Bulletin 16MED2
Since 1895
Lighting Innovators
LED Medical Lighting Patient & Facility
Featuring: OPTeCOLOR™ (95+ CRI) LED, BioGard™, IP65 Trims,1 ISO 5 Class 100
INFRALED® • INFRALED® 60 • OPTe MED™ 3401 East Jefferson Avenue, Detroit MI 48207-4232 313-259-6400 • FAX: 313-259-3121 • www.kirlinlighting.com • info@kirlinlighting.com
Search by design and application Section
Application / Design
Page
Kirlin Expertise and Dependability Since 1895
4-5
Section I
SmartLED™ MRI Introduction and Section Table of Contents
6-9
SmartLED™ MRI Lighting Systems
Downlight and Sconce Lighting Systems: 1. Luminaires 2. Driver 3. Filter
Downlight, Adjustable and Wall Wash Luminaires
10-13
Sconces (ADA Compliant) and Luminaire Options
14
Remote Driver (Required)
15
RFI/EMI Filter (Required) Emergency Power Supply (Optional)
16-19
Room Configurations, Wiring Diagrams
20
Downlighting Design Guide and Checklist Scenic Panel (2 x 2 Configurable) Systems: 1. Luminaires 2. Driver 3. Filter
21-23
Scenic Panel Remote Driver (Required)
24
RFI/EMI Filter (Required)
25-27
Room Configuration, Checklist, Wiring Diagrams
Section II
Patient Exam Introduction and Section Table of Contents Lensed BioGard™ Antimicrobial Trim
Level 1 Infection Control
IP65 Rated Sealed Trim; Tamper Resistant
Level 2 and Level 2 + Infection Control
Motorized Patient Exam (With Remote & Wall Controls)
Section IV
IP65 ISO 5
Class 100 Sealed Fixture; Tamper Resistant Level 3 and Level 3 + Infection Control
Section III
™
rd
Ga
Bio
™
rd
Ga
Bio
IP65
CLASS
Patient Exam
28-29 30
™
rd
Ga
Bio
100
CLEANROOM
VR VR
31 32
Patient Exam Performance, Typical Installations, Options and Ordering Guide
33-35
Motorized Patient Exam Introduction and Section Table of Contents
36-37
OB and LDRP
INFRALED 60: Fully Recessed with Remote Control & Wall Control
38-39
ICU, CCU, PICU, NICU, ED, Cath Lab, OR Patient Room, Pathology
INFRALED®: Fully Recessed with Remote Control & Wall Control
40-41
™
OPTeMED : Fully Recessed with Wall Control
42-43
ShowerLights Introduction and Section Table of Contents
44-45
®
Gasketed Flare Trim - Non-Conductive
ShowerLights: Dead Front
46
IP65 Rated and Tamper Resistant Trim - Non-Conductive Super Shallow Housing and Gasketed Trim - Non-Conductive
(Non-Conductive)
Gasketed Drop Polycarbonate Trim - Non-Conductive
47
ShowerLight Options and Ordering Guide
Section V
48-49
General Lighting and Clinical Spaces Introduction and Section Table of Contents
50-51
Round and Square
IP65 Rated Sealed Trim; Tamper Resistant
Level 2 and Level 2 + Infection Control
Class 100 Sealed Fixture (Cleanroom)
Level 3 Infection Control, Sealed Fixture, BioGard™
™
IP65
rd
Ga
Bio
VR
51-52
ISO 5
™
rd
Ga
Bio
IP65
CLASS
General Lighting: Public and Clinical Spaces
Downlight, Wall Wash and Super Shallow
52
100
CLEANROOM
53
General Lighting and Clinical Space Options and Ordering Guide
Section VI
Scenic Panel (2 x 2 Configurable) Systems (for Non-MRI Use)
54-57
NightLights / ChartLights and StepLights Introduction and Section Table of Contents
58-59
NightLights / ChartLights
NightLights / ChartLights NightLights and StepLights
60
Inconspicuous (Round, Square, Rectangle) and Brick Light Single and Double Face
61
Maximum Security
(Type IC)
StepLight
62
Inconspicuous (Round, Square, Rectangle) and Brick Light
63
NightLight / ChartLight and StepLight Options and Ordering Guide
LUMINAIRE numbering LOGIC MRR-07500-5000L-120-30K-MFL
Options
Series
Voltage
M = Medical
Must Specify
Mount R = Recessed S = Surface N = NightLight
Page 2
Shape/Design R = Round S = Square T = Rectangle V = Vandal P = Panel (Scenic)
Lumen Series Must Specify
Size
Sequence in Catalog
Recessed Aperture Surface Diameter
www.kirlinlighting.com
Search by Number Product #
Description
Pg
first 3 characters alphabetically sorted: last 5 characters numerically Product #
Description
Pg
Product #
Backup Power MRI
15
MRR-05825-2500L
Patient Room
51
MRR-08835-3500L
Backup Power Exam
35
MRR-06205-1500L
MRI
10
MRR-08835-2500L
LPS-0700A
Remote Driver MRI
24
MRR-06230-1500L
Remote Driver MRI
15
MRR-06235-1500L
MRI
11
LPS-1220A
Remote Driver Exam
35
MRR-06420-2500L
Remote Driver General
53
MRR-06422-2500L
MNR-05900
NightLight/ChartLight
60
MRR-06424-2500L
MNR-05920
StepLight
62
MRR-06426-2500L
MNS-05904
NightLight/ChartLight
60
MRR-06427-2500L
MNS-05924
StepLight
62
MRR-06705-1500L
NightLight/ChartLight
60
EMI-21220
MNT-03906 MNT-03908 MNT-03926 MNT-03928
StepLight
62
MNT-07912 MNT-07914
NightLight
61
MNV-07916
MRR-06705-1000L MRR-06705-500L
MRP-22295
Scenic Panel
54
MRR-06810-2500L
MRI
10
MRR-06815-3500L
12
MRR-06815-2500L
MRR-04700-2500L
MRR-07240-1500L
46
MRR-04720-500L
40
MRR-12642
Motorized Exam OPTeMED™
42
MRS-04245-1500L
MRI
11
Patient Room
50
MRS-08470-2500L
MRI
13
MRS-17600
Birthing INFRALED® 60
38
Patient Exam
30
Patient Exam
32
Shower
46
Patient Room
52
Patient Exam
31
Patient Exam
32
Patient Room
52
MRI Cylinder
13
MRI Sconce
14
RFI/EMI MRI Filter
15 24
MRR-12620 MRR-12622
MRI
Shower
13
46
Patient Room
50
MRR-06815-5000L
MRR-04225-1500L
MRR-04720-1000L
MRI
MRR-12640
MRS-04803-1500L MRS-04803-1000L
MRS-04804-1000L
MRR-06810-3500L
Shower
Motorized Exam INFRALED®
MRR-08855-2500L
MRR-06805-3500L
21
MRR-04720-1500L
52
MRR-08855-3500L
MRS-04804-1500L
MRI Scenic Panel
MRR-04200-1500L
Patient Room
MRR-08855-5000L
MRR-06805-5000L
MRP-22290
MRR-04220-1500L
51
MRS-04803-500L
MRR-06810-5000L
MRR-07505-5000L
MRS-04804-500L
MRT-04510-5000L Patient Room
51
MRT-05515-7000L MRT-05515-5000L
MRI
11
MRR-07500-5000L MRR-07500-3500L
MRV-07560-1500L MRV-07715-1500L
Patient Exam
30
MRV-07715-1000L MRV-07715-500L
MRR-04800-1500L
MRR-07505-3500L
MRR-04800-1000L
MRR-07550-1500L
Patient Exam
32
MRV-08540-5000L
MRR-04800-500L
MRR-07830-1500L
Patient Room
51
MRV-08540-3500L
MRR-07850-1500L
Patient Room
52
MRV-08545-5000L
MRR-04802-1000L
MRR-08428-2500L
MRI
13
MRV-08545-3500L
MRR-04802-500L
MRR-08530-5000L
MRV-08565-5000L
MRR-04820-1500L
MRR-08530-3500L
MRV-08565-3500L
MRR-04802-1500L
MRR-04820-1000L
Patient Room
50
Patient Room
51
Shower
46
MRR-04820-500L MRR-05725-2500L MRR-05730-1500L MRR-05730-1000L MRR-05730-500L
MRR-08535-5000L
Shower
MRR-05735-2500L
47
MRV-07840-1500L
Patient Exam
31
MRV-08845-5000L
MRR-08535-3500L
MRV-08845-3500L
MRR-08555-5000L
MRV-08845-2500L
MRR-08555-3500L MRR-08558-5000L
Patient Exam
32
MRR-08558-3500L MRR-08835-5000L
Pg
Patient Room
MRR-06710-2500L
MRR-06805-2500L
Description
MSR-12440-2500L MSR-14250 MSS-10255
Patient Room
51
RFI-3100D
MAGNIFYING GLASS ICON (FOUND THROUGHOUT CATALOG) INDICATES TABLE OF CONTENTS PLEASE VISIT www.kirlinlighting.com FOR: KIRLIN MEDICAL LIGHTING PRODUCTS WITH OTHER LIGHT SOURCES IN KIRLIN’S PATIENT EXAM & HEALTHCARE LIGHTING CATALOG (BULLETIN 08HC) AND KIRLIN’S COMPLETE COLLECTION OF LED LUMINAIRES IN KIRLIN’S LATITUDES LED LIGHTING CATALOG (BULLETIN 15/16LED).
www.kirlinlighting.com
Page 3
Kirlin Expertise and Dependability since 1895 A SAFER ENVIRONMENT FOR PATIENTS AND STAFF oG
Bi
d™ ar
IP65 ISO 5 CLASS
• Fully recessed fixtures provide an open work space. • IP65 rated sealed trims and ISO 5 Class 100 rated sealed fixtures provide optimal protection against pathogen transmission through luminaires. • BioGard™ antimicrobial trim finish inhibits survival of pathogens. • Compact and smooth trims, lenses and controls are easy to clean and disinfect. • Dead-front (non-conductive) shower trims protect patients and staff. • Attractive, inconspicuous vandal resistant designs ideal for ED, psychiatric units and public spaces.
100
CLEANROOM
BioGard™ antimicrobial finish inhibits the growth of infectious microbes on luminaire trims. IP65 rated sealed and gasketed trims prevent dust and sprayed liquids from entering the fixture through the trim/lens assembly. ISO 5 Class 100 Cleanroom rated sealed fixtures prevent particles larger than 5 microns from passing through the fixture.
HIGHER QUALITY LIGHT For more accurate diagnosis and improved visual acuity
KIRLIN OPTeCOLOR™ LED
Common CRI
• High color rendering LEDs assure accurate tissue color rendering: 95+ CRI with excellent R9 (Red), R13 and R15 (Skin Colors) • Ideal color temperatures for specific tasks: 3500K (Neutral white: Standard), 3000K (Warm white: Option -30K), 4100K (Cool white: Option -41K) or 5000K (Daylight white: Option -50K). • Up to 9000 footcandles are provided for the most demanding and intricate medical procedures. • -SPT, -NFL, -MFL and -WFL distributions available.
High CRI
GREATER CONTROL FOR IMPROVED CARE • Kirlin delivers dimmable light from multiple sources, at proper angles, with optimal light levels to reduce shadows and illuminate clinicians’ line of site. • Intuitive and responsive controls for our motorized lighting systems provide quick and accurate adjustment of direction and intensity of the light. • Dimming down to 10% (and 0.2% for MRI lighting systems) permits staff to finely tune light levels for specific tasks, each clinician and time of day. • SmartSupply™ MRI lighting system remote driver controls up to twelve fixtures with 3 zones of dimming.
Page 4
www.kirlinlighting.com
Kirlin Expertise and Dependability since 1895
GREATER COMFORT FOR PATIENT AND STAFF • LED does not project heat toward the room environment, assuring patient and practitioner comfort while avoiding tissue desiccation. • SmartLED™ Scenic Panels create a soothing, attractive, and more natural environment to reduce patient stress, promoting the healing process. • Inconspicuous: Fully recessed fixtures provide a more residential atmosphere; motorized lighting systems’ controls do not invade patient’s personal space. • INFRALED® Series’ remote controls use invisible infrared signals to prevent unintended consequences, such as migraines and photosensitive epileptic seizures. • Red/Amber (Option -RA) NightLights maintain patients’ melatonin levels and proper circadian rhythm, ensuring restful nights and time for healing.
REDUCED OPERATING COSTS
ARRA
QUALIFIED
IC
• Long LED life, up to 90,000 hours (L70), results in 90 fewer lamp changes over the life of the system. • Corrosion resistant all-aluminum construction extends every components’ life by 50% due to operating 25% cooler. • Power consumption is typically only 20% of traditional light sources. • Fully sustainable. Modular, internal components are visible and easily accessed through the aperture of the fixture. Lighthead may be inexpensively updated to change spacing criteria, light level and color temperature. • Luminaires are designed for multiple lumen packages, allowing the specifier to select the most energy efficient solution for each application. • LEDs produce up to 80% less heat than traditional light sources, significantly reducing the load on hospital HVAC systems. • Shallow and super shallow recessed housings fit easily in crowded plenums. • Type IC standard on most models including all MRI luminaires, all -1500L/ -1000L/-500L luminares and all NightLights, StepLights and ChartLights.
Designed and Produced in U.S.A. • UL, C-UL (Canada) Listed www.kirlinlighting.com
Page 5
SECTION I: SmartLED™ MRI - THE turnkey KIRLIN SYSTEM SmartLED™ NON FERROMAGNETIC luminaires • Award winning 1500 lumen and 2500 lumen ambient downlights, adjustable task lighting and wall washes. Wall sconces and surface mount available. • Up to 4 spacing criteria available: From 0.3 (SPT) for task lighting to 1.1 (WFL) for ambient lighting. 2011 Architectural SSL Product Innovation Award
SmartLED™ Scenic Panels • Beautiful photography or custom art with soothing back lighting in 2x2 recessed panels with flared reveal. • Creates a calming environment to reduce patient stress and assist in the healing process. • Limitless configurations available to maximize impact and match the unique dimensions of each suite.
SmartSupply™ remote driver 2011 IES Progress Report Selections
• Controls up to twelve fixtures (1500L Series) or twelve Scenic Panels or six fixtures (2500L Series). • Dims to 0.2% permitting finely tuned light levels. • 3 zones of dimming for luminaires. • Conveniently mounted outside the shield
SmartFilter™ RFI/EMI filter • PROVEN to work with MRI equipment (up to 7 Tesla) from all of the major manufacturers. • Industry leading RFI/EMI protection. • Superior insertion loss of 100dB (minimum) • Easily installed on exterior surface of shield Page 6
www.kirlinlighting.com
SECTION I: SmartLED™ MRI LUMINAIRE SYSTEM Design
Function
Aperture (Inches)
Product #
Performance Lumens
Watts
1500 LUMEN MRI Downlight, Adjustable and Wall Wash luminaires
Page 10-11
Open Appearance
Downlight
4
MRR-04200-1500L
1500
20
Open Appearance
Downlight
6
MRR-06205-1500L
1500
20 10
Open Appearance
Adjustable
4
MRR-04220-1500L
1500
20
Open Appearance
Wall Wash
4
MRR-04225-1500L
1500
20
Flare with Regressed Lens
Downlight
6
MRR-06230-1500L
1500
20
Flare with Regressed Lens
Downlight
6
MRR-06235-1500L
1500
20 11
IP65 Infection Control
Downlight
7
MRR-07240-1500L
1500
20
Square Flare with Regressed Lens
Downlight
4
MRS-04245-1500L
1500
20
MRI Sconces - ADA COMPLIANT - only 2½” protrusion from wall Round Center Field Edge Glow
Sconce
14
14
MSR-14250
20 14
Square Center Field Edge Glow
Sconce
10
MSS-10255
20
SmartLED™ MRI Table of Contents - continued on pages 8-9
PLEASE VISIT www.kirlinlighting.com FOR KIRLIN INCANDESCENT MRI LIGHTING PRODUCTS IN KIRLIN’S PATIENT EXAM & HEALTHCARE LIGHTING CATALOG (BULLETIN 08HC).
www.kirlinlighting.com
Page 7
SECTION I: SmartLED™ MRI LUMINAIRE SYSTEM Design
Function
Aperture (Inches)
Product #
Performance Lumens
Watts
2500 Lumen MRI Downlight, Adjustable and Wall Wash LUMINAIRES
Page 12-13
Open Appearance Lensed
Downlight
6
MRR-06420-2500L
2500
35
Open Appearance Lensed
Adjustable
6
MRR-06422-2500L
2500
35
Open Appearance Lensed
Wall Wash
6
MRR-06424-2500L
2500
35
Flare with Regressed Lens
Downlight
6
MRR-06426-2500L
2500
35
Flare with Regressed Lens
Downlight
6
MRR-06427-2500L
2500
35
IP65 Infection Control
Downlight
8
MRR-08428-2500L
2500
35
Surface Mount Flat Trim
Downlight
12
MSR-12440-2500L
2500
35
K-Lens Recessed Square
Downlight
8
MRS-08470-2500L
2500
35
LUMINAIRE and sconce SYSTEM COMPONENTS
12
13
14
Required For Luminaires
SmartSupply™ (1400mA)
Remote Driver
LPS-1220A
Required For Luminaires
SmartFilter™
RFI/EMI Filter
RFI-3100D
Optional For Luminaires
SmartPower™ (Optional)
Emergency Power Supply
EMI-21220
15
DOWNLIGHTING typical SYSTEM configuration and Photometric Performance
16
Typical System Configurations FOR DOWNLIGHTING
17
Typical Wiring Overview and Wiring Diagram for luminaires
18-19
DOWNLIGHTING luminaire system Design Guide and Checklist
20
PLEASE VISIT www.kirlinlighting.com FOR KIRLIN INCANDESCENT MRI LIGHTING PRODUCTS IN KIRLIN’S PATIENT EXAM & HEALTHCARE LIGHTING CATALOG (BULLETIN 08HC).
Page 8
www.kirlinlighting.com
SECTION I: SmartLED™ MRI SCENIC PANEL SYSTEM Design
Function
Aperture (Inches)
Product #
24
MRP-22290
Scenic Panel: 2’x2’ Building Block Configuration
Performance Watts
20
Page
21
SCENIC PANEL IMAGES
22
SCENIC PANEL CONFIGURATIONS & product specification guide
23
Required For SmartSupply™ (700mA) Scenic Panels
Remote Driver
LPS-0700A 24
Required For SmartFilter™ Scenic Panels
RFI/EMI Filter
RFI-3100D
TYPICAL SYSTEM CONFIGURATION FOR SCENIC PANELS & SCENIC PANEL CHECKLIST Typical Wiring Overview and Wiring Diagram for SCENIC PANELS
25 26-27
SECTION I: SmartLED™ MRI SCENIC PANEL SYSTEM
SmartLED™ Scenic Panels • Beautiful photography or custom art with soothing back lighting in 2x2 recessed panels with flared reveal. • Creates a soothing environment to reduce patient stress and assist in the healing process. • Configurable overall size to suit the unique dimensions of each MRI suite.
www.kirlinlighting.com
Page 9
MRI LUMINAIRE SYSTEM: 1500 Lumen Series (-1500L)
IC
4” PERFORMANCE (-1500L Series) 1538 LUMENS 20W MFL (std) SC: 0.8
Downlights
LPW: 74
90˚ 75˚
800
60˚
1600 2400 0˚
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
64.9 36.5 23.4 16.2 11.9 9.1
4.9 6.6 8.2 9.9 11.5 13.2
-SPT
-NFL
Lm: 1629 SC: 0.3
Lm: 1428 SC: 0.6
-SPT
-NFL
Lm: 1706 SC: 0.3
Lm: 1588 SC: 0.6
-SPT
-MFL
Lm: 1566 SC: 0.4
Lm: 1557 SC: 0.8
MRR-04200-1500L
6” PERFORMANCE (-1500L Series) 1670 Lumens 20W MFL (std) SC: 0.8 LPW: 80
90˚ 75˚
850
60˚
1700 2550 0˚
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
67.2 37.8 24.2 16.8 12.3 9.4
5.0 6.7 8.3 10.0 11.6 13.3
MRR-06205-1500L
4” PERFORMANCE (-1500L Series)
Adjustable
1564 Lumens 20W
2000
NFL (std)
4000
SC: 0.5 LPW: 75
MRR-04220-1500L
90˚
6000 0˚
75˚ 60˚ 45˚ 15˚
30˚
2011 Architectural SSL Product Innovation Award
4” PERFORMANCE (-1500L Series)
Wall Wash
90˚
1375 Lumens 20W LPW: 66
75˚
550
60˚
1100 1650 0˚
45˚ 15˚
30˚
▲ Cone of Light Key
Ft. Distance from fixture FC Footcandles at nadir (0°) Dia. Circle of light at 50% of FC Dia. (in ft.) shown is where FC value is half the FC at nadir.
MRR-04225-1500L
Use of both Kirlin SmartSupply™ LPS-1220A (1400mA) and SmartFilter™ RFI-3100D are required to maintain Kirlin warranty. Page 10
www.kirlinlighting.com
MRI LUMINAIRE SYSTEM: 1500 Lumen Series (-1500L) 6”
PERFORMANCE (-1500L Series) 1721 Lumens 20W MFL (std) SC: 0.8
Lensed Downlights
IC
LPW: 83
90˚ 75˚
800
60˚
1600 2400 0˚
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
67.3 37.8 24.2 16.8 12.4 9.5
4.9 6.6 8.2 9.9 11.5 13.2
-SPT
-NFL
-WFL
Lm: 1744 SC: 0.3
Lm: 1553 SC: 0.6
Lm: 1514 SC: 1.1
-SPT
-NFL
-WFL
Lm: 1744 SC: 0.3
Lm: 1553 SC: 0.6
Lm: 1514 SC: 1.1
-SPT
-NFL
-WFL
Lm: 1744 SC: 0.3
Lm: 1553 SC: 0.6
Lm: 1514 SC: 1.1
MRR-06230-1500L
6”
PERFORMANCE (-1500L Series) 1721 Lumens 20W MFL (std) SC: 0.8 LPW: 83
MRR-06235-1500L
90˚ 75˚
800
60˚
1600 2400 0˚
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
67.3 37.8 24.2 16.8 12.4 9.5
4.9 6.6 8.2 9.9 11.5 13.2
2011 Architectural SSL Product Innovation Award
7”
IP65 Downlight
PERFORMANCE (-1500L Series) 1721 Lumens 20W MFL (std) SC: 0.8 LPW: 83
MRR-07240-1500L
IP65
90˚ 75˚
800
60˚
1600 2400 0˚
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
67.3 37.8 24.2 16.8 12.4 9.5
4.9 6.6 8.2 9.9 11.5 13.2
™ rd
Ga
Bio
4”
Lensed Downlight
PERFORMANCE (-1500L Series) 1606 Lumens 20W MFL (std) SC: 0.8 LPW: 76
90˚ 75˚
800
60˚
1600 2400 0˚
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
67.8 38.1 24.4 16.9 12.4 9.5
4.7 6.3 7.8 9.4 11.0 12.5
-NFL
Lm: 1589 SC: 0.5
MRS-04245-1500L
Use of both Kirlin SmartSupply™ LPS-1220A (1400mA) and SmartFilter™ RFI-3100D are required to maintain Kirlin warranty. www.kirlinlighting.com
Page 11
MRI LUMINAIRE SYSTEM: 2500 Lumen Series (-2500L)
IC
6” PERFORMANCE (-2500L Series)
Downlight
3058 Lumens 35W MFL (std) SC: 0.8 LPW: 87
90˚ 75˚
1500
60˚
3000 4500 0˚
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
114.3 64.3 41.2 28.6 21.0 16.1
5.1 6.8 8.5 10.2 11.9 13.6
-SPT
-NFL
Lm: 3168 SC: 0.3
Lm: 2922 SC: 0.6
-SPT
-MFL
Lm: 3008 SC: 0.3
Lm: 2997 SC: 0.8
MRR-06420-2500L
6” PERFORMANCE (-2500L Series)
Adjustable
2732 Lumens
90˚
35W
2000
NFL (std)
4000
SC: 0.6 LPW: 78
6000 0˚
75˚ 60˚ 45˚ 15˚
30˚
MRR-06422-2500L
6” PERFORMANCE (-2500L Series)
Wall Wash
90˚
2772 Lumens
1000
35W
2000
LPW: 79
3000 0˚
75˚ 60˚ 45˚ 15˚
▲ Cone of Light Key
Ft. Distance from fixture FC Footcandles at nadir (0°) Dia. Circle of light at 50% of FC Dia. (in ft.) shown is where FC value is half the FC at nadir.
30˚
MRR-06424-2500L
Use of both Kirlin SmartSupply™ LPS-1220A (1400mA) and SmartFilter™ RFI-3100D are required to maintain Kirlin warranty. Page 12
www.kirlinlighting.com
MRI LUMINAIRE SYSTEM: 2500 Lumen Series (-2500L) PERFORMANCE (-2500L Series)
6” 2993 Lumens 35W
Lensed Downlights
MFL (std) SC: 0.8 LPW: 81
MRR-06426-2500L
75˚
1250
60˚
2500 3750 0˚
45˚ 15˚
2993 Lumens
MFL (std) SC: 0.8 LPW: 81
MRR-06427-2500L
90˚ 75˚
1250
60˚
2500 3750 0˚
45˚ 15˚
3030 Lumens 35W MFL (std) SC: 0.8
Surface Downlight
MRR-08428-2500L
Lensed Downlight
Dist.
FC
Dia.
6 8 10 12 14 16
109.0 61.6 39.4 27.4 20.1 15.4
5.0 6.7 8.4 10.0 11.7 13.4
-NFL
-WFL
Lm: 2888 SC: 0.5
Lm: 2379 SC: 1.0
30˚
Cone of Light ▲
-NFL
-WFL
Dist.
FC
Dia.
6 8 10 12 14 16
109.0 61.6 39.4 27.4 20.1 15.4
5.0 6.7 8.4 10.0 11.7 13.4
Lm: 2888 SC: 0.5
Lm: 2379 SC: 1.0
PERFORMANCE (-2500L Series)
8”
8”
30˚
Cone of Light ▲
PERFORMANCE (-2500L Series)
35W
IP65 Downlight
90˚
6”
12”
IC
IP65
G
Bio
d™ ar
LPW: 82
90˚ 75˚
1250
60˚
2500 3750 0˚
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
110.0 61.7 39.5 27.4 20.2 15.4
4.9 6.6 8.2 9.9 11.5 13.1
-NFL
Lm: 3010 SC: 0.5
PERFORMANCE (-2500L Series) 3147 Lumens 35W
90˚ 75˚
1150
60˚
2300
SC: 0.8
MSR-12440-2500L
LPW: 89
3450 0˚
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
103.0 58.1 37.2 25.8 19.0 14.5
4.9 6.6 8.2 9.7 11.5 13.2
PERFORMANCE (-2500L Series) 2693 Lumens 35W WFL (std) SC: 1.2
MRS-08470-2500L
LPW: 76
Cone of Light ▲ 0
90˚ 75˚
330
60˚
660 990 0˚
45˚ 15˚
30˚
Dist.
FC
Dia.
6 8 10 12 14 16
28.4 16.0 10.2 7.1 5.2 4.0
7.1 9.5 11.9 14.3 16.6 19.0
▲ Cone of Light Key
Ft. Distance from fixture FC Footcandles at nadir (0°) Dia. Circle of light at 50% of FC Dia. (in ft.) shown is where FC value is half the FC at nadir.
Use of both Kirlin SmartSupply™ LPS-1220A (1400mA) and SmartFilter™ RFI-3100D are required to maintain Kirlin warranty. www.kirlinlighting.com
Page 13
MRI sconce SYSTEM: ADA COMPLIANT - 2½” from the wall LED Light Engine
Brushed Anodized Aluminum Housing
• 1300 lumen, 20 watt LED array • 3500°K CCT standard • 90,000 hours (L70) • Fully sustainable: Removable for servicing
• 2 ½” depth meets all ADA requirements • All aluminum construction maximizes cool operation and component life • Optional housing and faceplate finishes
Sconce Assembly
• Decorative brushed aluminum faceplate and housing with clear 1/4” acrylic diffuser • Illuminated center field and edge glow.
Installation
• Wall or ceiling mount • Universal back plate mounts to any non-ferromagnetic octagon or 4” square J-box (provided by others).
MSR-14250
MSS-10255
Red Wing Red Option -RE
Circadian Red / Amber Option -RA
Tiger Orange Option -OR
Wolverine Maize Option -YE
Spartan Green Option -GN
Lion Blue Option -BL
Custom Image / Logo Option -CI
Use of both Kirlin SmartSupply™ LPS-1220A (1400mA) and SmartFilter™ RFI-3100D are required to maintain Kirlin warranty.
POPULAR LUMINAIRE and Sconce Options DOWNLIGHTS Input Power: SPECIFY -120 120V (50-60Hz) input. -277 277V (50-60Hz) input. -97 Specify other voltage. Consult factory.
Color Temperature (CCT) -27K -30K -41K -HC
Color temperature 2700°K instead. Color temperature 3000°K instead. Color temperature 4100°K instead. 90+ CRI instead. Use with Option -27K or -30K only. Reduces output by ~15%.
Optics -NFL Narrow flood distribution. -SPT Spot distribution. -WFL Wide flood distribution.
Lenses & Trims -13 -17 -21
Vandal resistant dual lens system: prismatic high strength acrylic above, clear poly below, instead of standard lens. .187” prismatic high strength acrylic lens instead. Also see Option -26. White translucent flat poly diffuser instead.
Page 14
SCONCES -23 -26
Frosted microprismatic lens instead. Tamper-resistant button head recessed hex screw with center pin and 1 key / 10 fixtures. -30 All white acrylic enameled cone. -31 White acrylic enameled flange (only) on cone. -32 White oversize trim ring. Specify O.D. -45 Gasket between trim flange and ceiling. -46 Gasket between trim and lens. -70 SofTex Clear self-flanged cone. (CP x .95) -94 Custom color/finish. Specify. Consult factory. -BG Antimicrobial Kirlin BioGard™ white (only) trim finish. -WA White acrylic (flat) diffuser instead.
Surface Housing Finishes -35 -38 -94
(White Standard)
Natural aluminum (silver) acrylic enamel. Black acrylic enamel. Custom color. Specify. Consult factory.
Other -79 -99
Faceplate & Housing -30 -38 -94 -BG
White baked enamel finish instead. Black baked enamel finish instead. Custom color/finish. Specify. Consult factory. Antimicrobial Kirlin BioGard™ white (only) finish.
Colors: Center Field & Edge Glow -BL -CF -GN -OR -RA -RE -YE
Blue (filter). Custom (filter) color (Rosco). Specify. Green (filter). Orange (filter). Red amber (filter). Red (filter). Yellow (filter).
Other -CI
Custom image (color/logo) in center field of sconce.
Extension collar for up to 2” thick ceilings. Special modification. Consult factory.
(See specification sheets for availability and details.) www.kirlinlighting.com
MRI SmartSupply™ REMOTE DIMMING DRIVER - REQUIRED • Full range 100% to 0.2% dimming and 3 dimming zones. See page 18 or consult factory for compatible controls. • Over wattage, cross channel, and electrical fast transient (EFT) protection. • Mounted outside MRI shield (not directly to shield). • Input: 115-277VAC / 50-60Hz rated. Dedicated 120VAC input recommended. For 277VAC input, proper line filtering and surge protection must be provided (by others). Maximum continuous input voltage is 290VAC. • Requires 16 AWG (minimum) twisted pair shielded wire from SmartSupply™ to luminaires. • FIVE YEAR Limited Warranty.
LPS-1220A
2011 IES Progress Report Selection
With 1500 Lumen Series (-1500L) SmartLED™ Luminaires
(6) Channels (Circuits) Maximum Distance Per Channel
With 2500 Lumen Series (-2500L) SmartLED™ Luminaires
Up to (2) luminaires / channel
(1) luminaire / channel
Up to (12) luminaires / SmartSupply™
Up to (6) luminaires / SmartSupply™
(1) luminaire / channel: 150 feet
(1) luminaire / channel: 150 feet
(2) luminaires / channel: 50 feet *
*Distance to the farthest fixture
SmartFilter™ DC RFI / EMI FILTER - REQUIRED
2011 IES Progress Report Selection
RFI-3100D
• Industry leading RFI and EMI protection • Superior insertion loss of 100 dB (min.) • Fully protects 20 kHz to 1.0 GHz • One filter protects up to three SmartSupply™ channels • Up to two filters required per SmartSupply™ • Mounted on outside surface of MRI shield • FIVE YEAR Limited Warranty
SmartPower™ EMERGENCY BACKUP SYSTEM - OPTIONAL • High efficiency pure sine wave inverter • Operates up to two fully loaded SmartSupply™ drivers • 100% light output for up to 2 hours • 120 / 277V, 60Hz input • May be mounted up to 1000 feet from load
• Less than 0.05 seconds transfer time • UL 924 Listed. Meets or exceeds all NEC and Life Safety Code Emergency Lighting Requirements • THREE YEAR Limited Warranty. SEVEN YEAR pro-rata battery warranty
EMI-21220
MRI SYSTEM ORDERING EXAMPLE Quantity
Product
Description
12
MRR-06205-1500L-120V-41K-WFL
Luminaires
1
LPS-1220A
SmartSupply™ (1400mA) driver (required)
2
RFI-3100D
SmartFilter™ DC RFI/EMI filter (required)
www.kirlinlighting.com
Page 15
MRI LUMINAIRE SYSTEM: TYPICAL CONFIGURATION
Photo courtesy of Haselden Construction 6' - 10"
22' - 8"
MRI Room
14' - 6"
Equipment Room (1) EMI-21220
6' - 6"
Zone 3 45 fc Zone 2 85 fc
(4) RFI-3100D
(2) LPS-1220A
MRI
Control Room
Zone 1 100 fc
MRI Shield
19' - 9"
Typical MRI Suite Lighting Zones and Component Locations
0-10VDC Dimmer
PRODUCTS Product Type
Product #
Qty
Location
Adjustable Task Lighting
MRR-06424
4
Over the transfer table
Fixed Ambient Downlights
MRR-06426
8
Perimeter of MRI room
Remote Drivers
LPS-1220A
2
Outside the MRI shield
EMI/RFI Filters
RFI-3100D
4
On the MRI shield
Emergency Inverter
EMI-21220
1
Outside the MRI shield
0-10VDC Dimmers
See page 26
2
In the control room
Page 16
PHOTOMETRIC performance Zone
Location
fc
1
Transfer Table
100
2
Near Transfer Table
85
3
MRI Perimeter
45
Luminaires Product #
Qty
MRR-06424
4
MRR-06426
8
www.kirlinlighting.com
MRI LUMINAIRE SYSTEM: Typical Configurations 1500 Lumen (20W) Luminaires RFI / EMI Shield Kirlin SmartLED™ Luminaire
• Up to (12) 20W luminaires per SmartSupply • Up to (2) luminaires per SmartSupply channel (circuit). • Each color represents (1) set of (3) channels Kirlin SmartFilter™ RFI-3100D (Required) • (1) filter protects up to (3) SmartSupply channels. Each color represents (1) set of (3) channels • Up to (2) filters required per SmartSupply • Mounted on outside surface of MRI shield Kirlin SmartSupply™ LPS-1220A (Required) • (6) channels -- Up to (2) luminaires per channel -- Up to (12) luminaires per SmartSupply • Max distance per channel -- 150’ with (1) luminaire per channel -- 50’ with (2) luminaires per channel • Mounted outside MRI shield (not directly to shield) Kirlin SmartPower™ EMI-21220 (Optional) • Max distance from load: 1000’ • Mounted outside MRI shield (not directly to shield)
2500 Lumen (35W) Luminaires RFI / EMI Shield Kirlin SmartLED™ Luminaire
• Up to (6) 35W luminaires per SmartSupply • (1) luminaire per SmartSupply channel (circuit). • Each color represents (1) set of (3) channels Kirlin SmartFilter™ RFI-3100D (Required) • (1) filter protects up to (3) SmartSupply channels. Each color represents (1) set of (3) channels • Up to (2) filters required per SmartSupply • Mounted on outside surface of MRI shield Kirlin SmartSupply™ LPS-1220A (Required) • (6) channels -- Up to (1) luminaire per channel -- Up to (6) luminaires per SmartSupply • Max distance per channel: -- 100’ with (1) luminaire per channel • Mounted outside MRI shield (not directly to shield) Kirlin SmartPower™ EMI-21220 (Optional) • Max distance from load: 1000’ • Mounted outside MRI shield (not directly to shield)
www.kirlinlighting.com
Page 17
MRI LUMINAIRE SYSTEM: Typical Wiring Overview This wiring overview provides dimming control for zones 1, 2 and 3 simultaneously with a 0-10V DC dimmer* connected to the master 0-10V DC input of the SmartSupply™.
Shown with: • • • • •
Use of both Kirlin SmartSupply (1400mA) and SmartFilter are required to maintain Kirlin warranty.
(1) SmartSupply™ LPS-1220A (2) SmartFilters™ RFI-3100D (6) 1500 Lumen Series (20W) Luminaires (3) 2500 Lumen Series (35W) Luminaires (1) Wall Box Dimmer*
Requires 16 AWG (minimum) twisted pair shielded wire from SmartSupply (1400mA) to luminaires.
CHANNELS 5, 6
JUNCTION BOX
SmartSupply™ LPS-1220A (Output)
SmartFilter™
SmartFilter™
RFI-3100D
RFI-3100D
GREY
CHANNEL 6
CHANNEL 5
CHANNEL 4
CHANNEL 3
SmartSupply™ LPS-1220A (Input)
CHANNEL 2
CHANNEL 1
PURPLE
CHANNELS 5, 6
CHANNELS 3, 4
CHANNELS 3, 4
CHANNELS 1, 2
CHANNELS 1, 2
2500L (35W) Luminaires
WALL BOX DIMMER*
LINE
1500L (20W) Luminaires
AC INPUT
NEUTRAL
Wall dimmer must be mounted OUTSIDE of room shield. Dimming control wires MUST NOT connect through the filter.
* Kirlin recommends using the following compatible 0-10V DC dimmers: Leviton
Lightolier
Acuity
IP710-DLX ZP600FAM-XXX
Sunrise
MP1500FAM-XXX
Momentum
V2000FAMU
Vega
ISD BC
Lutron
NFTV **
Nova
NTSTV-DV **
Nova T
DVTV
Diva
DVSTV **
Diva
V-600
w/GRX-TVI
Vareo
** WARNING! WHEN USING LUTRON NFTV OR NTSTV-DV LOW-VOLTAGE 0-10V DIMMERS, DO NOT SPECIFY OR INSTALL LUTRON PP-SERIES POWER PACKS. USE OF PP-SERIES POWER PACKS MAY CAUSE DAMAGE TO THE SmartSupply™ THAT IS NOT COVERED UNDER WARRANTY.
Page 18
www.kirlinlighting.com
MRI LUMINAIRE SYSTEM: Wiring Diagram
BLACK (-)
BLACK (–) CH 3
INSIDE MRI ROOM
RED (+) CH 3
Wire shields INSIDE room MUST be connected to room shield grounding bar.
BLACK (–) CH 1
DO NOT CONNECT wire shields to the luminaires.
BLACK (–) CH 2
RED (+)
Requires 16 AWG twisted pair shielded wire from SmartSupply (1400mA) to luminaires.
RED (+) CH 1
RED (+) CH 6
BLACK (–) CH 6
BLACK (-)
RED (+)
BLACK (–) CH 5
RED (+) CH 5
BLACK (–) CH 4
RED (+) RED (+) CH 4
BLACK (-)
Use of both Kirlin SmartSupply (1400mA) and SmartFilter are required to maintain Kirlin warranty.
One 1500 or 2500 Lumen Series (20W or 35W) Luminaire on One Circuit
RED (+) CH 2
DO NOT CONNECT LED luminaires to energized driver.
Two 1500 Lumen Series (20W) Luminaires on One Circuit
ROOM SHIELD GROUNDING BAR
ROOM SHIELD
GREEN (–) CH 3
WHITE (+) CH 3
BLACK (–) CH 2
DO NOT CONNECT wire shields OUTSIDE room to room shield grounding bar.
RFI-3100D
RED (+) CH 2
Requires 16 AWG twisted pair shielded wire from SmartSupply (1400mA) to luminaires.
WHITE (+) CH 1
BLACK (–) CH 6
RED (+) CH 6
GREEN (–) CH 5
WHITE (+) CH 5
BLACK (–) CH 4
RFI-3100D
RED (+) CH 4
SmartFilter™
OUTSIDE MRI ROOM
GREEN (–) CH 1
SmartFilter™
Electrical Input: 115-277VAC / 50-60Hz isolated circuit only. Maximum input voltage 290V.
ZONE 4 (NOT USED)
ZONE 1
ZONE 3
ZONE 2
SmartSupply™ LPS-1220A*
* DO NOT MOUNT OR CONNECT SmartSupply (1400mA) to room shield.
For more information on Kirlin’s SmartLED™ MRI lighting systems, including specification sheets and owner’s manuals (including installation instructions and wiring diagrams), please visit www.kirlinlighting.com and go to your MyKirlin portal. www.kirlinlighting.com
Page 19
MRI LUMINAIRE SYSTEM: Design Guide Ceiling Height Recommended Luminaires
Lower Ceilings (8’-9’)
Higher Ceilings (8’-12’)
Recessed Ambient
Task
Wide Specifiable Distribution Distribution
Patient Table (Aimable)
Surface Accent Wall Wash
Ambient Infection Control *
Wide Distribution
MRR-04200 MRR-06205 MRR-04220
1500
MRR-04225
Lumen Series (20W)
MRR-06230 MRR-06235 MRR-07240 MRS-04245 MRR-06420 MRR-06422 MRR-06424
2500
MRR-06426
Lumen Series (35W)
MRR-06427 MRR-08428 MSR-12440 MRS-08470 * Infection Control Key BioGard™ antimicrobial white finish standard. BioGard™ antimicrobial white finish (Option -BG) optional.
MRI LUMINAIRE / SCONCE SYSTEM: Check List
1. 2. 3. 4. 5.
Select the type and quantity of SmartLED™ Luminaires. See pages 10-13 for available models. Determine the quantity and remote location of the SmartSupply(s). See page 15. Determine the quantity of SmartFilters™. See page 15. Select dimming controls. See page 18. Determine the quantity and remote location (outside MRI shield) of the dimming controls.
See the LPS-1220A (MRI 1400mA SmartSupply™) and RFI-3100D (MRI SmartFilter™) OWNER’S Manuals for installation instructions and wiring diagrams AT www.kirlinlighting.com mykirlin portal.
Page 20
www.kirlinlighting.com
MRI Scenic Panel system: MRP-22290 SERIES • Selection of beautiful smooth panel artwork attractively and uniformly illuminated • Wave guide lens provides superior uniform illumination • Driverless, 20 watt, low voltage, Class II, DC powered. • Regressed trim provides architectural “skylight” effect • Ultra-shallow (2”) recessed aluminum housing
• • • •
IC
Lays into 2’ x 2’ grid ceiling 100-0.2% full range dimming 60,000 hours (L70) life Requires remote SmartSupply™ LPS-0700A and SmartFilter™ RFI-3100D. See page 25 for quantities required
MRP-22290
Regressed bevel provides architectural “skylight” effect.
Use multiple 2’ x 2’ Scenic Panels to create a soothing and attractive luminous ceiling.
23¾” sq [603mm]
Ultra-shallow (2”) aluminum housing requires minimal plenum space.
Use of both Kirlin SmartSupply™ LPS-0700A (700mA) and SmartFilter™ RFI-3100D are required to maintain Kirlin warranty. www.kirlinlighting.com
Page 21
MRI Scenic Panel system: Images Artwork Select artwork by adding the option code (i.e., -A01) of the respective artwork. For custom artwork, use Option -A99.
-A01
-A02
-A03
Custom Artwork (Customer supplied*)
-A05
-A06
-A04
Custom Artwork Preferred Image Resolution 1800 x 1800 pixels (or greater) per 24” x 24” panel. See “Overall Size and Orientation” table on page 23 for preferred image resolution for each configuration.
-A99
* For custom artwork, customer is responsible for supplying the artwork and obtaining the appropriate usage rights.
Dividing and Cropping Artwork When specifying size, orientation and artwork, consider how the image will be divided and cropped. For example:
-4x4
-6x4
-4x6
To see how your artwork will divided and cropped, consult factory. Page 22
www.kirlinlighting.com
MRI Scenic Panel system: Panel Configurations 1. 2. 3. 4. 5.
Use MRP-22290 as base catalog number, then add configurations and selections as follows. Choose overall size and orientation of the display using the “Overall Size and Orientation” table below. Select artwork with option codes (i.e., -A01). Consider how the artwork will be displayed. See “Dividing and Cropping Artwork”. Add appropriate quantity of SmartSupply™ LPS-0700A and SmartFilter™ RFI-3100D (details follow). Following the submission of your order, and before production, you will receive a proof for your review and approval.
Overall Size and Orientation Landscape
Portrait
Option
Preferred Resolution (Pixels)
1
-2x2
1800 x 1800
2’ x 4’
2
-4x2
3600 x 1800
4’ x 4’
4
-4x4
3600 x 3600
4’ x 6’
6
-6x4
5400 x 3600
6’ x 6’
9
-6x6
5400 x 5400
6’ x 8’
12
-8x6
7200 x 5400
8’ x 8’
16
-8x8
7200 x 7200
Nominal Dimensions
Fixture Qty
2’ x 2’
Arrangement
Arrangement
Option
Preferred Resolution (Pixels)
-2x4
1800 x 3600
-4x6
3600 x 5400
-6x8
5400 x 7200
-9x9 Specify number of panels and orientation of artwork.
Custom Size
SCENIC PANEL product SPECIFICATION EXAMPLE MRP-22290 -120 -4x6 -A01
Example: Scenic Panel Product Number
Specify Voltage
Artwork Option
Size and Orientation Option*
*-4x6 is not the same as -6x4, see above. www.kirlinlighting.com
Page 23
MRI SCENIC PANEL: SmartSupply™ DRIVER - REQUIRED • Full range 100% to 0.2% dimming and 3 dimming zones. See page 26 or consult factory for compatible controls. • Over wattage, cross channel, and electrical fast transient (EFT) protection. • Mounted outside MRI shield (not directly to shield). • Input: 115-277VAC / 50-60Hz rated. Dedicated 120VAC input recommended. For 277VAC input, proper line filtering and surge protection must be provided (by others). Maximum continuous input voltage is 290VAC. • Requires 16 AWG (minimum) twisted pair shielded wire from SmartSupply™ to luminaires. • FIVE YEAR Limited Warranty.
LPS-0700A
With Scenic Panels (20W) (12) Channels (Circuits) Maximum Distance Per Channel
(1) scenic panel / channel Up to (12) scenic panels / SmartSupply™ 150 feet
SmartFilter™ DC RFI / EMI FILTER - REQUIRED
• Industry leading RFI and EMI protection • Superior insertion loss of 100 dB (min.) • Fully protects 20 kHz to 1.0 GHz • One filter protects up to three Scenic Panel SmartSupply™ channels • Up to four filters required per Scenic Panel SmartSupply™ • Mounted on outside surface of MRI shield • FIVE YEAR Limited Warranty RFI-3100D 2011 IES Progress Report Selection
MRI SCENIC PANEL SYSTEM ORDERING EXAMPLE Quantity
Page 24
Product
Description
12
MRP-22290-120V-6x4-A03
Scenic Panels
1
LPS-0700A
Scenic Panel SmartSupply™ (700mA) driver (required)
4
RFI-3100D
SmartFilter™ DC RFI/EMI filter (required)
www.kirlinlighting.com
MRI Scenic Panel system: Typical Configuration Scenic Panels (20W)
RFI / EMI Shield Kirlin SmartLED™ Scenic Panels
• Up to (12) 20W scenic panels per SmartSupply • (1) scenic panel per SmartSupply channel (circuit). • Each color represents (1) set of (3) channels Kirlin SmartFilter™ RFI-3100D (Required) • (1) filter protects up to (3) SmartSupply channels. Each color represents (1) set of (3) channels • Up to (4) filters required per SmartSupply • Mounted on outside surface of MRI shield Kirlin SmartSupply™ LPS-0700A (Required) • (12) channels -- (1) scenic panel per channel -- Up to (12) scenic panels per SmartSupply • Max distance per channel -- 50’ with (1) scenic panel per channel • Mounted outside MRI shield (not directly to shield)
MRI Scenic Panel system: Check List 1. Select the quantity and layout of SmartLED™ scenic panels. See page 23. 2. Select the image. Consider how the image will be oriented, cropped and divided. See page 22. 3. Determine the quantity and remote location of the SmartSupply(s). See page 24. 4. Determine the quantity of SmartFilters™. See page 24. 5. Select dimming controls. See page 26. 6. Determine the quantity and remote location (outside MRI shield) of the dimming controls.
See the LPS-0700A (MRI Scenic Panel SmartSupply™) and RFI-3100D (MRI SmartFilter™) OWNER’S Manuals for installation instructions and wiring diagrams at www.kirlinlighting.com mykirlin portal.
www.kirlinlighting.com
Page 25
MRI Scenic Panel system: Typical Wiring Overview This wiring overview provides dimming control for zones 1, 2 and 3 simultaneously with a 0-10V DC dimmer* connected to the master 0-10V DC input of the SmartSupply™.
Shown with: • • • •
Use of both Kirlin SmartSupply (700mA) and SmartFilter are required to maintain Kirlin warranty.
(1) SmartSupply™ LPS-0700A (4) SmartFilters™ RFI-3100D (3) SmartLED™ Scenic Panels (1) Wall Box Dimmer*
Requires 16 AWG (minimum) twisted pair shielded wire from SmartSupply (700mA) to luminaires.
CHANNELS 7-9 CHANNELS 7-9 CHANNELS 10-12
JUNCTION BOX
SmartSupply™ LPS-0700A (Output)
RFI-3100D
SmartFilter™ CHANNELS 10-12
CHANNELS 1-3
CHANNELS 1-3 CHANNELS 4-6
SmartFilter™
SmartFilter™ RFI-3100D
CHANNELS 4-6
SmartFilter™ RFI-3100D
SmartFilter™ RFI-3100D
GREY
CHANNEL 3
SmartSupply™ LPS-0700A (Input)
CHANNEL 2
CHANNEL 1
PURPLE
Scenic Panels
WALL BOX DIMMER*
LINE
AC INPUT
NEUTRAL
Wall dimmer must be mounted OUTSIDE of room shield. Dimming control wires MUST NOT connect through the filter.
* Kirlin recommends using the following compatible 0-10V DC dimmers: Leviton
Lightolier
Acuity
IP710-DLX ZP600FAM-XXX
Sunrise
MP1500FAM-XXX
Momentum
V2000FAMU
Vega
ISD BC
Lutron
NFTV **
Nova
NTSTV-DV **
Nova T
DVTV
Diva
DVSTV **
Diva
V-600
w/GRX-TVI
Vareo
** WARNING! WHEN USING LUTRON NFTV OR NTSTV-DV LOW-VOLTAGE 0-10V DIMMERS, DO NOT SPECIFY OR INSTALL LUTRON PP-SERIES POWER PACKS. USE OF PP-SERIES POWER PACKS MAY CAUSE DAMAGE TO THE SMARTSUPPLY™ THAT IS NOT COVERED UNDER WARRANTY.
Page 26
www.kirlinlighting.com
MRI Scenic Panel system: Wiring Diagram DO NOT CONNECT LED luminaires to energized driver. Use of both Kirlin SmartSupply (700mA) and SmartFilter are required to maintain Kirlin warranty. Requires 16 AWG (minimum) twisted pair shielded wire from SmartSupply (700mA) to luminaires.
BLACK (-)
BLACK (–) CH 3
RED (+) CH 3
BLACK (–) CH 2
RED (+) CH 2
INSIDE MRI ROOM
BLACK (–) CH 1
Wire shields INSIDE room MUST be connected to room shield grounding bar.
RED (+) CH 1
BLACK (–) CH 12
DO NOT CONNECT wire shields to the luminaires.
RED (+) CH 12
BLACK (–) CH 11
RED (+) CH 11
BLACK (–) CH 10
RED (+) CH 10
RED (+)
One Smar tLED™ Scenic Panel Per Circuit
ROOM SHIELD GROUNDING BAR
ROOM SHIELD
BLACK (–) CH 3
GREEN (+) CH 3
BLACK (–) CH 2
DO NOT CONNECT wire shields OUTSIDE room to room shield grounding bar.
RED (+) CH 2
Requires 16 AWG (minimum) twisted pair shielded wire from SmartSupply (700mA) to luminaires.
RFI-3100D
WHITE (+) CH 1
BLACK (–) CH 12
RED (+) CH 12
GREEN (–) CH 11
WHITE (+) CH 11
BLACK (–) CH 10
RFI-3100D
RED (+) CH 10
SmartFilter™
OUTSIDE MRI ROOM
BLACK (–) CH 1
SmartFilter™
Electrical Input: 115-277VAC / 50-60Hz isolated circuit only. Maximum input voltage 290V.
SmartFilter™ RFI-3100D
ZONE 4
ZONE 1
ZONE 3
ZONE 2
SmartSupply™ LPS-0700A*
To SmartFilter™
RFI-3100D SmartFilter
* DO NOT MOUNT OR CONNECT SmartSupply (700mA) to room shield.
For more information on Kirlin’s SmartLED™ MRI lighting systems, including specification sheets and owner’s manuals (including installation instructions and wiring diagrams), please visit www.kirlinlighting.com and go to your MyKirlin portal. www.kirlinlighting.com
Page 27
SECTION II: exam lighting
(recessed Downlight / Adjustable)
Three Levels of Infection Control Protection HIGHER QUALITY LIGHT • Select delivered lumens from 1500-5000 in downlight or adjustable designs. • Choose the color of your light: 2700K (very warm white), 3000K (warm white), 3500K (neutral white, standard), 4100K (cool white) or 5000K (daylight white). • High CRI available (Option -HC) for accurate tissue color rendering: CRI 90+ with high R9 (Red), R13 and R15 (Skin Colors).
A SAFER ENVIRONMENT • Fully recessed fixtures provide an open work space. • Compact and smooth trim and lens are easy to clean and disinfect. • BioGard™ antimicrobial finish inhibits the growth of pathogens. • IP65 sealed trims minimize the likelihood of pathogens passing through the fixture. • ISO 5 Class 100 sealed fixtures for “cleanroom” applications. • Impact resistant lenses available (ideal for emergency departments and psychiatric units).
GREATER PERFORMANCE • Dimming down to 10% permits staff to finely tune light levels for specific tasks, each clinician and time of day. • Higher delivered lumens and 50% energy savings over fluorescent troffers. • Multi-light system removes debilitating shadows.
Level 1 Protection
oG
Bi
Lensed, BioGard™ antimicrobial finish
oG
IP65 sealed trim, BioGard™ antimicrobial finish
Bi
oG
Bi
IP65 sealed trim, vandal resistant, BioGard™ antimicrobial finish
Level 3 Protection
oG
Bi
ISO 5/class 100 sealed “cleanroom” fixture, BioGard™ antimicrobial finish
Level 3 + Protection
ISO 5/class 100 sealed fixture, vandal resistant, BioGard™ antimicrobial finish
Page 28
IP65
d™ ar
oG
Bi
d™ ar
IP65
ISO 5
100
CLEANROOM
IP65
VR
IP65
d™ ar
CLASS
Level 2 + Protection
d™ ar
ISO 5 CLASS
Level 2 Protection
d™ ar
100
CLEANROOM
VR
www.kirlinlighting.com
SECTION II: exam lighting
(recessed Downlight / Adjustable)
Infection Control
Application
Function
Aperture (Inches)
Level 1 Protection
Antimicrobial BioGard™ Finish Regressed Lens
Downlight
7
Level 1 Protection
Antimicrobial BioGard™ Finish Regressed Lens
Adjustable
Level 1 Protection
Antimicrobial BioGard™ Finish Regressed Lens
Downlight
4x9
Level 1 Protection
Antimicrobial BioGard™ Finish Regressed Lens
Downlight
5 x 11
Level 2 Protection
IP65 Rated BioGard™ Finish Regressed Lens
Downlight
Level 2 Protection
IP65 Rated BioGard™ Finish Regressed Lens
Adjustable
Level 2+ Protection
IP65 Rated - BioGard™ Tamper Resistant Psychiatric/ED
Downlight
Level 2+ Protection
IP65 Rated - BioGard™ Tamper Resistant Psychiatric/ED
Adjustable
Level 3 Protection
Class 100 Cleanroom BioGard™ Finish OR/Hybrid OR
Downlight
7
Level 3 Protection
Class 100 Cleanroom BioGard™ Finish OR/Hybrid OR
Downlight
8
Level 3 Protection
Class 100 Cleanroom BioGard™ Finish OR/Hybrid OR
Adjustable
Level 3+ Protection
Class 100 Cleanroom Tamper Resistant BioGard™ Finish Psychiatric/OR
Downlight
Level 3+ Protection
Class 100 Cleanroom Tamper Resistant BioGard™ Finish Psychiatric/OR
Product #
Performance Lumens
Watts
MRR-07500-5000L
5000
55
MRR-07500-3500L
3500
42
MRR-07505-5000L
5000
55
MRR-07505-3500L
3500
42
MRT-04510-5000L
5000
70
MRT-05515-7000L
7000
84
MRT-05515-5000L
5000
70
MRR-08530-5000L
5000
55
MRR-08530-3500L
3500
42
MRR-08535-5000L
5000
55
MRR-08535-3500L
3500
42
MRV-08540-5000L
5000
55
MRV-08540-3500L
3500
42
MRV-08545-5000L
5000
55
MRV-08545-3500L
3500
42
MRR-07550-1500L
1500
15
MRR-08555-5000L
5000
55
MRR-08555-3500L
3500
42
MRR-08558-5000L
5000
55
MRR-08558-3500L
3500
42
MRV-07560-1500L
1500
15
MRV-08565-5000L
5000
55
MRV-08565-3500L
3500
42
Page
7 30
8 31
8
8 31
8
32
8
7
32
Downlight
8
INSTALLATIONS, options and ordering
33-35
PLEASE VISIT www.kirlinlighting.com FOR KIRLIN TUNGSTEN HALOGEN EXAM LIGHTING PRODUCTS IN KIRLIN’S PATIENT EXAM & HEALTHCARE LIGHTING CATALOG (BULLETIN 08HC). www.kirlinlighting.com
Page 29
SECTION II: exam lighting
Level 1 Protection
Lensed, BioGard™ antimicrobial finish
oG
Bi
d™ ar
7” MAXIMUM PERFORMANCE (-5000L Series)
Downlight
Cone of Light ▲
4827 LUMENS 55W
Dist. 6 8 10 12 14 16
FC 247.0 139.0 89.1 61.9 45.5 34.8
439 405
305
195
Dia. 3.5 4.7 5.9 7.1 8.3 9.4
fc on Task: 8’ Ceiling 3’6” Work Plane
MRR-07500-5000L MRR-07500-3500L
Narrow Flood (Standard) Shown. Medium Flood (-MFL) Optional
7”
Adjustable
Patient Room Cardiac Cath Labor and Delivery Radiology PreOp / PostOp Veterinary Autopsy
MAXIMUM PERFORMANCE (-5000L Series) 740 614
375
Applications:
210
4623 LUMENS 55W
fc on Task: 8’ Ceiling 3’6” Work Plane
MRR-07505-5000L MRR-07505-3500L
Narrow Flood (Standard) Shown
4” x 9”
▲ Cone of Light Key
PERFORMANCE (-5000L Series) Cone of Light ▲
5249 LUMENS 2 x 35W
Dist. 6 8 10 12 14 16
FC 709.0 399.0 255.0 177.0 130.0 99.7
1245 984
515
Ft. Distance from fixture FC Footcandles at nadir (0°) Dia. Circle of light at 50% of FC
213
Dia. (in ft.) shown is where FC value is half the FC at nadir.
Dia. 2.2 2.9 3.6 4.3 5.1 5.8
Downlights
fc on Task: 8’ Ceiling 3’6” Work Plane
Applications:
MRT-04510-5000L
Narrow Flood (Standard) Shown
5” x 11”
Patient Room ICU / NICU Labor and Delivery PreOp / PostOp Veterinary Autopsy
MAXIMUM PERFORMANCE (-7000L Series) Cone of Light ▲
7089 Lumens 2 x 42W
Dist. 6 8 10 12 14 16
FC 1200.0 676.0 433.0 300.0 221.0 169.0
2129 1610 684
239
Dia. 1.9 2.5 3.2 3.8 4.4 5.1
fc on Task: 8’ Ceiling 3’6” Work Plane
MRT-05515-7000L MRT-05515-5000L
Page 30
Narrow Flood (Standard) Shown
www.kirlinlighting.com
SECTION II: exam lighting 8”
Level 2 Protection
Downlight
5298 Lumens 55W
Dist. 6 8 10 12 14 16
FC 298.0 168.0 107.0 74.6 54.8 42.0
530
484
357
IP65
220
Dia. 3.4 4.5 5.7 6.8 7.9 9.1
fc on Task: 8’ Ceiling 3’6” Work Plane
Narrow Flood (Standard) Shown. Medium Flood (-MFL) Optional
8”
513
Applications: ICU / NICU PreOp / PostOp Autopsy Veterinary PT / CT Scan Infection Control Areas
MAXIMUM PERFORMANCE (-5000L Series) 1143 969
Adjustable
d™ ar
MAXIMUM PERFORMANCE (-5000L Series) Cone of Light ▲
MRR-08530-5000L MRR-08530-3500L
oG
Bi
IP65 sealed trim, BioGard™ antimicrobial
220
4796 Lumens 55W
fc on Task: 8’ Ceiling 3’6” Work Plane
MRR-08535-5000L MRR-08535-3500L
Narrow Flood (Standard) Shown
Level 2 + Protection
oG
Bi
IP65 sealed trim, vandal resistant, BioGard™ antimicrobial finish
8”
4749 Lumens 55W
Dist. 6 8 10 12 14 16
FC 243.0 137.0 87.6 60.8 44.7 34.2
432
396
295
Dia. 3.5 4.7 5.8 7.0 8.1 9.3
Applications:
Narrow Flood (Standard) Shown. Medium Flood (-MFL) Optional
8”
Emergency Psychiatric Prison / Jail PreOp / PostOp Veterinary Patient Room
MAXIMUM PERFORMANCE (-5000L Series) 1169 963
Adjustable
VR
187
fc on Task: 8’ Ceiling 3’6” Work Plane
MRV-08540-5000L MRV-08540-3500L
IP65
MAXIMUM PERFORMANCE (-5000L Series) Cone of Light ▲
Downlight
d™ ar
441
162
4185 Lumens 55W
fc on Task: 8’ Ceiling 3’6” Work Plane
MRV-08545-5000L MRV-08545-3500L
Narrow Flood (Standard) Shown
▲ Cone of Light Key
Ft. Distance from fixture FC Footcandles at nadir (0°) Dia. Circle of light at 50% of FC Dia. (in ft.) shown is where FC value is half the FC at nadir.
www.kirlinlighting.com
Page 31
Level 3 Protection
ISO 5/class 100 sealed fixture
Cone of Light ▲
1553 Lumens
IC
Dist. 6 8 10 12 14 16
FC 89.3 50.2 32.1 22.3 16.4 12.6
158 145
110
CLEANROOM
Dia. 3.5 4.7 5.9 7.1 8.2 9.4
fc on Task: 8’ Ceiling 3’6” Work Plane
Narrow Flood (Standard) Shown. Medium Flood (-MFL) Optional
MAXIMUM PERFORMANCE (-5000L Series)
8”
Cone of Light ▲
5298 Lumens 55W
Dist. 6 8 10 12 14 16
FC 298.0 168.0 107.0 74.6 54.8 42.0
530
484
Applications:
357
220
Operating Room Hybrid OR Intraoperative OR CCU Cleanroom Cardiac Cath Interventional Radiology
Dia. 3.4 4.5 5.7 6.8 7.9 9.1
fc on Task: 8’ Ceiling 3’6” Work Plane 2013 IES Progress Report Selection
Narrow Flood (Standard) Shown. Medium Flood (-MFL) Optional
MAXIMUM PERFORMANCE (-5000L Series)
8” Adjustable
1143 969
513
220
4796 Lumens 55W
MRR-08558-5000L MRR-08558-3500L
fc on Task: 8’ Ceiling 3’6” Work Plane
Narrow Flood (Standard) Shown
Level 3 + Protection
oG
Bi
ISO 5/class 100 sealed fixture, vandal resistant, BioGard™ antimicrobial finish
Cone of Light ▲
1468 Lumens 20W
MRV-07560-1500L
IC
Dist. 6 8 10 12 14 16
FC 70.8 39.8 25.5 17.7 13.0 10.0
125 117
92
ISO 5
100
CLEANROOM
VR ▲ Cone of Light Key
61
Ft. Distance from fixture FC Footcandles at nadir (0°) Dia. Circle of light at 50% of FC
Dia. 3.8 5.0 6.3 7.5 8.8 10.0
Dia. (in ft.) shown is where FC value is half the FC at nadir.
MAXIMUM PERFORMANCE (-5000L Series)
4749 Lumens 55W
Dist. 6 8 10 12 14 16
FC 243.0 137.0 87.6 60.8 44.7 34.2
432
396
295
Applications: Emergency Psychiatric Prison / Jail PreOp / PostOp Veterinary Patient Room
Narrow Flood (Standard) Shown. Medium Flood (-MFL) Optional
Cone of Light ▲
Page 32
IP65
fc on Task: 8’ Ceiling 3’6” Work Plane
8”
MRV-08565-5000L MRV-08565-3500L
d™ ar
PERFORMANCE (-1500L Series)
7”
Downlights
ISO 5
100
70
CLASS
Downlights
20W
MRR-08555-5000L MRR-08555-3500L
IP65
d™ ar
PERFORMANCE (-1500L Series)
7”
MRR-07550-1500L
oG
Bi
CLASS
SECTION II: exam lighting
187
Dia. 3.5 4.7 5.8 7.0 8.1 9.3
fc on Task: 8’ Ceiling 3’6” Work Plane
Narrow Flood (Standard) Shown. Medium Flood (-MFL) Optional
www.kirlinlighting.com
KIRLIN LED exam lighting Outperforms antiquated troffers Performance
Reliability
• Over 50% energy savings • Higher delivered lumens • Fewer luminaires, lower cost • Exceeds IES recommended light levels • Better illumination uniformity; no glare • Instant on, reliable dimming
Infection Control
• BioGard™ antimicrobial finish • Smaller lens and trim for faster cleaning • Award winning cleanroom 2013 IES Progress versions offered
Installation and Maintenance
Report Selection
• IEC/EN 60601-1-2 medical listing • FCC Part 15 EMI/RFI emissions • Internal emergency battery packs available. Deliver 500 or 1000 lumens. Run time 90+ minutes. See options -EM and -EMH. • SmartSupply™ remote driver (LPS-1220A) available. Full range 100% to 0.2% dimming and 3 dimming zones. Drives up to (12) -1500L luminaires or (3) -5000L Level 3 luminaires. See Option -SS and page 35. • SmartPower™ emergency inverter (EMI-21220) available. Provides 100% lumen output for up to two hours. See page 35.
• Maintenance-free LEDs • Smaller size for easier installation • Shallow depth housings fit anywhere Zone
Lighting Performance
Location
fc
1
OR Table
800
2
Near OR Table
200
3
OR Perimeter
100
Luminaires*
Fixture Qty
MRR-08558-5000L
6
MRR-08555-5000L
15
* See www.kirlinlighting.com for specification sheets.
Operating Room Zones
5' - 6"
30' - 0”
2' - 7"
734 880 734
Zone 2 200 fc
6' - 0"
734 880 734
6' - 6"
633 821 633
Zone 1 800 fc
6' - 0"
Footcandles on Operating Table
531 710 531
2' - 7"
Zone 3 100 fc
633 821 633
24' - 0” 531 710 531
Zone 2 200 fc
www.kirlinlighting.com
Page 33
SECTION II: exam lighting Two Adjustable Exam Lights
Two Adjustable Exam Lights in NICU
Placed 4’ apart on centers over the head and foot of the bed.
4’ [112cm]
LUMINAIRE
Typical Installations Placed over the foot corners of the bed.
23° (35° Max)
22° (35° Max) SITE
8’ [244cm]
4’ [112cm]
LUMINAIRES
2’ 8‘’ [81cm] 30°
SITE 8’ [244cm] 3’ 4” [101cm]
3’ [91cm]
Front View
One Adjustable Exam Light
Side View
One Fixed Exam Light
Placed over the head (or foot) of the bed to avoid obstructions in ceiling.
Placed over center of the bed.
LUMINAIRE
LUMINAIRE
22° (35° Max) SITE
8’ [244cm]
3’ [91cm]
3’ [91cm]
SECTION II: exam lighting Input Power: SPECIFY -120 120V (50-60Hz) input and thermal protector. -277 277V (50-60Hz) input and thermal protector. -97 Specify other voltage. Consult factory.
LED Power Supply -29 Two wire full range (100-1%) PWM dimming instead (Lutron). 120V only. Not available with Option -EI. -39 Three wire full range (100-1%) PWM dimming instead (Lutron). -EI REMOTE emergency inverter for 45% of rated lumens for -5000L, 55% for -3500L or 100% for -1500L. Run time: 90+ minutes. 120 or 277V, 60 Hz input only. Specify voltage. Not for use with -SS SmartSupply™ driver or with Option -29. -EM INTERNAL emergency battery pack. Delivers 500 lumens. Run time: 90+ minutes.
SITE
8’ [244cm]
POPULAR Options
-EMH INTERNAL emergency battery pack. Delivers 1000 lumens. Run time: 90+ minutes. Marked spacings installation may be required; refer to specification sheet. -ER REMOTE emergency battery pack. Delivers 500 lumens. Run time: 90+ minutes. -ERH REMOTE emergency battery pack. Delivers 1000 lumens. Run time: 90+ minutes. -SS Remote mounted Kirlin SmartSupply™ driver (instead of standard internal driver), sold separately. Order LPS-1220A (0-10V analog with 100-0.2% PWM dimming). Available for -1500L and -5000L lumen series luminaires only. Refer to page 35 and LPS-1220A specification sheet and owner’s manual at www.kirlinlighting.com.
Color Temperature (CCT) -27K Color temperature 2700°K instead. 85 CRI. -30K Color temperature 3000°K instead. 85 CRI.
(See specification sheets for availability and details.) Page 34
-41K Color temperature 4100°K instead. 85 CRI. -50K Color temperature 5000°K instead. 85 CRI. -HC 90+ CRI instead. 2700° or 3000°K only. Reduces output by ~15%.
Optics (-NFL Standard) -MFL Medium flood distribution instead.
Trims -32 -45 -46
White oversize trim ring. Specify O.D. Gasket between trim flange and ceiling. Gasket between trim and lens.
Other -99 -FD -FS
Special modification. Consult factory. Dual circuit fusing. For use only with Option -EI and either -5000L or -3500L lumen series. In-line fusing. Not for use with Option -EI and either -5000L or -3500L lumen series: See -FD instead.
www.kirlinlighting.com
SmartSupply™ REMOTE DIMMING DRIVER - OPTIONAL • Full range 100% to 0.2% dimming and 3 dimming zones. • Drives up to (12) -1500L, or up to (3) -5000L luminaires. • Over wattage, cross channel, and electrical fast transient (EFT) protection. • Input: 115-277VAC / 50-60Hz rated. Dedicated 120VAC input recommended. For 277VAC input, proper line filtering and surge protection must be provided. Maximum continuous input voltage is 290VAC. • Requires 16 AWG (minimum) twisted pair shielded wire from SmartSupply™ to luminaires. • FIVE YEAR Limited Warranty.
LPS-1220A
See LPS-1220A Owner’s Manual for more information, including compatible controls and wiring diagrams, at www.kirlinlighting.com MyKirlin Portal.
SmartPower™ EMERGENCY BACKUP SYSTEM - OPTIONAL
• High efficiency pure sine wave inverter • Operates up to (6) -5000L series fixtures • 100% light output for up to two hours • 120 / 277V, 60Hz input • Less than 50 milliseconds transfer time
• May be mounted up to 1000 feet from load • UL 924 Listed. Meets or exceeds all NEC and Life Safety Code Emergency Lighting Requirements • THREE YEAR Limited Warranty
EMI-21220
Luminaire Ordering EXAMPLE MUST SPECIFY
OPTIONAL
Product Number
Voltage
Options
MRV-08565-5000L MRV-08565-3500L
-120 (120 volts) -277 (277 volts) -97 (Specify other)
See “Options” on prior page
Ordering Example: MRV-08565-5000L-120-30K-MFL
LUMEN SERIES AVAILABLE Lumen Series Code
Nominal Lumens
-5000L
5000 Lumens
-3500L
3500 Lumens
-1500L
1500 Lumens
www.kirlinlighting.com
Page 35
SECTION III: motorized exam lighting & Controls HIGHER QUALITY LIGHT with OPTeCOLOR™ • Choose the color of your light: 3500K (Neutral white: Standard), 4100K (Cool white: Option -41K) or 5000K (Daylight white: Option -50K) • Ultra-high 95+ CRI with high R9 (Red), R13 and R15 (Skin Colors) for accurate tissue color rendering. • High illuminance for deep cavities or challenging positions. Up to 9000 delivered footcandles from 5 feet, dimmable to 10%.
High CRI
Common CRI
GREATER CONTROL • Independent control of each lighthead permits adjustable pattern of light and dual task illumination. • Intuitive and responsive controls allow for quick and accurate adjustment of direction and intensity of the light. • Angles of illumination up to 60° ensure the task is properly illuminated regardless of the task location or clinicians’ position. • Dimming down to 10% permits staff to finely tune levels, as needed.
A SAFER ENVIRONMENT • Recessed fixtures provide an open work space. The light remains recessed, protecting the patient from contaminants near or above the ceiling. • IP65 trims with BioGard™ antimicrobial finish protect against pathogens.
IP65
G io
d™ ar
B
IES Progress Report Selections
GREATER COMFORT • Cool LED illumination does not project heat toward the room, assuring patient and practitioner comfort and avoiding tissue desiccation. • Inconspicuous: Fully recessed fixtures provide a more residential atmosphere; Remote control does not need to be used near the patient. • Remote control technology employs invisible infrared signal, preventing the triggering of photosensitive conditions (migraines, epileptic seizures, stress).
DEPENDABILITY • Redundancy of LED circuits ensures illumination at all times. Redundancy of controls (wall or remote) ensures 24/7 adjustability of illumination intensity and position. • Impact resistant design protects remote control. • Loss deterring beeper feature on the remote control reminds staff to return the remote to its “home plate” on the wall control panel.
Exclusive Three Year Warranty • Designed and Produced in U.S.A. • UL, C-UL (Canada) Listed Page 36
www.kirlinlighting.com
SECTION III: motorized exam lighting & Controls
INFRALED® 60 • INFRALED® • OPTeMED™ Name
Application
Design
Delivered Lumens
Total Watts
Aperture (Inches)
Product #
Remote Control and Wall Control with recessed motorized luminaire(s)
38-41
INFRALED® 60
LDRP/OB
Pair
8000
280
17
MRS-17600
INFRALED
Intraoperative OR Hybrid OR ICU/CCU Cardiac Cath
Pair
6000
140
12
MRR-12620
®
Page
38-39
40-41
INFRALED®
ED Patient Room
Single
3000
70
12
MRR-12622
Wall Control with recessed motorized luminaire(s)
OPTeMED™
PICU/NICU ED Trauma
42-43
Pair
6000
140
12
MRR-12640
42-43
OPTeMED™
PICU/NICU Patient Room Autopsy
Single
3000
70
12
MRR-12642
PLEASE VISIT www.kirlinlighting.com FOR KIRLIN TUNGSTEN HALOGEN MOTORIZED EXAM LIGHTING IN KIRLIN’S PATIENT EXAM & HEALTHCARE LIGHTING CATALOG (BULLETIN 08HC).
www.kirlinlighting.com
Page 37
SECTION III: motorized exam lighting THE BIRTHING LIGHTING SYSTEM / SOLUTION LED Remote Controlled Motorized 60° High Angle Recessed Patient Low Voltage Lighting System MRS-17600 (Two Light System) 2015 IES Progress Report Selection
FEATURES • Light delivered at angles up to 60° to match the clinician’s line of site for superior illumination of the birthing canal. • Four OPTeCOLOR™ LED light heads per system deliver up to 6000 fc with no heat in the beam. • OPTeCOLOR™ LEDs provide 95+ CRI (with high R9, R13 and R15) for excellent color rendering of blood, tissue and skin tones. 60,000 hour life (L70) dramatically reduces maintenance frequency and cost. • Redundancy of controls, electronic components and circuitry ensures control of fixtures and at least 75% illumination at all times. • Fully recessed fixtures with BioGard™ antimicrobial trims are unobtrusive and inconspicuous, providing a safe and open space for staff and a home-like atmosphere for patients. • Full control of lighting system (direction, intensity, power) from low voltage, Class 2 remote and wall controls. • Remote control uses invisible and safe infrared signals. Impact resistant design protects remote from common mishaps. Loss deterring beeper reminds staff to return the remote to the wall control when finished. • Smooth surfaces and minimal surface areas (both fixtures and controls) are easy to clean and disinfect. • Kirlin’s exclusive three year limited warranty (one year remote control). • Includes 2’ x 2’ ceiling pan for easy installation in T-bar ceiling or see Option -47. oG
Bi
d™ ar
Applications • Birthing Suites
• Post-partum
• Labor & Delivery
• OB/GYN/LDRP 22” SQ (559mm)
11-1/4” (286mm)
60° 18-3/8” (467mm)
LEFT LIGHT LOW BATTERY INDICATOR
INFRALED ® 60
FOOT
RIGHT LIGHT
LED RECESSED ADJUSTABLE MEDICAL LIGHTING SYSTEM
HEAD
ADJUST POSITION
BRIGHT
SELECT LIGHT
ON OFF DIM
5” (127mm)
DIRECTIONS FOR USE
HEAD
1 Turn system ON
STORE REMOTE CONTROL HERE
2 SELECT LIGHT to be adjusted
ADJUST POSITION
3 ADJUST POSITION 4 Repeat steps 2 - 3 for additional light
Beeper is activated in 60 minute intervals unless remote is used or returned to wall control storage area
SELECT LIGHT
FOOT
BRIGHT
6 Turn system OFF and store remote control
INFRARED REMOTE CONTROL FOR
INFRALED ® 60
5 Adjust BRIGHT / DIM
5-5/8” (143mm)
4-1/2” (114mm)
ON OFF DIM
www.kirlinlighting.com
Detroit, MI • www.kirlinlighting.com
2-3/4” (70mm)
8-1/8” (206mm)
2-1/2” (64mm)
Popular Options Input Power: SPECIFY
Color Temperature (CCT)
-120 120V (50-60Hz) input and thermal protector. -58 277/120 volt stepdown transformer for 277 volt line input, prewired into each fixture; with 277 volt thermal protector. -97 For other input supply voltages, consult factory. -98 347/120 volt stepdown transformer for 347 volt line input, prewired into each fixture; with 120 volt thermal protector. Adds 10 watts to each fixture load.
-41K 4100°K instead of 3500°K. 95+ CRI. -50K 5000°K instead of 3500°K. 95+ CRI.
Page 38
Trim and Other -47 -87 -94
Plaster frame bottom pan. For installation in hard ceilings. Custom length (> 35 feet) plenum rated wall control cables (4). Consult factory. Custom color self-flanged flare trim instead. Consult factory.
-99 -BI -RC -RS -SE
Special modification. Consult factory. Beeper (remote control) inactivated by factory. Extra remote control. Remote infrared sensor with 35’ cable. Ceiling mount typical. Fixtures modified for seismic anchorage (by others). Meets California OSHPD and International Building Codes.
(See specification sheets for availability and details.) www.kirlinlighting.com
SECTION III: motorized exam lighting THE BIRTHING LIGHTING SYSTEM / SOLUTION Recommendations for Typical Installation •
Fixtures placed 4’ apart (on centers) to project light on either side of practitioner’s head and over practitioner’s shoulders.
•
Fixture setback from break in bed determined by ceiling height, and position and height of practitioners.
•
•
Ideal angle of illumination should be between 50°55° for sitting practitioners which provides future flexibility should task location change. Consult factory for assistance in determining ideal location of fixtures.
Typical Side View: 8’ Ceiling Height LUMINAIRE (ONE SHOWN)
LOW VOLTAGE CABLE 35’ [1067cm] WALL CONTROL & BACK BOX SITE
ANGLE of ILLUMINATION
8’ [244cm] CEILING HEIGHT
TASK HEIGHT 3’ [91cm]
3.5’ [107cm]
6’ 7” [201cm]
Wall control placed in unobstructed location and within line of sight from practitioner's location.
SETBACK
Typical Top View: 8’ Ceiling Height Recommended Fixture Setback / Location with Angle of Illumination and Light Levels
SITE
SPACING
(ON CENTER)
Sitting Practitioners
Ceiling Height
Setback from Break in Bed
Photometric testing by ITL (Boulder, CO) ITL Test No. 84926
Angle of Illumination
Footcandles on Task
7.0
Optimal
54.5
5105
6.0
Alternative
50.2
6052
8.0
Optimal
55.5
4080
7.0
Alternative
51.8
4851
8.0
Optimal
53.1
3850
4’ [122cm]
SETBACK 6’ 7” [201cm]
8
Sitting Practitioners 4' Spacing • 3' Work Plane • 53° Angle of Illumination
8.5
9
SITE
SPACING
7.0
Alternative
49.4
4515
9.0
Optimal
54.2
3163
8.0
Alternative
50.9
3622
9.0
Optimal
52.1
2997
9.5
10
Typical Top View: 9' Ceiling Height
Alternative setback provided for room configurations that do not allow fixture placement in optimal setback location. For additional setback locations, consult factory.
www.kirlinlighting.com
(ON CENTER)
4’ [122cm]
SETBACK 6’ 7” [201cm]
Sitting Practitioners 4' Spacing • 3' Work Plane • 53° Angle of Illumination
Page 39
SECTION III: motorized exam lighting LED Remote Controlled Motorized Recessed Patient Low Voltage Lighting System MRR-12620 (Two Light System) MRR-12622 (One Light System) FEATURES • OPTeCOLOR™ LEDs deliver up to 10,000 fc with no heat in the beam. • OPTeCOLOR™ LEDs provide 95+ CRI (with high R9, R13 and R15) for excellent color rendering of blood, tissues and skin tones. 60,000 hour life (L70) dramatically reduces maintenance frequency and cost. • Light delivered at angles up to 35° (50° with Option -81) with full 360° rotation to provide coverage of the patient. • Redundancy of controls, electronic components and circuitry ensures control of lights and at least 75% (MRR12620) illumination at all times. • Fully recessed fixtures with BioGard™ antimicrobial trims are unobtrusive and inconspicuous, providing a safe and open space for staff and a home-like atmosphere for patients. • Full control of lighting system (direction, intensity, power) from low voltage , Class 2 remote and wall controls. Independent direction control of each light. Light beams may be aimed at 2 separate sites or superimposed. • Remote control uses invisible and safe infrared signals. Impact resistant design protects remote from common mishaps. Loss deterring beeper reminds staff to return the remote to the wall control when finished. • Smooth surfaces and minimal surface areas (both fixtures and controls) are easy to clean and disinfect. • Kirlin’s exclusive three year limited warranty (one year remote control). • Easily installs in T-bar or drywall ceiling with mounting hardware provided.
Applications • ICU/CCU
• ED
• NICU/PICU
• CATH LAB 22” SQ (559mm)
12” (305mm)
35° 11-3/8” (289mm)
LEFT LIGHT LOW BATTERY INDICATOR
FOOT
BRIGHT
SELECT LIGHT
ON OFF DIM
5” (127mm)
RIGHT LIGHT
DIRECTIONS FOR USE
HEAD
1 Turn system ON
STORE REMOTE CONTROL HERE
2 SELECT LIGHT to be adjusted
ADJUST POSITION
Beeper is activated in 60 minute intervals unless remote is used or returned to wall control storage area
3 ADJUST POSITION 4 Repeat steps 2 - 3 for additional light
SELECT LIGHT
FOOT
BRIGHT
INFRALED ®
5 Adjust BRIGHT / DIM 6 Turn system OFF and store remote control
INFRARED REMOTE CONTROL FOR
5-5/8” (143mm)
4-1/2” (114mm)
ON OFF DIM
www.kirlinlighting.com
Detroit, MI • www.kirlinlighting.com
2-3/4” (70mm)
Popular Options
2-1/2” (64mm)
8-1/8” (206mm)
-94
Input Power: SPECIFY
Color Temperature (CCT)
-120 120V (50-60Hz) input and thermal protector. -58 277/120V stepdown transformer for 277V line input, prewired into each fixture; with 277V thermal protector. -97 For other input supply voltages, consult factory. -98 347/120V stepdown transformer for 347V line input, prewired into each fixture; with 120V thermal protector. Adds 10 watts to each fixture load.
-41K 4100°K instead of 3500°K. 95+ CRI. -50K 5000°K instead of 3500°K. 95+ CRI.
Page 40
INFRALED ® LED RECESSED ADJUSTABLE MEDICAL LIGHTING SYSTEM
HEAD
ADJUST POSITION
Trim and Other -32 -81 -87
White oversize trim ring. Specify O.D. 15° bottom pan achieves 50° high angle illumination in one direction. Maximum recessed depth 15-1/8”. Custom length (> 35 feet) plenum rated wall control cables (4 for MRR-12620; 2 for MRR-12622). Specify length.
Custom color self-flanged flare trim instead. Consult factory. -99 Special modification. Consult factory. -BI Beeper (remote control) inactivated by factory. -IP IP65 rated trim and lens. -RC Extra remote control. -RS Remote infrared sensor with 35’ cable. Ceiling mount typical. -SE Fixtures modified for seismic anchorage (by others). Meets California OSHPD and International Building Codes.
(See specification sheets for availability and details.) www.kirlinlighting.com
SECTION III: motorized exam lighting Typical Side View: MRR-12620 in NICU
Typical Side View: MRR-12620 in Patient Room 4’ [112cm]
LUMINAIRES
4’ [112cm]
CONTROL CABLE 35’ [1067cm] 23° (35° Max)
WALL CONTROL & BACK BOX
22° (35° Max)
2’ 8‘’ [81cm]
30°
SITE
8’ [244cm]
8’ [244cm] 3’ 6” [107cm]
3’ [91cm]
3’ 6” [107cm]
3’ 4” [101cm] Front View
Side View
Typical Side View: MRR-12622 in Patient Room LUMINAIRE
CONTROL CABLES 35’ [1067cm]
oG
Bi
d™ ar
OPTeCOLOR™ LEDs
WALL CONTROL & BACK BOX
Optional 15° bottom pan (Option -81) allows lighthead to be tilted up to 50° for high angle illumination or to accommodate fixture location further from the bed.
SITE
8’ [244cm]
3.5’ [107cm]
3’ [91cm]
Footcandle Distribution Data: MRR-12620 (Two Light System) 4' Spacing 8990 2150 160
8' Ceiling:
6670 2460 200
60
3' Work Plane 8990 fc 3'4" Work Plane 10000 fc
9' Ceiling:
5110 2550 240
60
3' Work Plane 3'4" Work Plane
Photometric testing by ITL (Boulder, CO) I.T.L. Test No. 83197
6670 fc 7330 fc
10' Ceiling:
60
3' Work Plane 3'4" Work Plane
5110 fc 5570 fc
Footcandle Distribution Data: MRR-12622 (One Light System) 5610
8' Ceiling:
920
70
3' Work Plane 3'4" Work Plane
www.kirlinlighting.com
3900 1150
30
5610 fc 6420 fc
9' Ceiling:
90
2870 1250 110
30
3' Work Plane 3'4" Work Plane
3900 fc 4370 fc
10' Ceiling:
30
3' Work Plane 3'4" Work Plane
2870 fc 3160 fc Page 41
SECTION III: motorized exam lighting LED Motorized High CRI / R9 Recessed Patient Low Voltage Lighting System
OPTe MED™
2014 IES Progress Report Selection
MRR-12640 (Two Light System) MRR-12642 (One Light System) FEATURES • OPTeCOLOR™ LEDs deliver up to 10,000 fc with no heat in the beam. • OPTeCOLOR™ LEDs provide 95+ CRI (with high R9, R13 and R15) for excellent color rendering of blood, red tissues and skin tones. 60,000 hour life (L70) dramatically reduces maintenance frequency and cost. • Light delivered at angles up to 35° (and 50° with Option -81) with full 360° rotation to provide coverage of the patient. • One hand operation of wall control: joystick (360°) for direction; slide dimmer for intensity (100-10%); push button for power on-off. • Independent direction control of each light. Light beams may be aimed at 2 separate sites or superimposed. • Fully recessed fixtures with BioGard™ antimicrobial trims are unobtrusive and inconspicuous, providing a safe and open space for staff and a home-like atmosphere for patients. Easily installs in T-bar or drywall ceilings with mounting hardware provided. • Smooth surfaces and minimal surface areas (both fixtures and controls) are easy to clean and disinfect. • Redundancy of electronic components and circuitry ensures at least 75% (MRR-12640) illumination at all times. • Kirlin’s exclusive three year limited warranty.
MRR-12640
MRR-12642
Applications • ICU/CCU
• ED
• NICU/PICU
• PATIENT ROOM 16-7/8” x 13” (429mm x 330mm)
11-5/8” (295mm)
35° 11-3/8” (289mm) OPTe MED™
OPTe MED™
DIMMER
DIMMER
HEAD
LEFT
HEAD
RIGHT
LEFT
FOOT
RIGHT
FOOT
5-9/16” (141mm)
8-1/8” (206mm)
Input Power: SPECIFY
Color Temperature (CCT)
-120 120V (50-60Hz) input and thermal protector. -58 277/120 volt stepdown transformer for 277 volt line input, prewired into each fixture; with 277 volt thermal protector. -97 For other input supply voltages, consult factory. -98 347/120 volt stepdown transformer for 347 volt line input, prewired into each fixture; with 120 volt thermal protector. Adds 10 watts to each fixture load.
-41K 4100°K instead of 3500°K. 95+ CRI. -50K 5000°K instead of 3500°K. 95+ CRI.
Page 42
Trim and Other -32 -81 -87
White oversize trim ring. Specify O.D. 15° bottom pan achieves 50° high angle illumination in one direction. Maximum recessed depth 15-1/8". Custom length (> 35 feet) plenum rated wall control cables (4 for MRR-12640; 2 for MRR12642). Specify length in feet.
LEFT
5-5/8” 4-1/2” 4-11/16” (143mm) (114mm) (119mm)
RIGHT
FOOT
4-11/16” (119mm)
ON • OFF
ON • OFF
Lighting Innovators Since 1895 313-259-6400 • www.kirlinlighting.com • Detroit, MI USA
Lighting Innovators Since 1895 313-259-6400 • www.kirlinlighting.com • Detroit, MI USA
Popular Options
HEAD
4-1/2” (114mm)
2-1/2” (64mm)
-94 -99 -IP -SE
5-5/8” 2-3/16” 2-1/2” (143mm) (56mm) (64mm)
Custom color self-flanged flare trim instead. Consult factory. Special modification. Consult factory. IP65 rated trim and lens. Fixtures modified for seismic anchorage (by others). Meets California OSHPD and International Building Codes. Consult factory.
(See specification sheets for availability and details.) www.kirlinlighting.com
2-3/16” (56mm)
SECTION III: motorized exam lighting Typical Side View: MRR-12640 in Patient Room 4’ [112cm]
LUMINAIRES
Typical Side View: MRR-12640 in NICU 4’ [112cm]
CONTROL CABLE 35’ [1067cm]
2’ 8‘’ [81cm]
23° (35° Max)
WALL CONTROL & BACK BOX
22° (35° Max)
OPTe MED™
30°
SITE
8’ [244cm]
8’ [244cm] 3’ 6” [107cm]
3’ [91cm]
3’ 6” [107cm]
3’ 4” [101cm] Front View
Side View
Typical Side View: MRR-12642 in Patient Room LUMINAIRE
CONTROL CABLES 35’ [1067cm]
oG
Bi
d™ ar
OPTeCOLOR™ LEDs
WALL CONTROL & BACK BOX
Optional 15° bottom pan (Option -81) allows lighthead to be tilted up to 50° for high angle illumination or to accommodate fixture location further from the bed.
SITE
8’ [244cm]
3.5’ [107cm]
3’ [91cm]
Footcandle Distribution Data: MRR-12640 (Two Light System) 4' Spacing 8990 2150 160
8' Ceiling:
6670 2460 200
60
3' Work Plane 8990 fc 3'4" Work Plane 10000 fc
5110 2550 240
60
3' Work Plane 3'4" Work Plane
9' Ceiling:
Photometric testing by I.T.L. (Boulder, CO) I.T.L. Test No. 83197
6670 fc 7330 fc
60
3' Work Plane 3'4" Work Plane
10' Ceiling:
5110 fc 5570 fc
Footcandle Distribution Data: MRR-12642 (One Light System) 5610
8' Ceiling:
920
70
3' Work Plane 3'4" Work Plane
www.kirlinlighting.com
3900 1150
30
5610 fc 6420 fc
9' Ceiling:
90
2870 1250 110
30
3' Work Plane 3'4" Work Plane
3900 fc 4370 fc
10' Ceiling:
30
3' Work Plane 3'4" Work Plane
2870 fc 3160 fc Page 43
SECTION IV: shower lights
(recessed Deadfront)
A SAFER ENVIRONMENT • Dead-front electrically non-conductive trims standard. • Higher light levels provided, ensuring effective patient bathing and shower cleaning/maintenance. • Impact resistant lenses and reinforced trims provide safety for patient and staff. • Fully gasketed trims reduce moisture intrusion into recessed housing.
DESIGNED SPECIFICALLY FOR THE DEMANDS OF SHOWERS
• Fully gasketed trims. Wet, damp or dry locations (covered ceilings) listing. • Corrosion resistant all-aluminum construction results in components operating 25% cooler, extending every component life by 50%. • KIRLIN exclusive acrylic enamel finish protects aluminum from corrosion and exceeds ASTM 1000 hour salt spray test. • LEDs produce up to 80% less heat than traditional light sources, significantly reducing the load on hospital HVAC systems. • Shallow and super shallow housings for easier installation in crowded plenums.
IP65
IP65 trims protect against pathogens passing through the trim, either into the plenum or into the room environment.
DEPENDABILITY and REDUCED OPERATING COSTS • Long LED life, up to 90,000 hours (L70), results in 90 fewer lamp changes over the life of the system. • Power consumption is reduced by up to 80% over traditional light sources • Fully sustainable. Modular internal components are visible and easily accessed through the aperture of the fixture. Simple lighthead / trim component change available to modify spacing criteria, if desired, anytime. Replacement components are available years into the future.
ARRA
QUALIFIED
Exclusive Five Year Warranty • Designed and Produced in U.S.A. • UL, C-UL (Canada) Listed Page 44
www.kirlinlighting.com
Section IV: shower Lights (recessed Deadfront) Design
Flare
Flare
Flare
IP65
Flare
Flare
Regressed Lens
Regressed Lens
Regressed Lens
Tamper Resistant
Super Shallow
Super Shallow
Drop Polycarbonate Trim
Drop Polycarbonate Trim
Function
Downlight
Downlight
Downlight
Downlight
Downlight
Downlight
Downlight
Downlight
Aperture (Inches)
Product #
4
6
6
7
4
5
5
5
Performance Lumens
Watts
MRR-04700-2500L
2500
35
MRR-06705-1500L
1500
15
MRR-06705-1000L
1000
11
MRR-06705-500L
500
5
MRR-06710-2500L
2500
35
MRV-07715-1500L
1500
15
MRV-07715-1000L
1000
11
MRV-07715-500L
500
5
MRR-04720-1500L
1500
15
MRR-04720-1000L
1000
11
MRR-04720-500L
500
5
MRR-05725-2500L
2500
35
MRR-05730-1500L
1500
15
MRR-05730-1000L
1000
11
MRR-05730-500L
500
5
MRR-05735-2500L
2500
35
OPTIONS / luminaire ordering
Page
46
46
46
47
47
PLEASE VISIT www.kirlinlighting.com FOR KIRLIN COMPACT FLUORESCENT AND INCANDESCENT SHOWER LIGHTS IN KIRLIN’S PATIENT EXAM & HEALTHCARE LIGHTING CATALOG (BULLETIN 08HC).
ALL KIRLIN SHOWER LIGHTS ARE U.L. LISTED WET LOCATIONS
www.kirlinlighting.com
Page 45
Section IV: shower Lights
FLARE REGRESSED LENS PERFORMANCE (-2500L Series)
4”
2800 LUMENS 35W MFL (std) SC: 0.8
MRR-04700-2500L
LPW: 77
75˚
1250
60˚
2500 3750 0˚
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
107.0 60.5 38.7 26.9 19.7 15.1
5.0 6.6 8.3 9.9 11.6 13.2
-NFL
Lm: 2390 SC: 0.5
PERFORMANCE (-1500L Series)
6”
1721 Lumens 20W
MRR-06705-1500L MRR-06705-1000L MRR-06705-500L
90˚
MFL (std) SC: 0.8 IC
LPW: 83
90˚ 75˚
800
60˚
1600 2400 0˚
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
67.3 37.8 24.2 16.8 12.4 9.5
4.9 6.6 8.2 9.9 11.5 13.2
-SPT
-NFL
-WFL
Lm: 1744 SC: 0.3
Lm: 1553 SC: 0.6
Lm: 1514 SC: 1.1
-NFL
-WFL
Lm: 2888 SC: 0.5
Lm: 2379 SC: 1.0
-SPT
-NFL
-WFL
Lm: 1581 SC: 0.3
Lm: 1468 SC: 0.6
Lm: 1321 SC: 1.0
PERFORMANCE (-2500L Series)
6”
2993 LUMENS 35W MFL (std) SC: 0.8
MRR-06710-2500L
LPW: 81
90˚ 75˚
1250
60˚
2500 3750 0˚
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
109.0 61.6 39.4 27.4 20.1 15.4
5.0 6.7 8.4 10.0 11.7 13.4
IP65 & Tamper resistant REGRESSED LENS PERFORMANCE (-1500L Series)
7”
1495 LUMENS 20W
MRV-07715-1500L MRV-07715-1000L MRV-07715-500L
MFL (std) SC: 0.8 IC
LPW: 72
90˚ 75˚
650
60˚
1300 1950 0˚
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
50.7 28.5 18.2 12.7 9.3 7.1
5.1 6.8 8.5 10.2 11.9 13.6
SUPER SHALLOW FLARE REGRESSED LENS MAXIMUM PERFORMANCE (-1500L Series)
4”
1685 LUMENS 20W
MRR-04720-1500L MRR-04720-1000L MRR-04720-500L
6”
MFL (std) SC: 0.7 IC
LPW: 80
60˚
1800 2700 0˚
45˚ 15˚
2753 LUMENS
MFL SC: 0.7 LPW: 75 Page 46
75˚
900
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
76.6 43.1 27.6 19.2 14.1 10.8
4.1 5.5 6.8 8.2 9.6 11.0
-NFL
-WFL
Lm: 1800 SC: 0.4
Lm: 1363 SC: 0.8
PERFORMANCE (-2500L Series)
35W
MRR-05725-2500L
90˚
90˚ 75˚
1500
60˚
3000 4500 0˚
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
126.1 70.9 45.4 31.5 23.2 17.7
4.1 5.4 6.8 8.1 9.5 10.8
www.kirlinlighting.com
Section IV: shower Lights
Drop Polycarbonate Trim
5”
MAXIMUM PERFORMANCE (-1500L Series) 1078 LUMENS 20W MFL SC: 0.7
MRR-05730-1500L MRR-05730-1000L MRR-05730-500L
LPW: 52
IC
90˚ 75˚
225
60˚
450 675 0˚
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
17.9 10.1 6.5 4.5 3.3 2.5
4.5 5.9 7.4 8.9 10.4 11.9
PERFORMANCE (-2500L Series)
5” 1878 LUMENS 35W WFL SC: 0.9 LPW: 54
MRR-05735-2500L
90˚ 75˚
300
60˚
600 900 0˚
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
24.9 14.0 9.2 6.2 4.6 3.5
5.4 7.2 8.9 10.7 12.5 14.3
▲ Cone of Light Key
Ft. Distance from fixture FC Footcandles at nadir (0°) Dia. Circle of light at 50% of FC Dia. (in ft.) shown is where FC value is half the FC at nadir.
Popular Options Input Power: SPECIFY -120 120V (50-60Hz) input and thermal protector. -277 277V (50-60Hz) input and thermal protector. -97 Specify other voltage. Consult factory.
-HC 90+ CRI instead. 2700° or 3000°K only. Reduces output by ~15%.
Optics
LED Power Supply
-NFL Narrow flood distribution instead. -WFL Wide flood distribution instead.
-EI
Lenses and Trims
REMOTE emergency inverter. 85% of rated lumens for -2500L or 100% for -1500L and lower. Run time: 90+ minutes. 120 or 277V, 60Hz input only. Specify voltage.
Color (CCT and CRI)
-13
-21 -23 -32
-27K Color temperature 2700°K instead. -30K Color temperature 3000°K instead. -41K Color temperature 4100°K instead.
-94 Custom color/finish. Specify. Consult factory. -CF Custom color filter (Rosco). Specify. -WA White acrylic (flat) diffuser instead.
Other -79 -99 -FS
Vandal resistant dual lens system: prismatic high strength acrylic above, clear poly below, plus tamperproof hardware, instead of standard lens and hardware. White translucent flat poly diffuser instead. Frosted tempered microprismatic lens instead. White oversize trim ring. Specify O.D.
Extension collar for ceilings up to 2-5/8 ” thick. Special modification. Consult factory. In-line fusing.
(See specification sheets for availability and details.)
Luminaire Ordering EXAMPLE MUST SPECIFY
OPTIONAL
Product Number
Voltage
Options
MRR-06705-1500L MRR-06705-1000L MRR-06705-500L
-120 (120 volts) -277 (277 volts) -97 (Specify other)
See “Options” above
Ordering Example: MRR-06705-1500L-120-21-WFL
LUMEN SERIES AVAILABLE Lumen Series Code
Nominal Lumens
-2500L
2500 Lumens
-1500L
1500 Lumens
-1000L
1000 Lumens
-500L
500 Lumens
www.kirlinlighting.com
Page 47
Section V: general LIGHTING: PUBLIC & clinical spaceS KIRLIN quality & value throughout Inconspicuous downlights with matching wall washes in round and square designs are available in four distributions from spot (-SPT) to wide flood (-WFL) and many color temperatures. Super Shallow downlights offer uniform illumination scaled down to fit in healthcare facilities’ crowded plenums. IP65 rated sealed trims and ISO 5 Class 100 rated sealed fixtures provide protection against infection while maintaining a sophisticated architectural aesthetic from various apertures with matching LookALike™ regressed lens trims. oG
IP65 sealed trim, BioGard™ antimicrobial finish
Bi
Level 2 + Protection
oG
Bi
IP65 sealed trim, vandal resistant, BioGard™ antimicrobial finish
Level 3 Protection
ISO 5/class 100 sealed “cleanroom” fixture, BioGard™ antimicrobial finish
IP65
d™ ar
oG
Bi
d™ ar
d™ ar
IP65
VR
IP65
ISO 5 CLASS
Level 2 Protection
100
CLEANROOM
Section V: general LIGHTING: PUBLIC & CLINICAL SPACES Function
Application
Aperture (Inches)
Product #
Performance Lumens
Watts
MRR-04800-1500L
1500
15
MRR-04800-1000L
1000
11
MRR-04800-500L
500
5
MRR-04802-1500L
1500
15
MRR-04802-1000L
1000
11
MRR-04802-500L
500
5
MRS-04803-1500L
1500
15
MRS-04803-1000L
1000
11
MRS-04803-500L
500
5
MRS-04804-1500L
1500
15
MRS-04804-1000L
1000
11
MRS-04804-500L
500
5
MRR-06805-5000L
5000
55
MRR-06805-3500L
3500
42
MRR-06805-2500L
2500
35
Page
DOWNLIGHTING and wall washing: round and square Downlight Open Appearance
Wall Wash Open Appearance
Downlight Open Appearance
Wall Wash Open Appearance
Downlight Open Appearance
Page 48
Nurse Station Admissions
Lobby Cafeteria
Conference Room Waiting Room
Corridor Auditorium
Conference Room Lobby
4
4
4
4
6
50
www.kirlinlighting.com
Section V: general LIGHTING: PUBLIC & CLINICAL SPACES Function
Application
Aperture (Inches)
Product #
Performance Lumens
Watts
MRR-06810-5000L
5000
55
MRR-06810-3500L
3500
42
MRR-06810-2500L
2500
35
MRR-06815-5000L
5000
55
MRR-06815-3500L
3500
42
MRR-06815-2500L
2500
35
MRR-04820-1500L
1500
15
MRR-04820-1000L
1000
11
MRR-04820-500L
500
5
MRR-05825-2500L
2500
35
MRR-07830-1500L
1500
15
MRR-08835-5000L
5000
55
MRR-08835-3500L
3500
42
MRR-08835-2500L
2500
35
MRV-07840-1500L
1500
15
MRV-08845-5000L
5000
55
MRV-08845-3500L
3500
42
MRV-08845-2500L
2500
35
Page
DOWNLIGHTING and wall washing Wall Wash Open Appearance
Downlight Regressed Lens
Downlight Super Shallow
Downlight Super Shallow
Hallway Registration
Dining Room Auditorium
Canopy Nurse Station
Entrance Kitchen
6
6
4
5
50
51
LEVEL 2 protection: IP65 sealed trim, BioGard™ antimicrobial finish Downlight IP65 BioGard™ Downlight IP65 BioGard™
Soffit Locker Room
Wet Location Canopy
7
8
51
LEVEL 2+ protection: IP65 sealed trim, vandal resistant, BioGard™ antimicrobial finish Downlight IP65 Tamper Resistant BioGard™ Downlight IP65 Tamper Resistant BioGard™
Psychiatric ED
Psychiatric Trauma
7
8
52
LEVEL 3 protection: ISO 5/class 100 sealed “cleanroom” fixture, BioGard™ antimicrobial finish Downlight ISO 5/Class 100 Cleanroom BioGard™ Downlight ISO 5/Class 100 Cleanroom BioGard™
Operating Room ICU / NICU / PICU
Hybrid OR Operating Room
7
8
MRR-07850-1500L
1500
15
MRR-08855-5000L
5000
55
MRR-08855-3500L
3500
42
MRR-08855-2500L
2500
35
Popular Options and Luminaire Ordering Scenic Panel: 2’ x 2’ Building Block Configuration
53
24
MRP-22295
SCENIC PANEL IMAGES, CONFIGURATIONS, product specification guide and Options www.kirlinlighting.com
52
20
54
55-57 Page 49
Section V: general LIGHTING: PUBLIC & clinical spaceS PERFORMANCE (-1500L Series)
Downlight
4” 1538 LUMENS 20W MFL (std)
MRR-04800-1500L MRR-04800-1000L MRR-04800-500L
SC: 0.8 IC
LPW: 74
90˚
2400 0˚
Square Downlight
MRR-04802-1500L MRR-04802-1000L MRR-04802-500L
Square Wall Wash
Wall Wash
45˚ 15˚
30˚
Dist.
FC
Dia.
6 8 10 12 14 16
64.9 36.5 23.4 16.2 11.9 9.1
4.9 6.6 8.2 9.9 11.5 13.2
-SPT
-NFL
Lm: 1629 SC: 0.3
Lm: 1428 SC: 0.6
PERFORMANCE (-1500L Series) 90˚
4”
4”
1375 Lumens
550
20W
1100
LPW: 66 IC
1650 0˚
75˚ 60˚ 45˚ 15˚
30˚
MAXIMUM PERFORMANCE (-1500L Series) 1579 LUMENS 20W MFL (std)
MRS-04803-1500L MRS-04803-1000L MRS-04803-500L
SC: 0.8 IC
LPW: 75
90˚ 75˚
850
60˚
1700 2550 0˚
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
72.6 40.8 26.1 18.1 13.3 10.2
4.6 6.1 7.7 9.2 10.7 12.3
-SPT
-NFL
Lm: 1704 SC: 0.3
Lm: 1434 SC: 0.6
MAXIMUM PERFORMANCE (-1500L Series) 90˚
MRS-04804-1500L MRS-04804-1000L MRS-04804-500L
1385 Lumens
500
20W
1000
LPW: 66 IC
1500 0˚
75˚ 60˚ 45˚ 15˚
30˚
MAXIMUM PERFORMANCE (-5000L Series)
6”
Downlight
60˚
1600
4”
4746 LUMENS 55W MFL (std)
MRR-06805-5000L MRR-06805-3500L MRR-06805-2500L
SC: 0.8 LPW: 82
90˚ 75˚
2200
60˚
4400 6600 0˚
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
175.1 98.5 63.1 43.8 32.2 24.6
5.2 6.9 8.6 10.3 12.0 13.7
-SPT
-NFL
-WFL
Lm: 4893 SC: 0.3
Lm: 4892 SC: 0.5
Lm: 4009 SC: 0.9
MAXIMUM PERFORMANCE (-5000L Series)
6”
Wall Wash
75˚
800
Cone of Light ▲
90˚
MRR-06810-5000L MRR-06810-3500L MRR-06810-2500L
Page 50
4141 Lumens
1500
55W
3000
LPW: 72
4500 0˚
75˚ 60˚ 45˚ 15˚
▲ Cone of Light Key
Ft. Distance from fixture FC Footcandles at nadir (0°) Dia. Circle of light at 50% of FC Dia. (in ft.) shown is where FC value is half the FC at nadir.
30˚
www.kirlinlighting.com
Section V: general LIGHTING: PUBLIC & clinical spaceS MAXIMUM PERFORMANCE (-5000L Series)
Downlight
6” 4897 LUMENS 55W MFL (std)
MRR-06815-5000L MRR-06815-3500L MRR-06815-2500L
SC: 0.8 LPW: 82
90˚ 75˚
2500
60˚
5000 7500 0˚
45˚ 15˚
30˚
1685 LUMENS
Super Shallow Downlights
20W MFL (std) SC: 0.7 FLARE TRIM
IC
LPW: 80
90˚ 75˚
900
60˚
1800 2700 0˚
FC
Dia.
6 8 10 12 14 16
182.0 102.0 65.5 45.5 33.4 25.6
5.0 6.6 8.3 9.9 11.6 13.3
-WFL
Lm: 4989 SC: 0.6
Lm: 4161 SC: 1.1
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
76.6 43.1 27.6 19.2 14.1 10.8
4.1 5.5 6.8 8.2 9.6 11.0
-NFL
-WFL
Lm: 1800 SC: 0.4
Lm: 1363 SC: 0.8
PERFORMANCE (-2500L Series)
5” 2409 LUMENS 35W WFL SC: 1.2
MRR-05825-2500L
Dist.
-NFL
MAXIMUM PERFORMANCE (-1500L Series)
4”
MRR-04820-1500L MRR-04820-1000L MRR-04820-500L
Cone of Light ▲
FLAT TRIM
LPW: 66
90˚ 75˚
350
60˚
700 1050 0˚
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
31.6 17.8 11.4 7.9 5.8 4.5
6.9 9.3 11.3 13.9 16.2 18.5
▲ Cone of Light Key
Ft. Distance from fixture FC Footcandles at nadir (0°) Dia. Circle of light at 50% of FC Dia. (in ft.) shown is where FC value is half the FC at nadir.
Level 2 Protection
oG
Bi
IP65 sealed trim, BioGard™ antimicrobial finish
7”
20W
IP65 Downlights
MFL (std) SC: 0.8 IC
LPW: 83
8”
90˚ 75˚
800
60˚
1600 2400 0˚
45˚ 15˚
55W MFL (std)
www.kirlinlighting.com
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
67.3 37.8 24.2 16.8 12.4 9.5
4.9 6.6 8.2 9.9 11.5 13.2
-SPT
-NFL
-WFL
Lm: 1744 SC: 0.3
Lm: 1553 SC: 0.6
Lm: 1514 SC: 1.1
MAXIMUM PERFORMANCE (-5000L Series) 5310 LUMENS
MRR-08835-5000L MRR-08835-3500L MRR-08835-2500L
IP65
PERFORMANCE (-1500L Series) 1721 Lumens
MRR-07830-1500L
d™ ar
SC: 0.8 LPW: 94
90˚ 75˚
2500
60˚
5000 7500 0˚
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
188.0 106.0 67.8 47.1 34.6 26.5
5.1 6.7 8.4 10.1 11.8 13.5
-NFL
-WFL
Lm: 5298 SC: 0.5
Lm: 4416 SC: 1.1
Page 51
Section V: general LIGHTING: PUBLIC & clinical spaceS Level 2 + Protection
oG
Bi
IP65 sealed TRIM, VANDAL RESISTANT, BioGard™ antimicrobial finish
7”
MFL (std) SC: 0.8 LPW: 72
90˚ 75˚
650
60˚
1300 1950 0˚
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
50.7 28.5 18.2 12.7 9.3 7.1
5.1 6.8 8.5 10.2 11.9 13.6
-SPT
-NFL
-WFL
Lm: 1581 SC: 0.3
Lm: 1468 SC: 0.6
Lm: 1321 SC: 1.0
IC
8” MAXIMUM PERFORMANCE (-5000L Series) 4857 LUMENS 55W MFL (std)
MRV-08845-5000L MRV-08845-3500L MRV-08845-2500L
LPW: 81
90˚ 75˚
1800
60˚
3600 5400 0˚
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
147.0 82.5 52.8 36.7 26.9 20.6
5.1 6.8 8.5 10.2 11.9 13.6
Level 3 Protection
Lm: 4749 SC: 0.5
Lm: 4432 SC: 1.1
oG
d™ ar
IP65
ISO 5
100
CLEANROOM
PERFORMANCE (-1500L Series) 1721 Lumens 20W MFL (std) SC: 0.8 LPW: 83
MRR-07850-1500L
-WFL
Bi
ISO 5/class 100 sealed “cleanroom” fixture, BioGard™ antimicrobial finish
7”
-NFL
CLASS
IP65 and Tamper Resistant Downlights
20W
SC: 0.8
Cleanroom Rated Downlights
VR
PERFORMANCE (-1500L Series) 1495 LUMENS
MRV-07840-1500L
IP65
d™ ar
90˚ 75˚
800
60˚
1600 2400 0˚
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
67.3 37.8 24.2 16.8 12.4 9.5
4.9 6.6 8.2 9.9 11.5 13.2
-SPT
-NFL
Lm: 1744 SC: 0.3
Lm: 1553 SC: 0.6
IC
8” MAXIMUM PERFORMANCE (-5000L Series) 5310 LUMENS 55W MFL (std) SC: 0.8
MRR-08855-5000L MRR-08855-3500L MRR-08855-2500L
Page 52
LPW: 94
90˚ 75˚
2500
60˚
5000 7500 0˚
45˚ 15˚
30˚
Cone of Light ▲ Dist.
FC
Dia.
6 8 10 12 14 16
188.0 106.0 67.8 47.1 34.6 26.5
5.1 6.7 8.4 10.1 11.8 13.5
-NFL
-WFL
Lm: 5298 SC: 0.5
Lm: 4416 SC: 1.1
2013 IES Progress Report Selection
www.kirlinlighting.com
Section V: general LIGHTING Input Power
separately. Order LPS-1220A (0-10V analog with 100-0.2% PWM dimming). Available for -1500L, -2500L and -5000L lumen series luminaires only. See below and LPS-1220A specification sheet and Owner’s Manual at www.kirlinlighting.com.
-120 120V (50-60Hz) input and thermal protector. -277 277V (50-60Hz) input and thermal protector. -97 Specify other voltage. Consult factory.
LED Power Supply -29 Two wire full range (100-1%) PWM dimming instead (Lutron). 120V only. Not available with -EI. -39 Three wire full range (100-1%) PWM dimming instead (Lutron). -EI REMOTE emergency inverter for 45% of rated lumens for -5000L, 55% for -3500L, 85% for -2500L or 100% for -1500L and lower. Run time: 90+ minutes. 120 or 277V, 60 Hz input only. Specify voltage. Not for use with -SS SmartSupply™ driver or with Option -29. -EM INTERNAL emergency battery pack. Delivers 500 lumens. Run time: 90+ minutes. -EMH INTERNAL emergency battery pack. Delivers 1000 lumens. Run time: 90+ minutes. Marked spacings installation may be required; refer to individual specification sheet. -ER REMOTE emergency battery pack. Delivers 500 lumens. Run time: 90+ minutes. -ERH REMOTE emergency battery pack. Delivers 1000 lumens. Run time: 90+ minutes. -SS Remote mounted Kirlin SmartSupply™ driver (instead of standard internal driver), sold
popular options
Color (CCT and CRI) -27K -30K -41K -HC
Color temperature 2700°K instead. Color temperature 3000°K instead. Color temperature 4100°K instead. 90+ CRI instead. 2700° or 3000°K only. Reduces output by ~15%.
-NFL Narrow flood distribution. (0.5 SC) -SPT Spot distribution. (0.4 SC) -WFL Wide flood distribution. (1.0 SC)
Custom color filter (Rosco). Specify. Green acrylic filter mounted in lens assembly. Custom filter mounted in lens assembly. Specify.
Other
Lenses and Trims
-17 -21 -23 -30 -31
Filter -CF -GE -XF
Optics (-MFL Standard)
-13
-32 White oversize trim ring. Specify O.D. -35T Natural aluminum acrylic (silver) enameled trim. -45 Gasket between trim flange and ceiling. -46 Gasket between trim and lens. -70 SofTex Clear self-flanged cone. (CP x .93) -94 Custom color/finish. Specify. Consult factory. -BG Antimicrobial Kirlin BioGard™ white (only) trim finish. -DF Electrically isolated “dead front” gasketed trim. -WA White acrylic (flat) diffuser instead.
Vandal resistant dual lens system: prismatic high strength acrylic above, clear poly below with tamperproof hardware, instead of standard lens and hardware. Prismatic high strength acrylic lens instead. White translucent flat poly diffuser instead. Frosted tempered microprismatic lens instead. All white acrylic enameled cone. White acrylic enameled flange (only).
-79 -99 -FD -FS
Extension collar for ceilings up to 2” thick. Special modification. Consult factory. Dual circuit fusing. For use only with Option -EI and either -5000L or -3500L lumen series. In-line fusing. Not for use with Option -EI and either -5000L or -3500L lumen series: See -FD instead.
(See specification sheets for availability and details.)
SmartSupply™ REMOTE DIMMING DRIVER - OPTIONAL • Full range 100% to 0.2% dimming and 3 dimming zones. • Drives up to (12) -1500L, (6) -2500L or (3) -5000L luminaires. • Over wattage, cross channel, and electrical fast transient (EFT) protection. • Input: 115-277VAC / 50-60Hz rated. Dedicated 120VAC input recommended. For 277VAC input, proper line filtering and surge protection must be provided (by others). Maximum continuous input voltage is 290VAC. • Requires 16 AWG (minimum) twisted pair shielded wire from SmartSupply™ to luminaires. • FIVE YEAR Limited Warranty.
LPS-1220A
See LPS-1220A Owner’s Manual for more information including compatible controls and wiring diagrams.
Luminaire Ordering EXAMPLE MUST SPECIFY
OPTIONAL
Product Number
Voltage
Options
MRR-06805-5000L MRR-06805-3500L MRR-06805-2500L
-120 (120 volts) -277 (277 volts) -97 (Specify other)
See “Options” above
Ordering Example: MRR-06805-5000L-120-30K-NFL
LUMEN SERIES AVAILABLE Lumen Series Code
Nominal Lumens
Lumen Series Code
Nominal Lumens
-5000L
5000 Lumens
-1500L
1500 Lumens
-3500L
3500 Lumens
-1000L
1000 Lumens
-2500L
2500 Lumens
-500L
500 Lumens
www.kirlinlighting.com
Page 53
Scenic Panel system: MRP-22295 SERIES* • Selection of beautiful smooth panel artwork attractively and uniformly illuminated • Wave guide lens provides superior uniform illumination • Regressed trim provides architectural “skylight” effect • Ultra-shallow (2”) recessed aluminum housing
• • • •
IC
Lays into 2’ x 2’ grid ceiling 100-10% dimming 60,000 hours (L70) life Also compatible with SmartSupply™ LPS-0700A. See page 57.
MRP-22295*
Regressed bevel provides architectural “skylight” effect.
2’ x 2’ Scenic Panels create a soothing and attractive luminous ceiling.
Ultra-shallow (2”) aluminum housing requires minimal plenum space.
*Not for use in MRI applications. See Section I: MRI Lighting Systems MRP-22290 for MRI compatible Scenic Panel systems.
Page 54
www.kirlinlighting.com
Scenic Panel system: Images Artwork Select artwork by adding the option code (i.e., -A01) of the respective artwork. For custom artwork, use Option -A99.
-A01
-A02
-A03
Custom Artwork (Customer supplied*)
-A05
-A06
-A04
Custom Artwork Preferred Image Resolution 1800 x 1800 pixels (or greater) per 24” x 24” panel. See “Overall Size and Orientation” table on page 56 for preferred image resolution for each configuration.
-A99
* For custom artwork, customer is responsible for supplying the artwork and obtaining the appropriate usage rights.
Dividing and Cropping Artwork When specifying size, orientation and artwork, consider how the image will be divided and cropped. For example:
-4x4
-6x4
-4x6
To see how your artwork will divided and cropped, consult factory. www.kirlinlighting.com
Page 55
Scenic Panel system: Panel Configurations 1. 2. 3. 4.
Use MRP-22295* as base catalog number, then add configurations and selections as follows. Choose overall size and orientation of the display using the “Overall Size and Orientation” table below. Select artwork with option codes (i.e., -A01). Consider how the artwork will be displayed. See “Dividing and Cropping Artwork”. For SmartSupply™ LPS-0700A remote driver instead, use Option -SS and order the appropriate number of LPS-0700A remote drivers separately. See page 57 for more information. 5. Following the submission of your order, and before production, you will receive a proof for your review and approval.
Overall Size and Orientation Landscape
Portrait
Option
Preferred Resolution (Pixels)
1
-2x2
1800 x 1800
2’ x 4’
2
-4x2
3600 x 1800
4’ x 4’
4
-4x4
3600 x 3600
4’ x 6’
6
-6x4
5400 x 3600
6’ x 6’
9
-6x6
5400 x 5400
6’ x 8’
12
-8x6
7200 x 5400
8’ x 8’
16
-8x8
7200 x 7200
Nominal Dimensions
Fixture Qty
2’ x 2’
Custom Size
Arrangement
Arrangement
Option
Preferred Resolution (Pixels)
-2x4
1800 x 3600
-4x6
3600 x 5400
-6x8
5400 x 7200
-9x9 Specify number of panels and orientation of artwork.
*Not for use in MRI applications. See Section I: MRI Lighting Systems MRP-22290 for MRI compatible Scenic Panel systems.
Page 56
www.kirlinlighting.com
SCENIC PANEL product SPECIFICATION EXAMPLE MRP-22295 -120 -4x6 -A01
Example: Scenic Panel Product Number
Specify Voltage
Artwork Option
Size and Orientation Option*
*-4x6 is not the same as -6x4, see page 56.
POPULAR SCENIC PANEL Options Input Power: SPECIFY
LED Power Supply
-120 120V (50-60Hz) input and thermal protector. -277 277V (50-60Hz) input and thermal protector. -97 Specify other voltage. Consult factory.
-29 Two wire full range (100-1%) PWM dimming instead (Lutron). 120V only. -39 Three wire full range (100-1%) PWM dimming instead (Lutron).
-SS
Remote mounted Kirlin SmartSupply™ driver (instead of standard internal driver), sold separately. Order LPS-0700A (0-10V analog with 100-0.2% PWM dimming). See below and refer to LPS-0700A specification sheet and Owner’s Manual at www.kirlinlighting. com.
SCENIC PANEL: SmartSupply™ DRIVER - OPTIONAL • Full range 100% to 0.2% dimming and 3 dimming zones. See page 26 or consult factory for compatible controls. • Over wattage, cross channel, and electrical fast transient (EFT) protection. • Input: 115-277VAC / 50-60Hz rated. Dedicated 120VAC input recommended. For 277VAC input, proper line filtering and surge protection must be provided (by others). Maximum continuous input voltage is 290VAC. • Requires 16 AWG (minimum) twisted pair shielded wire from SmartSupply™ to luminaires. • FIVE YEAR Limited Warranty.
LPS-0700A
With Scenic Panels (20W) (12) Channels (Circuits) Maximum Distance Per Channel
www.kirlinlighting.com
(1) scenic panel / channel Up to (12) scenic panels / SmartSupply™ 150 feet
Page 57
Section vi: NightLights / ChartLights & StepLights
TYPE IC
IC Type IC standard on all models.
Full spectrum of optional colors, including Red/Amber (Option -RA) to maintain melatonin levels and circadian rhythm.
The most comprehensive collection of NightLights, ChartLights, StepLights and options available.
Fastener-free faceplate (Option -FF) available on most models.
Double faced (thru-the-wall) NightLight illuminates two adjoining spaces. Adjustable to fit various wall thicknesses. Lenses optional instead of louvers. Applications: Patient Room / Patient Room Corridor / Patient Room Bathroom / Patient Room
Page 58
Maximum security NightLight. Optional tamper resistant designs (Option -26) available on most other models. Applications: Public spaces and psychiatric wards.
www.kirlinlighting.com
Section vi: NightLights / ChartLights & StepLights Design
Function
TYPE IC
Aperture
Product #
Watts
Page
NightLights / ChartLights - Type ic Round
Lensed
NightLight/ ChartLight
5
MNR-05900
6
Square
Lensed
NightLight/ ChartLight
5x5
MNS-05904
6 60
Rectangle Lensed
NightLight/ ChartLight
3x5
MNT-03906
5
Bricklight
Louvered
NightLight/ ChartLight
3x8
MNT-03908
6
Single Face
Louvered
NightLight
7 x 10
MNT-07912
6
NightLights - Type ic
61
Double Face
Louvered
NightLight
7 x 10
MNT-07914
12
Maximum Security Louvered
NightLight
7x9
MNV-07916
6
Round
Lensed
StepLight
5
MNR-05920
6
Square
Lensed
StepLight
5x5
MNS-05924
6
61
StepLights - type ic
62
Rectangle Lensed
StepLight
3x5
MNT-03926
5
Bricklight
StepLight
3x8
MNT-03928
6
Louvered
Popular Options and Luminaire Ordering
63
Exclusive Five Year Warranty • Designed and Produced in U.S.A. • UL, C-UL (Canada) Listed
www.kirlinlighting.com
Page 59
Section VI: NightLights / ChartLights
IC
5”
Popular Trim Options
Option Code
Fastener Free Face
-FF
Tamper Resistant Fasteners
-26
Popular Trim Options
Option Code
Fastener Free Face
-FF
Tamper Resistant Fasteners
-26
Popular Trim Options
Option Code
Tamper Resistant Fasteners
-26
Popular Trim Options
Option Code
Tamper Resistant Fasteners
-26
MNR-05900
5” x 5”
Lensed
MNS-05904
3” x 5”
MNT-03906
3” x 8”
Louvered
MNT-03908
Page 60
www.kirlinlighting.com
Section VI: NightLights 7” x 10”
Single Face Louvered
IC
Popular Trim Options
Option Code
Prismatic Lens Instead
-17
Tamper Resistant Fasteners
-26
On-Off Switch
-34
GFCI Outlet
-GF
Popular Trim Options
Option Code
Tamper Resistant Fasteners
-26
Prismatic Lens on One Side Louver on Other Side
-L1
Prismatic Lens on Both Sides
-L2
On-Off Switch on One Side
-S1
On-Off Switch on Both Sides
-S2
GFCI Outlet on One Side
-G1
GFCI Outlet on Both Sides
-G2
MNT-07912
7” x 10”
Double Face Louvered
MNT-07914
NightLights - Maximum security 7” x 9”
Single Face Louvered
IC
Popular Trim Options
Option Code
Dual Lens - Polycarbonate Lens Plus High Strength Acrylic Prismatic Lens Instead
-17
MNV-07916
www.kirlinlighting.com
Page 61
Section VI: StepLights
IC
5”
Popular Trim Options
Option Code
Fastener Free Face
-FF
Tamper Resistant Fasteners
-26
Popular Trim Options
Option Code
Fastener Free Face
-FF
Tamper Resistant Fasteners
-26
Popular Trim Options
Option Code
Tamper Resistant Fasteners
-26
Popular Trim Options
Option Code
Tamper Resistant Fasteners
-26
MNR-05920
5” x 5”
Lensed
MNS-05924
3” x 5”
MNT-03926
3” x 8”
MNT-03928
Page 62
www.kirlinlighting.com
Section VI: NightLight / ChartLight & StepLight Options Input Power: SPECIFY
-26
-120 120V (50-60Hz) input. (Required for Options -34, -GF or -HD) -277 277V (50-60Hz) input. -97 Other voltage input. Consult factory.
-34
LED Power Supply
-G1
-EI
Remote emergency inverter for 100% of rated lumens. Run time: 90+ minutes. 120 or 277V, 60 Hz input only. Specify voltage. -HW Higher light output. Approximately doubles light output.
-G2 -GF
Filter Colors -BL -GE -OR -RA -YE -CF
Blue filter. Green filter. Orange filter. Red/Amber filter. Yellow filter. Custom color filter (Rosco). Specify.
-H1 -H2 -HD
Lenses and Trims -17
.187” high strength prismatic acrylic lens with door instead of louvers. For MNV-07916 .25” clear polycarbonate with .187” high strength acrylic prismatic lensed faceplate instead.
-L1
-L2 .187” high strength acrylic prismatic lens and door instead on both sides. -S1 With hospital grade push button on-off switch installed on one side. Controls both lamps. Indoor use. Rated 120V only. Must add Option -120. -S2 With one hospital grade push button on-off switch installed on each side. Controls each side separately. Use with -84. Indoor use. Rated 120V only. Must add Option -120.
Faceplate secured to housing with two center pin tamper resistant screws. Tamper resistant tool included. With hospital grade push button on-off switch. Indoor use. Rated 120V only. Must add Option -120. With duplex hospital grade GFCI installed on one side. White. Indoor use. Rated 120V only. Must add Option -120. With duplex hospital grade GFCI installed on both sides. White. Indoor use. Rated 120V only. Must add Option -120. With duplex hospital grade GFCI installed. Indoor use. Rated 120V only. Must add Option -120. With duplex hospital grade receptacle on one side. White. Indoor use. Rated 120V only. Must add Option -120. With duplex hospital grade receptacle on both sides. White. Indoor use. Rated 120V only. Must add Option -120. With duplex hospital grade receptacle installed. Indoor use. Rated 120V only. Must add Option -120. .187” high strength acrylic prismatic lens and door instead on one side. Louvers on other side.
Faceplate Finishes -35 -37 -38 -94
Natural aluminum (silver) acrylic enamel. Dark Bronze acrylic enamel. Black acrylic enamel. Custom color/finish. Specify. Consult factory.
Other -84 -99 -FF
Wired for two circuits. Special modification. Consult factory. Fastener free faceplate / trim. No visible hardware. (UL Damp listed only)
Optional filter colors
Circadian Red / Amber Option -RA
Tiger Orange Option -OR
Wolverine Maize Option -YE
Spartan Green Option -GE
Lion Blue Option -BL
Custom Color Filter Option -CF
(See specification sheets for availability and details.)
NightLights / ChartLights & StepLights: Ordering
MUST SPECIFY
OPTIONAL
Product Number
Voltage
Options
MNT-07912
-120 (120 volts) -277 (277 volts) -97 (Specify other)
See “Options” above
www.kirlinlighting.com
Ordering Example: MNT-07912-120-34-GF
Page 63
Our Legacy of Leadership in Healthcare Lighting 1970’s
With the assistance of Dr. Michael DeBakey of the Baylor College of Medicine, Kirlin pioneers recessed motorized medical lighting.
1980’s
Kirlin takes the lead in MRI lighting, utilizing our exclusive aluminum housings and trims
1990’s
Kirlin patents the INFRALITE® Motorized Remote Controlled Lighting Systems.
2000’s
Kirlin introduces our first sealed & gasketed (IP65) downlights and exam lights and LED NightLights
2011
Kirlin pioneers the first and only turn-key LED lighting system for MRI suites called SmartLED™ MRI Lighting.
2015
Kirlin introduces OPTeLED™, the first high-performance motorized LED lighting system.
2016
Award winning INFRALED® 60 launched, taking LDR lighting to the next level... Delivering cool light at angles up to 60° utilizing Kirlin’s exclusive OPTeCOLOR™ medical grade LEDs. INFRALED® for ICU, cardiac cath, patient exams also introduced and specified globally.
ARRA
QUALIFIED
COMPLIANT
Designed, Manufactured and Assembled in the United States of America