Smithsonian Front Royal Campus - Wayfinding Master Plan - 2015

Page 1

(select locations only)

Smithsonian Conservation Biology Institute

signage & wayfinding master plan - 10.07.2015

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

1


smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

2


table of contents INTRODUCTION 3 EXISTING CONDITIONS

7

WAYFINDING METHODOLOGY 13 DESIGN GUIDELINES 17 PROGRAMMING DOCUMENTS

42

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

1


smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

2


introduction The Signage and Wayfinding Master Plan provides guidance for the creation of a comprehensive family of ground-mounted exterior signs for the Post Area of the Smithsonian Conservation Biology Institute in Front Royal, Virginia. This document presents the strategic planning and programming process related to the signage system including design drawings, descriptions and placement criteria. It also guides the organization of sign messages and wayfinding methodology.

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

3


DEFINITION OF TERMS In order to have an effective Signage and Wayfinding

Signage

Master Plan, it is important to understand the

Signage refers to the system of signs on a campus that

interrelated nature of wayfinding and signage.

direct how people navigate through the environment. The signage system is designed to address image,

Wayfinding

brand, and messaging. Signage design is successful

Wayfinding is broad-reaching; it is an action that

when it carefully balances these dual aesthetic and

occurs between a user and a place, and it is affected

informational needs. Additionally, signage performs

by all visual and informational cues that help users

both directional and identification functions by

understand where they are. Although signage and

providing navigational guidance and identifying

wayfinding are often used together, they should not

destinations.

be thought of as interchangeable. Signage employs wayfinding messages, but it is one tool of the program. Wayfinding typically begins before a visitor arrives at campus. Pre-arrival wayfinding tools include websites, maps and personalized instructions. These tools set the tone and expectations for a visitor’s experience. Once on campus, the physical wayfinding system is expected to meet the same standard for quality interactions and information sharing. It should reinforce the institutional brand while delivering clear and simple navigational guidance.

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

4


PROCESS The signage and wayfinding master planning process

Programming

was structured through the following phases:

The Programming phase developed concurrently with Design. During Programming the design team worked

Observations and Research

with the Committee to establish a clear wayfinding

Concept Design

methodology to guide the rationale for exterior sign

Design Development

locations and sign messages.

Programming During this phase, the Steering Committee prioritized

Observations and Research

destinations and circulation paths, determined

During the Observations and Research phase, the

the criteria for defining primary destinations, and

design team toured the campus in order to gain a more

developed a protocol for messaging sequences. The

thorough understanding of user paths, circulation, and

Steering Committee also finalized critical decisions

parking. Summary observations were then shared with

about nomenclature and message criteria, such as the

the Steering Committee for confirmation. The Steering

relationship between parking and destinations.

Committee participated in a Workshop that further explored goals and objectives and informed design

Significant programming enhancements included the

solutions.

introduction of parking lot designations, the definition of public/restricted roadways within the campus,

Concept Design

the establishment of the preferred entry and arrival

The design team prepared concepts based on the design

sequence for visitors, buses, and deliveries, and the

direction established for the previously-implemented

designation of Gate 2 as the primary visitor arrival.

building identification signs, and the research, goals and objectives identified for the project. The design team presented concepts to the Steering Committee for feedback and response, and the committee provided guidance that resulted in schematic refinements. Design Development After receiving approval of the concept design, the design team revised, refined, and expanded the concept design to encompass the entire family of signs. These were synthesized into a design framework for the final signage and wayfinding solutions. Working with the Steering Committee, the team finalized critical decisions about design details and refined the dimensions, materials, and typography.

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

5


smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

6


existing conditions To better understand the current signage and wayfinding strategies on campus, the design team analyzed the campus setting, circulation patterns, and sign types. The qualitative and quantitative information gathered during this phase is represented in the images that follow. Observations in this section were reviewed and confirmed by the steering committee.

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

7


CAMPUS GATEWAYS Observations

Recommendations

Gateway signage is not in scale with adjacent gateway elements — walls, landscaping, fences, etc.

Messages are too small to read at the speed and distance for those passing in vehicles.

Design cohesive gateway elements as part of the gates 2 and 3 expansion projects. Integrate signage elements with other gateway elements.

Delete “National Zoological Park” from the sign.

The use of “National Zoological Park” as part of the sign message may give the appearance of a public non-restricted facility.

Reference Smithsonian brand standards for acceptable logo usage.

Arrival - Gate 2

Arrival - Gate 3

Campus Identification- Gate 2

Ancillary Signage - Gate 2

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

8


VEHICULAR DIRECTIONAL SIGNS Observations

Recommendations

Carved wooden signs require regular maintenance.

Directional signage for vehicular traffic contains too many messages for driving decisions.

Signs should be limited to information critical to a motorist’s next decision.

Messages are too small to read at the speed and distance for those passing in vehicles.

Text should be appropriately sized and placed for legibility.

Little guidance is given to visitors at key decision points (i.e., points that require a motorist to turn or continue on a path).

Vehicular information at key decision points should direct visitors to parking destinations where more detailed wayfinding signage will be provided.

Arrows are illegible and confusing.

Directional / Informational

Sign Detail

Directional / Regulatory

Directional

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

9


BUILDING IDENTIFICATION SIGNS Observations

Recommendations

Continue to replace older building identification signs with new design standard.

Develop a smaller building identification sign type for secondary destinations.

New building identification signs have been implemented on portions of the campus in conjunction with master plan construction projects.

Old signs remain on other parts of campus.

New sign use durable, low-maintenance materials, and accommodate a panel change if required.

Newly Implemented Sign - Dining Hall

Newly Implemented Sign - Residence & Meeting Center

Older Sign - Dormitory

Outdated Sign - Grounds & Farm Unit

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

10


MISCELLANEOUS SIGNS Observations

Recommendations

Regulatory signs are old and showing damage and wear to both structure and paint.

Investigate replacing regulatory signs as funds become available to match the new sign system.

"Authorized Personnel" messages are inconsistently applied from sign to sign.

Replace street signs with new sign type as indicated in Design Guidelines.

Several street identification signs are leaning and not level.

Temporary signs are used for wayfinding.

Temporary sign should be used sparingly – improvements to the wayfinding system should minimize the need for temporary messaging.

An assortment of inconsistent sign types distracts from the campus image and increases confusion.

Temporary Event Sign

Donor Recognition Sign

Directional / Regulatory

Street Sign

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

11


smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

12


wayfinding methodology A clear wayfinding methodology simplifies navigation through adherence to a consistent framework of destinations, nomenclature, and sequencing. Through the course of the project, several campus-wide determinations were made to aid campus navigation.

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

13


WAYFINDING METHODOLOGY The following high-level determinations were approved by the Steering Committee and subsequently served as the basis for the overall campus wayfinding methodology. These principles informed decisions regarding sign placement, content, message sequencing, and message locations. 1.

Defining Key Destinations

2.

Identifying and Lettering Visitor Parking Lots

3.

Defining the Main Path of Travel

4.

Sign Family Development

1. Defining Key Destinations

3. Defining the Main Path of Travel

The first step in developing the new wayfinding

Another key component to the project was identifying

methodology involved working with the Committee

a safe primary path of travel for the public. Because of

to define the key visitor destinations. The six key

the sensitivity of the research, it was important to create

destinations to this program include:

a sense of safety and accessibility to the various public

Academic Center

portions of the site for visitors, service, buses, and

Administration

deliveries.

Auditorium

Dining Hall

4. Sign Family Development

NEON

The final key component of the program was the

Residence & Meeting Center

development of a series of sign types designed to reinforce the various elements of the wayfinding

2. Identifying and Lettering Visitor Parking Lots

methodology.

An important addition to the program includes the introduction of a lot lettering system (labeled A

The following diagram summarizes the key components

through E) to aid on-site and pre-arrival wayfinding.

of the wayfinding methodology.

Motorists navigating to their destination must determine where to park. Preferred parking locations were defined for each key destination.

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

14


St re e

x 4x x

EY

5x

LL DA B IR RE

SE

AR

CH

DR

IV

E

WAYFINDING METHODOLOGY E RIV

Accessible Parking SLA

TE H

A

ILL D

Other Buildings

RIV

E

AUD

ITOR

Sh e

Parking

E et Tit Si xter le Fi gn ior na L l S oc Da te ub atio 04 m n .0 itt Pl 9. 20 al an 1

M

je c

Visitor Parking

S t OF CBI Nam e EO W Pr ay oj fin ec d t N in o. g S : 0 ig 87 nag 01 e 07

r be OAD

ER EAD

8. 00

CONSERVATION DRIV E

Key Destinations

Pr o

E

IN.

Main Path of Travel

um

ADM

RIV

tN

ND

je c

TIO

33

TRA

LON GHI LL R OAD

INIS

AD

HD RC SEA RE

ADM

E RO

Pr o

VIC

21

SER

10 Su 40 Ba ite Hu T: ltim 10 ll S tre F: 41 or 0 et 41 0.3 e, 0. 47 MD Do 34 .8 2 cu 7. 50 12 m 85 0 3 en 0 tT 19 itl e

Map Key

IUM

ION D

RIVE

E TE TIO

B

G CE

NTE

E

R DR

FER

RE

TC

IRC

LE

IVE

DIN HALING L

ND

Parking

& M RESID EET ENC ING E CEN TER

RIV

E

FAR

MR

OAD

GA

ININ

VA

Parking WE

MM

ER R

Parking

OAD

E

VE

Parking Reference Gate 2 and 3 Improvement Project documents for proposed signage at Gates 2 and 3

G ININ TRA

WE

MM

ER

RO

AD

T CEN

C

RI ER D

ER NS CO

ARCH

TRA

RESE

HO

US

DRIV

RVAT

NEO

CONSE

N

CON

SER

ACA CENDEMIC TER

VAT

ION

DRI

VE

Bus Drop-Off & Deliveries

D

Reference Gate 2 and 3 Improvement Project documents for proposed signage at Gates 2 and 3

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

15


16


design guidelines The goal of the Signage and Wayfinding Master Plan is to create a uniform family of signs to convey clear directional messages to visitors. This goals comprises both functional and aesthetic concerns – the need for a signage program that builds brand identity and for a wayfinding system that efficiently moves people through the publicly-accessible Post Area. An appropriate hierarchy of sign types guides visitors to their final destinations. Each sign type serves a unique and important function.

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

17


GRAPHIC STANDARDS

T1 - Minion Pro Regular ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz 1234567890 T2 - Minion Pro Semi-bold A B C DEF G H I J K L M NOPQRSTU V W XYZ ab c d ef g hijk l m n op qr stu v w xyz 1234567 8 9 0

P1

P2

PAINT 1 Matthews MP03078, semi-gloss

V1

PAINT 2 Matthews MP04515, semi-gloss

V2

VINYL 1 3M Custom Color - Match P1 High Intensity Grade Prismatic Reflective Sheeting

P3

P4

PAINT 3 Matthews MP05575, semi-gloss

PAINT 4 MP TBD

A

B

C

D

E

F

H

J

K

L

M

S

VINYL 2 3M 680-10 High Intensity Grade Prismatic Reflective Sheeting

LEFT ARROW

UP-LEFT ARROW

STRAIGHT ARROW

UP-RIGHT ARROW

RIGHT ARROW

(circle denotes arrow size)

(circle denotes arrow size)

(circle denotes arrow size)

(circle denotes arrow size)

(circle denotes arrow size)

P STRAIGHT-LEFT ARROW

STRAIGHT-RIGHT ARROW PARKING SYMBOL

(circle denotes arrow size)

(circle denotes arrow size)

A

B

C

D

E

i

F

G

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

18

G


GRAPHIC STANDARDS PROJECT SITE IDENTIFICATION LOGO (PER SMITHSONIAN BRAND STANDARDS)

Smithsonian Conservation Biology Institute PROJECT SITE IDENTIFICATION LOGO (per Smithsonian Brand Standards)

CO-BRANDED BUILDING IDENTIFICATION (SELECT LOCATIONS ONLY)

CO-BRANDED BUILDING IDENTIFICATION (select locations only)

Smithsonian Conservation Biology Institute

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

19


SIGN FAMILY

4'-4"

4'-4"

4'-4"

Administration Auditorium

Academic Center Dining Hall NEON Residence & Meeting Center

7'-10 1/2"

Parking Lot C

VDR.2

VDR.1

SCALE: 1/4” = 1’-0”

Parking Lots D-E Dining Hall NEON

6'-6"

Vehicular Directional Sign - Medium

Vehicular Directional Sign - Large

Accessible Parking & Deliveries for Administration

5'-1 1/2"

VDR.3

Vehicular Directional Sign - Small

4'-4"

4'-4"

7'-10 1/2"

Administration Auditorium Academic Center Dining Hall Residence & Meeting Center

Accessible Parking & Deliveries for Administration 6'-6"

Authorized Vehicles Beyond this Point

SCALE: 1/4” = 1’-0”

VDR.1R

Vehicular Directional Sign - Large (with regulatory information)

Authorized Vehicles Beyond this Point

VDR.2R

Vehicular Directional Sign - Medium (with regulatory information)

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

20


SIGN FAMILY

4'-4"

P

4'-0"

PARKING

3'-0"

Lot A R AC ET R AC K HILL

6'-6"

4'-4"

PRK.1

SCALE: 1/4” = 1’-0”

T H E WE M M E R HOUSE

3'-9"

BLD.1

Parking Lot Sign

BLD.2

Building Identification Sign - Large

Building Identification Sign - Small

1'-6"

3'-0"

Authorized Vehicles Beyond this Point

9'-2"

SLATE HILL DR

8'-9"

4'-4"

Authorized Vehicles Beyond this Point 3'-2 1/2"

SCALE: 1/4” = 1’-0”

REG.1

Regulatory Information Sign - Type A

REG.2

Regulatory Information Sign - Type B

STR.1

Street Identification Sign (post included)

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

21


SIGN TYPE: VDR.1 Vehicular Directional Sign – Large

5”

Refer to pages 33 and 34 for general specifications describing call-outs

PLAN VIEW

Refer to pages 35 - 40 for detailed information on graphic panel layouts for all sign types

4’-4” 2”

4’-0”

2”

3’-8” Visible Message Area

5’-10” Visible Message Area

A

B

Academic Center Dining Hall NEON Residence & Meeting Center

C

1’-8”

0.5”

7’-10.5”

6’-2”

Administration Auditorium

POSTS SHALL BE MIN. 1’-8” FROM BOTTOM OF SIGN PANEL TO HIGHEST POINT OF GRADE. ONE POST MAY NEED TO BE LONGER TO ACCOMODATE GRADE CHANGE. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL LOCATIONS FOR GRADE CHANGE. BREAK-AWAY FOOTER, BELOW GRADE SIZE AND DEPTH AS REQUIRED BY STRUCTURAL ENGINEER

ELEVATION VIEW Scale: 3/4” = 1’-0”

SECTION VIEW

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

22


SIGN TYPE: VDR.2 Vehicular Directional Sign – Medium

5”

Refer to pages 33 and 34 for general specifications describing call-outs

PLAN VIEW

Refer to pages 35 - 40 for detailed information on graphic panel layouts for all sign types

4’-4” 2”

4’-0”

2”

3’-8” Visible Message Area

4’-5.5” Visible Message Area

4’-9.5”

B

Parking Lots D-E Dining Hall NEON

C

1’-8”

0.5”

6’-6”

Parking Lot C

A

POSTS SHALL BE MIN. 1’-8” FROM BOTTOM OF SIGN PANEL TO HIGHEST POINT OF GRADE. ONE POST MAY NEED TO BE LONGER TO ACCOMODATE GRADE CHANGE. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL LOCATIONS FOR GRADE CHANGE. BREAK-AWAY FOOTER, BELOW GRADE SIZE AND DEPTH AS REQUIRED BY STRUCTURAL ENGINEER

ELEVATION VIEW Scale: 3/4” = 1’-0”

SECTION VIEW

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

23


SIGN TYPE: VDR.3 Vehicular Directional Sign – Small

5”

Refer to pages 33 and 34 for general specifications describing call-outs

PLAN VIEW

Refer to pages 35 - 40 for detailed information on graphic panel layouts for all sign types

4’-4” 2”

4’-0”

2”

3’-8” Visible Message Area

3’-1” Visible Message Area

5’-1.5”

3’-5”

A

Accessible Parking & Deliveries for Administration

B

1’-8”

0.5”

C

POSTS SHALL BE MIN. 1’-8” FROM BOTTOM OF SIGN PANEL TO HIGHEST POINT OF GRADE. ONE POST MAY NEED TO BE LONGER TO ACCOMODATE GRADE CHANGE. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL LOCATIONS FOR GRADE CHANGE. BREAK-AWAY FOOTER, BELOW GRADE SIZE AND DEPTH AS REQUIRED BY STRUCTURAL ENGINEER

ELEVATION VIEW Scale: 3/4” = 1’-0”

SECTION VIEW

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

24


SIGN TYPE: VDR.1R Vehicular Directional Sign – Large (with regulatory information)

5”

Refer to pages 33 and 34 for general specifications describing call-outs

PLAN VIEW

Refer to pages 35 - 40 for detailed information on graphic panel layouts for all sign types

4’-4” 2”

4’-0”

2”

1’-8”

4’-5.5” Visible Message Area 12” Visible Message Area

0.5”

1’-4”

0.5”

7’-10.5”

4’-9.5”

3’-8” Visible Message Area

Administration Auditorium Academic Center Dining Hall Residence & Meeting Center

Authorized Vehicles Beyond this Point

A

B

C

B

D

POSTS SHALL BE MIN. 1’-8” FROM BOTTOM OF SIGN PANEL TO HIGHEST POINT OF GRADE. ONE POST MAY NEED TO BE LONGER TO ACCOMODATE GRADE CHANGE. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL LOCATIONS FOR GRADE CHANGE. BREAK-AWAY FOOTER, BELOW GRADE SIZE AND DEPTH AS REQUIRED BY STRUCTURAL ENGINEER

ELEVATION VIEW Scale: 3/4” = 1’-0”

SECTION VIEW

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

25


SIGN TYPE: VDR.2R Vehicular Directional Sign – Medium (with regulatory information)

5”

Refer to pages 33 and 34 for general specifications describing call-outs

PLAN VIEW

Refer to pages 35 - 40 for detailed information on graphic panel layouts for all sign types

4’-4” 2”

4’-0”

2”

3’-8” Visible Message Area

3’-1” Visible Message Area

Accessible Parking & Deliveries for Administration

6’-6”

3’-5”

A

B

1’-8”

12” Visible Message Area

0.5”

1’-4”

0.5”

C

Authorized Vehicles Beyond this Point

B

D

POSTS SHALL BE MIN. 1’-8” FROM BOTTOM OF SIGN PANEL TO HIGHEST POINT OF GRADE. ONE POST MAY NEED TO BE LONGER TO ACCOMODATE GRADE CHANGE. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL LOCATIONS FOR GRADE CHANGE. BREAK-AWAY FOOTER, BELOW GRADE SIZE AND DEPTH AS REQUIRED BY STRUCTURAL ENGINEER

ELEVATION VIEW Scale: 3/4” = 1’-0”

SECTION VIEW

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

26


SIGN TYPE: PRK.1 Parking Lot Sign

5”

Refer to pages 33 and 34 for general specifications describing call-outs

PLAN VIEW

Refer to pages 35 - 40 for detailed information on graphic panel layouts for all sign types

4’-4” 2”

2”

4’-0”

3’-1” Visible Message Area

P

A

PA R K I NG

B

LOT

A

C

1’-8”

0.5”

1’-4”

0.5”

6’-6”

3’-5”

3’-8” Visible Message Area

POSTS SHALL BE MIN. 1’-8” FROM BOTTOM OF SIGN PANEL TO HIGHEST POINT OF GRADE. ONE POST MAY NEED TO BE LONGER TO ACCOMODATE GRADE CHANGE. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL LOCATIONS FOR GRADE CHANGE. BREAK-AWAY FOOTER, BELOW GRADE SIZE AND DEPTH AS REQUIRED BY STRUCTURAL ENGINEER

ELEVATION VIEW Scale: 3/4” = 1’-0”

SECTION VIEW

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

27


SIGN TYPE: BLD.1 Building Identification Sign – Large

4”

Refer to pages 33 and 34 for general specifications describing call-outs

PLAN VIEW

Refer to pages 35 - 40 for detailed information on graphic panel layouts for all sign types

3’-11.75” 1”

3’-9.75”

1”

2’-2.75” Visible Message Area

E

R ACET R AC K H I LL

B J C

1’-8.75”

0.5”

4’-4”

2’-6.75”

3’-5.75” Visible Message Area

POSTS SHALL BE MIN. 1’-8” FROM BOTTOM OF SIGN PANEL TO HIGHEST POINT OF GRADE. ONE POST MAY NEED TO BE LONGER TO ACCOMODATE GRADE CHANGE. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL LOCATIONS FOR GRADE CHANGE. DIRECT-BURIAL FOOTER, BELOW GRADE SIZE AND DEPTH AS REQUIRED BY STRUCTURAL ENGINEER

ELEVATION VIEW Scale: 3/4” = 1’-0”

SECTION VIEW

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

28


SIGN TYPE: BLD.2 Building Identification Sign – Small

4”

Refer to pages 33 and 34 for general specifications describing call-outs

PLAN VIEW

Refer to pages 35 - 40 for detailed information on graphic panel layouts for all sign types

3’-0” 1”

2’-10”

1”

1’-8.75”

1’-7.75” Visible Message Area

3’-9”

E

THE W EMMER HOUSE

B J C

0.5”

1’-11.75”

2’-6” Visible Message Area

POSTS SHALL BE MIN. 1’-8” FROM BOTTOM OF SIGN PANEL TO HIGHEST POINT OF GRADE. ONE POST MAY NEED TO BE LONGER TO ACCOMODATE GRADE CHANGE. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL LOCATIONS FOR GRADE CHANGE. DIRECT-BURIAL FOOTER, BELOW GRADE SIZE AND DEPTH AS REQUIRED BY STRUCTURAL ENGINEER

ELEVATION VIEW Scale: 3/4” = 1’-0”

SECTION VIEW

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

29


SIGN TYPE: REG.1 Regulatory Informational Sign – Type A

5”

Refer to pages 33 and 34 for general specifications describing call-outs

PLAN VIEW

Refer to pages 35 - 40 for detailed information on graphic panel layouts for all sign types

4’-4” 2”

4’-0”

2”

12” Visible Message Area

A

Authorized Vehicles Beyond this Point

B

D

0.5” 1’-8”

3’-2.5”

1’-6”

3’-8” Visible Message Area

POSTS SHALL BE MIN. 1’-8” FROM BOTTOM OF SIGN PANEL TO HIGHEST POINT OF GRADE. ONE POST MAY NEED TO BE LONGER TO ACCOMODATE GRADE CHANGE. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL LOCATIONS FOR GRADE CHANGE. BREAK-AWAY FOOTER, BELOW GRADE SIZE AND DEPTH AS REQUIRED BY STRUCTURAL ENGINEER

ELEVATION VIEW Scale: 3/4” = 1’-0”

SECTION VIEW

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

30


SIGN TYPE: REG.2 Regulatory Information Sign – Type B

2”

Refer to pages 33 and 34 for general specifications describing call-outs

PLAN VIEW

Refer to pages 35 - 40 for detailed information on graphic panel layouts for all sign types

1’-6” EQ.

2”

EQ.

Authorized Vehicles Beyond this Point

G

7’-0”

9’-2”

2’-0”

2”

F

BREAK-AWAY FOOTER, BELOW GRADE SIZE AND DEPTH AS REQUIRED BY STRUCTURAL ENGINEER

ELEVATION VIEW Scale: 3/4” = 1’-0”

SIDE VIEW

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

31


SIGN TYPE: STR.1 Street Identification Sign (post included)

Refer to pages 33 and 34 for general specifications describing call-outs Refer to V-DOT Guidelines for detailed information on graphic panel layouts

3’-0” 2”

EQ.

4”

5”

EQ.

SLATE HILL DR

I

8’-0”

8’-9”

H

BREAK-AWAY FOOTER, BELOW GRADE SIZE AND DEPTH AS REQUIRED BY STRUCTURAL ENGINEER

ELEVATION VIEW Scale: 3/4” = 1’-0”

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

32


GENERAL SPECIFICATIONS – (A - E) The following specifications are defined for all sign types and identified with corresponding drawing labels.

A B C A D B E C F D A G E B H F C I G D J A E H B F I C G J D A H E B I F C J G D E H FI G J

SIGN FRAME UNIT Material: 2" x 4" x 0.25" thk aluminum sign frame unit (sides and top) w/ 1" x 4" back cut aluminum plate cross brace (bottom) - all corners shall be welded and ground smooth and painted to match face Finish: Weather resistant flouro-polymer finish - P1 Mounting: Below grade break-away footer, size and depth as required by structural engineer Note: Assembly is drilled to accept tamper resistant, flush mounted stainless steel anchor screws REMOVABLE BEVEL FRAME UNIT Material: 2" x 2" x 0.25" thk removable beveled aluminum sign frame unit (four-sides) - all corners shall be mitered and have smooth, tight tolerances Finish: Weather resistant flouro-polymer finish - P1 Mounting: Mechanically fastened to Sign Frame Unit with tamper resistant, flush mounted stainless steel anchor screws, paint to match Note: Removable Bevel Frame Unit holds sign panel in place SIGN PANEL Material: 48" x 72" x 0.25" thk aluminum sign panel Finish: Weather resistant flouro-polymer finish - P3 Graphic Border Process: Weather resistant flouro-polymer finish - P2 Copy / Symbol Process: Applied reflective vinyl - V1 Mounting: Held in place by Removable Bevel Frame Unit - provide soft neoprene gasket between components Note: Some panels are double-sided, reference Sign Message Schedule REGULATORY PANEL Material: 48" x 16" x 0.25" thk aluminum sign panel Finish: Weather resistant flouro-polymer finish - P4 Copy / Symbol Process: Applied reflective vinyl - V2 Mounting: Held in place by Removable Bevel Frame Unit - provide soft neoprene gasket between components Note: Some panels are double-sided, reference Sign Message Schedule SIGN FRAME UNIT Material: 1" x 4" back cut aluminum sign frame unit (sides and top) w/ 0.5” x 4” back cut aluminum plate cross brace (bottom) - all corners shall be welded and ground smooth and painted to match face Finish: Weather resistant flouro-polymer finish - P1 Mounting: Below grade direct-burial footer, size and depth as required by structural engineer Note: Assembly is drilled to accept tamper resistant, flush mounted stainless steel anchor screws

H I J

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

33


A B

GENERAL SPECIFICATIONS – (F - J) C A The following specifications are defined for all sign types and identified with corresponding drawing labels. D B E C A F D B A G E C B F H D C G AI E D B J H F E CI G F D J H G E I F H J G I J H I J

SIGN POST Material: 2" x 2" x 0.25" thk square aluminum sign post - cap top Finish: Weather resistant flouro-polymer finish - P1 Mounting: Below grade break-away footer, size and depth as required by structural engineer Note: Assembly is drilled to accept tamper resistant, flush mounted stainless steel anchor screws SIGN PANEL Material: 18" x 24" x 0.125" thk aluminum sign panel Finish: Weather resistant flouro-polymer finish - P3 Graphic Border Process: Weather resistant flouro-polymer finish - P2 Copy / Symbol Process: Applied reflective vinyl - V1 Mounting: Screws to sign post with tamper resistant stainless steel fasteners SIGN POST Material: 2" x 2" x 0.25" thk round aluminum sign post Finish: Weather resistant flouro-polymer finish - P1 Mounting: Below grade break-away footer, size and depth as required by structural engineer ADDRESS PANEL ASSEMBLY Material: 36" x 4" x 0.125" thk aluminum address panel(s) Finish: Applied high intensity reflective vinyl background - green Copy Process: Applied high intensity reflective vinyl - bright white Mounting: Screws to sign post with approved sign post cap assembly DIMENSIONAL LETTERS Material: 0.1875" thk aluminum letters Finish: Weather resistant flouro-polymer finish - P1 Mounting: VHB tape to sign panel Reference Shop Drawings “00106777-R1_SmithsonianConservation_ShopDrawingMarkUps_20121108_ response.pdf ” for additional construction details and specifications

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

34


GRAPHIC PANEL LAYOUTS: TYPICAL VEHICULAR DIRECTIONAL – SINGLE-ARROW CONFIGURATION

3 3/4”

line spacing between single-line messages

line spacing between double-line messages

Administration Auditorium Academic Center Dining Hall Residence & Meeting Center

area covered by frame - typical

2 1/2”

5 3/4”

4 3/4”

5”

1’-3”

CL

TYPICAL GRAPHIC LAYOUT Sign Types VDR.1, VDR.2, VDR.3, VDR.1R, VDR.2R TYPEFACE: T1 MAX. LINE LENGTH SHALL NOT BE WITHIN 2” OF BORDER

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

35


GRAPHIC PANEL LAYOUTS: TYPICAL VEHICULAR DIRECTIONAL – MULTI-ARROW CONFIGURATION

11”

Parking Lot C

area covered by frame - typical

CL

Parking Lots D-E Dining Hall TYPICAL GRAPHIC LAYOUT Sign Types VDR.1, VDR.2, VDR.3, VDR.1R, VDR.2R TYPEFACE: T1 MAX. LINE LENGTH SHALL NOT BE WITHIN 2” OF BORDER

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

36


GRAPHIC PANEL LAYOUTS: TYPICAL PARKING LOT SIGN

3”

P PA R K I NG LOT

A

area covered by frame - all sides

9”

6”

9”

1’-5”

CL

TYPICAL GRAPHIC LAYOUT Sign Types PRK.1 TYPEFACE: T2 MAX. LINE LENGTH SHALL NOT BE WITHIN 2” OF BORDER

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

37


GRAPHIC PANEL LAYOUTS: TYPICAL LARGE IDENTIFICATION SIGN AND CO-BRANDED ALT.

area covered by frame - all sides

3”

R ACETR AC K HI LL

EQ.

7 1/2”

EQ.

CL

TYPICAL GRAPHIC LAYOUT Sign Types BLD.1 TYPEFACE: T2 MAX. LINE LENGTH SHALL NOT BE WITHIN 2” OF BORDER

ACADEM IC CE NTER

area covered by frame - all sides

EQ.

6”

3”

EQ.

CL

ALTERNATE GRAPHIC LAYOUT - CO-BRANDED BUILDING ID Sign Types BLD.1 TYPEFACE: T2 MAX. LINE LENGTH SHALL NOT BE WITHIN 2” OF BORDER

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

38


GRAPHIC PANEL LAYOUTS: TYPICAL SMALL IDENTIFICATION SIGN

area covered by frame - all sides

2”

T H E W EM M E R HOU SE

EQ.

5 1/2”

EQ.

CL

TYPICAL GRAPHIC LAYOUT Sign Types BLD.2 TYPEFACE: T2 MAX. LINE LENGTH SHALL NOT BE WITHIN 2” OF BORDER

Smithsonian Conservation Biology Institute

area covered by frame - typical

2 1/2”

Welcome to

1’-3”

3 3/4”

1’-1/2”

CL

UNIQUE GRAPHIC LAYOUT Sign Location 101 TYPEFACE: T1 MAX. LINE LENGTH SHALL NOT BE WITHIN 2” OF BORDER

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

39


GRAPHIC PANEL LAYOUTS: TYPICAL REGULATORY SIGNS

Visitors Check-in at Guardhouse Ahead

area covered by frame

2 1/2”

3 3/4”

7 1/4”

CL

TYPICAL GRAPHIC LAYOUT Sign Types VDR.1R, VDR.2R, REG.1 TYPEFACE: T1 MAX. LINE LENGTH SHALL NOT BE WITHIN 2” OF BORDER

2”

Authorized Vehicles Beyond this Point

EQ.

5 1/2”

EQ.

CL

TYPICAL GRAPHIC LAYOUT Sign Types REG.2 TYPEFACE: T1 MAX. LINE LENGTH SHALL NOT BE WITHIN 1” OF EDGE

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

40


EQ.

area covered

HOU SE

TYPICAL GRAPHIC LAYOUT Sign Types BLD.2 GRAPHIC PANEL LAYOUTS: TYPEFACE: T2 MAX. LINE101 LENGTH SHALL NOT BE WITHIN 2” OF BORDER SPECIAL LOCATION LAYOUT

Smithsonian Conservation Biology Institute

area covered by frame - typical

2 1/2”

Welcome to

1’-3”

3 3/4”

1’-1/2”

CL

UNIQUE GRAPHIC LAYOUT Sign Location 101 TYPEFACE: T1 MAX. LINE LENGTH SHALL NOT BE WITHIN 2” OF BORDER

DE PA RTM E NT OF AN I MAL PRO GR AM NAT IONAL EC OLO GICAL OB SE RVATORY N ET WORK

area covered by frame - all sides

3” 1”

N EON

EQ.

1 3/4” 2” 7 1/2”

EQ.

CL

UNIQUE GRAPHIC LAYOUT Sign Location 312 TYPEFACE: T2 MAX. LINE LENGTH SHALL NOT BE WITHIN 2” OF BORDER

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

41


smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

42


programming documents Programming is defined as the combination of sign locations and messages paired succinctly to aid navigation. This section includes sign location plans and message schedules. These documents direct the location and information for each sign in the program.

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

43


SIGN LOCATION PLAN NUMBERING CONVENTIONS Symbol Sign Types Description

1xx 1xx VDR.1, VDR.2, VDR.3, VDR.1R, VDR.2R Vehicular Directional Signs 1xx 2xx 2xx 2xx PRK.1 Parking Lot Identification Sign 3xx 3xx BLD.1, BLD.2 Building Identification Sign 3xx 4xx 4xx

4xx REG.1, REG.2 Regulatory Sign 5xx STR.1, STR.2 Street Identification Sign 5xx 5xx

Administration Auditorium Academic Center Dining Hall Residence & Meeting Center

Administration Auditorium Parking Lot C

Academic Center Dining Hall NEON Residence & Meeting Center

Parking Lots D-E Dining Hall NEON

VDR.2

VDR.1

Accessible Parking & Deliveries for Administration

VDR.3

Accessible Parking & Deliveries for Administration

Authorized Vehicles Beyond this Point

Authorized Vehicles Beyond this Point

VDR.2R

VDR.1R

Authorized Vehicles Beyond this Point

P

SLATE HILL DR

PARKI NG

Lot A R AC ET R AC K H IL L

PRK.1

BLD.1

THE WEMMER HOUSE

BLD.2

Authorized Vehicles Beyond this Point

REG.1

STR.1

REG.2

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

44


St re e

x 4x x

EY

5x

LL DA B IR RE

SE

AR

CH

DR

IV

E

SIGN LOCATION PLAN

311 SLA

TE H

A

ILL D

109

r

M

Accessible Parking

508

Other Buildings

503

RIV

E

AUD

117

ITOR

IUM

Sh e

Parking

Visitor Parking

E et Tit Si xter le Fi gn ior na L l S oc Da te ub atio 04 m n .0 itt Pl 9. 20 al an 1

201

OAD

ER EAD

S t OF CBI Nam e EO W Pr ay oj fin ec d t N in o. g S : 0 ig 87 nag 01 e 07

308

Key Destinations

je c

310

be

120

8. 00

E

IN.

Pr o

ADM

Location not shown on plan (Racetrack Hill ID Sign)

Main Path of Travel

um

RIV

tN

ND

je c

TIO

33

504 110

TRA

Pr o

INIS

21

ADM

111

LON GHI LL R OAD

112

AD

CONSERVATION DRIV E

309

405

E RO

E RIV

VIC

HD RC SEA RE

SER

10 Su 40 Ba ite Hu T: ltim 10 ll S tre F: 41 or 0 et 41 0.3 e, 0. 47 MD Do 34 .8 2 cu 7. 50 12 m 85 0 3 en 0 tT 19 itl e

Map Key

108

Bus Drop-Off & Deliveries

307

VA ER NS

Parking

B

202

Parking

G CE

NTE

E DRIV

118

R DR

IVE

312

TC

303

LE

302

IRC

TRA

304 115

510

509

306

119 203

404

507

506

C

RE

MR

OAD

401

TIO

ND

RIV

E

FAR

206

CO

505

ININ

GA

TE

HO

106

102

ARCH

105

502

114

FER

104

107 403

WE

205

MM

ER R

OAD

116

Parking

E

305

VE

RIVE

US

E

ION D

RI ER D

113

RVAT

NEO

CONSE

RESE

406

DIN HALING L

103

& M RESID EET ENC ING E CEN TER

501

N

CON

SER

ACA CENDEMIC TER

VAT

ION

DRI

VE

301

402

Reference Gate 2 and 3 Improvement Project documents for proposed signage at Gates 2 and 3

G

WE

Parking

ININ TRA

ER

RO

314

313

MM

204

AD

T CEN

101

D

Reference Gate 2 and 3 Improvement Project documents for proposed signage at Gates 2 and 3

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

45


smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

46


SIGN MESSAGE SCHEDULE Location Sign Type Message

Status

101

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

VDR.2R

(side a -­‐ upper panel) Welcome to the Smithsonian Conservation Biology Institute

Notes

(side a -­‐ lower panel) Visitor Check-­‐in at Gatehouse ahead (side b -­‐ upper panel) (straight-­‐right arrow) Front Royal (straight-­‐left arrow) Flint Hill (side b -­‐ lower panel) (blank)

102

VDR.2

(side a) (up-­‐left arrow) Check-­‐in at Gatehouse

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

Locate sign in the field adjacent to future gatehouse. Sign shall direct to gatehouse parking area.

(side b) (blank)

103

VDR.2

(side a) > All Visitor Traffic

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(side b) (blank)

104

VDR.1

(side a) (straight-­‐left arrow) Parking Lot A Administration Auditorium

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

^ Academic Center Dining Hall NEON Residence & Meeting Center (side b) (blank)

105

VDR.1

(side a) < Administration Auditorium

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

^ Academic Center Dining Hall NEON Residence & Meeting Center (side b) (blank)

106

VDR.1

(side a) > Parking Lots B-­‐E Dining Hall smithsonian NEON conservation biology Residence & Meeting Center

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

institute | signage & wayfinding master plan | 10.07.2015

47


< Administration Auditorium

[ ] DELETE [ ] HOLD [ ] REVISE

^ Academic Center Dining Hall NEON Residence & Meeting Center (side b) SIGN MESSAGE SCHEDULE (blank) Location Sign Type Message

Status

106

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

VDR.1

(side a) > Parking Lots B-­‐E Dining Hall NEON Residence & Meeting Center

Notes

(side b) (blank)

107

VDR.2

(side a) > Parking Lot C

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

< Parking Lots D-­‐E Dining Hall NEON (side b) (blank)

108

VDR.1

(side a) < Parking Lot A Administration

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

^ Accessible Parking & Deliveries for Administration (side b) (blank)

109

VDR.2

(side a) > Parking Lots B-­‐E Exit

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(side b) (blank)

110

VDR.2R

(side a -­‐ upper panel) < Accessible Parking & Deliveries for Administration

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(side a -­‐ lower panel) Authorized Vehicles Beyond this Point (side b -­‐ upper panel) ^ Exit (side b -­‐ lower panel) (blank)

111

VDR.2

(side a) < Accessible Parking & Deliveries for Administration (side b)

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

smithsonian (blank) conservation biology institute | signage & wayfinding master plan | 10.07.2015

48


Administration (side a -­‐ lower panel) Authorized Vehicles Beyond this Point (side b -­‐ upper panel) ^ Exit (side b -­‐ lower panel) SIGN MESSAGE SCHEDULE (blank)

Location Sign Type Message

Status

111

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

VDR.2

(side a) < Accessible Parking & Deliveries for Administration

Notes

(side b) (blank)

112

VDR.2

(side a) < Exit

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(side b) (blank)

113

VDR.1

(side a) > Administration Auditorium

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

^ Exit (side b) (blank)

114

VDR.2

(side a) > Exit

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

< Parking Lots B-­‐E Dining Hall NEON Residence & Meeting Center (side b) (blank)

115

VDR.2

(side a) (u-­‐turn symbol) Exit via Wemmer Rd

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(side b) (blank)

116

VDR.2

(side a) < All Visitor Traffic

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(side b) (blank)

117

VDR.2

(side a) ^ Exit

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(side b) (blank)

118

VDR.2

(side a) > Exit via smithsonian Wemmer conservation Rd

biology institute

[ ] APPROVED [ ] DELETE [ ] HOLD signage [ |] REVISE

& wayfinding master plan | 10.07.2015

49


All Visitor Traffic

[ ] HOLD [ ] REVISE

(side b) (blank)

117

VDR.2

(side a) ^ Exit

(side b) SIGN MESSAGE SCHEDULE

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(blank)

Location Sign Type Message

Status

118

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

VDR.2

(side a) > Exit via Wemmer Rd

Notes

(side b) (blank)

119

N/A

> Exit via Farm Rd

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

Panel mounts to building

120

N/A

^ (accessible symbol) Accessible Ramp

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

Panel mounts to building

201

PRK.1

(side a) (parking symbol) PARKING

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

Lot A (side b) (parking symbol) PARKING Lot A

202

PRK.1

(side a) (parking symbol) PARKING Lot B

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(side b) (parking symbol) PARKING Lot B

203

PRK.1

(side a) (parking symbol) PARKING Lot C

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(side b) (blank)

204

PRK.1

(side a) (parking symbol) PARKING Lot D

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(side b) ^ Exit via Farm Rd

205

PRK.1

(side a) (parking symbol) PARKING Lot E

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(side b) ^ Exit via Farm Rd

smithsonian conservation biology institute [ |] Asignage & wayfinding master plan | 10.07.2015 206 PRK.1 (side a) PPROVED (parking symbol) PARKING

[ ] DELETE

50


(blank)

204

PRK.1

(side a) (parking symbol) PARKING Lot D

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(side b) ^ Exit via Farm Rd

SIGN MESSAGE SCHEDULE Location Sign Type Message

Status

205

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

PRK.1

(side a) (parking symbol) PARKING Lot E

Notes

(side b) ^ Exit via Farm Rd

206

PRK.1

(side a) (parking symbol) PARKING SCBI Employees

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(side b) (parking symbol) PARKING SCBI Employees

301

BLD.1

(side a) ACADEMIC CENTER

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

Existing sign to remain

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

Existing sign to remain

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

Existing sign to remain

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

Existing sign to remain

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

Existing sign to remain

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

Existing sign to remain

(side b) ACADEMIC CENTER

302

BLD.1

(side a) RESIDENCE & MEETING CENTER (side b) RESIDENCE & MEETING CENTER

303

BLD.1

(side a) DINING HALL (side b) DINING HALL

304

BLD.1

(side a) DINING HALL (side b) DINING HALL

305

BLD.1

(side a) RESIDENCE & MEETING CENTER (side b) RESIDENCE & MEETING CENTER

306

BLD.1

(side a) RESIDENCE & MEETING CENTER

b) smithsonian (side conservation biology institute | signage & wayfinding master plan | 10.07.2015 RESIDENCE & MEETING CENTER

51


305

BLD.1

(side a) RESIDENCE & MEETING CENTER

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

Existing sign to remain

Location Sign Type Message

Status

Notes

306

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

Existing sign to remain

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

Sign shall be placed at an angle, locate in field with owner

(side b)

RESIDENCE SIGN MESSAGE SCHEDULE & MEETING CENTER

BLD.1

(side a) RESIDENCE & MEETING CENTER (side b) RESIDENCE & MEETING CENTER

307

BLD.1

(side a) AUDITORIUM (side b) AUDITORIUM

308

BLD.1

(side a) ADMINISTRATION (side b) ADMINISTRATION

309

BLD.1

(side a) RACETRACK HILL

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

Locate in field with owner

(side b) RACETRACK HILL

310

BLD.1

(side a) POLICE (side b) POLICE

311

BLD.1

(side a) ANIMAL PROGRAMS (side b) ANIMAL PROGRAMS

312

BLD.1

(side a) NEON (side b) NEON

313

BLD.2

(side a) THE WEMMER HOUSE (side b) THE WEMMER HOUSE

314

BLD.2

(side a) THE WEMMER HOUSE (side b) THE WEMMER HOUSE

401

REG.1

(side a) Authorized Vehicles Beyond this Point (side b)

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

smithsonian (blank) conservation biology institute | signage & wayfinding master plan | 10.07.2015

52


313

BLD.2

(side a) THE WEMMER HOUSE (side b) THE WEMMER HOUSE

314

BLD.2

(side a) THE WEMMER HOUSE

(side b) SCHEDULE SIGN MESSAGE

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

THE WEMMER HOUSE

Location Sign Type Message

Status

401

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

REG.1

(side a) Authorized Vehicles Beyond this Point

Notes

(side b) (blank)

402

REG.1

(side a) Authorized Vehicles Beyond this Point

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(side b) (blank)

403

REG.1

(side a) Authorized Vehicles Beyond this Point

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(side b) (blank)

404

REG.1

(side a) Authorized Vehicles Beyond this Point

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(side b) (blank)

405

REG.1

(side a) Authorized Vehicles Beyond this Point

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(side b) (blank)

406

REG.1

(side a) Authorized Vehicles Beyond this Point

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(side b) (blank)

501

STR.1

(upper panel -­‐ side a) CONSERVATION DR (upper panel -­‐ side b) CONSERVATION DR

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(lower panel -­‐ side a) (street name) (lower panel -­‐ side b) (street name)

502

STR.2

(upper panel -­‐ side a) CONSERVATION DR (upper panel -­‐ side b) CONSERVATION DR

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(lower panel -­‐ side a) TRAINING CENTER RD (lower panel -­‐ side b) TRAINING CENTER RD

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

53


501

STR.1

(upper panel -­‐ side a) CONSERVATION DR (upper panel -­‐ side b) CONSERVATION DR

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(lower panel -­‐ side a) (street name) (lower pSCHEDULE anel -­‐ side b) SIGN MESSAGE (street name)

Location Sign Type Message

Status

502

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

STR.2

(upper panel -­‐ side a) CONSERVATION DR (upper panel -­‐ side b) CONSERVATION DR

Notes

(lower panel -­‐ side a) TRAINING CENTER RD (lower panel -­‐ side b) TRAINING CENTER RD

503

STR.1

(upper panel -­‐ side a) SLATE HILL DR (upper panel -­‐ side b) SLATE HILL DR

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(lower panel -­‐ side a) CONSERVATION DR (lower panel -­‐ side b) CONSERVATION DR

504

STR.1

(upper panel -­‐ side a) ADMINISTRATION DR (upper panel -­‐ side b) ADMINISTRATION DR

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(lower panel -­‐ side a) CONSERVATION DR (lower panel -­‐ side b) CONSERVATION DR

505

STR.1

(upper panel -­‐ side a) FARM RD (upper panel -­‐ side b) FARM RD

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(lower panel -­‐ side a) TRAINING CENTER RD (lower panel -­‐ side b) TRAINING CENTER RD

506

STR.2

(upper panel -­‐ side a) FARM RD (upper panel -­‐ side b) FARM RD

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(lower panel -­‐ side a) WEMMER RD (lower panel -­‐ side b) WEMMER RD

507

STR.1

(upper panel -­‐ side a) WEMMER RD (upper panel -­‐ side b) WEMMER RD (lower panel -­‐ side a)

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

smithsonian TRAINING conservation CENTER RD biology institute | signage & wayfinding master plan | 10.07.2015

54


506

STR.2

(upper panel -­‐ side a) FARM RD (upper panel -­‐ side b) FARM RD

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(lower panel -­‐ side a) WEMMER RD (lower pSCHEDULE anel -­‐ side b) SIGN MESSAGE WEMMER RD

Location Sign Type Message

Status

507

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

STR.1

(upper panel -­‐ side a) WEMMER RD (upper panel -­‐ side b) WEMMER RD

Notes

(lower panel -­‐ side a) TRAINING CENTER RD (lower panel -­‐ side b) TRAINING CENTER RD

508

STR.1

(upper panel -­‐ side a) LONGHILL RD (upper panel -­‐ side b) LONGHILL RD

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(lower panel -­‐ side a) RESEARCH DR (lower panel -­‐ side b) RESEARCH DR

509

STR.1

(upper panel -­‐ side a) FERRET CIR (upper panel -­‐ side b) FERRET CIR

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(lower panel -­‐ side a) RESEARCH DR (lower panel -­‐ side b) RESEARCH DR

510

STR.1

(upper panel -­‐ side a) WEMMER RD (upper panel -­‐ side b) WEMMER RD

[ ] APPROVED [ ] DELETE [ ] HOLD [ ] REVISE

(lower panel -­‐ side a) TRAINING CENTER RD (lower panel -­‐ side b) TRAINING CENTER RD

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

55


smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

56


smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

57


Ayers Saint Gross 1040 Hull Street, Suite 100 Baltimore, MD 21230 www.asg-architects.com

smithsonian conservation biology institute | signage & wayfinding master plan | 10.07.2015

58


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.