GW-IMP-WEB-1-S Count Pulse Datalogger MODBUS RTU

Page 1

MarCom

Datalogger web pulses counter Code: GW-IMP-WEB-1-S Version 6 inputs without Ethernet

Datalogger web pulses counter The web datalogger pulses counter is able to count the pulses on the digital inputs (2 by default expandable). Through the web interface (RNDIS protocol) it is possible to display count values, change the pulse weight and enter an offset in the event of misalignment or assembly after the installation of the counter. All data can be viewed via the web interface or reachable via MODBUS RTU connection. The datalogger as optional feature can be ordered time triggered recording of the counters on csv files in the internal memory or in a SD card. Files can be downloaded via ftp Server functionality.

Marcom Srl, Via Mezzacampagna 52 Verona 37125

www.marcomweb.it

1-EN


MarCom

Features Connections        

1 x Serial Port RS232 not used 1 x Serial Port RS485 for reading data from a master Modbus RTU 1 x Port MiniUSB 1 screw connector for power supply 10 30 VDC (min. 2 W) Signaling LED on the front for communication diagnostics 6 x Digital Input 4 x Digital Output 2 x Analog Input

Analog Input Connections

Marcom Srl, Via Mezzacampagna 52 Verona 37125

www.marcomweb.it

2-EN


MarCom

Change connection settings To change device settings you need to connect it to a PC using the USB port. The physical connection between the PC and the PLC must be done with an USB cable A to mini-B type. This connection uses the Microsoft RNDIS protocol, which creates a virtual Ethernet port on the PC. When the device is connected to the PC for the first time the system will detect the new device and install the RNDIS driver. The operations for setting the IP address on the PC are as follows (Windows 7): 1. On Start, click Control Panel; 2. On Control Panel, double-click Network and Sharing Center;

3. The active network connection list window will open; click on the highlighted link 4. The connection status window will open; click on Properties 5. The properties window of the RNDIS connection will open: select Internet Protocol version 4 (TCP/IPv4) and then properties 6. The properties window of the selected Internet protocol will open: set an IP address compatible with the address of the device to connect to.

Marcom Srl, Via Mezzacampagna 52 Verona 37125

www.marcomweb.it

3-EN


MarCom

Web visualization To view the web pages containing the data, it is necessary to connect the data logger to the Ethernet network through the RJ45 port. On a web browser just enter the default address: 192.168.1.122; If you do not connect, check that you have an address on the network card of the computer on the 192.168.1.X subnet. (see section "Change connection settings"). This way you get to the main screen of the data logger with the values of the counters.

From this page, through the links at the top of the page, you can access the following pages: - Setting datalogger; Page to set the pulse counter parameters, such as pulse weight and count offset. - Hardware setup; Page to modify the hardware parameters of the pulse counter as IP address and Modbus communication parameters. - Time setup; Page to change the time or activate the NTP protocol. - System; Page to log in to enable changes and to reboot the system.

Marcom Srl, Via Mezzacampagna 52 Verona 37125

www.marcomweb.it

4-EN


MarCom

Setting datalogger

In the Setting datalogger page you can reset the values of the counters, change the weight of the pulses and the offsets.

Marcom Srl, Via Mezzacampagna 52 Verona 37125

www.marcomweb.it

5-EN


MarCom

Hardware setup

In this page it is possible to modify the parameters of the RTU modbus connection on the COM2 port (RS485). After modifying and saving the parameters, the device must be restarted. This can also be done from the System page.

System

In this page you can login (Username = Admin, Password = Admin), necessary to change the parameters, and force the device to restart.

Marcom Srl, Via Mezzacampagna 52 Verona 37125

www.marcomweb.it

6-EN


MarCom

Mapping of Modbus memory areas The data read by the PLC are placed in the memory area Holding Register, they occupy 2 WORD, that is 4 BYTE. Nome variabile

Tipo

RESET INPUT 1 INPUT 2 INPUT 3 INPUT 4 INPUT 5 INPUT 6 CONTATORE 1 CONTATORE 2 CONTATORE 3 CONTATORE 4 CONTATORE 5 CONTATORE 6 PESO_IMP_1 PESO_IMP_2 PESO_IMP_3 PESO_IMP_4 PESO_IMP_5 PESO_IMP_6 OFFSET_1 OFFSET_2 OFFSET_3 OFFSET_4 OFFSET_5 OFFSET_6

UINT UINT UINT UINT UINT UINT UINT REAL REAL REAL REAL REAL REAL REAL REAL REAL REAL REAL REAL REAL REAL REAL REAL REAL REAL

Indirizzo MODBUS 1 2 3 4 5 6 7 1025 1027 1029 1031 1033 1035 1075 1077 1079 1081 1083 1085 1125 1127 1129 1131 1133 1135

Note Reset dei contatori 1° ingresso digitale 2° ingresso digitale 3° ingresso digitale 4° ingresso digitale 5° ingresso digitale 6° ingresso digitale 1° contatore: riferito all’ingresso 0 2° contatore: riferito all’ingresso 1 3° contatore: riferito all’ingresso 2 4° contatore: riferito all’ingresso 3 5° contatore: riferito all’ingresso 4 6° contatore: riferito all’ingresso 5 Peso assegnato per gli impulsi sul contatore 1 Peso assegnato per gli impulsi sul contatore 2 Peso assegnato per gli impulsi sul contatore 3 Peso assegnato per gli impulsi sul contatore 4 Peso assegnato per gli impulsi sul contatore 5 Peso assegnato per gli impulsi sul contatore 6 Offset del contatore 1 Offset del contatore 2 Offset del contatore 3 Offset del contatore 4 Offset del contatore 5 Offset del contatore 6

Marcom Srl, Via Mezzacampagna 52 Verona 37125

www.marcomweb.it

7-EN


MarCom

Gateway Size The dimensions of the gateway are as follows:

Marcom Srl, Via Mezzacampagna 52 Verona 37125

www.marcomweb.it

8-EN