1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519 Architecture | Graphic Design | Interiors | Landscape Architecture | Planning
Project Name
Date
Document Title
Community College of Baltimore County Interior Signage Program - Design Intent Documentation
07.08.2013
Design Intent Documentation ISSUE FOR BID
Project No. 21134.00
Copyright © 2012 AYERS | SAINT | GROSS
No. Date
0.0
DRAWING INDEX
SECTION 1
SIGN TYPE OVERVIEW
1.1 1.2
Sign Type Overview Sign Type Overview
SECTION 2
GRAPHIC STANDARDS
2.1 2.2 2.3
Type Specifications Symbol Specifications Graphic Icon Specifications
SECTION 3
SIGN TYPE ELEVATIONS, DETAILS, AND GRAPHIC LAYOUTS
--
Notes These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products. The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer. All materials used are to be as specified and/or meet or exceed all required local and national codes.
3.1 Sign Types A1 and A2 (Sign Panel Component) Elevation Views 3.2 Sign Type A2 Elevation Views 3.3 Sign Types A3 and A4 (Sign Panel Component) Elevation Views 3.4 Sign Types A3 and A4 (Sign Panel Component) Elevation Views 3.5 Sign Type A4 Elevation Views 3.6 Name Panel (Sign Types A2 and A4) Elevation Views 3.6_alt Name Panel (Sign Types A2 and A4) Elevation Views - Alternate Fabrication 3.7 Name Panel (Sign Types A2 and A4) Graphic Layouts 3.8 Sign Type A5 Elevation Views 3.9 Sign Type A5B Elevation Views 3.10 3.11
Sign Types Sign Types
B1, B2, B3, B4, B5, B6, B7, B8, and B10 Elevation Views B1, B2, B4, B5, B6, B7, B8, and B10 Graphic Layouts
3.12 Sign Type D1 Elevation Views and Details 3.13 Sign Type D1 Elevation Views and Details 3.14 Sign Type D1 Insert Graphic Layout 3.15 3.16
Sign Types Sign Types
D2A, D2B, and D2C D2A, D2B, and D2C
All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages. • Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment. Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications. Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519
Elevation Views Graphic Layout and Side View
3.17 Sign Type D3A Elevation Views 3.18 Sign Type D3B Elevation Views 3.19 Sign Type D4 Elevation Views and Graphic Layouts 3.20 Sign Type D5 Elevation Views SECTION 4
MOUNTING ELEVATIONS
4.1 4.2 4.3 4.4 4.5
Sign Types Sign Types Sign Types Sign Types Sign Types
4.6 4.7
Revision
A1, A2, A3, A4, A5, and A5B Mounting Elevations B1, B2, B3, B4, B5, B6, B7, B8, and B10 Mounting Elevation D1, D2A, D2B, and D2C Mounting Elevations D3A and D3B Mounting Elevations D4 and D5 Mounting Elevations Existing Signage Removal / Restoration Elevations Existing Signage Removal / Restoration Elevations
Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program
Sheet Title
Drawing Index
Date
07.08.2013
Sheet No.
0.0 Copyright © 2012 AYERS | SAINT | GROSS
Section
SIGN TYPE OVERVIEW
1
Copyright © 2012 AYERS | SAINT | GROSS
Sign Type: A1 Room Identification Sign
SUITE 200
Sign Type: A2 Room Identification Sign w/ Magnetic Name Plate
224
Sign Type: A3 Department Identification Sign
220B
Alejandra Splatafora, Ed.D
Center for Academic Career & Life Planning
Sign Type: A4 Department Identification Sign w/ Magnetic Name Plate
220B Center for Academic Career & Life Planning
No. Date
Revision
--
Notes These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products. The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer. All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner.
Alejandra Splatafora, Ed.D
Sign Type: A5 Utility Room Sign Sign types A2 and A4 include modular components (Sign Panel and removable Name Panel) as shown below
Sign Panel
Sign Type: A5B Utility Room Sign (wider message condition)
220
220
ELECTRICAL CLOSET
ELECTRICAL MECHANICAL OPERATIONS
Sign Type: B1-B10 Typical Core and Restroom Signs
Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages. • Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment. Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications. Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519
RESTROOM
Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
removable Name Panel Project Name
Sign Panel for sign type A1 shall be of identical construction to Sign Panel for sign type A2 to allow for future addition of Name Panels by Owner Sign Panel for sign type A3 shall be of identical construction to Sign Panel for sign type A4 to allow for future addition of Name Panels by Owner Name Panels shall be interchangeable between sign types A1, A2, A3, and A4
Community College of Baltimore County Interior Signage Program
Sheet Title
Sign Type Overview
Date
Sheet No.
07.08.2013
1.1 Copyright © 2012 AYERS | SAINT | GROSS
Sign Type: D1 Building / Floor Directory
Sign Type: D2A Wall Mounted Directional - Small
2
LEVEL 1 Career Center International Student Services Academic Advisement Center Disability Support Services Testing Center LEVEL 2 Student Success Center Reading & World Language
Sign Type: D2C Wall Mounted Directional - Large
No. Date
201-222 Records & Registration Student Services
Classroom & Academic Support Center LOWER LEVEL Office of Judicial Affairs Office of Public Safety Enrollment Services Admissions Office Bursar’s Office Financial Aid Registrar’s Office
Sign Type: D2B Wall Mounted Directional - Medium
201-222 Records & Registration Student Services
201-222 Records & Registration Student Services
223-255 Counseling Center
223-255 Counseling Center
Financial Aid Center and Additional Text
Financial Aid Center and Additional Text
--
Notes These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products. The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer.
001 Suite 003 011 Suite 012 Suite 013 Suite 014 Suite 015
All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages.
Suite 103 Suite 105 120-156 131
Suite 203 208
Revision
Sign Type: D3B Ceiling Mounted Key Destination Identification Sign
Enrollment Office
Sign Type: D3A Oversized Key Destination Sign (special exceptionwhere site conditions permit only)
Sign Type: D4 Flag Mounted Key Destination Sign
Office of Public Safety Sign Type: D5 Flag Mounted Symbol Sign
• Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment. Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications. Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519 Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program
Disability Support Services Testing Center International Student Services
Sheet Title
Sign Type Overview
Date
Sheet No.
07.08.2013
1.2 Copyright © 2012 AYERS | SAINT | GROSS
Section
GRAPHIC STANDARDS
2
Copyright © 2012 AYERS | SAINT | GROSS
Frutiger LT Std 65 Bold
ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz 0123456789
No. Date
Revision
--
Notes These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products. The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer. All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages.
Frutiger LT Std 55 Roman
ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz 0123456789 Frutiger LT Std 45 Light
ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz 0123456789
• Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment. Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications. Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519 Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program
Sheet Title
Type Specifications
Date
07.08.2013
Sheet No.
2.1 Copyright © 2012 AYERS | SAINT | GROSS
Symbols
No. Date
Revision
--
Notes These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products.
S4
Vector Artwork “S4.eps” Women
S7
S6
S5
Vector Artwork “S5.eps” Men
Vector Artwork “S6.eps” Accessible
Vector Artwork “S7.eps” Accessible Restroom (Unisex)
S8
Vector Artwork “S8.eps” Accessible Restroom (Men)
S9
Vector Artwork “S9.eps” Accessible Restroom (Women)
The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer. All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages.
S10
Vector Artwork “S10.eps” Child Restroom
S11
Vector Artwork “S11.eps” Elevator
S12
Vector Artwork “S12.eps” Stairs
S13
S14
Vector Artwork “S13.eps” Accessible Child Restroom
Vector Artwork “S14.eps” Unisex Restoroom
S11
Vector Artwork “S15.eps” Accessible Lift
• Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment. Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications. Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519
S3L
Vector Artwork “S3L.eps” Left Arrow (Circle Denotes Arrow Size)
S3Z
Vector Artwork “S3Z.eps” Left Diagonal Arrow (Circle Denotes Arrow Size)
S3U
Vector Artwork “S3U.eps” Up Arrow (Circle Denotes Arrow Size)
S3X
Vector Artwork “S3X.eps” Right Diagonal Arrow (Circle Denotes Arrow Size)
S3R
Vector Artwork “S3R.eps” Right Arrow (Circle Denotes Arrow Size)
S3D
Vector Artwork “S3D.eps” Down Arrow (Circle Denotes Arrow Size)
Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program
Sheet Title
Symbol Specifications S3LD
Vector Artwork “S3LD.eps” Up, Left Arrow (Circle Denotes Arrow Size)
S3LD2
Vector Artwork “S3LD2.eps” Up, Left Diagonal Arrow (Circle Denotes Arrow Size)
S3UR
Vector Artwork “S3UR.eps” Left Diagonal, Up Arrow (Circle Denotes Arrow Size)
S3UL
Vector Artwork “S3UL.eps” Right Diagonal, Up Arrow (Circle Denotes Arrow Size)
S3RD2
Vector Artwork “S3RD2.eps” Up, Right Diagonal Arrow (Circle Denotes Arrow Size)
S3RD
Vector Artwork “S3RD.eps” Up, Right Arrow (Circle Denotes Arrow Size)
Date
07.08.2013
Sheet No.
2.2 Copyright © 2012 AYERS | SAINT | GROSS
Graphic Icons
No. Date
Revision
--
Notes These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products. The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer.
“L4.eps” Vector Artwork Sign Type D1
All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages. • Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment.
“L5.eps” Vector Artwork Sign Types D2A, D2B, D2C
Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications. Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
“L6.eps” Vector Artwork Sign Types A1, A2, A3, A4, A5
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519
“L7.eps” Vector Artwork Sign Type A5B Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program
“L8.eps” Vector Artwork Sign Types D3A, D3B
“L9.eps” Vector Artwork Sign Types D4, D5
Sheet Title
Graphic Icon Specifications
Date
07.08.2013
Sheet No.
2.3 Copyright © 2012 AYERS | SAINT | GROSS
Section
SIGN TYPE ELEVATIONS, DETAILS, AND GRAPHIC LAYOUTS
3
Copyright © 2012 AYERS | SAINT | GROSS
7" 3/4” OC
1/2”
1/8” 5 3/8”
1/4”
5/8”
224
3/8” OC
3 1/4”
1 3/8”
align
No. Date
--
Sign Panel 1/16” thk pre-finished aluminum laminated to 3/16” thk acrylic Finish: #220 Inline Edges and Corners: Eased Aluminum Edges: Brushed Acrylic Edges: Surface painted PMS 293C Mounting: Laminated to Mounting Spacers
Mounting Spacers (2)
The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer.
Tactile Copy / Braille Romark ADA Alternative Applique 1/32” thk with adhesive back Material: Single-ply modified acrylic Finish: Matte non-glare Color: 3X1-307 Charcoal Gray Type: Frutiger LT Std 55 Roman Copy Height: 5/8” Tall Braille Process: Clear redundant raster bead braille
Front Elevation - A1 and A2 (Sign Panel Component) Scale: 1” = 1”
Notes These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products.
Wall Surface
All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages.
VHB Tape
Graphic Accent Etched and filled PMS 293C File Name: “L6.eps”
A
Revision
B
Section View Scale: 1” = 1”
• Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment. Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications.
1/8”
Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
VHB Tape 1/32” thk Adhears sign to Wall Surface Wall Surface: Varies
3 1/8”
3 1/4”
Mounting Spacers (2) 1/8” thk clear routed acrylic, Edges: Flame polished Mounting: Laminated to back of Sign Panel and VHB Tape to Wall Surface Wall Surface: Varies
High Strength Magnet 1/16” thk, laminated to back of Sign Panel
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519 Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program
Sheet Title
Sign Panel (back view)
C
Rear Elevation - A1 and A2 (Sign Panel Component) Scale: 1” = 1”
Sign Types A1 and A2 (Sign Panel Component) Elevation Views Date
07.08.2013
Sheet No.
3.1 Copyright © 2012 AYERS | SAINT | GROSS
High Strength Magnet Wall Surface
C
1/32” thk VHB Tape
No. Date
Mounting Spacers (2)
--
Plan View Scale: 1” = 1”
Revision
Notes These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products. The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer.
1/8” Reference Sheet No. 3.1 for Sign Panel Specifications
1/4”
All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages.
224
Mounting Spacers (2)
• Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment. Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications. Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
1/32” thk VHB Tape
Sign Panel and Name Panel must align to form a consistent edge profile
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519
Wall Surface
Firstname Lastname, Ed.D
Felt Spacers (2)
Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program Mounting Sleeve
Sheet Title
A
Front Elevation - A2 Scale: 1” = 1”
Reference Sheet No. 3.6 and 3.7 for Name Panel Specifications
B
Section View Scale: 1” = 1”
Sign Type A2 Elevation Views
Date
07.08.2013
Sheet No.
3.2 Copyright © 2012 AYERS | SAINT | GROSS
7" 3/4” OC
1/2”
1/8” 5 3/8”
1/4” No. Date
Revision
1 3/8”
align
--
These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products. The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer.
Tactile Copy / Braille Romark ADA Alternative Applique 1/32” thk with adhesive back Material: Single-ply modified acrylic Finish: Matte non-glare Color: 3X1-307 Charcoal Gray Type: Frutiger LT Std 55 Roman Copy Height: 5/8” Tall Braille Process: Clear redundant raster bead braille
3/8” OC
5/8”
224
Notes
All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages.
1 1/2”
Graphic Accent Etched and filled PMS 293C File Name: “L6.eps”
7/8”
7 3/4”
Center for Academic Career & Life Planning 5 1/4” max. message length
Mounting Spacers (2)
• Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment.
Identification Copy Surface screened MP 10269 Type: Frutiger LT Std 55 Roman Copy Height: 5/8” Tall
Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications.
Wall Surface
Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
1/32” thk VHB Tape
Sign Panel 1/16” thk pre-finished aluminum laminated to 3/16” thk acrylic Finish: #220 Inline Edges and Corners: Eased Aluminum Edges: Brushed Acrylic Edges: Surface painted PMS 293C Mounting: Laminated to Mounting Spacers
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519 Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program
Sheet Title
A
Front Elevation - A3 and A4 (Sign Panel Component) Scale: 1” = 1”
B
Section View Scale: 1” = 1”
Sign Types A3 and A4 (Sign Panel Component) Elevation Views Date
07.08.2013
Sheet No.
3.3 Copyright © 2012 AYERS | SAINT | GROSS
1/8”
No. Date
Mounting Spacers (2) 1/8” thk clear routed acrylic, Edges: Flame polished Mounting: Laminated to back of Sign Panel and VHB Tape to Wall Surface Wall Surface: Varies
Revision
--
Notes These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products. The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer. All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages.
7 3/4”
VHB Tape 1/32” thk Adhears sign to Wall Surface Wall Surface: Varies
• Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment. Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications. Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
3 1/8”
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519
High Strength Magnet 1/16” thk, laminated to back of Sign Panel Include on both A1 and A2 signs for future additions of Name Panels
Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program
Sign Panel (back view) Sheet Title
A
Rear Elevation - A3 and A4 (Sign Panel Component) Scale: 1” = 1”
Sign Types A3 and A4 (Sign Panel Component) Elevation Views Date
07.08.2013
Sheet No.
3.4 Copyright © 2012 AYERS | SAINT | GROSS
1/32” thk VHB Tape
Wall Surface
Mounting Spacers (2)
C
High Strength Magnet
Plan View Scale: 3/4” = 1” 7"
3/4” OC
No. Date
Reference Sheet No. 3.3 and 3.4 for Sign Panel Specifications
1/2”
Revision
--
1/8” 5 3/8”
1/4” Notes
1 3/8”
align
These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products. The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer.
3/8” OC 5/8”
220B
All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages.
Center for Academic Career & Life Planning
3/4”
7 3/4”
1 3/8”
Mounting Spacers (2)
13/16”
1/8”
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
Wall Surface
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519
1/32” thk VHB Tape
Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program
Firstname Lastname, Ed.D
5/8”
2”
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications.
Sign Panel and Name Panel must align to form a consistent edge profile
Front Elevation - A4 Scale: 3/4” = 1”
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment.
5 1/4” max. message length
A
• Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
Mounting Sleeve Felt Spacers (2)
Reference Sheet No. 3.6 and 3.7 for Name Panel Specifications
Sheet Title
Sign Type A4 Elevation Views
Date
B
Side View Scale: 3/4” = 1”
07.08.2013
Sheet No.
3.5 Copyright © 2012 AYERS | SAINT | GROSS
7" 1 1/4”
4 1/2”
1 1/4” No. Date
Wall Surface
Revision
--
C
Notes
Plan View Scale: 1” = 1”
These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products. The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer.
1/16”
7" 1 1/4”
4 1/2”
All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner.
1 1/4”
Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages.
Mounting Sleeve 1/8” thk clear routed acrylic, Edges: Flame polished Mounting: Slides behind Sign Panel (Ref. Sheet 3.3)
• Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment.
3”
Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications. Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
1/32” thk metal sheeting laminated to face of Mounting Sleeve
1/16”
1/16”
5”
3/16”
2”
Firstname Lastname, Ed.D Front Elevation - Name Panel Scale: 1” = 1”
Name Panel 1/16” thk clear matte acrylic laminated to 3/16” thk acrylic Background Process: Second surface painted MP 10269 (between layers) Edges: Flame polished Mounting: Laminated to Mounting Sleeve
Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program
Felt Spacers (2) 1/32” thk, match thickness of VHB Tape or Rigid Mounting Plate
Name Copy 3M Controltac Plus Graphic Films Color: 150C-10 Matte White Type: Frutiger LT Std 45 Light Copy Height: Varies, Reference Sheet No. 3.7
Sheet Title
Mounting Sleeve
1/8”
A
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519
Wall Surface
B
Section View Scale: 1” = 1”
Name Panel (Sign Types A2 and A4) Elevation Views Date
07.08.2013
Sheet No.
3.6 Copyright © 2012 AYERS | SAINT | GROSS
7" 1 1/4”
4 1/2”
1 1/4” No. Date
Wall Surface
Revision
--
C
Notes
Plan View Scale: 1” = 1”
These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products. The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer.
1/16”
7" 1 1/4”
4 1/2”
All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner.
1 1/4”
Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages.
Mounting Sleeve 1/8” thk clear routed acrylic, Edges: Flame polished Mounting: Slides behind Sign Panel (Ref. Sheet 3.3)
3”
All materials used are to be as specified and/or meet or exceed all required local and national codes.
• Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment.
Wall Surface
Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications.
1/32” thk metal sheeting laminated to face of Mounting Sleeve
Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
ALTERNATE FABRICATION AREA
1/16”
5”
1/16” 1/4” 1/16” Routed Edge
2”
Firstname Lastname, Ed.D Front Elevation - Name Panel - Alternate Fabrication Scale: 1” = 1”
Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program
Felt Spacers (2) 1/32” thk, match thickness of VHB Tape or Rigid Mounting Plate
Name Copy 3M Controltac Plus Graphic Films Color: 150C-10 Matte White Type: Frutiger LT Std 45 Light Copy Height: Varies, Reference Sheet No. 3.7
Sheet Title
Mounting Sleeve
1/8”
A
Name Panel 1/4” thk solid matte acrylic with 1/16“ routed edge as shown Color: Gray (final color TBD) Edges: Flame polished Mounting: Laminated to Mounting Sleeve
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519
B
Section View Scale: 1” = 1”
Name Panel (Sign Types A2 and A4) Elevation Views - Alt. Fabrication Date
07.08.2013
Sheet No.
3.6_alt Copyright © 2012 AYERS | SAINT | GROSS
1 3/16”
1 1/4”
5 1/4” max. message length
Firstname Lastname
Graphic Layout - Name Panel Single Occupancy, Short Name Copy Height: 3/8” Tall Scale: 1” = 1”
No. Date
Revision
--
Various occupancy conditions and name lengths exist. When titles exist, title and last name must appear together on a line. Messages exceeding maximum message length must break to the next line. Notes These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products. The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer.
5/8”
7/8”
All materials used are to be as specified and/or meet or exceed all required local and national codes.
Firstname Lastname, Ed.D
Graphic Layout - Name Panel Single Occupancy, Long Name Copy Height: 3/8” Tall Scale: 1” = 1” Various occupancy conditions and name lengths exist. When titles exist, title and last name must appear together on a line. Messages exceeding maximum message length must break to the next line.
All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages. • Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment. Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications.
7 /16”
7/8”
Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
First Person, Title Second Person, Title
Graphic Layout - Name Panel Double Occupancy Copy Height: 1/4” Tall Scale: 1” = 1” Various occupancy conditions and name lengths exist. When titles exist, title and last name must appear together on a line. Messages exceeding maximum message length must break to the next line.
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519 Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
7 /16” 7 /16”
11/16”
Community College of Baltimore County Interior Signage Program
First Person, Title Second Person, Title Third Person, Title
Graphic Layout - Name Panel Triple Occupancy Copy Height: 1/4” Tall Scale: 1” = 1” Various occupancy conditions and name lengths exist. When titles exist, title and last name must appear together on a line. Messages exceeding maximum message length must break to the next line.
Sheet Title
Name Panel (Sign Types A2 and A4) Graphic Layouts Date
07.08.2013
Sheet No.
3.7 Copyright © 2012 AYERS | SAINT | GROSS
7" 3/4” OC
1/2”
5 3/8”
1/4” No. Date
Revision
1 3/8”
align
--
1 3/8”
ELECTRICAL CLOSET
5/8”
7/8”
7 3/4”
These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products.
Tactile Copy / Braille 1/32” thk with adhesive back Romark ADA Alternative Applique Material: Single-ply modified acrylic Finish: Matte non-glare Color: 3X1-307 Charcoal Gray Type: Frutiger LT Std 55 Roman Copy Height: 5/8” Tall Braille Process: Clear redundant raster bead braille
3/8” OC
5/8”
220
Notes
The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer. All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages.
Graphic Accent Etched and filled PMS 293C File Name: “L6.eps”
Wall Surface
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications. Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519
1/32” thk VHB Tape
Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program
Sign Panel 1/16” thk pre-finished aluminum laminated to 3/16” thk acrylic Finish: #220 Inline Edges and Corners: Eased Aluminum Edges: Brushed Acrylic Edges: Surface painted PMS 293C Mounting: VHB Tape to wall surface Wall Surface: Varies
Front Elevation - A5 Scale: 1” = 1”
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment.
Tactile Copy / Braille 1/32” thk with adhesive back Romark ADA Alternative Applique Material: Single-ply modified acrylic Finish: Matte non-glare Color: 3X1-307 Charcoal Gray Type: Frutiger LT Std 55 Roman Copy Height: 5/8” Tall Braille Process: Clear redundant raster bead braille
5 1/4” max. message length
A
• Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
Sheet Title
Sign Type A5 Elevation Views
B
Side View Scale: 1” = 1”
Date
07.08.2013
Sheet No.
3.8 Copyright © 2012 AYERS | SAINT | GROSS
8" 3/4” OC
1/2”
6 3/8”
1/4” No. Date
Revision
1 3/8”
align
--
1 3/8” 5/8”
7/8”
7/8”
7 3/4”
ELECTRICAL MECHANICAL OPERATIONS 6 1/4” max. message length
A
Front Elevation - A5B Scale: 1” = 1”
These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products.
Tactile Copy / Braille 1/32” thk with adhesive back Romark ADA Alternative Applique Material: Single-ply modified acrylic Finish: Matte non-glare Color: 3X1-307 Charcoal Gray Type: Frutiger LT Std 55 Roman Copy Height: 5/8” Tall Braille Process: Clear redundant raster bead braille
3/8” OC
5/8”
220
Notes
The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer. All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages.
Graphic Accent Etched and filled PMS 293C File Name: “L7.eps”
• Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment. Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications.
Wall Surface
Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
Tactile Copy / Braille 1/32” thk with adhesive back Romark ADA Alternative Applique Material: Single-ply modified acrylic Finish: Matte non-glare Color: 3X1-307 Charcoal Gray Type: Frutiger LT Std 55 Roman Copy Height: 5/8” Tall Braille Process: Clear redundant raster bead braille
Sign Panel 1/16” thk pre-finished aluminum laminated to 3/16” thk acrylic Finish: #220 Inline Edges and Corners: Eased Aluminum Edges: Brushed Acrylic Edges: Surface painted PMS 293C Mounting: VHB Tape to wall surface Wall Surface: Varies
B
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519
1/32” thk VHB Tape
Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program
Sheet Title
Sign Type A5B Elevation Views
Side View Scale: 1” = 1”
Date
07.08.2013
Sheet No.
3.9 Copyright © 2012 AYERS | SAINT | GROSS
7" 1/4”
center left to right
No. Date
Revision
--
Notes These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products.
varies per symbol (Ref. Sheet No. 3.8)
3/4”
All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages. • Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment. Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications.
Tactile Symbol 1/32” thk with adhesive back Romark ADA Alternative Applique Material: Single-ply modified acrylic Finish: Matte non-glare Color: 3X1-307 Charcoal Gray File Name: Varies per location, reference Message Schedule
RESTROOM
5/8”
The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer.
Wall Surface
1 1/4”
9 3/4”
6”
varies per symbol (Ref. Sheet No. 3.8)
Sign Panel 1/16” thk pre-finished aluminum laminated to 3/16” thk acrylic Finish: #220 Inline Edges and Corners: Eased Aluminum Edges: Brushed Acrylic Edges: Surface painted PMS 293C Mounting: VHB Tape to wall surface Wall Surface: Varies
Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519
1/32” thk VHB Tape
Tactile Copy / Braille 1/32” thk with adhesive back Romark ADA Alternative Applique Material: Single-ply modified acrylic Finish: Matte non-glare Color: 3X1-307 Charcoal Gray Type: Frutiger LT Std 55 Roman Copy Height: 5/8” Tall Braille Process: Clear redundant raster bead braille
Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program
Sheet Title
A
Front Elevation - B1 thru B10 - B3 (shown as typical) Scale: 3/4” = 1”
B
Side View Scale: 3/4” = 1”
Sign Types B1, B2, B3, B4, B5, B6, B7, B8, and B10 Elevation Views Date
07.08.2013
Sheet No.
3.10 Copyright © 2012 AYERS | SAINT | GROSS
center left to right
center left to right
No. Date
3”
2”
2”
center left to right
2”
center left to right
--
Notes
4”
4”
These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products.
3”
4”
Revision
The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer.
Alt. Layout - B1 Scale: 3/8” = 1”
RESTROOM
Alt. Layout - B2 Scale: 3/8” = 1”
B
center left to right
Alt. Layout - B4 Scale: 3/8” = 1”
Alt. Layout - B5 Scale: 3/8” = 1”
D
center left to right
center left to right
2” 4”
4”
4”
2”
2”
center left to right
C
All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages. • Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment. Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications. Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
2”
A
MEN
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519
4”
WOMAN
WOMEN LOCKER ROOM
All materials used are to be as specified and/or meet or exceed all required local and national codes.
Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program
MEN LOCKER ROOM
ELEVATOR
STAIRS
LIFT
Sheet Title
Sign Types B1, B2, B4, B5, B6, B7, B8, and B10 Graphic Layouts
E
Alt. Layout - B6 Scale: 3/8” = 1”
F
Alt. Layout - B7 Scale: 3/8” = 1”
G
Alt. Layout - B8 Scale: 3/8” = 1”
H
Alt. Layout - B10 Scale: 3/8” = 1”
Date
07.08.2013
Sheet No.
3.11 Copyright © 2012 AYERS | SAINT | GROSS
1’-6” 2” OC 1 1/4”
1’-2 1/8”
Reference Sheet No. 3.13 for Header Panel and Back Plate Construction Details Header Panel 9/16” thk pre-finished aluminum, milled as shown to create channel for Window Panel, alignment posts (6), and top edge to accept set screws (tap Header Panel to accept set screws (3) Finish: #220 Inline Edges and Corners: Eased Edges: Brushed Mounting: Magnetically attached to Back Plate w/ alignment posts (6) and set screws (3)
2 3/8” OC
11”
6”
align
2
1’-11”
3’-0”
These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products.
5/16” 1/4”
Threaded Studs Provide threaded studs as required for sign installation
Insert Header Panel, Window Panel, and Footer Panel must align to form a consistent edge profile, provide 45˚ bevel as shown on all edges of Header Panel, Window Panel and Footer Panel
001 Suite 003 011 Suite 012 Suite 013 Suite 014 Suite 015
Suite 103 Suite 105 120-156 131
3/8”
LEVEL 1 Career Center International Student Services Academic Advisement Center Disability Support Services Testing Center
Notes
Window Panel
Classroom & Academic Support Center
Revision
--
Floor Copy Etched and filled MP 10269 Type: Frutiger LT Std 65 Bold Copy Height: 4” Tall Graphic Accent Etched and filled PMS 293C File Name: “L4.eps”
LOWER LEVEL Office of Judicial Affairs Office of Public Safety Enrollment Services Admissions Office Bursar’s Office Financial Aid Registrar’s Office
No. Date
Back Plate 1/4” thk acrylic, routed to accept magnetic strips (3), drilled to accept alignment posts (6), and drilled to accept countersunk screws (3) for mounting Footer Panel Background Process: Surface painted, MP White Edges: Routed, finished smooth and painted PMS 293C Mounting Method: VHB Tape to Wall Surface Wall Surface: Varies
The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer. All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages. • Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment. Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications.
Screws (3)
Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
VHB Tape
Footer Panel Window Panel 3/16” thk clear matte acrylic, routed as shown to fit within channel created by Header and Footer Panels Edges and Corners: Eased Edges: Flame polished Mounting: Held in place within routed channel created by Header Panel and Footer Panel NOTE: Window Panel and Insert are accessed by removing Header Panel
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519
Wall Surface
B
Construction Detail - Footer Panel Scale: 1” = 1”
Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
2”
LEVEL 2 Student Success Center Reading & World Language
A
Front Elevation - D1 Scale: 1/4” = 1”
Suite 203 208
Insert & Copy 1/16” thk white matte lexan Digitally printed copy Color: Match PMS 419U Type: Frutiger LT Std 65 Bold and Frutiger LT Std 55 Roman Copy Height: 1/2” Tall
Footer Panel 5/16” thk pre-finished aluminum, routed as shown to create channel for Window Panel Finish: #220 Inline Edges and Corners: Eased Edges: Brushed Mounting: Screws to Back Plate
Community College of Baltimore County Interior Signage Program
Sheet Title
Sign Type D1 Elevation Views and Details
Date
07.08.2013
Sheet No.
3.12 Copyright © 2012 AYERS | SAINT | GROSS
EQ.
EQ.
1 1/2” OC Set Screws (3)
1 1/2”
1 1/2” OC
Set Screws (3)
EQ. EQ. EQ. EQ.
align
1”
2 1/2”
1”
2 1/2”
1”
Header Panel 9/16” thk pre-finished aluminum, milled as shown to create channel for Window Panel, alignment posts (6), and top edge to accept set screws (tap Header Panel to accept set screws (3) Finish: #220 Inline Edges and Corners: Eased align Edges: Brushed Mounting: Magnetically attached to 1/8” DIA Holes (6), drilled Back Plate w/ alignment posts (6) and to accept Alignment Posts (6) set screws (3) on Header Panel
High Strength Magnets (3) Back Plate is routed to accept Magnets for flush mounting of Header Panel
No. Date
Back Plate 1/4” thk acrylic, routed to accept magnetic strips (3), drilled to accept alignment posts (6), and drilled to accept countersunk screws (3) for mounting Footer Panel Background Process: Surface painted, MP White Edges: Routed, finished smooth and painted PMS 293C Mounting Method: VHB Tape to Wall Surface Wall Surface: Varies
High Strength Magnet Mounted to Back Plate 1/32” thk metal sheeting laminated to back of Header Panel
Threaded Studs Provide threaded studs as required for sign installation
Alignment Posts (6)
Revision
--
Notes These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products. The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer. All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages. • Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
2’-11 3/4”
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment.
Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
align
align
align
Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications.
High Strength Magnet Mounted to Back Plate
Wall Surface
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519
1/32” thk metal sheeting laminated to back of Header Panel VHB Tape
3/8”
Header Panel, Window Panel, and Footer Panel must align to form a consistent edge profile, provide 45˚ bevel as shown on all edges of Window Panel and Footer Panel
Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program
Window Panel 1/8” DIA Holes (3), drilled to accept Screws (3) to secure Footer Panel
align
Construction Detail - Back Plate Scale: 1/4” = 1”
Sign Type D1 Elevation Views and Details 5/16” 1/4”
1”
A
Sheet Title
Insert
B
Construction Detail - Header Panel Scale: 1” = 1”
Date
07.08.2013
Sheet No.
3.13 Copyright © 2012 AYERS | SAINT | GROSS
1’-6” 3 1/4”
3/4” Max. print area 1’-11” tall
2”
No. Date
Classroom & Academic Support Center
-Designer to provide full scale template in Adobe InDesign and/or Adobe Illustrator
2” 1’-11 5/8”
7/8” 7/8”
LOWER LEVEL Office of Judicial Affairs Office of Public Safety Enrollment Services Admissions Office Bursar’s Office Financial Aid Registrar’s Office LEVEL 1 Career Center International Student Services Academic Advisement Center Disability Support Services Testing Center LEVEL 2 Student Success Center Reading & World Language
Revision
Final Layout TBD
001 Suite 003 011 Suite 012 Suite 013 Suite 014 Suite 015
These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products. The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer.
Insert & Copy 1/16” thk white matte lexan Digitally printed copy Color: Match PMS 419U Type: Frutiger LT Std 65 Bold and Frutiger LT Std 55 Roman Copy Height: 1/2” Tall Contractor shall provide inserts as specified above for all D1 signs as part of this contract.
Following completion of this project, CCBC may choose to produce inserts in-house via black/white inkjet plotter on paper.
Suite 103 Suite 105 120-156
Notes
The following specifications should be followed by CCBC when producing inserts in-house via black/white inkjet plotter.:
All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages. • Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment. Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications. Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
Material: 35 lb. Heavyweight Inkjet Paper Copy Process: Inkjet, Match PMS 419U Typefaces: Frutiger LT Std 65 Bold and Frutiger LT Std 55 Roman
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519
131
Suite 203 208
Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program
Sheet Title
Max. print area 1’-11” tall
A
Graphic Layout - B1 - Insert Scale: 3/8” = 1”
Sign Type D1 Insert Graphic Layout
Date
07.08.2013
Sheet No.
3.14 Copyright © 2012 AYERS | SAINT | GROSS
No. Date
Revision
--
1’-2” Notes These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products. The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer.
201-222 Records & Registration Student Services
1’-2”
223-255 Counseling Center
1’-4”
201-222 Records & Registration Student Services
All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages. • Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment. Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications. Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
223-255 Counseling Center
201-222 Records & Registration Student Services
10”
Financial Aid Center and Additional Text
2’-0”
1’-2”
All materials used are to be as specified and/or meet or exceed all required local and national codes.
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519
Financial Aid Center and Additional Text
Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program
A
Front Elevation - D2A Scale: 1/4” = 1”
B
Front Elevation - D2B Scale: 1/4” = 1”
C
Front Elevation - D2C Scale: 1/4” = 1”
Sheet Title
Sign Types D2A, D2B, and D2C Elevation Views Date
07.08.2013
Sheet No.
3.15 Copyright © 2012 AYERS | SAINT | GROSS
1 1/2” OC
1”
1/4”
10 3/4”
No. Date
Revision
2 3/8” OC
--
Notes These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products. The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer.
2” OC
Graphic Accent Etched and filled PMS 293C File Name: “L5.eps”
1 1/2” OC
7/8”
1 1/4”
1 5/8”
201-222 Records & Registration Office of College Life & Judicial Services 223-255 Counseling Center
All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages.
Arrows and Copy 3M Controltac Plus Graphic Films Color: 150C-12 Matte Black Arrow Height: 7/8“ Tall Type: Frutiger LT Std 55 Roman Copy Height: 5/8” Tall, Reference Sheet No. 2.2 for additional information
• Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment. Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications.
Wall Surface
Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
Sign Panel 1/16” thk pre-finished aluminum laminated to 3/16” thk acrylic Finish: #220 Inline Edges and Corners: Eased Aluminum Edges: Brushed Acrylic Edges: Surface painted PMS 293C Mounting: VHB Tape to wall surface
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519
Financial Aid Center and Additional Text
1/32” thk VHB Tape
Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program
10 1/2” max. message length
Sheet Title
Sign Type D2A, D2B, and D2C Graphic Layout and Side View
A
Graphic Layout - D2A, D2B, and D2C Scale: 1/2” = 1”
B
Side View Scale: 1/2” = 1”
Date
07.08.2013
Sheet No.
3.16 Copyright © 2012 AYERS | SAINT | GROSS
3/4”
C
Plan View Scale: 1/4” = 1”
No. Date
Revision
--
5’-0” 5 3/4”
1/2”
1/2”
5 3/4”
Notes
Logo Graphics (2) Surface screened MP 10269 File Name: “L8.eps” Size: 4.5” x 1.75” Centered Left to Right Between Left Edge of Mounting Bracket and Mounting Rod, Center Top to Bottom within Area
Ceiling heights will vary from location to location, Contractor shall field cut Mounting Rods in the field as required to maintain 80” AFF clearance (Reference Sheet No. 4.4 for Mounting Elevation
Mounting Hardware (2) 1/2” dia aluminum Finish: Satin Mounting: Mechanical fasten to ceiling or ceiling deck, Contractor to verify ceiling conditions, no visible anchor bolts or additional fasteners will be accepted
4 1/2”
Disability Support S Testing Center International Stude
2 7/8”
1’-2”
1’-4 1/8”
The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer. All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner.
In cases where mounting must occur above a dropped finished ceiling, an escutcheon shall be used to match mounting hardware
1/8” 2”
1/8” TYP.
Mounting Rods (2) 1/8” dia aluminum, threaded on Mounting Bracket end Finish: Satin Mounting: Threaded through Mounting Bracket and into Sign Core
These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products.
Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages.
Sign Panels and Mounting Bracket must align to form a consistent edge profile
varies per location and ceiling condition
1”
Ceiling
• Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment. Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications. Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519 Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program Mounting Bracket 1/16” thk pre-finished aluminum, bend as shown in Section View, threaded to accept Mounting Rods Finish: #220 Inline Edges and Corners: Eased Edges: Brushed Mounting: Laminated to Mounting Core
A
Front Elevation and Section View - D3A Scale: 1/4” = 1”
Sign Panels (2) 1/16” thk clear matte acrylic Background Process: Second surface painted MP 10269 (between layers) Edges: Flame polished Mounting: Laminated to Mounting Core
Sign Core 1/2” thk sintra Background Process: Surface painted PMS 293C Edges: Routed, finished smooth and painted to match face Mounting: Threaded to accept Mounting Rods
Sheet Title
Sign Type D3A Elevation Views
Date
07.08.2013
Sheet No.
3.17 Copyright © 2012 AYERS | SAINT | GROSS
3/4”
No. Date
--
C
Plan View Scale: 1/4” = 1”
Notes These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products.
3’-4” 5 3/4”
1/2”
1/2”
The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer.
5 3/4”
All materials used are to be as specified and/or meet or exceed all required local and national codes.
Logo Graphics (2) Surface screened MP 10269 File Name: “L8.eps” Size: 4.5” x 1.75” Centered Left to Right Between Left Edge of Mounting Bracket and Mounting Rod, Center Top to Bottom within Area
Ceiling heights will vary from location to location, Contractor shall field cut Mounting Rods in the field as required to maintain 80” AFF clearance (Reference Sheet No. 4.4 for Mounting Elevation
All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner.
• Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
In cases where mounting must occur above a dropped finished ceiling, an escutcheon shall be used to match mounting hardware
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
center copy left to right
4 1/2”
1/8” 2”
1/8” TYP.
Mounting Rods (2) 1/8” dia aluminum, threaded on Mounting Bracket end Finish: Satin Mounting: Threaded through Mounting Bracket and into Sign Core
Mounting Hardware (2) 1/2” dia aluminum Finish: Satin Mounting: Mechanical fasten to ceiling or ceiling deck, Contractor to verify ceiling conditions, no visible anchor bolts or additional fasteners will be accepted
7”
Enrollment Office Mounting Bracket 1/16” thk pre-finished aluminum, bend as shown in Section View, threaded to accept Mounting Rods Finish: #220 Inline Edges and Corners: Eased Edges: Brushed Mounting: Laminated to Mounting Core
Copy (2 sets) 3M Controltac Plus Graphic Films Color: 150C-10 Matte White Type: Frutiger LT Std 55 Roman Copy Height: 2” Tall
Sign Panels (2) 1/16” thk clear matte acrylic Background Process: Second surface painted MP 10269 (between layers) Edges: Flame polished Mounting: Laminated to Mounting Core
Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages.
Sign Panels and Mounting Bracket must align to form a consistent edge profile
varies per location and ceiling condition
1”
Ceiling
9 1/8”
Revision
Sign Core 1/2” thk sintra Background Process: Surface painted PMS 293C Edges: Routed, finished smooth and painted to match face Mounting: Threaded to accept Mounting Rods
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment. Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications. Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519 Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program
Sheet Title
A
Front Elevation and Section View - D3B Scale: 1/4” = 1”
Sign Type D3B Elevation Views
Date
07.08.2013
Sheet No.
3.18 Copyright © 2012 AYERS | SAINT | GROSS
1”
Sign Panels and Mounting Bracket must align to form a consistent edge profile
No. Date
Wall Surface
--
Plan View Scale: 1/4” = 1”
C
Revision
Notes These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products.
2’-2 1/8” 2” 1/8”
1”
2’-0”
The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer.
8 3/4”
Accent Panels (2) 1/16” thk pre-finished aluminum Finish: #220 Inline Edges and Corners: Eased Edges: Brushed Mounting: Laminated to Mounting Core flush to wall surface
Office of Public Safety
Wall Surface
Sign Panels (2) 1/16” thk clear matte acrylic Background Process: Second surface painted MP 10269 (between layers) Edges: Flame polished Mounting: Laminated to Mounting Core Logo Graphics (2) Surface screened MP 10269 File Name: “L8.eps” Size: 1.5” x 1.75”
Front Elevation - D4 Scale: 1/4” = 1”
A
All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner.
Mounting Core 3/4” thk sintra Background Process: Surface painted PMS 293C Edges: Routed, finished smooth and painted to match face Mounting: Keyhole Hanging Assembly to Wall Surface - concealed by Accent Panels (2) Wall Surface: Varies
Copy (2 sets) 3M Controltac Plus Graphic Films Color: 150C-10 Matte White Type: Frutiger LT Std 55 Roman Copy Height: 2” Tall
1/8” 1/2”
9”
1/8”
All materials used are to be as specified and/or meet or exceed all required local and national codes.
Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages. • Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment. Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications.
B
Side View Scale: 1/4” = 1”
Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519
Center Left to Right within Area
2”
2”
Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
D
Graphic Layout - D4 Scale: 3/16” = 1”
align
5 1/2”
align
Office of Public Safety
3”
4”
Project Name
Community College of Baltimore County Interior Signage Program
Admissions
Sheet Title
Sign Type D4 Elevation Views and Graphic Layouts
E
Alt. Layout - D4 Scale: 3/16” = 1”
Date
07.08.2013
Sheet No.
3.19 Copyright © 2012 AYERS | SAINT | GROSS
1”
Wall Surface
Sign Panels and Mounting Bracket must align to form a consistent edge profile
Mounting Core 3/4” thk sintra Background Process: Surface painted PMS 293C Edges: Routed, finished smooth and painted to match face Mounting: Keyhole Hanging Assembly to Wall Surface - concealed by Accent Panels (2) Wall Surface: Varies
Plan View Scale: 1/2” = 1”
A
1’-2 1/8” 2”
1/8”
No. Date
--
Notes These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products.
1’-0” 1”
center left to right
Revision
The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer.
3 1/2”
1/8”
All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner.
Accent Panels (2) 1/16” thk pre-finished aluminum Finish: #220 Inline Edges and Corners: Eased Edges: Brushed Mounting: Laminated to Mounting Core
Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages. • Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment.
Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
Wall Surface
5”
11 3/4”
1’-0”
Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications.
Symbols (2 sets) 3M Controltac Plus Graphic Films Color: 150C-10 Matte White Copy Height: 2” Tall
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519 Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Sign Panels (2) 1/16” thk clear matte acrylic Background Process: Second surface painted MP 10269 (between layers) Edges: Flame polished Mounting: Laminated to Mounting Core
1/2”
Community College of Baltimore County Interior Signage Program
1/8”
Sheet Title
A
Front Elevation - D5 Scale: 1/2” = 1”
Logo Graphics (2) Surface screened MP 10269 File Name: “L8.eps” Size: 1.5” x 1.75” Center Left to Right within Area
Sign Type D5 Elevation Views
B
Side View Scale: 1/2” = 1”
Date
07.08.2013
Sheet No.
3.20 Copyright © 2012 AYERS | SAINT | GROSS
Section
MOUNTING ELEVATIONS
4
Copyright © 2012 AYERS | SAINT | GROSS
Wall conditions will vary from location to location and may include drywall, paneling, brick, wood, metal paneling, glass, concrete, etc.
Wall conditions will vary from location to location and may include drywall, paneling, brick, wood, metal paneling, glass, concrete, etc.
Contractor shall field verify wall conditions for each location and submit proposed mounting strategy for approval by Owner and Designer
Contractor shall field verify wall conditions for each location and submit proposed mounting strategy for approval by Owner and Designer
Contractor shall provide vinyl back plate for all glass-mounted locations. Vinyl back plate shall be a standard vinyl color, match the profile of the sign, and be mounted to same glass surface as sign.
Contractor shall provide vinyl back plate for all glass-mounted locations. Vinyl back plate shall be a standard vinyl color, match the profile of the sign, and be mounted to same glass surface as sign.
Contractor shall provide rigid back plate for all porous-surface locations. Rigid back plate shall be min. 0.1875” thk aluminum with countersunk hardware, paint edges to match Sign panel edges
Contractor shall provide rigid back plate for all porous-surface locations. Rigid back plate shall be min. 0.1875” thk aluminum with countersunk hardware, paint edges to match Sign panel edges
Contractor shall be responsible for identifying glass-mounted and porous-surface mounting locations during the Existing Conditions Survey
Contractor shall be responsible for identifying glass-mounted and porous-surface mounting locations during the Existing Conditions Survey
No. Date
Revision
--
Notes These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products. The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer. All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages. • Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment. Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications. Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
Tactile Copy Area
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519
60” AFF top of all signs
48”-60”
9” OC
60” AFF top of all signs
48”-60”
Tactile Copy Area
9” OC
Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program
Sheet Title
Sign Types A1, A2, A3, A4, A5, and A5B Mounting Elevations
A
Mounting Elevation - Sign Types A1, A2, A3, and A4 Scale: 3/4” = 1”
B
Mounting Elevation - Sign Types A5 and A5B Scale: 3/4” = 1”
Date
07.08.2013
Sheet No.
4.1 Copyright © 2012 AYERS | SAINT | GROSS
Wall conditions will vary from location to location and may include drywall, paneling, brick, wood, metal paneling, glass, concrete, etc. Contractor shall field verify wall conditions for each location and submit proposed mounting strategy for approval by Owner and Designer Contractor shall provide vinyl back plate for all glass-mounted locations. Vinyl back plate shall be a standard vinyl color, match the profile of the sign, and be mounted to same glass surface as sign.
No. Date
Revision
--
Contractor shall provide rigid back plate for all porous-surface locations. Rigid back plate shall be min. 0.1875” thk aluminum with countersunk hardware, paint edges to match Sign panel edges Notes
Contractor shall be responsible for identifying glass-mounted and porous-surface mounting locations during the Existing Conditions Survey
These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products. The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer. All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner.
Sign Face
Vinyl Back Plate
Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages.
Glass Surface
• Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment. Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications.
Tactile Copy Area
B
Mounting Sketch - Glass-Mounting Scale: NTS
Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519
60” AFF top of all signs
48”-60”
9” OC
Sign Face
Rigid Back Plate w/ Countersunk Screws
Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Wall Surface
Community College of Baltimore County Interior Signage Program
Sheet Title
Sign Types B1, B2, B3, B4, B5, B6, B7, B8, and B10 Mounting Elevation
A
Mounting Elevation - Sign Types B1, B2, B3, B4, B5, B6, B7, B8, and B10 Scale: 3/4” = 1”
C
Mounting Sketch - Porous-Surface Mounting Scale: NTS
Date
07.08.2013
Sheet No.
4.2 Copyright © 2012 AYERS | SAINT | GROSS
Wall conditions will vary from location to location and may include drywall, paneling, brick, wood, metal paneling, glass, concrete, etc.
Wall conditions will vary from location to location and may include drywall, paneling, brick, wood, metal paneling, glass, concrete, etc.
Contractor shall field verify wall conditions for each location and submit proposed mounting strategy for approval by Owner and Designer
Contractor shall field verify wall conditions for each location and submit proposed mounting strategy for approval by Owner and Designer
Contractor shall provide vinyl back plate for all glass-mounted locations. Vinyl back plate shall be a standard vinyl color, match the profile of the sign, and be mounted to same glass surface as sign.
Contractor shall provide vinyl back plate for all glass-mounted locations. Vinyl back plate shall be a standard vinyl color, match the profile of the sign, and be mounted to same glass surface as sign.
Contractor shall provide rigid back plate for all porous-surface locations. Rigid back plate shall be min. 0.1875” thk aluminum with countersunk hardware, paint edges to match Sign panel edges
Contractor shall provide rigid back plate for all porous-surface locations. Rigid back plate shall be min. 0.1875” thk aluminum with countersunk hardware, paint edges to match Sign panel edges
Contractor shall be responsible for identifying glass-mounted and porous-surface mounting locations during the Existing Conditions Survey
Contractor shall be responsible for identifying glass-mounted and porous-surface mounting locations during the Existing Conditions Survey
No. Date
Revision
--
Notes These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products. The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer. All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages.
201-222 Records & Registration Student Services
131
Suite 203 208
40”-70”
Suite 103 Suite 105 120-156
201-222 Records & Registration Student Services
201-222 Records & Registration Student Services
223-255 Counseling Center
223-255 Counseling Center
Financial Aid Center and Additional Text
Financial Aid Center and Additional Text
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications. Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519
70” AFF align with top of all signs
70” AFF align with graphic accent
LEVEL 2 Student Success Center Reading & World Language
001 Suite 003 011 Suite 012 Suite 013 Suite 014 Suite 015
Min. 5/8” Visual Character Area
Min. 5/8” Visual Character Area
40”-70”
Classroom & Academic Support Center
LEVEL 1 Career Center International Student Services Academic Advisement Center Disability Support Services Testing Center
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment.
2 LOWER LEVEL Office of Judicial Affairs Office of Public Safety Enrollment Services Admissions Office Bursar’s Office Financial Aid Registrar’s Office
• Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program
Sheet Title
Sign Types D1, D2A, D2B, and D2C Mounting Elevations
A
Mounting Elevation - Sign Type D1 Scale: 3/4” = 1”
B
Mounting Elevation - Sign Types D2A, D2B, D2C Scale: 3/4” = 1”
Date
07.08.2013
Sheet No.
4.3 Copyright © 2012 AYERS | SAINT | GROSS
Ceiling heights will vary from location to location, and may not be plumb and level
Contractor shall cut Mounting Rods in the field as required to maintain level 80” AFF clearance
Contractor shall cut Mounting Rods in the field as required to maintain level 80” AFF clearance
Ceiling conditions will vary from location to location and may include drop-ceiling tile systems, drywall, concrete, etc.,
Ceiling conditions will vary from location to location and may include drop-ceiling tile systems, drywall, concrete, etc.,
Contractor shall field verify ceiling conditions for each location and submit proposed mounting strategy for approval by Owner and Designer
Contractor shall field verify ceiling conditions for each location and submit proposed mounting strategy for approval by Owner and Designer
Contractor shall identify any locations that do not meet the minimum mounting requirements detailed below
Contractor shall identify any locations that do not meet the minimum mounting requirements detailed below
No. Date
Revision
--
Notes These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products. The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer.
Min. 3”
Min. 3”
Ceiling heights will vary from location to location, and may not be plumb and level
All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner.
Disability Support Services Testing Center International Student Services
Enrollment Office
Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages. • Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment. Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications.
80” AFF to bottom of sign
80” AFF to bottom of sign
Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519 Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program
Sheet Title
Sign Types D3A and D3B Mounting Elevation
A
Mounting Elevation - Sign Type D3A Scale: 3/4” = 1”
B
Mounting Elevation - Sign Type D3B Scale: 3/4” = 1”
Date
07.08.2013
Sheet No.
4.4 Copyright © 2012 AYERS | SAINT | GROSS
Ceiling heights will vary from location to location, and may not be plumb and level
Ceiling heights will vary from location to location, and may not be plumb and level
Contractor shall provide shims in the field as required to maintain level 80” AFF clearance
Contractor shall provide shims in the field as required to maintain level 80” AFF clearance
Wall conditions will vary from location to location and may include drywall, paneling, brick, wood, glass, metal panel, concrete, etc.
Wall conditions will vary from location to location and may include drywall, paneling, brick, wood, glass, metal panel, concrete, etc.
Contractor shall field verify wall conditions for each location and submit proposed mounting strategy for approval by Owner and Designer
Contractor shall field verify wall conditions for each location and submit proposed mounting strategy for approval by Owner and Designer
No. Date
Revision
--
Notes These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products. The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer. All materials used are to be as specified and/or meet or exceed all required local and national codes. All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages.
Office of Public Safety
• Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment. Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications.
80” AFF to bottom of sign
80” AFF to bottom of sign
Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519 Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Project Name
Community College of Baltimore County Interior Signage Program
Sheet Title
Sign Types D4 and D5 Mounting Elevations
A
Mounting Elevation - Sign Type D4 Scale: 3/4” = 1”
B
Mounting Elevation - Sign Type D5 Scale: 3/4” = 1”
Date
07.08.2013
Sheet No.
4.5 Copyright © 2012 AYERS | SAINT | GROSS
Contractor’s Scope of Work shall include removal of all existing Room Identification Signs and removal of all interfering items including but not limited to: signs, notices, posters, bulletin boards, etc. that fall within the removal area as described below.
Contractor’s Scope of Work shall include removal of all existing Key Destination / Wayfinding Signs (ceiling or wall mounted), and removal of all interfering items including but not limited to: signs, notices, posters, bulletin boards, etc. that fall within the removal area as described below.
Contractor shall coordinate directly with Owner for disposal or delivery of all removed items.
Contractor shall coordinate directly with Owner for disposal or delivery of all removed items.
Contractor’s Scope of Work shall also include restoration (patching, cleaning, painting, and repairing walls and ceilings) of any and all resultant damaged surfaces to match original material.
Contractor’s Scope of Work shall also include restoration (patching, cleaning, painting, and repairing walls and ceilings) of any and all resultant damaged surfaces to match original material.
Contractor shall identify any electrical conflicts and coordinate directly with w/ Owner.
Contractor shall identify any electrical conflicts and coordinate directly with w/ Owner.
Attain Owner’s approval prior to all restoration activities.
Attain Owner’s approval prior to all restoration activities.
No. Date
Revision
--
Notes These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products. The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer. All materials used are to be as specified and/or meet or exceed all required local and national codes.
4’-0”
All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages.
2’-0”
• Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
3’-0”
Existing Sign Area Removal and Wall Surface Restoration Area
5’-0”
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment.
Existing Sign Area Removal and Wall Surface Restoration Area
Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications. Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
20.0 sq. ft. 1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519
5.0 sq. ft.
Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
Community College of Baltimore County Interior Signage Program
3’-0”
3’-0”
Project Name
Sheet Title
Existing Signage Removal / Restoration Elevations
A
Removal / Restoration Elevation - Room Identification Signs Scale: 3/4” = 1”
B
Removal / Restoration Elevation - Key Destination / Wayfinding Signs Scale: 3/4” = 1” (Wall Mounted)
Date
07.08.2013
Sheet No.
4.6 Copyright © 2012 AYERS | SAINT | GROSS
Contractor’s Scope of Work shall include removal of all existing Key Destination / Wayfinding Signs (ceiling or wall mounted), and removal of all interfering items including but not limited to: signs, notices, posters, bulletin boards, etc. that fall within the removal area as described below.
Contractor’s Scope of Work shall include removal of all existing Key Destination / Wayfinding Signs (ceiling or wall mounted), and removal of all interfering items including but not limited to: signs, notices, posters, bulletin boards, etc. that fall within the removal area as described below.
Contractor shall coordinate directly with Owner for disposal or delivery of all removed items.
Contractor shall coordinate directly with Owner for disposal or delivery of all removed items.
Contractor’s Scope of Work shall also include restoration (patching, cleaning, painting, and repairing walls and ceilings) of any and all resultant damaged surfaces to match original material.
Contractor’s Scope of Work shall also include restoration (patching, cleaning, painting, and repairing walls and ceilings) of any and all resultant damaged surfaces to match original material.
No. Date
Contractor shall identify any electrical conflicts and coordinate directly with w/ Owner.
Contractor shall identify any electrical conflicts and coordinate directly with w/ Owner.
--
Attain Owner’s approval prior to all restoration activities.
Attain Owner’s approval prior to all restoration activities.
2’-0”
2’-0”
Revision
Notes These drawings are intended to illustrate design intent only, and should only be used as a general reference guideline. The Contrator bears sole responsibility for the performance and quality of the sign products.
2’-0”
The quality of fit and finish on the final product must meet or exceed the requirements of the design intent documents, sudsequently approved shop drawings, and other changes expressly authorized by Designer.
Existing Sign Area Removal and Ceiling Restoration Area
4’-0”
For ceiling mounted sign locations remove and restore both sides of corridor as shown
varies per location and ceiling condition
For flag mounted sign locations remove and restore wall surface that new sign will be located on only
For flag mounted sign locations remove and restore ceiling as shown above wall surface that new sign will be located on only
Existing Sign Area Removal and Ceiling Restoration Area
All locations shown are approximate. Final sign locations shall be determined during pre-installation walk-through with Owner. Messages and Locations shown in this document are for general reference only. Refer to message schedules and sign location plans for actual messages. • Catons_Rm_Number_BID.pdf • Dundalk_Rm_Number_BID.pdf • Essex_Rm_Number_BID.pdf
• Catons_Wayfinding_BID.pdf • Dundalk_Wayfinding_BID.pdf • Essex_Wayfinding_BID.pdf
• Catons_SLP_BID.pdf • Dundalk_SLP_BID.pdf • Essex_SLP_BID.pdf
• Add1_Catons_Rm_Number_BID.pdf • Add1_Catons_Wayfinding_BID.pdf
Contractor to verify wall surfaces and ceiling conditions to receive signage installation and provide recommended mounting attachment per wall surface and ceiling condition. Suspended signs shall be mounted in such a way as to not have excessive movement due to wind or HVAC equipment. Contractor is responsible for any and all existing signage removal and wall surface restoration coordination as described on Sheets No. 4.6 and 4.7 and within the Technical Specifications. Contractor shall obtain final electronic list of occupants for Name Panels from Owner. Contractor shall coordinate required information fields, file type, information style, and format directly with Owner.
For ceiling mounted sign locations remove and restore ceiling the entire width of corridor as shown
1040 Hull Street Suite 100 Baltimore, MD 21230 T: 410.347.8500 F: 410.347.8519 Project Number
Document Title
21134.00
Design Intent Documentation ISSUE FOR BID
60”
varies per location and ceiling condition
Existing Sign Area Removal and Wall Surface Restoration Area
All materials used are to be as specified and/or meet or exceed all required local and national codes.
Project Name
Community College of Baltimore County Interior Signage Program
Sheet Title
Existing Signage Removal / Restoration Elevations Date
A
Removal / Restoration Elevation - Key Destination / Wayfinding Signs Scale: 3/4” = 1” (Ceiling and Flag Mounted)
B
Removal / Restoration Refl. Ceiling Plan - Key Dest. / Wayfinding Signs Scale: 3/4” = 1” (Ceiling and Flag Mounted)
07.08.2013
Sheet No.
4.7 Copyright © 2012 AYERS | SAINT | GROSS