chainflex - complete catalogue

Page 1

Chain – cable – guarantee! Ask for fully harnessed and preassembled readychains® – increase your cash-flow and profit immediately. The igus® system guarantee also covers components delivered loose. www.readychain.eu

.eu/... ®

igus® GmbH Spicher Str. 1a D-51147 Cologne Tel. +49-(0)2203/9649-800 Fax +49-(0)2203/9649-222 info@igus.de www.igus.eu © 2012 igus® GmbH

®

®

Subject to technical alterations! MAT 0070582.20 Stand 6.2012

The goods leave igus® within 24 hrs. On request we can deliver via express or special delivery. Please inform us about your wishes.

No minimum order

igus® has no minimum order. Just order the amount you need.

From 1 m

Because chainflex® cables are of special high quality only the necessary length should be ordered. We appreciate each order from 1 m. Above orders of 1 m you may plan in 0.5 m steps.

With guarantee

Beyond the legal guarantee we also vouch for wear and tear. Together with you, we define your application‘s parameters. With a guarantee certificate!

Ordering times

From Monday to Friday 7.00 am - 8.00 pm Saturday 8.00 am - 12.00 pm

Hotline

Phone +49-22 03-96 49-800 Fax +49-22 03-96 49-222

Online shop

See www.igus.eu. There you can find our whole product range. Order around the clock.

You have questions?

For questions and more information call us or use our online product finders on www.chainflex.eu

www.chainflex.eu

.eu

/readychain

24 hrs delivery time

®

Certified according to DIN ISO 9001:2008

cables

/9001.2008

.eu...chainflex.cables...6.2012...plastics.for.longer.life...

Online shopping – 24h! www.igus.eu/24

chainflex

.eu/24 ®

®

Ordering and deliveries weekdays from 7.00 am - 8.00 pm, Saturday from 8.00 am - 12.00 pm. No minimum order quantities, no surcharges. 80,000 e-chain® products available ex stock. Prompt delivery. "Service around-the-clock". www.igus.eu Phone: +49-2203-9649-0 Fax: -222

chainflex.cables...6.2012...

www.chainflex.eu

.eu/... ®

plastics...

EU-CF-UM 2012-06 A5_EU-CF-UM 2012-06 A5 07.05.12 16:28 Seite 1


Chain – cable – guarantee! Ask for fully harnessed and preassembled readychains® – increase your cash-flow and profit immediately. The igus® system guarantee also covers components delivered loose. www.readychain.eu

.eu/... ®

igus® GmbH Spicher Str. 1a D-51147 Cologne Tel. +49-(0)2203/9649-800 Fax +49-(0)2203/9649-222 info@igus.de www.igus.eu © 2012 igus® GmbH

®

®

Subject to technical alterations! MAT 0070582.20 Stand 6.2012

The goods leave igus® within 24 hrs. On request we can deliver via express or special delivery. Please inform us about your wishes.

No minimum order

igus® has no minimum order. Just order the amount you need.

From 1 m

Because chainflex® cables are of special high quality only the necessary length should be ordered. We appreciate each order from 1 m. Above orders of 1 m you may plan in 0.5 m steps.

With guarantee

Beyond the legal guarantee we also vouch for wear and tear. Together with you, we define your application‘s parameters. With a guarantee certificate!

Ordering times

From Monday to Friday 7.00 am - 8.00 pm Saturday 8.00 am - 12.00 pm

Hotline

Phone +49-22 03-96 49-800 Fax +49-22 03-96 49-222

Online shop

See www.igus.eu. There you can find our whole product range. Order around the clock.

You have questions?

For questions and more information call us or use our online product finders on www.chainflex.eu

www.chainflex.eu

.eu

/readychain

24 hrs delivery time

®

Certified according to DIN ISO 9001:2008

cables

/9001.2008

.eu...chainflex.cables...6.2012...plastics.for.longer.life...

Online shopping – 24h! www.igus.eu/24

chainflex

.eu/24 ®

®

Ordering and deliveries weekdays from 7.00 am - 8.00 pm, Saturday from 8.00 am - 12.00 pm. No minimum order quantities, no surcharges. 80,000 e-chain® products available ex stock. Prompt delivery. "Service around-the-clock". www.igus.eu Phone: +49-2203-9649-0 Fax: -222

chainflex.cables...6.2012...

www.chainflex.eu

.eu/... ®

plastics...

EU-CF-UM 2012-06 A5_EU-CF-UM 2012-06 A5 07.05.12 16:28 Seite 1


EU-CF-UM 2012-06 A5_EU-CF-UM 2012-06 A5 07.05.12 16:29 Seite 2

chainflex® cable's classification according to the criteria requirements, oil-resistance and travel distance.

Give us your opinion!

Definition of the icons used in the catalogue

Yes, we can! Catalogue improvement. The chainflex® class is composed of 3 parts: Requirements 1 to 7

Travel distance 1 to 4

Requirements

Resistance to oil 1 to 4

Travel distance

To make the choice easier for you, we have classified all chainflex® cables according to the criteria "requirements, oil-resistance and travel distance". The higher the number the better the cable.

Dear costumers,

Example: You are looking for a cable which is suitable for the highest mechanical load. In addition, it should be oil-resistant following DIN EN 50363-10-2. The travel distance should be up to 100 m for freely suspended and gliding applications.

with every new chainflex® catalogue we agonize about how we can do the catalogue easier and better. And we know our catalogue so well that many details are totally clear for us. Then a costumer asks a detailed question and we notice, that it is not said that clear in the catalogue.

You choose from the classification overview (see left page): 1: Flexible cables

1: freely suspended

2: Highly flexible cables

2: freely suspended and gliding up to 50 m

3: Chain-suitable cables without special structure (e.g. stranding in layers) for the use in e-chains®.

3: freely suspended and gliding up to 100 m

4: Cables with special structure for permanent movement in e-chains® for medium requirements and radii from 7.5 x d, speed up to 3 m/s 5: Cables for permanent movement in e-chains® for high-load requirements and radii from 6.8 x d, speed up to 10 m/s 6: Cables for permanent movement in e-chains® for highest load requirements and radii from 5 x d, speed up to 10 m/s 7: Cables for permanent movement in e-chains® for highest load requirements and smallest radii, indoor and outdoor, radii from 4 x d, speed up to 10 m/s and more

4: freely suspended and gliding up to 400 m and more

Resistance to oil

Requirements: Travel distance: Resistance to oil:

6 3 3

This results in the cable's class – here "Class 6.3.3" that you can take out of each product's page.

Rainer Rössel Head of Business Unit chainflex® cables igus® GmbH, Germany

That's why we ask you for your oppinion. What do you like in the catalogue? And more important: What do you like not?

Send us an e-mail to chainflex-katalog@igus.de

Temperature range moved

Temperature range fixed

v max. unsupported/gliding

Torsion

a max.

Travel distance

UV-resistant

Nominal voltage

Testing voltage

Oil

Offshore

Flame-retardant

Silicon-free

Halogen-free

Lead free

Outer jacket

Outer jacket

CFRIP

Inner jacket

Intermediate jacket

Core stranding

Core identification

Conductor

Fibre Cables

Core insulation

Overall shield

Center element

Filling

Element shield

Element jacket

Material

Dimensions

Operating pressure

Vacuum

UL

UL/CSA

CSA

CEI

CE

DESINA

Clean room

NFPA

Toxicity

Gas density

Every comment is welcome - whether it's concerning usability, design, delivery tables, the tests or technical data. Thanks in advance for your cooperation.

1: No resistance to oil 2: Oil-resistant (following DIN EN 50363-4-1) 3: Oil-resistant (following DIN EN 50363-10-2) 4: Oil-resistant (following DIN EN 60811-2-1), bio-oilresistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA)

Best Regards Rainer Rössel Head of Business Unit chainflex® cables igus® GmbH, Germany

In theory the following classes would be possible: lowest "Class 1.1.1", highest "Class 7.4.4"


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:41 Seite 1

chainflex速 lasts or your money back!! igus速 tested!

22

Control Cables

56

Data/Coax Cables

110

Bus Cables

128

Fibre optic cable (FOC)

150

Measuring system cables

160

Servo Cables

186

Power cables/ Pneumatic hoses

202

Twistable cables

232

Special cables

254


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:43 Seite 2

Requirements

Travel distance

Resistance to oil

4

1

2

CF112

6

3

3

CF210.UL

4

1

2

CF113.D

6

3

3

CF170.D

4

1

3

CF27.D

6

3

3

CF180

4

1

3

CF14 CAT5

6

3

4

CFBUS.PUR

4

1

3

CF9.UL

6

4

4

CF111.D

4

1

3

CF10.UL

6

4

4

CF270.UL.D

4

1

4

CF11

6

4

4

CF130.UL

4

2

1

CF12

6

4

4

CF140.UL

4

2

1

CF Koax1

6

4

4

CF240

4

2

2

CFBUS

6

4

4

CF240.PUR

4

2

3

CF11.LC

6

4

4

CFLK

5

1

3

CF11.LC.D

6

4

4

CF THERMO

5

2

3

CF11.D

6

4

4

CF5

5

3

2

CF34.UL.D

6

4

4

CF6

5

3

2

CF35.UL

6

4

4

CF211 (Daten)

5

3

2

CF300.UL.D

6

4

4

CF211 (Mess)

5

3

2

CFPE

6

4

4

CF21.UL

5

3

2

CF310.UL

6

4

4

CF30

5

3

2

CF BRAID

6

4

4

CF31

5

3

2

CF BRAID.C

6

4

4

CF77.UL.D

5

3

3

CF CRANE

6

4

4

CF78.UL

5

3

3

CFLG.2LB

7

3

4

CF 77.UL.D (Robot)

5

3

3

CF9

7

4

4

CF ROBOT9

6

1

3

CF10

7

4

4

CF ROBOT2

6

1

3

CF98

7

4

4

CF ROBOT8

6

1

3

CF99

7

4

4

CF ROBOT4

6

1

3

CFLG.G

7

4

4

CF ROBOT6

6

1

3

CF37.D

7

4

4

CF ROBOT7

6

1

3

CF38

7

4

4

CF ROBOT5

6

1

4

CF330.D

7

4

4

CF ROBOT

6

1

4

CF340

7

4

4

CF2

6

3

3

CF FLAT

7

4

4

CF113

6

3

3

More information

Page 20/21

chainflex® cable

Resistance to oil

CFBUS.PVC

chainflex® cable

Travel distance

Selection chainflex® according to "Class"

Requirements

Selection chainflex® according to "Class"

chainflex® video-/vision-/ bus technology

266

chainflex® network technology

294

chainflex® CF.INI systems for initiators

314

readycable® Harnessed Cables

330

Connectors

452

chainfix Strain Relief Devices

487

readychains® Ready-made energy chain systems®

515

Designing with igus® Data and Schedules

522


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:43 Seite 4

Control cables

Page

Cross section Ø [mm2]

Number of cores

a max. [m/s2]

v max. gliding [m/s]

v max. unsupported [m/s]

Torsion resistant

UV-resistant

Halogen-free

Oil-resistant

Flame-retardant

Approvals and standards

Price index

chainflex types Temperature, fixed from/to [°C]

Temperature, moved from/to [°C]

Minimum bending radius, moved [factor x d]

Shield

Jacket

chainflex® cable

chainflex types

®

Minimum bending radius, fixed [factor x d]

®

56 CF130.UL

PVC

CF140.UL

PVC

CF5

PVC

CF6

PVC

CF170.D

PUR

CF180

PUR

CF77.UL.D

PUR

CF78.UL

PUR

CF2

PUR

CF9

TPE

CF10

TPE

CF9.UL

TPE

CF10.UL

TPE

CF98

TPE

CF99

TPE

7,5-10

-5/ +70

5

-20/ +70

3

2

20

2 - 42

0,25 - 6,0

58

7,5-15

-5/ +70

7,5

-20/ +70

3

2

20

3 - 42

0,25 - 2,5

62

6,8-7,5

-5/ +70

4

-20/ +70

10

5

80

2 - 42

0,25 - 2,5

66

6,8-7,5

-5/ +70

4

-20/ +70

10

5

80

2 - 36

0,25 - 2,5

70

7,5-10

-35/ +80

5

-40/ +80

3

2

20

3 - 30

0,50 - 10,0

74

7,5-15

-35/ +80

7,5

-40/ +80

3

2

20

3 - 18

0,50 - 2,5

76

6,8-7,5

-35/ +80

4

-40/ +80

10

5

80

2 - 42

0,25 - 4,0

78

6,8-7,5

-35/ +80

4

-40/ +80

10

5

80

3 - 42

0,50 - 4,0

82

5

-20/ +80

4

-40/ +80

10

5

80

3 - 48

0,14 - 1,5

86

5

-35/ +100

3

-40/ +100

10

6

100

2 - 36

0,14 - 35,0

90

5

-35/ +100

3

-40/ +100

10

6

100

2 - 25

0,14 - 4,0

94

5

-35/ +100

3

-40/ +100

10

6

100

2 - 36

0,25 - 6,0

98

5

-35/ +100

3

-40/ +100

10

6

100

2 - 25

0,25 - 4,0

102

4

-35/ +90

3

-40/ +90

10

6

100

2-8

0,14 - 0,5

106

4

-35/ +90

3

-40/ +90

10

6

100

2-8

0,14 - 0,34 108

These values are based on concrete applications or tests. These values do not represent the limit of what is technically feasible.

chainflex® types mentioned in the catalogue as “resistant to bio oil“ have been tested by DEA following VDMA 24568 with Plantocut 8 S-MB.

Table of contents according to industries Page 550 Table of contents according to part number Page 558

Get online and use all the advantages of www.igus.eu Download the eplan-library for any type of cables www.igus.eu/eplan-download 4

Chain – cable – guarantee! Ask for fully harnessed and preassembled readychains ® – increase your cash-flow and profit immediately. The igus® system guarantee also covers components delivered loose. www.readychain.eu 5


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:43 Seite 6

Data cables – Stranded in layers CF240

Page

Cross section Ø [mm2]

Number of cores

a max. [m/s2]

v max. gliding [m/s]

v max. unsupported [m/s]

Torsion resistant

UV-resistant

Halogen-free

Oil-resistant

Flame-retardant

Approvals and standards

Price index

chainflex types Temperature, fixed from/to [°C]

Temperature, moved from/to [°C]

Minimum bending radius, moved [factor x d]

Shield

Jacket

chainflex® cable

chainflex types

®

Minimum bending radius, fixed [factor x d]

®

110 PVC

10-12

-5/ +70

5

-20/ +70

CF240.PUR PUR

10-12

-20/ +80

5

-40/ +80

3

2

20

3 - 24

0,14 - 0,34 112

3

2

20

3 - 18

0,14 - 0,34 114

5

3

50

2 - 28

0,25 - 0,5

116

Data cables – Twisted pair CF211

PVC

7,5

-5/ +70

5

-20/ +70

CF113

PUR

10

-20/ +80

5

-40/ +80

10

5

80

4 - 12

0,25 - 0,5

118

CF11

TPE

6,8

-35/ +100

5

-40/ +100

10

6

100

2 - 36

0,14 - 2,5

120

10

5

80

4 - 12

0,25 - 0,5

122

10

6

100

4 - 28

0,25 - 1,0

124

10

5

100

1-5

Data cables – Twisted pair/Pair shield CF112

PUR

10

-20/ +80

5

-40/ +80

CF12

TPE

10

-35/ +100

5

-40/ +100

CF Koax 1

TPE

10

-35/ +100

7,5

-40/ +100

Data cables – Coax 126

Bus cables

128 CFBUS.PVC PVC

12,5

-5/ +70

7,5

-20/ +70

CFBUS.PUR PUR

12,5

-20/ +70

7,5

-40/ +70

CF BUS

TPE

10-12,5

-35/ +70

5

-40/ +70

CF11.LC

TPE

10

-35/ +70

5

-40/ +70

CF11.LC.D

TPE

10

-35/ +70

5

-40/ +70

CF14 CAT5

TPE

12,5

-35/ +70

7,5

-40/ +70

These values are based on concrete applications or tests. These values do not represent the limit of what is technically feasible.

2

30

2-8

0,15 - 0,5

134

2

30

2-8

0,15 - 0,5

136

10

6

100

2 - 13

0,08 - 1,5

138

10

6

100

2-9

0,25 - 1,0

144

10

6

100

2-6

0,25 - 1,5

146

10

6

100

4 - 10

0,14 - 0,25 148

chainflex® types mentioned in the catalogue as “resistant to bio oil“ have been tested by DEA following VDMA 24568 with Plantocut 8 S-MB.

Table of contents according to industries Page 550 Table of contents according to part number Page 558

6

* New in this catalogue.

7


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:44 Seite 8

Fibre optic cable (FOC)

Page

Cross section Ø [mm2]

Number of cores

a max. [m/s2]

v max. gliding [m/s]

v max. unsupported [m/s]

Torsion resistant

UV-resistant

Halogen-free

Oil-resistant

Flame-retardant

Approvals and standards

Price index

chainflex types Temperature, fixed from/to [°C]

Temperature, moved from/to [°C]

Minimum bending radius, moved [factor x d]

Shield

Jacket

chainflex® cable

chainflex types

®

Minimum bending radius, fixed [factor x d]

®

150

CFLK

PUR

12,5

-20/ +70

7,5

-25/ +70

10

5

20

1

980/1000 µm

154

CFLG.LB

TPE

5

-40/ +60

5

-40/ +60

10

6

20

2

50 + 62,5/125

156

CFLG. G

TPE

15

-40/ +60

8,5

-40/ +60

10

6

20

6 - 12

50 + 62,5/125 µm

158

Measuring system cables

160

CF211

PVC

10

-5/ +70

5

-20/ +70

CF111.D

PUR

12

-35/ +100

6

-40/ +100

CF113.D

PUR

10

-20/ +80

5

-40/ +80

CF11.D

TPE

10

-35/ +100

5

-40/ +100

5

3

50

6 - 16

0,14 -1,0

164

30

6 - 16

0,14 - 0,5

170

2

5

3

50

4 - 17

0,14 -1,0

174

10

6

100

4 - 17

0,14 - 1,0

180

Servo cables

186 CF210.UL

PVC

10

-5/ +70

5

-20/ +70

10

CF21.UL

PVC

7,5

-5/ +70

4

-20/ +70

10

CF270.UL.D PUR

10

-20/ +80

5

-40/ +80

10

CF27.D

7,5

-20/ +80

4

-40/ +80

10

PUR

These values are based on concrete applications or tests. These values do not represent the limit of what is technically feasible.

5

5

50

6-8

1,5 - 6 / Pairs 0,75 - 1,5

188

80

6-8

0,75 - 35 / Pairs 0,34 - 1,5

190

50

4-8

0,75 - 35 / Pairs 0,34 - 1,5

194

80

4-8

0,75 - 50 / Pairs 0,34 - 1,5

198

chainflex® types mentioned in the catalogue as “resistant to bio oil“ have been tested by DEA following VDMA 24568 with Plantocut 8 S-MB.

Table of contents according to industries Page 550 Table of contents according to part number Page 558

8

9


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:44 Seite 10

Power cables

Page

Cross section Ø [mm2]

Number of cores

a max. [m/s2]

v max. gliding [m/s]

v max. unsupported [m/s]

Torsion resistant

UV-resistant

Halogen-free

Oil-resistant

Flame-retardant

Approvals and standards

Price index

chainflex types Temperature, fixed from/to [°C]

Temperature, moved from/to [°C]

Minimum bending radius, moved [factor x d]

Shield

Jacket

chainflex® cable

chainflex types

®

Minimum bending radius, fixed [factor x d]

®

202 CF30

PVC

7,5

-5/ +70

4

-20/ +70

CF31

PVC

7,5

-5/ +70

4

-20/ +70

CF34.UL.D

TPE

7,5

-35/ +90

4

-40/ +90

CF35.UL

TPE

7,5

-35/ +90

4

-40/ +90

CF37.D

TPE

7,5

-35/ +90

4

-40/ +90

CF38

TPE

7,5

-35/ +90

4

-40/ +90

CF300.UL.D TPE

7,5

-35/ +90

4

-40/ +90

CFPE

TPE

7,5

-35/ +90

4

-40/ +90

CF310.UL

TPE

7,5

-35/ +90

4

-40/ +90

CF330.D

TPE

7,5

-35/ +90

4

-40/ +90

CF340

TPE

7,5

-35/ +90

4

-40/ +90

10

-20/ +80

7,5

-30/ +80

PU

10

-25/ +80

8

-40/ +85

CF Clean AIR PE

10

-25/ +60

8

-30/ +65

CF CRANE igupren

10

5

80

4-5

1,5 - 50

204

10

5

80

4-5

1,5 - 70

206

10

6

80

3-5

1,5 - 50

208

10

6

80

3-4

0,5 - 50

210

10

6

80

3-5

1,5 - 50

212

10

6

80

3-4

0,5 - 50

214

10

6

100

1

4 - 185

216

10

6

100

1

1,5 - 35

218

10

6

100

1

2,5 - 185

220

10

6

100

1

6 - 185

222

10

6

100

1

4 - 185

224

10

6

50

1

25 - 120

226

10

6

50

4 - 16

228

10

6

50

4 - 16

230

Pneumatic hose CF AIR

These values are based on concrete applications or tests. These values do not represent the limit of what is technically feasible.

chainflex® types mentioned in the catalogue as “resistant to bio oil“ have been tested by DEA following VDMA 24568 with Plantocut 8 S-MB.

Table of contents according to industries Page 550 Table of contents according to part number Page 558

10

11


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:45 Seite 12

Twistable cables

Page

Cross section Ø [mm2]

Number of cores

a max. [m/s2]

v max. gliding [m/s]

v max. unsupported [m/s]

Torsion resistant

UV-resistant

Halogen-free

Oil-resistant

Flame-retardant

Approvals and standards

Price index

chainflex types Temperature, fixed from/to [°C]

Temperature, moved from/to [°C]

Minimum bending radius, moved [factor x d]

Shield

Jacket

chainflex® cable

chainflex types

®

Minimum bending radius, fixed [factor x d]

®

232 CF ROBOT9 PUR CF77.UL.D

PUR

10

-25/ +80

4

-40/ +80

6,8-7,5

-35/ +80

4

-40/ +80

10 10

5

10

4 - 34

0,25 - 1

236

80

2 - 42

0,25 - 4,0

238

New* CF ROBOT2 PUR

10

-25/ +80

4

-40/ +80

10

10

4 - 18

0,75

242

CF ROBOT8 PUR

10

-20/ +70

7,5

-25/ +70

10

10

2-8

0,14 - 0,35

244

CF ROBOT4 PUR

10

-25/ +80

4

-40/ +80

10

10

6 - 12

0,14 - 0,5

246

CF ROBOT5 TPE

12,5

-20/ +60

7,5

-25/ +60

10

10

2

50 + 62,5/125 µm

248

CF ROBOT6 PUR

10

-25/ +80

4

-40/ +80

10

10

3

10 - 35

250

CF ROBOT7 PUR

10

-25/ +80

4

-40/ +80

10

10

3 - 12

0,25 - 4

250

CF ROBOT

10

-35/ +100

4

-40/ +100

10

10

1

10 - 50

252

TPE

Special cables – Data cables

254

CF THERMO PUR

12,5-15

-20/ +80

5

-40/ +80

2

1

20

10

6

100

2-5

0,23 - 0,5

256

1

2,5 - 4

260

Special cables – Power cables CF FLAT

TPE

5

-35/ +90

4

-40/ +90

CF BRAID

TPE

7,5

-35/ +70

4

-40/ +70

10

6

80

8

2,5

262

7,5

-35/ +70

4

-40/ +70

10

6

80

8

2,5

262

10

-20/ +70

5

-40/ +70

10

6

100

2-8

0,15 - 0,25 264

7,5

-10/ +80

5

-20/ +80

10

50

4-8

0,25 - 0,34 265

CF BRAID.C TPE

Special cables – Bus cables for hanging applications New* CFSP182

PUR

Special cables – Control cables for rail vehicles New* CFSP414

These values are based on concrete applications or tests. These values do not represent the limit of what is technically feasible.

chainflex® types mentioned in the catalogue as “resistant to bio oil“ have been tested by DEA following VDMA 24568 with Plantocut 8 S-MB.

Table of contents according to industries Page 550 Table of contents according to part number Page 558

12

* New in this catalogue.

13


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:46 Seite 14

®

®

®

chainflex readycable Cable type

Video-, vision engineering/bus technology (with camera reference list

Jacket

Page 288)

®

chainflex readycable Page

266

Selection table according to manufacturers

Jacket

Harnessed cables for Drive Technology

Page

330

FireWire

Ready-made cable

TPE

268

Allen Bradley New*

Power-/servo-/brake cable

PVC/PUR/TPE

338

USB

Ready-made cable

TPE

272

B&R

Servo-/resolver-/EnDat cables

PVC/PUR/TPE

338

GigE

Ready-made cable

TPE

276

Baumüller

Servo-/encoder-/pulse encoder-/ PVC/PUR/TPE

338

FOC

Ready-made cable

PUR

278

FOC

Ready-made cable (Robotics)

TPE

282

EtherCAT

PVC/PUR/TPE

341

Coax

Ready-made cable

TPE

284

Berger Lahr

Servo-/resolver cables

PVC/TPE

341

294

Control Techniques

Power-/servo-/encoder cables

PVC/PUR/TPE

341

resolver cable

Beckhoff

Network-/ethernet-/fibre cables (FOC)/fieldbus

Servo-/encoder-/resolver cables/

CFLG.6G

Gradient fibre glass cable, ready-made

TPE

296

Danaher Motion

Power-/servo-/signal cables

PVC/PUR/TPE

343

CFLG.12G

Gradient fibre glass cable, ready-made

TPE

298

ELAU

Servo-/encoder cables

PVC/PUR/TPE

345

CAT5

Ethernet cable, ready-made

PVC/PUR/TPE

300

Fagor

Path measurement cable

TPE

346

CAT5

Ethernet cable, ready-made, L-/T-angle

PVC/PUR/TPE

302

Fanuc

Power-/signal cables

PUR/TPE

346

CAT6

Ethernet cable, ready-made

TPE

306

Heidenhain

Adapter cable

PUR/TPE

347

Profibus

Field bus cable, ready-made

PVC/PUR/TPE

308

Jetter

Power-/servo-/resolver cables

PVC/PUR/TPE

347

314

Lenze

resolver-/decoder-/fan cable

PVC/PUR/TPE

348

Servo-/encoder cables

PVC/PUR/TPE

348

sensor-/fan cable

PVC/PUR/TPE

349

Power-/encoder-/control cable

PVC/PUR/TPE

350

Rexroth

Power-/encoder cables

PVC/PUR/TPE

350

SEW

Power-/servo-/encoder cables

PVC/PUR/TPE

352

Siemens

Power-/servo-/signal cables

PVC/PUR/TPE

353

Stöber

Servo-/encoder cables

PVC/PUR/TPE

354

Initiators CF9 - CF.INI (minimum bending radius 5 x d) Direct line/Connecting cable

TPE

New*

Servo-/encoder-/feedback-/

316

LTi DRiVES

New*

Initiators CF10 - CF.INI (minimum bending radius 5 x d) 360º shielded NUM Direct line/Connecting cable

TPE

Initiators CF98 - CF.INI (minimum bending radius 4 x d) Direct line/Connecting cable

Omron TPE

324

chainflex® cables for actuator/sensor distribution box New*

Direct line/Connecting cable M23

TPE

Power-/servo-/encoder-/

322

328

New*

"Allen Bradley" is a registered trademark of Rockwell Automation Inc, Greater Milwaukee / "B&R" is a registered trademark of Bernecker + Rainer Industrie-Elektronik Ges.mbH, Eggelsberg / "Baumüller" is a registered trademark of Baumüller Nürnberg GmbH, Nürnberg / "Beckhoff" is a registered trademark of Herrn Hans Beckhoff,Verl / "Berger Lahr" is a registered trademark of Schneider Electric Motion Deutschland GmbH & Co.KG, Lahr / "Danaher Motion" is a registered trademark of Danaher Motion Technology LLC, Delaware / "ELAU" is a registered trademark of Elektronik-Automations-AG, Marktheidenfeld / "Fagor" is a registered trademark of FAGOR Electronic Components Inc, New York / "Fanuc" is a registered trademark of Fanuc Ltd., Tokyo/Yamanashi / "Heidenhain" is a registered trademark of Dr. Johannes Heidenhain GmbH,Traunreut / "Jetter" is a registered trademark of Jetter AG, Ludwigsburg / "Lenze" is a registered trademark of Lenze GmbH & Co. KG, Extertal / "Omron" is a registered trademark of Omron Corp., Kyoto / "Rexroth" is a registered trademark of Bosch Rexroth AG, Lohr/ "SEW" is a registered trademark of SEW-EURODRIVE GmbH & Co KG, Bruchsal / "Siemens" is a registered trademark of Siemens AG, München / "Stöber" is a registered trademark of Stöber Antriebstechnik GmbH & Co. KG, Pforzheim

14

* New in this catalogue.

* New in this catalogue.

15


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:46 Seite 16

®

chainflex accessory Connectors

®

Page

452 Test order – test igus®!

453

chainflex

Technical Data and Schedules/user information/contact

Signal connector

454

SERIE B

Power connector

458

SERIE B

Power connector

460

SERIE M17

Signal- and power connector

522

Designing with igus® Cables and Hoses – General rules for cables and hoses in energy chains®

SERIE A

Page

®

524

Cables and Hoses – Separation in energy chains

525

Cables and Hoses – Further information on the separation of cables

526

Electrical Round Cables

527

Electrical Round Cables – Information on assembly and strain relief of electrical round cables

528

Pneumatic hoses

529

461

Data and Schedules SERIE C

Power connector

464

SERIE D

Power connector

466

SERIE S

Power connector

468

Tools, accessories

470

SUB-D

472

Signal connector

Yamaichi Y-CONKIT

476

Glands

478

DIN 47100 colour code/Copper wire dimensions according to Anglo-American AWG numbers

530

Calculation of the copper surcharge

530

Load-Carrying Capacity of Cables

531

Electrotechnical data

532

Chemical resistance

538

Informations The General Conditions

542

User information, Disclaimer, KTG, Product illustrations

542

Technical notes

542

Approbation and Approvals

chainfix Strain Relief

487

544 ®

Configure and order cables online, igus & eplan

548

igus at www.igus.eu

549

According to industries

550

Table of contents according to part number

558

More igus products ®

chainfix strain relief | Parameters | Overview

492

Clamps and stainless steel clamps – for maximum pull forces

546

®

494

Contact igus® C-profiles

500

Tiewrap plates – for universal tiewrap, bolted or clip-on

502

Tiewrap plates, with clip-on connection for the C-profile

504

Clips – high pull forces, plug-in

506

Fax – Customer-specific cables for energy chain systems®

554

Fax – System Planning

555

Fax – Harnessing

556

Fax – Order

557

®

igus worldwide Give us your oppinion – Catalogue improvement

Cover (back) Cover (back)

Strain relief separators - with integrated teeth

508

Definition of the icons used in the catalogue

Nuggets – for top hat rail and C-profile

510

chainflex® cables classification

Blocks – Special strain relief for hoses

511

What does the chainflex® "class"(ification) mean?

readychain®

Cover (ahead) 20

515 igus® readychain® Ready-made energy chain systems

®

16

564

516

17


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:47 Seite 18

How to use the catalog: chainflex® Cables

Jacket material and cable type

Cable name

Cable classes Classifcation of chainflex® cables according to requirements, resistance to oil and travel distance Product designation Designation of the selected chainflex® cable.

Short description Product data and brief description of the selected chainflex® cable.

Application area Description of typical cable applicatons.

Product illustration Description of the chainflex® cable design structure and detailed product illustration. Delivery program Table with part no., number of cores and conductor nominal cross section, copper index and weight.

Technical data Detailed description of the chainflex® cable, practical illustration by means of icons. Including all information, e.g. on temperature ranges, speeds, tensions, a description of the cable design. Order example

Chapter colour Every cable type has its own colour allowing faster catalog browsing.

Example Quicklink

www.igus.eu/en/CF340

Direct link to this product's online catalog: Free CAD-data, pdf files and more.

Approvals/standards

Contact

18

19


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:47 Seite 20

What does the chainflex® "class"(ification) mean? igus® has been supplying cables for permanent movement in e-chains® for more than 20 years now – chainflex® cables, which are quite simply good for one thing: Reliable function. To achieve this, all chainflex® cables in all e-chain® applications have to cope with demanding requirements, e.g. very small bending radii, high cycle rates, compact design spaces, a wide range of chemical influences and dynamic parameters. igus® carries out basic cable qualification tests according to igus® standards at its own Technical Centre and in the testing laboratory. These chainflex® qualification standards include series of tests which then lead to assignment to the respective igus® "class".

1. chainflex standard qualification "Materials" ®

Materials that are to be used for the series production of chainflex® cables must pass a whole series of endurance tests in e-chains® in addition to passing standard cable-specific tests (such as permanent alternate bending tests, ageing, abrasion, media resistance, flame resistance if appropriate etc.). These endurance tests, which can last up to 3 years, are always based on movement tests in and with e-chains®/ echain® materials and include: ®

● Permanent bending tests in e-chains at room temperature and with gliding and freely suspended travel distances. ®

● Permanent bending tests in e-chains at low temperatures and a travel distance of 8 m (at temperatures as low as -40 °C depending on the material) ● Permanent bending tests in e-chains® in different liquid media with a travel distance of approx. 0.5 m. ● Abrasion tests combined with chain materials.

3. chainflex® standard qualification "Approvals"

To make the choice easier for you, we have classified all chainflex® cables according to the criteria "requirements, oil-resistance and travel distance". The higher the number the better the cable.

These series of tests are based on the standards specified by the approval authorities and are carried out according to these specifications.

Example: You are looking for a cable which is suitable for the highest mechanical load. In addition, it should be oil-resistant following DIN EN 50363-10-2. The travel distance should be up to 100 m for freely suspended and gliding applications. You choose from the classification overview:

4. chainflex standard qualification "Production optimisation" ®

Following several years of qualification for the design and materials, the production methods are broken down and defined to machine level for qualification in order to keep the potential production tolerance as tight as possible. Cables are of course also taken systematically and continually from current production and subjected to a batch test. At igus®, the term batch test is used to mean the following: ● Recording and examination of the production parameters of the chainflex® cable.

On the basis of these series of tests, igus® has introduced the new selection and cable qualification system "class" to make it easier for customers to select the cable they require from among almost 1000 moving e-chain® cables. This "class"(ification) allows a fast and straightforward choice of cable for the application on hand.

This results in the cable's class – here "Class 6.3.3", that you can find on each product's page.

The chainflex® class is composed of 3 parts: Requirements 1 to 7

Travel distance 1 to 4

Resistance to oil 1 to 4

Resistance to oil 1: 1: No resistance to oil 2: Oil-resistant (following DIN EN 50363-4-1) 3: Oil-resistant (following DIN EN 50363-10-2) 4: Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA)

The "class" describes the load to be expected, the travel distance and the required oil/media resistance. The higher the class, the more complex the design principles and materials used. The lower the class, the more favourably priced are the cables with the same key electric data.

Travel distance 1: Freely suspended 2: Freely suspended and gliding up to 50 m 3: Freely suspended and gliding up to 100 m 4: Freely suspended and gliding up to 400 m and more

These series of tests, which can take between 1-3 years depending on the defined objective (e.g. double strokes), are always based on movement tests in and with e-chains® and include: ● Permanent bending tests in e-chains® at room temperature and with gliding and freely suspended travel distances. The radii are significantly smaller than those later defined in the catalogue.

Requirements 1: Flexible cables 2: Highly flexible cables

● Permanent bending tests in e-chains® with varying temperature curves between -40 °C and +60 °C – depending on design and material – with gliding travel distances and smaller radii than those later defined in the catalogue.

● Permanent torsion tests in triflex® e-chains® with movement programs on 6-axis robots.

6 3 3

● Execution of permanent bending tests in e-chain® test systems over short fast travel distances.

2. chainflex® standard qualification "Design"

● Permanent torsion tests in triflex® e-chains® with ±180 °/m with torsion cables on the torsion test stand, using 1 m triflex® e-chain®.

Requirements: Travel distance: Resistance to oil:

3: Chain-suitable cables without special structure (e.g. stranding in layers) for the use in e-chains®. 4: Cables with special structure for permanent movement in e-chains® for medium requirements and radii from 7.5 x d, speed up to 3 m/s 5: Cables for permanent movement in e-chains® for high-load requirements and radii from 6.8 x d, speed up to 10 m/s igus® has recently significantly expanded its testing laboratory for energy chains® and cables to 1,030 square metres. New standard products and customer-specific energy chains® can now be tested at more than 70 different test stands.

6: Cables for permanent movement in e-chains® for highest load requirements and radii from 5 x d, speed up to 10 m/s 7: Cables for permanent movement in e-chains® for highest load requirements and smallest radii, indoor and outdoor, radii from 4 x d, speed up to 10 m/s and more In theory the following classes would be possible: lowest "Class 1.1.1", highest "Class 7.4.4"

20

21


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:47 Seite 22

®

Fleece

Cores stranded in Layers Extruded, non-tensionproof centre element

Picture 1: Chain-suitable cable stranded Single-wire bundles in layers with short pitch lengths

chainflex ...

lasts or your money back!

The tricks and ingenious features of...

...the chainflex® design and why we feel so confident about this design

From the customer's point of view, a flexible energy supply system only needs to function properly. However, this demand presupposes the perfect operation of all components, including the cables being used in this system. And this is exactly where problems came up in the early 1980s. Due to constantly – and frequently even tremendously – increasing loads resulting from the application of automation technology, guided cables often failed although the energy supply system itself was functioning perfectly. In extreme cases, failures caused by "corkscrews" and core ruptures brought the entire production process to a standstill and resulted in high costs. In order to find a solution to this unsatisfactory situation for its customers, igus® decided to take the initiative. As the first company worldwide, igus® began to develop complete energy chain systems®. chainflex® cables and energy chains® are now being offered as a delivery from a single source and with a system guarantee depending on the application in each case. Based on the increasing know-how gained since 1989 and on the very sophisticated series of tests that have been conducted since then, design principles were and are still being created that help prevent machine downtimes in factories throughout the world today.

Stranding in bundles tried and tested expensively and efficiently millions of times since 1989 Stranding in bundles eliminates these problems by means of its very sophisticated, multiply stranded internal structure. Here, the litz wires are stranded with a special pitch length first and then the resulting cores are stranded into single core bundles. For large cross sections, this is done around a strain relief element. The next step is the renewed stranding of this core bundle around a tension-proof center – a genuine center cord. (see picture 2) Due to this multiple stranding of the cores, all cores change the inner radius and the outer radius of the bent cable several times at identical spacing distances. Pulling and compressing forces balance one another around the high-tensile center cord that gives the stranded structure its necessary inner stability. Accordingly, the stranding remains stable even under maximum bending stress (see picture 3).

How can "corkscrews" be prevented? Center element for high tensile stresses

Highly abrasionPicture 2: resistant, gussetLitz wire and filled extruded core structures jacket of a chainflex® cable Total shield with optimized braiding angle Picture 3: igus® stranding in bundles around center cord Gusset-filled extruded inner jacket

Center element for high tensile stresses 22

Here, the term "corkscrew" does not refer to a useful instrument for wine connoisseurs. Instead, it refers to the permanent deformation of guided, moved cables caused by excessive stressing – which, in most cases, results in core rupture almost immediately afterwards. How does this happen? How can "corkscrews" be prevented? An important factor here – in addition to a sensible design of the total energy chain system® – is the construction of the guided cables. Basically speaking, a clear distinction can be made between cables stranded in bundles and cables stranded in layers (see picture 4).

Properties of stranding in layers Stranding in layers is significantly easier to produce and is therefore offered on the market in so-called "chain-suitable" cables at low cost. But what appears to be tempting at first glance can quickly turn into an expensive mistake when a "corkscrew" immobilizes the system being operated with these cables. How do these problems arise? A look at the cable structure can be quite helpful (see picture 1). In the case of stranding in layers, the cable cores are mostly stranded more or less firmly and relatively long in several layers around a center and are then provided with a jacket extruded to the form of a tube. In the case of shielded cables, the cores are wrapped up with fleece or foils. But what, for example, happens to a similarly structured 12-core cable during normal operation? The bending process compresses, in the movement of the core, the inner radius of the cable and stretches the core in the outer radius. Initially, this works quite well because the elasticity of the material is still sufficient. But very soon, material fatigue causes permanent deformations, and then, due to excursion from the specified paths, the cores make their "own compressing and stretching zones": The corkscrew is created, then followed rather quickly by core ruptures most of the time.

Dictionary of defects Core rupture Failure of electric conductivity due to broken copper wires as a result of subjecting the individual cores to mechanical overload/ tensile load under constant bending stress. In most cases, the causes are incorrect litz wires and/or incorrect stranding pitch directions and lengths.

Insulation damage Short circuits due to damage to the insulation above the conductor. The cause can be material fatigue under constant bending stress or material abrasion within the stranded structure. Single-wire breakage of the conductor or the shield braid result in perforation of the insulation.

Corkscrew What are EMC problems and shield wire breakage? In principle, cable shields must fulfil two tasks: ● Protecting the cables from external interferences ● Shielding any interferences before transmitting them to the outside Both tasks are equally important because faulty signals can cause considerable consequential damage in the system itself as well as in any external systems. Furthermore, this is an especially problematic point due to the fact that incorrect shielding usually cannot be detected from outside, and this is something that makes the trouble-shooting procedure extremely difficult. How can these kinds of problems arise in the first place? Once again, the answer is to be found in the internal structure of the cable itself: Is the shielding designed for the movements of the cable? Although it may be very easy to shield a fixed cable, it is much more difficult to guarantee the permanent shielding of a moving cable. In the case of so-called "chain-suitable" cables, for example, the stranding bond of an intermediate layer is wrapped up with foils or fleeces. This stranding bond is supposed to guarantee the separation between the cores and the shield braid. But something that functions quite well for the fixed installation of cables is often quite insufficient in the case of moving cables. This has to do with the fact that the foils and fleeces do not create a bond between the stranding, shield and jacket and may fall apart under stress. Consequently, the metallic shield then rubs on the insulation of the cores – short circuits are then to be expected.

An externally detectable screw-like deformation of the entire cable due to broken copper wires as the result of subjecting the individual cores to mechanical overload/ tensile load during the bending process. In most cases, the causes are unfavorable superstructure properties (stranding in layers, missing center, loose jackets extruded to the form of a "tube") and subjecting the cables to high bending stress.

Jacket abrasion The jacket is rubbed off down to the stranding or down to the total shield. In most cases, the causes are incorrect selection of materials and/or unfavorable extrusion processes resulting in detrimental surface properties so that abrasion is an unavoidable effect.

Jacket swelling/ jacket breakage Jacket becomes soft and deformed or breaks until the stranding/shield can be seen. The cause can be the incorrect selection of materials with respect to the oils or other chemical substances being used.

Shielding losses/ EMC problems Electromagnetic interferences inside or outside an electric cable. In most cases, the cause is shield wire breakage due to mechanical overload with incorrect shield braid angles. Other causes include loose braids over foils without supporting effects or very open coverings.


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:47 Seite 24

®

chainflex ...

lasts or your money back!

The tricks and ingenious features of...

...the chainflex® design and why we feel so confident about this design

But the production of the shield itself is very time-consuming and cost-intensive and may have been the reason for the use of open braid shields or even simple wire wrappings. The disadvantages are quite obvious: Open shields only possess a limited shielding effect in their moved state – motion and expansion reduce this effect even further. The type of shield is therefore an important point that is not even mentioned in some catalogues.

Gusset-filled extruded jacket

In its up to approx. 70% linearly and approx. 90% optically covered cables, igus® eliminates these weak points by means of an optimized internal structure. In virtually all shielded chainflex® cables, a gusset-filled extruded inner jacket over the stranded structure is therefore used. This "second jacket" fulfils two tasks: ● It holds the stranded structure together and guides the individual cores as in a channel. ● It serves as a firm, round base for a very tight-fitting shield.

Here, not only the material is an important factor but also the production process. In the case of the so-called "chain-suitable" cables, the jackets are usually produced extruded to the form of a tube and therefore do not provide the stranded structure with the necessary support for constant bending processes. The stranded structure can fall apart.

a channel. The special characteristic of this type of production is that the intermediate spaces, which are created between the cores during the stranding process, are completely filled with jacket material by the high extrusion pressure. As a result, the jacket material creates a channel-like guide which allows the cores to carry out a defined longitudinal movement. The jacket also provides a supporting function for the stranding.

The quality bundles of igus® chainflex® cables Therefore, igus is the first manufacturer of energy chain systems to offer the so-called the "gusset-filled extruded" jacket. ®

®

Here, the jacket material is injected between the core stranding powdered with talc and ensures that the stranded structure does not open up and also makes sure that the cores are guided as in

● ● ● ● ● ●

Strain-relieving center Stranding in bundles Gusset-filled extruded inner jacket in shielded cables Enclosed shield braid Optimized shield braiding angle Gusset-filled extruded jacket

Shield wire breakage – and how this can be prevented And even during the production of the shield, there are many things that can be done correctly – or incorrectly. Here, an important parameter is the braiding angle. In the case of "chain-suitable" cables, a tensile load of the shield wires in the outer radius of the cable must usually be taken into account. If an unfavorable braiding angle is to be added, the tensile load increases even further and shield wire breakage is the result. The consequences range from reduced shielding effects right up to short circuits whenever the sharp wire ends penetrate through the fleeces or foils into the cores. Here, a useful tip: If, after the insulation has been stripped off, the shield can be easily pushed back over the jacket, the shield is then usually unsuitable for use in moved flexible energy supply systems! This is a problem that igus® has now solved with its direct approach:

Jacket breakage at (36x0.142) after only 900.000 to-and-fro cycles with a bending factor of 7.8 x d

● The shield braiding angle determined in long-term tests efficiently neutralizes the tensile forces and is therefore highly suitable for energy chains®. ● Due to the stable inner jacket, the shield cannot wander uncontrolled. ● The shield itself has a torsion protection effect on the stranded structure.

7 basic rules for a good cable 1. Strain-relieving center Clear space is created in the center of a cable according to the number of cores and the cross section of each cable. This center should be filled, as far as possible, with a genuine center cord (and not, as frequently the case, with fillers or dummy cores consisting of waste materials). These measures will then efficiently protect the stranded structure situated above and prevent the stranding from wandering into the middle of the cable.

2. Litz wire structure With respect to the selection of litz wires, the maximum flexibility has proved to be the best solution. Although very flexible conductors can be made using very thin individual wires, these conductors tend toward extreme formation of kinks. Long-term series of tests provided the result of a shielded combination of single-wire diameter, pitch length and pitch direction as the best bending-resistant solution.

3. Core insulation Jacket abrasion/ jacket breakage Whereas defects in the internal structure are hardly detectable on the outside, jacket problems strike the eye immediately. The jacket is the first protection for the complicated internal structure. This is why broken, worn and swollen jackets are a serious quality defect. To prevent this problem, the igus® customer can select among 7 acket materials to adapt his energy chain® cables to suit the conditions of the respective environment.

The insulation materials must be made so that they do not stick to one another within the cable. Furthermore, the insulation is also required to support the stranded individual wires of the conductor. Accordingly, only the highestquality, high-pressure-extruded PVC or TPE materials that have proved their tested reliability in millions of core kilometers are then used in energy chain® applications.

4. Stranding The stranded structure must be stranded around a stable, tension-proof center with an optimized short pitch length.

24

However, due to the insulating materials being used, this stranded structure should still be defined in mobile form within the stranding. Starting from a quantity of 12 cores, however, the method of stranding in bundles should be applied.

5. Inner jacket A gusset-filled extruded inner jacket must be used instead of inexpensive fleeces, fillers or accessory fillers. This measure ensures that the stranded structure is efficiently guided in longitudinal direction. Moreover, the stranded structure cannot fall apart or wander off.

6. Shielding The total shield should be made tight using an optimized shield braiding angle over an extruded inner jacket. Loose open braids or wrapped stranding reduce the EMC protection considerably and can fail very quickly due to shield wire breakage. A tight total braid shield also has a torsion protection effect on the stranded structure.

7. Outer jacket The material-optimized outer jacket can fulfil many different requirements: From UV-resistant to low-temperature-flexible, and from oil-resistant to cost-optimized. But these outer jackets must have one thing in common: A jacket material must be highly abrasion-resistant but not be allowed to stick to anything. It must be flexible but also provide a supporting function. In any case, the jacket should also be extruded under pressure (gusset-filled). 25


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:48 Seite 26

®

Sectional views through

the igus cable types

Detailed structure of igus® control, data, servo and motor

cables

chainflex® control cable, unshielded Individual bundles with optimized pitch length and pitch direction

chainflex® FOC gradient fibre cable Supporting braid made of glass-yarn-stranded GRP rods

Center element for high tensile stresses

Gel-filled fibre sheath FOC fibres

Single-wire diameter optimized for energy chains®

Highly abrasion-resistant, gusset-filled extruded jacket

chainflex® control cable, shielded Total shield with optimized braiding angle (covering approx. 70% linear, approx. 90% optical) Gusset-filled extruded inner jacket supports stranding Center element for high tensile stresses Tension-proof center element in individual bundles Pressure extruded jacket

chainflex® data/ sensor cable, shielded Stranded elements with optimized pitch length and pitch direction Gusset-filled extruded inner jacket supports stranding Center element for high tensile stresses

Highly abrasion-resistant TPE jacket

Integrated torsion protection

chainflex® servo cable, shielded Total shield with optimized braiding angle (covering approx. 70% linear, approx. 90% optical) Optimized single-wire diameter Center element for high tensile stresses Gusset-filled extruded inner jacket Stranding with optimized pitch length and pitch direction Pair braid shield over optimized stranded core pair Highly abrasion-resistant pressure extruded jacket

chainflex® power cable, shielded Total shield with optimized braiding angle (covering approx. 70% linear, approx. 90% optical) Gusset-filled extruded inner jacket Center element for high tensile stresses

Pair braid shield Optimized single-wire diameter Total shield with optimized braiding angle (covering approx. 70% linear, approx. 90% optical) 26

Pressure extruded jacket

Stranding with optimized pitch length and pitch direction Highly abrasion-resistant pressure extruded jacket

27


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:48 Seite 28

chainflex are the special cables for energy ® chain systems – tested, tested, tested and tested. ®

Partial view of igus® experimental laboratory – testing, testing, testing of chainflex® cables

Purpose of every chainflex cable

®

More sensitive applications with high clock cycle numbers, velocities and accelerations as well as sophisticated environmental conditions call for, especially in the field of energy management, tried-and-tested systems that are functionally efficient for a long period of time. EMC safety and the fulfillment of standards and directives such as UL, CSA, VDE, Interbus and Profibus are a necessary requirement today. After all, your automation system is supposed to function correctly non-stop and worldwide even on a low-cost basis. That’s the igus® mission.

No contradiction: Good cables cost less.

number of double strokes

Testing of a chainflex® CF5: 7 x 1 in "short" and "long" distances of travel compared with other cables. CF5 with 4,3 x d bending radius "Short Travel" "Long Travel"

Quick availability throughout the world is a significant purchase

* Cables OK, test abandoned.

criterion. Advantages of our cables: successful tests, presence in more than 40 countries around the world and deliverability ex warehouse. This saves time, money, storage capacity and applies to each one of our 950 cable types which you can order without any minimum quantity purchases or surcharges. Which further advantages can be included is something that depends on your specific conditions of use.

number of double strokes

Testing of a chainflex® CF5: 25 x 1 in "short" and "long" distances of travel compared with other cables. CF5 with 4,3 x d bending radius "Short Travel" "Long Travel"

igus tested ®

* Cables OK, test abandoned.

As a manufacturer of energy chains® and special energy chain® cables, igus® uses the possibility of testing many different types of chains and cables on a practice-oriented basis. At the company-own technical training center in Cologne, numerous series of tests are carried out on a parallel basis under the most difficult conditions. At the present time, there are more than 35 test setups with their test results being summarized in databases. This extensive, current data pool provides precise, reliable information on the actual service life and is also the basis of new product developments at the company. The test data for energy chains® and cables, but also for readymade systems, are, however, described in such detailed form that igus ® confirms a functional guarantee for its energy chain systems®. 28

29


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:48 Seite 30

Example 1: tested, tested, tested! Servo cable structure

Comparison between the igus ® solution with the gusset-filled internal jacket and the fleece version with fillers Here, the servo cables are highly flexible motor connection cables with a complete copper shield and an integrated, shielded pair of control cores. This cable type was selected due to the fact that here the problematic case of an outof-round braid form due to the different core cross sections is a significant factor and that the various bending behaviors of the production methods are therefore emphasized. n Sample A: CF27.100.10.02.01.D (igus® GmbH)

Conductor

(4x10 mm2) + (2x1,0 mm2) n Sample B: experimental

core insulation sheath made of TPE

(4x10 mm2) + (2x1,0 mm2)

fleece polyester foil ● ●● ●● ●● ●●● ● ●● ●● ●●● ● ●●

●● ● ●●● ● ●●●● ●●● ● ●●●● ●●

●●● ●●●● ●●●● ●●●● ●●●● ●●

●●● ●●●● ●●●● ●●●● ●●●● ●●

aluminum-coated polyester foil

Both cables are provided with identical nominal cross sections and insulation materials. Cable A is equipped with an internal jacket and cable B with a fleece taping and fillers. The experimental production (sample B) already shows the formation of a corkscrew after 145.000 double strokes. In the case of a cable, the so-called corkscrew refers to a wave-shaped deformation like the one that can be seen in the following picture on sample B.

shield center filler Inner jacket made of TPE-E

Sample B with fleece and filler experimental production 4x10+(2x1,0) C

30

The purpose of the test is to determine the advantages of the more expensive internal jacket in shielded servo cables versus the less expensive fleece taping with fillers. In the case of flexible shielded cables, the shield is usually separated from the composite core structure. On the one hand, this is done in order to achieve a rounder braid form and, on the other hand, the friction of the core insulation sheath against the braided shield structure is prevented due to the separation of the cores and shield. This can be achieved with an internal jacket or a fleece taping which is wrapped around the composite core structure. The internal jacket is more sophisticated and is therefore more expensive to produce. Following the twisting process, the composite core structure must run through the extruder in which the internal jacket is then put on. In contrast to this method, the fleece tape can be put on between the twisting point and the reeling-up device during the twisting process and therefore does not require an own work operation.

Sample A with internal jacket igus® chainflex® CF27.100.10.02.01.D

Product information CF27.D Page 198

Whereas, in the case of cable A, the internal jacket fills up the gussets and a round braid structure is created as a result, cable B requires fillers in the gussets. Like the core, the fillers also consist of filbrated polyethylene. They are easy to compress and are therefore hardly capable of taking over any supporting effects. Whereas the internal jacket, which is made of TPE, and the cable A center, which consists of cordage, hold the cores in a defined position, the cores of cable B are able to move about uncontrolled. During the bending process, a core has detached itself from the composite braid structure and has been shifted in the inner bending radius with respect to the center and on the outer bending radius with respect to the jacket. This results in corkscrew-type deformations that repeat themselves periodically with the pitch length.

Assessment Despite the extremely low bending factor of 4,76, no signs of wear can be detected in sample A (CF27.100.10.02.01.D) even after 5 million double strokes. Sample B, on the other hand, with its fillers and fleece taping succumbs to a corkscrew formation already after 145.000 double strokes. Accordingly, the result therefore justifies the extra expenditure of the cable with the gusset-filled internal jacket.

5.000.000

Number of double strokes

external jacket made of TPE-E

5.000.000

4.000.000 3.000.000 2.000.000 1.000.000 750.000 500.000 250.000

145.000

100.000 50.000 0

Sample B

Sample A

Sample A: CF27.100.10.02.01.D

Sample B: experimental production 31


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:48 Seite 32

Example 2: tested, tested, tested! Technical Data Properties CAT5

MHz

0

10

20

30

40

50

60

70

80

90

100

0 -5 -10 -15

Alteration of the electrical transmission properties of a CAT5 cable when subjected to an application of stress with the minimum bending radius

-20 -25

max. norm value new condition

-30

according to 332.269 double strokes according to 686.767 double strokes

High transmission rates of up to 100 Mbit/s place high demands on the cable structure and its materials. The use of the cables in energy chains速 subjects these materials to additional stress and results in long-lasting alterations of the electrical properties. A CF 14.02.04.02.CAT5 cable was selected as a cable to be inspected for high transmission rates. Even when subjected to an application of stress with the minimum bending radius, the cable must also be able to meet the electrical requirements of the IEC 61156-6 standard. In the case of the CF14.02.04.02.CAT5 cable, four pairs of cores are stranded with one another, with each core pair possessing a nominal cross section of 0,25 mm2. The conductor consists of bare copper wires and is surrounded by an insulation sheath consisting of foamed PE.

The following items were inspected: n Characteristic wave impedance of single pairs n Single-pair attenuation n Return loss of single pairs n Near-end crosstalk attenuation of

according to 1.561.281 double strokes

-35 dB/100 m

Attenuation The maximum values of the individual attenuation for each pair of cores are specified for the corresponding nominal characteristic wave impedance in dB/100m in the DIN IEC 61156-6 standard. Accordingly, the cables are subdivided into several categories according to the transmission frequency planned to be used. For the cable being inspected, transmission frequencies of up to 100 MHz are planned to be used, which corresponds to the category 5e.

single pairs versus one another

Test result The test is to be carried out in order to determine whether the limit values of the IEC standard are complied with by the cable after being subjected to bending stress.

The attenuation, as a measure of the reduction of the transmitted electrical energy of a signal on the cable, remains, even after more than 1,5 million double strokes, below the specified limit value while being subjected to the application of stress of the minimum bending radius. The characteristic electrical transmission quantities such as characteristic wave impedance, return loss and near-end crosstalk are fulfilled so that, despite applications of high mechanical stress, the electrical values of the IEC standard are complied with for a cable of the category 5.

Product information CF14 CAT5 Page 148 32

33


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:49 Seite 34

Example 3: tested, tested, tested! “Millions of double strokes” in an energy chain Profibus cables in permanentlymoving industrial use For users, it is hard to get an overview of the cable market. Competition between cable suppliers is intensifying and manufacturers are outshining one another in their promises to “guarantee service life for cables used in energy chains”. Catalogues claim ten million - or even as many as 50 million - double strokes when it comes to the service life of cables used in applications involving movement. On taking a closer look at figures claimed, one must ask how testing was done, or how realistic tests carried out actually were (for example length of travel, test radii, etc.) in order to be able to provide such a guarantee. Even information stating that cables are tested in accordance with VDE (Association of German electrical engineers) 0472, Part 603, test method H, is not helpful when it comes to determining the service life of a cable in energy chains, since the roller testing stand cannot provide any conclusive results and there is no VDE test for special cables in energy chains.

Differences in service life At the beginning of 2002, a test to determine the service life of profibus cables in a real application was commissioned in igus’ test laboratory. The aim was to examine any differences in the service life of igus’ CFBUS.001 chainflex® cable and another market leading profibus cable. The parameters required for the test were selected on the basis of data contained in the competitor’s catalogue: Catalogue details

Cross section Guaranteed lifetime Bending radius Diameter Catalogue details

Test item “A” Twin-core profibus cable

Test item “B” igus® chainflex® CFBUS.001

(2 x AWG24)C

(2 x 0,25 mm2)C

Min. 4,0 Mio. Cycles To be determined in a test > = 60 mm

85 mm

8,0 mm

8,5 mm

Issue 2002

Issue 2002

Test parameters according to catalogue data of the competition A gliding application was chosen as a suitable test structure since profibus cable systems are usually used here because of their data integrity, particularly over long lengths of travel and long transmission distances.

Structure and materials

Number of double strokes

The main reason for the major differences in service life is the differing structural parameters of test item “A“ and test item “B“ (CFBUS.001), as well as the different materials used for producing the cables. The conductor insulation of the bus comprised of a foam material for all the test items. The electrical assets of this material ensured better transmission properties were achieved. A disadvantage of this material, however, was its weakness under reverse stresses. The forces which affect the bus pair should be absorbed by the element sheathing in order to alleviate the mechanical stress of the conductor insulation.

Highly-elastic element sheathing For this reason, test item “B“ (igus®) was provided with a mechanically superior, extruded TPE inner, or element, gapfilling sheathing, in order to protect the bus pair against mechanical influences during the bending procedure. The element sheathing must be highly elastic. A mechanically inferior element sheathing made of inexpensive filling material only serves to make the bus pair round, just like frequently used fillers or banding. It is not able to protect the buses from the high degree of mechanical stress present in the chain. Tensile and compression forces which occur mainly influence those parts of the cable core in which there is a break in the element sheathing. Test parameters Distance of travel:

S = 5,0 m

Speed, approx.:

V = 3,5 m/s

Acceleration, approx.:

a = 7,5 m/s

Radius, approx.:

55 mm

2

The sheathing of test item ”B“ (CFBUS.001) is on the one hand characterized by a mechanically superior, gusset-filled TPE element jacket, which mechanically relieves the bus pair, fixes the cores in a defined position and bends. The sheathing of test item ”B“ (CFBUS.001) is on the one hand characterized by a mechanically superior, gusset-filled TPE element jacket,

Test item “A”

CFBUS.001, Test item “B”

which mechanically relieves the bus pair, fixes the cores in a defined position and bends. The extremely short pitch of the core strands and special cable also ensure that no great tensile or compression force has an effect on a long length of core.

UL and CSA approval chainflex® CFBUS cables are now also available for all standard field bus systems, complete with UL and CSA approval and DESINA compliance. The highly abrasion-resistant, flameretardant TPE outer jacket is extruded onto the fully braided shield with an adjusted twisted angle in order to provide the cable with additional stability. The bus elements braided with a particularly short strand pitch are protected by means of a gap-filling, extruded TPE inner jacket. The bus parameters required are fulfilled by means of a choice of coordinated insulating materials and production procedures. As with all chainflex® cables, the new standard field bus cables of the CFBUS series are now available ex stock, without any cutting costs or extra charges for small quantities.

Product information CFBUS Page 138

In order to be able to carry out non-destructive testing and hence achieve a large number of bending cycles in a short period of time, a genuine profibus transmission path was erected. In a PC at the fixed end of the test chain there was a profibus master insert card. A connection to a profibus slave was located on the moving end. This enabled the transmission rate to be determined with the help of a diagnosis program. Any data packets which might have been transmitted incorrectly could be indicated. The highest-possible transmission rate of 12 megabits/s was set.

The fundamental test, which commenced at the beginning of 2002 and is still in progress today, showed that only a relatively low number of cycles (420.000) resulted in the total failure of test item “A“, which, according to the competitor’s catalogue, should have functioned safely for at least 4.0 million cycles. Thus the real lifetime reaches only about 10% of the stated catalogue value.

Picture: Sliding application as the basis of the test structure

34

On the other hand test item “B“, the CFBUS.001, is still undergoing testing without any faulty data transmissions. So far, it has accomplished more than 14.0 million cycles.

Position of the broken element jacket

Position of the broken core insulation Fig. 3: A mechanically low-quality element jacket can’t protect the bus pair against the high mechanical loads inside the energy chain®.

35


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:49 Seite 36

Example 4: tested, tested, tested! CF98 with < 4xd!

Test 1: Inspection of four different cable designs Four different cable constuctions has been analyzed: Test item A – conductor with special conductor alloy Test item B – conductor same as test item A, but in copper Test item C – conductor in braided structure Test item D – conductor in stranded construction This long-term inspection, which was carried out over a period of 2 years, provided the following results:

Test set-up: Horizontal, short distance of travel

For users of very small energy supply chains with mostly very narrow bending radiuses, the question for a suitable cable for very high stroke numbers has come up frequently in the past.

Test parameters

At bending radiuses of less than 5xd, copper quickly reaches its physical limits, which necessitated the search for suitable substitute conductor materials or for fundamentally different conductor superstructures.

Distance of travel:

S = 0,8 m

Speed, approx.:

V = 1,5 m/s

Acceleration, approx.:

a = 0,5 m/s2

Radius, approx.:

18 mm

Test 2:

Number of double strokes

Test item A 47.434.277 450.000 Test item B 638.000 Test item C Test item D 2.350.000

Cross d [mm] section

Testradius

7x0,20

5,8

3,1xd = 18

7x0,20

5,6

3,2xd = 18

7x0,25

7,3

2,5xd = 18

7x0,25

7,3

2,5xd = 18

Two different cable designs were tested, whereby different core numbers and cross-sections were selected in comparison with test 1: Test item A – conductor with special conductor alloy Test item B – conductor in copper In this case, test item B was manufactured completely identical to test item A except for the conductor material. The test showed that not a single case of wire breakage could be detected for test item A even after 28 million double strokes. Test item B, however, only achieved approx. 1,4 million double strokes before complete destruction of the conductor was determined. This test also demonstrates that the alloy concept clearly surpasses the life of the copper conductor by more than 19 times and achieves these extraordinary results in the mechanically critical area of very small cross-sections! Number of double strokes

Test item A 28.267.000 Test item B 1.450.000

Number of double strokes

Cross d [mm] section

Testradius

2x0,14

3,9

4,6xd = 18

2x0,14

2,9

6,2xd = 18

Number of double strokes

Many series of tests with a variety of conductor superstructures and materials were performed in order to find out how cables must be manufactured in order to be able to endure several millions of bending operations in e-chains®, even at bending radiuses of less than 4xd.

Testradius

Test item A 3,1xd

Test item B 3,2xd

Test item C 2,5xd

Test item D 2,5xd Testradius

Test item A 4,6xd

Test item B 6,2xd

Conductivity of alloys

Be nd ing rad ius =

4x

d

However, the outstanding mechanical properties of this alloy have to do with a reduced conductivity versus copper, which can be compensated by means of slightly increased cross-sections. This means that the cross-sections mentioned in the catalog meet the electrically defined cross-sections defined using the conductivity value. The conductor diameter of the alloyed conductor increases slightly compared to the conductor diameter of a copper conductor. This compromise results in a 10% greater external diameter for the CF98 series versus a comparable CF9 type, although the service life differences to be expected between the CF98 versus the CF9 speak for themselves and increase by a multiple factor in comparison with other so-called chain-suitable cables.

Product information CF98 Page 106 36

As in the case of the CF9 series, further characteristics of the chainflex® CF98 include the highly abrasion-resistant, gusset-filled extruded TPE outer jacket, the oil resistance and the UV resistance as well as the absence of any PVC and halogen compounds. Especially in areas of application that only possess minimum construction space but also demand a large number of strokes, the igus® cable offers an increased degree of operational safety and efficiency. Areas of application are available in the semiconductor and component parts industry, in the automation sector as well as in the automotive and bank sector. New possibilities of application can also be found in automatic doors for motor vehicles and trains as well as in automatic food and selfservice machines and in the packaging industry. 37


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:49 Seite 38

Plastic fibre-optic cables in energy chains®

Figure 2: Course of the increase in attenuation as a function of the number of cycles. Increase in attenuation as a function of the number n of travel movements

Course of the increase in attenuation as a function of the tensile force

A in dB

A in dB

Example 5: tested! Dispersion and attenuation

Figure 1 represents test results for a chainflex®-cable with 6 fibre-optic cables. The length of the test sample is 1m and the maximum tensile load 250 N.

Force F in N Number of cycle's n x 100.000

Plastic fibre-optic cables have been introduced for data transmission in industrial applications due to their excellent interference-proof properties against electro-magnetic fields and further advantages such as the possibility of reducing dimensions and weights. The application as flexible link lines particularly in energy supply chains places high demands on plastic fibre-optic cables. The most important characteristic values of a fibre-optic cable are dispersion and attenuation. Dispersion is the term used to describe the scattering of the travel time of the signal in the fibre-optic cable. In plastic fibre-optic cables this is essentially caused by the mode dispersion, which arises from the different travel times of individual light beams. Dispersion determines important transmission properties such as bandwidth, cut-off frequency or maximum bit rate. Significant changes in dispersion could not be ascertained in any of the investigations carried out. The industrial application of igus® chainflex®-cabes with plastic fibre-optic cables in supply chains for example is therefore unproblematic with regard to changes in dispersion. The second important characteristic property, attenuation, determines the maximum possible length of a transmission path. The attenuation of a plastic fibre, like that of the glass fibre, is also strongly dependent on the wavelength of the light used. For this reason all the investigations were carried out with a wavelength of 660 nm. Depending on the output of the transmitter and the sensitivity of the receiver the operator has a certain "attenuation budget" available for the complete transmission path including all junction and transition regions. This attenuation budget (typical value approx. 20dB) must not be exceeded if a secure transmission of the data is to be guaranteed. For this reason it is of great interest to the user to know whether and to what extent increases in attenuation are to be expected for his particular application so that these can be taken into account in the compilation of his own attenuation budget. In addition to continuous bending stress, which is typical for operation in an energy supply, further mechanical stresses that can occur during installation or operation must be taken into account. Thus, for example, relatively large tensile forces can occur when integrating the line into an energy supply. The fixing of the cables at the ends of the energy chain using cable clamps leads to permanent transverse loads. The test of the behaviour under transverse load is carried out following DIN VDE 0472, Part 223. Since the cable clamps only exercise pressure in an area covering a few centimetres, increases in attenuation are relatively low. Attenuation under tensile load depends to a great extent of course on the composition of the line. Cabes with integrated copper conductors or strain relief elements do not reveal a noticeable increase in attenuation until very much greater tensile forces are applied than is the case with pure fibre-optic cables. 38

The tensile forces required to integrate fibre-optic cables in energy chains® are usually much lower than 250 N. The increase in attenuation was 0,17 dB at maximum tensile force and disappeared completely after the tensile load was released. Thus no effect on attenuation should be expected. In the case of plastic fibre-optic cables that are bent very often, as is the case in applications with energy chains®, then further influencing factors such as material fatigue, dulling of the materials, micro-cracks right through to complete fibre fracture must be feared, and their influence on attenuation can only be investigated in extensive practical tests such as those carried out by igus®.

The excellent test results, shown in part here, of the chainflex® -cabes must not be taken for granted, as investigations of fibre-optic cables from other manufacturers showed, some of which even failed with complete breaks in the fibres. The investigations revealed that chainflex® fibre-optic cables are not influenced in their function by mechanical loads such as tensile, transverse or bending stresses in energy chains®. Therefore they are perfectly suitable for use in the sometimes rough industrial environments for the interference-proof transfer of information between drive and control elements of machines. Bibliography: [1] Plastic fibre-optic cables for flexible Energy supply systems: Bernfried Späth, Frank Blase

Product information FOC Page 278 39


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:49 Seite 40

Example 6: tested! Selection from test results

Example 7: tested! EMC tests

Since 1989, we have been working on the development of electrical cables.

The "electromagnetic compatibility" of chainflex® cables

Back then, many of our customers lost their faith in the solution with energy supply systems because the cables being used frequently failed. Core breakage, "corkscrews", jacket wear and breakage of the shields were substantial reasons for these failures. Our chainflex® product range was then created from this situation of emergency. And due to the fact that we knew very little about cables at that time, we had only one choice: Testing, testing, testing, testing, testing.

Accordingly, we have since been making use of a firm principle: We almost always test our cables with a bending radius that is 30-50% less than the bending radius we mention in our catalog. We guarantee the quality requirement specified for our own products based on the production-process-accompanying sample tests that are carried out with at least 1 million reverse bending processes. During the subsequent inspection of the cable, this cable must be completely intact and, especially, none of the single wires must be broken. Newly developed types undergo considerably longer reverse bending processes in energy chains® before a new chainflex® series is released.

Extensive database Today, we have recourse to an extensive database with detailed information on the service life of our chainflex® cables which makes it possible for us to give you the information you need for your application.

The subject of "electromagnetic compatibility (EMC)" is becoming increasingly important. For one thing, this is due to a increase in the electromagnetic interference fields in the long-distance range caused in particular by modern telecommunications and communication technology as well as in the local range caused by energy technology.

On the other hand, the requirements for data transmission are also increasing. The signals are becoming more susceptible to interference and the electromagnetic environmental influencing factors more diverse. This can be especially problematic for the coupling between cables which, as is frequently the case in energy-conducting chains, are conducted on a parallel basis over a certain distance. A heavycurrent cable with interference acts as a producer of an electromagnetic interference field which, in turn, acts upon another cable, normally a signal cable, and then causes cableconducted interference there. Already several years ago, we therefore introduced electrical cables with fibre-optic cables made of glass that are also capable of being subjected to the mechanical stress in energy chains®. Even the chainflex® cables with conventional copper conductors were tested with respect to their electromagnetic compatibility in an extensive, application-oriented test program. An asynchronous motor, for example, was therefore connected via an unshielded heavy-current cable (chainflex® CF30) to a frequency converter. This frequency converter with pulse width modulation becomes the generator of new spectral shares never existing previously in the primary or secondary networks. On a parallel basis with this heavy-current, chainflex® cables were also kept available for digital signal transmission in energy chains®. Especially good results can be achieved here by the chainflex® CF12 cable which was specifically designed according to the EMC aspect. This cable possesses twisted-pair cores, the pairs of which are provided with a copper shield, as well as a total shield made of a steel braid in addition. Interference over a broad frequency range can therefore be effectively prevented as a result. The capacitive as well as the inductive coupling was also tested. In the case of the selected test conditions, it was determined that, even when the energy cables and signal cable touch one another over a longer distance, error-free data transmission is possible if a shielded chainflex® cable is used and this shield is grounded on both sides. In addition, tests were carried out in accordance with the existing standards on electromagnetic compatibility. These standards provide a general basis for determining the operating behavior of electrical devices that are repeatedly exposed to electrical interference. They were not introduced specifically for cables. In particular, tests with the "burst generator" were carried out. Here, fast transient interference signals are generated in pulse groups that simulate switching processes in particular. Such processes occur, e.g. during the interruption of inductive loads or during the bouncing of relay contacts. Here, too, the shielded chainflex® cables have proved their reliability.

Selection of test results from the igus®-own technical training center in Cologne for the year 2000. 40

Product information CF12 Page 124 41


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:50 Seite 42

Example 8: tested, tested! Fibre optic cables – run 76.000 km Go 76.000 km or 1,5 times round the world with chainflex® fibre optic cables. Users of data transmission systems (bus systems) with high data rates or long transmission lengths or even heavy EMC loads are relying on fibre optic cables more and more often. Many users today, however, are not conscious of the fact that the advantages that apply for fibre optic cables in general are even greater when chainflex® fibre optic cables are used in e-chains®. Data transmission systems on a copper basis usually have two basic disadvantages. 1. The maximum transmission lengths are greatly restricted by the transmission systems (between 5 and 50 m cable length depending on system and transmission frequency). 2. The copper-based cables used in moving energy supplies usually show an increase in attenuation values after some time at high cycle rates, which in turn have a negative effect on the maximum ranges. The case is completely different with data transmission or bus system-independent fibre optic cables made of glass. As well as being suitable for any transmission/bus system (providing the right converters are used), they have the following advantageous properties: 1. The transmission lengths are not restricted by the data transmission systems used and are – depending on the type of fibre optic cable used – several hundred metres long.

Test parameters: Test cable:

igus® chainflex® CFLG.2HG.MF.50/125

Number of fibres:

2

Type of fibre:

Gradient fibre 50/125µm

Connector:

2 x ST Connector

Travel:

2m

Length of cable:

3m

Energy supply:

igus® e-chain® series 15.015.100.0

Test radius:

11 x d

Product information CFLG.2H Page 150

The lightwave length considered here is 850 nm.

Increase in attenuation as a function of the number of individual strokes

Attenuation in [dB]

2. With chainflex® fibre optic cables, the increases in attenuation even at very high cycle rates in e-chains® are so low that the values are almost non-measurable, and most of the attenuation is to be found near the plug. The question of how greatly the attenuation behaviour of an igus® chainflex® fibre optic cable changes has been examined using the following test set-up, which had not been concluded as the catalogue went to press (in 4/08).

Taking into consideration that ST plugs have a mean insertion attenuation of 0,3 dB and a maximum insertion attenuation of 0,5 dB, the increase in attenuation of approx. 0,1-0,15 dB after more than 30 million movements in the e-chain® is absolutely negligible. Thus the cable has covered more than 76.000 km during the test.

Number of individual strokes in [MioH] Maximum permissible attenuation

43


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:50 Seite 44

Example 9: tested! Fast images Fast images in industrial applications: USB, FireWire The rising resolution and sampling rates of modern digital visual display systems are also inevitably accompanied by the rapid increase in the data quantities to be transmitted. Fast bus systems which find application for similar data quantities vailable in the consumer sector were taken from the industry particularly for this purpose.

Here the typical representatives are bus systems such as FireWire (1394a and 1394b), USB (2.0), as well as Gigabit Ethernet or CameraLink. All these bus systems need special cables, which are offered in the consumer sector by numerous manufacturers at knocked-down prices. Many of these frequently preassembled cables are developed and manufactured only for static laying or minor mechanical stressing. Costly production losses would be inescapable, if such cables were used in industrial applications with all the known parameters such as chemicals, electro-magnetic and mechanical load, etc. These are not only "genuine" downtimes such as wire breakage or short circuits of the litz wires, but errors can be noticed gradually through alteration of the capacitive features with a reduction of the possible transmission rates and increased dampening. The use of substandard materials and a deficient mechanical structure in fibre optic cables can lead to murkiness of the fibres and thus also to reduced data rates. A genuine troubleshooting in bus cables is possible only with very expensive equipment and lots of time. Depending on the position of the damage, the errors may also occur only sporadically during operation and cannot be found once the facility stops. The good experiences in thousands of applications with classic field bus systems, e.g. Profibus, Interbus, DeviceNet, etc., and the desire of many customers for comparable cables also for the above-mentioned high-speed bus systems led igus® to develop an own cable series, among others, with the following cable types: n CFBUS.055 for FireWire 1394a n CFBUS.065 and CFBUS.066 USB 2.0

In the industrial environment, it is not only the electrical and mechanical features that play a role, but also the resistance to a great variety of media such as oils, coolants or the like. The seasoned outer jacket material TPE has already proved its durability in many thousands of applications in other igus® cables.

Several industrial cameras traversed on a fast linear motor at a speed of 2 m/s, an acceleration of 5 m/s and a travel of 600 mm, while the bus cables moved continuously in the used e-chainsystems®.

All cables are subject to ample tests in the igus® laboratory; as there is no existing conclusive test procedure, the igus® engineers chose a very pragmatic method.

Test rig:

Stranded strain relief elements

Gel-filled, armored fibre sheath

n CFLG.2HG.MF. Fibre optic cable series for bus-

10 m CFBUS.055 FireWire (1394a) tested in an e-chain® of the B10.015.125 series with over 6 million movements with a FireWire 1394a camera. 10 m CFBUS.066 (USB 2.0) tested in an e-chain® of the B10.015.100 series with over 3,5 million movements with a USB 2.0 camera. 10 m CFLG.2HG.MF.50/125 tested in an e-chain® of the B10.015.075 series with over 3 million movements with a Fire-Wire 1394b camera with optical output.

independent, long transmission stretches The main focus in the development was on mechanically stable cable designs in order to grant the capacitive, inductive and optical features over a high number of cycles.

44

Product information Page 266

In the mechanical structure of the shields as well, a long service life was aimed at by material selection and special manufacturing processes.

Gusset-filled extruded PUR jacket

Despite the long cable lengths, particularly in USB and FireWire, no adverse effects on the picture quality could be determined even according to this stroke rate. This non-scientific, but practice-oriented test distinctly proves the industrial capability of these high-speed bus cables.

Cross section "chainflex®" fibre optic cable from igus®.

This test is not complete and is continuing.

45


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:51 Seite 46

Example 10: tested! Light in the cold Light in the cold – igus® gradient fibre glass cable in the deep freeze test In the safe transmission of large amounts of data in bus systems at high speeds over long distances, the igus® gradient fibre glass cable of the type CFLG.G has already become a standard in numerous applications in cranes. Insensitivity to electro-magnetic load and resistance to hard environmental influences enable the application together with energy supply cables in very long travels.

Varied and extreme temperature curves thereby served for the simulation of environmental influences, particularly when the temperature plunged during downtimes from plus degrees to -40 °C in the shortest time and the motion was restarted afterward. Under these application conditions, the dampening of the cable also should not rise above 3 dB at 850 nm wave length. After one million double strokes, which correspond to an operational performance of about 7000 kilometres, the maximum dampening is reached and still remains significantly below 3 dB. The measurements highlighted in the diagram reveal that distinct variations in temperature combined with the constant movement in the e-chain® have only minor effects on the dampening of the CFLG.6G.TC cable. The noticeable high initial dampening is attributed to the plugs used and also reflects the reality here because, in practice, 90 % of the cables used in automation are pluggable fibre optic cables.

Product information CFLG.G Page 158

The test with the igus® cable makes it quite clear that only realistic and absolutely very expensive tests can fetch clarity about the service life of cables.

What happens in crane facilities in regions with extremely low temperatures? Does the maximum possible cable length of several hundred metres reduce through increase in dampening at low temperatures, or does the cable break in extreme applications, for example at -40 °C?

As no precise statement about this topic could be found in relevant technical journals, and as little was known particularly about the thermal features of the gel, igus®, as part of its philosophy, undertook own tests to determine the reliable specifications for applications in e-chainsystems®. For this task, the igus® test laboratory was equipped with a freezer that can generate constant temperatures of -40 °C and a test facility was mounted for long travels up to 7 m for a speed of 1,6 m/s and an acceleration up to 6 m/s. The igus® gradient fibre glass cable CFLG.6G.50/125.TC was tested. The cable was tested with a length of about 15 m as loop in an igus® e-chainsystem® 3500.125.200.0 with a radius of 200 mm. 46

Fibre no. 1, direction 1

Dampening in [dB] at 850 nm

The sensitive glass fibres are conducted in a gel-filled hollow space. How does the gel behave in highly dynamic conditions and what happens in restarts after long downtimes?

Dampening of the fibres 1-6 of the CFLG.6G.50/125.T cable in two directions

Fibre no. 2, direction 1 Fibre no. 3, direction 1 Fibre no. 4, direction 1 Fibre no. 5, direction 1 Fibre no. 6, direction 1 Fibre no. 1, direction 2 Fibre no. 2, direction 2 Fibre no. 3, direction 2 Fibre no. 4, direction 2 Fibre no. 5, direction 2 Fibre no. 6, direction 2

Temperature in °C (number of double strokes)

after 5 days after 5 days at rest at rest BEFORE AFTER restart restart

47


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:51 Seite 48

Example 11: tested! Completely turned chainflex® cables for e-chainsystem® are designed for application in linear movements and their efficiency has been proved a million times. But industrial applications and their necessary motion sequences become increasingly complex, so that special cables are more and more required for torsional movements. The service life of the most differing constructions are yet harder to calculate for torsion applications, as no fixed sizes such as radii, travels or the like, are defined. Shielded cables however are very difficult in torsion applications. Braided shields are generally braided in the opposite direction. Whether a cable maintains the torsional demands is very strongly dependent on the application and type of installation.

In torsional movements the shield litz wires are therefore drawn in one winding direction, and the other turned in the other winding direction. The woven arrangement and the entailing constriction of each winding direction lead to a quick breakage of the shield from the resulting expansion of the shield litz wires.

The new igus® development of a twistable, shielded singlecore cable picks up on this point and ensures, due to its special design and understucture of the shield, that no forces at all or that only the smallest possible forces act on the shield wire. As the described test clearly shows, massive service life extension can, for example, be determined when compared to a CF310.250.01. Test rig: The new cable CF ROBOT was tested at the igus® laboratory on a specially developed rig for torsion test. The torsion angle thereby amounts to ±270° for a total cable length of about 2,5 m (tested in different versions of the triflex® R).

Picture 1: damaged overall shield sample of the braid version after 250.000 movements.

Fitted for the test were: n 3 CF ROBOT cables 037 n 3 cables of the series CF310.250.01.UL n 3 cables of the series CF310.250.01

The detail inspection of the shield braid shows distinct damage on the shield wires.

The analyzed samples (Picture 2) of the CF ROBOT (so far samples were taken after 250.000, 1,5 million and 3 million movements). 037 show no damage in the area of the cable or the overall shield even at above 3 million torsional movements of ± 270°.

Unshielded cables, particularly all bundle-stranded chainflex® types, could be successfully used in many torsion applications.

Picture 2: The CF ROBOT shows absolutely no damage after more than 3 million movements.

The detailed analyses (Picture 3) of the shield wires, buffer fibres, PTFE film and the cable show no apparent wear outs. The test is carried out further to determine the maximum service life of the cable.

igus® test lab: The cables were tested in movements of ± 270°.

The initial test sample of the CF310 with braided shield and the CF ROBOT were taken after 250.000 movements with a torsion angle of ± 270°.

At igus®, the emphasis is not only on technology but also on beautifully designed products. The TRC and TRE series both received the iF-Design-Award. 48

Product information CF ROBOT Page 234

The analyses (cable taken apart) were undertaken in three part areas respectively of the cable length. In the sample illustrated in Picture 1, distinct damage to the overall shield are noticeable in the upper third of the cable taken apart.

Picture 3: detail pictures of the CF ROBOT after more than 3.0 million movements of ±270°.

49


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:52 Seite 50

Example 12: tested, tested, tested! Service life comparision Regular production inspections increase the operational reliability of machines. In addition to tests performed in the igus® in-house laboratory, where new superstructural parts, materials, and customer requirements are constantly being inspected, igus® also performs production-accompanying inspections. Next to batch tests, which immediately reveal any productionrelated defects and provide the user with maximum reliability, long-term inspections are performed again and again. These long-term inspections, which can take up to four years – and emphasize the effort and expenditure required for such series of systematic tests – are necessary if the constantly growing market demands are to be met.

This also applies to the long-term inspection of the chainflex® servo cable families CF21.UL and CF27.D. These servo cables, which are based on a modular system and only differ in their inner and outer jacket materials in terms of production details, were tested for more than 2,5 years at a radius of 100 mm, a travel distance of approx. 8 m, an acceleration of approx. 6 m/s2, and a velocity of approx. 3,5 m/s.

CF21.UL: overall stranding including the outer jacket without damage

CF27.D: overall stranding including the outer jacket without damage

CF21.40.10.02.01.UL: after more than 10 million bending movements, no shield wire breakages

CF27.40.10.02.01.D: after more than 10 million bending movements, no shield wire breakages

A core number / cross-section combination which is widely accepted in the field of mechanical engineering but also results in failures due to the extremely asymmetric setup in the case of many normal – so-called chain-suitable – cable superstructural parts was deliberately selected.

The test items, CF21.40.10.02.01.UL (4x4 mm2 + 2x1,0 mm2), and CF27.40.10.02.01.D (4x4 mm2 + 2x1,0 mm2), which were constantly monitored electrically during the test phase, were tested in continuous operation in a real chain-equipped system. Result: After more than 10 million individual strokes, the cables were disassembled into their individual parts and inspected. As can also be seen in the section photos, it was not possible to determine any wire breakages on the individual conductors or any changes on the insulations. Only slight traces of abrasion on the outer jacket – which cannot result in any limitation of functions – also show that the cable has completed a large number of strokes. Summary: The design philosophy, with gusset-filled extruded inner jacket and pressure-extruded outer jacket, clearly shows the long service life and definite advantages of these cables versus the commonly used cables most of which are designed with fillers and tapes.

50

Deliberately non-conforming chain filling in order to simulate a real application.

Product information CF21.UL Page 190 CF27.D Page 198

51


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:52 Seite 52

Example 13: tested live! Container crane at 50 m travel distance In the crane engineering industry, energy supply systems prove their technical and economic strengths more and more frequently. Flexibility, variability, and space-saving installation are only a few of the most important criteria. An important building block of an energy supply system has to do with the cables. Here, users expect a high degree of operational reliability. In the chainflex® laboratory, igus® cables undergo constant tests which can be used to obtain important information on the service life of a cable and to derive improvements for the future structural design of the cable. However, the situation becomes very exciting if you get the rare opportunity to remove cables from their real, tough applications and can inspect them.

Current inspection The chainflex® cable CF9.60.05 has been used in container cranes for many years; in the case presented here with a total travel distance of approx. 47 m. An inspection contract commissioned by the owner-operator was to present a performance balance sheet after more than 40.000 chain kilometres and determine the date from which the next preventive maintenance work for the other equipment should be taken into account. Following the removal of the CF9.60.05, inspections were performed with the following objectives: 1. outer jacket, abrasion behaviour, other damage; 2. overall stranding, insulation behaviour of the individual cores; 3. litz wire structural design, number of any possibly individual broken wires which might be an indication of an early failure of the entire cable.

The energy chain system® was filled with many different igus® chainflex® cables, e.g. the CF9.60.05 Result regarding 1: No or only barely measurable traces of abrasion could be detected on the highly abrasion-resistant TPE outer jacket. This means that a failure due to abrasion or jacket breakage despite extreme environmental factors (temperature differences, UV irradiation, etc.) is not to be expected. Result regarding 2: The overall stranding structure showed – due to the gussetfilled extruded outer jacket – no indications of fatigue and had not changed in its pitch length. Due to the large share of talc, no abrasion was determined between the TPE-insulated cores. The high-voltage tests also did not show any age-related changes.

An igus® energy supply system with an approx. length of 26 m in a stainless steel trough with middle band support.

Result regarding 3: The cable was opened all the way to the copper conductor in the most stressed section of the radius. Here too, after more than 40.000 km, the inspection of the individual wires also showed no fatigue breakages which would indicate an early failure of the cable. To sum up, it can be said that this cable, which was used in a real crane application in the second trolley of an STS crane, is still completely intact even after more than 40.000 km and that preventive repair work is not required.

An igus® energy supply system with a length of approx. 26 m in a stainless steel trough with middle band support.

52

Product information CF9 Page 90

The individual elements of the CF9 from the cable piece dissected for the test setup.

A close-up of the completely intact copper conductor. The inspection performed over the entire length shows that the conductor is still completely intact and does have any individual wire breakages.

53


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:52 Seite 54

Example 14: tested! Comparison of sheathing materials in different oils

Example 15: tested! Completely twisted, take two.

For years now, specially developed tests tailored to the individual requirements of igus® customers have been used to obtain more meaningful results than would be conceivable if standard tests were used. The relatively generalised terms such as "oil-resistant" or "coolant-resistant" are little help in making the right selection in terms of sheathing material to be used for an application with oil, lubricant or coolant influence.

The "torsion-resistant" requirement for cables for energy chains is not new, but is seldom defined exactly. So how is a statement such as "This cable is torsion-resistant up to ±180 °!" to be evaluated? This makes it all the more important to be able to deliver comparable and meaningful test results.

Alongside the generally applicable tests according to e.g. DIN EN 60811-2-1 and IEC 60811-1-1, "everyday application conditions" are simulated as realistically as possible in a test set-up specially matching our customers' requirements. Thus, for example, the test samples are mounted in an energy chain that moves into an "oil bath" and then back out of it again. There is direct and alternating contact between the outer sheath and the medium to be tested and the air surrounding the energy chain or cable – just as in a real application. After a test duration to be freely chosen or defined according to igus® standard, the test samples can be tested in terms of changes in material characteristics e.g. by comparing material strength, elongation at tear and swelling with the values noted before the test started.

This way, customers do not only get a statement referring to the different resistance of the various materials. In contrast to the material ageing otherwise common following the above-mentioned standards, an estimation of service life in the e-chain® application is also possible. If the test samples – such as the external cables depicted – do not achieve the prescribed test duration, we advise against use in the respective application.

In order to satisfy this requirement, the "torsion test bench" was developed according to igus® standard. Here, various cable types are twisted to a prescribed cable length of 1 metre, which also corresponds to the distance between the fixed points. The degree of torsion can be freely chosen, and is defined individually according to the requirement made on the test specimen, whereby the test standard is ±180 °. After a prescribed number of double strokes or a negative electrical or mechanical test result, the respective test specimen is dissected, and the type and position of any damage can be determined exactly. The first chainflex® CF ROBOT types were developed to series maturity on the basis of this igus® standard test.

Product information CFROBOT Page 234

Cracks in the outer sheathing of materials from competitors caused by the "use of oil" in e-chains®. The "torsion test bench" especially developed according to the igus® standard. 54

55


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:53 Seite 56

-5/ +70

6,8-7,5

-5/ +70

7,5-10

2

20

58

3

2

20

62

10

5

80

66

10

5

80

70

-35/ +80

3

2

20

74

7,5-15

-35/ +80

3

2

20

76

6,8-7,5

-35/ +80

10

5

80

78

6,8-7,5

-35/ +80

10

5

80

82

5

-20/ +80

10

5

80

86

5

-35/ +100

10

6

100

90

5

-35/ +100

10

6

100

94

5

-35/ +100

10

6

100

98

5

-35/ +100

10

6

100

102

4

-35/ +90

10

6

100

106

4

-35/ +90

10

6

100

108

Oil-resistant

3

Approvals and standards

Page

6,8-7,5

a max. [m/s2]

-5/ +70

v max. [m/s] gliding

7,5-15

v max. [m/s] unsupported

Temperatur moved from/to [°C] -5/ +70

Torsion resistant

Minimum bending radius, moved [factor x d] 7,5-10

Shield

Jacket

chainflex type chainflex® cable

Control cables

®

Control cables CF130.UL

PVC

CF140.UL

PVC

CF5

PVC

CF6

PVC

CF170.D

PUR

CF180

PUR

CF77.UL.D

PUR

CF78.UL

PUR

CF2

PUR

CF9

TPE

CF10

TPE

CF9.UL

TPE

CF10.UL

TPE

CF98

TPE

CF99

TPE

57


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:53 Seite 58

CF130.UL PVC 7,5-10xd

PVC Control cable CF130.UL

Class 4.2.1 (4 medium load requirements

● for medium load requirements ● PVC outer jacket ● flame-retardant

Conductor Core insulation

2 travel distance up to 50 m 1 no oil-resistance)

UL/CSA

Style 10493 and 20200, 300 V, 60 °C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

CF130.UL PVC 7,5-10xd

Fine-wire stranded conductor consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture.

Typical application area Core stranding

Core identification

Outer jacket

T/R moved

T/R fixed

Number of cores < 12: cores stranded in a layer with short pitch length. Number of cores ≥ 12: cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially lowtorsion structure. Cores < 0,5 mm2: Colour code in accordance with DIN 47100 Cores ≥ 0,5 mm2: cores black with white numerals, one core green-yellow Low-adhesion mixture on the basis of PVC, adapted to suit the requirements in energy chains® (following DIN VDE 0281 Part 5). Colour: Silver gray (similar to RAL 7001) -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2. +5 °C to +70 °C for use in energy chains® with > 50.000 cycles. Minimum bending radius 7,5 x d with < 10 m travel distance, minimum bending radius 10 x d with ≥ 10 m travel distance. -20 °C to +70 °C, minimum bending radius 5 x d

● ● ● ● ●

for medium load requirements without influence of oil preferably indoor applications especially for freely suspended travel distances, but also for gliding applications up to 50 m Wood/stone processing, packaging industry, supply system, handling, adjusting equipment

v max. 3 m/s, 2 m/s unsupported/gliding a max. 20 m/s2 Travel distance Torsion Nominal voltage

Freely suspended travel distances, but also for gliding applications up to 50 m, Class 2 ± 90 °, with 1 m cable length

Testing voltage

Number of cores < 12: 300/500 V Number of cores < 12 (0,25-0,34): 300/300 V Number of cores ≥ 12: 300/300 V (following DIN VDE 0245). 2000 V (following DIN VDE 0281-2).

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).

Image exemplary.

.

eplan download, configurator

www.igus.eu/en/CF130

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

chainflex® CF130.UL for woodworking. e-chain®: E4/light

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

59


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:53 Seite 60

CF130.UL PVC 7,5-10xd

PVC Control cable CF130.UL

Class 4.2.1 (4 medium load requirements

2 travel distance up to 50 m 1 no oil-resistance)

CF130.UL PVC 7,5-10xd

Image exemplary.

Delivery program Part No. CF130.02.03.UL CF130.02.04.UL CF130.02.06.UL CF130.02.07.UL CF130.02.12.UL CF130.02.20.UL CF130.02.25.UL CF130.02.30.UL CF130.03.02.UL CF130.03.05.UL CF130.05.02.UL CF130.05.03.UL CF130.05.04.UL CF130.05.05.UL CF130.05.07.UL CF130.05.12.UL CF130.05.18.UL CF130.05.25.UL CF130.07.02.UL CF130.07.03.UL CF130.07.04.UL CF130.07.05.UL CF130.07.07.UL CF130.07.12.UL CF130.07.18.UL CF130.07.25.UL CF130.07.36.UL(1) CF130.07.42.UL(1) CF130.10.02.UL CF130.10.03.UL CF130.10.04.UL CF130.10.05.UL CF130.10.07.UL CF130.10.12.UL CF130.10.18.UL CF130.10.25.UL

Number of cores and conductor nominal cross section [mm2] 3 x 0,25 4 x 0,25 6 x 0,25 7 x 0,25 12 x 0,25 20 x 0,25 25 x 0,25 30 x 0,25 2 x 0,34 5 x 0,34 2 x 0,5 3 G 0,5 4 G 0,5 5 G 0,5 7 G 0,5 12 G 0,5 18 G 0,5 25 G 0,5 2 x 0,75 3 G 0,75 4 G 0,75 5 G 0,75 7 G 0,75 12 G 0,75 18 G 0,75 25 G 0,75 36 G 0,75 42 G 0,75 2 x 1,0 3 G 1,0 4 G 1,0 5 G 1,0 7 G 1,0 12 G 1,0 18 G 1,0 25 G 1,0

External diameter approx. [mm] 4,5 5,5 6,0 6,5 8,5 10,5 11,5 12,5 4,5 5,5 5,5 6,0 6,5 7,0 8,0 9,5 12,0 13,5 6,0 6,5 7,0 7,5 8,5 10,5 13,0 15,5 19,0 20,5 6,0 7,0 7,5 8,0 9,0 11,5 14,0 17,0

Copper index [kg/km] 8 10 15 18 31 49 63 72 7 17 10 14 19 24 34 55 90 126 15 22 29 36 50 81 121 167 284 331 19 29 39 48 68 108 161 224

Weight [kg/km]

Delivery program Part No.

24 37 47 45 94 143 151 185 33 48 40 55 60 65 100 116 158 222 50 60 80 90 130 149 214 303 521 598 50 75 90 110 170 185 263 371

CF130.15.02.UL CF130.15.03.UL CF130.15.04.UL CF130.15.05.UL CF130.15.07.UL(17) CF130.15.12.UL CF130.15.18.UL CF130.15.25.UL CF130.15.36.UL(1) CF130.15.42.UL(1) CF130.25.03.UL CF130.25.04.UL CF130.25.07.UL(17) CF130.25.12.UL CF130.40.03.UL CF130.60.04.UL CF130.60.05.UL

External diameter approx. [mm] 7,5 7,0 8,0 8,5 10,5 13,0 16,5 19,5 23,5 25,5 8,5 9,5 13,0 16,0 11,0 13,5 15,0

Copper index [kg/km] 29 44 58 72 101 162 242 350 567 662 72 96 168 265 115 230 288

Weight [kg/km] 70 90 120 140 210 263 386 541 875 1017 116 180 350 406 200 360 418

New* New*

(17) Using the cables with "7 G 1,5 mm2" and "7 G 2,5 mm2" it is essential: bending radius 17 x d with travel distance ≥ 5 m. When the travel distance is not less than 5 m, a bending radius not less than 17 x d has to be used. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalog.

Order example: CF130.05.02.UL – in your desired length (0,5 m steps) CF130.UL chainflex series .05 Code nominal cross section .02 Number of cores ®

Please use www.chainflex.eu/en/CF130 for your online order. New* New*

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalog.

950 types from stock no cutting costs ... 60

Number of cores and conductor nominal cross section [mm2] 2 x 1,5 3 G 1,5 4 G 1,5 5 G 1,5 7 G 1,5 12 G 1,5 18 G 1,5 25 G 1,5 36 G 1,5 42 G 1,5 3 G 2,5 4 G 2,5 7 G 2,5 12 G 2,5 3 G 4,0 4 G 6,0 5 G 6,0

(for up to 10 cuts of the same type)

Available from stock. Delivery in 24h or today!* *Delivery time means time until shipping of goods.

eplan download, configurator

www.igus.eu/en/CF130

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

61


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:53 Seite 62

CF140.UL PVC 7,5-15xd

PVC Control cable CF140.UL ● ● ● ●

Class 4.2.1 (4 medium load requirements

for medium load requirements PVC outer jacket shielded flame-retardant

Conductor Core insulation Core stranding

Core identification

Inner jacket Overall shield Outer jacket

T/R moved

T/R fixed

Silicon-free

Fine-wire stranded conductor consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture. Number of cores < 12: cores stranded in a layer with short pitch length. Number of cores ≥ 12: cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially lowtorsion structure. Cores < 0,5 mm2: Colour code in accordance with DIN 47100 Cores ≥ 0,5 mm2: cores black with white numerals, one core green-yellow PVC mixture adapted to suit the requirements in energy chains®.

2 travel distance up to 50 m 1 no oil-resistance)

UL/CSA

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Style 10493 and 20200, 300 V, 60 °C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

CF140.UL PVC 7,5-15xd

Typical application area ● ● ● ● ●

for medium load requirements without influence of oil preferably indoor applications especially for freely suspended travel distances, but also for gliding applications up to 50 m Wood/stone processing, packaging industry, supply system, handling, adjusting equipment

Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical. Low-adhesion mixture on the basis of PVC, adapted to suit the requirements in energy chains® (following DIN VDE 0281 Part 5). Colour: Silver gray (similar to RAL 7001) -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2. +5 °C to +70 °C for use in energy chains® with > 50.000 cycles. Minimum bending radius 7,5 x d with < 10 m travel distance, minimum bending radius 15 x d with ≥ 10 m travel distance. -20 °C to +70 °C, minimum bending radius 7,5 x d

v max. 3 m/s, 2 m/s unsupported/gliding a max. 20 m/s2 Travel distance

Testing voltage

Freely suspended travel distances, but also for gliding applications up to 50 m, Class 2 Number of cores < 12: 300/500 V Number of cores < 12 (0,25-0,34): 300/300 V Number of cores ≥ 12: 300/300 V (following DIN VDE 0245). 2000 V (following DIN VDE 0281-2).

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Image exemplary.

Nominal voltage

eplan download, configurator

www.igus.eu/en/CF140

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

chainflex® CF140.UL for automatic feeder units. e-chain®: easychain®

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

63


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:53 Seite 64

CF140.UL PVC 7,5-15xd

PVC Control cable CF140.UL

Class 4.2.1 (4 medium load requirements

2 travel distance up to 50 m 1 no oil-resistance)

CF140.UL PVC 7,5-15xd

Image exemplary.

Delivery program Part No. CF140.02.12.UL CF140.03.05.UL CF140.05.03.UL CF140.05.05.UL CF140.05.18.UL CF140.05.36.UL CF140.07.03.UL CF140.07.04.UL CF140.07.05.UL CF140.07.07.UL CF140.07.12.UL CF140.07.18.UL CF140.07.25.UL CF140.07.36.UL CF140.07.42.UL(1) CF140.10.02.UL CF140.10.03.UL CF140.10.04.UL CF140.10.05.UL CF140.10.07.UL CF140.10.12.UL CF140.10.18.UL CF140.10.25.UL CF140.15.03.UL CF140.15.04.UL CF140.15.05.UL CF140.15.07.UL CF140.15.12.UL CF140.15.18.UL CF140.15.25.UL CF140.15.36.UL(1) CF140.15.42.UL(1) CF140.25.03.UL CF140.25.04.UL

Number of cores and conductor nominal cross section [mm2] (12 x 0,25)C (5 x 0,34)C (3 G 0,5)C (5 G 0,5)C (18 G 0,5)C (36 G 0,5)C (3 G 0,75)C (4 G 0,75)C (5 G 0,75)C (7 G 0,75)C (12 G 0,75)C (18 G 0,75)C (25 G 0,75)C (36 G 0,75)C (42 G 0,75)C (2 x 1,0)C (3 G 1,0)C (4 G 1,0)C (5 G 1,0)C (7 G 1,0)C (12 G 1,0)C (18 G 1,0)C (25 G 1,0)C (3 G 1,5)C (4 G 1,5)C (5 G 1,5)C (7 G 1,5)C (12 G 1,5)C (18 G 1,5)C (25 G 1,5)C (36 G 1,5)C (42 G 1,5)C (3 G 2,5)C (4 G 2,5)C

External diameter approx. [mm] 10,0 8,0 8,0 9,0 13,5 20,0 8,5 9,0 9,0 10,5 13,0 15,0 17,5 21,5 24,0 7,5 8,5 9,5 10,0 11,5 13,5 16,5 18,5 9,5 10,0 11,0 12,5 15,0 18,5 22,0 26,5 29,5 10,5 12,0

Copper index [kg/km] 69 42 37 52 130 273 48 57 66 84 130 179 256 397 444 33 44 55 77 107 162 227 322 69 89 105 135 215 339 480 683 803 98 174

Order example: CF140.10.04.UL – in your desired length (0,5 m steps) CF140.UL chainflex series .10 Code nominal cross section .04 Number of cores

Weight [kg/km] 111 80 87 130 232 493 90 130 150 170 220 289 414 726 792 84 130 150 170 200 243 407 481 150 180 220 260 407 467 703 1137 1345 171 250

®

Please use www.chainflex.eu/en/CF140 for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.

New* New*

New* New*

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalog.

eplan download, configurator

950 types from stock no cutting costs ... 64

(for up to 10 cuts of the same type)

www.igus.eu/en/CF140

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

65


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:53 Seite 66

CF5 PVC 6,8-7,5xd

PVC Control cable CF5 ● ● ● ●

Class 5.3.2 (5 high load requirements

for high load requirements PVC outer jacket oil-resistant flame-retardant

Strip cables 50% faster!

Testing voltage

2000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 50363-4-1), Class 2.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free

NFPA

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). < 0,5 mm2: Style 10492 and 2570, 600 V, 80 °C ≥ 0,5 mm2: Style 11113 and 2570, 600 V, 80 °C Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 2, material/cable tested by IPA according to ISO standard 14644-1

UL/CSA Conductor Core insulation

Core stranding

Core identification

Outer jacket

CFRIP T/R moved

T/R fixed

Fine-wire stranded conductor consisting of bare copper wires (following EN 60228). Cores < 0,5 mm2: Mechanically high-quality PP mixture. Cores ≥ 0,5 mm²: Mechanically high-quality PVC mixture (following DIN VDE 0207 Part 4). Number of cores < 12: cores stranded in a layer with short pitch length. Number of cores ≥ 12: cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially lowtorsion structure. Cores < 0,5 mm2: Colour code in accordance with DIN 47100 Cores ≥ 0,5 mm2: cores black with white numerals, one core green-yellow Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in energy chains® (following DIN VDE 0281 Part 13). Colour: Moss green (similar to RAL 6005) Strip cables 50% faster! The tear strip is in the outer jacket. Video www.igus.eu/en/CFRIP -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2. +5 °C to +70 °C for use in energy chains® with > 50.000 cycles. Minimum bending radius 6,8 x d with < 10 m travel distance, minimum bending radius 7,5 x d with ≥ 10 m travel distance. -20 °C to +70 °C, minimum bending radius 4 x d

3 travel distance up to 100 m 2 oil-resistant)

CF5 PVC 6,8-7,5xd

Typical application area ● ● ● ● ●

for high load requirements light oil influence preferably indoor applications, but also outdoor ones at temperatures > 5 °C especially for freely suspended and gliding travel distances up to 100 m Storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling, indoor cranes

Image exemplary.

v max. 10 m/s, 5 m/s unsupported/gliding a max. 80 m/s2 Travel distance

Freely suspended and gliding travel distances up to 100 m, Class 3

Torsion

± 90 °, with 1 m cable length

UV-resistant

Medium

Nominal voltage

300/500 V (following DIN VDE 0245).

eplan download, configurator

www.igus.eu/en/CF5

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

chainflex® CF5/CF6 for shelf control units: long travel in the longitudinal axis. e-chain®: Serie E4/00 with igus® guide trough out of steel

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

67


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:53 Seite 68

CF5 PVC 6,8-7,5xd

PVC Control cable CF5

Class 5.3.2 (5 high load requirements

3 travel distance up to 100 m 2 oil-resistant)

CF5 PVC 6,8-7,5xd

Strip cables 50% faster!

Image exemplary.

Delivery program Part No. CF5.02.36 CF5.03.15 CF5.03.18 CF5.03.25 CF5.05.02 CF5.05.03 CF5.05.05 CF5.05.07 CF5.05.12 CF5.05.18 CF5.05.25 CF5.05.30 CF5.07.03 CF5.07.04 CF5.07.05 CF5.07.07 CF5.07.12 CF5.07.18 CF5.07.25 CF5.07.36 CF5.07.42 CF5.10.03 CF5.10.04 CF5.10.05 CF5.10.07 CF5.10.12 CF5.10.18 CF5.10.25 CF5.15.03 CF5.15.04 CF5.15.05 CF5.15.07(17) CF5.15.12 CF5.15.18 CF5.15.25 CF5.15.36

Number of cores and conductor nominal cross section [mm2] 36 x 0,25 15 x 0,34 18 x 0,34 25 x 0,34 2 x 0,5 3 G 0,5 5 G 0,5 7 G 0,5 12 G 0,5 18 G 0,5 25 G 0,5 30 G 0,5 3 G 0,75 4 G 0,75 5 G 0,75 7 G 0,75 12 G 0,75 18 G 0,75 25 G 0,75 36 G 0,75 42 G 0,75 3 G 1,0 4 G 1,0 5 G 1,0 7 G 1,0 12 G 1,0 18 G 1,0 25 G 1,0 3 G 1,5 4 G 1,5 5 G 1,5 7 G 1,5 12 G 1,5 18 G 1,5 25 G 1,5 36 G 1,5

External diameter approx. [mm] 15,0 10,5 11,5 13,5 6,0 6,0 7,0 8,0 11,0 12,5 16,5 17,5 6,5 7,0 7,5 9,0 12,5 15,0 17,5 22,0 23,5 6,5 7,0 9,0 9,5 13,5 16,5 19,5 7,5 7,5 8,5 10,5 15,0 19,0 21,5 26,0

Copper index [kg/km] 95 52 64 88 10 15 24 34 58 86 121 144 22 29 36 50 86 130 181 259 302 29 39 48 68 116 173 241 44 58 72 101 173 260 361 518

Weight [kg/km] 275 135 175 235 34 42 72 77 158 230 310 402 63 72 85 108 240 322 432 564 610 62 85 100 145 260 450 590 95 120 170 220 320 550 810 980

(17) Using the cables with "7 G 1,5 mm2" and "7 G 2,5 mm2" it is essential: bending radius 17 x d with travel distance ≥ 5 m. When the travel distance is not less than 5 m, a bending radius not less than 17 x d has to be used. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 68

(for up to 10 cuts of the same type)

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] 4 G 2,5 5 G 2,5 7 G 2,5 12 G 2,5 18 G 2,5 25 G 2,5

CF5.25.04 CF5.25.05 CF5.25.07(17) CF5.25.12 CF5.25.18 CF5.25.25

External diameter approx. [mm] 11,5 12,5 14,5 23,5 27,5 32,5

Copper index [kg/km] 96 120 168 288 432 600

Weight [kg/km] 200 250 340 667 970 1366

(17) Using the cables with "7 G 1,5 mm2" and "7 G 2,5 mm2" it is essential: bending radius 17 x d with travel distance ≥ 5 m. When the travel distance is not less than 5 m, a bending radius not less than 17 x d has to be used. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF5.07.03 – in your desired length (0,5 m steps) CF5 chainflex series .07 Code nominal cross section .03 Number of cores ®

Please use www.chainflex.eu/en/CF5 for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.

eplan download, configurator

www.igus.eu/en/CF5

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

69


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:53 Seite 70

CF6 PVC 6,8-7,5xd

PVC Control cable CF6 ● ● ● ● ●

for high load requirements PVC outer jacket shielded oil-resistant flame-retardant

Class 5.3.2 (5 high load requirements Strip cables 50% faster!

Testing voltage

2000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 50363-4-1), Class 2.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free

NFPA

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). < 0,5 mm2: Style 10492 and 2570, 600 V, 80 °C ≥ 0,5 mm2: Style 11113 and 2570, 600 V, 80 °C Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1.

UL/CSA Conductor Core insulation

Core stranding

Core identification

Inner jacket Overall shield Outer jacket

CFRIP T/R moved

T/R fixed

Fine-wire stranded conductor consisting of bare copper wires (following EN 60228). Cores < 0,5 mm2: Mechanically high-quality PP mixture. Cores ≥ 0,5 mm²: Mechanically high-quality PVC mixture (following DIN VDE 0207 Part 4). Number of cores < 12: cores stranded in a layer with short pitch length. Number of cores ≥ 12: cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially lowtorsion structure. Cores < 0,5 mm2: Colour code in accordance with DIN 47100 Cores ≥ 0,5 mm2: cores black with white numerals, one core green-yellow PVC mixture adapted to suit the requirements in energy chains®. Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in energy chains® (following DIN VDE 0281 Part 13). Colour: Moss green (similar to RAL 6005) Strip cables 50% faster! The tear strip is in the outer jacket. Video www.igus.eu/en/CFRIP -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2. +5 °C to +70 °C for use in energy chains® with > 50.000 cycles. Minimum bending radius 6,8 x d with < 10 m travel distance, minimum bending radius 7,5 x d with ≥ 10 m travel distance. -20 °C to +70 °C, minimum bending radius 4 x d

3 travel distance up to 100 m 2 oil-resistant)

CF6 PVC 6,8-7,5xd

Typical application area ● ● ● ● ●

for high load requirements light oil influence preferably indoor applications, but also outdoor ones at temperatures > 5 °C especially for freely suspended and gliding travel distances up to 100 m Storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling, indoor cranes

v max. 10 m/s, 5 m/s unsupported/gliding a max. 80 m/s2

Image exemplary.

Travel distance UV-resistant

Freely suspended and gliding travel distances up to 100 m, Class 3 Medium

Nominal voltage

300/500 V (following DIN VDE 0245).

eplan download, configurator

www.igus.eu/en/CF6

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

chainflex® CF5 and CF6 control cable (green) as well as CF211 measuring system cable (grey) in a screwing station of a motor factory. e-chain®: System E4/00 with chainfix Clip Strain Relief Devices

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

71


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:53 Seite 72

CF6 PVC 6,8-7,5xd

PVC Control cable CF6

Class 5.3.2 (5 high load requirements

3 travel distance up to 100 m 2 oil-resistant)

CF6 PVC 6,8-7,5xd

Strip cables 50% faster!

Image exemplary.

Delivery program Part No. CF6.02.04 CF6.02.24(3) CF6.03.05 CF6.05.02 CF6.05.05 CF6.05.07 CF6.05.09 CF6.05.12 CF6.05.18 CF6.05.24(3) CF6.07.03 CF6.07.04 CF6.07.05 CF6.07.07 CF6.07.12 CF6.07.18 CF6.07.24(3) CF6.10.03 CF6.10.04 CF6.10.05 CF6.10.07 CF6.10.12 CF6.10.18 CF6.10.24(3) CF6.15.03 CF6.15.04 CF6.15.05 CF6.15.07 CF6.15.12 CF6.15.18 CF6.15.25 CF6.15.36 CF6.25.04

Number of cores and conductor nominal cross section [mm2] (4 x 0,25)C (24 x 0,25)C (5 x 0,34)C (2 x 0,5)C (5 G 0,5)C (7 G 0,5)C (9 G 0,5)C (12 G 0,5)C (18 G 0,5)C (24 G 0,5)C (3 G 0,75)C (4 G 0,75)C (5 G 0,75)C (7 G 0,75)C (12 G 0,75)C (18 G 0,75)C (24 G 0,75)C (3 G 1,0)C (4 G 1,0)C (5 G 1,0)C (7 G 1,0)C (12 G 1,0)C (18 G 1,0)C (24 G 1,0)C (3 G 1,5)C (4 G 1,5)C (5 G 1,5)C (7 G 1,5)C (12 G 1,5)C (18 G 1,5)C (25 G 1,5)C (36 G 1,5)C (4 G 2,5)C

External diameter approx. [mm] 7,5 14,0 8,0 7,0 8,5 10,0 11,5 13,0 15,0 17,5 8,0 8,5 9,0 10,5 14,0 17,5 19,5 8,5 9,0 9,5 12,0 15,0 19,0 21,0 9,0 10,0 10,0 12,0 17,0 21,5 23,5 30,0 13,0

Copper index [kg/km] 31 122 41 31 48 63 77 93 120 190 52 54 73 93 138 204 250 61 75 87 113 171 261 307 81 85 106 153 232 367 492 630 135

Weight [kg/km] 72 265 106 65 114 142 180 206 276 405 110 120 150 190 264 410 466 103 115 170 217 313 470 588 155 170 190 270 411 637 819 1241 275

Order example: CF6.15.12 – in your desired length (0,5 m steps) CF6 chainflex series .15 Code nominal cross section .12 Number of cores ®

Please use www.chainflex.eu/en/CF6 for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.

The chainflex® types marked with a (3) refer to cables that are based on a bundling of 4 cores each. Due to their excellent electrical properties (star-quad with especially minimum crosstalk), these cables can virtually be used in all cases in which otherwise twisted-pair cables are required. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

eplan download, configurator

950 types from stock no cutting costs ... 72

(for up to 10 cuts of the same type)

www.igus.eu/en/CF6

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

73


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:53 Seite 74

CF170.D PUR 7,5-10xd

PUR Control cable CF170.D ● ● ● ● ●

Class 4.1.3 (4 medium load requirements

for medium load requirements PUR outer jacket oil-resistant and coolant-resistant PVC-free/halogen-free low-temperature-flexible

1 freely suspended 3 oil-resistant)

DESINA

According to VDW, DESINA standardisation

Lead free

Following 2011/55/EU (RoHS-II)

CF170.D PUR 7,5-10xd

Typical application area

Conductor Core insulation

Fine-wire stranded conductor consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture.

Core stranding

Cores stranded in layers with short pitch length.

Core identification

Cores black with white numerals, one core green-yellow.

Outer jacket

Low-adhesion mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Window gray (similar to RAL 7040) -35 °C to +80 °C, minimum bending radius 7,5 x d with < 10 m travel distance; minimum bending radius 10 x d with ≥ 10 m travel distance -40 °C to +80 °C, minimum bending radius 5 x d

T/R moved

T/R fixed

v max. 3 m/s, 2 m/s unsupported/gliding a max. 20 m/s2 Travel distance

Freely suspended travel distances, Class 1

UV-resistant

Medium

Nominal voltage

300/500 V (following DIN VDE 0245).

Testing voltage

2000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

Offshore

MUD-resistant following NEK 606 – status 2009.

Silicon-free Halogen-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

CE

Following 2006/95/EG

● ● ● ● ●

for medium load requirements almost unlimited resistance to oil indoor and outdoor applications without direct sun radiation especially for freely suspended travel distances, but also for gliding applications up to 20 m Machining units/machine tools, low temperature applications

Delivery program Part No. CF170.05.12.D CF170.05.18.D CF170.05.30.D CF170.07.03.D CF170.07.05.D CF170.07.07.D CF170.07.12.D CF170.07.18.D CF170.07.20.D CF170.10.03.D CF170.10.04.D CF170.10.05.D CF170.10.07.D CF170.10.12.D CF170.10.18.D CF170.10.25.D CF170.15.03.D CF170.15.04.D CF170.15.05.D CF170.15.07.D(17) CF170.15.12.D CF170.15.18.D CF170.15.25.D CF170.25.04.D CF170.25.05.D CF170.25.07.D(17) CF170.40.04.D CF170.60.04.D CF170.100.04.D

Number of cores and conductor nominal cross section [mm2] 12 G 0,5 18 G 0,5 30 G 0,5 3 G 0,75 5 G 0,75 7 G 0,75 12 G 0,75 18 G 0,75 20 G 0,75 3 G 1,0 4 G 1,0 5 G 1,0 7 G 1,0 12 G 1,0 18 G 1,0 25 G 1,0 3 G 1,5 4 G 1,5 5 G 1,5 7 G 1,5 12 G 1,5 18 G 1,5 25 G 1,5 4 G 2,5 5 G 2,5 7 G 2,5 4 G 4,0 4 G 6,0 4 G 10,0

External diameter approx. [mm] 9,0 11,5 14,0 6,5 7,5 8,5 10,0 12,5 13,5 7,0 7,5 8,0 9,5 10,5 13,5 16,0 7,5 8,0 8,5 10,5 13,0 15,0 19,0 10,0 10,5 13,0 12,0 14,0 18,0

Copper index [kg/km] 58 86 144 22 36 50 86 130 144 29 37 48 67 118 173 240 43 58 68 101 173 259 360 96 114 168 154 230 384

Weight [kg/km] 125 180 280 50 70 100 160 230 288 55 61 85 130 170 290 390 72 90 106 180 270 390 540 150 177 280 220 320 530

Image exemplary.

(17) Using the cables with "7 G 1,5 mm2" and "7 G 2,5 mm2" it is essential: bending radius 17 x d with travel distance ≥ 5 m. When the travel distance is not less than 5 m, a bending radius not less than 17 x d has to be used. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

eplan download, configurator

www.igus.eu/en/CF170D

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

75


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:53 Seite 76

CF180 PUR 7,5-15xd

PUR Control cable CF180 ● ● ● ● ● ●

Class 4.1.3 (4 medium load requirements

for medium load requirements PUR outer jacket shielded oil-resistant and coolant-resistant PVC-free/halogen-free low-temperature-flexible

1 freely suspended 3 oil-resistant)

Halogen-free

Following EN 50267-2-1.

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

CF180 PUR 7,5-15xd

Typical application area Conductor Core insulation

Fine-wire stranded conductor consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture.

Core stranding

Cores stranded in layers with short pitch length.

Core identification

Cores black with white numerals, one core green-yellow.

Inner jacket

PUR mixture adapted to suit the requirements in energy chains®.

Overall shield

Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical. Low-adhesion mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Window gray (similar to RAL 7040) -35 °C to +80 °C, minimum bending radius 7,5 x d with < 10 m travel distance; minimum bending radius 15 x d with ≥ 10 m travel distance -40 °C to +80 °C, minimum bending radius 7,5 x d

Outer jacket

T/R moved

T/R fixed

v max. 3 m/s, 2 m/s unsupported/gliding a max. 20 m/s2 Travel distance

Freely suspended travel distances, Class 1

UV-resistant

Medium

Nominal voltage

300/500 V (following DIN VDE 0245).

Testing voltage

2000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

● ● ● ● ●

for medium load requirements almost unlimited resistance to oil indoor and outdoor applications without direct sun radiation especially for freely suspended travel distances, but also for gliding applications up to 20 m Machining units/machine tools, low temperature applications

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] (18 G 0,5)C (3 G 0,75)C (5 G 0,75)C (12 G 0,75)C (18 G 0,75)C (5 G 1,0)C (18 G 1,0)C (3 G 1,5)C (4 G 1,5)C (7 G 1,5)C (4 G 2,5)C (5 G 2,5)C (7 G 2,5)C

CF180.05.18 CF180.07.03 CF180.07.05 CF180.07.12 CF180.07.18 CF180.10.05 CF180.10.18 CF180.15.03 CF180.15.04 CF180.15.07 CF180.25.04 CF180.25.05 CF180.25.07

External diameter approx. [mm] 11,5 7,5 8,5 11,5 13,5 9,5 14,0 8,5 9,0 11,5 10,5 12,5 14,5

Copper index [kg/km] 121 40 61 133 176 75 238 67 85 146 130 165 225

Weight [kg/km] 200 71 95 186 255 120 317 104 129 202 179 218 295

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF180.07.05 – in your desired length (0,5 m steps) CF180 chainflex series .07 Code nominal cross section .05 Number of cores ®

Please use www.chainflex.eu/en/CF180 for your online order. Delivery time 24h or today.

Image exemplary.

Delivery time means time until shipping of goods.

Offshore

MUD-resistant following NEK 606 – status 2009.

Silicon-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).

eplan download, configurator

www.igus.eu/en/CF180

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

77


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:53 Seite 78

CF77.UL.D PUR 6,8-7,5xd

PUR Control cable CF77.UL.D ● ● ● ● ● ●

Class 5.3.3 (5 high load requirements

for high load requirements PUR outer jacket oil-resistant and coolant-resistant flame-retardant notch-resistant PVC-free/halogen-free

Conductor Core insulation Core stranding

Core identification

Outer jacket

T/R moved

T/R fixed

Fine-wire stranded conductor consisting of bare copper wires (following EN 60228) Mechanically high-quality TPE mixture. Number of cores < 12: cores stranded in a layer with short pitch length. Number of cores ≥ 12: cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially lowtorsion structure. Cores < 0,5 mm2: Colour code in accordance with DIN 47100 Cores ≥ 0,5 mm2: cores black with white numerals, one core green-yellow CF77.UL.03.04.INI: brown, blue, black, white Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Window gray (similar to RAL 7040) CF77.UL.03.04.INI: Colour: Colza yellow (similar to RAL 1021) -35 °C to +80 °C, minimum bending radius 6,8 x d with < 10 m travel distance, minimum bending radius 7,5 x d with ≥ 10 m travel distance -40 °C to +80 °C, minimum bending radius 4 x d

3 travel distance up to 100 m 3 oil-resistant)

CF77.UL.D PUR 6,8-7,5xd

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

Offshore

MUD-resistant following NEK 606 – status 2009.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free Halogen-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992) Following EN 50267-2-1

UL/CSA

Style 10493 and 20233, 300 V, 80 °C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

DESINA

According to VDW, DESINA standardisation

Lead free

Following 2011/55/EU (RoHS-II)

Typical application area ● ● ● ● ●

for high load requirements almost unlimited resistance to oil indoor and outdoor applications with average sun radiation especially for freely suspended and gliding travel distances up to 100 m Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling, refrigerating sector

v max. 10 m/s, 5 m/s unsupported/gliding a max. 80 m/s2 Travel distance

Freely suspended and gliding travel distances up to 100 m, Class 3

Torsion

± 180 °, with 1 m cable length

UV-resistant

Medium

Nominal voltage

Number of cores < 12: 300/500 V Number of cores < 12 (0,25-0,34): 300/300 V Number of cores ≥ 12: 300/300 V (following DIN VDE 0245) 2000 V (following DIN VDE 0281-2)

Image exemplary.

Testing voltage

eplan download, configurator

www.igus.eu/en/CF77

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

79


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:53 Seite 80

CF77.UL.D PUR 6,8-7,5xd

PUR Control cable CF77.UL.D

Class 5.3.3 (5 high load requirements

3 travel distance up to 100 m 3 oil-resistant)

CF77.UL.D PUR 6,8-7,5xd

Image exemplary.

Delivery program Part No. CF77.UL.02.04.D CF77.UL.03.04.INI CF77.UL.05.04.D CF77.UL.05.05.D CF77.UL.05.07.D CF77.UL.05.12.D CF77.UL.05.18.D CF77.UL.05.25.D CF77.UL.05.30.D CF77.UL.07.03.D CF77.UL.07.04.D CF77.UL.07.05.D CF77.UL.07.07.D CF77.UL.07.12.D CF77.UL.07.18.D CF77.UL.07.20.D CF77.UL.07.36.D CF77.UL.07.42.D(1) CF77.UL.10.02.D CF77.UL.10.03.D CF77.UL.10.04.D CF77.UL.10.05.D CF77.UL.10.07.D CF77.UL.10.12.D CF77.UL.10.18.D CF77.UL.10.25.D CF77.UL.15.03.D CF77.UL.15.04.D CF77.UL.15.05.D CF77.UL.15.07.D(17) CF77.UL.15.12.D CF77.UL.15.18.D CF77.UL.15.25.D CF77.UL.15.36.D(1) CF77.UL.15.42.D(1)

Number of cores and conductor nominal cross section [mm2] 4 x 0,25 4 x 0,34 4 G 0,5 5 G 0,5 7 G 0,5 12 G 0,5 18 G 0,5 25 G 0,5 30 G 0,5 3 G 0,75 4 G 0,75 5 G 0,75 7 G 0,75 12 G 0,75 18 G 0,75 20 G 0,75 36 G 0,75 42 G 0,75 2 x 1,0 3 G 1,0 4 G 1,0 5 G 1,0 7 G 1,0 12 G 1,0 18 G 1,0 25 G 1,0 3 G 1,5 4 G 1,5 5 G 1,5 7 G 1,5 12 G 1,5 18 G 1,5 25 G 1,5 36 G 1,5 42 G 1,5

External diameter approx. [mm] 5,5 6,0 6,0 6,5 7,5 10,0 12,0 13,5 14,5 6,0 6,5 7,0 8,5 11,5 13,5 14,0 19,0 20,5 6,0 6,5 7,0 7,5 8,5 11,5 14,5 17,0 7,0 7,5 8,0 10,0 14,0 17,0 19,5 23,5 25,5

Copper index [kg/km] 10 15 19 24 37 57 86 119 143 21 28 35 49 84 126 140 284 331 20 29 39 49 68 116 174 240 42 55 69 96 165 260 360 567 662

Weight [kg/km] 34 38 48 55 76 128 188 244 297 52 61 71 100 183 247 277 497 570 52 61 75 91 112 222 321 406 81 99 117 164 290 397 555 837 973

Delivery program Part No.

New*

New*

External diameter approx. [mm] 8,5 9,0 10,5 12,5 11,5

Copper index [kg/km] 80 91 120 168 154

Weight [kg/km] 108 145 179 253 242

New*

(1) Delivery time upon inquiry. (17) Using the cables with "7 G 1,5 mm2" and "7 G 2,5 mm2" it is essential: bending radius 17 x d with travel distance ≥ 5 m. When the travel distance is not less than 5 m, a bending radius not less than 17 x d has to be used. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalogue.

Order example: CF77.UL.10.03.D – in your desired length (0,5 m steps) CF77.UL.D chainflex series .10 Code nominal cross section .03 Number of cores ®

Please use www.chainflex.eu/en/CF77 for your online order. Delivery time 24h or today. New*

Delivery time means time until shipping of goods.

New* New*

(1) Delivery time upon inquiry. (17) Using the cables with "7 G 1,5 mm2" and "7 G 2,5 mm2" it is essential: bending radius 17 x d with travel distance ≥ 5 m. When the travel distance is not less than 5 m, a bending radius not less than 17 x d has to be used. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalogue.

950 types from stock no cutting costs ... 80

CF77.UL.25.03.D CF77.UL.25.04.D CF77.UL.25.05.D CF77.UL.25.07.D(17) CF77.UL.40.04.D(1)

Number of cores and conductor nominal cross section [mm2] 3 G 2,5 4 G 2,5 5 G 2,5 7 G 2,5 4 G 4,0

(for up to 10 cuts of the same type)

eplan download, configurator

www.igus.eu/en/CF77

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

81


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:53 Seite 82

CF78.UL PUR 6,8-7,5xd

PUR Control cable CF78.UL ● ● ● ● ● ● ●

Class 5.3.3 (5 high load requirements

for high load requirements PUR outer jacket shielded oil-resistant and coolant-resistant flame-retardant notch-resistant PVC-free/halogen-free

Conductor Core insulation Core stranding

Core identification

Inner jacket

Fine-wire stranded conductor consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture. Number of cores < 12: cores stranded in a layer with short pitch length. Number of cores ≥ 12: cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially lowtorsion structure. Cores < 0,5 mm2: Colour code in accordance with DIN 47100 Cores ≥ 0,5 mm2: cores black with white numerals, one core green-yellow PUR mixture adapted to suit the requirements in energy chains®.

3 travel distance up to 100 m 3 oil-resistant)

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

Offshore

MUD-resistant following NEK 606 – status 2009.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free Halogen-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1

UL/CSA

Style 10493 and 20233, 300 V, 80 °C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

CF78.UL PUR 6,8-7,5xd

Typical application area Overall shield Outer jacket

T/R moved

T/R fixed

Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Window gray (similar to RAL 7040) -35 °C to +80 °C, minimum bending radius 6,8 x d with < 10 m travel distance, minimum bending radius 7,5 x d with ≥ 10 m travel distance -40 °C to +80 °C, minimum bending radius 4 x d

● ● ● ● ●

for high load requirements almost unlimited resistance to oil indoor and outdoor applications with average sun radiation especially for freely suspended and gliding travel distances up to 100 m Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling, refrigerating sector

v max. 10 m/s, 5 m/s unsupported/gliding a max. 80 m/s2 Travel distance

Freely suspended and gliding travel distances up to 100 m, Class 3

UV-resistant

Medium

Nominal voltage

Number of cores < 12: 300/500 V Number of cores < 12 (0,25-0,34): 300/300 V Number of cores ≥ 12: 300/300 V (following DIN VDE 0245) 2000 V (following DIN VDE 0281-2).

Image exemplary.

Testing voltage

eplan download, configurator

www.igus.eu/en/CF78

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

83


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:54 Seite 84

CF78.UL PUR 6,8-7,5xd

PUR Control cable CF78.UL

Class 5.3.3 (5 high load requirements

3 travel distance up to 100 m 3 oil-resistant)

CF78.UL PUR 6,8-7,5xd

Image exemplary.

Delivery program Part No. CF78.UL.05.04 CF78.UL.05.05 CF78.UL.05.07 CF78.UL.05.09 CF78.UL.05.12 CF78.UL.05.18 CF78.UL.05.25 CF78.UL.07.03 CF78.UL.07.04 CF78.UL.07.05 CF78.UL.07.07 CF78.UL.07.12 CF78.UL.07.18(1) CF78.UL.07.36 CF78.UL.07.42(1) CF78.UL.10.03 CF78.UL.10.04 CF78.UL.10.05 CF78.UL.10.07 CF78.UL.10.12 CF78.UL.10.18(1) CF78.UL.10.25 CF78.UL.15.03 CF78.UL.15.04 CF78.UL.15.05 CF78.UL.15.07 CF78.UL.15.12 CF78.UL.15.18 CF78.UL.15.25 CF78.UL.15.36(1) CF78.UL.15.42(1) CF78.UL.25.04 CF78.UL.25.05(1) CF78.UL.25.07 CF78.UL.40.04(1)

Number of cores and conductor nominal cross section [mm2] (4 G 0,5)C (5 G 0,5)C (7 G 0,5)C (9 G 0,5)C (12 G 0,5)C (18 G 0,5)C (25 G 0,5)C (3 G 0,75)C (4 G 0,75)C (5 G 0,75)C (7 G 0,75)C (12 G 0,75)C (18 G 0,75)C (36 G 0,75)C (42 G 0,75)C (3 G 1,0)C (4 G 1,0)C (5 G 1,0)C (7 G 1,0)C (12 G 1,0)C (18 G 1,0)C (25 G 1,0)C (3 G 1,5)C (4 G 1,5)C (5 G 1,5)C (7 G 1,5)C (12 G 1,5)C (18 G 1,5)C (25 G 1,5)C (36 G 1,5)C (42 G 1,5)C (4 G 2,5)C (5 G 2,5)C (7 G 2,5)C (4 G 4,0)C

External diameter approx. [mm] 8,0 8,5 9,5 10,5 12,5 14,0 16,0 8,0 8,5 9,5 10,5 13,5 15,5 21,5 24,0 8,5 9,0 9,5 11,0 14,5 17,0 19,5 9,5 10,0 10,5 12,5 15,5 19,0 22,5 26,5 29,5 11,5 12,5 14,5 15,0

Copper index [kg/km] 32 38 56 68 88 125 163 35 47 57 77 125 175 397 444 48 58 71 94 155 220 315 65 80 98 131 215 307 495 683 803 123 150 207 189

Order example: CF78.UL.15.18 – in your desired length (0,5 m steps) CF78.UL chainflex series .15 Code nominal cross section .18 Number of cores

Weight [kg/km] 77 88 117 144 198 268 349 82 94 119 153 252 337 691 755 101 116 137 179 299 412 535 126 145 172 225 370 511 710 1082 1279 205 245 330 322

®

Please use www.chainflex.eu/en/CF78 for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.

New* New*

New* New* New* New*

(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalogue.

950 types from stock no cutting costs ... 84

(for up to 10 cuts of the same type)

eplan download, configurator

www.igus.eu/en/CF78

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

85


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:54 Seite 86

CF2 PUR 5xd

PUR Control cable CF2 ● ● ● ● ● ● ●

Class 6.3.3 (6 maximum load requirements

for maximum load requirements PUR outer jacket shielded oil-resistant and coolant-resistant flame-retardant notch-resistant hydrolysis-resistant and microbe-resistant

Conductor Core insulation

Core stranding

Core identification

Inner jacket Overall shield

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Cores < 0,5 mm2: Mechanically high-quality PP mixture. Cores ≥ 0,5 mm²: Mechanically high-quality PVC mixture (following DIN VDE 0207 Part 4). Number of cores < 12: cores stranded in a layer with short pitch length. Number of cores ≥ 12: cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially lowtorsion structure. Cores < 0,5 mm2: Colour code in accordance with DIN 47100 Cores ≥ 0,5 mm2: cores black with white numerals, one core green-yellow PVC mixture adapted to suit the requirements in energy chains®.

T/R moved

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Anthracite gray (similar to RAL 7016) -20 °C to +80 °C, minimum bending radius 5 x d

T/R fixed

-40 °C to +80 °C, minimum bending radius 4 x d

Outer jacket

3 travel distance up to 100 m 3 oil-resistant)

Offshore

MUD-resistant following NEK 606 – status 2009.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free

NFPA

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). < 0,5 mm2: Style 10493 and 20317, 300 V, 80 °C ≥ 0,5 mm2: Style 1007 and 20317, 300 V, 80 °C Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

UL/CSA

CF2 PUR 5xd

Typical application area ● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil Indoor and outdoor applications especially for freely suspended and gliding travel distances up to 100 m Storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling, indoor cranes, refrigerating sector

v max. 10 m/s, 5 m/s unsupported/gliding a max. 80 m/s2

Image exemplary.

Travel distance UV-resistant

Freely suspended and gliding travel distances up to 100 m, Class 3 High

Nominal voltage

300/500 V (following DIN VDE 0245).

Testing voltage

2000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

eplan download, configurator

www.igus.eu/en/CF2

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

chainflex® cables are resistant to oil and coolants. e-chain®: System E4/00

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

87


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:54 Seite 88

CF2 PUR 5xd

PUR Control cable CF2

Class 6.3.3 (6 maximum load requirements

3 travel distance up to 100 m 3 oil-resistant)

CF2 PUR 5xd

Image exemplary.

Delivery program Part No. CF2.01.04 CF2.01.08 CF2.01.12 CF2.01.18 CF2.01.24(3) CF2.01.36 CF2.01.48 CF2.02.04 CF2.02.08 CF2.02.18 CF2.02.24(3) CF2.02.48 CF2.05.12(1) CF2.05.18(1) CF2.07.04(1) CF2.07.12(1) CF2.07.24(3)/(1) CF2.10.05(1) CF2.10.24(1) CF2.15.03(1)

Number of cores and conductor nominal cross section [mm2] (4 x 0,14)C (8 x 0,14)C (12 x 0,14)C (18 x 0,14)C (24 x 0,14)C (36 x 0,14)C (48 x 0,14)C (4 x 0,25)C (8 x 0,25)C (18 x 0,25)C (24 x 0,25)C (48 x 0,25)C (12 G 0,5)C (18 G 0,5)C (4 G 0,75)C (12 G 0,75)C (24 G 0,75)C (5 G 1,0)C (24 G 1,0)C (3 G 1,5)C

External diameter approx. [mm] 6,0 8,0 9,0 10,0 11,5 14,0 16,0 7,0 8,0 13,0 14,0 18,0 18,0 22,0 10,0 19,0 25,0 12,0 26,0 11,0

Copper index [kg/km] 17 29 49 53 65 88 135 24 41 96 120 230 145 192 57 183 302 91 363 85

Weight [kg/km] 40 65 101 125 135 200 310 53 83 190 220 450 390 520 160 440 720 200 780 190

Order example: CF2.02.18 – in your desired length (0,5 m steps) CF2 chainflex series .02 Code nominal cross section .18 Number of cores ®

Please use www.chainflex.eu/en/CF2 for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.

(1) Delivery time upon inquiry. Deliverable alternative: CF10, CF10.UL, CF78.UL The chainflex® types marked with a (3) refer to cables that are based on a bundling of 4 cores each. Due to their excellent electrical properties (star-quad with especially minimum crosstalk), these cables can virtually be used in all cases in which otherwise twisted-pair cables are required. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

eplan download, configurator

www.igus.eu/en/CF2

950 types from stock no cutting costs ... 88

(for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

89


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:54 Seite 90

CF9 TPE 5xd

TPE Control cable CF9 ● ● ● ● ● ● ●

Class 7.4.4 (7 maximum load requirements

for maximum load requirements TPE outer jacket oil-resistant biooil-resistant PVC-free/halogen-free low-temperature-flexible hydrolysis-resistant and microbe-resistant

Conductor Core insulation Core stranding

T/R moved

Number of cores < 12: cores stranded in a layer with short pitch length. Number of cores ≥ 12: cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially lowtorsion structure. Cores < 0,75 mm2: Colour code in accordance with DIN 47100 Cores ≥ 0,75 mm2: cores black with white numerals, one core green-yellow CF9.02.03.INI: brown, blue, black CF9.03.04.INI: brown, blue, black, white CF9.03.05.INI: brown, blue, black, white, green-yellow CF9.03.16.07.03.INI: (0,75mm2): blue, green-yellow, brown (0,34mm2): violet, red, gray, red-blue, green, gray-pink, white-green, white-yellow, white-gray, black, yellow-brown, brown-green, white, yellow, pink, gray-brown Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Steel blue (similar to RAL 5011) -35 °C to +100 °C, minimum bending radius 5 x d

T/R fixed

-40 °C to +100 °C, minimum bending radius 3 x d

Core identification

Outer jacket

Nominal voltage

300/500 V (following DIN VDE 0245).

Testing voltage

2000 V (following DIN VDE 0281-2).

Oil

Halogen-free

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1, material/cable tested by IPA according to ISO standard 14644-1

Silicon-free

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture.

4 travel distance up to 400 m and more 4 oil-resistant)

CF9 TPE 5xd

Typical application area ● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m and more Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2 Travel distance Torsion

Freely suspended and gliding travel distances up to 400 m and more, Class 4 ± 90 °, with 1 m cable length

UV-resistant

High

Image exemplary.

chainflex® CF9 for outdoor crane systems. e-chain®: Series E4/00

eplan download, configurator

www.igus.eu/en/CF9

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Test data

Page 36 or www.igus.eu/en/test13

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

91


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:54 Seite 92

CF9 TPE 5xd

TPE Control cable CF9

Class 7.4.4 (7 maximum load requirements

4 travel distance up to 400 m and more 4 oil-resistant)

CF9 TPE 5xd

Image exemplary.

Delivery program Part No. CF9.01.03(1) CF9.02.02 CF9.02.03.INI CF9.02.06 CF9.02.07 CF9.02.08 CF9.02.12 CF9.02.20 CF9.03.04.INI CF9.03.05.INI CF9.03.06 CF9.03.08 CF9.03.16.07.03.INI CF9.05.02 CF9.05.03 CF9.05.04 CF9.05.05 CF9.05.07 CF9.05.12 CF9.05.18 CF9.05.25 CF9.05.36 CF9.07.05 CF9.07.07 CF9.07.12 CF9.07.20 CF9.07.25 CF9.10.03 CF9.10.04 CF9.10.05 CF9.10.12 CF9.10.18 CF9.10.25

Number of cores and conductor nominal cross section [mm2] 3 x 0,14 2 x 0,25 3 x 0,25 6 x 0,25 7 x 0,25 8 x 0,25 12 x 0,25 20 x 0,25 4 x 0,34 5 x 0,34 6 x 0,34 8 x 0,34 4 x 4 x 0,34+3 x 0,75 2 x 0,5 3 x 0,5 4 x 0,5 5 x 0,5 7 x 0,5 12 x 0,5 18 x 0,5 25 x 0,5 36 x 0,5 5 G 0,75 7 G 0,75 12 G 0,75 20 G 0,75 25 G 0,75 3 G 1,0 4 G 1,0 5 G 1,0 12 G 1,0 18 G 1,0 25 G 1,0

External diameter approx. [mm] 4,0 4,5 4,5 5,5 6,0 6,5 8,0 9,5 5,0 5,5 6,0 7,0 11,0 5,0 5,5 5,5 6,0 7,0 9,5 12,5 13,5 17,5 6,5 8,0 11,0 13,5 14,5 6,0 6,5 7,0 11,5 14,0 17,0

Copper index [kg/km] 5 5 8 15 17 20 29 53 13 17 20 26 74 10 15 20 24 34 58 86 120 173 36 50 86 144 180 29 38 48 115 173 241

Weight [kg/km] 15 18 20 35 42 46 70 104 31 37 43 55 159 31 32 36 46 78 105 165 201 368 58 76 142 231 320 49 56 70 181 267 329

Delivery program Part No.

New*

Number of cores and conductor nominal cross section [mm2] 2 x 1,5 4 G 1,5 5 G 1,5 7 G 1,5 12 G 1,5 18 G 1,5 25 G 1,5 36 G 1,5 4 G 2,5 5 G 2,5 7 G 2,5 12 G 2,5 16 G 2,5 18 G 2,5 25 G 2,5 4 G 4,0 4 G 6,0 5 G 6,0 4 G 10,0 4 G 16,0 4 G 35,0

CF9.15.02 CF9.15.04 CF9.15.05 CF9.15.07(17) CF9.15.12 CF9.15.18 CF9.15.25 CF9.15.36 CF9.25.04 CF9.25.05 CF9.25.07(17) CF9.25.12 CF9.25.16 CF9.25.18(7) CF9.25.25 CF9.40.04 CF9.60.04 CF9.60.05 CF9.100.04(6) CF9.160.04(6) CF9.350.04(6)

External diameter approx. [mm] 6,5 7,5 8,0 9,5 14,0 17,0 20,0 23,0 9,0 10,0 12,0 17,0 21,0 22,5 24,5 10,0 12,5 14,0 16,5 20,0 26,0

Copper index [kg/km] 29 58 72 101 173 260 360 519 96 120 168 288 384 432 600 154 230 288 384 614 1344

Weight [kg/km] 54 86 110 140 265 400 602 840 128 174 301 468 600 827 990 195 310 400 515 780 1700

(7) Nominal voltage 600/1000 V (6) Nominal voltage 450/750 V (17) Using the cables with "7 G 1,5 mm2" and "7 G 2,5 mm2" it is essential: bending radius 17 x d with travel distance ≥ 5 m. When the travel distance is not less than 5 m, a bending radius not less than 17 x d has to be used. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF9.25.04 – in your desired length (0,5 m steps) CF9 chainflex series .25 Code nominal cross section .04 Number of cores ®

Please use www.chainflex.eu/en/CF9 for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.

(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalogue.

eplan download, configurator

www.igus.eu/en/CF9

950 types from stock no cutting costs ... 92

(for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

93


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:54 Seite 94

CF10 TPE 5xd

TPE Control cable CF10 ● ● ● ● ● ● ● ●

Class 7.4.4 (7 maximum load requirements

for maximum load requirements TPE outer jacket shielded oil-resistant biooil-resistant PVC-free/halogen-free low-temperature-flexible hydrolysis-resistant and microbe-resistant Conductor

Mechanically high-quality TPE mixture.

Core stranding

Number of cores < 12: cores stranded in a layer with short pitch length. Number of cores ≥ 12: cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially lowtorsion structure. Cores < 0,75 mm2: Colour code in accordance with DIN 47100 Cores ≥ 0,75 mm2: cores black with white numerals, one core green-yellow CF10.03.05.INI: brown, blue, black, white, green-yellow TPE mixture adapted to suit the requirements in energy chains®.

Inner jacket Overall shield

T/R moved

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Steel blue (similar to RAL 5011) -35 °C to +100 °C, minimum bending radius 5 x d

T/R fixed

-40 °C to +100 °C, minimum bending radius 3 x d

Outer jacket

Halogen-free

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

Silicon-free

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228).

Core insulation

Core identification

Oil

4 travel distance up to 400 m and more 4 oil-resistant)

CF10 TPE 5xd

Typical application area ● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m and more Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2

Image exemplary.

Travel distance UV-resistant

Freely suspended and gliding travel distances up to 400 m and more, Class 4 High

Nominal voltage

300/500 V (following DIN VDE 0245).

Testing voltage

2000 V (following DIN VDE 0281-2).

eplan download, configurator

www.igus.eu/en/CF10

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Control cable chainflex® CF10 in storage and retrieval units for high-bay warehouses. e-chain®: System E2 medium

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

95


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:54 Seite 96

CF10 TPE 5xd

TPE Control cable CF10

Class 7.4.4 (7 maximum load requirements

4 travel distance up to 400 m and more 4 oil-resistant)

CF10 TPE 5xd

Image exemplary.

Delivery program Part No. CF10.01.12 CF10.01.18 CF10.02.04 CF10.02.08 CF10.02.12 CF10.02.24 CF10.03.05.INI CF10.05.04 CF10.05.05 CF10.05.07 CF10.05.12 CF10.05.18 CF10.05.25 CF10.07.04 CF10.07.05 CF10.07.07 CF10.07.12 CF10.07.20 CF10.07.24 CF10.10.02 CF10.10.03 CF10.10.04 CF10.10.05 CF10.10.07 CF10.10.12 CF10.10.18 CF10.10.24 CF10.15.04 CF10.15.05 CF10.15.07 CF10.15.12 CF10.15.18

Number of cores and conductor nominal cross section [mm2] (12 x 0,14)C (18 x 0,14)C (4 x 0,25)C (8 x 0,25)C (12 x 0,25)C (24 x 0,25)C (5 x 0,34)C (4 x 0,5)C (5 x 0,5)C (7 x 0,5)C (12 x 0,5)C (18 x 0,5)C (25 x 0,5)C (4 G 0,75)C (5 G 0,75)C (7 G 0,75)C (12 G 0,75)C (20 G 0,75)C (24 G 0,75)C (2 x 1,0)C (3 G 1,0)C (4 G 1,0)C (5 G 1,0)C (7 G 1,0)C (12 G 1,0)C (18 G 1,0)C (24 G 1,0)C (4 G 1,5)C (5 G 1,5)C (7 G 1,5)C (12 G 1,5)C (18 G 1,5)C

External diameter approx. [mm] 7,5 10,0 6,5 7,5 9,5 13,0 7,0 7,0 7,5 8,5 11,5 13,5 14,5 7,5 7,5 9,0 12,5 15,0 16,5 7,0 7,5 8,0 8,5 10,0 13,5 16,5 18,0 9,0 9,5 11,5 15,5 20,0

Copper index [kg/km] 36 67 25 40 64 109 32 38 41 54 102 143 167 47 57 85 138 205 239 38 47 59 71 105 169 240 305 96 108 155 235 361

Weight [kg/km] 80 110 52 75 118 212 62 68 74 96 192 270 280 86 95 137 244 346 419 70 84 100 101 166 293 407 506 144 163 225 387 585

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] (4 G 2,5)C (7 G 2,5)C (12 G 2,5)C (4 G 4,0)C (5 G 4,0)C

CF10.25.04 CF10.25.07 CF10.25.12 CF10.40.04 CF10.40.05

External diameter approx. [mm] 11,0 13,5 19,0 11,5 13,5

Copper index [kg/km] 126 221 373 200 246

Weight [kg/km] 180 331 624 290 353

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. x = without earth core G = with green-yellow earth core

Order example: CF10.10.12 – in your desired length (0,5 m steps) CF10 chainflex series .10 Code nominal cross section .12 Number of cores ®

Please use www.chainflex.eu/en/CF10 for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

eplan download, configurator

www.igus.eu/en/CF10

950 types from stock no cutting costs ... 96

(for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

97


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:54 Seite 98

CF9.UL TPE 5xd

TPE Control cable CF9.UL ● ● ● ● ● ● ● ●

Class 6.4.4 (6 maximum load requirements

for maximum load requirements TPE outer jacket oil-resistant biooil-resistant flame-retardant PVC-free low-temperature-flexible hydrolysis-resistant and microbe-resistant Conductor Core insulation Core stranding

T/R moved T/R fixed

-40 °C to +100 °C, minimum bending radius 3 x d

Outer jacket

Flame-retardant Silicon-free

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

NFPA

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). < 0,5 mm2: Style 10479 and 21529, 300 V, 90 °C ≥ 0,5 mm2: Style 10258 and 21530, 600 V, 90 °C Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, tested by IPA according to standard 14644-1

UL/CSA

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture. Number of cores < 12: cores stranded in a layer with short pitch length. Number of cores ≥ 12: cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially lowtorsion structure. Cores < 0,75 mm2: Colour code in accordance with DIN 47100 Cores ≥ 0,75 mm2: cores black with white numerals, one core green-yellow CF9.UL.02.03.INI: brown, blue, black CF9.UL.03.04.INI: brown, blue, black, white CF9.UL.03.05.INI: brown, blue, black, white, green-yellow Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Steel blue (similar to RAL 5011) -35 °C to +100 °C, minimum bending radius 5 x d

Core identification

Oil

4 travel distance up to 400 m and more 4 oil-resistant)

CF9.UL TPE 5xd

Typical application area ● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m and more Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2

Image exemplary.

Travel distance Torsion

Freely suspended and gliding travel distances up to 400 m and more, Class 4 ± 90 °, with 1 m cable length

UV-resistant

High

Nominal voltage

300/500 V (following DIN VDE 0245).

Testing voltage

2000 V (following DIN VDE 0281-2).

eplan download, configurator

www.igus.eu/en/CF9UL

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

igus® chainflex® cables in a rafting channel application.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

99


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:54 Seite 100

CF9.UL TPE 5xd

TPE Control cable CF9.UL

Class 6.4.4 (6 maximum load requirements

4 travel distance up to 400 m and more 4 oil-resistant)

CF9.UL TPE 5xd

Image exemplary.

Delivery program Part No. CF9.UL.02.02 CF9.UL.02.03.INI CF9.UL.02.04 CF9.UL.02.06 CF9.UL.02.07(1) CF9.UL.02.08 CF9.UL.02.12 CF9.UL.03.04.INI CF9.UL.03.05.INI(1) CF9.UL.03.06 CF9.UL.03.08(1) CF9.UL.05.02 CF9.UL.05.03(1) CF9.UL.05.04 CF9.UL.05.05(1) CF9.UL.05.07 CF9.UL.05.12 CF9.UL.05.18 CF9.UL.05.25(1) CF9.UL.05.36(1) CF9.UL.07.05 CF9.UL.07.07 CF9.UL.07.12 CF9.UL.07.20(1) CF9.UL.07.25 CF9.UL.10.03 CF9.UL.10.04 CF9.UL.10.05(1) CF9.UL.10.12 CF9.UL.10.18 CF9.UL.10.25

Number of cores and conductor nominal cross section [mm2] 2 x 0,25 3 x 0,25 4 x 0,25 6 x 0,25 7 x 0,25 8 x 0,25 12 x 0,25 4 x 0,34 5 x 0,34 6 x 0,34 8 x 0,34 2 x 0,5 3 x 0,5 4 x 0,5 5 x 0,5 7 x 0,5 12 x 0,5 18 x 0,5 25 x 0,5 36 x 0,5 5 G 0,75 7 G 0,75 12 G 0,75 20 G 0,75 25 G 0,75 3 G 1,0 4 G 1,0 5 G 1,0 12 G 1,0 18 G 1,0 25 G 1,0

External diameter approx. [mm] 5,0 5,5 5,5 6,0 6,5 7,0 8,5 6,0 6,0 6,5 7,5 6,0 6,5 7,0 7,0 8,5 11,0 13,5 14,5 18,5 8,0 9,5 12,5 15,5 16,5 7,5 8,0 8,5 13,5 16,5 18,5

Copper index [kg/km] 5 8 10 15 17 20 29 13 16 20 26 10 15 20 24 34 58 87 120 173 36 51 87 144 180 29 39 48 116 173 240

Weight [kg/km]

Delivery program Part No.

28 32 38 50 57 63 95 43 51 58 76 44 52 62 72 97 196 242 305 456 94 128 240 342 412 78 98 112 287 394 520

CF9.UL.15.04 CF9.UL.15.05 CF9.UL.15.07(17) CF9.UL.15.12 CF9.UL.15.18 CF9.UL.15.25 CF9.UL.25.04 CF9.UL.25.05 CF9.UL.25.07(1/17) CF9.UL.25.12 CF9.UL.25.16(1) CF9.UL.25.18 CF9.UL.25.25 CF9.UL.40.04 CF9.UL.60.04

Number of cores and conductor nominal cross section [mm2] 4 G 1,5 5 G 1,5 7 G 1,5 12 G 1,5 18 G 1,5 25 G 1,5 4 G 2,5 5 G 2,5 7 G 2,5 12 G 2,5 16 G 2,5 18 G 2,5 25 G 2,5 4 G 4,0 4 G 6,0

External diameter approx. [mm] 9,0 9,5 11,0 15,5 19,0 22,0 10,5 11,0 13,5 19,0 21,5 23,5 26,5 12,0 13,5

Copper index [kg/km] 58 72 101 173 260 360 96 120 168 288 384 432 600 154 231

Weight [kg/km] 127 152 198 385 535 685 189 220 288 613 805 852 1163 278 382

(1) Delivery time upon inquiry. (17) Using the cables with "7 G 1,5 mm2" and "7 G 2,5 mm2" it is essential: bending radius 17 x d with travel distance ≥ 5 m. When the travel distance is not less than 5 m, a bending radius not less than 17 x d has to be used. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF9.UL.02.12 – in your desired length (0,5 m steps) CF9.UL chainflex series .02 Code nominal cross section .12 Number of cores ®

Please use www.chainflex.eu/en/CF9UL for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.

(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

eplan download, configurator

www.igus.eu/en/CF9UL

950 types from stock no cutting costs ... 100

(for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

101


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:54 Seite 102

CF10.UL TPE 5xd

TPE Control cable CF10.UL ● ● ● ● ● ● ● ●

Class 6.4.4 (6 maximum load requirements

for maximum load requirements TPE outer jacket shielded oil-resistant, biooil-resistant flame-retardant PVC-free low-temperature-flexible hydrolysis-resistant and microbe-resistant Conductor Core insulation Core stranding

Core identification

Inner jacket Overall shield

Number of cores < 12: cores stranded in a layer with short pitch length. Number of cores ≥ 12: cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially lowtorsion structure. Cores < 0,75 mm2: Colour code in accordance with DIN 47100 Cores ≥ 0,75 mm2: cores black with white numerals, one core green-yellow TPE mixture adapted to suit the requirements in energy chains®.

T/R moved T/R fixed

-40 °C to +100 °C, minimum bending radius 3 x d

NFPA

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). < 0,5 mm2: Style 10479 and 21529, 300 V, 90 °C ≥ 0,5 mm2: Style 10258 and 21530, 600 V, 90 °C Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, tested by IPA according to standard 14644-1

UL/CSA

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture.

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Steel blue (similar to RAL 5011) -35 °C to +100 °C, minimum bending radius 5 x d

Outer jacket

Silicon-free

Typical application area ● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m and more Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

Braiding in bundles

v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2 Travel distance UV-resistant

Center element for high tensile stresses

Gusset-filling extruded inner jacket

Freely suspended and gliding travel distances up to 400 m and more, Class 4 High

Nominal voltage

300/500 V (following DIN VDE 0245).

Testing voltage

2000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Flame-retardant

4 travel distance up to 400 m and more 4 oil-resistant)

CF10.UL TPE 5xd

Total shield with optimized braiding angle

Image exemplary.

Pressure extruded outer jacket

eplan download, configurator

www.igus.eu/en/CF10UL

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

The special cable structure of chainflex® CF10.UL guarantees quality – also in the igus® harnessing.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

103


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:54 Seite 104

CF10.UL TPE 5xd

TPE Control cable CF10.UL

Class 6.4.4 (6 maximum load requirements

4 travel distance up to 400 m and more 4 oil-resistant)

CF10.UL TPE 5xd

Image exemplary.

Delivery program Part No. CF10.UL.02.04 CF10.UL.02.08 CF10.UL.02.12 CF10.UL.02.24 CF10.UL.05.04 CF10.UL.05.05(1) CF10.UL.05.12 CF10.UL.05.18(1) CF10.UL.05.25 CF10.UL.07.03 CF10.UL.07.04 CF10.UL.07.05 CF10.UL.07.07 CF10.UL.07.12 CF10.UL.07.20(1) CF10.UL.07.24(1) CF10.UL.10.02(1) CF10.UL.10.03(1) CF10.UL.10.04 CF10.UL.10.05(1) CF10.UL.10.07 CF10.UL.10.12 CF10.UL.10.18(1) CF10.UL.10.24(1) CF10.UL.15.04 CF10.UL.15.05 CF10.UL.15.07 CF10.UL.15.12 CF10.UL.15.18 CF10.UL.25.04 CF10.UL.25.07 CF10.UL.25.12 CF10.UL.40.04

Number of cores and conductor nominal cross section [mm2] (4 x 0,25)C (8 x 0,25)C (12 x 0,25)C (24 x 0,25)C (4 x 0,5)C (5 x 0,5)C (12 x 0,5)C (18 x 0,5)C (25 x 0,5)C (3 G 0,75)C (4 G 0,75)C (5 G 0,75)C (7 G 0,75)C (12 G 0,75)C (20 G 0,75)C (24 G 0,75)C (2 x 1,0)C (3 G 1,0)C (4 G 1,0)C (5 G 1,0)C (7 G 1,0)C (12 G 1,0)C (18 G 1,0)C (24 G 1,0)C (4 G 1,5)C (5 G 1,5)C (7 G 1,5)C (12 G 1,5)C (18 G 1,5)C (4 G 2,5)C (7 G 2,5)C (12 G 2,5)C (4 G 4,0)C

External diameter approx. [mm] 7,0 8,5 10,0 13,0 8,5 8,5 13,0 15,0 16,0 8,5 9,0 9,5 11,0 14,5 17,0 19,0 8,5 9,0 9,5 10,5 12,0 14,5 19,0 21,5 10,5 11,0 13,0 17,5 21,5 12,0 15,0 21,5 13,5

Copper index [kg/km] 25 37 63 109 37 43 106 146 185 40 49 68 90 143 213 276 38 48 71 83 111 171 274 346 192 215 149 243 375 140 227 404 206

Weight [kg/km] 71 101 153 242 101 111 258 332 411 104 123 150 194 336 456 578 104 120 155 174 230 370 545 709 94 112 279 508 724 268 404 804 369

Order example: CF10.UL.10.02 – in your desired length (0,5 m steps) CF10.UL chainflex series .10 Code nominal cross section .02 Number of cores ®

Please use www.chainflex.eu/en/CF10UL for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.

(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

eplan download, configurator

www.igus.eu/en/CF10UL

950 types from stock no cutting costs ... 104

(for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

105


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:54 Seite 106

CF98 TPE 4xd

TPE Control cable CF98

Class 7.4.4 (7 maximum load requirements

● for maximum load requirements and especially small radii up to 4xd ● TPE outer jacket ● oil-resistant, biooil-resistant ● PVC-free/halogen-free ● low-temperature-flexible ● hydrolysis-resistant and microbe-resistant

4 travel distance up to 400 m and more 4 oil-resistant)

CF98 TPE 4xd

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

Typical application area Conductor

Conductor consisting of a highly flexible special alloy.

Core insulation

Mechanically high-quality TPE mixture.

Core stranding

Cores stranded in one layer with especially short pitch length.

Core identification

T/R moved

Colour code in accordance with DIN 47100. CF98.02.03.INI: brown, blue, black CF98.03.04.INI: brown, blue, black, white Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Steel blue (similar to RAL 5011) -35 °C to +90 °C, minimum bending radius 4 x d

T/R fixed

-40 °C to +90 °C, minimum bending radius 3 x d

Outer jacket

v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2 Travel distance Torsion

Short, very fast applications with small radii and tight design space, Class 4 ± 90 °, with 1 m cable length

UV-resistant

High

Nominal voltage

300/300 V

Testing voltage

1500 V

● ● ● ● ●

for maximum load requirements at 4 x d almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for short, very fast applications with small radii and tight design space automatic insertion machines, automatic doors, clean room, very quick handling

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] 2 x 0,14 3 x 0,14 4 x 0,14 7 x 0,14 8 x 0,14 3 x 0,25 4 x 0,25 7 x 0,25 8 x 0,25 3 x 0,34 4 x 0,34 7 x 0,34 8 x 0,34 4 x 0,5

CF98.01.02 CF98.01.03(1) CF98.01.04 CF98.01.07(1) CF98.01.08 CF98.02.03.INI CF98.02.04 CF98.02.07 CF98.02.08 CF98.03.03(1) CF98.03.04.INI CF98.03.07 CF98.03.08(1) CF98.05.04

External diameter approx. [mm] 4,0 4,5 5,0 6,0 6,5 5,0 5,5 6,5 7,0 5,0 5,5 7,0 7,5 6,0

Copper index [kg/km] 4 6 9 14 16 12 16 26 30 14 19 32 38 31

Weight [kg/km] 11 14 16 21 24 25 30 53 60 28 35 55 63 40

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF98.02.04 – in your desired length (0,5 m steps) CF98 chainflex series .02 Code nominal cross section .04 Number of cores ®

Oil

Silicon-free

Image exemplary.

Halogen-free

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

eplan download, configurator

www.igus.eu/en/CF98

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Please use www.chainflex.eu/en/CF98 for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.

Test data

Page 36 or www.igus.eu/en/test10

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

107


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:54 Seite 108

CF99 TPE 4xd

TPE Control cable CF99

Class 7.4.4 (7 maximum load requirements

● for maximum load requirements and especially small radii up to 4xd ● TPE outer jacket ● shielded ● oil-resistant, biooil-resistant ● PVC-free/halogen-free ● low-temperature-flexible ● hydrolysis-resistant and microbe-resistant Conductor

Silicon-free

4 travel distance up to 400 m and more 4 oil-resistant)

CF99 TPE 4xd

CE

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

Conductor consisting of a highly flexible special alloy.

Typical application area Core insulation

Mechanically high-quality TPE mixture.

Core stranding

Cores stranded in one layer with especially short pitch length.

Core identification

Colour code in accordance with DIN 47100. CF99.02.03.INI: brown, blue, black CF99.03.04.INI: brown, blue, black, white TPE mixture adapted to suit the requirements in energy chains®.

Inner jacket Overall shield

T/R moved

Highly flexible alloyed special shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Steel blue (similar to RAL 5011) -35 °C to +90 °C, minimum bending radius 4 x d

T/R fixed

-40 °C to +90 °C, minimum bending radius 3 x d

Outer jacket

v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2 Travel distance UV-resistant

Short, very fast applications with small radii and tight design space, Class 4 High

Nominal voltage

300/300 V

● ● ● ● ●

for maximum load requirements at 4xd almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for short, very fast applications with small radii and tight design space automatic insertion machines, automatic doors, clean room, very quick handling

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] (2 x 0,14)C (3 x 0,14)C (4 x 0,14)C (7 x 0,14)C (8 x 0,14)C (3 x 0,25)C (4 x 0,25)C (7 x 0,25)C (8 x 0,25)C (3 x 0,34)C (4 x 0,34)C (8 x 0,34)C

CF99.01.02 CF99.01.03(1) CF99.01.04 CF99.01.07(1) CF99.01.08 CF99.02.03.INI(1) CF99.02.04 CF99.02.07 CF99.02.08(1) CF99.03.03(1) CF99.03.04.INI(1) CF99.03.08

External diameter approx. [mm] 5,5 6,0 6,0 7,5 8,0 6,5 6,5 8,0 8,5 6,5 7,0 9,0

Copper index [kg/km] 14 17 21 32 36 25 30 48 54 27 35 64

Weight [kg/km] 33,0 37,0 43,0 62,0 69,0 48,0 56,0 85,0 93,0 51,0 62,0 105,0

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF99.01.02 – in your desired length (0,5 m steps) CF99 chainflex series .01 Code nominal cross section .02 Number of cores ®

Testing voltage

1500 V

Please use www.chainflex.eu/en/CF99 for your online order.

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Following EN 50267-2-1.

Delivery time means time until shipping of goods.

Image exemplary.

Halogen-free

eplan download, configurator

Delivery time 24h or today.

www.igus.eu/en/CF99

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

109


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 110

v max. [m/s] gliding

a max. [m/s2]

Page

-5/ +70

3

2

20

112

CF240.PUR

PUR

10-12

-20/ +80

3

2

20

114 *

Oil-resistant

10-12

Temperature moved from/to [°C]

Shield

PVC

Jacket

CF240

chainflex® cable

v max. [m/s] unsupported

Approvals and standards

Minimum bending radius, moved [factor x d]

chainflex type

Torsion resistant

®

Coaxial cables

Data cables

Data cables – Stranded in layers

Data cables – Twisted pair CF211

PVC

7,5

-5/ +70

5

3

50

116

CF113

PUR

10

-20/ +80

10

5

80

118

CF11

TPE

6,8

-35/ +100

10

6

100

120

Data cables – Twisted pair/Pair shield CF112

PUR

10

-20/ +80

10

5

80

122

CF12

TPE

10

-35/ +100

10

6

100

124

-20/ +80

2

1

20

-35/ +100

10

5

100

Data cables – Thermo (Chapter "Special cables" CF THERMO

PUR

✔ 12,5-15

256)

Data cables – Coax CF KOAX 1

TPE

10

128

111


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 112

CF240 PVC 10-12 x d

PVC Data cable CF240 ● ● ● ● ●

Class 4.2.2 (4 medium load requirements

for medium load requirements PVC outer jacket shielded oil-resistant flame-retardant

Conductor Core insulation Core stranding Core identification

Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality PP mixture. The individual cores are stranded in layers with short pitch lengths. Colour code in accordance with DIN 47100.

Intermediate jacket Foil taping over the external layer. Overall shield Outer jacket

T/R moved

T/R fixed

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in energy chains® (following DIN VDE 0281 Part 13). Colour: Silver gray (similar to RAL 7001) -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2. +5 °C to +70 °C for use in energy chains® with > 50.000 cycles. Minimum bending radius 10 x d with < 10 m travel distance, minimum bending radius 12 x d with ≥ 10 m travel distance. -20 °C to +70 °C, minimum bending radius 5 x d

Image exemplary.

v max. 3 m/s, 2 m/s unsupported/gliding a max. 20 m/s2 Travel distance

Freely suspended and gliding travel distances up to 50 m, Class 2

Nominal voltage

300/300 V (following DIN VDE 0245).

Testing voltage

1500 V

Oil

Oil-resistant (following DIN EN 50363-4-1), Class 2.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).

eplan download, configurator

www.igus.eu/en/CF240

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

2 travel distance up to 50 m 2 oil-resistant)

CF240 PVC 10-12 x d

UL/CSA

Style 10493 and 2464, 300 V, 80 °C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1.

Typical application area ● ● ● ● ●

for medium load requirements light oil influence preferably indoor applications, but also outdoor ones at temperatures > 5 °C especially for freely suspended and gliding travel distances up to 50 m Storage and retrieval units for high-bay warehouses, machining units/packaging machines, handling, indoor cranes

Delivery program Part No. CF240.01.03 CF240.01.04 CF240.01.05 CF240.01.07 CF240.01.14 CF240.01.18 CF240.01.24 CF240.02.03 CF240.02.04 CF240.02.05 CF240.02.07 CF240.02.08 CF240.02.14 CF240.02.18 CF240.02.24 CF240.03.03 CF240.03.04 CF240.03.05 CF240.03.07 CF240.03.10 CF240.03.14 CF240.03.18 CF240.03.24

Number of cores and conductor nominal cross section [mm2] (3 x 0,14)C (4 x 0,14)C (5 x 0,14)C (7 x 0,14)C (14 x 0,14)C (18 x 0,14)C (24 x 0,14)C (3 x 0,25)C (4 x 0,25)C (5 x 0,25)C (7 x 0,25)C (8 x 0,25)C (14 x 0,25)C (18 x 0,25)C (24 x 0,25)C (3 x 0,34)C (4 x 0,34)C (5 x 0,34)C (7 x 0,34)C (10 x 0,34)C (14 x 0,34)C (18 x 0,34)C (24 x 0,34)C

External diameter approx. [mm] 4,5 5,0 5,5 6,0 7,0 8,0 9,5 5,5 5,5 6,0 7,0 7,5 8,0 9,0 11,0 5,5 6,0 6,5 7,0 8,5 8,5 10,0 12,0

Copper index [kg/km] 16 18 20 25 42 48 60 21 24 27 35 40 57 71 92 24 28 32 43 55 71 87 115

Weight [kg/km] 35 38 42 51 76 90 113 40 48 52 66 74 100 122 174 45 51 58 75 110 116 140 203

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

113


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 114

CF240.PUR PUR 10-12 x d

PUR Data cable CF240.PUR ● ● ● ● ● ● ● ●

Class 5.2.3 (5 high load requirements

for high load requirements PUR outer jacket shielded oil-resistant and coolant-resistant notch-resistant PVC-free/halogen-free flame-retardant hydrolysis-resistant and microbe-resistant Conductor Core insulation Core stranding Core identification

Silicon-free

Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality PP mixture. The individual cores are stranded in layers with short pitch lengths. Colour code in accordance with DIN 47100

2 travel distance up to 50 m 3 oil-resistant)

CF240.PUR PUR 10-12 x d

Halogen-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

UL/CSA

Style 10493 and 20233, 300 V, 80°C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1

Intermediate jacket Foil taping over the external layer

Typical application area Overall shield Outer jacket

T/R moved T/R fixed

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Silver gray (similar to RAL 7001) -20 °C to +80 °C, minimum bending radius 10 x d with < 10 m travel distance, minimum bending radius 12 x d with ≥ 10 m travel distance -40 °C to +80 °C, minimum bending radius 5 x d

v max. 3 m/s, 2 m/s unsupported/gliding a max. 20 m/s2

Image exemplary.

Travel distance UV-resistant

Freely suspended and gliding travel distances up to 50 m, Class 2. Medium

Nominal voltage

300/300 V (following DIN VDE 0245)

Testing voltage

1500 V

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

Offshore

MUD-resistant following NEK 606 – status 2009.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

eplan download, configurator

www.igus.eu/en/CF240PUR

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

● ● ● ● ●

for high load requirements almost unlimited resistance to oil indoor and outdoor applications with average sun radiation especially for freely suspended and gliding travel distances up to 50 m Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling, refrigerating sector

Delivery program Part No. CF240.PUR.01.03(1) CF240.PUR.01.04 CF240.PUR.01.05(1) CF240.PUR.01.07(1) CF240.PUR.01.14 CF240.PUR.01.18(1) CF240.PUR.02.03 CF240.PUR.02.04 CF240.PUR.02.05 CF240.PUR.02.07 CF240.PUR.02.08 CF240.PUR.02.14 CF240.PUR.02.18 CF240.PUR.03.03(1) CF240.PUR.03.04 CF240.PUR.03.05(1) CF240.PUR.03.07 CF240.PUR.03.14(1) CF240.PUR.03.18(1)

Number of cores and conductor nominal cross section [mm2] (3 x 0,14)C (4 x 0,14)C (5 x 0,14)C (7 x 0,14)C (14 x 0,14)C (18 x 0,14)C (3 x 0,25)C (4 x 0,25)C (5 x 0,25)C (7 x 0,25)C (8 x 0,25)C (14 x 0,25)C (18 x 0,25)C (3 x 0,34)C (4 x 0,34)C (5 x 0,34)C (7 x 0,34)C (14 x 0,34)C (18 x 0,34)C

External diameter approx. [mm] 5,5 6,0 6,5 7,0 8,0 8,5 6,0 6,0 6,5 7,0 7,5 8,0 9,0 6,0 6,5 7,0 8,0 9,5 10,0

Copper index [kg/km] 16 18 20 25 42 48 21 24 27 35 40 57 71 24 28 32 43 71 88

Weight [kg/km] 35 38 43 52 77 92 40 44 49 63 69 100 119 46 52 58 82 123 152

(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

115


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 116

CF211 PVC 7,5 x d

PVC Data cable CF211 ● ● ● ● ● ●

Class 5.3.2 (5 high load requirements

for high load requirements PVC outer jacket shielded twisted-pair oil-resistant flame-retardant

Conductor Core insulation Core stranding Core identification

Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality PP mixture. 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Colour code in accordance with DIN 47100.

Intermediate jacket Foil taping over the external layer. Overall shield Outer jacket

T/R moved

T/R fixed

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in energy chains® (following DIN VDE 0281 Part 13). Colour: Silver gray (similar to RAL 7001) -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2. +5 °C to +70 °C for use in energy chains® with > 50.000 cycles. Minimum bending radius 7,5 x d. Following an extensive series of tests, the bending radius of CF211 has been reduced from 10 x d to 7,5 x d. -20 °C to +70 °C, minimum bending radius 5 x d

v max. 5 m/s, 3 m/s unsupported/gliding a max. 50 m/s2 Travel distance Nominal voltage

Freely suspended and gliding travel distances up to 100 m, Class 3 300/300 V (following DIN VDE 0245).

Testing voltage

1500 V

Oil

Oil-resistant (following DIN EN 50363-4-1), Class 2.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Style 10493 and 2464, 300 V, 80 °C

Image exemplary.

UL/CSA

eplan download, configurator

www.igus.eu/en/CF211

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

3 travel distance up to 100 m 2 oil-resistant)

CF211 PVC 7,5 x d

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1.

Typical application area ● ● ● ● ●

for high load requirements light oil influence preferably indoor applications, but also outdoor ones at temperatures > 5 °C especially for freely suspended and gliding travel distances up to 100 m Storage and retrieval units for high-bay warehouses, machining units/packaging machines, handling, indoor cranes

Delivery program Part No. CF211.02.01.02 CF211.02.02.02(2) CF211.02.03.02 CF211.02.04.02 CF211.02.05.02 CF211.02.06.02 CF211.02.08.02 CF211.02.10.02 CF211.02.14.02 CF211.03.03.02 CF211.03.08.02 CF211.03.10.02(1) CF211.05.01.02 CF211.05.02.02(2) CF211.05.03.02 CF211.05.04.02 CF211.05.05.02 CF211.05.06.02 CF211.05.08.02 CF211.05.10.02 CF211.05.14.02

Number of cores and conductor nominal cross section [mm2] (1 x (2 x 0,25))C (2 x (2 x 0,25))C (3 x (2 x 0,25))C (4 x (2 x 0,25))C (5 x (2 x 0,25))C (6 x (2 x 0,25))C (8 x (2 x 0,25))C (10 x (2 x 0,25))C (14 x (2 x 0,25))C (3 x (2 x 0,34))C (8 x (2 x 0,34))C (10 x (2 x 0,34))C (1 x (2 x 0,5))C (2 x (2 x 0,5))C (3 x (2 x 0,5))C (4 x (2 x 0,5))C (5 x (2 x 0,5))C (6 x (2 x 0,5))C (8 x (2 x 0,5))C (10 x (2 x 0,5))C (14 x (2 x 0,5))C

External diameter approx. [mm] 5,0 5,5 7,0 8,0 8,5 9,5 11,5 13,0 13,5 8,0 12,0 12,0 5,5 8,5 9,0 9,5 11,0 12,5 14,5 16,0 17,0

Copper index [kg/km] 16 28 37 44 51 58 75 93 109 37 98 118 23 44 57 68 80 99 124 175 187

Weight [kg/km] 35 60 73 85 97 110 160 195 205 79 202 254 50 80 100 120 145 185 230 320 335

(1) Delivery time upon inquiry. The chainflex® types marked with (2) are cables designed as a star-quad. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Delivery program Measuring system cables Page 164, CF211 (PVC) Page 170, CF111.D (TPE) Page 180, CF11.D (TPE)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

117


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 118

CF113 PUR 10 x d

PUR Data cable CF113 ● ● ● ● ● ● ● ●

Class 6.3.3 (6 maximum load requirements

for maximum load requirements PUR outer jacket shielded, twisted-pair oil-resistant and coolant-resistant notch-resistant PVC-free/halogen-free flame-retardant hydrolysis-resistant and microbe-resistant Conductor Core insulation Core stranding Core identification

Silicon-free

Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality TPE mixture.

3 travel distance up to 100 m 3 oil-resistant)

Halogen-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

UL/CSA

Style 10493 and 20233, 300 V, 80°C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

CF113 PUR 10 x d

2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Colour code in accordance with DIN 47100

Typical application area Intermediate jacket PUR mixture adapted to suit the requirements in energy chains . ®

Overall shield Outer jacket

T/R moved T/R fixed

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Anthracite gray (similar to RAL 7016) -20 °C to +80 °C, minimum bending radius 10 x d -40 °C to +80 °C, minimum bending radius 5 x d

v max. 10 m/s, 5 m/s unsupported/gliding a max. 80 m/s2 Travel distance UV-resistant

Freely suspended and gliding travel distances up to 100 m, Class 3 High

Nominal voltage

300/300 V (following DIN VDE 0245).

Testing voltage

1500 V

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

Offshore

MUD-resistant following NEK 606 – status 2009.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

.

● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil indoor and outdoor applications with average sun radiation especially for freely suspended and gliding travel distances up to 100 m Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling, refrigerating sector

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] (2 x (2 x 0,25))C (3 x (2 x 0,25))C (4 x (2 x 0,25))C (5 x (2 x 0,25))C (6 x (2 x 0,25))C (8 x (2 x 0,25))C (2 x (2 x 0,5))C (3 x (2 x 0,5))C (4 x (2 x 0,5))C (5 x (2 x 0,5))C (6 x (2 x 0,5))C

CF113.02.02.02(2) CF113.02.03.02 CF113.02.04.02 CF113.02.05.02 CF113.02.06.02 CF113.02.08.02 New* CF113.05.02.02(2) CF113.05.03.02(1) CF113.05.04.02 CF113.05.05.02(1) CF113.05.06.02

External diameter approx. [mm] 8,0 8,5 9,0 9,5 10,0 11,5 10,0 10,5 11,0 11,5 12,5

Copper index [kg/km] 31 40 45 56 62 81 50 62 70 84 95

Weight [kg/km] 86 96 107 125 137 176 127 142 162 185 207

(1) Delivery time upon inquiry The chainflex® types marked with (2) are cables designed as a star-quad. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalog.

Order example: CF113.02.06.02 – in your desired length (0,5 m steps) CF113 chainflex series .02 Code nominal cross section .06 Number of pairs .02 Identification pairs ®

Please use www.chainflex.eu/en/CF113 for your online order.

Image exemplary.

Delivery time 24h or today. eplan download, configurator

www.igus.eu/en/CF113

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Delivery time means time until shipping of goods.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

119


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 120

CF11 TPE 6,8 x d

TPE Data cable CF11 ● ● ● ● ● ● ●

Class 6.4.4 (6 maximum load requirements

for maximum load requirements TPE outer jacket shielded twisted-pair oil-resistant, biooil-resistant PVC-free/halogen-free hydrolysis-resistant and microbe-resistant

Conductor Core insulation Core stranding Core identification Inner jacket Overall shield Outer jacket

T/R moved

T/R fixed

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture. 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Cores < 1,0 mm2: Colour code in accordance with DIN 47100 Cores ≥ 1,0 mm2: Cores black with white numerals TPE mixture adapted to suit the requirements in energy chains®. Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Steel blue (similar to RAL 5011) -35 °C to +100 °C, minimum bending radius 6,8 x d. Following an extensive series of tests, the bending radius of CF11 has been reduced from 10 x d to 6,8 x d. -40 °C to +100 °C, minimum bending radius 5 x d

v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2 Travel distance UV-resistant

Freely suspended and gliding travel distances up to 400 m and more, Class 4 High

Nominal voltage

300/300 V (following DIN VDE 0245).

Testing voltage

1500 V

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).

Image exemplary.

Silicon-free

eplan download, configurator

www.igus.eu/en/CF11

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

4 travel distance up to 400 m and more 4 oil-resistant)

CF11 TPE 6,8 x d

Halogen-free

Following EN 50267-2-1.

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

Typical application area ● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m and more Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

Delivery program Part No. CF11.01.04.02 CF11.01.18.02 CF11.02.01.02 CF11.02.02.02(2) CF11.02.03.02 CF11.02.04.02 CF11.02.05.02 CF11.02.06.02 CF11.02.09.02 CF11.02.10.02 CF11.02.14.02 CF11.03.08.02 CF11.05.04.02 CF11.05.06.02 CF11.05.08.02 CF11.07.03.02 CF11.10.04.02 CF11.15.06.02 CF11.25.03.02

Number of cores and conductor nominal cross section [mm2] (4 x (2 x 0,14))C (18 x (2 x 0,14))C (1 x (2 x 0,25))C (2 x (2 x 0,25))C (3 x (2 x 0,25))C (4 x (2 x 0,25))C (5 x (2 x 0,25))C (6 x (2 x 0,25))C (9 x (2 x 0,25))C (10 x (2 x 0,25))C (14 x (2 x 0,25))C (8 x (2 x 0,34))C (4 x (2 x 0,5))C (6 x (2 x 0,5))C (8 x (2 x 0,5))C (3 x (2 x 0,75))C (4 x (2 x 1,0))C (6 x (2 x 1,5))C (3 x (2 x 2,5))C

External diameter approx. [mm] 7,0 14,0 6,0 6,5 8,0 9,0 9,0 10,0 12,5 13,0 13,5 12,5 10,0 11,5 14,0 11,0 12,0 17,0 16,5

Copper index [kg/km] 28 86 17 25 34 44 55 66 92 99 120 90 91 95 131 77 121 242 210

Weight [kg/km] 64 164 38 52 60 80 100 127 198 200 238 154 108 190 250 131 180 419 410

The chainflex® types marked with (2) are cables designed as a star-quad. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Delivery program Measuring system cables Page 164, CF211 (PVC) Page 170, CF111.D (TPE) Page 180, CF11.D (TPE)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

121


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 122

CF112 PUR 10 x d

PUR Data cable CF112 ● ● ● ● ● ● ● ●

Class 6.3.3 (6 maximum load requirements

for maximum load requirements PUR outer jacket double-shielded, twisted-pair oil-resistant and coolant-resistant notch-resistant PVC-free/halogen-free flame-retardant hydrolysis-resistant and microbe-resistant Conductor Core insulation Core stranding Core identification

Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality TPE mixture. 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Colour code in accordance with DIN 47100

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Intermediate jacket PUR mixture adapted to suit the requirements in energy chains®.

3 travel distance up to 100 m 3 oil-resistant)

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free Halogen-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

UL/CSA

Style 10493 and 20233, 300 V, 80°C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

CF112 PUR 10 x d

Element shield

Overall shield

T/R moved

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Anthracite gray (similar to RAL 7016) -20 °C to +80 °C, minimum bending radius 10 x d

T/R fixed

-40 °C to +80 °C, minimum bending radius 5 x d

Outer jacket

v max. unsupported/gliding 10 m/s, 5 m/s a max. 80 m/s2 Travel distance UV-resistant

Freely suspended and gliding travel distances up to 100 m, Class 3 High

Nominal voltage

300/300 V (following DIN VDE 0245).

Testing voltage

1500 V

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

Offshore

Typical application area ● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil indoor and outdoor applications with average sun radiation especially for freely suspended and gliding travel distances up to 100 m Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling, refrigerating sector

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] (2 x (2 x 0,25)C)C (3 x (2 x 0,25)C)C (4 x (2 x 0,25)C)C (5 x (2 x 0,25)C)C (6 x (2 x 0,25)C)C (2 x (2 x 0,5)C)C (3 x (2 x 0,5)C)C (4 x (2 x 0,5)C)C (5 x (2 x 0,5)C)C (6 x (2 x 0,5)C)C

CF112.02.02.02 CF112.02.03.02(1) CF112.02.04.02 CF112.02.05.02(1) CF112.02.06.02(1) CF112.05.02.02(1) CF112.05.03.02(1) CF112.05.04.02 CF112.05.05.02(1) CF112.05.06.02

External diameter approx. [mm] 9,5 10,0 11,0 11,5 12,0 11,5 12,0 12,5 13,5 14,5

Copper index [kg/km] 54 68 78 95 107 72 95 113 137 155

Weight [kg/km] 125 144 159 184 210 168 192 221 263 307

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

MUD-resistant following NEK 606 – status 2009.

Order example: CF112.02.04.02 – in your desired length (0,5 m steps) CF112 chainflex series .02 Code nominal cross section .04 Number of pairs .02 Identification pairs ®

Please use www.chainflex.eu/en/CF112 for your online order.

Image exemplary.

Delivery time 24h or today. eplan download, configurator

www.igus.eu/en/CF112

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Delivery time means time until shipping of goods.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

123


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 124

CF12 TPE 10 x d

Class 6.4.4 (6 maximum load requirements

TPE Data cable CF12 ● ● ● ● ● ● ●

for maximum load requirements TPE outer jacket double-shielded oil-resistant biooil-resistant PVC-free/halogen-free hydrolysis-resistant and microbe-resistant

Conductor Core insulation

Silicon-free

4 travel distance up to 400 m 4 oil-resistant)

CF12 TPE 10 x d

Halogen-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture.

Typical application area Core stranding Core identification Element shield Element jacket Inner jacket Overall shield

2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Cores < 0,5 mm2: Colour code in accordance with DIN 47100 Cores ≥ 0,5 mm2: Cores black with white numerals Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. TPE mixture adapted to suit the requirements in energy chains® over pair shield. TPE mixture adapted to suit the requirements in energy chains®.

T/R moved

Highly flexible shield consisting of galvanized steel wire braid. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Steel blue (similar to RAL 5011) -35 °C to +100 °C, minimum bending radius 10 x d

T/R fixed

-40 °C to +100 °C, minimum bending radius 5 x d

Outer jacket

v max. unsupported/gliding 10 m/s, 6 m/s a max. 100 m/s2 Travel distance UV-resistant

Freely suspended and gliding travel distances up to 400 m, Class 4 High

Nominal voltage

300/300 V (following DIN VDE 0245).

● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, outdoor cranes, low-temperature applications, for especially high EMC safety

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] (2 x (2 x 0,25)C)C (3 x (2 x 0,25)C)C (4 x (2 x 0,25)C)C (5 x (2 x 0,25)C)C (3 x (2 x 0,5)C)C (4 x (2 x 0,5)C)C (5 x (2 x 0,5)C)C (6 x (2 x 0,5)C)C (8 x (2 x 0,5)C)C (10 x (2 x 0,5)C)C (14 x (2 x 0,5)C)C (6 x (2 x 1,0)C)C

CF12.02.02.02 CF12.02.03.02(1) CF12.02.04.02 CF12.02.05.02 CF12.05.03.02 CF12.05.04.02 CF12.05.05.02 CF12.05.06.02 CF12.05.08.02 CF12.05.10.02 CF12.05.14.02 CF12.10.06.02

External diameter approx. [mm] 11,0 11,5 11,5 13,0 13,0 14,0 15,5 17,0 20,0 23,0 23,0 20,0

Copper index [kg/km] 27 40 61 93 66 88 110 132 177 221 309 198

Weight [kg/km] 152 172 179 220 210 255 297 360 477 548 723 542

(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF12.02.03.02 – in your desired length (0,5 m steps) CF12 chainflex series .02 Code nominal cross section .03 Number of pairs .02 Identification pairs

Image exemplary.

®

Testing voltage

1500 V

Please use www.chainflex.eu/en/CF12 for your online order.

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4.

Delivery time 24h or today.

eplan download, configurator

www.igus.eu/en/CF12

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Delivery time means time until shipping of goods.

Test data

Page 41 or www.igus.eu/en/test7

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

125


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 126

CFKoax1 TPE 10 x d

TPE Coax cable CFKoax1 ● ● ● ● ● ●

Class 6.4.4 (6 maximum load requirements

50/75 Ω coax cable for maximum load requirements TPE outer jacket oil-resistant biooil-resistant UV-resistant hydrolysis-resistant and microbe-resistant

4 travel distance up to 400 m 4 oil-resistant)

CFKoax1 TPE 10 x d

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1 The coax elements used in cables of the CF Koax1 series are comparable with a HF75-0.3/1.6 according to MIL-C-17/94-RG179 and thus fit in an RG179 plug!

Info

Typical application area Conductor Core insulation

Multi-wire; adapted in single-wire diameter and pitch length to suit the requirements in energy chains®. Special FEP-isolating mixture.

Core stranding

Cores stranded in one layer with especially short pitch length.

Identification

Coaxial elements

Element shield

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. TPE mixture adapted to suit the requirements in energy chains®.

Element jacket Outer jacket

Schedule Delivery Program

T/R moved

Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Steel blue (similar to RAL 5011) -35 °C to +100 °C, minimum bending radius 10 x d

T/R fixed

-40 °C to +100 °C, minimum bending radius 7,5 x d

v max. 10 m/s, 5 m/s unsupported/gliding a max. 100 m/s2 Travel distance

● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, indoor cranes, low-temperature applications

Delivery program Part No. CFKoax1.01 CFKoax1.05 New* CFKoax2.01

1 coaxial element 5 coaxial elements 1 coaxial element

External diameter approx. [mm] 4,5 10,0 4,5

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.

Part No.

CFKoax1.01 CFKoax1.05 CFKoax2.01

Freely suspended and gliding travel distances up to 400 m, Class 4

Number of cores

Characteristic wave impedance approx. [Ω] 75 75 50

Number of cores 1 coaxial element 5 coaxial elements 1 coaxial element

Copper index [kg/km] 9 47 7

Weight [kg/km] 25 135 23

*New in this catalogue.

Colour code

Colour Outer Jacket

red red, green, blue, white, black red

Steel blue Steel blue Jet black

Order example: CFKoax1.01 – in your desired length (0,5 m steps) CF Koax1 chainflex series .01 Number of coaxial elements ®

UV-resistant

High

Nominal voltage

300/300 V (following DIN VDE 0245).

Please use www.chainflex.eu/en/CFKOAX1 for your online order. Delivery time 24h or today.

1500 V

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following 2006/95/EG

Silicon-free CE

Image exemplary.

Delivery time means time until shipping of goods.

Testing voltage

eplan download, configurator

www.igus.eu/en/CFKOAX1

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Coax cables and other chainflex® cables in platform technology. e-chain®: System E4/4

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

127


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 128

Page

a max. [m/s2]

v max. [m/s] gliding

v max. [m/s] unsupported

Oil-resistant

Approvals and standards

Temperature, moved from/to [°C]

Min. bending radius, moved [factor x d]

Shield

Jacket

chainflex® cable

chainflex type

Torsion resistant

®

Bus cables

Bus cables

Selection chart for chainflex® bus cables

130

CFBUS.PVC

PVC

12,5

-5/ +70

2

30

134

CFBUS.PUR

PUR

12,5

-20/ +70

2

30

136

CFBUS

TPE

✔ 10-12,5

-35/ +70

10

6

100

138

CF11.LC

TPE

10

-35/ +70

10

6

100

144

CF11.LC.D

TPE

10

-35/ +70

10

6

100

146

CF14 CAT5

TPE

12,5

-35/ +70

10

6

100

148

129


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:56 Seite 130

chainflex® Bus cable

Profibus

150 Ohm

CFBUS.PVC.001 CFBUS.PUR.001 CFBUS.001 CF11.02.01.02.PBA.LC.D CFROBOT8.001 CFBUS.002 CF11.02.02.15.04.PBA.LC.D CFBUS.003 CF11.02.02.07.03.PBA.LC.D CF11.02.02.02.PBA.LC

(2 x 0,25)C (2 x 0,25)C (2 x 0,25)C (2 x 0,25)C (2 x 0,35)C 4 x 1,5 + (2 x 0,25)C 4 x 1,5 + (2 x 0,25)C 3 x 0,75+(2 x 0,25)C 3 x 0,75+(2 x 0,25)C (2 x (2 x 0,25))C

Interbus

100 Ohm

CFBUS.010 CF11.02.03.02.IB-S CFBUS.011 CF11.02.03.02.10.03.IB-S

(3 x (2 x 0,25))C (3 x (2 x 0,25))C (3 x 2 x 0,25 + 3 x 1,0)C (3 x 2 x 0,25 + 3 x 1,0)C

CAN-Bus

120 Ohm

CFBUS.PVC.021 CFBUS.PUR.021 CFBUS.021 CF11.05.01.02.LC CF11.05.01.02.LC.D CFBUS.020 CF11.02.02.02.LC.D CFBUS.PVC.022 CFBUS.PUR.022 CFBUS.022 CF11.05.02.02.LC CFROBOT8.022

(2 x 0,5)C (2 x 0,5)C (2 x 0,5)C (2 x 0,5)C (2 x 0,5)C (2 x (2 x 0,25)C (2 x (2 x 0,25)C (2 x (2 x 0,5))C (2 x (2 x 0,5))C (2 x (2 x 0,5))C (2 x (2 x 0,5))C (2 x (2 x 0,5))C

Device-Net

120 Ohm

CFBUS.030 CFBUS.031

((2 x AWG 24)C + 2 x AWG 22)C ((2 x AWG 18)C + 2 x AWG 15)C

Temperature, moved from/to [°C]

Class

12,5 x d 12,5 x d 10 x d 10 x d 10 x d 10 x d 10 x d 10 x d 10 x d 10 x d

PVC PUR TPE TPE PUR TPE TPE TPE TPE TPE

- 5 °C to +70 °C* - 20 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 20 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C

Class 4.1.2 Class 4.1.3 Class 6.4.4 Class 6.4.4 Class 6.1.3 Class 6.4.4 Class 6.4.4 Class 6.4.4 Class 6.4.4 Class 6.4.4

✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔

10 x d 10 x d 10 x d 10 x d

TPE TPE TPE TPE

- 35 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C

Class 6.4.4 Class 6.4.4 Class 6.4.4 Class 6.4.4

✔ ✔ ✔ ✔

12,5 x d 12,5 x d 10 x d 10 x d 10 x d 10 x d 10 x d 12,5 x d 12,5 x d 10 x d 10 x d 10 x d

PVC PUR TPE TPE TPE TPE TPE PVC PUR TPE TPE PUR

- 5 °C to +70 °C* - 20 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 5 °C to +70 °C* - 20 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 20 °C to +70 °C

Class 4.1.2 Class 4.1.3 Class 6.4.4 Class 6.4.4 Class 6.4.4 Class 6.4.4 Class 6.4.4 Class 4.1.2 Class 4.1.3 Class 6.4.4 Class 6.4.4 Class 6.1.3

✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔

10 x d 10 x d

TPE TPE

- 35 °C to +70 °C - 35 °C to +70 °C

Class 6.4.4 Class 6.4.4

✔ ✔

✔ ✔

✔ ✔ ✔

✔ ✔

✔ ✔ ✔ ✔ ✔ ✔

Approvals and standards

Page

Gliding

Number of cores and conductor Min. bending Jacket nominal cross section [mm2] radius, moved

Unsupported

Bus system/ chainflex® type

Halogen-free

Selection chainflex® bus cables UV-resistant

chainflex® Bus cable

✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ twisted ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔

134 136 138 146 244 138 146 138 146 144

✔ ✔ ✔ ✔

✔ ✔ ✔ ✔

138 144 138 144

✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ twisted

134 136 138 144 146 138 146 134 136 138 144 244

✔ ✔

138 138

✔ ✔

* -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2, +5 °C to +70 °C for use in energy chains® with > 50.000 cycles

More bus systems

130

Page 132

131


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:56 Seite 132

chainflex® Bus cable

Gliding

138

✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ twisted

138 148 138 148 138 148 134 136 138 138 244

138

Class 6.4.4

138

- 5 °C to +70 °C* - 20 °C to +70 °C - 35 °C to +70 °C -20 °C to +70 °C

Class 4.1.2 Class 4.1.3 Class 6.4.4 Class 6.1.3

✔ ✔ ✔ ✔

✔ ✔ ✔ twisted

✔ ✔ ✔

134 136 138 244

TPE TPE

- 35 °C to +70 °C - 35 °C to +70 °C

Class 6.4.4 Class 6.4.4

✔ ✔

✔ ✔

✔ ✔

138 138

TPE

- 35 °C to +70 °C

Class 6.4.4

138

Bus system/ chainflex® type

Number of cores and conductor Min. bending Jacket nominal cross section [mm2] radius, moved

CC-Link

110 Ohm

CFBUS.035

(3 x AWG 20)C

Ethernet CAT5/GigE

100 Ohm

CFBUS.040 CF14.02.02.02.CAT5 CFBUS.041 CF14.02.04.02.CAT5 CFBUS.042 CF14.02.05.02.CAT5 CFBUS.PVC.045 CFBUS.PUR.045 CFBUS.044 CFBUS.045 CFROBOT8.045

(2 x (2 x 0,25))C (2 x (2 x 0,25))C (4 x (2 x 0,25))C (4 x (2 x 0,25))C (5 x (2 x 0,25))C (5 x (2 x 0,25))C (4 x (2 x 0,15))C (4 x (2 x 0,15))C (4 x (2 x 0,15))C (4 x (2 x 0,15))C (4 x (2 x 0,15))C

Ethernet CAT6

100 Ohm

CFBUS.050

(4 x (2 x 0,14)C)C

FireWire

100 Ohm

CFBUS.055

(2 x (2 x 0,15)C+2 x (0,34)C)

Profinet

100 Ohm

CFBUS.PVC.060 CFBUS.PUR.060 CFBUS.060 CFROBOT8.060

(4 x 0,38)C (4 x 0,38)C (4 x 0,38)C (2 x (2 x 0,34))C

USB

90 Ohm

CFBUS.065 CFBUS.066

(2 x 0,5+1 x (2 x 0,08))C (2 x 0,5+1 x (2 x 0,24))C

DVI

100 Ohm

CFBUS.070

(4 x (2 x 0,08+2 x 0,08 + 3 x 0,08))C

Temperature, moved from/to [°C]

Class

10 x d

TPE

- 35 °C to +70 °C

Class 6.4.4

12,5 x d 12,5 x d 12,5 x d 12,5 x d 12,5 x d 12,5 x d 12,5 x d 12,5 x d 12,5 x d 12,5 x d 10 x d

TPE TPE TPE TPE TPE TPE PVC PUR TPE TPE PUR

- 35 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 5 °C to +70 °C* - 20 °C to +70 °C - 35 °C to +70 °C - 35 °C to +70 °C - 20 °C to +70 °C

Class 6.4.4 Class 6.3.4 Class 6.4.4 Class 6.3.4 Class 6.4.4 Class 6.3.4 Class 4.1.2 Class 4.1.3 Class 6.4.4 Class 6.4.4 Class 6.1.3

✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔

12,5 x d

TPE

- 35 °C to +70 °C

Class 6.4.4

12,5 x d

TPE

- 35 °C to +70 °C

12,5 x d 12,5 x d 12,5 x d 10 x d

PVC PUR TPE PUR

12,5 x d 12,5 x d 12,5 x d

Halogen-free

Unsupported

Selection chainflex® bus cables UV-resistant

chainflex® Bus cable

✔ ✔ ✔ ✔

Approvals and standards

Page

* -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2, +5 °C to +70 °C for use in energy chains® with > 50.000 cycles

More bus systems

132

Page 130

133


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:56 Seite 134

CFBUS.PVC PVC 12,5 x d

PVC Bus cable CFBUS.PVC ● ● ● ● ●

Class 4.1.2 (4 medium load requirements

for medium load requirements PVC outer jacket shielded oil-resistant flame-retardant

Conductor Core insulation

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). According to bus specification.

Core stranding

According to bus specification.

Core identification

According to bus specification Schedule Delivery Program Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in energy chains® (following DIN VDE 0281 Part 13). Colour: Red lilac (similar to RAL 4001) -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2, +5 °C to +70 °C for use in energy chains® with > 50.000 cycles, minimum bending radius 12,5 x d -20 °C to +70 °C, minimum bending radius 7,5 x d

Overall shield Outer jacket

T/R moved

T/R fixed v max. freely suspended a max.

2 m/s

Travel distance

Freely suspended travel distances, Class 1

UV-resistant

Medium

Nominal voltage

30 V

Testing voltage

500 V

Oil

Oil-resistant (following DIN EN 50363-4-1), Class 2.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Style 1598 and 2571, 30 V, 80 °C

UL/CSA

30 m/s2

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Typical application area ● ● ● ● ●

for medium load requirements light oil influence preferably indoor applications, but also outdoor ones at temperatures > 5 °C especially for freely suspended travel distances Bus connection cable for storage and retrieval units for high-bay warehouses, machining units/machine tools, handling, indoor cranes

Delivery program Part No.

Image exemplary.

Number of cores and conductor nominal cross section [mm2]

Profibus CFBUS.PVC.001 CAN-Bus CFBUS.PVC.021 CFBUS.PVC.022(2) Ethernet/CAT5/GigE CFBUS.PVC.045 Profinet CFBUS.PVC.060(16)

External diameter approx. [mm]

Copper index [kg/km]

Weight [kg/km]

(2x0,25)C

8,0

22

71

(2x0,5)C (2x(2x0,5))C

8,5 8,5

27 38

81 94

(4x(2x0,15))C

7,0

34

62

(4 x 0,38)C

7,0

38

67

®

The chainflex types marked with (2) are cables designed as a star-quad. (16) Colour outer jacket: Yellow green (similar to RAL 6018) Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Delivery program Characteristic Part No. wave impedance approx. [Ω] Profibus CFBUS.PVC.001 150 CAN-Bus CFBUS.PVC.021 120 CFBUS.PVC.022 120 Ethernet/CAT5/GigE CFBUS.PVC.045 100 Profinet CFBUS.PVC.060

eplan download, configurator

1 freely suspended 2 oil-resistant)

CFBUS.PVC PVC 12,5 x d

100

Number of cores Colour code and conductor nominal cross section [mm2] (2x0,25)C red, green (2x0,5)C (2x(2x0,5))C (4x(2x0,15))C

(4x0,38)C

white, brown white, green, brown, yellow (star-quad stranding) white-blue/blue, white-orange/orange, white-green/green, white-brown/brown white, yellow, blue, orange (star-quad stranding)

www.igus.eu/en/CFBUSPVC

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

135


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:56 Seite 136

CFBUS.PUR PUR 12,5 x d

PUR Bus cable CFBUS.PUR ● ● ● ● ● ● ● ●

Class 4.1.3 (4 medium load requirements

for medium load requirements PUR outer jacket shielded oil-resistant and coolant-resistant notch-resistant PVC-free/halogen-free flame-retardant hydrolysis-resistant and microbe-resistant Conductor

UL/CSA

Style 1598 and 20236, 30 V, 80 °C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

DESINA

According to VDW, DESINA standardisation

Lead free

Following 2011/55/EU (RoHS-II)

Core insulation

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). According to bus specification.

Core stranding

According to bus specification.

Typical application area

Core identification

● ● ● ● ●

T/R moved

According to bus specification Schedule Delivery Program Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Red lilac (similar to RAL 4001) -20 °C to +70 °C, minimum bending radius 12,5 x d

T/R fixed

-40 °C to +70 °C, minimum bending radius 7,5 x d

v max. freely suspended a max.

2 m/s

Travel distance

Freely suspended travel distances, Class 1

UV-resistant

Medium

Profibus CFBUS.PUR.001 CAN-Bus CFBUS.PUR.021 CFBUS.PUR.022(2) Ethernet/CAT5/GigE CFBUS.PUR.045 Profinet CFBUS.PUR.060(16)

Nominal voltage

30 V

Testing voltage

500 V

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

Offshore

MUD-resistant following NEK 606 – status 2009.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

Overall shield Outer jacket

Halogen-free

30 m/s2

for medium load requirements almost unlimited resistance to oil indoor and outdoor applications without direct sun radiation especially for freely suspended travel distances Bus connection cable for machining units/machine tools, low-temperature applications

Delivery program Part No.

Image exemplary.

Number of cores and conductor nominal cross section [mm2]

External diameter approx. [mm]

Copper index [kg/km]

Weight [kg/km]

(2x0,25)C

8,0

22

67

(2x0,5)C (2x(2x0,5))C

8,5 8,5

27 38

76 89

(4x(2x0,15))C

7,0

34

62

(4 x 0,38)C

7,0

38

64

The chainflex® types marked with (2) are cables designed as a star-quad. (16) Colour outer jacket: Yellow green (similar to RAL 6018) Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Delivery program Characteristic Part No. wave impedance approx. [Ω] Profibus CFBUS.PUR.001 150 CAN-Bus CFBUS.PUR.021 120 CFBUS.PUR.022 120 Ethernet/CAT5/GigE CFBUS.PUR.045 100 Profinet CFBUS.PUR.060

eplan download, configurator

1 freely suspended 3 oil-resistant)

CFBUS.PUR PUR 12,5 x d

100

Number of cores Colour code and conductor nominal cross section [mm2] (2x0,25)C red, green (2x0,5)C (2x(2x0,5))C (4x(2x0,15))C

(4x0,38)C

white, brown white, green, brown, yellow (star-quad stranding) white-blue/blue, white-orange/orange, white-green/green, white-brown/brown white, yellow, blue, orange (star-quad stranding)

www.igus.eu/en/CFBUSPUR

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

137


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:56 Seite 138

CFBUS TPE 10-12,5 x d

TPE Bus cable CFBUS ● ● ● ● ● ● ●

Class 6.4.4 (6 maximum load requirements

for maximum load requirements TPE outer jacket shielded oil-resistant 300 V UL for Ethernet biooil-resistant flame-retardant hydrolysis-resistant and microbe-resistant

NEW!

Conductor Core insulation

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). According to bus specification.

Core stranding

According to bus specification.

Core identification

According to bus specification Schedule Delivery Program TPE mixture adapted to suit the requirements in energy chains®.

Inner jacket Overall shield

T/R moved

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Red lilac (similar to RAL 4001) -35 °C to +70 °C, minimum bending radius 10-12,5 x d

T/R fixed

-40 °C to +70 °C, minimum bending radius 5 x d

Outer jacket

4 travel distance up to 400 m 4 oil-resistant)

CFBUS TPE 10-12,5 x d

UL/CSA

Style 1589 and 21371, 30 V, 80 °C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

DESINA

According to VDW, DESINA standardisation

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, tested by IPA according to standard 14644-1

Typical application area ● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil, also with bio-oils indoor and outdoor applications without direct sun radiation especially for freely suspended and gliding travel distances up to 400 m Bus connection cable for storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, indoor cranes, low-temperature applications

Test data

Page 34 or www.igus.eu/en/test3

v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2 Travel distance UV-resistant

Freely suspended and gliding travel distances up to 400 m, Class 4 Medium

Nominal voltage

30 V

Testing voltage

500 V

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Flame-retardant

Image exemplary.

Silicon-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).

eplan download, configurator

www.igus.eu/en/CFBUS

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

FireWire cable for moving energy supplies in digital camera technology.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

139


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:56 Seite 140

CFBUS TPE 10-12,5 x d

TPE Bus cable CFBUS

Class 6.4.4 (6 maximum load requirements

4 travel distance up to 400 m 4 oil-resistant)

CFBUS TPE 10-12,5 x d

Image exemplary.

Delivery program Part No.

Number of cores and External conductor nominal cross diameter 2 section [mm ] approx. [mm] Profibus (minimum bending radius 10 x d) Style 1589/21371, 30 V, 80°C CFBUS.001 (2x0,25)C 8,5 CFBUS.002 4x1,5+(2x0,25)C 12,5

Copper index [kg/km]

Weight [kg/km]

23 96

70 175

11,0

58

121

Interbus (minimum bending radius 10 x d) Style 1589/21371, 30 V, 80°C CFBUS.010 (3x(2x0,25))C 8,5 CFBUS.011 (3x2x0,25+3x1,0)C 10,0

42 74

83 135

CFBUS.003

3x0,75+(2x0,25)C

CAN-BUS/Fieldbus (minimum bending radius 10 x d) Style 1589/21371, 30 V, 80°C CFBUS.020(2) (2x(2x0,25))C 6,5 33 CFBUS.021 (2x0,5)C 8,5 36 (2) CFBUS.022 (2x(2x0,5))C 8,5 45 DeviceNet (minimum bending radius 10 x d) CFBUS.030(4) Drop ((2xAWG24)C+2xAWG22)C 7,5 33 CFBUS.031

Trunk ((2xAWG18)C+2xAWG15)C

11,5

96

66 77 83 65 110

CC-Link (minimum bending radius 10 x d) Style 1589/21371, 30 V, 80°C CFBUS.035 (3xAWG20)C 8,5 44 90 New* Ethernet/CAT5/GigE (minimum bending radius 12,5 x d) Style 10138/21235, 300 V, 80 °C – starting from manufacturing date 4/2012 CFBUS.040(2) (2x(2x0,25))C 7,0 33 43 CFBUS.041 (4x(2x0,25))C 10,0 46 101 CFBUS.042(1) (5x(2x0,25))C 10,5 53 106 CFBUS.044 (4x(2x0,15))C 8,0 35 79 CFBUS.045 (4x(2x0,15))C 8,0 35 79 Ethernet/CAT6 (minimum bending radius 12,5 x d) Style 1589/21371, 30 V, 80°C CFBUS.050 (4x(2x0,14)C)C 10,0 77

131

(1) Delivery time upon inquiry. (4) manufactured without inner jacket The chainflex® types marked with (2) are cables designed as a star-quad. Other types available on request. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalog.

Other types

Page 142

eplan download, configurator

www.igus.eu/en/CFBUS

950 types from stock no cutting costs ... 140

(for up to 10 cuts of the same type)

Delivery program Characteristic Core group Colour code Part No. wave impedance approx. [Ω] Profibus CFBUS.001 150 (2x0,25)C red, green CFBUS.002 150 4x1,5+ black with white numbers (2x0,25)C red/green CFBUS.003 150 3x0,75+ black, blue, green-yellow (2x0,25)C red/green Interbus CFBUS.010 100 (3x(2x0,25))C white/brown, green/yellow, gray/pink CFBUS.011 100 (3x1,0+ red, blue, green-yellow 3x(2x0,25))C white/brown, green/yellow, gray/pink CAN-BUS/Fieldbus CFBUS.020 120 (2x(2x0,25))C white, green, brown, yellow (star-quad stranding) CFBUS.021 120 (2x0,5)C white, brown CFBUS.022 120 (2x(2x0,5))C white, green, brown, yellow (star-quad stranding) DeviceNet CFBUS.030 Drop 120 (1x2xAWG24)+ white/blue (1x2xAWG22)C red/black CFBUS.031 Trunk 120 (1x2xAWG18)+ white/blue (1x2xAWG15)C red/black CC-Link CFBUS.035 110 (3xAWG20)C white, yellow, blue Ethernet/CAT5/GigE CFBUS.040 100 (2x(2x0,25))C white, green, brown, yellow (star-quad stranding) CFBUS.041 100 (4x(2x0,25))C white/brown, green/yellow, gray/pink, blue/red CFBUS.042 100 (5x(2x0,25))C white/brown, green/yellow, gray/pink, blue/red, black/violet CFBUS.044 100 (4x(2x0,15))C white/brown, green/yellow, gray/pink, blue/red CFBUS.045 100 (4x(2x0,15))C white-blue/blue, white-orange/orange, white-green/green, white-brown/brown Ethernet/CAT6 CFBUS.050 100 (4x(2x0,14)C)C white, blue, white, orange, white, green, white, brown

Technical note The USB, FireWire and GigE-cables shown on these pages were developed for the ambitious industrial usage in e-chains®. High proofness to oil and lubricants is as secured as protection against electromagnetical interferences. This high mechanical service life was reached with the usage of high quality materials which even care for the electrical safeness. In single cases communication errors can occur, if very different hardware and software is combined. We recommend tests with all components and the cables before starting serial production, to get the proove for a perfect running system. Of course we support you with the details of these electrical tests. Just give us a call!

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

141


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:56 Seite 142

CFBUS TPE 10-12,5 x d

TPE Bus cable CFBUS

Class 6.4.4 (6 maximum load requirements

4 travel distance up to 400 m 4 oil-resistant)

CFBUS TPE 10-12,5 x d

Image exemplary.

Delivery program Part No.

Number of cores and External conductor nominal cross diameter 2 section [mm ] approx. [mm] FireWire (minimum bending radius 12,5 x d) Style 1589/21371, 30 V, 80°C CFBUS.055 (2x(2x0,15)C+2x(0,34)C) 7,5

Copper index [kg/km]

Weight [kg/km]

42

81

Profinet (minimum bending radius 12,5 x d) Style 10138/21235, 300 V, 80°C – starting from manufacturing date 4/2012 CFBUS.060(16) (4x0,38)C 7,5 37 71 USB (minimum bending radius 12,5 x d) Style 1589/21371, 30 V, 80°C CFBUS.065 (2x0,5+1x(2x0,08))C 5,0 26 45 CFBUS.066

(2x0,5+1x(2x0,24))C

6,0

32

56

DVI (minimum bending radius 12,5 x d) Style 1589/21371, 30 V, 80°C CFBUS.070 (4x(2x0,08)C+1x2x0,08+3x0,08)C 9

33

92

(16) Colour outer jacket: Yellow green (similar to RAL 6018) Other types available on request. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Delivery program Characteristic Core group Colour code Part No. wave impedance approx. [Ω] FireWire CFBUS.055 100 2x(2x0,15)C+ orange/blue, green/red 2x(0,34)C black, white Profinet CFBUS.060 100 (4x0,38)C white, yellow, blue, orange (star-quad stranding) USB CFBUS.065 90 2x0,5 red, black 2x0,08 white/green CFBUS.066 90 2x0,5 red, black 2x0,24 white/green DVI CFBUS.070 100 (4x(2x0,08+ 4 x white/yellow with elementjacket in blue, black, white, red 2x0,08+3x0,08))C white/brown, green, yellow, gray

Order example: CFBUS.060 – in your desired length (0,5 m steps) CFBUS chainflex series .060 Code BUS-type ®

Other types

Page 140

Please use www.chainflex.eu/en/CFBUS for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.

Technical note

eplan download, configurator

www.igus.eu/en/CFBUS

950 types from stock no cutting costs ... 142

(for up to 10 cuts of the same type)

The USB, FireWire and GigE-cables shown on these pages were developed for the ambitious industrial usage in e-chains®. High proofness to oil and lubricants is as secured as protection against electromagnetical interferences. This high mechanical service life was reached with the usage of high quality materials which even care for the electrical safeness. In single cases communication errors can occur, if very different hardware and software is combined. We recommend tests with all components and the cables before starting serial production, to get the proove for a perfect running system. Of course we support you with the details of these electrical tests. Just give us a call!

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

143


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:56 Seite 144

CF11.LC TPE 10 x d

TPE Bus cable CF11.LC (low capacitance) ● ● ● ● ● ● ● ●

Class 6.4.4 (6 maximum load requirements

for maximum load requirements TPE outer jacket shielded oil-resistant biooil-resistant PVC-free/halogen-free UV-resistant hydrolysis-resistant and microbe-resistant

4 travel distance up to 400 m 4 oil-resistant)

CF11.LC TPE 10 x d

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

Typical application area Conductor Core insulation

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). According to bus specification.

Core stranding

According to bus specification.

Core identification

According to bus specification Schedule Delivery Program TPE mixture adapted to suit the requirements in energy chains®.

Inner jacket Overall shield

T/R moved

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Steel blue (similar to RAL 5011) -35 °C to +70 °C, minimum bending radius 10 x d

T/R fixed

-40 °C to +70 °C, minimum bending radius 5 x d

Outer jacket

● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m Bus connection cable for storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, outdoor cranes, low-temperature applications

Delivery program Part No. Interbus CF11.02.03.02.IB-S CF11.02.03.02.10.03.IB-S CAN-Bus CF11.05.01.02.LC CF11.05.02.02.LC(2) Profibus CF11.02.02.02.PBA.LC(2)

Number of cores and conductor nominal cross section [mm2] (3x(2x0,25))C (3x2x0,25+3x1,0)C

External diameter approx. [mm] 8,5 10,0

Copper index [kg/km] 42 74

Weight [kg/km]

(2x0,5)C (2x(2x0,5))C

8,5 8,5

36 45

77 83

(2x(2x0,25))C

8,5

33

80

83 135

®

The chainflex types marked with (2) are cables designed as a star-quad. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2 Travel distance UV-resistant

Freely suspended and gliding travel distances up to 400 m, Class 4 High

Nominal voltage

30 V

Testing voltage

500 V

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

Silicon-free Halogen-free

Delivery program Characteristic Number of cores and Part No. wave impedance conductor nominal Interbus approx. [Ω] cross section [mm2] CF11.02.03.02.IB-S 100 (3x(2x0,25))C CF11.02.03.02.10.03.IB-S 100 (3x2x0,25+ 3x1,0)C CAN-Bus CF11.05.01.02.LC 120 (2x0,5)C CF11.05.02.02.LC 120 (2x(2x0,5))C Profibus CF11.02.02.02.PBA.LC 150 (2x(2x0,25))C

Colour code

white/brown, green/yellow, gray/pink white/brown, green/yellow, gray/pink red, blue, green-yellow white, brown white, green, brown, yellow (star-quad stranding) green, yellow , red, brown (star-quad stranding)

Order example: CF11.02.03.02.IB-S – in your desired length (0,5 m steps) CF11.LC chainflex series .02 Code nominal cross section .03 Number of pairs .02 Identification pairs .IB-S Special identification ®

Image exemplary.

Please use www.chainflex.eu/en/CF11LC for your online order.

eplan download, configurator

www.igus.eu/en/CF11LC

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Delivery time 24h or today. Delivery time means time until shipping of goods.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

145


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:56 Seite 146

CF11.LC.D TPE 10 x d

TPE Bus cable CF11.LC.D (low capacitance) ● ● ● ● ● ● ●

Class 6.4.4 (6 maximum load requirements

for maximum load requirements TPE outer jacket shielded PVC-free/halogen-free oil-resistant biooil-resistant hydrolysis-resistant and microbe-resistant

Conductor Core insulation

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). According to bus specification.

Core stranding

According to bus specification.

Core identification

According to bus specification Schedule Delivery Program TPE mixture adapted to suit the requirements in energy chains®.

Inner jacket Overall shield Outer jacket

T/R moved T/R fixed

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Red lilac (similar to RAL 4001) -35 °C to +70 °C, minimum bending radius 10 x d -40 °C to +70 °C, minimum bending radius 5 x d

UV-resistant

Freely suspended and gliding travel distances up to 400 m, Class 4 Medium

Nominal voltage

30 V

Testing voltage

500 V

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

Silicon-free Halogen-free

CE

Following 2006/95/EG

DESINA

According to VDW, DESINA standardisation

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

Typical application area ● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil, also with bio-oils indoor and outdoor applications without direct sun radiation especially for freely suspended and gliding travel distances up to 400 m Bus connection cable for storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, indoor cranes, low-temperature applications

Delivery program Number of cores and Part No. conductor nominal Profibus cross section [mm2] CF11.02.01.02.PBA.LC.D (2x0,25)C CF11.02.02.07.03.PBA.LC.D 3x0,75+(2x0,25)C CF11.02.02.15.04.PBA.LC.D 4x1,5+(2x0,25)C CAN-Bus CF11.02.02.02.LC.D(2) (2x(2x0,25))C CF11.05.01.02.LC.D (2x0,5)C

External diameter approx. [mm] 8,5 11,0 12,5

Copper index [kg/km] 23 58 96

Weight [kg/km]

6,5 8,5

33 36

66 77

70 121 175

The chainflex® types marked with (2) are cables designed as a star-quad. Other types available on request. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2 Travel distance

4 travel distance up to 400 m 4 oil-resistant)

CF11.LC.D TPE 10 x d

Delivery program Characteristic Number of cores and Part No. wave impedance conductor nominal Profibus approx. [Ω] cross section [mm2] CF11.02.01.02.PBA.LC.D 150 (2x0,25)C CF11.02.02.07.03.PBA.LC.D 150 3x0,75+ (2x0,25)C CF11.02.02.15.04.PBA.LC.D 150 4x1,5+ (2x0,25)C CAN-Bus CF11.02.02.02.LC.D 120 (2x(2x0,25))C CF11.05.01.02.LC.D 120 (2x0,5)C

Colour code red/green black, blue, green-yellow red/green black with white numbers red/green white, green, brown, yellow (star-quad stranding) white/brown

Order example: CF11.02.01.02.PBA.LC.D – in your desired length (0,5 m steps) CF11.LC.D chainflex series .02 Code nominal cross section .01 Number of pairs .02 Identification pairs .PBA.LC.D Special identification ®

Image exemplary.

Please use www.chainflex.eu/en/CF11LCD for your online order. eplan download, configurator

www.igus.eu/en/CF11LCD

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Delivery time 24h or today. Delivery time means time until shipping of goods.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

147


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:56 Seite 148

CF14 CAT5 TPE 12,5 x d

TPE Bus cable CF14CAT5 ● ● ● ● ● ● ●

Class 6.3.4 (6 maximum load requirements

Ethernet special cable for heavy-duty use TPE outer jacket oil-resistant biooil-resistant PVC-free/halogen-free UV-resistant hydrolysis-resistant and microbe-resistant

Conductor

CE

Following 2006/95/EG

DESINA

According to VDW, DESINA standardisation

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

19-wire conductor consisting of bare copper wires in especially bending-resistant braiding quality. Special PP-isolating mixture.

Typical application area

Core identification

2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Colour code in accordance with DIN 47100

● ● ● ● ●

Inner jacket

TPE mixture adapted to suit the requirements in energy chains®.

Overall shield

T/R moved

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Red lilac (similar to RAL 4001) -35 °C to +70 °C, minimum bending radius 12,5 x d

T/R fixed

-40 °C to +70 °C, minimum bending radius 7,5 x d

Core insulation Core stranding

Outer jacket

v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2 Travel distance UV-resistant

Freely suspended and gliding travel distances up to 100 m, Class 3 Medium

Nominal voltage

30 V

Testing voltage

500 V

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

Silicon-free Halogen-free

3 travel distance up to 100 m 4 oil-resistant)

CF14 CAT5 TPE 12,5 x d

for maximum load requirements almost unlimited resistance to oil, also with bio-oils indoor and outdoor applications without direct sun radiation especially for freely suspended and gliding travel distances up to 100 m Ethernet cable for Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, indoor cranes, low-temperature applications

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2]

Ethernet CAT5 New* CF14.01.04.02.CAT5 CF14.02.02.02.CAT5(2) CF14.02.04.02.CAT5 CF14.02.05.02.CAT5

External diameter approx. [mm]

(4x(2x0,14))C (2x(2x0,25))C (4x(2x0,25))C (5x(2x0,25))C

8,5 7,5 10,0 10,5

Copper index [kg/km]

Weight [kg/km]

39 33 46 53

75 43 101 106

The chainflex® types marked with (2) are cables designed as a star-quad. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalog.

Delivery program Characteristic Part No. wave impedance approx. [Ω] Ethernet CAT5 CF14.01.04.02.CAT5 100 CF14.02.02.02.CAT5 100 CF14.02.04.02.CAT5 100 CF14.02.05.02.CAT5 100

Number of cores Colour code and conductor nominal cross section [mm2] (4x(2x0,14))C white/brown, green/yellow, gray/pink, blue/red (2x(2x0,25))C white, green, brown, yellow (star-quad stranding) (4x(2x0,25))C white/brown, green/yellow, gray/pink, blue/red (5x(2x0,25))C white/brown, green/yellow, gray/pink, blue/red, black/violet

Order example: CF14.02.02.02.CAT5 – in your desired length (0,5 m steps) CF14 CAT5 chainflex series .02 Code nominal cross section .02 Number of pairs .02 Identification pairs .CAT5 CAT5 identification ®

Please use www.chainflex.eu/en/CF14 for your online order. Delivery time 24h or today.

Image exemplary.

Delivery time means time until shipping of goods.

eplan download, configurator

www.igus.eu/en/CF14

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Test data Page 32 or www.igus.eu/en/test2 More CAT5/CAT6 cables Page 140, CFBUS

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

149


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:57 Seite 150

Page

a max. [m/s2]

v max. [m/s] gliding

v max. [m/s] unsupported

Oil-resistant

Approvals and standards

Temperature, moved from/to [°C]

Min. bending radius, moved [factor x d]

Shield

Jacket

chainflex® cable

Fibre optic cables

chainflex type

Torsion resistant

®

Fibre optic cables* Information fibre optic cables

154

CFLK**

PUR

CFLG.2H

phase-out model, is replaced by CFLG.LB

CFLG.LB***

TPE

5

CFLG. G***

TPE

15

12,5

-20/ +70

10

5

20

156

-40/ +60

10

6

20

160

-40/ +60

10

6

20

162

* CFROBOT5, torsionable fibre optic cables ** POF-Fibre/plastic FOC *** Multimode/gradient fibres

Page 248

151


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:57 Seite 152

Info

Info

The safest and often cheapest way to transfer data to machines and plant.

Fault-free communication between all systems in machines and plant that is becoming more and more complex all the time should be a matter of course these days. However, many plant manufacturers or operators have major EMC problems that occur sporadically or even only years later. These problems are often based on conventional bus cables that either have insufficient or unreliable shielding. Alongside igus® chainflex® bus cables that already prevent these problems to a large extent, chainflex® glass fibre optic cables provide further advantages for even greater data safety. Fibre optic cables (FOC) do not require a braided shielding that is susceptible to mechanical damage as EMC protection, and are insensitive to EMC on account of their very nature, since industrial conventional interference fields do not have any effect on light signals. In addition, fibre optic cables can be used independently of the system, since a special bus cable is not required for every bus system, rather one FOC type can usually be used to operate any bus system providing the bus system manufacturer provides respective FOC converters.

Important fibre types: ● Multi-mode fibres 50/125 µm 62,5/125 µm The ideal fibre for large data volumes and longer transmission lengths in the field of automation. On account of the very low output attenuation (0.8-3 db/km per fibre and light wave length) of these fibre types, transmission lengths of several hundred metres can be realised quite easily. ● POF (Plastic fibres) 980/1000 µm The ideal and low-cost fibre for short transmission paths. On account of the high output attenuation of the fibre type of 160-230 dB/km, lengths over 15 mm must be avoided in permanent-motion energy chains®.

chainflex® FOC offer the operator the following advantages: 1. Greater data security thanks to ● FOC-typical better transmission characteristics ● Greater possible transmission lengths of several 100 m ● Greater possible data volumes thanks to lower attenuation values ● Maximum EMC protection for the data transmitted ● Future-proof installation (no cable replacement with new bus systems)

Test data Page 38 or www.igus.eu/en/test5

2. Greater mechanical protection through ● The FOC designed for permanent mechanical movement ● The igus®-typical highly abrasion-proof and chemical resistant sheathing materials ● The special chainflex® design concept (tested at 30 million cycles without a significant increase in attenuation) 3. Future-oriented cost reduction through ● Bus-independent bus cable wiring ● Longer service life in e-chains® ● Extendable without transmission limits

● PCF (Polymer Cladded Fibre) 200/230 µm The ideal compromise for POF fibre. This plasticcoated quartz glass fibre is a viable alternative for many terminal devices that have been designed for POF. This means greater transmission lengths (100 m and more) are possible without the original POF terminal devices having to be replaced.

The large number of fibre optic cables in industrial data transmission is also much more manageable than the large number of different field or high-speed buses which require a separate cable for each bus. Thus the following fibre types can be used for industrial data communication, completely independently of the type of field bus used. The fibre type and number depends only on which converters are used and which fibre type the respective manufacturer prescribes. The fibres are defined on the basis of diameter and result in a clear and limited choice.

950 types from stock no cutting costs ... 152

(for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

153


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:57 Seite 154

CFLK PUR 12,5 x d

PUR Fibre optic cable (FOC) CFLK ● POF fibres for high load requirements and interference-free transmission ● PUR outer jacket ● oil-resistant and coolant-resistant

Fibre cable

Class 5.1.3 (5 high load requirements

CFLK PUR 12,5 x d

1 freely suspended 3 oil-resistant)

Typical application area ● ● ● ● ● ●

for high load requirements maximum EMC protection almost unlimited resistance to oil preferably indoor applications especially for freely suspended and gliding travel distances up to 15 m Wood/stone processing, packaging industry, supply system, handling, adjusting equipment

980/1000 µm fibre with PE isolation.

Core stranding

POF fibre with stranded high-tensile plastic reinforcement.

Delivery program Part No.

Core identification

Core black.

CFLK.L1.01

Number of fibres

1

Fibre diameter approx. [µm] 980/1000

External diameter approx. [mm] 6,0

Weight [kg/km] 25

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.

Outer jacket

T/R moved

Low-adhesion mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Red lilac (similar to RAL 4001) -20 °C to +70 °C, minimum bending radius 12,5 x d

T/R fixed

-25 °C to +70 °C, minimum bending radius 7,5 x d

Part No.

CFLK.L1.01

Image exemplary.

Fibres identification black

®

Please use www.chainflex.eu/en/CFLK for your online order.

Freely suspended and gliding travel distances up to 15 m, Class 1

UV-resistant

Medium

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

Silicon-free Halogen-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

eplan download, configurator

Attenuation with 650 nm [dB/km] 200

Order example: CFLK.L1.01 – in your desired length (0,5 m steps) CFLK chainflex series .L1 Type of fibres .01 Number of cores

v max. 10 m/s, 5 m/s unsupported/gliding a max. 20 m/s2 Travel distance

Bandwidth with 650 nm [MHz x km] 40

www.igus.eu/en/CFLK

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Delivery time 24h or today. Delivery time means time until shipping of goods.

Woodworkingmachines with e-chains® and chainflex® cables

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

155


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:57 Seite 156

CFLG.LB TPE 5xd

TPE Fibre optic cable (FOC) CFLG.LB ● ● ● ● ● ● ●

Gradient glass-fibre cable for maximum load requirements TPE outer jacket metal-free oil-resistant low-temperature-flexible up to -40 °C PVC-free/halogen-free UV-resistant

Fibre cable Core stranding Core identification Overall shield

50/125 µm, 62.5/125 µm special fixed wire elements with aramide strain relief. FOC cores stranded with high-tensile aramide dampers with especially short pitch length. Cores blue with white numerals. Extremely bending-resistant aramid braid for torsion protection.

Class 7.3.4 (7 maximum load requirements

3 travel distance up to 100 m and more 4 oil-resistant)

CFLG.LB TPE 5xd

Typical application area ● ● ● ● ● ●

for maximum load requirements at 5 x d maximum EMC protection, with high transmission qualities in terms of glass-specific requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications for freely suspended and gliding travel distances up to 100 m and more Storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling, semiconductor insertion, refrigerating sector

Delivery program Part No.

Number of fibres

CFLG.2LB.62,5/125 CFLG.2LB.50/125

2 2

Fibre diameter approx. [µm] 62,5/125 50/125

External diameter approx. [mm] 8,5 8,5

Weight [kg/km] 47 47

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.

Outer jacket

T/R moved

Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Jet black (similar to RAL 9005) -40 °C to +60 °C, minimum bending radius 5 x d

T/R fixed

-40 °C to +60 °C, minimum bending radius 5 x d

UV-resistant Oil

Image exemplary.

®

Please use www.chainflex.eu/en/CFLGLB for your online order.

Freely suspended and gliding travel distances up to 100 m and more, Class 3 High

Halogen-free

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Silicon-free

eplan download, configurator

CFLG.2LB.62,5/125 CFLG.2LB.50/125

Bandwidth Attenuation Bandwidth Attenuation Fibres with 850 nm with 850 nm with 1300 nm with 1300 nm identification [MHz x km] [dB/km] [MHz x km] [dB/km] 160 - 200 3,2 200 - 500 0,9 orange with white numbers 200 - 600 2,5 - 3,5 600 - 1200 0,7 - 1,5 blue with white numbers

Order example: CFLG.2LB.50/125 – in your desired length (0,5 m steps) CFLG.2LB chainflex series .50/125 Type of fibres

v max. 10 m/s, 6 m/s unsupported/gliding a max. 20 m/s2 Travel distance

Part No.

Delivery time 24h or today. Delivery time means time until shipping of goods.

www.igus.eu/en/CFLGLB

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

157


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:57 Seite 158

CFLG.G TPE 15 x d

TPE Fibre optic cable (FOC) CFLG.G ● ● ● ● ●

Gradient glass-fibre cable for maximum load requirements TPE outer jacket PVC-free/halogen-free low-temperature-flexible to -40 °C hydrolysis-resistant and microbe-resistant

Fibre cable Stranding Identification Outer jacket

T/R moved

Class 7.4.4 (7 maximum load requirements Typical application area ● ● ● ● ● ●

for maximum load requirements maximum EMC protection, with high transmission qualities in terms of glass-specific requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications only for freely suspended and gliding travel distances up to 500 m and more Outdoor ship to shore, crane applications, conveyer technology, low-temperature applications

50/125 µm, 62,5/125 µm fibres in gel-filled hollow cores. Stranded GRP rods with integrated torsion protection braid in the outer jacket over gel-filled fibre sheath. Fibres Schedule Delivery Program Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Jet black (similar to RAL 9005) -40 °C to +60 °C, minimum bending radius 15 x d

Delivery program Part No.

Number of fibres

CFLG.6G.62,5/125.TC CFLG.12G.62,5/125.TC CFLG.6G.50/125.TC CFLG.12G.50/125.TC

6 12 6 12

Travel distance UV-resistant Oil

CFLG.6G.62,5/125.TC CFLG.12G.62,5/125.TC CFLG.6G.50/125.TC CFLG.12G.50/125.TC

Freely suspended and gliding travel distances up to 500 m and more, Class 4 High

Halogen-free

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Silicon-free

Bandwidth with 850 nm [MHz x km] 160 - 200 160 - 200 200 - 600 200 - 600

-40 °C to +60 °C, minimum bending radius 8,5 x d

v max. 10 m/s, 6 m/s unsupported/gliding a max. 20 m/s2

Fibre diameter approx. [µm] 62,5/125 62,5/125 50/125 50/125

External diameter approx. [mm] 11,5 11,5 11,5 11,5

Weight [kg/km] 110 110 110 110

Other number of fibres on request. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.

Part No. T/R fixed

4 travel distance up to 500 m and more 4 oil-resistant)

CFLG.G TPE 15 x d

Attenuation with 850 nm [dB/km] 3,2 3,2 2,5 - 3,5 2,5 - 3,5

Bandwidth with 1300 nm [MHz x km] 200 - 500 200 - 500 600 - 1200 600 - 1200

Attenuation with 1300 nm [dB/km] 0,9 0,9 0,7 - 1,5 0,7 - 1,5

Part No.

Fibres identification

Hollow core identification

CFLG.6G.62,5/125.TC CFLG.12G.62,5/125.TC

ecru, yellow, green, red, violet, blue ecru, yellow, green, red, violet, blue, lightblue, gray, brown, black, orange, pink ecru, yellow, green, red, violet, blue ecru, yellow, green, red, violet, blue, lightblue, gray, brown, black, orange, pink

orange orange

CFLG.6G.50/125.TC CFLG.12G.50/125.TC

blue blue

Order example: CFLG.6G.62,5/125.TC – in your desired length (0,5 m steps) CFLG.G chainflex series .6G Number of cores .62,5/125 Type of fibres .TC Special identification ®

Please use www.chainflex.eu/en/CFLGGT for your online order. Delivery time 24h or today.

Image exemplary.

Delivery time means time until shipping of goods.

eplan download, configurator

www.igus.eu/en/CFLGGT

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Test data

Page 46 or www.igus.eu/en/test10

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

159


Page

a max. [m/s2]

v max. [m/s] gliding

v max. [m/s] unsupported

Oiil-resistant

Approvals and standards

Temperature, moved from/to [°C]

Min. bending radius, moved [factor x d]

Shield

Jacket

chainflex type

Torsion resistant

®

chainflex® cable

Measuring system cables

EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:57 Seite 160

Measuring system cables Selection chart for chainflex® measuring system cables

162

CF211

PVC

10

-5/ +70

5

CF111.D

PUR

12

-35/ +100

2

CF113.D

PUR

10

-20/ +80

5

CF11.D

TPE

10

-35/ +100

10

3

50

164

30

170

3

50

174

6

100

180

161


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:57 Seite 162

chainflex® Measuring system cables

Selection chart for chainflex® measuring system cables

chainflex®-series CF211.yyy Drive Technology Number of cores and Class 5.3.2 System conductor nominal Jacket PVC 2 cross section [mm ] Page 164

CF111.yyy.D CF113.yyy.D CF11.yyy.D 4.1.3 6.3.3 6.4.4 PUR PUR TPE 170 174 180

B&R CFxxx.027.D CFxxx.027.D

(5x(2x0,14)+2x0,5)C

(4x(2x0,34)+4x0,5)C

(3x(2x0,14)C+(4x0,14)+(2x0,5))C (4x(2x0,34)+4x0,5)C

✔ ✔

✔ ✔

✔ ✔

✔ ✔

(4x(2x0,25)+2x0,5)C

Control Techniques CFxxx.001.D CFxxx.011.D

ELAU CFxxx.009.D

Fagor CFxxx.004.D CFxxx.015.D

(2x(2x2x0,14)+(4x0,14)C+(4x0,5))C (4x(2x0,14)+4x0,5)C

✔ ✔

✔ ✔

✔ ✔

(3x(2x0,5+2x0,25)+(4x0,25))C (5x0,5+(2x0,25))C

✔ ✔

✔ ✔

✔ ✔

(2x(2x2x0,14)+(4x0,14)C+(4x0,5))C (4x(2x0,14)+4x0,5)C (4x(2x0,14)+4x0,5)C (3x(2x0,14)C+(2x0,5)C)C

✔ ✔ ✔ ✔

✔ ✔ ✔ ✔

✔ ✔

✔ ✔

✔ ✔ ✔ ✔ ✔ ✔

✔ ✔ ✔ ✔ ✔ ✔

✔ ✔ ✔

✔ ✔ ✔

FANUC CFxxx.021.D CFxxx.022.D

Jetter CFxxx.002.D CFxxx.025.D

(3x(2x0,14)C+(2x0,5C))C (3x(2x0,14)C+(2x0,5)C)C

(3x(2x0,14)C+2x(0,5)C)C (4x(2x0,25)+2x1,0)C (3x(2x0,14)C+(2x0,5)C)C 3x(2x0,14)C+(3x0,14)C 4x(2x0,14)C+2x(1,0)C 3x(2x0,14)C+(4x0,14)C+2x(2x0,5)C

✔ ✔

Lenze CFxxx.002.D CFxxx.010.D CFxxx.025.D CFxxx.032.D CFxxx.033.D CFxxx.034.D

LTi DRiVES CFxxx.004.D CFxxx.009.D CFxxx.010.D

CFxxx.001.D CFxxx.008.D CFxxx.009.D CFxxx.010.D CFxxx.018.D

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

✔ ✔ ✔ ✔ ✔

(2x(2x2x0,14)+(4x0,14)C+(4x0,5))C (4x(2x0,25)+2x0,5)C (4x(2x0,25)+2x1,0)C

✔ ✔ ✔

(3x(2x0,25))C (4x(2x0,25)+2x0,5)C (4x(2x0,25)+2x1,0)C (2x(2x0,25)+2x0,5)C

✔ ✔ ✔

✔ ✔ ✔ ✔

(4x(2x0,25)+2x0,5)C (4x(2x0,25)+2x1,0)C (4x(2x0,14)+(4x0,14)C+4x1,0)C (2x(2x0,25)+2x0,5)C (3x(2x0,25)C+(3x0,25)+2x1,0)C

✔ ✔ ✔ ✔ ✔

✔ ✔ ✔ ✔ ✔

✔ ✔ ✔ ✔ ✔

(4x(2x0,25)+2x0,5)C

(3x(2x0,14)C+(4x0,14)+(2x0,5))C (3x(2x0,14)C+2x(0,5)C)C (3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C (4x(2x0,34)+4x0,5)C (2x(2x0,15)+(2x0,38))C

✔ ✔ ✔ ✔

✔ ✔ ✔ ✔ ✔

✔ ✔ ✔ ✔

✔ ✔ ✔ ✔ ✔

✔ ✔ ✔ ✔ ✔

✔ ✔ ✔ ✔ ✔

✔ ✔ ✔ ✔ ✔

Rexroth CFxxx.009.D CFxxx.010.D CFxxx.017.D CFxxx.018.D CFxxx.019.D

SEW CFxxx.009.D

Heidenhain CFxxx.004.D CFxxx.005.D CFxxx.015.D CFxxx.025.D

CF111.yyy.D CF113.yyy.D CF11.yyy.D 4.1.3 6.3.3 6.4.4 PUR PUR TPE 170 174 180

Omron

Berger Lahr CFxxx.011.D

chainflex®-series CF211.yyy Drive Technology Number of cores and Class 5.3.2 System conductor nominal Jacket PVC 2 cross section [mm ] Page 164

NUM (5x(2x0,14)+2x0,5)C

Baumüller

162

chainflex® Measuring system cables

Siemens CFxxx.001.D CFxxx.002.D CFxxx.006.D CFxxx.011.D CFxxx.028.D

✔ ✔ ✔

Stöber CFxxx.008.D CFxxx.009.D CFxxx.011.D CFxxx.016.D CFxxx.021.D

(3x(2x0,25))C (4x(2x0,25)+2x0,5)C (4x(2x0,34)+4x0,5)C (3x(2x0,25)C)C (3x(2x0,5+2x0,25)+(4x0,25))C

✔ ✔ ✔

✔ ✔

Altri cavi chainflex® CFxxx.003.D CFxxx.007.D CFxxx.012.D CFxxx.013.D CFxxx.014.D CFxxx.035.D

(3x(2x0,14)+2x1,0)C (2x2x0,34)C (3x(2x0,14)C+(3x0,14)C+6x0,14+2x0,5)C (3x(2x0,14)C+2x0,5)C (4x(2x0,25)C+2x0,5)C (4x(2x0,25)C+2x(2x0,5))C

✔ ✔

163


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:57 Seite 164

CF211 PVC 10 x d

PVC Measuring system cable CF211 ● ● ● ● ●

for high load requirements PVC outer jacket shielded oil-resistant flame-retardant

Conductor Core insulation Core stranding

Class 5.3.2 (5 high load requirements

NEW! Outer jacket in green

Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality PP mixture.

According to measuring system specification Schedule Delivery Program Element shield Extremely bending-resistant, tinned copper cover. Coverage approx. 90% optical. Element jacket TPE mixture adapted to suit the requirements in energy chains® over pair shield. Intermediate jacket Foil taping over the external layer.

Outer jacket

T/R moved

T/R fixed

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free UL/CSA

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Style 1589 and 2502, 30 V, 80 °C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1.

According to measuring system specification.

Core identification

Overall shield

3 travel distance up to 100 m 2 oil-resistant)

CF211 PVC 10 x d

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in energy chains® (following DIN VDE 0281 Part 13). Colour: Silver gray (similar to RAL 7001) Colour: Yellow green (similar to RAL 6018) – starting from manufacturing date 5/2012 -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2. +5 °C to +70 °C for use in energy chains® with > 50.000 cycles. Minimum bending radius 10 x d. -20 °C to +70 °C, minimum bending radius 5 x d

Typical application area ● ● ● ● ●

for high load requirements light oil influence preferably indoor applications, but also outdoor ones at temperatures > 5 °C especially for freely suspended and gliding travel distances up to 100 m Storage and retrieval units for high-bay warehouses, machining units/packaging machines, handling, indoor cranes, wood/stone processing

v max. 5 m/s, 3 m/s unsupported/gliding a max. 50 m/s2

Image exemplary.

P mohase de -ou l t

Travel distance Nominal voltage

Freely suspended and gliding travel distances up to 100 m, Class 3 30 V

Testing voltage

500 V

Oil

Oil-resistant (following DIN EN 50363-4-1), Class 2.

eplan download, configurator

www.igus.eu/en/CF211M

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Three energy chain systems® in several axes fitted with specially cables from igus®. e-chain®: System E4/00 and System E4/0

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

165


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:57 Seite 166

CF211 PVC 10 x d

PVC Measuring system cable CF211

Class 5.3.2 (5 high load requirements

3 travel distance up to 100 m 2 oil-resistant)

CF211 PVC 10 x d

Image exemplary.

Delivery program Part No. CF211.001

Number of cores and conductor nominal cross section [mm2] (3x(2x0,14)C+(4x0,14)+(2x0,5))C

External diameter approx. [mm] 9,0

Copper index [kg/km] 61

Weight [kg/km]

Delivery program Part No.

Core group

Colour code

100

CF211.001

3x(2x0,14)C 4x0,14 2x0,5 3x(2x0,14)C 2x(0,5)C 3x(2x0,14)C 4x0,14 4x0,23 2x0,5 4x(2x0,25) 2x0,5 4x(2x0,25) 2x1,0 4x(2x0,34) 4x0,5 4x(2x0,25)C 2x0,5 3x(2x0,25)C (4x0,14)C 4x(2x0,14) 4x1,0 2x(2x0,25) 2x0,5 3x(2x0,25)C (3x0,25) (2x1,0)

green/yellow, black/brown, red/orange gray, blue, white-yellow, white-black brown-red, brown-blue green/yellow, black/brown, red/orange black, red green/yellow, black/brown, red/orange gray, blue, white-yellow, white-black brown-yellow, brown-gray, green-black, green-red brown-red, brown-blue brown/green, blue/violet, gray/pink, red/black white, brown brown/green, blue/violet, gray/pink, red/black white, brown black/brown, red/orange, yellow/green, blue/violet blue-white, black-white, red-white, yellow-white white/brown, green/yellow, gray/pink, blue/red black (numeral printing 1-2) white/brown, green/yellow, gray/pink blue-black, red-black, yellow-black, green-black red/black, green/brown, yellow/violet, pink/gray white-green, brown-green, blue, white red/black, gray/pink white, brown brown/green, pink/gray, red/black blue, yellow, violet white, brown

CF211.002

(3x(2x0,14)C+2x(0,5)C)C

9,0

63

110

CF211.002

CF211.006

(3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C

9,5

72

120

CF211.006

CF211.009

(4x(2x0,25)+2x0,5)C

9,0

51

111

CF211.009

CF211.010

(4x(2x0,25)+2x1,0)C

9,5

74

141

CF211.010

CF211.011

(4x(2x0,34)+4x0,5)C

9,0

75

135

CF211.011

CF211.014

(4x(2x0,25)C+1x2x0,5)C

13,0

84

211

CF211.014

CF211.016 CF211.017

(3x(2x0,25)C)C (4x(2x0,14)+4x1,0+(4x0,14)C)C

11,0 9,0

85 85

170 124

CF211.016 CF211.017

CF211.018

(2x(2x0,25)+2x0,5)C

7,0

41

62

CF211.018

CF211.019

(3x0,25+3x(2x0,25)C+2x1,0)C

9,0

82

115

CF211.019

Other types available on request. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Other types

Page 168

eplan download, configurator

950 types from stock no cutting costs ... 166

(for up to 10 cuts of the same type)

www.igus.eu/en/CF211M

... no minimum order quantity ... igus速 GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

167


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:57 Seite 168

CF211 PVC 10 x d

PVC Measuring system cable CF211

Class 5.3.2 (5 high load requirements

3 travel distance up to 100 m 2 oil-resistant)

CF211 PVC 10 x d

Image exemplary.

Delivery program Part No. New* CF211.020(1)

Number of cores and conductor nominal cross section [mm2] (3x(2x0,14)+2x(4x0,14)+(2x0,5)C)C

External diameter approx. [mm] 8,5

Copper index [kg/km] 90

Weight [kg/km]

Delivery program Part No.

103

CF211.020(1)

New* CF211.022

(5x0,5+1x2x0,25)C

7,0

50

84

CF211.022(1)

New* CF211.027

(5x(2x0,14)+2x0,5)C

9,0

45

102

CF211.027

New* CF211.028

(2x(2x0,15)+2x0,38)C

7,0

45

69

CF211.028(1)

(3x(2x0,14)+2x0,5)

8,0

44

94

CF211.038(1)

New* CF211.038(1)

(1) Delivery time upon inquiry. Other types available on request. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. x = without earth core G = with green-yellow earth core * New in this catalogue.

Core group

3x(2x0,14) 2x(4x0,14) (2x0,5) 5x0,5 2x025 5x(2x0,14) (2x0,5) (2x(2x0,15) 2x0,38 3x(2x0,14) 2x0,34

Colour code

red/blue, black/violet, gray-pink/red-blue green/gray/yellow/pink, white-green/white-yellow/brown-green/brown-yellow white/brown blue, green, yellow, gray, pink white, brown green/brown, gray/yellow, white/violet, black/red, blue/pink white-green, white-red green/yellow, pink/blue red, black white/brown, green/yellow, gray/pink blue/red

Order example: CF211.001 – in your desired length (0,5 m steps) CF211 chainflex series .001 Code Measuring system ®

Please use www.chainflex.eu/en/CF211M for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.

Other types

Page 166

eplan download, configurator

950 types from stock no cutting costs ... 168

(for up to 10 cuts of the same type)

www.igus.eu/en/CF211M

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

169


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:58 Seite 170

CF111.D PUR 12 x d

PUR Measuring system cable CF111.D ● ● ● ● ● ● ● ●

Class 4.1.3 (4 medium load requirements

for medium load requirements PUR outer jacket shielded oil-resistant and coolant-resistant Outer jacket in PUR notch-resistant flame-retardant hydrolysis-resistant and microbe-resistant PVC-free/halogen-free

NEW!

Conductor Core insulation Core stranding

Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality PP mixture.

1 freely suspended 3 oil-resistant)

CF111.D PUR 12 x d

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free UL/CSA

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Style 1589 and 21371, 30 V, 80 °C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

DESINA

According to VDW, DESINA standardisation

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1

According to measuring system specification.

Core identification

According to measuring system specification Schedule Delivery Program Element shield Extremely bending-resistant, tinned copper cover. Coverage approx. 90% optical. Intermediate jacket Foil taping over the external layer.

Typical application area Overall shield

T/R moved

Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10) – starting from manufacturing date 5/2012. Colour: Yellow green (similar to RAL 6018) -20 °C to +80 °C, minimum bending radius 12 x d

T/R fixed

-40 °C to +100 °C, minimum bending radius 6 x d

v max. freely suspended a max.

2 m/s

Travel distance

Freely suspended travel distances, Class 1

UV-resistant

Medium

Nominal voltage

30 V

Testing voltage

500 V

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3

Offshore

MUD-resistant following NEK 606 – status 2009.

Image exemplary.

Outer jacket

● ● ● ● ●

for medium load requirements almost unlimited resistance to oil indoor and outdoor applications without direct sun radiation especially for freely suspended travel distances Machining units/machine tools, low temperature applications

30 m/s2

eplan download, configurator

www.igus.eu/en/CF111D

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

The readychain® systems from igus® are completely pre-harnessed with chainflex® cables, hoses, screw attachments, metal parts etc.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

171


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:58 Seite 172

CF111.D PUR 12 x d

PUR Measuring system cable CF111.D

Class 4.1.3 (4 medium load requirements

1 freely suspended 3 oil-resistant)

CF111.D PUR 12 x d

Image exemplary.

Delivery program Part No. CF111.001.D

Number of cores and conductor nominal cross section [mm2] (3x(2x0,14)C+(4x0,14)+(2x0,5))C

CF111.004.D

(4x(2x0,14)+(4x0,14)C+4x0,5)C

10,5

72

113

CF111.004.D

CF111.006.D

(3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C

10,0

69

112

CF111.006.D

CF111.011.D

(4x(2x0,34)+4x0,5)C

9,5

69

106

CF111.011.D

CF111.015.D

(4x(2x0,14)+4x0,5)C

8,0

49

76

CF111.015.D

(3x(2x0,14)+2x(4x0,14)+(2x0,5)C)C

8,5

90

93

CF111.020.D(1)

CF111.021.D

(6x0,5+5x2x0,25)C

10,0

79

125

CF111.021.D

CF111.022.D

(5x0,5+1x2x0,25)C

8,0

49

78

CF111.022.D

CF111.027.D

(5x(2x0,14)+2x0,5)C

9,0

54

109

CF111.027.D(1)

New* CF111.028.D

(2x(2x0,15)+2x0,38))C

7,0

45

69

CF111.028.D

CF111.035.D

(4x(2x0,25)C+2x(2x0,5))C

12,5

118

202

CF111.035.D

New* CF111.020.D(1)

External diameter approx. [mm] 8,5

Copper index [kg/km] 56

Weight [kg/km]

Delivery program Part No.

Core group

Colour code

87

CF111.001.D

3x(2x0,14)C 4x0,14 2x0,5 4x(2x0,14) (4x0,14)C 4x0,5 3x(2x0,14)C 4x0,14 4x0,23 2x0,5 4x(2x0,34) 4x0,5 4x(2x0,14) 4x0,5 3x(2x0,14) 2x(4x0,14) (2x0,5) (3x0,5) (3x0,5) (5x2x0,25) (5x0,5) (2x0,25) 5x(2x0,14) (2x0,5) (2x(2x0,15) 2x0,38 4x(2x0,25)C 2x(2x0,5)

green/yellow, black/brown, red/orange gray, blue, white-yellow, white-black brown-red, brown-blue brown/green, violet/yellow, gray/pink, red/black yellow-black, red-black, green-black, blue-black brown-green, white-green, blue, white green/yellow, black/brown, red/orange gray, blue, white-yellow, white-black brown-yellow, brown-gray, green-black, green-red brown-red, brown-blue black/brown, red/orange, yellow/green, blue/violet blue-white, black-white, red-white, yellow-white brown/green, violet/yellow, gray/pink, red/black blue, white, brown-green, white-green red/blue, black/violet, gray-pink/red-blue green/gray/yellow/pink, white-green/white-yellow/brown-green/brown-yellow white/brown black (numeral printing 1-3) red (numeral printing 1-3) yellow/white, gray/white, black/orange, white/brown, black/gray blue, green, yellow, gray, pink white, brown green/brown, gray/yellow, white/violet, black/red, blue/pink white-green, white-red green/yellow, pink/blue red, black white/brown, green/yellow, gray/pink, blue/red black (numeral printing 1-4)

(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalog.

Order example: CF111.021.D – in your desired length (0,5 m steps) CF111.D chainflex series .021 Code Measuring system ®

Please use www.chainflex.eu/en/CF111D for your online order. Delivery time 24h or today. eplan download, configurator

www.igus.eu/en/CF111D

950 types from stock no cutting costs ... 172

(for up to 10 cuts of the same type)

Delivery time means time until shipping of goods.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

173


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:58 Seite 174

CF113.D PUR 10 x d

PUR Measuring system cable CF113.D ● ● ● ● ● ● ● ●

Class 6.3.3 (6 maximum load requirements

for maximum load requirements PUR outer jacket shielded oil-resistant and coolant-resistant notch-resistant flame-retardant hydrolysis-resistant and microbe-resistant PVC-free/halogen-free Conductor Core insulation Core stranding Core identification Element shield Inner jacket Overall shield

Fine-wire stranded conductor in especially bending-resistant version consisting of tinned copper wires (following EN 60228). Mechanically high-quality PP mixture.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Halogen-free

Following EN 50267-2-1.

Silicon-free UL/CSA

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Style 1589 and 20236, 30 V, 80 °C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

DESINA

According to VDW, DESINA standardisation

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1

According to measuring system specification. According to measuring system specification Schedule Delivery Program Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. TPE mixture adapted to suit the requirements in energy chains®.

T/R moved

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Yellow-green (similar to RAL 6018) -20 °C to +80 °C, minimum bending radius 10 x d

T/R fixed

-40 °C to +80 °C, minimum bending radius 5 x d

Outer jacket

3 travel distance up to 100 m 3 oil-resistant)

CF113.D PUR 10 x d

Typical application area ● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil indoor and outdoor applications without direct sun radiation especially for freely suspended and gliding travel distances up to 100 m Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, indoor cranes, low-temperature applications

v max. 5 m/s, 3 m/s unsupported/gliding a max. 50 m/s2

Image exemplary.

Travel distance UV-resistant

Freely suspended and gliding travel distances up to 100 m, Class 3 Medium

Nominal voltage

30 V

Testing voltage

500 V

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

Offshore

MUD-resistant following NEK 606 – status 2009.

eplan download, configurator

www.igus.eu/en/CF113D

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

chainflex® measuring system cable in a double-spindle horizontal machining centre.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

175


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:58 Seite 176

CF113.D PUR 10 x d

PUR Measuring system cable CF113.D

Class 6.3.3 (6 maximum load requirements

3 travel distance up to 100 m 3 oil-resistant)

CF113.D PUR 10 x d

Image exemplary.

Delivery program Part No. CF113.001.D

Number of cores and conductor nominal cross section [mm2] (3x(2x0,14)C+(4x0,14)+(2x0,5))C

CF113.002.D

(3x(2x0,14)C+2x(0,5)C)C

10,5

74

185

CF113.002.D

(3x(2x0,14)+2x1,0)C

8,5

55

124

CF113.003.D(1)

CF113.004.D

(2x(2x2x0,14)+(4x0,14)C+(4x0,5))C

11,5

82

195

CF113.004.D

CF113.005.D

(4x(2x0,14)+4x0,5)C

9,5

61

144

CF113.005.D

CF113.006.D

(3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C

11,0

84

197

CF113.006.D

CF113.007.D(2) CF113.008.D CF113.009.D

(2x2x0,34)C (3x(2x0,25))C (4x(2x0,25)+2x0,5)C

6,0 8,0 9,5

29 33 60

64 81 137

CF113.007.D CF113.008.D CF113.009.D

CF113.010.D(1)

(4x(2x0,25)+2x1,0)C

9,5

72

159

CF113.010.D(1)

CF113.011.D(1)

(4x(2x0,34)+4x0,5)C

10,5

87

199

CF113.011.D(1)

CF113.012.D(1)

(3x(2x0,14)C+(3x0,14)C+6x0,14+2x0,5)C

11,5

90

220

CF113.012.D(1)

CF113.013.D(1)

(3x(2x0,14)C+2x0,5)C

9,5

63

153

CF113.013.D(1)

CF113.014.D(1)

(4x(2x0,25)C+2x0,5)C

11,5

86

210

CF113.014.D(1)

CF113.015.D

(4x(2x0,14)+4x0,5)C

9,5

61

140

CF113.015.D

CF113.016.D

(3x(2x0,25)C)C

9,5

59

141

CF113.016.D

CF113.003.D(1)

External diameter approx. [mm] 10,5

Copper index [kg/km] 72

Weight [kg/km]

Delivery program Part No.

172

CF113.001.D

Core group

3x(2x0,14)C (4x0,14) (2x0,5) 3x(2x0,14)C 2x(0,5)C 3x(2x0,14) 2x1,0 2x(2x2x0,14) (4x0,14)C 4x0,5 4x(2x0,14) 4x0,5 3x(2x0,14)C (4x0,14) (4x0,23) (2x0,5) 4x0,34 3x(2x0,25) 4x(2x0,25) 2x0,5 4x(2x0,25) 2x1,0 4x(2x0,34) 4x0,5 3x(2x0,14)C (3x0,14)C 6x0,14 2x0,5 3x(2x0,14)C 2x0,5 4x(2x0,25)C 2x0,5 4x(2x0,14) 4x0,5 3x(2x0,25)C

Colour code

green/yellow, black/brown, red/orange gray, blue, white-yellow, white-black brown-red, brown-blue green/yellow, black/brown, red/orange black, red white/brown, green/yellow, gray/pink blue, red brown/green, violet/yellow, gray/pink, red/black yellow-black, red-black, green-black, blue-black brown-green, white-green, blue, white white/brown, green/yellow, gray/pink, blue/red black, violet, gray-pink, red-blue green/yellow, brown/black, red/orange blue, gray, white-black, white-yellow brown-yellow, brown-gray, green-black, green-red brown-red, brown-blue white, green, brown, yellow (star-quad stranding) white/brown, green/yellow, gray/pink brown/green, blue/violet, gray/pink, red/black white, brown brown/green, blue/violet, gray/pink, red/black white, brown black/brown, red/orange, yellow/green, blue/violet blue-white, black-white, red-white, yellow-white green/yellow, white/gray, blue/red red, green, brown blue, gray, gray, yellow, pink, violet brown-red, brown-blue white/brown, green/yellow, gray/pink red, blue white/brown, green/yellow, gray/pink, blue/red black (numeral printing 1-2) brown/green, violet/yellow, gray/pink, red/black blue, white, brown-green, white-green white/brown, green/yellow, gray/pink

(1) Delivery time upon inquiry. Other types available on request. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

eplan download, configurator Other types

Page 178

950 types from stock no cutting costs ... 176

www.igus.eu/en/CF113D

(for up to 10 cuts of the same type)

... no minimum order quantity ... igus速 GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

177


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:58 Seite 178

CF113.D PUR 10 x d

PUR Measuring system cable CF113.D

Class 6.3.3 (6 maximum load requirements

3 travel distance up to 100 m 3 oil-resistant)

CF113.D PUR 10 x d

Image exemplary.

Delivery program Part No. CF113.017.D(1)/(4)

Number of cores and conductor nominal cross section [mm2] (4x(2x0,14)+(4x0,14)C+4x1,0)C

CF113.018.D(1)/(4)

(2x(2x0,25)+2x0,5)C

9,0

38

114

CF113.018.D(1)/(4)

CF113.019.D(1)/(4)

(3x(2x0,25)C+(3x0,25)+2x1,0)C

11,5

96

225

CF113.019.D(1)/(4)

CF113.021.D(1)

(3x(2x0,5+2x0,25)+(4x0,25))C

11,0

92

210

CF113.021.D(1)

CF113.022.D(1)

(5x0,5+(2x0,25))C

8,5

50

121

CF113.022.D(1)

CF113.025.D(1)

(3x(2x0,14)C+(2x0,5)C)C

11,0

73

180

CF113.025.D(1)

CF113.027.D(1)

(5x(2x0,14)+2x0,5)C

9,0

52

121

CF113.027.D(1)

CF113.028.D(4)

(2x(2x0,15)+(2x0,38))C

7,5

47

72

CF113.028.D(4)

CF113.032.D(1)/(15)

3x(2x0,14)C+(3x0,14)C

8,0

61

148

CF113.032.D(1)/(15)

CF113.033.D(1)/(15)

4x(2x0,14)C+2x(1,0)C

10,0

97

237

CF113.033.D(1)/(15)

CF113.034.D(1)/(15)

3x(2x0,14)C+(4x0,14)C+2x(2x0,5)C

11,5

105

199

CF113.034.D(1)/(15)

New* CF113.037.D

(5x2x0,25)C (6x2x0,25)C

9,5 10,0

53 60

94 106

CF113.036.D CF113.037.D

New* CF113.038.D

(3x2x0,14+1x2x0,34)C

7,5

36

67

CF113.038.D

New* CF113.036.D

External diameter approx. [mm] 11,5

Copper index [kg/km] 105

Weight [kg/km]

Delivery program Part No.

Core group

Colour code

241

CF113.017.D(1)/(4)

4x(2x0,14) (4x0,14)C 4x1,0 2x(2x0,25) 2x0,5 3x(2x0,25)C (3x0,25) 2x1,0 3x(2x0,25) 3x(2x0,5) (4x0,25) 5x0,5 (2x0,25) 3x(2x0,14) (2x0,5)C 5x(2x0,14) 2x0,5 2x(2x0,15) (2x0,38) 3x(2x0,14)C (3x0,14)C 4x(2x0,14)C 2x(1,0)C 3x(2x0,14)C (4x0,14)C 2x(2x0,5)C 5x2x0,25 6x2x0,25

red/black, green/brown, yellow/violet, pink/gray blue-black, red-black, yellow-black, green-black white-green, brown-green, blue, white red/black, gray/pink white, brown brown/green, gray/pink, red/black blue, yellow, violet white, brown white/yellow, white/gray, black/orange black (numeral printing 1-6) white, gray, brown, black blue, green, yellow, gray, pink white, brown green/yellow, blue/red, gray/pink white, brown green/brown, gray/yellow, white/violet, black/red, blue/pink white-green, white-red green/yellow, pink/blue red, black yellow/black, red/black, green/black black, gray, pink yellow/black, red/black, green/black, blue/black white, brown green/black, violet/black, blue/black yellow, red-black, yellow-black, red black/brown, black/white white/brown, green/yellow, gray/pink, blue/red, black/violet white/brown, green/yellow, gray/pink, blue/red, black/violet, gray-pink/red-blue white/brown, green/yellow, gray/pink blue/red

(1) Delivery time upon inquiry. (4) manufactured without inner jacket. (15) manufactured without overall shield Other types available on request. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalogue.

Other types

3x2x0,14 1x2x0,34

Order example: CF113.027.D – in your desired length (0,5 m steps) CF113.D chainflex series .027 Code Measuring system ®

Please use www.chainflex.eu/en/CF113D for your online order.

Page 176

Delivery time 24h or today. eplan download, configurator

www.igus.eu/en/CF113D

950 types from stock no cutting costs ... 178

(for up to 10 cuts of the same type)

Delivery time means time until shipping of goods.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

179


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:58 Seite 180

CF11.D TPE 10 x d

TPE Measuring system cable CF11.D ● ● ● ● ● ● ●

Class 6.4.4 (6 maximum load requirements

for maximum load requirements TPE outer jacket shielded oil-resistant biooil-resistant PVC-free/halogen-free hydrolysis-resistant and microbe-resistant

Conductor Core insulation

Fine-wire stranded conductor in especially bending-resistant version consisting of tinned copper wires (following EN 60228). Mechanically high-quality PP mixture.

4 travel distance up to 400 m 4 oil-resistant)

CF11.D TPE 10 x d

Halogen-free

Following EN 50267-2-1.

CE

Following 2006/95/EG

DESINA

According to VDW, DESINA standardisation

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

Typical application area Core stranding Core identification Element shield Inner jacket Overall shield

According to measuring system specification. According to measuring system specification Schedule Delivery Program Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. TPE mixture adapted to suit the requirements in energy chains®.

T/R moved

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Yellow-green (similar to RAL 6018) -35 °C to +100 °C, minimum bending radius 10 x d

T/R fixed

-40 °C to +100 °C, minimum bending radius 5 x d

Outer jacket

● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil, also with bio-oils indoor and outdoor applications without direct sun radiation especially for freely suspended and gliding travel distances up to 400 m Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, indoor cranes, low-temperature applications

v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2 Travel distance UV-resistant

Freely suspended and gliding travel distances up to 400 m, Class 4 Medium

Nominal voltage

30 V

Testing voltage

500 V

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).

Image exemplary.

Silicon-free

eplan download, configurator

www.igus.eu/en/CF11D

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Pre-harnessed igus® energy supply systems for machine tool manufacture. e-chain®: System E4/4

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

181


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:58 Seite 182

CF11.D TPE 10 x d

TPE Measuring system cable CF11.D

Class 6.4.4 (6 maximum load requirements

4 travel distance up to 400 m 4 oil-resistant)

CF11.D TPE 10 x d

Image exemplary.

Delivery program Part No. CF11.001.D

Number of cores and conductor nominal cross section [mm2] (3x(2x0,14)C+(4x0,14)+(2x0,5))C

CF11.002.D

(3x(2x0,14)C+2x(0,5)C)C

10,5

74

180

CF11.002.D

CF11.003.D

(3x(2x0,14)+2x1,0)C

8,5

55

118

CF11.003.D

CF11.004.D

(2x(2x2x0,14)+(4x0,14)C+(4x0,5))C

11,5

82

188

CF11.004.D

CF11.005.D

(4x(2x0,14)+4x0,5)C

9,5

61

137

CF11.005.D

CF11.006.D(4)

(3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C

11,0

84

193

CF11.006.D(4)

CF11.007.D(2) CF11.008.D CF11.009.D

(2x2x0,34)C (3x(2x0,25))C (4x(2x0,25)+2x0,5)C

6,0 7,5 9,5

29 33 60

62 77 131

CF11.007.D CF11.008.D CF11.009.D

CF11.010.D

(4x(2x0,25)+2x1,0)C

9,5

72

153

CF11.010.D

CF11.011.D

(4x(2x0,34)+4x0,5)C

10,5

87

192

CF11.011.D

CF11.012.D

(3x(2x0,14)C+(3x0,14)C+6x0,14+2x0,5)C

11,5

90

213

CF11.012.D

CF11.013.D

(3x(2x0,14)C+2x0,5)C

9,5

63

145

CF11.013.D

CF11.014.D(1)

(4x(2x0,25)C+2x0,5)C

11,5

86

203

CF11.014.D(1)

(4x(2x0,14)+4x0,5)C

9,5

61

133

CF11.015.D

CF11.015.D

External diameter approx. [mm] 10,5

Copper index [kg/km] 72

Weight [kg/km]

Delivery program Part No.

168

CF11.001.D

Core group

3x(2x0,14)C (4x0,14) (2x0,5) 3x(2x0,14)C 2x(0,5)C 3x(2x0,14) 2x1,0 2x(2x2x0,14) (4x0,14)C 4x0,5 4x(2x0,14) 4x0,5 3x(2x0,14)C (4x0,14) (4x0,23) (2x0,5) 4x0,34 3x(2x0,25) 4x(2x0,25) 2x0,5 4x(2x0,25) 2x1,0 4x(2x0,34) 4x0,5 3x(2x0,14)C (3x0,14)C 6x0,14 2x0,5 3x(2x0,14)C 2x0,5 4x(2x0,25)C 2x0,5 4x(2x0,14) 4x0,5

Colour code

green/yellow, black/brown, red/orange gray, blue, white-yellow, white-black brown-red, brown-blue green/yellow, black/brown, red/orange black, red white/brown, green/yellow, gray/pink blue, red brown/green, violet/yellow, gray/pink, red/black yellow-black, red-black, green-black, blue-black brown-green, white-green, blue, white white/brown, green/yellow, gray/pink, blue/red black, violet, gray-pink, red-blue green/yellow, brown/black, red/orange blue, gray, white-black, white-yellow brown-yellow, brown-gray, green-black, green-red brown-red, brown-blue white, green, brown, yellow (star-quad stranding) white/brown, green/yellow, gray/pink brown/green, blue/violet, gray/pink, red/black white, brown brown/green, blue/violet, gray/pink, red/black white, brown black/brown, red/orange, yellow/green, blue/violet blue-white, black-white, red-white, yellow-white green/yellow, white/gray, blue/red red, green, brown blue, gray, gray, yellow, pink, violet brown-red, brown-blue white/brown, green/yellow, gray/pink red, blue white/brown, green/yellow, gray/pink, blue/red black (numeral printing 1-2) brown/green, violet/yellow, gray/pink, red/black blue, white, brown-green, white-green

(1) Delivery time upon inquiry. (4) manufactured without inner jacket Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Other types

Page 186

eplan download, configurator

950 types from stock no cutting costs ... 182

(for up to 10 cuts of the same type)

www.igus.eu/en/CF11D

... no minimum order quantity ... igus速 GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

183


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:58 Seite 184

CF11.D TPE 10 x d

TPE Measuring system cable CF11.D

Class 6.4.4 (6 maximum load requirements

4 travel distance up to 400 m 4 oil-resistant)

CF11.D TPE 10 x d

Image exemplary.

Delivery program Part No. CF11.016.D(1) CF11.017.D(4)

Number of cores and conductor nominal cross section [mm2] (3x(2x0,25)C)C (4x(2x0,14)+(4x0,14)C+4x1,0)C

CF11.018.D(4)

(2x(2x0,25)+2x0,5)C

7,0

36

72

CF11.018.D(4)

CF11.019.D(4)

(3x(2x0,25)C+(3x0,25)+2x1,0)C

11,5

96

218

CF11.019.D(4)

CF11.021.D

(3x(2x0,5+2x0,25)+(4x0,25))C

11,0

92

203

CF11.021.D

CF11.022.D

(5x0,5+(2x0,25))C

8,5

50

115

CF11.022.D

CF11.025.D

(3x(2x0,14)C+(2x0,5)C)C

10,5

73

174

CF11.025.D

CF11.027.D

(5x(2x0,14)+2x0,5)C

9,0

52

115

CF11.027.D

3x(2x0,14)C+(3x0,14)C

8,0

61

144

CF11.032.D(1)/(15)

CF11.033.D(15)

4x(2x0,14)C+2x(1,0)C

10,0

97

230

CF11.033.D(15)

CF11.034.D(15)

3x(2x0,14)C+(4x0,14)C+2x(2x0,5)C

11,5

105

177

CF11.034.D(15)

(3x2x0,14+1x2x0,34)C

7,5

36

67

CF11.032.D(1)/(15)

New* CF11.038.D

External diameter approx. [mm] 9,5 11,5

Copper index [kg/km] 59 105

Weight [kg/km]

Delivery program Part No.

Core group

Colour code

138 234

CF11.016.D(1) CF11.017.D(4)

3x(2x0,25)C 4x(2x0,14) (4x0,14)C 4x1,0 2x(2x0,25) 2x0,5 3x(2x0,25)C (3x0,25) 2x1,0 3x(2x0,25) 3x(2x0,5) (4x0,25) 5x0,5 (2x0,25) 3x(2x0,14) (2x0,5) 5x(2x0,14) 2x0,5 3x(2x0,14)C (3x0,14)C 4x(2x0,14)C 2x(1,0)C 3x(2x0,14)C (4x0,14)C 2x(2x0,5)C 3x2x0,14 1x2x0,34

white/brown, green/yellow, gray/pink red/black, green/brown, yellow/violet, pink/gray blue-black, red-black, yellow-black, green-black white-green, brown-green, blue, white red/black, gray/pink white, brown brown/green, gray/pink, red/black blue, yellow, violet white, brown white/yellow, white/gray, black/orange black (numeral printing 1-6) white, gray, brown, black blue, green, yellow, gray, pink white, brown green/yellow, blue/red, gray/pink white, brown green/brown, gray/yellow, white/violet, black/red, blue/pink white-green, white-red yellow/black, red/black, green/black black, gray, pink yellow/black, red/black, green/black, blue/black white, brown green/black, violet/black, blue/black yellow, red-black, yellow-black, red black/brown, black/white white/brown, green/yellow, gray/pink blue/red

CF11.038.D

(1) Delivery time upon inquiry. (4) manufactured without inner jacket (15) manufactured without overall shield Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalogue.

Order example: CF11.021.D – in your desired length (0,5 m steps) CF11.D chainflex series .021 Code Measuring system ®

Other types

Page 184

Please use www.chainflex.eu/en/CF11D for your online order. Delivery time 24h or today.

eplan download, configurator

www.igus.eu/en/CF11D

950 types from stock no cutting costs ... 184

(for up to 10 cuts of the same type)

Delivery time means time until shipping of goods.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

185


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:58 Seite 186

10

CF21.UL

PVC

7,5

-5/ +70

10

CF270.UL.D

PUR

10

-20/ +80

10

CF27.D

PUR

7,5

-20/ +80

10

Page

-5/ +70

a max. [m/s2]

10

v max. [m/s] gliding

Temperature, moved from/to [°C]

v max. [m/s] unsupported

Min. bending radius, moved [factor x d]

PVC

Oil-resistant

Shield

Approvals and standards

Jacket

CF210.UL

chainflex® cable

Servo cables

chainflex type

Torsion resistant

®

50

188

80

190

50

194

80

198

Servo cables

5

5

187


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:59 Seite 188

CF210.UL PVC 10 x d

PVC Servo cable CF210.UL ● ● ● ● ●

Class 4.1.2 (4 medium load requirements

for medium load requirements PVC outer jacket shielded oil-resistant flame-retardant

Fine-wire stranded conductor in bending-resistant version consisting of bare copper wires (following EN 60228). Core insulation Mechanically high-quality, especially low-capacitance TPE mixture. Core stranding Energy conductor with signal pair elements stranded together with elements for high tensile stresses. Core identification Energy conductor: Cores black with white numerals, one core green-yellow. 1. core: U / L1 / C / L+ 2. core: V / L2 3. core: W / L3 / D / L1 signal pair: Cores black with white numerals. 1. control core: 4 2. control core: 5 2 signal pairs: Cores black with white numerals. 1. control core: 5 2. control core: 6 3. control core: 7 4. control core: 8 Star-quad: yellow, black, red, white Element shield Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical. Intermediate jacket Foil taping over the external layer.

Nominal voltage

600/1000 V (following DIN VDE 0250).

Testing voltage

4000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 50363-4-1), Class 2.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1

Silicon-free UL

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Style 10989 and 2570, 1000 V, 80 °C

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1.

Conductor

Overall shield Outer jacket

T/R moved

Image exemplary.

T/R fixed

Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in energy chains® (following DIN VDE 0281 Part 13). Colour: Pastellorange (similar to RAL 2003) -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2. +5 °C to +70 °C for use in energy chains® with > 50.000 cycles. Minimum bending radius 10 x d. -20 °C to +70 °C, minimum bending radius 5 x d

v max. freely suspended a max.

10 m/s 50 m/s2

Travel distance

Freely suspended travel distances, Class 1

UV-resistant

Medium

eplan download, configurator

1 freely suspended 2 oil-resistant)

CF210.UL PVC 10 x d

Typical application area ● ● ● ● ●

for medium load requirements light oil influence preferably indoor applications, but also outdoor ones at temperatures > 5 °C especially for freely suspended travel distances Wood/stone processing, packaging industry, supply system, handling, adjusting equipment

Delivery program Part No. 1 signal pair shielded CF210.UL.15.15.02.01 CF210.UL.25.15.02.01 CF210.UL.40.15.02.01 CF210.UL.60.15.02.01(1) 2 signal pairs shielded CF210.UL.15.07.02.02 CF210.UL.25.15.02.02 CF210.UL.40.15.02.02 CF210.UL.60.15.02.02(1)

Number of cores and conductor nominal cross section [mm2] (4 G 1,5+(2x1,5)C)C (4 G 2,5+(2x1,5)C)C (4 G 4,0+(2x1,5)C)C (4 G 6,0+(2x1,5)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 4,0+2x(2x1,5)C)C (4 G 6,0+2x(2x1,5)C)C

External diameter approx. [mm]

Copper index [kg/km]

Weight [kg/km]

12,0 13,5 15,0 16,5

149 203 272 364

250 320 412 521

13,5 15,5 17,0 18,5

169 260 330 425

290 408 506 633

(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

www.igus.eu/en/CF210UL

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

189


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:59 Seite 190

CF21.UL PVC 7,5 x d

PVC Servo cable CF21.UL ● ● ● ● ●

Class 5.3.2 (5 high load requirements

for high load requirements PVC outer jacket shielded oil-resistant flame-retardant

Conductor Core insulation Core stranding Core identification

Element shield Inner jacket Overall shield Outer jacket

T/R moved

T/R fixed

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality, especially low-capacitance TPE mixture. Energy conductor with signal pair elements stranded together with elements for high tensile stresses. Energy conductor: Cores black with white numerals, one core green-yellow. 1. core: U / L1 / C / L+ 2. core: V / L2 3. core: W / L3 / D / L1 signal pair: Cores black with white numerals. 1. control core: 4 2. control core: 5 2 signal pairs: Cores black with white numerals. 1. control core: 5 2. control core: 6 3. control core: 7 4. control core: 8 Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. PVC mixture adapted to suit the requirements in energy chains®. Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in energy chains® (following DIN VDE 0281 Part 13). Colour: Moss green (similar to RAL 6005) -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2. +5 °C to +70 °C for use in energy chains® with > 50.000 cycles. Minimum bending radius 7,5 x d. -20 °C to +70 °C, minimum bending radius 4 x d

3 travel distance up to 100 m 2 oil-resistant)

CF21.UL PVC 7,5 x d

Nominal voltage

600/1000 V (following DIN VDE 0250).

Testing voltage

4000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 50363-4-1), Class 2.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free UL/CSA

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Style 10492 and 2570, 1000 V, 80 °C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1.

Typical application area ● ● ● ● ●

for high load requirements light oil influence preferably indoor applications, but also outdoor ones at temperatures > 5 °C especially for freely suspended and gliding travel distances up to 100 m Storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling, indoor cranes

v max. 10 m/s, 5 m/s unsupported/gliding a max. 80 m/s2 Travel distance UV-resistant

Freely suspended and gliding travel distances up to 100 m, Class 3 Medium

Image exemplary.

chainflex® CF21.UL: cables for energy supply systems in spinneret production. e-chain®: Serie E2/000

eplan download, configurator

www.igus.eu/en/CF21UL

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Test data

Page 50 or www.igus.eu/en/test12

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

191


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:59 Seite 192

CF21.UL PVC 7,5 x d

PVC Servo cable CF21.UL

Class 5.3.2 (5 high load requirements

3 travel distance up to 100 m 2 oil-resistant)

CF21.UL PVC 7,5 x d

Image exemplary.

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] (4 G 0,75+(2x0,5)C)C (4 G 1,5+(2x1,5)C)C (4 G 2,5+(2x1,5)C)C (4 G 4,0+(2x1,5)C)C (4 G 6,0+(2x1,5)C)C (4 G 10+(2x1,5)C)C (4 G 16+(2x1,5)C)C (4 G 25+(2x1,5)C)C (4 G 35+(2x1,5)C)C

1 signal pair shielded CF21.07.05.02.01.UL CF21.15.15.02.01.UL CF21.25.15.02.01.UL CF21.40.15.02.01.UL CF21.60.15.02.01.UL CF21.100.15.02.01.UL CF21.160.15.02.01.UL(1) CF21.250.15.02.01.UL(1) CF21.350.15.02.01.UL(1) 2 signal pairs shielded CF21.07.03.02.02.UL (4 G 0,75+2x(2x0,34)C)C CF21.10.07.02.02.UL (4 G 1,0+2x(2x0,75)C)C CF21.15.07.02.02.UL (4 G 1,5+2x(2x0,75)C)C CF21.25.15.02.02.UL (4 G 2,5+2x(2x1,5)C)C CF21.40.15.02.02.UL (4 G 4,0+2x(2x1,5)C)C CF21.60.15.02.02.UL (4 G 6,0+2x(2x1,5)C)C CF21.100.15.02.02.UL (4 G 10+2x(2x1,5)C)C CF21.160.15.02.02.UL (4 G 16+2x(2x1,5)C)C CF21.250.15.02.02.UL (4 G 25+2x(2x1,5)C)C CF21.350.15.02.02.UL (4 G 35+2x(2x1,5)C)C

External diameter approx. [mm]

Copper index [kg/km]

Weight [kg/km]

11,5 13,0 14,0 15,5 18,0 22,5 24,5 29,5 33,0

95 144 197 256 357 540 716 1056 1557

185 280 312 412 605 925 1165 1466 2090

12,5 13,5 14,5 17,0 18,5 21,0 24,0 27,0 31,0 34,0

113 146 175 265 313 409 594 790 1140 1597

217 277 324 450 527 712 1025 1270 1910 2175

Order example: CF21.15.15.02.01.UL – in your desired length (0,5 m steps) CF21.UL chainflex series .15 Code nominal cross section .15 Code nominal cross section signalpairs .02 Identification pairs .01 Number of pairs ®

Please use www.chainflex.eu/en/CF21UL for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.

(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

eplan download, configurator

www.igus.eu/en/CF21UL

950 types from stock no cutting costs ... 192

(for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

193


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:59 Seite 194

CF270.UL.D PUR 10 x d

PUR Servo cable CF270.UL.D ● ● ● ● ● ● ● ●

Class 4.1.3 (4 medium load requirements

for medium load requirements PUR outer jacket shielded oil-resistant and coolant-resistant notch-resistant flame-retardant hydrolysis-resistant and microbe-resistant PVC-free/halogen-free Fine-wire stranded conductor in bending-resistant version consisting of bare copper wires (following EN 60228) Core insulation Mechanically high-quality, especially low-capacitance TPE mixture. Core stranding Energy conductor with signal pair elements stranded together with elements for high tensile stresses. Core identification Energy conductor: Cores black with white numerals, one core green-yellow. 1. core: U / L1 / C / L+ 2. core: V / L2 3. core: W / L3 / D / L1 signal pair: Cores black with white numerals. 1. control core: 4 2. control core: 5 2 signal pairs: Cores black with white numerals. 1. control core: 5 2. control core: 6 3. control core: 7 4. control core: 8 1 Control triple: Cores black with white numerals. 1. control core: 1 2. control core: 2 3. control core: 3 Star-quad: yellow, black, red, white Element shield Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical. Intermediate jacket Foil taping over the external layer.

1 freely suspended 3 oil-resistant)

CF270.UL.D PUR 10 x d

UV-resistant

Medium

Nominal voltage

600/1000 V (following DIN VDE 0250).

Testing voltage

4000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

Offshore

MUD-resistant following NEK 606 – status 2009.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free Halogen-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

UL/CSA

Style 10989 and 21223, 1000 V, 80 °C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

DESINA

According to VDW, DESINA standardisation

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1

Conductor

Overall shield

T/R moved

Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical. Low-adhesion mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Pastel orange (similar to RAL 2003) -20 °C to +80 °C, minimum bending radius 10 x d

T/R fixed

-40 °C to +80 °C, minimum bending radius 5 x d

v max. freely suspended a max.

10 m/s 50 m/s2

Travel distance

Freely suspended travel distances, Class 1

Image exemplary.

Outer jacket

eplan download, configurator

Typical application area ● ● ● ● ●

for medium load requirements almost unlimited resistance to oil indoor and outdoor applications without direct sun radiation especially for freely suspended travel distances Machining units/machine tools, low temperature applications

www.igus.eu/en/CF270ULD

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

195


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:59 Seite 196

CF270.UL.D PUR 10 x d

PUR Servo cable CF270.UL.D

Class 4.1.3 (4 medium load requirements

1 freely suspended 3 oil-resistant)

CF270.UL.D PUR 10 x d

Image exemplary.

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] (4 G 1,5+(2x1,5)C)C (4 G 2,5+(2x1,5)C)C (4 G 4,0+(2x1,5)C)C (4 G 6,0+(2x1,5)C)C (4 G 10,0+(2x1,5)C)C (4 G 16,0+(2x1,5)C)C

1 signal pair shielded CF270.UL.15.15.02.01.D CF270.UL.25.15.02.01.D CF270.UL.40.15.02.01.D CF270.UL.60.15.02.01.D CF270.UL.100.15.02.01.D CF270.UL.160.15.02.01.D 2 signal pairs shielded CF270.UL.07.03.02.02.D (4 G 0,75+2x(2x0,34)C)C CF270.UL.10.07.02.02.D (4 G 1,0+2x(2x0,75)C)C CF270.UL.15.07.02.02.D (4 G 1,5+2x(2x0,75)C)C CF270.UL.25.15.02.02.D (4 G 2,5+2x(2x1,5)C)C CF270.UL.40.15.02.02.D (4 G 4,0+2x(2x1,5)C)C CF270.UL.60.15.02.02.D(1) (4 G 6,0+2x(2x1,5)C)C CF270.UL.100.15.02.02.D (4 G 10,0+2x(2x1,5)C)C CF270.UL.160.15.02.02.D(1) (4 G 16,0+2x(2x1,5)C)C CF270.UL.250.15.02.02.D (4 G 25,0+2x(2x1,5)C)C CF270.UL.350.15.02.02.D(1) (4 G 35,0+2x(2x1,5)C)C 1 Control triple CF270.UL.15.10.03.01.D(9) (4 G 1,5+(3x1,0)C)C (10) CF270.UL.25.10.03.01.D (4 G 2,5+(3x1,0)C)C 1 Star-quad shielded CF270.UL.60.05.04.D (4 G 6,0+(4x0,5)C)C Without signal pair CF270.UL.15.04.D (4 G 1,5)C CF270.UL.25.04.D (4 G 2,5)C CF270.UL.40.04.D (4 G 4,0)C CF270.UL.60.04.D (4 G 6,0)C CF270.UL.100.04.D (4 G 10,0)C CF270.UL.160.04.D (4 G 16,0)C CF270.UL.250.04.D (4 G 25,0)C CF270.UL.350.04.D (4 G 35,0)C

External diameter approx. [mm]

Copper index [kg/km]

Weight [kg/km]

12,0 13,5 15,0 16,5 20,5 24,0

149 203 272 364 582 855

246 317 408 521 841 1225

11,5 13,0 13,5 15,5 17,0 18,5 22,0 26,0 28,0 35,0

107 143 169 260 330 425 632 901 1365 1804

197 251 290 408 506 633 940 1315 1847 2516

14,0 14,0

160 203

288 327

16,5

350

512

9,0 11,0 12,5 14,5 18,0 21,5 25,5 33,0

82 141 211 306 496 782 1197 1695

147 224 309 434 698 1052 1572 2312

Order example: CF270.UL.25.15.02.01.D – in your desired length (0,5 m steps) CF270.UL.D chainflex series .25 Code nominal cross section .15 Code nominal cross section signalpairs .02 Identification pairs .01 Number of pairs ®

Please use www.chainflex.eu/en/CF270ULD for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.

(1) Delivery time upon inquiry. (9) core/core: 50 pF/m, core/Shield: 95 pF/m (10) core/core: 70 pF/m, core/Shield: 115 pF/m Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

eplan download, configurator

950 types from stock no cutting costs ... 196

(for up to 10 cuts of the same type)

www.igus.eu/en/CF270ULD

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

197


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:59 Seite 198

CF27.D PUR 7,5 x d

PUR Servo cable CF27.D ● ● ● ● ● ● ● ●

Class 6.3.3 (6 maximum load requirements

for maximum load requirements PUR outer jacket shielded oil-resistant and coolant-resistant notch-resistant flame-retardant hydrolysis-resistant and microbe-resistant PVC-free/halogen-free Conductor Core insulation Core identification

Core stranding Element shield Inner jacket

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality, especially low-capacitance TPE mixture. Energy conductor: Cores black with white numerals, one core green-yellow. 1. core: U / L1 / C / L+ 2. core: V / L2 3. core: W / L3 / D / L1 signal pair: Cores black with white numerals. 1. control core: 4 2. control core: 5 2 signal pairs: Cores black with white numerals. 1. control core: 5 2. control core: 6 3. control core: 7 4. control core: 8 Star-quad: yellow, black, red, white Energy conductor with signal pair elements stranded together with elements for high tensile stresses. Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. PUR mixture adapted to suit the requirements in energy chains®.

3 travel distance up to 100 m 3 oil-resistant)

CF27.D PUR 7,5 x d

Testing voltage

4000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

Offshore

MUD-resistant following NEK 606 – status 2009.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free Halogen-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

UL/CSA

Style 10492 and 20234, 1000 V, 80 °C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

DESINA

According to VDW, DESINA standardisation

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1

Typical application area Overall shield

T/R moved

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Pastel orange (similar to RAL 2003) -20 °C to +80 °C, minimum bending radius 7,5 x d

T/R fixed

-40 °C to +80 °C, minimum bending radius 4 x d

Outer jacket

● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 100 m Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, outdoor cranes, low-temperature applications

v max. 10 m/s, 5 m/s unsupported/gliding a max. 80 m/s2 Travel distance UV-resistant

Freely suspended and gliding travel distances up to 100 m, Class 3 Medium

Nominal voltage

600/1000 V (following DIN VDE 0250).

Image exemplary.

Modular design, easy to retrofit: igus® E4 energy supply system and chainflex® cables.

eplan download, configurator

www.igus.eu/en/CF27D

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Test data

Page 30 or www.igus.eu/en/test1

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

199


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:59 Seite 200

CF27.D PUR 7,5 x d

PUR Servo cable CF27.D

Class 6.3.3 (6 maximum load requirements

3 travel distance up to 100 m 3 oil-resistant)

CF27.D PUR 7,5 x d

Image exemplary.

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] (4 G 0,75+(2x0,5)C)C (4 G 1,5+(2x1,0)C)C (4 G 1,5+(2x1,5)C)C (4 G 2,5+(2x1,0)C)C (4 G 2,5+(2x1,5)C)C (4 G 4,0+(2x1,5)C)C (4 G 6,0+(2x1,5)C)C (4 G 10,0+(2x1,5)C)C (4 G 16,0+(2x1,5)C)C (4 G 25,0+(2x1,5)C)C (4 G 35,0+(2x1,5)C)C

1 signal pair shielded CF27.07.05.02.01.D CF27.15.10.02.01.D(11) CF27.15.15.02.01.D CF27.25.10.02.01.D(11) CF27.25.15.02.01.D CF27.40.15.02.01.D CF27.60.15.02.01.D CF27.100.15.02.01.D CF27.160.15.02.01.D CF27.250.15.02.01.D CF27.350.15.02.01.D 2 signal pairs shielded CF27.07.03.02.02.D (4 G 0,75+2x(2x0,34)C)C CF27.10.07.02.02.D (4 G 1,0+2x(2x0,75)C)C CF27.15.07.02.02.D (4 G 1,5+2x(2x0,75)C)C CF27.25.15.02.02.D (4 G 2,5+2x(2x1,5)C)C CF27.40.15.02.02.D (4 G 4,0+2x(2x1,5)C)C CF27.60.15.02.02.D (4 G 6,0+2x(2x1,5)C)C CF27.100.15.02.02.D (4 G 10,0+2x(2x1,5)C)C CF27.160.15.02.02.D (4 G 16,0+2x(2x1,5)C)C CF27.250.15.02.02.D (4 G 25,0+2x(2x1,5)C)C (1) CF27.350.15.02.02.D (4 G 35,0+2x(2x1,5)C)C 1 Star-quad shielded CF27.15.05.04.D (4 G 1,5+(4x0,5)C)C CF27.25.05.04.D (4 G 2,5+(4x0,5)C)C CF27.40.05.04.D (4 G 4,0+(4x0,5)C)C CF27.60.05.04.D (4 G 6,0+(4x0,5)C)C

External diameter approx. [mm]

Copper index [kg/km]

Weight [kg/km]

11,5 12,5 13,0 14,0 14,5 16,0 17,5 21,5 24,5 28,5 32,5

95 130 144 184 199 257 357 540 716 1140 1560

175 226 260 297 325 402 580 900 1150 1523 2079

12,5 13,5 14,0 16,5 18,0 20,0 23,5 26,0 31,0 33,5

105 152 175 265 314 410 594 790 1200 1597

206 265 300 412 485 643 1000 1250 1890 2150

13,0 14,5 16,0 17,5

142 199 256 371

310 348 480 550

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] (4 G 0,75)C (4 G 1,0)C (4 G 1,5)C (4 G 2,5)C (4 G 50,0)C

Without signal pair CF27.07.04.D(1) CF27.10.04.D(1) CF27.15.04.D CF27.25.04.D CF27.500.04.D

External diameter approx. [mm] 9,5 10,0 10,5 12,5 37,0

Copper index [kg/km]

Weight [kg/km]

52 62 86 140 2230

113 126 163 260 3200

(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. x = without earth core G = with green-yellow earth core

Order example: CF27.15.10.02.01.D – in your desired length (0,5 m steps) CF27 chainflex series .15 Code nominal cross section .10 Code nominal cross section signalpairs .02 Identification pairs .01 Number of pairs ®

Please use www.chainflex.eu/en/CF27D for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.

(1) Delivery time upon inquiry. (11) Phase-out model Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

eplan download, configurator

www.igus.eu/en/CF27D

950 types from stock no cutting costs ... 200

(for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

201


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:00 Seite 202

®

Torsion resistant

v max. [m/s] unsupported

v max. [m/s] gliding

a max. [m/s2]

Page

80

204

10

5

80

206

10

6

80

208

10

6

80

210

10

6

80

212

10

6

80

214

10

6

100

216

10

6

100

218

10

6

100

220

10

6

100

222

10

6

100

224

10

6

50

226

-5/ +70

7,5

-5/ +70

7,5

-35/ +90

7,5

-35/ +90

7,5

-35/ +90

7,5

-35/ +90

TPE

7,5

-35/ +90

CFPE

TPE

7,5

-35/ +90

CF310.UL

TPE

7,5

-35/ +90

CF330.D

TPE

7,5

-35/ +90

CF340

TPE

7,5

-35/ +90

iguprene ✔

10

-20/ +80

Jacket

Shield

Oil-resistant

Approvals and standards

5

Temperature, moved from/to [°C]

10

Min. bending radius, moved [factor x d]

7,5

chainflex® cable

Power cables

chainflex type Power cables CF30

PVC

CF31

PVC

CF34.UL.D

TPE

CF35.UL

TPE

CF37.D

TPE

CF38

TPE

CF300.UL.D

CF CRANE

Power cables (Chapter "Special cables"

254)

CF FLAT

TPE

5

-35/ +90

10

6

100

260

CF BRAID

TPE

7,5

-35/ +70

10

6

80

262

CF BRAID.C

TPE

7,5

-35/ +70

10

6

80

262

Pneumatic hoses CF AIR

PU

10

-25/ +80

10

6

50

228

CF Clean AIR

PE

10

-25/ +60

10

6

50

230

203


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:00 Seite 204

CF30 PVC 7,5 x d

PVC Power cable CF30 ● ● ● ●

Class 5.3.2 (5 high load requirements

for high load requirements PVC outer jacket oil-resistant flame-retardant

Conductor

Core insulation Core stranding Core identification

Outer jacket

T/R moved

T/R fixed

Silicon-free

< 10 mm : Fine-wire stranded conductor in especially bendingresistant version consisting of bare copper wires (following EN 60228). ≥ 10 mm2: conductor cable consisting of pre-leads (following EN 60228). Mechanically high-quality, especially low-capacitance TPE mixture. Cores stranded in short pitch lengths over a centre for high tensile stresses. Energy conductor: Cores black with white numerals, one core green-yellow. 1. core: U / L1 / C / L+ 2. core: V / L2 3. core: W / L3 / D / L4. core: 4 / N Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in energy chains® (following DIN VDE 0281 Part 13). Colour: Jet black (similar to RAL 9005) -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2. +5 °C to +70 °C for use in energy chains® with > 50.000 cycles. Minimum bending radius 7,5 x d. -20 °C to +70 °C, minimum bending radius 4 x d

UL/CSA

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Style 10492 and 2570, 1000 V, 80 °C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1.

2

v max. 10 m/s, 5 m/s unsupported/gliding a max. 80 m/s2 Travel distance

3 travel distance up to 100 m 2 oil-resistant)

CF30 PVC 7,5 x d

Torsion

Freely suspended and gliding travel distances up to 100 m, Class 3 ± 90 °, with 1 m cable length

UV-resistant

Medium

Nominal voltage

600/1000 V (following DIN VDE 0250).

Testing voltage

4000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 50363-4-1), Class 2.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Typical application area ● ● ● ● ●

for high load requirements light oil influence preferably indoor applications, but also outdoor ones at temperatures > 5 °C especially for freely suspended and gliding travel distances up to 100 m Storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling, indoor cranes

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] 4 G 1,5 4 G 2,5 5 G 2,5 4 G 4,0 5 G 4,0 4 G 6,0 5 G 6,0 4 G 10,0 5 G 10,0 4 G 16,0 5 G 16,0 4 G 25,0 4 G 35,0 4 G 50,0

CF30.15.04 CF30.25.04 CF30.25.05 CF30.40.04 CF30.40.05 CF30.60.04 CF30.60.05 CF30.100.04 CF30.100.05 CF30.160.04 CF30.160.05 CF30.250.04 CF30.350.04 CF30.500.04

External diameter approx. [mm] 8,5 10,5 11,5 12,0 13,0 14,0 15,0 18,0 20,0 21,0 24,0 26,0 29,0 35,0

Copper index [kg/km] 58 96 125 158 198 239 290 411 517 639 800 1020 1420 1990

Weight [kg/km] 105 165 199 242 295 351 417 581 731 904 1132 1425 1810 2675

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF30.15.04 – in your desired length (0,5 m steps) CF30 chainflex series .15 Code nominal cross section .04 Number of cores ®

Please use www.chainflex.eu/en/CF30 for your online order.

Image exemplary.

Delivery time 24h or today. eplan download, configurator

www.igus.eu/en/CF30

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Delivery time means time until shipping of goods.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

205


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:00 Seite 206

CF31 PVC 7,5 x d

PVC Power cable CF31 ● ● ● ● ●

Class 5.3.2 (5 high load requirements

for high load requirements PVC outer jacket shielded oil-resistant flame-retardant

Conductor

Core insulation Core stranding Core identification

Inner jacket Overall shield Outer jacket

T/R moved

T/R fixed

Silicon-free

< 10 mm : Fine-wire stranded conductor in especially bendingresistant version consisting of bare copper wires (following EN 60228). ≥ 10 mm2: conductor cable consisting of pre-leads (following EN 60228). Mechanically high-quality, especially low-capacitance TPE mixture. Cores stranded in short pitch lengths over a centre for high tensile stresses. Energy conductor: Cores black with white numerals, one core green-yellow. 1. core: U / L1 / C / L+ 2. core: V / L2 3. core: W / L3 / D / L4. core: 4 / N PVC mixture adapted to suit the requirements in energy chains®.

UL/CSA

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Style 10492 and 2570, 1000 V, 80 °C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1.

2

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in energy chains® (following DIN VDE 0281 Part 13). Colour: Jet black (similar to RAL 9005) -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2. +5 °C to +70 °C for use in energy chains® with > 50.000 cycles. Minimum bending radius 7,5 x d. -20 °C to +70 °C, minimum bending radius 4 x d

v max. 10 m/s, 5 m/s unsupported/gliding a max. 80 m/s2 Travel distance

3 travel distance up to 100 m 2 oil-resistant)

CF31 PVC 7,5 x d

UV-resistant

Freely suspended and gliding travel distances up to 100 m, Class 3 Medium

Nominal voltage

600/1000 V (following DIN VDE 0250).

Testing voltage

4000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 50363-4-1), Class 2.

Typical application area ● ● ● ● ●

for high load requirements light oil influence preferably indoor applications, but also outdoor ones at temperatures > 5 °C especially for freely suspended and gliding travel distances up to 100 m Storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling, indoor cranes

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] (4 G 1,5)C (4 G 2,5)C (5 G 2,5)C (4 G 4,0)C (5 G 4,0)C (4 G 6,0)C (5 G 6,0)C (4 G 10,0)C (5 G 10,0)C (4 G 16,0)C (4 G 25,0)C (4 G 35,0)C (4 G 50,0)C (4 G 70,0)C

CF31.15.04 CF31.25.04 CF31.25.05 CF31.40.04 CF31.40.05 CF31.60.04 CF31.60.05 CF31.100.04 CF31.100.05 CF31.160.04 CF31.250.04 CF31.350.04 CF31.500.04 CF31.700.04(5)

External diameter approx. [mm] 10,5 12,0 13,0 13,5 15,0 16,0 18,0 21,0 23,0 24,0 28,5 32,5 38,5 46,5

Copper index [kg/km] 85 129 158 197 253 299 362 501 624 748 1160 1570 2180 3140

Weight [kg/km] 171 237 280 326 397 475 577 772 934 1090 1643 2155 3125 4367

(5) Cable with PVC core insulation, UL-Style 10579 and 2570 , 600 V, 80° Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF31.25.04 – in your desired length (0,5 m steps) CF31 chainflex series .25 Code nominal cross section .04 Number of cores ®

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Please use www.chainflex.eu/en/CF31 for your online order.

Image exemplary.

Delivery time 24h or today. eplan download, configurator

www.igus.eu/en/CF31

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Delivery time means time until shipping of goods.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

207


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:00 Seite 208

CF34.UL.D TPE 7,5 x d

TPE Power cable CF34.UL.D ● ● ● ● ● ● ●

for maximum load requirements TPE outer jacket oil-resistant biooil-resistant flame-retardant UV-resistant hydrolysis-resistant and microbe-resistant

Conductor

Core insulation Core stranding Core identification

Outer jacket

T/R moved T/R fixed

< 10 mm : Fine-wire stranded conductor in especially bendingresistant version consisting of bare copper wires (following EN 60228). ≥ 10 mm2: conductor cable consisting of pre-leads (following EN 60228). Mechanically high-quality, especially low-capacitance TPE mixture. Cores stranded in short pitch lengths over a centre for high tensile stresses. Energy conductor: Cores black with white numerals, one core green-yellow. 1. core: U / L1 / C / L+ 2. core: V / L2 3. core: W / L3 / D / L4. core: 4 / N Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Jet black (similar to RAL 9005) -35 °C to +90 °C, minimum bending radius 7,5 x d

Travel distance

-40 °C to +90 °C, minimum bending radius 4 x d

Torsion

Freely suspended and gliding travel distances up to 400 m and more, Class 4 ± 90 °, with 1 m cable length

UV-resistant

High

Nominal voltage

600/1000 V (following DIN VDE 0250).

Testing voltage

4000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Flame-retardant Silicon-free

UL/CSA

Style 10492 and 21184, 1000 V, 80 °C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

DESINA

According to VDW, DESINA standardisation

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1, material/cable tested by IPA according to ISO standard 14644-1

2

v max. 10 m/s, 6 m/s unsupported/gliding a max. 80 m/s2

Image exemplary.

Class 6.4.4

CF34.UL.D TPE (6 maximum load requirements 4 travel distance up to 400 m and more 4 oil-resistant) 7,5 x d

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).

eplan download, configurator

www.igus.eu/en/CF34

Typical application area ● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m and more Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

Delivery program Part No. CF34.UL.15.04.D CF34.UL.25.04.D CF34.UL.40.04.D CF34.UL.60.04.D CF34.UL.60.05.D CF34.UL.100.04.D CF34.UL.100.05.D CF34.UL.160.04.D CF34.UL.160.05.D CF34.UL.250.04.D

Number of cores and conductor nominal cross section [mm2] 4 G 1,5 4 G 2,5 4 G 4,0 4 G 6,0 5 G 6,0 4 G 10,0 5 G 10,0 4 G 16,0 5 G 16,0 4 G 25,0

CF34.UL.60.04.O.PE.D(1) CF34.UL.100.04.O.PE.D CF34.UL.160.04.O.PE.D CF34.UL.500.03.O.PE.D

4 x 6,0 4 x 10,0 4 x 16,0 3 x 50,0

External diameter approx. [mm] 8,5 10,5 12,0 14,0 15,5 17,0 19,5 20,5 23,0 25,0 14,0 17,0 20,5 31,0

Copper index [kg/km] 58 96 158 239 285 411 517 633 800 994

Weight [kg/km]

239 411 633 1490

351 549 817 2028

109 162 239 351 420 549 687 817 1072 1266

Other types available on request. (1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF34.UL.160.04.D – in your desired length (0,5 m steps) CF34.UL.D chainflex series .160 Code nominal cross section .04 Number of cores ®

Please use www.chainflex.eu/en/CF34 for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

209


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:00 Seite 210

CF35.UL TPE 7,5 x d

TPE Power cable CF35.UL ● ● ● ● ● ● ●

Class 6.4.4 (6 maximum load requirements

for maximum load requirements TPE outer jacket shielded oil-resistant, biooil-resistant flame-retardant UV-resistant hydrolysis-resistant and microbe-resistant

Conductor

Core insulation Core stranding Core identification

Inner jacket Overall shield

< 10 mm : Fine-wire stranded conductor in especially bendingresistant version consisting of bare copper wires (following EN 60228). ≥ 10 mm2: conductor cable consisting of pre-leads (following EN 60228). Mechanically high-quality, especially low-capacitance TPE mixture. Cores stranded in short pitch lengths over a centre for high tensile stresses. Energy conductor: Cores black with white numerals, one core green-yellow. 1. core: U / L1 / C / L+ 2. core: V / L2 3. core: W / L3 / D / L4. core: 4 / N TPE mixture adapted to suit the requirements in energy chains®.

T/R moved T/R fixed

-40 °C to +90 °C, minimum bending radius 4 x d

v max. 10 m/s, 6 m/s unsupported/gliding a max. 80 m/s2 Travel distance

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free UL/CSA

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Style 10492 and 21184, 1000 V, 80 °C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, tested by IPA according to standard 14644-1

2

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Jet black (similar to RAL 9005) -35 °C to +90 °C, minimum bending radius 7,5 x d

Outer jacket

4 travel distance up to 400 m and more 4 oil-resistant)

CF35.UL TPE 7,5 x d

UV-resistant

Freely suspended and gliding travel distances up to 400 m and more, Class 4 High

Nominal voltage

600/1000 V (following DIN VDE 0250).

Testing voltage

4000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4.

Typical application area ● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m and more Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

Delivery program Part No. CF35.UL.05.04 CF35.UL.07.04 CF35.UL.15.04 CF35.UL.25.04 CF35.UL.40.04 CF35.UL.60.04 CF35.UL.100.04 CF35.UL.160.04 CF35.UL.250.04 CF35.UL.60.03.O.PE(1) CF35.UL.100.03.O.PE(1) CF35.UL.160.03.O.PE CF35.UL.250.03.O.PE(1) CF35.UL.350.03.O.PE CF35.UL.500.03.O.PE

Number of cores and conductor nominal cross section [mm2] (4 G 0,5)C (4 G 0,75)C (4 G 1,5)C (4 G 2,5)C (4 G 4,0)C (4 G 6,0)C (4 G 10,0)C (4 G 16,0)C (4 G 25,0)C (3 x 6,0)C (3 x 10,0)C (3 x 16,0)C (3 x 25,0)C (3 x 35,0)C (3 x 50,0)C

External diameter approx. [mm] 8,0 8,5 9,5 11,5 13,5 16,0 19,5 23,0 27,5 14,5 17,5 21,0 24,5 28,5 33,5

Copper index [kg/km] 39 52 85 128 201 298 454 723 1160

Weight [kg/km]

231 356 553 884 1200 1660

367 568 789 1208 1675 2283

81 104 149 207 326 450 682 1003 1524

Image exemplary.

(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

eplan download, configurator

www.igus.eu/en/CF35

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

211


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:00 Seite 212

CF37.D TPE 7,5 x d

TPE Power cable CF37.D ● ● ● ● ● ●

Class 7.4.4 (7 maximum load requirements

for maximum load requirements TPE outer jacket oil-resistant, biooil-resistant PVC-free/halogen-free UV-resistant hydrolysis-resistant and microbe-resistant

Conductor

T/R moved

< 10 mm2: Fine-wire stranded conductor in especially bendingresistant version consisting of bare copper wires (following EN 60228). ≥ 10 mm2: conductor cable consisting of pre-leads (following EN 60228). Mechanically high-quality, especially low-capacitance TPE mixture. Cores stranded in short pitch lengths over a centre for high tensile stresses. Energy conductor: Cores black with white numerals, one core green-yellow. 1. core: U / L1 / C / L+ 2. core: V / L2 3. core: W / L3 / D / L4. core: 4 / N Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Jet black (similar to RAL 9005) -35 °C to +90 °C, minimum bending radius 7,5 x d

T/R fixed

-40 °C to +90 °C, minimum bending radius 4 x d

Core insulation Core stranding Core identification

Outer jacket

v max. 10 m/s, 6 m/s unsupported/gliding a max. 80 m/s2 Travel distance Torsion

Freely suspended and gliding travel distances up to 400 m and more, Class 4 ± 90 °, with 1 m cable length

UV-resistant

High

Nominal voltage

600/1000 V (following DIN VDE 0250).

Testing voltage

4000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

Silicon-free Halogen-free

4 travel distance up to 400 m and more 4 oil-resistant)

CF37.D TPE 7,5 x d

CE

Following 2006/95/EG

DESINA

According to VDW, DESINA standardisation

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

Typical application area ● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m and more Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] 4 G 1,5 4 G 2,5 4 G 4,0 4 G 6,0 5 G 6,0 4 G 10,0 5 G 10,0 4 G 16,0 5 G 16,0 4 G 25,0

CF37.15.04.D CF37.25.04.D CF37.40.04.D CF37.60.04.D CF37.60.05.D(1) CF37.100.04.D CF37.100.05.D(1) CF37.160.04.D CF37.160.05.D(1) CF37.250.04.D CF37.60.04.O.PE.D(1) CF37.100.04.O.PE.D(1) CF37.160.04.O.PE.D(1) CF37.500.03.O.PE.D

4 x 6,0 4 x 10,0 4 x 16,0 3 x 50,0

External diameter approx. [mm] 8,5 10,5 12,0 14,0 15,5 17,0 19,5 20,5 23,0 25,0 14,0 17,0 20,5 31,0

Copper index [kg/km] 58 96 158 239 285 411 517 633 800 994

Weight [kg/km]

239 411 633 1490

351 549 817 2028

109 162 239 351 420 549 687 817 1072 1266

(1) Delivery time upon inquiry. Other types available on request. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF37.250.04.D – in your desired length (0,5 m steps) CF37.D chainflex series .250 Code nominal cross section .04 Number of cores ®

Please use www.chainflex.eu/en/CF37 for your online order. Delivery time 24h or today.

Image exemplary.

Delivery time means time until shipping of goods.

eplan download, configurator

www.igus.eu/en/CF37

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

213


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:00 Seite 214

CF38 TPE 7,5 x d

TPE Power cable CF38 ● ● ● ● ● ● ●

Class 7.4.4 (7 maximum load requirements

for maximum load requirements TPE outer jacket shielded oil-resistant, biooil-resistant PVC-free/halogen-free UV-resistant hydrolysis-resistant and microbe-resistant

Conductor

Core insulation Core stranding Core identification

Inner jacket Overall shield

< 10 mm : Fine-wire stranded conductor in especially bendingresistant version consisting of bare copper wires (following EN 60228). ≥ 10 mm2: conductor cable consisting of pre-leads (following EN 60228). Mechanically high-quality, especially low-capacitance TPE mixture. Cores stranded in short pitch lengths over a centre for high tensile stresses. Energy conductor: Cores black with white numerals, one core green-yellow. 1. core: U / L1 / C / L+ 2. core: V / L2 3. core: W / L3 / D / L4. core: 4 / N TPE mixture adapted to suit the requirements in energy chains®.

T/R moved T/R fixed

-40 °C to +90 °C, minimum bending radius 4 x d

v max. 10 m/s, 6 m/s unsupported/gliding a max. 80 m/s2 Travel distance

Halogen-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

2

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Jet black (similar to RAL 9005) -35 °C to +90 °C, minimum bending radius 7,5 x d

Outer jacket

Silicon-free

UV-resistant

Freely suspended and gliding travel distances up to 400 m and more, Class 4 High

Nominal voltage

600/1000 V (following DIN VDE 0250).

Testing voltage

4000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4.

4 travel distance up to 400 m and more 4 oil-resistant)

CF38 TPE 7,5 x d

Typical application area ● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m and more Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] (4 G 0,5)C (4 G 0,75)C (4 G 1,5)C (4 G 2,5)C (4 G 4,0)C (4 G 6,0)C (4 G 10,0)C (4 G 16,0)C (4 G 25,0)C

CF38.05.04(1) CF38.07.04(1) CF38.15.04 CF38.25.04(1) CF38.40.04 CF38.60.04(1) CF38.100.04 CF38.160.04 CF38.250.04 CF38.60.03.O.PE(1) CF38.100.03.O.PE(1) CF38.160.03.O.PE(1) CF38.250.03.O.PE(1) CF38.350.03.O.PE(1) CF38.500.03.O.PE(1)

(3 x 6,0)C (3 x 10,0)C (3 x 16,0)C (3 x 25,0)C (3 x 35,0)C (3 x 50,0)C

External diameter approx. [mm] 8,0 8,5 9,5 11,5 13,5 16,0 19,5 23,0 27,5 14,5 17,5 21,0 24,5 28,5 33,5

Copper index [kg/km] 39 52 85 128 201 298 454 723 1160

Weight [kg/km]

231 356 553 884 1200 1660

367 568 789 1208 1675 2283

81 104 149 207 326 450 682 1003 1524

(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF38.25.04 – in your desired length (0,5 m steps) CF38 chainflex series .25 Code nominal cross section .04 Number of cores ®

Please use www.chainflex.eu/en/CF38 for your online order.

Image exemplary.

Delivery time 24h or today. eplan download, configurator

www.igus.eu/en/CF38

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Delivery time means time until shipping of goods.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

215


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:00 Seite 216

CF300.UL.D TPE 7,5 x d

TPE Power cable CF300.UL.D ● ● ● ● ● ●

Class 6.4.4

for maximum load requirements TPE outer jacket oil-resistant, biooil-resistant flame-retardant UV-resistant hydrolysis-resistant and microbe-resistant

Conductor

CF300.UL.D TPE (6 maximum load requirements 4 travel distance up to 400 m and more 4 oil-resistant) 7,5 x d

CE

Following 2006/95/EG

DESINA

According to VDW, DESINA standardisation

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, tested by IPA according to standard 14644-1

Conductor cable consisting of pre-leads (following EN 60228).

Typical application area Core insulation Outer jacket

Mechanically high-quality TPE mixture.

T/R moved

Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Jet black (similar to RAL 9005) -35 °C to +90 °C, minimum bending radius 7,5 x d

T/R fixed

-40 °C to +90 °C, minimum bending radius 4 x d

Torsion

Freely suspended and gliding travel distances up to 400 m and more, Class 4 ± 90 °, with 1 m cable length

UV-resistant

High

Nominal voltage

600/1000 V (following DIN VDE 0250).

Testing voltage

4000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Flame-retardant

for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m and more Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

Delivery program Part No.

v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2 Travel distance

● ● ● ● ●

CF300.UL.40.01.D CF300.UL.60.01.D CF300.UL.100.01.D CF300.UL.160.01.D CF300.UL.250.01.D CF300.UL.350.01.D CF300.UL.500.01.D CF300.UL.700.01.D CF300.UL.950.01.D CF300.UL.1200.01.D CF300.UL.1500.01.D CF300.UL.1850.01.D

Number of cores and conductor nominal cross section [mm2] 1x4,0 1x6,0 1x10,0 1x16,0 1x25,0 1x35,0 1x50,0 1x70,0 1x95,0 1x120,0 1x150,0 1x185,0

External diameter approx. [mm] 6,5 7,0 8,0 9,5 11,5 12,5 14,5 16,5 19,0 21,5 23,0 27,0

Copper index [kg/km] 38 56 96 151 239 333 479 623 848 1059 1318 1890

Weight [kg/km] 61 77 119 183 281 377 525 676 927 1145 1411 2014

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF300.UL.950.01.D – in your desired length (0,5 m steps) CF300.UL.D chainflex series .950 Code nominal cross section .01 Number of cores ®

Silicon-free UL/CSA

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Style 10492 and 21218, 1000 V, 80 °C

Please use www.chainflex.eu/en/CF300 for your online order. Delivery time 24h or today.

NFPA

Image exemplary.

CEI

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011) Following CEI 20-35

eplan download, configurator

Delivery time means time until shipping of goods.

www.igus.eu/en/CF300

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

217


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:00 Seite 218

CFPE TPE 7,5 x d

TPE Power cable CFPE ● ● ● ● ● ●

Class 6.4.4 (6 maximum load requirements

for maximum load requirements TPE outer jacket oil-resistant, biooil-resistant flame-retardant UV-resistant hydrolysis-resistant and microbe-resistant

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, tested by IPA according to standard 14644-1

Conductor cable consisting of pre-leads (following EN 60228).

Typical application area

Core insulation

Mechanically high-quality TPE mixture.

Core identification

Green-yellow

Outer jacket

T/R moved

Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Jet black (similar to RAL 9005) -35 °C to +90 °C, minimum bending radius 7,5 x d

● ● ● ● ●

T/R fixed

-40 °C to +90 °C, minimum bending radius 4 x d

Travel distance Torsion

Freely suspended and gliding travel distances up to 400 m and more, Class 4 ± 90 °, with 1 m cable length

UV-resistant

High

Nominal voltage

600/1000 V (following DIN VDE 0250).

Testing voltage

4000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Flame-retardant Silicon-free UL/CSA NFPA

Image exemplary.

CEI

Conductor

v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2

4 travel distance up to 400 m and more 4 oil-resistant)

CFPE TPE 7,5 x d

for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m and more Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] 1 G 1,5 1 G 2,5 1 G 4,0 1 G 6,0 1 G 10,0 1 G 16,0 1 G 25,0 1 G 35,0

CFPE.15.01 CFPE.25.01 CFPE.40.01 CFPE.60.01 CFPE.100.01 CFPE.160.01 CFPE.250.01 CFPE.350.01

External diameter approx. [mm] 5,0 6,0 6,5 7,0 8,0 9,5 11,5 13,0

Copper index [kg/km] 15 25 38 56 96 151 239 333

Weight [kg/km] 35 46 61 81 123 191 291 387

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CFPE.15.01 – in your desired length (0,5 m steps) CFPE chainflex series .15 Code nominal cross section .01 Number of cores ®

Please use www.chainflex.eu/en/CFPE for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Style 10492 and 21218, 1000 V, 80 °C Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

eplan download, configurator

www.igus.eu/en/CFPE

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

chainflex® CFPE for machining units. e-chain®: Serie E2 medium

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

219


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:00 Seite 220

CF310.UL TPE 7,5 x d

TPE Power cable CF310.UL ● ● ● ● ● ● ●

Class 6.4.4 (6 maximum load requirements

for maximum load requirements TPE outer jacket shielded oil-resistant, biooil-resistant flame-retardant UV-resistant hydrolysis-resistant and microbe-resistant

4 travel distance up to 400 m and more 4 oil-resistant)

CF310.UL TPE 7,5 x d

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, tested by IPA according to standard 14644-1

Typical application area Conductor

Conductor cable consisting of pre-leads (following EN 60228).

Core insulation

Mechanically high-quality TPE mixture.

Overall shield

T/R moved

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Jet black (similar to RAL 9005) -35 °C to +90 °C, minimum bending radius 7,5 x d

T/R fixed

-40 °C to +90 °C, minimum bending radius 4 x d

Outer jacket

v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2 Travel distance UV-resistant

Freely suspended and gliding travel distances up to 400 m and more, Class 4 High

Nominal voltage

600/1000 V (following DIN VDE 0250).

Testing voltage

4000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Flame-retardant

● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m and more Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

Delivery program Part No. * CF310.UL.25.01

CF310.UL.40.01 CF310.UL.60.01 CF310.UL.100.01 CF310.UL.160.01 CF310.UL.250.01 CF310.UL.350.01 CF310.UL.500.01 CF310.UL.700.01 CF310.UL.950.01 CF310.UL.1200.01 CF310.UL.1500.01 CF310.UL.1850.01

Number of cores and conductor nominal cross section [mm2] (1x2,5)C (1x4,0)C (1x6,0)C (1x10,0)C (1x16,0)C (1x25,0)C (1x35,0)C (1x50,0)C (1x70,0)C (1x95,0)C (1x120,0)C (1x150,0)C (1x185,0)C

External diameter approx. [mm] 6,5 6,5 7,5 8,5 10,0 11,5 13,5 15,0 17,5 20,5 22,0 24,0 28,0

Copper index [kg/km] 39 55 75 120 178 272 380 524 689 920 1140 1436 2020

Weight [kg/km] 61 74 97 144 210 314 423 568 748 997 1233 1549 2147

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF310.UL.40.01 – in your desired length (0,5 m steps) CF310.UL chainflex series .40 Code nominal cross section .01 Number of cores ®

Silicon-free UL/CSA NFPA

Image exemplary.

CEI

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Style 10492 and 21218, 1000 V, 80 °C Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011) Following CEI 20-35

eplan download, configurator

Please use www.chainflex.eu/en/CF310 for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.

www.igus.eu/en/CF310

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

221


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:00 Seite 222

CF330.D TPE 7,5 x d

TPE Power cable CF330.D ● ● ● ● ● ● ●

Class 7.4.4 (7 maximum load requirements

for maximum load requirements TPE outer jacket oil-resistant biooil-resistant PVC-free/halogen-free UV-resistant hydrolysis-resistant and microbe-resistant

Conductor

Conductor cable consisting of pre-leads (following EN 60228).

Core insulation

Mechanically high-quality TPE mixture.

Outer jacket

T/R moved

Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Jet black (similar to RAL 9005) -35 °C to +90 °C, minimum bending radius 7,5 x d

T/R fixed

-40 °C to +90 °C, minimum bending radius 4 x d

Clean room

4 travel distance up to 400 m and more 4 oil-resistant)

According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

Typical application area ● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m and more Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] 1x6,0 1x10,0 1x16,0 1x25,0 1x35,0 1x50,0 1x70,0 1x95,0 1x120,0 1x150,0 1x185,0

External diameter approx. [mm] 7,0 8,0 9,5 11,5 12,5 14,5 16,5 19,0 21,5 23,0 27,0

Copper index [kg/km] 56 96 151 239 333 479 623 848 1059 1318 1890

Torsion

Freely suspended and gliding travel distances up to 400 m and more, Class 4 ± 90 °, with 1 m cable length

CF330.60.01.D CF330.100.01.D CF330.160.01.D CF330.250.01.D CF330.350.01.D CF330.500.01.D CF330.700.01.D CF330.950.01.D CF330.1200.01.D CF330.1500.01.D CF330.1850.01.D

UV-resistant

High

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Nominal voltage

600/1000 V (following DIN VDE 0250).

Testing voltage

4000 V (following DIN VDE 0281-2).

Oil

Halogen-free

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

CE

Following 2006/95/EG

DESINA

According to VDW, DESINA standardisation

Lead free

Following 2011/55/EU (RoHS-II)

v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2 Travel distance

CF330.D TPE 7,5 x d

Weight [kg/km] 77 119 183 281 377 525 676 927 1145 1411 2014

Order example: CF330.160.01.D – in your desired length (0,5 m steps) CF330.D chainflex series .160 Code nominal cross section .01 Number of cores ®

Image exemplary.

Silicon-free

eplan download, configurator

www.igus.eu/en/CF330

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Please use www.chainflex.eu/en/CF330 for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.

STS cranes in Antwerp with igus® energy chain systems® for energy and data supplies to centenary and main trolley.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

223


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:00 Seite 224

CF340 TPE 7,5 x d

TPE Power cable CF340 ● ● ● ● ● ● ●

Class 7.4.4 (7 maximum load requirements

for maximum load requirements TPE outer jacket shielded oil-resistant, biooil-resistant PVC-free/halogen-free UV-resistant hydrolysis-resistant and microbe-resistant

Conductor

Mechanically high-quality TPE mixture.

Overall shield

T/R moved

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Jet black (similar to RAL 9005) -35 °C to +90 °C, minimum bending radius 7,5 x d

T/R fixed

-40 °C to +90 °C, minimum bending radius 4 x d

v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2 Travel distance UV-resistant

Typical application area ● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m and more Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

Conductor cable consisting of pre-leads (following EN 60228).

Core insulation

Outer jacket

4 travel distance up to 400 m and more 4 oil-resistant)

CF340 TPE 7,5 x d

Freely suspended and gliding travel distances up to 400 m and more, Class 4 High

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] (1x4,0)C (1x6,0)C (1x10,0)C (1x16,0)C (1x25,0)C (1x35,0)C (1x50,0)C (1x70,0)C (1x95,0)C (1x120,0)C (1x150,0)C (1x185,0)C

CF340.40.01 CF340.60.01(1) CF340.100.01(1) CF340.160.01 CF340.250.01(1) CF340.350.01(1) CF340.500.01 CF340.700.01 CF340.950.01(1) CF340.1200.01 CF340.1500.01 CF340.1850.01

External diameter approx. [mm] 6,5 7,5 8,5 10,0 11,5 13,5 15,0 17,5 20,5 22,0 24,0 28,0

Copper index [kg/km] 55 75 120 178 272 380 524 689 920 1140 1436 2020

Weight [kg/km] 74 97 144 210 314 423 568 748 1072 1233 1549 2147

(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF340.100.01 – in your desired length (0,5 m steps) CF340 chainflex series .100 Code nominal cross section .01 Number of cores ®

Nominal voltage

600/1000 V (following DIN VDE 0250).

Testing voltage

4000 V (following DIN VDE 0281-2).

Oil

Halogen-free

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

Image exemplary.

Silicon-free

eplan download, configurator

www.igus.eu/en/CF340

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Please use www.chainflex.eu/en/CF340 for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.

chainflex® CF340 for outdoor crane systems. e-chain®: Serie E4/00

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

225


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:00 Seite 226

CFCRANE igupren 10 x d

igupren Power cable CFCRANE ● ● ● ●

for maximum voltages and outputs igupren outer jacket oil-resistant flame-retardant

Conductor

● ● ● ● ●

T/R moved T/R fixed

-30 °C to +80 °C, minimum bending radius 7,5 x d

Overall shield Outer jacket

4 travel distance up to 500 m and more 3 oil-resistant)

Typical application area

Highly flexible cable consisting of tinned copper wires (following VDE 0295). Inner and outer semiconducting layer made of conductive rubber. Insulating sheath made of high-quality, heat-resistant and ozoneproof ethylene propylene rubber (EPR. Extremely bending-resistant, tinned copper shield. Coverage approx. 80% optical. Low-adhesion mixture on the basis of iguprene, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains® (following VDE 0207 Part 21). Colour: Red -20 °C to +80 °C, minimum bending radius 10 x d

Core insulation

Class 6.4.3 (6 maximum load requirements

CFCRANE igupren 10 x d

for maximum load requirements almost unlimited resistance to oil Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 500 m and more outdoor ship to shore, crane applications, conveyer technology

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] (1) CFCRANE1x25/16-6/10kV (1x25/16)C (1) CFCRANE1x35/16-6/10kV (1x35/16)C CFCRANE1x50/16-6/10kV(1) (1x50/16)C (1) CFCRANE1x70/16-6/10kV (1x70/16)C CFCRANE1x95/16-6/10kV(1) (1x95/16)C (1) (1x120/16)C New* CFCRANE1x120/16-6/10kV

External diameter approx. [mm] 27,0 29,0 30,0 32,0 34,0 35,0

Copper index [kg/km] 468 576 712 912 1145 1306

Weight [kg/km] 940 1110 1350 1550 1820 2100

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. x = without earth core G = with green-yellow earth core * New in this catalogue.

Order example: CFCRANE1x25/16-6/10kV – in your desired length (0,5 m steps) CFCRANE chainflex series .1 x 25/16 Code nominal cross section -6/10 Nominal voltage ®

Image exemplary.

v max. 10 m/s, 6 m/s unsupported/gliding a max. 50 m/s2

Please use www.chainflex.eu/en/CFCRANE for your online order. Delivery time 24h or today.

Travel distance

Freely suspended and gliding travel distances up to 500 m and more, Class 4

UV-resistant

High

Nominal voltage Testing voltage

6/10 kV (following DIN VDE 0250), other voltages upon inquiry. 17 kV (following DIN VDE 0250, Part 813).

Oil

Oil-resistant (following DIN EN 60811-2-1), Class 3.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free CE

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

eplan download, configurator

www.igus.eu/en/CFCRANE

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Delivery time means time until shipping of goods.

chainflex® CFCRANE for 500 m and more of travel. e-chain®: igus® rol e-chain®

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

227


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:01 Seite 228

CFAIR PU 10 x d

CFAIR PU 10 x d

Pneumatic hose CFAIR ● ● ● ● ● ●

for maximum load requirements PU hose oil-resistant and coolant-resistant abrasion-resistant outside-toleranced PVC-free/halogen-free

Delivery program Part No. CA PU.A.04.0 CA PU.A.06.0 CA PU.A.08.0 CA PU.A.10.0 CA PU.A.12.0 CA PU.A.16.0

T/R moved

-25 °C to +80 °C, minimum bending radius 10 x d

T/R fixed

-40 °C to +85 °C, minimum bending radius 8 x d

Max. package length [km] 2,0 1,5 1,0 1,0 0,5 0,1

Internal Wall External diameter thickness diameter approx. [mm] approx. [mm] approx. [mm] 2,7 0,65 4 4,0 1,00 6 5,7 1,15 8 7,0 1,50 10 8,0 2,00 12 11,0 2,50 16

Weight [g/m] 8 19 30 48 76 127

Order example: CA PU.A.04.0 – in your desired length (0,5 m steps) CA PU chainflex series .A Code material .04 Code Ø .0 Special identification ®

Please use www.chainflex.eu/en/CFCAPU for your online order.

v max. 10 m/s, 6 m/s unsupported/gliding a max. 50 m/s2 Dimensions

Delivery time 24h or today.

Outside-toleranced

Delivery time means time until shipping of goods.

Operating pressure 12 bar at 20 °C Vacuum

-1 bar at 20 °C

Oil

Oil-resistant

Halogen-free

Following EN 50267-2-1.

Material

Abrasion-resistant on the basis of Polyurethan adapted to suit the requirements in energy chains®. Colour: Blue Following 2011/55/EU (RoHS-II)

228

Image exemplary.

Lead free

eplan download, configurator

www.igus.eu/en/CAPU

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

igus® chainflex® CF Air pneumatic hoses were tested over several million bending cycles in e-chains®. Their outstanding features include flexibility, high abrasion resistance and very good resistance to oil and coolants.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

229


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:01 Seite 230

CFCleanAIR PE 10 x d

CFCleanAIR PE 10 x d

Pneumatic hose CFClean AIR ● ● ● ● ● ●

for maximum load requirements PE hose oil-resistant and coolant-resistant highly abrasion-resistant outside-toleranced PVC-free/halogen-free

Delivery program Part No. CA PE.A.04.0 CA PE.A.06.0 CA PE.A.08.0 CA PE.A.10.0 CA PE.A.12.0 CA PE.A.16.0

T/R moved

-25 °C to +60 °C, minimum bending radius 10 x d

T/R fixed

-30 °C to +65 °C, minimum bending radius 8 x d

Max. package length [km] 2,0 1,5 1,0 1,0 0,5 0,1

Internal Wall External diameter thickness diameter approx. [mm] approx. [mm] approx. [mm] 2,7 0,65 4 4,0 1,00 6 5,7 1,15 8 7,0 1,50 10 8,0 2,00 12 11,0 2,50 16

Weight [g/m] 6 15 21 38 54 90

Order example: CA PE.A.04.0 – in your desired length (0,5 m steps) CA PE chainflex series .A Code material .04 Code Ø .0 Special identification ®

Please use www.chainflex.eu/en/CFCAPE for your online order.

v max. 10 m/s, 6 m/s unsupported/gliding a max. 50 m/s2 Dimensions

Delivery time 24h or today. Delivery time means time until shipping of goods.

Outside-toleranced

Operating pressure 10 bar at 20 °C Vacuum

-0,95 bar at 20 °C

Oil

Oil-resistant

Halogen-free

Following EN 50267-2-1.

Material

Highly abrasion-resistant on the basis of Polyethylen adapted to suit the requirements in energy chains®. Colour: White Following 2011/55/EU (RoHS-II)

Lead free Clean room

igus® material abrasion test Comparison: abrasion of pneumatic hoses PUR, PE and PA in combination with igus® e-chains®*

According to ISO Class 1, material/cable tested by IPA according to ISO standard 14644-1

● for especially high abrasion resistance ● clean room, semi-conductor industry, handling

Abrasion in mm

Typical application area PUR hose PE hose 10x1,5 PA hose

230

Image exemplary.

Double strokes

eplan download, configurator

www.igus.eu/en/CAPE

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

* igus® e-chain® with opening link 450.30

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

231


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:01 Seite 232

Page

a max. [m/s2]

v max. [m/s] gliding

v max. [m/s] unsupported

Oil-resistant

Approvals and standards

Temperature moved from/to [°C]

Minimum bending radius, moved [factor x d]

Shield

Jacket

chainflex® cable

chainflex type

Torsion resistant

®

Torsion-resistant cables Information torsion-resistant cables

234

Hybrid cable/Control cable CF ROBOT9

PUR

CF77.UL.D

PUR

CF ROBOT2

PUR

PUR

10,0

-25/ +80

10

10

236

10,0

-35/ +80

10

10

238

New*

10,0

-25/ +80

10

10

242

New*

10,0

-20/ +70

10

10

244

10,0

-25/ +80

10

10

246

12,5

-20/ +60

10

10

248

10,0

-25/ +80

10

10

250

Bus cable CF ROBOT8

Measuring system cable CF ROBOT4

PUR

Fibre optic cable

Torsion-resistant cables

Robot

CF ROBOT5

TPE

Power cable/Servo cable CF ROBOT6

PUR

CF ROBOT7

PUR

10,0

-25/ +80

10

10

250

CF ROBOT

TPE

10,0

-35/ +100

10

10

252

* New in this catalogue

233


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:02 Seite 234

Info

Info

chainflex® cables for robots

Ever more complex sequences of movements in industrial applications demand twistable and/or three-dimensional flexible cables with a long service life similar to the classic chainflex® cables for use in linear e-chainsystems®. Wires, stranded, shields and sheathing materials must compensate both major changes in bending load and changes in diameter due to torsional movements. For this purpose, different "soft" structural elements e.g. rayon fibres, PTFE elements or filling elements that absorb torsion forces are used in chainflex® ROBOT cables.

To enable evaluation to take place nevertheless, based on sensible and comparable test results, the igus® "torsion test standard" was developed. According to this standard, all chainflex® ROBOT cables of a triflex® R energy chain® are twisted with a fixed-point distance of one metre and a torsion of +/- 180° at least 3 million times. In addition, a test is carried out on a test bench with a chain length of approx. 2500 mm with 270° torsion with an extreme load through centrifugal forces and heavy blows such as those that can occur with an industrial robot.

Special demands are made on the braided shielding in torsion cables. Torsion-optimised shield structures are chosen that can carry out the necessary compensatory movements thanks to special PTFE gliding films.

All the non-shielded, gusset-filled extruded standard chainflex® control cables of the series CF5, CF77.UL.D and CF 9 correspond to the above-mentioned igus® standard and have been approved for use in torsion applications. The following twistable CF ROBOT cable types are currently available: ● Hybrid/Control cables ● Motor/Servo cables ● Bus/Data cables ● FOC cables We can also offer you chainflex® ROBOT cables pre-fitted with the plug-in connectors of your choice as readycable®, or as a ready-to-install readychain® cable assembly.

With twistable bus cables in particular, the transmission characteristics such as attenuation, cable capacity and signal quality must remain within very tight tolerance ranges over the whole service life.

Test data Page 55 or www.igus.eu/en/test15

This is achieved through the use of particularly torsionoptimised insulating materials and mechanical attenuation elements with matching capacity values. The highly abrasion-resistant, halogen-free and flameresistant PUR sheathing mixture in motor, hybrid/control cables and bus cables protects the torsion-optimised stranded elements from possible damage. The highly abrasion-resistant, halogen-free TPE-sheath mixture matches the special requirements of the twistable FOC and individual wires, and also protects the stranded elements. Unlike cables for linear e-chainsystems®, the "mechanical stress" for these cables is in the combination of bending, torsion and centrifugal forces that cannot usually be determined by design in advance or during use by means of measurement. For this reason, and unlike the situation with linear e-chain® applications, a clear "yes/no" statement cannot be made about the possibility of using a certain cable in torsion applications.

950 types from stock no cutting costs ... 234

(for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

235


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:02 Seite 236

CFROBOT9 PUR ± 180°

PUR Hybrid cable, twistable CFROBOT9 ● ● ● ● ● ● ●

Class 6.1.3 (6 maximum load requirements

for twistable loads PUR outer jacket unshielded/shielded oil-resistant and coolant-resistant notch-resistant flame-retardant hydrolysis-resistant and microbe-resistant

UL/CSA NFPA Clean room

1 freely suspended 3 oil-resistant)

CFROBOT9 PUR ± 180°

> 0,5 mm2: Style 10493 and 20317, 300 V, 80 °C – starting from manufacturing date 5/2011 ≤ 0,5 mm2: Style 10467 and 20317, 300 V, 80 °C – starting from manufacturing date 5/2011 Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011) According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1

Typical application area Conductor Core insulation Element shield

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture.

T/R moved

Extremely torsion resistant tinned braided copper shield. Coverage approx. 85% optical. Low-adhesion, halogen-free, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Steel blue (similar to RAL 5011) -25 °C to +80 °C, minimum bending radius twisted 10 x d

T/R fixed

-40 °C to +80 °C, minimum bending radius 4 x d

v max. twisted a max.

10 m/s 10 m/s2

Travel distance

Robots and movements in the 3D range, Class 1

Torsion

± 180 °, with 1 m cable length

UV-resistant

High

Nominal voltage

300/500 V (following DIN VDE 0245).

Testing voltage

2000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free CEI

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Outer jacket

● ● ● ● ●

for maximum load requirements with torsion movements almost unlimited resistance to oil indoor and outdoor applications, UV-resistant especially for robots and movements in the 3D range robots, handling, spindle drives

Delivery program Part No. CFROBOT9.001 CFROBOT9.002 CFROBOT9.003 CFROBOT9.004 CFROBOT9.005(1) CFROBOT9.006 CFROBOT9.007

Number of cores and conductor nominal cross section [mm2] 5 G 1,0 + (2x1,0)C 2x3x0,75 + (3x0,75)C 2x0,5 + (2x0,5)C 16 G 1,0 + (2x1,0)C 23 G 1,0 + (2x1,0)C 24 G 1,0 + (2x1,0)C (15x(2x0,25)C + (4x0,25)C)C

External diameter approx. [mm] 9,5 12,0 10,0 18,5 19,5 20,0 18,0

CFROBOT9.001

Number of cores and conductor nominal cross section [mm2] 5 G 1,0 + (2x1,0)C

Core group

5G1,0

CFROBOT9.002

2x3x0,75 + (3x0,75)C

CFROBOT9.003

2x0,5 + (2x0,5)C

CFROBOT9.004

16 G 1,0 + (2x1,0)C

(2x1,0)C 2x3x0,75 (3x0,75)C 2x0,5 (2x0,5)C 16G1,0

CFROBOT9.005

23 G 1,0 + (2x1,0)C

(2x1,0)C 23G1,0

24 G 1,0 + (2x1,0)C

(2x1,0)C 24G1,0

CFROBOT9.006

(2x1,0)C CFROBOT9.007 (15x(2x0,25)C + (4x0,25)C)C 15x(2x0,25)C (4x0,25)C Image exemplary.

Weight [kg/km] 129 143 75 326 478 484 330

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Part No.

eplan download, configurator

Copper index [kg/km] 75 76 27 177 241 251 217

Colour code

Cores white with black numerals 3-6, one core green-yellow Cores white with black numerals 1-2 Cores white with black numerals 4-9 Cores white with black numerals 1-3 blue, black white, brown Cores white with black numerals 1-4, 7-17, one core green-yellow Cores white with black numerals 5-6 Cores white with black numerals 1-4, 7-24, one core green-yellow Cores white with black numerals 5-6 Cores white with black numerals 1-4, 7-25, one core green-yellow Cores white with black numerals 5-6 Colour code nach DIN47100 white, green, brown, yellow (CAN-Bus)

www.igus.eu/en/CFROBOT

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

237


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:02 Seite 238

CF77.UL.D PUR ± 180°

PUR Control cable, twistable CF77.UL.D ● ● ● ● ● ● ●

for twistable loads PUR outer jacket oil-resistant and coolant-resistant notch-resistant flame-retardant hydrolysis-resistant and microbe-resistant PVC-free/halogen-free

Conductor Core insulation Core stranding

Fine-wire stranded conductor consisting of bare copper wires (following EN 60228) Mechanically high-quality TPE mixture.

T/R moved

Number of cores < 12: cores stranded in a layer with short pitch length. Number of cores ≥ 12: cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially lowtorsion structure. Cores < 0,5 mm2: Colour code in accordance with DIN 47100 Cores ≥ 0,5 mm2: Cores black with white numerals, one core green-yellow CF77.UL.03.04.INI: brown, blue, black, white Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Window gray (similar to RAL 7040) CF77.UL.03.04.INI: Colour: Colza yellow (similar to RAL 1021) -35 °C to +80 °C, minimum bending radius twisted 10 x d

T/R fixed

-40 °C to +80 °C, minimum bending radius 4 x d

v max. twisted a max.

10 m/s 10 m/s2

Travel distance

Robots and movements in the 3D range, Class 3

Torsion

± 180 °, with 1 m cable length

UV-resistant

Medium

Nominal voltage

Number of cores < 12: 300/500 V Number of cores < 12 (0,25-0,34): 300/300 V Number of cores ≥ 12: 300/300 V (following DIN VDE 0245) 2000 V (following DIN VDE 0281-2)

Core identification

Outer jacket

Testing voltage

Image exemplary.

Class 5.3.3 (5 high load requirements

eplan download, configurator

3 travel distance up to 100 m 3 oil-resistant)

CF77.UL.D PUR ± 180°

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

Offshore

MUD-resistant following NEK 606 – status 2009.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free Halogen-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992) Following EN 50267-2-1

UL/CSA

Style 10493 and 20233, 300 V, 80 °C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

DESINA

According to VDW, DESINA standardisation

Lead free

Following 2011/55/EU (RoHS-II)

Typical application area ● ● ● ● ●

for maximum load requirements with torsion movements almost unlimited resistance to oil indoor and outdoor applications with average sun radiation especially for robots and movements in the 3D range robots, handling, spindle drives

www.igus.eu/en/CF77R

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

239


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:02 Seite 240

CF77.UL.D PUR ± 180°

PUR Control cable, twistable CF77.UL.D

Class 5.3.3 (5 high load requirements

3 travel distance up to 100 m 3 oil-resistant)

CF77.UL.D PUR ± 180°

Image exemplary.

Delivery program Part No. CF77.UL.02.04.D CF77.UL.03.04.INI CF77.UL.05.04.D CF77.UL.05.05.D CF77.UL.05.07.D CF77.UL.05.12.D CF77.UL.05.18.D CF77.UL.05.25.D CF77.UL.05.30.D CF77.UL.07.03.D CF77.UL.07.04.D CF77.UL.07.05.D CF77.UL.07.07.D CF77.UL.07.12.D CF77.UL.07.18.D CF77.UL.07.20.D CF77.UL.07.36.D CF77.UL.07.42.D(1) CF77.UL.10.02.D CF77.UL.10.03.D CF77.UL.10.04.D CF77.UL.10.05.D CF77.UL.10.07.D CF77.UL.10.12.D CF77.UL.10.18.D CF77.UL.10.25.D CF77.UL.15.03.D CF77.UL.15.04.D CF77.UL.15.05.D CF77.UL.15.07.D(17) CF77.UL.15.12.D CF77.UL.15.18.D CF77.UL.15.25.D CF77.UL.15.36.D(1) CF77.UL.15.42.D(1)

Number of cores and conductor nominal cross section [mm2] 4 x 0,25 4 x 0,34 4 G 0,5 5 G 0,5 7 G 0,5 12 G 0,5 18 G 0,5 25 G 0,5 30 G 0,5 3 G 0,75 4 G 0,75 5 G 0,75 7 G 0,75 12 G 0,75 18 G 0,75 20 G 0,75 36 G 0,75 42 G 0,75 2 x 1,0 3 G 1,0 4 G 1,0 5 G 1,0 7 G 1,0 12 G 1,0 18 G 1,0 25 G 1,0 3 G 1,5 4 G 1,5 5 G 1,5 7 G 1,5 12 G 1,5 18 G 1,5 25 G 1,5 36 G 1,5 42 G 1,5

External diameter approx. [mm] 5,5 6,0 6,0 6,5 7,5 10,0 12,0 13,5 14,5 6,0 6,5 7,0 8,5 11,5 13,5 14,0 19,0 20,5 6,0 6,5 7,0 7,5 8,5 11,5 14,5 17,0 7,0 7,5 8,0 10,0 14,0 17,0 19,5 23,5 25,5

Copper index [kg/km] 10 15 19 24 37 57 86 119 143 21 28 35 49 84 126 140 284 331 20 29 39 49 68 116 174 240 42 55 69 96 165 260 360 567 662

Weight [kg/km] 34 38 48 55 76 128 188 244 297 52 61 71 100 183 247 277 497 570 52 61 75 91 112 222 321 406 81 99 117 164 290 397 555 837 973

Delivery program Part No.

New*

New*

External diameter approx. [mm] 8,5 9,0 10,5 12,5 11,5

Copper index [kg/km] 80 91 120 168 154

Weight [kg/km] 108 145 179 253 242

New*

(1) Delivery time upon inquiry. (17) Using the cables with "7 G 1,5 mm2" and "7 G 2,5 mm2" it is essential: bending radius 17 x d with travel distance ≥ 5 m. When the travel distance is not less than 5 m, a bending radius not less than 17 x d has to be used. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalogue.

Order example: CF77.UL.10.03.D – in your desired length (0,5 m steps) CF77.UL.D chainflex series .10 Code nominal cross section .03 Number of cores ®

Please use www.chainflex.eu/en/CF77R for your online order. Delivery time 24h or today. New*

Delivery time means time until shipping of goods.

New* New*

(1) Delivery time upon inquiry. (17) Using the cables with "7 G 1,5 mm2" and "7 G 2,5 mm2" it is essential: bending radius 17 x d with travel distance ≥ 5 m. When the travel distance is not less than 5 m, a bending radius not less than 17 x d has to be used. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalogue.

950 types from stock no cutting costs ... 240

CF77.UL.25.03.D CF77.UL.25.04.D CF77.UL.25.05.D CF77.UL.25.07.D(17) CF77.UL.40.04.D(1)

Number of cores and conductor nominal cross section [mm2] 3 G 2,5 4 G 2,5 5 G 2,5 7 G 2,5 4 G 4,0

(for up to 10 cuts of the same type)

eplan download, configurator

www.igus.eu/en/CF77R

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

241


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:02 Seite 242

CFROBOT2 PUR ± 180°

PUR Control cable, twistable CFROBOT2 ● ● ● ● ● ● ●

for twistable loads PUR outer jacket shielded oil-resistant and coolant-resistant notch-resistant flame-retardant hydrolysis-resistant and microbe-resistant

Conductor Core insulation Element shield

New!

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture.

T/R moved

Extremely torsion resistant tinned braided copper shield. Coverage approx. 85% optical. Low-adhesion, halogen-free, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Steel blue (similar to RAL 5011) -25 °C to +80 °C, minimum bending radius twisted 10 x d

T/R fixed

-40 °C to +80 °C, minimum bending radius 4 x d

Outer jacket

Class 6.1.3 (6 maximum load requirements CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1

Typical application area ● ● ● ● ●

for maximum load requirements with torsion movements almost unlimited resistance to oil indoor and outdoor applications, UV-resistant especially for robots and movements in the 3D range Robots, handling, spindle drives

Delivery program Part No. New* CFROBOT2.07.04.C(1)

v max. twisted a max.

10 m/s 10 m/s2

Travel distance

Robots and movements in the 3D range, Class 1

Torsion

± 180 °, with 1 m cable length

UV-resistant

High

1 freely suspended 3 oil-resistant)

CFROBOT2 PUR ± 180°

New* CFROBOT2.07.05.C

(1)

New* CFROBOT2.07.12.C(1) New* CFROBOT2.07.18.C(1)

Number of cores and conductor nominal cross section [mm2] (4 G 0,75)C (5 G 0,75)C (12 G 0,75)C (18 G 0,75)C

External diameter approx. [mm] 7,5 8,0 13,5 16,5

Copper index [kg/km] 44 53 130 186

Weight [kg/km] 80 92 219 311

(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalogue.

Esempio codice articolo: CFROBOT2.07.05.C – Lunghezza secondo vs. richiesta (passo 0,5 m) CFROBOT2 chainflex series .07 Code nominal cross section .05 Number of cores .C shielded ®

Nominal voltage

300/500 V (following DIN VDE 0245)

Testing voltage

2000 V (following DIN VDE 0281-2)

Please use www.chainflex.eu/en/CF77R for your online order. Delivery time 24h or today.

Image exemplary.

Delivery time means time until shipping of goods.

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free UL/CSA

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Style 10493 and 20317, 300 V, 80 °C

NFPA

Following NFPA 79-2012 chapter 12.9

eplan download, configurator

www.igus.it/it/CFROBOT

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

243


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:02 Seite 244

CFROBOT8 PUR ± 180°

PUR Bus cable, twistable CFROBOT8 ● ● ● ● ● ● ●

Class 6.1.3 (6 maximum load requirements

for twistable loads PUR outer jacket shielded oil-resistant notch-resistant flame-retardant hydrolysis-resistant and microbe-resistant

1 freely suspended 3 oil-resistant)

CFROBOT8 PUR ± 180°

CE

Following 2006/95/EG

Lead free

Following 2002/95/EG (RoHS).

UL

> 0,25 mm2: Style 1589 and 20963, 30 V, 80 °C – starting from manufacturing date 5/2011 ≤ 0,25 mm2: Style 1589 and 20236, 30 V, 80 °C – starting from manufacturing date 5/2011

Typical application area Conductor Core insulation

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). According to bus specification

Core stranding

According to bus specification

According to bus specification Schedule Delivery Program Intermediate jacket Foil taping over the external layer.

● ● ● ● ●

for maximum load requirements with torsion movements almost unlimited resistance to oil, also with bio-oils indoor and outdoor applications, UV-resistant especially for robots and movements in the 3D range robots, handling, spindle drives

Core identification

Overall shield

T/R moved

Torsion resistant tinned braided copper shield. Coverage approx. 80% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains®. Colour: Steel blue (similar to RAL 5011) -20 °C to +70 °C, minimum bending radius twisted 10 x d

T/R fixed

-25 °C to +70 °C, minimum bending radius 7,5 x d

v max. twisted a max.

10 m/s 10 m/s2

Travel distance

Robots and movements in the 3D range, Class 1

Torsion

± 180 °, with 1 m cable length

UV-resistant

High

Nominal voltage

30 V

Testing voltage

500 V

Oil

Oil-resistant (following DIN EN 50363 -10-2), Class 3.

Outer jacket

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] CFROBOT8.001 (Profibus) (2x0,35)C CFROBOT8.022 (Can-Bus) (4x0,5)C CFROBOT8.045 (GigE) 4x(2x0,14)C New* CFROBOT8.060 (Profinet) (2x(2x0,34))C

External diameter approx. [mm] 8,0 7,0 8,5 8,0

Copper index [kg/km] 22 39 35 67

Weight [kg/km] 57 65 65 37

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalogue.

Part No.

Characteristic Number of cores and Colour code wave impedance conductor nominal approx. [Ω] cross section [mm2] CFROBOT8.001 150 (2x0,35)C red, green CFROBOT8.022 120 (4x0,5)C white, green, brown, yellow (star-quad stranding) CFROBOT8.045 100 (4x(2x0,14)C) white-blue/blue, white-orange/orange, white-green/green, white-brown/brown CFROBOT8.060 100 (2x(2x0,34))C white/blue, yellow/orange

Order example: CFROBOT8.001 – in your desired length (0,5 m steps) CFROBOT8 chainflex series .001 Code nominal cross section ®

Please use www.chainflex.eu/en/CFROBOT for your online order. Delivery time 24h or today.

Image exemplary.

Delivery time means time until shipping of goods.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1

Silicon-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).

eplan download, configurator

www.igus.eu/en/CFROBOT

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

245


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:02 Seite 246

CFROBOT4 PUR ± 180°

PUR Measuring system cable, twistable CFROBOT4 ● ● ● ● ● ● ●

Class 6.1.3 (6 maximum load requirements

for twistable loads PUR outer jacket shielded oil-resistant and coolant-resistant notch-resistant flame-retardant hydrolysis-resistant and microbe-resistant

Conductor Core insulation Element shield Outer jacket

T/R moved

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture. Extremely torsion resistant tinned braided copper shield. Coverage approx. 85% optical. Low-adhesion, halogen-free, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Steel blue (similar to RAL 5011) -25 °C to +80 °C, minimum bending radius twisted 10 x d

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1

Typical application area ● ● ● ● ●

for maximum load requirements with torsion movements almost unlimited resistance to oil indoor and outdoor applications, UV-resistant especially for robots and movements in the 3D range robots, handling, spindle drives

Delivery program Part No. CFROBOT4.001

T/R fixed v max. twisted a max.

-40 °C to +80 °C, minimum bending radius 4 x d CFROBOT4.002(1) CFROBOT4.009 CFROBOT4.015 CFROBOT4.028(16)

10 m/s 10 m/s2

1 freely suspended 3 oil-resistant)

Number of cores and conductor nominal cross section [mm2] (3x(2x0,14)C+ (4x0,14) + (2x0,5))C (3x(2x0,14)C + 2x(0,5)C)C (4x(2x0,25) + (2x0,5))C (4x(2x0,14) + 4x0,5)C (2x(2x0,15) + (2x0,38))C

External diameter approx. [mm] 11,0 10,5 9,5 9,5 7,5

Travel distance

Robots and movements in the 3D range, Class 1

(1) Delivery time upon inquiry. (16) Colour outer jacket: Yellow green (similar to RAL 6018) Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Torsion

± 180 °, with 1 m cable length

Part No.

UV-resistant

High

Nominal voltage

30 V

Testing voltage

500 V

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Style 1589 and 20236, 30 V, 80 °C – starting from manufacturing date 5/2011 Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

UL/CSA NFPA

CFROBOT4 PUR ± 180°

Number of cores and Core group conductor nominal cross section [mm2] CFROBOT4.001 (3x(2x0,14)C + (4x0,14) + (2x0,5))C 3x(2x0,14)C 4x0,14 2x0,5 CFROBOT4.002 (3x(2x0,14)C + 2x(0,5)C)C 3x(2x0,14)C 2x(0,5)C CFROBOT4.009 (4x(2x0,25) + (2x0,5))C 4x(2x0,25) 2x0,5 CFROBOT4.015 (4x(2x0,14) + 4x0,5)C 4x(2x0,14) 4x0,5 CFROBOT4.028 (2x(2x0,15) + (2x0,38))C 2x(2x0,15) (2x0,38)

Copper index [kg/km]

Weight [kg/km]

65 67 53 54 42

166 128 102 106 72

Colour code

green/yellow, black/brown, red/orange gray, blue, white-yellow, white-black brown-red, brown-blue green/yellow, black/brown, red/orange black, red brown/green, blue/violet, gray/pink, red/black white, brown brown/green, violet/yellow, gray/pink, red/black blue, white, brown-green, white-green green/yellow, pink/blue red, black

Order example: CFROBOT4.009 – in your desired length (0,5 m steps) CFROBOT4 chainflex series .009 Code Measuring system ®

Please use www.chainflex.eu/en/CFROBOT for your online order.

Image exemplary.

Delivery time 24h or today. eplan download, configurator

www.igus.eu/en/CFROBOT

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Delivery time means time until shipping of goods.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

247


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:02 Seite 248

CFROBOT5 TPE ± 180°

TPE Fibre optic cable, twistable CFROBOT5 ● ● ● ● ● ● ●

for twistable loads TPE outer jacket oil-resistant biooil-resistant UV-resistant low-temperature-flexible hydrolysis-resistant and microbe-resistant

Fibre cable

Class 7.1.4 (7 maximum load requirements Typical application area ● ● ● ● ●

for maximum load requirements with torsion movements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for robots and movements in the 3D range robots, handling

Delivery program Part No.

Number of fibres

CFROBOT5.500 CFROBOT5.501

2 2

T/R moved

50/125 µm, 62.5/125 µm special fixed wire elements with aramide strain relief. FOC wires stranded with high-tensile aramide dampers around the GRP central element. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Steel blue (similar to RAL 5011) -20 °C to +60 °C, minimum bending radius twisted 12,5 x d

T/R fixed

-25 °C to +60 °C, minimum bending radius 7,5 x d

CFROBOT5.500 CFROBOT5.501

v max. twisted a max.

10 m/s

Core stranding Outer jacket

1 freely suspended 4 oil-resistant)

CFROBOT5 TPE ± 180°

Fibre diameter approx. [µm] 62,5/125 50/125

External diameter approx. [mm] 8,5 8,5

Weight [kg/km] 87 87

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.

Part No.

Bandwidth Attenuation Bandwidth Attenuation Colour code with 650 nm with 650 nm with 1300 nm with 1300 nm [MHz x km] [dB/km] [MHz x km] [dB/km] 160 - 200 3,2 200 - 500 0,9 orange with white numbers 200 - 600 2,5 - 3,5 600 - 1200 0,7 - 1,5 blue with white numbers

Order example: CFROBOT5.501 – in your desired length (0,5 m steps) CFROBOT5 chainflex series .501 Code Type of fibres

10 m/s2

®

Travel distance

Robots and movements in the 3D range, Class 1

Torsion

± 180 °, with 1 m cable length

UV-resistant

High

Oil

CE

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

Image exemplary.

Silicon-free

eplan download, configurator

Please use www.chainflex.eu/en/CFROBOT for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.

www.igus.eu/en/CFROBOT

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

249


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:02 Seite 250

CFROBOT6/7 PUR ± 180°

PUR Power cable, twistable CFROBOT6/7 ● ● ● ● ● ● ●

Class 6.1.3 (6 maximum load requirements

for twistable loads PUR outer jacket unshielded/shielded oil-resistant and coolant-resistant notch-resistant flame-retardant hydrolysis-resistant and microbe-resistant

Conductor Core insulation Core identification

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture.

T/R moved

Energy conductor: Cores black with white numerals, one core green-yellow Schedule Delivery Program 2 signal pairs: Cores black with white numerals. 1. control core: 5 2. control core: 6 3. control core: 7 4. control core: 8 4 signal pairs: Colour code in accordance with DIN 47100 Extremely torsion resistant tinned braided copper shield. Coverage approx. 85% optical. Low-adhesion, halogen-free, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Steel blue (similar to RAL 5011) -25 °C to +80 °C, minimum bending radius twisted 10 x d

T/R fixed

-40 °C to +80 °C, minimum bending radius 4 x d

v max. twisted a max.

10 m/s 10 m/s2

Travel distance

Robots and movements in the 3D range, Class 1

Torsion

± 180 °, with 1 m cable length

UV-resistant

High

Nominal voltage

600/1000 V (following DIN VDE 0250).

Testing voltage

4000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).

Overall shield Outer jacket

1 freely suspended 3 oil-resistant)

CFROBOT6/7 PUR ± 180°

UL/CSA

Style 10492 and 21223, 1000 V, 80 °C – starting from manufacturing date 5/2011

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1

Typical application area ● ● ● ● ●

for maximum load requirements with torsion movements almost unlimited resistance to oil indoor and outdoor applications, UV-resistant especially for robots and movements in the 3D range robots, handling, spindle drives

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] 3 G 10 3 G 16 3 G 25 3 G 35

CFROBOT6.100.03(12) CFROBOT6.160.03(12) CFROBOT6.250.03(12) CFROBOT6.350.03(12) Without signal pair CFROBOT7.15.03.C(12) (3 G 1,5)C CFROBOT7.25.03.C(12) (3 G 2,5)C (13) CFROBOT7.15.04.C (4 G 1,5)C CFROBOT7.25.04.C(13) (4 G 2,5)C (13) New* CFROBOT7.60.04.C (4 G 6,0)C 2 signal pairs CFROBOT7.15.15.02.02.C(14) (4 G 1,5 + 2x(2x1,5)C)C CFROBOT7.25.15.02.02.C(1/14) (4 G 2,5 + 2x(2x1,5)C)C 4 signal pairs CFROBOT7.40.02.02.04.C(14) (4 G 4 + 4x(2x0,25)C)C

External diameter approx. [mm] 16,5 19,0 23,5 26,0

Copper index [kg/km] 287 459 722 1020

Weight [kg/km] 404 601 926 1233

8,0 9,5 8,5 10,5 15,0

58 89 74 115 296

95 137 121 171 376

16,5 18,5

190 230

380 450

16,5

240

340

(1) Delivery time upon inquiry (12) Core identification energy conductor: 1. core: 1 2. core: 2 (13) Core identification energy conductor: 1. core: 1 2. core: 2 3. core: 3 (14) Core identification energy conductor: 1. core: U / L1 / C / L+ 2. core: V / L2 3. core: W / L3 / D / LNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalogue.

Order example: CFROBOT6.100.03 – in your desired length (0,5 m steps) CFROBOT6 chainflex series .100 Code nominal cross section .03 Number of cores ®

Please use www.chainflex.eu/en/CFROBOT for your online order.

Image exemplary.

Delivery time 24h or today. eplan download, configurator

www.igus.eu/en/CFROBOT

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Delivery time means time until shipping of goods.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

251


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:02 Seite 252

CFROBOT TPE ± 180°

TPE Robot cable, twistable CFROBOT ● ● ● ● ● ● ● ●

Class 6.1.4 (6 maximum load requirements

for twistable loads TPE outer jacket shielded oil-resistant, biooil-resistant PVC-free UV-resistant flame-retardant hydrolysis-resistant and microbe-resistant Conductor

1 freely suspended 4 oil-resistant)

CFROBOT TPE ± 180°

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, tested by IPA according to standard 14644-1

Extremely bend-resistant cable.

Typical application area Core insulation Overall shield

Mechanically high-quality TPE mixture.

T/R moved

Extremely torsion resistant tinned braided copper shield. Coverage approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Jet black (similar to RAL 9005) -35 °C to +100 °C, minimum bending radius twisted 10 x d

T/R fixed

-40 °C to +100 °C, minimum bending radius 4 x d

v max. twisted a max.

10 m/s

Outer jacket

10 m/s2

Travel distance

Robots and movements in the 3D range, Class 1

Torsion

± 180 °, with 1 m cable length

● ● ● ● ●

for maximum load requirements with torsion movements almost unlimited resistance to oil, also with bio-oils indoor and outdoor applications, UV-resistant especially for robots and movements in the 3D range robots, handling, spindle drives

Delivery program Part No. CFROBOT.035 CFROBOT.036 CFROBOT.037 CFROBOT.038 CFROBOT.039

Number of cores and conductor nominal cross section [mm2] (1x10,0)C (1x16,0)C (1x25,0)C (1x35,0)C (1x50,0)C

External diameter approx. [mm] 10,5 12,0 14,5 15,5 18,0

Copper index [kg/km] 121 183 289 391 546

Weight [kg/km] 197 274 425 534 726

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CFROBOT.035 – in your desired length (0,5 m steps) CFROBOT chainflex series .035 Code nominal cross section ®

UV-resistant

High

Nominal voltage

600/1000 V (following DIN VDE 0250).

Please use www.chainflex.eu/en/CFROBOT for your online order. Delivery time 24h or today.

Testing voltage

4000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Flame-retardant Silicon-free UL/CSA

Image exemplary.

NFPA

Delivery time means time until shipping of goods.

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Style 10258 and 21387, 1000 V, 90 °C Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

eplan download, configurator

www.igus.eu/en/CFROBOT

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

igus® chainflex® cables in application of a multi-dimensional moving energy supply triflex® R for production robots.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

253


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:02 Seite 254

®

Special cable

Page

chainflex® cable

Approvals and standards

chainflex type Special cables Data cables CF THERMO

Thermocouple cable

256

CF THERMO

Thermocouple cable – ready-made

258

CF FLAT

Single core flat cables

260

CF BRAID

Braided cores

262

Cables for hanging applications

264

New*

Cables for rail vehicles

265

New*

Power cables

Bus cables CFSP182 Control cables CFSP414

The following chapter of special cables offers solutions for moved applications going beyond standard energy supply applications. The constantly growing program of the special cables follows your special demands and we would like to offer solutions for that. It is at the same time an inspiration for users. igus® can make cables for special applications and can fall back on most different materials and production processes. Depending to the construction this is already possible from a length of 500 m.

* New in this catalogue.

Use our comprehensive knowledge about cable plus the experience of 2 billion test cycles that are annually realized in the company-owned chainflex® laboratory. The technical and material details of the CFSP families are documented data sheets of the respective cables and are at any time available up-to-date in the internet. The respective web links can be recalled on the summary pages of the CFSP cables. We look foreword to hear about your job definition!

255


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:02 Seite 256

CFTHERMO PUR 12,5 - 15 x d

PUR Thermocouple cable CFTHERMO ● ● ● ● ● ● ●

Class 5.2.3 (5 high load requirements

for high load requirements PUR outer jacket oil-resistant and coolant-resistant notch-resistant PVC-free/halogen-free flame-retardant hydrolysis-resistant and microbe-resistant

Conductor Core insulation

Silicon-free

CFTHERMO PUR 12,5 - 15 x d

2 travel distance up to 50 m 3 oil-resistant)

Halogen-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1

Conductor consisting of a flexible special alloy Schedule Delivery Program Mechanically high-quality TPE mixture.

Typical application area Core stranding

The individual cores are stranded in layers with short pitch lengths. Core identification According to thermo specification Schedule Delivery Program Overall shield Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Intermediate jacket Fleece taping over the external layer. Outer jacket

T/R moved

T/R fixed

Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: According to thermo specification Schedule Delivery Program -20 °C to +80 °C, minimum bending radius 12,5 x d with < 10 m travel distance, minimum bending radius 15 x d with ≥ 10 m travel distance -40 °C to +80 °C, minimum bending radius 5 x d

v max. 2 m/s, 1 m/s unsupported/gliding a max. 20 m/s2 Travel distance

● ● ● ● ●

for high load requirements almost unlimited resistance to oil indoor and outdoor applications with average sun radiation especially for freely suspended and gliding travel distances up to 50 m Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling, refrigerating sector

Delivery program Part No. CFTHERMO.J.001 CFTHERMO.K.001 CFTHERMO.K.002 CFTHERMO.T.002

Number of cores and conductor nominal cross section [mm2] (2x0,23)C (2x0,23)C (2x0,23)C+3G0,5 (2x0,23)C+3G0,5

External diameter approx. [mm] 5,5 5,5 7,0 7,0

Copper index [kg/km] 8 8 23 23

Weight [kg/km] 35 33 62 62

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Part No.

UV-resistant

Freely suspended and gliding travel distances up to 50 m, Class 2. Medium

CFTHERMO.J.001 CFTHERMO.K.001 CFTHERMO.K.002

Nominal voltage

300/300 V (following DIN VDE 0245)

CFTHERMO.T.002

Testing voltage

1500 V

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

Thermo materials Fe-CuNi NiCr-Ni NiCr-Ni Cu Cu-CuNi Cu

Number of cores and conductor nominal cross section [mm2] (2x0,23)C (2x0,23)C (2x0,23)C 3G0,5 (2x0,23)C 3G0,5

Colour code

Jacketcolour

+ black, - white + green, - white + green, - white brown, blue, yellow-green + brown, - white brown, blue, yellow-green

black green green brown

Order example: CFTHERMO.K.001 – in your desired length (0,5 m steps) CFTHERMO chainflex series K.001 Code Thermocouple-type ®

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Please use www.chainflex.eu/en/CFTHERMO for your online order. Delivery time 24h or today.

Image exemplary.

Delivery time means time until shipping of goods.

eplan download, configurator

www.igus.eu/en/CFTHERMO

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

257


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:03 Seite 258

CFTHERMO PUR 12,5 - 15 x d

CFTHERMO PUR 12,5 - 15 x d

PUR Thermocouple cable CFTHERMO ● ● ● ● ● ● ●

for high load requirements PUR outer jacket oil-resistant and coolant-resistant notch-resistant PVC-free/halogen-free flame-retardant hydrolysis-resistant and microbe-resistant

New!

Delivery program thermocouple cable, harnessed (PUR) – Standard connector Jacket

®

igus

Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø

Bending

mm

radius

Delivery program thermocouple cable, harnessed (PUR) – Miniature connector Jacket

Standard connector Type J Pre-assembled at one end PUR

MAT9850021

MAT9850022

(2x0,23)C

5,5

12,5

New*

MAT9850023

(2x0,23)C

5,5

12,5

New*

MAT9850031

(2x0,23)C

5,5

12,5

New*

MAT9850032

(2x0,23)C

5,5

12,5

New*

MAT9850033

PUR

MAT9850001

(2x0,23)C

5,5

12,5

New*

PUR

MAT9850002

(2x0,23)C

5,5

12,5

New*

PUR

MAT9850003

(2x0,23)C

5,5

12,5

New*

PUR

MAT9850011

(2x0,23)C

5,5

12,5

New*

(2x0,23)C

5,5

12,5

New*

(2x0,23)C

5,5

12,5

New*

Miniature connector Type K Pre-assembled at one end (2x0,23)C

5,5

12,5

New*

Standard connector Type K Pre-assembled on both sides PUR

radius

Miniature connector Type K Pre-assembled at one end

Standard connector Type K Pre-assembled at one end PUR

Bending

mm

Miniature connector Type J Pre-assembled on both sides

Standard connector Type K Pre-assembled at one end PUR

ø

nominal cross section [mm2]

Miniature connector Type J Pre-assembled at one end

Standard connector Type J Pre-assembled on both sides PUR

Number of cores and conductor

Part No.

Miniature connector Type J Pre-assembled at one end

Standard connector Type J Pre-assembled at one end PUR

igus®

PUR

MAT9850012

Miniature connector Type K Pre-assembled on both sides (2x0,23)C

5,5

12,5

New*

PUR

MAT9850013

eplan download, configurator www.igus.eu/en/CFTHERMO Technical information Page 257 Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core Image exemplary. * New in this catalog.

950 types from stock no cutting costs ... 258

(for up to 10 cuts of the same type)

Technical information Page 257 Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core Image exemplary. * New in this catalog.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

259


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:03 Seite 260

TPE Power cable CFFLAT ● ● ● ● ● ● ●

Class 7.4.4 (7 maximum load requirements

for maximum load requirements TPE outer jacket oil-resistant biooil-resistant PVC-free/halogen-free UV-resistant hydrolysis-resistant and microbe-resistant

Conductor

4 travel distance up to 400 m and more 4 oil-resistant)

CFFLAT TPE 5xd

Typical application area ● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m and more Storage and retrieval units for high-bay warehouses, tight design space, small radii, machining units/machine tools, quick handling, clean room, semiconductor insertion, low-temperature applications

Highly flexible braided special conductor

Core insulation

Mechanically high-quality TPE mixture.

Outer jacket

T/R moved

Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Steel blue (similar to RAL 5011) -35 °C to +90 °C, minimum bending radius 5 x d

T/R fixed

-40 °C to +90 °C, minimum bending radius 4 x d

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] 1x2,5 1x4,0

CFFLAT.25.01 CFFLAT.40.01

External diameter approx. [mm] 13,5 x 5,0 14,0 x 5,0

Copper index [kg/km] 30 46

Weight [kg/km] 71 109

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. x = without earth core G = with green-yellow earth core

Order example: CFFLAT.25.01 – in your desired length (0,5 m steps) CFFLAT chainflex series .25 Code nominal cross section .01 Number of cores ®

Please use www.chainflex.eu/en/CFFLAT for your online order.

v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2

Delivery time 24h or today. Delivery time means time until shipping of goods.

Travel distance UV-resistant

Freely suspended and gliding travel distances up to 400 m and more, Class 4 High

Nominal voltage

600/1000 V (following DIN VDE 0250).

Testing voltage

4000 V (following DIN VDE 0281-2).

Oil

Halogen-free

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

Silicon-free

Image exemplary.

CFFLAT TPE 5xd

eplan download, configurator

www.igus.eu/en/CFFLAT

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

261


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:03 Seite 262

CFBRAID TPE 10 x d

TPE Power cable CFBRAID ● ● ● ● ● ● ●

Class 6.4.4 (6 maximum load requirements

for maximum load requirements TPE outer jacket unshielded/shielded oil-resistant, biooil-resistant flame-retardant UV-resistant hydrolysis-resistant and microbe-resistant

Conductor Core insulation Core stranding

Silicon-free

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture (following DIN VDE 0207 Part 4). Cores braided together using a special technique.

4 travel distance up to 400 m and more 4 oil-resistant)

CFBRAID TPE 10 x d

CEI

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following CEI 20-35

CE

Following 2006/95/EG

DESINA

According to VDW, DESINA standardisation

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, tested by IPA according to standard 14644-1

Typical application area Core identification Inner jacket

Cores black with white numerals, one core green-yellow

T/R moved

TPE mixture adapted to suit the requirements in energy chains® (for shielded types). Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical (for shielded types). Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Jet black (similar to RAL 9005) -35 °C to +70 °C, minimum bending radius 7,5 x d

T/R fixed

-40 °C to +70 °C, minimum bending radius 4 x d

Overall shield

Outer jacket

v max. 10 m/s, 6 m/s unsupported/gliding a max. 80 m/s2

for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for gliding travel distances up to 400 m and more Storage and retrieval units for high-bay warehouses, quick handling, in- and outdoor cranes, low-temperature applications especially for applications with corksrew-risk

What is special about CF.BRAID? Due to their unique type of design and especially in the case of cross-sections ≥ 2.5 mm² and long distances of travel with large numbers of cycles, cables with 7 cores have an increased tendency toward the formation of corkscrews. Due to the special design of the CF.BRAID with 8 braided cores, corkscrews can be completely ruled out.

Delivery program Part No.

Travel distance

Gliding travel distances up to 400 m and more, Class 4

UV-resistant

High

Nominal voltage

600/1000 V (following DIN VDE 0250).

Testing voltage

4000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Flame-retardant

● ● ● ● ●

CFBRAID.25.08 CFBRAID.25.08.C(8)

Number of cores and conductor nominal cross section [mm2] 8 G 2,5 (8 G 2,5)C

External diameter approx. [mm] 20,0 23,5

Copper index [kg/km] 192 320

Weight [kg/km] 398 625

(8) without DESINA Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CFBRAID.25.08 – in your desired length (0,5 m steps) CFBRAID chainflex series .25 Code nominal cross section .08 Number of cores ®

Please use www.chainflex.eu/en/CFBRAID for your online order. Delivery time 24h or today.

Image exemplary.

Delivery time means time until shipping of goods.

eplan download, configurator

www.igus.eu/en/CFBRAID

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

263


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:03 Seite 264

CFSP182

Cables for hanging applications CFSPECIAL

Delivery program Part No.

Jacket

Number of cores and conductor nominal cross section [mm2]

External diameter approx. [mm]

Copper index [kg/km]

Weight [kg/km]

33

135

CFSP414

Cables for rail vehicles CFSPECIAL Delivery program Part No.

Number of cores and conductor nominal cross section [mm2]

External diameter approx. [mm]

Copper index [kg/km]

4,5 5,5 6,6 5,0 6,0 7,0

29 40 53 34 47 62

Weight [kg/km]

Profibus CFSPECIAL.182.001 PUR

(2x0,25)C

10,0

New**

Ethernet/CAT5/GigE CFSPECIAL.182.045 PUR

(4x2x0,15)C

9,5

43

132

New**

Colour code

Data sheet download

red, green www.igus.eu/en/CFSP1 white-blue/blue, white-orange/orange, www.igus.eu/en/CFSP1 white-green/green, white-brown/brown

Order example: CFSPECIAL.182.001 – in your desired length (0,5 m steps) CFSPECIAL chainflex series .182 igus key .001 Code Bus type ®

4x0,25 6x0,25 8x0,25 4x0,34 6x0,34 8x0,34

12 18 24 16 24 33

New* New* New* New* New* New*

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalogue.

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. x = without earth core G = with green-yellow earth core * New in this catalogue.

Delivery Characteristic Core group program wave impedance Part No. approx. [Ω] CFSPECIAL.182.001 150 (2x0,25)C CFSPECIAL.182.045 100 (4x2x0,15)C

CFSPECIAL.414.02.04(1) CFSPECIAL.414.02.06(1) CFSPECIAL.414.02.08(1) CFSPECIAL.414.03.04 CFSPECIAL.414.03.06(1) CFSPECIAL.414.03.08(1)

Delivery program Part No. CFSPECIAL.414.02.04 CFSPECIAL.414.02.06 CFSPECIAL.414.02.08 CFSPECIAL.414.03.04 CFSPECIAL.414.03.06 CFSPECIAL.414.03.08

Core group

Colour code

4 x 0,25 6 x 0,25 8 x 0,25 4 x 0,34 6 x 0,34 8 x 0,34

brown, blue, black, white according to DIN 47100 according to DIN 47100 brown, blue, black, white according to DIN 47100 according to DIN 47100

Data sheet download www.igus.eu/en/CFSP4 www.igus.eu/en/CFSP4 www.igus.eu/en/CFSP4 www.igus.eu/en/CFSP4 www.igus.eu/en/CFSP4 www.igus.eu/en/CFSP4

®

Please use www.chainflex.eu/en/CFSP1 for your online order. Order example: CFSPECIAL.414.03.04 – in your desired length (0,5 m steps) CFSPECIAL chainflex series .414 igus key .03 Code nominal cross section .04 Number of cores ®

Delivery time 24h or today.

®

Please use www.chainflex.eu/en/CFSP1 for your online order.

Delivery time means time until shipping of goods.

Delivery time 24h or today. Typical application area

Delivery time means time until shipping of goods.

● for hanging applications up to 50 m ● for increased tensile load ● Storage and retrieval units for high-bay warehouses, hanging control elements, lift

Toxicity

According to EN 50306-9-2

Low smoke gas density

According to DIN EN 61034-2

Typical application area ● Rail vehicle , Automatic doors , buses, adjusting equipment, storage and retrieval units for high-bay warehouses, hanging control elements, lift

eplan download, configurator www.igus.eu/en/CFSP1

eplan download, configurator www.igus.eu/en/CFSP4

950 types from stock no cutting costs ... 264

(for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

265


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:03 Seite 266

chainflex readycable Cable type

Video-/vision-/bus technology

Camera

Video-/vision-/bus technology (with camera reference list

Jacket Page

Page 288)

FireWire

Ready-made cable

TPE

268

USB

Ready-made cable

TPE

272

GigE

Ready-made cable

TPE

276

FOC

Ready-made cable

PUR

278

FOC

Ready-made cable (Robotics)

TPE

282

Coax

Ready-made cable

TPE

284

267


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:03 Seite 268

TPE Bus cable FireWire

CFBUS

● ● ● ● ● ● ●

Class 6.4.4 (6 maximum load requirements

FireWire cable (IEEE 1394a) for maximum load requirements TPE outer jacket oil-resistant bio-oil-resistant flame-retardant hydrolysis-resistant and microbe-resistant

Conductor Core insulation Core identification Core stranding Element shield

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality PE mixture. Core 0,15 mm2: orange/blue, green/red. Core 0,34 mm2: black, white. Cores and paires stranded with an especially short pitch length.

T/R moved

Extremely flexible, tinned copper shield over foil taping. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Red lilac (similar to RAL 4001) -35 °C to +70 °C, minimum bending radius 12,5 x d

T/R fixed

-40 °C to +70 °C, minimum bending radius 5 x d

Outer jacket

4 travel distance up to 400 m 4 oil-resistant)

Camera FireWire TPE

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

DESINA

According to VDW, DESINA standardisation

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, tested by IPA according to standard 14644-1

CFBUS

Camera FireWire TPE

Typical application area ● FireWire cable for use in e-chains® in industrial environments (Technical note ● Transmission lengths of up to 10 m

Page 543)

Test data Page 44 or www.igus.eu/en/test9 Camera reference list Page 288

v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2 Travel distance UV-resistant

Freely suspended and gliding travel distances up to 400 m, Class 4 Medium

Nominal voltage

30 V

Testing voltage

500 V

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Flame-retardant Silicon-free

Image exemplary.

UL/CSA

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Style 1589 and 21371, 30 V, 80 °C

eplan download, configurator

www.igus.eu/en/Vision

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

More than 6.0 million movements have been successfully tested with the CFBUS.055 in e-chains® with 10 m cable length.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

269


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:03 Seite 270

Camera FireWire TPE

TPE Bus cable FireWire FireWire cable (IEEE 1394a) for maximum load requirements TPE outer jacket oil-resistant bio-oil-resistant flame-retardant hydrolysis-resistant and microbe-resistant Delivery program FireWire (TPE)

Delivery program Part No.

®

12,5 x d

Delivery program FireWire (TPE)

igus

Number of cores and

External

Copper

Weight

Delivery program

Part No.

conductor nominal cross

diameter

index

[kg/km]

Part No.

section [mm2]

approx. [mm]

[kg/km]

Pre-assembled on both sides Socket A/Socket A CFBUS.055

MAT9048160 ((2x(2x0,15)C+2x(0,34)C)

MAT9048621

2x(2x0,15)C+2x(0,34)C

7,5

42

81

MAT9048623

2x(2x0,15)C+2x(0,34)C

12,5 x d

igus

Number of cores and

External

Copper

Weight

Part No.

conductor nominal cross

diameter

index

[kg/km]

section [mm2]

approx. [mm]

[kg/km]

CFBUS.055

7,5

42

81

7,5

42

81

7,5

42

81

MAT9048624 (2x(2x0,15)C+2x(0,34)C

Pre-assembled on both sides Socket B/Socket B 7,5

42

81

Pre-assembled on both sides Socket A/Socket B CFBUS.055

®

Pre-assembled on both sides Pin A/Pin B

Pre-assembled on both sides Socket A/Pin A CFBUS.055

4 travel distance up to 400 m 4 oil-resistant)

CFBUS

CFBUS

● ● ● ● ● ● ●

Class 6.4.4 (6 maximum load requirements

Camera FireWire TPE

CFBUS.055

MAT9048626 (2x(2x0,15)C+2x(0,34)C

Pre-assembled on both sides Socket B/Pin B 7,5

42

81

CFBUS.055

MAT9048628

2x(2x0,15)C+2x(0,34)C

Connector

Pre-assembled on both sides Socket A/Pin B CFBUS.055

MAT9048625

2x(2x0,15)C+2x(0,34)C

7,5

42

MAT9048627

2x(2x0,15)C+2x(0,34)C

7,5

42

with clip

Socket B (Moulded connector)

without clip

Pin A

(Pin body)

without clip

Pin B

(Moulded connector)

without clip

81

Pre-assembled on both sides Pin B/Pin B CFBUS.055

Socket A (Connector body)

81

Pre-assembled on both sides Pin A/Pin A CFBUS.055

MAT9048620

2x(2x0,15)C+2x(0,34)C

7,5

42

81

7,5

42

81

Pre-assembled on both sides Pin A/Socket B CFBUS.055

MAT9048622

2x(2x0,15)C+2x(0,34)C

eplan download, configurator www.igus.eu/en/Vision

eplan download, configurator www.igus.eu/en/Vision

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. As well available on the roll, in the lengths you require.

950 types from stock no cutting costs ... 270

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. As well available on the roll, in the lengths you require.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

271


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:03 Seite 272

TPE Bus cable USB

CFBUS

● ● ● ● ● ● ●

Class 6.4.4 (6 maximum load requirements

USB cable 2.0 for maximum load requirements TPE outer jacket shielded oil-resistant, bio-oil-resistant flame-retardant hydrolysis-resistant and microbe-resistant

Conductor Core insulation

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality PE mixture.

Core stranding

Cores and paires stranded with an especially short pitch length.

Core identification

T/R moved

Core 0,5 mm2: red, black. Core 0,08 mm2: white, green (CFBUS.065). Core 0,24 mm2: white, green (CFBUS.066). Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Red lilac (similar to RAL 4001) -35 °C to +70 °C, minimum bending radius 12,5 x d

T/R fixed

-40 °C to +70 °C, minimum bending radius 5 x d

Overall shield Outer jacket

4 travel distance up to 400 m 4 oil-resistant)

Camera USB TPE

UL/CSA

Style 1589 and 21371, 30 V, 80 °C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

DESINA

According to VDW, DESINA standardisation

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, tested by IPA according to standard 14644-

CFBUS

Camera USB TPE

Typical application area ● USB 2.0 cable for use in e-chains® in industrial environments (Technical note ● Transmission lengths of up to 6 m (CFBUS.065) ● Transmission lengths of up to 10 m (CFBUS.066)

Camera reference list

Page 543)

Page 288

v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2 Travel distance UV-resistant

Freely suspended and gliding travel distances up to 400 m, Class 4 Medium

Nominal voltage

30 V

Testing voltage

500 V

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Flame-retardant

Image exemplary.

Silicon-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).

eplan download, configurator

www.igus.eu/en/Vision

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

273


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:04 Seite 274

Camera USB TPE

TPE Bus cable USB USB cable 2.0 for maximum load requirements TPE outer jacket shielded oil-resistant, bio-oil-resistant flame-retardant hydrolysis-resistant and microbe-resistant Delivery program USB (TPE)

Delivery program Part No.

®

12,5 x d

Delivery program USB (TPE)

igus

Number of cores and

External

Copper

Weight

Delivery program

Part No.

conductor nominal cross

diameter

index

[kg/km]

Part No.

section [mm2]

approx. [mm]

[kg/km]

Pre-assembled at one end USB Type A/open end of cable

®

12,5 x d

igus

Number of cores and

External

Copper

Weight

Part No.

conductor nominal cross

diameter

index

[kg/km]

section [mm2]

approx. [mm]

[kg/km]

Pre-assembled on both sides USB Type B/B

CFBUS.065

USB9040001

(2x0,5+1x(2x0,08))C

5,0

26

45

CFBUS.065

USB9040030

2x0,5+1x(2x0,08))C

5,0

26

45

CFBUS.066*

USB9040201

(2x0,5+1x(2x0,24))C

6,0

32

56

CFBUS.066*

USB9040230

2x0,5+1x(2x0,24))C

6,0

32

56

Pre-assembled on both sides USB Type A/A

Pre-assembled on both sides USB Type A/B

CFBUS.065

USB9040010

2x0,5+1x(2x0,08))C

5,0

26

45

CFBUS.065

USB9040040

2x0,5+1x(2x0,08))C

5,0

26

45

CFBUS.066*

USB9040210

(2x0,5+1x(2x0,24))C

6,0

32

56

CFBUS.066*

USB9040240

2x0,5+1x(2x0,24))C

6,0

32

56

Pre-assembled at one end USB Type B/open end of cable

Pre-assembled on both sides USB Type A/A (Socket)

CFBUS.065

USB9040020

2x0,5+1x(2x0,08))C

5,0

26

45

CFBUS.065

USB9040060

2x0,5+1x(2x0,08))C

5,0

26

45

CFBUS.066*

USB9040220

2x0,5+1x(2x0,24))C

6,0

32

56

CFBUS.066*

USB9040260

2x0,5+1x(2x0,24))C

6,0

32

56

Connector

USB Type

A

Connector

B

A (Socket)

eplan download, configurator www.igus.eu/en/Vision

USB Type

A

B

A (Socket)

eplan download, configurator www.igus.eu/en/Vision

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. As well available on the roll, in the lengths you require.

950 types from stock no cutting costs ... 274

4 travel distance up to 400 m 4 oil-resistant)

CFBUS

CFBUS

● ● ● ● ● ● ●

Class 6.4.4 (6 maximum load requirements

Camera USB TPE

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. As well available on the roll, in the lengths you require. * CFBUS.066 wird mit Formschrumpfschlauch über USB-Gehäuse geliefert.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

275


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:04 Seite 276

TPE Bus cable GigE

CFBUS

● ● ● ● ● ● ●

Class 6.4.4 (6 maximum load requirements

GigE cable for maximum load requirements Ethernet special cable for maximum load requirements TPE outer jacket oil-resistant flame-retardant hydrolysis-resistant and microbe-resistant Conductor Core insulation

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality PE mixture.

4 travel distance up to 400 m 4 oil-resistant)

Camera GigE TPE

CEI

Following CEI 20-35

CE

Following 2006/95/EG

DESINA

According to VDW, DESINA standardisation

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, tested by IPA according to standard 14644-

CFBUS

Camera GigE TPE

Typical application area Core stranding Core identification

2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Colour code in accordance with DIN 47100

● Ethernet cable for use in e-chains® in industrial environments (Technical note ● Transmission lengths of up to 50 m

Inner jacket

TPE mixture adapted to suit the requirements in energy chains®.

Camera reference list

Overall shield

T/R moved

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Red lilac (similar to RAL 4001) -35 °C to +70 °C, minimum bending radius 12,5 x d

T/R fixed

-40 °C to +70 °C, minimum bending radius 7,5 x d

Outer jacket

Delivery program GigE (TPE) Part No.

UV-resistant Nominal voltage

30 V

Testing voltage

500 V

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Image exemplary.

NFPA

External

Copper

Weight

diameter

index

[kg/km]

section [mm2]

approx. [mm]

[kg/km]

(4x(2x0,15))C

8,0

35

79

(4x(2x0,15))C

8,0

35

79

(4x(2x0,14)C)

8,5

35

65

(4x(2x0,14)C)

8,5

35

65

GIG9040002

Pre-assembled on both sides RJ45 metal/RJ45 metal CFROBOT8.045*

GIG9045001

Pre-assembled on both sides RJ45 metal/RJ45 plastic CFROBOT8.045*

UL/CSA

Number of cores and conductor nominal cross

GIG9040001

CFBUS.044

Freely suspended and gliding travel distances up to 400 m, Class 4 Medium

Silicon-free

igus

Part No.

Pre-assembled on both sides RJ45 metal/RJ45 plastic

v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2

Flame-retardant

12,5 x d

Pre-assembled on both sides RJ45 metal/RJ45 metal CFBUS.044

Travel distance

Page 288

®

Delivery program

Page 543)

GIG9045002

Connector

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Style 1589 and 21371, 30 V, 80 °C Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

RJ45

metal

8 poles

RJ45

plastic

8 poles, knurled screws

eplan download, configurator www.igus.eu/en/Vision Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. As well available on the roll, in the lengths you require. * Bitte lesen Sie die Produktbeschreibung zur tordierbaren CFROBOT8.045

Page 248

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

277


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:05 Seite 278

PUR Fibre optic cable (FOC) Glass fibre

CFLG.2H

● ● ● ● ● ●

Gradient glass fibre cable 50/125 µm, 62,5/125 µm for high load requirements PUR outer jacket metal-free oil-resistant and coolant-resistant UV-resistant

Class 6.3.3 (6 maximum load requirements

3 travel distance up to 100 m 3 oil-resistant)

Camera FOC PUR

Typical application area ● Fibre optic cable for use in e-chains® in industrial environments ● Transmission lengths of up to 500 m CFLG.2H

Camera FOC PUR

Test data Page 44 or www.igus.eu/en/test9 Camera reference list Page 288 Fibre cable

50/125 µm, 62,5/125 µm fibres in gel-filled hollow cores.

Core stranding

Hollow cores with integrated FOC-fibres stranded with two strain

Core identification

Cores black with white numerals.

Outer jacket

T/R moved

Low-adhesion mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Jet black (similar to RAL 9005) -20 °C to +60 °C, minimum bending radius 12,5 x d

T/R fixed

-25 °C to +60 °C, minimum bending radius 7,5 x d

v max. 10 m/s, 6 m/s unsupported/gliding a max. 20 m/s2

Image exemplary.

Travel distance UV-resistant

Freely suspended and gliding travel distances up to 100 m, Class 3 High

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

Offshore

MUD-resistant following NEK 606 – status 2009.

Silicon-free CE

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

eplan download, configurator

www.igus.eu/en/Vision

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Harnessed igus® E6 system on a camera application.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

279


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:05 Seite 280

PUR Fibre optic cable (FOC) Glass fibre

CFLG.2H

● ● ● ● ●

Class 6.3.3 (6 maximum load requirements

3 travel distance up to 100 m 3 oil-resistant)

Delivery program FOC (PUR)

FOC patch cables for static installation*

Gradient glass fibre cable 50/125 µm, 62,5/125 µm for high load requirements PUR outer jacket metal-free oil-resistant and coolant-resistant, UV-resistant Delivery program FOC (PUR)

Delivery program Part No.

®

igus

Number of fibres

Part No.

2 Fibres

Fibre

ø

Bending

diameter

[mm]

radius

Delivery program Part No.

®

igus

2 Fibres

Number of fibres

Part No.

[µm]

CFLG.2HG.MF.50/125

LWL90412393

LWL90412394

2

50/125

9,0

12,5 x d

FFLG.2G.50/125

LWL90412395

2

50/125

9,0

12,5 x d

FFLG.2G.50/125

2

50/125

9,0

12,5 x d

FFLG.2G.50/125

2

62,5/125

9,0

12,5 x d

FFLG.2G.62,5/125

2

50/125

6,5

12,5 x d

LWL90412400

2

50/125

6,5

12,5 x d

LWL90412401

2

50/125

6,5

12,5 x d

LWL90412402

2

62,5/125

6,5

12,5 x d

2

62,5/125

6,5

12,5 x d

62,5/125

6,5

12,5 x d

Pre-assembled on both sides Connector ST/ST 2

62,5/125

9,0

12,5 x d

FFLG.2G.62,5/125

Pre-assembled on both sides Connector LC/LC CFLG.2HG.MF.62,5/125 LWL90412398

LWL90412399

Pre-assembled on both sides** Connector ST/LC

Pre-assembled on both sides Connector ST/ST CFLG.2HG.MF.62,5/125 LWL90412397

radius

Pre-assembled on both sides Connector LC/LC

Pre-assembled on both sides** Connector ST/LC CFLG.2HG.MF.62,5/125 LWL90412396

Bending

Pre-assembled on both sides Connector ST/ST

Pre-assembled on both sides Connector LC/LC CFLG.2HG.MF.50/125

ø [mm]

Pre-assembled on both sides** Connector ST/LC

Pre-assembled on both sides Connector ST/ST CFLG.2HG.MF.50/125

Fibre diameter [µm]

Pre-assembled on both sides** Connector ST/LC

LWL90412403

Pre-assembled on both sides Connector LC/LC 2

62,5/125

9,0

12,5 x d

FFLG.2G.62,5/125

LWL90412404

Connector

2

Connector

Connector

ST

LC

Connector

ST

Tube sinking

LC

Tube sinking

Tube sinking

Tube sinking LWL90428935

Closed corrugated tube to feed in Fibre optic cables

LWL90428935

(image shown cut open)

eplan download, configurator www.igus.eu/en/Vision

Closed corrugated tube to feed in Fibre optic cables (image shown cut open)

eplan download, configurator www.igus.eu/en/Vision

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. As well available on the roll, in the lengths you require. ** 2 ST coupling pieces needed to be ordered extra, if used as extension cable (MAT0176314).

950 types from stock no cutting costs ... 280

Camera FOC PUR

CFLG.2H

Camera FOC PUR

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. As well available on the roll, in the lengths you require. * FOC patch cable extensions are for protected installation only. ** 2 ST coupling pieces needed to be ordered extra, if used as extension cable (MAT0176314).

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

281


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:05 Seite 282

TPE Fibre optic cable, twistable CFROBOT5

CFROBOT5

● ● ● ● ● ● ●

for twistable loads TPE outer jacket oil-resistant biooil-resistant UV-resistant low-temperature-flexible hydrolysis-resistant and microbe-resistant

Class 7.1.4 (7 maximum load requirements

Part No.

Core stranding Outer jacket

T/R moved T/R fixed

50/125 µm, 62.5/125 µm special fixed wire elements with aramide strain relief. FOC wires stranded with high-tensile aramide dampers around the GRP central element. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Steel blue (similar to RAL 5011) -20 °C to +60 °C, minimum bending radius twisted 12,5 x d -25 °C to +60 °C, minimum bending radius 7,5 x d

Torsion

CFROBOT5.501

± 180°

ø

Bending

diameter

[mm]

radius

LWL90422491

2

50/125

8,5

12,5 x d

LWL90422492

2

50/125

8,5

12,5 x d

2

50/125

8,5

12,5 x d

2

62,5/125

8,5

12,5 x d

2

62,5/125

8,5

12,5 x d

2

62,5/125

8,5

12,5 x d

Pre-assembled on both sides Connector LC/LC CFROBOT5.501

LWL90422493

Pre-assembled on both sides* Connector ST/LC LWL90422494

10 m/s

Pre-assembled on both sides Connector ST/ST

10 m/s

2

LWL90422495

Robots and movements in the 3D range, Class 1 ± 180 °, with 1 m cable length

Pre-assembled on both sides Connector LC/LC CFROBOT5.500

LWL90422496

Connector

UV-resistant

High

Oil

CE

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

Silicon-free

Part No.

2 Fibres

Fibre

Pre-assembled on both sides Connector ST/ST

CFROBOT5.500

Travel distance

Number of fibres

Pre-assembled on both sides* Connector ST/LC

CFROBOT5.500

v max. twisted a max.

igus®

[µm]

CFROBOT5.501

Fibre cable

1 unsupported 4 oil-resistant)

Delivery program CFROBOT5 (TPE) Delivery program

Camera CFROBOT5 TPE

CFROBOT5

Camera CFROBOT5 TPE

Connector

ST

LC

Tube sinking

Tube sinking LWL90428935

Closed corrugated tube to feed in Fibre optic cables (image shown cut open)

Fibres identification Part No.

Colour code

CFROBOT5.500

orange with white numbers

CFROBOT5.501

blue with white numbers

Image exemplary.

Typical application area ● ● ● ● ●

for maximum load requirements with torsion movements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for robots and movements in the 3D range robots, handling

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

eplan download, configurator www.igus.eu/en/Vision Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. As well available on the roll, in the lengths you require. * Bei Verlegung dieser Leitung als Verlängerung müssen zusätzlich 2 ST-Verbinder (MAT0176314, je 1,92 €) bestellt werden.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

283


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:05 Seite 284

TPE Coax cable CFKoax1

CFKoax1

● ● ● ● ● ●

Class 6.4.4 (6 maximum load requirements

75 Ω coax cable for maximum load requirements TPE outer jacket oil-resistant biooil-resistant UV-resistant hydrolysis-resistant and microbe-resistant

4 travel distance up to 400 m 4 oil-resistant)

Camera CFKoax1 TPE

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1 The coax elements used in cables of the CF Koax1 series are comparable with a HF75-0.3/1.6 according to MIL-C-17/94-RG179 and thus fit in an RG179 plug!

Info

CFKoax1

Camera CFKoax1 TPE

Typical application area Conductor Core insulation

Multi-wire; adapted in single-wire diameter and pitch length to suit the requirements in energy chains®. Special FEP-isolating mixture.

Core stranding

Cores stranded in one layer with especially short pitch length.

Identification

Coaxial elements

Element shield

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. TPE mixture adapted to suit the requirements in energy chains®.

Element jacket Outer jacket

Schedule Delivery Program

T/R moved

Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Steel blue (similar to RAL 5011) -35 °C to +100 °C, minimum bending radius 10 x d

T/R fixed

-40 °C to +100 °C, minimum bending radius 7,5 x d

● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, indoor cranes, low-temperature applications

v max. 10 m/s, 5 m/s unsupported/gliding a max. 100 m/s2 Travel distance UV-resistant

Freely suspended and gliding travel distances up to 400 m, Class 4 High

Nominal voltage

300/300 V (following DIN VDE 0245).

Testing voltage

1500 V

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following 2006/95/EG

Silicon-free

Image exemplary.

CE

eplan download, configurator

www.igus.eu/en/Vision

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Coax cables and other chainflex® cables in platform technology. e-chain®: System E4/4

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

285


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:05 Seite 286

TPE Coax cable CFKoax1

CFKoax1

● ● ● ● ● ●

Delivery program CFKoax1 (TPE) igus®

Number of coaxial

Part No.

elements

1 coaxial element

Delivery program CFKoax1 (TPE)

External

Bending

Copper

Weight

Delivery program

diameter

radius

index

[kg/km]

Part No.

igus®

Number of coaxial

Part No.

elements

approx. [mm]

MAT90423400

MAT90423401

1

4,5

10 x d

9

25

MAT90423402

1

4,5

10 x d

9

25

MAT90423403

1

4,5

10 x d

9

25

MAT90423404

CFKoax1.05

CFKoax1.05

CFKoax1.05

1

4,5

10 x d

9

25

CFKoax1.05

radius

index

[kg/km]

MAT90423405

5

10,0

10 x d

47

135

MAT90423406

5

10,0

10 x d

47

135

MAT90423407

5

10,0

10 x d

47

135

MAT90423408

5

10,0

10 x d

47

135

5

10,0

10 x d

47

135

Pre-assembled at one end Socket/open end of cable 1

4,5

10 x d

9

25

CFKoax1.05

Coaxial elements identification

MAT90423409

Coaxial elements identification

Part No.

Colour code

Part No.

Colour code

CFKoax1.01

red

CFKoax1.05

red, green, blue, white, black

eplan download, configurator www.igus.eu/en/Vision

eplan download, configurator www.igus.eu/en/Vision

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. As well available on the roll, in the lengths you require.

950 types from stock no cutting costs ... 286

diameter

Pre-assembled at one end Connector/open end of cable

Pre-assembled at one end Socket/open end of cable CFKoax1.01

Weight

Pre-assembled on both sides Socket/Socket

Pre-assembled at one end Connector/open end of cable CFKoax1.01

Copper

Pre-assembled on both sides Connector/Connector

Pre-assembled on both sides Socket/Socket CFKoax1.01

Bending

Pre-assembled on both sides Connector/Socket

Pre-assembled on both sides Connector/Connector CFKoax1.01

5 coaxial elements

External approx. [mm]

Pre-assembled on both sides Connector/Socket CFKoax1.01

4 travel distance up to 400 m 4 oil-resistant)

75 Ω coax cable for maximum load requirements TPE outer jacket oil-resistant biooil-resistant UV-resistant hydrolysis-resistant and microbe-resistant

Delivery program Part No.

Class 6.4.4 (6 maximum load requirements

Camera CFKoax1 TPE

CFKoax1

Camera CFKoax1 TPE

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. As well available on the roll, in the lengths you require.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

287


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:05 Seite 288

Camera

Camera reference list Selection chart

Camera

Camera reference list Selection chart

CFBUS.065

CFBUS.066

CFBUS.055

CFLG.2HG

CFBUS.044

CFBUS.065

CFBUS.066

CFBUS.055

CFLG.2HG

CFBUS.044

USB

USB

FireWire

FOC

GigE

USB

USB

FireWire

FOC

GigE

up to 5 m

up to 10 m

up to 10 m

up to 400 m

up to 50 m

up to 5 m

up to 10 m

up to 10 m

up to 400 m

up to 50 m

ALLIED

ALLIED

Guppy F-033B

Pike F-032B Fiber

GB650 / GB650c

GX6600 / GX6600C

Guppy F-033C

Pike F-032C Fiber

GB660 / GB660c

GT660 / GT660C

Guppy F-036B

Pike F-100B Fiber

GB1380 / GB1380c

GT1290 / GT1290C

Guppy F-036C

Pike F-100C Fiber

GB2450 / GB2450c

GT1380 / GT1380C

Guppy F-038B

Pike F-145B Fiber

GC640 / GC640c

GT1600 / GT1600C

Guppy F-038C

Pike F-145C Fiber

GC650 / GC650c

GT1910 / GT1910C

Guppy F-038B NIR

Pike F-210B Fiber

GC655 / GC655c

GT1920 / GT1920C

Guppy F-038C NIR

Pike F-210C Fiber

GC660 / GC660c

GT2300 / GT2300C

Guppy F-044B

Pike F-421B Fiber

GC750 / GC750c

GT2450 / GT2450C

Guppy F-044C

Pike F-421C Fiber

GC780 / GC780C

GT2750 / GT2750C

Guppy F-044B NIR

Pike F-505B Fiber

GC1020 / GC1020c

Manta G-032B/G-032C

Guppy F-044C NIR

Pike F-505C Fiber

GC1280

Manta G-033B/G-033C

Guppy F-046B

Pike F-1100B Fiber

GC1290 / GC1290c

Manta G-046B/G-046C

Guppy F-046C

Pike F-1100C Fiber

GC1350 / GC1350c

Manta G-125B/G-125C

Guppy F-080B

Pike F-1600B Fiber

GC1380 / GC1380c

Manta G-145B/G-145C

Guppy F-080C

Pike F-1600C Fiber

GC1380CH / GC1380H

Manta G-145B/145C 30fps

Guppy F-146B

Stingray F-033B Fiber

GC1600 / GC1600c

Manta G-145B-NIR

Guppy F-146C

Stingray F-033C Fiber

GC1600CH / GC1600H

Manta G-146B/G-146C

Guppy F-503B

Stingray F-046B Fiber

GC2450 / GC2450c

Manta G-201B/G-201C

Guppy F-503C

Stingray F-046C Fiber

GE640 / GE640c

Manta G-504B/G-504C

Marlin F-033B

Stingray F-080B Fiber

GE650 / GE650c

Marlin F-033C

Stingray F-080C Fiber

GE680 / GE680c

Marlin F-046B

Stingray F-125B Fiber

GE1050 / GE1050c

Marlin F-046C

Stingray F-125C Fiber

GE1350 / GE1350c

Marlin F-080B

Stingray F-145B Fiber

GE1380 / GE1380c

Marlin F-080C

Stingray F-145C Fiber

GE1600 / GE1600c

Marlin F-080B 30fps

Stingray F-146B Fiber

GE1650 / GE1650c

Marlin F-080C 30fps

Stingray F-146C Fiber

GE1660 / GE1660c

Marlin F-131B

Stingray F-201B Fiber

GE1900 / GE1900c

Marlin F-131C

Stingray F-201C Fiber

GE1910 / GE1910c

Marlin F-131B NIR

Stingray F-504B Fiber

GE2040 / GE2040c

Marlin F-145B2

Stingray F-504C Fiber

GE4000 / GE4000c

Marlin F-145C2

GE4900 / GE4900c

Marlin F-146B

GS650 / GS650c

Marlin F-146C

GS660 / GS660c

Marlin F-201B

GS1380 / GS1380c

Marlin F-201C

GS2450 / GS2450c

Oscar F-320C

GX1050 / GX1050C

Oscar F-510C

GX1660 / GX1660C

Oscar F-810C

GX1910 / GX1910C GX1920 / GX1920C GX2300 / GX2300C GX2750 / GX2750C GX3300 / GX3300C

950 types from stock no cutting costs ... 288

(for up to 10 cuts of the same type)

... no minimum order quantity ... igus速 GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

289


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:06 Seite 290

Camera

Camera reference list Selection chart CFBUS.065

CFBUS.066

CFBUS.055

CFLG.2HG

CFBUS.044

CFBUS.065

CFBUS.066

CFBUS.055

CFLG.2HG

CFBUS.044

USB

USB

FireWire

FOC

GigE

USB

USB

FireWire

FOC

GigE

up to 5 m

up to 10 m

up to 10 m

up to 400 m

up to 50 m

up to 5 m

up to 10 m

up to 10 m

up to 400 m

up to 50 m

ARTRAY

BASLER

ARTCAM-...

ARTCAM-...

A102f

piA640-210gm/gc

640-THERMO

640-THERMO

A102fc

piA1000-48gm/gc

320-THERMO

320-THERMO

A311f

piA1600-35gm/gc

150P4-HDMI

150P4-HDMI

A311fc

piA1900-32gm/gc

150P4-HDMI-BW

150P4-HDMI-BW

A312f

piA2400-12gm/gc

130MI-HDMI

130MI-HDMI

A312fc

ruL1024-19gm

130MI-HDMI-BW

130MI-HDMI-BW

A601f

ruL1024-36gm

150P4-MOUT-DUAL

150P4-MOUT-DUAL

A601fc

ruL1024-57gm

150P4-MOUT-DUAL-BW

150P4-MOUT-DUAL-BW

A631f

ruL2048-10gm

130MI-MOUT-DUAL

130MI-MOUT-DUAL

A631fc

ruL2048-19gm

130MI-MOUT-DUAL-BW

130MI-MOUT-DUAL-BW

A641f

ruL2048-30gm

625KY

625KY

A641fc

ruL2098-10gc

ARTCAM-...

ARTCAM-...

scA640-70gm/gc

625KY-BW

625KY-BW

scA640-74gm/gc

500P II

500P II

scA750-60gm/gc

274KY

274KY

scA780-54gm/gc

274KY-BW

274KY-BW

scA1000-20gm/gc

150P III

150P III

scA1000-30gm/gc

150P III -BW

150P III -BW

scA1390-17gm/gc

445KY

445KY

scA1400-17gm/gc

445KY-BW

445KY-BW

scA1400-30gm/gc

098 II

098 II

scA1600-14gm/gc

098 II -BW

098 II -BW

scA1600-14gm/gc

900MI

900MI

500MI

500MI

500MI-BW

500MI-BW

FWX03

300MI

300MI

FWX03c

TXGC03c

130MI

130MI

FWX05c-II

TXG03 [-P]

130MI-BW

130MI-BW

FWX05-II

TXG03c [-P]

036MI

036MI

FWX06

TXG04 [-P]

036MI-BW

036MI-BW

FWX06c

TXG04c [-P]

900SS

900SS

FWX08

TXG06 [-P]

500SS

500SS

FWX08c

TXG06c [-P]

500SS-BW

500SS-BW

FWX131

TXG08 [-P]

300SS

300SS

FWX131c

TXG08c [-P]

130SS

130SS

FWX14

TXG13 [-P]

130SS-BW

130SS-BW

FWX14c

TXG13c [-P]

036SS

036SS

FWX20

TXG14 [-P]

036SS-BW

036SS-BW

FWX20c

TXG14c [-P]

022MINI

022MINI

FWXC03c

TXG14f [-P]

022MINI-BW

022MINI-BW

FWXC13c

TXG14cf [-P]

FWXC30c

TXG20 [-P]

BAUMER

950 types from stock no cutting costs ... 290

Camera

Camera reference list Selection chart

(for up to 10 cuts of the same type)

TXGC03

FWL120

TXG20c [-P]

FQX50c

TXG50 [-P]

FQX80c

TXG50c [-P]

... no minimum order quantity ... igus速 GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

291


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:06 Seite 292

Camera

Camera reference list Selection chart

Camera

Camera reference list Selection chart

CFBUS.065

CFBUS.066

CFBUS.055

CFLG.2HG

CFBUS.044

CFBUS.065

CFBUS.066

CFBUS.055

CFLG.2HG

CFBUS.044

USB

USB

FireWire

FOC

GigE

USB

USB

FireWire

FOC

GigE

up to 5 m

up to 10 m

up to 10 m

up to 400 m

up to 50 m

up to 5 m

up to 10 m

up to 10 m

up to 400 m

up to 50 m

THE IMAGING SOURCE

iDS UI-1220-M/C

UI-5220SE-M/C

DMK 21AU04

DMK 21AU04

UI-1540-M

UI-5540SE-M

DFK 21AU04

DFK 21AU04

DFK 21F04

UI-1640-C

UI-5640SE-C

DBK 21AU04

DBK 21AU04

DMK 21AF04

UI-1550-C

UI-5550SE-C

DMK 31AU03

DMK 31AU03

DFK 21AF04

UI-1460-C

UI-5460SE-C

DFK 31AU03

DFK 31AU03

DBK 21AF04

UI-1480-M/C

UI-5480SE-M/C

DBK 31AU03

DBK 31AU03

DMK 31AF03

UI-2210-M/C

UI-6210SE-M/C

DMK 41AU02

DMK 41AU02

DFK 31AF03

UI-2410-M/C

UI-6410SE-M/C

DFK 41AU02

DFK 41AU02

DBK 31AF03

UI-2220-M/C

UI-6220SE-M/C

DBK 41AU02

DBK 41AU02

DMK 41AF02

UI-2230-M/C

UI-6230SE-M/C

DMK 21BU04

DMK 21BU04

DFK 41AF02

UI-2240-M/C

UI-6240SE-M/C

DFK 21BU04

DFK 21BU04

DBK 41AF02

UI-2250-M/C

UI-6250SE-M/C

DBK 21BU04

DBK 21BU04

DMK 21BF04 DFK 21BF04

DMK 21F04

UI-1220RE-M/C

UI-1220RE-M/C

UI-5220HE-M/C

DMK 31BU03

DMK 31BU03

UI-1540RE-M

UI-1540RE-M

UI-5540HE-M

DFK 31BU03

DFK 31BU03

DBK 21BF04

UI-1640RE-C

UI-1640RE-C

UI-5640HE-C

DBK 31BU03

DBK 31BU03

DMK 31BF03

UI-1550RE-C

UI-1550RE-C

UI-5550HE-C

DMK 41BU02

DMK 41BU02

DFK 31BF03

UI-1460RE-C

UI-1460RE-C

UI-5460HE-C

DFK 41BU02

DFK 41BU02

DBK 31BF03

UI-1480RE-M/C

UI-1480RE-M/C

UI-5480HE-M/C

DBK 41BU02

DBK 41BU02

DMK 41BF02

UI-2210RE-M/C

UI-2210RE-M/C

UI-6210HE-M/C

DMK 21BU04.H

DMK 21BU04.H

DFK 41BF02

UI-2410RE-M/C

UI-2410RE-M/C

UI-6410HE-M/C

DFK 21BU04.H

DFK 21BU04.H

DBK 41BF02

UI-2220RE-M/C

UI-2220RE-M/C

UI-6220HE-M/C

DBK 21BU04.H

DBK 21BU04.H

DMK 21BF04.H

UI-2230RE-M/C

UI-2230RE-M/C

UI-6230HE-M/C

DMK 31BU03.H

DMK 31BU03.H

DFK 21BF04.H

UI-2240RE-M/C

UI-2240RE-M/C

UI-6240HE-M/C

DFK 31BU03.H

DFK 31BU03.H

DBK 21BF04.H

UI-2250RE-M/C

UI-2250RE-M/C

UI-6250HE-M/C

DBK 31BU03.H

DBK 31BU03.H

DMK 31BF03.H

DMK 41BU02.H

DMK 41BU02.H

DFK 31BF03.H

DFK 41BU02.H

DFK 41BU02.H

DBK 31BF03.H

DBK 41BU02.H

DBK 41BU02.H

DMK 41BF02.H DFK 41BF02.H DBK 41BF02.H DMK 21AF04-Z DFK 21AF04-Z DBK 21AF04-Z DMK 31AF03-Z DFK 31AF03-Z DBK 31AF03-Z DMK 21BF04-Z DFK 21BF04-Z DBK 21BF04-Z DMK 31BF03-Z DFK 31BF03-Z DBK 31BF03-Z DMK 21BF04-Z.H DFK 21BF04-Z.H DBK 21BF04-Z.H DMK 31BF03-Z.H DFK 31BF03-Z.H DBK 31BF03-Z.H

950 types from stock no cutting costs ... 292

(for up to 10 cuts of the same type)

... no minimum order quantity ... igus速 GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

293


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:06 Seite 294

chainflex readycable Cable type

Jacket

Page

Network

Network-/Ethernet-/FOC-cable/Fieldbus

Network-/Ethernet-/FOC-cable/Fieldbus CFLG.6G

Gradient fibre glass cable, ready-made

TPE

296

CFLG.12G

Gradient fibre glass cable, ready-made

TPE

298

CAT5

Ethernet cable, ready-made

PVC/PUR/TPE

300

CAT5

Ethernet cable, ready-made, L-/T-angle

PVC/PUR/TPE

302

CAT6

Ethernet cable, ready-made

TPE

306

Profibus

Field bus cable, ready-made

PVC/PUR/TPE

308

295


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:06 Seite 296

Network CFLG.6G TPE

TPE Fibre optic cable (FOC) CFLG.6G Gradient glass-fibre cable for maximum load requirements TPE outer jacket halogen-free low-temperature-flexible to -40 °C hydrolysis-resistant and microbe-resistant

Test data

4 travel distance up to 400 m 4 oil-resistant)

Page 42

CFLG.G

● ● ● ● ●

Class 7.4.4 (7 maximum load requirements

Network CFLG.6G TPE

Fibre cable

Delivery program (TPE)

50/125 µm, 62,5/125 µm fibres in gel-filled hollow cores. Delivery program

Stranding Identification Outer jacket

T/R moved T/R fixed

Stranded GRP rods with integrated torsion protection braid in the outer jacket over gel-filled fibre sheath. Fibres Schedule Delivery Program Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Jet black (similar to RAL 9005) -40 °C to +60 °C, minimum bending radius 15 x d

Number of fibres

Part No.

6 Fibres

Fibre

ø

Bending

diameter

[mm]

radius

[µm]

On both ends BFOC(ST) connectors

LWL9040030

6

50/125

11,5

15 x d

incl. conversion to SC

LWL9040031

6

50/125

11,5

15 x d

incl. conversion to LC

LWL9040032

6

50/125

11,5

15 x d

LWL9040045

6

62,5/125

11,5

15 x d

incl. conversion to SC

LWL9040046

6

62,5/125

11,5

15 x d

incl. conversion to LC

LWL9040047

6

62,5/125

11,5

15 x d

-40 °C to +60 °C, minimum bending radius 8,5 x d

v max. 10 m/s, 6 m/s unsupported/gliding a max. 20 m/s2

igus®

Tube sinking

Tube sinking Travel distance UV-resistant Oil

Freely suspended and gliding travel distances up to 500 m and more, Class 4 High

Halogen-free

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Silicon-free

LWL90428936

Closed corrugated tube to feed in Fibre optic cables (image shown cut open)

Fibres identification Part No.

Fibres identification

Identification hollow cores

CFLG.6G.62,5/125.TC

ecru, yellow, green, red, violet, blue

orange

CFLG.6G.50/125.TC

ecru, yellow, green, red, violet, blue

blue

Image exemplary.

Typical application area ● ● ● ● ● ●

for maximum load requirements maximum EMC protection, with high transmission qualities in terms of glass-specific requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications only for freely suspended and gliding travel distances up to 500 m and more Outdoor ship to shore, crane applications, conveyer technology, low-temperature applications

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

eplan download, configurator www.igus.eu/en/CFLGGT Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

297


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:06 Seite 298

Network CFLG.12G TPE

TPE Fibre optic cable (FOC) CFLG.12G Gradient glass-fibre cable for maximum load requirements TPE outer jacket halogen-free low-temperature-flexible to -40 °C hydrolysis-resistant and microbe-resistant

Test data

4 travel distance up to 400 m 4 oil-resistant)

Page 42

CFLG.G

● ● ● ● ●

Class 7.4.4 (7 maximum load requirements

Network CFLG.12G TPE

Fibre cable

Delivery program (TPE)

50/125 µm, 62,5/125 µm fibres in gel-filled hollow cores. Delivery program

Stranding Identification Outer jacket

T/R moved T/R fixed

Stranded GRP rods with integrated torsion protection braid in the outer jacket over gel-filled fibre sheath. Fibres Schedule Delivery Program Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Jet black (similar to RAL 9005) -40 °C to +60 °C, minimum bending radius 15 x d

Number of fibres

Part No.

12 Fibres

Fibre

ø

Bending

diameter

[mm]

radius

[µm]

On both ends BFOC(ST) connectors

LWL9040060

12

50/125

11,5

15 x d

incl. conversion to SC

LWL9040061

12

50/125

11,5

15 x d

incl. conversion to LC

LWL9040062

12

50/125

11,5

15 x d

LWL9040075

12

62,5/125

11,5

15 x d

incl. conversion to SC

LWL9040076

12

62,5/125

11,5

15 x d

incl. conversion to LC

LWL9040077

12

62,5/125

11,5

15 x d

-40 °C to +60 °C, minimum bending radius 8,5 x d

v max. 10 m/s, 6 m/s unsupported/gliding a max. 20 m/s2

igus®

Tube sinking

Tube sinking Travel distance UV-resistant Oil

Freely suspended and gliding travel distances up to 500 m and more, Class 4 High

Halogen-free

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Silicon-free

LWL90428936

Closed corrugated tube to feed in Fibre optic cables (image shown cut open)

Fibres identification Part No.

Fibres identification

Identification hollow cores

CFLG.12G.62,5/125.TC

ecru, yellow, green, red, violet, blue, lightblue

orange

gray, brown, black, orange, pink CFLG.12G.50/125.TC

ecru, yellow, green, red, violet, blue, lightblue

blue

gray, brown, black, orange, pink

Image exemplary.

Typical application area ● ● ● ● ● ●

for maximum load requirements maximum EMC protection, with high transmission qualities in terms of glass-specific requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications only for freely suspended and gliding travel distances up to 500 m and more Outdoor ship to shore, crane applications, conveyer technology, low-temperature applications

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

eplan download, configurator www.igus.eu/en/CFLGGT Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

299


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:06 Seite 300

Network CAT5

Network technique CAT5 cables harnessed ● Technical information PVC Page 136

CFBUS.PVC.045 / CFBUS.PUR.045 / CFROBOT8.045 / CFBUS.044

Network CAT5

● Technical information PUR Page 138

Delivery program Straight (PVC/PUR/PUR-ROBOT/TPE) ®

Jacket

4/8 poles

igus

Number of cores and conductor

ø

Bending

Part No.

nominal cross section [mm2]

mm

radius

CAT5 – 4 poles TPE

● Technical information PUR-ROBOT Page 248

Delivery program Cross-Over (PVC/PUR/PUR-ROBOT/TPE) ®

Jacket

igus

Number of cores and conductor

ø

Bending

Part No.

nominal cross section [mm2]

mm

radius

8 poles

CAT5 – 8 poles

CAT9040001

(2x(2x0,25))C

7,0

12,5 x d

CAT5 – 8 poles PVC

CAT9340020

(4x(2x0,15))C

7,0

12,5 x d

PUR

CAT9240020

(4x(2x0,15))C

7,0

12,5 x d

PUR-ROBOT

CAT9440020

(4x(2x0,15)C)

8,5

10 x d

TPE

CAT9040020

(4x(2x0,15))C

8,0

12,5 x d

CAT5 – 8 poles PVC

CAT9340060

(4x(2x0,15))C

7,0

12,5 x d

PUR

CAT9240060

(4x(2x0,15))C

7,0

12,5 x d

PUR-ROBOT

CAT9440060

(4x(2x0,15)C)

8,5

10 x d

TPE

CAT9040060

(4x(2x0,15))C

8,0

12,5 x d

CAT5 – 8 poles PVC

CAT9340100

(4x(2x0,15))C

7,0

12,5 x d

PUR

CAT9240100

(4x(2x0,15))C

7,0

12,5 x d

PUR-ROBOT

CAT9440100

(4x(2x0,15)C)

8,5

10 x d

TPE

CAT9040100

(4x(2x0,15))C

8,0

12,5 x d

CAT5 – 8 poles PVC

CAT9340140

(4x(2x0,15))C

7,0

12,5 x d

PUR

CAT9240140

(4x(2x0,15))C

7,0

12,5 x d

PUR-ROBOT

CAT9440140

(4x(2x0,15)C)

8,5

10 x d

TPE

CAT9040140

(4x(2x0,15))C

8,0

12,5 x d

CAT5 – 8 poles PVC

CAT9340180

(4x(2x0,15))C

7,0

12,5 x d

PUR

CAT9240180

(4x(2x0,15))C

7,0

12,5 x d

PUR-ROBOT

CAT9440180

(4x(2x0,15)C)

8,5

10 x d

TPE

CAT9040180

(4x(2x0,15))C

8,0

12,5 x d

PVC

CAT9340040

(4x(2x0,15))C

7,0

12,5 x d

PUR

CAT9240040

(4x(2x0,15))C

7,0

12,5 x d

PUR-ROBOT

CAT9440040

(4x(2x0,15)C)

8,5

10 x d

TPE

CAT9040040

(4x(2x0,15))C

8,0

12,5 x d

CAT5 – 8 poles PVC

CAT9340080

(4x(2x0,15))C

7,0

12,5 x d

PUR

CAT9240080

(4x(2x0,15))C

7,0

12,5 x d

PUR-ROBOT

CAT9440080

(4x(2x0,15)C)

8,5

10 x d

TPE

CAT9040080

(4x(2x0,15))C

8,0

12,5 x d

CAT5 – 8 poles PVC

CAT9340120

(4x(2x0,15))C

7,0

12,5 x d

PUR

CAT9240120

(4x(2x0,15))C

7,0

12,5 x d

PUR-ROBOT

CAT9440120

(4x(2x0,15)C)

8,5

10 x d

TPE

CAT9040120

(4x(2x0,15))C

8,0

12,5 x d

CAT5 – 8 poles PVC

CAT9340160

(4x(2x0,15))C

7,0

12,5 x d

PUR

CAT9240160

(4x(2x0,15))C

7,0

12,5 x d

PUR-ROBOT

CAT9440160

(4x(2x0,15)C)

8,5

10 x d

TPE

CAT9040160

(4x(2x0,15))C

8,0

12,5 x d

CAT5 – 8 poles PVC

CAT9340200

(4x(2x0,15))C

7,0

12,5 x d

PUR

CAT9240200

(4x(2x0,15))C

7,0

12,5 x d

PUR-ROBOT

CAT9440200

(4x(2x0,15)C)

8,5

10 x d

TPE

CAT9040200

(4x(2x0,15))C

8,0

12,5 x d

eplan download, configurator Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 300

● Technical information TPE Page 140

(for up to 10 cuts of the same type)

www.igus.eu/en/CAT5

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

301


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:06 Seite 302

Network technique CAT5 cables PVC

Network technique CAT5 cables PUR

● Technical information PVC Page 136

● Technical information PUR Page 138

Connector 1

Connector 2

Connector 3

Connector 4

Connector 5

Connector 1

Connector 2

Connector 3

Connector 4

Connector 5

L-angle curve

L-angle curve

T-angle curve

T-angle curve

straight

L-angle curve

L-angle curve

T-angle curve

T-angle curve

straight

lower

above

outer

inward

lower

above

outer

inward

Delivery program Straight (PVC) Delivery program Part No.

Harnessed with

Number of cores and

ø [mm]

8 poles Bending

connector

conductor nominal cross

combination

section [mm2]

CAT9340380

1

2

(4x(2x0,15))C

7,0

12,5 x d

CAT9340540

1

3

(4x(2x0,15))C

7,0

12,5 x d

CAT9340560

1

4

(4x(2x0,15))C

7,0

CAT9340320

1

5

(4x(2x0,15))C

7,0

CAT9340360

2

1

(4x(2x0,15))C

CAT9340340

2

2

(4x(2x0,15))C

CAT9340500

2

3

CAT9340520

2

4

CAT9340300

2

CAT9340440

3

CAT9340480 CAT9340400

Delivery program Straight (PUR) Delivery program Part No.

Harnessed with

Number of cores and

ø [mm]

8 poles Bending

connector

conductor nominal cross

combination

section [mm2]

CAT9240380

1

2

(4x(2x0,15))C

7,0

12,5 x d

CAT9240540

1

3

(4x(2x0,15))C

7,0

12,5 x d

12,5 x d

CAT9240560

1

4

(4x(2x0,15))C

7,0

12,5 x d

12,5 x d

CAT9240320

1

5

(4x(2x0,15))C

7,0

12,5 x d

7,0

12,5 x d

CAT9240360

2

1

(4x(2x0,15))C

7,0

12,5 x d

7,0

12,5 x d

CAT9240340

2

2

(4x(2x0,15))C

7,0

12,5 x d

(4x(2x0,15))C

7,0

12,5 x d

CAT9240500

2

3

(4x(2x0,15))C

7,0

12,5 x d

(4x(2x0,15))C

7,0

12,5 x d

CAT9240520

2

4

(4x(2x0,15))C

7,0

12,5 x d

5

(4x(2x0,15))C

7,0

12,5 x d

CAT9240300

2

5

(4x(2x0,15))C

7,0

12,5 x d

3

(4x(2x0,15))C

7,0

12,5 x d

CAT9240440

3

3

(4x(2x0,15))C

7,0

12,5 x d

3

4

(4x(2x0,15))C

7,0

12,5 x d

CAT9240480

3

4

(4x(2x0,15))C

7,0

12,5 x d

3

5

(4x(2x0,15))C

7,0

12,5 x d

CAT9240400

3

5

(4x(2x0,15))C

7,0

12,5 x d

CAT9340460

4

4

(4x(2x0,15))C

7,0

12,5 x d

CAT9240460

4

4

(4x(2x0,15))C

7,0

12,5 x d

CAT9340420

4

5

(4x(2x0,15))C

7,0

12,5 x d

CAT9240420

4

5

(4x(2x0,15))C

7,0

12,5 x d

CAT9340390

1

2

(4x(2x0,15))C

7,0

12,5 x d

CAT9240390

1

2

(4x(2x0,15))C

7,0

12,5 x d

CAT9340550

1

3

(4x(2x0,15))C

7,0

12,5 x d

CAT9240550

1

3

(4x(2x0,15))C

7,0

12,5 x d

CAT9340570

1

4

(4x(2x0,15))C

7,0

12,5 x d

CAT9240570

1

4

(4x(2x0,15))C

7,0

12,5 x d

CAT9340330

1

5

(4x(2x0,15))C

7,0

12,5 x d

CAT9240330

1

5

(4x(2x0,15))C

7,0

12,5 x d

CAT9340370

2

1

(4x(2x0,15))C

7,0

12,5 x d

CAT9240370

2

1

(4x(2x0,15))C

7,0

12,5 x d

CAT9340350

2

2

(4x(2x0,15))C

7,0

12,5 x d

CAT9240350

2

2

(4x(2x0,15))C

7,0

12,5 x d

CAT9340510

2

3

(4x(2x0,15))C

7,0

12,5 x d

CAT9240510

2

3

(4x(2x0,15))C

7,0

12,5 x d

CAT9340530

2

4

(4x(2x0,15))C

7,0

12,5 x d

CAT9240530

2

4

(4x(2x0,15))C

7,0

12,5 x d

CAT9340310

2

5

(4x(2x0,15))C

7,0

12,5 x d

CAT9240310

2

5

(4x(2x0,15))C

7,0

12,5 x d

radius

Delivery program Cross-Over (PVC)

8 poles

radius

Delivery program Cross-Over (PUR)

8 poles

CAT9340450

3

3

(4x(2x0,15))C

7,0

12,5 x d

CAT9240450

3

3

(4x(2x0,15))C

7,0

12,5 x d

CAT9340490

3

4

(4x(2x0,15))C

7,0

12,5 x d

CAT9240490

3

4

(4x(2x0,15))C

7,0

12,5 x d

CAT9340410

3

5

(4x(2x0,15))C

7,0

12,5 x d

CAT9240410

3

5

(4x(2x0,15))C

7,0

12,5 x d

CAT9340470

4

4

(4x(2x0,15))C

7,0

12,5 x d

CAT9240470

4

4

(4x(2x0,15))C

7,0

12,5 x d

CAT9340430

4

5

(4x(2x0,15))C

7,0

12,5 x d

CAT9240430

4

5

(4x(2x0,15))C

7,0

12,5 x d

eplan download, configurator www.igus.eu/en/CAT5-LT

eplan download, configurator www.igus.eu/en/CAT5-LT

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 302

Network CAT5 PUR

CFBUS.PUR.045

CFBUS.PVC.045

Network CAT5 PVC

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

303


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:06 Seite 304

Network technique CAT5 cables PUR-ROBOT

Network technique CAT5 cables TPE

● Technical information PUR-ROBOT Page 248

● Technical information TPE Page 140

Connector 1

Connector 2

Connector 3

Connector 4

Connector 5

Connector 1

Connector 2

Connector 3

Connector 4

Connector 5

L-angle curve

L-angle curve

T-angle curve

T-angle curve

straight

L-angle curve

L-angle curve

T-angle curve

T-angle curve

straight

lower

above

outer

inward

lower

above

outer

inward

Delivery program Straight (PUR-ROBOT) Delivery program Part No.

Harnessed with

Number of cores and

ø [mm]

8 poles Bending

connector

conductor nominal cross

combination

section [mm2]

CAT9440380

1

2

(4x(2x0,15)C)

8,5

10 x d

CAT9440540

1

3

(4x(2x0,15)C)

8,5

10 x d

CAT9440560

1

4

(4x(2x0,15)C)

8,5

CAT9440320

1

5

(4x(2x0,15)C)

8,5

CAT9440360

2

1

(4x(2x0,15)C)

CAT9440340

2

2

(4x(2x0,15)C)

CAT9440500

2

3

CAT9440520

2

4

CAT9440300

2

CAT9440440

3

CAT9440480 CAT9440400

Delivery program Straight (TPE) Delivery program Part No.

Harnessed with

Number of cores and

ø [mm]

8 poles Bending

connector

conductor nominal cross

combination

section [mm2]

CAT9040380

1

2

(4x(2x0,15))C

8,0

12,5 x d

CAT9040540

1

3

(4x(2x0,15))C

8,0

12,5 x d

10 x d

CAT9040560

1

4

(4x(2x0,15))C

8,0

12,5 x d

10 x d

CAT9040320

1

5

(4x(2x0,15))C

8,0

12,5 x d

8,5

10 x d

CAT9040360

2

1

(4x(2x0,15))C

8,0

12,5 x d

8,5

10 x d

CAT9040340

2

2

(4x(2x0,15))C

8,0

12,5 x d

(4x(2x0,15)C)

8,5

10 x d

CAT9040500

2

3

(4x(2x0,15))C

8,0

12,5 x d

(4x(2x0,15)C)

8,5

10 x d

CAT9040520

2

4

(4x(2x0,15))C

8,0

12,5 x d

5

(4x(2x0,15)C)

8,5

10 x d

CAT9040300

2

5

(4x(2x0,15))C

8,0

12,5 x d

3

(4x(2x0,15)C)

8,5

10 x d

CAT9040440

3

3

(4x(2x0,15))C

8,0

12,5 x d

3

4

(4x(2x0,15)C)

8,5

10 x d

CAT9040480

3

4

(4x(2x0,15))C

8,0

12,5 x d

3

5

(4x(2x0,15)C)

8,5

10 x d

CAT9040400

3

5

(4x(2x0,15))C

8,0

12,5 x d

CAT9440460

4

4

(4x(2x0,15)C)

8,5

10 x d

CAT9040460

4

4

(4x(2x0,15))C

8,0

12,5 x d

CAT9440420

4

5

(4x(2x0,15)C)

8,5

10 x d

CAT9040420

4

5

(4x(2x0,15))C

8,0

12,5 x d

CAT9440390

1

2

(4x(2x0,15)C)

8,5

10 x d

CAT9040390

1

2

(4x(2x0,15))C

8,0

12,5 x d

CAT9440550

1

3

(4x(2x0,15)C)

8,5

10 x d

CAT9040550

1

3

(4x(2x0,15))C

8,0

12,5 x d

CAT9440570

1

4

(4x(2x0,15)C)

8,5

10 x d

CAT9040570

1

4

(4x(2x0,15))C

8,0

12,5 x d

CAT9440330

1

5

(4x(2x0,15)C)

8,5

10 x d

CAT9040330

1

5

(4x(2x0,15))C

8,0

12,5 x d

CAT9440370

2

1

(4x(2x0,15)C)

8,5

10 x d

CAT9040370

2

1

(4x(2x0,15))C

8,0

12,5 x d

CAT9440350

2

2

(4x(2x0,15)C)

8,5

10 x d

CAT9040350

2

2

(4x(2x0,15))C

8,0

12,5 x d

CAT9440510

2

3

(4x(2x0,15)C)

8,5

10 x d

CAT9040510

2

3

(4x(2x0,15))C

8,0

12,5 x d

CAT9440530

2

4

(4x(2x0,15)C)

8,5

10 x d

CAT9040530

2

4

(4x(2x0,15))C

8,0

12,5 x d

CAT9440310

2

5

(4x(2x0,15)C)

8,5

10 x d

CAT9040310

2

5

(4x(2x0,15))C

8,0

12,5 x d

radius

Delivery program Cross-Over (PUR-ROBOT)

8 poles

radius

Delivery program Cross-Over (TPE)

8 poles

CAT9440450

3

3

(4x(2x0,15)C)

8,5

10 x d

CAT9040450

3

3

(4x(2x0,15))C

8,0

12,5 x d

CAT9440490

3

4

(4x(2x0,15)C)

8,5

10 x d

CAT9040490

3

4

(4x(2x0,15))C

8,0

12,5 x d

CAT9440410

3

5

(4x(2x0,15)C)

8,5

10 x d

CAT9040410

3

5

(4x(2x0,15))C

8,0

12,5 x d

CAT9440470

4

4

(4x(2x0,15)C)

8,5

10 x d

CAT9040470

4

4

(4x(2x0,15))C

8,0

12,5 x d

CAT9440430

4

5

(4x(2x0,15)C)

8,5

10 x d

CAT9040430

4

5

(4x(2x0,15))C

8,0

12,5 x d

eplan download, configurator www.igus.eu/en/CAT5-LT

eplan download, configurator www.igus.eu/en/CAT5-LT

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 304

Network CAT5 TPE

CFBUS.044

CFROBOT8.045

Network CAT5 PUR-ROBOT

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

305


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:06 Seite 306

Network CAT6 TPE

Network CAT6 TPE

CFBUS.050

Network technique CAT6 cables TPE ● Technical information TPE Page 140

Delivery program Straight (TPE) ®

Jacket

8 poles

Delivery program Cross-Over (TPE)

igus

Number of cores and conductor

ø

Bending

Part No.

nominal cross section [mm2]

mm

radius

CAT6 – 8 poles TPE

CAT9040600

(4x(2x0,14)C)C

10,0

12,5 x d

igus

Number of cores and conductor

ø

Bending

Part No.

nominal cross section [mm2]

mm

radius

CAT9040620

(4x(2x0,14)C)C

10,0

12,5 x d

(4x(2x0,14)C)C

10,0

12,5 x d

(4x(2x0,14)C)C

10,0

12,5 x d

Jacket

TPE

CAT6 – 8 poles

CAT9040640

(4x(2x0,14)C)C

10,0

12,5 x d

CAT6 – 8 poles TPE

8 poles

CAT6 – 8 poles

CAT6 – 8 poles TPE

®

TPE

CAT9040660

CAT6 – 8 poles

CAT9040680

(4x(2x0,14)C)C

10,0

12,5 x d

TPE

CAT9040700

eplan download, configurator www.igus.eu/en/CAT5-LT Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 306

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

307


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:07 Seite 308

Network Profibus PVC

Network Profibus PVC

Network technique Profibus cables PVC

CFBUS.PVC.001

● Technical information PVC Page 136

Connector 1

Connector 2

Connector 3

Connector 4

Connector 5

M12, 5 poles socket,

M12, 5 poles pin,

M12, 5 poles pin,

M12, 5 poles socket,

M12, 5 poles socket,

straight

straight

angled

angled

angled

Delivery program (PVC) Delivery program Part No.

Harnessed with

Number of cores and

connector

conductor nominal cross

ø [mm]

Bending radius

2

combination

section [mm ]

BUS9041004

1

1

(2x0,25)C

8,0

12,5 x d

BUS9041001

1

2

(2x0,25)C

8,0

12,5 x d

BUS9041011

1

5

(2x0,25)C

8,0

12,5 x d

BUS9041006

1

6

(2x0,25)C

8,0

12,5 x d

BUS9041005

1

13

(2x0,25)C

8,0

12,5 x d

BUS9041002

2

2

(2x0,25)C

8,0

12,5 x d

Connector 6

Connector 7*

Connector 8*

Connector 9*

Connector 10*

BUS9041013

2

5

(2x0,25)C

8,0

12,5 x d

M12, 5 poles pin,

SUB-D, 9 poles pin,

SUB-D, 9 poles pin,

SUB-D, 9 poles pin,

SUB-D, 9 poles pin,

BUS9041007

2

6

(2x0,25)C

8,0

12,5 x d

angled

straight

end plug, 90°

45°, IP67

end plug, 45°

BUS9041054

2

7

(2x0,25)C

8,0

12,5 x d

BUS9041059

2

8

(2x0,25)C

8,0

12,5 x d

BUS9041062

2

9

(2x0,25)C

8,0

12,5 x d

BUS9041055

2

10

(2x0,25)C

8,0

12,5 x d

BUS9041003

2

13

(2x0,25)C

8,0

12,5 x d

BUS9041066

3

4

(2x0,25)C

8,0

12,5 x d

BUS9041064

3

13

(2x0,25)C

8,0

12,5 x d

Connector 11*

BUS9041065

4

13

(2x0,25)C

8,0

12,5 x d

Connector 12*

Connector 13

BUS9041014

5

5

(2x0,25)C

8,0

12,5 x d

open end of cable

SUB-D, 9 poles

SUB-D, 9 poles

BUS9041010

5

6

(2x0,25)C

8,0

12,5 x d

socket/pin, pass,

socket/pin, pass,

BUS9041012

5

13

(2x0,25)C

8,0

12,5 x d

angled 45°

angled 90°

BUS9041009

6

6

(2x0,25)C

8,0

12,5 x d

BUS9041008

6

13

(2x0,25)C

8,0

12,5 x d

BUS9041053

7

IN 2/OUT 1

(2x0,25)C

8,0

12,5 x d

BUS9041056

7

13

(2x0,25)C

8,0

12,5 x d

BUS9041061

8

IN 2/OUT 1

(2x0,25)C

8,0

12,5 x d

BUS9041060

9

IN 2/OUT 1

(2x0,25)C

8,0

12,5 x d

BUS9041063

9

13

(2x0,25)C

8,0

12,5 x d

BUS9041052

10

IN 2/OUT 1

(2x0,25)C

8,0

12,5 x d

BUS9041057

10

13

(2x0,25)C

8,0

12,5 x d

BUS9041058

11 IN 13/OUT 13

(2x0,25)C

8,0

12,5 x d

BUS9041051

12

(2x0,25)C

8,0

12,5 x d

IN 2/OUT 1

* Plugs with IN and OUT connection always will be connected on the IN side if the cable is assembled. More combinations on request.

eplan download, configurator www.igus.eu/en/Profibus Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 308

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

309


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:07 Seite 310

Network Profibus PUR

Network Profibus PUR

Network technique Profibus cables PUR

CFBUS.PUR.001

● Technical information PUR Page 138

Connector 1

Connector 2

Connector 3

Connector 4

Connector 5

M12, 5 poles socket,

M12, 5 poles Pin,

M12, 5 poles Pin,

M12, 5 poles socket,

M12, 5 poles socket,

straight

straight

angled

angled

angled

Delivery program (PUR) Delivery program Part No.

Harnessed with

Number of cores and

connector

conductor nominal cross

ø [mm]

Bending radius

2

combination

section [mm ]

BUS9041104

1

1

(2x0,25)C

8,0

12,5 x d

BUS9041101

1

2

(2x0,25)C

8,0

12,5 x d

BUS9041111

1

5

(2x0,25)C

8,0

12,5 x d

BUS9041106

1

6

(2x0,25)C

8,0

12,5 x d

BUS9041105

1

13

(2x0,25)C

8,0

12,5 x d

BUS9041102

2

2

(2x0,25)C

8,0

12,5 x d

Connector 6

Connector 7*

Connector 8*

Connector 9*

Connector 10*

BUS9041113

2

5

(2x0,25)C

8,0

12,5 x d

M12, 5 poles Pin,

SUB-D, 9 poles Pin,

SUB-D, 9 poles Pin,

SUB-D, 9 poles Pin,

SUB-D, 9 poles Pin,

BUS9041107

2

6

(2x0,25)C

8,0

12,5 x d

angled

straight

end plug, 90°

45°, IP67

end plug, 45°

BUS9041154

2

7

(2x0,25)C

8,0

12,5 x d

BUS9041159

2

8

(2x0,25)C

8,0

12,5 x d

BUS9041162

2

9

(2x0,25)C

8,0

12,5 x d

BUS9041155

2

10

(2x0,25)C

8,0

12,5 x d

BUS9041103

2

13

(2x0,25)C

8,0

12,5 x d

BUS9041166

3

4

(2x0,25)C

8,0

12,5 x d

BUS9041164

3

13

(2x0,25)C

8,0

12,5 x d

Connector 11*

BUS9041165

4

13

(2x0,25)C

8,0

12,5 x d

Connector 12*

Connector 13

BUS9041114

5

5

(2x0,25)C

8,0

12,5 x d

open end of cable

SUB-D, 9 poles

SUB-D, 9 poles

BUS9041110

5

6

(2x0,25)C

8,0

12,5 x d

socket/Pin, pass,

socket/Pin, pass,

BUS9041112

5

13

(2x0,25)C

8,0

12,5 x d

angled 45°

angled 90°

BUS9041109

6

6

(2x0,25)C

8,0

12,5 x d

BUS9041108

6

13

(2x0,25)C

8,0

12,5 x d

BUS9041153

7

IN 2/OUT 1

(2x0,25)C

8,0

12,5 x d

BUS9041156

7

13

(2x0,25)C

8,0

12,5 x d

BUS9041161

8

IN 2/OUT 1

(2x0,25)C

8,0

12,5 x d

BUS9041160

9

IN 2/OUT 1

(2x0,25)C

8,0

12,5 x d

BUS9041163

9

13

(2x0,25)C

8,0

12,5 x d

BUS9041152

10

IN 2/OUT 1

(2x0,25)C

8,0

12,5 x d

BUS9041157

10

13

(2x0,25)C

8,0

12,5 x d

BUS9041158

11 IN 13/OUT 13

(2x0,25)C

8,0

12,5 x d

BUS9041151

12

(2x0,25)C

8,0

12,5 x d

IN 2/OUT 1

* Plugs with IN and OUT connection always will be connected on the IN side if the cable is assembled. More combinations on request.

eplan download, configurator www.igus.eu/en/Profibus Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 310

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

311


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:08 Seite 312

Network Profibus TPE

Network Profibus TPE

Network technique Profibus cables TPE

CFBUS.001

● Technical information TPE Page 140

Connector 1

Connector 2

Connector 3

Connector 4

Connector 5

M12, 5 poles socket,

M12, 5 poles pin,

M12, 5 poles pin,

M12, 5 poles socket,

M12, 5 poles socket,

straight

straight

angled

angled

angled

Delivery program (TPE) Delivery program Part No.

Harnessed with

Number of cores and

connector

conductor nominal cross

ø [mm]

Bending radius

2

combination

section [mm ]

BUS9041204

1

1

(2x0,25)C

8,0

12,5 x d

BUS9041201

1

2

(2x0,25)C

8,0

12,5 x d

BUS9041211

1

5

(2x0,25)C

8,0

12,5 x d

BUS9041206

1

6

(2x0,25)C

8,0

12,5 x d

BUS9041205

1

13

(2x0,25)C

8,0

12,5 x d

BUS9041202

2

2

(2x0,25)C

8,0

12,5 x d

Connector 6

Connector 7*

Connector 8*

Connector 9*

Connector 10*

BUS9041213

2

5

(2x0,25)C

8,0

12,5 x d

M12, 5 poles pin,

SUB-D, 9 poles pin,

SUB-D, 9 poles pin,

SUB-D, 9 poles pin,

SUB-D, 9 poles pin,

BUS9041207

2

6

(2x0,25)C

8,0

12,5 x d

angled

straight

end plug, 90°

45°, IP67

end plug, 45°

BUS9041254

2

7

(2x0,25)C

8,0

12,5 x d

BUS9041259

2

8

(2x0,25)C

8,0

12,5 x d

BUS9041262

2

9

(2x0,25)C

8,0

12,5 x d

BUS9041255

2

10

(2x0,25)C

8,0

12,5 x d

BUS9041203

2

13

(2x0,25)C

8,0

12,5 x d

BUS9041266

3

4

(2x0,25)C

8,0

12,5 x d

BUS9041264

3

13

(2x0,25)C

8,0

12,5 x d

Connector 11*

BUS9041265

4

13

(2x0,25)C

8,0

12,5 x d

Connector 12*

Connector 13

BUS9041214

5

5

(2x0,25)C

8,0

12,5 x d

open end of cable

SUB-D, 9 poles

SUB-D, 9 poles

BUS9041210

5

6

(2x0,25)C

8,0

12,5 x d

socket/pin, pass,

socket/pin, pass,

BUS9041212

5

13

(2x0,25)C

8,0

12,5 x d

angled 45°

angled 90°

BUS9041209

6

6

(2x0,25)C

8,0

12,5 x d

BUS9041208

6

13

(2x0,25)C

8,0

12,5 x d

BUS9041253

7

IN 2/OUT 1

(2x0,25)C

8,0

12,5 x d

BUS9041256

7

13

(2x0,25)C

8,0

12,5 x d

BUS9041261

8

IN 2/OUT 1

(2x0,25)C

8,0

12,5 x d

BUS9041260

9

IN 2/OUT 1

(2x0,25)C

8,0

12,5 x d

BUS9041263

9

13

(2x0,25)C

8,0

12,5 x d

BUS9041252

10

IN 2/OUT 1

(2x0,25)C

8,0

12,5 x d

BUS9041257

10

13

(2x0,25)C

8,0

12,5 x d

BUS9041258

11 IN 13/OUT 13

(2x0,25)C

8,0

12,5 x d

BUS9041251

12

(2x0,25)C

8,0

12,5 x d

IN 2/OUT 1

* Plugs with IN and OUT connection always will be connected on the IN side if the cable is assembled. More combinations on request.

eplan download, configurator www.igus.eu/en/Profibus Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 312

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

313


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:08 Seite 314

®

®

chainflex readycable Cable type

Jacket Page

Initiators CF9 - CF.INI (minimum bending radius 5 x d) Direct line M12 x 1, straight/angled

TPE

316

Direct line M12 x 1, straight/angled, LED

TPE

317

Connecting cable M12 x 1, straight/angled

TPE

318

Direct line M8 x 1, straight/angled

TPE

319

Direct line M8 x 1, angled, LED

TPE

320

Connecting cable M8 x 1, straight/angled

TPE

321

Direct line M12 x 1, straight/angled

TPE

322

Connecting cable M12 x 1, straight/angled

TPE

323

Direct line M12 x 1, straight/angled

TPE

324

Connecting cable M12 x 1, straight/angled

TPE

325

Direct line M8 x 1, straight/angled

TPE

326

Connecting cable M8 x 1, straight/angled

TPE

327

Direct line M23, straight

TPE

328

Connecting cable M23, straight/angled

TPE

329

Initiators CF10 – CF.INI (minimum bending radius 5 x d) 360° shielded

Initiators

CF.INI

Initiators CF98 - CF.INI (minimum bending radius 4 x d)

chainflex® cables for actuator/sensor distribution box

315


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:08 Seite 316

CF.INI | chainflex® Sensor/actuator cables

CF.INI | chainflex® Sensor/actuator cables

chainflex® Sensor/actuator cables with 5xd for energy chains® Direct line M12 x 1: Socket with free cable end Connector-type connector Coupling, M12 x 1 BG BW

chainflex® Sensor/actuator cables with 5xd for energy chains® Direct line M12 x 1: Socket with LED and free cable end Connector-type connector Coupling, M12 x 1 BGL BWL

Handle base Union nut/screw Contact base Contacts Seal

Plastic, PP, black Metal, CuZn, nickel-plated Plastic, PP, black Metal, CuZn, gold-plated Plastic, FPM (Viton)

Handle base Union nut/screw Contact base Contacts Seal

Plastic, TPU, transparent Metal, CuZn, nickel-plated Plastic, PA6GF, transparent Metal, CuZn, gold-plated Plastic, FPM (Viton)

Number of poles Ampacity Rated voltage of a winding

4-p ole 4A max. 250 V

Number of poles Ampacity Rated voltage of a winding

4-p ole 4A 10...30 V

Number of poles Ampacity Rated voltage of a winding

5-p ole (4-p ole + PE) 4A max. 60 V

Insulation resistance Contact resistance Degree of soiling

≥10 9 Ω ≤5 m Ω 3/2

Insulation resistance Contact resistance Degree of soiling

≥10 9 Ω ≤5 m Ω 3/2

Operating voltage display Switching state display Switching function

LED green LED yellow/yellow pnp

M12 x 1

26,5

ø 15

M12 x 1 42 ø 10,2 ø 11,6

ø 15

31,5

ø 8,8 ø 11,6

12

2 WH

12

2 WH

1 BN

3 BU

1 BN

4 BK

3 BU 4 BK

M12 x 1

Ambient temperature of plug-type connector Protection class Mechanical service life

-40 ... +105 °C IP69K, in screwed state max. 100 insertion cycles

LED

M12 x 1

12

1 BN

Type

31,5

ø 8,8 ø 11,6

12

2 WH

2 WH 3 BU

1 BN

4 BK GN

2 3

3 BU 4 BK

BN

1+

YE

Direct line M12 (CF9.03.04.INI*/CF9.03.05.INI*) ®

ø 15

45,5 ø 10,2 ø 11,6

-40 ... +105 °C IP66, in screwed state max.100 insertion cycles

LEDs

26,5

ø 15

4

Ambient temperature of plug-type connector Protection class Mechanical service life

BN

1+ GN

BK

WH

4 YE

WH

BK

2 YE

BU

BU

3

Direct line M12 (CF9.03.04.INI*)

igus

Number of cores and conductor

Number

Cable length

Part No.

nominal cross section [mm2]

of poles

[m]

Direct line straight

®

Type

igus

Number of cores and conductor

Number

Cable length

Part No.

nominal cross section [mm2]

of poles

[m]

Direct line with LED straight

CF.INI-P4-M12-BG-3

MAT9043700

4x0,34

4

3,0

CF.INI-P4-M12-BGL2-3

MAT9043708

4x0,34

4

3,0

CF.INI-P4-M12-BG-5

MAT9043701

4x0,34

4

5,0

CF.INI-P4-M12-BGL2-5

MAT9043709

4x0,34

4

5,0

CF.INI-P4-M12-BG-7

MAT9043702

4x0,34

4

7,0

CF.INI-P4-M12-BGL2-7

MAT9043710

4x0,34

4

7,0

CF.INI-P4-M12-BG-10

MAT9043703

4x0,34

4

10,0

CF.INI-P4-M12-BGL2-10

MAT9043711

4x0,34

4

10,0

CF.INI-P4-M12-BG-15

MAT9049426

4x0,34

4

15,0

CF.INI-P4-M12-BGL2-15

MAT90410087

4x0,34

4

15,0

CF.INI-P5-M12-BG-3

MAT9043737

5x0,34

5

3,0

CF.INI-P5-M12-BG-5

MAT9043738

5x0,34

5

5,0

CF.INI-P5-M12-BG-7

MAT9043739

5x0,34

5

7,0

CF.INI-P5-M12-BG-10

MAT9043740

5x0,34

5

10,0

CF.INI-P4-M12-BWL3-3

MAT9043712

4x0,34

4

3,0

CF.INI-P5-M12-BG-15

MAT90410077

5x0,34

5

15,0

CF.INI-P4-M12-BWL3-5

MAT9043713

4x0,34

4

5,0

CF.INI-P4-M12-BWL3-7

MAT9043714

4x0,34

4

7,0

Direct line angled CF.INI-P4-M12-BW-3

MAT9043704

4x0,34

4

3,0

CF.INI-P4-M12-BW-5

MAT9043705

4x0,34

4

5,0

CF.INI-P4-M12-BW-7

MAT9043706

4x0,34

4

7,0

CF.INI-P4-M12-BW-10

MAT9043707

4x0,34

4

10,0

CF.INI-P4-M12-BW-15

MAT9049430

4x0,34

4

15,0

CF.INI-P5-M12-BW-3

MAT9043742

5x0,34

5

3,0

CF.INI-P5-M12-BW-5

MAT9043743

5x0,34

5

5,0

CF.INI-P5-M12-BW-7

MAT9043744

5x0,34

5

7,0

CF.INI-P5-M12-BW-10

MAT9043745

5x0,34

5

10,0

CF.INI-P5-M12-BW-15

MAT90410078

5x0,34

5

15,0

G = with green-yellow earth core

x = without earth core

* Technical information

Direct line with LED angled

CF.INI-P4-M12-BWL3-10

MAT9043715

4x0,34

4

10,0

CF.INI-P4-M12-BWL3-15

MAT90410088

4x0,34

4

15,0

eplan download, configurator www.igus.eu/en/CFINI Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * Technical information Page 90 G = with green-yellow earth core x = without earth core

Page 90

950 types from stock no cutting costs ... 316

CF.INI CF9 M12

CF9

CF9

CF.INI CF9 M12

(for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

317


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:09 Seite 318

CF.INI | chainflex® Sensor/actuator cables

CF.INI | chainflex® Sensor/actuator cables

chainflex® Sensor/actuator cables with 5xd for energy chains® Connection cable M12 x 1: Socket, cable end with pin Connector-type connector Coupling, M12 x 1 BG SG BW

chainflex® Sensor/actuator cables with 5xd for energy chains® Direct line M8 x 1: Socket with free cable end Connector-type connector Coupling, M8 x 1 BG BW

Handle base Union nut/screw Contact base Contacts Seal

Handle base Union nut/screw Contact base Contacts Seal

Plastic, PP, black Metal, CuZn, nickel-plated Plastic, PP, black Metal, CuZn, gold-plated Plastic, FPM (Viton)

Number of poles Ampacity Rated voltage of a winding

3- p o l e 4A max. 60 V

Number of poles Ampacity Rated voltage of a winding

4- p o l e 4A max. 30 V

Insulation resistance Contact resistance Degree of soiling

≥10 9 Ω ≤5 m Ω 3/2

Ambient temperature of plug-type connector Protection class Mechanical service life

-40 ... +105 °C IP69K, in screwed state max. 100 insertion cycles

Plastic, PP, black Metal, CuZn, nickel-plated Plastic, PP, black Metal, CuZn, gold-plated Plastic, FPM (Viton)

M12 x 1

26,5

M12 x 1

ø 15

ø 15

M12 x 1

42

Connector-type connector Handle base Union nut/screw Contact base Contacts

Connector, M12 x 1 Plastic, PP, black Metal, CuZn, nickel-plated Plastic, TPU, black Metal, CuZn, gold-plated

Rated voltage of a winding

4-pole: max. 250 V 5-p ole (4-p ole+PE): max. 60 V 1 BN 4A ≥10 9 Ω ≤5 m Ω 3/2

Ampacity Insulation resistance Contact resistance Degree of soiling Ambient temperature of plug-type connector Protection class Mechanical service life

ø 10,2 ø 11,6

12

ø 15

52 ø 10,2 ø 11,6

ø 8,8 ø 11,6

12

2 WH

2 WH 3 BU 3 BU

12

2 WH 1 BN 1 BN

4 BK

4 BK

31,5

3 BU 4 BK

-40 ... +105 °C IP69K, in screwed state max. 100 insertion cycles

Connection cable M12 (CF9.03.04.INI*/CF9.03.05.INI*) ®

igus

Type

Part No.

Number of cores and conductor 2

nominal cross section [mm ]

M8 x 1

ø 9,6

16,5

M8 x 1 34

28

ø 9,5

4 BK

4 BK

3 BU

1 BN

3 BU

1 BN

4 BK

2 WH

4 BK

2 WH

3 BU

1 BN

3 BU

1 BN

Direct line M8 (CF9.02.03.INI*/CF9.03.04.INI*)

Number

Cable length

of poles

[m]

Connection cable straight

Type

igus®

Number of cores and conductor

Number

Cable length

Part No.

nominal cross section [mm2]

of poles

[m]

Direct line straight

CF.INI-P4-M12-BG/M12-SG-2

MAT90410312

4x0,34

4

2,0

CF.INI-P3-M8-BG-3

MAT9043716

3x0,25

3

3,0

CF.INI-P4-M12-BG/M12-SG-5

MAT90410313

4x0,34

CF.INI-P4-M12-BG/M12-SG-10

MAT90410314

4x0,34

4

5,0

CF.INI-P3-M8-BG-5

MAT9043717

3x0,25

3

5,0

4

10,0

CF.INI-P3-M8-BG-7

MAT9043718

3x0,25

3

7,0

CF.INI-P5-M12-BG/M12-SG-2

MAT90410339

CF.INI-P5-M12-BG/M12-SG-5

MAT90410340

5x0,34

5

2,0

CF.INI-P3-M8-BG-10

MAT9043719

3x0,25

3

10,0

5x0,34

5

5,0

CF.INI-P3-M8-BG-15

MAT9049416

3x0,25

3

15,0

CF.INI-P5-M12-BG/M12-SG-10

MAT90410341

5x0,34

5

10,0

CF.INI-P4-M8-BG-3

MAT9043728

4x0,34

4

3,0

CF.INI-P4-M8-BG-5

MAT9043729

4x0,34

4

5,0

CF.INI-P4-M8-BG-7

MAT9043730

4x0,34

4

7,0

CF.INI-P4-M8-BG-10

MAT9043731

4x0,34

4

10,0

CF.INI-P4-M8-BG-15

MAT9049466

4x0,34

4

15,0

Connection cable angled CF.INI-P4-M12-BW/M12-SG-2

MAT90410315

4x0,34

4

2,0

CF.INI-P4-M12-BW/M12-SG-5

MAT90410316

4x0,34

4

5,0

CF.INI-P4-M12-BW/M12-SG-10 MAT90410317

4x0,34

4

10,0

CF.INI-P5-M12-BW/M12-SG-2

MAT90410342

5x0,34

5

2,0

Direct line angled

CF.INI-P5-M12-BW/M12-SG-5

MAT90410343

5x0,34

5

5,0

CF.INI-P3-M8-BW-3

MAT9043724

3x0,25

3

3,0

CF.INI-P5-M12-BW/M12-SG-10 MAT90410344

5x0,34

5

10,0

CF.INI-P3-M8-BW-5

MAT9043725

3x0,25

3

5,0

CF.INI-P3-M8-BW-7

MAT9043726

3x0,25

3

7,0

CF.INI-P3-M8-BW-10

MAT9043727

3x0,25

3

10,0

CF.INI-P3-M8-BW-15

MAT9049419

3x0,25

3

15,0

CF.INI-P4-M8-BW-3

MAT9043732

4x0,34

4

3,0

CF.INI-P4-M8-BW-5

MAT9043733

4x0,34

4

5,0

CF.INI-P4-M8-BW-7

MAT9043734

4x0,34

4

7,0

CF.INI-P4-M8-BW-10

MAT9043735

4x0,34

4

10,0

CF.INI-P4-M8-BW-15

MAT9049467

4x0,34

4

15,0

eplan download, configurator www.igus.eu/en/CFINI Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * Technical information Page 90 G = with green-yellow earth core x = without earth core

G = with green-yellow earth core

950 types from stock no cutting costs ... 318

CF.INI CF9 M8

CF9

CF9

CF.INI CF9 M12

(for up to 10 cuts of the same type)

x = without earth core

* Technical information

Page 90

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

319


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:09 Seite 320

CF.INI CF9 M8

CF.INI | chainflex® Sensor/actuator cables

CF.INI | chainflex® Sensor/actuator cables

chainflex® Sensor/actuator cables with 5xd for energy chains® Direct line M8 x 1: Socket with LED and free cable end Connector-type connector Coupling, M8 x 1 BWL

chainflex® Sensor/actuator cables with 5xd for energy chains® Connection cable M8 x 1: Socket, cable end with pin Connector-type connector Coupling, M8 x 1 BG SG BW

Handle base Union nut/screw Contact base Contacts Seal

Plastic, TPU, transparent Metal, CuZn, nickel-plated Plastic, PA6GF, black Metal, CuZn, gold-plated Plastic, FPM (Viton)

Handle base Union nut/screw Contact base Contacts Seal

Plastic, PP, black Metal, CuZn, nickel-plated Plastic, PP, black ø 9,6 Metal, CuZn, gold-plated Plastic, FPM (Viton)

Number of poles Ampacity Rated voltage of a winding

3-p ole 4A 10...30 V

Insulation resistance Contact resistance Degree of soiling

≥10 9 Ω ≤5 m Ω 3/2

Connector-type connector Handle base Union nut/screw Contact base Contacts

Connector, M8 x 1 Plastic, PP, black Metal, CuZn, nickel-plated Plastic, PP, black Metal, CuZn, gold-plated

Rated voltage of a winding

Operating voltage display Switching state display Switching function

LED green LED yellow pnp

Ampacity Insulation resistance Contact resistance Degree of soiling

3-pole: max. 60 V 4-pole: max. 30 V 4A ≥10 9 Ω ≤5 m Ω 3/2

Ambient temperature of plug-type connector Protection class Mechanical service life

-40 ... +105 °C IP69K, in screwed state max. 100 insertion cycles

Ambient temperature of plug-type connector Protection class Mechanical service life

LED

16,5 M8 x 1

28,3

ø 9,6

23,5

4 BK

3 BU

1 BN

BN

1+ GN

-40 ... +105 °C IP66K, in screwed state max. 100 insertion cycles

4

BK

YE BU

3

igus

Type

Part No.

Number of cores and conductor 2

nominal cross section [mm ]

16,5

M8 x 1

M8 x 1

ø 9,6 34

Direct line M8 (CF9.02.03.INI*) ®

M8 x 1

CF9

CF9

CF.INI CF9 M8

4 BK

28

ø 9,5

41,2

4 BK

4 BK

3 BU

1 BN

1 BN

3 BU

3 BU

1 BN

4 BK

2 WH

2 WH

4 BK

4 BK

2 WH

3 BU

1 BN

1 BN

3 BU

3 BU

1 BN

Connection cable M8 (CF9.02.03.INI*/CF9.03.04.INI*) Number

Cable length

of poles

[m]

Direct line with LED angled

Type

igus®

Number of cores and conductor

Number

Cable length

Part No.

nominal cross section [mm2]

of poles

[m]

Connection cable straight

CF.INI-P3-M8-BWL2-3

MAT9043720

3x0,25

3

3,0

CF.INI-P3-M8-BG/M8-SG-2

MAT90410324

3x0,25

3

2,0

CF.INI-P3-M8-BWL2-5

MAT9043721

3x0,25

3

5,0

CF.INI-P3-M8-BG/M8-SG-5

MAT90410325

3x0,25

3

5,0

CF.INI-P3-M8-BWL2-7

MAT9043722

3x0,25

3

7,0

CF.INI-P3-M8-BG/M8-SG-10

MAT90410326

3x0,25

3

10,0

CF.INI-P3-M8-BWL2-10

MAT9043723

3x0,25

3

10,0

CF.INI-P4-M8-BG/M8-SG-2

MAT90410333

4x0,34

4

2,0

CF.INI-P3-M8-BWL2-15

MAT90410196

3x0,25

3

15,0

CF.INI-P4-M8-BG/M8-SG-5

MAT90410334

4x0,34

4

5,0

CF.INI-P4-M8-BG/M8-SG-10

MAT90410335

4x0,34

4

10,0

CF.INI-P3-M8-BW/M8-SG-2

MAT90410330

3x0,25

3

2,0

CF.INI-P3-M8-BW/M8-SG-5

MAT90410331

3x0,25

3

5,0

CF.INI-P3-M8-BW/M8-SG-10

MAT90410332

3x0,25

3

10,0

CF.INI-P4-M8-BW/M8-SG-2

MAT90410336

4x0,34

4

2,0

CF.INI-P4-M8-BW/M8-SG-5

MAT90410337

4x0,34

4

5,0

CF.INI-P4-M8-BW/M8-SG-10

MAT90410338

4x0,34

4

10,0

Connection cable angled

eplan download, configurator www.igus.eu/en/CFINI

eplan download, configurator www.igus.eu/en/CFINI

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * Technical information Page 90 G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 320

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * Technical information Page 90 G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

321


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:09 Seite 322

CF.INI | chainflex® Sensor/actuator cables

CF.INI | chainflex® Sensor/actuator cables

chainflex® Sensor/actuator cables with 5xd for energy chains® Direct line 360° shielded, M12 x 1: Socket with free cable end Connector-type connector Coupling, M12 x 1 BG BW

chainflex® Sensor/actuator cables with 5xd for energy chains® Connection cable 360° shielded, M12 x 1: Socket, cable end with pin Connector-type connector Coupling, M12 x 1 BW BG SG

Handle base Union nut/screw Contact base Contacts Seal

Plastic, PP, black Metal, CuZn, nickel-plated Plastic, PP, black Metal, CuZn, gold-plated Plastic, FPM (Viton)

Handle base Union nut/screw Contact base Contacts Seal

Plastic, PP, black Metal, CuZn, nickel-plated Plastic, PP, black Metal, CuZn, gold-plated Plastic, FPM (Viton)

Number of poles Ampacity Rated voltage of a winding

5-pole (4-pole + PE) 4A max. 60 V

Number of poles Ampacity Rated voltage of a winding

5-pole (4-pole + PE) 4A max. 60 V

Insulation resistance Contact resistance Degree of soiling

≥10 9 Ω ≤5 m Ω 3/2

Insulation resistance Contact resistance Degree of soiling

≥10 9 Ω ≤5 m Ω 3/2

-40 ... +105 °C IP69K, in screwed state max. 100 insertion cycles

Ambient temperature of plug-type connector Protection class Mechanical service life

-40 ... +105 °C IP69K, in screwed state max. 100 insertion cycles

Ambient temperature of plug-type connector Protection class Mechanical service life

M12 x 1

26,5

ø 15 M12 x 1 ø 15

42 ø 10,2 ø 11,6

ø 8,8 ø 11,6

12

31,5 12

M12 x 1

26,5

M12 x 1

ø 15

ø 15

ø 10,2 ø 11,6

12

52 ø 10,2 ø 11,6

brown white blue black green-yellow

igus

Type

Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø 15

31,5

ø 8,8 ø 11,6

12

12

brown white blue black green-yellow Schirm aufgelegt Shielded

Direct line M12 (CF10.03.05.INI*) ®

M12 x 1

42

Shielded

Connection cable M12 (CF10.03.05.INI*) Number

Cable length

of poles

[m]

Direct line 360° shielded straight

Type

igus®

Number of cores and conductor

Number

Cable length

Part No.

nominal cross section [mm2]

of poles

[m]

Connection cable 360° shielded straight

CF10.INI-P5-C-M12-BG-3

MAT90424072

5x0,34

5

3,0

CF10.INI-P5-C-M12-BG/M12-SG-2

MAT90424082

5x0,34

5

2,0

CF10.INI-P5-C-M12-BG-5

MAT90424073

5x0,34

5

5,0

CF10.INI-P5-C-M12-BG/M12-SG-5

MAT90424083

5x0,34

5

5,0

CF10.INI-P5-C-M12-BG-7

MAT90424074

5x0,34

5

7,0

CF10.INI-P5-C-M12-BG/M12-SG-10 MAT90424084

5x0,34

5

10,0

CF10.INI-P5-C-M12-BG-10

MAT90424075

5x0,34

5

10,0

CF10.INI-P5-C-M12-BG-15

MAT90424076

5x0,34

5

15,0

Direct line 360° shielded angled CF10.INI-P5-C-M12-BW-3

MAT90424077

5x0,34

5

3,0

CF10.INI-P5-C-M12-BW-5

MAT90424078

5x0,34

5

5,0

CF10.INI-P5-C-M12-BW-7

MAT90424079

5x0,34

5

7,0

CF10.INI-P5-C-M12-BW-10

MAT90424080

5x0,34

5

10,0

CF10.INI-P5-C-M12-BW-15

MAT90424081

5x0,34

5

15,0

eplan download, configurator www.igus.eu/en/CFINI

Connection cable 360° shielded angled CF10.INI-P5-C-M12-BW/M12-SG-2

MAT90424085

5x0,34

5

2,0

CF10.INI-P5-C-M12-BW/M12-SG-5

MAT90424086

5x0,34

5

5,0

CF10.INI-P5-C-M12-BW/M12-SG-10 MAT90424087

5x0,34

5

10,0

eplan download, configurator www.igus.eu/en/CFINI

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * Technical information Page 94 G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 322

CF.INI CF10 M12

CF10

CF10

CF.INI CF10 M12

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * Technical information Page 94 G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

323


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:09 Seite 324

CF.INI | chainflex® Sensor/actuator cables

CF.INI | chainflex® Sensor/actuator cables

chainflex® Sensor/actuator cables with 4xd for energy chains® Direct line M12 x 1: Socket with free cable end Connector-type connector Coupling, M12 x 1 BG BW

chainflex® Sensor/actuator cables with 4xd for energy chains® Connection cable M12 x 1: Socket, cable end with pin Connector-type connector Coupling, M12 x 1 BG SG BW

Handle base Union nut/screw Contact base Contacts Seal

Plastic, PP, black Metal, CuZn, nickel-plated Plastic, PP, black Metal, CuZn, gold-plated Plastic, FPM (Viton)

M12 x 1 ø 15 M12 x 1

4-p ole 4A max. 250 V

Insulation resistance Contact resistance Degree of soiling

≥10 9 Ω ≤5 m Ω 3/2

Ambient temperature of plug-type connector Protection class Mechanical service life

-40 ... +105 °C IP69K, in screwed state max. 100 insertion cycles

ø 10,2 ø 11,6

2 WH 1 BN

31,5

ø 8,8 ø 11,6

12

12

2 WH 3 BU

1 BN

4 BK

Plastic, PP, black Metal, CuZn, nickel-plated Plastic, TPU, black Metal, CuZn, gold-plated Plastic, FPM (Viton)

®

igus

Type

Part No.

Number of cores and conductor 2

nominal cross section [mm ]

M12 x 1 M12 x 1

ø 15

26,5

ø 15

M12 x 1 52

42

ø 15

42

Number of poles Ampacity Rated voltage of a winding

Handle base Union nut/screw Contact base Contacts Seal

26,5

3 BU 4 BK

Connector-type connector Handle base Union nut/screw Contact base Contacts

Connector, M12x1 Plastic, PP, black Metal, CuZn, nickel-plated Plastic, TPU, black Metal, CuZn, gold-plated

Rated voltage of a winding Ampacity Insulation resistance Contact resistance Degree of soiling

4-pole: max. 250V 4A ≥10 9 Ω ≤5 m Ω 3/2

Ambient temperature of plug-type connector Protection class Mechanical service life

-40 ... +105 °C IP69K, in screwed state max.100 insertion cycles

ø 10,2 ø 11,6

12

ø 10,2 ø 11,6

1 BN

ø 15

3 BU

12

3 BU

31,5

ø 8,8 ø 11,6

2 WH

2 WH

4 BK

Direct line M12 (CF98.03.04.INI*)

12

2 WH 1 BN

4 BK

1 BN

3 BU 4 BK

Connection cable M12 (CF98.03.04.INI*) Number

Cable length

of poles

[m]

Direct line straight

Type

igus®

Number of cores and conductor

Number

Cable length

Part No.

nominal cross section [mm2]

of poles

[m]

Connection cable straight

CF98.INI-P4-M12-BG-3

MAT90410235

4x0,34

4

3,0

CF98.INI-P4-M12-BG/M12-SG-2

MAT90410300

4x0,34

4

2,0

CF98.INI-P4-M12-BG-5

MAT90410236

4x0,34

4

5,0

CF98.INI-P4-M12-BG/M12-SG-5

MAT90410301

4x0,34

4

5,0

CF98.INI-P4-M12-BG-7

MAT90410237

4x0,34

4

7,0

CF98.INI-P4-M12-BG/M12-SG-10 MAT90410302

4x0,34

4

10,0

CF98.INI-P4-M12-BG-10

MAT90410238

4x0,34

4

10,0

CF98.INI-P4-M12-BG-15

MAT90410239

4x0,34

4

15,0

CF98.INI-P4-M12-BW/M12-SG-2 MAT90410303

4x0,34

4

2,0

CF98.INI-P4-M12-BW/M12-SG-5 MAT90410304

4x0,34

4

5,0

CF98.INI-P4-M12-BW/M12-SG-10 MAT90410305

4x0,34

4

10,0

Direct line angled CF98.INI-P4-M12-BW-3

MAT90410240

4x0,34

4

3,0

CF98.INI-P4-M12-BW-5

MAT90410241

4x0,34

4

5,0

CF98.INI-P4-M12-BW-7

MAT90410242

4x0,34

4

7,0

CF98.INI-P4-M12-BW-10

MAT90410243

4x0,34

4

10,0

CF98.INI-P4-M12-BW-15

MAT90410244

4x0,34

4

15,0

eplan download, configurator www.igus.eu/en/CFINI

Connection cable angled

eplan download, configurator www.igus.eu/en/CFINI

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * Technical information Page 106 G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 324

CF.INI CF98 M12

CF98

CF98

CF.INI CF98 M12

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * Technical information Page 106 G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

325


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:09 Seite 326

CF.INI | chainflex® Sensor/actuator cables

CF.INI | chainflex® Sensor/actuator cables

chainflex® Sensor/actuator cables with 4xd for energy chains® Direct line M8 x 1: Socket with free cable end Connector-type connector Coupling, M8 x 1 BG BW

chainflex® Sensor/actuator cables with 4xd for energy chains® Connection cable M8 x 1: Socket, cable end with pin Connector-type connector Coupling, M8 x 1 BG SG

Handle base Union nut/screw Contact base Contacts Seal

Plastic, PP, black Metal, CuZn, nickel-plated Plastic, PP, black Metal, CuZn, gold-plated Plastic, FPM (Viton)

Handle base Union nut/screw Contact base Contacts Seal

Plastic, PP, black Metal, CuZn, nickel-plated Plastic, TPU, black ø 9,6 Metal, CuZn, gold-plated Plastic, FPM (Viton)

Number of poles Ampacity Rated voltage of a winding

3-p ole 4A max. 60 V

Insulation resistance Contact resistance Degree of soiling

≥10 9 Ω ≤5 m Ω 3/2

Connector-type connector Handle base Union nut/screw Contact base Contacts

Connector, M8 x 1 Plastic, PP, black Metal, CuZn, nickel-plated Plastic, PP, black Metal, CuZn, gold-plated

Rated voltage of a winding Ampacity Insulation resistance Contact resistance Degree of soiling

3-pole: max. 60 V 4A ≥10 9 Ω ≤5 m Ω 3/2

Ambient temperature of plug-type connector Protection class Mechanical service life

-40 ... +105 °C IP69K, in screwed state max. 100 insertion cycles

M12 x 1

16,5 16,5

ø 15

M8M8 x 1x 1 42

ø 10,2 ø 11,6

Ambient temperature of plug-type connector Protection class Mechanical service life

-40 ... +105 °C IP69K, in screwed state max. 100 insertion cycles

28 28

ø 9,5 ø 9,5

12

4 BK

4 BK

3 BU

1 BN

3 BU

1 BN

®

igus

Type

Part No.

Number of cores and conductor 2

nominal cross section [mm ]

16,5

M8 x 1

M8 x 1

ø 9,6

4 BK

4 BK

1 BN

1 BN

28

ø 9,5

41,2

4 BK

3 BU

BW

M8 x 1

34

Direct line M8 (CF98.02.03.INI*)

3 BU

3 BU

1 BN

Connection cable M8 (CF98.02.03.INI*) Number

Cable length

of poles

[m]

Direct line straight

Type

igus®

Number of cores and conductor

Number

Cable length

Part No.

nominal cross section [mm2]

of poles

[m]

Connection cable straight

CF98.INI-P3-M8-BG-3

MAT90410245

3x0,25

3

3,0

CF98.INI-P3-M8-BG/M8-SG-2

MAT90410306

3x0,25

3

2,0

CF98.INI-P3-M8-BG-5

MAT90410246

3x0,25

3

5,0

CF98.INI-P3-M8-BG/M8-SG-5

MAT90410307

3x0,25

3

5,0

CF98.INI-P3-M8-BG/M8-SG-10 MAT90410308

3x0,25

3

10,0

CF98.INI-P3-M8-BG-7

MAT90410247

3x0,25

3

7,0

CF98.INI-P3-M8-BG-10

MAT90410248

3x0,25

3

10,0

CF98.INI-P3-M8-BG-15

MAT90410249

3x0,25

3

15,0

Direct line angled CF98.INI-P3-M8-BW-3

MAT90410250

3x0,25

3

3,0

CF98.INI-P3-M8-BW-5

MAT90410251

3x0,25

3

5,0

CF98.INI-P3-M8-BW-7

MAT90410252

3x0,25

3

7,0

CF98.INI-P3-M8-BW-10

MAT90410253

3x0,25

3

10,0

CF98.INI-P3-M8-BW-15

MAT90410254

3x0,25

3

15,0

eplan download, configurator www.igus.eu/en/CFINI

Connection cable angled CF98.INI-P3-M8-BW/M8-SG-2

MAT90410309

3x0,25

3

2,0

CF98.INI-P3-M8-BW/M8-SG-5

MAT90410310

3x0,25

3

5,0

CF98.INI-P3-M8-BW/M8-SG-10 MAT90410311

3x0,25

3

10,0

eplan download, configurator www.igus.eu/en/CFINI

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * Technical information Page 106 G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 326

CF.INI CF98 M8

CF98

CF98

CF.INI CF98 M8

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * Technical information Page 106 G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

327


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:09 Seite 328

CF.INI chainflex® for actuator/sensor distribution box

CF.INI chainflex® for actuator/sensor distribution box

To connect sensor/actuator distribution boxes (5xd) Direct line M23: Socket/pin at the beginning of the cable, cable end is cut

To connect sensor/actuator distribution boxes (5xd) Connecting cable M23: Socket at the beginning of the cable, cable end is pin

● Class 7.4.4 ● Oil-resistant ● Hydrolysis-resistant and microbe-resistant ● T/R moved: -35 °C to +100 °C, minimum bending radius 5 x d

● Class 7.4.4 ● Oil-resistant ● Hydrolysis-resistant and microbe-resistant ● T/R moved: -35 °C to +100 °C, minimum bending radius 5 x d

● Nominal voltage: 300/500 V ● Colour: Steel blue (similar to RAL 5011)

Direct line M23 Part No.

Number of poles

2

nominal cross section [mm ]

ø

Number of poles

Number of cores and conductor 2

nominal cross section [mm ]

ø mm

Connecting cable angled 16+3

(4x4x0,34+3x0,75)

11,0

MAT90436628

16+3

(4x4x0,34+3x0,75)

11,0

16+3

(4x4x0,34+3x0,75)

11,0

Connecting cable straight 16+3

eplan download, configurator

(4x4x0,34+3x0,75)

11,0

www.igus.eu/en/CFINI

MAT90436629

eplan download, configurator

www.igus.eu/en/CFINI

All cables available in the lengths you require.

All cables available in the lengths you require.

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 328

Part No.

mm

Direct line* Pin MAT90436631

● Nominal voltage: 300/500 V ● Colour: Steel blue (similar to RAL 5011)

Connecting cable M23

Number of cores and conductor

Direct line* Socket MAT90436630

CF.INI CF9 M23

CF9

CF9

CF.INI CF9 M23

(for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

329


Drive technology

EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:10 Seite 330

... harnessed cables for Drive Technology ... 速

chainflex readycable Selection table according to manufacturers

Jacket

Page

Harnessed cables for Drive Technology Allen Bradley New*

Power-/servo-/brake cable

PVC/PUR/TPE

338

B&R

Servo-/resolver-/EnDat cables

PVC/PUR/TPE

338

Baum端ller

Servo-/encoder-/pulse encoder-/ PVC/PUR/TPE

338

EtherCAT

PVC/PUR/TPE

341

Berger Lahr

Servo-/resolver cables

PVC/TPE

341

Control Techniques

Power-/servo-/encoder cables

PVC/PUR/TPE

341

Danaher Motion

Power-/servo-/signal cables

PVC/PUR/TPE

343

ELAU

Servo-/encoder cables

PVC/PUR/TPE

345

Fagor

Path measurement cable

TPE

346

Fanuc

Power-/signal cables

PUR/TPE

346

Heidenhain

Adapter cable

PUR/TPE

347

Power-/servo-/resolver cables

PVC/PUR/TPE

347

resolver-/decoder-/fan cable

PVC/PUR/TPE

348

Servo-/encoder cables

PVC/PUR/TPE

348

resolver cable

Beckhoff

Jetter

Servo-/encoder-/resolver cables/

New*

Lenze

LTi DRiVES

Servo-/encoder-/feedback-/

New*

More "Harnessed cables for Drive Technology"

Page 332

To make the choice easier for you, we have classified all chainflex速-cables according to the criteria "requirements, oil-resistance and travel distance". For this reason we have extended the "Technical specifications" by the specification "Class 6.3.3", for example. For detailed information see the inside of the front cover flap. * New in this catalogue.

331


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:10 Seite 332

readycable® Content

... harnessed cables for Drive Technology ... ®

... harnessed cables for Drive Technology ... ®

®

chainflex readycable Selection table according to manufacturers

Jacket

chainflex readycable Page

Harnessed cables for Drive Technology NUM

Harnessed cables for Drive Technology Power-/servo-/encoder-/ sensor-/fan cable

PVC/PUR/TPE

349

Power-/encoder-/control cable

PVC/PUR/TPE

350

Rexroth

Power-/encoder cables

PVC/PUR/TPE

350

SEW

Power-/servo-/encoder cables

PVC/PUR/TPE

352

Siemens

Power-/servo-/signal cables

PVC/PUR/TPE

353

Stöber

Servo-/encoder cables

PVC/PUR/TPE

354

Omron

®

readycable® Content

New*

More "Harnessed cables for Drive Technology"

chainflex® PVC cables for the woodworking industry, for example Typical application area – PVC ● for high load requirements ● light oil influence ● preferably indoor applications, but also outdoor ones at temperatures > 5 °C ● especially for freely suspended and gliding travel distances up to 100 m ● Storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling, indoor cranes, timber processing

Page 331

chainflex® PUR cables for the tooling machine industry, for example Typical application area – PUR ● for maximum load requirements ● almost unlimited resistance to oil ● Indoor and outdoor applications, UV-resistant ● especially for freely suspended and gliding travel distances up to 100 m ● Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, outdoor cranes, low-temperature applications

chainflex® TPE cables for outdoor use, for example Typical application area – TPE ● for maximum load requirements ● almost unlimited resistance to oil, also with bio-oils ● Indoor and outdoor applications, UV-resistant ● especially for freely suspended and gliding travel distances up to 400 m and more ● Storage and retrieval units for high-bay warehouses, machining units/ machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

To make the choice easier for you, we have classified all chainflex®-cables according to the criteria "requirements, oil-resistance and travel distance". For this reason we have extended the "Technical specifications" by the specification "Class 6.3.3", for example. For detailed information see the inside of the front cover flap. 332

* New in this catalogue.

Our product engineers will be happy to advise you in your choice of application-specific cables. 333


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:10 Seite 334

readycable® Content

... harnessed cables for Drive Technology ... ®

... harnessed cables for Drive Technology ... ®

®

chainflex readycable

®

chainflex readycable

Selection chart of igus® chainflex® cables (you can find the green number

readycable® Content

accordingly on the product pages of the respective manufacturers).

1

2

3

4

5

6

7

8

9

10

11

12

13

CF31

CF35.UL

CF38

CF210.UL

CF21.UL

CF270.UL.D

CF27.D

CF211 Mess

CF113.D

CF111.D

CF11.D

CFBUS

CF240.PUR

Class 5.3.2

Class 6.4.4

Class 7.4.4

Class 4.1.2

Class 5.3.2

Class 4.1.3

Class 6.3.3

Class 5.3.2

Class 6.3.3

Class 4.1.4

Class 6.4.4

Class 6.4.4

Class 5.2.3

PVC

TPE

TPE

PVC

PVC

PUR

PUR

PVC

PUR

TPE

TPE

TPE

PUR

Min. bending radius

7,5 x d

7,5 x d

7,5 x d

10 x d

7,5 x d

10 x d

7,5 x d

10 x d

10 x d

12 x d

10 x d

12,5 x d

10 - 12 x d

Travel distance [m]

100

400

400

unsupported

100

unsupported

100

100

100

unsupported

400

400

50

Technical information Class Outer jacket Shielded

Oil-resistant Oil-/coolantresistant Flame-retardant

Halogen-free

Notch-resistant

✔ ✔

✔ ✔

✔ ✔

✔ ✔ ✔

Hydrolysis-/ microbe-resistant

.

Temperature [°C]

-5 to +70

-35 to +90

-35 to +90

-5 to +70

-5 to +70

-20 to +80

-20 to +80

-5 to +70

-20 to +80

-35 to +100

-35 to +100

-35 to +70

-20 to +80

Nominal voltage [V]

600/1000

600/1000

600/1000

600/1000

600/1000

600/1000

600/1000

30

30

30

30

30

300/300

Color

Jet black

Jet black

Jet black

Pastel orange

Moss green

Pastel orange

Pastel orange

Silver gray

Yellow green

Yellow green

Yellow green

Red lilac

Silver gray

206

210

214

188

190

194

198

164

174

170

180

138

114

/CF31

/CF35

/CF38

/CF210UL

/CF21UL

/CF270ULD

/CF27D

/CF211M

/CF113D

/CF111D

/CF11D

/CFBUS

/CF240PUR

CE RoHS CleanRoom CEI UL/CSA + NFPA Desina More information Page wwww.igus.eu/en

334

335


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:11 Seite 336

readycable® Content

... harnessed cables for Drive Technology ... ®

... harnessed cables for Drive Technology ... ®

®

chainflex readycable

®

chainflex readycable

Selection chart of igus® chainflex® cables (you can find the green number

readycable® Content

accordingly on the product pages of the respective manufacturers).

14

15

16

17

18

19

20

21

22

23

24

25

26

CF211

CF113

CF11

CF130.UL

CF140.UL

CF5

CF6

CF170.D

CF77.UL.D

CF78.UL

CF9

CF10

CF9.UL

Class 5.3.2

Class 6.3.3

Class 6.4.4

Class 4.2.1

Class 4.2.1

Class 5.3.2

Class 5.3.2

Class 4.1.3

Class 5.3.3

Class 5.3.3

Class 7.4.4

Class 7.4.4

Class 6.4.4

PVC

PUR

TPE

PVC

PVC

PVC

PVC

PUR

PUR

PUR

TPE

TPE

TPE

Min. bending radius

7,5 x d

10 x d

6,8 x d

7,5 - 10 x d

7,5 - 15 x d

6,8 - 7,5 x d

6,8 - 7,5 x d

7,5 - 10 x d

6,8 - 7,5 x d

6,8 - 7,5 x d

5xd

5xd

5xd

Travel distance [m]

100

100

400

50

50

100

100

unsupported

100

100

400

400

400

Technical information Class Outer jacket Shielded

Oil-resistant

Oil-/coolantresistant Flame-retardant

✔ ✔

Halogen-free

Notch-resistant

Hydrolysis-/ microbe-resistant

✔ ✔

Temperature [°C]

-5 to +70

-20 to +80

-35 to +100

-5 to +70

-5 to +70

-5 to +70

-5 to +70

-35 to +80

-35 to +80

-35 to +80

-35 to +100

-35 to +100

-35 to +100

Nominal voltage [V]

300/300

300/300

300/300

300/500

300/500

300/500

300/500

300/500

300/500

300/500

300/500

300/500

300/500

Silver gray

Anthracite gray

Steel blue

Silver gray

Silver gray

Moss green

Moss green

Window gray

Window gray

Window gray

Steel blue

Steel blue

Steel blue

116

118

120

58

62

66

70

74

78

82

90

94

98

/CF211

/CF113

/CF11

/CF130

/CF140

/CF5

/CF6

/CF170D

/CF77

/CF78

/CF9

/CF10

/CF9UL

Color CE RoHS CleanRoom CEI UL/CSA + NFPA Desina More information Page wwww.igus.eu/en

336

337


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:11 Seite 338

readycable® Content

... Allen Bradley ... B&R ... Baumüller ... ... harnessed cables for Drive Technology ...

Allen Bradley/Rockwell – Selection table according to part numbers and sheath materials.

Baumüller – Selection table according to part numbers and sheath materials.

Basic cable

You will find your basic cable in the left column, the respective extension on the right.

Extension cable Outer jacket material page

ALLEN BRADLEY

PVC

PUR

Outer jacket material page

TPE

PVC

PUR

Basic cable

TPE

PUR

Outer jacket material page

TPE

PVC

PUR

356

356

356

356

356

326580 (15 m)

363

363

Servo cable 21 A

364

364

2090-XXNPMP-16SXX

356

356

356

326581 (20 m)

363

363

Servo cable 21 A

364

364

326582 (25 m)

363

363

Servo cable 21 A

364

364

Servo cable (PVC/PUR) 2090-XXNPMF-10SXX

356

356

326583 (30 m)

363

363

Servo cable 21 A

364

364

2090-XXNPMF-14SXX

356

356

326584 (35 m)

363

363

Servo cable 21 A

364

364

2090-XXNPMF-16SXX

356

356

326585 (40 m)

363

363

Servo cable 21 A

364

364

326586 (50 m)

364

364

Servo cable 21 A

364

364

326587 (75 m)

364

364

Servo cable 21 A

364

364

326588 (100 m)

364

364

Servo cable 21 A

364

364

326589 (5 m)

365

365

Servo cable 28 A

366

366

326591 (7 m)

365

365

Servo cable 28 A

366

366

326592 (10 m)

365

365

Servo cable 28 A

366

366

326593 (15 m)

365

365

Servo cable 28 A

366

366

356

356

Connection cable

Extension cable Outer jacket material page PVC

PUR

Outer jacket material page

TPE

PVC

PUR

TPE

Servo cable (PVC/PUR) 357

357

326594 (20 m)

365

365

Servo cable 28 A

366

366

i8BCMxxxx.1311A-0

357

357

326596 (25 m)

365

365

Servo cable 28 A

366

366

i8CMxxx.12-1

357

357

326597 (30 m)

365

365

Servo cable 28 A

366

366

i8CMxxx.12-3

357

357

326598 (35 m)

365

365

Servo cable 28 A

366

366

i8CMxxx.12-5

357

357

326599 (40 m)

365

365

Servo cable 28 A

366

366

326600 (5 m)

367

367

Servo cable 36 A

368

368

326601 (7 m)

367

367

Servo cable 36 A

368

368

326602 (10 m)

367

367

Servo cable 36 A

368

368

BAUMÜLLER

i8BCMxxxx.1111A-0

Resolver cable (PVC/PUR/TPE) i8BCRxxx.1111A-0

358

358

358

i8CRxxx.12-1

358

358

358

326603 (15 m)

367

367

Servo cable 36 A

368

368

i8BCExxxx.1111A-0

358

358

358

326604 (20 m)

367

367

Servo cable 36 A

368

368

i8CExxx.12-1

358

358

358

EnDat-cable (PVC/PUR/TPE)

326605 (25 m)

367

367

Servo cable 36 A

368

368

Baumüller – Selection table according to part numbers and sheath materials.

326606 (30 m)

367

367

Servo cable 36 A

368

368

You will find your basic cable in the left column, the respective extension on the right.

326607 (35 m)

367

367

Servo cable 36 A

368

368

Basic cable

326608 (40 m)

367

367

Servo cable 36 A

368

368

326609 (5 m)

369

369

Servo cable 50 A

369

369

326610 (7 m)

369

369

Servo cable 50 A

369

369

Extension cable Outer jacket material page PVC

PUR

359

359

Outer jacket material page

TPE

PVC

PUR

326611 (10 m)

369

369

Servo cable 50 A

369

369

360

360

326612 (15 m)

369

369

Servo cable 50 A

369

369

Servo cable (PVC/PUR) 324781 (5 m)

TPE

Servo cable (PVC/PUR)

356

2090-XXNPMP-14SXX

B&R – Selection table according to part numbers and sheath materials.

B&R

PVC

2090-XXNPMP-10SXX

2090-UXNBMP-18SXX

BAUMÜLLER

Extension cable Outer jacket material page

Power cable (PVC/PUR/TPE)

Brake cable (PVC/PUR)

338

readycable® Content

... Baumüller ... ... harnessed cables for Drive Technology ...

Servo cable 15 A

TPE

324782 (7 m)

359

359

Servo cable 15 A

360

360

326613 (20 m)

369

369

Servo cable 50 A

369

369

324783 (10 m)

359

359

Servo cable 15 A

360

360

326614 (25 m)

369

369

Servo cable 50 A

369

369

324784 (15 m)

359

359

Servo cable 15 A

360

360

326615 (30 m)

369

369

Servo cable 50 A

369

369

324785 (20m)

359

359

Servo cable 15 A

360

360

326616 (35 m)

369

369

Servo cable 50 A

369

369

324786 (25 m)

359

359

Servo cable 15 A

360

360

326617 (40 m)

369

369

Servo cable 50 A

369

369

324787 (30 m)

359

359

Servo cable 15 A

360

360

380967 (7 m)

361

361

Servo cable 20 A

362

362

324788 (35 m)

359

359

Servo cable 15 A

360

360

413410 (10 m)

361

361

Servo cable 20 A

362

362

324789 (40 m)

359

359

Servo cable 15 A

360

360

414840 (5 m)

361

361

Servo cable 20 A

362

362

324790 (50 m)

360

360

Servo cable 15 A

360

360

414841 (15 m)

361

361

Servo cable 20 A

362

362

324791 (75 m)

360

360

Servo cable 15 A

360

360

414842 (20 m)

361

361

Servo cable 20 A

362

362

324792 (100 m)

360

360

Servo cable 15 A

360

360

414843 (25 m)

361

361

Servo cable 20 A

362

362

326577 (5 m)

363

363

Servo cable 21 A

364

364

414846 (30 m)

361

361

Servo cable 20 A

362

362

326578 (7 m)

363

363

Servo cable 21 A

364

364

414848 (35 m)

361

361

Servo cable 20 A

362

362

326579 (10 m)

363

363

Servo cable 21 A

364

364

414849 (40 m)

361

361

Servo cable 20 A

362

362

339


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:11 Seite 340

readycable® Content

... Baumüller ... ... harnessed cables for Drive Technology ...

... Baumüller ... Beckhoff ... Berger Lahr... ...Control Techniques ... harnessed cables for Drive Technology ... Baumüller – Selection table according to part numbers and sheath materials.

You will find your basic cable in the left column, the respective extension on the right.

You will find your basic cable in the left column, the respective extension on the right.

Basic cable

Extension cable Outer jacket material page PVC

PUR

414850 (50 m)

362

362

414851 (75 m)

362

414852 (100 m)

362

369864 (3 m)

374

374

374

371494 (20 m)

374

374

378022 (50 m)

375

375

380358 (35 m)

375

382005 (45 m)

375

389807 (7 m) 389808 (9 m)

Outer jacket material page

TPE

PVC

PUR

TPE

Servo cable 20 A

362

362

362

Servo cable 20 A

362

362

Servo cable 20 A

362

ECN1313/EQN1325

375

375

375

374

ECN1313/EQN1325

375

375

375

375

ECN1313/EQN1325

375

375

375

375

375

ECN1313/EQN1325

375

375

375

375

375

ECN1313/EQN1325

375

375

375

374

374

374

ECN1313/EQN1325

375

375

375

374

374

374

ECN1313/EQN1325

375

375

375

391216 (40 m)

375

375

375

ECN1313/EQN1325

375

375

375

393889 (2 m)

374

374

374

ECN1313/EQN1325

375

375

375

393890 (8 m)

374

374

374

ECN1313/EQN1325

375

375

375

393891 (10 m)

374

374

374

ECN1313/EQN1325

375

375

393892 (15 m)

374

374

374

ECN1313/EQN1325

375

393893 (25 m)

375

375

375

ECN1313/EQN1325

375

393894 (30 m)

375

375

375

ECN1313/EQN1325

394014 (5 m)

374

374

374

ECN1313/EQN1325

198962 (3 m)

372

372

372

198963 (5 m)

372

372

198964 (8 m)

372

372

198965 (10 m)

372

198966 (15 m)

372

198967 (20 m) 198968 (25 m)

BAUMÜLLER

Baumüller – Selection table according to part numbers and sheath materials.

Outer jacket material page

Outer jacket material page

PUR

245484 (60 m)

371

371

371

362

246658 (3 m)

370

370

370

362

Beckhoff – Selection table according to part numbers and sheath materials.

Encoder cable (PVC/PUR/TPE)

TPE

PVC

PUR

TPE

Resolver / SKS / SKM

371

371

371

Resolver / SKS / SKM

371

371

371

Resolver cable (PVC/PUR/TPE)

You will find your basic cable in the left column, the respective extension on the right. Basic cable

Extension cable Outer jacket material page

Outer jacket material page

PVC

PUR

ZK4000-2111-xxxx

376

376

TPE

PVC

PUR

ZK4000-2112-xxxx

376

376

ZK4000-2711-xxxx

376

376

ZK4500-0023-xxxx

376

376

ZK4500-0024-xxxx

376

376

ZK4501-0023-xxxx

376

376

ZK4501-0024-xxxx

377

377

375

ZK4000-2610-xxxx

377

377

375

375

ZK4510-0020-xxxx

377

377

375

375

ZK4520-0020-xxxx

377

377

ZK4511-0020-xxxx

377

377

ZK4511-0020-xxxx

377

377

375

375

375

375

375

375

ZK4000-2210-xxxx

378

378

ZK4530-0010-xxxx

378

378

Pulse encoder

373

373

373

378

378

372

Pulse encoder

373

373

373

ZK1090-9191-xxxx

372

Pulse encoder

373

373

373

Berger Lahr/Schneider Electric – Selection table according to part numbers and sheath materials.

372

372

Pulse encoder

373

373

373

Basic cable

372

372

Pulse encoder

373

373

373

372

372

372

Pulse encoder

373

373

373

372

372

372

Pulse encoder

373

373

373

198969 (30 m)

372

372

372

Pulse encoder

373

373

373

208829 (40 m)

373

373

373

Pulse encoder

373

373

373

225360 (35 m)

372

372

372

Pulse encoder

373

373

373

TPE

BECKHOFF

Servo cable (PVC/PUR)

Encoder cable (PVC/PUR)

Resolver cable (PVC/PUR)

Pulse encoder cable (PVC/PUR/TPE)

ZK4531-0020-xxxx

Network cable EtherCAT (TPE)

BERGER LAHR

BAUMÜLLER

Extension cable PVC

Servo cable (PVC/PUR)

378 Extension cable Outer jacket material page PVC

PUR

Outer jacket material page

TPE

PVC

PUR

TPE

Servo cable (PVC/PUR) VW3M5101Rxxx

379

379

VW3M5102Rxxx

379

379

VW3M8101Rxxx

379

379

Resolver cable (PVC/PUR/TPE)

Resolver cable (PVC/PUR/TPE)

340

Basic cable

readycable® Content

379

370

370

370

Resolver / SKS / SKM

371

371

371

Control Techniques – Selection table according to part numbers and sheath materials.

239541 (8 m)

370

370

370

Resolver / SKS / SKM

371

371

371

Basic cable

239542 (10 m)

370

370

370

Resolver / SKS / SKM

371

371

371

239543 (15 m)

370

370

370

Resolver / SKS / SKM

371

371

371

239544 (20m)

370

370

370

Resolver / SKS / SKM

371

371

371

239545 (25 m)

370

370

370

Resolver / SKS / SKM

371

371

371

239546 (30 m)

371

371

371

Resolver / SKS / SKM

371

371

371

239547 (35 m)

371

371

371

Resolver / SKS / SKM

371

371

371

240520 (40 m)

371

371

371

Resolver / SKS / SKM

371

371

371

240521 (45 m)

371

371

371

Resolver / SKS / SKM

371

371

371

240522 (50 m)

371

371

371

Resolver / SKS / SKM

371

371

371

242954 (6 m)

370

370

370

Resolver / SKS / SKM

371

371

371

243379 (4 m)

370

370

370

Resolver / SKS / SKM

371

371

244033 (55 m)

371

371

371

Resolver / SKS / SKM

371

371

CONTROL TECHNIQUES

239540 (5 m)

Extension cable Outer jacket material page PVC

PUR

TPE

Outer jacket material page PVC

PUR

TPE

Power cable (PVC/TPE) PS B A A A XXX

380

380

PS B A A B XXX

380

380

PS B A B B XXX

380

380

PS B A F A XXX

380

380

PS B A F B XXX

380

380

PS B B A A XXX

380

380

PS B B A B XXX

380

380

371

PS B B B B XXX

380

380

371

PS B B F A XXX

380

380

341


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:11 Seite 342

... Control Techniques ... ... harnessed cables for Drive Technology ...

Control Techniques – Selection table according to part numbers and sheath materials. Basic cable

Extension cable Outer jacket material page PVC

PUR

TPE

Power cable (PVC/TPE) PS B B F B XXX

381

381

PS B C A B XXX

381

381

PS B C B B XXX

381

381

PS B C F B XXX

381

381

PS B D A B XXX

381

PS B D B B XXX

381

PS B D F B XXX PS B E A B XXX

Outer jacket material page PVC

PUR

TPE

Extension cable Outer jacket material page PVC

PUR

Outer jacket material page

TPE

PVC

PB B G G B XXX

384

Encoder cable (PVC/TPE) 384 384

381

SS B A H N XXX

384

384

381

Danaher Motion – Selection table according to part numbers and sheath materials.

381

381

Connection cable

381

381

PS B E B B XXX

381

381

PS B E F B XXX

381

381

PS B G A A XXX

380

380

102575 (5 m)

386

386

PS B G A B XXX

381

381

102576 (10 m)

386

386

PS B G B B XXX

381

381

102806 (15 m)

386

386

PS B G F A XXX

380

380

102807 (20 m)

386

386

PS B G F B XXX

381

381

102808 (25 m)

386

386

107473 (5 m)

386

386

Extension cable Outer jacket material page PVC

PUR

TPE

382

107474 (10 m)

386

386

PB B A A A XXX

382

382

107475 (15 m)

386

386

PB B A A B XXX

382

382

107476 (20 m)

387

387

PB B A B B XXX

382

382

107477 (25 m)

387

387

PB B A F A XXX

382

382

107485 (5 m)

387

387

PB B A F B XXX

383

382

107486 (10 m)

387

387

107487 (15 m)

387

387

107488 (20 m)

387

387

107489 (25 m)

387

387

200456 (5 m)

387

387

200457 (10 m)

387

387

200458 (15 m)

387

387

382

382 382

PB B B A B XXX

382

382

PB B B B B XXX

383

383

PB B B F A XXX

382

382

PB B B F B XXX

383

Outer jacket material page PVC

PUR

TPE

Power cable (PVC/TPE)

PB A A F B XXX

382

TPE

384

384

PB B B A A XXX

PUR

Servo cable (PVC/PUR)

384

DANAHER MOTION

CONTROL TECHNIQUES

Basic cable

SS B A H H XXX

Servo cable (PVC/PUR)

342

Control Techniques – Selection table according to part numbers and sheath materials.

SS B A H C XXX

PB B A G B XXX

readycable® Content

... Control Techniques ... Danaher Motion ... ... harnessed cables for Drive Technology ... CONTROL TECHNIQUES

readycable® Content

PB B B G B XXX

383

383

200459 (20 m)

387

387

PB B C A B XXX

383

383

200460 (25 m)

388

388

PB B C B B XXX

383

383

200468 (5 m)

388

388

PB B C F B XXX

383

383

200469 (10 m)

388

388

PB B C G B XXX

383

383

200470 (15 m)

388

388

PB B D A B XXX

383

383

200471 (20 m)

388

388

PB B D B B XXX

383

383

200472 (25 m)

388

388

PB B D F B XXX

383

383

200618 (5 m)

388

388

PB B D G B XXX

383

383

200619 (10 m)

388

388

PB B E A B XXX

383

383

200620 (15 m)

388

388

PB B E B B XXX

383

383

200621 (20 m)

388

388

PB B E F B XXX

383

383

200622 (25 m)

388

388

PB B E G B XXX

383

383

89918 (5 m)

390

392

PB B G A A XXX

382

382

89952 (10 m)

390

392

PB B G A B XXX

384

384

89953 (15 m)

390

392

PB B G B B XXX

384

384

89954 (20 m)

390

392

PB B G F A XXX

382

382

89956 (25 m)

390

392

PB B G F B XXX

384

384

89959 (5 m)

391

393

343


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:11 Seite 344

readycable® Content

... Danaher Motion ... ... harnessed cables for Drive Technology ...

Danaher Motion – Selection table according to part numbers and sheath materials. Connection cable

Danaher Motion – Selection table according to part numbers and sheath materials.

Extension cable Outer jacket material page PVC

PUR

TPE

Connection cable Outer jacket material page PVC

PUR

Extension cable Outer jacket material page

TPE

PVC

PUR

Power cable (PVC/TPE) 89960 (10 m)

391

393

89969 (25 m)

389

389

89962 (15 m)

391

393

89970 (10 m)

389

389

89964 (20 m)

391

393

89971 (15 m)

389

389

89966 (25 m)

391

393

89972 (20 m)

390

390

90083 (5 m)

390

392

90088 (5 m)

390

390

90084 (10 m)

390

392

90089 (10 m)

390

390

90085 (15 m)

390

392

90090 (15 m)

390

390

90086 (20 m)

390

392

90091 (20 m)

390

390

90087 (25 m)

390

392

90092 (25 m)

390

390

TPE

PVC

PUR

TPE

Signal cable (PVC/TPE)

390

390

102580 (10 m)

390

390

102809 (15 m)

390

390

102810 (20 m)

391

391

102811 (25 m)

391

391

107479 (5 m)

391

391

107480 (10 m)

391

391

107481 (15 m)

391

391

107482 (20 m)

391

391

84975 (20 m)

394

394

107483 (25 m)

391

391

85034 (5 m)

395

395

107491 (5 m)

391

391

85035 (10 m)

395

395

107492 (10 m)

392

392

85036 (15 m)

395

395

107493 (15 m)

392

392

85037 (20 m)

395

395

107494 (20 m)

392

392

85039 (5 m)

395

395

107495 (25 m)

392

392

85040 (10 m)

395

395

200462 (5 m)

392

392

85041 (15 m)

395

395

200463 (10 m)

392

392

85042 (20 m)

395

395

200464 (15 m)

392

392

87655 (25 m)

394

394

200465 (20 m)

392

392

90287 (5 m)

394

394

200466 (25 m)

392

392

91019 (10 m)

394

394

200474 (5 m)

393

393

91807 (20 m)

394

394

200475 (10 m)

393

393

91811 (15 m)

394

394

394

394

DANAHER MOTION

102579 (5 m)

107915 (5 m)

394

394

107916 (10 m)

394

394

107917 (15 m)

394

394

107918 (20 m)

394

394

107919 (25 m)

394

394

84972 (5 m)

394

394

84973 (10 m)

394

394

84974 (15 m)

394

394

200476 (15 m)

393

393

92205 (25 m)

200477 (20 m)

393

393

Elau/Schneider Electric – Selection table according to part numbers and sheath materials.

200478 (25 m)

393

393

Connection cable

200623 (5 m)

393

393

200624 (10 m)

393

393

200625 (15 m)

393

393

200626 (20 m)

393

393

200627 (25 m)

393

393

Extension cable Outer jacket material page PVC

PUR

TPE

Outer jacket material page PVC

PUR

TPE

Servo cable (PVC/PUR) ELAU

DANAHER MOTION

Outer jacket material page

Servo cable (PVC/PUR)

Servo cable (PVC/PUR)

344

readycable® Content

... Danaher Motion ... Elau ... ... harnessed cables for Drive Technology ...

E-MO-067

396

396

E-MO-111 SH-Motor 1.5

396

396

89957 (5 m)

389

389

E-MO-087

396

396

89961 (10 m)

389

389

E-MO-092

396

396

89963 (15 m)

389

389

E-MO-113 SH-Motor 2.5

396

396

89965 (20 m)

389

389

89967 (25 m)

389

389

89968 (5 m)

389

389

345


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:11 Seite 346

readycable® Content

... Elau ... Fagor ... FANUC ... ... harnessed cables for Drive Technology ...

Elau/Schneider Electric – Selection table according to part numbers and sheath materials.

Heidenhain – Selection table according to part numbers and sheath materials.

Connection cable

Connection cable

Extension cable

ELAU

Outer jacket material page PVC

PUR

Outer jacket material page

TPE

PVC

PUR

Extension cable Outer jacket material page

TPE

PVC

E-FB-060

397

397

352 960-xx

404

404

E-FB-071

397

397

352 962-xx

404

404

E-FB-080

397

397

352 963-xx

404

404

PVC

PUR

289 440-xx Outer jacket material page

TPE

PVC

PUR

TPE

405

405

298 399-xx

405

405

405

298 400-xx

405

405

298 402-xx

405

405

309 738-xx

405

405

309 774-xx

406

406

309 777-xx

406

406

309 778-xx

406

406

iXC-C2-D

398

398

iXC-C2-FN2

399

399

iXC-C2-H

398

398

iXC-C4-D

398

398

iXC-C8-F-C9

398

398

309 783-xx

405

405

iXC-C8-F-D

398

398

310 193-xx

406

406

iXC-C8-FN

399

399

310 197-xx

406

406

iEEC-x

398

398

310 199-xx

406

406

FANUC – Selection table according to part numbers and sheath materials.

323 897-xx

406

406

You will find your basic cable in the left column, the respective extension on the right.

324 544-xx

407

407

332 115-xx

407

407

335 077-xx

407

407

Basic cable

HEIDENHAIN

FAGOR

Path measurement cable (PUR/TPE)

Basic cable Outer jacket material page PVC

PUR

Outer jacket material page

TPE

PVC

PUR

TPE

336 376-xx

Power cable (PVC/PUR/TPE) Bending radius 10 x d

PVC

Bending radius 7,5 x d

405

405

354 411-xx

405

407

407

355 398-xx

407

407

LX660-8077-T261

400

400

400

LX660-8077-T261

400

360 472-xx

407

407

LX660-8077-T264

400

400

400

LX660-8077-T264

400

368 172-xx

406

406

LX660-8077-T265

400

400

400

LX660-8077-T265

400

533 627-xx

406

406

LX660-8077-T266

400

400

400

LX660-8077-T266

400

604 419-xx

405

405

LX660-8077-T267

400

400

400

LX660-8077-T267

400

Jetter – Selection table according to part numbers and sheath materials.

LX660-8077-T270

400

400

400

LX660-8077-T270

400

Basic cable

LX660-8077-T271

401

401

401

LX660-8077-T271

401

LX660-8077-T272

401

401

401

LX660-8077-T272

401

LX660-8077-T273

401

401

401

LX660-8077-T273

401

406

PVC

PUR

TPE

TPE

Outer jacket material page PVC

PUR

TPE

Power cable (PVC/PUR/TPE)

LX660-8077-T291

401

401

401

LX660-8077-T291

401

Kabel Nr. 26.1

408

408

408

LX660-8077-T292

401

401

401

LX660-8077-T292

401

Kabel Nr. 201

408

408

408

LX660-8077-T293

401

401

401

LX660-8077-T293

401

Kabel Nr. 203

408

408

LX660-8077-T296

402

402

402

LX660-8077-T296

402

LX660-8077-T298

402

402

402

LX660-8077-T298

402

LX660-8077-T300

402

402

402

LX660-8077-T300

402

Signal cable (PUR/TPE) Bending radius 12 x d

PUR

Extension cable Outer jacket material page

JETTER

FANUC

TPE

Adapter cable (PVC/PUR/TPE)

Extension cable Outer jacket material page

Outer jacket material page

Servo cable (PVC/PUR)

Fagor – Selection table according to part numbers and sheath materials.

346

PUR

Encoder cable (PVC/TPE)

Basic cable

readycable® Content

... Heidenhain ... Jetter ... ... harnessed cables for Drive Technology ...

408

Servo cable (PVC/PUR) Kabel Nr. 24.1

408

408

Kabel Nr. 202

408

408

Kabel Nr. 204

408

408

Resolver cable (PVC/PUR/TPE)

Bending radius 10 x d

LX660-4077-T296

403

403

LX660-4077-T296

403

Kabel Nr. 23

409

409

409

LX660-4077-T297

403

403

LX660-4077-T297

403

Kabel Nr. 423

409

409

409

LX660-4077-T302

403

403

LX660-4077-T302

403

Kabel Nr. 523

409

409

409

LX660-4077-T303

403

403

LX660-4077-T303

403

Kabel Nr. 723

409

409

409

LX660-4077-T319

403

403

LX660-4077-T319

403

347


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:11 Seite 348

readycable® Content

... Lenze ... ... harnessed cables for Drive Technology ...

Lenze – Selection table according to part numbers and sheath materials.

Lenze – Selection table according to part numbers and sheath materials.

You will find your basic cable in the left column, the respective extension on the right.

You will find your basic cable in the left column, the respective extension on the right.

Basic cable

Basic cable

Linking cable PVC

PUR

410

410

Outer jacket material page

TPE

PVC

PUR

411

411

TPE

Servo cable (PVC/PUR)

LENZE

EWLMxxxGMS-015C

EWLMxxxZM-015C

Linking cable Outer jacket material page

LENZE

Outer jacket material page

readycable® Content

... Lenze ... LTi DRiVES ... NUM ... ... harnessed cables for Drive Technology ...

PVC

PUR

Outer jacket material page

TPE

PVC

PUR

TPE

Fan cable (PVC/TPE) EWLLxxxGMS

417

417

EWLLxxxZM

417

417

EWLMxxxGMS-025

410

410

EWLMxxxZM-025

412

412

EYL002AxxxxL01A00

417

417

EYL002VxxxxL01J01

417

417

EYP0010AxxxxA00P01

410

410

EYP0010VxxxxM01P01

412

412

EYL002AxxxxL01A00

417

417

EYL002VxxxxA00J01

417

417

EYP0010AxxxxM01A00

410

410

EYP0010VxxxxM01P01

412

412

EYL002AxxxxL02A00

417

417

EYL002VxxxxL02J02

417

417

EYP0011AxxxxA00P01

410

410

EYP0011VxxxxM01P01

412

412

EYL002AxxxxL02A00

417

417

EYL002VxxxxA00J02

417

417

EYP0011AxxxxM01A00

410

410

EYP0011VxxxxM01P01

412

412

LTi DRiVES – Selection table according to part numbers and sheath materials.

EYP0012AxxxxA00P01

410

410

EYP0012VxxxxM01P01

412

412

You will find your basic cable in the left column, the respective extension on the right.

EYP0012AxxxxA00P02

410

410

EYP0012VxxxxM02P02

412

412

Basic cable

EYP0012AxxxxM01A00

410

410

EYP0012VxxxxM01P01

412

412

EYP0012AxxxxM02A00

411

411

EYP0012VxxxxM02P02

412

412

EYP0013AxxxxA00P02

411

411

EYP0013VxxxxM02P02

412

412

EYP0013AxxxxM02A00

411

411

EYP0013VxxxxM02P02

412

412

EYP0014AxxxxA00P03

411

411

EYP0014VxxxxM03P03

412

412

EYP0014AxxxxM03A00

411

411

EYP0014VxxxxM03P03

412

412

EYP0015AxxxxA00P03

411

411

EYP0015VxxxxM03P03

412

412

EYP0015AxxxxM03A00

411

411

EYP0015VxxxxM03P03

412

412

KGH2-KSxxx

419

419

KGH2-KSxxx

419

419

EYP0016AxxxxA00P03

411

411

EYP0016VxxxxM03P03

412

412

KGH3-KSxxx

419

419

KGH3-KSxxx

419

419

EYP0016AxxxxM03A00

411

411

EYP0016VxxxxM03P03

412

412

KGS2-KSxxx

LTI DRIVES

PVC

Encoder cable (PVC/TPE) EWLExxxZMST

413

Extension cable Outer jacket material page

EWLExxxGM-T

413

413

EWLExxxGX-T

413

413

413

EYF0018AxxxxA00S03

414

414

EYF0018AxxxxA00W02

414

414

EYF0018AxxxxF02S03

414

414

EYF0019VxxxxF02G02

415

415

EYF0018AxxxxF02W02

414

414

EYF0019VxxxxF02G02

415

415

EYF0019VxxxxA00G02

415

415

PUR

Outer jacket material page

TPE

PVC

PUR

KM3-KSxxx

418

418

KM3-KSxxx

418

418

KM3-KSxxx-24A

418

418

KM3-KSxxx-24A

418

418

KM3-KSxxx-63A

418

418

KM3-KSxxx-63A

418

418

Encoder cable (PVC/PUR/TPE)

419

419

KGS2-KSxxx

419

419

KRY2-CDF-KSxxx

419

419

419

KRY2-CDF-KSxxx

419

419

419

KRY2-KSxxx

419

419

419

KRY2-KSxxx

419

419

419

NUM – Selection table according to part numbers and sheath materials.

Feedback cable (PVC/TPE)

You will find your basic cable in the left column, the respective extension on the right. Basic cable

Extension cable Outer jacket material page PVC

PUR

Outer jacket material page

TPE

PVC

PUR

410

AGOFRU019LMxxx

410

410

AGOFRU018LMxxx

410

410

410

AGOFRU019LMxxx

410

410

414

414

414

EYF0020AxxxxF01S04

414

414

EYF0020VxxxxF01G01

415

415

AGOFRU018Mxxx

410

410

AGOFRU018Mxxx

410

410

EYF0020AxxxxF01S05

414

414

EYF0020VxxxxF01G01

415

415

AGOFRU019Mxxx

410

410

AGOFRU019Mxxx

410

410

EYF0020VxxxxA00G01

415

415

AGOFRU020Mxxx

410

410

AGOFRU020Mxxx

421

421

EYF0021AxxxxA00S03

414

414

EYF0021AxxxxF03S03

414

414

NUM

414

EYF0020AxxxxA00S05

Servo cable (PVC/PUR)

Encoder/Sensor cable (PVC/TPE) EYF0022VxxxxF03G03

415

415

AGOFRU029Mxxx

421

421

AGOFRU029Mxxx

421

421

EYF0022VxxxxF03G03

415

415

AGOFRU030Mxxx

421

421

AGOFRU030Mxxx

421

421

413

413

AGOFRU012Mxxx

421

421

421

Resolver cable (PVC/TPE) 413

EWLRxxxGX-T

413

413

TPE

Power cable (PVC/TPE) AGOFRU018LMxxx

EYF0020AxxxxA00S04

EWLRxxxGM-T

TPE

Servo cable (PVC/PUR)

EWLRxxxZMST

Fan cable (PVC/TPE) 421

AGOFRU012Mxxx

413

Decoder cable (PVC/TPE)

348

EYD0017AxxxxW01S01

416

416

EYD0017AxxxxW01S02

416

416

EYD0017AxxxxW03S01

416

416

EYD0017AxxxxW03S02

416

416

349


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:11 Seite 350

readycable® Content

... Omron ... Rexroth ... ... harnessed cables for Drive Technology ...

Omron – Selection table according to part numbers and sheath materials.

Rexroth – Selection table according to part numbers and sheath materials.

You will find your basic cable in the left column, the respective extension on the right.

You will find your basic cable in the left column, the respective extension on the right.

Basic cable

Basic cable

Extension cable Outer jacket material page PVC

PUR

Outer jacket material page

TPE

PVC

PUR

Connecting cables with adapter plugs Outer jacket material page

TPE

PVC

PUR

Power cable (PVC/TPE)

OMRON

R88A-CAWA-xxxS-DE

PVC

PUR

427

427

IKG4141

429

429

R88A-CAWCxxx

422

422

IKG4150

427

427

IKG4141

429

429

R88A-CAWCxxxS-E

422

422

IKG4155

427

427

IKG4141

429

429

R88A-CAWDxxxS

422

422

IKG4164

428

428

R88A-CAWDxxxS-E

422

422

IKG4167

428

428

IKG4161

429

429

R88A-CAWFxxxS-E

422

422

IKG4172

428

428

IKG4173

428

428

IKL0023

428

428

IKL0089

428

428

Encoder cable (PVC/TPE) JZSP-CHP800-xx-E

423

423

IKG4186

428

428

JZSP-CHP800-xx-ME

422

422

IKG4200

428

428

JZSP-CSP21-XX-E-G1

423

423

IKG4204

428

428

R88A-CRWA-xxxC-DE

423

423

IKL0001

425

425

R88A-CRWBxxxN

422

422

IKL0006

425

425

R88A-CRWBxxxN-E

422

422

IKL0011

425

425

IKL0021

425

425

JZSP-CHM000-xx-E

423

423

IKL0041

425

425

JZSP-CHM000-xx-ME

424

424

IKL0042

425

425

JZSP-CHM030-xx-E

423

423

IKL0061

425

425

IKL0081

425

425

IKL0101

425

425

IKL0121

425

425

IKL0161

426

425

IKL0168

428

428

RKL4300

429

429

RKL4304

432

432

RKL4301

429

429

RKL4304

432

432

RKL4302

429

429

RKL4305

432

432

RKL4303

429

429

RKL4305

432

432

RKL4306

430

430

RKL4311

432

432

RKL4307

430

430

RKL4311

432

432

424

424

JZSP-CSM22-xx-E-G1

423

423

R88A-CAWCxxxB-E

423

423

R88A-CAWExxxB

424

424

REXROTH

JZSP-CHM030-xx-ME

You will find your basic cable in the left column, the respective extension on the right. Basic cable

Connecting cables with adapter plugs Outer jacket material page PVC

PUR

Outer jacket material page

TPE

TPE

Power cable (PVC/PUR) IKG4147

Rexroth – Selection table according to part numbers and sheath materials.

PVC

PUR

Power cable (PVC/PUR)

REXROTH

Outer jacket material page

TPE

422

Control cable (PVC/PUR)

350

readycable® Content

... Rexroth ... ... harnessed cables for Drive Technology ...

TPE

IKG0331

426

426

IKG0332

428

428

RKL4308

430

430

RKL4312

432

432

IKG4008

426

426

IKG4006

428

428

RKL4309

430

430

RKL4312

432

432

IKG4009

426

426

IKG4006

428

428

RKL4310

430

430

RKL4312

432

432

IKG4017

426

426

IKG4006

428

428

RKL4313

430

430

RKL4316

432

432

IKG4018

426

426

RKL4314

430

430

RKL4316

432

432

IKG4020

426

426

RKL4315

430

430

RKL4316

432

432

IKG4055

426

426

RKL4317

430

430

RKL4319

432

432

IKG4060

426

426

RKL4318

430

430

RKL4319

432

432

IKG4067

426

426

IKG4061

429

429

RKL4320

431

431

IKG4070

426

426

IKG4061

429

429

RKL4321

431

431

RKL4336

432

432

IKG4072

426

426

IKG4074

429

429

RKL4322

431

431

IKG4087

427

427

IKG4081

429

429

RKL4323

431

431

RKL4338

432

432

IKG4090

427

427

IKG4081

429

429

RKL4324

431

431

IKG4100

427

427

RKL4325

431

431

IKG4103

427

427

RKL4326

431

431

RKL4336

432

432

IKG4107

427

427

RKL4327

431

431

IKG4118

427

427

RKL4328

431

431

RKL4338

432

432

IKG4119

427

427

RKL4329

431

431

351


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:11 Seite 352

readycable® Content

... Rexroth ... SEW ... ... harnessed cables for Drive Technology ...

Rexroth – Selection table according to part numbers and sheath materials.

SEW – Selection table according to part numbers and sheath materials.

You will find your basic cable in the left column, the respective extension on the right.

You will find your basic cable in the left column, the respective extension on the right.

Basic cable

Connection cable

Connecting cables with adapter plugs Outer jacket material page PVC

PUR

RKL4330

432

432

RKL4331

432

432

Outer jacket material page

TPE

PVC

PUR

433

433

Extension cable Outer jacket material page

TPE

PVC

PUR

0199 1906

437

437

0199 1922

437

0199 1949

437

433

IKS0232

IKS0251

433

433

IKS0255

434

IKS0253

433

IKS0255

434

IKS0259

433

434

434

PUR

0199 2007

438

438

437

0199 2023

438

438

437

0199 204X

438

438

0199 1965 0199 1981

437

437

0199 2066

438

438

437

437

0199 2082

438

438

1332 4861

437

437

0593 6500

438

438

439

439

IKS0303

434

439

0593 9682

0199 3194

439

0199 5413

433

433

IKS0315

433

433

0199 4875

439

0199 5421

439

IKS0374

433

433

1332 4535

439

0199 5391

439

IKS4001

433

433

1332 4551

IKS4002

433

433

1332 7429

IKS4020

433

433

IKS4038

433

433

IKS4041

433

433

IKS4042

434

434

IKS4066

434

434

IKS4103

434

IKS4142 IKS4314

IKS4376

434

0198 9308

IKS0301

435

435

439 439

1332 7437

0199 5405

439

0199 5413

439

439

You will find your basic cable in the left column, the respective extension on the right. IKS4151 / IKS 4153

435

435

434

IKS4322

435

435

434

434

IKS4376

435

435

434

434

IKS4374

434

IKS4375

434

IKS4384

434

434

IKS4389

434

434

RKG0014

435

435

RKG0020

435

435

RKG0026

435

RKG0028

435

RKG4200

435

Basic cable

Extension cable Outer jacket material page PVC

PUR

6FX8002-5CA01

440

440

434

6FX8002-5CA11

434

6FX8002-5CA21

Outer jacket material page

TPE

PVC

PUR

TPE

Power cable (PVC/PUR/TPE) 440

6FX8002-5CA05

441

441

440

440

6FX8002-5CA15

441

441

440

440

6FX8002-5CA28

442

442

6FX8002-5CA23

440

440

6FX8002-5CX28

442

442

6FX8002-5CA31

440

440

6FX8002-5CA38

442

442

435

6FX8002-5CA41

440

440

6FX8002-5CA48

442

442

435

6FX8002-5CA51

440

440

6FX8002-5CA58

442

442

435

435

6FX8002-5CA61

440

440

6FX8002-5CA68

442

442

435

435

6FX8002-5CS01

441

441

435

435

6FX8002-5CS21

441

441

6FX8002-5CS31

441

441

6FX8002-5DA01

443

443

6FX8002-5DA05

444

444

6FX8002-5DA11

443

443

6FX8002-5DA15

444

444

6FX8002-5DA21

443

443

6FX8002-5DA28

445

445

RKG4201

435

435

435

SIEMENS

.

Servo cable (PVC/PUR)

You will find your basic cable in the left column, the respective extension on the right. Connection cable

Extension cable Outer jacket material page PVC

PUR

0199 1809

436

436

0199 1825 0199 1841

Outer jacket material page

TPE

PVC

PUR

TPE

Power cable (PVC/PUR/TPE) SEW

439

Siemens – Selection table according to part numbers and sheath materials.

SEW – Selection table according to part numbers and sheath materials.

352

TPE

Encoder cable (PVC/PUR)

433

IKS0262

REXROTH

434

SEW

433

TPE

Servo cable (PVC/PUR)

Encoder cable (PVC/PUR/TPE) IKS0230

Outer jacket material page PVC

Power cable (PVC/PUR) RKL4340

readycable® Content

... SEW ... Siemens ... ... harnessed cables for Drive Technology ...

6FX8002-5DA23

444

444

6FX8002-5DX28

445

445

436

0199 5502

436

436

6FX8002-5DA31

443

443

6FX8002-5DA38

445

445

436

436

0199 5529

436

436

6FX8002-5DA33

444

444

6FX8002-5DX38

445

445

436

436

0199 5545

436

436

6FX8002-5DA41

443

443

6FX8002-5DA48

445

445

0199 1868

436

436

0199 5561

436

436

6FX8002-5DA43

444

444

6FX8002-5DX48

445

445

0199 1884

436

436

199 558 8

437

437

6FX8002-5DA51

443

443

6FX8002-5DA58

445

445

0590 4773

436

436

0590 3610

437

437

6FX8002-5DA61

443

443

6FX8002-5DA68

445

445

6FX8002-5DS01

444

444

6FX8002-5DS21

444

444

6FX8002-5DS61

444

444

353


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:11 Seite 354

readycable® Content

readycable® Content

... Siemens ... Stöber ... ... harnessed cables for Drive Technology ...

Siemens – Selection table according to part numbers and sheath materials. You will find your basic cable in the left column, the respective extension on the right. Basic cable

Extension cable Outer jacket material page PVC

PUR

Outer jacket material page

TPE

PVC

PUR

TPE

Signal cable (PVC/PUR/TPE)

SIEMENS

6FX8002-1DC00

449

6FX8002-2AD00

446

446

6FX8002-2AD04

448

448

6FX8002-2AH00

447

447

6FX8002-2AH04

448

448

6FX8002-2CA11

446

446

6FX8002-2CB54

448

448

6FX8002-2CA15

446

446

6FX8002-2CA54

448

448

6FX8002-2CA31

446

446

6FX8002-2CA34

448

448

6FX8002-2CA51

446

446

6FX8002-2CA54

448

448

6FX8002-2CA71

446

446

6FX8002-2CB31

446

6FX8002-2CB34

448

6FX8002-2CB51

446

446

6FX8002-2CC14

448

448

6FX8002-2CC11

446

446

6FX8002-2CB54

448

448

6FX8002-2CD01

447

447

6FX8002-2CB54

448

448

6FX8002-2CF01

447

447

6FX8002-2CF02

447

447

6FX8002-2CF04

448

448

6FX8002-2CG00

447

447

6FX8002-2CB54

448

448

6FX8002-2CH00

447

447

6FX8002-2AD04

448

448

6FX8002-2CK00

447

447

6FX8002-2CL00

447

6FX8002-2EQ14

449

449

6FX8002-2DC10

447

447 449

6FX8002-2DC20

449

6FX8002-2EQ00

448

448

6FX8002-2EQ10

448

448

Stöber – Selection table according to part numbers and sheath materials. Basic cable

Extension cable Outer jacket material page PVC

PUR

TPE

Outer jacket material page PVC

PUR

TPE

STÖBER

Servo cable (PVC/PUR)

354

Gr.1-Motor-1,0mm²

450

450

Gr.1-Motor-1,5mm²

450

450

Gr.1-Motor-2,5mm²

450

450

Gr.1-Motor-4,0mm²

450

450

Gr.1,5-Motor-4,0mm²

450

450

Gr.1,5-Motor-6,0mm²

450

450

Gr.1,5-Motor-10,0mm²

450

450

Encoder cable (PVC/PUR/TPE) Encoder ED/EK iSDS4000

451

Encoder ES iSDS4000

451

451

451

451

Encoder HTL

451

451

451

Encoder iMDS5000

451

451

451

Resolver iMDS5000

451

451

451

Resolver iSDS4000

451

451

451

355


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:11 Seite 356

Allen Bradley readycable® PVC/PUR/TPE

Allen Bradley harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

B&R harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Allen Bradley standard (PVC-/PUR-/TPE-Power cable) Jacket

Manufacturer

material

Part No.

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

26

B&R readycable® PVC/PUR/TPE

Page 334-337

Harnessed according to B&R standard (PVC-/PUR-Servo cable) Page

bending

334

radius [x d]

to 337

Basic cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø

Minimum

Page

bending

334

radius [x d]

to 337

13,5

10

4

[mm]

Basic cable

2090-XXNPMP-16SXX

PVC

MAT9761710

(4 G 1,5)C

10,5

7,5

1

i8CMxxx.12-1

PVC

2090-XXNPMP-16SXX

PUR

MAT9961716

(4 G 1,5)C

2090-XXNPMP-16SXX

TPE

MAT9961701

(4 G 1,5)C

2090-XXNPMP-16SXX

TPE

MAT9961713

(4 G 1,5)C

2090-XXNPMP-14SXX

PVC

MAT9761711

(4 G 2,5)C

2090-XXNPMP-14SXX

PUR

MAT9961717

(4 G 2,5)C

2090-XXNPMP-14SXX

TPE

MAT9961702

(4 G 2,5)C

2090-XXNPMP-14SXX

TPE

MAT9961714

2090-XXNPMP-10SXX

PVC

MAT9761712

2090-XXNPMP-10SXX

PUR

2090-XXNPMP-10SXX

TPE

2090-XXNPMP-10SXX

9,0

10

6

i8CMxxx.12-1

PVC

MAT9610001

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

9,5

7,5

2

i8CMxxx.12-1

PUR

MAT9850101

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

9,5

7,5

3

i8CMxxx.12-1

PUR

MAT9600001

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

12,0

7,5

1

i8CMxxx.12-3

PVC

MAT9750102

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

11,0

10

6

i8CMxxx.12-3

PVC

MAT9610002

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

11,5

7,5

2

i8CMxxx.12-3

PUR

MAT9850102

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

(4 G 2,5)C

11,5

7,5

3

i8CMxxx.12-3

PUR

MAT9600002

(4 G 4,0+2x(2x1,5)C)C

18,0

7,5

7

(4 G 6,0)C

16,0

7,5

1

MAT9961718

(4 G 6,0)C

14,5

10

6

MAT9961703

(4 G 6,0)C

16,0

7,5

2

TPE

MAT9961715

(4 G 6,0)C

16,0

7,5

3

i8BCMxxxx.1111A-0

PVC

MAT9750104

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

i8BCMxxxx.1111A-0

PVC

MAT9610010

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

i8BCMxxxx.1111A-0

PUR

MAT9850104

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

i8BCMxxxx.1111A-0

PUR

MAT9600010

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

Harnessed according to Allen Bradley standard (PVC-/PUR-Servo cable)

Basic cable MAT9711728

MAT9750101

(4 G 1,5+2x(2x0,75)C)C

Basic cable

i8BCMxxxx.1311A-0

PVC

MAT9750105

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

12,0

10

4

i8BCMxxxx.1311A-0

PVC

MAT9610011

(4 G 4,0+2x(2x1,5)C)C

14,5

7,5

5

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

i8BCMxxxx.1311A-0

PUR

MAT9850105

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

(4 G 1,5+(2x1,5)C)C

12,0

10

6

i8BCMxxxx.1311A-0

PUR

MAT9600011

(4 G 4,0+2x(2x1,5)C)C

14,0

7,5

7

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

i8CMxxx.12-5

PVC

MAT9610003

(4 G 10,0+2x(2x1,5)C)C

24,0

7,5

5

(4 G 2,5+(2x1,5)C)C

13,5

10

4

i8CMxxx.12-5

PUR

MAT9850103

(4 G 10,0+2x(2x1,5)C)C

22,0

10

6

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

i8CMxxx.12-5

PUR

MAT9600003

(4 G 10,0+2x(2x1,5)C)C

23,5

7,5

7

(4 G 2,5+(2x1,5)C)C

13,5

10

6

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

(4 G 6,0+(2x1,5)C)C

16,5

10

4

(4 G 6,0+(2x1,5)C)C

18,0

7,5

5

(4 G 6,0+(2x1,5)C)C

16,5

10

6

17,5

7,5

7

7,5-15

18

2090-XXNPMF-16SXX

PVC

(4 G 1,5+(2x1,5)C)C

2090-XXNPMF-16SXX

PVC

MAT9961720

2090-XXNPMF-16SXX

PUR

MAT9811724

2090-XXNPMF-16SXX

PUR

MAT9851706

2090-XXNPMF-14SXX

PVC

MAT9711729

2090-XXNPMF-14SXX

PVC

MAT9961721

2090-XXNPMF-14SXX

PUR

MAT9811725

2090-XXNPMF-14SXX

PUR

MAT9851707

2090-XXNPMF-10SXX

PVC

MAT9711730

2090-XXNPMF-10SXX

PVC

MAT9961722

2090-XXNPMF-10SXX

PUR

MAT9811726

2090-XXNPMF-10SXX

PUR

MAT9851708

(4 G 6,0+(2x1,5)C)C

Harnessed according to Allen Bradley standard (PVC-/PUR-Brake cable)

Basic cable 2090-UXNBMP-18SXX

PVC

MAT9711727

(3 G 0,75)C

8,5

2090-UXNBMP-18SXX

PVC

MAT9961719

(3 G 0,75)C

8,0

7,5

20

2090-UXNBMP-18SXX

PUR

MAT9811705

(3 G 0,75)C

8,0

6,8-7,5

23

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 356

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

357


CF21.UL (PVC) / CF27.D (PUR) /CF211 Daten (PVC) / CF11(TPE) / CF211 Mess (PVC) / CF11.D (TPE)

EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:11 Seite 358

B&R readycable® PVC/PUR/TPE

B&R harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

Baumüller harnessed drive cables ... optionally with PVC-/PUR-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to B&R standard (PVC-/PUR-/TPE-Resolver cable) Jacket

Manufacturer

material

Part No.

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

Page

bending

334

radius [x d]

to 337

[mm]

Basic cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø

Minimum

Page

bending

334

radius [x d]

to 337

13,5

10

4

[mm]

15 A-Basic cable

i8BCRxxx.1111A-0

PVC

MAT9640010

(3 x (2 x 0,25))C

7,0

10

14

324781 (5 m)

PVC

i8BCRxxx.1111A-0

PUR

MAT9840102

(3 x (2 x 0,25))C

8,5

10

15

324781 (5 m)

PVC

MAT9295001

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

i8BCRxxx.1111A-0

TPE

MAT9630010

(3 x (2 x 0,25))C

8,0

10

16

324781 (5 m)

PUR

MAT9850201

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

i8CRxxx.12-1

PVC

MAT9640001

(3x(2x0,25))C

7,0

10

14

324781 (5 m)

PUR

MAT9296001

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

i8CRxxx.12-1

PUR

MAT9840101

(3 x (2 x 0,25))C

8,5

10

15

324782 (7 m)

PVC

MAT9750202

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

TPE

MAT9630001

(3x(2x0,25))C

8,0

10

16

324782 (7 m)

PVC

MAT9295002

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

324782 (7 m)

PUR

MAT9850202

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

324782 (7 m)

PUR

MAT9296002

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

324783 (10 m)

PVC

MAT9750203

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

i8CRxxx.12-1

Harnessed according to B&R standard (PVC-/PUR-/TPE-EnDat-cable)

Basic cable

MAT9750201

(4 G 1,5+2x(2x0,75)C)C

324783 (10 m)

PVC

MAT9295003

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

8

324783 (10 m)

PUR

MAT9850203

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

10

9

324783 (10 m)

PUR

MAT9296003

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

10

11

324784 (15 m)

PVC

MAT9750204

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

9,0

10

8

324784 (15 m)

PVC

MAT9295004

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

9,0

10

9

324784 (15 m)

PUR

MAT9850204

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

10

11

324784 (15 m)

PUR

MAT9296004

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

324785 (20 m)

PVC

MAT9750205

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

324785 (20 m)

PVC

MAT9295005

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

324785 (20 m)

PUR

MAT9850205

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

324785 (20 m)

PUR

MAT9296005

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

324786 (25 m)

PVC

MAT9750206

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

324786 (25 m)

PVC

MAT9295006

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

324786 (25 m)

PUR

MAT9850206

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

324786 (25 m)

PUR

MAT9296006

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

324787 (30 m)

PVC

MAT9750207

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

324787 (30 m)

PVC

MAT9295007

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

324787 (30 m)

PUR

MAT9850207

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

324787 (30 m)

PUR

MAT9296007

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

324788 (35 m)

PVC

MAT9750208

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

324788 (35 m)

PVC

MAT9295008

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

324788 (35 m)

PUR

MAT9850208

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

324788 (35 m)

PUR

MAT9296008

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

324789 (40 m)

PVC

MAT9750209

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

324789 (40 m)

PVC

MAT9295009

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

324789 (40 m)

PUR

MAT9850209

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

324789 (40 m)

PUR

MAT9296009

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

i8BCExxxx.1111A-0

PVC

MAT9670002

(5x(2x0,14)+2x0,5)C

9,0

10

i8BCExxxx.1111A-0 i8BCExxxx.1111A-0

PUR

MAT9820102

(5x(2x0,14)+2x0,5)C

9,0

TPE

MAT9660002

(5x(2x0,14)+2x0,5)C

9,5

i8CExxx.12-1

PVC

MAT9670001

(5x(2x0,14)+2x0,5)C

i8CExxx.12-1

PUR

MAT9820101

(5x(2x0,14)+2x0,5)C

i8CExxx.12-1

TPE

MAT9660001

(5x(2x0,14)+2x0,5)C

9,5

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 358

Page 334-337

Harnessed according to Baumüller standard (PVC-/PUR-Servo cable)

Minimum

ø

26

Baumüller readycable® PVC/PUR

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

359


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:11 Seite 360

Baumüller readycable® PVC/PUR

Baumüller harnessed drive cables ... optionally with PVC-/PUR-jacket

Baumüller harnessed drive cables ... optionally with PVC-/PUR-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Baumüller standard (PVC-/PUR-Servo cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Page 334-337

Harnessed according to Baumüller standard (PVC-/PUR-Servo cable)

Minimum

Page

bending

334

radius [x d]

to 337

15 A-Basic cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø

Minimum

Page

bending

334

radius [x d]

to 337

15,5

10

4

[mm]

20 A-Basic cable

324790 (50 m)

PVC

MAT9750210

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

414840 (5 m)

PVC

324790 (50 m)

PVC

MAT9295010

324790 (50 m)

PUR

MAT9850210

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

414840 (5 m)

PVC

MAT9295020

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

414840 (5 m)

PUR

MAT9850214

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

324790 (50 m)

PUR

MAT9296010

324791 (75 m)

PVC

MAT9750211

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

414840 (5 m)

PUR

MAT9296020

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

380967 (7 m)

PVC

MAT9750215

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

324791 (75 m)

PVC

MAT9295011

324791 (75 m)

PUR

MAT9850211

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

380967 (7 m)

PVC

MAT9295021

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

380967 (7 m)

PUR

MAT9850215

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

324791 (75 m)

PUR

MAT9296011

324792 (100 m)

PVC

MAT9750212

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

380967 (7 m)

PUR

MAT9296021

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

413410 (10 m)

PVC

MAT9750216

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

324792 (100 m)

PVC

MAT9295012

324792 (100 m)

PUR

MAT9850212

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

413410 (10 m)

PVC

MAT9295022

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

413410 (10 m)

PUR

MAT9850216

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

324792 (100 m)

PUR

MAT9296012

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

413410 (10 m)

PUR

MAT9296022

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

414841 (15 m)

PVC

MAT9750217

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

414841 (15 m)

PVC

MAT9295023

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

414841 (15 m)

PUR

MAT9850217

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

15 A-Extension cable

MAT9750214

(4 G 2,5+2x(2x1,5)C)C

PVC

MAT9750213

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

414841 (15 m)

PUR

MAT9296023

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

PVC

MAT9297001

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

414842 (20 m)

PVC

MAT9750218

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

PUR

MAT9850213

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

414842 (20 m)

PVC

MAT9295024

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

PUR

MAT9298001

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

414842 (20 m)

PUR

MAT9850218

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

414842 (20 m)

PUR

MAT9296024

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

414843 (25 m)

PVC

MAT9750219

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

414843 (25 m)

PVC

MAT9295025

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

414843 (25 m)

PUR

MAT9850219

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

414843 (25 m)

PUR

MAT9296025

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

414846 (30 m)

PVC

MAT9750220

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

414846 (30 m)

PVC

MAT9295026

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

414846 (30 m)

PUR

MAT9850220

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

414846 (30 m)

PUR

MAT9296026

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

414848 (35 m)

PVC

MAT9750221

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

414848 (35 m)

PVC

MAT9295027

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

414848 (35 m)

PUR

MAT9850221

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

414848 (35 m)

PUR

MAT9296027

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

414849 (40 m)

PVC

MAT9750222

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

414849 (40 m)

PVC

MAT9295028

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

414849 (40 m)

PUR

MAT9850222

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

414849 (40 m)

PUR

MAT9296028

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 360

26

Baumüller readycable® PVC/PUR

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

361


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:11 Seite 362

Baumüller readycable® PVC/PUR

Baumüller harnessed drive cables ... optionally with PVC-/PUR-jacket

Baumüller harnessed drive cables ... optionally with PVC-/PUR-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Baumüller standard (PVC-/PUR-Servo cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Page 334-337

Harnessed according to Baumüller standard (PVC-/PUR-Servo cable)

Minimum

Page

bending

334

radius [x d]

to 337

20 A-Basic cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø

Minimum

Page

bending

334

radius [x d]

to 337

15,5

10

4

[mm]

21 A-Basic cable

414850 (50 m)

PVC

MAT9750223

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

326577 (5 m)

PVC

414850 (50 m)

PVC

MAT9295029

414850 (50 m)

PUR

MAT9850223

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

326577 (5 m)

PVC

MAT9295040

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

326577 (5 m)

PUR

MAT9850227

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

414850 (50 m)

PUR

MAT9296029

414851 (75 m)

PVC

MAT9750224

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

326577 (5 m)

PUR

MAT9296040

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

326578 (7 m)

PVC

MAT9295041

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

414851 (75 m)

PVC

MAT9295030

414851 (75 m)

PUR

MAT9850224

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

326578 (7 m)

PVC

MAT9750228

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

326578 (7 m)

PUR

MAT9850228

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

414851 (75 m)

PUR

MAT9296030

414852 (100 m)

PVC

MAT9750225

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

326578 (7 m)

PUR

MAT9296041

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

326579 (10 m)

PVC

MAT9295042

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

414852 (100 m)

PVC

MAT9295031

414852 (100 m)

PUR

MAT9850225

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

326579 (10 m)

PVC

MAT9750229

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

326579 (10 m)

PUR

MAT9850229

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

414852 (100 m)

PUR

MAT9296031

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

326579 (10 m)

PUR

MAT9296042

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

326580 (15 m)

PVC

MAT9750230

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

326580 (15 m)

PVC

MAT9295043

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

326580 (15 m)

PUR

MAT9850230

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

20 A-Extension cable

MAT9750227

(4 G 2,5+2x(2x1,5)C)C

PVC

MAT9750226

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

326580 (15 m)

PUR

MAT9296043

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

PVC

MAT9297020

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

326581 (20 m)

PVC

MAT9750231

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

PUR

MAT9850226

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

326581 (20 m)

PVC

MAT9295044

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

PUR

MAT9298020

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

326581 (20 m)

PUR

MAT9850231

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

326581 (20 m)

PUR

MAT9296044

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

326582 (25 m)

PVC

MAT9750232

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

326582 (25 m)

PVC

MAT9295045

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

326582 (25 m)

PUR

MAT9850232

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

326582 (25 m)

PUR

MAT9296045

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

326583 (30 m)

PVC

MAT9750233

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

326583 (30 m)

PVC

MAT9295046

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

326583 (30 m)

PUR

MAT9850233

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

326583 (30 m)

PUR

MAT9296046

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

326584 (35 m)

PVC

MAT9750234

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

326584 (35 m)

PVC

MAT9295047

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

326584 (35 m)

PUR

MAT9850234

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

326584 (35 m)

PUR

MAT9296047

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

326585 (40 m)

PVC

MAT9750235

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

326585 (40 m)

PVC

MAT9295048

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

326585 (40 m)

PUR

MAT9850235

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

326585 (40 m)

PUR

MAT9296048

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 362

26

Baumüller readycable® PVC/PUR

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

363


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:11 Seite 364

Baumüller readycable® PVC/PUR

Baumüller harnessed drive cables ... optionally with PVC-/PUR-jacket

Baumüller harnessed drive cables ... optionally with PVC-/PUR-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Baumüller standard (PVC-/PUR-Servo cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Page 334-337

Harnessed according to Baumüller standard (PVC-/PUR-Servo cable)

Minimum

Page

bending

334

radius [x d]

to 337

21 A-Basic cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø

Minimum

Page

bending

334

radius [x d]

to 337

17,0

10

4

[mm]

28 A-Basic cable

326586 (50 m)

PVC

MAT9750236

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

326589 (5 m)

PVC

326586 (50 m)

PVC

MAT9295049

326586 (50 m)

PUR

MAT9850236

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

326589 (5 m)

PVC

MAT9295060

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

326589 (5 m)

PUR

MAT9850240

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

326586 (50 m)

PUR

MAT9296049

326587 (75 m)

PVC

MAT9750237

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

326589 (5 m)

PUR

MAT9296060

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

326591 (7 m)

PVC

MAT9750241

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

326587 (75 m)

PVC

MAT9295050

326587 (75 m)

PUR

MAT9850237

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

326591 (7 m)

PVC

MAT9295061

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

326591 (7 m)

PUR

MAT9850241

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

326587 (75 m)

PUR

MAT9296050

326588 (100 m)

PVC

MAT9750238

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

326591 (7 m)

PUR

MAT9296061

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

326592 (10 m)

PVC

MAT9750242

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

326588 (100 m)

PVC

MAT9295051

326588 (100 m)

PUR

MAT9850238

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

326592 (10 m)

PVC

MAT9295062

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

326592 (10 m)

PUR

MAT9850242

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

326588 (100 m)

PUR

MAT9296051

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

326592 (10 m)

PUR

MAT9296062

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

326593 (15 m)

PVC

MAT9750243

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

326593 (15 m)

PVC

MAT9295063

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

326593 (15 m)

PUR

MAT9850243

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

21 A-Extension cable

MAT9750240

(4 G 4,0+2x(2x1,5)C)C

PVC

MAT9750239

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

326593 (15 m)

PUR

MAT9296063

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

PVC

MAT9297040

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

326594 (20 m)

PVC

MAT9750244

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

PUR

MAT9850239

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

326594 (20 m)

PVC

MAT9295064

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

PUR

MAT9298040

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

326594 (20 m)

PUR

MAT9850244

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

326594 (20 m)

PUR

MAT9296064

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

326596 (25 m)

PVC

MAT9750245

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

326596 (25 m)

PVC

MAT9295065

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

326596 (25 m)

PUR

MAT9850245

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

326596 (25 m)

PUR

MAT9296065

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

326597 (30 m)

PVC

MAT9750246

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

326597 (30 m)

PVC

MAT9295066

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

326597 (30 m)

PUR

MAT9850246

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

326597 (30 m)

PUR

MAT9296066

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

326598 (35 m)

PVC

MAT9750247

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

326598 (35 m)

PVC

MAT9295067

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

326598 (35 m)

PUR

MAT9850247

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

326598 (35 m)

PUR

MAT9296067

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

326599 (40 m)

PVC

MAT9750248

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

326599 (40 m)

PVC

MAT9295068

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

326599 (40 m)

PUR

MAT9850248

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

326599 (40 m)

PUR

MAT9296068

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 364

26

Baumüller readycable® PVC/PUR

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

365


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:11 Seite 366

Baumüller readycable® PVC/PUR

Baumüller harnessed drive cables ... optionally with PVC-/PUR-jacket

Baumüller harnessed drive cables ... optionally with PVC-/PUR-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Baumüller standard (PVC-/PUR-Servo cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Page 334-337

Harnessed according to Baumüller standard (PVC-/PUR-Servo cable)

Minimum

Page

bending

334

radius [x d]

to 337

28 A-Extension cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø

Minimum

Page

bending

334

radius [x d]

to 337

18,5

10

4

[mm]

36 A-Basic cable

PVC

MAT9750249

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

326600 (5 m)

PVC

MAT9750250

(4 G 6,0+2x(2x1,5)C)C

PVC

MAT9297060

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

326600 (5 m)

PVC

MAT9295070

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

PUR

MAT9850249

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

326600 (5 m)

PUR

MAT9850250

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

PUR

MAT9298060

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

326600 (5 m)

PUR

MAT9296070

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

326601 (7 m)

PVC

MAT9750251

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

326601 (7 m)

PVC

MAT9295071

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

326601 (7 m)

PUR

MAT9850251

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

326601 (7 m)

PUR

MAT9296071

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

326602 (10 m)

PVC

MAT9750252

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

326602 (10 m)

PVC

MAT9295072

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

326602 (10 m)

PUR

MAT9850252

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

326602 (10 m)

PUR

MAT9296072

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

326603 (15 m)

PVC

MAT9750253

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

326603 (15 m)

PVC

MAT9295073

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

326603 (15 m)

PUR

MAT9850253

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

326603 (15 m)

PUR

MAT9296073

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

326604 (20 m)

PVC

MAT9750254

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

326604 (20 m)

PVC

MAT9295074

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

326604 (20 m)

PUR

MAT9850254

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

326604 (20 m)

PUR

MAT9296074

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

326605 (25 m)

PVC

MAT9750255

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

326605 (25 m)

PVC

MAT9295075

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

326605 (25 m)

PUR

MAT9850255

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

326605 (25 m)

PUR

MAT9296075

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

326606 (30 m)

PVC

MAT9750256

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

326606 (30 m)

PVC

MAT9295076

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

326606 (30 m)

PUR

MAT9850256

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

326606 (30 m)

PUR

MAT9296076

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

326607 (35 m)

PVC

MAT9750257

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

326607 (35 m)

PVC

MAT9295077

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

326607 (35 m)

PUR

MAT9850257

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

326607 (35 m)

PUR

MAT9296077

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

326608 (40 m)

PVC

MAT9750258

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

326608 (40 m)

PVC

MAT9295078

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

326608 (40 m)

PUR

MAT9850258

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

326608 (40 m)

PUR

MAT9296078

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 366

26

Baumüller readycable® PVC/PUR

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

367


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:11 Seite 368

Baumüller readycable® PVC/PUR

Baumüller harnessed drive cables ... optionally with PVC-/PUR-jacket

Baumüller harnessed drive cables ... optionally with PVC-/PUR-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Baumüller standard (PVC-/PUR-Servo cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

26

Baumüller readycable® PVC/PUR

Page 334-337

Harnessed according to Baumüller standard (PVC-/PUR-Servo cable)

Minimum

Page

bending

334

radius [x d]

to 337

36 A-Extension cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

7,5

5

50 A-Basic cable

PVC

MAT9750259

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

326609 (5 m)

PVC

MAT9295080

(4 G 10,0+2x(2x1,5)C)C

24,0

PVC

MAT9297070

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

326609 (5 m)

PUR

MAT9850260

(4 G 10,0+2x(2x1,5)C)C

22,0

10

6

PUR

MAT9850259

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

326609 (5 m)

PUR

MAT9296080

(4 G 10,0+2x(2x1,5)C)C

23,5

7,5

7

PUR

MAT9298070

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

326610 (7 m)

PVC

MAT9295081

(4 G 10,0+2x(2x1,5)C)C

24,0

7,5

5

326610 (7 m)

PUR

MAT9850261

(4 G 10,0+2x(2x1,5)C)C

22,0

10

6

326610 (7 m)

PUR

MAT9296081

(4 G 10,0+2x(2x1,5)C)C

23,5

7,5

7

326611 (10 m)

PVC

MAT9295082

(4 G 10,0+2x(2x1,5)C)C

24,0

7,5

5

326611 (10 m)

PUR

MAT9850262

(4 G 10,0+2x(2x1,5)C)C

22,0

10

6

326611 (10 m)

PUR

MAT9296082

(4 G 10,0+2x(2x1,5)C)C

23,5

7,5

7

326612 (15 m)

PVC

MAT9295083

(4 G 10,0+2x(2x1,5)C)C

24,0

7,5

5

326612 (15 m)

PUR

MAT9850263

(4 G 10,0+2x(2x1,5)C)C

22,0

10

6

326612 (15 m)

PUR

MAT9296083

(4 G 10,0+2x(2x1,5)C)C

23,5

7,5

7

326613 (20 m)

PVC

MAT9295084

(4 G 10,0+2x(2x1,5)C)C

24,0

7,5

5

326613 (20 m)

PUR

MAT9850264

(4 G 10,0+2x(2x1,5)C)C

22,0

10

6

326613 (20 m)

PUR

MAT9296084

(4 G 10,0+2x(2x1,5)C)C

23,5

7,5

7

326614 (25 m)

PVC

MAT9295085

(4 G 10,0+2x(2x1,5)C)C

24,0

7,5

5

326614 (25 m)

PUR

MAT9850265

(4 G 10,0+2x(2x1,5)C)C

22,0

10

6

326614 (25 m)

PUR

MAT9296085

(4 G 10,0+2x(2x1,5)C)C

23,5

7,5

7

326615 (30 m)

PVC

MAT9295086

(4 G 10,0+2x(2x1,5)C)C

24,0

7,5

5

326615 (30 m)

PUR

MAT9850266

(4 G 10,0+2x(2x1,5)C)C

22,0

10

6

326615 (30 m)

PUR

MAT9296086

(4 G 10,0+2x(2x1,5)C)C

23,5

7,5

7

326616 (35 m)

PVC

MAT9295087

(4 G 10,0+2x(2x1,5)C)C

24,0

7,5

5

326616 (35 m)

PUR

MAT9850267

(4 G 10,0+2x(2x1,5)C)C

22,0

10

6

326616 (35 m)

PUR

MAT9296087

(4 G 10,0+2x(2x1,5)C)C

23,5

7,5

7

326617 (40 m)

PVC

MAT9295088

(4 G 10,0+2x(2x1,5)C)C

24,0

7,5

5

326617 (40 m)

PUR

MAT9850268

(4 G 10,0+2x(2x1,5)C)C

22,0

10

6

326617 (40 m)

PUR

MAT9296088

(4 G 10,0+2x(2x1,5)C)C

23,5

7,5

7

PVC

MAT9297080

(4 G 10,0+2x(2x1,5)C)C

24,0

7,5

5

PUR

MAT9850269

(4 G 10,0+2x(2x1,5)C)C

22,0

10

6

PUR

MAT9298080

(4 G 10,0+2x(2x1,5)C)C

23,5

7,5

7

50 A-Extension cable

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 368

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

369


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:11 Seite 370

Baumüller readycable® PVC/PUR/TPE

Baumüller harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

Baumüller harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Baumüller standard (PVC-/PUR-/TPE-Resolver cable) Manufacturer Part No.

igus®

Jacket material

Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

PVC

246658 (3 m) 246658 (3 m)

bending

334

radius [x d]

to 337

Manufacturer Part No.

igus®

Jacket material

Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

8

SRS/SRM50 & SKS/SKM36 Basic cable

MAT9290001

(5x(2x0,14)+2x0,5)C

9,0

10

8

239546 (30 m)

PVC

MAT9290010

(5x(2x0,14)+2x0,5)C

9,0

10

PUR

MAT9840201

(5x(2x0,14)+2x0,5)C

9,0

TPE

MAT9940201

(5x(2x0,14)+2x0,5)C

9,0

10

9

239546 (30 m)

PUR

MAT9840210

(5x(2x0,14)+2x0,5)C

9,0

10

9

12

10

239546 (30 m)

TPE

MAT9940210

(5x(2x0,14)+2x0,5)C

9,0

12

10

246658 (3 m)

TPE

MAT9291001

(5x(2x0,14)+2x0,5)C

243379 (4 m)

PVC

MAT9290002

(5x(2x0,14)+2x0,5)C

9,0

10

11

239546 (30 m)

TPE

MAT9291010

(5x(2x0,14)+2x0,5)C

9,0

10

11

9,0

10

8

239547 (35 m)

PVC

MAT9290011

(5x(2x0,14)+2x0,5)C

9,0

10

8

243379 (4 m)

PUR

MAT9840202

243379 (4 m)

TPE

MAT9940202

(5x(2x0,14)+2x0,5)C

9,0

10

9

239547 (35 m)

PUR

MAT9840211

(5x(2x0,14)+2x0,5)C

9,0

10

9

(5x(2x0,14)+2x0,5)C

9,0

12

10

239547 (35 m)

TPE

MAT9940211

(5x(2x0,14)+2x0,5)C

9,0

12

10

243379 (4 m)

TPE

239540 (5 m)

PVC

MAT9291002

(5x(2x0,14)+2x0,5)C

9,0

10

11

239547 (35 m)

TPE

MAT9291011

(5x(2x0,14)+2x0,5)C

9,0

10

11

MAT9290003

(5x(2x0,14)+2x0,5)C

9,0

10

8

240520 (40 m)

PVC

MAT9290012

(5x(2x0,14)+2x0,5)C

9,0

10

8

239540 (5 m) 239540 (5 m)

PUR

MAT9840203

(5x(2x0,14)+2x0,5)C

9,0

10

9

240520 (40 m)

PUR

MAT9840212

(5x(2x0,14)+2x0,5)C

9,0

10

9

TPE

MAT9940203

(5x(2x0,14)+2x0,5)C

9,0

12

10

240520 (40 m)

TPE

MAT9940212

(5x(2x0,14)+2x0,5)C

9,0

12

10

239540 (5 m)

TPE

MAT9291003

(5x(2x0,14)+2x0,5)C

9,0

10

11

240520 (40 m)

TPE

MAT9291012

(5x(2x0,14)+2x0,5)C

9,0

10

11

242954 (6 m)

PVC

MAT9290004

(5x(2x0,14)+2x0,5)C

9,0

10

8

240521 (45 m)

PVC

MAT9290013

(5x(2x0,14)+2x0,5)C

9,0

10

8

242954 (6 m)

PUR

MAT9840204

(5x(2x0,14)+2x0,5)C

9,0

10

9

240521 (45 m)

PUR

MAT9840213

(5x(2x0,14)+2x0,5)C

9,0

10

9

242954 (6 m)

TPE

MAT9940204

(5x(2x0,14)+2x0,5)C

9,0

12

10

240521 (45 m)

TPE

MAT9940213

(5x(2x0,14)+2x0,5)C

9,0

12

10

242954 (6 m)

TPE

MAT9291004

(5x(2x0,14)+2x0,5)C

9,0

10

11

240521 (45 m)

TPE

MAT9291013

(5x(2x0,14)+2x0,5)C

9,0

10

11

239541 (8 m)

PVC

MAT9290005

(5x(2x0,14)+2x0,5)C

9,0

10

8

240522 (50 m)

PVC

MAT9290014

(5x(2x0,14)+2x0,5)C

9,0

10

8

239541 (8 m)

PUR

MAT9840205

(5x(2x0,14)+2x0,5)C

9,0

10

9

240522 (50 m)

PUR

MAT9840214

(5x(2x0,14)+2x0,5)C

9,0

10

9

239541 (8 m)

TPE

MAT9940205

(5x(2x0,14)+2x0,5)C

9,0

12

10

240522 (50 m)

TPE

MAT9940214

(5x(2x0,14)+2x0,5)C

9,0

12

10

239541 (8 m)

TPE

MAT9291005

(5x(2x0,14)+2x0,5)C

9,0

10

11

240522 (50 m)

TPE

MAT9291014

(5x(2x0,14)+2x0,5)C

9,0

10

11

239542 (10 m)

PVC

MAT9290006

(5x(2x0,14)+2x0,5)C

9,0

10

8

244033 (55 m)

PVC

MAT9290015

(5x(2x0,14)+2x0,5)C

9,0

10

8

239542 (10 m)

PUR

MAT9840206

(5x(2x0,14)+2x0,5)C

9,0

10

9

244033 (55m)

PUR

MAT9840215

(5x(2x0,14)+2x0,5)C

9,0

10

9

239542 (10 m)

TPE

MAT9940206

(5x(2x0,14)+2x0,5)C

9,0

12

10

244033 (55m)

TPE

MAT9940215

(5x(2x0,14)+2x0,5)C

9,0

12

10

239542 (10 m)

TPE

MAT9291006

(5x(2x0,14)+2x0,5)C

9,0

10

11

244033 (55 m)

TPE

MAT9291015

(5x(2x0,14)+2x0,5)C

9,0

10

11

239543 (15 m)

PVC

MAT9290007

(5x(2x0,14)+2x0,5)C

9,0

10

8

245484 (60 m)

PVC

MAT9290016

(5x(2x0,14)+2x0,5)C

9,0

10

8

239543 (15 m)

PUR

MAT9840207

(5x(2x0,14)+2x0,5)C

9,0

10

9

245484 (60 m)

PUR

MAT9840216

(5x(2x0,14)+2x0,5)C

9,0

10

9

239543 (15 m)

TPE

MAT9940207

(5x(2x0,14)+2x0,5)C

9,0

12

10

245484 (60 m)

TPE

MAT9940216

(5x(2x0,14)+2x0,5)C

9,0

12

10

245484 (60 m)

TPE

MAT9291016

(5x(2x0,14)+2x0,5)C

9,0

10

11

239543 (15 m)

TPE

MAT9291007

(5x(2x0,14)+2x0,5)C

9,0

10

11

239544 (20m)

PVC

MAT9290008

(5x(2x0,14)+2x0,5)C

9,0

10

8

239544 (20 m)

PUR

MAT9840208

(5x(2x0,14)+2x0,5)C

9,0

10

9

239544 (20 m)

TPE

MAT9940208

(5x(2x0,14)+2x0,5)C

9,0

12

10

SRS/SRM50 & SKS/SKM36 Extension cable

239544 (20m)

TPE

MAT9291008

(5x(2x0,14)+2x0,5)C

9,0

10

11

PVC

MAT9292001

(5x(2x0,14)+2x0,5)C

9,0

10

8

239545 (25 m)

PVC

MAT9290009

(5x(2x0,14)+2x0,5)C

9,0

10

8

PUR

MAT9840217

(5x(2x0,14)+2x0,5)C

9,0

10

9

239545 (25 m)

PUR

MAT9840209

(5x(2x0,14)+2x0,5)C

9,0

10

9

TPE

MAT9940217

(5x(2x0,14)+2x0,5)C

9,0

12

10

239545 (25 m)

TPE

MAT9940209

(5x(2x0,14)+2x0,5)C

9,0

12

10

TPE

MAT9293001

(5x(2x0,14)+2x0,5)C

9,0

10

11

239545 (25 m)

TPE

MAT9291009

(5x(2x0,14)+2x0,5)C

9,0

10

11

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 370

Page 334-337

26

Harnessed according to Baumüller standard (PVC-/PUR-/TPE-Resolver cable) Page

SRS/SRM50 & SKS/SKM36 Basic cable 246658 (3 m)

Baumüller readycable® PVC/PUR/TPE

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

371


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:11 Seite 372

Baumüller readycable® PVC/PUR/TPE

Baumüller harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

Baumüller harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Baumüller standard (PVC-/PUR-/TPE-Pulse encoder cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page 334-337

Harnessed according to Baumüller standard (PVC-/PUR-/TPE-Pulse encoder cable) Page

bending

334

radius [x d]

to 337

Pulse encoder Basic cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

8

Pulse encoder Basic cable

198962 (3 m)

PVC

MAT9290020

(5x(2x0,14)+2x0,5)C

9,0

10

8

208829 (40 m)

PVC

MAT9290029

(5x(2x0,14)+2x0,5)C

9,0

10

198962 (3 m) 198962 (3 m)

PUR

MAT9840218

(5x(2x0,14)+2x0,5)C

9,0

TPE

MAT9940218

(5x(2x0,14)+2x0,5)C

9,0

10

9

208829 (40 m)

PUR

MAT9840227

(5x(2x0,14)+2x0,5)C

9,0

10

9

12

10

208829 (40 m)

TPE

MAT9940227

(5x(2x0,14)+2x0,5)C

9,0

12

10

198962 (3 m)

TPE

MAT9291020

(5x(2x0,14)+2x0,5)C

198963 (5 m)

PVC

MAT9290021

(5x(2x0,14)+2x0,5)C

9,0

10

11

208829 (40 m)

TPE

MAT9291029

(5x(2x0,14)+2x0,5)C

9,0

10

11

9,0

10

8

198963 (5 m)

PUR

MAT9840219

198963 (5 m)

TPE

MAT9940219

(5x(2x0,14)+2x0,5)C

9,0

10

9

(5x(2x0,14)+2x0,5)C

9,0

12

10

198963 (5 m)

TPE

198964 (8 m)

PVC

MAT9291021

(5x(2x0,14)+2x0,5)C

9,0

10

11

PVC

MAT9292020

(5x(2x0,14)+2x0,5)C

9,0

10

8

MAT9290022

(5x(2x0,14)+2x0,5)C

9,0

10

8

PUR

MAT9840228

(5x(2x0,14)+2x0,5)C

9,0

10

9

198964 (8 m) 198964 (8 m)

PUR

MAT9840220

(5x(2x0,14)+2x0,5)C

9,0

10

9

TPE

MAT9940228

(5x(2x0,14)+2x0,5)C

9,0

12

10

TPE

MAT9940220

(5x(2x0,14)+2x0,5)C

9,0

12

10

TPE

MAT9293020

(5x(2x0,14)+2x0,5)C

9,0

10

11

198964 (8 m)

TPE

MAT9291022

(5x(2x0,14)+2x0,5)C

9,0

10

11

198965 (10 m)

PVC

MAT9290023

(5x(2x0,14)+2x0,5)C

9,0

10

8

198965 (10 m)

PUR

MAT9840221

(5x(2x0,14)+2x0,5)C

9,0

10

9

198965 (10 m)

TPE

MAT9940221

(5x(2x0,14)+2x0,5)C

9,0

12

10

198965 (10 m)

TPE

MAT9291023

(5x(2x0,14)+2x0,5)C

9,0

10

11

198966 (15 m)

PVC

MAT9290024

(5x(2x0,14)+2x0,5)C

9,0

10

8

198966 (15 m)

PUR

MAT9840222

(5x(2x0,14)+2x0,5)C

9,0

10

9

198966 (15 m)

TPE

MAT9940222

(5x(2x0,14)+2x0,5)C

9,0

12

10

198966 (15 m)

TPE

MAT9291024

(5x(2x0,14)+2x0,5)C

9,0

10

11

198967 (20 m)

PVC

MAT9290025

(5x(2x0,14)+2x0,5)C

9,0

10

8

198967 (20 m)

PUR

MAT9840223

(5x(2x0,14)+2x0,5)C

9,0

10

9

198967 (20 m)

TPE

MAT9940223

(5x(2x0,14)+2x0,5)C

9,0

12

10

198967 (20 m)

TPE

MAT9291025

(5x(2x0,14)+2x0,5)C

9,0

10

11

198968 (25 m)

PVC

MAT9290026

(5x(2x0,14)+2x0,5)C

9,0

10

8

198968 (25 m)

PUR

MAT9840224

(5x(2x0,14)+2x0,5)C

9,0

10

9

198968 (25 m)

TPE

MAT9940224

(5x(2x0,14)+2x0,5)C

9,0

12

10

198968 (25 m)

TPE

MAT9291026

(5x(2x0,14)+2x0,5)C

9,0

10

11

198969 (30 m)

PVC

MAT9290027

(5x(2x0,14)+2x0,5)C

9,0

10

8

198969 (30 m)

PUR

MAT9840225

(5x(2x0,14)+2x0,5)C

9,0

10

9

198969 (30 m)

TPE

MAT9940225

(5x(2x0,14)+2x0,5)C

9,0

12

10

198969 (30 m)

TPE

MAT9291027

(5x(2x0,14)+2x0,5)C

9,0

10

11

225360 (35 m)

PVC

MAT9290028

(5x(2x0,14)+2x0,5)C

9,0

10

8

225360 (35 m)

PUR

MAT9840226

(5x(2x0,14)+2x0,5)C

9,0

10

9

225360 (35 m)

TPE

MAT9940226

(5x(2x0,14)+2x0,5)C

9,0

12

10

225360 (35 m)

TPE

MAT9291028

(5x(2x0,14)+2x0,5)C

9,0

10

11

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 372

26

Baumüller readycable® PVC/PUR/TPE

(for up to 10 cuts of the same type)

Pulse encoder Extension cable

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

373


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:11 Seite 374

Baumüller readycable® PVC/PUR/TPE

Baumüller harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

Baumüller harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Baumüller standard (PVC-/PUR-/TPE-Encoder cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page 334-337

Harnessed according to Baumüller standard (PVC-/PUR-/TPE-Encoder cable) Page

bending

334

radius [x d]

to 337

ECN1313/EQN1325 Basic cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

8

ECN1313/EQN1325 Basic cable

393889 (2 m)

PVC

MAT9290030

(5x(2x0,14)+2x0,5)C

9,0

10

8

393893 (25 m)

PVC

MAT9290039

(5x(2x0,14)+2x0,5)C

9,0

10

393889 (2m) 393889 (2m)

PUR

MAT9840229

(5x(2x0,14)+2x0,5)C

9,0

TPE

MAT9940229

(5x(2x0,14)+2x0,5)C

9,0

10

9

393893 (25 m)

PUR

MAT9840238

(5x(2x0,14)+2x0,5)C

9,0

10

9

12

10

393893 (25 m)

TPE

MAT9940238

(5x(2x0,14)+2x0,5)C

9,0

12

10

393889 (2 m)

TPE

MAT9291030

(5x(2x0,14)+2x0,5)C

369864 (3 m)

PVC

MAT9290031

(5x(2x0,14)+2x0,5)C

9,0

10

11

393893 (25 m)

TPE

MAT9291039

(5x(2x0,14)+2x0,5)C

9,0

10

11

9,0

10

8

393894 (30 m)

PVC

MAT9290040

(5x(2x0,14)+2x0,5)C

9,0

10

8

369864 (3 m)

PUR

MAT9840230

369864 (3 m)

TPE

MAT9940230

(5x(2x0,14)+2x0,5)C

9,0

10

9

393894 (30 m)

PUR

MAT9840239

(5x(2x0,14)+2x0,5)C

9,0

10

9

(5x(2x0,14)+2x0,5)C

9,0

12

10

393894 (30 m)

TPE

MAT9940239

(5x(2x0,14)+2x0,5)C

9,0

12

10

369864 (3 m)

TPE

394014 (5 m)

PVC

MAT9291031

(5x(2x0,14)+2x0,5)C

9,0

10

11

393894 (30 m)

TPE

MAT9291040

(5x(2x0,14)+2x0,5)C

9,0

10

11

MAT9290032

(5x(2x0,14)+2x0,5)C

9,0

10

8

380358 (35 m)

PVC

MAT9290041

(5x(2x0,14)+2x0,5)C

9,0

10

8

394014 (5 m) 394014 (5 m)

PUR

MAT9840231

(5x(2x0,14)+2x0,5)C

9,0

10

9

380358 (35 m)

PUR

MAT9840240

(5x(2x0,14)+2x0,5)C

9,0

10

9

TPE

MAT9940231

(5x(2x0,14)+2x0,5)C

9,0

12

10

380358 (35 m)

TPE

MAT9940240

(5x(2x0,14)+2x0,5)C

9,0

12

10

394014 (5 m)

TPE

MAT9291032

(5x(2x0,14)+2x0,5)C

9,0

10

11

380358 (35 m)

TPE

MAT9291041

(5x(2x0,14)+2x0,5)C

9,0

10

11

389807 (7 m)

PVC

MAT9290033

(5x(2x0,14)+2x0,5)C

9,0

10

8

391216 (40 m)

PVC

MAT9290042

(5x(2x0,14)+2x0,5)C

9,0

10

8

389807 (7 m)

PUR

MAT9840232

(5x(2x0,14)+2x0,5)C

9,0

10

9

391216 (40 m)

PUR

MAT9840241

(5x(2x0,14)+2x0,5)C

9,0

10

9

389807 (7 m)

TPE

MAT9940232

(5x(2x0,14)+2x0,5)C

9,0

12

10

391216 (40 m)

TPE

MAT9940241

(5x(2x0,14)+2x0,5)C

9,0

12

10

389807 (7 m)

TPE

MAT9291033

(5x(2x0,14)+2x0,5)C

9,0

1

11

391216 (40 m)

TPE

MAT9291042

(5x(2x0,14)+2x0,5)C

9,0

10

11

393890 (8 m)

PVC

MAT9290034

(5x(2x0,14)+2x0,5)C

9,0

10

8

382005 (45 m)

PVC

MAT9290043

(5x(2x0,14)+2x0,5)C

9,0

10

8

393890 (8 m)

PUR

MAT9840233

(5x(2x0,14)+2x0,5)C

9,0

10

9

382005 (45 m)

PUR

MAT9840242

(5x(2x0,14)+2x0,5)C

9,0

10

9

393890 (8 m)

TPE

MAT9940233

(5x(2x0,14)+2x0,5)C

9,0

12

10

382005 (45 m)

TPE

MAT9940242

(5x(2x0,14)+2x0,5)C

9,0

12

10

393890 (8 m)

TPE

MAT9291034

(5x(2x0,14)+2x0,5)C

9,0

10

11

382005 (45 m)

TPE

MAT9291043

(5x(2x0,14)+2x0,5)C

9,0

10

11

389808 (9 m)

PVC

MAT9290035

(5x(2x0,14)+2x0,5)C

9,0

10

8

378022 (50 m)

PVC

MAT9290044

(5x(2x0,14)+2x0,5)C

9,0

10

8

389808 (9m)

PUR

MAT9840234

(5x(2x0,14)+2x0,5)C

9,0

10

9

378022 (50 m)

PUR

MAT9840243

(5x(2x0,14)+2x0,5)C

9,0

10

9

389808 (9m)

TPE

MAT9940234

(5x(2x0,14)+2x0,5)C

9,0

12

10

378022 (50 m)

TPE

MAT9940243

(5x(2x0,14)+2x0,5)C

9,0

12

10

389808 (9 m)

TPE

MAT9291035

(5x(2x0,14)+2x0,5)C

9,0

10

11

378022 (50 m)

TPE

MAT9291044

(5x(2x0,14)+2x0,5)C

9,0

10

11

393891 (10 m)

PVC

MAT9290036

(5x(2x0,14)+2x0,5)C

9,0

10

8

393891 (10 m)

PUR

MAT9840235

(5x(2x0,14)+2x0,5)C

9,0

10

9

393891 (10 m)

TPE

MAT9940235

(5x(2x0,14)+2x0,5)C

9,0

12

10

ECN1313/EQN1325 Extension cable

393891 (10 m)

TPE

MAT9291036

(5x(2x0,14)+2x0,5)C

9,0

10

11

PVC

MAT9292030

(5x(2x0,14)+2x0,5)C

9,0

10

8

393892 (15 m)

PVC

MAT9290037

(5x(2x0,14)+2x0,5)C

9,0

10

8

PUR

MAT9840244

(5x(2x0,14)+2x0,5)C

9,0

10

9

393892 (15 m)

PUR

MAT9840236

(5x(2x0,14)+2x0,5)C

9,0

10

9

TPE

MAT9940244

(5x(2x0,14)+2x0,5)C

9,0

12

10

393892 (15 m)

TPE

MAT9940236

(5x(2x0,14)+2x0,5)C

9,0

12

10

TPE

MAT9293030

(5x(2x0,14)+2x0,5)C

9,0

10

11

393892 (15 m)

TPE

MAT9291037

(5x(2x0,14)+2x0,5)C

9,0

10

11

371494 (20 m)

PVC

MAT9290038

(5x(2x0,14)+2x0,5)C

9,0

10

8

371494 (20 m)

PUR

MAT9840237

(5x(2x0,14)+2x0,5)C

9,0

10

9

371494 (20 m)

TPE

MAT9940237

(5x(2x0,14)+2x0,5)C

9,0

12

10

371494 (20 m)

TPE

MAT9291038

(5x(2x0,14)+2x0,5)C

9,0

10

11

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 374

26

Baumüller readycable® PVC/PUR/TPE

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

375


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:12 Seite 376

Beckhoff readycable® PVC/PUR

Beckhoff harnessed drive cables ... optionally with PVC-/PUR-jacket

Beckhoff harnessed drive cables ... optionally with PVC-/PUR-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Beckhoff standard (PVC-/PUR-Servo cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

26

Beckhoff readycable® PVC/PUR

Page 334-337

Harnessed according to Beckhoff standard (PVC-/PUR-Servo cable)

Minimum

Page

bending

334

radius [x d]

to 337

Basic cable

Jacket

Manufacturer

material

Part No.

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø

Minimum

Page

bending

334

radius [x d]

to 337

15,5

10

4

[mm]

Extension cable

ZK4000-2111-xxxx

PVC

MAT9750305

(4 G 1,5+(2x1,5)C)C

12,0

10

4

ZK4501-0024-xxxx

PVC

ZK4000-2111-xxxx

PVC

MAT9371005

ZK4000-2111-xxxx

PUR

MAT9850305

ZK4000-2111-xxxx

PUR

MAT9372005

ZK4000-2711-xxxx

PVC

MAT9750307

ZK4000-2711-xxxx

PVC

MAT9371007

ZK4000-2711-xxxx

PUR

MAT9850307

ZK4000-2711-xxxx

PUR

MAT9372007

(4 G 1,5+(2x1,5)C)C

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

ZK4501-0024-xxxx

PVC

MAT9371004

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

(4 G 1,5+(2x1,5)C)C

12,0

10

6

ZK4501-0024-xxxx

PUR

MAT9850304

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

ZK4501-0024-xxxx

PUR

MAT9372004

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

(4 G 1,5+(2x1,5)C)C

12,0

10

4

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

(4 G 1,5+(2x1,5)C)C

12,0

10

6

13,0

7,5

7

Basic cable

MAT9750304

(4 G 2,5+2x(2x1,5)C)C

Harnessed according to Beckhoff standard (PVC-/PUR-Encoder cable)

Basic cable ZK4000-2610-xxxx

PVC

MAT9381004

(8x(2x0,25))C

11,5

10

14

ZK4000-2610-xxxx

PUR

MAT9382004

(8x(2x0,25))C

11,5

10

15

Basic cable

ZK4000-2112-xxxx

PVC

MAT9750306

(4 G 2,5+(2x1,5)C)C

13,5

10

4

ZK4000-2112-xxxx

PVC

MAT9371006

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

ZK4000-2112-xxxx

PUR

MAT9850306

(4 G 2,5+(2x1,5)C)C

13,5

10

6

ZK4510-0020-xxxx

PVC

MAT9381001

(8x(2x0,25))C

11,5

10

14

ZK4000-2112-xxxx

PUR

MAT9372006

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

ZK4510-0020-xxxx

PUR

MAT9382001

(8x(2x0,25))C

11,5

10

15

Basic cable

Basic cable

ZK4500-0023-xxxx

PVC

MAT9750301

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

ZK4520-0020-xxxx

PVC

MAT9381002

(6x(2x0,25))C

9,5

10

14

ZK4500-0023-xxxx

PVC

MAT9371001

ZK4500-0023-xxxx

PUR

MAT9850301

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

ZK4520-0020-xxxx

PUR

MAT9382002

(6x(2x0,25))C

10,0

10

15

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

ZK4500-0023-xxxx

PUR

MAT9372001

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

ZK4511-0020-xxxx

PVC

MAT9381003

(8x(2x0,25))C

11,5

10

14

ZK4511-0020-xxxx

PUR

MAT9382003

(8x(2x0,25))C

11,5

10

15

Basic cable ZK4500-0024-xxxx

PVC

MAT9750302

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

ZK4500-0024-xxxx

PVC

MAT9371002

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

ZK4500-0024-xxxx

PUR

MAT9850302

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

ZK4500-0024-xxxx

PUR

MAT9372002

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

ZK4501-0023-xxxx

PVC

MAT9750303

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

ZK4501-0023-xxxx

PVC

MAT9371003

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

ZK4501-0023-xxxx

PUR

MAT9850303

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

ZK4501-0023-xxxx

PUR

MAT9372003

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

Extension cable

Extension cable

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 376

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

377


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:12 Seite 378

Beckhoff readycable® PVC/PUR/TPE

Beckhoff harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

Berger Lahr harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Beckhoff standard (PVC-/PUR-/TPE-Resolver cable) Manufacturer

Jacket material

Part No.

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

26

Berger Lahr readycable® PVC/PUR/TPE

Page 334-337

Harnessed according to Berger Lahr standard (PVC-/PUR-Servo cable) Page

bending

334

radius [x d]

to 337

Basic cable

Manufacturer

Jacket material

Part No.

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø

Minimum

Page

bending

334

radius [x d]

to 337

12,0

10

4

[mm]

Basic cable

ZK4000-2210-xxxx

PVC

MAT9383003

(4x(2x0,25))C

ZK4000-2210-xxxx

PUR

MAT9384003

(4x(2x0,25))C

ZK4000-2210-xxxx

TPE

MAT9920303

(4 x (2 x 0,25))C

8,0

10

14

VW3M5101Rxxx

PVC

9,0

10

15

VW3M5101Rxxx

PVC

MAT94502001 (4 G 1,5+(2x1,5)C)C

13,0

7,5

5

9,0

6,8

16

VW3M5101Rxxx

PUR

MAT94501001 (4 G 1,5+(2x1,5)C)C

12,0

10

6

VW3M5101Rxxx

PUR

MAT94500001 (4 G 1,5+(2x1,5)C)C

13,0

7,5

7

VW3M5102Rxxx

PVC

MAT94503002 (4 G 2,5+(2x1,5)C)C

13,5

10

4

Basic cable ZK4530-0010-xxxx

PVC

MAT9383001

(4x(2x0,25))C

ZK4530-0010-xxxx

PUR

MAT9384001

(4x(2x0,25))C

ZK4530-0010-xxxx

TPE

MAT9920301

(4 x (2 x 0,25))C

MAT94503001 (4 G 1,5+(2x1,5)C)C

VW3M5102Rxxx

PVC

MAT94502003 (4 G 2,5+(2x1,5)C)C

14,0

7,5

5

10

14

VW3M5102Rxxx

PUR

MAT94501003 (4 G 2,5+(2x1,5)C)C

13,5

10

6

9,0

10

15

VW3M5102Rxxx

PUR

MAT94500003 (4 G 2,5+(2x1,5)C)C

14,5

7,5

7

9,0

6,8

16

8,0

Extension cable

Harnessed according to Berger Lahr standard (PVC-/PUR-/TPE-Resolver cable)

Basic cable

ZK4531-0020-xxxx

PVC

MAT9383002

(4x(2x0,25))C

ZK4531-0020-xxxx

PUR

MAT9384002

(4x(2x0,25))C

ZK4531-0020-xxxx

TPE

MAT9920302

(4 x (2 x 0,25))C

8,0

10

14

VW3M8101Rxxx

PVC

MAT94603001 (4x(2x0,34)+4x0,5)C

9,0

10

9,0

10

15

VW3M8101Rxxx

PUR

MAT94601001 (4x(2x0,34)+4x0,5)C

10,5

10

9

9,0

6,8

16

VW3M8101Rxxx

TPE

MAT94600001 (4x(2x0,34)+4x0,5)C

10,5

10

11

8

Harnessed according to Beckhoff standard (TPE-Network cable EtherCAT)

Basic cable ZK1090-9191-xxxx

TPE

MAT9385001

(2x(2x0,25))C

7,0

12,5

12

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 378

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

379


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:12 Seite 380

Control T. readycable® PVC/TPE

Control Techniques harnessed drive cables ... optionally with PVC-/TPE-jacket

Control Techniques harnessed drive cables ... optionally with PVC-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Control Techniques standard (PVC-/TPE-Power cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page 334-337

Harnessed according to Control Techniques standard (PVC-/TPE-Power cable) Page

bending

334

radius [x d]

to 337

Basic cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

PS B B F B XXX

PVC

MAT9560015

(4 G 4,0)C

13,5

7,5

1

PS B B F B XXX

TPE

MAT9540015

(4 G 4,0)C

13,5

7,5

2

PS B B F B XXX

TPE

MAT9960515

(4 G 4,0)C

13,5

7,5

3

PS B A A A XXX

PVC

MAT9560002

(4 G 2,5)C

12,0

7,5

1

PS B C A B XXX

PVC

MAT9560010

(4 G 6,0)C

16,0

7,5

1

PS B A A A XXX

TPE

MAT9540002

(4 G 2,5)C

11,5

7,5

2

PS B C A B XXX

TPE

MAT9540010

(4 G 6,0)C

16,0

7,5

2

PS B A A A XXX

TPE

MAT9960502

(4 G 2,5)C

11,5

7,5

3

PS B C A B XXX

TPE

MAT9960510

(4 G 6,0)C

16,0

7,5

3

PS B A F A XXX

PVC

MAT9560005

(4 G 2,5)C

12,0

7,5

1

PS B C B B XXX

PVC

MAT9560022

(4 G 6,0)C

16,0

7,5

1

PS B A F A XXX

TPE

MAT9540005

(4 G 2,5)C

11,5

7,5

2

PS B C B B XXX

TPE

MAT9540022

(4 G 6,0)C

16,0

7,5

2

PS B A F A XXX

TPE

MAT9960505

(4 G 2,5)C

11,5

7,5

3

PS B C B B XXX

TPE

MAT9960522

(4 G 6,0)C

16,0

7,5

3

PS B B A A XXX

PVC

MAT9560003

(4 G 4,0)C

13,5

7,5

1

PS B C F B XXX

PVC

MAT9560016

(4 G 6,0)C

16,0

7,5

1

PS B B A A XXX

TPE

MAT9540003

(4 G 4,0)C

13,5

7,5

2

PS B C F B XXX

TPE

MAT9540016

(4 G 6,0)C

16,0

7,5

2

PS B B A A XXX

TPE

MAT9960503

(4 G 4,0)C

13,5

7,5

3

PS B C F B XXX

TPE

MAT9960516

(4 G 6,0)C

16,0

7,5

3

PS B B F A XXX

PVC

MAT9560006

(4 G 4,0)C

13,5

7,5

1

PS B D A B XXX

PVC

MAT9560011

(4 G 10,0)C

21,0

7,5

1

PS B B F A XXX

TPE

MAT9540006

(4 G 4,0)C

13,5

7,5

2

PS B D A B XXX

TPE

MAT9540011

(4 G 10,0)C

19,5

7,5

2

PS B B F A XXX

TPE

MAT9960506

(4 G 4,0)C

13,5

7,5

3

PS B D A B XXX

TPE

MAT9960511

(4 G 10,0)C

19,5

7,5

3

PS B G A A XXX

PVC

MAT9560001

(4 G 1,5)C

10,5

7,5

1

PS B D B B XXX

PVC

MAT9560023

(4 G 10,0)C

21,0

7,5

1

PS B G A A XXX

TPE

MAT9540001

(4 G 1,5)C

9,5

7,5

2

PS B D B B XXX

TPE

MAT9540023

(4 G 10,0)C

19,5

7,5

2

PS B G A A XXX

TPE

MAT9960501

(4 G 1,5)C

9,5

7,5

3

PS B D B B XXX

TPE

MAT9960523

(4 G 10,0)C

19,5

7,5

3

PS B G F A XXX

PVC

MAT9560004

(4 G 1,5)C

10,5

7,5

1

PS B D F B XXX

PVC

MAT9560017

(4 G 10,0)C

21,0

7,5

1

PS B G F A XXX

TPE

MAT9540004

(4 G 1,5)C

9,5

7,5

2

PS B D F B XXX

TPE

MAT9540017

(4 G 10,0)C

19,5

7,5

2

PS B G F A XXX

TPE

MAT9960504

(4 G 1,5)C

9,5

7,5

3

PS B D F B XXX

TPE

MAT9960517

(4 G 10,0)C

19,5

7,5

3

PS B E A B XXX

PVC

MAT9560012

(4 G 16,0)C

24,0

7,5

1

PS B E A B XXX

TPE

MAT9540012

(4 G 16,0)C

23,0

7,5

2

PS B E A B XXX

TPE

MAT9960512

(4 G 16,0)C

23,0

7,5

3

Basic cable PS B A A B XXX

PVC

MAT9560008

(4 G 2,5)C

12,0

7,5

1

PS B E B B XXX

PVC

MAT9560024

(4 G 16,0)C

24,0

7,5

1

PS B A A B XXX

TPE

MAT9540008

(4 G 2,5)C

11,5

7,5

2

PS B E B B XXX

TPE

MAT9540024

(4 G 16,0)C

23,0

7,5

2

PS B A A B XXX

TPE

MAT9960508

(4 G 2,5)C

11,5

7,5

3

PS B E B B XXX

TPE

MAT9960524

(4 G 16,0)C

23,0

7,5

3

PS B A B B XXX

PVC

MAT9560020

(4 G 2,5)C

12,0

7,5

1

PS B E F B XXX

PVC

MAT9560018

(4 G 16,0)C

24,0

7,5

1

PS B A B B XXX

TPE

MAT9540020

(4 G 2,5)C

11,5

7,5

2

PS B E F B XXX

TPE

MAT9540018

(4 G 16,0)C

23,0

7,5

2

PS B A B B XXX

TPE

MAT9960520

(4 G 2,5)C

11,5

7,5

3

PS B E F B XXX

TPE

MAT9960518

(4 G 16,0)C

23,0

7,5

3

PS B A F B XXX

PVC

MAT9560014

(4 G 2,5)C

12,0

7,5

1

PS B G A B XXX

PVC

MAT9560007

(4 G 1,5)C

10,5

7,5

1

PS B A F B XXX

TPE

MAT9540014

(4 G 2,5)C

11,5

7,5

2

PS B G A B XXX

TPE

MAT9540007

(4 G 1,5)C

9,5

7,5

2

PS B A F B XXX

TPE

MAT9960514

(4 G 2,5)C

11,5

7,5

3

PS B G A B XXX

TPE

MAT9960507

(4 G 1,5)C

9,5

7,5

3

PS B B A B XXX

PVC

MAT9560009

(4 G 4,0)C

13,5

7,5

1

PS B G B B XXX

PVC

MAT9560019

(4 G 1,5)C

10,5

7,5

1

PS B B A B XXX

TPE

MAT9540009

(4 G 4,0)C

13,5

7,5

2

PS B G B B XXX

TPE

MAT9540019

(4 G 1,5)C

9,5

7,5

2

PS B B A B XXX

TPE

MAT9960509

(4 G 4,0)C

13,5

7,5

3

PS B G B B XXX

TPE

MAT9960519

(4 G 1,5)C

9,5

7,5

3

PS B B B B XXX

PVC

MAT9560021

(4 G 4,0)C

13,5

7,5

1

PS B G F B XXX

PVC

MAT9560013

(4 G 1,5)C

10,5

7,5

1

PS B B B B XXX

TPE

MAT9540021

(4 G 4,0)C

13,5

7,5

2

PS B G F B XXX

TPE

MAT9540013

(4 G 1,5)C

9,5

7,5

2

PS B B B B XXX

TPE

MAT9960521

(4 G 4,0)C

13,5

7,5

3

PS B G F B XXX

TPE

MAT9960513

(4 G 1,5)C

9,5

7,5

3

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 380

26

Control T. readycable® PVC/TPE

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

381


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:12 Seite 382

Control T. readycable® PVC/PUR

Control Techniques harnessed drive cables ... optionally with PVC-/PUR-jacket

Control Techniques harnessed drive cables ... optionally with PVC-/PUR-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Control Techniques standard (PVC-/PUR-Servo cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum bending

334

radius [x d]

to 337

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

PB B B B B XXX

PVC

MAT9750517

(4 G 4,0+(2x1,5)C)C

15,0

10

4

PB B B B B XXX

PVC

MAT9560060

(4 G 4,0+(2x1,5)C)C

15,5

7,5

5

PB B B B B XXX

PUR

MAT9540060

(4 G 4,0+(2x1,5)C)C

16,0

7,5

7

10

4

PB B B F B XXX

PVC

MAT9750513

(4 G 4,0+(2x1,5)C)C

15,0

10

4

14,0

7,5

5

PB B B F B XXX

PVC

MAT9560054

(4 G 4,0+(2x1,5)C)C

15,5

7,5

5

14,5

7,5

7

PB B B F B XXX

PUR

MAT9540054

(4 G 4,0+(2x1,5)C)C

16,0

7,5

7

13,5

10

4

PB B B G B XXX

PVC

MAT9750521

(4 G 4,0+(2x1,5)C)C

15,0

10

4

14,0

7,5

5

PB B B G B XXX

PVC

MAT9560066

(4 G 4,0+(2x1,5)C)C

15,5

7,5

5

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

PB B B G B XXX

PUR

MAT9540066

(4 G 4,0+(2x1,5)C)C

16,0

7,5

7

(4 G 4,0+(2x1,5)C)C

15,0

10

4

PB B C A B XXX

PVC

MAT9750510

(4 G 6,0+(2x1,5)C)C

16,5

10

4

15,5

7,5

5

PB B C A B XXX

PVC

MAT9560049

(4 G 6,0+(2x1,5)C)C

18,0

7,5

5

16,0

7,5

7

PB B C A B XXX

PUR

MAT9540049

(4 G 6,0+(2x1,5)C)C

17,5

7,5

7

15,0

10

4

PB B C B B XXX

PVC

MAT9750518

(4 G 6,0+(2x1,5)C)C

16,5

10

4

15,5

7,5

5

PB B C B B XXX

PVC

MAT9560061

(4 G 6,0+(2x1,5)C)C

18,0

7,5

5

(4 G 4,0+(2x1,5)C)C

16,0

7,5

7

PB B C B B XXX

PUR

MAT9540061

(4 G 6,0+(2x1,5)C)C

17,5

7,5

7

(4 G 1,5+(2x1,5)C)C

12,0

10

4

PB B C F B XXX

PVC

MAT9750514

(4 G 6,0+(2x1,5)C)C

16,5

10

4

13,0

7,5

5

PB B C F B XXX

PVC

MAT9560055

(4 G 6,0+(2x1,5)C)C

18,0

7,5

5

13,0

7,5

7

PB B C F B XXX

PUR

MAT9540055

(4 G 6,0+(2x1,5)C)C

17,5

7,5

7

12,0

10

4

PB B C G B XXX

PVC

MAT9750522

(4 G 6,0+(2x1,5)C)C

16,5

10

4

13,0

7,5

5

PB B C G B XXX

PVC

MAT9560067

(4 G 6,0+(2x1,5)C)C

18,0

7,5

5

13,0

7,5

7

PB B C G B XXX

PUR

MAT9540067

(4 G 6,0+(2x1,5)C)C

17,5

7,5

7

PB B D A B XXX

PVC

MAT9560050

(4 G 10,0+(2x1,5)C)C

22,5

7,5

5

PB B D A B XXX

PUR

MAT9540050

(4 G 10,0+(2x1,5)C)C

21,5

7,5

7

PB B D B B XXX

PVC

MAT9560062

(4 G 10,0+(2x1,5)C)C

22,5

7,5

5

PB B A A A XXX

PVC

(4 G 2,5+(2x1,5)C)C

PB B A A A XXX

PVC

MAT9560041

(4 G 2,5+(2x1,5)C)C

PB B A A A XXX

PUR

MAT9540041

(4 G 2,5+(2x1,5)C)C

PB B A F A XXX

PVC

MAT9750505

(4 G 2,5+(2x1,5)C)C

PB B A F A XXX

PVC

MAT9560044

(4 G 2,5+(2x1,5)C)C

PB B A F A XXX

PUR

MAT9540044

PB B B A A XXX

PVC

MAT9750503

PB B B A A XXX

PVC

MAT9560042

(4 G 4,0+(2x1,5)C)C

PB B B A A XXX

PUR

MAT9540042

(4 G 4,0+(2x1,5)C)C

PB B B F A XXX

PVC

MAT9750506

(4 G 4,0+(2x1,5)C)C

PB B B F A XXX

PVC

MAT9560045

(4 G 4,0+(2x1,5)C)C

PB B B F A XXX

PUR

MAT9540045

PB B G A A XXX

PVC

MAT9750501

PB B G A A XXX

PVC

MAT9560040

(4 G 1,5+(2x1,5)C)C

PB B G A A XXX

PUR

MAT9540040

(4 G 1,5+(2x1,5)C)C

PB B G F A XXX

PVC

MAT9750504

(4 G 1,5+(2x1,5)C)C

PB B G F A XXX

PVC

MAT9560043

(4 G 1,5+(2x1,5)C)C

PB B G F A XXX

PUR

MAT9540043

(4 G 1,5+(2x1,5)C)C

13,5

Basic cable PB B A A B XXX

PVC

MAT9750508

(4 G 2,5+(2x1,5)C)C

13,5

10

4

PB B D B B XXX

PUR

MAT9540062

(4 G 10,0+(2x1,5)C)C

21,5

7,5

7

PB B A A B XXX

PVC

MAT9560047

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

PB B D F B XXX

PVC

MAT9560056

(4 G 10,0+(2x1,5)C)C

22,5

7,5

5

PB B A A B XXX

PUR

MAT9540047

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

PB B D F B XXX

PUR

MAT9540056

(4 G 10,0+(2x1,5)C)C

21,5

7,5

7

PB B A B B XXX

PVC

MAT9750516

(4 G 2,5+(2x1,5)C)C

13,5

10

4

PB B D G B XXX

PVC

MAT9560068

(4 G 10,0+(2x1,5)C)C

22,5

7,5

5

PB B A B B XXX

PVC

MAT9560059

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

PB B D G B XXX

PUR

MAT9540068

(4 G 10,0+(2x1,5)C)C

21,5

7,5

7

PB B A B B XXX

PUR

MAT9540059

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

PB B E A B XXX

PVC

MAT9560051

(4 G 16,0+(2x1,5)C)C

24,5

7,5

5

PB B A F B XXX

PVC

MAT9750512

(4 G 2,5+(2x1,5)C)C

13,5

10

4

PB B E A B XXX

PUR

MAT9540051

(4 G 16,0+(2x1,5)C)C

24,5

7,5

7

PB B A F B XXX

PVC

MAT9560053

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

PB B E B B XXX

PVC

MAT9560063

(4 G 16,0+(2x1,5)C)C

24,5

7,5

5

PB B A F B XXX

PUR

MAT9540053

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

PB B E B B XXX

PUR

MAT9540063

(4 G 16,0+(2x1,5)C)C

24,5

7,5

7

PB B A G B XXX

PVC

MAT9750520

(4 G 2,5+(2x1,5)C)C

13,5

10

4

PB B E F B XXX

PVC

MAT9560057

(4 G 16,0+(2x1,5)C)C

24,5

7,5

5

PB B A G B XXX

PVC

MAT9560065

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

PB B E F B XXX

PUR

MAT9540057

(4 G 16,0+(2x1,5)C)C

24,5

7,5

7

PB B A G B XXX

PUR

MAT9540065

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

PB B E G B XXX

PVC

MAT9560069

(4 G 16,0+(2x1,5)C)C

24,5

7,5

5

PB B B A B XXX

PVC

MAT9750509

(4 G 4,0+(2x1,5)C)C

15,0

10

4

PB B E G B XXX

PUR

MAT9540069

(4 G 16,0+(2x1,5)C)C

24,5

7,5

7

PB B B A B XXX

PVC

MAT9560048

(4 G 4,0+(2x1,5)C)C

15,5

7,5

5

PB B B A B XXX

PUR

MAT9540048

(4 G 4,0+(2x1,5)C)C

16,0

7,5

7

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 382

Page 334-337

Harnessed according to Control Techniques standard (PVC-/PUR-Servo cable) Page

Basic cable MAT9750502

26

Control T. readycable® PVC/PUR

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

383


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:12 Seite 384

Control T. readycable® PVC/PUR/TPE

Control Techniques harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

Danaher Motion harnessed drive cables ... optionally with PVC-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Control Techniques standard (PVC-/PUR-Servo cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page 334-337

Harnessed according to Danaher Motion standard (PVC-/TPE-Power cable) Page

bending

334

radius [x d]

to 337

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

PB B G A B XXX

PVC

MAT9750507

(4 G 1,5+(2x1,5)C)C

12,0

10

4

PB B G A B XXX

PVC

MAT9560046

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

PB B G A B XXX

PUR

MAT9540046

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

PB B G B B XXX

PVC

MAT9750515

(4 G 1,5+(2x1,5)C)C

12,0

10

4

89918 (5 m)

PVC

MAT9340068

(4 G 1,5)C

10,5

7,5

1

PB B G B B XXX

PVC

MAT9560058

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

89918 (5 m)

TPE

MAT9440068

(4 G 1,5)C

9,5

7,5

2

PB B G B B XXX

PUR

MAT9540058

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

89918 (5 m)

TPE

MAT9960621

(4 G 1,5)C

9,5

7,5

3

PB B G F B XXX

PVC

MAT9750511

(4 G 1,5+(2x1,5)C)C

12,0

10

4

89952 (10 m)

PVC

MAT9340069

(4 G 1,5)C

10,5

7,5

1

PB B G F B XXX

PVC

MAT9560052

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

89952 (10 m)

TPE

MAT9440069

(4 G 1,5)C

9,5

7,5

2

PB B G F B XXX

PUR

MAT9540052

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

89952 (10 m)

TPE

MAT9960622

(4 G 1,5)C

9,5

7,5

3

PB B G G B XXX

PVC

MAT9750519

(4 G 1,5+(2x1,5)C)C

12,0

10

4

89953 (15 m)

PVC

MAT9340070

(4 G 1,5)C

10,5

7,5

1

PB B G G B XXX

PVC

MAT9560064

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

89953 (15 m)

TPE

MAT9440070

(4 G 1,5)C

9,5

7,5

2

PB B G G B XXX

PUR

MAT9540064

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

89953 (15 m)

TPE

MAT9960623

(4 G 1,5)C

9,5

7,5

3

89954 (20 m)

PVC

MAT9340071

(4 G 1,5)C

10,5

7,5

1

89954 (20 m)

TPE

MAT9440071

(4 G 1,5)C

9,5

7,5

2

89954 (20 m)

TPE

MAT9960624

(4 G 1,5)C

9,5

7,5

3

89956 (25 m)

PVC

MAT9340072

(4 G 1,5)C

10,5

7,5

1

Harnessed according to Control Techniques standard (PVC-/PUR-/TPE-Encoder cable)

Basic cable

Basic cable

SS B A H C XXX

PVC

MAT9560100

(4x(2x0,34)+4x0,5)C

9,0

10

8

89956 (25 m)

TPE

MAT9440072

(4 G 1,5)C

9,5

7,5

2

SS B A H C XXX

PUR

MAT9840501

(4x(2x0,34)+4x0,5)C

10,5

10

9

89956 (25 m)

TPE

MAT9960625

(4 G 1,5)C

9,5

7,5

3

SS B A H C XXX

TPE

MAT9540100

(4x(2x0,34)+4x0,5)C

10,5

10

11

89959 (5 m)

PVC

MAT9340004

(4 G 2,5)C

12,0

7,5

1

SS B A H H XXX

PVC

MAT9560101

(4x(2x0,34)+4x0,5)C

9,0

10

8

89959 (5 m)

TPE

MAT9440004

(4 G 2,5)C

11,0

7,5

2

SS B A H H XXX

PUR

MAT9840502

(4x(2x0,34)+4x0,5)C

10,5

10

9

88959 (5 m)

TPE

MAT9960626

(4 G 2,5)C

11,5

7,5

3

SS B A H H XXX

TPE

MAT9540101

(4x(2x0,34)+4x0,5)C

10,5

10

11

89960 (10 m)

PVC

MAT9340073

(4 G 2,5)C

12,0

7,5

1

SS B A H N XXX

PVC

MAT9560104

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

9,0

10

8

89960 (10 m)

TPE

MAT9440073

(4 G 2,5)C

11,5

7,5

2

SS B A H N XXX

PUR

MAT9840505

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

10,5

10

9

88960 (10 m)

TPE

MAT9960627

(4 G 2,5)C

11,5

7,5

3

SS B A H N XXX

TPE

MAT9540104

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

10,5

10

11

89962 (15 m)

PVC

MAT9340074

(4 G 2,5)C

12,0

7,5

1

89962 (15 m)

TPE

MAT9440074

(4 G 2,5)C

11,5

7,5

2

88962 (15 m)

TPE

MAT9960628

(4 G 2,5)C

11,5

7,5

3

89964 (20 m)

PVC

MAT9340075

(4 G 2,5)C

12,0

7,5

1

89964 (20 m)

TPE

MAT9440075

(4 G 2,5)C

11,5

7,5

2

88964 (20 m)

TPE

MAT9960629

(4 G 2,5)C

11,5

7,5

3

89966 (25 m)

PVC

MAT9340076

(4 G 2,5)C

12,0

7,5

1

89966 (25 m)

TPE

MAT9440076

(4 G 2,5)C

11,5

7,5

2

88966 (25 m)

TPE

MAT9960630

(4 G 2,5)C

11,5

7,5

3

90083 (5 m)

PVC

MAT9340063

(4 G 1,5)C

10,5

7,5

1

90083 (5 m)

TPE

MAT9440063

(4 G 1,5)C

9,5

7,5

2

90083 (5 m)

TPE

MAT9960616

(4 G 1,5)C

9,5

7,5

3

90084 (10 m)

PVC

MAT9340064

(4 G 1,5)C

10,5

7,5

1

90084 (10 m)

TPE

MAT9440064

(4 G 1,5)C

9,5

7,5

2

90084 (10 m)

TPE

MAT9960617

(4 G 1,5)C

9,5

7,5

3

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 384

26

Danaher M. readycable® PVC/TPE

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

385


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:12 Seite 386

Danaher M. readycable® PVC/TPE

Danaher Motion harnessed drive cables ... optionally with PVC-/TPE-jacket

Danaher Motion harnessed drive cables ... optionally with PVC-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Danaher Motion standard (PVC-/TPE-Power cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page 334-337

Harnessed according to Danaher Motion standard (PVC-/TPE-Power cable) Page

bending

334

radius [x d]

to 337

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

90085 (15 m)

PVC

MAT9340065

(4 G 1,5)C

10,5

7,5

1

107476 (20 m)

PVC

MAT9340056

(4 G 1,5)C

10,5

7,5

1

90085 (15 m)

TPE

MAT9440065

(4 G 1,5)C

9,5

7,5

2

107476 (20 m)

TPE

MAT9440056

(4 G 1,5)C

9,5

7,5

2

90085 (15 m)

TPE

MAT9960618

(4 G 1,5)C

9,5

7,5

3

107476 (20 m)

TPE

MAT9960609

(4 G 1,5)C

9,5

7,5

3

90086 (20 m)

PVC

MAT9340066

(4 G 1,5)C

10,5

7,5

1

107477 (25 m)

PVC

MAT9340057

(4 G 1,5)C

10,5

7,5

1

90086 (20 m)

TPE

MAT9440066

(4 G 1,5)C

9,5

7,5

2

107477 (25 m)

TPE

MAT9440057

(4 G 1,5)C

9,5

7,5

2

90086 (20 m)

TPE

MAT9960619

(4 G 1,5)C

9,5

7,5

3

107477 (25 m)

TPE

MAT9960610

(4 G 1,5)C

9,5

7,5

3

90087 (25 m)

PVC

MAT9340067

(4 G 1,5)C

10,5

7,5

1

90087 (25 m)

TPE

MAT9440067

(4 G 1,5)C

9,5

7,5

2

90087 (25 m)

TPE

MAT9960620

(4 G 1,5)C

9,5

7,5

3 107485 (5 m)

PVC

MAT9340002

(4 G 1,5)C

10,5

7,5

1

107485 (5 m)

TPE

MAT9440002

(4 G 1,5)C

9,5

7,5

2

107485 (5 m)

TPE

MAT9960601

(4 G 1,5)C

9,5

7,5

3

Basic cable

Basic cable

102575 (5 m)

PVC

MAT9340058

(4 G 1,5)C

10,5

7,5

1

107486 (10 m)

PVC

MAT9340049

(4 G 1,5)C

10,5

7,5

1

102575 (5 m)

TPE

MAT9440058

(4 G 1,5)C

9,5

7,5

2

107486 (10 m)

TPE

MAT9440049

(4 G 1,5)C

9,5

7,5

2

102575 (5 m)

TPE

MAT9960611

(4 G 1,5)C

9,5

7,5

3

107486 (10 m)

TPE

MAT9960602

(4 G 1,5)C

9,5

7,5

3

102576 (10 m)

PVC

MAT9340059

(4 G 1,5)C

10,5

7,5

1

107487 (15 m)

PVC

MAT9340050

(4 G 1,5)C

10,5

7,5

1

102576 (10 m)

TPE

MAT9440059

(4 G 1,5)C

9,5

7,5

2

107487 (15 m)

TPE

MAT9440050

(4 G 1,5)C

9,5

7,5

2

102576 (10 m)

TPE

MAT9960612

(4 G 1,5)C

9,5

7,5

3

107487 (15 m)

TPE

MAT9960603

(4 G 1,5)C

9,5

7,5

3

102806 (15 m)

PVC

MAT9340060

(4 G 1,5)C

10,5

7,5

1

107488 (20 m)

PVC

MAT9340051

(4 G 1,5)C

10,5

7,5

1

102806 (15 m)

TPE

MAT9440060

(4 G 1,5)C

9,5

7,5

2

107488 (20 m)

TPE

MAT9440051

(4 G 1,5)C

9,5

7,5

2

102806 (15 m)

TPE

MAT9960613

(4 G 1,5)C

9,5

7,5

3

107488 (20 m)

TPE

MAT9960604

(4 G 1,5)C

9,5

7,5

3

102807 (20 m)

PVC

MAT9340061

(4 G 1,5)C

10,5

7,5

1

107489 (25 m)

PVC

MAT9340052

(4 G 1,5)C

10,5

7,5

1

102807 (20 m)

TPE

MAT9440061

(4 G 1,5)C

9,5

7,5

2

107489 (25 m)

TPE

MAT9440052

(4 G 1,5)C

9,5

7,5

2

102807 (20 m)

TPE

MAT9960614

(4 G 1,5)C

9,5

7,5

3

107489 (25 m)

TPE

MAT9960605

(4 G 1,5)C

9,5

7,5

3

102808 (25 m)

PVC

MAT9340062

(4 G 1,5)C

10,5

7,5

1

102808 (25 m)

TPE

MAT9440062

(4 G 1,5)C

9,5

7,5

2

102808 (25 m)

TPE

MAT9960615

(4 G 1,5)C

9,5

7,5

3 200456 (5 m)

PVC

MAT9340077

(4 G 1,5)C

10,5

7,5

1

200456 (5 m)

TPE

MAT9440077

(4 G 1,5)C

9,5

7,5

2

200456 (5 m)

TPE

MAT9960631

(4 G 1,5)C

9,5

7,5

3

Basic cable

Basic cable

107473 (5 m)

PVC

MAT9340053

(4 G 1,5)C

10,5

7,5

1

200457 (10 m)

PVC

MAT9340078

(4 G 1,5)C

10,5

7,5

1

107473 (5 m)

TPE

MAT9440053

(4 G 1,5)C

9,5

7,5

2

200457 (10 m)

TPE

MAT9440078

(4 G 1,5)C

9,5

7,5

2

107473 (5 m)

TPE

MAT9960606

(4 G 1,5)C

9,5

7,5

3

200457 (10 m)

TPE

MAT9960632

(4 G 1,5)C

9,5

7,5

3

107474 (10 m)

PVC

MAT9340054

(4 G 1,5)C

10,5

7,5

1

200458 (15 m)

PVC

MAT9340079

(4 G 1,5)C

10,5

7,5

1

107474 (10 m)

TPE

MAT9440054

(4 G 1,5)C

9,5

7,5

2

200458 (15 m)

TPE

MAT9440079

(4 G 1,5)C

9,5

7,5

2

107474 (10 m)

TPE

MAT9960607

(4 G 1,5)C

9,5

7,5

3

200458 (15 m)

TPE

MAT9960633

(4 G 1,5)C

9,5

7,5

3

107475 (15 m)

PVC

MAT9340055

(4 G 1,5)C

10,5

7,5

1

200459 (20 m)

PVC

MAT9340080

(4 G 1,5)C

10,5

7,5

1

107475 (15 m)

TPE

MAT9440055

(4 G 1,5)C

9,5

7,5

2

200459 (20 m)

TPE

MAT9440080

(4 G 1,5)C

9,5

7,5

2

107475 (15 m)

TPE

MAT9960608

(4 G 1,5)C

9,5

7,5

3

200459 (20 m)

TPE

MAT9960634

(4 G 1,5)C

9,5

7,5

3

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 386

26

Danaher M. readycable® PVC/TPE

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

387


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:12 Seite 388

Danaher M. readycable® PVC/TPE

Danaher Motion harnessed drive cables ... optionally with PVC-/TPE-jacket

Danaher Motion harnessed drive cables ... optionally with PVC-/PUR-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Danaher Motion standard (PVC-/TPE-Power cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page 334-337

Harnessed according to Danaher Motion standard (PVC-/PUR-Servo cable) Page

bending

334

radius [x d]

to 337

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø

Minimum

Page

bending

334

radius [x d]

to 337

12,0

10

4

[mm]

200460 (25 m)

PVC

MAT9340081

(4 G 1,5)C

10,5

7,5

1

200460 (25 m)

TPE

MAT9440081

(4 G 1,5)C

9,5

7,5

2

200460 (25 m)

TPE

MAT9960635

(4 G 1,5)C

9,5

7,5

3

200468 (5 m)

PVC

MAT9340082

(4 G 2,5)C

12,0

7,5

1

89957 (5 m)

PVC

200468 (5 m)

TPE

MAT9440082

(4 G 2,5)C

11,5

7,5

2

89957 (5 m)

PVC

MAT9340024

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

200468 (5 m)

TPE

MAT9960636

(4 G 2,5)C

11,5

7,5

3

89957 (5 m)

PUR

MAT9850621

(4 G 1,5+(2x1,5)C)C

12,0

10

6

200469 (10 m)

PVC

MAT9340083

(4 G 2,5)C

12,0

7,5

1

89957 (5 m)

PUR

MAT9440024

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

200469 (10 m)

TPE

MAT9440083

(4 G 2,5)C

11,5

7,5

2

89961 (10 m)

PVC

MAT9750622

(4 G 1,5+(2x1,5)C)C

12,0

10

4

200469 (10 m)

TPE

MAT9960637

(4 G 2,5)C

11,5

7,5

3

89961 (10 m)

PVC

MAT9340025

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

200470 (15 m)

PVC

MAT9340084

(4 G 2,5)C

12,0

7,5

1

89961 (10 m)

PUR

MAT9850622

(4 G 1,5+(2x1,5)C)C

12,0

10

6

200470 (15 m)

TPE

MAT9440084

(4 G 2,5)C

11,5

7,5

2

89961 (10 m)

PUR

MAT9440025

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

200470 (15 m)

TPE

MAT9960638

(4 G 2,5)C

11,5

7,5

3

89963 (15 m)

PVC

MAT9750623

(4 G 1,5+(2x1,5)C)C

12,0

10

4

200471 (20 m)

PVC

MAT9340085

(4 G 2,5)C

12,0

7,5

1

89963 (15 m)

PVC

MAT9340026

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

200471 (20 m)

TPE

MAT9440085

(4 G 2,5)C

11,5

7,5

2

89963 (15 m)

PUR

MAT9850623

(4 G 1,5+(2x1,5)C)C

12,0

10

6

200471 (20 m)

TPE

MAT9960639

(4 G 2,5)C

11,5

7,5

3

89963 (15 m)

PUR

MAT9440026

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

200472 (25 m)

PVC

MAT9340086

(4 G 2,5)C

12,0

7,5

1

89965 (20 m)

PVC

MAT9750624

(4 G 1,5+(2x1,5)C)C

12,0

10

4

200472 (25 m)

TPE

MAT9440086

(4 G 2,5)C

11,5

7,5

2

89965 (20 m)

PVC

MAT9340027

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

200472 (25 m)

TPE

MAT9960640

(4 G 2,5)C

11,5

7,5

3

89965 (20 m)

PUR

MAT9850624

(4 G 1,5+(2x1,5)C)C

12,0

10

6

200618 (5 m)

PVC

MAT9340087

(4 G 4,0)C

13,5

7,5

1

89965 (20 m)

PUR

MAT9440027

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

200618 (5 m)

TPE

MAT9440087

(4 G 4,0)C

13,5

7,5

2

89967 (25 m)

PVC

MAT9750625

(4 G 1,5+(2x1,5)C)C

12,0

10

4

200618 (5 m)

TPE

MAT9960641

(4 G 4,0)C

13,5

7,5

3

89967 (25 m)

PVC

MAT9340028

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

200619 (10 m)

PVC

MAT9340088

(4 G 4,0)C

13,5

7,5

1

89967 (25 m)

PUR

MAT9850625

(4 G 1,5+(2x1,5)C)C

12,0

10

6

200619 (10 m)

TPE

MAT9440088

(4 G 4,0)C

13,5

7,5

2

89967 (25 m)

PUR

MAT9440028

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

200619 (10 m)

TPE

MAT9960642

(4 G 4,0)C

13,5

7,5

3

89968 (5 m)

PVC

MAT9750626

(4 G 2,5+(2x1,5)C)C

13,5

10

4

200620 (15 m)

PVC

MAT9340089

(4 G 4,0)C

13,5

7,5

1

89968 (5 m)

PVC

MAT9340029

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

200620 (15 m)

TPE

MAT9440089

(4 G 4,0)C

13,5

7,5

2

89968 (5 m)

PUR

MAT9850626

(4 G 2,5+(2x1,5)C)C

13,5

10

6

200620 (15 m)

TPE

MAT9960643

(4 G 4,0)C

13,5

7,5

3

89968 (5 m)

PUR

MAT9440029

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

200621 (20 m)

PVC

MAT9340090

(4 G 4,0)C

13,5

7,5

1

89970 (10 m)

PVC

MAT9750627

(4 G 2,5+(2x1,5)C)C

13,5

10

4

200621 (20 m)

TPE

MAT9440090

(4 G 4,0)C

13,5

7,5

2

89970 (10 m)

PVC

MAT9340030

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

200621 (20 m)

TPE

MAT9960644

(4 G 4,0)C

13,5

7,5

3

89970 (10 m)

PUR

MAT9850627

(4 G 2,5+(2x1,5)C)C

13,5

10

6

Basic cable MAT9750621

(4 G 1,5+(2x1,5)C)C

200622 (25 m)

PVC

MAT9340091

(4 G 4,0)C

13,5

7,5

1

89970 (10 m)

PUR

MAT9440030

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

200622 (25 m)

TPE

MAT9440091

(4 G 4,0)C

13,5

7,5

2

89971 (15 m)

PVC

MAT9750628

(4 G 2,5+(2x1,5)C)C

13,5

10

4

200622 (25 m)

TPE

MAT9960645

(4 G 4,0)C

13,5

7,5

3

89971 (15 m)

PVC

MAT9340031

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

89971 (15 m)

PUR

MAT9850628

(4 G 2,5+(2x1,5)C)C

13,5

10

6

89971 (15 m)

PUR

MAT9440031

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

89972 (20 m)

PVC

MAT9750629

(4 G 2,5+(2x1,5)C)C

13,5

10

4

89972 (20 m)

PVC

MAT9340032

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

89972 (20 m)

PUR

MAT9850629

(4 G 2,5+(2x1,5)C)C

13,5

10

6

89972 (20 m)

PUR

MAT9440032

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 388

26

Danaher M. readycable® PVC/PUR

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

389


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:12 Seite 390

Danaher M. readycable® PVC/PUR

Danaher Motion harnessed drive cables ... optionally with PVC-/PUR-jacket

Danaher Motion harnessed drive cables ... optionally with PVC-/PUR-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Danaher Motion standard (PVC-/PUR-Servo cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page 334-337

Harnessed according to Danaher Motion standard (PVC-/PUR-Servo cable) Page

bending

334

radius [x d]

to 337

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

89969 (25 m)

PVC

MAT9750630

(4 G 2,5+(2x1,5)C)C

13,5

10

4

102810 (20 m)

PVC

MAT9750614

(4 G 1,5+(2x1,5)C)C

12,0

10

4

89969 (25 m)

PVC

MAT9340033

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

102810 (20 m)

PVC

MAT9340017

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

89969 (25 m)

PUR

MAT9850630

(4 G 2,5+(2x1,5)C)C

13,5

10

6

102810 (20 m)

PUR

MAT9850614

(4 G 1,5+(2x1,5)C)C

12,0

10

6

89969 (25 m)

PUR

MAT9440033

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

102810 (20 m)

PUR

MAT9440017

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

90088 (5 m)

PVC

MAT9750616

(4 G 1,5+(2x1,5)C)C

12,0

10

4

102811 (25 m)

PVC

MAT9750615

(4 G 1,5+(2x1,5)C)C

12,0

10

4

90088 (5 m)

PVC

MAT9340019

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

102811 (25 m)

PVC

MAT9340018

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

90088 (5 m)

PUR

MAT9850616

(4 G 1,5+(2x1,5)C)C

12,0

10

6

102811 (25 m)

PUR

MAT9850615

(4 G 1,5+(2x1,5)C)C

12,0

10

6

90088 (5 m)

PUR

MAT9440019

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

102811 (25 m)

PUR

MAT9440018

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

90089 (10 m)

PVC

MAT9750617

(4 G 1,5+(2x1,5)C)C

12,0

10

4

90089 (10 m)

PVC

MAT9340020

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

90089 (10 m)

PUR

MAT9850617

(4 G 1,5+(2x1,5)C)C

12,0

10

6

90089 (10 m)

PUR

MAT9440020

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

107479 (5 m)

PVC

MAT9340009

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

90090 (15 m)

PVC

MAT9750618

(4 G 1,5+(2x1,5)C)C

12,0

10

4

107479 (5 m)

PVC

MAT9750606

(4 G 1,5+(2x1,5)C)C

12,0

10

4

90090 (15 m)

PVC

MAT9340021

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

107479 (5 m)

PUR

MAT9850606

(4 G 1,5+(2x1,5)C)C

12,0

10

6

90090 (15 m)

PUR

MAT9850618

(4 G 1,5+(2x1,5)C)C

12,0

10

6

107479 (5 m)

PUR

MAT9440009

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

90090 (15 m)

PUR

MAT9440021

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

107480 (10 m)

PVC

MAT9340010

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

90091 (20 m)

PVC

MAT9750619

(4 G 1,5+(2x1,5)C)C

12,0

10

4

107480 (10 m)

PVC

MAT9750607

(4 G 1,5+(2x1,5)C)C

12,0

10

4

90091 (20 m)

PVC

MAT9340022

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

107480 (10 m)

PUR

MAT9850607

(4 G 1,5+(2x1,5)C)C

12,0

10

6

90091 (20 m)

PUR

MAT9850619

(4 G 1,5+(2x1,5)C)C

12,0

10

6

107480 (10 m)

PUR

MAT9440010

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

90091 (20 m)

PUR

MAT9440022

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

107481 (15 m)

PVC

MAT9340011

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

90092 (25 m)

PVC

MAT9750620

(4 G 1,5+(2x1,5)C)C

12,0

10

4

107481 (15 m)

PVC

MAT9750608

(4 G 1,5+(2x1,5)C)C

12,0

10

4

90092 (25 m)

PVC

MAT9340023

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

107481 (15 m)

PUR

MAT9850608

(4 G 1,5+(2x1,5)C)C

12,0

10

6

90092 (25 m)

PUR

MAT9850620

(4 G 1,5+(2x1,5)C)C

12,0

10

6

107481 (15 m)

PUR

MAT9440011

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

90092 (25 m)

PUR

MAT9440023

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

107482 (20 m)

PVC

MAT9340012

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

107482 (20 m)

PVC

MAT9750609

(4 G 1,5+(2x1,5)C)C

12,0

10

4

107482 (20 m)

PUR

MAT9850609

(4 G 1,5+(2x1,5)C)C

12,0

10

6

Basic cable 102579 (5 m)

PVC

MAT9750611

102579 (5 m)

PVC

MAT9340014

102579 (5 m)

PUR

MAT9850611

Basic cable

107482 (20 m)

PUR

MAT9440012

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

12,0

10

4

107483 (25 m)

PVC

MAT9340013

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

107483 (25 m)

PVC

MAT9750610

(4 G 1,5+(2x1,5)C)C

12,0

10

4

(4 G 1,5+(2x1,5)C)C

12,0

10

6

107483 (25 m)

PUR

MAT9850610

(4 G 1,5+(2x1,5)C)C

12,0

10

6

107483 (25 m)

PUR

MAT9440013

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

(4 G 1,5+(2x1,5)C)C

102579 (5 m)

PUR

MAT9440014

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

102580 (10 m)

PVC

MAT9750612

(4 G 1,5+(2x1,5)C)C

12,0

10

4

102580 (10 m)

PVC

MAT9340015

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

102580 (10 m)

PUR

MAT9850612

(4 G 1,5+(2x1,5)C)C

12,0

10

6

102580 (10 m)

PUR

MAT9440015

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

107491 (5 m)

PVC

MAT9750601

(4 G 1,5+(2x1,5)C)C

12,0

10

4

102809 (15 m)

PVC

MAT9750613

(4 G 1,5+(2x1,5)C)C

12,0

10

4

107491 (5 m)

PVC

MAT9340001

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

102809 (15 m)

PVC

MAT9340016

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

107491 (5 m)

PUR

MAT9850601

(4 G 1,5+(2x1,5)C)C

12,0

10

6

102809 (15 m)

PUR

MAT9850613

(4 G 1,5+(2x1,5)C)C

12,0

10

6

107491 (5 m)

PUR

MAT9440001

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

102809 (15 m)

PUR

MAT9440016

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

107492 (10 m)

PVC

MAT9750602

(4 G 1,5+(2x1,5)C)C

12,0

10

4

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 390

26

Danaher M. readycable® PVC/PUR

(for up to 10 cuts of the same type)

Basic cable

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

391


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:12 Seite 392

Danaher M. readycable® PVC/PUR

Danaher Motion harnessed drive cables ... optionally with PVC-/PUR-jacket

Danaher Motion harnessed drive cables ... optionally with PVC-/PUR-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Danaher Motion standard (PVC-/PUR-Servo cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page 334-337

Harnessed according to Danaher Motion standard (PVC-/PUR-Servo cable) Page

bending

334

radius [x d]

to 337

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

107492 (10 m)

PVC

MAT9340005

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

200474 (5 m)

PVC

MAT9340039

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

107492 (10 m)

PUR

MAT9850602

(4 G 1,5+(2x1,5)C)C

12,0

10

6

200474 (5 m)

PUR

MAT9850636

(4 G 2,5+(2x1,5)C)C

13,5

10

6

107492 (10 m)

PUR

MAT9440005

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

200474 (5 m)

PUR

MAT9440039

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

107493 (15 m)

PVC

MAT9750603

(4 G 1,5+(2x1,5)C)C

12,0

10

4

200475 (10 m)

PVC

MAT9750637

(4 G 2,5+(2x1,5)C)C

13,5

10

4

107493 (15 m)

PVC

MAT9340006

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

200475 (10 m)

PVC

MAT9340040

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

107493 (15 m)

PUR

MAT9850603

(4 G 1,5+(2x1,5)C)C

12,0

10

6

200475 (10 m)

PUR

MAT9850637

(4 G 2,5+(2x1,5)C)C

13,5

10

6

107493 (15 m)

PUR

MAT9440006

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

200475 (10 m)

PUR

MAT9440040

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

107494 (20 m)

PVC

MAT9750604

(4 G 1,5+(2x1,5)C)C

12,0

10

4

200476 (15 m)

PVC

MAT9750638

(4 G 2,5+(2x1,5)C)C

13,5

10

4

107494 (20 m)

PVC

MAT9340007

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

200476 (15 m)

PVC

MAT9340041

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

107494 (20 m)

PUR

MAT9850604

(4 G 1,5+(2x1,5)C)C

12,0

10

6

200476 (15 m)

PUR

MAT9850638

(4 G 2,5+(2x1,5)C)C

13,5

10

6

107494 (20 m)

PUR

MAT9440007

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

200476 (15 m)

PUR

MAT9440041

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

107495 (25 m)

PVC

MAT9750605

(4 G 1,5+(2x1,5)C)C

12,0

10

4

200477 (20 m)

PVC

MAT9750639

(4 G 2,5+(2x1,5)C)C

13,5

10

4

107495 (25 m)

PVC

MAT9340008

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

200477 (20 m)

PVC

MAT9340042

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

107495 (25 m)

PUR

MAT9850605

(4 G 1,5+(2x1,5)C)C

12,0

10

6

200477 (20 m)

PUR

MAT9850639

(4 G 2,5+(2x1,5)C)C

13,5

10

6

107495 (25 m)

PUR

MAT9440008

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

200477 (20 m)

PUR

MAT9440042

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

200478 (25 m)

PVC

MAT9750640

(4 G 2,5+(2x1,5)C)C

13,5

10

4

200478 (25 m)

PVC

MAT9340043

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

200478 (25 m)

PUR

MAT9850640

(4 G 2,5+(2x1,5)C)C

13,5

10

6

Basic cable 200462 (5 m)

PVC

MAT9750631

(4 G 1,5+(2x1,5)C)C

12,0

10

4

200478 (25 m)

PUR

MAT9440043

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

200462 (5 m)

PVC

MAT9340034

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

200623 (5 m)

PVC

MAT9750641

(4 G 4,0+(2x1,5)C)C

15,0

10

4

200462 (5 m)

PUR

MAT9850631

(4 G 1,5+(2x1,5)C)C

12,0

10

6

200623 (5 m)

PVC

MAT9340044

(4 G 4,0+(2x1,5)C)C

15,5

7,5

5

200462 (5 m)

PUR

MAT9440034

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

200623 (5 m)

PUR

MAT9850641

(4 G 4,0+(2x1,5)C)C

15,0

10

6

200463 (10 m)

PVC

MAT9750632

(4 G 1,5+(2x1,5)C)C

12,0

10

4

200623 (5 m)

PUR

MAT9440044

(4 G 4,0+(2x1,5)C)C

16,0

7,5

7

200463 (10 m)

PVC

MAT9340035

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

200624 (10 m)

PVC

MAT9750642

(4 G 4,0+(2x1,5)C)C

15,0

10

4

200463 (10 m)

PUR

MAT9850632

(4 G 1,5+(2x1,5)C)C

12,0

10

6

200624 (10 m)

PVC

MAT9340045

(4 G 4,0+(2x1,5)C)C

15,5

7,5

5

200463 (10 m)

PUR

MAT9440035

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

200624 (10 m)

PUR

MAT9850642

(4 G 4,0+(2x1,5)C)C

15,0

10

6

200464 (15 m)

PVC

MAT9750633

(4 G 1,5+(2x1,5)C)C

12,0

10

4

200624 (10 m)

PUR

MAT9440045

(4 G 4,0+(2x1,5)C)C

16,0

7,5

7

200464 (15 m)

PVC

MAT9340036

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

200625 (15 m)

PVC

MAT9750643

(4 G 4,0+(2x1,5)C)C

15,0

10

4

200464 (15 m)

PUR

MAT9850633

(4 G 1,5+(2x1,5)C)C

12,0

10

6

200625 (15 m)

PVC

MAT9340046

(4 G 4,0+(2x1,5)C)C

15,5

7,5

5

200464 (15 m)

PUR

MAT9440036

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

200625 (15 m)

PUR

MAT9850643

(4 G 4,0+(2x1,5)C)C

15,0

10

6

200465 (20 m)

PVC

MAT9750634

(4 G 1,5+(2x1,5)C)C

12,0

10

4

200625 (15 m)

PUR

MAT9440046

(4 G 4,0+(2x1,5)C)C

16,0

7,5

7

200465 (20 m)

PVC

MAT9340037

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

200626 (20 m)

PVC

MAT9750644

(4 G 4,0+(2x1,5)C)C

15,0

10

4

200465 (20 m)

PUR

MAT9850634

(4 G 1,5+(2x1,5)C)C

12,0

10

6

200626 (20 m)

PVC

MAT9340047

(4 G 4,0+(2x1,5)C)C

15,5

7,5

5

200465 (20 m)

PUR

MAT9440037

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

200626 (20 m)

PUR

MAT9850644

(4 G 4,0+(2x1,5)C)C

15,0

10

6

200466 (25 m)

PVC

MAT9750635

(4 G 1,5+(2x1,5)C)C

12,0

10

4

200626 (20 m)

PUR

MAT9440047

(4 G 4,0+(2x1,5)C)C

16,0

7,5

7

200466 (25 m)

PVC

MAT9340038

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

200627 (25 m)

PVC

MAT9750645

(4 G 4,0+(2x1,5)C)C

15,0

10

4

200466 (25 m)

PUR

MAT9850635

(4 G 1,5+(2x1,5)C)C

12,0

10

6

200627 (25 m)

PVC

MAT9340048

(4 G 4,0+(2x1,5)C)C

15,5

7,5

5

200466 (25 m)

PUR

MAT9440038

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

200627 (25 m)

PUR

MAT9850645

(4 G 4,0+(2x1,5)C)C

15,0

10

6

200474 (5 m)

PVC

MAT9750636

(4 G 2,5+(2x1,5)C)C

13,5

10

4

200627 (25 m)

PUR

MAT9440048

(4 G 4,0+(2x1,5)C)C

16,0

7,5

7

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 392

26

Danaher M. readycable® PVC/PUR

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

393


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:12 Seite 394

Danaher M. readycable® PVC/PUR/TPE

Danaher Motion harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

Danaher Motion harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Danaher Motion standard (PVC-/PUR-/TPE-Signal cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page 334-337

Harnessed according to Danaher Motion standard (PVC-/PUR-/TPE-Signal cable) Page

bending

334

radius [x d]

to 337

Basic cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

Basic cable

84972 (5 m)

PVC

MAT9320001

(4x(2x0,25))C

8,0

10

14

85034 (5 m)

PVC

MAT9320007

(6x(2x0,25))C

9,5

10

14

84972 (5 m) 84972 (5 m)

PUR

MAT9840601

(4x(2x0,25))C

9,0

10

15

85034 (5 m)

PUR

MAT9840606

(6x(2x0,25))C

10,0

10

15

TPE

MAT9330001

(4x(2x0,25))C

9,0

10

16

85034 (5 m)

TPE

MAT9330007

(6x(2x0,25))C

10,0

10

16

84973 (10 m)

PVC

MAT9320009

(4x(2x0,25))C

84973 (10 m)

PUR

MAT9840602

(4x(2x0,25))C

8,0

10

14

85035 (10 m)

PVC

MAT9320021

(6x(2x0,25))C

9,5

10

14

9,0

10

15

85035 (10 m)

PUR

MAT9840607

(6x(2x0,25))C

10,0

10

15

84973 (10 m)

TPE

MAT9330009

(4x(2x0,25))C

84974 (15 m)

PVC

MAT9320010

(4x(2x0,25))C

9,0

10

16

85035 (10 m)

TPE

MAT9330021

(6x(2x0,25))C

10,0

10

16

8,0

10

14

85036 (15 m)

PVC

MAT9320022

(6x(2x0,25))C

9,5

10

14

84974 (15 m)

PUR

MAT9840603

84974 (15 m)

TPE

MAT9330010

(4x(2x0,25))C

9,0

10

15

85036 (15 m)

PUR

MAT9840608

(6x(2x0,25))C

10,0

10

15

(4x(2x0,25))C

9,0

10

16

85036 (15 m)

TPE

MAT9330022

(6x(2x0,25))C

10,0

10

16

84975 (20 m)

PVC

MAT9320011

(4x(2x0,25))C

84975 (20 m)

PUR

MAT9840604

(4x(2x0,25))C

8,0

10

14

85037 (20 m)

PVC

MAT9320023

(6x(2x0,25))C

9,5

10

14

9,0

10

15

85037 (20 m)

PUR

MAT9840609

(6x(2x0,25))C

10,0

10

15

84975 (20 m)

TPE

MAT9330011

(4x(2x0,25))C

87655 (25 m)

PVC

MAT9320012

(4x(2x0,25))C

9,0

10

16

85037 (20 m)

TPE

MAT9330023

(6x(2x0,25))C

10,0

10

16

8,0

10

14

87655 (25 m)

PUR

MAT9840605

87655 (25 m)

TPE

MAT9330012

(4x(2x0,25))C

9,0

10

15

(4x(2x0,25))C

9,0

10

16

90287 (5 m)

PVC

MAT9320002

(8x(2x0,25))C

90287 (5 m)

TPE

MAT9330002

(8x(2x0,34))C

11,5

10

14

85039 (5 m)

PVC

MAT9320008

(6x(2x0,25))C

9,5

10

14

12,5

10

16

85039 (5 m)

PUR

MAT9840610

(6x(2x0,25))C

10,0

10

15

91019 (10 m)

PVC

MAT9320013

(8x(2x0,25))C

91019 (10 m)

TPE

MAT9330013

(8x(2x0,34))C

11,5

10

14

85039 (5 m)

TPE

MAT9330008

(6x(2x0,25))C

10,0

10

16

12,5

10

16

85040 (10 m)

PVC

MAT9320024

(6x(2x0,25))C

9,5

10

14

91807 (20 m)

PVC

MAT9320015

(8x(2x0,25))C

91807 (20 m)

TPE

MAT9330015

(8x(2x0,34))C

11,5

10

14

85040 (10 m)

PUR

MAT9840611

(6x(2x0,25))C

10,0

10

15

12,5

10

16

85040 (10 m)

TPE

MAT9330024

(6x(2x0,25))C

10,0

10

16

91811 (15 m)

PVC

MAT9320014

(8x(2x0,25))C

91811 (15 m)

TPE

MAT9330014

(8x(2x0,34))C

11,5

10

14

85041 (15 m)

PVC

MAT9320025

(6x(2x0,25))C

9,5

10

14

12,5

10

16

85041 (15 m)

PUR

MAT9840612

(6x(2x0,25))C

10,0

10

15

92205 (25 m)

PVC

MAT9320016

(8x(2x0,25))C

92205 (25 m)

TPE

MAT9330016

(8x(2x0,34))C

11,5

10

14

85041 (15 m)

TPE

MAT9330025

(6x(2x0,25))C

10,0

10

16

12,5

10

16

85042 (20 m)

PVC

MAT9320026

(6x(2x0,25))C

9,5

10

14

107915 (5 m)

PVC

MAT9320004

(8x(2x0,25))C

107915 (5 m)

TPE

MAT9330004

(8x(2x0,34))C

11,5

10

14

85042 (20 m)

PUR

MAT9840613

(6x(2x0,25))C

10,0

10

15

12,5

10

16

85042 (20 m)

TPE

MAT9330026

(6x(2x0,25))C

10,0

10

16

107916 (10 m)

PVC

MAT9320017

(8x(2x0,25))C

11,5

10

14

107916 (10 m)

TPE

MAT9330017

(8x(2x0,34))C

12,5

10

16

107917 (15 m)

PVC

MAT9320018

(8x(2x0,25))C

11,5

10

14

107917 (15 m)

TPE

MAT9330018

(8x(2x0,34))C

12,5

10

16

107918 (20 m)

PVC

MAT9320019

(8x(2x0,25))C

11,5

10

14

107918 (20 m)

TPE

MAT9330019

(8x(2x0,34))C

12,5

10

16

107919 (25 m)

PVC

MAT9320020

(8x(2x0,25))C

11,5

10

14

107919 (25 m)

TPE

MAT9330020

(8x(2x0,34))C

12,5

10

16

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 394

26

Danaher M. readycable® PVC/PUR/TPE

(for up to 10 cuts of the same type)

Basic cable

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

395


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:13 Seite 396

ELAU readycable® PVC/PUR

ELAU harnessed drive cables ... optionally with PVC-/PUR-jacket

ELAU harnessed drive cables ... optionally with PVC-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to ELAU standard (PVC-/PUR-Servo cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

26

ELAU readycable® PVC/TPE

Page 334-337

Harnessed according to ELAU standard (PVC-/TPE-Encoder cable) Minimum

Page

bending

334

radius [x d]

to 337

Basic cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

Basic cable

E-MO-067

PVC

MAT9750701

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

E-FB-060

PVC

MAT9480001

(4x(2x0,25)+2x0,5)C

9,0

10

8

E-MO-067

PVC

MAT9470001

E-MO-067

PUR

MAT9850701

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

E-FB-060

TPE

MAT9480101

(4x(2x0,25)+2x0,5)C

9,5

10

11

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

E-FB-071

PVC

MAT9480002

(4x(2x0,25)+2x0,5)C

9,0

10

8

E-MO-067

PUR

MAT9470101

E-MO-092

PVC

MAT9750704

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

E-FB-071

TPE

MAT9940702

(4x(2x0,25)+2x0,5)C

9,5

10

9

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

E-FB-071

TPE

MAT9480102

(4x(2x0,25)+2x0,5)C

9,5

10

11

E-MO-092

PVC

MAT9470004

E-MO-092

PUR

MAT9850704

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

E-MO-092

PUR

MAT9470104

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7 E-FB-080

PVC

MAT9480003

(4x(2x0,25)+2x0,5)C

9,0

10

8

E-FB-080

TPE

MAT9940703

(4x(2x0,25)+2x0,5)C

9,5

10

9

E-FB-080

TPE

MAT9480103

(4x(2x0,25)+2x0,5)C

9,5

10

11

Basic cable E-MO-087

PVC

MAT9750703

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

E-MO-087

PVC

MAT9470003

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

E-MO-087

PUR

MAT9850703

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

E-MO-087

PUR

MAT9470103

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

E-MO-111 SH-Motor 1.5 PVC

MAT9750702

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

Basic cable

Basic cable

E-MO-111 SH-Motor 1.5 PVC

MAT9470002

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

E-MO-111 SH-Motor 1.5 PUR

MAT9850702

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

E-MO-111 SH-Motor 1.5 PUR

MAT9470102

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

E-MO-113 SH-Motor 2.5 PVC

MAT9750705

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

E-MO-113 SH-Motor 2.5 PVC

MAT9470005

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

Basic cable

E-MO-113 SH-Motor 2.5 PUR

MAT9850705

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

E-MO-113 SH-Motor 2.5 PUR

MAT9470105

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 396

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

397


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:13 Seite 398

Fagor readycable® PUR/TPE

Fagor harnessed drive cables ... optionally with PUR-/TPE-jacket

Fagor harnessed drive cables ... optionally with PUR-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Fagor standard (PUR-/TPE-Path measurement cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

26

Fagor readycable® PUR/TPE

Page 334-337

Harnessed according to Fagor standard (PUR-/TPE-Path measurement cable) Page

bending

334

radius [x d]

to 337

Extension cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

Extension cable

iEEC-x

PUR

MAT9850808

(4x(2x0,14)+4x0,5)C

9,5

10

9

iXC-C8-FN

PUR

MAT9850806

(4x(2x0,14)+4x0,5)C

9,5

10

9

iEEC-x

TPE

MAT9950808

(4x(2x0,14)+4x0,5)C

8,0

12

10

iXC-C8-FN

TPE

MAT9950806

(4x(2x0,14)+4x0,5)C

8,0

12

10

iEEC-x

TPE

MAT9520070

(4x(2x0,14)+4x0,5)C

9,5

10

11

iXC-C8-FN

TPE

MAT9520050

(4x(2x0,14)+4x0,5)C

9,5

10

11

Extension cable

Extension cable

iXC-C2-D

PUR

MAT9850801

(4x(2x0,14)+4x0,5)C

9,5

10

9

iXC-C2-FN2

PUR

MAT9850807

(4x(2x0,14)+4x0,5)C

9,5

10

9

iXC-C2-D

TPE

MAT9950801

(4x(2x0,14)+4x0,5)C

8,0

12

10

iXC-C2-FN2

TPE

MAT9950807

(4x(2x0,14)+4x0,5)C

8,0

12

10

iXC-C2-D

TPE

MAT9520001

(4x(2x0,14)+4x0,5)C

9,5

10

11

iXC-C2-FN2

TPE

MAT9520060

(4x(2x0,14)+4x0,5)C

9,5

10

11

iXC-C4-D

PUR

MAT9850802

(4x(2x0,14)+4x0,5)C

9,5

10

9

iXC-C4-D

TPE

MAT9950802

(4x(2x0,14)+4x0,5)C

8,0

12

10

iXC-C4-D

TPE

MAT9520010

(4x(2x0,14)+4x0,5)C

9,5

10

11

iXC-C2-H

PUR

MAT9850803

(4x(2x0,14)+4x0,5)C

9,5

10

9

iXC-C2-H

TPE

MAT9950803

(4x(2x0,14)+4x0,5)C

8,0

12

10

iXC-C2-H

TPE

MAT9520020

(4x(2x0,14)+4x0,5)C

9,5

10

11

iXC-C8-F-D

PUR

MAT9850804

(2x(2x2x0,14)+(4x0,14)C+(4x0,5))C

11,5

10

9

iXC-C8-F-D

TPE

MAT9950804

(4x(2x0,14)+(4x0,14)C+4x0,5)C

10,5

12

10

iXC-C8-F-D

TPE

MAT9520030

(2x(2x2x0,14)+(4x0,14)C+(4x0,5))C

11,5

10

11

iXC-C8-F-C9

PUR

MAT9850805

(2x(2x2x0,14)+(4x0,14)C+(4x0,5))C

11,5

10

9

iXC-C8-F-C9

TPE

MAT9950805

(4x(2x0,14)+(4x0,14)C+4x0,5)C

10,5

12

10

iXC-C8-F-C9

TPE

MAT9520040

(2x(2x2x0,14)+(4x0,14)C+(4x0,5))C

11,5

10

11

Extension cable

Extension cable

Extension cable

Extension cable

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 398

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

399


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:13 Seite 400

Fanuc readycable® PVC/PUR/TPE

Fanuc harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

Fanuc harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Fanuc standard (PVC-/PUR-/TPE-Power cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Page 334-337

Harnessed according to Fanuc standard (PVC-/PUR-/TPE-Power cable)

Minimum

Page

bending

334

radius [x d]

to 337

Basic cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

7,5

1

Basic cable

LX660-8077-T261

PVC

MAT9760901

(4 G 1,5)C

10,5

7,5

1

LX660-8077-T271

PVC

MAT9760907

(4 G 4,0)C

13,5

LX660-8077-T261

PUR

MAT9200061

(4 G 1,5)C

LX660-8077-T261

PUR

MAT9210061

(4 G 1,5)C

9,0

10

6

LX660-8077-T271

PUR

MAT9200071

(4 G 4,0)C

12,5

10

6

10,5

7,5

7

LX660-8077-T271

PUR

MAT9210071

(4 G 4,0+(2x1,5)C)C

16,0

7,5

7

LX660-8077-T261

TPE

MAT9960901

(4 G 1,5)C

9,5

7,5

2

LX660-8077-T271

TPE

MAT9960907

(4 G 4,0)C

13,5

7,5

2

LX660-8077-T272

PVC

MAT9760908

(4 G 10,0)C

21,0

7,5

1

LX660-8077-T272

PUR

MAT9200072

(4 G 10,0)C

18,0

10

6

LX660-8077-T272

PUR

MAT9210072

(4 G 10,0+(2x1,5)C)C

21,5

7,5

7

Basic cable LX660-8077-T264

PVC

MAT9760902

(4 G 2,5)C

12,0

7,5

1

LX660-8077-T272

TPE

MAT9960908

(4 G 10,0)C

19,5

7,5

2

LX660-8077-T264

PUR

MAT9200064

(4 G 2,5)C

11,0

10

6

LX660-8077-T273

PVC

MAT9760909

(4 G 10,0)C

21,0

7,5

1

LX660-8077-T264

PUR

MAT9210064

(4 G 2,5)C

12,5

7,5

7

LX660-8077-T273

PUR

MAT9200073

(4 G 10,0)C

18,0

10

6

LX660-8077-T264

TPE

MAT9960902

(4 G 2,5)C

11,5

7,5

2

LX660-8077-T273

PUR

MAT9210073

(4 G 10,0+(2x1,5)C)C

21,5

7,5

7

LX660-8077-T266

PVC

MAT9760904

(4 G 2,5)C

12,0

7,5

1

LX660-8077-T273

TPE

MAT9960909

(4 G 10,0)C

19,5

7,5

2

LX660-8077-T266

PUR

MAT9200066

(4 G 2,5)C

11,0

10

6

LX660-8077-T266

PUR

MAT9210066

(4 G 2,5)C

12,5

7,5

7

LX660-8077-T266

TPE

MAT9960904

(4 G 2,5)C

11,5

7,5

2

Basic cable

Basic cable LX660-8077-T291

PVC

MAT9760910

(4 G 2,5)C

12,0

7,5

1

LX660-8077-T291

PUR

MAT9200091

(4 G 2,5)C

11,0

10

6

LX660-8077-T291

PUR

MAT9210091

(4 G 2,5)C

12,5

7,5

7

7,5

1

LX660-8077-T291

TPE

MAT9960910

(4 G 2,5)C

11,5

7,5

2

11,0

10

6

LX660-8077-T293

PVC

MAT9760912

(4 G 4,0)C

13,5

7,5

1

12,5

7,5

7

LX660-8077-T293

PUR

MAT9200093

(4 G 4,0)C

12,5

10

6

(4 G 2,5)C

11,5

7,5

2

LX660-8077-T293

PUR

MAT9210093

(4 G 4,0+(2x1,5)C)C

16,0

7,5

7

(4 G 2,5)C

12,0

7,5

1

LX660-8077-T293

TPE

MAT9960912

(4 G 4,0)C

13,5

7,5

2

MAT9200067

(4 G 2,5)C

11,0

10

6

MAT9210067

(4 G 2,5)C

12,5

7,5

7

MAT9960905

(4 G 2,5)C

11,5

7,5

2 LX660-8077-T292

PVC

MAT9760911

(4 G 4,0)C

13,5

7,5

1

LX660-8077-T292

PUR

MAT9200092

(4 G 4,0)C

12,5

10

6

LX660-8077-T292

PUR

MAT9210092

(4 G 4,0+(2x1,5)C)C

16,0

7,5

7

LX660-8077-T292

TPE

MAT9960911

(4 G 4,0)C

13,5

7,5

2

LX660-8077-T265

PVC

MAT9760903

(4 G 2,5)C

12,0

LX660-8077-T265

PUR

MAT9200065

(4 G 2,5)C

LX660-8077-T265

PUR

MAT9210065

(4 G 2,5)C

LX660-8077-T265

TPE

MAT9960903

LX660-8077-T267

PVC

MAT9760905

LX660-8077-T267

PUR

LX660-8077-T267

PUR

LX660-8077-T267

TPE

Basic cable LX660-8077-T270

PVC

MAT9760906

(4 G 4,0)C

13,5

7,5

1

LX660-8077-T270

PUR

MAT9200070

(4 G 4,0)C

12,5

10

6

LX660-8077-T270

PUR

MAT9210070

(4 G 4,0+(2x1,5)C)C

16,0

7,5

7

LX660-8077-T270

TPE

MAT9960906

(4 G 4,0)C

13,5

7,5

2

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 400

26

Fanuc readycable® PVC/PUR/TPE

(for up to 10 cuts of the same type)

Basic cable

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

401


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:13 Seite 402

Fanuc readycable® PVC/PUR/TPE

Fanuc harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

Fanuc harnessed drive cables ... optionally with PUR-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Fanuc standard (PVC-/PUR-/TPE-Power cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

26

Fanuc readycable® PUR/TPE

Page 334-337

Harnessed according to Fanuc standard (PUR-/TPE-Signal cable)

Minimum

Page

bending

334

radius [x d]

to 337

Basic cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

Basic cable

LX660-8077-T296

PVC

MAT9760913

(4 G 2,5)C

12,0

7,5

1

LX660-4077-T296

PUR

MAT9840901

(5x0,5+(2x0,25))C

8,5

12

9

LX660-8077-T296

PUR

MAT9200096

(4 G 2,5)C

LX660-8077-T296

PUR

MAT9210096

(4 G 2,5)C

11,0

10

6

LX660-4077-T296

TPE

MAT9300296

(5x0,5+(2x0,25))C

8,0

12

10

12,5

7,5

7

LX660-4077-T296

TPE

MAT9310296

(5x0,5+(2x0,25))C

8,5

10

11

LX660-8077-T296

TPE

MAT9960913

(4 G 2,5)C

11,5

7,5

2

LX660-4077-T297

PUR

MAT9840902

(5x0,5+(2x0,25))C

8,5

12

9

Basic cable Basic cable LX660-8077-T298

PVC

MAT9760914

(4 G 4,0)C

13,5

7,5

1

LX660-4077-T297

TPE

MAT9300297

(5x0,5+(2x0,25))C

8,0

12

10

LX660-8077-T298

PUR

MAT9200098

(4 G 4,0)C

12,5

10

6

LX660-4077-T297

TPE

MAT9310297

(5x0,5+(2x0,25))C

8,5

10

11

LX660-8077-T298

PUR

MAT9210098

(4 G 4,0+(2x1,5)C)C

16,0

7,5

7

LX660-8077-T298

TPE

MAT9960914

(4 G 4,0)C

13,5

7,5

2

LX660-4077-T302

PUR

MAT9840903

(3x(2x0,5+2x0,25)+(4x0,25))C

11,0

12

9

LX660-4077-T302

TPE

MAT9300302

(6x0,5+5x2x0,25)C

10,0

12

10

LX660-4077-T302

TPE

MAT9310302

(3x(2x0,5+2x0,25)+(4x0,25))C

11,0

10

11

LX660-4077-T303

PUR

MAT9840904

(3x(2x0,5+2x0,25)+(4x0,25))C

11,0

12

9

LX660-4077-T303

TPE

MAT9300303

(6x0,5+5x2x0,25)C

10,0

12

10

LX660-4077-T303

TPE

MAT9310303

(3x(2x0,5+2x0,25)+(4x0,25))C

11,0

10

11

LX660-4077-T319

PUR

MAT9840905

(3x(2x0,5+2x0,25)+(4x0,25))C

11,0

12

9

LX660-4077-T319

TPE

MAT9300319

(6x0,5+5x2x0,25)C

10,0

12

10

LX660-4077-T319

TPE

MAT9310319

(3x(2x0,5+2x0,25)+(4x0,25))C

11,0

10

11

Basic cable LX660-8077-T300

PVC

MAT9760915

(4 G 2,5)C

12,0

7,5

1

LX660-8077-T300

PUR

MAT9200300

(4 G 2,5)C

LX660-8077-T300

PUR

MAT9210300

(4 G 2,5)C

11,0

10

6

12,5

7,5

7

LX660-8077-T300

TPE

MAT9960915

(4 G 2,5)C

11,5

7,5

2

Basic cable

Basic cable

Basic cable

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 402

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

403


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:13 Seite 404

Heidenhain readycable® PVC/PUR

Heidenhain harnessed drive cables ... optionally with PVC-/PUR-jacket

Heidenhain harnessed drive cables ... optionally with PUR-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Heidenhain standard (PVC-/PUR-Servo cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

26

Heidenhain readycable® PUR/TPE

Page 334-337

Harnessed according to Heidenhain standard (PUR-/TPE-Adapter cable)

Minimum

Page

bending

334

radius [x d]

to 337

Connecting cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

Connecting cable

352 960-xx

PVC

MAT94907005 (4 G 1,5+(2x1,5)C)C

12,0

10

4

298 399-xx

PUR

MAT94905001 (4x(2x0,14)+4x0,5)C

9,5

10

9

352 960-xx

PVC

MAT9761001

352 960-xx

PUR

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

298 399-xx

TPE

MAT9941011

(4x(2x0,14)+4x0,5)C

8,0

12

10

MAT93907005 (4 G 1,5+(2x1,5)C)C

12,0

10

6

298 399-xx

TPE

MAT93905001 (4x(2x0,14)+4x0,5)C

9,5

10

11

352 960-xx

PUR

MAT9861001

352 963-xx

PVC

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

298 400-xx

PUR

MAT94906002 (4x(2x0,14)+4x0,5)C

9,5

10

9

MAT94907006 (4 G 2,5+(2x1,5)C)C

13,5

10

4

298 400-xx

TPE

MAT9941012

(4x(2x0,14)+4x0,5)C

8,0

12

10

352 963-xx

PVC

MAT9761002

352 963-xx

PUR

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

298 400-xx

TPE

MAT93906002 (4x(2x0,14)+4x0,5)C

9,5

10

11

MAT93907006 (4 G 2,5+(2x1,5)C)C

13,5

10

6

289 440-xx

PVC

MAT9741002

(4x(2x0,14)+4x1,0+(4x0,14)C)C

9,0

10

8

352 963-xx

PUR

MAT9861002

352 962-xx

PVC

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

289 440-xx

PUR

MAT94901005 (4x(2x0,14)+4x1,0+(4x0,14)C)C

11,5

12

9

MAT94907007 (4 G 1,5+(2x1,5)C)C

12,0

10

4

289 440-xx

TPE

MAT93901005 (4x(2x0,14)+4x1,0+(4x0,14)C)C

11,5

12

11

352 962-xx

PVC

MAT9761003

352 962-xx

PUR

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

309 783-xx

PUR

MAT94903003 (4x(2x0,14)+4x0,5)C

9,5

12

9

MAT93907007 (4 G 1,5+(2x1,5)C)C

12,0

10

6

309 783-xx

TPE

MAT9941008

(4x(2x0,14)+4x0,5)C

8,0

12

10

352 962-xx

PUR

MAT9861003

13,0

7,5

7

309 783-xx

TPE

MAT93903003 (4x(2x0,14)+4x0,5)C

9,5

12

11

336 376-xx

PVC

MAT9741001

(4x(2x0,14)+4x1,0+(4x0,14)C)C

9,0

10

8

336 376-xx

PUR

MAT94901004 (4x(2x0,14)+4x1,0+(4x0,14)C)C

11,5

12

9

336 376-xx

TPE

MAT93901004 (4x(2x0,14)+4x1,0+(4x0,14)C)C

11,5

12

11

604 419-xx

PUR

MAT94901003 (4x(2x0,14)+4x0,5)C

9,5

12

9

604 419-xx

TPE

MAT9941003

(4x(2x0,14)+4x0,5)C

8,0

12

10

604 419-xx

TPE

MAT93901003 (4x(2x0,14)+4x0,5)C

9,5

12

11

298 402-xx

PUR

MAT94909001 (4x(2x0,14)+4x0,5)C

9,5

10

9

298 402-xx

TPE

MAT9941016

(4x(2x0,14)+4x0,5)C

8,0

12

10

298 402-xx

TPE

MAT93909001 (4x(2x0,14)+4x0,5)C

9,5

10

11

309 738-xx

PUR

MAT94903001 (4x(2x0,14)+4x0,5)C

9,5

10

9

309 738-xx

TPE

MAT9941007

(4x(2x0,14)+4x0,5)C

8,0

12

10

309 738-xx

TPE

MAT93903001 (4x(2x0,14)+4x0,5)C

9,5

10

11

(4 G 1,5+(2x1,5)C)C

Connecting cable

Connecting cable

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 404

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

405


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:13 Seite 406

Heidenhain readycable® PUR/TPE

Heidenhain harnessed drive cables ... optionally with PUR-/TPE-jacket

Heidenhain harnessed drive cables ... optionally with PUR-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Heidenhain standard (PUR-/TPE-Adapter cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

26

Heidenhain readycable® PUR/TPE

Page 334-337

Harnessed according to Heidenhain standard (PUR-/TPE-Adapter cable)

Minimum

Page

bending

334

radius [x d]

to 337

Connecting cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

Connecting cable

309 774-xx

PUR

MAT94906001 (4x(2x0,14)+4x0,5)C

9,5

10

9

324 544-xx

PUR

MAT94902002 (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C

11,5

10

9

309 774-xx

TPE

MAT93906001 (4x(2x0,14)+4x0,5)C

9,5

10

11

324 544-xx

TPE

MAT9941005

10,5

12

10

368 172-xx

PVC

MAT9741003

(3x(2x0,14)C+(2x0,5C))C

9,0

10

8

324 544-xx

TPE

MAT93902002 (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C

11,5

10

11

368 172-xx

PUR

MAT94903002 (3x(2x0,14)C+(2x0,5C))C

10,5

12

9

368 172-xx

TPE

MAT93903002 (3x(2x0,14)C+(2x0,5C))C

11,5

12

11

332 115-xx

PUR

MAT94901001 (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C

11,5

10

9

332 115-xx

TPE

MAT9941001

10,5

12

10

332 115-xx

TPE

MAT93901001 (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C

11,5

10

11

Connecting cable

(4x(2x0,14)+(4x0,14)C+4x0,5)C

Connecting cable

(4x(2x0,14)+(4x0,14)C+4x0,5)C

309 777-xx

PUR

MAT94907001 (4x(2x0,14)+4x0,5)C

9,5

10

9

309 777-xx

TPE

MAT9941013

(4x(2x0,14)+4x0,5)C

8,0

12

10

309 777-xx

TPE

MAT93907001 (4x(2x0,14)+4x0,5)C

9,5

10

11

309 778-xx

PUR

MAT94907002 (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C

11,5

10

9

309 778-xx

TPE

MAT9941014

10,5

12

10

335 077-xx

PUR

MAT94908001 (4x(2x0,14)+4x0,5)C

9,5

10

9

309 778-xx

TPE

MAT93907002 (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C

11,5

10

11

335 077-xx

TPE

MAT93908001 (4x(2x0,14)+4x0,5)C

9,5

10

11

533 627-xx

PUR

MAT94901006 (4x(2x0,14)+4x0,5)C

9,5

12

9

533 627-xx

TPE

MAT9941004

(4x(2x0,14)+4x0,5)C

8,0

12

10

533 627-xx

TPE

MAT93901006 (4x(2x0,14)+4x0,5)C

9,5

12

11 354 411-xx

PUR

MAT94904001 (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C

11,5

10

9

354 411-xx

TPE

MAT9941009

10,5

12

10

(4x(2x0,14)+(4x0,14)C+4x0,5)C

Connecting cable

Connecting cable

Connecting cable

(4x(2x0,14)+(4x0,14)C+4x0,5)C

354 411-xx

TPE

MAT93904001 (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C

11,5

10

11

310 193-xx

PUR

MAT94907003 (3x(2x0,14)C+(2x0,5)C)C

11,0

10

9

355 398-xx

PUR

MAT94904002 (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C

11,5

10

9

310 193-xx

TPE

MAT93907003 (3x(2x0,14)C+(2x0,5)C)C

10,5

10

11

355 398-xx

TPE

MAT9941010

10,5

12

10

355 398-xx

TPE

MAT93904002 (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C

11,5

10

11

(4x(2x0,14)+(4x0,14)C+4x0,5)C

Connecting cable Connecting cable 310 197-xx

PUR

MAT94902001 (3x(2x0,14)C+(2x0,5)C)C

11,0

10

9

310 197-xx

TPE

MAT93902001 (3x(2x0,14)C+(2x0,5)C)C

10,5

10

11

360 472-xx

PUR

MAT94901002 (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C

11,5

10

9

10,5

12

10

11,5

10

11

310 199-xx

PUR

MAT94902003 (4x(2x0,14)+4x0,5)C

9,5

10

9

360 472-xx

TPE

MAT9941002

310 199-xx

TPE

MAT9941006

8,0

12

10

360 472-xx

TPE

MAT93901002 (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C

310 199-xx

TPE

MAT93902003 (4x(2x0,14)+4x0,5)C

9,5

10

11

323 897-xx

PUR

MAT94907004 (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C

11,5

10

9

323 897-xx

TPE

MAT9941015

10,5

12

10

323 897-xx

TPE

MAT93907004 (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C

11,5

10

11

(4x(2x0,14)+(4x0,5))C

(4x(2x0,14)+(4x0,14)C+4x0,5)C

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 406

(for up to 10 cuts of the same type)

(4x(2x0,14)+(4x0,14)C+4x0,5)C

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

407


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:13 Seite 408

Jetter readycable® PVC/PUR/TPE

Jetter harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

Jetter harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Jetter standard (PVC-/PUR-/TPE-Power cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Page 334-337

Harnessed according to Jetter standard (PVC-/PUR-/TPE-Resolver cable)

Minimum

Page

bending

334

radius [x d]

to 337

Basic cable

Manufacturer

Jacket material

Part No.

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

Basic cable

Kabel Nr. 201

PVC

MAT9761805

(4 G 4,0)C

13,5

Kabel Nr. 201

PUR

MAT9861806

(4 G 4,0)C

Kabel Nr. 201

PUR

MAT9851807

(4 G 4,0+(2x1,5)C)C

Kabel Nr. 201

TPE

MAT9961808

Kabel Nr. 203

PVC

MAT9761809

Kabel Nr. 203

PUR

Kabel Nr. 203

PUR

Kabel Nr. 203 Kabel Nr. 26.1 Kabel Nr. 26.1 Kabel Nr. 26.1 Kabel Nr. 26.1

26

Jetter readycable® PVC/PUR/TPE

7,5

1

Kabel Nr. 523

PVC

MAT9741807

(5x(2x0,25))C

8,5

10

14

12,5

10

6

Kabel Nr. 523

PUR

MAT9841808

(5 x (2 x 0,25))C

9,5

10

15

16,0

7,5

7

Kabel Nr. 523

TPE

MAT9941809

(5x(2x0,25))C

9,0

10

16

(4 G 4,0)C

13,5

7,5

2

Kabel Nr. 723

PVC

MAT9741810

(5x(2x0,25))C

8,5

10

14

(4 G 4,0)C

13,5

7,5

1

Kabel Nr. 723

PUR

MAT9841811

(5 x (2 x 0,25))C

9,5

10

15

MAT9861810

(4 G 4,0)C

12,5

10

6

Kabel Nr. 723

TPE

MAT9941812

(5x(2x0,25))C

9,0

10

16

MAT9851811

(4 G 4,0+(2x1,5)C)C

16,0

7,5

7

TPE

MAT9961812

(4 G 4,0)C

13,5

7,5

2

PVC

MAT9761801

(4 G 1,5)C

10,5

7,5

1

PUR

MAT9861802

(4 G 1,5)C

9,0

10

6

PUR

MAT9851803

(4 G 1,5)C

10,5

7,5

7

Kabel Nr. 23

PVC

MAT9741801

(3x(2x0,14)C+2x(0,5)C)C

9,0

10

TPE

MAT9961804

(4 G 1,5)C

9,5

7,5

2

Kabel Nr. 23

PUR

MAT9841802

(3x(2x0,14)C+(2x0,5)C)C

11,0

10

9

Kabel Nr. 23

TPE

MAT9941803

(3x(2x0,14)C+(2x0,5)C)C

10,5

10

11

Kabel Nr. 423

PVC

MAT9741804

(3x(2x0,14)C+2x(0,5)C)C

9,0

10

8

Kabel Nr. 423

PUR

MAT9841805

(3x(2x0,14)C+(2x0,5)C)C

11,0

10

9

Kabel Nr. 423

TPE

MAT9941806

(3x(2x0,14)C+(2x0,5)C)C

10,5

10

11

Harnessed according to Jetter standard (PVC-/PUR-Servo cable)

Basic cable Kabel Nr. 202

PVC

MAT9751806

(4 G 4,0+(2x1,5)C)C

15,5

7,5

5

Kabel Nr. 202

PUR

MAT9861807

(4 G 4,0+(2x1,5)C)C

Kabel Nr. 202

PUR

MAT9851808

(4 G 4,0+(2x1,5)C)C

15,0

10

6

16,0

7,5

7

Kabel Nr. 204

PVC

MAT9751810

Kabel Nr. 204

PUR

MAT9861811

(4 G 6,0+(2x1,5)C)C

18,0

7,5

5

(4 G 6,0+(2x1,5)C)C

16,5

10

6

Kabel Nr. 204

PUR

MAT9851812

(4 G 6,0+(2x1,5)C)C

17,5

7,5

7

Harnessed according to Jetter standard (PVC-/PUR-/TPE-Resolver cable)

Basic cable 8

Basic cable Kabel Nr. 24.1

PVC

MAT9751802

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

Kabel Nr. 24.1

PUR

MAT9861803

(4 G 1,5+(2x1,5)C)C

12,0

10

6

Kabel Nr. 24.1

PUR

MAT9851804

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 408

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

409


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:13 Seite 410

Lenze readycable® PVC/PUR

Lenze harnessed drive cables ... optionally with PVC-/PUR-jacket

Lenze harnessed drive cables ... optionally with PVC-/PUR-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Lenze standard (PVC-/PUR-Servo cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Page 334-337

Harnessed according to Lenze standard (PVC-/PUR-Servo cable) Minimum

Page

bending

334

radius [x d]

to 337

Basic cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

EYP0012AxxxxM02A00

PVC

MAT9751110

(4 G 2,5+(2x1,5)C)C

13,5

10

4

EYP0012AxxxxM02A00

PVC

MAT9130053

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

EYP0012AxxxxM02A00

PUR

MAT9851108

(4 G 2,5+(2x1,5)C)C

13,5

10

6

12,0

10

4

EYP0012AxxxxM02A00

PUR

MAT9120053

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

EYP0013AxxxxA00P02

PVC

MAT9751114

(4 G 4,0+(2x1,5)C)C

15,0

10

4

(4 G 1,5+(2x1,5)C)C

12,0

10

6

EYP0013AxxxxA00P02

PVC

MAT9130059

(4 G 4,0+(2x1,5)C)C

15,5

7,5

5

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

EYP0013AxxxxA00P02

PUR

MAT9851114

(4 G 4,0+(2x1,5)C)C

15,0

10

6

(4 G 2,5+(2x1,5)C)C

13,5

10

4

EYP0013AxxxxA00P02

PUR

MAT9120059

(4 G 4,0+(2x1,5)C)C

16,0

7,5

7

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

EYP0013AxxxxM02A00

PVC

MAT9751111

(4 G 4,0+(2x1,5)C)C

15,0

10

4

(4 G 2,5+(2x1,5)C)C

13,5

10

6

EYP0013AxxxxM02A00

PVC

MAT9130054

(4 G 4,0+(2x1,5)C)C

15,5

7,5

5

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

EYP0013AxxxxM02A00

PUR

MAT9851109

(4 G 4,0+(2x1,5)C)C

15,0

10

6

(4 G 1,5+(2x1,5)C)C

12,0

10

4

EYP0013AxxxxM02A00

PUR

MAT9120054

(4 G 4,0+(2x1,5)C)C

16,0

7,5

7

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

EYP0014AxxxxA00P03

PVC

MAT9751115

(4 G 6,0+(2x1,5)C)C

16,5

10

4

(4 G 1,5+(2x1,5)C)C

12,0

10

6

EYP0014AxxxxA00P03

PVC

MAT9130060

(4 G 6,0+(2x1,5)C)C

18,0

7,5

5

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

EYP0014AxxxxA00P03

PUR

MAT9851115

(4 G 6,0+(2x1,5)C)C

16,5

10

6

(4 G 1,5+(2x1,5)C)C

12,0

10

4

EYP0014AxxxxA00P03

PUR

MAT9120060

(4 G 6,0+(2x1,5)C)C

17,5

7,5

7

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

EYP0014AxxxxM03A00

PVC

MAT9751112

(4 G 6,0+(2x1,5)C)C

16,5

10

4

(4 G 1,5+(2x1,5)C)C

12,0

10

6

EYP0014AxxxxM03A00

PVC

MAT9130055

(4 G 6,0+(2x1,5)C)C

18,0

7,5

5

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

EYP0014AxxxxM03A00

PUR

MAT9851110

(4 G 6,0+(2x1,5)C)C

18,0

7,5

5

(4 G 1,5+(2x1,5)C)C

12,0

10

4

EYP0014AxxxxM03A00

PUR

MAT9120055

(4 G 6,0+(2x1,5)C)C

17,5

7,5

7

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

EYP0015AxxxxA00P03

PVC

MAT9130061

(4 G 10,0+(2x1,5)C)C

22,5

7,5

5

(4 G 1,5+(2x1,5)C)C

12,0

10

6

EYP0015AxxxxA00P03

PUR

MAT9851116

(4 G 10,0+(2x1,5)C)C

20,5

10

6

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

EYP0015AxxxxA00P03

PUR

MAT9120061

(4 G 10,0+(2x1,5)C)C

21,5

7,5

7

(4 G 1,5+(2x1,5)C)C

12,0

10

4

EYP0015AxxxxM03A00

PVC

MAT9130056

(4 G 10,0+(2x1,5)C)C

22,5

7,5

5

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

EYP0015AxxxxM03A00

PUR

MAT9851111

(4 G 10,0+(2x1,5)C)C

20,5

10

6

(4 G 1,5+(2x1,5)C)C

12,0

10

6

EYP0015AxxxxM03A00

PUR

MAT9120056

(4 G 10,0+(2x1,5)C)C

21,5

7,5

7

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

EYP0016AxxxxA00P03

PVC

MAT9130062

(4 G 16,0+(2x1,5)C)C

24,5

7,5

5

(4 G 2,5+(2x1,5)C)C

13,5

10

4

EYP0016AxxxxA00P03

PUR

MAT9851117

(4 G 16,0+(2x1,5)C)C

24,0

10

6

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

EYP0016AxxxxA00P03

PUR

MAT9120062

(4 G 16,0+(2x1,5)C)C

24,5

7,5

7

(4 G 2,5+(2x1,5)C)C

13,5

10

6

EYP0016AxxxxM03A00

PVC

MAT9130057

(4 G 16,0+(2x1,5)C)C

24,5

7,5

5

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

EYP0016AxxxxM03A00

PUR

MAT9851112

(4 G 16,0+(2x1,5)C)C

24,0

10

6

(4 G 2,5+(2x1,5)C)C

13,5

10

4

EYP0016AxxxxM03A00

PUR

MAT9120057

(4 G 16,0+(2x1,5)C)C

24,5

7,5

7

MAT9130058

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

MAT9851113

(4 G 2,5+(2x1,5)C)C

13,5

10

6

MAT9751103

(4 G 1,5+(2x1,5)C)C

12,0

10

4

EWLMxxxGMS-015C

PVC

MAT9751101

EWLMxxxGMS-015C

PVC

MAT9130001

EWLMxxxGMS-015C

PUR

MAT9851101

EWLMxxxGMS-015C

PUR

MAT9120001

EWLMxxxGMS-025

PVC

MAT9751102

EWLMxxxGMS-025

PVC

MAT9130002

EWLMxxxGMS-025

PUR

MAT9851102

EWLMxxxGMS-025

PUR

MAT9120002

EYP0010AxxxxA00P01

PVC

MAT9751116

EYP0010AxxxxA00P01

PVC

MAT9130063

EYP0010AxxxxA00P01

PUR

MAT9851118

EYP0010AxxxxA00P01

PUR

MAT9120063

EYP0010AxxxxM01A00

PVC

MAT9751107

EYP0010AxxxxM01A00

PVC

MAT9130050

EYP0010AxxxxM01A00

PUR

MAT9851105

EYP0010AxxxxM01A00

PUR

MAT9120050

EYP0011AxxxxA00P01

PVC

MAT9751117

EYP0011AxxxxA00P01

PVC

MAT9130064

EYP0011AxxxxA00P01

PUR

MAT9851119

EYP0011AxxxxA00P01

PUR

MAT9120064

EYP0011AxxxxM01A00

PVC

MAT9751108

EYP0011AxxxxM01A00

PVC

MAT9130051

EYP0011AxxxxM01A00

PUR

MAT9851106

EYP0011AxxxxM01A00

PUR

MAT9120051

EYP0012AxxxxA00P01

PVC

MAT9751118

EYP0012AxxxxA00P01

PVC

MAT9130065

EYP0012AxxxxA00P01

PUR

MAT9851120

EYP0012AxxxxA00P01

PUR

MAT9120065

EYP0012AxxxxA00P02

PVC

MAT9751113

EYP0012AxxxxA00P02

PVC

EYP0012AxxxxA00P02

PUR

(4 G 1,5+(2x1,5)C)C

Linking cable

EYP0012AxxxxA00P02

PUR

MAT9120058

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

EYP0012AxxxxM01A00

PVC

MAT9751109

(4 G 2,5+(2x1,5)C)C

13,5

10

4

EWLMxxxZM-015C

PVC

EYP0012AxxxxM01A00

PVC

MAT9130052

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

EWLMxxxZM-015C

PVC

MAT9130006

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

EYP0012AxxxxM01A00

PUR

MAT9851107

(4 G 2,5+(2x1,5)C)C

13,5

10

6

EWLMxxxZM-015C

PUR

MAT9851103

(4 G 1,5+(2x1,5)C)C

12,0

10

6

EYP0012AxxxxM01A00

PUR

MAT9120052

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

EWLMxxxZM-015C

PUR

MAT9120006

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 410

26

Lenze readycable® PVC/PUR

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

411


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:14 Seite 412

Lenze readycable® PVC/PUR

Lenze harnessed drive cables ... optionally with PVC-/PUR-jacket

Lenze harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Lenze standard (PVC-/PUR-Servo cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Page 334-337

Harnessed according to Lenze standard (PVC-/PUR-/TPE-Resolver cable) Minimum

Page

bending

334

radius [x d]

to 337

Manufacturer

Jacket material

Part No.

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

8

EWLMxxxZM-025

PVC

MAT9751104

(4 G 2,5+(2x1,5)C)C

13,5

10

4

EWLMxxxZM-025

PVC

MAT9130007

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

EWLMxxxZM-025

PUR

MAT9851104

(4 G 2,5+(2x1,5)C)C

13,5

10

6

EWLMxxxZM-025

PUR

MAT9120007

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

EWLRxxxGM-T

PVC

MAT9130021

(3x(2x0,14)C+2x(0,5)C)C

9,0

10

EYP0010VxxxxM01P01

PVC

MAT9751122

(4 G 1,5+(2x1,5)C)C

12,0

10

4

EWLRxxxGM-T

PUR

MAT9841101

(3x(2x0,14)C+(2x0,5)C)C

11,0

12

9

EYP0010VxxxxM01P01

PVC

MAT9130071

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

EWLRxxxGM-T

TPE

MAT9120021

(3x(2x0,14)C+(2x0,5)C)C

10,5

10

11

EYP0010VxxxxM01P01

PUR

MAT9851126

(4 G 1,5+(2x1,5)C)C

12,0

10

6

EYP0010VxxxxM01P01

PUR

MAT9120071

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

EYP0011VxxxxM01P01

PVC

MAT9751123

(4 G 1,5+(2x1,5)C)C

12,0

10

4

EYP0011VxxxxM01P01

PVC

MAT9130072

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

EWLRxxxZMST

PVC

MAT9130022

(3x(2x0,14)C+2x(0,5)C)C

9,0

10

8

EYP0011VxxxxM01P01

PUR

MAT9851127

(4 G 1,5+(2x1,5)C)C

12,0

10

6

EWLRxxxZMST

PUR

MAT9841102

(3x(2x0,14)C+(2x0,5)C)C

11,0

12

9

EYP0011VxxxxM01P01

PUR

MAT9120072

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

EWLRxxxZMST

TPE

MAT9120022

(3x(2x0,14)C+(2x0,5)C)C

10,5

10

11

EYP0012VxxxxM01P01

PVC

MAT9751124

(4 G 2,5+(2x1,5)C)C

13,5

10

4

EYP0012VxxxxM01P01

PVC

MAT9130073

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

EYP0012VxxxxM01P01

PUR

MAT9851128

(4 G 2,5+(2x1,5)C)C

13,5

10

6

EYP0012VxxxxM01P01

PUR

MAT9120073

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

EWLRxxxGX-T

PVC

MAT9130023

(3x(2x0,14)C+2x(0,5)C)C

9,0

10

8

EYP0012VxxxxM02P02

PVC

MAT9751119

(4 G 2,5+(2x1,5)C)C

13,5

10

4

EWLRxxxGX-T

PUR

MAT9841103

(3x(2x0,14)C+(2x0,5)C)C

11,0

12

9

EYP0012VxxxxM02P02

PVC

MAT9130066

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

EWLRxxxGX-T

TPE

MAT9120023

(3x(2x0,14)C+(2x0,5)C)C

10,5

10

11

EYP0012VxxxxM02P02

PUR

MAT9851121

(4 G 2,5+(2x1,5)C)C

13,5

10

6

EYP0012VxxxxM02P02

PUR

MAT9120066

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

EYP0013VxxxxM02P02

PVC

MAT9751120

(4 G 4,0+(2x1,5)C)C

15,0

10

4

EYP0013VxxxxM02P02

PVC

MAT9130067

(4 G 4,0+(2x1,5)C)C

15,5

7,5

5

EYP0013VxxxxM02P02

PUR

MAT9851122

(4 G 4,0+(2x1,5)C)C

15,0

10

6

EWLExxxGM-T

PVC

MAT9130026

(4x(2x0,25)+2x1,0)C

9,5

10

8

EYP0013VxxxxM02P02

PUR

MAT9120067

(4 G 4,0+(2x1,5)C)C

16,0

7,5

7

EWLExxxGM-T

PUR

MAT9841104

(4x(2x0,25)+2x1,0)C

9,5

10

9

EYP0014VxxxxM03P03

PVC

MAT9751121

(4 G 6,0+(2x1,5)C)C

16,5

10

4

EWLExxxGM-T

TPE

MAT9120026

(4x(2x0,25)+2x1,0)C

9,5

10

11

EYP0014VxxxxM03P03

PVC

MAT9130068

(4 G 6,0+(2x1,5)C)C

18,0

7,5

5

EYP0014VxxxxM03P03

PUR

MAT9851123

(4 G 6,0+(2x1,5)C)C

16,5

10

6

EYP0014VxxxxM03P03

PUR

MAT9120068

(4 G 6,0+(2x1,5)C)C

17,5

7,5

7

EYP0015VxxxxM03P03

PVC

MAT9130069

(4 G 10,0+(2x1,5)C)C

22,5

7,5

5

EWLExxxZMST

PVC

MAT9130027

(4x(2x0,25)+2x1,0)C

9,5

10

8

EYP0015VxxxxM03P03

PUR

MAT9851124

(4 G 10,0+(2x1,5)C)C

20,5

10

6

EWLExxxZMST

PUR

MAT9841105

(4x(2x0,25)+2x1,0)C

9,5

10

9

EYP0015VxxxxM03P03

PUR

MAT9120069

(4 G 10,0+(2x1,5)C)C

21,5

7,5

7

EWLExxxZMST

TPE

MAT9120027

(4x(2x0,25)+2x1,0)C

9,5

10

11

EYP0016VxxxxM03P03

PVC

MAT9130070

(4 G 16,0+(2x1,5)C)C

24,5

7,5

5

EYP0016VxxxxM03P03

PUR

MAT9851125

(4 G 16,0+(2x1,5)C)C

24,0

10

6

EYP0016VxxxxM03P03

PUR

MAT9120070

(4 G 16,0+(2x1,5)C)C

24,5

7,5

7

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 412

26

Lenze readycable® PVC/PUR/TPE

(for up to 10 cuts of the same type)

Basic cable

Linking cable

Terminal box connection cable

Harnessed according to Lenze standard (PVC-/PUR-/TPE-Encoder cable)

Basic cable

Linking cable

Terminal box connection cable EWLExxxGX-T

PVC

MAT9130028

(4x(2x0,25)+2x1,0)C

9,5

10

8

EWLExxxGX-T

PUR

MAT9841106

(4x(2x0,25)+2x1,0)C

9,5

10

9

EWLExxxGX-T

TPE

MAT9120028

(4x(2x0,25)+2x1,0)C

9,5

10

11

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

413


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:14 Seite 414

Lenze readycable® PVC/TPE

Lenze harnessed drive cables ... optionally with PVC-/TPE-jacket

Lenze harnessed drive cables ... optionally with PVC-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Lenze standard (PVC-/TPE-Feedback cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

26

Lenze readycable® PVC/TPE

Page 334-337

Harnessed according to Lenze standard (PVC-/TPE-Feedback cable)

Minimum

Page

bending

334

radius [x d]

to 337

Basic cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

Linking cable

EYF0018AxxxxF02S03

PVC

MAT9130088

4x(2x0,14)C+(2x1,0)C

10,0

10

8

EYF0019VxxxxF02G02

PVC

MAT9130084

4x(2x0,14)C+(2x1,0)C

10,0

10

8

EYF0018AxxxxF02S03

TPE

MAT9120088

4x(2x0,14)C+2x(1,0)C

10,0

10

11

EYF0019VxxxxF02G02

TPE

MAT9120084

4x(2x0,14)C+2x(1,0)C

10,0

10

11

EYF0020AxxxxF01S05

PVC

MAT9130090

3x(2x0,14)C+(3x0,14)C

8,0

10

8

EYF0020VxxxxF01G01

PVC

MAT9130083

3x(2x0,14)C+(3x0,14)C

8,0

10

8

EYF0020AxxxxF01S05

TPE

MAT9120090

3x(2x0,14)C+(3x0,14)C

8,0

10

11

EYF0020VxxxxF01G01

TPE

MAT9120083

3x(2x0,14)C+(3x0,14)C

8,0

10

11

EYF0021AxxxxF03S03

PVC

MAT9130086

3x(2x0,14)C+(4x0,14)C+2(2x0,5)C

11,5

10

8

EYF0022VxxxxF03G03

PVC

MAT9130085

3x(2x0,14)C+(4x0,14)C+2(2x0,5)C

11,5

10

8

EYF0021AxxxxF03S03

TPE

MAT9120086

3x(2x0,14)C+(4x0,14)C+2x(2x0,5)C

11,5

10

11

EYF0022VxxxxF03G03

TPE

MAT9120085

3x(2x0,14)C+(4x0,14)C+2x(2x0,5)C

11,5

10

11

Basic cable

Extension cable

EYF0018AxxxxF02W02

PVC

MAT9130087

4x(2x0,14)C+(2x1,0)C

10,0

10

8

EYF0020VxxxxA00G01

PVC

MAT9130080

3x(2x0,14)C+(3x0,14)C

8,0

10

8

EYF0018AxxxxF02W02

TPE

MAT9120087

4x(2x0,14)C+2x(1,0)C

10,0

10

11

EYF0020VxxxxA00G01

TPE

MAT9120080

3x(2x0,14)C+(3x0,14)C

8,0

10

11

EYF0020AxxxxF01S04

PVC

MAT9130089

3x(2x0,14)C+(3x0,14)C

8,0

10

8

EYF0020AxxxxF01S04

TPE

MAT9120089

3x(2x0,14)C+(3x0,14)C

8,0

10

11

EYF0019VxxxxA00G02

PVC

MAT9130081

4x(2x0,14)C+(2x1,0)C

10,0

10

8

Basic cable

Extension cable

EYF0019VxxxxA00G02

TPE

MAT9120081

4x(2x0,14)C+2x(1,0)C

10,0

10

11

EYF0018AxxxxA00W02

PVC

MAT9130091

4x(2x0,14)C+(2x1,0)C

10,0

10

8

EYF0022VxxxxA00G03

PVC

MAT9130082

3x(2x0,14)C+(4x0,14)C+2x(2x0,5)C

11,5

10

8

EYF0018AxxxxA00W02

TPE

MAT9120091

4x(2x0,14)C+2x(1,0)C

10,0

10

11

EYF0022VxxxxA00G03

TPE

MAT9120082

3x(2x0,14)C+(4x0,14)C+2x(2x0,5)C

11,5

10

11

EYF0020AxxxxA00S04

PVC

MAT9130092

3x(2x0,14)C+(3x0,14)C

8,0

10

8

EYF0020AxxxxA00S04

TPE

MAT9120092

3x(2x0,14)C+(3x0,14)C

8,0

10

11

Basic cable EYF0018AxxxxA00S03

PVC

MAT9130095

4x(2x0,14)C+(2x1,0)C

10,0

10

8

EYF0018AxxxxA00S03

TPE

MAT9120095

4x(2x0,14)C+2x(1,0)C

10,0

10

11

EYF0020AxxxxA00S05

PVC

MAT9130093

3x(2x0,14)C+(3x0,14)C

8,0

10

8

EYF0020AxxxxA00S05

TPE

MAT9120093

3x(2x0,14)C+(3x0,14)C

8,0

10

11

EYF0021AxxxxA00S03

PVC

MAT9130094

3x(2x0,14)C+(4x0,14)C+2(2x0,5)C

11,5

10

8

EYF0021AxxxxA00S03

TPE

MAT9120094

3x(2x0,14)C+(4x0,14)C+2x(2x0,5)C

11,5

10

11

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 414

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

415


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:14 Seite 416

Lenze readycable® PVC/PUR/TPE

Lenze harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

Lenze harnessed drive cables ... optionally with PVC-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Lenze standard (PVC-/PUR-/TPE-Decoder cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

26

Lenze readycable® PVC/TPE

Page 334-337

Harnessed according to Lenze standard (PVC-/TPE-Fan cable) Page

bending

334

radius [x d]

to 337

Connecting cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

Basic cable

EYD0017AxxxxW01S01

PVC

MAT9130100

3x(2x0,14)C+(3x0,14)C

8,0

10

8

EWLLxxxGMS

PVC

MAT9761101

EYD0017AxxxxW01S01

PUR

MAT9841107

3x(2x0,14)C+(3x0,14)C

8,0

EYD0017AxxxxW01S01

TPE

MAT9120100

3x(2x0,14)C+(3x0,14)C

8,0

10

9

EWLLxxxGMS

PVC

10

11

EWLLxxxGMS

TPE

EWLLxxxGMS EYL002AxxxxL01A00

Connecting cable

3 G 1,0

7,0

5

17

MAT9130031

3 G 1,0

6,5

7,5

19

MAT9961101

3 G 1,0

7,5

5

26

TPE

MAT9120031

3 G 1,0

6,0

5

24

PVC

MAT9130040

5 G 1,0

9,0

7,5

19

EYL002AxxxxL01A00

TPE

MAT9120040

5 G 1,0

7,0

5

24

8

EYL002AxxxxL02A00

PVC

MAT9130041

5 G 1,0

9,0

7,5

19

10

9

EYL002AxxxxL02A00

TPE

MAT9120041

5 G 1,0

7,0

5

24

10

11

EYD0017AxxxxW01S02

PVC

MAT9130101

3x(2x0,14)C+(3x0,14)C

8,0

10

EYD0017AxxxxW01S02

PUR

MAT9841108

3x(2x0,14)C+(3x0,14)C

8,0

EYD0017AxxxxW01S02

TPE

MAT9120101

3x(2x0,14)C+(3x0,14)C

8,0

Linking cable Connecting cable EWLLxxxZM

PVC

MAT9761102

3 G 1,0

7,0

5

17

8

EWLLxxxZM

PVC

MAT9130032

3 G 1,0

6,5

7,5

19

10

9

EWLLxxxZM

TPE

MAT9961102

3 G 1,0

7,5

5

26

10

11

EWLLxxxZM

TPE

MAT9120032

3 G 1,0

6,0

5

24

EYL002VxxxxL01J01

PVC

MAT9130044

5 G 1,0

9,0

7,5

19

EYL002VxxxxL01J01

TPE

MAT9120044

5 G 1,0

7,0

5

24

EYL002VxxxxL02J02

PVC

MAT9130045

5 G 1,0

9,0

7,5

19

EYL002VxxxxL02J02

TPE

MAT9120045

5 G 1,0

7,0

5

24

EYL002VxxxxA00J01

PVC

MAT9130042

5 G 1,0

9,0

7,5

19

EYL002VxxxxA00J01

TPE

MAT9120042

5 G 1,0

7,0

5

24

EYL002VxxxxA00J02

PUR

MAT9861110

5 G 1,0

8,0

5

21

EYL002VxxxxA00J02

TPE

MAT9961106

5 G 1,0

8,5

5

26

EYL002VxxxxA00J02

PVC

MAT9130043

5 G 1,0

9,0

7,5

19

EYL002VxxxxA00J02

TPE

MAT9120043

5 G 1,0

7,0

5

24

EYD0017AxxxxW03S01

PVC

MAT9130102

3x(2x0,14)C+(3x0,14)C

8,0

10

EYD0017AxxxxW03S01

PUR

MAT9841109

3x(2x0,14)C+(3x0,14)C

8,0

EYD0017AxxxxW03S01

TPE

MAT9120102

3x(2x0,14)C+(3x0,14)C

8,0

Connecting cable EYD0017AxxxxW03S02

PVC

MAT9130103

3x(2x0,14)C+(3x0,14)C

8,0

10

EYD0017AxxxxW03S02

PUR

MAT9841110

3x(2x0,14)C+(3x0,14)C

8,0

10

9

EYD0017AxxxxW03S02

TPE

MAT9120103

3x(2x0,14)C+(3x0,14)C

8,0

10

11

8

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 416

(for up to 10 cuts of the same type)

Extension cable

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

417


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:14 Seite 418

LTi DRiVES readycable® PVC/PUR

LTi DRiVES harnessed drive cables ... optionally with PVC-/PUR-jacket

LTi DRiVES harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to LTi DRiVES standard (PVC-/PUR-Servo cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

26

LTi DRiVES readycable® PVC/PUR/TPE

Page 334-337

Harnessed according to LTi DRiVES standard (PVC-/PUR-/TPE-Encoder cable)

Minimum

Page

bending

334

radius [x d]

to 337

Basic cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

Basic cable

KM3-KSxxx

PVC

MAT9020004

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

KGH2-KSxxx

PVC

MAT9021004

(4x(2x0,25)+2x1,0)C

9,5

10

8

KM3-KSxxx

PVC

MAT9020003

KM3-KSxxx

PUR

MAT9020002

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

KGH2-KSxxx

TPE

MAT9021001

(4x(2x0,25)+2x1,0)C

9,5

10

11

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

KGH3-KSxxx

PVC

MAT9021014

(4x(2x0,25)+2x1,0)C

9,5

10

8

KM3-KSxxx

PUR

MAT9020001

KM3-KSxxx-24A

PVC

MAT9020014

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

KGH3-KSxxx

TPE

MAT9021011

(4x(2x0,25)+2x1,0)C

9,5

10

11

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

KGS2-KSxxx

PUR

MAT9021022

(2x(2x2x0,14)+(4x0,14)C+(4x0,5))C

11,5

10

9

KM3-KSxxx-24A

PVC

MAT9020013

KM3-KSxxx-24A

PUR

MAT9020012

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

KGS2-KSxxx

TPE

MAT9021023

(4x(2x0,14)+(4x0,14)C+4x0,5)C

10,5

12

10

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

KGS2-KSxxx

TPE

MAT9021021

(2x(2x2x0,14)+(4x0,14)C+(4x0,5))C

11,5

10

11

KM3-KSxxx-24A

PUR

MAT9020011

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

KRY2-CDF-KSxxx

PVC

MAT9021034

(4x(2x0,25)+2x0,5)C

9,0

10

8

KRY2-CDF-KSxxx

PUR

MAT9021032

(4x(2x0,25)+2x0,5)C

9,5

10

9

KRY2-CDF-KSxxx

TPE

MAT9021031

(4x(2x0,25)+2x0,5)C

9,5

10

11

KRY2-KSxxx

PVC

MAT9021044

(4x(2x0,25)+2x0,5)C

9,0

10

8

Basic cable KM3-KSxxx-63A

PVC

MAT9020023

(4 G 10,0+2x(2x1,5)C)C

24,0

7,5

5

KRY2-KSxxx

PUR

MAT9021042

(4x(2x0,25)+2x0,5)C

9,5

10

9

KM3-KSxxx-63A

PUR

MAT9020022

(4 G 10,0+2x(2x1,5)C)C

22,0

10

6

KRY2-KSxxx

TPE

MAT9021041

(4x(2x0,25)+2x0,5)C

9,5

10

11

KM3-KSxxx-63A

PUR

MAT9020021

(4 G 10,0+2x(2x1,5)C)C

23,5

7,5

7

KGH2-KSxxx

PVC

MAT9023004

(4x(2x0,25)+2x1,0)C

9,5

10

8

Extension cable Extension cable KM3-KSxxx

PVC

MAT9022004

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

KGH2-KSxxx

TPE

MAT9023001

(4x(2x0,25)+2x1,0)C

9,5

10

11

KM3-KSxxx

PVC

MAT9022003

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

KGH3-KSxxx

PVC

MAT9023014

(4x(2x0,25)+2x1,0)C

9,5

10

8

KM3-KSxxx

PUR

MAT9022002

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

KGH3-KSxxx

TPE

MAT9023011

(4x(2x0,25)+2x1,0)C

9,5

10

11

KM3-KSxxx

PUR

MAT9022001

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

KGS2-KSxxx

PUR

MAT9023022

(2x(2x2x0,14)+(4x0,14)C+(4x0,5))C

11,5

10

9

KM3-KSxxx-24A

PVC

MAT9022014

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

KGS2-KSxxx

TPE

MAT9023023

(4x(2x0,14)+(4x0,14)C+4x0,5)C

10,5

12

10

KM3-KSxxx-24A

PVC

MAT9022013

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

KGS2-KSxxx

TPE

MAT9023021

(2x(2x2x0,14)+(4x0,14)C+(4x0,5))C

11,5

10

11

KM3-KSxxx-24A

PUR

MAT9022012

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

KRY2-CDF-KSxxx

PVC

MAT9023034

(4x(2x0,25)+2x0,5)C

9,0

10

8

KM3-KSxxx-24A

PUR

MAT9022011

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

KRY2-CDF-KSxxx

PUR

MAT9023032

(4x(2x0,25)+2x0,5)C

9,5

10

9

KRY2-CDF-KSxxx

TPE

MAT9023031

(4x(2x0,25)+2x0,5)C

9,5

10

11

KRY2-KSxxx

PVC

MAT9023044

(4x(2x0,25)+2x0,5)C

9,0

10

8

KRY2-KSxxx

PUR

MAT9023042

(4x(2x0,25)+2x0,5)C

9,5

10

9

KRY2-KSxxx

TPE

MAT9023041

(4x(2x0,25)+2x0,5)C

9,5

10

11

Extension cable KM3-KSxxx-63A

PVC

MAT9022023

(4 G 10,0+2x(2x1,5)C)C

24,0

7,5

5

KM3-KSxxx-63A

PUR

MAT9022022

(4 G 10,0+2x(2x1,5)C)C

KM3-KSxxx-63A

PUR

MAT9022021

(4 G 10,0+2x(2x1,5)C)C

22,0

10

6

23,5

7,5

7

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 418

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

419


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:14 Seite 420

NUM readycable® PVC/PUR/TPE

NUM harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

NUM harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to NUM standard (PVC-/TPE-Power cable) Jacket

Manufacturer

material

Part No.

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

26

NUM readycable® PVC/PUR/TPE

Page 334-337

Harnessed according to NUM standard (PVC-/PUR-Servo cable) Minimum

Page

bending

334

radius [x d]

to 337

Basic cable

Jacket

Manufacturer

material

Part No.

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

Extension cable

AGOFRU018LMxxx

PVC

MAT9280051

(4 G 1,5)C

10,5

7,5

1

AGOFRU020Mxxx

AGOFRU018LMxxx

TPE

MAT9282051

(4 G 1,5)C

9,5

7,5

2

AGOFRU020Mxxx

AGOFRU018LMxxx

TPE

MAT9961201

(4 G 1,5)C

9,5

7,5

3

AGOFRU019LMxxx

PVC

MAT9280052

(4 G 4,0)C

13,5

7,5

1

AGOFRU019LMxxx

TPE

MAT9282052

(4 G 4,0)C

13,5

7,5

2

AGOFRU019LMxxx

TPE

MAT9961202

(4 G 4,0)C

13,5

7,5

3

Extension cable

PVC

MAT9280013

(4 G 10,0+(2x1,5)C)C

22,5

7,5

5

PUR

MAT9282013

(4 G 10,0+(2x1,5)C)C

21,5

7,5

7

Harnessed according to NUM standard (PVC-/TPE-Encoder cable)

Basic cable AGOFRU029Mxxx

PVC

MAT9284001

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

9,0

10

8

AGOFRU029Mxxx

TPE

MAT9286001

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

10,5

10

11

Extension cable

AGOFRU018LMxxx

PVC

MAT9280061

(4 G 1,5)C

10,5

7,5

1

AGOFRU018LMxxx

TPE

MAT9282061

(4 G 1,5)C

9,5

7,5

2

AGOFRU018LMxxx

TPE

MAT9961203

(4 G 1,5)C

9,5

7,5

3

AGOFRU029Mxxx

PVC

MAT9284011

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

9,0

10

8

AGOFRU019LMxxx

PVC

MAT9280062

(4 G 4,0)C

13,5

7,5

1

AGOFRU029Mxxx

TPE

MAT9286011

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

10,5

10

11

AGOFRU030Mxxx

PVC

MAT9289001

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

9,0

10

8

AGOFRU030Mxxx

TPE

MAT9289004

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

10,5

10

11

AGOFRU019LMxxx

TPE

MAT9282062

(4 G 4,0)C

13,5

7,5

2

AGOFRU019LMxxx

TPE

MAT9961204

(4 G 4,0)C

13,5

7,5

3

Basic cable

Harnessed according to NUM standard (PVC-/PUR-Servo cable)

Basic cable

Extension cable

AGOFRU018Mxxx

PVC

MAT9280001

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

AGOFRU018Mxxx

PUR

MAT9282001

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

AGOFRU019Mxxx

PVC

MAT9280002

(4 G 4,0+(2x1,5)C)C

15,5

7,5

5

AGOFRU030Mxxx

PVC

MAT9289011

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

9,0

10

8

AGOFRU019Mxxx

PUR

MAT9282002

(4 G 4,0+(2x1,5)C)C

16,0

7,5

7

AGOFRU030Mxxx

TPE

MAT9289014

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

10,5

10

11

Harnessed according to NUM standard (PVC-/TPE-Fan cable)

Basic cable Basic cable AGOFRU020Mxxx

PVC

MAT9280003

(4 G 10,0+(2x1,5)C)C

22,5

7,5

5

AGOFRU020Mxxx

PUR

MAT9282003

(4 G 10,0+(2x1,5)C)C

21,5

7,5

7

AGOFRU012Mxxx

PVC

MAT9289005

4 G 1,0

7,5

10

17

AGOFRU012Mxxx

TPE

MAT9289007

4 G 1,0

6,5

5

24

Extension cable Extension cable AGOFRU018Mxxx

PVC

MAT9280011

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

AGOFRU018Mxxx

PUR

MAT9282011

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

AGOFRU012Mxxx

PVC

MAT9289015

4 G 1,0

7,5

10

17

AGOFRU019Mxxx

PVC

MAT9280012

(4 G 4,0+(2x1,5)C)C

15,5

7,5

5

AGOFRU012Mxxx

TPE

MAT9289017

4 G 1,0

6,5

5

24

AGOFRU019Mxxx

PUR

MAT9282012

(4 G 4,0+(2x1,5)C)C

16,0

7,5

7

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 420

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

421


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:15 Seite 422

Omron readycable® PVC/PUR/TPE

Omron harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

Omron harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Omron standard (PVC-/TPE-Power cable) Manufacturer

Jacket material

Part No.

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Page 334-337

Harnessed according to Omron standard (PVC-/PUR-/TPE-Encoder cable) Minimum

Page

bending

334

radius [x d]

to 337

Basic cable R88A-CAWA-xxxS-DE

26

Omron readycable® PVC/PUR/TPE

Manufacturer

Jacket material

Part No.

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

8

Basic cable TPE

MAT9810004

(4 G 0,5)C

8,0

7,5 x d

2

JZSP-CHP800-xx-E

PVC

MAT9710009

(4x(2x0,25)+2x0,5)C

9,0

10

R88A-CAWA-xxxS-DE

TPE

MAT9962104

R88A-CAWCxxx

PVC

MAT9710005

(4 G 0,5)C

8,0

7,5 x d

3

JZSP-CHP800-xx-E

PUR

MAT9842103

(4x(2x0,25)+2x0,5)C

9,5

10

9

(4 G 1,5)C

10,5

7,5 x d

1

JZSP-CHP800-xx-E

TPE

MAT9810009

(4x(2x0,25)+2x0,5)c

9,5

10

11

R88A-CAWCxxx

TPE

R88A-CAWCxxx

TPE

MAT9810005

(4 G 1,5)C

9,5

7,5 x d

2

MAT9962105

(4 G 1,5)C

9,5

7,5 x d

3

R88A-CAWCxxxS-E

PVC

R88A-CAWCxxxS-E

TPE

MAT9710003

(4 G 1,5)C

10,5

7,5 x d

1

MAT9810003

(4 G 1,5)C

9,5

7,5 x d

2

JZSP-CSP21-XX-E-G1

PVC

MAT9710011* (3x(2x0,25))C

7,0

10

14

R88A-CAWCxxxS-E

TPE

MAT9962103

R88A-CAWDxxxS

PVC

MAT9710006

(4 G 1,5)C

9,5

7,5 x d

3

JZSP-CSP21-XX-E-G1

PUR

MAT9842105

(3x(2x0,25))C

8,0

10

9

(4 G 2,5)C

12,0

7,5 x d

1

JZSP-CSP21-XX-E-G1

TPE

MAT9810011

(3 x (2 x 0,25))C

7,5

10

11

R88A-CAWDxxxS

TPE

R88A-CAWDxxxS

TPE

MAT9810006

(4 G 2,5)C

11,5

7,5 x d

2

MAT9962106

(4 G 2,5)C

11,5

7,5 x d

3

R88A-CAWDxxxS-E

PVC

MAT9710001

(4 G 2,5)C

R88A-CAWDxxxS-E

TPE

MAT9810001

(4 G 2,5)C

12,0

7,5 x d

1

11,5

7,5 x d

2

R88A-CRWA-xxxC-DE

PVC

MAT9710012

(2x(2x0,25)+2x0,5)C

7,0

10

8

R88A-CAWDxxxS-E

TPE

MAT9962101

(4 G 2,5)C

R88A-CAWFxxxS-E

PVC

MAT9710002

(4 G 4,0)C

11,5

7,5 x d

3

R88A-CRWA-xxxC-DE

PUR

MAT9842106

(2x(2x0,25)+2x0,5)C

9,0

10

9

13,5

7,5 x d

1

R88A-CRWA-xxxC-DE

TPE

MAT9810012

(2x(2x0,25)+2x0,5)C

7,0

10

11

R88A-CAWFxxxS-E

TPE

MAT9810002

R88A-CAWFxxxS-E

TPE

MAT9962102

(4 G 4,0)C

13,5

7,5 x d

2

(4 G 4,0)C

13,5

7,5 x d

3

Basic cable

Basic cable

Harnessed according to Omron standard (PVC-/PUR-/TPE-Control cable)

Basic cable

Harnessed according to Omron standard (PVC-/PUR-/TPE-Encoder cable)

Basic cable

JZSP-CHM000-xx-E

PVC

MAT9712103

(5 G 0,5)C

9,0

7,5-15

18

JZSP-CHM000-xx-E

PVC

MAT9710015

(5 G 0,5)C

8,5

6,8-7,5

20

R88A-CRWBxxxN-E

PVC

MAT9710007

(4x(2x0,25)+2x1,0)C

9,5

10

8

JZSP-CHM000-xx-E

PUR

MAT9810015

(5 G 0,5)C

8,5

6,8-7,5

23

R88A-CRWBxxxN-E

PUR

MAT9842101

(4x(2x0,25)+2x1,0)C

9,5

10

9

JZSP-CHM000-xx-E

TPE

MAT9912103

(5 x 0,5)C

7,5

5

25

R88A-CRWBxxxN-E

TPE

MAT9810007

(4x(2x0,25)+2x1,0)C

9,5

10

11

JZSP-CHM030-xx-E

PVC

MAT9712105

(7 G 0,75)C

10,5

7,5-15

18

R88A-CRWBxxxN

PVC

MAT9710010

(4x(2x0,25)+2x1,0)C

9,5

10

8

JZSP-CHM030-xx-E

PVC

MAT9710017

(7 G 0,5)C

10,0

6,8-7,5

20

R88A-CRWBxxxN

PUR

MAT9842104

(4x(2x0,25)+2x1,0)C

9,5

10

9

JZSP-CHM030-xx-E

PUR

MAT9810017

(7 G 0,5)C

9,5

6,8-7,5

23

R88A-CRWBxxxN

TPE

MAT9810010

(4x(2x0,25)+2x1,0)C

9,5

10

11

JZSP-CHM030-xx-E

TPE

MAT9912105

(7 x 0,5)C

8,5

5

25

JZSP-CHP800-xx-ME

PVC

MAT9710008

(4x(2x0,25)+2x0,5)C

9,0

10

8

JZSP-CHP800-xx-ME

PUR

MAT9842102

(4x(2x0,25)+2x0,5)C

9,5

10

9

JZSP-CHP800-xx-ME

TPE

MAT9810008

(4x(2x0,25)+2x0,5)c

9,5

10

11

Basic cable

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 422

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. * Nominal voltage: 300/300 V igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

423


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:15 Seite 424

Omron readycable® PVC/PUR/TPE

Omron harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

Rexroth harnessed drive cables ... optionally with PVC-/PUR-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Omron standard (PVC-/PUR-/TPE-Control cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Page 334-337

Harnessed according to Rexroth standard (PVC-/PUR-Power cable)

Minimum

Page

bending

334

radius [x d]

to 337

Basic cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

7,5

5

Basic cable

JZSP-CHM000-xx-ME

PVC

MAT9712104

(5 G 0,5)C

JZSP-CHM000-xx-ME

PVC

MAT9710016

(5 G 0,5)C

JZSP-CHM000-xx-ME

PUR

MAT9810016

(5 G 0,5)C

JZSP-CHM000-xx-ME

TPE

MAT9912104

(5 x 0,5)C

JZSP-CHM030-xx-ME

PVC

MAT9712106

(7 G 0,75)C

JZSP-CHM030-xx-ME

PVC

MAT9710018

(7 G 0,5)C

JZSP-CHM030-xx-ME

PUR

MAT9810018

(7 G 0,5)C

JZSP-CHM030-xx-ME

TPE

MAT9912106

(7 x 0,5)C

9,0

7,5-15

18

IKL0001

PVC

MAT9190022

(4 G 1,0+2x(2x0,75)C)C

13,5

8,5

6,8-7,5

20

IKL0001

PUR

MAT9851301

(4 G 1,0+2x(2x0,75)C)C

13,0

10

6

8,5

6,8-7,5

23

IKL0001

PUR

MAT9090022

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

7

7,5

5

25

IKL0006

PVC

MAT9190067

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

5

10,5

7,5-15

18

IKL0006

PUR

MAT9851302

(4 G 1,0+2x(2x0,75)C)C

13,0

10

6

10,0

6,8-7,5

20

IKL0006

PUR

MAT9090067

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

7

9,5

6,8-7,5

23

IKL0011

PVC

MAT9190023

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

5

8,5

5

25

IKL0011

PUR

MAT9851303

(4 G 1,0+2x(2x0,75)C)C

13,0

10

6

IKL0011

PUR

MAT9090023

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

7

IKL0021

PVC

MAT9751301

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

IKL0021

PVC

MAT9190024

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

Basic cable JZSP-CSM22-xx-E-G1

PVC

MAT9712102

(4 G 0,75)C

9,0

7,5-15

18

IKL0021

PUR

MAT9851304

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

JZSP-CSM22-xx-E-G1

PVC

MAT9710014

(4 G 0,75)C

8,5

6,8-7,5

20

IKL0021

PUR

MAT9090024

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

JZSP-CSM22-xx-E-G1

PUR

MAT9810014

(4 G 0,75)C

8,5

6,8-7,5

23

IKL0041

PVC

MAT9751302

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

JZSP-CSM22-xx-E-G1

TPE

MAT9912102

(4 G 0,75)C

7,5

5

25

IKL0041

PVC

MAT9190017

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

IKL0041

PUR

MAT9851305

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

IKL0041

PUR

MAT9090017

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

Basic cable MAT9712107

(3 G 0,5)C

IKL0042

PVC

MAT9751303

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

7,5-15

18

IKL0042

PVC

MAT9190077

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

7,0

6,8-7,5

20

IKL0042

PUR

MAT9851306

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

8,0

6,8-7,5

23

IKL0042

PUR

MAT9090077

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

5

25

IKL0061

PVC

MAT9751304

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

IKL0061

PVC

MAT9190018

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

IKL0061

PUR

MAT9851307

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

IKL0061

PUR

MAT9090018

(4 G 4,0+2x(2x1,5)C)C

18,0

7,5

7

R88A-CAWExxxB

PVC

8,0

R88A-CAWExxxB

PVC

MAT9710019

(2 x 0,5)C

R88A-CAWExxxB

PUR

MAT9810019

(4 G 0,5)C

R88A-CAWExxxB

TPE

MAT9912107

(4 x 0,5)C

7,0

Basic cable R88A-CAWCxxxB-E

PVC

MAT9712101

2 x 0,5

5,5

5

17

IKL0081

PVC

MAT9751305

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

R88A-CAWCxxxB-E

PVC

MAT9710013

2 x 0,5

6,0

6,8-7,5

19

IKL0081

PVC

MAT9190030

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

R88A-CAWCxxxB-E

PUR

MAT9810013

3 G 0,75

6,5

6,8-7,5

22

IKL0081

PUR

MAT9851308

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

R88A-CAWCxxxB-E

TPE

MAT9912101

2 x 0,5

5,0

5

24

IKL0081

PUR

MAT9090030

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

IKL0101

PVC

MAT9751306

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

IKL0101

PVC

MAT9190025

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

IKL0101

PUR

MAT9851309

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

IKL0101

PUR

MAT9090025

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

IKL0121

PVC

MAT9190019

(4 G 10,0+2x(2x1,5)C)C

24,0

7,5

5

IKL0121

PUR

MAT9851310

(4 G 10,0+2x(2x1,5)C)C

22,0

10

6

IKL0121

PUR

MAT9090019

(4 G 10,0+2x(2x1,5)C)C

23,5

7,5

7

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 424

26

Rexroth readycable® PVC/PUR

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

425


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:15 Seite 426

Rexroth readycable® PVC/PUR

Rexroth harnessed drive cables ... optionally with PVC-/PUR-jacket

Rexroth harnessed drive cables ... optionally with PVC-/PUR-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Rexroth standard (PVC-/PUR-Power cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Page 334-337

Harnessed according to Rexroth standard (PVC-/PUR-Power cable) Minimum

Page

bending

334

radius [x d]

to 337

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

IKL0161

PVC

MAT9190063

(4 G 25,0+2x(2x1,5)C)C

31,0

7,5

5

IKG4087

PVC

MAT9751314

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

IKL0161

PUR

MAT9851311

(4 G 25,0+2x(2x1,5)C)C

28,0

10

6

IKG4087

PVC

MAT9190009

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

IKL0161

PUR

MAT9090063

(4 G 25,0+2x(2x1,5)C)C

31,0

7,5

7

IKG4087

PUR

MAT9851325

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

IKG0331

PVC

MAT9190014

(4 G 0,75+(2x0,5)C)C

11,5

7,5

5

IKG4087

PUR

MAT9090009

(4 G 4,0+2x(2x1,5)C)C

18,0

7,5

7

IKG0331

PUR

MAT9090014

(4 G 0,75+(2x0,5)C)C

11,5

7,5

7

IKG4090

PVC

MAT9751315

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

IKG4008

PVC

MAT9190064

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

5

IKG4090

PVC

MAT9190010

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

IKG4008

PUR

MAT9851315

(4 G 1,0+2x(2x0,75)C)C

13,0

10

6

IKG4090

PUR

MAT9851326

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

IKG4008

PUR

MAT9090064

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

7

IKG4090

PUR

MAT9090010

(4 G 4,0+2x(2x1,5)C)C

18,0

7,5

7

IKG4009

PVC

MAT9190001

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

5

IKG4100

PVC

MAT9190020

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

5

IKG4009

PUR

MAT9851316

(4 G 1,0+2x(2x0,75)C)C

13,0

10

6

IKG4100

PUR

MAT9851327

(4 G 1,0+2x(2x0,75)C)C

13,0

10

6

IKG4009

PUR

MAT9090001

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

7

IKG4100

PUR

MAT9090020

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

7

IKG4017

PVC

MAT9190002

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

5

IKG4103

PVC

MAT9751316

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

IKG4017

PUR

MAT9851317

(4 G 1,0+2x(2x0,75)C)C

13,0

10

6

IKG4103

PVC

MAT9190076

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

IKG4017

PUR

MAT9090002

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

7

IKG4103

PUR

MAT9851328

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

IKG4018

PVC

MAT9190003

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

5

IKG4103

PUR

MAT9090076

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

IKG4018

PUR

MAT9851318

(4 G 1,0+2x(2x0,75)C)C

13,0

10

6

IKG4107

PVC

MAT9751317

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

IKG4018

PUR

MAT9090003

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

7

IKG4107

PVC

MAT9190011

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

IKG4020

PVC

MAT9190004

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

5

IKG4107

PUR

MAT9851329

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

IKG4020

PUR

MAT9851319

(4 G 1,0+2x(2x0,75)C)C

13,0

10

6

IKG4107

PUR

MAT9090011

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

IKG4020

PUR

MAT9090004

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

7

IKG4118

PVC

MAT9751318

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

IKG4055

PVC

MAT9751309

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

IKG4118

PVC

MAT9190070

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

IKG4055

PVC

MAT9190005

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

IKG4118

PUR

MAT9851330

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

IKG4055

PUR

MAT9851320

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

IKG4118

PUR

MAT9090070

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

IKG4055

PUR

MAT9090005

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

IKG4119

PVC

MAT9190027

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

5

IKG4060

PVC

MAT9751310

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

IKG4119

PUR

MAT9851331

(4 G 1,0+2x(2x0,75)C)C

13,0

10

6

IKG4060

PVC

MAT9190006

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

IKG4119

PUR

MAT9090027

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

7

IKG4060

PUR

MAT9851321

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

IKG4147

PVC

MAT9751319

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

IKG4060

PUR

MAT9090006

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

IKG4147

PVC

MAT9190038

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

IKG4067

PVC

MAT9751311

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

IKG4147

PUR

MAT9851332

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

IKG4067

PVC

MAT9190007

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

IKG4147

PUR

MAT9090038

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

IKG4067

PUR

MAT9851322

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

IKG4150

PVC

MAT9751320

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

IKG4067

PUR

MAT9090007

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

IKG4150

PVC

MAT9190012

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

IKG4070

PVC

MAT9751312

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

IKG4150

PUR

MAT9851333

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

IKG4070

PVC

MAT9190008

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

IKG4150

PUR

MAT9090012

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

IKG4070

PUR

MAT9851323

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

IKG4155

PVC

MAT9751321

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

IKG4070

PUR

MAT9090008

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

IKG4155

PVC

MAT9190028

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

IKG4072

PVC

MAT9751313

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

IKG4155

PUR

MAT9851334

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

IKG4072

PVC

MAT9190068

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

IKG4155

PUR

MAT9090028

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

IKG4072

PUR

MAT9851324

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

IKG4072

PUR

MAT9090068

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 426

26

Rexroth readycable® PVC/PUR

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

427


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:15 Seite 428

Rexroth readycable® PVC/PUR

Rexroth harnessed drive cables ... optionally with PVC-/PUR-jacket

Rexroth harnessed drive cables ... optionally with PVC-/PUR-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Rexroth standard (PVC-/PUR-Power cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Page 334-337

Harnessed according to Rexroth standard (PVC-/PUR-Power cable) Minimum

Page

bending

334

radius [x d]

to 337

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

IKG4164

PVC

MAT9190035

(4 G 10,0+2x(2x1,5)C)C

24,0

7,5

5

IKG4016

PVC

MAT9191002

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

5

IKG4164

PUR

MAT9851335

(4 G 10,0+2x(2x1,5)C)C

22,0

10

6

IKG4016

PUR

MAT9851343

(4 G 1,0+2x(2x0,75)C)C

13,0

10

6

IKG4164

PUR

MAT9090035

(4 G 10,0+2x(2x1,5)C)C

23,5

7,5

7

IKG4016

PUR

MAT9091002

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

7

IKG4167

PVC

MAT9190013

(4 G 10,0+2x(2x1,5)C)C

24,0

7,5

5

IKG4061

PVC

MAT9751322

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

IKG4167

PUR

MAT9851336

(4 G 10,0+2x(2x1,5)C)C

22,0

10

6

IKG4061

PVC

MAT9191004

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

IKG4167

PUR

MAT9090013

(4 G 10,0+2x(2x1,5)C)C

23,5

7,5

7

IKG4061

PUR

MAT9851344

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

IKG4172

PVC

MAT9190069

(4 G 16,0+2x(2x1,5)C)C

27,0

7,5

5

IKG4061

PUR

MAT9091004

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

IKG4172

PUR

MAT9851337

(4 G 16,0+2x(2x1,5)C)C

26,0

10

6

IKG4074

PVC

MAT9751323

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

IKG4172

PUR

MAT9090069

(4 G 16,0+2x(2x1,5)C)C

26,0

7,5

7

IKG4074

PVC

MAT9191014

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

IKG4173

PVC

MAT9190072

(4 G 25,0+2x(2x1,5)C)C

31,0

7,5

5

IKG4074

PUR

MAT9851345

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

IKG4173

PUR

MAT9851338

(4 G 25,0+2x(2x1,5)C)C

28,0

10

6

IKG4074

PUR

MAT9091014

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

IKG4173

PUR

MAT9090072

(4 G 25,0+2x(2x1,5)C)C

31,0

7,5

7

IKG4081

PVC

MAT9751324

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

IKG4186

PVC

MAT9190021

(4 G 16,0+2x(2x1,5)C)C

27,0

7,5

5

IKG4081

PVC

MAT9191016

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

IKG4186

PUR

MAT9851339

(4 G 16,0+2x(2x1,5)C)C

26,0

10

6

IKG4081

PUR

MAT9851346

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

IKG4186

PUR

MAT9090021

(4 G 16,0+2x(2x1,5)C)C

26,0

7,5

7

IKG4081

PUR

MAT9091016

(4 G 4,0+2x(2x1,5)C)C

18,0

7,5

7

IKG4200

PVC

MAT9190032

(4 G 16,0+2x(2x1,5)C)C

27,0

7,5

5

IKG4141

PVC

MAT9751325

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

IKG4200

PUR

MAT9851340

(4 G 16,0+2x(2x1,5)C)C

26,0

10

6

IKG4141

PVC

MAT9191003

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

IKG4200

PUR

MAT9090032

(4 G 16,0+2x(2x1,5)C)C

26,0

7,5

7

IKG4141

PUR

MAT9851347

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

IKG4204

PVC

MAT9190052

(4 G 25,0+2x(2x1,5)C)C

31,0

7,5

5

IKG4141

PUR

MAT9091003

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

IKG4204

PUR

MAT9851341

(4 G 25,0+2x(2x1,5)C)C

28,0

10

6

IKG4161

PVC

MAT9190036

(4 G 10,0+2x(2x1,5)C)C

24,0

7,5

5

IKG4204

PUR

MAT9090052

(4 G 25,0+2x(2x1,5)C)C

31,0

7,5

7

IKG4161

PUR

MAT9851348

(4 G 10,0+2x(2x1,5)C)C

22,0

10

6

IKG4161

PUR

MAT9090036

(4 G 10,0+2x(2x1,5)C)C

23,5

7,5

7

MAT9751326

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

Connecting cable with adapter plugs

Basic cable

IKL0023

PVC

MAT9751307

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

IKL0023

PVC

MAT9191013

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

RKL4300

PVC

IKL0023

PUR

MAT9851312

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

RKL4300

PVC

MAT9190071

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

IKL0023

PUR

MAT9091013

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

RKL4300

PUR

MAT9851349

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

IKL0089

PVC

MAT9751308

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

RKL4300

PUR

MAT9090071

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

IKL0089

PUR

MAT9191005

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

RKL4301

PVC

MAT9751327

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

IKL0089

PUR

MAT9851313

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

RKL4301

PVC

MAT9190037

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

IKL0089

PUR

MAT9091005

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

RKL4301

PUR

MAT9851350

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

IKL0168

PVC

MAT9191006

(4 G 25,0+2x(2x1,5)C)C

31,0

7,5

5

RKL4301

PUR

MAT9090037

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

IKL0168

PUR

MAT9851314

(4 G 25,0+2x(2x1,5)C)C

28,0

10

6

RKL4302

PVC

MAT9190026

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

5

IKL0168

PUR

MAT9091006

(4 G 25,0+2x(2x1,5)C)C

31,0

7,5

7

RKL4302

PUR

MAT9851351

(4 G 1,0+2x(2x0,75)C)C

13,0

10

6

IKG0332

PVC

MAT9190015

(4 G 0,75+(2x0,5)C)C

11,5

7,5

5

RKL4302

PUR

MAT9090026

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

7

IKG0332

PUR

MAT9090015

(4 G 0,75+(2x0,5)C)C

11,5

7,5

7

RKL4303

PVC

MAT9190029

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

5

IKG4006

PVC

MAT9191001

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

5

RKL4303

PUR

MAT9851352

(4 G 1,0+2x(2x0,75)C)C

13,0

10

6

IKG4006

PUR

MAT9851342

(4 G 1,0+2x(2x0,75)C)C

13,0

10

6

RKL4303

PUR

MAT9090029

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

7

IKG4006

PUR

MAT9091001

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

7

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 428

26

Rexroth readycable® PVC/PUR

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

429


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:15 Seite 430

Rexroth readycable® PVC/PUR

Rexroth harnessed drive cables ... optionally with PVC-/PUR-jacket

Rexroth harnessed drive cables ... optionally with PVC-/PUR-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Rexroth standard (PVC-/PUR-Power cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Page 334-337

Harnessed according to Rexroth standard (PVC-/PUR-Power cable) Minimum

Page

bending

334

radius [x d]

to 337

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

RKL4306

PVC

MAT9751328

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

RKL4320

PVC

MAT9751338

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

RKL4306

PVC

MAT9190040

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

RKL4320

PVC

MAT9190039

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

RKL4306

PUR

MAT9851353

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

RKL4320

PUR

MAT9851363

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

RKL4306

PUR

MAT9090040

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

RKL4320

PUR

MAT9090039

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

RKL4307

PVC

MAT9751329

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

RKL4321

PVC

MAT9751339

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

RKL4307

PVC

MAT9190041

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

RKL4321

PVC

MAT9190075

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

RKL4307

PUR

MAT9851354

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

RKL4321

PUR

MAT9851364

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

RKL4307

PUR

MAT9090041

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

RKL4321

PUR

MAT9090075

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

RKL4308

PVC

MAT9751330

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

RKL4322

PVC

MAT9751340

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

RKL4308

PVC

MAT9190033

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

RKL4322

PVC

MAT9190078

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

RKL4308

PUR

MAT9851355

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

RKL4322

PUR

MAT9851365

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

RKL4308

PUR

MAT9090033

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

RKL4322

PUR

MAT9090078

(4 G 4,0+2x(2x1,5)C)C

18,0

7,5

7

RKL4309

PVC

MAT9751331

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

RKL4323

PVC

MAT9751341

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

RKL4309

PVC

MAT9190042

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

RKL4323

PVC

MAT9190073

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

RKL4309

PUR

MAT9851356

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

RKL4323

PUR

MAT9851366

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

RKL4309

PUR

MAT9090042

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

RKL4323

PUR

MAT9090073

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

RKL4310

PVC

MAT9751332

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

RKL4324

PVC

MAT9190079

(4 G 10,0+2x(2x1,5)C)C

24,0

7,5

5

RKL4310

PVC

MAT9190043

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

RKL4324

PUR

MAT9851367

(4 G 10,0+2x(2x1,5)C)C

22,0

10

6

RKL4310

PUR

MAT9851357

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

RKL4324

PUR

MAT9090079

(4 G 10,0+2x(2x1,5)C)C

23,5

7,5

7

RKL4310

PUR

MAT9090043

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

RKL4325

PVC

MAT9751342

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

RKL4313

PVC

MAT9751333

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

RKL4325

PVC

MAT9190049

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

RKL4313

PVC

MAT9190062

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

RKL4325

PUR

MAT9851368

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

RKL4313

PUR

MAT9851358

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

RKL4325

PUR

MAT9090049

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

RKL4313

PUR

MAT9090062

(4 G 4,0+2x(2x1,5)C)C

18,0

7,5

7

RKL4326

PVC

MAT9751343

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

RKL4314

PVC

MAT9751334

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

RKL4326

PVC

MAT9190045

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

RKL4314

PVC

MAT9190060

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

RKL4326

PUR

MAT9851369

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

RKL4314

PUR

MAT9851359

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

RKL4326

PUR

MAT9090045

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

RKL4314

PUR

MAT9090060

(4 G 4,0+2x(2x1,5)C)C

18,0

7,5

7

RKL4327

PVC

MAT9751344

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

RKL4315

PVC

MAT9751335

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

RKL4327

PVC

MAT9190050

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

RKL4315

PVC

MAT9190059

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

RKL4327

PUR

MAT9851370

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

RKL4315

PUR

MAT9851360

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

RKL4327

PUR

MAT9090050

(4 G 4,0+2x(2x1,5)C)C

18,0

7,5

7

RKL4315

PUR

MAT9090059

(4 G 4,0+2x(2x1,5)C)C

18,0

7,5

7

RKL4328

PVC

MAT9751345

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

RKL4317

PVC

MAT9751336

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

RKL4328

PVC

MAT9190057

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

RKL4317

PVC

MAT9190061

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

RKL4328

PUR

MAT9851371

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

RKL4317

PUR

MAT9851361

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

RKL4328

PUR

MAT9090057

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

RKL4317

PUR

MAT9090061

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

RKL4329

PVC

MAT9190051

(4 G 10,0+2x(2x1,5)C)C

24,0

7,5

5

RKL4318

PVC

MAT9751337

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

RKL4329

PUR

MAT9851372

(4 G 10,0+2x(2x1,5)C)C

22,0

10

6

RKL4318

PVC

MAT9190047

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

RKL4329

PUR

MAT9090051

(4 G 10,0+2x(2x1,5)C)C

23,5

7,5

7

RKL4318

PUR

MAT9851362

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

RKL4318

PUR

MAT9090047

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 430

26

Rexroth readycable® PVC/PUR

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

431


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:15 Seite 432

Rexroth readycable® PVC/PUR

Rexroth harnessed drive cables ... optionally with PVC-/PUR-jacket

Rexroth harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Rexroth standard (PVC-/PUR-Power cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Page 334-337

Harnessed according to Rexroth standard (PVC-/PUR-Power cable) Minimum

Page

bending

334

radius [x d]

to 337

Manufacturer

Jacket material

Part No.

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

RKL4330

PVC

MAT9190080

(4 G 16,0+2x(2x1,5)C)C

27,0

7,5

5

RKL4340

PVC

MAT9191015

(4 G 16,0+2x(2x1,5)C)C

27,0

7,5

5

RKL4330

PUR

MAT9851373

(4 G 16,0+2x(2x1,5)C)C

26,0

10

6

RKL4340

PUR

MAT9851383

(4 G 16,0+2x(2x1,5)C)C

26,0

10

6

RKL4330

PUR

MAT9090080

(4 G 16,0+2x(2x1,5)C)C

26,0

7,5

7

RKL4340

PUR

MAT9091015

(4 G 16,0+2x(2x1,5)C)C

26,0

7,5

7

RKL4331

PVC

MAT9190081

(4 G 25,0+2x(2x1,5)C)C

31,0

7,5

5

RKL4331

PUR

MAT9851374

(4 G 25,0+2x(2x1,5)C)C

28,0

10

6

RKL4331

PUR

MAT9090081

(4 G 25,0+2x(2x1,5)C)C

31,0

7,5

7

Connecting cable with adapter plugs

Harnessed according to Rexroth standard (PVC-/PUR-/TPE-Encoder cable)

Basic cable IKS0230

PVC

MAT9110008

(2x(2x0,25)+2x0,5)C

7,0

10

8

IKS0230

PUR

MAT9841307

(2x(2x0,25)+2x0,5)C

9,0

10

9

13,5

10

4

IKS0230

TPE

MAT9100008

(2x(2x0,25)+2x0,5)C

7,0

10

11

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

IKS0251

TPE

MAT9100014

(12x0,5)C

11,5

10

25

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

IKS0253

TPE

MAT9100023

(12x0,5)C

11,5

10

25

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

IKS0259

TPE

MAT9100032

(12x0,5)C

11,5

10

25

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

5

IKS0262

TPE

MAT9100016

(12x0,5)C

11,5

10

25

MAT9851376

(4 G 1,0+2x(2x0,75)C)C

13,0

10

6

IKS0301

PVC

MAT9110015

(4x(2x0,25)+2x1,0)C

9,5

10

8

MAT9091008

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

7

IKS0301

PUR

MAT9841308

(4x(2x0,25)+2x1,0)C

9,5

10

9

PVC

MAT9751347

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

IKS0301

TPE

MAT9100015

(4x(2x0,25)+2x1,0)C

9,5

10

11

PVC

MAT9191009

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

IKS0315

PVC

MAT9110020

(4x(2x0,25)+2x1,0)C

9,5

10

8

RKL4311

PUR

MAT9851377

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

IKS0315

PUR

MAT9841309

(4x(2x0,25)+2x1,0)C

9,5

10

9

RKL4311

PUR

MAT9091009

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

IKS0315

TPE

MAT9100020

(4x(2x0,25)+2x1,0)C

9,5

10

11

RKL4312

PVC

MAT9751348

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

IKS0374

PVC

MAT9110011

(4x(2x0,25)+2x1,0)C

9,5

10

8

RKL4312

PVC

MAT9191010

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

IKS0374

PUR

MAT9841310

(4x(2x0,25)+2x1,0)C

9,5

10

9

RKL4312

PUR

MAT9851378

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

IKS0374

TPE

MAT9100011

(4x(2x0,25)+2x1,0)C

9,5

10

11

RKL4312

PUR

MAT9091010

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

IKS4001

PVC

MAT9110026

(4x(2x0,14)+4x1,0+(4x0,14)C)C

9,0

10

8

RKL4316

PVC

MAT9751349

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

IKS4001

PUR

MAT9841311

(4x(2x0,14)+(4x0,14)C+4x1,0)C

11,5

10

9

RKL4316

PVC

MAT9191011

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

IKS4001

TPE

MAT9100026

(4x(2x0,14)+(4x0,14)C+4x1,0)C

11,5

10

11

RKL4316

PUR

MAT9851379

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

IKS4002

PVC

MAT9110010

(3x0,25+3x(2x0,25)C+2x1,0)C

9,0

10

8

RKL4316

PUR

MAT9091011

(4 G 4,0+2x(2x1,5)C)C

18,0

7,5

7

IKS4002

PUR

MAT9841312

(3x(2x0,25)C+(3x0,25)+2x1,0)C

11,5

10

9

RKL4319

PVC

MAT9751350

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

IKS4002

TPE

MAT9100010

(3x(2x0,25)C+(3x0,25)+2x1,0)C

11,5

10

11

RKL4319

PVC

MAT9191012

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

IKS4020

PVC

MAT9110006

(4x(2x0,14)+4x1,0+(4x0,14)C)C

9,0

10

8

RKL4319

PUR

MAT9851380

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

IKS4020

PUR

MAT9841313

(4x(2x0,14)+(4x0,14)C+4x1,0)C

11,5

10

9

RKL4319

PUR

MAT9091012

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

IKS4020

TPE

MAT9100006

(4x(2x0,14)+(4x0,14)C+4x1,0)C

11,5

10

11

RKL4336

PVC

MAT9751351

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

IKS4038

PVC

MAT9110027

(4x(2x0,14)+4x1,0+(4x0,14)C)C

9,0

10

8

RKL4336

PVC

MAT9191018

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

IKS4038

PUR

MAT9841314

(4x(2x0,14)+(4x0,14)C+4x1,0)C

11,5

10

9

RKL4336

PUR

MAT9851381

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

IKS4038

TPE

MAT9100027

(4x(2x0,14)+(4x0,14)C+4x1,0)C

11,5

10

11

RKL4336

PUR

MAT9091018

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

IKS4041

PVC

MAT9110028

(3x0,25+3x(2x0,25)C+2x1,0)C

9,0

10

8

RKL4338

PVC

MAT9751352

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

IKS4041

PUR

MAT9841315

(3x(2x0,25)C+(3x0,25)+2x1,0)C

11,5

10

9

RKL4338

PVC

MAT9191017

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

IKS4041

TPE

MAT9100028

(3x(2x0,25)C+(3x0,25)+2x1,0)C

11,5

10

11

RKL4338

PUR

MAT9851382

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

RKL4338

PUR

MAT9091017

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

RKL4304

PVC

MAT9751346

RKL4304

PVC

MAT9191007

RKL4304

PUR

MAT9851375

RKL4304

PUR

MAT9091007

RKL4305

PVC

MAT9191008

RKL4305

PUR

RKL4305

PUR

RKL4311 RKL4311

(4 G 1,5+2x(2x0,75)C)C

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 432

26

Rexroth readycable® PVC/PUR/TPE

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

433


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:15 Seite 434

Rexroth readycable® PVC/PUR/TPE

Rexroth harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

Rexroth harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Rexroth standard (PVC-/PUR-/TPE-Encoder cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page 334-337

Harnessed according to Rexroth standard (PVC-/PUR-/TPE-Encoder cable) Page

bending

334

radius [x d]

to 337

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

IKS4042

PVC

MAT9110017

(4x(2x0,25)+2x0,5)C

9,0

10

8

IKS4151

PVC

MAT9111002

(4x(2x0,25)+2x0,5)C

9,0

10

8

IKS4042

PUR

MAT9841316

(4x(2x0,25)+2x0,5)C

9,5

10

9

IKS4151

PUR

MAT9841328

(4x(2x0,25)+2x0,5)C

9,5

10

9

IKS4042

TPE

MAT9100017

(4x(2x0,25)+2x0,5)C

9,5

10

11

IKS4151

TPE

MAT9101002

(4x(2x0,25)+2x0,5)C

9,5

10

11

IKS4066

PVC

MAT9110025

(4x(2x0,25)+2x0,5)C

9,0

10

8

IKS4153

PVC

MAT9111003

(4x(2x0,25)+2x0,5)C

9,0

10

8

IKS4066

PUR

MAT9841317

(4x(2x0,25)+2x0,5)C

9,5

10

9

IKS4153

PUR

MAT9841329

(4x(2x0,25)+2x0,5)C

9,5

10

9

IKS4066

TPE

MAT9100025

(4x(2x0,25)+2x0,5)C

9,5

10

11

IKS4153

TPE

MAT9101003

(4x(2x0,25)+2x0,5)C

9,5

10

11

IKS4103

PVC

MAT9110001

(4x(2x0,25)+2x0,5)C

9,0

10

8

IKS4322

PVC

MAT9111005

(4x(2x0,25)+2x0,5)C

9,0

10

8

IKS4103

PUR

MAT9841318

(4x(2x0,25)+2x0,5)C

9,5

10

9

IKS4322

PUR

MAT9841331

(4x(2x0,25)+2x0,5)C

9,5

10

9

IKS4103

TPE

MAT9100001

(4x(2x0,25)+2x0,5)C

9,5

10

11

IKS4322

TPE

MAT9101005

(4x(2x0,25)+2x0,5)C

9,5

10

11

IKS4142

PVC

MAT9110007

(4x(2x0,14)+4x1,0+(4x0,14)C)C

9,0

10

8

IKS4376

PVC

MAT9111004

(4x(2x0,25)+2x0,5)C

9,0

10

8

IKS4142

PUR

MAT9841319

(4x(2x0,14)+(4x0,14)C+4x1,0)C

11,5

10

9

IKS4376

PUR

MAT9841330

(4x(2x0,25)+2x0,5)C

9,5

10

9

IKS4142

TPE

MAT9100007

(4x(2x0,14)+(4x0,14)C+4x1,0)C

11,5

10

11

IKS4376

TPE

MAT9101004

(4x(2x0,25)+2x0,5)C

9,5

10

11

IKS4314

PVC

MAT9110004

(4x(2x0,25)+2x1,0)C

9,5

10

8

IKS4314

PUR

MAT9841320

(4x(2x0,25)+2x1,0)C

9,5

10

9

IKS4314

TPE

MAT9100004

(4x(2x0,25)+2x1,0)C

9,5

10

11

IKS4374

PVC

MAT9110002

(4x(2x0,25)+2x0,5)C

9,0

10

8

RKG0014

PVC

MAT9110030

(3x0,25+3x(2x0,25)C+2x1,0)C

9,0

10

8

IKS4374

PUR

MAT9841321

(4x(2x0,25)+2x0,5)C

9,5

10

9

RKG0014

PUR

MAT9841301

(3x(2x0,25)C+(3x0,25)+2x1,0)C

11,5

10

9

IKS4374

TPE

MAT9100002

(4x(2x0,25)+2x0,5)C

9,5

10

11

RKG0014

TPE

MAT9100030

(3x(2x0,25)C+(3x0,25)+2x1,0)C

11,5

10

11

IKS4375

PVC

MAT9110003

(4x(2x0,25)+2x0,5)C

9,0

10

8

RKG0020

PVC

MAT9110034

(4x(2x0,25)+2x0,5)C

9,0

10

8

IKS4375

PUR

MAT9841322

(4x(2x0,25)+2x0,5)C

9,5

10

9

RKG0020

PUR

MAT9841302

(4x(2x0,25)+2x0,5)C

9,5

10

9

IKS4375

TPE

MAT9100003

(4x(2x0,25)+2x0,5)C

9,5

10

11

RKG0020

TPE

MAT9100034

(4x(2x0,25)+2x0,5)C

9,5

10

11

IKS4384

PVC

MAT9110005

(3x0,25+3x(2x0,25)C+2x1,0)C

9,0

10

8

RKG0026

PVC

MAT9110029

(3x0,25+3x(2x0,25)C+2x1,0)C

9,0

10

8

IKS4384

PUR

MAT9841323

(3x(2x0,25)C+(3x0,25)+2x1,0)C

11,5

10

9

RKG0026

PUR

MAT9841303

(3x(2x0,25)C+(3x0,25)+2x1,0)C

11,5

10

9

IKS4384

TPE

MAT9100005

(3x(2x0,25)C+(3x0,25)+2x1,0)C

11,5

10

11

RKG0026

TPE

MAT9100029

(3x(2x0,25)C+(3x0,25)+2x1,0)C

11,5

10

11

IKS4389

PVC

MAT9110033

(3x0,25+3x(2x0,25)C+2x1,0)C

9,0

10

8

RKG0028

PVC

MAT9110031

(3x0,25+3x(2x0,25)C+2x1,0)C

9,0

10

8

IKS4389

PUR

MAT9841324

(3x(2x0,25)C+(3x0,25)+2x1,0)C

11,5

10

9

RKG0028

PUR

MAT9841304

(3x(2x0,25)C+(3x0,25)+2x1,0)C

11,5

10

9

IKS4389

TPE

MAT9100033

(3x(2x0,25)C+(3x0,25)+2x1,0)C

11,5

10

11

RKG0028

TPE

MAT9100031

(3x(2x0,25)C+(3x0,25)+2x1,0)C

11,5

10

11

RKG4200

PVC

MAT9110013

(4x(2x0,25)+2x0,5)C

9,0

10

8

RKG4200

PUR

MAT9841305

(4x(2x0,25)+2x0,5)C

9,5

10

9

RKG4200

TPE

MAT9100013

(4x(2x0,25)+2x0,5)C

9,5

10

11

8

Connecting cable with adapter plugs IKS0232

PVC

MAT9110009

(2x(2x0,25)+2x0,5)C

7,0

10

8

IKS0232

PUR

MAT9841325

(2x(2x0,25)+2x0,5)C

9,0

10

9

IKS0232

TPE

MAT9100009

(2x(2x0,25)+2x0,5)C

IKS0255

TPE

MAT9100018

(12x0,5)C

IKS0303

PVC

MAT9110019

IKS0303

PUR

MAT9841326

IKS0303

TPE

MAT9100019

(4x(2x0,25)+2x1,0)C

IKS4065

PVC

MAT9111001

(4x(2x0,25)+2x0,5)C

IKS4065

PUR

MAT9841327

(4x(2x0,25)+2x0,5)C

9,5

10

9

IKS4065

TPE

MAT9101001

(4x(2x0,25)+2x0,5)C

9,5

10

11

Basic cable

7,0

10

11

Connecting cable with adapter plugs

11,5

10

25

RKG4201

PVC

MAT9111006

(4x(2x0,25)+2x0,5)C

9,0

10

(4x(2x0,25)+2x1,0)C

9,5

10

8

RKG4201

PUR

MAT9841306

(4x(2x0,25)+2x0,5)C

9,5

10

9

(4x(2x0,25)+2x1,0)C

9,5

10

9

RKG4201

TPE

MAT9101006

(4x(2x0,25)+2x0,5)C

9,5

10

11

9,5

10

11

9,0

10

8

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 434

26

Rexroth readycable® PVC/PUR/TPE

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

435


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:15 Seite 436

SEW readycable® PVC/PUR/TPE

SEW harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

SEW harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to SEW standard (PVC-/PUR-/TPE-Power cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

PVC

MAT9410006

(4 G 1,5)C

10,5

0199 1809 0199 1809

PUR

MAT9861401

(4 G 1,5)C

TPE

MAT9400006

(4 G 1,5)C

0199 1825

PVC

MAT9410007

0199 1825

PUR

MAT9861402

0199 1825

TPE

MAT9400007

0199 1841

PVC

MAT9410008

0199 1841

PUR

0199 1841

TPE

0199 1868

PVC

MAT9410009

0199 1868

PUR

MAT9861404

0199 1868

TPE

MAT9400009

0199 1884

PVC

MAT9410010

0199 1884

PUR

0199 1884

TPE

Page

bending

334

radius [x d]

to 337

PVC

0590 4773 0590 4773

[mm]

Minimum

Page

bending

334

radius [x d]

to 337

0199 5588

PVC

MAT9411010

(4 G 10,0)C

21,0

7,5

1

0199 5588

PUR

MAT9861411

(4 G 10,0)C

18,0

10

6

0199 5588

TPE

MAT9401010

(4 G 10,0)C

19,5

7,5

2

10

6 2

(4 G 2,5)C

12,0

7,5

1

0590 3610

PVC

MAT9411012

(4 G 1,5)C

10,5

7,5

1

(4 G 2,5)C

11,0

10

6

0590 3610

PUR

MAT9861412

(4 G 1,5)C

9,0

10

6

(4 G 2,5)C

11,5

7,5

2

0590 3610

TPE

MAT9401012

(4 G 1,5)C

9,5

7,5

2

(4 G 4,0)C

13,5

7,5

1

MAT9861403

(4 G 4,0)C

12,5

10

6

MAT9400008

(4 G 4,0)C

13,5

7,5

2

(4 G 6,0)C

16,0

7,5

1

Connection cable (Amphenol)

(4 G 6,0)C

14,5

10

6

0199 1906

PVC

13,5

10

4

(4 G 6,0)C

16,0

7,5

2

0199 1906

PVC

MAT9410001

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

(4 G 10,0)C

21,0

7,5

1

0199 1906

PUR

MAT9851401

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

MAT9861405

(4 G 10,0)C

18,0

10

6

0199 1906

PUR

MAT9400001

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

MAT9400010

(4 G 10,0)C

19,5

7,5

2

0199 1922

PVC

MAT9751402

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

0199 1922

PVC

MAT9410002

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

0199 1922

PUR

MAT9851402

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

Extension cable

Harnessed according to SEW standard (PVC-/PUR-Servo cable)

MAT9751401

(4 G 1,5+2x(2x0,75)C)C

0199 1922

PUR

MAT9400002

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

7,5

1

0199 1949

PVC

MAT9751403

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

9,0

10

6

0199 1949

PVC

MAT9410003

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

9,5

7,5

2

0199 1949

PUR

MAT9851403

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

0199 1949

PUR

MAT9400003

(4 G 4,0+2x(2x1,5)C)C

18,0

7,5

7

0199 1965

PVC

MAT9751404

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

MAT9861406

(4 G 1,5)C

TPE

MAT9400012

(4 G 1,5)C

Extension cable (Amphenol)

0199 1965

PVC

MAT9410004

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

10

1

0199 1965

PUR

MAT9851404

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

9,0

10

6

0199 1965

PUR

MAT9400004

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

9,5

7,5

2

0199 1981

PVC

MAT9410005

(4 G 10,0+2x(2x1,5)C)C

24,0

7,5

5

MAT9411006

(4 G 1,5)C

10,5

PUR

MAT9861407

(4 G 1,5)C

TPE

MAT9401006

(4 G 1,5)C

0199 5529

PVC

MAT9411007

(4 G 2,5)C

12,0

10

1

0199 1981

PUR

MAT9851405

(4 G 10,0+2x(2x1,5)C)C

22,0

10

6

0199 5529

PUR

MAT9861408

(4 G 2,5)C

11,0

10

6

0199 1981

PUR

MAT9400005

(4 G 10,0+2x(2x1,5)C)C

23,5

7,5

7

0199 5529

TPE

MAT9401007

(4 G 2,5)C

11,5

7,5

2

0199 5545

PVC

MAT9411008

(4 G 4,0)C

13,5

10

1

0199 5545

PUR

MAT9861409

(4 G 4,0)C

12,5

10

6

0199 5545

TPE

MAT9401008

(4 G 4,0)C

13,5

7,5

2

1332 4861

PVC

MAT9751405

(4 G 1,5+(2x1,5)C)C

12,0

10

4

0199 5561

PVC

MAT9411009

(4 G 6,0)C

16,0

10

1

1332 4861

PVC

MAT9410011

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

0199 5561

PUR

MAT9861410

(4 G 6,0)C

14,5

10

6

1332 4861

PUR

MAT9851406

(4 G 1,5+(2x1,5)C)C

12,0

10

6

0199 5561

TPE

MAT9401009

(4 G 6,0)C

16,0

7,5

2

1332 4861

PUR

MAT9400011

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 436

nominal cross section [mm ]

ø

7,5

PUR

0199 5502

2

9,5

10,5

0199 5502

Part No.

Number of cores and conductor

9,0

(4 G 1,5)C

PVC

material

Part No.

igus®

1

MAT9410012

0199 5502

Jacket

Manufacturer

7,5

Connection cable 0590 4773

Page 334-337

Harnessed according to SEW standard (PVC-/PUR-/TPE-Power cable)

Minimum

Connection cable (Amphenol) 0199 1809

26

SEW readycable® PVC/PUR/TPE

(for up to 10 cuts of the same type)

Connection cable

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

437


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:15 Seite 438

SEW readycable® PVC/PUR

SEW harnessed drive cables ... optionally with PVC-/PUR-jacket

SEW harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to SEW standard (PVC-/PUR-Servo cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

26

SEW readycable® PVC/PUR/TPE

Page 334-337

Harnessed according to SEW standard (PVC-/PUR-/TPE-Encoder cable) Minimum

Page

bending

334

radius [x d]

to 337

Extension cable (Amphenol)

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

Connection cable

0199 2007

PVC

MAT9751406

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

1332 4535

PVC

MAT9741403

(6x(2x0,25))C

9,5

10

8

0199 2007

PVC

MAT9411001

0199 2007

PUR

MAT9851407

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

1332 4551

PUR

MAT9841403

(6x(2x0,25))C

10,0

10

9

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

1332 7429

PVC

MAT9741402

(5x(2x0,25))C

8,5

10

8

0199 2007

PUR

MAT9401001

0199 2023

PVC

MAT9751407

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

1332 7437

PUR

MAT9841402

(5x(2x0,25))C

9,5

10

9

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

0198 9308

PUR

MAT9841404

(3x(2x0,25))C

8,0

10

9

0199 2023

PVC

MAT9411002

0199 2023

PUR

MAT9851408

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

0199 4875

PVC

MAT9741401

(5x(2x0,25))C

8,5

10

8

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

0199 3194

PUR

MAT9841401

(5x(2x0,25))C

9,5

10

9

0199 2023

PUR

MAT9401002

0199 204X

PVC

MAT9751408

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

0199 204X

PVC

MAT9411003

0199 204X

PUR

MAT9851409

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

0199 5421

PVC

MAT9741405

(5x(2x0,25))C

8,5

10

8

0199 204X

PUR

MAT9401003

0199 2066

PVC

MAT9751409

(4 G 4,0+2x(2x1,5)C)C

18,0

7,5

7

0199 5413

PUR

MAT9841405

(5x(2x0,25))C

9,5

10

9

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

0199 5391

PVC

MAT9741406

(6x(2x0,25))C

9,5

10

8

0199 2066

PVC

MAT9411004

0199 2066

PUR

MAT9851410

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

0199 5405

PUR

MAT9841406

(5x(2x0,25))C

10,0

10

9

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

0593 9682

PVC

MAT9741407

(5x(2x0,25))C

8,5

10

8

0199 2066

PUR

MAT9401004

0199 2082

PVC

MAT9411005

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

0593 9682

PUR

MAT9841407

(5x(2x0,25))C

9,5

10

9

(4 G 10,0+2x(2x1,5)C)C

24,0

7,5

5

0199 2082

PUR

0199 2082

PUR

MAT9851411

(4 G 10,0+2x(2x1,5)C)C

22,0

10

6

MAT9401005

(4 G 10,0+2x(2x1,5)C)C

23,5

7,5

7

0593 6500

PVC

MAT9751410

(4 G 1,5+(2x1,5)C)C

12,0

10

4

0593 6500

PVC

MAT9411011

0593 6500

PUR

MAT9851412

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

(4 G 1,5+(2x1,5)C)C

12,0

10

6

0593 6500

PUR

MAT9401011

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

Extension cable

Extension cable

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 438

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

439


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:15 Seite 440

Siemens readycable® PVC/PUR/TPE

Siemens harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

Siemens harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Siemens standard (PVC-/PUR-/TPE-Power cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

26

Siemens readycable® PVC/PUR/TPE

Page 334-337

Harnessed according to Siemens standard (PVC-/PUR-/TPE-Power cable) Page

bending

334

radius [x d]

to 337

Basic cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

7,5

1

Basic cable

6FX8002-5CA01

PVC

MAT9150001

(4 G 1,5)C

10,5

7,5

1

6FX8002-5CS01

PVC

MAT9150020

(4 G 1,5)C

6FX8002-5CA01 6FX8002-5CA01

PUR

MAT9861504

(4 G 1,5)C

TPE

MAT9050001

(4 G 1,5)C

6FX8002-5CA11

PVC

MAT9150002

6FX8002-5CA11

PUR

MAT9861505

6FX8002-5CA11

TPE

MAT9050002

(4 G 2,5)C

9,0

10

6

6FX8002-5CS01

PUR

MAT9861512

(4 G 1,5)C

9,0

10

6

9,5

7,5

2

6FX8002-5CS01

PUR

MAT9861501

(4 G 1,5)C

10,5

7,5

7

(4 G 2,5)C

12,0

7,5

1

6FX8002-5CS01

TPE

MAT9050020

(4 G 1,5)C

9,5

7,5

2

(4 G 2,5)C

11,0

10

6

6FX8002-5CS21

PVC

MAT9150021

(4 G 1,5)C

10,5

7,5

1

11,5

7,5

2

6FX8002-5CS21

PUR

MAT9861513

(4 G 1,5)C

9,0

10

6

6FX8002-5CS21

PUR

MAT9861502

(4 G 1,5)C

10,5

7,5

7

6FX8002-5CS21

TPE

MAT9050021

(4 G 1,5)C

9,5

7,5

2

6FX8002-5CS31

PVC

MAT9150022

(4 G 2,5)C

12,0

7,5

1

Basic cable

10,5

6FX8002-5CA21

PVC

MAT9150003

(4 G 1,5)C

10,5

7,5

1

6FX8002-5CS31

PUR

MAT9861514

(4 G 2,5)C

11,0

10

6

6FX8002-5CA21

PUR

MAT9861506

(4 G 1,5)C

9,0

10

6

6FX8002-5CS31

PUR

MAT9861503

(4 G 2,5)C

12,5

7,5

7

6FX8002-5CA21

TPE

MAT9050003

(4 G 1,5)C

9,5

7,5

2

6FX8002-5CS31

TPE

MAT9050022

(4 G 2,5)C

11,5

7,5

2

6FX8002-5CA31

PVC

MAT9150004

(4 G 2,5)C

12,0

7,5

1

6FX8002-5CA31

PUR

MAT9861507

(4 G 2,5)C

11,0

10

6

6FX8002-5CA31

TPE

MAT9050004

(4 G 2,5)C

11,5

7,5

2

6FX8002-5CA41

PVC

MAT9150005

(4 G 4,0)C

13,5

7,5

1

6FX8002-5CA05

PVC

MAT9151001

(4 G 1,5)C

10,5

7,5

1

6FX8002-5CA41

PUR

MAT9861508

(4 G 4,0)C

12,5

10

6

6FX8002-5CA05

PUR

MAT9861515

(4 G 1,5)C

9,0

10

6

6FX8002-5CA41

TPE

MAT9050005

(4 G 4,0)C

13,5

7,5

2

6FX8002-5CA05

TPE

MAT9051001

(4 G 1,5)C

9,5

7,5

2

6FX8002-5CA51

PVC

MAT9150006

(4 G 6,0)C

16,0

7,5

1

6FX8002-5CA15

PVC

MAT9151002

(4 G 2,5)C

12,0

7,5

1

6FX8002-5CA51

PUR

MAT9861509

(4 G 6,0)C

14,5

10

6

6FX8002-5CA15

PUR

MAT9861516

(4 G 2,5)C

11,0

10

6

6FX8002-5CA51

TPE

MAT9050006

(4 G 6,0)C

16,0

7,5

2

6FX8002-5CA15

TPE

MAT9051002

(4 G 2,5)C

11,5

7,5

2

6FX8002-5CA61

PVC

MAT9150007

(4 G 10,0)C

21,0

7,5

1

6FX8002-5CA61

PUR

MAT9861510

(4 G 10,0)C

18,0

10

6

6FX8002-5CA61

TPE

MAT9050007

(4 G 10,0)C

19,5

7,5

2

Extension cable

Basic cable 6FX8002-5CA13

PVC

MAT9150009

(4 G 10,0)C

21,0

7,5

1

6FX8002-5CA13

PUR

MAT9861524

(4 G 10,0)C

18,0

10

6

6FX8002-5CA13

TPE

MAT9050009

(4 G 10,0)C

19,5

7,5

2

6FX8002-5CA23

PVC

MAT9150008

(4 G 16,0)C

24,0

7,5

1

6FX8002-5CA23

PUR

MAT9861511

(4 G 16,0)C

21,5

10

6

6FX8002-5CA23

TPE

MAT9050008

(4 G 16,0)C

23,0

7,5

2

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 440

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

441


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:15 Seite 442

Siemens readycable® PVC/PUR/TPE

Siemens harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

Siemens harnessed drive cables ... optionally with PVC-/PUR-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Siemens standard (PVC-/PUR-/TPE-Power cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page 334-337

Harnessed according to Siemens standard (PVC-/PUR-Servo cable) Page

bending

334

radius [x d]

to 337

Extension cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø

Minimum

Page

bending

334

radius [x d]

to 337

12,0

10

4

[mm]

Basic cable

6FX8002-5CA28

PVC

MAT9151003

(4 G 1,5)C

10,5

7,5

1

6FX8002-5DA01

PVC

6FX8002-5CA28 6FX8002-5CA28

PUR

MAT9861517

(4 G 1,5)C

TPE

MAT9051003

(4 G 1,5)C

9,0

10

6

6FX8002-5DA01

PVC

MAT9160001

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

9,5

7,5

2

6FX8002-5DA01

PUR

MAT9851501

(4 G 1,5+(2x1,5)C)C

12,0

10

6

6FX8002-5CA38

PVC

MAT9151004

6FX8002-5CA38

PUR

MAT9861518

(4 G 2,5)C

12,0

7,5

1

6FX8002-5DA01

PUR

MAT9060001

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

(4 G 2,5)C

11,0

10

6

6FX8002-5DA11

PVC

MAT9751502

(4 G 2,5+(2x1,5)C)C

13,5

10

4

6FX8002-5CA38

TPE

MAT9051004

6FX8002-5CA48

PVC

MAT9151005

(4 G 2,5)C

11,5

7,5

2

6FX8002-5DA11

PVC

MAT9160002

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

(4 G 4,0)C

13,5

7,5

1

6FX8002-5DA11

PUR

MAT9851502

(4 G 2,5+(2x1,5)C)C

13,5

10

6

6FX8002-5CA48

PUR

6FX8002-5CA48

TPE

MAT9861519

(4 G 4,0)C

12,5

10

6

6FX8002-5DA11

PUR

MAT9060002

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

MAT9051005

(4 G 4,0)C

13,5

7,5

2

6FX8002-5CA58

PVC

MAT9151006

6FX8002-5CA58

PUR

MAT9861520

(4 G 6,0)C

16,0

7,5

1

(4 G 6,0)C

14,5

10

6

6FX8002-5CA58

TPE

MAT9051006

6FX8002-5CA68

PVC

MAT9151007

(4 G 6,0)C

16,0

7,5

2

6FX8002-5DA21

PVC

MAT9751503

(4 G 1,5+(2x1,5)C)C

12,0

10

4

(4 G 10,0)C

21,0

7,5

1

6FX8002-5DA21

PVC

MAT9160003

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

6FX8002-5CA68

PUR

6FX8002-5CA68

TPE

MAT9861521

(4 G 10,0)C

18,0

10

6

6FX8002-5DA21

PUR

MAT9851503

(4 G 1,5+(2x1,5)C)C

12,0

10

6

MAT9051007

(4 G 10,0)C

19,5

7,5

2

6FX8002-5DA21

PUR

MAT9060003

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

6FX8002-5DA31

PVC

MAT9751504

(4 G 2,5+(2x1,5)C)C

13,5

10

4

6FX8002-5DA31

PVC

MAT9160004

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

Extension cable

MAT9751501

(4 G 1,5+(2x1,5)C)C

Basic cable

6FX8002-5DA31

PUR

MAT9851504

(4 G 2,5+(2x1,5)C)C

13,5

10

6

7,5

1

6FX8002-5DA31

PUR

MAT9060004

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

18,0

10

6

6FX8002-5DA41

PVC

MAT9751505

(4 G 4,0+(2x1,5)C)C

15,0

10

4

19,5

7,5

2

6FX8002-5DA41

PVC

MAT9160005

(4 G 4,0+(2x1,5)C)C

15,5

7,5

5

(4 G 16,0)C

24,0

7,5

1

6FX8002-5DA41

PUR

MAT9851505

(4 G 4,0+(2x1,5)C)C

15,0

10

6

(4 G 16,0)C

21,5

10

6

6FX8002-5DA41

PUR

MAT9060005

(4 G 4,0+(2x1,5)C)C

16,0

7,5

7

22,0

7,5

2

6FX8002-5DA51

PVC

MAT9751506

(4 G 6,0+(2x1,5)C)C

16,5

10

4

6FX8002-5DA51

PVC

MAT9160006

(4 G 6,0+(2x1,5)C)C

18,0

7,5

5

6FX8002-5DA51

PUR

MAT9851506

(4 G 6,0+(2x1,5)C)C

16,5

10

6

6FX8002-5DA51

PUR

MAT9060006

(4 G 6,0+(2x1,5)C)C

17,5

7,5

7

6FX8002-5DA61

PVC

MAT9160007

(4 G 10,0+(2x1,5)C)C

22,5

7,5

5

6FX8002-5DA61

PUR

MAT9851507

(4 G 10,0+(2x1,5)C)C

20,5

10

6

6FX8002-5DA61

PUR

MAT9060007

(4 G 10,0+(2x1,5)C)C

21,5

7,5

7

6FX8002-5CX18

PVC

MAT9151009

(4 G 10,0)C

21,0

6FX8002-5CX18 6FX8002-5CX18

PUR

MAT9861522

(4 G 10,0)C

TPE

MAT9051009

(4 G 10,0)C

6FX8002-5CX28

PVC

MAT9151008

6FX8002-5CX28

PUR

MAT9861523

6FX8002-5CX28

TPE

MAT9051008

(4 G 16,0)C

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 442

26

Siemens readycable® PVC/PUR

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

443


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:15 Seite 444

Siemens readycable® PVC/PUR

Siemens harnessed drive cables ... optionally with PVC-/PUR-jacket

Siemens harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Siemens standard (PVC-/PUR-Servo cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Page 334-337

Harnessed according to Siemens standard (PVC-/PUR-/TPE-Signal cable) Minimum

Page

bending

334

radius [x d]

to 337

Basic cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø

Minimum

Page

bending

334

radius [x d]

to 337

12,0

10

4

[mm]

Extension cable

6FX8002-5DA23

PVC

MAT9160008

(4 G 16,0+(2x1,5)C)C

24,5

7,5

5

6FX8002-5DA28

PVC

6FX8002-5DA23

PUR

MAT9851508

(4 G 16,0+(2x1,5)C)C

6FX8002-5DA23

PUR

MAT9060008

(4 G 16,0+(2x1,5)C)C

24,0

10

6

6FX8002-5DA28

PVC

MAT9161003

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

24,5

7,5

7

6FX8002-5DA28

PUR

MAT9851514

(4 G 1,5+(2x1,5)C)C

12,0

10

6

6FX8002-5DA33

PVC

MAT9160009

(4 G 25,0+(2x1,5)C)C

6FX8002-5DA33

PUR

MAT9060009

(4 G 25,0+(2x1,5)C)C

29,5

7,5

5

6FX8002-5DA28

PUR

MAT9061003

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

28,5

7,5

7

6FX8002-5DA38

PVC

MAT9751512

(4 G 2,5+(2x1,5)C)C

13,5

10

4

6FX8002-5DA43

PVC

MAT9160010

(4 G 35,0+(2x1,5)C)C

6FX8002-5DA43

PUR

MAT9060010

(4 G 35,0+(2x1,5)C)C

33,0

7,5

5

6FX8002-5DA38

PVC

MAT9161004

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

32,5

7,5

7

6FX8002-5DA38

PUR

MAT9851515

(4 G 2,5+(2x1,5)C)C

13,5

10

6

6FX8002-5DA38

PUR

MAT9061004

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

6FX8002-5DA48

PVC

MAT9751513

(4 G 4,0+(2x1,5)C)C

15,0

10

4

Basic cable

MAT9751511

(4 G 1,5+(2x1,5)C)C

6FX8002-5DA48

PVC

MAT9161005

(4 G 4,0+(2x1,5)C)C

15,5

7,5

5

12,0

10

4

6FX8002-5DA48

PUR

MAT9851516

(4 G 4,0+(2x1,5)C)C

15,0

10

6

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

6FX8002-5DA48

PUR

MAT9061005

(4 G 4,0+(2x1,5)C)C

16,0

7,5

7

(4 G 1,5+(2x1,5)C)C

12,0

10

6

6FX8002-5DA58

PVC

MAT9751514

(4 G 6,0+(2x1,5)C)C

16,5

10

4

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

6FX8002-5DA58

PVC

MAT9161006

(4 G 6,0+(2x1,5)C)C

18,0

7,5

5

(4 G 1,5+(2x1,5)C)C

12,0

10

4

6FX8002-5DA58

PUR

MAT9851517

(4 G 6,0+(2x1,5)C)C

16,5

10

6

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

6FX8002-5DA58

PUR

MAT9061006

(4 G 6,0+(2x1,5)C)C

17,5

7,5

7

(4 G 1,5+(2x1,5)C)C

12,0

10

6

6FX8002-5DA68

PVC

MAT9161007

(4 G 10,0+(2x1,5)C)C

22,5

7,5

5

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

6FX8002-5DA68

PUR

MAT9851518

(4 G 10,0+(2x1,5)C)C

20,5

10

6

(4 G 10,0+(2x1,5)C)C

22,5

7,5

5

6FX8002-5DA68

PUR

MAT9061007

(4 G 10,0+(2x1,5)C)C

21,5

7,5

7

MAT9851511

(4 G 10,0+(2x1,5)C)C

20,5

10

6

MAT9060022

(4 G 10,0+(2x1,5)C)C

21,5

7,5

7

6FX8002-5DX18

PUR

MAT9851520

(4 G 10,0+(2x1,5)C)C

20,5

10

6

6FX8002-5DS01

PVC

MAT9751507

6FX8002-5DS01

PVC

MAT9160020

6FX8002-5DS01

PUR

MAT9851509

6FX8002-5DS01

PUR

MAT9060020

6FX8002-5DS21

PVC

MAT9751508

6FX8002-5DS21

PVC

MAT9160021

6FX8002-5DS21

PUR

MAT9851510

6FX8002-5DS21

PUR

MAT9060021

6FX8002-5DS61

PVC

MAT9160022

6FX8002-5DS61

PUR

6FX8002-5DS61

PUR

(4 G 1,5+(2x1,5)C)C

Extension cable 6FX8002-5DA05

PVC

MAT9751509

6FX8002-5DA05

PVC

MAT9161001

6FX8002-5DA05

PUR

MAT9851512

Extension cable

6FX8002-5DX28

PVC

MAT9161008

(4 G 16,0+(2x1,5)C)C

24,5

7,5

5

12,0

10

4

6FX8002-5DX28

PUR

MAT9851519

(4 G 16,0+(2x1,5)C)C

24,0

10

6

(4 G 1,5+(2x1,5)C)C

13,0

7,5

5

6FX8002-5DX28

PUR

MAT9061008

(4 G 16,0+(2x1,5)C)C

24,5

7,5

7

(4 G 1,5+(2x1,5)C)C

12,0

10

6

6FX8002-5DX38

PVC

MAT9161009

(4 G 25,0+(2x1,5)C)C

29,5

7,5

5

(4 G 1,5+(2x1,5)C)C

6FX8002-5DA05

PUR

MAT9061001

(4 G 1,5+(2x1,5)C)C

13,0

7,5

7

6FX8002-5DX38

PUR

MAT9061009

(4 G 25,0+(2x1,5)C)C

28,5

7,5

7

6FX8002-5DA15

PVC

MAT9751510

(4 G 2,5+(2x1,5)C)C

13,5

10

4

6FX8002-5DX48

PVC

MAT9161010

(4 G 35,0+(2x1,5)C)C

33,0

7,5

5

6FX8002-5DA15

PVC

MAT9161002

(4 G 2,5+(2x1,5)C)C

14,0

7,5

5

6FX8002-5DX48

PUR

MAT9061010

(4 G 35,0+(2x1,5)C)C

32,5

7,5

7

6FX8002-5DA15

PUR

MAT9851513

(4 G 2,5+(2x1,5)C)C

13,5

10

6

6FX8002-5DA15

PUR

MAT9061002

(4 G 2,5+(2x1,5)C)C

14,5

7,5

7

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 444

26

Siemens readycable® PVC/PUR/TPE

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

445


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:15 Seite 446

Siemens readycable® PVC/PUR/TPE

Siemens harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

Siemens harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Siemens standard (PVC-/PUR-/TPE-Signal cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

PVC

6FX8002-2AD00 6FX8002-2AD00 6FX8002-2CA11

PVC

MAT9170002

(4x(2x0,34)+4x0,5)C

6FX8002-2CA11

PUR

MAT9841502

(4x(2x0,34)+4x0,5)C

6FX8002-2CA11

TPE

MAT9070002

(4x(2x0,34)+4x0,5)C

6FX8002-2CA15

PVC

MAT9170003

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

6FX8002-2CA15

PUR

MAT9841503

6FX8002-2CA15

TPE

MAT9070003

Page

bending

334

radius [x d]

to 337

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

6FX8002-2CD01

PVC

MAT9170010

(4x(2x0,34)+4x0,5)C

9,0

10

8

6FX8002-2CD01

PUR

MAT9841510

(4x(2x0,34)+4x0,5)C

10,5

10

9

6FX8002-2CD01

TPE

MAT9070010

(4x(2x0,34)+4x0,5)C

10,5

10

11

MAT9170001

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

9,0

10

8

PUR

MAT9841501

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

10,5

10

9

TPE

MAT9070001

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

10,5

10

11

9,0

10

8

6FX8002-2CF01

PVC

MAT9170021

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

9,0

10

8

10,5

10

9

6FX8002-2CF01

PUR

MAT9841519

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

10,5

10

9

10,5

10

11

6FX8002-2CF01

TPE

MAT9070021

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

10,5

10

11

9,0

10

8

6FX8002-2CF02

PVC

MAT9170011

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

9,0

10

8

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

10,5

10

9

6FX8002-2CF02

PUR

MAT9841511

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

10,5

10

9

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

10,5

10

11

6FX8002-2CF02

TPE

MAT9070011

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

10,5

10

11

6FX8002-2CG00

PVC

MAT9170012

(4x(2x0,34)+4x0,5)C

9,0

10

8

6FX8002-2CG00

PUR

MAT9841512

(4x(2x0,34)+4x0,5)C

10,5

10

9

6FX8002-2CG00

TPE

MAT9070012

(4x(2x0,34)+4x0,5)C

10,5

10

11

Basic cable 6FX8002-2CA31

PVC

MAT9170004

(3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C

6FX8002-2CA31 6FX8002-2CA31

9,5

10

PUR

MAT9841504

(3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C

11,0

10

9

TPE

MAT9070004

(3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C

11,0

10

11

6FX8002-2CA51

PVC

6FX8002-2CA51 6FX8002-2CA51 6FX8002-2CA71

PVC

MAT9170006

(4x(2x0,34)+4x0,5)C

6FX8002-2CA71

PUR

MAT9841506

(4x(2x0,34)+4x0,5)C

6FX8002-2CA71

TPE

MAT9070006

(4x(2x0,34)+4x0,5)C

10,5

Basic cable

8

Basic cable

Basic cable 6FX8002-2CH00

PVC

MAT9170013

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

9,0

10

8

6FX8002-2CH00

PUR

MAT9841513

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

10,5

10

9

6FX8002-2CH00

TPE

MAT9070013

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

10,5

10

11

MAT9170005

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

9,0

10

PUR

MAT9841505

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

10,5

10

9

TPE

MAT9070005

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

10,5

10

11

9,0

10

8

6FX8002-2CK00

PVC

MAT9170014

(3x(2x0,14)C+2x(0,5)C)C

9,0

10

8

10,5

10

9

6FX8002-2CK00

PUR

MAT9841514

(3x(2x0,14)C+2x(0,5)C)C

10,5

10

9

10

11

6FX8002-2CK00

TPE

MAT9070014

(3x(2x0,14)C+2x(0,5)C)C

10,5

10

11

6FX8002-2CL00

PVC

MAT9170015

(3x(2x0,14)C+2x(0,5)C)C

9,0

10

8

6FX8002-2CL00

PUR

MAT9841515

(3x(2x0,14)C+2x(0,5)C)C

10,5

10

9

6FX8002-2CL00

TPE

MAT9070015

(3x(2x0,14)C+2x(0,5)C)C

10,5

10

11

8

8

Basic cable

Basic cable

6FX8002-2CB31

PUR

MAT9841507

(14 x 0,25)C

8,0

5

13

6FX8002-2CB31

TPE

MAT9070007

(12x0,25)C

9,5

10

25

6FX8002-2CB51

PVC

MAT9170008

(4x(2x0,34)+4x0,5)C

9,0

10

8

6FX8002-2CB51

PUR

MAT9841508

(4x(2x0,34)+4x0,5)C

10,5

10

9

6FX8002-2AH00

PVC

MAT9170018

(4x(2x0,34)+4x0,5)C

9,0

10

Basic cable

6FX8002-2CB51

TPE

MAT9070008

(4x(2x0,34)+4x0,5)C

10,5

10

11

6FX8002-2AH00

PUR

MAT9841518

(4x(2x0,34)+4x0,5)C

10,5

10

9

6FX8002-2CC11

PVC

MAT9170009

(4x(2x0,34)+4x0,5)C

9,0

10

8

6FX8002-2AH00

TPE

MAT9070018

(4x(2x0,34)+4x0,5)C

10,5

10

11

6FX8002-2CC11

PUR

MAT9841509

(4x(2x0,34)+4x0,5)C

10,5

10

9

6FX8002-2CC11

TPE

MAT9070009

(4x(2x0,34)+4x0,5)C

10,5

10

11

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 446

Page 334-337

Harnessed according to Siemens standard (PVC-/PUR-/TPE-Signal cable)

Minimum

Basic cable 6FX8002-2AD00

26

Siemens readycable® PVC/PUR/TPE

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

447


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:16 Seite 448

Siemens readycable® PVC/PUR

Siemens harnessed drive cables ... optionally with PVC-/PUR-jacket

Siemens harnessed drive cables ... optionally with PVC-/PUR-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Siemens standard (PVC-/PUR-Servo cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Page

bending

334

radius [x d]

to 337

Manufacturer Part No.

PVC

MAT9170016

(3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C

10

6FX8002-2EQ00

PUR

MAT9841516

(3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C

11,0

10

9

6FX8002-2EQ00

TPE

MAT9070016

(3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C

11,0

10

11

6FX8002-2EQ10

PVC

MAT9170017

(3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C

10

6FX8002-2EQ10

PUR

MAT9841517

(3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C

11,0

10

9

6FX8002-2EQ10

TPE

MAT9070017

(3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C

11,0

10

11

6FX8002-2AD04

PVC

MAT9171001

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

9,0

10

8

6FX8002-2AD04

PUR

MAT9841520

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

10,5

10

9

6FX8002-2AD04

TPE

MAT9071001

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

10,5

10

11

6FX8002-2AH04

PVC

MAT9171018

(4x(2x0,34)+4x0,5)C

9,0

10

8

6FX8002-2AH04

PUR

MAT9841529

(4x(2x0,34)+4x0,5)C

10,5

10

9

6FX8002-2AH04

TPE

MAT9071018

(4x(2x0,34)+4x0,5)C

10,5

10

11

6FX8002-2CA34

PVC

MAT9171004

(3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C

9,5

10

8

6FX8002-2CA34

PUR

MAT9841523

(3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C

11,0

10

9

6FX8002-2CA34

TPE

MAT9071004

(3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C

11,0

10

11

6FX8002-2CA54

PVC

MAT9171003

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

9,0

10

8

6FX8002-2CA54

PUR

MAT9841522

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

10,5

10

9

6FX8002-2CA54

TPE

MAT9071003

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

10,5

10

11

6FX8002-2CB34

PUR

MAT9841525

(14 x 0,25)C

8,0

5

13

6FX8002-2CB34

TPE

MAT9071007

(12x0,25)C

9,5

10

25

6FX8002-2CB54

PVC

MAT9171002

(4x(2x0,34)+4x0,5)C

9,0

10

8

8

material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

PVC

MAT9171017

(3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C

9,5

10

8

6FX8002-2EQ14

PUR

MAT9841528

(3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C

11,0

10

9

TPE

MAT9071017

(3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C

11,0

10

11

Harnessed according to Siemens standard (PUR-Signal cable)

8

Basic cable

Jacket

6FX8002-2EQ14 6FX8002-2EQ14 6FX8002-2EQ00

9,5

Page 334-337

Harnessed according to Siemens standard (PVC-/PUR-Servo cable) Minimum

Basic cable 9,5

26

Siemens readycable® PVC/PUR

Basic cable 6FX8002-2DC10

PUR

MAT9070030

(2x(2x0,15)+(2x0,38))C

7,5

12

9

6FX8002-2DC20

PUR

MAT9070031

(2x(2x0,15)+(2x0,38))C

7,5

12

9

6FX8002-1DC00

PUR

MAT9070032

(2x(2x0,15)+(2x0,38))C

7,5

12

9

Extension cable

6FX8002-2CB54

PUR

MAT9841521

(4x(2x0,34)+4x0,5)C

10,5

10

9

6FX8002-2CB54

TPE

MAT9071002

(4x(2x0,34)+4x0,5)C

10,5

10

11

6FX8002-2CC14

PVC

MAT9171009

(4x(2x0,34)+4x0,5)C

9,0

10

8

6FX8002-2CC14

PUR

MAT9841526

(4x(2x0,34)+4x0,5)C

10,5

10

9

6FX8002-2CC14

TPE

MAT9071009

(4x(2x0,34)+4x0,5)C

10,5

10

11

6FX8002-2CF04

PVC

MAT9171011

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

9,0

10

8

6FX8002-2CF04

PUR

MAT9841527

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

10,5

10

9

6FX8002-2CF04

TPE

MAT9071011

(3x(2x0,14)C+(4x0,14)+(2x0,5))C

10,5

10

11

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 448

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

449


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:16 Seite 450

Stöber readycable® PVC/PUR

Stöber harnessed drive cables ... optionally with PVC-/PUR-jacket

Stöber harnessed drive cables ... optionally with PVC-/PUR-/TPE-jacket

● Technical information Selection table 1 to

● Technical information Selection table 1 to

26

Page 334-337

Harnessed according to Stöber standard (PVC-/PUR-Servo cable) Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Page 334-337

Harnessed according to Stöber standard (PVC-/PUR-/TPE-Encoder cable) Minimum

Page

bending

334

radius [x d]

to 337

iMDS5000 & iSDS4000 Basic cable

Manufacturer Part No.

Jacket material

igus® Part No.

Number of cores and conductor 2

nominal cross section [mm ]

ø [mm]

Minimum

Page

bending

334

radius [x d]

to 337

10

8

iSDS4000 Basic cable

Gr.1-Motor-1,0mm²

PVC

MAT9751601

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

Encoder ED/EK iSDS4000 PVC

MAT9431001

(4x(2x0,34)+4x0,5)C

9,0

Gr.1-Motor-1,0mm²

PVC

MAT9430001

Gr.1-Motor-1,0mm²

PUR

MAT9851601

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

5

Encoder ED/EK iSDS4000 PUR

MAT9841601

(4x(2x0,34)+4x0,5)C

10,5

10

9

(4 G 1,0+2x(2x0,75)C)C

13,0

10

6

Encoder ED/EK iSDS4000 TPE

MAT9941601

(4x(2x0,34)+4x0,5)C

9,5

12

10

Gr.1-Motor-1,0mm²

PUR

MAT9420001

Gr.1-Motor-1,5mm²

PVC

MAT9751602

(4 G 1,0+2x(2x0,75)C)C

13,5

7,5

7

Encoder ED/EK iSDS4000 TPE

MAT9421001

(4x(2x0,34)+4x0,5)C

10,5

10

11

(4 G 1,5+2x(2x0,75)C)C

13,5

10

4

Gr.1-Motor-1,5mm²

PVC

MAT9430002

Gr.1-Motor-1,5mm²

PUR

MAT9851602

(4 G 1,5+2x(2x0,75)C)C

14,5

7,5

5

(4 G 1,5+2x(2x0,75)C)C

13,5

10

6

iSDS4000 Basic cable

Gr.1-Motor-1,5mm²

PUR

MAT9420002

Gr.1-Motor-2,5mm²

PVC

MAT9751603

(4 G 1,5+2x(2x0,75)C)C

14,0

7,5

7

Resolver iSDS4000

PVC

MAT9431003

(4x(2x0,25)+2x0,5)C

9,0

10

8

(4 G 2,5+2x(2x1,5)C)C

15,5

10

4

Resolver iSDS4000

PUR

MAT9841603

(4x(2x0,25)+2x0,5)C

9,5

10

9

Gr.1-Motor-2,5mm²

PVC

MAT9430003

Gr.1-Motor-2,5mm²

PUR

MAT9851603

(4 G 2,5+2x(2x1,5)C)C

17,0

7,5

5

Resolver iSDS4000

TPE

MAT9421003

(4x(2x0,25)+2x0,5)C

9,5

10

11

(4 G 2,5+2x(2x1,5)C)C

15,5

10

6

Gr.1-Motor-2,5mm²

PUR

MAT9420003

Gr.1-Motor-4,0mm²

PVC

MAT9751604

(4 G 2,5+2x(2x1,5)C)C

16,5

7,5

7

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

iSDS4000 Basic cable

Gr.1-Motor-4,0mm²

PVC

MAT9430004

Gr.1-Motor-4,0mm²

PUR

MAT9851604

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

Encoder ES iSDS4000

PUR

MAT9841602

(3x(2x0,5+2x0,25)+(4x0,25))C

11,0

12

9

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

Encoder ES iSDS4000

TPE

MAT9941602

(6x0,5+5x2x0,25)C

10,0

12

10

Gr.1-Motor-4,0mm²

PUR

MAT9420004

(4 G 4,0+2x(2x1,5)C)C

18,0

7,5

7

Encoder ES iSDS4000

TPE

MAT9421002

(3x(2x0,5+2x0,25)+(4x0,25))C

11,0

10

11

iMDS5000 & iSDS4000 Basic cable

iMDS5000 Basic cable

Gr.1,5-Motor-4,0mm²

PVC

MAT9751605

(4 G 4,0+2x(2x1,5)C)C

17,0

10

4

Encoder iMDS5000

PVC

MAT9431004

(4x(2x0,25)+2x0,5)C

9,0

10

8

Gr.1,5-Motor-4,0mm²

PVC

MAT9430005

(4 G 4,0+2x(2x1,5)C)C

18,5

7,5

5

Encoder iMDS5000

PUR

MAT9841604

(4x(2x0,25)+2x0,5)C

9,5

10

9

Gr.1,5-Motor-4,0mm²

PUR

MAT9851605

(4 G 4,0+2x(2x1,5)C)C

17,0

10

6

Encoder iMDS5000

TPE

MAT9421004

(4x(2x0,25)+2x0,5)C

9,5

10

11

Gr.1,5-Motor-4,0mm²

PUR

MAT9420005

(4 G 4,0+2x(2x1,5)C)C

18,0

7,5

7

Encoder HTL

PVC

MAT9431006

(4x(2x0,25)+2x0,5)C

9,0

10

8

Gr.1,5-Motor-6,0mm²

PVC

MAT9751606

(4 G 6,0+2x(2x1,5)C)C

18,5

10

4

Encoder HTL

PUR

MAT9841606

(4x(2x0,25)+2x0,5)C

9,5

10

9

Gr.1,5-Motor-6,0mm²

PVC

MAT9430006

(4 G 6,0+2x(2x1,5)C)C

21,0

7,5

5

Encoder HTL

TPE

MAT9421006

(4x(2x0,25)+2x0,5)C

9,5

10

11

Gr.1,5-Motor-6,0mm²

PUR

MAT9851606

(4 G 6,0+2x(2x1,5)C)C

18,5

10

6

Gr.1,5-Motor-6,0mm²

PUR

MAT9420006

(4 G 6,0+2x(2x1,5)C)C

20,0

7,5

7

8

Gr.1,5-Motor-10,0mm²

PVC

MAT9430007

(4 G 10,0+2x(2x1,5)C)C

24,0

7,5

5

iMDS5000 Basic cable

Gr.1,5-Motor-10,0mm²

PUR

MAT9851607

(4 G 10,0+2x(2x1,5)C)C

22,0

10

6

Resolver iMDS5000

PVC

MAT9431005

(3x(2x0,25)C)C

11,0

10

Gr.1,5-Motor-10,0mm²

PUR

MAT9420007

(4 G 10,0+2x(2x1,5)C)C

23,5

7,5

7

Resolver iMDS5000

PUR

MAT9841605

(3 x (2 x 0,25))C

8,0

10

9

Resolver iMDS5000

TPE

MAT9421005

(3 x (2 x 0,25))C

7,5

10

11

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ... 450

26

Stöber readycable® PVC/PUR/TPE

(for up to 10 cuts of the same type)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary, jacket colour can be different. igus® gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

451


®

igus connectors igus®

Connectors

Type

SERIES A

Signal connector

Page

Connectors 408

M23 standard [6 to 19-pin]

SERIES B

Power connector

412

Size 1 [6, 8 and 9-pin]

SERIES B

Power connector

414

Size 1 [6, 8 and 9-pin]

SERIES M17

Signal and power connector

415

M17 signal [17-pin] and power connector [4 to 9-pin]

SERIES C

Power connector

418

Size 1,5 [6, 8 and 9-pin]

SERIES D

Power connector

420

Size 3 [6 und 8-pin]

SERIES S

Power connector

422

Single-pin

SUB-D

Tools, accessories

424

Signal connector

426

SUB-D Standard [9 to 44-pin]

®

igusconnectors

EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:17 Seite 452

Yamaichi Y-CONKIT

Glands

506

430

Test igus®! Order the service-pack today, get it tomorrow – from batch size 1 The package contains: Your ordered connector together with contacts, installation instructions and a faxback order form. Just call us! Tel. +49(0)2203/9649-800

453


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:17 Seite 454

SERIES A

igus® connectors SERIES A

SERIES A

according to Intercontec standard Signal connector M23 standard [6 to 19-pin] Types ● PG 13.5-installation box

connector

● Installation box straight with flange

● Lead-through

● Installation box angled and turnable flexed with flange

● Extension, standard or with central attachment

Signal plug 8+1 pin, nickel-plated Order no.

P-Type [8+1]-pin, 3 coding slots

8 x female crimping contact 1.0 mm, Clamping area: slitted crimp area: 0.14-1.0 mm2, 9.0-13.2 mm 1 x female crimping 2.0 mm, slitted crimp area: 0.35-2.5 mm2

Metal construction, EMC shielding

MAT0179600

Number of contacts

C1+4

Connector

● Connector, standard and push-pull version, angular

● 6.7, [8+1], 9, 10, 12, 16, 17, [16+3]

Technical data of the SERIES A -20 °C to 130 °C IP 66/67 [plugged] Metal construction, EMC shielding

MAT0179601

Electrical data 16 to [16+3]-pin Max. rated current Rated voltage Test voltage (L-L) Resistance Insertion cycles

9A 125 V (AC/DC) 2500 V < 5 m > 50

Signal plug 16 pin, nickel-plated Order no.

P-Type 16-pin, 1 coding slot

Female crimping contact 1.0 mm, Clamping area: slitted crimp area: 0.14-1.0 mm2 9.0-13.2 mm

Metal construction, EMC shielding

MAT0179602

C1

Data according to VDE 0110/EN 61984, Clause 6.19.2.2

Fax +49(0)2203/9649-222

C1

51147 Cologne, Germany

10 A 160 V (AC/DC) 2500 V < 5 m > 50

Clamping area: 9.0-13.2 mm

info@igus.de

Max. rated current Rated voltage Test voltage (L-L) Resistance Insertion cycles

Female crimping contact 1.0 mm, slitted crimp area: 0.14-1.0 mm2

Tel. +49(0)2203/9649-800

Electrical data 6 to 12-pin

E-Type 12-pin, 3 coding slots

igus® GmbH

Signal plug 12 pin, nickel-plated Order no.

www.igus.eu

Temperature range Protection class

Degree of pollution 3 Over-voltage category III Max. height of operation 2000 m Signal plug 17 pin, nickel-plated Order no.

INTERCONTEC

Used materials Housing Connection nut Insulation insert Contacts Seals Clamping ring

Zinc die-casting/brass, nickel-plated Brass, nickel-plated PA 6.6/PBT, UL 94/V0 Brass, gold-plated FPM/HNBR Brass, nickel-plated

Female crimping contact 1.0 mm, Clamping area: slitted crimp area: 0.14-1.0 mm2 9.0-13.2 mm

C1

P-Type [16+3]-pin, 1 coding slot

16 x female crimping contact 1.0 mm, Clamping area: slitted crimp area: 0.14-1.0 mm2, 9.0-13.2 mm 3 x female crimping 0,5 mm, slitted crimp area: 0.14-1.0 mm2

MAT0179604

Page 469

Housing with SpeedTEC quick-release fastener

+

www.igus.eu/quickpin ®

Metal construction, EMC shielding

MAT0179603

Signal plug 16+3 pin, nickel-plated Order no.

Housing with SpeedTEC quick-release fastener

454

P-Type 17-pin, 3 coding slots

Metal construction, EMC shielding

C1+5

Page 469

... no minimum order quantity

®

igus QuickPin – Configure readycable online

455


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:18 Seite 456

SERIES A

igus® connectors SERIES A

SERIES A

according to Intercontec standard

Lead-through, with connection nut Order no. 8+1 pin

Signal extension 17 pin, nickel-plated Order no.

Metal construction, axial seal

MAT0179605

C1+4

E-Type 17-pin, 3 coding slots

Crimping contact 1.0 mm, crimp area: 0.14-1.0 mm2

Clamping area: 9.0-13.2 mm

Metal construction, EMC shielding

MAT0179613

C1

Order no. 12 pin

MAT0179606

Connector

The straight signal receptacle is assembled with the contacts and insulation bodies. The technical specifications apply accordingly. A cable clamp is not required by virtue of the design.

C1

Order no. 16 pin

MAT0179607

C1

Order no. 17 pin

C1

MAT0179609

C1+5

Signal extension 16+3 pin, nickel-plated Order no.

E-Type [16+3]-pin, 1 coding slot

16 x crimping contact 1.0 mm, crimp area: 0.14-1.0 mm2 3 x crimping contact 0,5 mm, crimp area: 0.14-1.0 mm2

Clamping area: 9.0-13.2 mm

Metal construction, EMC shielding

MAT0179614

Signal extension 8+1 pin, nickel-plated Order no.

E-Type [8+1]-pin, 3 coding slots

8 x crimping contact 1.0 mm, crimp area: 0.14-1.0 mm2 1 x crimping contact 2.0 mm, crimp area: 0.35-2.5 mm2

Clamping area: 9.0-13.2 mm

The extension with a central attachment is assembed with the above-mentioned contacts, insulation bodies and cable clamp. The technical specifications apply accordingly.

Metal construction, EMC shielding

MAT0179610

C1+5

C1+4 Extension with central attachment Order no. 8+1 pin

Metal construction, EMC shielding

MAT0179615

C1+4

Fax +49(0)2203/9649-222

Order no. 16+3 pin

Tel. +49(0)2203/9649-800

MAT0179608

Order no. 12 pin

MAT0179616

C1

Order no. 16 pin Crimping contact 1.0 mm, crimp area: 0.14-1.0 mm2

Clamping area: 9.0-13.2 mm

Metal construction, EMC shielding

MAT0179617

C1

MAT0179618

51147 Cologne, Germany

C1

info@igus.de

Order no. 17 pin

MAT0179611

igus® GmbH

P-Type 12-pin, 3 coding slots

www.igus.eu

Signal extension 12 pin, nickel-plated Order no.

C1

Order no. 16+3 pin

INTERCONTEC

MAT0179619

Signal extension 16 pin, nickel-plated Order no.

E-Type 16-pin, 1 coding slot

Crimping contact 1.0 mm, crimp area: 0.14-1.0 mm2

Metal construction, EMC shielding

MAT0179612

C1

Housing with SpeedTEC quick-release fastener

+ 456

Clamping area: 9.,0-13.2 mm

C1+5

Page 469

Housing with SpeedTEC quick-release fastener

www.igus.eu/quickpin ®

Page 469

... no minimum order quantity

®

igus QuickPin – Configure readycable online

457


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:18 Seite 458

SERIES B

igus® connectors SERIES B

SERIES B

according to Intercontec standard Power connector Size 1 [6, 8 and 9-pin] Types ● Installation box straight with flange

angular connector

● Installation box angled and turnable flexed with flange

● Extension, standard or with central attachment ● Lead-through

Power plug 6 pin, nickel-plated Order no.

P-Type 6-pin

6x HC-female crimping 2.0 mm, Clamping area: 9.5-14.5 mm crimp area: 0.35-2.5 mm2

Metal construction, EMC shielding

MAT0179620

Number of contacts

C2

Connector

● Connector, short and long, push-pull version,

● 6, 8, 9

Technical data of the SERIES B Power plug 8 pin, nickel-plated Order no.

Electrical data power contacts Max. rated current Rated voltage Test voltage (L-L) Resistance Insertion cycles

max. 28 A (6-pin) max. 30 A (8/9-pin) 630 V (AC/DC) 6000 V < 3 m > 50

P-Type 8-pin

4 x HC-female crimping 2.0 mm, Clamping area: Crimp area: 0.35-2.5 mm2 9.5-14.5 mm 4 x HC-female crimping 1,0 mm, Crimp area: 0.14-1.0 mm2

Metal construction, EMC shielding

MAT0179621

C1+2

Electrical data signal 8 u.9 pin Max. rated current Rated voltage Test voltage (L-L) Resistance Insertion cycles

10 A 250 V (AC/DC) 2500 V < 5 m > 50

Power plug 9 pin, nickel-plated Order no.

P-Type 9-pin

4 x HC-female crimping 2.0 mm, Clamping area: 9.5-14.5 mm crimp area: 0.35-2.5 mm2 5 x HC-female crimping 1.0 mm, crimp area: 0.14-1.0 mm2

MAT0179622

Metal construction, EMC shielding

C1+2

Fax +49(0)2203/9649-222

-20 °C to 130 °C IP 66/67 [plugged]

Tel. +49(0)2203/9649-800

Temperature range Protection class

Data according to VDE 0110/EN 61984, Clause 6.19.2.2 Degree of pollution 3 Over-voltage category III Max. height of operation 2000 m

igus® GmbH

51147 Cologne, Germany

www.igus.eu

info@igus.de

The straight signal receptacle is assembled with abovementioned contacts and insulation bodies. The technical specifications apply accordingly. A cable clamp is not required by virtue of the design.

INTERCONTEC

Used materials Housing Connection nut Insulation insert Contacts Seals Clamping ring

Housing with SpeedTEC quick-release fastener

+ 458

Lead-through, with connection nut Order no. 6 pin

Zinc die-casting/brass, nickel-plated * Brass, nickel-plated PA 6.6/PBT, UL 94/V0 Brass, gold-plated FPM/HNBR Brass, nickel-plated *optional: stainless steel

MAT0178406

C2

Order no. 8 pin

MAT0175661

C1+2

Order no. 9 pin

MAT0179033

Page 469

Housing with SpeedTEC quick-release fastener

www.igus.eu/quickpin ®

Metal construction, axial seal

C1+2

Page 469

... no minimum order quantity

®

igus QuickPin – Configure readycable online

459


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:18 Seite 460

SERIES B

igus® connectors SERIES B

igus® connectors SERIES M17

according to Intercontec standard

according to Intercontec standard

Power connector Size 1 [6, 8 and 9-pin]

Signal-und Power connector M17 signal [17-pin] and power connector [4 to 9-pin]

SERIES M17

● Connector, standard and push-pull version

● Installation box angled, turnable with flange

● Extension, standard or with central attachment

● Installation box angled and turnable flexed with flange

● Installation box straight with flange ● Installation box straight, connecting thread M17 x 0,75 Power extension 6 pin, nickel-plated Order no.

E-Type 6-pin

6 x crimping contact 2.0 mm, crimp area: 0.35-2.5 mm2

Clamping area: 9.5-14.5 mm

Number of contacts

Metal construction, EMC shielding

MAT0179623

Connector

Types

● Signal: 17

● Power: 4, 7, 9

C2/C3

Technical data of the M17 SERIES Temperature range Protection class

-20 °C to 130 °C IP 67 [plugged]

Metal construction, EMC shielding

MAT0179624

C3

Electrical data power

E-Type 9-pin

4 x crimping contact 2.0 mm, crimp area: 0.35-2.5 mm2 5 x crimping contact 1.0 mm, crimp area: 0.14-1.0 mm2

Clamping area: 9.5-14.5 mm

Metal construction, EMC shielding

C3

The extension with central attachment is assembed with the above-mentioned contacts, insulation bodies and cable clamp. The technical specifications apply accordingly.

INTERCONTEC

7 pin 1 mm2: 10 A 1,5 mm2: 14 A 630 V (AC /DC) 6000 V < 5 m > 50

Electrical data power 9 pin

MAT0179625

Extension with central attachment Order no. 6 pin

Max. rated current Rated voltage Test voltage (L-L) Resistance Insertion cycles

Signal: 3,6 A Power: 14 A Signal: 63 V [AC/DC ] Power: 630 V [AC/DC ] Signal: 1500 V Power: 6000 V Signal: < 15 m Power: < 5 m > 50

Data according to VDE 0110/EN 61984, Clause 6.19.2.2 Degree of pollution 3 Over-voltage category III Max. height of operation 2000 m

Metal construction, EMC shielding

MAT0179626

C2/C3

Order no. 8 pin

MAT0179627

C3

Used materials Housing Zinc die-casting/brass, nickel-plated Insulation insert PBT, UL 94/V0 Seals FPM

Connection nut Brass, nickel-plated Contacts Brass, gold-plated Clamping ring Brass,nickel-plated

Order no. 9 pin

MAT0179628

C9

Housing with SpeedTEC quick-release fastener

+ 460

4 pin 2,5mm2: 20 A 630 V (AC /DC) 6000 V < 5 m > 50

51147 Cologne, Germany

Power extension 9 pin, nickel-plated Order no.

Max. rated current Rated voltage Test voltage (L-L) Resistance Insertion cycles

Fax +49(0)2203/9649-222

Clamping area: 9.5-14.5 mm

info@igus.de

4 x crimping contact 2.0 mm, crimp area: 0.35-2.5 mm2 4 x crimping contact 1.0 mm, crimp area: 0.14-1.0 mm2

igus® GmbH

E-Type 8-pin

3,6 A 63 V (AC /DC) 1500 V < 15 m > 50

www.igus.eu

Power extension 8 pin, nickel-plated Order no.

Max. rated current Rated voltage Test voltage (L-L) Resistance Insertion cycles

Tel. +49(0)2203/9649-800

Electrical data signal 17 pin

Page 469

Housing with SpeedTEC quick-release fastener

www.igus.eu/quickpin ®

Page 469

... no minimum order quantity

®

igus QuickPin – Configure readycable online

461


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:19 Seite 462

igus® connectors SERIES M17

SERIES M17

Signal-und Power connector M17 signal [17-pin] and power connector [4 to 9-pin]

Signal-und Power connector M17 signal [17-pin] and power connector [4 to 9-pin]

Signal plug 17 pin, nickel-plated Order no.

Signal extension 17 pin, nickel-plated Order no.

P-Type 4-pin

Crown clamp, Female crimping 0,5 mm, slitted crimp area: 0.35-2.5 mm2 clamping area: 9.5-12.0 mm

MAT0179641

Power plug 7 pin, nickel-plated Order no.

C6

P-Type 7-pin

HC-female crimping 1.0 mm, Crimp area: 0.5-1.5 mm2

Crown clamp, clamping area: 9.5-12.0 mm

MAT0179643

INTERCONTEC

Power plug 9 pin, nickel-plated Order no.

C1

P-Type 9-pin

4 x HC-female crimping 1.0 mm, Crown clamp, Crimp area: 0.5-1.5 mm2 clamping area: 5 x female crimping 0.6 m, 9.5-12.0 mm slitted crimp area: 0.14-0.5 mm2

MAT0179645

C1+B

Housing with SpeedTEC quick-release fastener

+ 462

Page 469

Crimping contact 0,5 mm, crimp area: 0.35-2.5 mm2

Crown clamp, clamping area: 9.5-12.0 mm

Metal construction, EMC shielding

C6

E-Type 7-pin

Crimping contact 1,0 mm, crimp area: 0.5-1.5 mm2

Crown clamp, clamping area: 9.5-12.0 mm

Metal construction, EMC shielding

C1

E-Type 9-pin

4 x crimping contact 1.0 mm, Crimp area: 0.5-1.5 mm2 5 x crimping contact 0.6 mm Crimp area: 0.14-0.5 mm2

Crown clamp, clamping area: 9.5-12.0 mm

MAT0179646

Housing with SpeedTEC quick-release fastener

www.igus.eu/quickpin ®

E-Type 4-pin

MAT0179644

Power extension 9 pin, nickel-plated Order no.

Metal construction, EMC shielding

B

MAT0179642

Power extension 7 pin, nickel-plated Order no.

Metal construction, EMC shielding

Metal construction, EMC shielding

MAT0179640

Power extension 4 pin, nickel-plated Order no.

Metal construction, EMC shielding

Crown clamp, clamping area: 9.5-12.0 mm

Fax +49(0)2203/9649-222

Power plug 4 pin, nickel-plated Order no.

B

Crimping contact 0.6 mm, crimp area: 0.14-0.5 mm2

Metal construction, EMC shielding

C1+B

Page 469

... no minimum order quantity

51147 Cologne, Germany

MAT0179639

E-Type 17-pin

info@igus.de

Metal construction, EMC shielding

Tel. +49(0)2203/9649-800

Crown clamp, Female crimping 0.6 mm, slitted crimp area: 0.14-0.5 mm2 clamping area: 9.5-12.0 mm

igus® GmbH

P-Type 17-pin

Connector

according to Intercontec standard

www.igus.eu

SERIES M17

®

igus QuickPin – Configure readycable online

463


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:20 Seite 464

SERIES C

igus® connectors SERIES C

SERIES C

according to Intercontec standard Power connector Size 1,5 [6, 8 and 9-pin] ● Connector, angular connector

● Installation box straight with flange

● Extension

● Installation box angled and turnable flexed with flange

● Lead-through

Power plug 8 pin, nickel-plated Order no.

P-Type 8-pin

4 x HC-female crimping 3.6 mm, Clamping area: crimp area: 1.5-10.0 mm2 9.0-16.5 mm 4 x HC-female crimping 2.0 mm, crimp area: 0.5-2.5 mm2

MAT0179630

Metal construction, EMC shielding

D9+C2

Number of contacts

Connector

Types

● 6, 8, 9

Technical data of the SERIES C -20 °C to 130 °C IP 66/67 [plugged]

Electrical data power contacts Max. rated current Rated voltage Test voltage (L-L) Resistance Insertion cycles

75 A 630 V (AC/DC) 6000 V < 1 m > 50

P-Type 9-pin

4 x HC-female crimping 3.6 mm, Clamping area: crimp area: 1.5-10.0 mm2 9.0-16.5 mm 5 x HC-female crimping 2.0 mm, crimp area: 0.5-2.5 mm2

MAT0179631

Metal construction, EMC shielding

D9+C2

Electrical data signal contacts Max. rated current Rated voltage Test voltage (L-L) Resistance Insertion cycles

30 A 630 V (AC/DC) 4000 V < 3 m > 50

Power extension 6 pin, nickel-plated Order no.

E-Type 6-pin

4 x crimping contact 3.6 mm, crimp area: 1.5-10.0 mm2 2 x crimping contact 2.0 mm, crimp area: 0.5-2.5 mm2

Clamping area: 9.0-16.5 mm

MAT0179632

Metal construction, EMC shielding

D9+C3

Data according to VDE 0110/EN 61984, Clause 6.19.2.2

Fax +49(0)2203/9649-222

Power plug 9 pin, nickel-plated Order no.

Tel. +49(0)2203/9649-800

Temperature range Protection class

Degree of pollution 3 Over-voltage category III Max. height of operation 2000 m

Metal construction, EMC shielding

D9+C2

www.igus.eu/quickpin ®

4 x crimping contact 3.6 mm, crimp area: 1.5-10.0 mm2 4 x crimping contact 2.0 mm, crimp area: 0.5-2.5 mm2

Clamping area: 9.0-16.5 mm

Power extension 9 pin, nickel-plated Order no.

51147 Cologne, Germany

4 x HC-female crimping 3.6 mm, Clamping area: crimp area: 1.5-10.0 mm2 9,0-16,5 mm 2 x HC-female crimping 2.0 mm, crimp area: 0.5-2.5 mm2

E-Type 8-pin

MAT0179633

MAT0179629

+ 464

P-Type 6-pin

Power extension 8 pin, nickel-plated Order no.

info@igus.de

Power plug 6 pin, nickel-plated Order no.

Magnesium die-casting/Aluminum Brass, nickel-plated PA 6.6/PBT, UL 94/V0 Brass, gold-plated FPM/HNBR Brass, nickel-plated

igus® GmbH

INTERCONTEC

Housing Connection nut Insulation insert Contacts Seals Clamping ring

www.igus.eu

Used materials Metal construction, EMC shielding

D9+C3

E-Type 9-pin

4 x crimping contact 3.6 mm, crimp area: 1.5-10.0 mm2 5 x crimping contact 2.0 mm, crimp area: 0.5-2.5 mm2

Clamping area: 9.0-16.5 mm

MAT0179634

... no minimum order quantity

Metal construction, EMC shielding

D9+C3

®

igus QuickPin – Configure readycable online

465


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:20 Seite 466

SERIES D

igus® connectors SERIES D

SERIES D

according to Intercontec standard Power connector Size 3 [6 und 8-pin] ● Connector

● Installation box straight with flange

● Extension

● Installation box angled with flange

Power plug 6 pin, nickel-plated Order no.

Number of contacts

P-Type 6-pin

● 6, 8

Crown clamp, clamping area: 17.0-36.0 mm

Metal construction, EMC shielding

MAT0179635

Technical data of the SERIES C Temperature range Protection class

Power: 4 x female crimping 10.0 mm, crimping range: 10.0 mm2/AWG8 Signal: 2 x female crimping 1.6 mm, crimping range: 0,5 mm2

Connector

Types

E10+C7

-20 °C to 130 °C IP 66/67 [plugged]

Electrical data power contacts

12 A 250 V (AC/DC) 4000 V < 5 m > 50

Metal construction, EMC shielding

MAT0179636

E10+C7

Data according to VDE 0110/EN 61984, Clause 6.19.2.2 Degree of pollution 3 Over-voltage category III Max. height of operation 2000 m

Power extension 6 pin, nickel-plated Order no.

E-Type 6-pin

Used materials Zink die-casting, nickel-plated Brass, nickel-plated PA 6.6/PBT, UL 94/V0 Brass, silver-/gold-plated FPM Aluminium, nickel-plated

Power extension 8 pin, nickel-plated Order no.

Metal construction, EMC shielding

E10+C8

E-Type 8-pin

Power: 4 x crimping contact 10.0 mm crimping range: 10.0 mm2/AWG8 Signal: 4 x crimping contact 1.6 mm crimping range: 0,5 mm2

Crown clamp clamping area: 17.0-36.0 mm

MAT0179638

+ 466

Crown clamp, clamping area: 17.0-36.0 mm

MAT0179637

INTERCONTEC

Housing Connection nut Insulation insert Contacts Seals Clamping ring

Power: 4 x crimping contact 10.0 mm crimping range: 10.0 mm2/AWG8 Signal: 2 x crimping contact 1.6 mm crimping range: 0,5 mm2

www.igus.eu/quickpin ®

... no minimum order quantity

Fax +49(0)2203/9649-222

Max. rated current Rated voltage Test voltage (L-L) Resistance Insertion cycles

Crown clamp, clamping area: 17.0-36.0 mm

51147 Cologne, Germany

Electrical data signal contacts

Power: 4 x female crimping 10.0 mm, crimping range: 10.0 mm2/AWG8 Signal: 4 x female crimping 1.6 mm, crimping range: 0,5 mm2

info@igus.de

P-Type 8-pin

Tel. +49(0)2203/9649-800

Power plug 8 pin, nickel-plated Order no.

igus® GmbH

max. 150 A 630 V (AC/DC) 6000 V < 90 m > 50

www.igus.eu

Max. rated current Rated voltage Test voltage (L-L) Resistance Insertion cycles

Metal construction, EMC shielding

E10+C8

®

igus QuickPin – Configure readycable online

467


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:21 Seite 468

SERIES S

igus® connectors SERIES S

SERIES S

according to Intercontec standard Power connector Single-pin Types Power extension 1 pin, nickel-plated

● Extension

Number of contacts

E-Type 1-pin

Crimping contact 8.0 mm, crimping range: 10.0 mm2

Crown clamp, clamping area: 9.5-14.5 mm

Metal construction, EMC shielding

MAT0179670

E10

● 1

Connector

● Installation box straight with flange

● Connector

Technical data of the SERIES S -20 °C to 130 °C IP 66/67 [plugged] Power installation box straight, E-Type long, 1 pin, nickel-plated 1-pin On request

Electrical data of the SERIES S Rated voltage 630 V (AC/DC) Test voltage (L-L) 8000 V Resistance < 110 m Insertion cycles > 50 Max. rated current for crimping range 10 mm2: 80 A for crimping range 16 mm2: 100 A for crimping range 25 mm2: 130 A for crimping range 35 mm2: 160 A for crimping range 50 mm2: 200 A

Crown clamp: Not necessary

Metal construction, axial seal

The quick-release fastener SpeedTEC is available for the types plugs, extensions, straight mounting boxes and angled mounting boxes from the series A, B, C and M17.

Degree of pollution 3 [2] Over-voltage category IV Max. height of operation 2000 m

Used materials

Power plug 1 pin, nickel-plated On request

Female crimping 8.0 mm, crimping range: 10.0 mm2

Crown clamp, clamping area: 9.5-14.5 mm

However, the type SpeedTEC plug housing can only be connected with other SpeedTEC types.

Metal construction, EMC shielding

MAT0179669

+ 468

P-Type 1-pin

E10

www.igus.eu/quickpin ®

51147 Cologne, Germany

SpeedTEC extensions and installation boxes are compatible with the available screw solutions.

info@igus.de

INTERCONTEC

Please note:

igus® GmbH

The SpeedTEC connectors are sealed according to IP67 and conform to national and international certifications, including VDE, UL/CSA and CCC.

Zinc die-casting/brass, nickel-plated Brass, nickel-plated PA 6.6mod., UL 94/V0 Brass, silver-plated FPM Brass, nickel-plated

Fax +49(0)2203/9649-222

Connector – quick release fastener

Tel. +49(0)2203/9649-800

E10

Data according to VDE 0110/EN 61984, Clause 6.19.2.2

Housing Connection nut Insulation insert Contacts Seals Clamping ring

Crimping contact 8.0 mm, crimping range: 10.0 mm2

www.igus.eu

Temperature range Protection class

... no minimum order quantity

®

igus QuickPin – Configure readycable online

469


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:22 Seite 470

Tools Accessories

Tools Accessories

igus tools, accessories ®

according to Intercontec standard Crimping tool for SERIES C 9

D Hand crimping tool for Ø 1 mm contacts till core cross section 1 mm2 complete with positioning insert On request

A

Positioning insert for Ø 0.6 mm contacts

Positioning insert for Ø 3.6 mm contacts

On request

MAT0179194

Connector

Crimping tool for SERIES A and B

Hand crimping tool for Ø 3.6 mm contacts till core cross section 16 mm2 inclusive positioning carrier On request

MAT0179195

Crimping tool for SERIES C On request

MAT01710294

MAT0179467 Pneumatic crimping tool for Ø 3.6 mm and Ø 2.0 mm contacts Core cross section 1.5-16 mm2 On request

Crimping tool for SERIES M17

Hand crimping tool for Ø 0.6 mm contacts till core cross section 0,5mm2 complete with positioning insert On request

B

Crimping insert for pneumatic crimping tool

4-thorn crimping tool for Ø 0,14mm2 to 6.0mm2 contacts

Contact

delivered with locator On request

Crimp area On request

Pin Ø 2.0 mm Bush Ø 3.6 mm 1.5/2.5 mm2 1.5/2.5 mm2 On request

Pin Ø 3.6 mm Bush Ø 3.6 mm 4.0/6.0 mm2

Pin Ø 3.6 mm Bush Ø 3.6 mm 10.0 mm2

Pin Ø 3.6 mm Bush Ø 3.6 mm 16.0 mm2

On request

On request

On request

MAT01713970

Locator for pneumatic crimping tool

Fax +49(0)2203/9649-222

Alternative crimping tool for A or C

Tel. +49(0)2203/9649-800

MAT0178919

Crimping tool for SERIES A, B, C, D and M17

51147 Cologne, Germany info@igus.de

3

igus® GmbH

2

www.igus.eu

1

C

INTERCONTEC

Contact Hand crimping tool for Ø 1 mm contacts and Ø 2 mm contacts to core cross section 4 mm2 inclusive positioning carrier On request

Positioning insert for Ø 1 mm contacts

Positioning insert for Ø 2 mm contacts

Positioning insert for Ø 1 mm and Ø 2 mm contacts

On request

On request

On request

MAT0175736

MAT0178195

MAT0178196

MAT0177855

4

E

Positioning insert for Ø 2 mm contacts

Positioning insert for Ø 0,5 mm contacts

Positioning insert for Ø 0.5-2.5 mm Contacts

Positioning insert for Ø 1.6 mm contacts

Positioning insert for Ø 1.6 mm contacts

Battery-powered crimping tool, B131-C

On request

On request

On request

On request

On request

On request

MAT01714574

MAT0178920

MAT0177853

MAT01714575

MAT01714573

470

On request

Pin Ø 3.6 mm Bush Ø 3.6 mm 1.5-10.0 mm2

Pin Ø 3.6 mm Bush Ø 3.6 mm 1.5-16.0 mm2

On request

On request

Crimping insert for SERIES S and D 8

7

6

5

Crimp area

Pin Ø 2.0 mm Bush Ø 2.0 mm 1.5/2.5 mm2 1.5/2.5 mm2 On request

MAT0177854

10

11

12

13

Crimping insert Crimping insert up to 10 mm2, 16 mm2 up to 25 mm2

Crimping insert up to 35 mm2

Crimping insert up to 50 mm2

On request

On request

On request

On request

MAT01713679

MAT01713678

MAT01713677

MAT01713676

471


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:22 Seite 472

SUB-D

igus® Connectors SUB-D

SUB-D

according to FTC standard Signal connector SUB-D standard [9 to 44-pin] ● Connector, standard- and angular connector

Size 1 9-pin - HD15-pin Order no.

Number of contacts

Solder contact Pin 9-pin standard

Metal hood, straight

Solder contact Socket 9-pin standard

Metal hood, straight

Solder contact Pin HighDensity 15-pin

Metal hood, straight

Solder contact Socket HighDensity 15-pin

Metal hood, straight

Solder contact Pin 9-pin standard

Metal hood, angled

Solder contact Socket 9-pin standard

Metal hood, angled

Solder contact Pin HighDensity 15-pin

Metal hood, angled

Solder contact Socket HighDensity 15-pin

Metal hood, angled

MAT01716504

● Standard 9, 15, 25 ● High Density 15, 26, 44 Size 1 9-pin - HD15-pin Order no.

Technical data Temperature range

-35 °C to 100 °C

Connector

Types

MAT01716505

Resistance

1016  /cm

MAT01716506

Insertion cycles

50

Used materials Zinc die-casting, nickel-plated

Size 1 9-pin - HD15-pin Order no.

Insulation insert

Glass fibre reinforced polyester

MAT01716507

Contacts

Copper alloy, gold-plated

Housing

Size 1 9-pin - HD15-pin Order no.

Fax +49(0)2203/9649-222

Size 1 9-pin - HD15-pin Order no.

51147 Cologne, Germany

(L-L) 1200 V

info@igus.de

Test voltage

Tel. +49(0)2203/9649-800

5A

igus® GmbH

Max. rated current

www.igus.eu

Electrical data

MAT01716508

Size 1 9-pin - HD15-pin Order no.

MAT01716509

Size 1 9-pin - HD15-pin Order no.

FCT

MAT01716510

Size 1 9-pin - HD15-pin Order no.

MAT01716511

+ 472

www.igus.eu/quickpin ®

... no minimum order quantity

®

igus QuickPin – Configure readycable online

473


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:22 Seite 474

SUB-D

igus® Connectors SUB-D

SUB-D

Solder contact Pin 15-pin standard

Metal hood, straight

MAT01716512

Solder contact Socket 15-pin standard

Metal hood, straight

Solder contact Pin HighDensity 26-pin

Metal hood, straight

Size 3 25-pin - HD44-pin Order no.

Solder contact Socket HighDensity 44-pin

Metal hood, straight

Metal hood, angled

Size 3 25-pin - HD44-pin Order no.

Solder contact Pin 25-pin standard

Metal hood, angled

Solder contact Socket 25-pin standard

Metal hood, angled

Solder contact Pin HighDensity 44-pin

Metal hood, angled

Solder contact Socket HighDensity 44-pin

Metal hood, angled

Fax +49(0)2203/9649-222

FCT

Metal hood, straight

51147 Cologne, Germany

Solder contact Pin 15-pin standard

MAT01716524

Solder contact Socket 15-pin standard

Metal hood, angled

Size 3 25-pin - HD44-pin Order no.

MAT01716525

Solder contact Pin HighDensity 26-pin

Metal hood, angled

Size 3 25-pin - HD44-pin Order no.

MAT01716526

Solder contact Socket HighDensity 26-pin

Metal hood, angled

MAT01716519

+ 474

Solder contact Pin HighDensity 44-pin

MAT01716523

MAT01716518

Size 2 15-pin - HD26-pin Order no.

Size 3 25-pin - HD44-pin Order no.

info@igus.de

Metal hood, straight

MAT01716517

Size 2 15-pin - HD26-pin Order no.

Metal hood, straight

Tel. +49(0)2203/9649-800

Solder contact Socket HighDensity 26-pin

MAT01716516

Size 2 15-pin - HD26-pin Order no.

Solder contact Socket 25-pin standard

MAT01716522

MAT01716515

Size 2 15-pin - HD26-pin Order no.

Size 3 25-pin - HD44-pin Order no.

MAT01716521

MAT01716514

Size 2 15-pin - HD26-pin Order no.

Metal hood, straight

MAT01716520

MAT01716513

Size 2 15-pin - HD26-pin Order no.

Solder contact Pin 25-pin standard

igus® GmbH

Size 2 15-pin - HD26-pin Order no.

Size 3 25-pin - HD44-pin Order no.

www.igus.eu

Size 2 15-pin - HD26-pin Order no.

Connector

according to FTC standard

Size 3 25-pin - HD44-pin Order no.

MAT01716527

www.igus.eu/quickpin ®

... no minimum order quantity

®

igus QuickPin – Configure readycable online

475


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:23 Seite 476

Y-CONKIT

Y-CONKIT

igus® Connectors | Yamaichi Y-CONKIT Technical data Temperature range

-20 °C to +120 °C

Electrical data Max. rated current Insertion cycles

2,1 A (70 °C), power contacts 1.000

Delivery program Yamaichi Y-CONKIT Delivery program

®

Number of poles

igus

Delivery program Yamaichi Y-CONKIT accessories Protection class

Delivery program

Part No.

®

igus

Part No.

Housing PA66

Crimping tool

Y-CONKIT 10

MAT01719769

4 (Ethernet)

IP20

Y-CONKIT 11

MAT0176641

4 (Ethernet) + 2 (Power)

IP20

Y-ConTool-11

MAT0176447

Cable dismantle tool Housing Zinc die-casting

MAT01719767

Y-CONKIT 17

MAT01719770

4 (Ethernet)

IP20

Y-CONKIT 15

MAT01719236

4 (Ethernet) + 2 (Power)

IP20

Housing Plastic PBT, UL94V-0

Assembling aid Y-ConTool-30

Y-CONKIT 20

MAT01719771

4 (Ethernet)

IP67/68/69K

Y-CONKIT 21

MAT0176759

4 (Ethernet) + 2 (Power)

IP67/68/69K

Y-CONKIT 40

MAT01719772

4 (Ethernet)

IP67/68/69K

Y-CONKIT 40-E

MAT01719773

4 (Ethernet)

IP67/68/69K

Y-CONKIT 41

MAT01717218

4 (Ethernet) + 2 (Power)

IP67/68/69K

Y-CONKIT 41-E

MAT01718801

4 (Ethernet) + 2 (Power)

IP67/68/69K

MAT01717349

Housing Zinc die-casting

950 types from stock no cutting costs ... 476

(for up to 10 cuts of the same type)

igus® QuickPin – Configure readycable® online www.igus.eu/quickpin

+

+

igus® QuickPin – Configure readycable® online www.igus.eu/quickpin

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

477


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:23 Seite 478

igus® Cable glands HSK-K

K-Counter nuts

Material Shaped packing Protection class

Material Continuous operating temperature

PA V0 according to UL 94 NBR IP 68-10 bar / IP 69K within the specified clamping range only with optional O-Ring

Continuous operating temperature Colour

SERIES HSK-K

SB / PA -20 °C-40 °C (SB) -40 °C-100 °C (PA) gray RAL 7035

Colour

-40 °C-100 °C gray RAL 7035

AG

Cable glands

SERIES HSK-K

Part No. gray

3 - 6.5 2-5 4-8 2-6 5 - 10 6 - 12 5-9 10 - 14 13 - 18 9 - 16 18 - 25 13 - 20 22 - 32 20 - 26 32 - 38 25 - 31 37 - 44 29 - 35

8 8 8 8 8 9 9 9 11 11 11 11 13 13 13 13 14 14

21 21 22 22 25 27 27 28 31 31 39 39 48 48 49 49 49 49

15 15 19 19 22 24 24 27 33 33 42 42 53 53 60 60 65 / 68 65 / 68

5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5

1.209.1200.50 1.209.1200.51 1.209.1600.50 1.209.1600.51 1.219.1600.50 1.209.2000.50 1.209.2000.51 1.219.2000.50 1.209.2500.50 1.209.2500.51 1.209.3200.50 1.209.3200.51 1.209.4000.50 1.209.4000.51 1.209.5000.50 1.209.5000.51 1.209.6300.50 1.209.6300.51

MAT0179492 MAT01712319 MAT0179493 MAT01712320 MAT01712321 MAT0179494 MAT01712322 MAT0179563 MAT0179495 MAT01712323 MAT0179496 MAT01712324 MAT0179497 MAT01712325 MAT0179498 MAT01712326 MAT0179499 MAT01712327

IG

M 12 x 1,5 M 16 x 1,5 M 20 x 1,5 M 25 x 1,5 M 32 x 1,5 M 40 x 1,5 M 50 x 1,5 M 63 x 1,5

H mm

Pack Size

Part No.

Order No.

mm

5 5 6 7 7 7 8 8

17 22 27 36 41 50 60 75

5 5 5 5 5 5 5 5

1.262.1200.50 1.262.1600.50 1.262.2000.50 1.262.2500.50 1.262.3200.50 1.262.4000.50 1.262.5000.50 1.262.6300.50

MAT0179500 MAT0179501 MAT0179502 MAT0179503 MAT0179504 MAT0179505 MAT0179506 MAT0179507 Request your personal savings offer. Fax: +49(0)2203/9649-222

INTERCONTEC

Request your personal savings offer. Fax: +49(0)2203/9649-222

cable diameters in mm 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45

M 12 M 16 M 20 M 25 M 32 M 40 M 50 M 63

478

Fax +49(0)2203/9649-222

Pack Size

51147 Cologne, Germany

mm

info@igus.de

H mm

Tel. +49(0)2203/9649-800

M 12 x 1,5 M 12 x 1,5 M 16 x 1,5 M 16 x 1,5 M 16 x 1,5 M 20 x 1,5 M 20 x 1,5 M 20 x 1,5 M 25 x 1,5 M 25 x 1,5 M 32 x 1,5 M 32 x 1,5 M 40 x 1,5 M 40 x 1,5 M 50 x 1,5 M 50 x 1,5 M 63 x 1,5 M 63 x 1,5

GL mm

Order No.

mm

igus® GmbH

AG

GL

www.igus.eu

H

... no minimum order quantity

479


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:23 Seite 480

igus® Cable glands HSK-M

M-Counter nuts

Material Clamping insert Shaped packing O-Ring Protection class

Material

Brass, nickel-plated PA NBR NBR IP 68-10 bar / IP 69K within the specified clamping range only

Brass, nickel-plated

AG

Cable glands

-40 °C-100 °C

mm

Pack Size

Part No. gray

3 - 6.5 2-5 4-8 2-6 5 - 10 6 - 12 5-9 10 - 14 13 - 18 9 - 16 18 - 25 13 - 20 22 - 32 20 - 26 32 - 38 25 - 31 37 - 44 29 - 35

6.5 6.5 6 6 6 6 6 6 7 7 8 8 8 8 9 9 10 10

19 19 21 21 22 23 23 24 26 26 31 31 37 37 37 37 38 38

14 14 17 / 19 17 / 19 20 22 22 24 30 30 40 40 50 50 57 57 64 / 68 64 / 68

5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5

1.609.1200.50 1.609.1200.51 1.609.1600.50 1.609.1600.51 1.609.1611.50 1.609.2000.50 1.609.2000.51 1.609.2016.50 1.609.2500.50 1.609.2500.51 1.609.3200.50 1.609.3200.51 1.609.4000.50 1.609.4000.51 1.609.5000.50 1.609.5000.51 1.609.6300.50 1.609.6300.51

MAT0179476 MAT01712328 MAT0179477 MAT01712329 MAT01712330 MAT0179478 MAT01712331 MAT0179562 MAT0179479 MAT01711769 MAT0179480 MAT01712332 MAT0179481 MAT01712333 MAT0179482 MAT01712334 MAT0179483 MAT01712335

IG

M 12 x 1,5 M 16 x 1,5 M 20 x 1,5 M 25 x 1,5 M 32 x 1,5 M 40 x 1,5 M 50 x 1,5 M 63 x 1,5

H mm

Pack Size

Part No.

Order No.

mm

2,8 2,8 3,0 3,5 4,0 4,5 5,5 6,0

15 19 23 29 36 45 55 70

5 5 5 5 5 5 5 5

1.161.1200.50 1.161.1600.50 1.161.2000.50 1.161.2500.50 1.161.3200.50 1.161.4000.50 1.161.5000.50 1.161.6300.50

MAT0179484 MAT0179485 MAT0179486 MAT0179487 MAT0179488 MAT0179489 MAT0179490 MAT0179491 Request your personal savings offer. Fax: +49(0)2203/9649-222

INTERCONTEC

Request your personal savings offer. Fax: +49(0)2203/9649-222

cable diameters in mm 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45

M 12 M 16 M 20 M 25 M 32

... no minimum order quantity

M 40 M 50

480

Fax +49(0)2203/9649-222

H mm

51147 Cologne, Germany

M 12 x 1,5 M 12 x 1,5 M 16 x 1,5 M 16 x 1,5 M 16 x 1,5 M 20 x 1,5 M 20 x 1,5 M 20 x 1,5 M 25 x 1,5 M 25 x 1,5 M 32 x 1,5 M 32 x 1,5 M 40 x 1,5 M 40 x 1,5 M 50 x 1,5 M 50 x 1,5 M 63 x 1,5 M 63 x 1,5

GL mm

Order No.

mm

info@igus.de

AG

GL

Tel. +49(0)2203/9649-800

H

igus® GmbH

Continuous operating temperature

SERIES HSK-M

www.igus.eu

SERIES HSK-M

M 63

481


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:23 Seite 482

igus Cable glands HSK-M-EMV

HSK-EMV-Industry standard

®

Material

Brass, nickel-plated

Clamping insert

PA

Shaped packing

NBR

O-Ring

NBR

Protection class

IP 68-10 bar / IP 69K

Flexible overlapping clamping splines prevent the form seal from being pulled out of the fitting. AG

-40 °C-100 °C

H

AG

M 12 x 1,5 M 12 x 1,5 M 16 x 1,5 M 16 x 1,5 M 20 x 1,5 M 20 x 1,5 M 25 x 1,5 M 25 x 1,5 M 32 x 1,5 M 32 x 1,5 M 40 x 1,5 M 40 x 1,5 M 50 x 1,5 M 50 x 1,5 M 63 x 1,5 M 63 x 1,5

mm

GL mm

H mm

3 - 6.5 2-5 5 - 10 3-7 10 - 14 7 - 12 13 - 18 9 - 16 18 - 25 13 - 20 22 - 32 20 - 26 32 - 38 25 - 31 37 - 44 29 - 35

6.5 6.5 6 6 6 6 7 7 8 8 8 8 9 9 10 10

19 19 22 22 23 23 24 24 31 31 37 37 37 37 38 38

Part No. gray

Order No.

mm

Pack Size

14 14 20 20 24 24 30 30 40 40 50 50 57 57 64 / 68 64 / 68

5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5

1.691.1200.50 1.691.1200.51 1.691.1600.50 1.691.1600.51 1.691.2000.50 1.691.2000.51 1.691.2500.50 1.691.2500.51 1.691.3200.50 1.691.3200.51 1.691.4000.50 1.691.4000.51 1.691.5000.50 1.691.5000.51 1.691.6300.50 1.691.6300.51

MAT0179508 MAT01712336 MAT0179509 MAT01712337 MAT0179510 MAT01712338 MAT0179511 MAT01712339 MAT0179512 MAT01712340 MAT0179513 MAT01712341 MAT0179514 MAT01712342 MAT0179515 MAT01712343

GL

The internal sealing edge results in a superior seal between the splined Nylon clamping insert and the nickel plated brass body.

Patented 360° grounding due to the internal O-Ring, which results in a perfect contact between braided shield of cable and fitting.

HSK-M-EMV-D Flexible overlapping clamping splines prevent the form seal from being pulled out of the fitting.

51147 Cologne, Germany info@igus.de

cable diameters in mm 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45

Flexible contact points allow contact with variable braid diameters.

M 12 M 16 M 20 M 25 M 32

... no minimum order quantity

M 40 M 50

482

igus® GmbH

INTERCONTEC

Metalized spline insert provides electrical conductivity.

www.igus.eu

Request your personal savings offer. Fax: +49(0)2203/9649-222

Fax +49(0)2203/9649-222

Continuous operating

Cable glands

HSK-M-EMV

within the specified clamping range only temperature

SERIES HSK-MEMV-D

Tel. +49(0)2203/9649-800

SERIES HSK-MEMV

M 63

483


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:24 Seite 484

igus Cable glands HSK-M-EMV-D

EMV-Counter nuts

Material Clamping insert Shaped packing O-Ring Protection class

Material

®

Brass, nickel-plated Metal coated PA NBR NBR IP 68-10 bar / IP 69K within the specified clamping range only

Brass, nickel-plated

-40 °C-100 °C

AG

Continuous operating temperature

SERIES HSK-MEMV-D

Cable glands

SERIES HSK-MEMV-D

H

IG

3 - 6.5 5 - 10 10 - 14 13 - 18 18 - 25 24 - 32 32 - 38 37 - 44

6.5 6 6 7 8 8 9 10

25 32 33 39 45 51 57,5 52

14 20 24 30 40 50 57 64 / 68

5 5 5 5 5 5 5 5

1.631.1200.50 1.631.1600.50 1.631.2000.50 1.631.2500.50 1.631.3200.50 1.631.4000.50 1.631.5000.50 1.631.6300.50

MAT0179524 MAT0179525 MAT0179526 MAT0179527 MAT0179528 MAT0179529 MAT0179530 MAT0179531

IG

M 12 x 1,5 M 16 x 1,5 M 20 x 1,5 M 25 x 1,5 M 32 x 1,5 M 40 x 1,5 M 50 x 1,5 M 63 x 1,5

INTERCONTEC

Request your personal savings offer. Fax: +49(0)2203/9649-222

H mm

mm

2.8 2.8 3.0 3.5 4.5 5.0 5.0 6.0

15 19 24 30 36 46 60 70

S Pack mm Size 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7

5 5 5 5 5 5 5 5

Part No.

1.167.1200.50 1.167.1600.50 1.167.2000.50 1.167.2500.50 1.167.3200.50 1.167.4000.50 1.167,5000.50 1.167.6300.50

Order No.

MAT0179516 MAT0179517 MAT0179518 MAT0179519 MAT0179520 MAT0179521 MAT0179522 MAT0179523

Request your personal savings offer. Fax: +49(0)2203/9649-222

cable diameters in mm 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45

M 12 M 16 M 20 M 25 M 32

... no minimum order quantity

M 40 M 50

484

Fax +49(0)2203/9649-222

Part No. gray

51147 Cologne, Germany

Pack Size

info@igus.de

mm

Tel. +49(0)2203/9649-800

H mm

igus® GmbH

M 12 x 1,5 M 16 x 1,5 M 20 x 1,5 M 25 x 1,5 M 32 x 1,5 M 40 x 1,5 M 50 x 1,5 M 63 x 1,5

GL mm

Order No.

mm

www.igus.eu

AG

GL

S

H

M 63

485


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:24 Seite 486

Strain Relief

VAKAT


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:24 Seite 488

494

496 497 498 499 500

500 500

502

502 503 502 504

504 504 505 505 506

506 507 508

508

510

510 510 511

511 512

488

489


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:25 Seite 490

490

491


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:25 Seite 492

492

493


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:25 Seite 494

494

495


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:26 Seite 496

500

496

500

497


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:26 Seite 498

498

499


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:26 Seite 500

492/493

500

501


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:27 Seite 502

502

503


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:27 Seite 504

504

505


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:27 Seite 506

506

507


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:28 Seite 508

508

509


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:28 Seite 510

510

511


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:29 Seite 512

512

513


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:29 Seite 514

readychain

VAKAT


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:29 Seite 516

igus® ready chain®

readychain® | We do it immediately

... for your capacity increase

igus® ready chain®

readychain® | Quickly increase cash flow You determine the degree of harnessing Any degree of harnessing is possible We harness from simple energy chain systems® with inserted chainflex® cables to complex systems. These systems may include all cables and hoses (pneumatic, hydraulic), patch plugs, inner partitions, connecting elements and connecting parts as requested.

From easy ..................................................................................................................... to the project

You determine the size Any size is possible Because of our up-todate production processes we can deliver fast and cheap custom-build or serial production products.

... on more than 3,000 m2

... state-of-the-art equipped... From batch size 1 ............................................................................................. to serial production

... for your Cash-flow ...

You determine the travel Choosing the travel readychains® offers the whole spectrum of possible travels of the igus® energy chains®. We harness anything from extremely short to long travels. Safe transportation guarantees damage-free delivery of all lengths.

From short ...................................................................................................................... to long travel

Standardized readychain® packages help you get started

... in the extended harnessing factory. 516

More information

www.readychain.eu

readychain® „Basic“

readychain® „Standard“

readychain® „Premium“

igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

517


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:30 Seite 518

igus® ready chain®

igus® ready chain®

readychain® | Over 100 readychain® specialists

readychain® | readycable®

Harnessed cables

Our specialists for you: Heidenhain

Allen Bradley

Jetter

B&R

Project management: (1) selecting components (2) define interfaces

Lenze

Baumüller

LTi DRiVES

Beckhoff

(3) documentation (4) continous project support (5) time schedule

NUM

Berger Lahr

customer

Project manager igus®

(6) cost optimisation

Omron

Control Techniques

Rexroth

Danaher Motion

Production: (1) trained specialists

SEW

ELAU

(2) quality assurance Fagor

Siemens

Fanuc

Stöber

(3) stock (4) standardised processes (5) transparence

readycable – in 24-48h or today ®

(6) lean management

igus® offers over 1,400 defined drive cables according to different manufacturers standards. ● Servo, power and signal/encoder cables ● No cutting costs and no surcharges for small quantities and packaging ● Cable length up to the centimeter to customer ● Smallest bending radii from 7,5 x d ● Reduce storage costs and increase cash flow

Professionally produced ...

... 100% tested

www.igus.eu/quickpin

+ 518

More information

QuickPin 2.0 Connector-Cable-Configurator with integrated EPLAN P8.

www.readychain.eu

igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

519


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:31 Seite 520

igus® ready chain®

readychain® | As unique as your project

igus® ready chain®

readychain® | In Cologne and worldwide

readychain®-factory in Cologne, Germany (ca. 3,000 m2) (orange shaded)

We invite you! Visit us in Cologne and ... ... learn more about our factory, order management, sales, planning and production.

Christian Stremlau Manager readychain® systems Tel. +49(0)2203/9649-273 E-Mail: cstremlau@igus.de

11 readychain® factories wordwide:

1 2 3

readychain factories igus® subsidiaries certified partners ®

www.igus.eu/ReadyChain/factory

520

More information

www.readychain.eu

4 5 6

igus® Cologne igus® Brasil igus® China igus® India igus® Italy igus® Japan

7 8 9 10 11

igus® South Africa igus® South Korea igus® Spain igus® UK igus® USA

igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

521


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:31 Seite 522

®

chainflex

Page

Technical Data and Schedules/user information/contact Designing with igus® Cables and Hoses – General rules for cables and hoses in energy chains® ®

524

Cables and Hoses – Separation in energy chains

525

Cables and Hoses – Further information on the separation of cables

526

Electrical Round Cables

527

Electrical Round Cables – Information on assembly and strain relief of electrical round cables

528

Pneumatic hoses

529

Designing

Data and Schedules DIN 47100 colour code/Copper wire dimensions according to Anglo-American AWG numbers

530

Calculation of the copper surcharge

530

Load-Carrying Capacity of Cables

531

Electrotechnical data

532

Chemical resistance

538

Informations The General Conditions

542

User information, Disclaimer, KTG, Product illustrations

542

Technical notes

542

Approbation and Approvals

544 ®

Configure and order cables online, igus & eplan

546

®

548

igus at www.igus.eu

549

According to industries

550

Table of contents according to part number

558

More igus products ®

Contact igus® Fax – Customer-specific cables for energy chain systems®

554

Fax – System Planning

555

Fax – Harnessing

556

Fax – Order

557

®

igus worldwide

564

Give us your oppinion – Catalogue improvement

Cover (back)

Definition of the icons used in the catalogue

Cover (back)

chainflex® cables classification What does the chainflex® "class"(ification) mean?

Cover (ahead) 20

523


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:31 Seite 524

Designing with igus®

Designing the Filling Cables and Hoses

Designing the Filling Cables and Hoses

General rules for cables and hoses in energy chains®

Separation in energy chains®

Designing with igus®

Data and energy supply in all forms – in an energy chain system®

Rules for:

● Maximum

That is the big advantage of an igus® energy chain system®: You can safely accommodate

● Cables with extremely varying diameters

cable diameter

many different forms of data cables and energy carriers in a system. It remains up to you,

should be installed so that they are sepa-

● Separation ● Bending radius

however, to decide how strictly you want to apply your rules to separating and subdividing

rated from one another. The separation is

various media. You can, for example, comply with the minimum separating distances between

provided by means of separators.

bus cables and power cables and mix any pneumatic, electrical and hydraulic systems.

● Cables must never have the possibility of being able to push themselves over one

In addition to the quality of the cables being used,

another. This is why the clear height of a

the arrangement of a cable within a chain as well

compartment with several equally thick

Complete the fax form on page

as the space conditions. Many different separa-

cables lying next to one another must

552 of the catalog – and receive

tion variants make it possible to adapt the

never amount to more than the cable

your finished project suggestion

energy chains to suit the specific requirements

diameter plus 50%.

in a few hours!

of each application. Generalized rules such as

®

D1 + D2 > 1.2 x hi

d1 + d2 ≤ 1.2 x hi

Expressed in rules, this means:

"No more than 80% of the clear space of energy

Rule 1:

chains® is allowed to be used" no longer make sense given the complexity of present-day

If D1 + D2 > 1.2 x chain inner height, no

applications. In this chapter, we will attempt

separation must be made between the two

to give you detailed recommendations. Due to

cables. Two cables should never be allowed to

the large number of application variants, we

lie on top of one another in unguided form or become tangled.

recommend that you use our free planning service in any case. Specify your requested

Hydraulic and electrical systems (in closed

cables – or also only the demanded electrical

section) are separated from one other in

Rule 2:

or other output data – and you will then receive

this example.

If d1 + d2 ≤ 1.2 x chain inner height, a sepa-

the recommendation we have worked out for

rator or a modular compartment bottom must

you.

be installed in order to reduce the inner height.

Fax form on page 552 + Internet questionnaire

This is done in order to prevent d1 and d2

at www.igus.eu or simply give us a telephone

from becoming "mixed up".

d1 + d2 ≤ 1.2 x hi

call. Within a few hours, you will be holding The reason for these rules is:

a detailed system suggestion in your hands.

The cables must be installed and fastened so that they can move freely in longitudinal direction at any time and do not exert any

Maximum cable diameter

tensile force in the radius on the energy chains®.

The maximum cable diameter corresponds to the clear height of the selected energy chains®/ energy tubes minus the reserve space. This

In case of applications with high travel velocities

Electrical cables require at least 10%

minimum reserve space, for example, amounts

and many load cycles, no cables are allowed to

of reserve space "all-round", hydrau-

to 10% for electrical round cables, and 20% for

Perfectly installed cables with igus® interior

be placed on top of one another without a

Reserve space capacities in %

lic hoses 20%

hydraulic hoses. energy chains® are ideally filled

separation

horizontal separation.

for various cables

The guidance values for these applications are:

Cables

when a lateral minimum separating distance to

Reserve space "all-round" for electrical round cables

The maximum cable diameter is specified for each series in the relevant chapter

Reserve space "all-round"

the next cable or wall is provided. Depending on the structure of the cables and the dynamics and

Travel velocity exceeding 0,5 m/s and load

Electrical round cables

10 %

the service life, extra reserve space must be

cycles exceeding 10.000 p.a.

Electrical flat cables

10 %

Pneumatics

5 -10%

filling can also be designed to meet more con-

The igus® interior separation offers a reliable

Hydraulics

20 %

fined space requirements.

solution for these applications.

Media hoses

15 - 20 %

provided in addition. In cases of exception, the

Please discuss this subject with us.

524

More information

www.chainflex.eu

igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

525


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:31 Seite 526

Designing with igus®

Designing the Filling Cables and Hoses Further information on the separation of cables

Designing the Filling Electrical Round Cables

Designing with igus®

Electrical round cables In the case of electrical cables, the round cable is a reliable, modular and low-cost solution for energy chain systems®.

● The cable weight should be distributed

For your purchase, we recommend that you consider the following criteria:

symmetrically across the width of the chain. Selection criteria:

● In the case of cables with different external

● Small minimum bending radii and mounting

jackets, it is important to make sure that

heights

they do not become "stuck together". If separately. igus chainflex cables of all

● ● Service life for your application case, e.g.

the series can be combined with one

short or long distance of travel or suspended

Service life with minimum bending radius

appropriate, they may have to be installed ®

®

installation use

another.

● The cables should always be fastened with a strain relief device at the fixed end and at the moving end. Exceptions are only to be

The igus® kit of energy chain systems® solves all the requirements for interior separation known today

Test values for the service life based on

Uncomplicated handling during assembly,

practice-oriented experiments e.g. no detaching, laying out, etc.

found in the case of some hydraulic hoses

● Strain relief device on the connection ele-

with length compensation or in the case of

Example igus® experimental laboratory: constant development and testing of chainflex® electrical round cables

ment should be possible

other high-pressure hoses. (see "Hydraulic hoses")

Bending-resistant shields in the case of

Abrasion-resistant, readily gliding external

Large selection in order to avoid expensive

shielded cables

● Generally speaking, the following applies: The faster and more frequently the energy

jackets

chains travel, the more important the ®

precise assignment of the cables in the

production of single products

chain will be. Due to the large number of variants, we will gladly advise you with your specific application.

In the case of bus cables and fibre-optic cables, it is especially important to consider how well the transmission rates and the shielding effects

Bending radius R

● The bending radius of your energy chains

igus® chainflex® cables also allow for minimum bending radii

®

of 5 x d together with millions of strokes.

are maintained after several million strokes in the minimum bending radius.

is a factor of the "thickest" or "stiffest" cable or hose in your filling.

● The bending radius of the energy chains

®

should be adapted to suit the recommendations of the cable manufacturer. The selection of bending radius greater than the minimum bending radius has a positive effect on the service life to be expected.

● The specification of minimum bending radii in the case of cables applies to service use at normal temperatures. The use of other bending radii may therefore be advisable. Please ask your cable supplier.

The igus ® product range offers up to 12 different bending radii for each chain series from stock. Here series 50 in the Storebaelt bridge project. We will be glad to give you our recommendations for a complete energy chain system®. The bending radii of all cables and hoses, interior separation and service life are then perfectly adapted to suit one another in the best possible way. Also ask us about the igus® system guarantee.

526

More information

www.chainflex.eu

Harnessing, from page 515 onwards

igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

527


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:31 Seite 528

Designing with igus®

Designing the Filling Electrical round cables Information on assembly and strain relief of electrical round cables

Correct!

1. The cables must be installed twist-free. Drums or rings are not allowed to be pulled off across the top. igus® chainflex®

Designing with igus®

Design Information Pneumatic hoses Basically, the same rules that apply to round cables also apply to pneumatic hoses. In practice, however, it can be seen that pneumatic hoses

cables are ready to be laid immediately.

are less susceptible to malfunctions. Following

They do not need to be detached or laid

proper consultation, they can also be laid to meet

out prior to the assembly procedure.

more confined space requirements than is pro-

2. The cables must be laid so that each

vided for by the "10% reserve space all-round"

individual cable can move freely in longi-

rule. A strain relief device on both sides is usually

tudinal direction.

the case here as well. In the case of pneumatic

3. The cables must be able to move freely

Wrong!

in the radius. This must be checked when the upper section reaches the biggest clear length. 4. The separation of the interior space by means of separators or by means of the

hoses made of rubber, we recommend strict compliance with the "10% reserve space" rule because these hoses tend to become "stuck together" among one another or with other

Completely ready-made energy chain

cables.

system ® with several pneumatic hoses next to and on top of one another.

igus® interior separation system is required whenever several or many cables with

The igus® product range also offers thermoplastic pneumatic hoses "chainflex® CF AIR".

different diameters are being installed.

Page 228

It is important to make sure that the cables cannot wrap themselves around

Wrong!

one another in spiral form. 5. In the case of cables with different external jackets, it is important to make sure that they do not become "stuck together". If appropriate, they may need to be separated. igus® chainflex® cables of all the series can be combined with one another. 6. Electrical round cables must be fastened in strain-relieved form on both sides. In cases of exception, the cables must at least be fastened in strain-relieved form

Cables must be able to move freely in the radius

at the moving end of the energy chains®. A separating distance of 10-30 x cable diameter is recommended for most cables. chainflex ® cables, however, can be strain-relieved directly at the connection element, as confirmed by many series of tests. We will be glad to make you an offer on our ready-made energy chain systems®: "readychain®: chain, cable, harnessing".

chainflex® cables can be strain-relieved directly at the connection element.

Harnessing, from page 515 onwards

Corkscrewing: An imperfectly matched system can result in these failures.

528

More information

www.chainflex.eu

igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

529


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:31 Seite 530

Data and Schedules

Special Cables Information Colour Code + Copper Price DIN 47100 colour code (however, deviating from DIN: without colour repetition after 44th core)* 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

white brown green yellow gray pink blue red black violet gray-pink red-blue white-green brown-green white-yellow yellow-brown

white-gray gray-brown white-pink pink-brown white-blue brown-blue white-red brown-red white-black brown-black gray-green yellow-gray pink-green yellow-pink green-blue yellow-blue

33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

49 50 51 52 53 54 55 56 57 58 59 60 61

green-red yellow-red green-black yellow-black gray-blue pink-blue gray-red pink-red gray-black pink-black blue-black red-black white-brown-black yellow-green-black gray-pink-black red-blue-black

white-green-black brown-green-black white-yellow-black yellow-brown-black white-gray-black gray-brown-black white-pink-black pink-brown-black white-blue-black brown-blue-black white-red-black brown-red-black black-white

Data and Schedules

Special Cables Information Load-Carrying Capacity of Cables The values from the tables on the side of this page have

Table 1: Cables for fixed installation in energy-conducting

been taken from the standard DIN VDE 0298, Part 4.

chains and tubes

These values have been simplified and only apply approximately. For each user, it is advisable to obtain and comply with the regulations that apply to each indi-

Insulation material chainflex® type

vidual case of application (e.g. measures for protection in case of indirect contact in accordance with DIN VDE 0100 Part 410, overcurrent protective devices in accordance with DIN VDE 0100 Part 430 or voltage drop in accordance with DIN VDE 0100 Part 520). It is not possible to provide all the regulations or overviews in this catalog. Due to the harmonization that has been carried out, it is possible that different load-carrying

PVC

TPE

CF5, CF6, CF2, CF130.UL, CF140.UL, CF211(D) CF77.UL.D, CF78.UL, CF9, CF10, CF9.UL, CF10.UL, CF98, CF99, CF240, CF211, CF112, CF113, CF11, CF12, CF211(M), CF113.D, CF111.D, CF11.D, CF210.UL, CF21.UL, CF270.UL.D, CF27.D, CF30, CF31, CF34.UL.D, CF35.UL, CF37.D, CF38, CF300.UL.D, CFPE, CF310.UL, CF330.D, CF340, CFBRAID, CFROBOT, CFROBOT 6,7,9

values may be permissible for the same cable in some cases. For the selection of the relevant cross sections,

* Exception: 4-core cables are braided in the colour sequence white, green, brown, yellow.

The first colour indicates the basic colour of the core insulation, and the second colour indicates the colour of the printed-

the load capacity in undisturbed operation is the deter-

on ring. In the case of three colours, the second and colours are printed on the basic colour.

mining factor, i.e. the use with permissible operating

Calculation of the copper surcharge

the conductor.

Number of cores

2 or 3

Installation

temperature or permissible maximum temperature on The copper index specifies the weight of the copper share in a

The copper surcharge is the calculation of the difference bet-

cable in kg/km. The product from the copper index (kg/km) and

ween the calculated price (copper basis) and the fluctuating,

the price difference per kg of copper according to the DEL quo-

The load-bearing capacity according to Table 1 on this

actual price of the copper share in a cable. In calculatory terms,

tation then provides the copper surcharge in € per km of cable.

page applies to operating-current-carrying conductors.

the list price of each chainflex® cable is based on a copper

Here, the following example:

Normally, these are 2 loaded conductors in the case

price to the amount of € 150,-/100 kg of copper. In the end,

Cable:

chainflex® CF9.15.18

of 2-core and 3-core cables, as well as 3 loaded con-

however, this copper share is calculated on the basis of the

Copper index:

260 kg/km

ductors in the case of 4-core and 5-core cables. Plea-

current daily price according to the DEL (German abbr. = Ger-

DEL quotation:

€ 189,–/100 kg Cu

se take this into account when planning for the use of

man electrolyte copper for conducting purposes) quotation.

Copper basis:

€ 150,–/100 kg Cu

multi-core cables in electrical installation conduits or energy chains®. This information is based on an ambient

Copper index [kg/km] x

DEL quotation [ €/100 kg] – Copper basis [ €/100 kg]

= Copper surcharge [€/km]

100 260 x

189 – 150

apply the conversion factors according to Table 2 in case the air temperature is increased due to the heat

= Copper surcharge [€/km]

loss of the cables (please take thermal radiation into

100

account as well, e.g. effects of exposure to the sun).

Copper surcharge = 101,40 €/km For this example, the copper surcharge amounts to € 101.40/km of cable. Any discounts that are granted only apply

The possible cable installation types in energy chains®

to the cable prices but not to the copper surcharge. The copper surcharge is shown separately on our invoices.

result in such a broad range of loading profiles that no

New: You now have the possibility of calculating the individual extra charge for copper for your cable on-line

generalized conversion factors can be mentioned for

Table 2: Conversion factors in case of varying ambient

this large accumulation of cables. The installation type

temperatures

www.igus.eu/en/cfcu

Copper wire dimensions according to Anglo-American AWG numbers AWG

530

temperature of 30°C and a non-loaded cable. Please

Nominal cross section Load-carrying capacity in amperes Nominal cross of PVC TPE copper cable in insulation insulation mm2 0,14 2,5 2,5 0,25 4 5 0,34 5 7 0,50 8 10 0,75 12 14 1 15 17 1,50 18 21 2,50 26 30 4 34 41 6 44 53 10 61 74 16 82 99 25 108 131 35 135 162 50 168 202 70 207 250 95 250 301 120 292 352 150 – 404 185 – 461

Diameter

Cross section

No.

mm

mm2

No.

500 350 250 4/0 3/0 2/0 1/0 1 2 4 6 8 10 12 14 16

17,96 15,03 12,70 11,88 10,40 9,27 8,25 7,35 6,54 5,19 4,12 3,26 2,59 2,05 1,63 1,29

253,00 177,00 127,00 107,20 85,00 67,50 53,50 42,40 33,60 21,20 13,30 8,37 5,26 3,31 2,08 1,31

18 20 22 24 26 28 30 32 34 36 38 40 42 44

More information

www.chainflex.eu

AWG

Diameter

Cross section

mm

mm2

1,024 0,813 0,643 0,511 0,405 0,320 0,255 0,203 0,160 0,127 0,102 0,079 0,064 0,051

0,823 0,519 0,324 0,205 0,128 0,0804 0,0507 0,0324 0,0200 0,0127 0,00811 0,00487 0,00317 0,00203

and the conversion factors must be looked up in Table 3 according to each individual application.

Table 3: Conversion factors for multi-core cables with cable cross sections up to 10 mm2 Loaded cores 5 7 10 14 19 24 40 61

Conversion factor 0,75 0,65 0,55 0,50 0,45 0,40 0,35 0,30

Ambient temperature °C 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90

Conversion factor PVC TPE insulation insulation 1,22 1,17 1,12 1,06 1,00 0,94 0,87 0,79 0,71 0,61 0,50 – – – – – –

1,15 1,12 1,08 1,04 1,00 0,96 0,91 0,87 0,82 0,76 0,71 0,65 0,58 0,50 0,41 0,29 0,14

igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

531


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:31 Seite 532

Data and Schedules

Special Cables Information Electrotechnical data

Special Cables Information Electrotechnical data

The following tables provide measured values on the electrotech-

The specification of the characteristic wave impedance at high fre-

nical data of the cables available at the time of the survey. The

quencies in Ω is an important quantity for a reflection-free matching

values are understood as being approximate values. For precise

of cables, e.g. in bus systems. With respect to the combination of

Cable type CF9, Nominal cross section *

information on the actually available cables, individual measure-

various cables types and lengths, an adaptation must be provided

Conductor loop consisting of two adjacent cores, aprox.

ments are absolutely required.

via a matching resistor.

Loop resistance in Ω/km approx.

* The following values are approximate values, calculated from measurements of cables with different numbers of cores. The loop resistance can be maximally 5% over the specified value for cables that are very lavishly stranded in bundles (from 12 cores). 0,14

0,25

0,34

276

158

114

78

70

75

85

Loop capacitance up to 7 cores in nF/km approx. * The following values are approximate values, calculated from measurements of cables with different numbers of cores. The loop resistance can be maximally 5% over the specified value for cables that are very lavishly stranded in bundles (from 12 cores). Cable type CF130.UL, Nominal cross section *

16

125

3.8

130 530

2.6

120

130

560

560

600

520

Characteristic wave impedance at 1 kHz in Ω

100

100

90

85

80

75

70

70

70

65

Capacitance: 2 cores versus all others up to 7 cores in nF/km approx.

115

135

135

145

145

170

190

150

185

200

185

255

235

215

225

0,5

0,75

1

1,5

2,5

4

6

10

9.9

6.6

3.8

4

6

10 3.8

276

158

114

78

52

39

26.6

16

9.9

6.6

3.8

120

105

110

125

125

140

140

65

65

90

Loop inductance in µH/km approx.

635

650

640

620

610

610

565

Loop capacitance up to 7 cores in nF/km approx.

Characteristic wave impedance at 1 kHz in Ω

80

Capacitance: 2 cores versus all others up to 12 cores in nF/km approx. Cable type CF10, Nominal cross section *

200 0,14

0,25

0,34

276

158

114

16

Conductor loop consisting of two adjacent cores, aprox. Loop resistance in Ω/km approx.

90

78

52

39

26.6

16

105

110

120

125

150

90

90

80

80

70

65

Loop capacitance from 12 cores in nF/km approx.

80

95

95

105

115

120

130

150

190

190

205

210

230

Loop inductance in µH/km approx.

680

670

620

590

580

575

555

Characteristic wave impedance at 1 kHz in Ω

100

205

0,14

0,25

0,34

0,5

0,75

1

1,5

2,5

4

6

10

276

158

114

78

52

39

26.6

16

9.9

6.6

3.8

125

125

140

140

165

190

75

90

90

650

650

630

630

620

16

Conductor loop consisting of two adjacent cores, aprox.

Loop capacitance from 12 cores in nF/km approx.

6.6 100

590

10

150

9.9 120

105

6

Loop inductance in µH/km approx.

16

100

16

620

4

Loop capacitance up to 7 cores in nF/km approx.

26.6

10

100

2,5

Loop resistance in Ω/km approx.

39 95

6

90

1,5

Cable type CF140.UL, Nominal cross section *

52 85

4

650

1

Capacitance: 2 cores versus all others up to 12 cores in nF/km approx.

2,5

650

0,75

Capacitance: 2 cores versus all others up to 7 cores in nF/km approx.

1,5

80

0,5

Loop capacitance from 12 cores in nF/km approx.

1

670

0,34

Loop capacitance up to 7 cores in nF/km approx.

0,75

Loop inductance in µH/km approx.

0,25

Conductor loop consisting of two adjacent cores, aprox.

0,5

Loop capacitance from 12 cores in nF/km approx.

0,14

Loop resistance in Ω/km approx.

Data and Schedules

Capacitance: 2 cores versus all others up to 7 cores in nF/km approx.

90

85

80

75

75

65

215

245

260

290

290

345

205

225

255

265

275

0,5

0,75

1

1,5

2,5

Capacitance: 2 cores versus all others up to 12 cores in nF/km approx. 180

200

Cable type CF9.UL, Nominal cross section *

0,14

0,25

0,34

276

158

114

78

52

39

26.6

16

9.9

6.6

70

75

85

85

95

100

125

120

100

130 530

16

Conductor loop consisting of two adjacent cores, aprox. Loop resistance in Ω/km approx.

620

Loop capacitance up to 7 cores in nF/km approx.

2.6

Characteristic wave impedance at 1 kHz in Ω

80

80

80

75

70

60

Loop capacitance from 12 cores in nF/km approx.

80

90

100

105

120

130

Capacitance: 2 cores versus all others up to 7 cores in nF/km approx.

310

310

360

370

430

510

Loop inductance in µH/km approx.

670

650

650

620

590

560

560

600

520

Characteristic wave impedance at 1 kHz in Ω

100

100

90

85

80

75

70

70

70

65

Capacitance: 2 cores versus all others up to 7 cores in nF/km approx.

115

135

135

145

145

170

190

150

185

200

185

255

235

215

225

0,5

0,75

1

1,5

2,5

4

6

10

9.9

6.6

3.8

4

6

10

Capacitance: 2 cores versus all others up to 12 cores in nF/km approx. Cable type CF5, Nominal cross section *

0,14

0,25

0,34

0,5

0,75

1

1,5

2,5

4

6

10

16

276

158

114

78

52

39

26.6

16

9.9

6.6

3.8

95

115

135

185

125

Conductor loop consisting of two adjacent cores, aprox.

Conductor loop consisting of two adjacent cores, aprox.

Capacitance: 2 cores versus all others up to 12 cores in nF/km approx.

Loop resistance in Ω/km approx. Loop capacitance up to 7 cores in nF/km approx.

Cable type CF10.UL, Nominal cross section *

Loop capacitance from 12 cores in nF/km approx.

120

90

105

105

135

670

Loop resistance in Ω/km approx.

Loop inductance in µH/km approx.

760

720

670

670

640

150

Loop capacitance up to 7 cores in nF/km approx.

Characteristic wave impedance at 1 kHz in Ω

85

Capacitance: 2 cores versus all others up to 7 cores in nF/km approx. Capacitance: 2 cores versus all others up to 12 cores in nF/km approx.

52

39

26.6

16

110

120

125

150

65

Loop capacitance from 12 cores in nF/km approx.

80

95

95

105

115

120

130

460

Loop inductance in µH/km approx.

680

670

620

590

580

575

555

Characteristic wave impedance at 1 kHz in Ω

100

225

230

330

0,75

1

1,5

2,5

4

6

10

276

158

114

78

52

39

26.6

16

9.9

6.6

3.8

130

125

135

150

165

185

Conductor loop consisting of two adjacent cores, aprox.

110

120

120

135

Loop inductance in µH/km approx.

725

700

690

680

640

640

Characteristic wave impedance at 1 kHz in Ω

80

80

80

75

70

Capacitance: 2 cores versus all others up to 7 cores in nF/km approx.

340

340

16

Conductor loop consisting of two adjacent cores, aprox.

0,14

78 105

80

0,5

Cable type CF2, Nominal cross section *

114

90

210

207

Capacitance: 2 cores versus all others up to 12 cores in nF/km approx.

158

80

325

Loop capacitance from 12 cores in nF/km approx.

276

190

0,34

Loop capacitance up to 7 cores in nF/km approx.

0,34

85

0,25

Loop resistance in Ω/km approx.

0,25

165 0,14

Cable type CF6, Nominal cross section *

200 0,14

Capacitance: 2 cores versus all others up to 7 cores in nF/km approx.

90

85

80

75

75

65

215

245

260

290

290

345

205

225

255

265

275

0,5

0,75

1

1,5

2,5

Capacitance: 2 cores versus all others up to 12 cores in nF/km approx. 180

200

Cable type CF98, Nominal cross section

0,14

0,25

Loop resistance in Ω/km approx.

276

158

Loop capacitance in nF/km approx.

62

75

65

Loop inductance in µH/km approx.

600

565

340

400

420

460

Characteristic wave impedance at 1 kHz in Ω

115

115

275

275

290

330

Capacitance of one core versus all other cores in nF/km approx.

100

120

0,75

1

1,5

2,5

4

6

10

16

9.9

6.6

3.8

0,25

0,34

0,5

114

78

0,34

16

16

16

Conductor loop consisting of two adjacent cores, aprox. Loop resistance in Ω/km approx.

276

158

52

39

26.6

Loop capacitance up to 7 cores in nF/km approx.

110

130

110

110

135

Loop capacitance from 12 cores in nF/km approx.

100

120

130

105

135

Loop inductance in µH/km approx.

690

630

740

730

670

Characteristic wave impedance at 1 kHz in Ω

90

80

85

85

75

Capacitance: 2 cores versus all others up to 7 cores in nF/km approx.

280

305

320

320

370

Capacitance: 2 cores versus all others up to 12 cores in nF/km approx. 230

270

300

260

330

532

More information

www.chainflex.eu

igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

533


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:31 Seite 534

Data and Schedules

Special Cables Information Electrotechnical data

Cable type CF240, Nominal cross section

0,14

0,25

0,34

0,5

0,75

1

1,5

2,5

4

6

Data and Schedules

Special Cables Information Electrotechnical data

10

16

Conductor loop consisting of two adjacent cores, aprox.

Cable type CF21.UL, Energy conductor

0,75

1

1,5

2,5

4

6

10

16

25

35

50

Single impedance in Ω/km approx.

26

19.5

13.3

7.98

4.95

3.3

1.91

1.21

0.78

0.554

0.386

Loop resistance in Ω/km approx.

276

158

114

Operating capacity in nF/km approx.

150

165

190

200

225

245

320

Operating capacity at 1 kHz in nF/km approx.

100

110

120

Operating inductane in µH/km approx.

365

365

350

340

340

340

330

Characteristic wave impedance at 1 kHz in Ω

95

85

80

Characteristic wave impedance at 1 kHz in Ω

95

95

80

80

70

70

60

Capacitance: 2 cores versus all others cores and shield in nF/km approx. 240

300

305

Capacitance of one core versus all other cores in nF/km approx.

130

140

170

170

200

210

270

Cable type CF211, Nominal cross section

0,25

0,34

Cable type CF21.UL, Signal pair

0,34

0,75

1,5

0,14

0,5

0,75

1

1,5

2,5

4

6

10

16

Conductor loop consisting of two adjacent cores, aprox.

Conductor loop consisting of two adjacent cores, aprox.

Loop resistance in Ω/km approx.

158

114

78

Loop resistance in Ω/km approx.

114

52

26.6

Operating capacity at 10 MHz in nF/km approx.

157

145

125

Loop capacitance in nF/km approx.

80

100

130

Characteristic wave impedance at 1 kHz in Ω

75

70

80

Loop inductance in µH/km approx.

580

600

600

Characteristic wave impedance at 10 MHz in  approx.

60

50

60

Characteristic wave impedance at 1 kHz in Ω

90

80

75

0,14

0,25

0,34

0,5

0,75

1

1,5

2,5

4

6

10

Capacitance of one core versus all other cores in nF/km approx.

140

175

240

Cable type CF27.D, Energy conductor 276

158

114

78

52

39

26.6

16

9.9

6.6

3.8

Operating capacity at 10 MHz in nF/km approx.

100

110

115

140

145

150

150

Characteristic wave impedance at 1 kHz in Ω

100

85

85

75

70

65

60

Characteristic wave impedance at 10 MHz in  approx.

70

65

60

50

50

45

0,14

0,25

0,34

0,5

0,75

276

158

114

78

52

Cable type CF11, Nominal cross section

16

Conductor loop consisting of two adjacent cores, aprox. Loop resistance in Ω/km approx.

Cable type CF12, Nominal cross section

0,75

1

1,5

2,5

4

6

10

16

25

35

50

Single impedance in Ω/km approx.

26

19.5

13.3

7.98

4.95

3.3

1.91

1.21

0.78

0.554

0.386

180

Operating capacity in nF/km approx.

170

180

220

220

250

260

285

350

595

60

Operating inductane in µH/km approx.

360

380

355

355

325

310

310

310

310

45

40

Characteristic wave impedance at 1 kHz in Ω

95

90

80

80

70

70

65

65

45

1

1,5

2,5

4

6

10

Capacitance of one core versus all other cores in nF/km approx.

145

150

185

185

205

215

240

295

495

Cable type CF27.D, Signal pair

0,5

0,75

1,5

39

26.6

16

9.9

6.6

3.8

16

Conductor loop consisting of two adjacent cores, aprox. Loop resistance in Ω/km approx.

Conductor loop consisting of two adjacent cores, aprox.

Operating capacity at 10 MHz in nF/km approx.

150

165

200

Loop resistance in Ω/km approx.

78

52

26.6

Characteristic wave impedance at 1 kHz in Ω

70

70

50

Loop capacitance in nF/km approx.

92

100

130

Characteristic wave impedance at 10 MHz in  approx.

45

45

35

Loop inductance in µH/km approx.

650

600

600

Characteristic wave impedance at 1 kHz in Ω

90

80

75

Capacitance of one core versus all other cores in nF/km approx.

170

175

240

Cable type CF113.D, Nominal cross section

0,14

0,25

0,34

0,5

0,75

1

1,5

2,5

4

6

10

16

Conductor loop consisting of two adjacent cores, aprox. Loop resistance in Ω/km approx. Operating capacity at 1 kHz in nF/km approx.

276

158

114

78

55 - 80

65

55

50 - 110

52

39

26.6

16

9.9

6.6

3.8

Characteristic wave impedance at 1 kHz in Ω

110

105

125

75 - 155

Cable type CF111.D, Nominal cross section

0,14

0,25

0,34

0,5

0,75

1

1,5

2,5

4

6

10

78

52

39

26.6

16

9.9

6.6

3.8

16

Conductor loop consisting of two adjacent cores, aprox. Loop resistance in Ω/km approx.

276

Operating capacity at 1 kHz in nF/km approx. (pair shielded)

80

Operating capacity at 1 kHz in nF/km approx. (pair unshielded)

55

Characteristic wave impedance at 1 kHz in Ω (pair shielded)

105

114

65 55

80 130

Characteristic wave impedance at 1 kHz in Ω (pair unshielded)

115

115

90

Cable type CF11.D, Nominal cross section

0,14

0,25

0,34

0,5

0,75

1

1,5

2,5

4

6

10

52

39

26.6

16

9.9

6.6

3.8

16

Conductor loop consisting of two adjacent cores, aprox. Loop resistance in Ω/km approx.

276

158

114

78

Operating capacity at 1 kHz in nF/km approx.

55 - 80

65

55

50 - 110

Characteristic wave impedance at 1 kHz in Ω

110

105

125

75 - 155

534

More information

www.chainflex.eu

igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

535


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:31 Seite 536

Data and Schedules

Special Cables Information Electrotechnical data

Data and Schedules

Special Cables Information Electrotechnical data

Cable type CF30, Nominal cross section

1,5

2,5

4

6

10

16

25

35

50

70

Single impedance in Ω/km approx.

13.3

7.98

4.95

3.3

1.91

1.21

0.78

0.554

0.386

0.272

Cable type CF37.D, Nominal cross section

1,5

2,5

4

6

10

16

25

35

50

70

Single impedance in Ω/km approx.

13.3

7.98

4.95

3.3

1.91

1.21

0.78

0.554

0.386

0.272

Operating capacity in nF/km approx.

145

155

170

170

195

215

220

Operating inductane in µH/km approx.

330

330

320

320

310

300

295

270

Operating capacity in nF/km approx.

120

145

150

200

175

290

Operating inductane in µH/km approx.

340

320

320

310

Characteristic wave impedance at 1 kHz in Ω

95

95

90

90

80

70

310

70

65

Characteristic wave impedance at 1 kHz in Ω

100

95

95

90

Capacitance of one core versus all other cores in nF/km approx.

110

115

130

130

150

160

90

170

200

Capacitance of one core versus all other cores in nF/km approx.

90

110

110

140

130

Cable type CF31, Nominal cross section

1,5

2,5

4

6

10

16

25

35

50

70

Cable type CF38, Nominal cross section

1,5

2,5

4

6

10

16

25

35

50

70

Single impedance in Ω/km approx.

13.3

7.98

4.95

3.3

1.91

1.21

0.78

0.554

0.386

0.272

Single impedance in Ω/km approx.

13.3

7.98

4.95

3.3

1.91

1.21

0.78

0.554

0.386

0.272

Operating capacity in nF/km approx.

190

200

215

235

270

295

300

305

370

500

Operating capacity in nF/km approx.

160

180

190

215

260

Operating inductane in µH/km approx.

330

330

320

320

310

260

260

260

260

260

Operating inductane in µH/km approx.

330

320

320

310

290

Characteristic wave impedance at 1 kHz in Ω

85

80

75

70

70

60

60

60

55

50

Characteristic wave impedance at 1 kHz in Ω

100

85

85

75

70

Capacitance of one core versus all other cores in nF/km approx.

170

180

190

210

240

280

250

285

330

440

Capacitance of one core versus all other cores in nF/km approx.

140

155

170

190

220

Cable type CF300.UL.D, Nominal cross section

1,5

2,5

4

6

Resistance in Ω/km approx.

13.3

7.98

4.95

3.3

Cable type CF34.UL.D, Nominal cross section

1,5

2,5

4

6

10

16

25

35

50

70

Single impedance in Ω/km approx.

13.3

7.98

4.95

3.3

1.91

1.21

0.78

0.554

0.386

0.272

Operating capacity in nF/km approx.

120

145

150

200

175

Cable type CF310.UL, Nominal cross section

1,5

2,5

4

6

Operating inductane in µH/km approx.

340

320

320

310

310

Resistance in Ω/km approx.

13.3

7.98

4.95

3.3

Characteristic wave impedance at 1 kHz in Ω

100

95

95

90

90

Cable type CF330.D, Nominal cross section

1,5

2,5

4

6

Capacitance of one core versus all other cores in nF/km approx.

90

110

110

140

130

Resistance in Ω/km approx.

13.3

7.98

4.95

3.3

Cable type CF35.UL, Nominal cross section

1,5

2,5

4

6

10

16

25

35

50

70

Single impedance in Ω/km approx.

13.3

7.98

4.95

3.3

1.91

1.21

0.78

0.554

0.386

0.272

Operating capacity in nF/km approx.

160

180

190

215

260

Operating inductane in µH/km approx.

330

320

320

310

290

Characteristic wave impedance at 1 kHz in Ω

100

85

85

75

70

Capacitance of one core versus all other cores in nF/km approx.

140

155

170

190

220

536

More information

www.chainflex.eu

Cable type CF340, Nominal cross section

1,5

2,5

4

6

Resistance in Ω/km approx.

13.3

7.98

4.95

3.3

10

16

25

35

50

1.910 1.210 0.780 0.554 0.386 10

16

25

35

50

1.910 1.210 0.780 0.554 0.386 10

16

25

35

50

1.910 1.210 0.780 0.554 0.386 10

16

25

35

50

1.910 1.210 0.780 0.554 0.386

70

95

120

150

185

240

0.272 0.206 0.161 0.129 0.106 0,0801 70

95

120

150

185

240

0.272 0.206 0.161 0.129 0.106 0,0801 70

95

120

150

185

240

0.272 0.206 0.161 0.129 0.106 0,0801 70

95

120

150

185

240

0.272 0.206 0.161 0.129 0.106 0,0801

igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

537


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:31 Seite 538

Data and Schedules

Group

Chemical resistance – Selection Chart

chainflex®cable

Control cable Control cable CF130.UL CF140.UL Control cable Control cable CF5 Control cable CF6 Control cable CF170.D Control cable CF180 Control cable CF77.UL.D Control cable CF78.UL Control cableo CF2 Control cable CF9 Control cable CF10 Control cable CF9.UL Control cable CF10.UL Control cable CF98 Control cable CF99 Data cable Data cable CF240 Data cable CF240 .PUR Data cable CF211 Data cable CF113 Data cable CF11 Data cable CF112 Data cable CF12 Data cable CFKoax Bus cable Bus cable CFBUS.PVC Bus cable CFBUS.PUR Bus cable CFBUS Bus cable CF11.LC Bus cable CF11.LC.D Bus cable CF14 CAT5 Fibre optic cable Fibre optic cable CFLK Fibre optic cable CFLG.2LB Fibre optic cable CFLG.G Measuring system cable Measuring system cable CF211 Measuring system cable CF111.D Measuring system cable CF113.D Measuring system cable CF11.D

Jacket material

PVC PVC PVC PVC PUR PUR PUR PUR PUR TPE TPE TPE TPE TPE TPE

1

2

Chemical resistance

4

1 1 2 2 3 3 3 3 3 4 4 4 4 4 4

PVC PUR PVC PUR TPE PUR TPE TPE

2

PVC PUR TPE TPE TPE TPE

2

Page

58 62 66 70 74 76 78 82 86 90 94 98 102 106 108

4 4

112 114 116 118 120 122 124 126

4 4 4 4

134 136 138 144 146 148

3 2 3 4 3

3

PUR TPE TPE PVC PUR PUR TPE

3

Data and Schedules

3 4 4 2 4 3 4

154 156 158 164 170 174 180

Inorganic chemicals Aqueous solutions, neutral Water Common salt (10%) Glauber's salt (10%) Aqueous solutions, alkaline Soda (10%) Aqueous solutions, acid Sodium bisulfate (10%) Aqueous solutions, oxidizing Hydrogen peroxide (10%) Potassium permanganate (2%) Inorganic acids Hydrochloric acid, concentrated Hydrochloric acid (10%) Sulfuric acid, concentrated Sulfuric acid (10%) Nitric acid, concentrated Nitric acid (10%) Inorganic caustic solutions Soda lye, concentrated Soda lye (10%) Potassium lye, concentrated Potassium lye (10%) Ammonia, concentrated Ammonia (10%) Organic chemicals / organic acids Acetic acid, concentrated (glacial acetic acid) Acetic acid (10% in H20) Tartaric acid (10% in H20) Citric acid (10% in H20) Ketones Acetones Methyl ethyl ketone (MEK) Alcohols Ethyl alcohol (spirit) Isopropyl alcohol Diethylene glycol Aromatic compounds Toluol Xylol Fuels Gasoline Diesel fuel Synthetic oils / lubricating oil ASTM oil #2 Hydraulic oil Mineral oil base Glycol base Synthetic ester base Vegetable oils Rapeseed oil Olive oil Soya bean oil Cold cleaning agent Cold cleaning agent

1

2

3

4

+ + +

+ + +

+ + +

+ + +

O

+

O

+

O

+

O

+

+ +

+ +

+ +

+ +

– O – O – O

– O – O – O

– O – O – –

– + – + – O

– O – O O +

– O – O O +

– O – O O +

O + O + + +

– O O O

– + + +

– O + +

O + + +

– –

– –

– –

O O

– – O

O O O

O O +

+ + +

– –

– –

O O

– –

– –

O O

+ +

+ +

O

+

+

+

– O –

O O O

+ + +

+ + +

O O O

+ + +

+ + +

+ + +

O

+

O

+ no or minimum negative influence O medium reciprocal effect, short-term exposure permissible

All information applies to room temperature

– unstable, material partly destroyed

538

More information

www.chainflex.eu

igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

539


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:31 Seite 540

Data and Schedules

Chemical resistance – Selection Chart

chainflex®cable

Group

Servo cable Servo cable Servo cable Servo cable Servo cable Power cable Power cable Power cable Power cable Power cable Power cable Power cable Power cable Power cable Power cable Power cable Power cable Twistable cable Twistable cable Twistable cable Twistable cable Twistable cable Twistable cable Twistable cable Twistable cable Twistable cable Twistable cable Special cable Data cable Power cable Power cable Bus cable

Jacket material

1

2

CF210.UL CF21.UL CF27.D CF270.UL.D

PVC PVC PUR PUR

2 2

CF30 CF31 CF34.UL.D CF35.UL CF37.D CF38 CF300.UL.D CFPE CF310.UL CF330.D CF340

PVC PVC TPE TPE TPE TPE TPE TPE TPE TPE TPE

2 2

CF ROBOT9 CF77.UL.D CF ROBOT2 CF ROBOT8 CF ROBOT4 CF ROBOT5 CF ROBOT6 CF ROBOT7 CF ROBOT

PUR PUR PUR PUR PUR TPE PUR PUR TPE

CF THERMO CF FLAT CF BRAID CF SP182

PUR TPE TPE PUR

3

Chemical resistance

4

Page

188 190 194 198

3 3

4 4 4 4 4 4 4 4 4 4 3 3 4 3 4 3 3 4 3 4 4 3

Data and Schedules

204 206 208 210 212 214 216 218 220 222 224 236 238 242 244 246 248 250 250 252 256 260 262 264

Inorganic chemicals Aqueous solutions, neutral Water Common salt (10%) Glauber's salt (10%) Aqueous solutions, alkaline Soda (10%) Aqueous solutions, acid Sodium bisulfate (10%) Aqueous solutions, oxidizing Hydrogen peroxide (10%) Potassium permanganate (2%) Inorganic acids Hydrochloric acid, concentrated Hydrochloric acid (10%) Sulfuric acid, concentrated Sulfuric acid (10%) Nitric acid, concentrated Nitric acid (10%) Inorganic caustic solutions Soda lye, concentrated Soda lye (10%) Potassium lye, concentrated Potassium lye (10%) Ammonia, concentrated Ammonia (10%) Organic chemicals / organic acids Acetic acid, concentrated (glacial acetic acid) Acetic acid (10% in H20) Tartaric acid (10% in H20) Citric acid (10% in H20) Ketones Acetones Methyl ethyl ketone (MEK) Alcohols Ethyl alcohol (spirit) Isopropyl alcohol Diethylene glycol Aromatic compounds Toluol Xylol Fuels Gasoline Diesel fuel Synthetic oils / lubricating oil ASTM oil #2 Hydraulic oil Mineral oil base Glycol base Synthetic ester base Vegetable oils Rapeseed oil Olive oil Soya bean oil Cold cleaning agent Cold cleaning agent

1

2

3

4

+ + +

+ + +

+ + +

+ + +

O

+

O

+

O

+

O

+

+ +

+ +

+ +

+ +

– O – O – O

– O – O – O

– O – O – –

– + – + – O

– O – O O +

– O – O O +

– O – O O +

O + O + + +

– O O O

– + + +

– O + +

O + + +

– –

– –

– –

O O

– – O

O O O

O O +

+ + +

– –

– –

O O

– –

– –

O O

+ +

+ +

O

+

+

+

– O –

O O O

+ + +

+ + +

O O O

+ + +

+ + +

+ + +

O

+

O

+ no or minimum negative influence O medium reciprocal effect, short-term exposure permissible

All information applies to room temperature

– unstable, material partly destroyed

540

More information

www.chainflex.eu

igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

541


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:31 Seite 542

Data and Schedules

Information

Information

The General Conditions

Technical notes

The General Conditions of Sale of igus® shall apply. Excessive and short deliveries of ± 10 % for cables conform with contractual agreements. Deliveries can be made in part-lengths. Statutory VAT must be added to the prices. The General Conditions of Sale and Delivery of igus® GmbH, Cologne, can be found online under www.igus.de. The prices quoted in the catalogue or other media are subject to alteration. igus® can modify the prices at any time at their own discretion.

The USB, FireWire and GigE-cables shown on these pages were developed for the ambitious industrial usage in e-chains®. High proofness to oil and lubricants is as secured as protection against electromagnetical interferences. This high mechanical service life was reached with the usage of high quality materials which even care for the electrical safeness.In single cases communication errors can occur, if very different hardware and software is combined. We recommend tests with all components and the cables before starting serial production, to get the proove for a perfect running system. Of course we support you with the details of these electrical tests. Just give us a call!

User information

The specifications in the catalogue referring to temperature range, bending radius and travel must be seen as limiting value specifications. If two limiting value specifications are combined, this can lead to a reduction of the cable's service life. The term "oilresistant" refers to a few selected oil types which have been tested accordingly. This does not mean, however, that the products are automatically resistant to all the oils on the market. Length printing: Respective printing of the metre length is already on many cables. These are not calibrated measurements, they are only intended as an orientation aid. Just give us a call!

Since our products are constantly being developed further in the interest of our customers, we reserve the right to make technical alterations at any time. With the issue of this catalog, all previous publications lose their validity. Subject to printing errors.

Disclaimer

Data and Schedules

The terms "igus", readycable", "readychain", "chainflex", e-chain", "e-chainsystems", "energy chain", "energy chain systems", "e-ketten", "e-kettensysteme", "flizz", "iglidur", "drylin" are legally protected trademarks in the Federal Republic of Germany and in case also in foreign countries.

Outer jacket color according to RAL chainflex® cable jacket colours are given with the similar RAL colour number; for example yellow-green, similar to RAL 6018. Slight differences can occur from the exact RAL colour, depending on the cable jacket material. However, this has no effect on the quality or functionality of the cable. A RAL number is used to describe different shades of colour more consistently. For example, RAL 7040 is light gray and RAL 7016 is a dark gray. The RAL number describes the colour, but cannot guarantee the same shade in different applications. RAL: German Institute for Quality Assurance and Certification EV.

www.RAL.de

KTG If cable drums are to be used, please visit KTG directly online. www.kabeltrommel.de

Product illustrations The products illustrated are photos showing examples for whole series, i.e. the original cable can deviate from the cable shown.

542

More information

www.chainflex.eu

igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

543


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:31 Seite 544

Data and Schedules

Notes

Special Cables Information Approbation and Approvals

igus® chainflex® cables for DESINA DESINA: DEcentral and Standardised INstAllation technique is a recommendation of the Verein Deutscher Werkzeugmaschinenfabriken (VDW = Association of German machine tool industry) for the purpose of standardising components, interfaces and connecting systems. DESINA describes an extensive whole concept for standardisation and decentralisation of the fluid technical and electrical installation of machines and plants. For further information: www.desina.de

Underwriters Laboratories Inc. For further information: www.ul-europe.com

Underwriters Laboratories Inc. For further information: www.ul-europe.com

Canadian Standards Association For further information: www.csa.ca

Commission Électrotechnique Internationale

Communauté Européenne

544

More information

www.chainflex.eu

igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

545


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:31 Seite 546

igus® at www

igus® at www

chainflex® cables Configure and order online

Configure and order cables online igus® provides electronic support Rectangular connectors, Sub D connectors, round connectors – you can now select cables yourself from your workplace or home PC. Experienced users will only need about one and a half minutes to assemble the cable they need via the Internet. The components selected and all available ex-stock can then be placed in a virtual shopping basket and delivered by igus® without delay.

Filter the optimum cable out and order online Using the QuickCable product finder, available online under www.igus.eu/quickcable, users can first search for the optimum technical solution and then make an online inquiry or place an order. Cable selection is via a choice of parameters: electrical, dynamic, mechanical and chemical parameters and environmental questions. Direct cable selection is also possible, of course.

igus & ®

chainflex® cable library for eplan ● The article data of all chainflex® cables are now downloadable in eplan standard! www.igus.eu/eplan-download ● Completely created cable type file, including information on colour codes, cross-sections, shields, etc. ● Cable article file in eplan format for piece lists or order lists ● Fully compatible with eplan 5/eplan 8

i-net customer information system available at www.igus.eu Track your order in real time with igus® i-net. Simply apply for your password, log in and you can then track your job status via webcam. You can also use the igus® i-net carrier tracking system to track your ordered merchandise from the igus® shipping process right up to your front door. ● Webcams ● More precise order data including an overview of target-actual deadlines ● Selection whether you prefer order confirmation or invoice by letter, fax or e-mail

Individual pin assignment Once the cable type has been found, the new QuickPin configurator is the next step. Under www.igus.eu/quickpin, igus® offers all its connector types in a convenient menu, including reason test. The pin or wire contact assignment is flexible, depending on the user's requirements. The contacts can be assigned logically per mouse click, the pole images are then represented by symbols. This means that instead of a list in a table, the pin assignment can be viewed as an image on one page.

Calculate service life online Calculate service life online – depending on the parameters travel, bending radius and speed. The program checks the logical plausibility of the parameters entered. The result is given in the number of double strokes to be expected. If other cable types could achieve better results on the basis of the parameters entered, this will be noted.

546

More information

www.chainflex.eu

igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

547


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:32 Seite 548

More igus® products

More igus® products

igus® at www

igus® at www.igus.eu The entire igus® product range as well as service and latest news can be found on the internet at www.igus.eu Special information of chainflex® can be found on the internet at www.chainflex.eu

Please call your local distributor for more informations about the igus® products.

Catalog

Catalog

energy chain systems®

Polymer Bearings

The complete program of energy chains®

Maintenance free polymer bearings

energy chain systems®

All products can be ordered online by clicking on Catalogs Online

Fast selection of all products and all important information

Free download of 3D product drawings from the Internet More than 20 CAD formats and almost all product drawings available: effective design aid

More than 70.000 products, all features and data Your questions answered by our online energy chain® experts

Polymer Plain Bearings

548

More information

www.chainflex.eu

iglidur® plain bearings. 31 materials, all features and applications

Everything about self-adjusting and maintenance-free igubal® plain bearings

drylin® W, T, N and R. The entire program of linear plain bearings

Polysorb®: Plastic disc springs

Huge product selection with DXF database

More than 20 CAD formats and almos all product drawings available: effective design aid

igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

549


DESINAconforming

UL and/or CSA approval PVC-free/ halogen-free

Cutting and Wel- Timber Processing Low-Temperature ding Systems Machines Applications

Cranes/Harbor Cranes/Materials-Handling Equipment Technology Storage and Systems/Materials- Retrieval Units for HighHandling TechnoBay/ Warehouses/ logy/Outdoor Indoor areas Packaging Handling Automation Machine Tools/ Processing Machines

chainflex速 Quick Selection CF130.UL CF140.UL CF5 CF6 CF170.D CF180 CF77.UL.D CF78.UL CF2 CF9 CF10 CF9.UL CF10.UL CF98 CF99 CF240 CF240.PUR CF211 CF113 CF11

CF112 CF12 CFKoax

CFBUS.PVC CFBUS.PUR CFBUS CF11.LC CF11.LC.D CF14CAT5 CFLK

CFLG.LB CFLG.G CF211 CF111.D CF113.D CF11.D

EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:34 Seite 550

chainflex速 according to Industries

Control Cables

550

Data Cables Bus Cables Fibre optic cables (FOC) Measuring system cables

Page 58 62 66 70 74 76 78 82 86 90 94 98 102 106 108 112 114 116 118 120 122 124 126 134 136 138 144 146 148 154 156 158 164 170 174 180

chainflex速 Quick Selection Page

PVC

551


DESINAconforming

UL and/or CSA approval PVC-free/ halogen-free

Cutting and Wel- Timber Processing Low-Temperature ding Systems Machines Applications

Cranes/Harbor Cranes/Materials-Handling Equipment Technology Storage and Systems/Materials- Retrieval Units for HighHandling TechnoBay/ Warehouses/ logy/Outdoor Indoor areas Packaging Handling Automation Machine Tools/ Processing Machines

chainflex速 Quick Selection CF210.UL CF21.UL CF270.UL.D CF27.D CF30 CF31 CF34.UL.D CF35.UL CF37.D CF38 CF300.UL.D CFPE CF310.UL CF330.D CF340 CFCRANE CFAIR CFClean AIR

CFROBOT9 CF77.UL.D CFROBOT8 CFROBOT4 CFROBOT5 CFROBOT6/7 CFROBOT CFTHERMO CFFLAT CFBRAID

EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:36 Seite 552

chainflex速 according to Industries

Servo Cables

552

Power Cables Hoses Twistable Cables Special Cables

Page 188 190 194 198 204 206 208 210 212 214 216 218 220 222 224 226 228 230 236 238 244 246 248 250 252 256 260 262

chainflex速 Quick Selection Page

PVC

553


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:36 Seite 554

Fax

energy chain systems®

igus® chainflex®

Fax

System Planning

Customer-specific cables for energy chain systems® Fax:

Harnessing

Sender:

Date:

Phone: +49(0)2203/9649-800

Sender:

Recipient:

Fax:

+49(0)2203/9649-222

Recipient:

+49(0)2203/9649-222

igus® GmbH

igus® GmbH

Technical Marketing

Technical Marketing Spicher Str. 1a

Spicher Str. 1a Phone:

51147 Cologne

Phone:

Fax:

Germany

Fax:

51147 Cologne Germany

Planning

Phone: +49(0)2203/9649-800

igus® System

Date:

______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ energy chain® series Bending radius

______________________________ R ______________________________

Velocity

V ______________________________

Acceleration

a ______________________________

Travel distance

S ______________________________

______________________________

Environment Temperature (highest/lowest) Chemical influences (oils, etc.)

______________________________

Outdoor/Indoor use

O■

or

______________________________

______________________________

I■

Shielding Total shield Pair shielding

■ ■

Sheath material PVC PVC oil-resistant PUR TPE Pair shielding Hybrid cable or other

■ ■ ■ ■ ■ ■ ■ ___________________________

Additional options Flame-retardant Halogen-free or other

■ ■ ■ ___________________________

Approbation CE CSA DESINA UL or other

■ ■ ■ ■ ■ ___________________________

Installation space

mm

Overall width:

Fixed point: Travel centre point or

yes

Max. overall width allowed?

mm from centre point

mm Guide exists?

R requested:

Max. overall height HF:

mm

Installation location/floor, wall, console: Velocity:

no

mm

(m/s)

mm

yes. If yes, which guide:

Numeral printing/colour code N ■

mm

Dimensions: HRi

mm

Acceleration:

mm

(m/s2)

Distances/day:

Days/year:

Ø Distance:

Temperature (°C):

Moisture (%):

Dust-dirt-chips:

Special details?: Quantity

Manufacturer/Art. no.

Cross sections

Ø

Weight kg/m

Permissible bending radius

Additional individual components requested: energy chains® / e-tube

energy chains®

chainflex® special cables

e-tube

Guiding troughs

To be opened on both sides

Strain relief

To be opened in outer radius

Harnessing

To be opened in inner radius

Other ___________________________

Dimensions: BRi

Supporting width (standard = 2 m)

Assembly Other items Max. Ø external

(Please check off)

igus® system guarantee requested?

Special requests:

info@igus.de

info@igus.de

■ ■ ■ ■ ■ ■ ■ ■ ___________________________

Travel s:

www.igus.eu

Application case (short description):

or

www.igus.eu

Cable type Data cable Twisted-pair Fibre-optic Bus specification Control cable Power cable Servo cable or other

■ ■ ■ ■ ■ ______________________________

Cores Quantity / Cross section ■ ___________________________

Travel frequency Number of double strokes/ day to be expected ______________________________ Number of manufacturing days to be expected ______________________________

554

Voltage class < 30 V 300/300 V 300/500 V 450/750 V 600/1000 V or operating voltage

Installation type

Environment

51147 Cologne, Germany

igus® GmbH

Mechanical properties of the requested cable

Electrical properties of the requested cable

Dynamics

Technical information

a complete analysis together with a filling proposal and offer. Please call us if you have any questions.

Filling of the energy chains®

Fax +49(0)2203/9649-222

Tel. +49(0)2203/9649-800

Please send us information on your application data to the extent possible. Within 24 hours, you will then receive Special applications in the sector of flexible energy supply systems depend on special cables that function for a long time. As a manufacturer of energy chains® and the corresponding cables, we will plan your specific requirement case on a customized basis – already starting from a cable length of 500 meters. Planning and calculation security will save you time and money. The is why our offers get to the point quickly. Please help us by filling out this questionnaire as completely as possible. With several brief items of information from the selection list, we will be glad to make you an offer. But we will also be pleased to help in person or by telephone with the clarification of technical details.

C■

Estimated requirement/year ___________________________

555


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:36 Seite 556

energy chain systems® Date:

Harnessing Phone: +49(0)2203/9649-800 Fax:

Fax inquiry

chainflex®

Date:

Phone: +49(0)2203/9649-800

+49(0)2203/9649-222

Fax:

Recipient:

Sender:

+49(0)2203/9649-222

Recipient:

igus® GmbH

igus® GmbH

Technical Marketing

Technical Marketing

Spicher Str. 1a

Spicher Str. 1a

Phone:

51147 Cologne

Phone:

51147 Cologne

Fax:

Germany

Fax:

Germany

Planning of ready-made energy chain systems®

for cables conform with contractual agreements. Deliveries can be made in part-lengths. Some chainflex® cables have length information printed on them in metres. igus® expressly points out that these specifications are not calibrated. Statutory VAT must be added to the prices.

Price per unit

Interior separation/separators Sketch of the arrangement of the cables

Connector end 1 Screw connection 1 Excess length 2

Screw connection 2

Connector end 2

Delivery deadline: Signature/stamp

Fax +49(0)2203/9649-222

Quantity

51147 Cologne, Germany

igus® order numbers

info@igus.de

Item number

Tel. +49(0)2203/9649-800

info@igus.de

www.igus.eu

Page_________________of________________pages

We are placing our order based on the general terms and conditions of igus® GmbH. Excessive and short deliveries of ± 10 %

Filling:

Excess length 1

556

Order No.

Length:______________________________

igus® GmbH

Fax +49(0)2203/9649-222 51147 Cologne, Germany

igus® GmbH

Tel. +49(0)2203/9649-800

Chain type:______________________________

www.igus.eu

Harnessing

Sender:

Fax Fax order

Harnessing

Fax

557


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:36 Seite 558

Content

Table of contents according to part number igus® Part No.

Page

Control cable chainflex® CF2 CF2.01.04 CF2.01.08 CF2.01.12 CF2.01.18 CF2.01.24 CF2.01.36 CF2.01.48 CF2.02.04 CF2.02.08 CF2.02.18 CF2.02.24 CF2.02.48 CF2.05.12 CF2.05.18 CF2.07.04 CF2.07.12 CF2.07.24 CF2.10.05 CF2.10.24 CF2.15.03

558

More information

Page

Control cable chainflex® CF6 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86

Control cable chainflex® CF5 CF5.02.36 CF5.03.15 CF5.03.18 CF5.03.25 CF5.05.02 CF5.05.03 CF5.05.05 CF5.05.07 CF5.05.12 CF5.05.18 CF5.05.25 CF5.05.30 CF5.07.03 CF5.07.04 CF5.07.05 CF5.07.07 CF5.07.12 CF5.07.18 CF5.07.25 CF5.07.36 CF5.07.42 CF5.10.03 CF5.10.04 CF5.10.05 CF5.10.07 CF5.10.12 CF5.10.18 CF5.10.25 CF5.15.03 CF5.15.04 CF5.15.05 CF5.15.07 CF5.15.12 CF5.15.18 CF5.15.25 CF5.15.36 CF5.25.04 CF5.25.05 CF5.25.07 CF5.25.12 CF5.25.18 CF5.25.25

igus® Part No.

66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66

CF6.02.04 CF6.02.24 CF6.03.05 CF6.05.02 CF6.05.05 CF6.05.07 CF6.05.09 CF6.05.12 CF6.05.18 CF6.05.24 CF6.07.03 CF6.07.04 CF6.07.05 CF6.07.07 CF6.07.12 CF6.07.18 CF6.07.24 CF6.10.03 CF6.10.04 CF6.10.05 CF6.10.07 CF6.10.12 CF6.10.18 CF6.10.24 CF6.15.03 CF6.15.04 CF6.15.05 CF6.15.07 CF6.15.12 CF6.15.18 CF6.15.25 CF6.15.36 CF6.25.04

70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70

Control cable chainflex® CF9 CF9.01.03 CF9.02.02 CF9.02.03.INI CF9.02.06 CF9.02.07 CF9.02.08 CF9.02.12 CF9.02.20 CF9.03.04.INI CF9.03.05.INI CF9.03.06 CF9.03.08 CF9.03.16.07.03.INI CF9.05.02 CF9.05.03 CF9.05.04 CF9.05.05 CF9.05.07 CF9.05.12 CF9.05.18 CF9.05.25 CF9.05.36 CF9.07.05 CF9.07.07 CF9.07.12 CF9.07.20 CF9.07.25 CF9.10.03 CF9.10.04 CF9.10.05

www.chainflex.eu

90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90

igus® Part No. CF9.10.12 CF9.10.18 CF9.10.25 CF9.15.02 CF9.15.04 CF9.15.05 CF9.15.07 CF9.15.12 CF9.15.18 CF9.15.25 CF9.15.36 CF9.25.04 CF9.25.05 CF9.25.07 CF9.25.12 CF9.25.16 CF9.25.18 CF9.25.25 CF9.40.04 CF9.60.04 CF9.60.05 CF9.100.04 CF9.160.04 CF9.350.04

Page 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90

Control cable chainflex® CF9.UL CF9.UL.02.02 CF9.UL.02.03.INI CF9.UL.02.04 CF9.UL.02.06 CF9.UL.02.07 CF9.UL.02.08 CF9.UL.02.12 CF9.UL.03.04.INI CF9.UL.03.05.INI CF9.UL.03.06 CF9.UL.03.08 CF9.UL.05.02 CF9.UL.05.03 CF9.UL.05.04 CF9.UL.05.05 CF9.UL.05.07 CF9.UL.05.12 CF9.UL.05.18 CF9.UL.05.25 CF9.UL.05.36 CF9.UL.07.05 CF9.UL.07.07 CF9.UL.07.12 CF9.UL.07.20 CF9.UL.07.25 CF9.UL.10.03 CF9.UL.10.04 CF9.UL.10.05 CF9.UL.10.12 CF9.UL.10.18 CF9.UL.10.25 CF9.UL.15.04 CF9.UL.15.05 CF9.UL.15.07 CF9.UL.15.12 CF9.UL.15.18 CF9.UL.15.25 CF9.UL.25.04 CF9.UL.25.05 CF9.UL.25.07 CF9.UL.25.12 CF9.UL.25.16

Content

Table of contents according to part number

98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98

igus® Part No. CF9.UL.25.18 CF9.UL.25.25 CF9.UL.40.04 CF9.UL.60.04

Page 98 98 98 98

Control cable chainflex® CF10 CF10.01.12 CF10.01.18 CF10.02.04 CF10.02.08 CF10.02.12 CF10.02.24 CF10.03.05.INI CF10.05.04 CF10.05.05 CF10.05.07 CF10.05.12 CF10.05.18 CF10.05.25 CF10.07.04 CF10.07.05 CF10.07.07 CF10.07.12 CF10.07.20 CF10.07.24 CF10.10.02 CF10.10.03 CF10.10.04 CF10.10.05 CF10.10.07 CF10.10.12 CF10.10.18 CF10.10.24 CF10.15.04 CF10.15.05 CF10.15.07 CF10.15.12 CF10.15.18 CF10.25.04 CF10.25.07 CF10.25.12 CF10.40.04 CF10.40.05

94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94

Control cable chainflex® CF10.UL CF10.UL.02.04 CF10.UL.02.08 CF10.UL.02.12 CF10.UL.02.24 CF10.UL.05.04 CF10.UL.05.05 CF10.UL.05.12 CF10.UL.05.18 CF10.UL.05.25 CF10.UL.07.03 CF10.UL.07.04 CF10.UL.07.05 CF10.UL.07.07 CF10.UL.07.12 CF10.UL.07.20 CF10.UL.07.24 CF10.UL.10.02 CF10.UL.10.03 CF10.UL.10.04 CF10.UL.10.05 CF10.UL.10.07 CF10.UL.10.12 CF10.UL.10.18

102 102 102 102 102 102 102 102 102 102 102 102 102 102 102 102 102 102 102 102 102 102 102

igus® Part No.

Page

CF10.UL.10.24 CF10.UL.15.04 CF10.UL.15.05 CF10.UL.15.07 CF10.UL.15.12 CF10.UL.15.18 CF10.UL.25.04 CF10.UL.25.07 CF10.UL.25.12 CF10.UL.40.04

102 102 102 102 102 102 102 102 102 102

Data cable chainflex® CF11 CF11.01.04.02 CF11.01.18.02 CF11.02.01.02 CF11.02.02.02 CF11.02.03.02 CF11.02.04.02 CF11.02.05.02 CF11.02.06.02 CF11.02.09.02 CF11.02.10.02 CF11.02.14.02 CF11.03.08.02 CF11.05.04.02 CF11.05.06.02 CF11.05.08.02 CF11.07.03.02 CF11.10.04.02 CF11.15.06.02 CF11.25.03.02

122 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122

Measuring system cable chainflex® CF11.D CF11.001.D CF11.002.D CF11.003.D CF11.004.D CF11.005.D CF11.006.D CF11.007.D CF11.008.D CF11.009.D CF11.010.D CF11.011.D CF11.012.D CF11.013.D CF11.014.D CF11.015.D CF11.016.D CF11.017.D CF11.018.D CF11.019.D CF11.021.D CF11.022.D CF11.025.D CF11.027.D CF11.032.D CF11.033.D CF11.034.D CF11.038.D

180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180

Bus cable chainflex® CF11.LC CF11.02.03.02.IB-S CF11.02.03.02.10.03.IB-S CF11.05.01.02.LC CF11.05.02.02.LC CF11.02.02.02.PBA.LC

144 144 144 144 144

igus® Part No.

Page

Bus cable chainflex® CF11.LC.D CF11.02.01.02.PBA.LC.D CF11.02.02.07.03.PBA.LC.D CF11.02.02.15.04.PBA.LC.D CF11.02.02.02.LC.D CF11.05.01.02.LC.D

146 146 146 146 146

Data cable chainflex® CF12 CF12.02.02.02 CF12.02.03.02 CF12.02.04.02 CF12.02.05.02 CF12.05.03.02 CF12.05.04.02 CF12.05.05.02 CF12.05.06.02 CF12.05.08.02 CF12.05.10.02 CF12.05.14.02 CF12.10.06.02

124 124 124 124 124 124 124 124 124 124 124 124

Bus cable chainflex® CF14 CAT5 CF14.01.04.02.CAT5 CF14.02.02.02.CAT5 CF14.02.04.02.CAT5 CF14.02.05.02.CAT5

148 148 148 148

Servo cable chainflex® CF21.UL CF21.07.05.02.01.UL CF21.15.15.02.01.UL CF21.25.15.02.01.UL CF21.40.15.02.01.UL CF21.60.15.02.01.UL CF21.100.15.02.01.UL CF21.160.15.02.01.UL CF21.250.15.02.01.UL CF21.350.15.02.01.UL CF21.07.03.02.02.UL CF21.10.07.02.02.UL CF21.15.07.02.02.UL CF21.25.15.02.02.UL CF21.40.15.02.02.UL CF21.60.15.02.02.UL CF21.100.15.02.02.UL CF21.160.15.02.02.UL CF21.250.15.02.02.UL CF21.350.15.02.02.UL

190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190

Servo cable chainflex® CF27.D CF27.07.05.02.01.D CF27.15.10.02.01.D CF27.15.15.02.01.D CF27.25.10.02.01.D CF27.25.15.02.01.D CF27.40.15.02.01.D CF27.60.15.02.01.D CF27.100.15.02.01.D CF27.160.15.02.01.D CF27.250.15.02.01.D CF27.350.15.02.01.D CF27.07.03.02.02.D CF27.10.07.02.02.D CF27.15.07.02.02.D CF27.25.15.02.02.D

198 198 198 198 198 198 198 198 198 198 198 198 198 198 198

igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

559


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:36 Seite 560

Content

Table of contents according to part number igus® Part No. CF27.40.15.02.02.D CF27.60.15.02.02.D CF27.100.15.02.02.D CF27.160.15.02.02.D CF27.250.15.02.02.D CF27.350.15.02.02.D CF27.15.05.04.D CF27.25.05.04.D CF27.40.05.04.D CF27.60.05.04.D CF27.07.04.D CF27.10.04.D CF27.15.04.D CF27.25.04.D CF27.500.04.D

Page 198 198 198 198 198 198 198 198 198 198 198 198 198 198 198

Power cable chainflex® CF30 CF30.15.04 CF30.25.04 CF30.25.05 CF30.40.04 CF30.40.05 CF30.60.04 CF30.60.05 CF30.100.04 CF30.100.05 CF30.160.04 CF30.160.05 CF30.250.04 CF30.350.04 CF30.500.04

204 204 204 204 204 204 204 204 204 204 204 204 204 204

Power cable chainflex® CF31 CF31.15.04 CF31.25.04 CF31.25.05 CF31.40.04 CF31.40.05 CF31.60.04 CF31.60.05 CF31.100.04 CF31.100.05 CF31.160.04 CF31.250.04 CF31.350.04 CF31.500.04 CF31.700.04

206 206 206 206 206 206 206 206 206 206 206 206 206 206

Power cable chainflex® CF34.UL.D CF34.UL.15.04.D CF34.UL.25.04.D CF34.UL.40.04.D CF34.UL.60.04.D CF34.UL.60.05.D CF34.UL.100.04.D CF34.UL.100.05.D CF34.UL.160.04.D CF34.UL.160.05.D CF34.UL.250.04.D CF34.UL.60.04.O.PE.D CF34.UL.100.04.O.PE.D CF34.UL.160.04.O.PE.D CF34.UL.500.03.O.PE.D

208 208 208 208 208 208 208 208 208 208 208 208 208 208

Power cable chainflex® CF35.UL CF35.UL.05.04 CF35.UL.07.04

560

More information

210 210

igus® Part No. CF35.UL.15.04 CF35.UL.25.04 CF35.UL.40.04 CF35.UL.60.04 CF35.UL.100.04 CF35.UL.160.04 CF35.UL.250.04 CF35.UL.60.03.O.PE CF35.UL.100.03.O.PE CF35.UL.160.03.O.PE CF35.UL.250.03.O.PE CF35.UL.350.03.O.PE CF35.UL.500.03.O.PE

Page 210 210 210 210 210 210 210 210 210 210 210 210 210

Power cable chainflex® CF37.D CF37.15.04.D CF37.25.04.D CF37.40.04.D CF37.60.04.D CF37.60.05.D CF37.100.04.D CF37.100.05.D CF37.160.04.D CF37.160.05.D CF37.250.04.D CF37.60.04.O.PE.D CF37.100.04.O.PE.D CF37.160.04.O.PE.D CF37.500.03.O.PE.D

212 212 212 212 212 212 212 212 212 212 212 212 212 212

Power cable chainflex® CF38 CF38.05.04 CF38.07.04 CF38.15.04 CF38.25.04 CF38.40.04 CF38.60.04 CF38.100.04 CF38.160.04 CF38.250.04 CF38.60.03.O.PE CF38.100.03.O.PE CF38.160.03.O.PE CF38.250.03.O.PE CF38.350.03.O.PE CF38.500.03.O.PE

214 214 214 214 214 214 214 214 214 214 214 214 214 214 214

Control cable chainflex® CF77.UL.D CF77.UL.02.04.D CF77.UL.03.04.INI CF77.UL.05.04.D CF77.UL.05.05.D CF77.UL.05.07.D CF77.UL.05.12.D CF77.UL.05.18.D CF77.UL.05.25.D CF77.UL.05.30.D CF77.UL.07.03.D CF77.UL.07.04.D CF77.UL.07.05.D CF77.UL.07.07.D CF77.UL.07.12.D CF77.UL.07.18.D CF77.UL.07.20.D CF77.UL.07.36.D CF77.UL.07.42.D CF77.UL.10.02.D CF77.UL.10.03.D

www.chainflex.eu

78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78

igus® Part No. CF77.UL.10.04.D CF77.UL.10.05.D CF77.UL.10.07.D CF77.UL.10.12.D CF77.UL.10.18.D CF77.UL.10.25.D CF77.UL.15.03.D CF77.UL.15.04.D CF77.UL.15.05.D CF77.UL.15.07.D CF77.UL.15.12.D CF77.UL.15.18.D CF77.UL.15.25.D CF77.UL.15.36.D CF77.UL.15.42.D CF77.UL.25.03.D CF77.UL.25.04.D CF77.UL.25.05.D CF77.UL.25.07.D CF77.UL.40.04.D

Page 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78

Page

CF98.03.04.INI CF98.03.07 CF98.03.08 CF98.05.04

106 106 106 106

Control cable chainflex® CF99 CF99.01.02 CF99.01.03 CF99.01.04 CF99.01.07 CF99.01.08 CF99.02.03.INI CF99.02.04 CF99.02.07 CF99.02.08 CF99.03.03 CF99.03.04.INI CF99.03.08

108 108 108 108 108 108 108 108 108 108 108 108

CF111 – Was replaced by CF113 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82

Control cable chainflex® CF98 CF98.01.02 CF98.01.03 CF98.01.04 CF98.01.07 CF98.01.08 CF98.02.03.INI CF98.02.04 CF98.02.07 CF98.02.08 CF98.03.03

igus® Part No.

Data cable chainflex® CF111

Control cable chainflex® CF78.UL CF78.UL.05.04 CF78.UL.05.05 CF78.UL.05.07 CF78.UL.05.09 CF78.UL.05.12 CF78.UL.05.18 CF78.UL.05.25 CF78.UL.07.03 CF78.UL.07.04 CF78.UL.07.05 CF78.UL.07.07 CF78.UL.07.12 CF78.UL.07.18 CF78.UL.07.36 CF78.UL.07.42 CF78.UL.10.03 CF78.UL.10.04 CF78.UL.10.05 CF78.UL.10.07 CF78.UL.10.12 CF78.UL.10.18 CF78.UL.10.25 CF78.UL.15.03 CF78.UL.15.04 CF78.UL.15.05 CF78.UL.15.07 CF78.UL.15.12 CF78.UL.15.18 CF78.UL.15.25 CF78.UL.15.36 CF78.UL.15.42 CF78.UL.25.04 CF78.UL.25.05 CF78.UL.25.07 CF78.UL.40.04

Content

Table of contents according to part number

106 106 106 106 106 106 106 106 106 106

Measuring system cable chainflex® CF111.D CF111.001.D CF111.004.D CF111.006.D CF111.011.D CF111.015.D CF111.020.D CF111.021.D CF111.022.D CF111.027.D CF111.028.D CF111.035.D CF111.038.D

170 170 170 170 170 170 170 170 170 170 170 170

Data cable chainflex® CF112 CF112.02.02.02 CF112.02.03.02 CF112.02.04.02 CF112.02.05.02 CF112.02.06.02 CF112.05.02.02 CF112.05.03.02 CF112.05.04.02 CF112.05.05.02 CF112.05.06.02

122 122 122 122 122 122 122 122 122 122

Data cable chainflex® CF113 CF113.02.02.02 CF113.02.03.02 CF113.02.04.02 CF113.02.05.02 CF113.02.06.02 CF113.02.08.02 CF113.05.02.02 CF113.05.03.02 CF113.05.04.02 CF113.05.05.02 CF113.05.06.02

118 118 118 118 118 118 118 118 118 118 118

Measuring system cable chainflex® CF113.D CF113.001.D CF113.002.D

174 174

igus® Part No. CF113.003.D CF113.004.D CF113.005.D CF113.006.D CF113.007.D CF113.008.D CF113.009.D CF113.010.D CF113.011.D CF113.012.D CF113.013.D CF113.014.D CF113.015.D CF113.016.D CF113.017.D CF113.018.D CF113.019.D CF113.021.D CF113.022.D CF113.025.D CF113.027.D CF113.028.D CF113.032.D CF113.033.D CF113.034.D CF113.036.D CF113.037.D CF113.038.D

Page 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174

Control cable chainflex® CF130.UL CF130.02.03.UL CF130.02.04.UL CF130.02.06.UL CF130.02.07.UL CF130.02.12.UL CF130.02.20.UL CF130.02.25.UL CF130.02.30.UL CF130.03.02.UL CF130.03.05.UL CF130.05.02.UL CF130.05.03.UL CF130.05.04.UL CF130.05.05.UL CF130.05.07.UL CF130.05.12.UL CF130.05.18.UL CF130.05.25.UL CF130.07.02.UL CF130.07.03.UL CF130.07.04.UL CF130.07.05.UL CF130.07.07.UL CF130.07.12.UL CF130.07.18.UL CF130.07.25.UL CF130.07.36.UL CF130.07.42.UL CF130.10.02.UL CF130.10.03.UL CF130.10.04.UL CF130.10.05.UL CF130.10.07.UL CF130.10.12.UL CF130.10.18.UL CF130.10.25.UL CF130.15.02.UL CF130.15.03.UL CF130.15.04.UL CF130.15.05.UL

58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58

igus® Part No. CF130.15.07.UL CF130.15.12.UL CF130.15.18.UL CF130.15.25.UL CF130.15.36.UL CF130.15.42.UL CF130.25.03.UL CF130.25.04.UL CF130.25.07.UL CF130.25.12.UL CF130.40.03.UL CF130.60.04.UL CF130.60.05.UL

Page 58 58 58 58 58 58 58 58 58 58 58 58 58

Control cable chainflex® CF140.UL CF140.02.12.UL CF140.03.05.UL CF140.05.03.UL CF140.05.05.UL CF140.05.18.UL CF140.05.36.UL CF140.07.03.UL CF140.07.04.UL CF140.07.05.UL CF140.07.07.UL CF140.07.12.UL CF140.07.18.UL CF140.07.25.UL CF140.07.36.UL CF140.07.42.UL CF140.10.02.UL CF140.10.03.UL CF140.10.04.UL CF140.10.05.UL CF140.10.07.UL CF140.10.12.UL CF140.10.18.UL CF140.10.25.UL CF140.15.03.UL CF140.15.04.UL CF140.15.05.UL CF140.15.07.UL CF140.15.12.UL CF140.15.18.UL CF140.15.25.UL CF140.15.36.UL CF140.15.42.UL CF140.25.03.UL CF140.25.04.UL

62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62

Control cable chainflex® CF170.D CF170.05.12.D CF170.05.18.D CF170.05.30.D CF170.07.03.D CF170.07.05.D CF170.07.07.D CF170.07.12.D CF170.07.18.D CF170.07.20.D CF170.10.03.D CF170.10.04.D CF170.10.05.D CF170.10.07.D CF170.10.12.D CF170.10.18.D CF170.10.25.D CF170.15.03.D CF170.15.04.D

74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74

igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

561


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:36 Seite 562

Content

Table of contents according to part number igus® Part No.

Page

CF170.15.05.D CF170.15.07.D CF170.15.12.D CF170.15.18.D CF170.15.25.D CF170.25.04.D CF170.25.05.D CF170.25.07.D CF170.40.04.D CF170.60.04.D CF170.100.04.D

74 74 74 74 74 74 74 74 74 74 74

Control cable chainflex® CF180 CF180.05.18 CF180.07.03 CF180.07.05 CF180.07.12 CF180.07.18 CF180.10.05 CF180.10.18 CF180.15.03 CF180.15.04 CF180.15.07 CF180.25.04 CF180.25.05 CF180.25.07

76 76 76 76 76 76 76 76 76 76 76 76 76

Servo cable chainflex® CF210.UL CF210.UL.15.15.02.01 CF210.UL.25.15.02.01 CF210.UL.40.15.02.01 CF210.UL.60.15.02.01 CF210.UL.15.07.02.02 CF210.UL.25.15.02.02 CF210.UL.40.15.02.02 CF210.UL.60.15.02.02

188 188 188 188 188 188 188 188

Data cable chainflex® CF211 CF211.02.01.02 CF211.02.02.02 CF211.02.03.02 CF211.02.04.02 CF211.02.05.02 CF211.02.06.02 CF211.02.08.02 CF211.02.10.02 CF211.02.14.02 CF211.03.03.02 CF211.03.08.02 CF211.03.10.02 CF211.05.01.02 CF211.05.02.02 CF211.05.03.02 CF211.05.04.02 CF211.05.05.02 CF211.05.06.02 CF211.05.08.02 CF211.05.10.02 CF211.05.14.02

116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116

Measuring system cable chainflex® CF211 CF211.001 CF211.002 CF211.006 CF211.009 CF211.010 CF211.011

562

More information

164 164 164 164 164 164

igus® Part No. CF211.014 CF211.016 CF211.017 CF211.018 CF211.019 CF211.020 CF211.022 CF211.027 CF211.028 CF211.038

Page 164 164 164 164 164 164 164 164 164 164

Data cable chainflex® CF240 CF240.01.03 CF240.01.04 CF240.01.05 CF240.01.07 CF240.01.14 CF240.01.18 CF240.01.24 CF240.02.03 CF240.02.04 CF240.02.05 CF240.02.07 CF240.02.08 CF240.02.14 CF240.02.18 CF240.02.24 CF240.03.03 CF240.03.04 CF240.03.05 CF240.03.07 CF240.03.10 CF240.03.14 CF240.03.18 CF240.03.24

112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112

Data cable chainflex® CF240.PUR CF240.PUR.01.03 CF240.PUR.01.04 CF240.PUR.01.05 CF240.PUR.01.07 CF240.PUR.01.14 CF240.PUR.01.18 CF240.PUR.02.03 CF240.PUR.02.04 CF240.PUR.02.05 CF240.PUR.02.07 CF240.PUR.02.08 CF240.PUR.02.14 CF240.PUR.02.18 CF240.PUR.03.03 CF240.PUR.03.04 CF240.PUR.03.05 CF240.PUR.03.07 CF240.PUR.03.14 CF240.PUR.03.18

114 114 114 114 114 114 114 114 114 114 114 114 114 114 114 114 114 114 114

Servo cable chainflex® CF260 CF260 – Was replaced by CF210.UL (PVC) and CF270.UL.D (PUR)

Servo cable chainflex® CF270.UL.D CF270.UL.15.15.02.01.D CF270.UL.25.15.02.01.D CF270.UL.40.15.02.01.D CF270.UL.60.15.02.01.D CF270.UL.100.15.02.01.D

www.chainflex.eu

194 194 194 194 194

igus® Part No. CF270.UL.160.15.02.01.D CF270.UL.07.03.02.02.D CF270.UL.10.07.02.02.D CF270.UL.15.07.02.02.D CF270.UL.25.15.02.02.D CF270.UL.40.15.02.02.D CF270.UL.60.15.02.02.D CF270.UL.100.15.02.02.D CF270.UL.160.15.02.02.D CF270.UL.250.15.02.02.D CF270.UL.350.15.02.02.D CF270.UL.15.10.03.01.D CF270.UL.25.10.03.01.D CF270.UL.60.05.04.D CF270.UL.15.04.D CF270.UL.25.04.D CF270.UL.40.04.D CF270.UL.60.04.D CF270.UL.100.04.D CF270.UL.160.04.D CF270.UL.250.04.D CF270.UL.350.04.D

Page 194 194 194 194 194 194 194 194 194 194 194 194 194 194 194 194 194 194 194 194 194 194

Power cable chainflex® CF300.UL.D CF300.UL.40.01.D CF300.UL.60.01.D CF300.UL.100.01.D CF300.UL.160.01.D CF300.UL.250.01.D CF300.UL.350.01.D CF300.UL.500.01.D CF300.UL.700.01.D CF300.UL.950.01.D CF300.UL.1200.01.D CF300.UL.1500.01.D CF300.UL.1850.01.D

216 216 216 216 216 216 216 216 216 216 216 216

Power cable chainflex® CF310.UL CF310.UL.25.01 CF310.UL.40.01 CF310.UL.60.01 CF310.UL.100.01 CF310.UL.160.01 CF310.UL.250.01 CF310.UL.350.01 CF310.UL.500.01 CF310.UL.700.01 CF310.UL.950.01 CF310.UL.1200.01 CF310.UL.1500.01 CF310.UL.1850.01

220 220 220 220 220 220 220 220 220 220 220 220 220

Power cable chainflex® CF 330.D CF330.60.01.D CF330.100.01.D CF330.160.01.D CF330.250.01.D CF330.350.01.D CF330.500.01.D CF330.700.01.D CF330.950.01.D CF330.1200.01.D CF330.1500.01.D CF330.1850.01.D

222 222 222 222 222 222 222 222 222 222 222

igus® Part No.

Page

CF340.60.01 CF340.100.01 CF340.160.01 CF340.250.01 CF340.350.01 CF340.500.01 CF340.700.01 CF340.950.01 CF340.1200.01 CF340.1500.01 CF340.1850.01

224 224 224 224 224 224 224 224 224 224 224

Special cable chainflex® CF BRAID CFBRAID.25.08 CFBRAID.25.08.C

262 262

Bus cable chainflex® CF BUS CFBUS.001 CFBUS.002 CFBUS.003 CFBUS.010 CFBUS.011 CFBUS.020 CFBUS.021 CFBUS.022 CFBUS.030 CFBUS.031 CFBUS.035 CFBUS.040 CFBUS.041 CFBUS.042 CFBUS.044 CFBUS.045 CFBUS.050 CFBUS.055 CFBUS.060 CFBUS.065 CFBUS.066 CFBUS.070

138 138 138 138 138 138 138 138 138 138 138 138 138 138 138 138 138 138 138 138 138 138

Bus cable chainflex® CF BUS.PUR CFBUS.PUR.001 CFBUS.PUR.021 CFBUS.PUR.022 CFBUS.PUR.045 CFBUS.PUR.060

134 134 134 134 134

Bus cable chainflex® CF BUS.PVC CFBUS.PVC.001 CFBUS.PVC.021 CFBUS.PVC.022 CFBUS.PVC.045 CFBUS.PVC.060

136 136 136 136 136

Power cable chainflex® CF CRANE CFCRANE.1x25/16-6/10kV CFCRANE.1x35/16-6/10kV CFCRANE.1x50/16-6/10kV CFCRANE.1x70/16-6/10kV CFCRANE.1x95/16-6/10kV CFCRANE.1x120/16-6/10kV

226 226 226 226 226 226

Special cable chainflex® CF FLAT

Power cable chainflex® CF 340 CF340.40.01

Content

Table of contents according to part number

224

CFFLAT.25.01 CFFLAT.40.01

260 260

igus® Part No.

Page

Coax cable chainflex® CF Koax 1 CFKoax1.01 CFKoax1.05 CFKoax2.01

126 126 126

252 252 252 252 252

242 242 242 242

Twistable cable chainflex® CFROBOT4 CFROBOT4.001 CFROBOT4.002 CFROBOT4.009 CFROBOT4.015 CFROBOT4.028

246 246 246 246 246

Twistable cable chainflex® CFROBOT5 CFRobot5.500 CFRobot5.501

248 248

Twistable cable chainflex® CFROBOT6 CFROBOT6.100.03 CFROBOT6.160.03 CFROBOT6.250.03 CFROBOT6.350.03

250 250 250 250

250 250 250 250 250 250 250 250

256 256 256 256

Fibre optic cable (FOC) chainflex® CFLG.2H Was replaced by CFLG.LB

Fibre optic cable (FOC) chainflex® CFLG.LB 156 156

Fibre optic cable (FOC) chainflex® CFLG. G CFLG.6G.62,5/125.TC CFLG.12G.62,5/125.TC CFLG.6G.50/125.TC CFLG.12G.50/125.TC

158 158 158 158

Fibre optic cable (FOC) chainflex® CFLK CFLK.L1.01

154

Power cable chainflex® CFPE CFPE.15.01 CFPE.25.01 CFPE.40.01 CFPE.60.01 CFPE.100.01 CFPE.160.01 CFPE.250.01 CFPE.350.01

218 218 218 218 218 218 218 218

Special cable chainflex® CFSPECIAL.182 CFSPECIAL.182.001 CFSPECIAL.182.045

Twistable cable chainflex® CFROBOT7 CFROBOT7.15.03.C CFROBOT7.25.03.C CFROBOT7.15.04.C CFROBOT7.25.04.C CFROBOT7.60.04.C CFROBOT7.15.15.02.02.C CFROBOT7.25.15.02.02.C CFROBOT7.40.02.02.04.C

CFTHERMO.J.001 CFTHERMO.K.001 CFTHERMO.K.002 CFTHERMO.T.002

CFLG.2LB.62,5/125 CFLG.2LB.50/125

Twistable cable chainflex® CFROBOT2 CFROBOT2.07.04.C CFROBOT2.07.05.C CFROBOT2.07.12.C CFROBOT2.07.18.C

Page

Special cable chainflex® CF THERMO

Twistable cable chainflex® CFROBOT CFROBOT.035 CFROBOT.036 CFROBOT.037 CFROBOT.038 CFROBOT.039

igus® Part No.

264 264

Special cable chainflex® CFSPECIAL.414 CFSPECIAL.414.02.04 CFSPECIAL.414.02.06 CFSPECIAL.414.02.08 CFSPECIAL.414.03.04 CFSPECIAL.414.03.06 CFSPECIAL.414.03.08

265 265 265 265 265 265

Twistable cable chainflex® CFROBOT8 CFROBOT8.001 CFROBOT8.022 CFROBOT8.045 CFROBOT8.060

244 244 244 244

Twistable cable chainflex® CFROBOT9 CFROBOT9.001 CFROBOT9.002 CFROBOT9.003 CFROBOT9.004 CFROBOT9.005 CFROBOT9.006 CFROBOT9.007

236 236 236 236 236 236 236

igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

563


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:38 Seite 564

564

565


EU-CF-UM 2012-06 A5_EU-CF-UM 2012-06 A5 07.05.12 16:29 Seite 2

chainflex® cable's classification according to the criteria requirements, oil-resistance and travel distance.

Give us your opinion!

Definition of the icons used in the catalogue

Yes, we can! Catalogue improvement. The chainflex® class is composed of 3 parts: Requirements 1 to 7

Travel distance 1 to 4

Requirements

Resistance to oil 1 to 4

Travel distance

To make the choice easier for you, we have classified all chainflex® cables according to the criteria "requirements, oil-resistance and travel distance". The higher the number the better the cable.

Dear costumers,

Example: You are looking for a cable which is suitable for the highest mechanical load. In addition, it should be oil-resistant following DIN EN 50363-10-2. The travel distance should be up to 100 m for freely suspended and gliding applications.

with every new chainflex® catalogue we agonize about how we can do the catalogue easier and better. And we know our catalogue so well that many details are totally clear for us. Then a costumer asks a detailed question and we notice, that it is not said that clear in the catalogue.

You choose from the classification overview (see left page): 1: Flexible cables

1: freely suspended

2: Highly flexible cables

2: freely suspended and gliding up to 50 m

3: Chain-suitable cables without special structure (e.g. stranding in layers) for the use in e-chains®.

3: freely suspended and gliding up to 100 m

4: Cables with special structure for permanent movement in e-chains® for medium requirements and radii from 7.5 x d, speed up to 3 m/s 5: Cables for permanent movement in e-chains® for high-load requirements and radii from 6.8 x d, speed up to 10 m/s 6: Cables for permanent movement in e-chains® for highest load requirements and radii from 5 x d, speed up to 10 m/s 7: Cables for permanent movement in e-chains® for highest load requirements and smallest radii, indoor and outdoor, radii from 4 x d, speed up to 10 m/s and more

4: freely suspended and gliding up to 400 m and more

Resistance to oil

Requirements: Travel distance: Resistance to oil:

6 3 3

This results in the cable's class – here "Class 6.3.3" that you can take out of each product's page.

Rainer Rössel Head of Business Unit chainflex® cables igus® GmbH, Germany

That's why we ask you for your oppinion. What do you like in the catalogue? And more important: What do you like not?

Send us an e-mail to chainflex-katalog@igus.de

Temperature range moved

Temperature range fixed

v max. unsupported/gliding

Torsion

a max.

Travel distance

UV-resistant

Nominal voltage

Testing voltage

Oil

Offshore

Flame-retardant

Silicon-free

Halogen-free

Lead free

Outer jacket

Outer jacket

CFRIP

Inner jacket

Intermediate jacket

Core stranding

Core identification

Conductor

Fibre Cables

Core insulation

Overall shield

Center element

Filling

Element shield

Element jacket

Material

Dimensions

Operating pressure

Vacuum

UL

UL/CSA

CSA

CEI

CE

DESINA

Clean room

NFPA

Toxicity

Gas density

Every comment is welcome - whether it's concerning usability, design, delivery tables, the tests or technical data. Thanks in advance for your cooperation.

1: No resistance to oil 2: Oil-resistant (following DIN EN 50363-4-1) 3: Oil-resistant (following DIN EN 50363-10-2) 4: Oil-resistant (following DIN EN 60811-2-1), bio-oilresistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA)

Best Regards Rainer Rössel Head of Business Unit chainflex® cables igus® GmbH, Germany

In theory the following classes would be possible: lowest "Class 1.1.1", highest "Class 7.4.4"


Chain – cable – guarantee! Ask for fully harnessed and preassembled readychains® – increase your cash-flow and profit immediately. The igus® system guarantee also covers components delivered loose. www.readychain.eu

.eu/... ®

igus® GmbH Spicher Str. 1a D-51147 Cologne Tel. +49-(0)2203/9649-800 Fax +49-(0)2203/9649-222 info@igus.de www.igus.eu © 2012 igus® GmbH

®

®

Subject to technical alterations! MAT 0070582.20 Stand 6.2012

The goods leave igus® within 24 hrs. On request we can deliver via express or special delivery. Please inform us about your wishes.

No minimum order

igus® has no minimum order. Just order the amount you need.

From 1 m

Because chainflex® cables are of special high quality only the necessary length should be ordered. We appreciate each order from 1 m. Above orders of 1 m you may plan in 0.5 m steps.

With guarantee

Beyond the legal guarantee we also vouch for wear and tear. Together with you, we define your application‘s parameters. With a guarantee certificate!

Ordering times

From Monday to Friday 7.00 am - 8.00 pm Saturday 8.00 am - 12.00 pm

Hotline

Phone +49-22 03-96 49-800 Fax +49-22 03-96 49-222

Online shop

See www.igus.eu. There you can find our whole product range. Order around the clock.

You have questions?

For questions and more information call us or use our online product finders on www.chainflex.eu

www.chainflex.eu

.eu

/readychain

24 hrs delivery time

®

Certified according to DIN ISO 9001:2008

cables

/9001.2008

.eu...chainflex.cables...6.2012...plastics.for.longer.life...

Online shopping – 24h! www.igus.eu/24

chainflex

.eu/24 ®

®

Ordering and deliveries weekdays from 7.00 am - 8.00 pm, Saturday from 8.00 am - 12.00 pm. No minimum order quantities, no surcharges. 80,000 e-chain® products available ex stock. Prompt delivery. "Service around-the-clock". www.igus.eu Phone: +49-2203-9649-0 Fax: -222

chainflex.cables...6.2012...

www.chainflex.eu

.eu/... ®

plastics...

EU-CF-UM 2012-06 A5_EU-CF-UM 2012-06 A5 07.05.12 16:28 Seite 1


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.