DRAFTING EXAMPLE - Doncaster East Unit 2

Page 1

NOTE: PLUMBER TO DETERMINE SEWER STACK LOCATION

elec. & hot/cold conduit for d/w

elec. conduit for ppt.to bench 135mm stepdown to garage


O/A

PROVIDE R2.0 WALL INSULATION BATTS. PROVIDE R5.0 CEILING INSULATION BATTS. PROVIDE R5.0 CEILING INSULATION BATTS TO GARAGE CEILING. GARAGE

MASTER BED.

ENS.

FAMILY/MEALS

A HANDRAIL MUST BE LOCATED AT LEAST ONE SIDE OF THE STAIR FLIGHT AND BE NO LESS THAN 865mm VERTICALLY ABOVE THE NOSING OF THE STAIR TREADS. HANDRAIL MUST BE CONTINUOUS AND HAVE NO OBSTRUCTIONS ON HANDHOLD, EXCEPT FOR NEWEL POSTS, BALL TYPE STANCHIONS OR THE LIKE; IN ACCORDANCE WITH PART 3.9.2.4 OF THE BUILDING CODE OF AUSTRALIA 2012.

ENS./W.I.R.

STAIR

HALL

X

STAIR

STAIR

ENTRY/MEALS B A06

STORE 6M3

dp

dp SHR.

ENS.

line of F.F. above

STORE

C A07

dp

PORCH PLASTER CEILING

step

L'DRY

PANTRY

LEGEND

dp

PORCH

LIN.

135mm stepdown to garage

P'DR

PIER

bulkhead @ 2340H

KITCHEN

KITCHEN

L'DRY

dp

gas meter concrete floor

broom

P'DR 1 line of F.F. above

beam to engineer's design + specification

GARAGE

dp

PORCH

sectional colorbond o/head door w/ remote

waterfall end

beam to engineer's design + specification

L'DRY

A A05

PIER

ENTRY

HALL

MEALS ENTRYLHALL

STAIR

STAIR

bulkhead @ 2340H

W.I.R.

GARAGE

PLASTER CEILING

D A08

sectional colorbond o/head door w/ remote

retaining wall to engineers' design

DIRECT WIRED SMOKE DETECTOR ARTICULATION JOINT CAPPED COLD WATER POINT (@300H TO REF. SPACE) CAPPED HOT WATER POINT OPENING IN WALL FOR PLUMBING RISER STACK INSPECTION OPENING CEILING EXHAUST FAN 25 L/SEC SWITCHED WITH LIGHT

STORE 6M3

2000L water tank dp

dp

O/A

FAMILY

O/A

MASTER BED.

PLASTER CEILING

FAMILY/MEALS/KITCHEN

plaster lined wall

FAMILY/MEALS

ENS.

ENS.

GARAGE

line of F.F. above

W.I.R.

MASTER BED.

GARAGE

SHR.

dp

HOT WATER SYSTEM TAP FLOOR WASTE CAPPED WASTE POINT CAPPED GAS POINT

ENTRY

KITCHEN

L'DRY

LIN.

MANHOLE 700x500 METER BOX WITH GAS METER UNDERNEATH

GARAGE

X

P'DR GARAGE

METER BOX GAS METER


O/A

PROVIDE R2.0 WALL INSULATION BATTS. PROVIDE R5.0 CEILING INSULATION BATTS. PROVIDE R5.0 CEILING INSULATION BATTS TO GARAGE CEILING. BED 2

STAIR

STAIR

ROBE

BED 3

P'DR

Y

A HANDRAIL MUST BE LOCATED AT LEAST ONE SIDE OF THE STAIR FLIGHT AND BE NO LESS THAN 865mm VERTICALLY ABOVE THE NOSING OF THE STAIR TREADS. HANDRAIL MUST BE CONTINUOUS AND HAVE NO OBSTRUCTIONS ON HANDHOLD, EXCEPT FOR NEWEL POSTS, BALL TYPE STANCHIONS OR THE LIKE; IN ACCORDANCE WITH PART 3.9.2.4 OF THE BUILDING CODE OF AUSTRALIA 2012.

ROBE

X

B A06

dp dp

dp/s

BED 3

O/A

ROBE

V. HALL

P'DR 2

ROBE

BATH

BATH

BED 4

BED 4

V.

dp

V.

V.

P'DR

HALL

C A07

ROBE

HALL P'DR

A A05 linen

STAIR STAIR

ROBE

STAIR

O/A

sliding doors 2300H

BED 3

BED 2

LINEN

BED 2

Y

ROBE

ROBE

sliding doors 2300H

LEGEND

dp

sliding doors 2300H dp/s

DIRECT WIRED SMOKE DETECTOR ARTICULATION JOINT

dp

CAPPED COLD WATER POINT (@300H TO REF. SPACE) CAPPED HOT WATER POINT D A08

OPENING IN WALL FOR PLUMBING RISER STACK INSPECTION OPENING CEILING EXHAUST FAN 25 L/SEC SWITCHED WITH LIGHT HOT WATER SYSTEM TAP FLOOR WASTE CAPPED WASTE POINT V.

P'DR

CAPPED GAS POINT

V.

MANHOLE 700x500 BATH

ROBE

BED 4

METER BOX WITH GAS METER UNDERNEATH METER BOX

O/A

X

GAS METER


rendered 75mm foamboard cladding

title boundary

title boundary

NOTE:SENSOR LIGHTS ABOVE FRONT ENTRY AND ABOVE GARAGE DOOR

roof tiles

eave off frame

25° ROOF PITCH

88.265 88.093

87.860

88.130

sectional garage door rendered brickwork MAX H. 1000MM SLEEPER RETAINING WALL

A

selected brickwork

MAX H. 1400MM SLEEPER RETAINING WALL


title boundary

rendered 75mm foamboard cladding

25° ROOF PITCH eave off frame

roof tiles

88.265 87.860 2000 L R/W TANK

WATER PUMP CONDENSER

MAX H. 1850MM SLEEPER RETAINING WALL

B

aluminium framed window

selected brickwork

MAX H. 1000MM SLEEPER RETAINING WALL


rendered 75mm foamboard cladding

eave off frame

roof tiles 25° ROOF PITCH

title boundary

title boundary

OBS max 25% transparency & fixed up to 1.7m from FFL (openable above 1.7m)

HWS

88.130

88.265

CONDENSER 2000 L R/W TANK

MAX H.2250MM SLEEPER RETAINING WALL

C

WATER PUMP

selected brickwork

aluminium framed window

MAX H.1850MM SLEEPER RETAINING WALL


NOTE:SENSOR LIGHTS ABOVE ABOVE GARAGE DOOR

roof tiles 25° ROOF PITCH

eave off frame

88.265

87.860

UNIT 1 GARAGE

D

rendered 75mm foamboard cladding

sectional garage door

title boundary

NOTE:SENSOR LIGHTS ABOVE FRONT ENTRY AND ABOVE GARAGE DOOR

88.130

timber front entry door

gas meter rendered brickwork

selected brickwork

2000 L R/W TANK MAX H. 2250MM SLEEPER RETAINING WALL


NOTE: ALL WINDOWS VIEWED FROM OUTSIDE

NOTE: OVERALL DEPTH OFF FRAME OF ALL WINDOWS IS 165MM I.E. WOODEN REVEAL + ALUMINIUM FRAME

OBSCURE

NOTE: ALL GLASS TO CONFORM WITH AS1288-2006: GLASS IN BUILDINGS

OBSCURE

EX 40 OUT

A

D

OBSCURE

OBSCURE

OBSCURE

OBSCURE

EX 40 IN

C

B


O/A

NOTES ON CABINET DETAILING

O/A

INFILL

CARCASS/ REF. SPACE

CARCASS

CARCASS

CARCASS

CARCASS

CARCASS

ALL END PANELS (EXCEPT AT SIDES OF UPRIGHT OVEN) TO BE CONCEALED BEHIND DOORS/DRAWERS AND IN LINE WITH CARCASS (I.E. DOORS CLOSE OVER)

INFILL

INFILL PANELS AT SIDES OF DOORS TO BE IN LINE WITH FRONT OF DOORS AND DRAWERS

glass s/back

waste bin

B'TOP & SUBSTRATE

waterfall end

s/s undermount sink

D/W

CARCASS

CARCASS

W/O

selected 40mm stone benchtop

INFILL AT TOP OF KITCHEN OVERHEAD DOORS (IF REQUIRED) TO BE IN LINE WITH CARCASS (I.E. SET BACK FROM DOOR FACE)

O/A B'TOP

SPLASHBACK

undermount rangehood

selected stone b'top

selected tap

CARCASS

M/O

REF.

REF. SPACE

CARCASS W/O SPACE M/O SPACE

CARCASS

CARCASS

TO SINK PANTRY

CARCASS

CARCASS

D/W SPACE CARCASS

B

INFILL

A

CARCASS

O/A BENCHTOP

CARCASS

CARCASS

CARCASS

CARCASS

CARCASS

M/O W/O

PANTRY

INFILL

CARCASS

bottom of carcass stepped up 5mm from door, carcass back and end panels CARCASS

DOOR

INFILL

REF. SPACE

CARCASS

REF. SPACE

REF. SPACE

INFILL

DRWS

DRWS

INFILL

DRWS

A

C

B

DRWS

D/W

CUP'D

DRWS

refer to base cupboard details O/A BENCHTOP

O/A BENCHTOP

CUP'D

O'HANG

DOOR, END PANEL & CARCASS BACK

CARCASS

B'TOP & SUBSTRATE CARCASS

O/A B'TOP

SPLASHBACK CARCASS

O/A BENCHTOP

CARCASS D/W SPACE

CARCASS

CARCASS

O/A BENCHTOP

C

O/A B'TOP

O'HANG

BULKHEAD

CARCASS


NOTES ON CABINET DETAILING

O/A B'TOP

BROOM CARCASS

bottom of carcass stepped up 5mm from door, carcass back and end panels

DOOR

CUP'D

O'HANG FROM CARCASS

B'TOP

CARCASS

DOOR

substrate fixed to carcass from underside only - NO fixing through top

door

RAIL

laminate kicker

O/A

stone benchtop

STONE O'HANG FROM CARCASS

O/A B'TOP

W/M SPACE

DRAWER O'HANG

B'TOP O/A DRAWERS

O/A B'TOP

TROUGH & SPOUT

CARCASS

B'TOP & SUBSTRATE

CARCASS

refer to overhead cupboard details

substrate fixed to carcass from underside only - NO fixing through top O'HANG FROM DOOR FRONT

CARCASS CARCASS

INFILL

O/A B'TOP

laminate kicker

A

SHADOW B'TOP LINE

O/A DOOR

CARCASS

O/A B'TOP

B'TOP & SUBSTRATE

laminate top

B'TOP

DOOR, END PANELS & CARCASS BACK

A

W/M SPACE

INFILL AT TOP OF KITCHEN OVERHEAD DOORS (IF REQUIRED) TO BE IN LINE WITH CARCASS (I.E. SET BACK FROM DOOR FACE)

O'HANG

CUP'D

W/M

INFILL PANELS AT SIDES OF DOORS TO BE IN LINE WITH FRONT OF DOORS AND DRAWERS

CARCASS

SHADOW LINE

O/A B'TOP

CARCASS

SUBSTRATE

W/M SPACE

ALL END PANELS (EXCEPT AT SIDES OF UPRIGHT OVEN) TO BE CONCEALED BEHIND DOORS/DRAWERS AND IN LINE WITH CARCASS (I.E. DOORS CLOSE OVER)


extent of tiling

extent of tiling

CARCASS

INFILL CARCASS

INFILL

CARCASS

O/A BENCHTOP

CARCASS

O/A BENCHTOP CARCASS

CARCASS

20mm shadowline

INFILL

O/A BENCHTOP

O/A BENCHTOP

BASIN & SPOUT

stone vanity top & return edge

CARCASS

INFILL

CARCASS CARCASS CARCASS

O/A BENCHTOP

KICKER SETBACK

KICKER SETBACK

KICKER

AS PER ELEV. TO MIRROR EDGE

O/A DOOR

CARCASS

O'HANG FROM DOOR FRONT

KICKER

laminate kicker

counter top basin O/A BENCHTOP

KICKER

adjustable shelf

O/A DOOR

CARCASS

TO BASIN

AS PER ELEV.

substrate fixed to carcass from underside only - NO fixing through top

backing board to arrised mirror edge. 16mm edged melamine board by cabinet makers

B'TOP

SHADOW LINE

O/A B'TOP

BENCHTOP

BENCH

O/A BENCHTOP

MIRROR PLAN VIEW

adjustable shelf laminate kicker KICKER

NOTES ON WET AREA CABINET DETAILING CARCASS DOOR

CARCASS DOOR

ALL END PANELS TO BE CONCEALED BEHIND DOORS/DRAWERS AND IN LINE WITH CARCASS (I.E. DOORS CLOSE OVER) INFILL PANELS AT SIDES OF DOORS TO BE IN LINE WITH DOORS AND DRAWERS INFILL AT TOP OF OVERHEAD DOORS (IF REQUIRED) TO BE IN LINE WITH CARCASS (I.E. SET BACK FROM DOOR FACE)

CARCASS

BASIN & SPOUT

BASIN & SPOUT

CARCASS INFILL

O/A BENCHTOP

O/A BENCHTOP

BASIN & SPOUT

1409w x 1100h polished edge mirror on backing board

875 x 1100h polished edge mirror on backing board

1085w x 1100h polished edge mirror on backing board

O/A BENCHTOP

1545w x 1100h polished edge mirror on backing board


LIGHTING LEGEND

GENERAL NOTES ALL LED DOWNLIGHTS TO BE SUPPLIED BY ELECTRICIAN

ELECTRICAL LEGEND 10A 10A 10A DOUBLE POWER POINT @1350mm

CEILING BATTEN LIGHT FITTING (15w) EXT. WALL MOUNTED LIGHT FITTING @1800 HIGH (15w)

10A 10A SINGLE POWER POINT @1350mm

HANGING PENDANT LIGHT FITTING (15w)

10A 10A SINGLE POWER POINT @300mm

1200

SINGLE FLUORESCENT LIGHT (1200) (36w)

10A WP DOUBLE EXTERNAL POWER POINT

ALL SINGLE & DOUBLE POWERPOINTS FOR ISLAND BENCH @750MM

1200

DOUBLE FLUORESCENT LIGHT (1200) (36w)

ALL POWERPOINTS ABOVE WALL BENCHTOP @1100MM

600

DOUBLE FLUORESCENT LIGHT (600) (36w)

LIGHTING FOR KITCHEN CABINETRY REFER TO KITCHEN INTERNAL DRAWINGS FOR LIGHTING LOCATIONS

NOTES ON ALL KITCHEN POWER OUTLETS

10A DOUBLE POWER POINT @1350mm 10A DOUBLE POWER POINT @300mm

400

STORE 6M3

RANGEHOOD POWERPOINT @1800MM

10A DOUBLE EXTERNAL POWER POINT @1100mm

FLUORESCENT LIGHT 10A WP SINGLE EXTERNAL POWER POINT

REFRIGERATOR POWERPOINT @1500MM

SINGLE PARA FLOOD LIGHT (100w) DOUBLE PARA FLOOD LIGHT (200w) 1200

INT. WALL LIGHT BATTEN HOLDER @2100 (15w)

ENS.

2-way switch to unit 1

GARAGE

MASTER BED.

11.5

11.5

LIGHT OUTLET & SINGLE POWER POINT TO ROOF

11.5

quad plate

ceiling mounted for garage remote

FAMILY 11.5

1200

11.5

C9

LED CABINET DOWNLIGHT (9w)

11.5

LED DOWNLIGHT (12w)

9

W.I.R.

STEP LIGHTING @300mm ABOVE TREAD (90x90) (20w) 11.5

S 11.5

MEALS

@750h for d/w

11.5

11.5

11.5

11.5

11.5

DIMMER SWITCH @1350mm

11.5

11.5

@1500h for w/m

11.5

@750h 11.5

400

C9

C9

L'DRY

@750h for h/p

1200

@1200h for w/o on sep. circuit

ceiling mounted for garage remote

@1500h for ref.

P'DR 1

@1500h for r/h

15A EXT POWER POINT FOR SINGLE PHASE CONDENSER 3 PHASE POWER POINT FOR A/C UNIT CEILING EXHAUST FAN 25 L/SEC SWITCHED WITH LIGHT DIRECT WIRED SMOKE DETECTOR CEILING EXHAUST FAN WITHOUT DRAFT STOPPERS

4 LIGHT/FAN/HEATER COMBO

CEILING EXHAUST FAN WITH DRAFT STOPPERS

2 LIGHT/FAN/HEATER COMBO

FUSE BOX

11.5

GAS METER DATA / FIBRE OPTIC POINT TELEPHONE POINT MOVEMENT SENSOR

broom

PANTRY

SINGLE POWER POINT @1200mm ON SEPARATE CIRCUIT FOR WALL OVEN

JUNCTION BOX @2000mm APPROX.

@1500h for m/o

11.5

10A POWER POINT FOR SECURITY SYSTEM

METER BOX @1900 TO TOP

11.5

KITCHEN PORCH

LED DOWNLIGHT (9w)

10A SINGLE POWER POINT @300mm S

PROVISION FOR SEPARATE POWERPOINTS FOR WALL OVEN TOWER

TELEVISION ANTENNA POINT

HVAC LEGEND ADD-ON REFRIGERATIVE AIR CONDITIONING UNIT

GARAGE

CEILING HEATING OUTLET 400

HEATING THERMOSTAT HEATING UNIT (LOCATED IN CEILING)

STORE

RETURN AIR EVAPORATIVE COOLING OUTLET EVAPORATIVE COOLING UNIT LOCATION HOT WATER SYSTEM LOCATION

LIGHTING CALCULATOR Internal House Area (NOT incl. garage, alfresco etc.) Maximum Wattage Permitted (MAX 5w p/m2)

180 m2 900W Total Watts

- Where external lights are provided, all external lights to have a daylight sensor - Owners to ensure that all future external lighting is to have an average of 40 lumens/W

ROOF ACCESS Watts 0

RINNAI INFINITY CONTROL POINT 0


LIGHTING LEGEND

GENERAL NOTES ALL 12 VOLT DOWNLIGHTS TO BE SUPPLIED BY ELECTRICIAN

ELECTRICAL LEGEND 10A 10A 10A DOUBLE POWER POINT @1350mm

CEILING BATTEN LIGHT FITTING (15w) EXT. WALL MOUNTED LIGHT FITTING @1800 HIGH (15w)

10A 10A SINGLE POWER POINT @1350mm

HANGING PENDANT LIGHT FITTING (15w)

10A 10A SINGLE POWER POINT @300mm

1200

SINGLE FLUORESCENT LIGHT (1200) (36w)

10A WP DOUBLE EXTERNAL POWER POINT

ALL SINGLE & DOUBLE POWERPOINTS FOR ISLAND BENCH @750MM

1200

DOUBLE FLUORESCENT LIGHT (1200) (36w)

ALL POWERPOINTS ABOVE WALL BENCHTOP @1100MM

600

DOUBLE FLUORESCENT LIGHT (600) (36w)

LIGHTING FOR KITCHEN CABINETRY REFER TO KITCHEN INTERNAL DRAWINGS FOR LIGHTING LOCATIONS

NOTES ON ALL KITCHEN POWER OUTLETS

10A DOUBLE EXTERNAL POWER POINT @1100mm 10A DOUBLE POWER POINT @1350mm 10A DOUBLE POWER POINT @300mm

400

RANGEHOOD POWERPOINT @1800MM

FLUORESCENT LIGHT 10A WP SINGLE EXTERNAL POWER POINT

REFRIGERATOR POWERPOINT @1500MM

SINGLE PARA FLOOD LIGHT (100w) DOUBLE PARA FLOOD LIGHT (200w) INT. WALL LIGHT BATTEN HOLDER @2100 (15w) LIGHT OUTLET & SINGLE POWER POINT TO ROOF

BED 3

ROBE

BED 2

C9

LED CABINET DOWNLIGHT (9w)

11.5

LED DOWNLIGHT (12w)

9

STEP LIGHTING @300mm ABOVE TREAD (90x90) (20w)

ROBE

11.5 11.5

P'DR 2

linen

DIMMER SWITCH @1350mm 11.5

11.5

LED DOWNLIGHT (9w)

10A SINGLE POWER POINT @300mm S

PROVISION FOR SEPARATE POWERPOINTS FOR WALL OVEN TOWER

10A POWER POINT FOR SECURITY SYSTEM SINGLE POWER POINT @1200mm ON SEPARATE CIRCUIT FOR WALL OVEN 15A EXT POWER POINT FOR SINGLE PHASE CONDENSER 3 PHASE POWER POINT FOR A/C UNIT CEILING EXHAUST FAN 25 L/SEC SWITCHED WITH LIGHT DIRECT WIRED SMOKE DETECTOR CEILING EXHAUST FAN WITHOUT DRAFT STOPPERS

4 LIGHT/FAN/HEATER COMBO

CEILING EXHAUST FAN WITH DRAFT STOPPERS

2 LIGHT/FAN/HEATER COMBO

FUSE BOX

11.5

JUNCTION BOX @2000mm APPROX. METER BOX @1900 TO TOP GAS METER

BED 4 11.5

ROBE

BATH

DATA / FIBRE OPTIC POINT TELEPHONE POINT MOVEMENT SENSOR TELEVISION ANTENNA POINT

HVAC LEGEND ADD-ON REFRIGERATIVE AIR CONDITIONING UNIT CEILING HEATING OUTLET HEATING THERMOSTAT HEATING UNIT (LOCATED IN CEILING) RETURN AIR EVAPORATIVE COOLING OUTLET EVAPORATIVE COOLING UNIT LOCATION HOT WATER SYSTEM LOCATION

LIGHTING CALCULATOR Internal House Area (NOT incl. garage, alfresco etc.) Maximum Wattage Permitted (MAX 5w p/m2)

180 m2 900W Total Watts

- Where external lights are provided, all external lights to have a daylight sensor - Owners to ensure that all future external lighting is to have an average of 40 lumens/W

ROOF ACCESS Watts 0

RINNAI INFINITY CONTROL POINT 0


NOTE: REFER TO ENGINEER'S FOOTING DESIGN

FLASHING

BOX GUTTER timber roof trusses to manufacturer's specifications

roof tiles at 25 deg. pitch

roof tiles at 25 deg. pitch

HALL

BED 2

BATH TIMBER CLEAT

KITCHEN ENS.

W.I.R.

GARAGE

STORE

50MM THICK ACOUSTIC INSULATION EXTENDING 600MM BOTH SIDES (REQUIRED FOR FLANKING SOUND CONTROL)

PLASTER

GARAGE 50MM THICK ACOUSTIC INSULATION

A

B

50MM THICK ACOUSTIC INSULATION EXTENDING 600MM BOTH SIDES (REQUIRED FOR FLANKING SOUND CONTROL)


TRUSSES PROVIDE FULL HT. ARTICULATION JOINT (FOOTING TO EAVE) AT 6m MAX CENTRES. (UNLESS STATED IN SOIL REPORT) (SEE DETAIL BELOW)

CLOSED CELL POLYETHYLENE JOINT FILLER

METAL GUTTER

METAL FASCIA

A

PLASTER

ROOF TRUSS AS PER MANUFACTURERS SPEC. TERRACOTTA TILED ROOF

B G.S. SPOUTING

BACKING PLATE FOR FIXING OF GUTTER & FLASHING.

C

FASCIA

SELECTED PLASTER CORNICE

METAL FLASHING FIXED TO PITCHING BEAM PRIOR TO INSTALLAION OF FASCIA