Since 1895
Bulletin 13CMH2
Innovating Design and Performance
JW Marriott Grand Rapids, MI. Luminaires by Kirlin. Gary Steffy Lighting Design
T4 • T4.5 • T6 Ceramic Metal Halide Lighting
SPOT • NARROW FLOOD • MEDIUM FLOOD • WIDE FLOOD DISTRIBUTIONS
Downlights, Adjustables, Wall Washes 20 • 39 • 70 • 100 • 150 Watts Recessed Round and Square www.kirlinlighting.com
Table of Contents Page Why Choose Kirlin Ceramic Metal Halide? . . . . . Kirlin Specifications
T4.5 70W, 39W, 20W and
T4*
Round
39W, 20W
3-5 4”
HRR-04300
6”
HRR-06301
4”
HRR-04302
6”
HRR-06303
V
4”
HRR-04304
H
6”
HRR-06305
4”
HRS-04310
6”
HRS-06311
4”
HRS-04312
6”
HRS-06313
V
4”
HRS-04314
H
6”
HRS-06315
H
6”
HRR-06322
6”
HRR-06321
7”
HRR-07323
6”
HRR-06325
7”
HRR-07328
6”
HRR-06326
7”
HRR-07329
Downlights
V
Adjustables
V
6
Wall Washes
Luminaires
Square
Downlights
V
Adjustables
V
7
Wall Washes
T6
Downlights
150W, 100W 70W, 39W, 20W
V
Luminaires Round
Adjustables
V
Wall Washes
H
Vandal Resistant
H
7”
HRV-07327
V
6”
HRS-06341
H
6”
HRS-06342
Adjustable
V
6”
HRS-06344
Wall Wash
H
6”
HRS-06346
8
Downlights
9
Square
Options . . . . . Lamp Guide . . . . . Why Choose Kirlin?
10-12
* Add Option -T4 to standard T4.5 designs: 39 watt standard or with -T4-43 (20 watt). Page 2
www.kirlinlighting.com
Why Choose Kirlin Ceramic Metal Halide? State of the Art Technology Kirlin’s Ceramic Metal Halide (CMH) represents state-of-the-art, point source, HID lighting technology. Ceramic arc tubes deliver significant improvements over traditional pulse start silica designs. These benefits allow CMH lamps to be more compact even as they accommodate higher density lamp chemistry (mercury, argon, and metal halide salts) and much higher operating temperatures, offering end users the following important advantages: Longer Life: Lamp and Luminaire Arc tube operating temperatures can exceed 1200° Kelvin, as the metal halide salts within the hot plasma become partly vaporized. In a traditional silica lamp these plasma gases can penetrate the arc tube wall, leading to material depletion, inconsistent performance and shorter life. Ceramic materials offer superior containment and operating stability throughout the plasma phase without the deleterious outcomes of silica lamps. And, when operated with electronic ballasts, CMH reliably delivers 12,000 to 15,000 hour lamp life. Kirlin then wraps this technology in an acrylic enameled, rustproof, all-aluminum housing, allowing electrical components to operate 5°C cooler ~ extending ballast life up to 50%! Constant Color and Consistent Lumen Output The same features that allow CMH lamps to achieve longer life also provide advantages in improved color and output consistency. The superior wattage and voltage control offered by electronic ballasts yields lamp starting and run-up characteristics which deliver improved lumen depreciation and color maintenance over the life of the lamp. CMH lamps provide up to 80% of initial lumen output near end of life, with color maintenance within ± 150° Kelvin. Increased Fixture Efficiency with Multiple SC Choices
Atlantis The Palm, Dubai, United Arab Emirates Lighting Designer: Craig Roberts Associates Kirlin Luminaires: HRR-06325 and HRR-07328
The strength of the ceramic arc tube allows for compact point sources, permitting precise optical designs and greater fixture efficiencies. Kirlin’s proprietary optics take advantage of this benefit, providing excellent performance across a wide variety of beam patterns. Spacing Criteria (SC) can range from 0.1 to 1.4, giving the designer a complete palette to create a variety of effects. And with their improved chemistry and compact size, CMH systems achieve some of the highest luminaire efficacies available…up to 117 LPW.
High Color Rendering and Warmer Color Sparkling, crisp, white light… The higher density and improved chemistry in CMH lamps results in dramatically improved color rendering, with CRIs into the mid 90’s. In addition, CMH offers a comfortable range of CCTs from warm 3000° to cooler 4200° Kelvin. Quiet Operation All Kirlin CMH electronic ballasted luminaires maintain a sound class rating of “A” (<24 dB), ensuring they may be installed with confidence in the most demanding quiet environments. Environmental Sustainability Lighting accounts for nearly 20% of our annual energy usage. So why not take advantage of Kirlin CMH systems that offer higher efficacy, longer life, and superior performance compared with traditional metal halide systems? CMH permits fewer fixtures and/or lower wattages, saving watts per square foot – and that’s good for the environment. Kirlin luminaires are built to last but are also fully sustainable and upgradeable over time. As technology improves, so can your lighting system. That’s great for our environment – and the owner’s pocketbook! Great color, superior color rendering, fewer lamp replacements, consistent performance and lower energy usage makes Ceramic Metal Halide designs by Kirlin the perfect choice. Doesn’t every customer deserve great performance and the lowest total cost of ownership?
Since 1895 ~ Our Only Tradition is Quality www.kirlinlighting.com
Page 3
Kirlin Specifications Luminaires
90˚
• Round and Square Designs 75˚ 10500 • Downlights 60˚ - Up to 4 SC per luminaire (from 0.1 to 1.4) 21000 • Adjustables 45˚ 5000 - Swivel 358° and tilt up to 45° 31500 10000 - Up to 3 SC per luminaire (from 0.2 to 0.8) 0˚ 15˚ 30˚ • Wall Washes 15000 - 25° for optimal wall washing 0˚ • Vandal Resistant Downlight - Reinforced housing and seamless self-flanged tamperproof trim - Trim secured to internal brackets with tamper resistant screws - Dual layer tempered lenses: prismatic C#73 above 3/16” clear glass
90˚ 75˚ 90˚
60˚ 45˚ 15˚
30˚
75˚
3000
60˚
6000 9000 0˚
45˚ 15˚
30˚
Reflectors / Trims / Lenses • Open Appearance round and square designs • Reflectors: High efficiency ellipsoidal or parabolic specular Alzak® aluminum • Cones: Low brightness specular or SofTex™ Alzak® aluminum, self-flanged • Lenses: UV absorbing tempered glass (microprismatic, C#73 and frosted linear)
Lamps / Sockets • Designed for bi-pin metal halide lamps: - T4 up to 39W (twist-and-lock) - T4.5 up to 70W (bi-pin) - T6 up to 150W (bi-pin) • Up to 95 CRI, 12,000-15,000 hour life • For lower wattages see Option -43 • See “T4, T4.5 and T6 Metal Halide Lamp Guide” on page 11 • Pulse rated sockets with porcelain body and silicone leads: - GU6.5 base for T4 - G8.5 base for T4.5 - G12 base for T6
Page 4
www.kirlinlighting.com
Kirlin Specifications
Electronic Ballast Assembly • Full electronic circuitry for constant wattage. Ensures consistent color, performance and long life • Input voltage 120V–277V, 50/60 Hz. See Options for others • Minimum starting temperature -20°C/-4°F • Thermally protected. Internally fused • Power factor greater than 90%. Input current THD less than 15% • Maximum 90°C operation, Sound rating: A • Includes lamp end-of-life detection and shutdown circuit
Housing • Acrylic enameled 100% aluminum • Rustproof and corrosion resistant. Exceeds 1000 hour ASTM 5% salt spray test • Cool: Dissipates heat across entire surface area • Entire luminaire serviced from below through the aperture • Built-in plaster frame
Outlet Box • Prewired 14 GA (NEC) galvanized steel • UL listed • With removable insulated cover • 1/2” and 3/4” knockouts
Installation • 27” galvanized hanger bars supplied (2) • Fully adjustable universal mounting brackets supplied (2) • Recesses indoor or outdoor in covered locations
UL, C-UL (Canada) Listings • Wet, damp or dry locations, covered ceilings • Through-branch circuit conductors (6 #12) • Type IC standard on 20W models and select 39W models
Three Year Limited Warranty: Complete standard fixture, including ballast
www.kirlinlighting.com
Page 5
70W T4.5 and 39W T4 Round* 4” 90˚
Downlights
70W T4.5 WFL (std)
750
SC: 1.1
1500
EFF: 62%
2250 0˚
75˚ 60˚ 45˚ 15˚
30˚
Cone of Light ▲ Dist 6 8 10 12 14 16
FC
Dia
62.1 34.9 22.3 15.5 11.4 8.7
6.4 8.6 10.7 12.8 15.0 17.1
HRR-04300 6” 90˚
70W T4.5 MFL (std)
2100
SC: 0.7
4200
EFF: 74%
6300 0˚
75˚ 60˚ 45˚ 15˚
30˚
Cone of Light ▲ Dist
FC
Dia
6 8 10 12 14 16
173.3 97.5 62.4 43.3 31.8 24.4
4.6 6.1 7.7 9.2 10.7 12.3
HRR-06301 4” 90˚
Adjustables
70W T4.5 NFL (std)
5000
SC: 0.4
10000
EFF: 50%
15000 0˚
15˚
30˚
90˚
SC: 0.4 EFF: 52%
16500 0˚
Wall Washes
2600 3900 0˚
HRR-04304
15˚
30˚
HRR-06305 See page 10 for Options. Page 6
EFF: 52%
1600 2400 0˚
-MFL
SC: 0.8 EFF: 48%
-SPT
-MFL
SC: 0.2 EFF: 52%
SC: 0.8 EFF: 51%
-43 (39W)
60˚ 45˚ 15˚
30˚
90˚ 800
SC: 0.4 EFF: 70%
75˚
6” 70W T4.5
SC: 0.2 EFF: 67%
45˚
90˚
EFF: 41%
-NFL
60˚
4” 1300
-SPT
75˚
HRR-06303
70W T4.5
SC: 0.7 EFF: 59%
45˚
70W T4.5
11000
SC: 0.3 EFF: 61%
60˚
6” 5500
-MFL
75˚
HRR-04302
NFL (std)
-SPT
EFF: 43%
-43 (39W) ▲ Cone of Light Key
75˚
15˚
60˚
Dist Distance from fixture in feet FC Footcandles at nadir (0°) Dia Circle of light at 50% of FC
45˚
Dia (in feet) shown is where FC value is half the FC at nadir.
30˚
EFF: 53%
* Lower wattages available with Option -43. www.kirlinlighting.com
70W T4.5 and 39W T4 Square* 4” 90˚
Downlights
70W T4.5 WFL (std)
950
SC: 1.1
1900
EFF: 65%
2850 0˚
75˚ 60˚ 45˚ 15˚
30˚
Cone of Light ▲ Dist 6 8 10 12 14 16
FC
Dia
76.7 43.2 27.6 19.2 14.1 10.8
7.1 9.5 11.9 14.3 16.7 19.1
HRS-04310 6” 90˚
70W T4.5 MFL (std)
1500
SC: 0.8
3000
EFF: 74%
4500 0˚
75˚ 60˚ 45˚ 15˚
30˚
Cone of Light ▲ Dist
FC
Dia
6 8 10 12 14 16
122.5 68.9 44.1 30.6 22.5 17.2
5.2 7.0 8.7 10.5 12.2 13.9
HRS-06311 4” 90˚
Adjustables
70W T4.5 NFL (std)
3500
SC: 0.4
7000
EFF: 53%
10500 0˚
15˚
30˚
90˚
SC: 0.4 EFF: 55%
15000 0˚
Wall Washes
2600 3900 0˚
HRS-04314
15˚
30˚
HRS-06315 See page 10 for Options. www.kirlinlighting.com
EFF: 56%
1500 2250 0˚
-MFL
SC: 0.8 EFF: 55%
-SPT
-MFL
SC: 0.2 EFF: 55%
SC: 0.8 EFF: 53%
-43 (39W)
60˚ 45˚ 15˚
30˚
90˚ 750
SC: 0.3 EFF: 63%
75˚
6” 70W T4.5
SC: 0.1 EFF: 63%
45˚
90˚
EFF: 43%
-NFL
60˚
4” 1300
-SPT
75˚
HRS-06313
70W T4.5
SC: 0.7 EFF: 62%
45˚
70W T4.5
10000
SC: 0.4 EFF: 61%
60˚
6” 5000
-MFL
75˚
HRS-04312
NFL (std)
-NFL
EFF: 44%
-43 (39W) ▲ Cone of Light Key
75˚
15˚
60˚
Dist Distance from fixture in feet FC Footcandles at nadir (0°) Dia Circle of light at 50% of FC
45˚
Dia (in feet) shown is where FC value is half the FC at nadir.
30˚
EFF: 57%
* Lower wattages available with Option -43. Page 7
150W T6 Round* 6”
WFL (std)
1700
SC: 1.1
3400
EFF: 60%
HRR-06321 6”
5100 0˚
75˚ 60˚ 45˚ 15˚
Downlights
WFL (std)
2500
SC: 1.1
5000
EFF: 63%
7”
7500 0˚
75˚ 60˚ 45˚ 15˚
WFL (std)
1600
SC: 1.3
3200
HRR-07323 6”
4800 0˚
75˚ 60˚ 45˚ 15˚
SC: 0.3 EFF: 41%
HRR-06325 7”
90˚
SC: 0.3 EFF: 46%
HRR-07328
FC
Dia
6 8 10 12 14 16
140.7 79.1 50.6 35.2 25.8 19.8
6.3 8.4 10.6 12.7 14.8 16.9
-MFL
SC: 0.4 EFF: 61%
SC: 0.8 EFF: 60%
-NFL
-MFL
SC: 0.3 EFF: 64%
SC: 0.8 EFF: 62%
Cone of Light ▲ Dist
FC
Dia
6 8 10 12 14 16
170.2 95.7 61.3 42.5 31.3 23.9
6.9 9.2 11.4 13.7 16.0 18.3
Cone of Light ▲ Dist
FC
Dia
6 8 10 12 14 16
132.4 74.5 47.7 33.1 24.3 18.6
7.6 10.2 12.7 15.3 17.8 20.4
-SPT
-MFL
SC: 0.2 EFF: 43%
SC: 0.6 EFF: 38%
-SPT
-MFL
SC: 0.2 EFF: 46%
SC: 0.6 EFF: 43%
45˚ 15˚
30˚
90˚ 75˚
11000
60˚
22000 33000 0˚
Dist
-NFL
60˚
20000 30000 0˚
Cone of Light ▲
75˚
10000
150W T6 NFL (std)
45˚ 15˚
6”
Wall Washes
30˚
150W T6 NFL (std)
30˚
90˚
150W T6
3000
EFF: 42%
6000 9000 0˚
HRR-06326
75˚ 60˚ 45˚ 15˚
7”
30˚
90˚
150W T6 EFF: 47%
HRR-07329 See page 10 for Options. Page 8
30˚
90˚
150W T6
EFF: 64%
30˚
90˚
150W T6
HRR-06322
Adjustables
90˚
150W T6
75˚
3500
60˚
7000 10500 0˚
45˚ 15˚
▲ Cone of Light Key
Dist Distance from fixture in feet FC Footcandles at nadir (0°) Dia Circle of light at 50% of FC Dia (in feet) shown is where FC value is half the FC at nadir.
30˚
* Lower wattages available with Option -43. www.kirlinlighting.com
Vandal Resistant
150W T6 Round Vandal Resistant* 7” 90˚
150W T6 WFL (std)
1600
SC: 1.1
3200
EFF: 55%
4800 0˚
75˚ 60˚ 45˚ 15˚
30˚
Cone of Light ▲ Dist
FC
Dia
6 8 10 12 14 16
131.6 74.0 47.4 32.9 24.2 18.5
6.9 9.2 11.5 13.9 16.2 18.5
HRV-07327
150W T6 Square* 6” 90˚
Downlights
150W T6 MFL (std)
5000
SC: 0.8
10000
EFF: 62%
15000 0˚
75˚ 60˚ 45˚ 15˚
30˚
Cone of Light ▲ Dist
FC
Dia
6 8 10 12 14 16
356.9 200.8 128.5 89.2 65.6 50.2
4.9 6.5 8.2 9.8 11.5 13.1
-SPT
-NFL
SC: 0.2 EFF: 62%
SC: 0.4 EFF: 60%
HRS-06341 6” 90˚
150W T6 WFL (std)
1800
SC: 1.1
3600
EFF: 65%
5400 0˚
75˚ 60˚ 45˚ 15˚
30˚
Cone of Light ▲ Dist
FC
Dia
6 8 10 12 14 16
146.2 82.2 52.6 36.5 26.8 20.6
7.3 9.8 12.2 14.7 17.1 19.6
HRS-06342 6” 90˚
Adjustable
150W T6 NFL (std)
10500
SC: 0.4
21000
EFF: 54%
31500 0˚
-SPT
-MFL
SC: 0.2 EFF: 57%
SC: 0.7 EFF: 57%
75˚ 60˚ 45˚ 15˚
30˚
HRS-06344 6”
Wall Wash
90˚
150W T6
3000
EFF: 47%
6000 9000 0˚
75˚ 60˚ 45˚ 15˚
▲ Cone of Light Key
Dist Distance from fixture in feet FC Footcandles at nadir (0°) Dia Circle of light at 50% of FC Dia (in feet) shown is where FC value is half the FC at nadir.
30˚
HRS-06346 See page 10 for Options. www.kirlinlighting.com
* Lower wattages available with Option -43. Page 9
Options Distributions
-SPT Spot distribution. -NFL Narrow flood distribution. -MFL Medium flood distribution.
Lower Reflector
-30 All White. -31 White flange (only). -32 White trim extender to cover larger ceiling opening. Specify outer dimension. -45 Gasket above flange. -69 Wheat specular Alzak. Consult factory. -70 Clear SofTex™. -77 Pewter SofTex™. Consult factory. -91 Wheat SofTex™. Consult factory. -93 Pewter specular Alzak. Consult factory. -94 Custom color. Consult factory.
Relays, Standbys, Lamps
-49 Extra circuit DCB socket (up to 75W). Also see Option -LS. -65 Electronic standby system and DCB socket (up to 75W). Provides immediate light until CMH lamp restrikes. Also see Options -66 and -LS. -66 Electronic time delay standby system and DCB socket (up to 75W). Provides light until CMH lamp reaches 70% output. Also see Option -LS.
The Pinnacle at Symphony Place, Nashville TN Architect: Pickard Chilton
-LP With lamp. Specify source, wattage, color temperature / brand. 3000°K standard; consult factory for others. -LS With T4 DCB tungsten halogen standby lamp (75W). Use only with Options -49, -65 or -66.
Wattage and Voltage
-43 Lower wattage. Specify one of the following:
T6
T4.5 T4
100W 70W 39W 20W 39W 20W 20W
Specify Voltage Type IC Specify Voltage Type IC Type IC
-347 347 volt. -97 Other input voltage instead. Consult factory. -T4 Converted to GU6.5 base for T4 lamp 39W standard. Specify voltage. Add Option -43 for 20W Type IC.
Other Options
-79 Extension collar for up to 2” thick ceilings. Consult factory. -99 Special modification. Consult factory. -TA Top access. Consult factory.
Kirlin Luminaires: HRS-06341
Page 10 www.kirlinlighting.com
Lamp Guide Brand
Initial Lumens
Mean Lumens
Life (Hours)
CCT
CRI
GE
1650
1066
12,000
3000
81
PHILIPS
1800
1400
15,000
3000
85
39
GE
3400
2300
10,000
3000
88
2600
12,000
4000
90
39 / 35
PHILIPS
3900
3300
15,000
3000
87
GE
1650
1090
12,000
3000
80
PHILIPS
1800
1550
15,000
3000
85
SYLVANIA
1700
1275
12,000
3000
82
3400
2300
15,000
3000
84
3200
2600
15,000
4000
90
4000
3500
15,000
3000
90
3300
2640
12,000
4200
85
SYLVANIA
3400
2720
12,000
3000
82
GE
6200
4400
15,000
3000
83
4600
15,000
4200
90
7650
6700
15,000
3000
90
5900
3840
12,000
4200
90
SYLVANIA
6300
5040
15,000
3000
95
PHILIPS
1800
1550
15,000
3000
85
4000
3500
15,000
3000
90
3300
2800
12,000
4200
84
3400
2720
12,000
3000
82
3300
2640
12,000
4200
90
6200
4700
15,000
3000
83
6300
4700
15,000
4200
91
7650
6700
15,000
3000
90
6600
4620
12,000
4200
92
7000
5600
12,000
3000
87
6400
5120
12,000
3000
95
6700
5360
12,000
4200
93
PHILIPS
11,000
9680
15,000
3000
90
SYLVANIA
9500
7600
15,000
3000
85
14,000
11,000
12,000
3000
82
13,000
11,000
12,000
4200
94
14,000
9800
12,000
3000
88
12,000
8900
12,000
4200
96
14,500
11,600
12,000
4200
95
Lamp
Watts
T4
20
T4.5 20
GE 39
70
T6
20
PHILIPS
PHILIPS
PHILIPS 39 SYLVANIA GE
70
PHILIPS
SYLVANIA
100
GE 150
PHILIPS SYLVANIA
www.kirlinlighting.com
Page 11
Why Choose Kirlin?
5 5 8” Precision formed all-aluminum Alzak® trims for efficiency, aesthetics and strength. Optimized contour of ellipsoidal or parabolic specular upper reflectors and low brightness specular or SofTex™ self-flanged lower cones.
Acrylic enameled all-aluminum housings are rustproof and corrosion resistant for exceptional durability in humid, wet, salt and halogen (natatorium) environments.
45000
90˚
90˚
90˚
75˚
75˚
75˚
60˚
90000
45˚
135000 0˚
15˚
30˚
12500
60˚
25000 37500 0˚
45˚ 15˚
30˚
5000
60˚
10000 15000 0˚
45˚ 15˚
30˚
13 shallow depth (5 5/8” deep) luminaires for installation in plenums with limited space.
Adjustables swivel 358° and tilt up to 45° for maximum flexibility. Wall washes fixed at 25° provide broad, even illumination of vertical surfaces.
90˚ 75˚
1800
60˚
3600 5400 0˚
45˚ 15˚
30˚
Specified optics provide efficiencies up to 77% and a wide selection of SC (from 0.1 to 1.4) to meet the requirements of any lighting application.
Complete family of architectural 4” and 6” round and square downlights, adjustables and wall washes.
Components operate 5°C cooler and last 50% longer in Kirlin’s aluminum housing than in an identical steel housing.
Designed, manufactured and assembled in the United States.
ARRA
QUALIFIED
COMPLIANT
3401 East Jefferson Avenue, Detroit MI 48207-4232 313-259-6400 • FAX: 313-259-3121 • www.kirlinlighting.com • info@kirlinlighting.com