EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 128
Page
a max. [m/s2]
v max. [m/s] gliding
v max. [m/s] unsupported
Oil-resistant
Approvals and standards
Temperature, moved from/to [°C]
Min. bending radius, moved [factor x d]
Shield
Jacket
chainflex® cable
chainflex type
Torsion resistant
®
Bus cables
Bus cables
Selection chart for chainflex® bus cables
130
CFBUS.PVC
PVC
✔
12,5
-5/ +70
✔
2
30
134
CFBUS.PUR
PUR
✔
12,5
-20/ +70
✔
2
30
136
CFBUS
TPE
✔ 10-12,5
-35/ +70
✔
10
6
100
138
CF11.LC
TPE
✔
10
-35/ +70
✔
10
6
100
144
CF11.LC.D
TPE
✔
10
-35/ +70
✔
10
6
100
146
CF14 CAT5
TPE
✔
12,5
-35/ +70
✔
10
6
100
148
129
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:56 Seite 130
chainflex® Bus cable
Profibus
150 Ohm
CFBUS.PVC.001 CFBUS.PUR.001 CFBUS.001 CF11.02.01.02.PBA.LC.D CFROBOT8.001 CFBUS.002 CF11.02.02.15.04.PBA.LC.D CFBUS.003 CF11.02.02.07.03.PBA.LC.D CF11.02.02.02.PBA.LC
(2 x 0,25)C (2 x 0,25)C (2 x 0,25)C (2 x 0,25)C (2 x 0,35)C 4 x 1,5 + (2 x 0,25)C 4 x 1,5 + (2 x 0,25)C 3 x 0,75+(2 x 0,25)C 3 x 0,75+(2 x 0,25)C (2 x (2 x 0,25))C
Interbus
100 Ohm
CFBUS.010 CF11.02.03.02.IB-S CFBUS.011 CF11.02.03.02.10.03.IB-S
(3 x (2 x 0,25))C (3 x (2 x 0,25))C (3 x 2 x 0,25 + 3 x 1,0)C (3 x 2 x 0,25 + 3 x 1,0)C
CAN-Bus
120 Ohm
CFBUS.PVC.021 CFBUS.PUR.021 CFBUS.021 CF11.05.01.02.LC CF11.05.01.02.LC.D CFBUS.020 CF11.02.02.02.LC.D CFBUS.PVC.022 CFBUS.PUR.022 CFBUS.022 CF11.05.02.02.LC CFROBOT8.022
(2 x 0,5)C (2 x 0,5)C (2 x 0,5)C (2 x 0,5)C (2 x 0,5)C (2 x (2 x 0,25)C (2 x (2 x 0,25)C (2 x (2 x 0,5))C (2 x (2 x 0,5))C (2 x (2 x 0,5))C (2 x (2 x 0,5))C (2 x (2 x 0,5))C
Device-Net
120 Ohm
CFBUS.030 CFBUS.031
((2 x AWG 24)C + 2 x AWG 22)C ((2 x AWG 18)C + 2 x AWG 15)C
Temperature, moved from/to [°C]
Class
12,5 x d 12,5 x d 10 x d 10 x d 10 x d 10 x d 10 x d 10 x d 10 x d 10 x d
PVC PUR TPE TPE PUR TPE TPE TPE TPE TPE
- 5 °C to +70 °C* - 20 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 20 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C
Class 4.1.2 Class 4.1.3 Class 6.4.4 Class 6.4.4 Class 6.1.3 Class 6.4.4 Class 6.4.4 Class 6.4.4 Class 6.4.4 Class 6.4.4
✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
10 x d 10 x d 10 x d 10 x d
TPE TPE TPE TPE
- 35 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C
Class 6.4.4 Class 6.4.4 Class 6.4.4 Class 6.4.4
✔ ✔ ✔ ✔
12,5 x d 12,5 x d 10 x d 10 x d 10 x d 10 x d 10 x d 12,5 x d 12,5 x d 10 x d 10 x d 10 x d
PVC PUR TPE TPE TPE TPE TPE PVC PUR TPE TPE PUR
- 5 °C to +70 °C* - 20 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 5 °C to +70 °C* - 20 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 20 °C to +70 °C
Class 4.1.2 Class 4.1.3 Class 6.4.4 Class 6.4.4 Class 6.4.4 Class 6.4.4 Class 6.4.4 Class 4.1.2 Class 4.1.3 Class 6.4.4 Class 6.4.4 Class 6.1.3
✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
10 x d 10 x d
TPE TPE
- 35 °C to +70 °C - 35 °C to +70 °C
Class 6.4.4 Class 6.4.4
✔ ✔
✔ ✔
✔ ✔ ✔
✔ ✔
✔ ✔ ✔ ✔ ✔ ✔
Approvals and standards
Page
Gliding
Number of cores and conductor Min. bending Jacket nominal cross section [mm2] radius, moved
Unsupported
Bus system/ chainflex® type
Halogen-free
Selection chainflex® bus cables UV-resistant
chainflex® Bus cable
✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ twisted ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
134 136 138 146 244 138 146 138 146 144
✔ ✔ ✔ ✔
✔ ✔ ✔ ✔
138 144 138 144
✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ twisted
134 136 138 144 146 138 146 134 136 138 144 244
✔ ✔
138 138
✔ ✔
* -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2, +5 °C to +70 °C for use in energy chains® with > 50.000 cycles
More bus systems
130
Page 132
131
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:56 Seite 132
chainflex® Bus cable
Gliding
✔
✔
138
✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ twisted
138 148 138 148 138 148 134 136 138 138 244
✔
✔
✔
138
Class 6.4.4
✔
✔
✔
138
- 5 °C to +70 °C* - 20 °C to +70 °C - 35 °C to +70 °C -20 °C to +70 °C
Class 4.1.2 Class 4.1.3 Class 6.4.4 Class 6.1.3
✔ ✔ ✔ ✔
✔ ✔ ✔ twisted
✔ ✔ ✔
134 136 138 244
TPE TPE
- 35 °C to +70 °C - 35 °C to +70 °C
Class 6.4.4 Class 6.4.4
✔ ✔
✔ ✔
✔ ✔
138 138
TPE
- 35 °C to +70 °C
Class 6.4.4
✔
✔
✔
138
Bus system/ chainflex® type
Number of cores and conductor Min. bending Jacket nominal cross section [mm2] radius, moved
CC-Link
110 Ohm
CFBUS.035
(3 x AWG 20)C
Ethernet CAT5/GigE
100 Ohm
CFBUS.040 CF14.02.02.02.CAT5 CFBUS.041 CF14.02.04.02.CAT5 CFBUS.042 CF14.02.05.02.CAT5 CFBUS.PVC.045 CFBUS.PUR.045 CFBUS.044 CFBUS.045 CFROBOT8.045
(2 x (2 x 0,25))C (2 x (2 x 0,25))C (4 x (2 x 0,25))C (4 x (2 x 0,25))C (5 x (2 x 0,25))C (5 x (2 x 0,25))C (4 x (2 x 0,15))C (4 x (2 x 0,15))C (4 x (2 x 0,15))C (4 x (2 x 0,15))C (4 x (2 x 0,15))C
Ethernet CAT6
100 Ohm
CFBUS.050
(4 x (2 x 0,14)C)C
FireWire
100 Ohm
CFBUS.055
(2 x (2 x 0,15)C+2 x (0,34)C)
Profinet
100 Ohm
CFBUS.PVC.060 CFBUS.PUR.060 CFBUS.060 CFROBOT8.060
(4 x 0,38)C (4 x 0,38)C (4 x 0,38)C (2 x (2 x 0,34))C
USB
90 Ohm
CFBUS.065 CFBUS.066
(2 x 0,5+1 x (2 x 0,08))C (2 x 0,5+1 x (2 x 0,24))C
DVI
100 Ohm
CFBUS.070
(4 x (2 x 0,08+2 x 0,08 + 3 x 0,08))C
Temperature, moved from/to [°C]
Class
10 x d
TPE
- 35 °C to +70 °C
Class 6.4.4
✔
12,5 x d 12,5 x d 12,5 x d 12,5 x d 12,5 x d 12,5 x d 12,5 x d 12,5 x d 12,5 x d 12,5 x d 10 x d
TPE TPE TPE TPE TPE TPE PVC PUR TPE TPE PUR
- 35 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 5 °C to +70 °C* - 20 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 20 °C to +70 °C
Class 6.4.4 Class 6.3.4 Class 6.4.4 Class 6.3.4 Class 6.4.4 Class 6.3.4 Class 4.1.2 Class 4.1.3 Class 6.4.4 Class 6.4.4 Class 6.1.3
✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
12,5 x d
TPE
- 35 °C to +70 °C
Class 6.4.4
12,5 x d
TPE
- 35 °C to +70 °C
12,5 x d 12,5 x d 12,5 x d 10 x d
PVC PUR TPE PUR
12,5 x d 12,5 x d 12,5 x d
Halogen-free
Unsupported
Selection chainflex® bus cables UV-resistant
chainflex® Bus cable
✔ ✔ ✔ ✔
✔
Approvals and standards
Page
* -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2, +5 °C to +70 °C for use in energy chains® with > 50.000 cycles
More bus systems
132
Page 130
133
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:56 Seite 134
CFBUS.PVC PVC 12,5 x d
PVC Bus cable CFBUS.PVC ● ● ● ● ●
Class 4.1.2 (4 medium load requirements
for medium load requirements PVC outer jacket shielded oil-resistant flame-retardant
Conductor Core insulation
Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). According to bus specification.
Core stranding
According to bus specification.
Core identification
According to bus specification Schedule Delivery Program Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in energy chains® (following DIN VDE 0281 Part 13). Colour: Red lilac (similar to RAL 4001) -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2, +5 °C to +70 °C for use in energy chains® with > 50.000 cycles, minimum bending radius 12,5 x d -20 °C to +70 °C, minimum bending radius 7,5 x d
Overall shield Outer jacket
T/R moved
T/R fixed v max. freely suspended a max.
2 m/s
Travel distance
Freely suspended travel distances, Class 1
UV-resistant
Medium
Nominal voltage
30 V
Testing voltage
500 V
Oil
Oil-resistant (following DIN EN 50363-4-1), Class 2.
Flame-retardant
According to IEC 60332-1-2, CEI 20-35, FT1, VW-1
Silicon-free
Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Style 1598 and 2571, 30 V, 80 °C
UL/CSA
30 m/s2
NFPA
Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)
CEI
Following CEI 20-35
CE
Following 2006/95/EG
Lead free
Following 2011/55/EU (RoHS-II)
Typical application area ● ● ● ● ●
for medium load requirements light oil influence preferably indoor applications, but also outdoor ones at temperatures > 5 °C especially for freely suspended travel distances Bus connection cable for storage and retrieval units for high-bay warehouses, machining units/machine tools, handling, indoor cranes
Delivery program Part No.
Image exemplary.
Number of cores and conductor nominal cross section [mm2]
Profibus CFBUS.PVC.001 CAN-Bus CFBUS.PVC.021 CFBUS.PVC.022(2) Ethernet/CAT5/GigE CFBUS.PVC.045 Profinet CFBUS.PVC.060(16)
External diameter approx. [mm]
Copper index [kg/km]
Weight [kg/km]
(2x0,25)C
8,0
22
71
(2x0,5)C (2x(2x0,5))C
8,5 8,5
27 38
81 94
(4x(2x0,15))C
7,0
34
62
(4 x 0,38)C
7,0
38
67
®
The chainflex types marked with (2) are cables designed as a star-quad. (16) Colour outer jacket: Yellow green (similar to RAL 6018) Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core
Delivery program Characteristic Part No. wave impedance approx. [Ω] Profibus CFBUS.PVC.001 150 CAN-Bus CFBUS.PVC.021 120 CFBUS.PVC.022 120 Ethernet/CAT5/GigE CFBUS.PVC.045 100 Profinet CFBUS.PVC.060
eplan download, configurator
1 freely suspended 2 oil-resistant)
CFBUS.PVC PVC 12,5 x d
100
Number of cores Colour code and conductor nominal cross section [mm2] (2x0,25)C red, green (2x0,5)C (2x(2x0,5))C (4x(2x0,15))C
(4x0,38)C
white, brown white, green, brown, yellow (star-quad stranding) white-blue/blue, white-orange/orange, white-green/green, white-brown/brown white, yellow, blue, orange (star-quad stranding)
www.igus.eu/en/CFBUSPVC
950 types from stock no cutting costs ... (for up to 10 cuts of the same type)
... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu
135
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:56 Seite 136
CFBUS.PUR PUR 12,5 x d
PUR Bus cable CFBUS.PUR ● ● ● ● ● ● ● ●
Class 4.1.3 (4 medium load requirements
for medium load requirements PUR outer jacket shielded oil-resistant and coolant-resistant notch-resistant PVC-free/halogen-free flame-retardant hydrolysis-resistant and microbe-resistant Conductor
UL/CSA
Style 1598 and 20236, 30 V, 80 °C
NFPA
Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)
CEI
Following CEI 20-35
CE
Following 2006/95/EG
DESINA
According to VDW, DESINA standardisation
Lead free
Following 2011/55/EU (RoHS-II)
Core insulation
Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). According to bus specification.
Core stranding
According to bus specification.
Typical application area
Core identification
● ● ● ● ●
T/R moved
According to bus specification Schedule Delivery Program Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Red lilac (similar to RAL 4001) -20 °C to +70 °C, minimum bending radius 12,5 x d
T/R fixed
-40 °C to +70 °C, minimum bending radius 7,5 x d
v max. freely suspended a max.
2 m/s
Travel distance
Freely suspended travel distances, Class 1
UV-resistant
Medium
Profibus CFBUS.PUR.001 CAN-Bus CFBUS.PUR.021 CFBUS.PUR.022(2) Ethernet/CAT5/GigE CFBUS.PUR.045 Profinet CFBUS.PUR.060(16)
Nominal voltage
30 V
Testing voltage
500 V
Oil
Oil-resistant (following DIN EN 50363-10-2), Class 3.
Offshore
MUD-resistant following NEK 606 – status 2009.
Flame-retardant
According to IEC 60332-1-2, CEI 20-35, FT1, VW-1
Silicon-free
Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.
Overall shield Outer jacket
Halogen-free
30 m/s2
for medium load requirements almost unlimited resistance to oil indoor and outdoor applications without direct sun radiation especially for freely suspended travel distances Bus connection cable for machining units/machine tools, low-temperature applications
Delivery program Part No.
Image exemplary.
Number of cores and conductor nominal cross section [mm2]
External diameter approx. [mm]
Copper index [kg/km]
Weight [kg/km]
(2x0,25)C
8,0
22
67
(2x0,5)C (2x(2x0,5))C
8,5 8,5
27 38
76 89
(4x(2x0,15))C
7,0
34
62
(4 x 0,38)C
7,0
38
64
The chainflex® types marked with (2) are cables designed as a star-quad. (16) Colour outer jacket: Yellow green (similar to RAL 6018) Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core
Delivery program Characteristic Part No. wave impedance approx. [Ω] Profibus CFBUS.PUR.001 150 CAN-Bus CFBUS.PUR.021 120 CFBUS.PUR.022 120 Ethernet/CAT5/GigE CFBUS.PUR.045 100 Profinet CFBUS.PUR.060
eplan download, configurator
1 freely suspended 3 oil-resistant)
CFBUS.PUR PUR 12,5 x d
100
Number of cores Colour code and conductor nominal cross section [mm2] (2x0,25)C red, green (2x0,5)C (2x(2x0,5))C (4x(2x0,15))C
(4x0,38)C
white, brown white, green, brown, yellow (star-quad stranding) white-blue/blue, white-orange/orange, white-green/green, white-brown/brown white, yellow, blue, orange (star-quad stranding)
www.igus.eu/en/CFBUSPUR
950 types from stock no cutting costs ... (for up to 10 cuts of the same type)
... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu
137
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:56 Seite 138
CFBUS TPE 10-12,5 x d
TPE Bus cable CFBUS ● ● ● ● ● ● ●
Class 6.4.4 (6 maximum load requirements
for maximum load requirements TPE outer jacket shielded oil-resistant 300 V UL for Ethernet biooil-resistant flame-retardant hydrolysis-resistant and microbe-resistant
NEW!
Conductor Core insulation
Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). According to bus specification.
Core stranding
According to bus specification.
Core identification
According to bus specification Schedule Delivery Program TPE mixture adapted to suit the requirements in energy chains®.
Inner jacket Overall shield
T/R moved
Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Red lilac (similar to RAL 4001) -35 °C to +70 °C, minimum bending radius 10-12,5 x d
T/R fixed
-40 °C to +70 °C, minimum bending radius 5 x d
Outer jacket
4 travel distance up to 400 m 4 oil-resistant)
CFBUS TPE 10-12,5 x d
UL/CSA
Style 1589 and 21371, 30 V, 80 °C
NFPA
Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)
CEI
Following CEI 20-35
CE
Following 2006/95/EG
DESINA
According to VDW, DESINA standardisation
Lead free
Following 2011/55/EU (RoHS-II)
Clean room
According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, tested by IPA according to standard 14644-1
Typical application area ● ● ● ● ●
for maximum load requirements almost unlimited resistance to oil, also with bio-oils indoor and outdoor applications without direct sun radiation especially for freely suspended and gliding travel distances up to 400 m Bus connection cable for storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, indoor cranes, low-temperature applications
Test data
Page 34 or www.igus.eu/en/test3
v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2 Travel distance UV-resistant
Freely suspended and gliding travel distances up to 400 m, Class 4 Medium
Nominal voltage
30 V
Testing voltage
500 V
Oil
Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. According to IEC 60332-1-2, CEI 20-35, FT1, VW-1
Flame-retardant
Image exemplary.
Silicon-free
Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).
eplan download, configurator
www.igus.eu/en/CFBUS
950 types from stock no cutting costs ... (for up to 10 cuts of the same type)
FireWire cable for moving energy supplies in digital camera technology.
... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu
139
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:56 Seite 140
CFBUS TPE 10-12,5 x d
TPE Bus cable CFBUS
Class 6.4.4 (6 maximum load requirements
4 travel distance up to 400 m 4 oil-resistant)
CFBUS TPE 10-12,5 x d
Image exemplary.
Delivery program Part No.
Number of cores and External conductor nominal cross diameter 2 section [mm ] approx. [mm] Profibus (minimum bending radius 10 x d) Style 1589/21371, 30 V, 80°C CFBUS.001 (2x0,25)C 8,5 CFBUS.002 4x1,5+(2x0,25)C 12,5
Copper index [kg/km]
Weight [kg/km]
23 96
70 175
11,0
58
121
Interbus (minimum bending radius 10 x d) Style 1589/21371, 30 V, 80°C CFBUS.010 (3x(2x0,25))C 8,5 CFBUS.011 (3x2x0,25+3x1,0)C 10,0
42 74
83 135
CFBUS.003
3x0,75+(2x0,25)C
CAN-BUS/Fieldbus (minimum bending radius 10 x d) Style 1589/21371, 30 V, 80°C CFBUS.020(2) (2x(2x0,25))C 6,5 33 CFBUS.021 (2x0,5)C 8,5 36 (2) CFBUS.022 (2x(2x0,5))C 8,5 45 DeviceNet (minimum bending radius 10 x d) CFBUS.030(4) Drop ((2xAWG24)C+2xAWG22)C 7,5 33 CFBUS.031
Trunk ((2xAWG18)C+2xAWG15)C
11,5
96
66 77 83 65 110
CC-Link (minimum bending radius 10 x d) Style 1589/21371, 30 V, 80°C CFBUS.035 (3xAWG20)C 8,5 44 90 New* Ethernet/CAT5/GigE (minimum bending radius 12,5 x d) Style 10138/21235, 300 V, 80 °C – starting from manufacturing date 4/2012 CFBUS.040(2) (2x(2x0,25))C 7,0 33 43 CFBUS.041 (4x(2x0,25))C 10,0 46 101 CFBUS.042(1) (5x(2x0,25))C 10,5 53 106 CFBUS.044 (4x(2x0,15))C 8,0 35 79 CFBUS.045 (4x(2x0,15))C 8,0 35 79 Ethernet/CAT6 (minimum bending radius 12,5 x d) Style 1589/21371, 30 V, 80°C CFBUS.050 (4x(2x0,14)C)C 10,0 77
131
(1) Delivery time upon inquiry. (4) manufactured without inner jacket The chainflex® types marked with (2) are cables designed as a star-quad. Other types available on request. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalog.
Other types
Page 142
eplan download, configurator
www.igus.eu/en/CFBUS
950 types from stock no cutting costs ... 140
(for up to 10 cuts of the same type)
Delivery program Characteristic Core group Colour code Part No. wave impedance approx. [Ω] Profibus CFBUS.001 150 (2x0,25)C red, green CFBUS.002 150 4x1,5+ black with white numbers (2x0,25)C red/green CFBUS.003 150 3x0,75+ black, blue, green-yellow (2x0,25)C red/green Interbus CFBUS.010 100 (3x(2x0,25))C white/brown, green/yellow, gray/pink CFBUS.011 100 (3x1,0+ red, blue, green-yellow 3x(2x0,25))C white/brown, green/yellow, gray/pink CAN-BUS/Fieldbus CFBUS.020 120 (2x(2x0,25))C white, green, brown, yellow (star-quad stranding) CFBUS.021 120 (2x0,5)C white, brown CFBUS.022 120 (2x(2x0,5))C white, green, brown, yellow (star-quad stranding) DeviceNet CFBUS.030 Drop 120 (1x2xAWG24)+ white/blue (1x2xAWG22)C red/black CFBUS.031 Trunk 120 (1x2xAWG18)+ white/blue (1x2xAWG15)C red/black CC-Link CFBUS.035 110 (3xAWG20)C white, yellow, blue Ethernet/CAT5/GigE CFBUS.040 100 (2x(2x0,25))C white, green, brown, yellow (star-quad stranding) CFBUS.041 100 (4x(2x0,25))C white/brown, green/yellow, gray/pink, blue/red CFBUS.042 100 (5x(2x0,25))C white/brown, green/yellow, gray/pink, blue/red, black/violet CFBUS.044 100 (4x(2x0,15))C white/brown, green/yellow, gray/pink, blue/red CFBUS.045 100 (4x(2x0,15))C white-blue/blue, white-orange/orange, white-green/green, white-brown/brown Ethernet/CAT6 CFBUS.050 100 (4x(2x0,14)C)C white, blue, white, orange, white, green, white, brown
Technical note The USB, FireWire and GigE-cables shown on these pages were developed for the ambitious industrial usage in e-chains®. High proofness to oil and lubricants is as secured as protection against electromagnetical interferences. This high mechanical service life was reached with the usage of high quality materials which even care for the electrical safeness. In single cases communication errors can occur, if very different hardware and software is combined. We recommend tests with all components and the cables before starting serial production, to get the proove for a perfect running system. Of course we support you with the details of these electrical tests. Just give us a call!
... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu
141
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:56 Seite 142
CFBUS TPE 10-12,5 x d
TPE Bus cable CFBUS
Class 6.4.4 (6 maximum load requirements
4 travel distance up to 400 m 4 oil-resistant)
CFBUS TPE 10-12,5 x d
Image exemplary.
Delivery program Part No.
Number of cores and External conductor nominal cross diameter 2 section [mm ] approx. [mm] FireWire (minimum bending radius 12,5 x d) Style 1589/21371, 30 V, 80°C CFBUS.055 (2x(2x0,15)C+2x(0,34)C) 7,5
Copper index [kg/km]
Weight [kg/km]
42
81
Profinet (minimum bending radius 12,5 x d) Style 10138/21235, 300 V, 80°C – starting from manufacturing date 4/2012 CFBUS.060(16) (4x0,38)C 7,5 37 71 USB (minimum bending radius 12,5 x d) Style 1589/21371, 30 V, 80°C CFBUS.065 (2x0,5+1x(2x0,08))C 5,0 26 45 CFBUS.066
(2x0,5+1x(2x0,24))C
6,0
32
56
DVI (minimum bending radius 12,5 x d) Style 1589/21371, 30 V, 80°C CFBUS.070 (4x(2x0,08)C+1x2x0,08+3x0,08)C 9
33
92
(16) Colour outer jacket: Yellow green (similar to RAL 6018) Other types available on request. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core
Delivery program Characteristic Core group Colour code Part No. wave impedance approx. [Ω] FireWire CFBUS.055 100 2x(2x0,15)C+ orange/blue, green/red 2x(0,34)C black, white Profinet CFBUS.060 100 (4x0,38)C white, yellow, blue, orange (star-quad stranding) USB CFBUS.065 90 2x0,5 red, black 2x0,08 white/green CFBUS.066 90 2x0,5 red, black 2x0,24 white/green DVI CFBUS.070 100 (4x(2x0,08+ 4 x white/yellow with elementjacket in blue, black, white, red 2x0,08+3x0,08))C white/brown, green, yellow, gray
Order example: CFBUS.060 – in your desired length (0,5 m steps) CFBUS chainflex series .060 Code BUS-type ®
Other types
Page 140
Please use www.chainflex.eu/en/CFBUS for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.
Technical note
eplan download, configurator
www.igus.eu/en/CFBUS
950 types from stock no cutting costs ... 142
(for up to 10 cuts of the same type)
The USB, FireWire and GigE-cables shown on these pages were developed for the ambitious industrial usage in e-chains®. High proofness to oil and lubricants is as secured as protection against electromagnetical interferences. This high mechanical service life was reached with the usage of high quality materials which even care for the electrical safeness. In single cases communication errors can occur, if very different hardware and software is combined. We recommend tests with all components and the cables before starting serial production, to get the proove for a perfect running system. Of course we support you with the details of these electrical tests. Just give us a call!
... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu
143
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:56 Seite 144
CF11.LC TPE 10 x d
TPE Bus cable CF11.LC (low capacitance) ● ● ● ● ● ● ● ●
Class 6.4.4 (6 maximum load requirements
for maximum load requirements TPE outer jacket shielded oil-resistant biooil-resistant PVC-free/halogen-free UV-resistant hydrolysis-resistant and microbe-resistant
4 travel distance up to 400 m 4 oil-resistant)
CF11.LC TPE 10 x d
CE
Following 2006/95/EG
Lead free
Following 2011/55/EU (RoHS-II)
Clean room
According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1
Typical application area Conductor Core insulation
Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). According to bus specification.
Core stranding
According to bus specification.
Core identification
According to bus specification Schedule Delivery Program TPE mixture adapted to suit the requirements in energy chains®.
Inner jacket Overall shield
T/R moved
Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Steel blue (similar to RAL 5011) -35 °C to +70 °C, minimum bending radius 10 x d
T/R fixed
-40 °C to +70 °C, minimum bending radius 5 x d
Outer jacket
● ● ● ● ●
for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m Bus connection cable for storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, outdoor cranes, low-temperature applications
Delivery program Part No. Interbus CF11.02.03.02.IB-S CF11.02.03.02.10.03.IB-S CAN-Bus CF11.05.01.02.LC CF11.05.02.02.LC(2) Profibus CF11.02.02.02.PBA.LC(2)
Number of cores and conductor nominal cross section [mm2] (3x(2x0,25))C (3x2x0,25+3x1,0)C
External diameter approx. [mm] 8,5 10,0
Copper index [kg/km] 42 74
Weight [kg/km]
(2x0,5)C (2x(2x0,5))C
8,5 8,5
36 45
77 83
(2x(2x0,25))C
8,5
33
80
83 135
®
The chainflex types marked with (2) are cables designed as a star-quad. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core
v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2 Travel distance UV-resistant
Freely suspended and gliding travel distances up to 400 m, Class 4 High
Nominal voltage
30 V
Testing voltage
500 V
Oil
Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.
Silicon-free Halogen-free
Delivery program Characteristic Number of cores and Part No. wave impedance conductor nominal Interbus approx. [Ω] cross section [mm2] CF11.02.03.02.IB-S 100 (3x(2x0,25))C CF11.02.03.02.10.03.IB-S 100 (3x2x0,25+ 3x1,0)C CAN-Bus CF11.05.01.02.LC 120 (2x0,5)C CF11.05.02.02.LC 120 (2x(2x0,5))C Profibus CF11.02.02.02.PBA.LC 150 (2x(2x0,25))C
Colour code
white/brown, green/yellow, gray/pink white/brown, green/yellow, gray/pink red, blue, green-yellow white, brown white, green, brown, yellow (star-quad stranding) green, yellow , red, brown (star-quad stranding)
Order example: CF11.02.03.02.IB-S – in your desired length (0,5 m steps) CF11.LC chainflex series .02 Code nominal cross section .03 Number of pairs .02 Identification pairs .IB-S Special identification ®
Image exemplary.
Please use www.chainflex.eu/en/CF11LC for your online order.
eplan download, configurator
www.igus.eu/en/CF11LC
950 types from stock no cutting costs ... (for up to 10 cuts of the same type)
Delivery time 24h or today. Delivery time means time until shipping of goods.
... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu
145
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:56 Seite 146
CF11.LC.D TPE 10 x d
TPE Bus cable CF11.LC.D (low capacitance) ● ● ● ● ● ● ●
Class 6.4.4 (6 maximum load requirements
for maximum load requirements TPE outer jacket shielded PVC-free/halogen-free oil-resistant biooil-resistant hydrolysis-resistant and microbe-resistant
Conductor Core insulation
Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). According to bus specification.
Core stranding
According to bus specification.
Core identification
According to bus specification Schedule Delivery Program TPE mixture adapted to suit the requirements in energy chains®.
Inner jacket Overall shield Outer jacket
T/R moved T/R fixed
Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Red lilac (similar to RAL 4001) -35 °C to +70 °C, minimum bending radius 10 x d -40 °C to +70 °C, minimum bending radius 5 x d
UV-resistant
Freely suspended and gliding travel distances up to 400 m, Class 4 Medium
Nominal voltage
30 V
Testing voltage
500 V
Oil
Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.
Silicon-free Halogen-free
CE
Following 2006/95/EG
DESINA
According to VDW, DESINA standardisation
Lead free
Following 2011/55/EU (RoHS-II)
Clean room
According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1
Typical application area ● ● ● ● ●
for maximum load requirements almost unlimited resistance to oil, also with bio-oils indoor and outdoor applications without direct sun radiation especially for freely suspended and gliding travel distances up to 400 m Bus connection cable for storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, indoor cranes, low-temperature applications
Delivery program Number of cores and Part No. conductor nominal Profibus cross section [mm2] CF11.02.01.02.PBA.LC.D (2x0,25)C CF11.02.02.07.03.PBA.LC.D 3x0,75+(2x0,25)C CF11.02.02.15.04.PBA.LC.D 4x1,5+(2x0,25)C CAN-Bus CF11.02.02.02.LC.D(2) (2x(2x0,25))C CF11.05.01.02.LC.D (2x0,5)C
External diameter approx. [mm] 8,5 11,0 12,5
Copper index [kg/km] 23 58 96
Weight [kg/km]
6,5 8,5
33 36
66 77
70 121 175
The chainflex® types marked with (2) are cables designed as a star-quad. Other types available on request. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core
v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2 Travel distance
4 travel distance up to 400 m 4 oil-resistant)
CF11.LC.D TPE 10 x d
Delivery program Characteristic Number of cores and Part No. wave impedance conductor nominal Profibus approx. [Ω] cross section [mm2] CF11.02.01.02.PBA.LC.D 150 (2x0,25)C CF11.02.02.07.03.PBA.LC.D 150 3x0,75+ (2x0,25)C CF11.02.02.15.04.PBA.LC.D 150 4x1,5+ (2x0,25)C CAN-Bus CF11.02.02.02.LC.D 120 (2x(2x0,25))C CF11.05.01.02.LC.D 120 (2x0,5)C
Colour code red/green black, blue, green-yellow red/green black with white numbers red/green white, green, brown, yellow (star-quad stranding) white/brown
Order example: CF11.02.01.02.PBA.LC.D – in your desired length (0,5 m steps) CF11.LC.D chainflex series .02 Code nominal cross section .01 Number of pairs .02 Identification pairs .PBA.LC.D Special identification ®
Image exemplary.
Please use www.chainflex.eu/en/CF11LCD for your online order. eplan download, configurator
www.igus.eu/en/CF11LCD
950 types from stock no cutting costs ... (for up to 10 cuts of the same type)
Delivery time 24h or today. Delivery time means time until shipping of goods.
... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu
147
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:56 Seite 148
CF14 CAT5 TPE 12,5 x d
TPE Bus cable CF14CAT5 ● ● ● ● ● ● ●
Class 6.3.4 (6 maximum load requirements
Ethernet special cable for heavy-duty use TPE outer jacket oil-resistant biooil-resistant PVC-free/halogen-free UV-resistant hydrolysis-resistant and microbe-resistant
Conductor
CE
Following 2006/95/EG
DESINA
According to VDW, DESINA standardisation
Lead free
Following 2011/55/EU (RoHS-II)
Clean room
According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1
19-wire conductor consisting of bare copper wires in especially bending-resistant braiding quality. Special PP-isolating mixture.
Typical application area
Core identification
2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Colour code in accordance with DIN 47100
● ● ● ● ●
Inner jacket
TPE mixture adapted to suit the requirements in energy chains®.
Overall shield
T/R moved
Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Red lilac (similar to RAL 4001) -35 °C to +70 °C, minimum bending radius 12,5 x d
T/R fixed
-40 °C to +70 °C, minimum bending radius 7,5 x d
Core insulation Core stranding
Outer jacket
v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2 Travel distance UV-resistant
Freely suspended and gliding travel distances up to 100 m, Class 3 Medium
Nominal voltage
30 V
Testing voltage
500 V
Oil
Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.
Silicon-free Halogen-free
3 travel distance up to 100 m 4 oil-resistant)
CF14 CAT5 TPE 12,5 x d
for maximum load requirements almost unlimited resistance to oil, also with bio-oils indoor and outdoor applications without direct sun radiation especially for freely suspended and gliding travel distances up to 100 m Ethernet cable for Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, indoor cranes, low-temperature applications
Delivery program Part No.
Number of cores and conductor nominal cross section [mm2]
Ethernet CAT5 New* CF14.01.04.02.CAT5 CF14.02.02.02.CAT5(2) CF14.02.04.02.CAT5 CF14.02.05.02.CAT5
External diameter approx. [mm]
(4x(2x0,14))C (2x(2x0,25))C (4x(2x0,25))C (5x(2x0,25))C
8,5 7,5 10,0 10,5
Copper index [kg/km]
Weight [kg/km]
39 33 46 53
75 43 101 106
The chainflex® types marked with (2) are cables designed as a star-quad. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalog.
Delivery program Characteristic Part No. wave impedance approx. [Ω] Ethernet CAT5 CF14.01.04.02.CAT5 100 CF14.02.02.02.CAT5 100 CF14.02.04.02.CAT5 100 CF14.02.05.02.CAT5 100
Number of cores Colour code and conductor nominal cross section [mm2] (4x(2x0,14))C white/brown, green/yellow, gray/pink, blue/red (2x(2x0,25))C white, green, brown, yellow (star-quad stranding) (4x(2x0,25))C white/brown, green/yellow, gray/pink, blue/red (5x(2x0,25))C white/brown, green/yellow, gray/pink, blue/red, black/violet
Order example: CF14.02.02.02.CAT5 – in your desired length (0,5 m steps) CF14 CAT5 chainflex series .02 Code nominal cross section .02 Number of pairs .02 Identification pairs .CAT5 CAT5 identification ®
Please use www.chainflex.eu/en/CF14 for your online order. Delivery time 24h or today.
Image exemplary.
Delivery time means time until shipping of goods.
eplan download, configurator
www.igus.eu/en/CF14
950 types from stock no cutting costs ... (for up to 10 cuts of the same type)
Test data Page 32 or www.igus.eu/en/test2 More CAT5/CAT6 cables Page 140, CFBUS
... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu
149