Conduct a Site Measure and Site Analysis Deng Luolin Task 1B: Tools and Equipment Checklist Required

Not Required

Dumpy level Staff Tripod Tap measure Camera Note pad/clip board Paper Pens / pencil Laser measure Spirit level

Operation


Conduct a Site Measure and Site Analysis Deng Luolin Task 1C: P.P.E Checklist Required

Not Required

High visit vest Hat / helmet Boots Glass (sun) /protection Camera Gloves Fire aid kit Sunscreen Harness

Operation



Conduct a Site Measure and Site Analysis Deng Luolin Task lE: Site Inspection Checklist Site fall and topography

Identification of boundaries, and issues with respect to fencing Services including Water, Sewerage, Drainage, Electricity, Gas, and Communications

Existing structures, on site or to adjoining properties, recording set-backs

Considerations to Set-backs for height, and natural light The location of secluded private open space

X

Access Vegetation & Environment which may regulate the building for the proposed project Visible soil conditions OH & S issues which has an impact on building methods and project costs Protection Works, which are to be addressed Any relevant issues from your research of legislation, Building Codes, Australian Stand ards, Industry Publications, or any publication with respect to building compliance

✓ ✓ ;(

X






n Swa

ø 225

ø 225

30 ! ?

Date

28/7/2019 20

600ø

Street Drummond

675ø

300ø 30 0ø

15 0ø

43H6

40

80 m

DISCLAIMER: The location of underground assets and services is approximate and their position and existence should be proven on site by hand excavation. No guarantee is given that all existing assets and services are shown.

t

ø 225

ø 375

ø 225

Melway Reference

tree e S b o Tr La

ø 375 225ø

ø 225

LEGEND Pipe Diam. U/G Litter Trap Irrigation Controller In-Ground Sensor Electrical Conduit Drainage Pipe

WARNING: ø

" T

! ?

In ground sensors are present in this area please call City of Melbourne 7 days prior to any digging roadworks. Contact: Parking & Traffic Compliance coordinators on (03) 9658 9658

´

25ø ø 2 225

ø 375

ø 225

Title

0

ø 225

et Stre

ø 225 225ø

CITY OF MELBOURNE ENGINEERING SERVICES BRANCH UNDERGROUND ASSETS AND SERVICES INFORMATION

Map Scale

ø 225

sell

150 ø

ø 300

ø 300

150ø

Rus

ø 300

ø 300

ø 300

t

300ø 300ø 0ø ø 30 300

ø 300

ø 150

ett e ck A'B

e Stre

300ø 300ø

! ?

5ø 22

ø 300

ø 100

0ø 30

ø 300

ø 300 5ø ø 22 225

ø 525

600ø

Lygon Str eet 300ø

300ø

ø 300

et Stre 225ø

t

0ø 30

225ø

ø 225 0ø

ø 300

300ø 300ø 300ø 450ø

75ø ø 3 450

ø 525

600ø

375ø

Cardigan 600ø

450ø

450ø

" T

300ø

ø 300

ston 225ø

675ø

ø 600

Victoria S treet 675ø

e ø Stre 300 lin k n 300ø Fra

ø 225

300ø

300ø

225ø 675ø

675ø

5ø 22

! ?

375ø

300ø

600ø 600ø

675ø

300ø

600ø

600ø

375ø

" T

300ø

300ø

300ø

300ø

300ø

225ø

y Street

525ø

300ø

225ø

Street

300ø

300ø

Swanston

300ø

300ø 300ø 300ø

Queensbe rr

525ø

Street

150ø

225ø 225ø

600ø

300ø

525ø

225ø 225ø 22 5ø

0ø 30

ø 225


Dial Before You Dig City West Water Plan Request Friday, 2 August 2019

TO:

Miss Luolin Deng 6 Colebrook Avenue Mount Waverley 3149 VIC lolly_deng0530@icloud.com

EMAIL / FAX:

FROM:

CWW Dial Before You Dig

EMAIL:

connections@citywestwater.com.au

Site Location details:

Victoria Street, Melbourne, VIC, 3000

SEQUENCE NUMBER 86289846

JOB NUMBER 16768212

Dear Miss Luolin Deng, Thank you for your Dial Before You Dig Request. Please find attached the Water and Sewerage plans as requested.

Important Information • The location of assets must be proved in the field by the applicant prior to the commencement of work. These plans do not indicate private services.

• City West Water does not guarantee and makes no representation or warranty as to the accuracy or scale of these

plans. This company accepts no liability for any loss, damage or injury by any person as a result of any inaccuracy in these plans.

• Assets labelled AC may contain asbestos material and therefore works on these assets must be undertaken in accordance with OHS (Asbestos) Regulations 2007.

• Metallic water mains and associated fittings may pose an electrocution hazard if electrical earth wires have been

connected to the property service or water main. The contractor shall ensure that adequate electrical testing is carried out prior to working on these mains. If a positive reading is recorded the contractor shall cease all works and notify the relevant power distributor, the customer and City West Water.

• Minimum horizontal and vertical clearances ( edge to edge ) are required between your proposed works and City West

Water assets. Details of these minimum clearances can be obtained from City West Water’s website: http://www.citywestwater.com.au/documents/Guidelines_for_proposed_works_over_adjacent_to_water_authority_asse ts(1).pdf

• Any conflict with the minimum clearance to your proposed works should be referred to City West Water for advice.

Contact Information: • If you require more detailed plans, please contact as follows : ( Please note, the following services will incur a processing fee )

• • •

Sewer Detail Plan Asset Information Plan Property Service Plan ( Internal Pipes )

City West Water 13 16 91 City West Water 13 16 91 Casey Inspection 9835 5511

City West Water Corporation Locked Bag 350, St Albans Road Sunshine 3020 Enquiries:13 16 91


16768212:86289846 Victoria Street, Melbourne VIC 3000 Melway Reference: 43H6

Scale 1: 2577 Date: 02/08/2019

Disclaimer : The location of assets must be proved in the field by the applicant prior to the commencement of work. These plans do not indicate private services. City West Water Corporation does not guarantee and makes no representation or warranty as to the accuracy or scale of this plan. This company accepts no liability for any loss, damage or injury by any person as a result of any inaccuracy in this plan.


16768212:86289846 Victoria Street, Melbourne VIC 3000 Melway Reference: 43H6

Scale 1: 2577 Date: 02/08/2019

Disclaimer : The location of assets must be proved in the field by the applicant prior to the commencement of work. These plans do not indicate private services. City West Water Corporation does not guarantee and makes no representation or warranty as to the accuracy or scale of this plan. This company accepts no liability for any loss, damage or injury by any person as a result of any inaccuracy in this plan.


CitiPower Pty ABN 76 064 651 056 www.citipower.com.au

Head Office: 40 Market Street Telephone: (03) 9683 4444 Facsimile: (03) 9683 4499 DX 433 Melbourne Postal Address: Locked Bag 14090 Melbourne Victoria 8001 Australia

Powercor Australia ABN 89 064 651 109 www.powercor.com.au

<Enquiry Date> 02/08/2019 <Customer Reference Number 86289842 <Enquiry No> Miss Luolin Name> Deng Not Supplied <Customer company2> 6 Colebrookaddress> Avenue <Customer <Customer suburb/town> VIC <Customer state> 3149 <Customer postcode> Mount Waverley

Dear Customer Thankyou for your enquiry on 02/08/2019 <Enquiry Date> regarding the work at: <Worksite Address> <Worksite suburb/town> Victoria Street Melbourne

A SEARCH OF OUR RECORDS SHOWS THAT THERE ARE UNDERGROUND ELECTRICITY ASSETS WITHIN THE AREA OF YOUR REQUEST DO NOT PROCEED UNTIL YOU HAVE READ THIS NOTICE IN FULL The following information is attached for your reference: - Underground Electricity Asset location details - Underground Electricity Hazard Awareness Instructions To ensure that your proposed works do not impact on your safety or our assets please proceed as follows: - Read all attached documents and observe the Exclusion Zones defined in the Underground Electricity Hazard Awareness Instructions - Identify the locations of our Underground Electricity Assets from the attached documents

Are our Underground Electricity Assets located where you are planning to dig? YES - contact us for further advice. Contact details are available on the first page of the attached Underground Electricity Hazard Awareness Instructions (including Request for Site Visit)

NO - proceed with caution UNSURE - contact us for further advice. Contact details are available on the first page of the attached Underground Electricity Hazard Awareness Instructions (including Request for Site Visit) Please note that no work is to be undertaken in the vicinity of our Underground Electricity Assets that may breach the Exclusion Zones (as defined by the Underground Electricity Hazard Awareness Instructions) until the completion of a further technical assessment of the area. Upon receipt of your Request for Site Visit form you will be contacted by a responsible officer to assess your requirements. A site visit will be organised if required. During the site visit we will determine the location of our assets and any Permit to Work conditions applicable to your works. We will also be able to provide further details of any additional works which may be required to enable you to safely complete your proposed works. Please note that the Permit to Work site visit timeframes are subject to enquiry volumes and specific site locations, therefore it may require up to 10 working days to contact you and arrange a site visit Regards,

CitiPower & Powercor Dial Before You Dig (DBYD) response team

1


Dial Before You Dig (DBYD) Electricity Asset Location Information CitiPower/Powercor Locked Bag 14090, Melbourne VIC 8001 General Enquiries Telephone: 132 206 To:

(‘Enquirer’)

Not Supplied - Miss Luolin Deng <Contact Name> 6 Colebrookaddress> Avenue <Customer Mount Waverley <Customer suburb/town> VIC <Customer state> 3149 <Customer postcode>

Enquiry Details Utility ID

<Utility ID> 50013

Sequence Number

<Enquiry No> 86289842

Enquiry Date

<Enquiry date/time> 02/08/2019 15:41

Response

DANGER - Permit May Be Required

Address

<Worksite Address> Victoria Street <Worksite suburb/town> Melbourne

Location in Road

<Worksite Road Location> CarriageWay,Footpath,Nature Strip

Activity

<Activity desc> Planning & Design

Enquirer Details Customer ID

<Customer 1975052 id>

Contact

<Customer Miss Luolin Name> Deng

Company

<Customer company2> Not Supplied

Email

<Customer email> lolly_deng0530@icloud.com

Phone

<Customer phone> 61432430369

Mobile

<Customer mobile> Not Supplied

Enquirer Responsibilities This notification is valid for 28 days from the issue date. CitiPower/Powercor assets are critical infrastructure and great care must be taken to avoid asset damage and risk to public safety. The information supplied in the DBYD Response is intended to be indicative only. External parties should make their own enquiries to ensure the accuracy of the information, including but not limited to:

• • • • •

Check that the location of the dig site indicated is correct, if not you must submit a new enquiry. Should your scope of works change or the plan validity dates expire, you must submit a new enquiry. If you do not understand the plans provided please contact CitiPower/Powercor prior to works commencing. Always perform an onsite inspection to establish the presence of assets. Ensure you adhere to any State legislative requirements regarding Duty of Care and safe digging requirements.

Report any asset damage immediately on 132 206. Note: CitiPower/Powercor reserves the right to recover compensation for damages. Powered by

2


Date: 02/08/2019 <Enquiry Date>

Locality Map

Sequence No: 86289842 <Enquiry Number> <Worksite address> <Worksite suburb/town> Victoria Street Melbourne

MAP IS A GUIDE ONLY- REFER TO CABLE PLANS FOR ACCURATE ASSET LOCATIONS

1

<overview map> LEGEND: DBYD Work Area

SWER Substation

High Voltage Cable

Communication Cable

Zone Substation

Distribution Substation

Low Voltage Cable

Earth Cable

This map represents the location of the submitted DBYD Work Area and all CitiPower/Powercor responses are based on this location. It is the responsibility of the enquirer to ensure the accuracy of the DBYD Work Area.

0 0.03km <overview scalebar> Imagery sourced from Open StreetMaps

Powered by

3


Date: 02/08/2019 <Enquiry Date>

Sequence No: 86289842 <Enquiry Number>

Map 1 <stripmap sheet number> <Worksite address> <Worksite suburb/town> Victoria Street Melbourne MAP IS A GUIDE ONLY- REFER TO CABLE PLANS FOR ACCURATE ASSET LOCATIONS

P#

1 P#

# #

P#

P P P# P

P

P

P#

P P

P

P

P <stripmap> LEGEND: DBYD Work Area

SWER Substation

High Voltage Cable

Zone Substation

Distribution Substation

Low Voltage Cable

Communication Cable

Pole (Subtransmission)

Pole (LV)

Earth Cable

Pole (HV)

Property Boundary

This map represents the location of the submitted DBYD Work Area and all CitiPower/Powercor responses are based on this location. It is the responsibility of the enquirer to ensure the accuracy of the DBYD Work Area.

0 0.006km <stripmap scalebar> Imagery sourced from Open StreetMaps

Powered by

4


5


6


APA Group PO Box 6014 Halifax Street South Australia 5000 02/08/2019 <Enquiry Date> Company: <Customer Company2> <Customer name> Miss Luolin Deng 6 Colebrook address> Avenue <Customer <Customer suburb/town> Mount Waverley <Customer state> <Customer postcode> VIC 3149 lolly_deng0530@icloud.com <Customer email> Miss Luolin Deng Dear <Customer name> Sequence Number: Worksite Address:

86289845 <Enquiry No> Victoria <Worksite Street address> <Worksite suburb/town> Melbourne <Worksite state> <Worksite postcode> VIC 3000

Thank you for your Dial Before You Dig enquiry regarding the location of Gas Assets. We can confirm that the APA Group has Gas Assets in the vicinity of the above location. You are hereby notified that the attached Duty of Care requirements apply to any activity in the vicinity of Gas Assets operated by APA, please ensure you read and comply with all the relevant requirements. Should you have any questions with regards to the attached information please contact our Dial Before You Dig officer - 1800 085 628. Caution - Damage to gas assets could result in possible explosion and fire with the risk of personal injury. For Gas Emergencies please call 1800 427 532 Please find enclosed the following information: • • •

APA’s Duty of Care, If you are unclear of your obligations under these requirements please contact the APA Representative listed above immediately An overview map with your requested area highlighted to assist in identifying the location of APA’s Gas Assets A map(s) showing APA’s Gas Assets in the requested area, this information is valid for 30 days from the date of this response, please check this represents the area you requested, if it does not, please contact the APA Representative listed above immediately

Please Note: For some DBYD enquiries, you might receive 2 responses from the APA Group. Please read both responses carefully as they will relate to different assets. It is your responsibility to action all requirements set out in APA Group responses. Please take some time to review the entire response document and check the information supplied and please let us have any feedback by sending an email to DBYDNetworksAPA@apa.com.au or contacting us direct on 1800 085 628. Yours Faithfully, Dial Before You Dig Officer APA Group Email: DBYDNetworksAPA@apa.com.au

APA Group • PO Box 6014 Halifax Street SA 5000 • Email: DBYDNetworksAPA@apa.com.au • Template: VIC Affected July 2019 <Page1 xofy> Page of 4 • <Enquiry 02/08/2019 Date>


Duty of Care - Working Around Gas Assets General Conditions •

This location enquiry is valid for 30 days from the enquiry date

Expired locations, i.e., over 30 days from the date of this response, require a new Dial Before You Dig request to validate location information

The location information supplied in this document shall be used as a guide only. APA Group shall not be liable or responsible for the accuracy of any such information supplied pursuant to this request

It is the responsibility of the excavator to expose all Gas Assets, including Gas Services pipelines (See below), by hand (Please Note: Do not use vacuum excavation systems as damage to Gas Assets may occur). Gas Asset depths may vary according to ground conditions

Gas Service pipelines (inlet service) connecting Gas Assets in the street to the gas meter on the property are typically not marked on the map

This information has been generated by an automated system based on the area highlighted in your DBYD request and has not been independently verified. It is your responsibility to ensure that the information supplied in this response matches the dig site you defined when submitting your Dial Before You Dig enquiry. If the information does not match the dig site or you have any question, please contact APA immediately using the details listed on the first page and / or please resubmit your enquiry

For Gas Emergencies please call 1800 427 532

APA Group • PO Box 6014 Halifax Street SA 5000 • Email: DBYDNetworksAPA@apa.com.au • Template: VIC Affected July 2019 <Page2 xofy> Page of 4 • <Enquiry 02/08/2019 Date>


Name

Victoria Street <Worksite address> <Worksite suburb/town> Melbourne <Worksite postcode> 3000 <Customer Miss Luolin Deng name>

Email

<Customer email> lolly_deng0530@icloud.com

Site Address

Sequence No

86289845No> <Enquiry

1

<overview map> Scale 1: 6000 <overview scale> <north arrow> Enquiry Area

Map Key Area

APA Group • PO Box 6014 Halifax Street SA 5000 • Email: DBYDNetworksAPA@apa.com.au • Template: VIC Affected July 2019 <Page3 xofy> Page of 4 • <Enquiry 02/08/2019 Date>


Site Address

Victoria Street <Worksite address> <Worksite suburb/town> Melbourne <Worksite postcode> 3000

Sequence No

<Enquiry 86289845No>

Email

<Customer lolly_deng0530@icloud.com email>

Map Reference

Melways map type> <Worksite <Worksite map ref> 43H6

1

<stripmap> Map Key <stripmap key> 1

Scale 1:<stripmap scale> 1000

0 0.01km <stripmap scalebar>

APA Group • PO Box 6014 Halifax Street SA 5000 • Email: DBYDNetworksAPA@apa.com.au • Template: VIC Affected July 2019 <Page4 xofy> Date> Page of 4 • <Enquiry 02/08/2019

<north arrow>


Indicative Plans Issue Date:

02/08/2019

Location:

Victoria Street , Melbourne , VIC , 3000



Emergency Contacts You must immediately report any damage to nbn™ network that you are/become aware of. Notification may be by telephone - 1800 626 329.


To: <Contact Not Supplied Name> - Miss Luolin Deng <Customer 6 Colebrookaddress> Avenue <Customer Mount Waverley suburb/town> VIC <Customer state> 3149 <Customer postcode> <Customer email> lolly_deng0530@icloud.com VicTrack has been advised that you have placed an enquiry through the Dial Before You Dig service, with the following details. Please be advised on the response. Sequence Number

<Enquiry No> 86289840

Enquiry Date

<Enquiry date/time> 02/08/2019 15:41

Response

AFFECTED

Address

<Worksite Victoria Street Address> <Worksite suburb/town> Melbourne

Location in Road

<Worksite Road Location> CarriageWay,Footpath,Nature Strip

Activity

<Activity desc> Planning & Design

To obtain information and plans forward your enquiry to External.Property@VICTRACK.com.au. Include a brief description of your intended works. Please also see VicTrack's Network Protection Plan attachment. This protection plan must be adhered to. Information on VicTrack’s Permit To Work requirements and application form are to be accessed from https://www.victrack.com.au/i-want-to/permit-to-work. NB:The Cable details contained within this document and related attachments are valid for 14 days only. If you have any queries, please contact: Greg Peel on 0417 584 179, or David Boot on 0418 749 336, or Habib Dagher on 0488 226 700. Yours sincerely, Joe De Luca External Plant Manager

Vic Track’s disclaimer Please note that these Communication cable plans are only a guide and the drawings should not be scaled to locate the cable. No warranty is given that the information is accurate or complete. Note - VicTrack does not have responsibility for the signalling cables that may be in the area, information for signalling cables can be obtained from ARTC (call Mr Mick Stoneham 0417 219 191) for standard gauge line / V/line (call Mr David Dunstan 0403 195640) for country and V/Line corridors) / Metro (call Signal Fault centre on 9619 2999) of Metro for signalling cables in the suburban area).


Date: 02/08/2019 <Enquiry Date> Sequence No: 86289840 <Enquiry Number> <Worksite Victoria Street address> Melbourne <Worksite suburb/town>

Overview Map

1

<stripmap> LEGEND:

1 0 0.06km <stripmap scalebar>

Detail Map Area

Affected DBYD Work Area

Underground Fibre Optic Cable

VicTrack Rail Reserve

DISCLAIMER: This drawing has been prepared by, or compiled from information provided by persons other than VicTrack. To the maximum extent permissible by law, VicTrack takes no responsibility for, and makes no representations in relation to, completeness, accuracy or quality of any information contained in this drawing. Each user of this drawing releases VicTrack from all and any loss, damage, cost, expense or liability in relation to the use of, or any reliance on, this drawing or the information contained in it. All written dimensions take precedence over scaled dimensions. This drawing is provided only for the information of the person or organisation to whom VicTrack provided it. It may not be provided to, or used by, any other person without VicTrack's prior written consent. Exact positions of any assets shown on this map report should be confirmed on site. Any work being carried out within the Rail Reserve, contact External.Property@VICTRACK.com.au


Sequence No: Job No: Location:

86289847 16768212 Victoria Street, Melbourne, VIC 3000

Tile No: 1

Legend | Scale: 1:1500

Plans generated 02/ 08/ 2019 by Pelicancorp TicketAccess Software | www.pelicancorp.com

DISCLAIMER: While reasonable measures have been taken to ensure the accuracy of the information contained in this plan response, neither Primus Telecom or PelicanCorp shall have any liability whatsoever in relation to any loss, damage, cost or expense arising from the use of this plan response or the information contained in it or the completeness or accuracy of such information. Use of such information is subject to and constitutes acceptance of these terms. AU.Primus Telecom - Response Plan.docx (13 Dec 2018)


Sequence No: Job No: Location:

86289849 16768212 Victoria Street, Melbourne, VIC 3000

Tile No: 1

Legend | Scale: 1:1500

Plans generated 02/ 08/ 2019 by Pelicancorp TicketAccess Software | www.pelicancorp.com

DISCLAIMER: While reasonable measures have been taken to ensure the accuracy of the information contained in this plan response, neither AARNet or PelicanCorp shall have any liability whatsoever in relation to any loss, damage, cost or expense arising from the use of this plan response or the information contained in it or the completeness or accuracy of such information. Use of such information is subject to and constitutes acceptance of these terms. AU.AARNet - Response Plan.docx (29 June 2018)


Tile No: 1

Sequence Number: [Seq. no.] 86289841 DISCLAIMER: THIS DRAWING SHOULD NOT BE SCALED TO LOCATE CABLES. NO WARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE OR COMPLETE. IF YOU REQUIRE INFORMATION REGARDING LOCATING THE CABLE PLEASE CALL NEXTGEN. THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR DIAL BEFORE YOU DIG USE. THIS PLAN CONTAINS COMMERCIALLY SENSITIVE INFORMATION AND IS TO BE TREATED ACCORDINGLY. NO SUCH INFORMATION IS TO BE PASSED ONTO OTHER PARTIES WITHOUT WRITTEN CONSENT FROM NEXTGEN PTY LTD.

Date: [Date] 02/08/2019


Tile No: 1

SEQUENCE NUMBER: 86289852 JOB NUMBER: 16768212 ADDRESS: Victoria Street, Melbourne, VIC 3000

LEGEND

The Vocus Group includes related bodies corporate of Vocus Communications Limited ACN 084 115 499.

SCALE: 1:1000


Optus Contract Management Team Unit 9, 677 Springvale Road Mulgrave, Victoria, 3178

Date: To: Company: Address:

ENQUIRY DETAILS Location: Sequence No.: DBYD Reference:

02/08/2019 Miss Luolin Deng 6 Colebrook Avenue Mount Waverley, VIC 3149

Victoria Street, Melbourne, VIC 3000 86289844 16768212

In relation to your enquiry concerning the above location, Optus advises as follows: Optus records indicate that there ARE NO underground Optus FIBRE OPTIC TELECOMMUNICATIONS ASSETS in the vicinity of the above location as per the attached drawing(s). This reply is valid for a period of 30 days from the date above. IMPORTANT INFORMATION Asset location drawings provided by Optus are reference diagrams and are provided as a guide only. The completeness of the information in these drawings cannot be guaranteed. Exact ground cover and alignments cannot be provided with any certainty as these may have altered over time. Depths of telecommunications assets vary considerably as do alignments. It is essential to identify the location of any Optus assets in the vicinity prior to engaging in any works. DUTY OF CARE When working in the vicinity of telecommunications assets you have a legal “Duty of Care” and non-interference that must be observed. It is your responsibility as the requesting party (as a landowner or any other party involved in the planned works) to design for minimal impact to any existing Optus asset. Optus can assist at the design stage through consultation. It is also your, as the requesting party (or your representative’s), responsibility to: a)

Obtain location drawings (through the Dial Before You Dig process) of any existing Optus assets at a reasonable time before any planned works begin.

b)

Have an Optus Accredited Asset Locator identify the general location of the Optus asset and physically locate the asset where planned works may encroach on its alignment.

c)

Contact Optus for further advice where requested to do so by this letter.

Optus Dial Before You Dig Response – Negative V6

Page 1 of 3


DAMAGE TO ANY OPTUS NETWORK MUST BE REPORTED TO 1800 500 253 IMMEDIATELY You, your head contractor and any relevant subcontractor are all responsible for any Optus asset damage as a result of planned activities in the vicinity of Optus assets. This applies where works commence prior to obtaining Optus drawings, where there is failure to follow instructions or during any construction activities. Optus reserves the right to recover compensation for loss or damage to its assets including consequential loss. Also, you, your head contractor and any relevant subcontractor may also be liable for prosecution under the Criminal Code Act 1995 (Cth). ASSET RELOCATIONS You are not permitted by law to relocate, alter or interfere with any Optus asset under any circumstance. Any unauthorised interference with an Optus asset may lead to prosecution under the Criminal Code Act 1995 (Cth). Enquiries relating to the relocation of Optus assets must be referred to the relevant Optus Damages and Relocations Team (refer to “FURTHER ASSISTANCE”). APPROACH DISTANCES On receipt of Optus asset location drawings and prior to commencing any planned works near an Optus asset, engage an Optus Accredited Locator to undertake a general location of the Optus asset. Physical location of the Optus asset by an Optus Accredited Locator will also be required where planned works are within the following approach distances of the general location of the Optus asset: a) In built up metropolitan areas where road and footpaths are well defined by kerbs or other features a minimum clear distance of 1 meter must be maintained from the general location of the Optus asset. b) In non-established or unformed metropolitan areas, a minimum clear distance of 3 meters must be maintained from the general location of the Optus asset.

c)

In country or rural areas where wider variations may exist between the general and actual location of an Optus asset may exist, then a minimum clear distance of 5 meters must be maintained from the general location of the Optus asset.

If planned works are parallel to the Optus asset, then the Optus asset must be physically located by an Optus Accredited Locator at a minimum of 5 meter intervals along the length of the parallel works prior to work commencing.

Under no

circumstances is crossing of any Optus asset permitted without physical location of the asset being carried out by an Optus Accredited Locator. Depending on the asset involved an Optus representative may be required onsite. The minimum clearances to the physical location of Optus assets for the following specific types of works must be maintained at all times. Note: Where the clearances in the following table cannot be maintained or where the type of work differs from those listed then advice must be sought from the relevant Optus Damages and Relocations Team (refer to “FURTHER ASSISTANCE”). Type of Works

Clearance to Physical Location of Optus Asset

Jackhammers / Pneumatic Breakers

Not within 1 meter.

Light duty Vibrating Plate or Wacker Packer type compactors (not heavy road construction vibrating rollers etc.)

500mm compact clearance cover before a light duty compactor can be used over any Optus conduit.

Boring Equipment (in-line, horizontal and vertical)

Not within 5 meters parallel of the Optus asset location without an Accredited Optus Asset Locator physically exposing the Optus asset and with an Optus representative onsite.

No compaction permitted over Optus direct buried cable without prior approval from Optus.

Optus Dial Before You Dig Response – Negative V6

Page 2 of 3


Type of Works

Clearance to Physical Location of Optus Asset Not to cross the Optus asset without an Accredited Optus Asset Locator physically exposing the Optus asset and with an Optus representative onsite.

Heavy vehicle Traffic (over 3 tonnes)

Not to be driven across Optus conduits with less than 600mm of cover. Not to be driven across Optus direct buried cable with less than 1.2 meters of cover. Once off crossings permitted, multiple crossing (e.g. road construction or logging) will require Optus approval. Accredited Optus Asset Locator to physically expose the Optus asset to verify actual depth.

Mechanical Excavators, Farm Ploughing, Vertical Hole installation for water bore or fencing etc.

Not within 1 meter. Accredited Optus Asset Locator to physically expose the Optus asset to verify actual location.

ASSET CLEARANCES AFTER COMPLETION OF WORKS All Optus pits and manholes must be a minimum of 1 meter from the back of any kerb, 3.5 meters of the road surface without a kerb or not within 15 meters of street intersection. In urban areas Optus conduit must have the following minimum depth of cover: •

Footway

600mm;

Roadway

1 meter at drain invert and at road centre crown.

In rural areas Optus conduit must have a minimum depth of cover of 1 meter and direct buried cable 1200mm. In cases where it is considered that the above clearances cannot be maintained at the completion of works, advice must be sought from the relevant Optus Damages and Relocations Team (refer “Further Assistance”). FURTHER ASSISTANCE Further assistance on asset clearances, protection works or relocation requirements can be obtained by contacting the relevant Optus Damages and Relocations Team on the following email address: NFODamages&RelocationsDropbox@optus.com.au Further assistance relating to asset location drawings etc. can be obtained by contacting the Optus Network Operations Asset Analysis Team on 1800 505 777. OPTUS ENGINEERING DRAWING SYMBOLS

Optus Dial Before You Dig Response – Negative V6

Page 3 of 3


WARNING: This document is confidential and may also be privileged. Confidentiality nor privilege is not waived or destroyed by virtue of it being transmitted to an incorrect addressee. Unauthorised use of the contents is therefore strictly prohibited. Any information contained in this document that has been extracted from our records is believed to be accurate, but no responsibility is assumed for any error or omission. Optus Plans and information supplied are valid for 30 days from the date of issue. If this timeline has elapsed please raise a new enquiry. Sequence Number:

Date Generated:

86289844 For all Optus DBYD plan enquiries – Email: Fibre.Locations@optus.net.au For urgent onsite assistance contact 1800 505 777 Optus Limited ACN 052 833 208

02/08/2019


802 x 608mm

GENERAL BORING NOTES (Version 2.1) :

GENERAL BORING NOTES (Version 2.1) CONTINUED:

BORING INCLUDES, BUT IS NOT LIMITED TO, DIRECTIONAL DRILLING, LASER BORING, MICRO-TUNNELLING, PIPE JACKING, AND OTHER TRENCHLESS TECHNOLOGY METHODS.

THE CONTRACTOR SHALL COMPLY WITH THE REQUIREMENTS OF ALL EXISTING SERVICES PROVIDERS RELATED TO INSTALLATION OF NEW SERVICES IN THEIR VICINITY.

THE CONTRACTOR SHALL HAVE THE APPROPRIATE EXPERIENCE TO UNDERTAKE THE TRENCHLESS CONSTRUCTION WORKS.

WHEN A SERVICE AUTHORITY REQUESTS THAT A REPRESENTATIVE BE PRESENT ON-SITE WHEN THE WORKS ARE TO BE EXECUTED IT IS THE CONTRACTORS

A GEOTECHNICAL SITE INVESTIGATION SHALL BE PERFORMED TO IDENTIFY THE SUBGROUND PROPERTIES IN THE PROJECT AREA AND ASSIST IN THE DESIGN.

RESPONSIBILITY TO NOTIFY AND MAKE THE NECESSARY ARRANGEMENTS.

THE GEOTECHNICAL REPORT SHALL INCLUDE THE SPECIFIC SOIL CHARACTERISTICS IN RELATION TO THE USE OF THE TRENCHLESS CONSTRUCTION TECHNIQUE.

THE DESIGN DRAWINGS ARE BASED ON HISTORICAL DATA PROVIDED BY SERVICE PROVIDERS WHICH MAY NOT BE CURRENT AND MAY NOT SHOW ALL THE SERVICES IN

THE CONTRACTOR SHALL INSTALL A NON-CONDUCTIVE CASING COMPLYING WITH POWERCOR / CITIPOWER REQUIREMENTS OF SUITABLE STRENGTH TO WITHSTAND THE

THE AREA AND THEIR CORRECT POSITION.

EXPECTED TENSILE LOADS FROM INSTALLATION AND GROUND AND SURCHARGE LOADS BASED ON THE EXISTING GEOTECHNICAL CONDITIONS.

IT IS THE CONTRACTORS RESPONSIBILITY TO PROVE ON-SITE ALL EXISTING SERVICE LOCATIONS AND DEPTHS AND TO PRODUCE A DETAILED EXISTING SERVICES

THE STABILITY OF THE BORE HAS TO BE MAINTAINED AT ALL TIMES DURING THE DRILLING PROCESS, INSTALLATION OF CASINGS, INSTALLATION OF CONDUITS, CABLES,

PLAN.

AND PIPES, AND DURING SERVICE.

THIS PLAN SHALL INCLUDE, BUT NOT LIMITED TO, AN OVERALL PLAN, CROSS SECTION(S), AND A LONGITUDINAL SECTION SHOWING THE PROPOSED BORE ALIGNMENT

DRILLING MUD AND / OR BACKFILL OF THE ANNULUS AROUND THE CASING OR ANY BACKFILL OF THE EXCAVATED HOLE HAS TO HAVE NON-SHRINKING PROPERTIES.

INCLUDING CALCULATED OFFSETS WITH RESPECT TO THE EXISTING SERVICES. ALL PLANS ARE TO BE TO SCALE IN ACCORDANCE WITH CITIPOWER’S REQUIREMENTS.

PRIOR TO COMMENCEMENT OF THE WORKS, THE CONTRACTOR SHALL SUBMIT A DETAILED WORK METHOD STATEMENT TO CITIPOWER INCLUDING A DETAILED

AS PART OF PRODUCING THIS PLAN THE CONTRACTOR SHALL CONFIRM WITH THE RELEVANT SERVICE AUTHORITIES THEIR MINIMUM CLEARANCES REQUIRED TO THEIR

CONSTRUCTION METHODOLOGY WHICH INCLUDES, BUT IS NOT LIMITED TO, THE FOLLOWING:

SERVICE. NO PART OF THE BORED EXCAVATION SHALL ENCROACH INTO THE MINIMUM CLEARANCE NOMINATED. UNLESS OTHERWISE VARIED BY THE SERVICE PROVIDER

METHODS AND PROCEDURES TO IDENTIFY, LOCATE, AND CONFIRM DEPTH ON ALL EXISTING SERVICES IN THE WORKS AREA;

A 1 METRE MINIMUM CLEARANCE TO EXISTING SERVICES IS TO BE PROVIDED.

METHODS AND PROCEDURES FOR TRAFFIC AND EXISTING SERVICES MANAGEMENT;

THIS BORE PLAN SHALL BE SUBMITTED TO CITIPOWER FOR REVIEW.

LIST THE REQUIRED WORK PERMITS FROM THE RELEVANT AUTHORITIES PRIOR TO COMMENCEMENT OF THE WORKS;

CITIPOWER MAY RE-ISSUE THE DETAIL DESIGN DRAWINGS INCORPORATING THIS INFORMATION.

PROPOSED METHOD OF EXECUTION OF THE WORKS INCLUDING MONITORING PROGRESS OF THE BORE WITH RESPECT TO THE PROPOSED ALIGNMENT AND DEPTH,

UPON COMPLETION OF THE WORKS THE CONTRACTOR SHALL SUBMIT AS-BUILT INFORMATION TO CITIPOWER INCLUDING FINAL ALIGNMENT PLANS AND A BORE LOG

PROPOSED EMERGENCY / CONTINGENCY PLANS, AND COMPLIANCE WITH ENVIRONMENTAL AND OH&S REGULATIONS AND STANDARDS. AT THE TENDERING STAGE ALL

SHALL BE PRODUCED CONFIRMING FINAL DEPTH OF CONDUITS SHOWING UPPER AND LOWER LIMITS OF THE ’AS BUILT’ BORE.

CONTRACTORS SHALL PROVIDE A SAMPLE WORKS METHOD STATEMENT FOR REVIEW.

THE CONTRACTOR SHALL SUBMIT TO CITIPOWER / POWERCOR ALL DAILY RECORDS, INCLUDING PARAMETERS / SPECIFICATION OF DRILLING PARAMETERS,FOR

REFER TO TYPICAL TRENCH DETAIL

THERMAL CONTROL BACKFILL MATERIAL 100

300

100

1200

HVLV

KL

LV

LVABC

NEWCOND

NHV

NHVABC

NHVLV

NHVUG

NLV

NLVABC

NLVMUG

NLVSUG

NPL

NPLC

NSCUG

OBST

PL

RHV

RLV

RPL

MI N 1200

LAYERS

-JOINT HOLE LOCATIONS -BACKFILL SPECIFICATIONS THE U/G CABLE PLAN SHALL INCLUDE BUT NOT BE LIMITED TO INCLUDING THESE DETAILS

FINAL BORE ALIGNMENT/DEPTH SHALL BE DETERMINED FROM THE GEOTECHNICAL INVESTIGATION AND THE BORE REPORT

REFER TO TYPICAL TRENCH DETAIL

BORE CONSTRUCTION PIT

BORE CONSTRUCTION PIT

(LOCATION TO BE CONFIRMED)

(LOCATION TO BE CONFIRMED) BH1

500 CLEARANCE ZONES

- EXACT LOCATION OF BORE HOLES, JOINT HOLES, COMMS PITS AND CABLE SHEATH BOND

BH3

SYSTEM NEED TO BE DEVELOPED. - ALL AVAILABLE DETAILS OF CITIPOWER AND OTHER AUTHORITIES’ EXISTING ASSETS

BH2

ARE TO BE OBTAINED FROM MOCS (DIAL 1100) PRIOR TO ANY EXCAVATION. NOTE:ALL REASONABLE CARE HAS BEEN TAKEN TO ENSURE THAT THE U/G ASSET INFORMATION IS CORRECTLY SHOWN ON THE TENDER PLAN. HOWEVER THE

SECTIONAL VIEW - VICROADS DECLARED ROAD CROSSING

27 83 27 . 0 8. 40 W A 27 BU TER 9. S 65 ST VA TR OP LV EE SI E GN

VMW 153 SUPV CABLE - APPROX 1.20 COVER

APPROX 15.20

VM-WA No2 66kV CABLE - APPROX 1.20 COVER

APPROX 14.80

VMW 152 SUPV CABLE - UNKNOWN COVER

APPROX 14.70

VM-WA No1 66kV CABLE - APPROX 1.20 COVER

WORK WITHIN 500mm OF ELECTRICAL ASSETS IS PROPOSED, THE POSITION OF THE ASSETS MUST FIRST BE CONFIRMED BY CAREFUL HAND EXCAVATION. - THE EXCAVATION WORK CANNOT COMMENCE UNTIL APPROVAL CONSENT IS OBTAINED FROM APPROPRIATE AUTHORITIES (COUNCIL, VIC ROADS....) AND CITIPOWER. - WARNING:IF TRENCHING ADJACENT TO STRUCTURES (i.e... POLES, ROAD SIGNS, ETC.), IT IS THE CONTRACTORS RESPONSIBILITY TO ENSURE THAT THEY ARE SUFFICIENTLY PROPPED/SECURED TO PREVENT MOVEMENT AND DAMAGE ITEM TRENCH

1300m

BORE

AS REQ

CONDUIT

350176

AS REQ

CONDUIT

350181

AS REQ

MEDIAN KL

29 4. 40

APPROX 5.45 APPROX 4.50

CO VE R 0. 75

3.75

SOUTH WEST KL

APPROX 1.95 APPROX 1.70 APPROX 0.95-1.40

TELSTRA - UNKNOWN COVER HV & P/L CABLES - UNKNOWN COVER

APPROX 0.90 APPROX 0.50-0.80

DATUM SOUTH WEST BL

F

CO VE R

0.00

HV & SUPV CABLES - UNKNOWN COVER

CO VE R N

S E L B A VC k 6 6

W

3x

T XAC S-E E L B D E A N MI VC k R 6 E 6 T E D E B O RT VE O C - WHEN CROSSING EXISTING 66kV CABLES

REFERENCE

T

CO VE R

0. 30 T

CO VE R

R U S S E L LS T R E E T

CONTI NUED ON CP9/4924/6

T

UN KN OW

AT ER

UN KN OW

N

VA LV ES

T

22 5. 20

T

UN K TR NOW A N UN FF PI KN I C T OW PO 21 8. L N E PI 21 90 T 20 21 9. 9. 20

UN KN OW

N

LINKING:

SAP NETWORK No.

5057043

MELWAY MAP REFERENCE

2B D10 - 2F F2

CABLE PLAN No.

MCC 66, 67, 72, 73, 1180, 1181

OPERATION DIAGRAM

BQ, W

SUBSTATION NAME

BQ, W

SUBSTATION DRAWING

-

OVERHEAD DRAWING

-

PROJECT MANAGER

KRIS AMATO

MIN 300mm SEPARATION REQUIRED FOR 1 . 65 CO VE R

PH: INSPECTOR

DAMIEN HARRIS PH:

CUSTOMER CONTACT

PRIOR TO COMMENCEMENT OF CONSTRUCTION

PIT 268 SOI L

48 HOURS MINIMUM PRIOR NOTICE SHALL BE GIVEN TO ARRANGE FOR AN A.P.A. PIPELINE INSPECTOR

GIVEN TO ARRANGE FOR ONSITE INSPECTION REQUIRED BY OPTUS

FOR TENDER PURPOSES ONLY

CONTACT CAN BE MADE ON 1800 505 777

TREE 333. 30 TREE 332. 40

POLE ( 87458)342. 30

TREE 343. 40 ELECTRI CAL PI T 342. 60

UNKNOWN PI T 343. 90 WATER VALVE 343. 80

UNKNOWN PI T 345. 00

TREE 348. 70 UNKNOWN COVER

T

48 HOURS MINIMUM PRIOR NOTICE SHALL BE

DRI VE WAY 355. 90

DRI VE WAY 359. 60

TREE 362. 20 TELSTRA PI T 362. 10

FI RE HYDRANT 365. 50

WATER VALVE 371 . 90

TELSTRA PI T 372. 40

TREE 374. 40 WATER VALVE 373. 10 WATER VALVE 372. 90

WATER VALVE 374. 60

WATER VALVE 380. 40

UNKNOWN PI T 381 . 60 DRAI NAGE PI T 381 . 50

TREE 388. 10

ELECTRI CAL PI T 381 . 70 POLE ( 771849)381 . 70

PROXIMITY TO EXCAVATION AREA

WATER VALVE 393. 20

TREE 394. 50

PI T 268 395. 00

GAS VALVE 398. 40

GAS VALVE 398. 90

TREE 405. 70

DRAI NAGE PI T 410. 50

TREE 418. 10

POLE ( 87515)424. 10

UNKNOWN PI T 428. 30

TREE 430. 00

TREE 447. 80

DRAI NAGE PI T 460. 90

POLE ( 88054)463. 70

MAJOR OPTUS CABLES EXIST IN CLOSE

DRAI NAGE PI T 472. 50 TREE 471 . 90

POLE ( 88200)472. 60

CONTACT CAN BE MADE ON 9463 8254

CP1/22 SERIES

SOIL TEST REFERENCE No.

-

SOIL CLASSIFICATION

-

SOIL TO BE REUSED

-

F CitiPower Pty ACN 064 651 056 35 Rooney Street Burnley Vic 3121 POSTAL ADDRESS

Telephone (03) 9297 8900

Locked Bag 14031

Facsimile

EXISTING HV

NEW HV

HV

EXISTING LV MAINS

NEW LV MAINS

LV

GENERAL

EXISTING HV

NHV

NEW HV

EXISTING LV

NLV

NEW LV

EXISTING LV SERVICE

NEW LV SERVICE

HVABC

EXISTING HV ABC

NHVABC

NEW HV ABC

EXISTING PL EXISTING SUPERVISORY

NEW PL NEW SUPERVISORY

LVABC

EXISTING LV ABC

NLVABC

NEW LV ABC

P

POLE SUBSTATION

STRAIGHT THROUGH JOINT

CURRENT REVISION 25/6/12 A

RECEIVED FROM FOLLOWING:

BUILDING LINE

SUBTRANS POLE

LV MAINS TEE JOINT

ROAD SERVICE PIT

KL

KERB LINE

HV/LV POLE

LV SERVICE TEE JOINT

NEW CONDUIT

HV CABLE TERMINATION

HV POLE

INSULATED END

EXISTING CONDUIT PP

PL HVLV

EXISTING PL EXISTING HV/LV

RHV

REMOVE HV

RLV

REMOVE LV

NPL

NEW PL

NHVLV

NEW HV/LV

RPL

REMOVE PL

LV CABLE TERMINATION

LV POLE

PUBLIC LIGHTING POLE BRACKET AND LUMINAIRE

AERIAL STAY

PUBLIC LIGHTING BRACKET AND LUMINAIRE

GROUND STAY

SEALED END CUT CABLE END REMOVE POLE

PARALLELING PILLAR

SITE AND MOCS INFORMATION CHECKED AND UPDATED

CP9/4924/5A SHEET 6 OF 8

CONFIRMATION OF OBSTRUCTIONS

SERVICE PIT

BL

(03) 9297 6350

Melbourne Mail Centre Vic 8001

F G H J K OH CONDUCTORS

-

INSTALLATION NOTES

A B C D E

UG CABLES

1300 301 101 -

PH:

CAUTION MAJOR OPTUS CABLES IN AREA

9683 4140

NEW CONDUITS.

THE PRESENCE OF AN A.P.A. PIPELINE INSPECTOR

LEGEND

UNIT

APPROX ROUTE LENGTH ’BQ - W’

HAND EXCAVATED PROVING MUST BE CARRIED OUT IN

Ci ti POW ER Pty - AutoCAD U/G B1

SAP No.

APPROX 7.00

MI N

T

DESCRIPTION

APPROX 8.10

TR EE

26 0. 65

26 9. 40 26 TR 9. EE 90 TR EE

APPROX 15.50

13.60

28 28 8. 8865 T 28 . 0 RE 8. 90 TRE E TR E EE

TR EE 26 2. 60 26 PO 3. LE 90 ( 87 UN 51 KN 4) OW N PI T

25 2. 05

LY GO N ST RE ET T

INFORMATION CAN NOT BE GUARANTEED TO BE CORRECT OR COMPLETE. WHERE

31 . 00 27 SCALE 1:250 . 25 AP E MIN 1200 COVER UNDER ROAD SURFACE 1 PR AS 6. 65 OX T BL CONTRACTOR TO PROVE ALL DEPTHS ON SITE AND VERIFY ALL EA 1 3. ST 50 AP CLEARANCES WITH THE RELEVANT AUTHORITIES PRIOR TO CONSTRUCTION KL ME 1 3. PR DI 25 OX AN VI 4. KL CT 00 RA AP M CK ED 2. PR 55 I CO AN OX MM KL 1 . 40 S CA W 0. BL E ST 00 E KL UN KN DA OW TU N M CO W VE 30.55 NORTH EAST BL ES R T ED UN 26.85 NORTH EAST KL GE KN FO OW OT 17.60 MEDIAN KL N PA CO VE TH APPROX 15.60 W-WA 66kV CABLE - APPROX 1.20 COVER R

TR EE

VI CT OR I A

500 CLEARANCE ZONE

NOTES:

APPROX 50m BORE

M N RE I FE 1. 20 R TO COV SE ER CT I ON

T

LYGON STREET

1000 CLEARANCE ZONE

BH3

CONTACT CAN BE MADE ON 9632 9945

EXISTING DC

TEMP

TYPICAL TRENCH DETAIL

NOTES :

BH2

TO ARRANGE FOR ONSITE INSPECTION REQUIRED

DC

SHADE

GROUND

REFER NOTE 1 BELOW

(N) 6xł150 AND 4xł63 HD PVC

W ES T BL

ST RE ET

0. 75 MI N

HVABC

NOT TO SCALE

PIT 551

TE TE LST PI T LS RA 55 T G PI 120 T PO AS RA 4. P I UN LE VA T 205 00 . L 2 ( 50 K UN NO 825 VE 05. 43 20 50 W K UN NO N P )2 5. W K T 06 90 UN NO N I 40 PI 206 . W K T UN NO N . 4 2 P 5 KN W 0 I OW N P T 2 6. 60 GA I T 06. N UN PI 20 70 S T KN VA 20 7. 60 OW LV 8. 40 E N PI 208 T SE 80 21 . W 0. ER 40 PI T 21 3. 90

HV

-EARTHING CONNECTION DETAILS

REFER TO GENERAL BORING NOTES FOR DETAILS

MACKENZI E

CO VE R

T

W A DR TER UN AI NA VAL K TE NO GE VE 1 UN LST W N PI T 968 KN RA PI 19 . TE O T 80 0 19 . 0 UN LS W N PI T 9 1 . 20 TR KN TRA PI T 99. OW A 40 2 PO FF N PI T 0 LE I C PI 20 0. 10 P T ( 85 OL 20 1. 50 45 E 2 1. 6) 01 60 BL 20 . 80 20 2. 20 3. 60

ESCUG

-SELECTION OF 66kV CABLES, FIBRE OPTIC CABLES AND EARTH CABLES

NOT TO SCALE

LYGON STREET

(LOCATION TO BE CONFIRMED)

CAUTION A.P.A. GAS PIPELINE IN AREA

EQUIP

VICTORIA STREET

BORE CONSTRUCTION PIT

AP PR OX

EPLC

- THE SUCCESSFUL TENDER SHALL DEVELOP THE FOLLOWING DETAILS:

BORE HOLES TO BE GROUTED WITHIN 24hrs OF CONDUIT INSTALLATION

REFER TO SECTIONAL VIEW

BH1

BY TELSTRA

ELVSUG

MI N 750

29 . 90 26 . 55 AP EA PR 1 5 ST . OX 1 0 BL EA 1 3. ST 75 AP KL ME 1 3. PR DI 70 OX A AP N VI 9. PR KL CT 35 OX R AP A M C 8. ED P K 35 I CO AN AP ROX SE MM PR 6. K W L 85 S OX ER CA 4. BL 40 UN E AP KN 3. PR UN OW 8 OX 0 KN AP N W OW CO 2. PR A 3 T VE N OX 0 ER AP CO R W 2. PR ES VE 3 U OX 0 T N R KN KL 0. OW 75 N CO 0. 00 VE R

4 UN xCO KN ND OW UI N TS CO VE R

48 HOURS MINIMUM PRIOR NOTICE SHALL BE GIVEN

ELVMUG

MARKER TAPE

(LOCATION TO BE CONFIRMED)

PROXIMITY TO EXCAVATION AREA

FOR 66kV CABLES

TYPICAL BORE DETAIL

PROPOSED DRILLING PROFILE

AND CONFIRMED TO ACHIEVE REQUIRED RATING.

MAJOR TELSTRA CABLES EXIST IN CLOSE

EHVUG

- REINSTATE CONDUIT ROUTE FOR 66kV CABLES

MI N 0. 75 COVER

CP 9/ 49 24 /4 ON

CO NT I NU ED

CAUTION MAJOR TELSTRA CABLES IN AREA

DC

- EXCAVATE AND INSTALL NEW CONDUITS AS SHOWN (GA211)

GROUND LEVEL

BORE CONSTRUCTION PIT

BA UN NNE KN RP OW OL E N PO PI 175 LE T 00 17 . ( 80 5. 8 1 BA 41 0 )1 NN 77 ER . 50 PO LE T 17 9. UN ELS 50 KN TR OW A P BA I N T NN PI 18 T ER 18 2. 10 PO 2. 90 LE BA 18 TR NN VI 3. 50 EE CR ER OA 18 PO 5. SP DS L EE EL E 18 60 D 7 E . 5 SI C 1 GN 87 0 . 8 0 BA NN ER PO LE 19 1. 50

CONTACT CAN BE MADE ON 0407 899 159

COND

OF THE LOCAL AUTHORITIES AND VICROADS

PROXIMITY TO EXCAVATION AREA

REQUIRED BY AAPT

BL

REINSTATE PAVEMENT TO THE SATISFACTION

MAJOR AAPT CABLES EXIST IN CLOSE

GIVEN TO ARRANGE FOR ONSITE INSPECTION

~7m

PROGRESS AND ANY ADDITIONAL MEASURED DRILLING MACHINE PARAMETERS (REFER TO DETAILED NOTES).

T

48 HOURS MINIMUM PRIOR NOTICE SHALL BE

7

WORK REQUIRED

~3m BELOW INVERT OF THE

1. THESE FIGURES ARE NOMINAL ONLY. FIGURES NEED TO BE CHECKED

E

5

ANNULUS TO BE FILLED WITH

INSTANCE MUD OR LUBRICANT USED, PUMPING / JACKING PRESSURE, PUMPING / JACKING RATE, TORQUE, ROTATION, LOCATION OF DRILLING HEAD, THRUST, DRILLING

DA TU M

CAUTION MAJOR AAPT CABLES IN AREA

~10m

APPROX 5800

E

BH2

( E)4xCONDUI TS - UNKNOWN COVER

W ES T BL

~7m

STREET

DA TU M

BH1

OPTUS - UNKNOWN COVER

GIVEN THAT ALL EXISTING SERVICES ARE SHOWN.

3

NON-SHRINKING BACKFILL

MI N 750

SHOULD BE PROVEN ON SITE. NO GUARANTEE IS

2

SLEEVE

BORE HOLE DEPTH TO BE

750 MI N

APPROXIMATE ONLY AND THEIR EXACT POSITION

MIN 1500

DEPTH

BORE HOLE No.

BH3

100 MI N

THE LOCATIONS OF UNDERGROUND SERVICES ARE

DETERMINED ON SITE

300

BEWARE OF UNDERGROUND SERVICES

BORE HOLE LOCATION INDICATIVE ONLY, FINAL LOCATIONS TO BE

450 MI N

WARNING

1

GROUND LEVEL

23 06 23 . 0 0. G 23 70 AS 2. P 23 40 OLE VAL 3. 35 UNK ( 8 VE UN NO 675 23 KN W N 4) 23 4. 1 OW PI 4. 0 B T N 23 90 L PI 5 U T NK 23 . 10 23 5. 55 POL NOW 23 6. TR E N 1 0 P 88 23 6. W AF ( 4 T 05 I A 0 F 6 23 . 8) C 75 UN TE I P R 6 23 . 90 SE KNO VA OL 8. W LV E 30 PI E W TELLA R P N PI E T T LS R I TR A PI T

29 . 90 26 . 5 AP 5 EA PR 1 5. ST OX 1 0 BL EA 1 3. ST 75 AP KL ME 1 PR 3. DI 70 OX A AP N VI 1 0. P KL CT 85 R AP ROX A M CK PR 6. ED 20 OX I CO AN S MM 4. EW KL 40 S ER AP CA 3. PR BL U 8 OX 0 NK E AP W N 2. PR UN AT OW 30 O KN E AP N X R W OW C 2. PR ES OV 25 UN N OX T E KN CO R KL 0. VE O 70 W R N C 0. OV 00 ER

0

(REFER INSTALLATION NOTE 3)

APPROVED IN PRINCIPLE CitPower Rep:T.PHAN

Date:12/07/12

66 kV CBD SECURITY PROJECT STAGE 2 PROPOSED CONDUIT ROUTE PLAN BQ-W, MELBOURNE

Gas

Y

Water

Y

Telstra

Y

Optus

Y

Sewer

Y

Drain

Y

CHECKED APPROVED

PTC

Y

PMA

N

VicRoads

N

DRAWN

DO (SKM) MJC (SKM)

CV (SKM)

30/09/09 13/10/09

19/10/09

2.5

0

2.5

5.0

7.5

10.0

12.5

LENGTHS ARE IN METRES

SCALE 1: 250 B1


REINSTATE PAVEMENT TO THE SATISFACTION OF THE LOCAL AUTHORITIES AND VICROADS

WARNING

PLEASE NOTE

BEWARE OF UNDERGROUND SERVICES

PUBLIC TRANSPORT SERVICES WILL BE

COMPACTED CRUSHED ROCK (REFER BACKFILL SPECIFICATION)

AFFECTED IN THE VICINITY OF WORKS.

THE LOCATIONS OF UNDERGROUND SERVICES ARE

MARKER TAPE

APPROX 15.60

W-WA 66kV CABLE - APPROX 1.20 COVER

APPROX 15.50

VMW 153 SUPV CABLE - APPROX 1.20 COVER

APPROX 15.20

VM-WA No2 66kV CABLE - APPROX 1.20 COVER

APPROX 14.80

VMW 152 SUPV CABLE - UNKNOWN COVER

APPROX 14.70

VM-WA No1 66kV CABLE - APPROX 1.20 COVER

APPROXIMATE ONLY AND THEIR EXACT POSITION

GROUND LEVEL

LAYERS

466 x 343 0

1

2

3

5

7

BL

COND

DC

EHVUG

ELVMUG

ELVSUG

EPLC

EQUIP

ESCUG

HV

HVABC

HVLV

KL

LV

LVABC

NEWCOND

NHV

NHVABC

NHVLV

NHVUG

NLV

NLVABC

NLVMUG

NLVSUG

NPL

NPLC

NSCUG

OBST

PL

RHV

RLV

RPL

APPROX 8.10

SHOULD BE PROVEN ON SITE. NO GUARANTEE IS

SHADE

TEMP

APPROX 5.45

GIVEN THAT ALL EXISTING SERVICES ARE SHOWN.

APPROX 4.30

750 MI N

3.75

WORK REQUIRED

DRAIN - UNKNOWN COVER WEST KL

- EXCAVATE TRIAL HOLES AS SHOWN

APPROX 1.95

- PROVE OFFSET AND COVER OF EXISTING ASSETS

APPROX 1.40

P/L CABLES - UNKNOWN COVER

APPROX 1.10

P/L CABLES - UNKNOWN COVER

- REINSTATE EXCAVATED HOLES

APPROX 0.50-0.90

100 MI N

SOFT SIEVED SAND

0.00

HV & SUPV CABLES - UNKNOWN COVER

APPROVED IN PRINCIPLE

DATUM WEST BL

(REFER TO CP1/23B)

CitPower Rep:T.PHAN

100 MI N

300

Date:30-10-09

1200

TYPICAL TRENCH DETAIL NOT TO SCALE (N) 6xł150 AND 4xł63 HD PVC

AP PR OX

4. 00 AP 2. PR 50 OX 1 . 40 0. 00

W ES T KL DA TU M

LY GO N ST RE ET

NOTE- TO ARRANGE FIELD NOTE RECORDING, CONTACT DAVID OATES FROM SKM ON 0416 430807. PLEASE GIVE MINIMUM 48 HOURS NOTICE. NOTE- WARNING:IF TRENCHING ADJACENT TO STRUCTURES (i.e... POLES, ROAD SIGNS, ETC.), IT IS THE CONTRACTORS

W ES T ED GE FO OT PA TH

RESPONSIBILITY TO ENSURE THAT THEY ARE SUFFICIENTLY PROPPED/SECURED TO PREVENT MOVEMENT AND DAMAGE

SE L B A C V R k 6 6 VE O C m 2 . X1 O R P AP

ITEM

DESCRIPTION

SAP No. UNIT

TRENCH

T

(N) TRIAL HOLE

MI N 0. 75 COVER

200 MI N

APPROX 1.00

- PRIOR TO WORKS ELECTRONICALLY LOCATE CABLES TO ENSURE TRIAL HOLE IS IN CORRECT LOCATION - EXCAVATE AND PROVE OFFSET AND COVER OF EXISTING

4.3m

R U S S E L LS T R E E T

ASSETS TO DETERMINE SUITABLE ROUTE FOR NEW CONDUITS MIN 300mm SEPARATION REQUIRED TO NEW CONDUITS

FR OM

LINKING:

KL TO CL TR I AL HO LE

REFERENCE

UN KN OW

N

T

CO VE R

1 . 5m

SAP NETWORK No.

5057043

MELWAY MAP REFERENCE

2B F12

CABLE PLAN No.

MCC 67, 72, 73

OPERATION DIAGRAM

W, VM

SUBSTATION NAME

-

SUBSTATION DRAWING

-

OVERHEAD DRAWING

-

PROJECT MANAGER

KRIS AMATO PH: 9683 4140

EXISTING LV MAINS

NEW LV MAINS

EXISTING LV SERVICE

NEW LV SERVICE

EXISTING PL EXISTING SUPERVISORY DC

EXISTING DC

NEW PL NEW SUPERVISORY

HV LV HVABC LVABC

EXISTING HV EXISTING LV EXISTING HV ABC EXISTING LV ABC

NHV NLV NHVABC NLVABC

NEW LV

P

POLE SUBSTATION

STRAIGHT THROUGH JOINT

SERVICE PIT

BL KL

BUILDING LINE

SUBTRANS POLE

LV MAINS TEE JOINT

ROAD SERVICE PIT

KERB LINE

HV/LV POLE

LV SERVICE TEE JOINT

NEW CONDUIT

HV CABLE TERMINATION

HV POLE

INSULATED END

EXISTING CONDUIT

NEW HV ABC NEW LV ABC

PP

PL HVLV RHV RLV

EXISTING PL EXISTING HV/LV REMOVE HV REMOVE LV

NPL

NEW PL

NHVLV

NEW HV/LV

RPL

REMOVE PL

PH: INSTALLATION NOTES

-

REFERENCE No.

-

SOIL CLASSIFICATION

-

SOIL TO BE REUSED

-

CitiPower Pty ACN 064 651 056

POSTAL ADDRESS

Telephone (03) 9297 8900

Locked Bag 14031

Facsimile

(03) 9297 6350

Melbourne Mail Centre Vic 8001

GENERAL NEW HV

-

Burnley Vic 3121

OH CONDUCTORS NEW HV

CUSTOMER CONTACT

35 Rooney Street

CONFIRMATION OF OBSTRUCTIONS RECEIVED FROM FOLLOWING:

EXISTING HV

DAMIEN HARRIS PH: 1300 301 101

SOI L

00 DATUM NORTH BL 0.

ELECTRI CAL PI T 118. 20 POLE ( 771849)118. 20 DRAI NAGE PI T 118. 00

UNKNOW N COVER

T

TREE 124. 60

TREE 127. 70

W ATER VALVE 129. 70

TREE 131 . 00

PI T 268 131 . 50

TREE 131 . 90

GAS VALVE 134. 90

GAS VALVE 135. 40

TREE 137. 20

( N)TRI AL HOLE APPROX 139. 20

TREE 141 . 80

TREE 142. 20

( N)TRI AL HOLE APPROX 145. 10

DRAI NAGE PI T 147. 00

BUS STOP SI GN 148. 40

W ATER VALVE 149. 70

TREE 154. 60 UG CABLES

LEGEND

Ci ti POW ER Pty - AutoCAD U/G A2

TREE 156. 80

PIT 268

LA TROBE STREET

INSPECTOR

LV CABLE TERMINATION PUBLIC LIGHTING POLE BRACKET AND LUMINAIRE PUBLIC LIGHTING BRACKET AND LUMINAIRE

LV POLE AERIAL STAY GROUND STAY

SEALED END CUT CABLE END REMOVE POLE

PARALLELING PILLAR

(REFER INSTALLATION NOTE 3)

CURRENT REVISION

-

A B C D E

CP9/4931 SHEET 1 OF 3

F G H J K

Gas

Y

Water

Y

Telstra

Y

Optus

Y

Sewer

Y

Drain

Y

DRAWN

PTC

N

CHECKED

PMA

N

APPROVED

VicRoads

N

LYGON & RUSSELL STS, MELBOURNE U/G CONSTRUCTION PLAN TRIAL HOLE FOR BQ-W 66kV - STAGE 2 DO (SKM) 22/10/09 NK (SKM)

MJC (SKM)

26/10/09

29/10/09

1.0

0

1.0

2.0

3.0

LENGTHS ARE IN METRES

SCALE 1: 100 A2