Presence Detectors | Technology Guide
An Introduction to Detector Types The following pages describe the functionality of the three types of detector that we offer 1. Switching detectors without lux (light) level sensing
Suitable for switching lighting in rooms without natural daylight. These products can also be used to control heating and ventilation loads.
2. Switching detectors with lux (light) level sensing
Ideally suited to switching lighting in rooms with natural daylight.
3. Dimming detectors
These detectors have a wide range of functionality to enable lux (light) levels to be maintained whilst using the minimum amount of energy. They are ideally suited to applications where maximum efficiency and flexibility are required.
Load Capacity Key Suitable for the control of heating
Suitable for the control of lighting
Suitable for the control of ventilation
1. Switching Detectors without Lux Level Sensing Detectors without lux level sensing are ideally suited to switch lighting in rooms without any natural light. These products can also be used to control heating and ventilation loads.
Key Detectors without Lux Level Sensing
No presence detected, lights off
Presence detected, lights on
Our range of switching presence detectors without lux level sensing Wall Mounted Detectors Code
Description
Ceiling Mounted Detectors Code
Description
SPIR-F
PIR presence detector with time delay function
EBMPIRB/SA/C
Miniature PIR presence/absence detector with time delay function
SPIR-FVF
PIR presence detector with time delay function and voltage free contact
MWS1/C
Microwave presence detector with time delay function
MWS1
Microwave presence detector with time delay function
MWS1/CIP
Microwave presence detector with time delay function and IP66 rating
MWS1-FVF
Microwave presence detector with time delay function and voltage free contact
MWS1/IP
Microwave presence detector with time delay function and IP66 rating
Please call +44 (0)333 900 0671 or visit www.cpelectronics.co.uk for more information
Presence Detectors | Technology Guide
2. Switching Detectors with Lux Level Sensing These presence detectors have built-in adjustable lux sensors which will keep the lighting switched off if there is sufficient natural light. All ceiling mounted PRM presence detectors can be set up from ground level using our simple programming handset. A wide range of user infrared controls are available for increased flexibility.
No presence detected, daylight, lights off
Presence detected, sufficient daylight, lights off
Presence detected, insufficient daylight, all lights on
No presence detected, lights off
Key Detectors with Lux Level Sensing
Our range of switching presence detectors with lux level sensing Wall Mounted Detectors Code
Description
Ceiling Mounted Detectors Code
Description
PDS-PRM
Contemporary no neutral PIR presence detector with lux level sensing and time delay function
SPIR-F/C
Ceiling mounted PIR presence detector for square accessory box
PDS
No neutral PIR presence detector with lux level sensing and time delay function
EBDSPIR
Compact PIR presence detector with lux level sensing and time delay function
PDS/OV
No neutral PIR presence detector with lux level sensing, override switch and time delay function
EBDSPIRPRM
Compact PIR presence/absence detector with lux level sensing, time delay function and infrared override
SPIR-PRM
Contemporary PIR presence detector with lux level sensing and time delay function
EBMPIRPRM/SA/C
Miniature PIR presence/absence detector with lux level sensing, time delay function and infrared override
SPIR-LSF
PIR presence detector with lux level sensing and time delay function
MWS1/C/LUX
Microwave presence detector with lux level sensing and time delay function
MWS1/LUX
Microwave presence detector with lux level sensing and time delay function
MWS1/C/IP/ LUX
Microwave presence detector with lux level sensing, time delay function and IP66 rating
MWS1-FVF/ LUX
Microwave presence detector with lux level sensing, voltage free contact and time delay function
MWS3APRM
Adjustable head microwave presence/absence detector with lux level sensing, infrared override and time delay function
MWS1/IP/ LUX
Microwave presence detector with lux level sensing, time delay function and IP66 rating
Compact microwave presence/absence detector with MWS5-PRM/ lux level sensing, infrared override and time delay SA/C function MWS6-PRM
Low profile microwave presence/absence detector with lux level sensing, infrared override and time delay function
High bay PIR presence detector EBDSPIR-HBwith lux level sensing, infrared override and time delay PRM function
Please call +44 (0)333 900 0671 or visit www.cpelectronics.co.uk for more information
Presence Detectors | Technology Guide
3. Dimming Detectors with Lux Level Sensing Our Direct Dim technology incorporates dimming functionality plus a host of additional advanced features, please see page opposite.
Key Dimming Detectors with Lux Level Sensing
Presence detected, some daylight. Lights on and dimmed to maintain lux level
No presence detected, daylight, lights off
Presence detected, sufficient daylight, lights off
Presence detected, insufficient daylight. Dimming detector measures and implements maintained illuminance
No presence detected, lights off
In addition to presence/absence detection and lux level sensing dimming detectors are able to provide automatic control of lighting output. A dimming detector can be used to control the light output of luminaires that are fitted with dimming ballasts. The detector measures the overall light level in the detection area and calculates the correct output for the luminaires, to a maintained illuminance (preset lux level), thereby saving energy by using natural daylight.
Ceiling Mounted Detectors – Digital Dimming DSI / DALI Code
Description
Many lighting schemes can be ‘over lit’ because of the initial brightness of the new lamps, over compensation for dirt/lamp life, and over-design due to room shape and size. Therefore installed lighting often needs to be ‘dimmed’ to achieve the correct illuminance level, and increase gradually to compensate for the anticipated light loss.
Ceiling Mounted Detectors – Analogue Dimming 1–10V Code
Description
EBDSPIR-DD
PIR presence/absence detector with Direct Dim and time delay function
EBDSPIR-AD
Presence detector with 1–10V analogue dimming output (up to 10 ballasts)
EBMPIRDD/SA/C
Miniature PIR presence/absence detector with Direct Dim and time delay function
EBMPIRAD/SA/C
Miniature presence detector with 1–10V analogue dimming output
MWS3A-DD
Adjustable head microwave presence/absence detector with Direct Dim and time delay function
MWS3A-AD
Adjustable head microwave presence/absence detector for 1–10V analogue dimming output
MWS5DD/SA/C
Compact microwave presence/absence detector with Direct Dim and time delay function
MWS6-DD
Low profile microwave presence/absence detector with Direct Dim and time delay function
EBDSPIRHB-DD
High bay PIR presence detector with Direct Dim and time delay function
MWS7
Adjustable high bay microwave presence detector with Direct Dim and time delay function
Please call +44 (0)333 900 0671 or visit www.cpelectronics.co.uk for more information
Presence Detectors | Technology Guide
Direct Dim Overview
Adjustments and Programming
As well as dimming functionality (see page opposite) and presence/ absence detection, Direct Dim technology from CP Electronics offers a host of additional features and functionality.
Direct Dim detectors feature integral infrared receivers to allow the units to be programmed using the optional DD-LCDHS programming handset. This gives complete control over many of the operating parameters.
Two Channel Flexibility
Manual adjustments may also be made to the sensitivity, lux and time settings using the controls on the detector.
The dimming channel of the detector can be used to control the light output of luminaires that are fitted with dimming ballasts. The detector measures the overall light level in the detection area and calculates the correct output for the luminaires, to maintain a preset lux level (maintained illuminance). The switching channel of the detector can either be used to isolate the supply to the dimming ballasts (saving on the standby current of the ballasts) or to switch a separate channel of standard, non-dimming luminaires. Two input terminals can be used to manually override the dimming levels and override the lights on or off. The flexibility of having two channels and two switch inputs allows the following scenarios: 1. Dim an outside row of luminaires whilst internal fittings are switched 2. Provides absence detection for two separate channels 3. Maintained illuminance system with manual up/down controls
Programming Handsets DD-LCDHS and DD-LCDHS-LR
Our programming handset is available in two versions, the standard model for conventional height ceilings and the ‘LR’ version for use in high ceiling applications such as warehouses. The handsets allow programming and control of all Direct Dim functionality including: ● switching and dimming channel control ● detection sensitivity ● lux hold-off and time delay ● step-down illuminance ● scene settings ● lamp burn-in settings
Step-down Illuminance
In certain instances it may be undesirable to simply switch off light should no movement or presence be detected. Direct Dim detectors can be programmed to switch off light completely or lower its level to a predefined value, upon sensing no movement.
User Handset UHS
This handset allows the user to override the system detectors to turn lights on or off, adjust lux levels or select preset scenes.
Scene Setting and Recall
Direct Dim detectors allow the user to create and recall desired room lighting levels. A meeting room for example would require different levels of lighting if it was to be used for a multimedia presentation or a board meeting. Lamp Burn-in
User Handset UHS3
This handset allows the user to override the system detectors to turn lighting on or off.
Some manufacturers state that dimming a lamp within the first hours of use can shorten its overall life and therefore invalidate its warranty. The Direct Dim ‘burn-in’ feature is intelligent software programming that prevents new lamps from being dimmed for this initial period. Load Capacity
Digital Direct Dim detectors can control as many as 20 dimming ballasts, analogue Direct Dim detectors up to 10.
User Handset UHS3 (2)
This handset allows the user to override the system detectors to turn lighting off.
Suitable for all Lighting Types
Direct Dim detectors can be used for all lighting. DD=Digital Dim DSI / DALI AD=Analogue Dim 1–10V
Please call +44 (0)333 900 0671 or visit www.cpelectronics.co.uk for more information