Since 1895
Bulletin 16OPT
IES Award Winning! Lighting Innovators
Motorized led medical lighting
OPTeCOLOR Ultra-High CRI (95+) and R9 (85) Cool Beam Technology
FULLY RECESSED LED MOTORIZED PATIENT LIGHTING WITH WALL CONTROL FOR DIRECTION AND INTENSITY OF LIGHT
www.kirlinlighting.com 3401 E. Jefferson Ave. Detroit, MI 48207-4232
Palomar Medical Center, Escondido, CA
Motorized Patient Lighting by Kirlin
ARRA
QUALIFIED
MRR-12640 (Two Light System) MRR-12642 (One Light System)
Motorized Medical
LED Lighting Systems
Up to 9300 Footcandles Ultra-High Color Rendering (95+) and R9 (85) OPTeCOLOR™ & Cool Beam High Angle Illumination (Up to 50°) 60,000 Hour Life (L70)
LIGHT FIXTURES Fully recessed fixtures with architectural trims are unobtrusive, providing a safe environment for clinicians and patients, and inconspicuous, creating a home-like atmosphere. ™
rd
Ga
Bio
IP65
BioGard™ anti-microbial finish inhibits the growth of pathogens. Compact and smooth trim and lens are easy to clean. Sealed IP65 trim and lens available to prevent the transmission of pathogens through the fixture. See Option -IP.
All components are modular and fully serviceable through the aperture.
LEDs OPTeCOLOR™ LEDs deliver ultra-high CRI (95+) and R9 (85) for accurate tissue color rendering. Cool beam does not project heat toward the room, assuring patient and practitioner comfort and avoiding tissue desiccation. Precision optics deliver optimal contrast ratio, maximize luminaire efficiency and beam control while minimizing glare for clinician and patient. 60,000 hours long life (L70) dramatically reduces maintenance frequency and cost compared to traditional sources with typical life of 2000 hours. Redundancy of components ensures at least 50% illumination at all times.
WALL CONTROL Joystick permits one-step, quick and precise aiming of each lighthead wherever desired. Independent control of each lighthead permits adjustable pattern of superimposed beams or dual task illumination. Intensity of light is instantaneously adjusted from 100-10% (0-10V CCR dimming) with convenient slide dimmer.
MRR-12640
MRR-12642
ANGLE OF ILLUMINATION Each lighthead rotates 360° and tilts up to 35° permitting full coverage of the patient. Two light system (MRR-12640) provides higher light levels and minimizes shadowing. Optional 15° bottom pan (Option -81) allows lighthead to be tilted up to 50° for high angle illumination or to accommodate fixture location further from the bed.
www.kirlinlighting.com
Color Rendering and R9
Motorized Medical
LED Lighting Systems
High CRI is only part of the color rendering story. CRI only measures a light source’s ability to render pastel colors, excluding important saturated colors like red (R9). High R9 values are critical for accurate patient diagnosis and treatment. Kirlin OPTeCOLOR™ LEDs deliver both ultra-high CRI (95+) and R9 (85) lighting.
Performance
Low CRI & Low R9
High CRI & High R9
Footcandle Distribution Data - MRR-12640 (Two Light System) 4' Spacing 3’
2’
1’
CL
1’
2’
3’
2’
3’
2’
1’
CL
1’
2’
3’
1’
3’
2’
1’
CL
1’
2’
3’
1’
CL
8244 5141 299 78 46
2’
1’
1’
CL
6360 4557 357 81 41
2’
CL
4934 3928 436 87 39
1’
1’
2’
2’
2’
fc on Task: 8’ Ceiling 3’ Work Plane
fc on Task: 9’ Ceiling 3’ Work Plane
fc on Task: 10’ Ceiling 3’ Work Plane
Footcandle Distribution Data - MRR-12642 (One Light System) 3’
2’
1’
CL
1’
2’
3’
2’
3’
2’
1’
CL
1’
1’ 5665 734 68 29 16
CL 1’
2’
3’
2’
3’
2’
1’
CL
1’
2’
3’
1’ 3741 2088 133 34 20
CL 1’
2’ 1’
CL
2798 1904 163 37 18
1’
2’
2’
2’
fc on Task: 8’ Ceiling 3’ Work Plane
fc on Task: 9’ Ceiling 3’ Work Plane
fc on Task: 10’ Ceiling 3’ Work Plane
CE & FCC Compliance: Meets IEC/EN 60601-1-2 electromagnetic compatibility standard for medical electrical equipment. FCC Part 15 certified for EMI/RFI emissions
For more information, including Specification Sheets and Owner’s Manuals, please visit www.kirlinlighting.com or call your local Kirlin Sales Representative.
ARRA
QUALIFIED
Designed, Manufactured and Assembled the U.S.A.
www.kirlinlighting.com
Applications
Motorized Medical
ICU / CCU / PATIENT ROOM / ED / CATH LAB
LED Lighting Systems
24”
MRR-12640 Two Light System
24”
23° (35° Max)
Up to 8244 fc on the Task from 64”
23° (35° Max)
96”
9” Diameter Beam on Patient
72” 36”
MRR-12642 One Light System Up to 5665 fc on the Task from 60” Children’s Hospital Colorado Denver, CO
NICU
Motorized Patient Lighting by Kirlin
96”
72”
8” Diameter Beam on Patient
36”
24”
MRR-12640 Two Light System Up to 9275 fc on the Task from 60” 8” Diameter Beam on Patient
23°
24”
32”
23°
30°
96”
72”
40”
University of Michigan C.S. Mott Children’s Hospital Ann Arbor, MI
Options Input Power: SPECIFY
-120 120V (50-60Hz) input and thermal protector. -58 277/120 volt stepdown transformer for 277 volt line input, prewired into fixture; with 120 volt thermal protector. -97 For other input supply voltages, consult factory.
illumination in one direction. Maximum recessed depth 15-1/8”. -87 Custom length (> 35 feet) plenum rated wall control cables (4 for MRR-12640/ 2 for MRR-12642). Specify length in feet. OPTeCOLOR™ (CCT) -94 Custom color self-flanged flare trim instead. Consult factory. -41K 4100°K instead of 3500°K. 95+ CRI. -99 Special modification. Consult factory. -50K 5000°K instead of 3500°K. 95+ CRI. IP65 -IP IP65 rated trim and lens. Trim and Other -SE Fixture modified for seismic anchorage -32 White oversize trim ring. Specify O.D. (by others). Meets California OSHPD and International Building Codes. -81 15° bottom pan achieves 50° high angle
-98 347/120 volt stepdown transformer for 347 volt line input, prewired into fixture; with 120 volt thermal protector. Adds 10 Watts to each fixture load.
3401 East Jefferson Avenue • Detroit, Michigan 48207-4232 313-259-6400 • 313-259-3121 • info@kirlinlighting.com • www.kirlinlighting.com