chroma ®
specifications of thinner gauges throughout the document. We feel that by making the aforementioned
surface. It is important to note that the 7 Day Full Immersion Test is a fairly substantial compatibility test
changes will reduce costs dramatically without eroding the overall aesthetics of the wayfinding program.
and sometimes will show results that will not be encountered under normal circumstances. Other hospital
However, if further cost cutting is necessary, three alternate material sets are proposed on page 17 with
grade disinfectants tested for compatibility with 3F Chroma ® include: Precise, Dispatch, and Virex II
the intention of gradually lowering cost per sign to meet targeted budget allowance. It is a reminder that excessive cost cutting can negatively impact the quality of the program.
For detailed information, contact 3Form representatives below: Donyce Rich — donyce.rich@3-form.com
Operational Usability
Charles Moore — charles.moore@3-form.com
• Room Insert signs (RRI) revised to match existing design and usability standards • Inserts sizes standardized to quarter page 8.5" x 11" letter size on sign type RRI. • Patient advisories window added to sign type RRI. • See notes on extension of sign type WD and SW on page 36. Color Coding It has been decided to eliminate the use of color bar in the wayfinding system of ProjectOne due to the fact a color coding strategy has not been successfully implemented by OSU. It is a concern that the addition of colors as a visual element on signs may potentially confuse a viewer. Moreover, assigning a unique and specific color per campus building presents an obstacle due to the limited number of identifiable colors. In response, the building name will be incorporated in the header display on large signs and the proposed
Additional Sign Types Sign type WM (Wall Mounted Map) can be used in place of FM (Free Standing Map) in situations where available floor spaces are limited or when an optimal location can not be located. Use wall mounted maps at next logical location or the nearest adjacent wall. Simple insert holders in two sizes as requested by OSU. See sign type IH (letter size) and IL (tabloid size). Typography OSU brand font — Whitney — is used for all wayfinding materials pertaining to ProjectOne. Otherwise, follow existing university typographic rules for all other buildings.
usage of building specific prefix on room signs.
Other Notes
ADA Standards
Unused sign types are purposefully preserved in the document for future references.
Sign types are drawn in compliance with ADA and other safety codes as of date of original issue. Reconfirm and update drawings to ADA standards prior to fabrication. Contact Scott Lisner, University ADA Coordinator for information.
Certain sign types in the wayfinding program are offered but may not be applicable to ProjectOne.
Set screws in construction are to be always omitted when fraction from tight tolerance of routed parts is adequate to secure panels in place. Providing functional prototype for approval prior to fabrication.
10.2010
6
Wayfinding Experience
Ohio State University Medical Center Columbus | Ohio
General Overview of Scale and Application
Exterior Building Mounted Landmark architecture, sign(s) on building
Interior Circulation
Lobby pylon wayfinding, exclusive material
Floor Arrival Departments and Rooms Dimensional logo and announcer behind main reception desk; Lobby entry experience
Public/Staff Restricted Areas
Restrooms, staff stations, warning icons and all other basic egress signage
Light box as visual totem offers directory/mapping messages; Lobby portals into ground floor functions
Dimensionally cut out names of department, function rooms
Overhead directional and entry announcers on hallways
Destination Legends
Overhead directional
Perpendicular wall mounted signage
Elevator lobby; elevator exchange; level indicators elevator jam tags
Mapping and directory (Freestanding optional)
Signs on building, graphics at entry
6 5
BUILDING NAME
4 INFORMATION
2 1 G
Basic egress, restrooms, and utility rooms signage
T H E JA M E S
T H E JA M E S
In Building Destination
T H E JA M E S
T H E JA M E S
In Building Destination
In Building Destination In Building Destination
In Building Destination
In Building Destination
In Building Destination
In Building Destination
In Building Destination
In Building Destination
Exam Room
Dimensional names of function rooms. Warning/hazard icons
T H E JA M E S
T H E JA M E S
Cut out letters
10.2010
7
Typography
Ohio State University Medical Center Columbus | Ohio
Brand Fonts and Usage
Whitney Font Family —Primary Narrative Typography
Whitney Medium
Whitney Light
ABCDEFG HIJ K L M N O P Q R ST UV W X Y Z abcdefghijklmnopqr stuv w x y z
ABCDEFGHIJK L MNOPQR ST UV W X YZ abcdefghijklmnopqrstuv w x yz
12 3 4 5 6789 0
123 4567890
Whitney Book
Whitney Semi Bold (Type Set for Extra Legibility)
ABCDEFGHIJK L MNOPQR ST UV W X Y Z abcdefghijklmnopqrstuv w x y z
ABCDE FG H IJ K L M NO P Q R STU V W X Y Z abcdef ghijklmnopqr stuv w x y z
12 3 4567890
12 3 4 5 67890
10.2010
8
Message Coding
Ohio State University Medical Center Columbus | Ohio
Visual Way-Training
We will use visual coding of signs to overcome visual clutter. We will see messages presented with a consistent color coding. Requires consistent look of message vehicles and message layouts — it is the coloration of codes.
Gray on White Messages to Public
Black on Yellow Caution Attention Messages
White on Gray Messages for Practitioners
Black on Orange Hazard Warning Messages
Red on White Life Safety Messages
Black on Green Equipment Requirement Messages
White on Red Life Safety Messages
Black on Blue Equipment Availability Messages
Modular size and consistent material will support a consistency in the visual vocabulary 10.2010
9
Pictograms
Ohio State University Medical Center Columbus | Ohio
References
RESTROOMS
Men
Elevator
Women
Patient elevator
Restroom
Accessibility
Automated elevator
Freight elevator
Stairs
Stairs up
Stairs down
EGRESS / SAFETY
Fire exit
Fire extinguisher
Fire alarm
No littering
No animals
Defibrillator
Area of Refuge
Exit
PROHIBITORY
No smoking
No phone
No food
No music
No pictures
BACK DIRECTIONAL
10.2010
10
Pictograms
Ohio State University Medical Center Columbus | Ohio
References
AMENITIES
Drinks
Dining
Gift
Information
Telephone
Litter disposal
Surgery
Waiting area
Diagnostic imaging
Library
Water fountain
Excercise room
Mail box
Shower room
Cashier
Locker
MISC.
Pharmacy
Physical therapy
Emergency dept.
10.2010
11
Pictograms
Ohio State University Medical Center Columbus | Ohio
References
HAZARDS
Coded in orange, Position in diamond
FIre hazard
Biohazard
Poisons
Oxidizer
Radioactivity
Generic caution
High voltage
Laser usage
Flammable
Explosive
Gloves required
Eye protection required
Respirator required
Protective coat required
Low volume required
Respirator
Eye protection
Eye wash
Body shower
Harmful to foodstuffs
Corrosive
NFPA 704 HAZ
CAUTIONS
Coded in yellow, Position in triangle
Caution footing
Magnets
REQUIREMENTS
Coded in green, Position in circle
AVAILABILITY
Coded in blue, Position in circle
UV disinfectant
10.2010
12
General Sizes and Proportions
Ohio State University Medical Center Columbus | Ohio
Freestanding and Other Large Scale Signage
Proportional Shapes Visual consistency of the display and freestanding members of the signage family is achieved using a standard building block of an 8” x 8” square. The standard unit was applied incrementally to both horizontal and vertical measurements as necessary to increase sign to a viable size. Deviations are allowed when proportional sizes are not permissible due to the manufacturing process or existing graphical standards.
8”
11X
8”
2X
2.5X
2
Level Two Name of Building
2X
2
Level Two Name of Building
X
2.5X
2
2 6X
12X
Laboratory Specialty Clinic Education Center
Admissions Outpatient Clinic Solid Tumor, Hemo Oncology
Elevators
Level 19 Level 18 Level 17 Level 16 Level 15 Level 14
Information Lobby
Emergency
Admission Outpatient Clinic
2
Pharmacy
2
5X
Pharmacy Diagnostic Imaging
Admission Office
Admission Office
Infusion Dept.
Infusion Dept.
Lobby
3X
Parking
X
X
Level Two Building Name
Emergency
Diagnostic Imaging
Restrooms
Laboratory Education Center
3X
Level Two Building Name
Level Two Name of Building
Level Two Name of Building
Level 19 Level 18 Level 17 Level 16 Level 15 Level 14
Information Lobby
3X
Rooms P808-P813
Rooms P808-P813
Rooms P808-P813
Rooms P801-P804 P815-P820
Emergency Parking Garage
Radiology Acute Assessment Admission 11X
X
Emergency
Radiology
5X
Rooms P808-P813
3X 0.5X
Radiology
0.5X
Hemo Oncology
Elevators
Legend Key
Parking
Destination A Destination B Destination C Destination D
Destination A Destination B Destination C Destination D
Destination A Destination B Destination C Destination D
Destination A Destination B Destination C Destination D
Destination A Destination B Destination C Destination D
Destination A Destination B
Destination A Destination B Destination C Destination D
Destination A Destination B Destination C Destination D
Destination A Destination B
Café Gift Shop
Elevators North and West
10.2010
13
General Sizes and Proportions
Ohio State University Medical Center Columbus | Ohio
Code Required and Wall Mounted Signs
Proportional Shapes Visual consistency of wall mounted and code required members of the signage family is achieved using a standard building block of a 1.75” x 1.75” square. The standard unit was applied incrementally to both horizontal and vertical measurements as necessary to increase sign to a viable size. Small deviations are allowed when proportional sizes are not permissible due to the manufacturing process or existing graphical standards.
1.75” 3.5 X
3.5 X
3.5 X
3X
3X
3X
3.5 X
4X
4X
5X
1.75”
Stair East West Stair C X
P1245
P1245 3X
Examination Room Descriptions Here
12300 4X
Critical Care Unit Patient’s Name Doctor’s Name (AM) Doctor’s Name (PM) Nurses’ Names
4X
In the event of emergency, this phone will provide direct contact to security and emergency personnel.
Area of Refuge
In Fire Emergency, Do Not Use Elevator. Use Exit Stairs. Evacuation Map
5X
5X
6X
5X
9X
7X
15
Re-Entry on L5-10
Emergency Phone
Down To 1ST Floor For Exit Discharge
EXIT
MEN
EXIT
EXIT
5.5” x 8.5” evacuation map
10.2010
14
Neutral Color Scheme
Ohio State University Medical Center Columbus | Ohio
Color Usage in Signage Family Overall Color Scheme
Message and Accent Colors
with the available ambient light and the ambient color of the environment, resulting in better visual integration and
are chosen for their vibrancy (ability to draw viewers’ attention), and also for their attractiveness/visual compatibility when
overall color temperature. Expect interesting dynamic visual shifts in daytime and nightime appearance.
used along side with the neutral color scheme of the signs. Name of colors are pronounceable for verbal referencing.
The base color of the sign family is the translucent, milky white, natural finish of the Chroma material. Chroma “blends”
Additional colors are to be used to reinforce the contents of the message when presented as part the signage system. Colors
Dark Grey For legibility and contrast; paint or as Chroma material color
S
E
C
Orange: In the ranges of PMS 151 to distance away from yellow
Light Grey O
N
D
For visual contrast; paint or as Chroma material color
Teal: In the ranges of PMS 312, between the hues of green and blue
Black: Process black
A R
Y
White C
For visual contrast; paint or silk screening
O
L O R
S
OSU Red Brand recognition and visual contrast; paint or as Chroma material color
Neutral Colors
Original Material color, Translucency, Neutral Off-White
Yellow: In the ranges of PMS 108 with a slight magenta content
Green: In the ranges of PMS 368
Blue: In the ranges of PMS 3005
10.2010
15
Materials
Ohio State University Medical Center Columbus | Ohio
Introduction to Materials on Freestanding Signs A
Overview of Material Selection & Specification for
B
Large & Free Standing Sign Types A
3form Chroma
®
Clear Acrylic
Optically clear acrylic without color tints or texture. Diamond polished at all exposed edges. Use matte paint on first surface only, leave edges unpainted when D
Color: White Finish: Renewable Matte
applying colors.
Bold, solid, translucent surface with the ability to saturate with C
custom colors. The translucent quality of Chroma® helps blend the ambient light and takes on complimentary appearance to its
Vinyl
Cut out vinyls adhered to first surface of frosted panels.
surroundings. Chroma® contains 40% pre-consumer recycled
Matte finish.
material and is more ecological than other resins or polycarbonates. It can be resurfaced and re-colored during maintenance therefore allowing for longer life span of signage. Exposed edges are finished
D
and blemish-free.
Retainer Frame
Other ideal attributes include:
Use to hide fasteners or other hardware from view.
Durability — solid and sturdy for a variety of horizontal or vertical applications
Frame also serves as a structural support element and
Formable — can be shaped to accommodate radius curves
D
covers at least three sides of the sign structure. Matte,
Renewable — surface can be renewed after years of use Structural — thick and stable for engineered load bearing applications Translucent — amazing clarity for unrivaled light transmission
platform for attachment of Chroma® panels. Frame
B
brushed metal finish.
B
For additional information, visit http://www.3-form.com/materials-chroma.php C B B
10.2010
16
Materials
Ohio State University Medical Center Columbus | Ohio
Introduction to Materials on Wall Mounted Signs Overview of Material Selection & Specification for
B
A
Code Required Sign Types
D
D
Backer
Frosted acrylic panel with similar look and feel of the Ecoresin®. Diamond polish/ smooth finish all exposed edges. Adhere directly to the second surface of
A
3Form Varia Ecoresin
Ecoresin®. Use 1/8” thickness for structural rigidity.
®
Style: White Out FF: Supermatte BF: Supermatte E
Frosted visually and texturally. All exposed edges to be finished with
E
consistent texture as the main surfaces. Info: http://www.3-form.com/materials-varia_ecoresin.php
B
Spacer
Frosted acrylic panel for placement of double-sided tape or adhesive when C
Clear Engraving Stock / Photopolymer
mounting on wall. Optional to use opaque panel to block visibility of mounting hardware from showing through from the front of sign. Spacer panel lifts sign off the wall and is hidden from view.
Optically clear acrylic without color tints or texture. Tactile and braille created on this layer. Adhere to first surface of Ecoresin®.
C
Clear Acrylic
Ex Deamin sc at rip ion tio R ns oo He m re
Optically clear acrylic without color tints or texture. Diamond polished at all exposed edges. Use matte paint on first surface when applying colors.
D
Paint on first surface only
Paper Insert
Conventional, full-color laser printing.
A
D
Paper stock of 90lbs. and up.
Clear sides and edges
10.2010
17
Alternate Material Sets
Ohio State University Medical Center Columbus | Ohio
Material Substitutions OSUMC Wayfinding System Material Sets
Preferred/Proposed Material Set
Three suggested material sets are acceptable options in reducing costly material usage. Alternate material sets are to mimic the appearance of Chroma with substitute proprietary or non-proprietary materials to acheive visual continuity throughout sign family.
Alternate Material Set 1
Alternate Material Set 2
Alternate Material Set 3
Freestanding Sign Types (high visibility and high traffic locations; large in mass but few in numbers)
Polycarbonate (Level indicator)
Polycarbonate
Chroma
Chroma
®
View
Polycarbonate
Polycarbonate Frosted Polycarbonate
®
View
View
View
Chroma ® or Ecoresin ® Cost of Chroma > Cost of Ecoresin
Expensive
Inexpensive 1/4” thick Ecoresin ® with Patina finish and translucency to match look of Chroma
1/2” Chroma ®
Code Required Sign Types (appear throughout building; small in mass but numerous in numbers) View
View
1/4” thick Frosted Polycarbonate
View
1/4” thick Frosted Polycarbonate
View
Clear acrylic (window for insert)
Clear acrylic
Clear acrylic
Clear acrylic
Clear photopolymer for tactile and braille
Clear photopolymer for tactile and braille
Clear photopolymer for tactile and braille
Clear photopolymer for tactile and braille
10.2010
18
Internal Illumination
Ohio State University Medical Center Columbus | Ohio
Subtle Visual Accent on Freestanding Signage Accent Illumination
Location of LED Diodes
For installation on large, freestanding signage only. A subtle light
The light source is directed vertically from bottom to top
source can be placed at the bottom of the sign causing the sign to
in a gradual fade as brightness dims toward the top of
give off an attractive “glow”. The translucency of the Chroma®
sign. LED diodes and supporting components are
material will naturally carry light through the body of the sign,
located within the metallic base of the sign which will be
therefore, low-intensity light source such as LED is acceptable.
expansion bolted to ground. Intensity of the LED to
Diffuse light source and tune color temperature of LED (using
carry through at least half of height of sign.
tinted films) to best compliment interior lighting.
2
Level Two Name of Building
Information Lobby
2
Level Two Name of Building
2
2
Level Two Name of Building
Laboratory Education Center
Other LED illuminated surfaces include map graphics
Admission Outpatient Clinic
Information Lobby
Elevators
Elevators’ names here
Laboratory Education Center
Admission Outpatient Clinic
2
Level Two Name of Building
Emergency
Emergency
Emergency
Emergency
Infusion Department
Infusion Department
Infusion Department
Infusion Department
CTU/ Pharmacy
CTU/ Pharmacy
CTU/ Pharmacy
CTU/ Pharmacy
Outpatient Clinic
Outpatient Clinic
Outpatient Clinic
Outpatient Clinic
North and West
19 19 Name 19 19
Name 19 19
Name 19 19
Name
Pictogram One
Elevators
Direction of light
Destinations
Pictogram Four
Pictogram Two
Pictogram Five
Pictogram Two
Pictogram Five
To reach Building Security: 123-584-9648 Medical Center Information: 123-584-9648 Special Assistance: 123-584-9648
Name Name
Location of LED Base Open
10.2010
19
Header and Legend Graphics
Ohio State University Medical Center Columbus | Ohio
Details and Descriptions
Double sided sign
2
.25”
2
Large Numeral Level Indicator Clear acrylic panel .25” in thickness cut into shape. Adhere to surface of sign. Silk screen front surface with PMS 421 in matte, eggshell finish. Leave sides unpainted. Diamond polish all exposed edges. Level Indicator Clear acrylic panel .25” in thickness cut into shape. Adhere to surface of sign. Silk screen surface with red* in matte, eggshell finish. Leave sides unpainted. Diamond polish all exposed edges.
Level Two The James Cancer Center
Building Name Display Confirm building name with owner prior to fabrication Clear acrylic panel .25” in thickness cut into shape. Adhere to surface of sign. Silk screen front surface with PMS 425 in matte, eggshell finish. Leave sides unpainted. Diamond polish all exposed edges.
Chroma ®
Directional Arrow Clear acrylic panel .25” in thickness cut into shape. Adhere to surface of sign. Silk screen front surface with red* in matte, eggshell finish. Leave sides unpainted. Diamond polish all exposed edges.
Admissions
Chroma ®
Outpatient Clinic
Raised acrylic surfaces
Raised acrylic surfaces
Leave sides unpainted & clear
Painted surface
Chroma ® Legend 3M vinyl to match dark gray PMS 425. Directional Arrow
Laboratory
Retainer Frame
2 dimensional vinyl letters *Obtain OSU brand PMS color in red
1
Typical Header Graphics and Legend — Front View
2
Side View
3
Isometric
H
Scale NTS
H
Scale NTS
H
Scale NTS
10.2010
20
Header Graphics Layouts and Typopgrahic Details Header Graphics — Level Indicators and Building Name Visual consistency of the display and freestanding members of the signage family is
1.75”
achieved using a standard building block of an 8” x 8” square. The standard unit was applied incrementally to both horizontal and vertical measurements as necessary to increase sign to a viable size. Small deviations are allowed when standardized sizes are not permissible due to the manufacturing process.
11.625”
2”
1.5”
G
Ground Level James Cancer Center
Ohio State University Medical Center Columbus | Ohio
Large Numeral Level Indicator Font: Whitney Book Italic Size: Approx. 1175 pts.
Level Indicator Font: Whitney Semibold Size: Approx. 100 pts. Building Name Display Font: Whitney Book Italic Size: Approx. 100 pts.
1”
1
Sample Layouts
LI
Scale 1:4
10.2010
21
Header Graphics
Ohio State University Medical Center Columbus | Ohio
Sample Layouts
G
1 2 4 5 6 9 11
Ground Level Name of Building
Ground
Level One Name of Building
Level One
Level Two Name of Building
Level Two
Level Four Name of Building
Level Five Name of Building
Level Five
Level Four
Level Six Name of Building
Level Six
Ground Eleven Name of Building
Level Nine Name of Building
Level Nine
Level Eleven
12 13 14 15 16 17 18 19 Level Twelve Name of Building
Level Twelve
1
Sample Layouts
LI
Scale 1:15
Level Thirteen Name of Building
Level Thirteen
Level Fourteen Name of Building
Level Fourteen
Level Fifteen Name of Building
Level Fifthteen
Level Sixteen Name of Building
Level Sixteen
Level Seventeen Name of Building
Level Seventeen
Level Eighteen Name of Building
Level Eighteen
Level Nineteen Name of Building
Level Nineteen
Note: Levels 3, 7, 8 are omitted from building 10.2010
22
Interior Signage
Ohio State University Medical Center Columbus | Ohio
Sign Family Overview
Note on Overhead Sign Types Adjust length of Vertical Support in
Emergency
AMTU/Apherisis
proportion to available ceiling height.
Overhead Directional
[OD]
2
2
2
2
Level Two Name of Building
Level Two Name of Building
Note on Wall Mounted Signs Mounting height is flexible and is ultimately determined by available wall space.
Emergency
Level 19 Level 18 Level 17 Level 16 Level 15 Level 14
Information Lobby
Laboratory Education Center
2
Admission Outpatient Clinic
Level Two Name of Building
Destinations Emergency
Emergency
Emergency
Emergency
Infusion Deptartment
Infusion Deptartment
Infusion Deptartment
Infusion Deptartment
CTU/ Pharmacy
CTU/ Pharmacy
CTU/ Pharmacy
CTU/ Pharmacy
Outpatient Clinic
Outpatient Clinic
Outpatient Clinic
Outpatient Clinic
19 19 Name 19 19
Name 19 19
Name 19 19
Name
Pictogram One
Pictogram Four
Pictogram Two
Pictogram Five
Pictogram Two
Pictogram Five
To reach Building Security: 123-584-9648 Medical Center Information: 123-584-9648 Special Assistance: 123-584-9648
Name Name
Elevators
Level 19 Level 18 Level 17 Level 16 Level 15 Level 14
Information Lobby
Laboratory Specialty Clinic Education Center
Admissions Outpatient Clinic
2
Level Two Name of Building
Level Two Name of Building
Level Two Name of Building
2
Level Two Building Name
Emergency
Pharmacy
Pharmacy
Diagnostic Imaging
Diagnostic Imaging
Admission Office
Admission Office
Infusion Dept.
Infusion Dept.
Lobby
Parking
Elevators
Legend Key
Parking
Destination A Destination B Destination C Destination D
Destination A Destination B Destination C Destination D
Destination A Destination B Destination C Destination D
Destination A Destination B Destination C Destination D
Destination A Destination B Destination C Destination D
Destination A Destination B
Destination A Destination B Destination C Destination D
Destination A Destination B Destination C Destination D
Destination A Destination B
CafĂŠ Gift Shop Restrooms Waiting Rooms
Solid Tumor, Hemo Oncology
Elevators
North and West
Note on Height Empty space at the lower portion can be reduced to shorten height of sign. Additional graphical adjustments may be necessary to ensure an optimal presentation.
Table Map
[TM]
Location Beacons
Small Freestanding Directional
Large Freestanding Directional
[LB]
[FS]
[FL]
Freestanding Map
[FM]
Wall Mounted Directional
Small Wall Mounted Directional
[WD]
[SD]
Scale 1:30
10.2010
23
Interior Signage
Ohio State University Medical Center Columbus | Ohio
Sign Family Overview
Perpendicular Pictogram
[PP]
West Stair C
WOMEN
EXIT EXIT
Stair East
15
P12345
P12345
P12345 Hemo Oncology Dr. Mallisu Dr. York
npo
Critical Care Unit Patient’s Name Doctor’s Name (AM) Doctor’s Name (PM) Nurses’ Names
Room Available
Re-Entry on L5-10 Down to 1 ST Floor For Exit Discharge
Restroom Sign
Tactile Exit Sign
[RR]
[TE]
Stairway Identification
[SI]
Stair Sign
Room Number
[SS]
[RN]
Room Number With Insert
[RI]
Patient Room Sign
[RP]
10.2010
24
Interior Signage
Ohio State University Medical Center Columbus | Ohio
Sign Family Overview
Overhead Pictogram Sign
Surgery — Descriptions
Intravenous Radiation
PACU — Descriptions
Restrooms Vending Machines Family Waiting Room
Peri-Op — Descriptions
Level Four
OutpatientClinic — Solid Tumor
CTU
OutpatientClinic — Hemo Oncology
Pharmacy
Restrooms Vending Machines Family Waiting Room
Infusion Department Level Two
In Fire Emergency, Do Not Use Elevator. Use Exit Stairs. Evacuation Map
Café Cafeteria Pharmacy
Pharmacy Lobby AMTU/ Apherisis
Restrooms Vending Machines Family Waiting Room
Restrooms Vending Machines Family Waiting Room
Conference Education Admissions Lobby
Corner Mounted Pictogram
Elevator Landing Sign
Floor Overview
[CP]
[EL]
[FO]
Conference Rooms
4 2
1
Level One
Restrooms Vending Machines Family Waiting Room
Ground
G
10.2010
25
Interior Signage
Ohio State University Medical Center Columbus | Ohio
Sign Family Overview
Dimensional Letters
Emergency Unit Level 8
Emergency Instructions • Rinse the wound thoroughly with water to clean out dirt and debris. • Then wash the wound with a mild soap and rinse thoroughly. (For minor wounds, it isn't necessary to use an antiseptic solution to prevent infection, and some can cause allergic skin reactions.) • Cover the wound with a sterile adhesive bandage or sterile gauze and adhesive tape. • Examine the wound daily. If the bandage gets wet, remove it and apply a new one. After the wound forms a scab, a bandage is no longer necessary. • Call your child's doctor if the wound is red, swollen, tender, warm, or draining pus.
Evacuation Plan
You Are Here
Restricted Zone
High Voltage Zone ADDITIONAL INFORMATION
PULL
7
4
Radiation
Spontaneously Combustible
CONTENTS & ACTIVITY
PULL
First Aid
AED
Gloves Required
Eye Protection Required
Eye Wash Available
Chemical Shower Available
Authorized Personnel Only Do Not Enter
Movable Stanchion
[MS]
Fire Safety Station
Fire Safety Station
Life Safety Station
Door Mounted Safety Information
[DS]
10.2010
Interior Sign Family Descriptions and Design of Individual Sign Types
27
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Large Freestanding Directional [FL]
Fastener
Top panel
20”
4.5”
2
Numeral level indicator Level indicator
Level Two Name of Building
See page on Header and Legend Graphics
La bo S p r a to ec r E d ialt y y uc a t i Cl i n on ic Ce n te r Ad m O u is si tp a o n So lid ti e Tu m Ele or, Hemo nt C va Oncolo lin tor gy ic s
Information Lobby
Laboratory Specialty Clinic Education Center
78”
96” Admissions Outpatient Clinic Solid Tumor, Hemo Oncology
Elevators
Expansion bolts secure to ground
12” 19” open
6.5”
Inf o Lo r m at bb i y on
.5”
Building name display
Stainless steel retainer frame
Chroma ®
Exposed edges of Chroma ® panel; sand and smooth to match finish on face Elevated stainless steel base; non-glare with satin finish
1”
1
Large Freestanding Directional
2
Side View
3
Isometric
FL
Scale 1:25
FL
Scale 1:25
FL
Scale NTS
10.2010
28
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Freestanding Directional [FS] Fastener
Top panel
16”
Numeral level indicator
4.5”
2
Level indicator
See page on Header and Legend Graphics
Level Two Name of Building
Stainless steel retainer frame
Information Lobby
78”
Building name display
Laboratory Education Center 96”
Chroma ®
Admission Outpatient Clinic Elevators
Exposed edges of Chroma ® panel; sand and smooth to match finish on face
North and West
Expansion bolts secure to ground
12” 19” 6.5”
Elevated stainless steel base; non-glare with satin finish
.5” 1”
1
Freestanding Directional
2
Side View
3
Isometric
FS
Scale 1:25
FS
Scale 1:25
FS
Scale NTS
10.2010
29
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Freestanding Map [FM] 2.5”
20”
15”
2
6.5” 20”
2
.75”
2.5”
.25”
1.75”
Note: This signtype is intended to be a single-sided sign. The thickness of width can be adjusted to accomodate for a double sided modification.
See page on Header and Legend Graphics
Level Two Name of Building
Level Two Name of Building
5”
Level 19 Level 18 Level 17 Level 16 Level 15 Level 14 Level 19 Level 18 Level 17 Level 16 Level 15 Level 14
Level 19 Level 18 Level 17 Level 16 Level 15 Level 14 Level 19 Level 18 Level 17 Level 16 Level 15 Level 14
View
View
Retainer frame 78”
Opening for map; duratrans printed graphics and backlit
Legend Key Destination A Destination B Destination C Destination D
Destination A Destination B Destination C Destination D
Destination A Destination B Destination C Destination D
Destination A Destination B Destination C Destination D
Destination A Destination B Destination C Destination D
Destination A Destination B
Destination A Destination B Destination C Destination D
Destination A Destination B Destination C Destination D
96”
Destination A Destination B
58.75”
Legend Key
12”
Destination A Destination B Destination C Destination D
Destination A Destination B Destination C Destination D
Destination A Destination B Destination C Destination D
Destination A Destination B Destination C Destination D
Destination A Destination B Destination C Destination D
Destination A Destination B
Destination A Destination B Destination C Destination D
Destination A Destination B Destination C Destination D
Destination A Destination B
Chroma ®
19”
Chroma ®
6.5” .5” 1”
1 FM
Freestanding Map Scale 1:25
2
Side View
3
FM
Scale 1:25
FM
Front Details Scale 1:15
4 FM
Side Details Scale 1:8
10.2010
30
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Freestanding Map [FM] Fastener Detachable panel for access to interior electronic components
Top panel
Map on duratrans output
Numeral level indicator Level indicator
Lev el Lev 19 el Lev 18 el Lev 17 el Lev 16 el Lev 15 el 14 Lev el Lev 19 el Lev 18 el Lev 17 el Lev 16 el Lev 15 el 14
LED light source Lev el Lev 19 el Lev 18 el Lev 17 el Lev 16 el Lev 15 el 14 Lev el Lev 19 el Lev 18 el Lev 17 el Lev 16 el Lev 15 el 14
Le
ge
Des Destinat Destination A Destination B tin ion atio C nD Des Destinat Destination A Destination B tin ion atio C nD Des Destinat Destination A Destination B tin ion atio C nD Des Destinat Destination A Destination B tin ion atio C nD
nd
Ke
Des Destinat Destination A Destination B tin ion atio C nD Des Destinat Destination A Destination B tin ion atio C nD Des Destinat Destination A Destination B tin ion atio C nD Des Destinat Destination A Destination B tin ion atio C nD
Le
ge
Des Destinat Destination A Destination B tin ion atio C nD
Diffuser panel
Des Destinat Destination A Destination B tin ion atio C nD Des Destinat Destination A Destination B tin ion atio C nD
Inset
y Des Destinat Destination A Destination B tin ion atio C nD Des Destinat tin ion atio A nB
Des Destinat Destination A Destination B tin ion atio C nD
Des Destinat tin ion atio A nB
Des Destinat tin ion atio A nB
nd
Ke
Des Destinat Destination A Destination B tin ion atio C nD Des Destinat Destination A Destination B tin ion atio C nD Des Destinat Destination A Destination B tin ion atio C nD Des Destinat Destination A Destination B tin ion atio C nD
Building name display
y Des Destinat Destination A Destination B tin ion atio C nD Des Destinat tin ion atio A nB
Des Destinat tin ion atio A nB
Stainless steel retainer frame
Des Destinat tin ion atio A nB
Chroma ÂŽ
Exposed edges of Chroma ÂŽ panel; sand and smooth to match finish on face Expansion bolts secure to ground
Protective clear glass or acrylic panel
1
Isometric
2
Isometric
FM
Scale 1:25
FM
Scale 1:15
Elevated stainless steel base; non-glare with satin finish
10.2010
31
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Location Beacon [LB] Fastener
Top plate
8”
Numeral level indicator
4.5”
2
Level indicator
Building name display
Level Two
Name of Building
Stainless steel retainer frame
78” 96”
Chroma ®
Exposed edges of Chroma ® panel; sand and smooth to match finish on face
Expansion bolts secure to ground
12” 19” 6.5”
Elevated stainless steel base; non-glare with satin finish
.5” 1”
1
Location Beacon
2
Side View
3
Isometric
LB
Scale 1:25
LB
Scale 1:25
LB
Scale NTS
10.2010
32
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Table Map [TM]
Duratrans map graphics on elevated platform; backlit with neutral temperature LED light Side column space for level indicator and supporting graphics
60”
30”
2
Level Two Name of Building
Elevated stainless steel base; non-glare with satin finish
Destinations Emergency
Emergency
Emergency
Emergency
Infusion Deptartment
Infusion Deptartment
Infusion Deptartment
Infusion Deptartment
CTU/ Pharmacy
CTU/ Pharmacy
CTU/ Pharmacy
CTU/ Pharmacy
Outpatient Clinic
Outpatient Clinic
Outpatient Clinic
Outpatient Clinic
19 19 Name 19 19
Name 19 19
Name 19 19
Name
Pictogram One
Pictogram Four
Pictogram Two
Pictogram Five
Pictogram Two
Pictogram Five
Name
To reach Building Security: 123-584-9648
Name
Medical Center Information: 123-584-9648 Special Assistance: 123-584-9648
55” 5”
Expansion bolts secure to ground
Stainless steel Retainer Tray; non-glare with satin finish
Chroma®
12”
Open
Open
(See separate RTKL technology package for monitor based maps)
6.5” .5” 1”
6.5”
1
Table Map
2
TM
Scale 1:25
TM
Right Side View Scale 1:25
3
Isometric
TM
Scale NTS
10.2010
33
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Table Map [TM] Main Map Graphics Backlit with LED
Side Margin for support information to adjacent map graphics
2
Backlit map Dimensional “You Are Here” indicator
Chroma ® 1/2” inset
Level number and other building information
Level Two Name of Building
Clear acrylic header with painted surfaces. See section on header graphics
Destinations Emergency
Emergency
Emergency
Emergency
Infusion Deptartment
Infusion Deptartment
Infusion Deptartment
Infusion Deptartment
CTU/ Pharmacy
CTU/ Pharmacy
CTU/ Pharmacy
CTU/ Pharmacy
Outpatient Clinic
Outpatient Clinic
Outpatient Clinic
Outpatient Clinic
Chroma ® 19 19 Name 19 19
Name 19 19
Name 19 19
Name
Pictogram One
Pictogram Four
Pictogram Two
Pictogram Five
Pictogram Two
Pictogram Five
To reach Building Security: 123-584-9648 Medical Center Information: 123-584-9648 Special Assistance: 123-584-9648
1/2” inset
Name Name
Overview Building Map Indications of all levels in building and the location of viewer within building
Open
Legend, Pictograms, and Notes
1 TM
Sample Map Layout Scale 1:10
2 TM
Prespective View Scale NTS
10.2010
34
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Table Map [TM]
60”
2
44.625”
Top Protective glass
15”
24”
Level Two Name of Building
35.75”
Header graphics
Destinations Emergency
Emergency
Emergency
Emergency
Infusion Deptartment
Infusion Deptartment
Infusion Deptartment
Infusion Deptartment
CTU/ Pharmacy
CTU/ Pharmacy
CTU/ Pharmacy
CTU/ Pharmacy
Outpatient Clinic
Outpatient Clinic
Outpatient Clinic
Outpatient Clinic
19 19 Name 19 19 19
Name 19 19
Name
Pictogram One
Pictogram Four
Pictogram Two
Pictogram Five
Pictogram Two
Pictogram Five
To reach Building Security: 123-584-9648 Medical Center Information: 123-584-9648 Special Assistance: 123-584-9648
Duratrans map graphics
19
Name
11.5”
Name Name
Diffuser panel Uniform LED light source* floods entire surface.
59.75”
Edge of retainer tray; 1/8 thick stainless steel
1 TM
Measurements Scale 1:10
*CeeLite LEC ultra thin, flexible illuminated panels recommended
2 TM
Mapping Display Composite Scale NTS
10.2010
35
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Wall Mounted Directional [WD] Retainer Tray. Aluminum construction for structural rigidty; in non-glare, satin finish.
.25” 24”
16”
2
Level Two Name of Building 4” Full Panel
Emergency
Header — Chroma ® P: Chroma White Out FF: Renewable Matte
1”
Reverse silk screen printed surface on Chroma ®. Background color in OSU red* in matte eggshell finish. Silk screen typography and arrow symbols; see alternate application options on pg. 38
1/16” gap
View
57.875”
Lobby 2” Half Panel
Legend Panel — Chroma ® P: Chroma White Out FF: Renewable Matte
Elevators Parking Café Gift Shop Restrooms Waiting Rooms
Individual Legend Panels are detachable with magnetic attachments
Re s
Ad
mis
sio
nO
ffic
1
Wall Mounted Directional Scale 1:15
2
Isometric
WD
Scale NTS
rge
rm
gno sio
tro
e
ncy
ac y
stic
nD
Lo b o m s by Ele vat Par or s kin Ca g fé G if t Sh op
Placeholder panels
WD
Pha
I nf u
Admission Office Infusion Dept.
Em e D ia
Pharmacy Diagnostic Imaging
Header graphics. Adjust graphics to fit within alloted area. See section on Header Graphics.
Ima
e pt
.25” protruded and exposed surfaces of Legend Panels
g in
g
. Reverse silk screen printed surface on Chroma®. Background color in PMS 425 in matte eggshell finish.
*Obtain OSU brand PMS color
10.2010
36
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Wall Mounted Directional [WD]
Retainer Tray Inset groove with matching shape magnet attachment; act as alignment guides
Z Clips Full panel*
2
Level Two Name of Building
Emergency
Wall Magnet
View
Half panel*
Open
Level Fifteen Name of Building
Peri-Op Rm
Admission Office
Pharmacy
PACU
Reserch Labs 1-5
Diagnostic Imaging
Diagnostic Imaging
Rm 15100-15250
Admission Office
Surgery Rm
Rm 15251-15300
Infusion Dept.
Infusion Dept.
Research Labs 6-10
Lobby
Admission Office
Acute Care Unit
Parking
Peri-Pro Rm
Rm 15301-15350
CafĂŠ
CafĂŠ
Elevators
Enlarged View
4 15
Level Four Name of Building
Gift Shop
Scale 1:3
Restrooms Waiting Rooms
Blank placeholders
Blank placeholders
*Use Chroma White Out with renewable matte surface to block visibility of magnets / interanal hardware
1 WD
Wall Mounted Directional Scale 1:15
2 WD
Sample Layouts Scale 1:15
10.2010
37
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Small Wall Mounted Directional [SW]
24”
16”
.25”
2
1” Retainer Tray. Aluminum construction for structural rigidty; in non-glare, satin finish.
Header — Chroma ® P: Chroma White Out FF: Renewable Matte
Reverse silk screen printed surface on Chroma ®. Background color in OSU red* in matte eggshell finish.
Level Two Building Name 4”
Emergency Pharmacy
Em e
Silk screen typography and arrow symbols View
Pha
40”
D ia Ad
Diagnostic Imaging Legend Panel — Chroma P: Chroma White Out FF: Renewable Matte
Admission Office Infusion Dept.
Individual Legend Panels are detachable with magnetic attachments
Parking
Ad
mis
nO
ffic
stic
sio
sio
k in
ncy
ac y
gno
mis
Pa r sio
rge
rm
I nf u
®
Header graphics. Adjust graphics to fit within alloted area. See section on Header Graphics.
nO
nD
g
Ima
g in
ffic
e pt
.25” protruded and exposed surfaces of Legend Panels
g
e
.
e
*Obtain OSU brand PMS color in red
1 SW
Small Wall Mounted Directional Scale 1:10
2
Isometric
SW
Scale NTS
10.2010
38
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Details for WD and SW Ground color silk screen printed Symbols and typography left unprinted
Retainer Tray
Silk screened printed
Alternate Legend Application Option A Apply vinyl letters on top of pre-silk screened fields. Silk screened color fields are to be left unchanged and to be reused. Remove and reapply new vinly without damaging silk screened color surface during updates. Vinyl graphic
Vinyl letters
Silk screened printed 1/16� seam between Legend Panels Silk screened printed Protruded edge of Legend Panel
Emergency Pharmacy Parking Vinyl letters
Legend Panel
Indentation for matching magnetic plates on back of Legend Panels Ground color silk screen printed
1/16� seam between Legend Panels Indentation for matching magnetic plates
Silk screen printed background color field
Alternate Legend Application Option B Apply reverse cut vinyl graphic (letters and symbols) on first surface of an individual Legend Panel. Leave sides and edges clear of vinyl. Remove entire vinly graphic during updates.
Reverse cut vinyl graphic
Symbols and typography left unprinted
Open
1 TYP
Legend Panel
Details of Sign Type WD and SW Scale NTS
10.2010
39
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Wall Mounted Map [WM]
.5”
2
24”
16”
.75”
Retainer Frame
Header — Chroma ® P: Chroma White O ut FF: Renewable Matte
Header graphics. Adjust graphics to fit within alloted area. See section on Header Graphics. .25” protruded and exposed surfaces of Legend Panels Routed to receive clear acrylic Protective Panel
Level Two Building Name
View
Retainer Frame Aluminum construction for structural rigidty; in non-glare, satin finish.
Routed edge
High quality map output insert
40”
Chroma ® 23” 19 19 19 19 19 19 19 19
Destinations
De Em
Emergency
Emergency
Emergency
Infusion Deptartment
Infusion Deptartment
Infusion Deptartment
CTU/ Pharmacy
CTU/ Pharmacy
CTU/ Pharmacy
Outpatient Clinic
Outpatient Clinic
Outpatient Clinic
Pictogram One
Pictogram Four
Pictogram Two
Pictogram Five
Pictogram Two
Pictogram Five
Clear acrylic Protective Panel with diamond polished edges
1” Set screw
1 WM
Small Wall Mounted Directional Scale 1:10
stin
atio
erge Infu ncy sio CT n Dep U/ ta Ou Pharm rtmen tpat t ien acy tC linic
ns
Em
erge Infu ncy sio CT n Dep U/ ta Ou Pharm rtmen tpat t ien acy tC linic
19
Em erge Infu ncy sio CT n Dep U/ ta Ou Pharm rtmen tpat t ien acy tC linic
19 19 19 19 19 19 19
Pict ogra Pict m One ogra Pict m Tw o ogra m Tw o
Pict ogra Pict m Four ogra Pict m Fiv e ogra m Fiv e
Routed edge
2
Isometric
WM
Scale NTS
10.2010
40
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Floor Overview [FO]
Su
rg e PA r y — CU De — Pe D scr riO p e s c i p ti o rip n — D e ti o n s sc s rip ti o Ou ns tp O u a ti e nt tp Cl ini I n f a ti e c n us i o n t Cl i n — S o li ic De pa — H d Tu r tm m e en mo O or t nc olo g
Other levels are summarized
Surgery — Descriptions
Intravenous Radiation
PACU — Descriptions
Restrooms Vending Machines Family Waiting Room
Peri-Op — Descriptions
Level Four
OutpatientClinic — Solid Tumor
CTU
OutpatientClinic — Hemo Oncology
Pharmacy
Infusion Department
Restrooms Vending Machines Family Waiting Room
Level Two
Café Cafeteria Pharmacy
Diagnostic Imaging Adjacent Building
Restrooms Vending Machines Family Waiting Room
Conference Education
Pharmacy Lobby AMTU/ Apherisis Restrooms Vending Machines Family Waiting Room
Conference Rooms
Admissions Lobby
4 2
Ca fé Ca fe P h te r i a ar ma Re s cy Ve troo m n F din s am
1
g ily Ma W ch ait ine ing s Ro o
Vending Machines Family Waiting Room
Ground
CT
ve
no
us
Ra
dia
ti o
n
U
ar
m
ma
cy
Re st Ve room nd s Fa i n g Ma mi ly W chin ait e ing s Ro o Re st Ve room nd s Fa i n g Ma mi ly W chin ait e ing s Ro o
on
Co
G
ra
Di ag Ad n o s j a c ti c en Im t B ag u il i n g din g
Level One
Restrooms
y
Ph
Co
nf Ad e re n ce m Lo issio Edu bb ca ns ti y
Int
Current level presented on Chroma ® panel mounted on wall
nfe
re
nc
eR
oo
ms
AM
Le
ve
Le
ve
Floor Overview Wayfinding at Elevator Landing
2
Isometric
FO
Scale NTS
FO
Scale NTS
ou
r
lT wo
4 2
Fa e n d R e mil in st y W g M roo ait ach ms ing ine Ro s om
m
Gr
1
lF
m
Ph ar ma TU c / A Lo b y p h by er isi s V
Re st Ve room nd s Fa i n g Ma mi ly W chin ait e ing s Ro o
Summary of current level uses lists of legends and pictograms
m
ou
nd
G
Dimensional level indicator (for current level only)
10.2010
41
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Floor Overview [FO]
1”
Surgery — Descriptions
Intravenous Radiation
PACU — Descriptions Peri-Op — Descriptions
Restrooms Vending Machines Family Waiting Room
Level Four
OutpatientClinic — Solid Tumor
CTU
OutpatientClinic — Hemo Oncology
Pharmacy
Restrooms Vending Machines Family Waiting Room
Infusion Department
Level Two
10”
Café Cafeteria Pharmacy
Diagnostic Imaging Adjacent Building
Pharmacy Lobby AMTU/ Apherisis
Restrooms Vending Machines Family Waiting Room
Conference Education
Restrooms Vending Machines Family Waiting Room
Conference Rooms
Admissions
Restrooms Vending Machines
Ground
TBD (60” est.)
1
Level One
Family Waiting Room
Lobby
4 2
G
.125”
Vinyl typography and graphics apply directly on wall
Display Panel — Chroma ® P: Chroma White Out FF: Renewable Matte
View
TBD (35” est.)
10”
Vinyl typography and graphics Z Clips; Display Panels are detachable
Retainer Frame Aluminum construction in non-glare, satin finish
1
Floor Overview Wayfinding at Elevator Landing
2
Side View
FO
Scale 1:10
FO
Scale 1:3
.5”
10.2010
42
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Podium Elevator Landings — Public Information
Formal sign product or digitally printed wallpaper
Wall mounted evacuation map offers wayfinding overview
Reinforcing indicators visible from inside cab are additional options End wall exiting elevator landing is key to orientation and wayfinding
Surgery — Descriptions
Intravenous Radiation
PACU — Descriptions
Restrooms Vending Machines Family Waiting Room
Peri-Op — Descriptions
Level Four
OutpatientClinic — Solid Tumor
CTU
OutpatientClinic — Hemo Oncology
Pharmacy
Restrooms Vending Machines Family Waiting Room
Infusion Department Level Two
Café Cafeteria Pharmacy
Pharmacy Lobby AMTU/ Apherisis
Restrooms Vending Machines Family Waiting Room
Restrooms Vending Machines Family Waiting Room
Conference Education Admissions Lobby
1 TYP
Conference Rooms
4 2
1
Summary of other levels
Current level in summary
Level One
Restrooms Vending Machines Family Waiting Room
Ground
G
Elevator Landing Scale NTS
10.2010
43
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Double Door Identification Sign [DD]
Panel at the Left Side of Door
Panel at the Right Side of Door
This panel is reserved for restrictions,cautions, and other mandatory information. Color usage consistent with visual coding system for messaging.
All directional and other wayfinding information on this panel presented with arrow(s) and legends.
High quality insert Set screw; inconspicuously installed at top and bottom
.5” Set screw
Routed edge
Chroma ® P: Chroma White Out FF: Renewable Matte Routed to receive clear acrylic panel
12” .5”
Header or pictogram panel
Critical Care Rooms
12”
Nurses’ Station A
Pro Equper Reqipme Pri uir nt or to E ed R
Main Equipment Room Examination Rooms Surgery Rooms
Description or destination panel (detachable)
Proper Equipment Required Prior to Entry
Cri tica Nu l Car r se eR Ma s’ Sta oom s in E tio Exa quip n A me mi Su natio nt R rge n R o om Ro ry Ro oom om om s sP 09 s 115 -P 09 130
Rooms P09115 - P09130
View
adi ntr o y Do active No E N m t E n t q uip m e en re r d e l r u m h w i th o t . ec ut ic vol tus, u tenet prem u pt t a u u i atib t re r a sa ssion . i p us ma ciend iente io r e i s s al ia s
TBD*
Radioactive Equipment. Do Not Enter without premission. Nm rerum hic tenetur a sapiente delectus, ut aut reiciendisperferendis doloribus asperiores repellat
1”
Set screw
Chroma ® routed to receive clear acrylic panel
*Total length of sign to match length of adjacent window
1
Double Door Identification
2
Isometric
DD
Scale 1:10
DD
Scale NTS
Back Panel; 1/8” frosted acrylic panel Set screw
Clear acrylic panel with diamond polished edges Routed edge
10.2010
44
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Double Door Identification Sign [DD]
Critical Care Rooms
Main Equipment Room
Nurses’ Station A
Examination Rooms
Main Equipment Room
Surgery Rooms
Examination Rooms
Biohazard Materials Ahead
Rooms P09115 - P09130
Restricted Zone Beyond This Point
Critical Care Rooms
Entry Restricted
Nurses’ Station A
Radioactive Equipment. Do Not Enter without premission. Nm rerum hic tenetur a sapiente delectus, ut aut reiciendis voluptatibus
Examination Rooms
Do Not Enter
Main Equipment Room
Radioactive Equipment. Do Not Enter without premission. Nm rerum hic tenetur a sapiente delectus, ut aut reiciendis voluptatibus maiores alias.
Sign mounted on both sides of door at eye level
Critical Care Rooms Nurses’ Station D Rooms P09115 - P09130
Critical Care Rooms Nurses’ Station A Main Equipment Room Examination Rooms
1
Sample Layout
2
Sample Layout
DD
Scale NTS
DD
Scale NTS
Hospital Staff Only
Prior to Entry
Critical Care Rooms Nurses’ Station A Main Equipment Room Examination Rooms
Radioactive Equipment. Do Not Enter without premission. Nm rerum hic tenetur a sapiente delectus, ut aut reiciendis voluptatibus maiores alias
Critical Care Rooms
Critical Care Rooms
Nurses’ Station A
Nurses’ Station D
Main Equipment Room
Examination Rooms
Examination Rooms
Surgery Rooms Rooms P04115 - P04130
Surgery Rooms
No High Entry Without Powered Badge Magnets
Proper Equipment Required
Surgical Attire Required
Rooms P09115 - P09130
Hospital Only CautionStaff to Visitors
Prior to Entry
Do Enter NmNot rerum hic without tenetur apremission. sapiente Nm rerumuthic tenetur a sapiente delectus, aut reiciendis. Nm delectus, aut reiciendis rerum hicut tenetur a sapiente voluptatibus maiores alias. delectus, ut aut reiciendis.
Radioactive Equipment. Do Not Enter without premission. Nm rerum hic tenetur a sapiente delectus, ut aut reiciendis voluptatibus maiores alias.
with Pacemakers Radioactive Equipment.
Critical Care Rooms Examination Rooms
3
Sample Layout
4
Sample Layout
5
Typical Elevation
DD
Scale NTS
DD
Scale NTS
DD
Scale 1:20
10.2010
45
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
“Hospital Staff Only” Access Identification
Hospital Staff Only
Overhead in public circulation
Icon as part of the double door identification with infomation or instructions
P04181 Hospital Staff Only
Stand alone door mount at larger scale than double door identification signs
Hospital Staff Only
No Entry Without Badge
Scan badge at check-in counter at nurses’ station
Hospital Staff Only
Hospital Staff Only
Radioactive Equipment. Do Not Enter without premission. Nm rerum hic tenetur a sapiente delectus, ut aut reiciendis voluptatibus maiores alias.
Hospital Staff Only
Adjacent to door as sign module
Hospital Staff Only
Icon and blue field are part of the graphics on insert
Individual room signs can be coded for “Hospital
Hospital Staff Only Mark
Staff Only” using the “H” mark and its easily
Familiar “H” mark in hospital blue field plays role in coding
identifiable blue field as part of visual elements of
accessibility information. Use for restriction and filtering of
the room sign.
content and access.
1
Room Sign Sample Layout
2
Typical Elevation
HS
Scale NTS
HS
Scale 1:20
10.2010
46
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Overhead Directional [OD]
TBD
EMERGENCY
AMTU/Apherisis 1”
88”
8”
1”
3”
1”
.125”
Retainer Frame attached to Vertical Support Tube
EMERGENCY
8”
.125” Retainer Frame
1 OD
Overhead Directional Scale 1:20
Vertical Support
Vertical Support
Portruded edge in Chroma ®
Portruded edge in Chroma ®
.5”
Enlarged View Scale 1:4
2
Side View
OD
Scale 1:20
2”
.5”
Enlarged View Scale 1:4
10.2010
47
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Overhead Directional [OD]
Retainer Frame
Vertical Support. Aluminum construction for structural rigidty; in non-glare, satin finish.
Inset for Legend Panel
Retainer Frame. Aluminum construction for structural rigidty; in non-glare, satin finish.
Ra dio log
Optional to apply an additional layer of eggshell white opaque paint to the second surface of Legend Panels to reduce translucency of double sided signs
y
Ra dio log
3M vinyl for typography and symbols
EM Legend Panel — Chroma ® P: Chroma White O ut FF: Renewable Matte
ER GE NC
y
Vertical Support
Y
EM
Legend Panel inset into Retainer Frame
Open
1
Isometric
OD
Scale NTS
ER GE NC
Y
10.2010
48
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Large Overhead Directional [LO]
TBD
EMERGENCY Diagnostic Imaging Elevators
AMTU/Apherisis Pharmacy Lobby 1”
88”
16”
1”
3”
Vertical Support
Vertical Support .125”
Portruded edge of Chroma ® Legend Panel
.5”
2”
.5”
Portruded edge of Chroma ® Legend Panel
1” Retainer Frame
1
Large Overhead Directional
LO
Scale 1:20
Double sided presentation
10.2010
49
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Large Overhead Directional [LO]
Retainer Frame Inset for Legend Panel Vertical Support. Aluminum construction for structural rigidty; in non-glare, satin finish.
Optional to apply an additional layer of eggshell white opaque paint to the second surface of Legend Panels to reduce translucency of double sided signs
Retainer Frame. Aluminum construction for structural rigidty; in non-glare, satin finish.
3M vinyl for typography and symbols
Vertical Support
Legend Panel — Chroma ® P: Chroma White Out FF: Renewable Matte
1
Isometric
LO
Scale 1:NTS
Legend Panel inset into Retainer Frame
Open
10.2010
50
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Perpendicular Announcer [PA]
Open
Vinyl for typography and symbols
1.5” 3”
24”
.25”
.25”
.125”
Outpatient Registration
4”
Portruded edge of Chroma ®
Portruded edge of Chroma ®
.125” .125”
.125”
Fasteners attached to wall; flush to frame
.125”
Aluminum Retainer Frame
Legend Panel — Chroma ® P: Chroma White Out FF: Renewable Matte
Aluminum Retainer Frame
1
Perpendicular Announcer
2
Side View
PA
Scale 1:5
PA
Scale 1:5
10.2010
51
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Perpendicular Announcer [PA]
Retainer Frame Open Fasteners; install flush to frame
Optional to apply an additional layer of eggshell white opaque paint to the second surface of Legend Panels to reduce translucency of double sided signs Retainer Frame. Aluminum construction for structural rigidty; in non-glare, satin finish.
Ou tpa tie nt Re gis tra tio n
Legend Panel — Chroma ® P: Chroma White Out FF: Renewable Matte
Ou tpa tie nt Re gis tra tio n Legend Panel inset into Retainer Frame
1
Isometric
PA
Scale NTS
10.2010
52
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Perpendicular Pictogram [PP]
1.5”
Pictogram — Clear acrylic panel. Silk screen front surface with matte paint. Leave sides unpainted. Diamond polish all exposed edges.
8”
.125” Portruded edge of Chroma ®
Raised picotogram 8”
Raised picotogram
Portruded edge of Chroma ® .125”
.125”
.125”
Aluminum Retainer Frame
1
Perpendicular Pictogram
2
Side View
PP
Scale 1:3
PP
Scale 1:3
10.2010
53
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Perpendicular Pictogram [PP]
Fasteners; install flush to frame
10ft. Ceiling
9ft. Ceiling Retainer Frame. Aluminum construction for structural rigidty; in non-glare, satin finish.
90”
Raised pictogram
Pictogram Panel — Chroma ® P: Chroma White Out FF: Renewable Matte
1
Perpendicular Pictogram
2
Typical Installation Height
PP
Scale 1:3
PP
Scale 1:25
10.2010
54
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Movable Stanchion [MS]
Clear acrylic slot for paper insert: 8.5” x 11”
Chroma ®
Stainless steel
13” 13”
Stainless steel ”
5 .2
16
Authorized Personnel Only Do Not Enter
.25”
Chroma ®
1.5” 21.5”
Exposed edges of Chroma ® panel; sand and smooth to match finish on face
45” 39”
Use additional counter balance weight if necessary (enclosed within base)
12”
.5” Stainless steel base; non-glare with satin finish
open
6.5”
.5” 1”
1 MS
Movable Stanchion Scale 1:20
2 MS
Right Side View Scale 1:20
3
Isometric
MS
Scale NTS
10.2010
55
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Systematic Presentation of Pictograms Pictogram System
The retangular facade of the OSU logo graphic leads to the presentation of facility pictograms in square frames. See sample pictogram set below.
Usage of international and universal symbols presented in a visually-consistent, systematic way. The pictograms are individually framed by a 6� x 6� square fabricated with familiar materials as used on the larger freestanding signs. Supplementary legends are assigned to a designated zone either at top or bottom of square.
Level
Level
Level
Level
15 G T R
Pictogram Zone
Back
Public
9
Level
Lower Legend Zone Layout allows for legend to accompany pictogram fallling within a consistent zone
Public
Patients
Automated
Freight
Men
Women
Restroom
Family
Stairs
Alarm
Exit
Upper Legend Zone Layout allows for legend to accompany pictogram fallling within a consistent zone
Accessible
STOP
Restricted
No Access
Warning
Prohibited
Personnel
Biohazard
Some pictograms can be used with colors /color field to draw attention to sign
10.2010
56
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Organizing Elements on Horizontal Rule
Labels Significant Donations/ Donor Recognition
Significant Decision Points
Visually separate name and horizontal rule using two distinctive metallic tones/finishes.
Pictogram square plaques can be used along with dimensional legend sharing
The donor’s significance can be further emphasis by adjusting scale of the names.
the same horizontal rule. Chroma ÂŽ blocks with gray silk screen graphics
Metal tone A
Metal tone B
1501 to 1549 Metallic rule
Significant Department Destination
Significant Decision Points
Dimensional department name painted in white situated on a metallic rule. Subtext as
Pictograms, legends, and horizontal rule suspended from ceiling as one unit.
White paint letters
part of name can be included by adding an extra line below. 3M vinyl typography and graphics White paint letters
Name
Subtext
Outpatient Clinic Hemo Oncology
Rooms
1501-1549 Retainer Frame
Metallic rule
Seams create visual separation
10.2010
57
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Organizing Elements on Horizontal Rule
Precedent images of dimensional letters on horizontal rule
10.2010
58
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Flexible Combinations Using Simple Shapes
Rooms
3D letters on metal rule
1501-1549
Dorthy Citizen Wing
Pictograms as flag signs lead and identify; vertical orientation
Square plaques are larger in size when at the point of destination
Hazard and warning add on left to right atop mounting bar Icon squares lead at corners
1501 to 1549
04252 to
Restricted Zone
Radiation III Contents & Activity
Eye Protection Required
Eye Wash Available
04352
3D letters on metal rule with icon square(s) atop
1 TYP
Typical Elevation Scale 1:25
10.2010
59
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Corner Mounted Directional [CD] Align text and graphics to corner break
.625”
12”
Chroma
1”
3/8” Ecoresin Legend Panel with routed top & bottom edges
09
Rooms 09150-09180
Rooms 09150-09180
Vinyl typography and symbols
40”
30 R Cl 0 - 0oom a 21 ssro93 1 s 1-2 o 0 20 ms
va 09 t 3 1 Ro o r s 1- 0 om 93 s 09 32 Ro 20 1- 0 om 93 s 30
Elevators Rooms 09181-09200 Rooms 09201-09230
1”
Elevators Rooms 09181-09200 Rooms 09201-09230
1
21
Ele
45˚ matching break on two panels creating a 90˚ break
View
0 s 918 om - 0 s Ro 15 0 oom 9 r s 0 as 0 Cl -22
rs to va 00 E l e m s 92 o -0 Ro 18 1 30 0 9 m s 0 92 o Ro 20 1 9 0
90° Break
.25” frosted acrylic back panel
Chroma
1” Set screw
1
Corner Mounted Directional
2
Side View
3
Plan View
4
Typical Elevation
5
Isometric
CD
Scale 1:10
CD
Scale 1:10
CD
Scale 1:10
CD
Scale 1:25
CD
Scale NTS
10.2010
60
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Corner Mounted Pictogram [CP]
5.75”
5.75”
5.75”
.5”
.25”
5.75”
View
5.75”
Emergency .25” Three-Up Arrangement .625” Set screw per pictogram
Set screw
Retainer Frame. Aluminum construction for structural rigidty; in non-glare, satin finish.
View
Pictogram Panel* — Chroma ® P: Chroma White Out FF: Renewable Matte Two-Up Arrangement
Silk Screened typography and symbols
*Optional to use Ecoresin for lowering material cost
1
Corner Mounted Pictogram
2
Side View
CP
Scale 1:4
CP
Scale 1:4
10.2010
61
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Corner Mounted Pictogram [CP]
Emergency
1
Typical Elevation
2
Isometric
CP
Scale 1:25
CP
Scale NTS
10.2010
62
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Destination Vocabulary Per Department
Diagnostic Imaging Reception and Patient Sign In For after hours assistance and information call 123-456-7890 or visit www.departmentname.com
Slot fixture backlights imagery of department’s competency
Diagnostic Imaging
Three dimensional legend on horizontal rule indicating department name
Department name on pylon
Front Desk & Patient Sign In
Additional information as vinyl graphics located underneath department name
Distinct color of department repeated as part of the consistent visual vocabulary
Distinct color unique to this department. Preferably using a pronounce-able color
1 TYP
Department Entry Scale NTS
2 TYP
Reception Desk Scale NTS
10.2010
63
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Door Mounted Safety Informational [DS]
Door 6”
.25”
.125”
1/8” Spacer Panel
6”
Spacer
Routed edges View
Insert Holder .25”
3F Varia Ecoresin Style: White Out FF: Supermatte BF: Supermatte
Insert slot
View
Radiation III
Ecoresin insert holder
Routed edges
Protective Panel — Clear acrylic with routed and polished edges
Contents & Activity
.375”
.375”
.375”
1
Layout Detail (Single Insert)
2
Side View
3
Plan View
DS
Scale 1:2
DS
Scale 1:2
DS
Scale 1:2 10.2010
64
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Door Mounted Safety Informational [DS]
High Voltage Zone Additional Information
Additional Insert printed with precise cautionary details or instructions
Card stock insert
Ra Insert for main message
1
Layout Detail (Double Arrangement)
DS
Scale NTS
Supplementary information on adjacent insert; option to use for billingual information
dia
tio n Co
nte
nt s
&A
III
c tiv
it y
Ey eP
rot Re ecti qu o n ire d
Clear acrylic slides down into Insert Holder
3F Varia Ecoresin routed to form an Insert Holder
Restricted Zone
Radiation III Contents & Activity
Eye Protection Required
Eye Wash Available
2
Layout Detail (4-Up Arrangement)
3
Isometric
DS
Scale NTS
DS
Scale NTS 10.2010
65
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Door Mounted Safety Informational [DS]
Restricted Zone
High Voltage Zone
Radiation III Contents & Activity
Additional Information
Eye Protection Required
Eye Wash Available
1
Layout Detail (1-Up Arrangement)
4
Layout Detail (4-Up Arrangement)
DS
Scale NTS
DS
Scale NTS
Restricted Zone
High Voltage Zone ADDITIONAL INFORMATION
Restricted Zone
High Voltage Zone ADDITIONAL INFORMATION
Radiation Iii CONTENTS & ACTIVITY
CONTENTS & ACTIVITY
Spontaneously Combustible
Spontaneously Combustible
1.25�
High Voltage Zone
Radiation
Gloves Required
Eye Protection Required
Eye Wash Available
Chemical Shower Available
Additional Insert printed with precise cautionary details or instructions
Additional Information
Gloves Required
Eye Protection Required
2
Layout Detail (2-Up Arrangement)
5
Layout Detail (6-Up Arrangement)
DS
Scale NTS
DS
Scale NTS
Restricted Zone
High Voltage Zone ADDITIONAL INFORMATION
Restricted Zone
Radiation III Contents & Activity
Radiation Iii CONTENTS & ACTIVITY
Spontaneously Combustible
Eye Protection Required
Gloves Required
Eye Protection Required
Eye Wash Available
Chemical Shower Available
3
Layout Detail (3-Up Arrangement)
6
Layout Detail (8-Up Arrangement)
7
Typical Elevation
DS
Scale NTS
DS
Scale NTS
DS
Scale 1:20 10.2010
66
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Insert Holders (IH)
Insert
Adhere sign directly to wall
White painted masking border
1/16” Clear acrylic, polished edges; masking border painted in white on second surface
11.25”
1/16” Frosted polycarbonate; cut to shape as pocket for inserts and hidden behind masking border
.25”
1/8” Frosted polycarbonate
Insert Total display area is 10.75” x 8.25”. Letter size insert is visually insetted .125” within the masking border
8.75”
Wall
Insert
View
.75” .75” .25” .25”
Vertical Placement
Finger slot
Horizontal Placement
1
Insert Holder — 8.5” x 11”
2
Side View
IH
Scale 1:4
IH
Scale 1:4
10.2010
67
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Large Insert Holders (IL)
Adhere sign directly to wall White painted masking border
1/16” Clear acrylic, polished edges; masking border painted in white on second surface
17.25”
1/16” Frosted polycarbonate; cut to shape as pocket for inserts and hidden behind masking border
.25”
1/8” Frosted polycarbonate
Total display area is 16.75” x 10.75”. Letter size insert is visually insetted .125” within the masking border
11.25”
View
Insert
.75” .75” .25” .25”
1
Large Insert Holder —11” x 17”
2
Side View
IL
Scale 1:4
IL
Scale 1:4
10.2010
Code Required Signs Sign Detail and Application
69
Sign Codes
Ohio State University Medical Center Columbus | Ohio
Signage Related Code Compliance Code Required Signs
This effort identifies the four codes applied to this project and excerpts the text related to signage from each document. These excerpts are displayed
2007 Ohio Building Code An Amended Version of the 2006 International Building Code
next to the drawing of the resultant compliant sign. These assumed answers should be reviewed for approval by the project code consultant. They should also be submitted to the client for review for compliance with any idiosyncratic, internal rules unknown to us. Finally, these signs should be
ICC/ANSI A117.1 - 1998 Accessible and Usable Buildings and Facilities as Adopted and Amended by Chapter 11 of the 2007 Ohio Building Code
offered to the Fire Marshall with authority over this site.
NFPA 101 Life Safety Code, 2000 and 2006 As Enforced by Centers for Medicare and Medicaid Services (CMS) and The Joint Commission on Accreditation of Healthcare Organizations (TJC)
ADAAG For Titles I (Employees) and III (Public Accommodation)
10.2010
70
Braille
Ohio State University Medical Center Columbus | Ohio
Codes and Examples ANSI 117.1 — 1998
4 Digit Room Numeral
Braille
Letter Prefix
Type Braille shall be contracted (Grade 2) Braille.
Signals building name
P1234A
Dimensions Braille dots shall have a domed or rounded shape and shall comply with Table 703.4.3 (below).
Distance between dots in adjacent cell Single Braille cell
Distance between dots in the same cell Distance between corresponding dots from one cell directly below
a room (also “T” for toilet, “M” for mechanical, “J” for janitorial). Exception: No “O” or “I” to avoid confusion with zero or one.
Braille Position Braille shall be below the corresponding text. If text is multi-lined, Braille shall be placed below entire text. Braille shall be separated 3 /8 inch (9.5 mm) minimum from any other tactile characters and 3/8 inch (9.5 mm) minimum from raised borders and decorative elements. Braille provided on elevator car controls shall be separated 3/16 inch (4.8 mm) minimum either directly below or adjacent to the corresponding raised characters or symbols.
Distance between dots in the same cell
Letter Suffix for labeling room inside
5 Digit Room Numeral
If we change to 5 digit room numeral the floor can be incorporated (and
P19.123A
signaled by a dot or dash between
12140 floor number and room number).
P1234A
Blank cell space between words Raised dot
Dot diameter No raised dot
3/8”
Table 703.4.3 10.2010
71
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Room Number [RN] and Room Insert [RI] ANSI 117.1 — 1998 Tactile Characters Depth: Must be raised 1/32” (0.8 mm) minimum.
P12345
Case: All uppercase. Indication of an uppercase letter or letters shall only be used before the first word of sentences, proper nouns and names, individual letters of the alphabet, initials, Tactile Room Number
or acronyms. Style: San serif (no italic, oblique, script or decorative). Height: 5/8” (16 mm) height minimum.
5.625”
2” (51 mm) height maximum. Use uppercase “I” to determine character height. Exception: Can be 1/2” (13mm) if tactile and visual characters provide the same information. Width: Characters shall be 55% minimum and 110% maximum width of the uppercase character height. Use uppercase “O” to
2.75”
determine character width.
P12345
Character Spacing: Character spacing shall be measured
1/8” EcoResin Back Plate
Hemo Oncology
Clear Engraving Stock Silk screened on surface only, leaving sides clear. Matte finish in PMS 425. 1/16” thick.
Dr. Mallisu Dr. York
View ADA compliant braille
between the two closest points of adjacent tactile characters within a message, excluding word spaces. Spacing between
Braille
individual tactile characters shall be 1 /8 inch (3.2 mm) minimum measured at the top surface of the characters, 1 /16 inch (1.6 mm) minimum measured at the base of the characters, and four times the tactile character stroke width maximum. Characters shall be separated from raised borders and decorative elements 3 /8 inch (9.5 mm) minimum.
Room Available
Line Spacing: Spacing between the base lines of separate lines of tactile characters within a message shall be 135% minimum and 170% maximum of the tactile character height. Finish and Contrast: Characters and their background shall have a non-glare finish. Characters shall contrast with their background, with either light characters on a dark background, or dark characters on a light background.
1 RN
Room Sign [RN] — Room Number Only
2
Room Sign [RI] — Room Number with Inserts
Scale 1:2
RI
Scale 1:2
10.2010
72
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Room Insert [RI] Color Adaptation and Layouts Using visual coding of signs to overcome visual clutter. Messages are presented with a consistent color-coding. Requires consistent look of message vehicles and message layouts — it is the coloration of codes.
P09156
P15153
P12008
P12345
Examination Room
Nurse’s Station
Emergency Supplies
Emergency Supplies
Dressing Room and Restroom
Check In Prior to Entry
Fire Extinguishers Backup Batteries Portable Life Support Devices
Fire Extinguishers Backup Batteries Portable Life Support Devices
Messages to Public
P12033
Messages for Practitioners
P13451
Pathology Lab
CT Scanner
Biohazard Materials. Do Not Enter Without Protective Gear. Unauthorized Personnel Not Permitted
High Radiation Area Do Not Enter Without Protective Gear
Caution Attention Messages
Hazard Warning Messages
Life Safety Messages
P10106 Critical Care Surgery Room Disinfectant Procedure and Surgical Attire Required Prior to Entering Room
Equipment Requirement Messages
Life Safety Messages
P04181 Surgical Supplies Surgery Scrubs and Other Auxiliary Supplies
Equipment Availability Messages 10.2010
73
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Retrofitted Room Insert [RI] Note: This layout is designed specifically for use in ProjectONE. 5.625”
P12345
2.75”
1/8” EcoResin Back Plate
.625”
Clear Engraving Stock Silk screened on surface only, leaving sides clear. Matte finish in PMS 425. 1/16” thick.
1”
.375”
ADA compliant braille
Braille .375” .25”
Raised insert display .375”
Hemo Oncology Dr. Mallisu Dr. York
White painted masking border
1/16” Paper Insert Spacer 1/8” Acrylic Spacer
Quarter page of an 8.5” x 11” size paper; use medium cover stock paper or regular folded sheet
View 4”
5.75”
1/16” Paper Insert Spacer Main insert display window
.75”
.25”
Patient advisory window
Room Available
1”
.75”
1/8” Clear acrylic, polished edges; paint white masking border on second surface
Edges of insert are hidden behind masking border
.25”
5.375” .25”
1 RI
1/16” Paper Insert Spacer
Finger slot
Retrofitted Room Insert [RI]
2
Isometric
Scale 1:2
RI
Scale: NTS
Patient advisory insert
10.2010
74
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Retrofitted Room Insert [RRI] Note: This is a retrofitted design (usage optional) and is its size 7.75”
and layout based on existing signage currently in use on campus. Requested by client in design review meeting on 10.15.2010.
P12345
2.75”
.625”
1/8” EcoResin Back Plate Clear Engraving Stock Silk screened on surface only, leaving sides clear. Matte finish in PMS 425. 1/16” thick.
1”
.375”
ADA compliant braille .375”
.375”
Raised insert display
Hemo Oncology
1/8” Acrylic Spacer
1/16” Paper Insert Spacer
Dr. Mallisu Dr. York
White painted masking border
Quarter page of an 8.5” x 11” size paper; use medium cover stock paper or regular folded sheet
View 4.125”
6.25” .5”
Main insert display window
.75”
.375”
Room Available
Patient advisory window
1/8” Clear acrylic, polished edges; paint white masking border on second surface
1”
Edges of insert are hidden behind painted masking border
.375”
1/16” Paper Insert Spacer Patient advisory insert
7.25” .5”
1 RRI
Retrofitted Room Insert [RI] Scale 1:2
Finger slot
2
Isometric
RRI
Scale: NTS
10.2010
75
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Patient Room Sign [PR] Patient Room Sign with Slidable Patient Care Placards
Patient Care Placards and Paper Grip Rail
Tactile and Braille header indicating room number with a window for paper insert. When placards are not in use, they are hidden from view.
Patient care information icons are displayed on placards that can be locked or unlocked, slide in or out, and customizable as needed per department or unit. Additional notes or documents regarding the occupant can be attached to a paper grip rail located at the bottom of the sign. Patient care placards
5.625”
2.75”
P12345
P12345 npo
Critical Care Unit 5.75”
Patient’s Name Doctor’s Name (AM) Doctor’s Name (PM) Nurses’ Names
Option: Face of sign fabricated as a single hinged flap to open for further messages; paper grip removed
P12345
Critical Care Unit
npo
Critical Care Unit Patient’s Name Doctor’s Name (AM) Doctor’s Name (PM) Nurses’ Names
Patient’s Name Doctor’s Name (AM) Doctor’s Name (PM) Nurses’ Names
18” See ANSI 117.1 installation requirements
.5” Possible medication side effects include: "Sed ut perspiciatis unde omnis iste natus error sit voluptatem accusantium doloremque laudantium, totam rem aperiam, eaque ipsa quae ab illo inventore veritatis et quasi architecto beatae vitae dicta sunt explicabo. Nemo enim ipsam voluptatem quia voluptas sit aspernatur aut odit aut fugit, sed quia.
Additional information of this signtype can be found at www.lhsigns.com
Paper grip rail under signs at key location
Extra surface for messages
Notes regarding room can be attached
Patient Care Sign
Patient Care Sign
Typical Elevation
Scale: 1:3
Scale: 1:3
Scale: 1:25
10.2010
76
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Stairway Identification [SI] ANSI 117.1 — 1998 Pictogram Field
Tactile Legend
Same as for pictogram signs if pictograms are used. Tactile Characters
Ecoresin® or frosted polycarbonate
6.125”
Refer to specifications on Tactile and Braille page. Braille
.5”
West Stair C
Refer to specifications on Tactile and Braille page.
1/16”
West Stair C
IBC — 2006
.625”
.375”
.25”
1011.3 Tactile Exit Signs A tactile sign stating EXIT and complying with ICC A117.1
4.125”
shall be provided adjacent to each door to an area of refuge, an exterior area for assisted rescue, an exit stairway, an exit ramp, an exit passageway and the exit discharge.
West Stair C
NFPA 101 — 2006 10.5”
7.10.1.3 Exit Door Tactile Signage
3.5”
EXIT
Tactile signage shall be provided to meet the following criteria, unless otherwise provided in 7.10.1.4: (1) Tactile signage shall be located at each exit door requiring an exit sign. (2) Tactile signage shall read as follows: EXIT. (3) Tactile signage shall comply 18”
7.2.2.5.4 Stairway Identification
EXIT
Stair identification needs to be letters not numbers. These signs to be located on the occupancy or entrance side of the stairwell.
EXIT
.25”
.75”
Braille
See ANSI 117.1 installation requirements
.625” .375”
Clear Engraving Stock Printing on surface only, leaving sides clear. Matte finish paint. 1/16” thick.
.25”
Front View
Basic Layout — Front and Side View
Typical Elevation
Scale: 1:3
Scale: 1:3
Scale: 1:25
10.2010
77
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Stair Sign [SS] NFPA 101 — 2006 7.2.2.5.4* Stairway Identification 7.2.2.5.4.1 New enclosed stairs serving three or more stories
(K)* Signage that reads NO ROOF ACCESS and is located under
and existing enclosed stairs serving five or more stories shall
the stairway identification letter shall designate stairways that
comply with 7.2.2.5.4.1(A) through (M).
do not provide roof access. Lettering shall be a minimum of
Stair East
1 in. (25 mm) high and shall be in accordance with 7.10.8.2.
15
(A) The stairs shall be provided with special signage within the enclosure at each floor landing.
(L) The floor level number shall be located in the middle of the sign in minimum 5 in. (125 mm) high numbers and shall be in
(B) The signage shall indicate the floor level.
accordance with 7.10.8.2. Mezzanine levels shall have the letter “M” or other appropriate identification letter preceding
(C) The signage shall indicate the terminus of the top and
the floor number, while basement levels shall have the letter “B”
bottom of the stair enclosure.
or other appropriate identification letter preceding the floor level number.
(D) The signage shall indicate the identification of the stair enclosure.
(M) Identification of the lower and upper terminus of the stairway shall be located at the bottom of the sign in minimum
(E) The signage shall indicate the floor level of, and the direction
1 in. (25 mm) high letters or numbers and shall be in accordance
to, exit discharge.
with 7.10.8.2.
(F) The signage shall be located inside the enclosure
7.2.2.5.4.2 Wherever an enclosed stair requires travel in an
approximately 60 in. (1525 mm) above the floor landing in a
upward direction to reach the level of exit discharge, special
position that is visible when the door is in the open or closed
signs with directional indicators showing the direction to the
position.
level of exit discharge shall be provided at each floor level
Re-Entry on L5-10 Down to 1ST Floor For Exit Discharge
landing from which upward direction of travel is required, unless (G) The signage shall comply with 7.10.8.1 and 7.10.8.2 of this
otherwise provided in 7.2.2.5.4.2 (A) and 7.2.2.5.4.2(B), and
Code.
the following also shall apply: (1) Such signage shall comply with 7.10.8.1 and 7.10.8.2.
(H) The floor level designation shall also be tactile in accordance
(2) Such signage shall be visible when the door leaf is in the
with ICC/ANSI A117.1, American National Standard for
open or closed position.
Accessible and Usable Buildings and Facilities. (A) The requirement of 7.2.2.5.4.2 shall not apply where signs (I) The signage shall be painted or stenciled on the wall or on a
required by 7.2.2.5.4.1 are provided.
separate sign securely attached to the wall. (B) The requirement of 7.2.2.5.4.2 shall not apply to stairs (J) The stairway identification letter shall be located at the top
extending not more than one story below the level of exit
of the sign in minimum 1 in. (25 mm) high lettering and shall be in
discharge where the exit discharge is clearly obvious.
accordance with 7.10.8.2.
Front View Scale: 1:3
10.2010
78
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Stairway Identification [SI]
6.125”
Stair East
Tactile Type
.5”
15
Braille
Tactile Level Number 12.25”
Tactile Type
.375”
1”
1”
1/8” Spacer
.75”
Stair East
15
5”
Re-Entry on L5-10 Re-Entry on L5-10 Down to 1 ST Floor For Exit Discharge
Clear Acrylic with Painted Face
1”
Re-Entry on L5-10 Down to 1ST Floor For Exit Discharge
Tactile Type
Ecoresin® or frosted polycarbonate
.25”
Clear Engraving Stock Printing on surface only, leaving sides clear. Matte finish paint. 1/16” thick.
.625”
18” See ANSI 117.1 installation requirements
1.625”
.25”
Basic Layout — Front and Side View
Typical Elevation
Scale: 1:3
Scale: 1:25
10.2010
79
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Elevator Landing Signs [EL] IBC — 2006 7.10.8.4 Elevator Signs Elevators that are a part of a means of egress (see 7.2.13.1) shall have the following signs with a minimum letter height of 3”
5/8” (16 mm) posted in every elevator lobby: (1)* Signs that indicate that the elevator can be used for egress,
Ecoresin® or frosted polycarbonate
Silk screened typography and graphics
including any restrictions on use;
In Fire Emergency, Do Not Use Elevator. Use Exit Stairs.
(2)* Signs that indicate the operational status of elevators.
7.10.8.5* Evacuation Map Where a posted floor evacuation map is required in Chapters 11 through 43, floor evacuation diagrams reflecting the actual floor
In Fire Emergency, Do Not Use Elevator. Use Exit Stairs.
1/8” Backer Panel .5”
1/8” Spacer
1.5”
arrangement and exit locations shall be posted and oriented in a
Evacuation Map
location and manner acceptable to the authority having jurisdiction.
15.75”
View
8.5”
Clear acrylic window
Map Insert Standard size 8.5” x 11” paper folded in half
Insert slot
5.5”
.375”
Basic Layout
Front and Side View
Scale: 1:3
Scale: 1:3
.25”
10.2010
80
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Pictogram Signs/ Restroom Signs [RS] ANSI 117.1 — 1998 Tactile Characters Refer to specifications on Tactile and Braille page. Braille Refer to specifications on Tactile and Braille page. Pictogram Field Pictograms shall have a field 6 inches (150 mm) minimum in height. Characters or Braille shall not be located in the pictogram field. Finish and Contrast Pictograms and their fields shall have a non-glare finish. Pictograms shall contrast with their fields, with either a light pictogram on a dark field or a dark pictogram on a light field. Text Descriptors Where text descriptors for pictograms are required, they shall be located directly below the pictogram field. Finish and Contrast Symbols of accessibility and their backgrounds shall have a non-glare finish. Symbols of accessibility shall contrast with their backgrounds, with either a light symbol on a dark background or a dark symbol on a light background.
MEN
WOMEN
Front View Scale: 1:2
10.2010
81
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Pictogram Signs/ Restroom Signs [RS] 5.25”
.25”
Ecoresin® or frosted polycarbonate
Clear Engraving Stock Printing on surface only, 3.5”
leaving sides clear. Matte
6”
finish in PMS 425. 1/16” thick. View WOMEN
8.75”
Backer Panel 1/8” 18”
Spacer
WOMEN
1/8” .625”
See ANSI 117.1 installation requirements
Clear Engraving Stock
.375” .25”
.75”
Front View
Typical Elevation
Scale: 1:2
Scale: 1:25
10.2010
82
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Tactile Exit Signs [TE] IBC — 2006 5.25”
1011.3 Tactile Exit Signs
.25”
A tactile sign stating EXIT and complying with ICC A117.1 shall be provided adjacent to each door to an area of refuge, an exterior area for assisted rescue, an exit stairway, an exit ramp, an exit passageway and the exit discharge.
NFPA 101 — 2006
Ecoresin® or frosted polycarbonate
7.10.1.3 Exit Door Tactile Signage Tactile signage shall be provided to meet the following criteria, unless otherwise provided in 7.10.1.4: (1) Tactile signage shall be located at each exit door requiring an exit sign.
Clear Engraving Stock
(2) Tactile signage shall read as follows: EXIT.
Printing on surface only,
(3) Tactile signage shall comply
6”
3.5”
leaving sides clear. Matte finish in PMS 425. 1/16” thick.
7.2.2.5.5.8 Emergency Exit Symbol An emergency exit symbol with a luminescent background
8.75”
shall be applied on all doors serving the exit enclosure that swing out from the enclosure in the direction of egress travel. The emergency exit symbol shall also meet the following requirements:
1/8” Backer Panel
(1) The emergency exit symbol shall meet the requirements of NFPA 170, Standard for Fire Safety and Emergency Symbols. (2) The emergency exit symbol applied on the door shall be not
1/8” Spacer
higher than 18 in. (455 mm) above the finished floor.
EXIT
ANSI 117.1 — 1998
EXIT
Pictogram Field: Same as for pictogram signs if pictograms are
.625”
Clear Engraving Stock
.25”
used. Tactile Characters: Refer to specifications on Tactile and Braille page.
.75”
Braille: Refer to specifications on Tactile and Braille page.
Front View
Basic Layout — Front and Side View
Scale: 1:2
Scale: 1:2
10.2010
83
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Area of Refuge [AR] IBC — 2006 1007.11 Instructions 1007.9 Signage
In areas of refuge and exterior areas for assisted rescue,
Signage indicating special accessibility provisions shall be
instructions on the use of the area under emergency
provided as shown:
conditions shall be posted. The instructions shall include all of the following:
1. Each door providing access to an area of refuge from an adjacent floor area shall be identified by a sign stating:
1. Persons able to use the exit stairway do so as soon as
AREA OF REFUGE.
possible, unless they are assisting others.
2. Each door providing access to an exterior area for
2. Information on planned availability of assistance in the
assisted rescue shall be identified by a sign stating:
use of stairs or supervised operation of elevators and how to
EXTERIOR AREA FOR ASSISTED RESCUE.
summon such assistance.
Signage shall comply with the ICC A117.1 requirements
3. Directions for use of the two-way communications
for visual characters and include the International Symbol
system where provided.
7”
.25”
Area of Refuge
Ecoresin® or frosted polycarbonate
Clear Engraving Stock Printing on surface only,
of Accessibility. Where exit sign illumination is required by Section 1011.2, the signs shall be illuminated.
leaving sides clear. Matte
1011.2 Illumination Exit signs shall be internally or externally illuminated.
View
8.75”
finish paint. 1/16” thick.
Additionally, tactile signage complying with ICC A117.1 shall be located at each door to an area of refuge and
Exception: Tactile signs required by Section 1011.3 need
exterior area for assisted rescue in accordance with
not be provided with illumination.
1/8” Backer Panel 1/8” Spacer
Section 1011.3. 1011.3 Tactile Exit Signs 1007.10 Directional Signage
A tactile sign stating EXIT and complying with ICC A117.1
Direction signage indicating the location of the other
shall be provided adjacent to each door to an area of refuge,
means of egress and which are accessible means of
an exterior area for assisted rescue, an exit stairway, an exit
egress shall be provided at the following:
ramp, an exit passageway and the exit discharge.
EXIT
Clear Engraving Stock
1. At exits serving a required accessible space but not providing an approved accessible means of egress. 2. At elevator landings. 3. Within areas of refuge.
International Symbol of Accessibility
Front and Side View Scale: 1:3
10.2010
84
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Two-Way Communication [TC] IBC — 2006 1007.6.3 Two-way Communication Areas of refuge shall be provided with a two-way communication system complying with Sections 1007.8.1 and 1007.8.2.
Clear Engraving Stock Printing on surface only, leaving sides clear. Matte finish paint. 1/16” thick.
1007.8 Two-way Communication A two-way communication system shall be provided at the elevator landing on each accessible floor that is one or more stories above or below the story of exit discharge complying with
.25”
5.25”
Sections 1007.8.1 and 1007.8.2. Exceptions:
In the event of emergency, this phone will provide direct contact to security and emergency personnel.
1. Two-way communication systems are not required at the elevator landing where the two-way communication system is provided within areas of refuge in accordance with Section 1007.6.3. 2. Two-way communication systems are not required on floors provided with exit ramps conforming to the provisions of Section 1010.
3.25”
7”
In the event of emergency, this phone will provide direct contact to security and emergency personnel.
Backer Panel Spacer
View
Emergency Phone
1007.8.1 System Requirements Two-way communication systems shall provide communication between each required location and the fire command center or a central control point location approved by the fire department.
.625”
Emergency Phone
Clear Engraving Stock
.25”
Where the central control point is not constantly attended, a two-way communication system shall have a timed automatic telephone dial-out capability to a monitoring location or 911. The two-way communication system shall include both audible and visible signals.
.75”
Ecoresin® or frosted polycarbonate
1007.8.2 Directions Directions for the use of the two-way communication system, instructions for summoning assistance via the two-way communication system and written identification of the location shall be posted adjacent to the two-way communication system.
Front View
Basic Layout — Front and Side View
Typical Elevation
Scale: 1:3
Scale: 1:3
Scale: 1:25
10.2010
85
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Stairway Level Marker [SL] ANSI 117.1 — 1998 Tactile Characters Refer to specifications on Tactile and Braille page. Braille Refer to specifications on Tactile and Braille page. IBC — 2006 Need specific code references. NFPA 101 — 2006 7.2.2.5.4 Stairway Identification (H) The floor level designation shall also be tactile in accordance with ICC/ANSI A117.1, American National
3.5”
10
3”
Standard for Accessible and Usable Buildings and Facilities.
10
Typical Sign Layout
1 Egress Level Layout
18”
Typical Elevation
10.2010
86
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Occupant Load [OS] IBC — 2006 1004.3 Posting of Occupant Load Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent.
3.5”
Maximum Occupancy
50
3.5”
Maximum Occupancy
100
Front View
Basic Layout
Scale: 1:2
Scale: 1:2
10.2010
87
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Tactile No Exit Signs [NE] NFPA — 2006 7.10.8.3* No Exit
Clear Engraving Stock Printing on surface only, leaving sides clear. Matte finish paint. 1/16” thick.
7.10.8.3.1 Any door, passage, or stairway that is neither an exit nor a
5.25”
way of exit access and that is located or arranged so that
.25”
it is likely to be mistaken for an exit shall be identified by a sign that reads as follows:
NO EXIT
Ecoresin® or frosted polycarbonate
7.10.8.3.2 The NO EXIT sign shall have the word NO in letters 2 in.
6” Pictogram Field
3.5”
(51 mm) high, with a stroke width of 3/8 in. (9.5 mm), and the word EXIT in letters 1 in. (25 mm) high, with the word
View
EXIT below the word NO, unless such sign is an approved existing sign.
10.5”
NO EXIT
NO EXIT
1/8” Backer Panel
1/8” Spacer
2”
Clear Engraving Stock
1”
.25”
.75”
Front View
Basic Layout — Front and Side View
Scale: 1:3
Scale: 1:3
10.2010
88
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Delayed Egress Door Signs [DE] NFPA 101 — 2006 Tactile exit sign required
7.2.1.6.1 Delayed-Egress Locking Systems (5)* A readily visible, durable sign in letters not less than 1 in. (25 mm) high and not less than 1/8 in. (3.2 mm) in stroke
Vinyl adheres to door
width on a contrasting background that reads as follows shall be located on the door leaf adjacent to the release device: PUSH UNTIL ALARM SOUNDS DOOR CAN BE OPENED IN 15 SECONDS Align right (strike side of door)
1” .75”
PUSH UNTIL ALARM SOUNDS DOOR CAN BE OPENED IN 15 SECONDS
EXIT
1”
.125”
7”
.75”
Length of door bar
Front View
Typical Elevation
Scale: 1:5
Scale: 1:25
10.2010
89
Materials & Detail Design
Ohio State University Medical Center Columbus | Ohio
Powered Door Leaf Signs [PD] NFPA 101 — 2006 7.2.1.9* Powered Door Leaf Operation 7.2.1.9.1* General. Where means of egress door leaves are operated by power upon the approach of a person
Tactile exit sign required
or are provided with power-assisted manual operation, the design shall be such that, in the event of power failure, the leaves open manually to allow egress travel
Vinyl adheres to door
or close when necessary to safeguard the means of egress. 7.2.1.9.1.1 The forces required to manually open the door leaves specified in 7.2.1.9.1 shall not exceed those required in 7.2.1.4.5, except that the force required to set the leaf in motion shall not exceed 50 lbs. (222 N). 1”
7.2.1.9.1.2 The door assembly shall be designed and
.75”
installed so that, when a force is applied to the door leaf on the side from which egress is made, it shall be capable of swinging from any position to provide full use of the required width of the opening in which it is
1”
IN EMERGENCY, PUSH TO OPEN
EXITEXIT
.125”
installed. (See 7.2.1.4.) 7.2.1.9.1.3 A readily visible, durable sign in letters not less than 1 in. (25 mm) high on a contrasting
Length of door bar
background that reads as follows shall be located on the egress side of each door opening: IN EMERGENCY, PUSH TO OPEN 7.2.1.9.1.4 Sliding, power-operated door assemblies in an exit access serving an occupant load of fewer than 50 that manually open in the direction of door leaf travel, with forces not exceeding those required in 7.2.1.4.5, shall not be required to have the swing-out feature required by 7.2.1.9.1.2. The required sign shall be in letters not less than 1 in. (25 mm) high on a
Powered Door Leaf Signs
Typical Elevation
contrasting background and shall read as follows: IN EMERGENCY, SLIDE TO OPEN 10.2010
90
Installation
Ohio State University Medical Center Columbus | Ohio
Wall Mounting Scenarios Note: The preferred method of installation is OPTION A. Choice of installation method based on sign location’s circumstances and should be attempted in the order of A,B,C and D until sign is successfully installed.
3”
3”
3”
Large Conference Room
PREFERRED METHOD
1 TYP
Install sign on strike side of door. Allow 3” from obstruction to right edge of sign but no more than 18“ from edge of door frame. 60” from top of sign to finished floor.
Install sign on strike side of door. Allow 3” from edge of door frame and 60” from top of sign to finished floor.
Preferred Installation — Option A Scale 1:30
2 TYP
Installation — Option B Scale 1:30
60”
P1245
Large Conference Room
60”
P1245
Large Conference Room
60”
P1245
Large Conference Room
60”
P1245
Install sign on opposite to strike side of door. Allow 3” from door frame or obstruction to left edge of sign but no more than 18“ from edge of door frame. 60” from top edge of sign to finished floor.
3 TYP
Installation — Option C Scale 1:30
Install sign directly on door if both sides are obstructed. Center sign on door and 60” from top edge of sign to finished floor.
4 TYP
Installation — Option D Scale 1:30 10.2010
91
Installation
Ohio State University Medical Center Columbus | Ohio
Mounting Water Line
Installation Height West Stair C
WOMEN
EXIT EXIT
Stair East
15
P1245
P1245 P1245 Examination Room Laboratory Descriptions Here
12300
In Fire Emergency, Do Not Use Elevator. Use Exit Stairs. Evacuation Map
Critical Care Unit Patient’s Name Doctor’s Name (AM) Doctor’s Name (PM) Nurses’ Names
Re-Entry on L5-10 Down to 1 ST Floor For Exit Discharge
43”
60”
Installation Height
1
Installation Height of Wall Mounted Signs Scale 1:30 10.2010
92
Enhanced Experience: Possible Additions to the Program (TBD)
Ohio State University Medical Center Columbus | Ohio
Adding Value for Building Occupants Station ID
Monitor Display
Vision Screen
Dimensional address at each station with room directory at this station
Loop of all necessary ID and wayfinding content
Translucent glass graphics positioned at eye level for privacy but presented in an artful way
Vinyl Numeral At patient room door
Graphic Art Mural
WEST PATIEN
T BAY “To wish to be well is a part of becoming well.” — Seneca
m I nfo r
Light Box Visual totem offers directory/imagery messages
Wayfinding Icons
a ti o n
(All artwork shown is intended as example only; final designs TBD)
10.2010
Exterior Signage Design Intent, Locations, and Specifications
94
Exterior Signage
Ohio State University Medical Center Columbus | Ohio
Major Building Indentification and Announcers A
B A
B
C
B
The James
James Cancer Center and Solove Research Institute
Cancer Center
Primary Logo Lockup Face lit letters and graphics mounted to structural frame and attached to parapet or suitable surface. Paint structural frame to match other metallic surfaces on building to minimize visibility.
C
The James Cancer Center
James Cancer Center and Solove Research Institute
Building Name Channel letters mounted to structural frame and attached to parapet or suitable surface. Paint structural frame to match other metallic surfaces on building to minimize visibility. Face lit letters with LED.
D
Emergency
Emergency entrance is located at the North facade of building
Emergency Entrance Sign and Cross Graphic This sign marks the entrance to the Emergency unit on the North facade only. Channel letters and cross graphic are both face and back lit for enhanced visiblity. Mount to building canopy.
E
D
Emergency
Arthur G. James Cancer Center & Richard J. Solove Research Institute
E
Arthur G. James Cancer Center & Richard J. Solove Research Institute
Street Level Building Name Stainless steel with satin finish mounted to exterior surface of building visible to pedestrian and vehicular traffic. Use halo illumination to acheive visibility at night. Location TBD.
Note: Diagram only; sizes, locations, and proportion are approximations only.
1
West Facade
2
South Facade
ES
Scale NTS
ES
Scale NTS
10.2010
95
Exterior Signage
Ohio State University Medical Center Columbus | Ohio
Primary Logo Lockup
Logo Graphic Using 3M Panaflex Material and SignComp Bleed Tension Frame
Logo Lockup (Entire Sign)
Logo Graphic
Part number: 2085 and 2095
Logotype (Letters)
2
3
PL
PL
Multiple rows of white LEDs as required for bright and even illumination
Corner key Frame brace Structural frame (horizontal beam)
Frame corner angle
Graphic output on 3M Panaflex translucent film
Attachment fastener
Frame painted to match color of metallic surfaces on building to minimize visibility
Structural frame (horizontal beam)
Backlit channel letters. 1/8" thick clear acrylic faces with 3M Dual Color film on the 2nd surface
Graphic output on 3M Panaflex
approx. 120�
1
Emergency Signage
2
Section View
PL
Scale NTS
PL
Scale NTS
10.2010
96
Exterior Signage
Ohio State University Medical Center Columbus | Ohio
Primary Logo Lockup Logo Graphic / Logotype Using Channeling and Face Lit LED Illumination This portion of logo lockup uses rigid, face lit channeling light box (area outlined in blue stroke)
Frame uses steel angle structure over parapet as required
This portion of logo lockup uses rigid, face lit channeling letters (area outlined in blue stroke)
Galvanized steel angle clips with stainless steel hardware
Multiple rows of white LEDs as required for bright and even illumination
All inside surfaces painted with light enhancement paint (LEP)
Secondary electrical conduit to remote transformers inside the hospital. All secondary electrical to be installed and penetrations waterproofed prior to installation of the insulation, sheathing and internal metal panels
Building
Returns painted to match color of adjacent surfaces on logo
Portion of logo lockup to use flexible 3M Panaflex translucent film and face lit with LED (area outlined in red stroke)
Connect electrical wiring to raceway frame
3
Section View
4
Logo Lockup
PL
Scale NTS
PL
Scale NTS
10.2010
97
Exterior Signage
Ohio State University Medical Center Columbus | Ohio
Primary Logo Lockup
Stainless steel frame providing base structure for logo elements and attaches to building
Daylight sensors or master programmable timing controls activate lighting
Face of the logotype (Medical Center) glows white at night
5
Isometric View
6
Night Illumination
PL
Scale NTS
PL
Scale NTS
10.2010
98
Exterior Signage
Ohio State University Medical Center Columbus | Ohio
Primary Logo Lockup
2
3
PL
PL
This portion of logo lockup uses rigid, face lit channeling light box (area outlined in blue stroke)
This portion of logo lockup uses rigid, face lit channeling letters (area outlined in blue stroke)
Portion of logo lockup to use flexible 3M Panaflex translucent film and face lit with LED (area outlined in red stroke) Backlit channel letters. 1/8" thick clear acrylic faces with 3M Dual Color film on the 2nd surface
Frame painted to match color of metallic surfaces on building to minimize visibility
3
The James PL
Cancer Center
Backlit channel letters. 1/8" thick clear acrylic faces with 3M Dual Color film on the 2nd surface
This portion of logo lockup uses rigid, face lit channeling letters (area outlined in blue stroke)
TBD�
1 PW
Primary Logo on West Facade Scale NTS
2 PW
Components of Signage Scale NTS
10.2010
99
Exterior Signage
Ohio State University Medical Center Columbus | Ohio
Primary Logo Lockup
Stainless steel frame providing base structure for logo elements and attaches to building
Daylight sensors or master programmable timing controls activate lighting
Face of the logotype (Medical Center) glows white at night
Face of the logotype (The James Cancer Center) glows white at night
3 PW
Isometric View Scale NTS
4 PW
Night Illumination Scale NTS
10.2010
100
Exterior Signage
Ohio State University Medical Center Columbus | Ohio
Building Name — Top of Building
approx. 6� Steel angle structure over parapet as required
Galvanized steel angle clips with stainless steel hardware
2 BN
Returns painted to match color of adjacent surfaces on logo
James Cancer Center and Solove Research Institute
Multiple rows of white LEDs as required for bright and even illumination
Fasten steel frame to building Secondary electrical conduit to remote transformers inside the hospital. All secondary electrical to be installed and penetrations waterproofed prior to installation of the insulation, sheathing and internal metal panels
Frame painted to match color of metallic surfaces on building to minimize visibility
All inside surfaces painted with light enhancement paint (LEP)
Building
Multiple rows of white LEDs as required for bright and even illumination
Backlit channel letters. 1/8" thick clear acrylic faces with 3M Dual Color film on the 2nd surface
Connect electrical wiring to raceway frame
1 BN
Logo Lockup
2
Side View
Scale 1:20
BN
Scale NTS
10.2010
101
Exterior Signage
Ohio State University Medical Center Columbus | Ohio
Building Name — Top of Building Stainless steel frame providing base structure for logo elements and attaches to building
Parapet
Daylight sensors or master programmable timing controls activate lighting
Face of the logotype glows white at night
3
Isometric View
4
Night Illumination
BN
Scale NTS
BN
Scale NTS
10.2010
102
Exterior Signage
Ohio State University Medical Center Columbus | Ohio
Emergency Entrance Sign
Building or canopy
Galvanized steel attachment to building 2 EE
2” Acrylic in OSU Red; allow for transmission of light
Emergency
Multiple rows of white LEDs as required for bright and even illumination
5”
Multiple rows of white LEDs on opposite side allowing light spill at rear of sign 1/8" thick clear acrylic faces with 3M Diffuser film on the 2nd surface
20”
1/8" thick clear acrylic faces with 3M Dual Color film on the 2nd surface
All secondary electrical to be installed and penetrations waterproofed prior to installation of the insulation, sheathing and internal metal panels
All inside surfaces painted with light enhancement paint (LEP)
125”
Returns painted to match color of adjacent surfaces on logo Connect electrical wiring to raceway frame
Sign stands off from mounted wall for light spill from LED
Note: Measurements are estimations only.
1 EE
Emergency Signage
2
Section View
Scale 1:20
EE
Scale NTS
10.2010
103
Exterior Signage
Ohio State University Medical Center Columbus | Ohio
Emergency Entrance Sign
Painted metallic side frame in red; weatherproof sealed Daylight sensors or master programmable timing controls activate lighting
Halo illumination in addition to backlit face
White or neutral color temperature LED halo light
3
Isometric View
4
Halo Lighting Illumination
EE
Scale NTS
EE
Scale NTS
10.2010
104
Exterior Signage
Ohio State University Medical Center Columbus | Ohio
Building Name — Street Level
Returns to match stainless steel surface on face 2” 165”
20”
4”
Multiple rows of white LEDs as required for bright and even illumination
Arthur G. James Cancer Center & Richard J. Solove Research Institute
Electrical connection
Stainless steel face
All inside surfaces painted with light enhancement paint (LEP) Stainless steel face with brush, low reflectivity finish
1/8" thick clear acrylic faces with 3M Diffuser film on the 2nd surface
Sign stands off from mounted wall for light spill from LED
Multiple rows of white LEDs as required for bright and even illumination
Building/Mounting wall
1/8" thick clear acrylic faces with 3M Diffuser film on the 2nd surface Electrical connection
Stainless steel face Returns to match stainless steel surface on face
Note: Measurements are estimations only.
1 BB
Logo Lockup
2
Side View
Scale 1:25
BB
Scale NTS
10.2010
105
Exterior Signage
Ohio State University Medical Center Columbus | Ohio
Building Name — Street Level
Daylight sensors or master programmable timing controls activate lighting
Letters defined by halo illumination
Stainless steel face and return with brush, low reflectivity finish
This sign may require external lighting
3
Isometric View
4
Night Illumination
BB
Scale NTS
BB
Scale NTS
10.2010
106
Exterior Signage
Ohio State University Medical Center Columbus | Ohio
Signage Components on North Facade
Channel letters and graphic
2100
WEST 10 TH AVENUE
Physical address in stainless steel dimensional letterforms; pin mount letters to wall individually; not illuminated
Note: This is a diagramatic illustration of signage yet to be located on building facade
1
North Facade (Emergency Entrance)
ES
Scale NTS
10.2010
107
Exterior Signage
Ohio State University Medical Center Columbus | Ohio
Signage Components on South Facade
Horizontal arrangement of building name
2100
WEST 10 AVENUE TH
Physical address in stainless steel dimensional letterforms; pin mount letters to wall individually; not illuminated
Arthur G. James Cancer Center & Richard J. Solove Research Institute
Note: This is a diagramatic illustration of signage yet to be located on building facade
1
South Entry
ES
Scale NTS
10.2010
108
Exterior Signage
Ohio State University Medical Center Columbus | Ohio
Graphics at Building Entry
OSUMC logo
Arthur G. James Cancer Center Wheelchair accessible path
Richard J. Solove Wheelchair Accessible Path
THIS IS A TOBACCO-FREE CAMPUS NOTICE: VIDEO SURVELLIANCE IN USE ON THESE PREMISES.
Restrictions and policy messages
"PURSUANT TO SECTION 30.06, PENAL CODE (TRESPASS BY HOLDER OF A LICENSE TO CARRY A CONCEALED HANDGUN) A PERSON LICENSED UNDER SUBCHAPTER H, CHAPTER 411, GOVERNMENT CODE (CONCEALED HANDGUN LAW), MAY NOT ENTER THIS PROPERTY WITH A CONCEALED HANDGUN."
Research Institute
Building identity and donor recognition
Major donor’s name here Major donor’s name here
OSUMC The James is an equal opportunity employer Call 123-456-7890 for hospital staff assistance and information For translation services, call 123-456-7890 for language assistance
Other building related notices, services, wheelchair request, etc.
Note: This is a diagramatic illustration of signage yet to be located on building facade
1
Vinyl Graphics at Building Entry
VG
Scale NTS
10.2010
109
Exterior Signage
Ohio State University Medical Center Columbus | Ohio
Additional Notes Fabrication Notes on Exterior Signage: (Applicable to all exterior signage) Sign Contrator Submittal Requirements:
Letters: Internally illuminated “face lighted” channel letters with
Electrical: Remote transformers inside UL approved metals boxes
white LED illumination and white translucent acrylic faces with
to be provided by the sign contractor and located inside the
first surface applied 3M Scotchcal Dual Color (black- day/night)
building in the ceiling above removable ceiling panels. The general
film, that appear black in the daytime and illuminate white at
contractor will provide primary electrical service to this point. The
night. Faces to be secured with with aluminum angle face
sign contractor to provide all remote transformers, UL metal
retention. Letters to be fabricated with .090 aluminum backs
boxes, secondary conduit runs, electrical wiring, , installation
and .063 returns painted to match (TBD). All inside surfaces
hardware, disconnect switches, insulators, boots and any
Shop drawings
painted with light enhancement paint (LEP), white. Provide
miscellaneous components, as required for a complete
Fabricate per design drawings
appropriate waterproofing and weep holes on lower surfaces for
installation. All electrical components shall be UL approved and
lettering and logo.
the completed letters shall be inspected and bear UL approved
Face layout drawings for each sign location
labels. The electrical service shall be controlled from a central Logo Graphic: Internally illuminated “face lighted” channel
electrical panel, so photocells will not be required to control the
letters with color translucent acrylic faces with LED illumination.
illumination of the sign.
“Flame” to be fabricated with .090 aluminum backs and .063 returns with aluminum angle face retention. Returns painted to
Installation and Mounting: Coordination of the location of each
match adjacent faces on logo graphics (TBD).
building penetration will be critical and the sign contractor shall install full size rigid templates (not paper). Coordination of all
Field Verification Conditions Prior to shop drawings submittals Prior to installation Drawing Submittals
Sample Submittals Paint Samples Material samples (face acrylic & vinyl) Patterns and Templates Full size mounting templates (rigid) Full size rigid templates applied in place for approval prior to installation
Illumination: Internal illumination to be white LED modules (GE
electrical penetrations and installation of all secondary conduit
Tetra or approved equal). The number of LED module rows to be
runs during construction. This will require multiple site visits prior
determined based on the stroke width of the letter forms and
to final installation to install all secondary electrical penetrations
graphic. Illumination shall be evenly bright on all portions of each
and have these penetrations sealed and weather proofed prior to
letter form with no “hot spots” or “dark areas”. NOTE: Thin
completion of the building wall panels. All installation hardware to
portions of the letter strokes, will require more LEDs at tighter
be non-corrosive for the existing wall conditions. Isolate any
Fabricate per design drawings and approved
spacings than the manufacturers standard recommendations. A
dissimilar metals. Installation to utilize liquid-tight, flexible metal
shop drawings
full size complete prototype letter will be required to be viewed
conduit to transformers. Seal building penetrations as required by
on-site prior to fabrication.
the architect.
Fabrication Samples and Prototypes (1) full sized prototype letter for approval Prototypical installation
10.2010
110
Exterior Signage
Ohio State University Medical Center Columbus | Ohio
Previous Renderings
Previous renderings of exterior signage
10.2010
Wayfinding Schemes Mapped to Typical Floorplates
112
Wayfinding Conventions for CCU
Ohio State University Medical Center Columbus | Ohio
M
M
M
M
Wayfinding Messages M
Map Locations
Restricted Circulation
Wayfinding Into Environment
Wayfinding for Restricted Circulation
Wayfinding Out of Environment
10.2010
113
Public Destinations within CCU
Ohio State University Medical Center Columbus | Ohio
Public Destinations Consult / Meet / Conference
Nurse / Practitioner Stations
Public Toilets
Elevators
Lounge / Waiting
Stairs
10.2010
114
Vertical Circulation Naming for CCU
West Public Elevators Color code : White
West Stair (Stair W)
Ohio State University Medical Center Columbus | Ohio
West Patient Elevators Color code : Gray
Freight Elevators Color code : Gray
Central Stair (Stair C)
West Patient Elevators Color code : Gray
East Public Elevators Color Code : Scarlet
East Stair (Stair E)
10.2010
115
Wayfinding Conventions for ACU
Ohio State University Medical Center Columbus | Ohio
Wayfinding Messages Map Locations
Restricted Circulation
Wayfinding Into Environment
Wayfinding for Restricted Circulation
Wayfinding Out of Environment
10.2010
116
Public Destinations within ACU
Ohio State University Medical Center Columbus | Ohio
Public Destinations Consult / Meet / Conference
Nurse / Practitioner Stations
Public Toilets
Elevators
Lounge / Waiting
Stairs
10.2010
117
Vertical Circulation Naming for ACU
West Stair (Stair W)
West Public Elevators
Ohio State University Medical Center Columbus | Ohio
West Patient Elevators
Freight Elevators
East Stair (Stair E)
10.2010
H O K V I S U A L C O M M U N I C AT I O N S IMAGE AND IDENTITY PLANNING INFORMATION MEDIA WAYFINDING AND ARCHITECTURAL GRAPHICS DISPLAY ENVIRONMENTS
HOK Visual Communications can strategically plan and design the appropriate vehicle to convey your message, package your information, position your image, or promote your product. Our client experience is broad in scope and international in reach. We offer deep, knowledgeable expertise in communicating about all aspects of the built environment. We seek functional, aesthetic, and economic solutions that are flexible and durable and we fully understand the business implications of good design. 2800 POST OAK BOULEVARD | SUITE 3700 | HOUSTON | TEXAS | 77056 | USA
+1 713 407 7700 | hok.com