temperature probes Bare Thermoresistive Sensor SR PLATINUM TEMPERATURE SENSOR Sheath - thin film. Leads - radial ø0.25 mm. Electroplated - Ag5%Pd. Accuracy class 'B' or 'A'. Sensor view
Sensor code
SRR
Technical specifications
Temperature range
H [mm]
RO [Ω]
3 ± 0.2
1.3 ± 0.2
1 × 100
T1
-50...400 °C
T11
-50...600 °C
2 ± 0.2
1.3 ± 0.2
1 × 100
T1
-50...400 °C
T11
-50...600 °C
5 ± 0.2
2 ± 0.2
1.3 ± 0.2
1 × 100
T1
-50...400 °C
T11
-50...600 °C
2.3 ± 0.2
2 ± 0.2
1.3 ± 0.2
1 × 100
T1
-50...400 °C
T11
-50...600 °C
1.3 ± 0.2
1 × 1000
T1
-50...400 °C
T11
-50...600 °C
L [mm]
B [mm]
2100
10 ± 0.2
2101
10 ± 0.2
2103 2105 2141
10 ± 0.2
2 ± 0.2
SPECIAL SENSORS 2.5 ± 0.2
2106
5 ± 0.2
2 ± 0.2
1.3 ± 0.2
1 × 50
T1
-50...400 °C
1.15
1.3 ± 0.2
1 × 100
T1
-50...400 °C
PLATINUM TEMPERATURE SENSOR Sheath - thin film. Leads - axial ø0.25 mm. Electroplated - Ag5%Pd. Accuracy class 'B' or 'A'. Sensor view
Sensor code
2105
SRA
Technical specifications L [mm]
B [mm]
H [mm]
RO [Ω]
2.3 ± 0.2
2 ± 0.2
1.4 ± 0.3
1 × 100
Temperature range
T1
-50...400 °C
PLATINUM TEMPERATURE SENSOR Sheath - thin film (SMD). Leads - for surface mounting. Accuracy class 'B' Sensor view
Sensor code
2000
SRM
Technical specifications L [mm]
B [mm]
H [mm]
RO [Ω]
3 ± 0.2
1.5 ± 0.2
0.5 ± 0.1
1 × 100
Temperature range
T12
-10...100 °C
PLATINUM TEMPERATURE SENSOR Sheath - thin film. Leads - radial ø0.25 mm. Electroplated - Ag5%Pd. Accuracy class 'B' or 'A'. Sensor view
Sensor code
SRC
Technical specifications
Temperature range
L [mm]
ø [mm]
RO [Ω]
2100
12 ± 1
4.5 ± 0.2
1 × 100
T1
-50...400 °C
T11
-50...600 °C
2102
12 ± 1
3 ± 0.2
1 × 100
T1
-50...400 °C
T11
-50...600 °C
2103
6± 1
2 ± 0.2
1 × 100
T1
-50...400 °C
T11
-50...600 °C
2202
12 ± 1
3 ± 0.2
2 × 100
T1
-50...400 °C
T11
-50...600 °C
WIRE-WOUND COPPER TEMPERATURE SENSOR Sheath - stainless steel 1.4301. Sensor view
Sensor code
SRC Technical specifications
Temperature range
L [mm]
ø [mm]
RO [Ω]
3100
25 ± 1
4 ± 0.2
1×
50
T9
-50...200 °C
3101
32 ± 1
5 ± 0.2
1×
50
T9
-50...200 °C
3110
40 ± 1
4 ± 0.2
1 × 100
T9
-50...200 °C
3111
80 ± 1
5 ± 0.2
1 × 100
T9
-50...200 °C
3201
32 ± 1
5 ± 0.2
2×
T9
-50...200 °C
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
50
COMECO reserves the right of changing specifications without prior notice!
2155
temperature probes
WIRE-WOUND PLATINUM TEMPERATURE SENSOR Sheath - ceramic. Leads - pure platinum. Accuracy class 'B' or 'A'. Sensor code
ø [mm]
Leads ø [mm]
RO [Ω]
Temperature range
4301 (8301)
30 ± 0.5
4.5 - 0.03
0.40
1(2) × 100
T2
-200...850 °C
4302 (8302)
30 ± 0.5
3.8 - 0.03
0.40
1(2) × 100
T2
-200...850 °C
4251 (8251)
25 ± 0.5
3.2 - 0.03
0.40
1(2) × 100
T2
-200...850 °C
4252 (8252)
25 ± 0.5
3.0 - 0.03
0.40
1(2) × 100
T2
-200...850 °C
4253 (8253)
25 ± 0.5
2.8 - 0.03
0.40
1(2) × 100
T2
-200...850 °C
4254 (8254)
25 ± 0.5
2.4 - 0.03
0.40
1(2) × 100
T2
-200...850 °C
4255 (8255)
25 ± 0.5
1.5 - 0.03
0.27
1(2) × 100
T2
-200...850 °C
4201 (8201)
20 ± 0.5
2.0 - 0.03
0.27
1(2) × 100
T2
-200...850 °C
4151 (8151)
15 ± 0.5
4.5 - 0.03
0.40
1(2) × 100
T2
-200...850 °C
4152 (8152)
15 ± 0.5
3.2 - 0.03
0.40
1(2) × 100
T2
-200...850 °C
4153 (8153)
15 ± 0.5
3.0 - 0.03
0.40
1(2) × 100
T2
-200...850 °C
4154 (8154)
15 ± 0.5
2.8 - 0.03
0.40
1(2) × 100
T2
-200...850 °C
4155 (8155)
15 ± 0.5
2.4 - 0.03
0.40
1(2) × 100
T2
-200...850 °C
4156 (8156)
15 ± 0.5
2.0 - 0.03
0.27
1(2) × 100
T2
-200...850 °C
4157 (8157)
15 ± 0.5
1.5 - 0.03
0.27
1(2) × 100
T2
-200...850 °C
4158 (8158)*
15 ± 0.5
1.2 + 5%
0.27
1(2) × 100
T2
-200...850 °C
4159 (8159)*
15 ± 0.5
0.9 + 5%
0.15
1(2) × 100
T2
-200...850 °C
4150 (8150)*
15 ± 0.5
0.8 + 5%
0.15
1(2) × 100
T2
-200...850 °C
4101 (8101)*
10 ± 0.5
1.6 - 0.03
0.27
1(2) × 100
T2
-200...850 °C
4102 (8102)*
10 ± 0.5
1.2 + 5%
0.27
1(2) × 100
T2
-200...850 °C
4103 (8103)*
10 ± 0.5
0.8 + 5%
0.15
1(2) × 100
T2
-200...850 °C
4081 (8081)*
8 ± 0.5
1.5 - 0.03
0.27
1(2) × 100
T2
-200...850 °C
4061 (8061)*
6 ± 0.5
2.0 + 3%
0.27
1(2) × 100
T2
-200...850 °C
4041 (8041)*
4 ± 0.3
4.5 + 3%
0.40
1(2) × 100
T2
-200...850 °C
Ordering code
SR - G2.G3.G11
Code Feature or option
Technical specifications L [mm]
Code values
Variant
R, A, M, C
G2
Sensor (1)
code (from tables above)
G3
Temperature range (1)
T1 - -50…400 °C, T2 - -200…850 °C, T9 - -50…200 °C, T11 - 50…600 °C, T12 - 10…100 °C
G11
Accuracy class
A - 'A', B - 'B'
(1)
Do not code if there is only one possible for the selected variant.
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Sensor view
SRC
temperature probes Thermocouples without Sheath ST (Bare T/Cs and ceramic insulated T/Cs)
BASE METAL
Variant Material Wire diameter ('ø') [mm] Maximum temperature [°C] Isolation
J
K
Fe-CuNi
NiCr-Ni
1.0 800
1.5 800
E
NiCr-CuNi 0.5 1.0 1.5 3.0 1.5 3.0 800 1000 1100 1200 800 900 1- , 2-, or 4-hole steatite ceramic beads (max. 1200 °C) (option)
L (GOST) NiCr-CuNi 1.2 3.2 700 800
NOBLE METAL Variant
S
Material Wire diameter ('ø') [mm] Maximum temperature [°C] Isolation
Ordering code
B
C Wo5%Re-Wo26%Re 0.5 2320 none
ST - G4.(G6) - #1.#2
Code Feature or option
R
Pt10%Rh-Pt Pt13%Rh-Pt Pt30%Rh-Pt6%Rh 0.35 0.5 0.35 0.5 0.35 0.5 1600 1600 1600 1600 1800 1800 2- or 4-hole alumina ceramic rod (up to 1500, 1600, or 1700 °C) (option)
Variant
Code values J, K, E, L, S, R, B, C
(1)
G4
Wire diameter 'ø' [mm]
G6
Length [m]
length
0.35, 0.5, 1.0, 1.2, 1.5, 3.0, 3.2
#1
Isolation (1)
X - none, CZ - ceramic beads (2), C1 - ceramic rod '610' up to 1500 °C, C2 - ceramic rod '710' up to 1600 °C and up to 1 m, C3 - ceramic rod '799' up to 1700 °C
#2
Packing
X - none, R - on rolls
(1)
COMECO reserves the right of changing specifications without prior notice!
Applicable for the selected variant (2) Up to 25 m; with 1, 2, or 4 holes, depending on the variant
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
Insulation - Teflon®, silicone, fiberglass, or ceramic (see table notes) Wire leads - Cu, Ni, or Ag (see table notes)
MAXIMUM TEMPERATURE
TSEx DESIGN
RTD ELEMENT WITH LEADS
1
200 °C
INSULATION
element
LEADS
leads
outer none
DESIGN 1 (TSE1)
Teflon®
Teflon®
Teflon® silicone
2
400 °C 550 °C
3
400 °C 600 °C 800 °C
ceramic, cement
ceramic beads
4
400 °C 600 °C 800 °C
ceramic, cement
ceramic rod
L = 100 … 2000 mm
DESIGN 2 (TSE2)
SS tube, cement
glass sleeves
none glass
type
Cu stranded 0.14(22) mm2 Cu, Ni solid 0.5 mm
wires 2, 3, 4*
2x2
2, 3, 4*
2x2
2, 3, 4*
2x2
2, 3, 4*
2x2
2, 3, 4*
2x2
-
Cu, Ni, Ag solid 0.5 mm
2, 3, 4
2x2
-
Cu, Ni, Ag solid 0.5 mm
2, 3, 4
2x2
RTD element: (simplex or duplex) Pt50 (RB), Pt100 (RD), Pt500 (RF), Pt1000 (RG) Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Minimum mounting hole diameter ('d'): Wire leads
L = 100 … 2000 mm
DESIGN 3 (TSE3)
Design
2
3
4
no outer insulation
3 mm
4 mm
1
Teflon® outer insulation
4 mm
5 mm
silicone outer insulation
5 mm
6 mm
6 mm
2
no outer insulation glass outer insulation
4 mm 5 mm
5 mm
6 mm
6 mm
6 mm
3
5 mm
4
6 mm
5 mm
Outer diameter: d1 ≤ d - 0.5 mm
DESIGN 4 (TSE4)
Wire material: Cu (up to 450 °C), Ni, or Ag Insulation material: - silicone or Teflon® (max. 200 °C) - glass fiber (max. 550 °C) - SS 316 (max. 850 °C) - ceramic 610 (max. 1500 °C) Lead termination: - free (flying) leads, 10...15 mm non-insulated - ceramic base and screw terminals for heads w/ 20 mm mounting distance - ceramic base and screw terminals for heads w/ 33 mm mounting distance
L = 100 … 1000 mm * Please contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
L = 100 … 2000 mm
temperature probes
Ordering code TSE(1,2,3,4) - G1G2.G3.G4.G8.G11.G12.G13 - #1.#2 Code Feature or option
Code values
G1
Number of RTD sensors
1, 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000
G3
Temperature range (1)
T1 - -50…400 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C (2)
G4
Mounting hole diameter 'd' (1)
3 - ≥ 3 mm (5), 4 - ≥ 4 mm, 5 - ≥ 5 mm, 6 - ≥ 6 mm, 7 - > 6 mm
G8
Lead length 'L' [mm]
100…2000 (1)
G11
Accuracy class
A - 'A', B - 'B', C - '2xB'
G12
Number of wires (1)
2, 3, 4 (5)
G13
Wire material (1)
CU - copper (3), NI - nickel, AG - silver
#1
Additional outer lead insulation
X - none, I - mounted (4)
#2
Lead termination options
X - none (free leads), M - ceramic base and screw terminals for heads w/ 20 mm mounting distance, B - ceramic base and screw terminals for heads w/ 33 mm mounting distance
(1)
Applicable for the selected design Up to 550 °C for TSE2! Not applicable for temperatures above 450 °C! (4) Only for TSE1 and TSE2! (5) Contact COMECO!
(2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
(MI**) RTD CABLE PROBE FOR FREE MOUNTING
TSAx
Sheath - stainless steel (see table notes) Cable - see table notes
SENSITIVE ELEMENT
1 x Pt (RB,RD,RF,RG)
STRAIGHT-TUBE DESIGN (TSA)
2 x Pt (RB,RD,RF,RG) n = 20 … 200 mm
k = 1 … 10 m
1 x Cu (RH, RK) 2 x Cu (RH, RK)
DESIGN WITH ANGLED TERMINATION (TSAL)
CABLE TYPE
TEMPERATURE RANGE
SLSL, TSL, TT, YY, UU, YU
T9 T1*
GLGL
T7 T8
-50...200 °C -50...400 °C
DIMENSIONS d [mm]
wires
3*
2, 3*
4, 4.5**
2, 3*
5
2, 3*
6
2, 3, 4*
8
2, 3, 4
0...200 °C 0...400 °C
TT
T22 -200...200 °C
6, 8
SLSL, TSL, YY, UU, YU
T9
-50...200 °C
GLGL, TT
T7
0...200 °C
2x2, 2x3*
5*
2, 3*
6
2, 3, 4*
8
2, 3, 4
6, 8
2x2, 2x3*
1 x PTC (RP, RQ)
SLSL, TSL, YY, UU, YU
T12
-50...100 °C
6
2, 3
2 x PTC (RP, RQ)
GLGL, TT
T19
0...100 °C
8
2x2
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Applicable cables: n = 20 … 200 mm
k = 1 … 10 m
Probe design Temp. range T12, T19
BENDED-TUBE DESIGN (TSAB)
TSA, TSAB
TSAL
all
all
T7, T9 T22
no PUR, no PVC TT
TT, SLSL, TSL
T1, T8
GLGLP
no PUR, no PVC
Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes)
Cable connector: 4-pin (C3) (see Appendix - Connectors) n = 20 … 200 mm m = 30 ... 200 mm
k = 1 … 10 m * Please contact COMECO! ** Available only for TSAL!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance)
temperature probes
Ordering code
TSA(L,B) - (MI -(1)) G1G2.G3.G4.G6.G7.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option
Code values
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP - PTC 1k, RQ - PTC 2k
G3
Temperature range
T1 - -50…400 °C, T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T12 - 50…100 °C, T19 - 0…100 °C, T22 - -200…200 °C
G4
Diameter 'd' [mm]
G6
Probe length 'n' [mm]
regular design
4, 5, 6, 8
MI design
3 (5), 4.5, 6, 8 20…200
(2)
G7
Probe length 'm' [mm]
G8
Cable length 'k' [m] and type
G10
Sheath material (wetted parts)
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
G11
Accuracy class
X - none (3), A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (5)
G14
Tip shape
X - standard closed, N - narrowed (4), P - pitted (4)
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only)
Options
X - none, OV - vibration proof (MgO or Silicone filled) (4), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface (4)
#1
30…200 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (5), 1PV…10PV - PVC
(1)
Available only for TSAL! Only for TSAB! For non-Pt sensors (4) Only for non-MI (regular) design! (5) Contact COMECO!
(2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
(MI**) T/C CABLE PROBE FOR FREE MOUNTING
TSAx
Sheath - stainless steel (see table notes) Cable - see table notes
SENSITIVE ELEMENT
CABLE TYPE
DIMENSIONS
TEMPERATURE RANGE
d [mm]
wires
Regular Design
STRAIGHT-TUBE DESIGN (TSA) 1xK
n = 20 … 200 mm
k = 1 … 10 m
1 x J, 1xT
SLSL, TSL, YY, UU, YU
T9 T1*
GLGL, TT, SFSF
T7 T8
-50...200 °C -50...400 °C 0...200 °C 0...400 °C
T4*
0...800 °C
SLSL, TSL, YY, UU, YU
T9 T1*
-50...200 °C -50...400 °C
GLGL, TT, SFSF
T7 T8
4, 5, 6, 8
2
4, 5, 6, 8
2
3, 4.5, 6, 8
2
3, 4.5, 6, 8
2
0...200 °C 0...400 °C
MI Design **
DESIGN WITH ANGLED TERMINATION (TSAL)
SLSL, TSL, YY, UU, YU
T9 T1*
GLGL, TT, SFSF
T7 T8
-50...200 °C -50...400 °C
1 x N, 1xE
0...200 °C 0...400 °C
T4*
0...800 °C
SLSL, TSL, YY, UU, YU
T9 T1*
-50...200 °C -50...400 °C
GLGL, TT, SFSF
T7 T8
1xT 0...200 °C 0...400 °C
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9), 1.4841 (M5), 2.4816 (M8) k = 1 … 10 m
BENDED-TUBE DESIGN (TSAB)
Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) - SFSF (mineral fiber, max. 1000 °C ambient temperature) Applicable cables: Probe design Temp. range T7, T9 T1, T8 T4
n = 20 … 200 mm m = 30 ... 200 mm
k = 1 … 10 m
TSA, TSAB
TSAL
no PUR, no PVC
all
GLGLP, SFSF
no PUR, no PVC
SFSF
GLGLP, SLSL*, TSL*
Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors)
* Please contact COMECO! ** Available only for TSAL!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
n = 20 … 200 mm
temperature probes
Ordering code
TSA(L,B) - (MI -(1)) G2.G3.G4.G6.G7.G8.G10.G11.G14.G15 - #1
Code Feature or option
Code values regular design
J - type "J", K - type "K", T - type "T"
G2
Thermocouple
G3
Temperature range
G4
Diameter 'd' [mm]
G6
Probe length 'n' [mm]
20…200
G7
Probe length 'm' [mm] (2)
30…200
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1MF…10MF - mineral fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1PV…10PV - PVC
G10
Sheath material (wetted parts)
G11
Accuracy class
1 - '1' (4), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled) (3), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface (3)
MI design
E - type "E", N - type "N", T - type "T" T1 - -50…400 °C, T4 - 0…800 °C (4), T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C
regular design MI design
4 (4), 5, 6, 8 3, 4.5, 6, 8
regular design
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
MI design
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404
(1)
Available only for TSAL! Only for TSAB! Only for non-MI (regular) design! (4) Contact COMECO!
(2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
(MI**) RTD CABLE PROBE FOR FREE MOUNTING
TSAx
Sheath - stainless steel (see table notes) Cable - see table notes
SENSITIVE ELEMENT
1 x Pt (RB,RD,RF,RG)
STRAIGHT-TUBE DESIGN (TSA)
2 x Pt (RB,RD,RF,RG) n = 20 … 200 mm
k = 1 … 10 m
1 x Cu (RH, RK) 2 x Cu (RH, RK)
DESIGN WITH ANGLED TERMINATION (TSAL)
CABLE TYPE
TEMPERATURE RANGE
SLSL, TSL, TT, YY, UU, YU
T9 T1*
GLGL
T7 T8
-50...200 °C -50...400 °C
DIMENSIONS d [mm]
wires
3*
2, 3*
4, 4.5**
2, 3*
5
2, 3*
6
2, 3, 4*
8
2, 3, 4
0...200 °C 0...400 °C
TT
T22 -200...200 °C
6, 8
SLSL, TSL, YY, UU, YU
T9
-50...200 °C
GLGL, TT
T7
0...200 °C
2x2, 2x3*
5*
2, 3*
6
2, 3, 4*
8
2, 3, 4
6, 8
2x2, 2x3*
1 x PTC (RP, RQ)
SLSL, TSL, YY, UU, YU
T12
-50...100 °C
6
2, 3
2 x PTC (RP, RQ)
GLGL, TT
T19
0...100 °C
8
2x2
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Applicable cables: n = 20 … 200 mm
k = 1 … 10 m
Probe design Temp. range T12, T19
BENDED-TUBE DESIGN (TSAB)
TSA, TSAB
TSAL
all
all
T7, T9 T22
no PUR, no PVC TT
TT, SLSL, TSL
T1, T8
GLGLP
no PUR, no PVC
Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes)
Cable connector: 4-pin (C3) (see Appendix - Connectors) n = 20 … 200 mm m = 30 ... 200 mm
k = 1 … 10 m * Please contact COMECO! ** Available only for TSAL!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance)
temperature probes
Ordering code
TSA(L,B) - (MI -(1)) G1G2.G3.G4.G6.G7.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option
Code values
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP - PTC 1k, RQ - PTC 2k
G3
Temperature range
T1 - -50…400 °C, T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T12 - 50…100 °C, T19 - 0…100 °C, T22 - -200…200 °C
G4
Diameter 'd' [mm]
G6
Probe length 'n' [mm]
regular design
4, 5, 6, 8
MI design
3 (5), 4.5, 6, 8 20…200
(2)
G7
Probe length 'm' [mm]
G8
Cable length 'k' [m] and type
G10
Sheath material (wetted parts)
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
G11
Accuracy class
X - none (3), A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (5)
G14
Tip shape
X - standard closed, N - narrowed (4), P - pitted (4)
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only)
Options
X - none, OV - vibration proof (MgO or Silicone filled) (4), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface (4)
#1
30…200 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (5), 1PV…10PV - PVC
(1)
Available only for TSAL! Only for TSAB! For non-Pt sensors (4) Only for non-MI (regular) design! (5) Contact COMECO!
(2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
(MI**) T/C CABLE PROBE FOR FREE MOUNTING
TSAx
Sheath - stainless steel (see table notes) Cable - see table notes
SENSITIVE ELEMENT
CABLE TYPE
DIMENSIONS
TEMPERATURE RANGE
d [mm]
wires
Regular Design
STRAIGHT-TUBE DESIGN (TSA) 1xK
n = 20 … 200 mm
k = 1 … 10 m
1 x J, 1xT
-50...200 °C -50...400 °C
SLSL, TSL, YY, UU, YU
T9 T1*
GLGL, TT, SFSF
T7 T8
0...200 °C 0...400 °C
T4*
0...800 °C
SLSL, TSL, YY, UU, YU
T9 T1*
-50...200 °C -50...400 °C
GLGL, TT, SFSF
T7 T8
4, 5, 6, 8
2
4, 5, 6, 8
2
3, 4.5, 6, 8
2
3, 4.5, 6, 8
2
0...200 °C 0...400 °C
MI Design **
DESIGN WITH ANGLED TERMINATION (TSAL)
SLSL, TSL, YY, UU, YU
T9 T1*
GLGL, TT, SFSF
T7 T8
-50...200 °C -50...400 °C
1 x N, 1xE
0...200 °C 0...400 °C
T4*
0...800 °C
SLSL, TSL, YY, UU, YU
T9 T1*
-50...200 °C -50...400 °C
GLGL, TT, SFSF
T7 T8
1xT 0...200 °C 0...400 °C
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9), 1.4841 (M5), 2.4816 (M8) k = 1 … 10 m
BENDED-TUBE DESIGN (TSAB)
Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) - SFSF (mineral fiber, max. 1000 °C ambient temperature) Applicable cables: Probe design Temp. range T7, T9 T1, T8 T4
n = 20 … 200 mm m = 30 ... 200 mm
k = 1 … 10 m
TSA, TSAB
TSAL
no PUR, no PVC
all
GLGLP, SFSF
no PUR, no PVC
SFSF
GLGLP, SLSL*, TSL*
Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors)
* Please contact COMECO! ** Available only for TSAL!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
n = 20 … 200 mm
temperature probes
Ordering code
TSA(L,B) - (MI -(1)) G2.G3.G4.G6.G7.G8.G10.G11.G14.G15 - #1
Code Feature or option
Code values regular design
J - type "J", K - type "K", T - type "T"
G2
Thermocouple
G3
Temperature range
G4
Diameter 'd' [mm]
G6
Probe length 'n' [mm]
20…200
G7
Probe length 'm' [mm] (2)
30…200
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1MF…10MF - mineral fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1PV…10PV - PVC
G10
Sheath material (wetted parts)
G11
Accuracy class
1 - '1' (4), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled) (3), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface (3)
MI design
E - type "E", N - type "N", T - type "T" T1 - -50…400 °C, T4 - 0…800 °C (4), T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C
regular design MI design
4 (4), 5, 6, 8 3, 4.5, 6, 8
regular design
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
MI design
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404
(1)
Available only for TSAL! Only for TSAB! Only for non-MI (regular) design! (4) Contact COMECO!
(2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes SCREW-IN CABLE PROBE
TSAGx
Sheath - stainless steel (see table notes) Cable - see table notes
SENSITIVE ELEMENT
CABLE TYPE
TEMPERATURE RANGE
DIMENSIONS d [mm]
wires
RTD Design
STRAIGHT DESIGN WITH WELDED CONNECTION (TSAG)
1 x Pt (RB,RD,RF,RG) 2 x Pt (RB,RD,RF,RG) 1 x Cu (RH, RK)
n = 15 … 200 mm k = 1 … 10 m
STRAIGHT DESIGN WITH MOVABLE CONNECTION (TSAG2)
2 x Cu (RH, RK)
-50...200 °C -50...400 °C
4, 5
2, 3*
6
2, 3, 4*
0...200 °C 0...400 °C
8
2, 3, 4
SLSL, TSL, YY, UU, YU
T9 T1*
GLGL, TT
T7 T8
TT
T22 -200...200 °C
SLSL, TSL, YY, UU, YU
T9
-50...200 °C
GLGL, TT
T7
0...200 °C
2x2,
6, 8
2x3*
5*
2, 3*
6
2, 3, 4*
8
2, 3, 4 2x2,
6 ,8
2x3*
1 x PTC (RP, RQ)
SLSL, TSL, YY, UU, YU
T12
-50...100 °C
6
2, 3
2 x PTC (RP, RQ)
GLGL, TT
T19
0...100 °C
8
2x2
1 x K,
SLSL, TSL, YY, UU, YU
T9 T1*
-50...200 °C -50...400 °C
GLGL, TT, SFSF
T8 T4 T3*
0...400 °C 0...800 °C 0...850 °C
5, 6, 8
2
1 x J,
SLSL, TSL, YY, UU, YU
T9 T1*
-50...200 °C -50...400 °C
1xT
GLGL, TT, SFSF
T8 T4*
0...400 °C 0...800 °C
5, 6, 8
2
Thermocouple Design
1 x N, 1xE m = 30 … 100 mm k = 1 … 10 m
n = 10 … 200 mm
ANGLED DESIGN WITH WELDED CONNECTION (TSAGL)
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) - SFSF (mineral fiber, max. 1000 °C ambient temperature) Applicable cables:
k = 1 … 10 m
ANGLED DESIGN WITH MOVABLE CONNECTION (TSAGL2)
TSAG, TSAG2 all no PUR, no PVC TT GLGLP, SFSF SFSF
TSAGL, TSAGL2 all TT, SLSL, TSL no PUR, no PVC GLGLP, SFSF
Tip shape: - RTD: standard, narrowed, pitted - T/C: standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors) Available threads and HEX sizes: n = 10 … 200 mm m = 50 … 100 mm
k = 1 … 10 mm
G SW
M6
M8
10
10
M10 1/8" 12(13)
* Please contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
M12 1/4" 14
M14 17
M16 3/8" 19
M18 22
M20 1/2" 24
COMECO reserves the right of changing specifications without prior notice!
n = 15 … 200 mm
Probe design Temp. range T12, T19 T7, T9 T22 T1, T8 T3, T4
temperature probes
Ordering code
TSAG(2,L,L2) - G1G2.G3.G4.G6.G7.G8.G9.G10.G11.G12.G14.G15 - #1
Code Feature or option
Code values
G1
Number of sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP -PTC 1k, RQ - PTC 2k, J - T/C type "J", K - T/C type "K", T - T/C type "T"
G3
Temperature range
T1 - -50…400 °C, T3 - 0…850 °C (4), T4 - 0…800 °C (4), T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T12 - 50…100 °C, T19 - 0…100 °C, T22 - -200…200 °C
G4
Diameter 'd' [mm]
G6
Probe length 'n' [mm]
10…200 (see tables overleaf)
G7
Probe length 'm' [mm] (1)
30…100 (see tables overleaf)
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1MF…10MF - mineral fiber, 1PV…10PV - PVC
G9
Mounting connection
Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q7 - M12x1.5, Q8 - M14x1.5, Q10 - 1/2" NPT, Q18 - G1/8", Q19 - 1/8" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Q26 - M8x1, Q29 - M8x1.25, Q30 - M10x1.5, Q31 - M6x1, Uxx - union nut (xx - same as for Qxx)
G10
Sheath material (wetted parts)
G11
Accuracy class
RTD
4, 5, 6, 8
T/C
5, 6, 8
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
RTD
X - none (2), A - 'A', B - 'B', C - '2xB'
T/C
1 - '1' (4), 2 - '2'
(3)
2, 3, 4 (4)
G12
Number of wires
G14
Tip shape
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface
RTD
X - standard closed, N - narrowed, P - pitted
T/C
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
(1)
Only for TSAG2 and TSAGL2! For non-Pt sensors Only for RTD sensors! (4) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
SPRING THERMOCOUPLE FOR SURFACE MEASUREMENT
TSAS
Sheath - stainless steel (see table notes) Extension cable - see table notes
SENSITIVE ELEMENT 1 x J, 1xT 1 x K, 1xN
TEMPERATURE RANGE
DIMENSIONS WIRE [mm]
d [mm]
T8
0...400 °C
0.5
10, 12
T4
0...800 °C
0.5
10, 12
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9)
n = 80 … 160 mm
k = 1 ... 10 m
Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) Tip shape: exposed hot junction, flat-surfaced (see Appendix - Tip Shapes) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) Thermocouple connector: 'standard' (C5) or 'miniature' (C6) (see Appendix - Connectors)
TSAS - G2.G3.G4.G6.G8.G10.G11.G15 - #1
Code Feature or option G2
Thermocouple
Code values J - type "J", K - type "K", T - type "T", N - type "N"
G3
Temperature range
T4 - 0…800 °C, T8 - 0…400 °C
G4
Diameter 'd' [mm]
10, 12
G6
Probe length 'n' [mm]
80…160
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
G11
Accuracy class
1 - '1' (1), 2 - '2'
G15
Connector
X - none, C5 - T/C connector, C6 - miniature T/C connector
Options
X - none, OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface
#1 (1)
Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
temperature probes
CABLE PROBE WITH SCREW FIXING FOR SURFACE MEASUREMENT
TSAT
DIMENSIONS SENSITIVE ELEMENT
Sheath - stainless steel (see table notes) Cable - see table notes
CABLE TYPE
TEMPERATURE RANGE
d [mm]
wires
4, 5
2, 3*
6
2, 3, 4*
6
2x2
6
2, 3
4, 5, 6
2
RTD Design 1 x Pt (RB,RD,RF,RG) 2 x Pt (RB,RD,RF,RG) 1 x PTC (RP, RQ)
-50...200 °C -50...100 °C
SLSL, TSL, TT, YY, UU, YU
T9 T12
GLGL
T7 T8
TT
T22 -200...200 °C
SLSL, TSL, YY, UU, YU
T12
-50...100 °C
GLGL, TT
T19
0...100 °C
0...200 °C 0...400 °C
Thermocouple Design T9
-50...200 °C
1 x J,
SLSL, TSL, YY, UU, YU
1xT
GLGL, TT
T8
0...400 °C
1 x K,
n = 20 … 30 mm
k = 1 … 10 m
d
4
5
6
□
6x6
7x7
8x8
D
3
3, 4
3, 4, 5
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Tip shape: - RTD: standard - T/C: standard (isolated) or grounded (see Appendix - Tip Shapes) Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors)
COMECO reserves the right of changing specifications without prior notice!
* Please contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
Ordering code
TSAT - G1G2.G3.G4.G5.G6.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option
Code values
G1
Number of sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RP -PTC 1k, RQ - PTC 2k, J - T/C type "J", K - T/C type "K", T - T/C type "T"
G3
Temperature range
T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T12 - 50…100 °C, T19 - 0…100 °C, T22 - -200…200 °C
G4
Diameter 'd' [mm]
4, 5, 6 (1)
G5
Diameter 'D' [mm]
G6
Probe length 'n' [mm]
20…30
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (5), 1PV…10PV - PVC
G10
Sheath material (wetted parts)
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
G11
Accuracy class
G12
Number of wires (3)
G14
Tip shape (hot junction)
3, 4, 5
RTD
X - none (2), A - 'A', B - 'B', C - '2xB'
T/C
1 - '1' (5), 2 - '2' 2, 3, 4 (5)
(4)
X - standard (isolated from sheath), G - grounded
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface
(1)
Applicable for the selected diameter 'd' For non-Pt sensors Only for RTD sensors! (4) Only for thermocouples! (5) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
CERAMIC PROBE WITH EXTENSION CABLE
TSAZx
DIMENSIONS SENSITIVE ELEMENT
Sheath - ceramic (see table notes) Holding tube - stainless steel 1.4301 or 1.4541 Extension cable - see table notes
TEMPERATURE RANGE T13
DESIGN WITH HOLDING TUBE (TSAZ1)
1 x K,
T16
WIRE [mm] MI [mm]
0...1000 °C
1.0
0...1100 °C
MI 3.0, 4.5 (Inconel 600)
1xN
n [mm]
50...300; 310…600
T6
0...1200 °C
MI 3.0, 4.5 (Nicrobell®)
1xS
T5
0...1500 °C
0.35
100...300;
1xR
T14
0...1600 °C
0.5
310…600
T14
0...1600 °C
0.35
100...300;
T15
0...1700 °C
0.5
310…600
1xB
Ceramic sheath material: Oxal 710 (C2), Alsint 799 (C3), Hexoloy® (C6) (see Appendix - Sheath Materials)
DESIGN WITH HIGH-TEMPERATURE CABLE (TSAZ2)
Cable type: - SLSL or TSL (silicone, max. 250 °C ambient temperature) - GLGLP (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SFSF (mineral fiber, max. 1000 °C ambient temperature) - KFKF (ceramic fiber, max. 1200 °C ambient temperature) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)
k = 1 … 10 mm
Thermocouple connector: 'standard' (C5) or 'miniature' (C6) (see Appendix - Connectors) * Please contact COMECO!
TSAZ(1,2) - G2.G3.G6.G8.G10.G11.G15 - #1
Code Feature or option G2
Code values
Thermocouple
K - type "K", N - type "N", S - type "S", R - type "R", B - type "B"
G3
Temperature range
T5 - 0…1500 °C, T6 - 0…1200 °C, T13 - 0…1000 °C, T14 - 0…1600 °C, T15 - 0…1700 °C, T16 - 0…1100 °C
G6
Probe length 'n' [mm]
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1MF…10MF - mineral fiber, 1CF…10CF - ceramic fiber
G10
Sheath material
C2 - ceramic Oxal 710, C3 - ceramic Alsint 799, C6 - Hexoloy®
G11
Accuracy class
1 - '1' (1), 2 - '2'
G15
Connector
X - none, C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OB - braid termination lead (only w/o connector)
(1)
T/Cs "K", "N'
50…600
T/Cs "S", "R", "B"
100…600
Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
temperature probes (MI**) RTD BAYONET CABLE PROBE
TSBx
Sheath - stainless steel (see table notes) Cable - see table notes STRAIGHT-TUBE DESIGN (TSB)
SENSITIVE ELEMENT 1 x Pt (RB,RD,RF,RG)
2 x Pt (RB,RD,RF,RG) 1 x Cu (RH, RK)
n = 10 … 200 mm k = 1 … 10 m
2 x Cu (RH, RK)
CABLE TYPE
TEMPERATURE RANGE
DIMENSIONS d [mm]
wires
SLSL, TSL, TT YY, UU, YU
T7 T9
0...200 °C -50...200 °C
4, 4.5**, 5
2, 3*
6
2, 3, 4*
SLSL, TSL, TT, GLGL
T1 T8
-50...400 °C 0...400 °C
8
2, 3, 4
GLGL, SFSF TT, TSL, SLSL
T11* -50...600 °C T22 -200...200 °C
6, 8
SLSL, TSL, YY, UU, YU
T9
-50...200 °C
GLGL, TT
T7
0...200 °C
2x2, 2x3*
5*
2, 3*
6
2, 3, 4*
8
2, 3, 4
6, 8
2x2, 2x3*
1 x PTC (RP, RQ)
SLSL, TSL, YY, UU, YU
T12
-50...100 °C
6
2, 3
2 x PTC (RP, RQ)
GLGL, TT
T19
0...100 °C
8
2x2
DESIGN WITH ANGLED TERMINATION (TSBL) Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) - SFSF (mineral fiber, max. 1000 °C ambient temperature) Applicable cables: n = 10 … 200 mm k = 1 … 10 m
STRAIGHT DESIGN WITH MOVABLE CONNECTION (TSBG)
Probe design Temp. range
TSB, TSBG
T12, T19
TSBL, TSBGL
all
all
T7, T9
no PUR, no PVC
T22 T1, T8
GLGLP, SFSF
TT, SLSL, TSL no PUR, no PVC
SFSF
GLGLP, SFSF
TT
T11
Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes)
n = 10 … 200 mm k = 1 … 10 m
Cable connector: 4-pin (C3) (see Appendix - Connectors) Bayonet: ø13x1... ø20x1; aluminum, brass, or stainless steel
ANGLED DESIGN WITH MOVABLE CONNECTION (TSBGL) Available threads and HEX sizes: G SW
M8
M10 1/8"
M12 1/4"
M14
M16 3/8"
M18
M20 1/2"
10
12(13)
14
17
19
22
24
* Please contact COMECO! n = 10 … 200 mm k = 1 … 10 m
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
** Available only for TSBL and TSBGL!
COMECO reserves the right of changing specifications without prior notice!
Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance)
temperature probes
Ordering code
TSB(L,G,GL) - (MI -(1)) G1G2.G3.G4.G5'5".G6.G8.G9.G10.G11.G12.G14.G15 - #1
Code Feature or option
Code values
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP -PTC 1k, RQ - PTC 2k
G3
Temperature range
T1 - -50…400 °C, T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T11 - -50…600 °C (1,2,7), T12 - 50…100 °C, T19 - 0…100 °C, T22 - -200…200 °C
G4
Diameter 'd' [mm]
G5'
Bayonet size (3)
regular design
4, 5, 6, 8
MI design
4.5, 6, 8 (7) 13 - ø13x1, 14 - ø14x1, 15 - ø15x1, 17 - ø17x1, 20 - ø20x1, Z - other (specify!)
(3)
G5"
Bayonet material
G6
Probe length 'n' [mm]
10…200
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (7), 1MF…10MF - mineral fiber, 1PV…10PV - PVC
G9
Mounting connection (4)
Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q7 - M12x1.5, Q8 - M14x1.5, Q10 - 1/2" NPT, Q18 - G1/8", Q19 - 1/8" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Q26 - M8x1, Q29 - M8x1.25, Q30 - M10x1.5, Uxx - union nut (xx - same as for Qxx)
G10
Sheath material (wetted parts)
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
G11
Accuracy class
X - none (5), A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (7)
G14
Tip shape
X - standard closed, N - narrowed (6), P - pitted (6)
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only)
Options
X - none, OV - vibration proof (MgO or Silicone filled) (6), OS - cable protection SS spring (≈ 50 mm) (1), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface (6)
#1
AL - aluminum, BR - brass, SS - stainless steel
(1)
Available only for TSBL and TSBGL! Available only for MI design! Only for TSB and TSBL! (4) Only for TSBG and TSBGL! (5) For non-Pt sensors (6) Only for non-MI (regular) design! (7) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes (MI**) T/C BAYONET CABLE PROBE
TSBx
Sheath - stainless steel (see table notes) Cable - see table notes
SENSITIVE ELEMENT
CABLE TYPE
DIMENSIONS
TEMPERATURE RANGE
d [mm]
wires
Regular Design
STRAIGHT-TUBE DESIGN (TSB) 1xK
1xJ n = 10 … 200 mm k = 1 … 10 m
1xT
SLSL, TSL, TT YY, UU, YU
T7 T9
0...200 °C -50...200 °C
SLSL, TSL, TT, GLGL
T1 T8
-50...400 °C 0...400 °C
GLGL, SFSF
T4 T3*
SLSL, TSL, TT YY, UU, YU
T7 T9
0...200 °C -50...200 °C
SLSL, TSL, TT, GLGL
T1 T8
-50...400 °C 0...400 °C
GLGL, SFSF
T4*
YY, UU, YU SLSL, TSL, TT GLGL
T7 T9
DESIGN WITH ANGLED TERMINATION (TSBL)
1xE
1xT
STRAIGHT DESIGN WITH MOVABLE CONNECTION (TSBG)
2
4, 5, 6, 8
2
4, 5, 6, 8
2
4.5, 6, 8
2
4.5, 6, 8
2
0...800 °C 0...850 °C
0...800 °C 0...200 °C -50...200 °C
MI Design **
1 x N,
n = 10 … 200 mm k = 1 … 10 m
4, 5, 6, 8
SLSL, TSL, TT YY, UU, YU
T7 T9
0...200 °C -50...200 °C
SLSL, TSL, TT, GLGL
T1 T8
-50...400 °C 0...400 °C
GLGL, SFSF
T4 T3*
YY, UU, YU SLSL, TSL, TT GLGL
T7 T9
0...800 °C 0...850 °C 0...200 °C -50...200 °C
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9), 1.4841 (M5), 2.4816 (M8) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) - SFSF (mineral fiber, max. 1000 °C ambient temperature) Applicable cables:
n = 10 … 200 mm k = 1 … 10 m
ANGLED DESIGN WITH MOVABLE CONNECTION (TSBGL)
TSB, TSBG
TSBL, TSBGL
T7, T9
no PUR, no PVC
all
T1, T8
GLGLP, SFSF
no PUR, no PVC
T3, T4
SFSF
GLGLP, SFSF
Tip shape: standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors) Bayonet: ø13x1... ø20x1; aluminum, brass, or stainless steel Available threads and HEX sizes: G SW
n = 10 … 200 mm k = 1 … 10 m
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
M8
M10 1/8"
M12 1/4"
M14
M16 3/8"
M18
M20 1/2"
10
12(13)
14
17
19
22
24
* Please contact COMECO! ** Available only for TSBL and TSBGL!
COMECO reserves the right of changing specifications without prior notice!
Probe design Temp. range
temperature probes
Ordering code
TSB(L,G,GL) - (MI -(1)) G2.G3.G4.G5'5".G6.G8.G9.G10.G11.G14.G15 - #1
Code Feature or option
Code values regular design
J - type "J", K - type "K", T - type "T"
G2
Thermocouple
G3
Temperature range
G4
Diameter 'd' [mm]
G5'
Bayonet size (2)
13 - ø13x1, 14 - ø14x1, 15 - ø15x1, 17 - ø17x1, 20 - ø20x1, Z - other (specify!)
G5"
Bayonet material (2)
AL - aluminum, BR - brass, SS - stainless steel
G6
Probe length 'n' [mm]
10…200
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (5), 1MF…10MF - mineral fiber, 1PV…10PV - PVC
G9
Mounting connection (3)
Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q7 - M12x1.5, Q8 - M14x1.5, Q10 - 1/2" NPT, Q18 - G1/8", Q19 - 1/8" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Q26 - M8x1, Q29 - M8x1.25, Q30 - M10x1.5, Uxx - union nut (xx - same as for Qxx)
G10
Sheath material (wetted parts)
G11
Accuracy class
1 - '1' (5), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled) (4), OS - cable protection SS spring (≈ 50 mm) (1), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface (4)
MI design
E - type "E", N - type "N", T - type "T" T1 - -50…400 °C, T3 - 0…850 °C (5), T4 - 0…800 °C (5), T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C
regular design
4 (5), 5, 6, 8
MI design
4.5, 6, 8 (5)
regular design
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
MI design
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404
(1)
Available only for TSBL and TSBGL! Only for TSB and TSBL! Only for TSBG and TSBGL! (4) Only for non-MI (regular) design! (5) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
BAYONET CABLE INSERT
TSBS
Sheath - stainless steel (see table notes) Cable - see table notes
SENSITIVE ELEMENT
CABLE TYPE
TEMPERATURE RANGE
DIMENSIONS d [mm]
wires
RTD Design
1 x Pt (RB,RD,RF,RG)
SLSL, TSL
T9 T1*
GLGL, TT
T7 T8
-50...200 °C -50...400 °C
5
2, 3*
0...200 °C 0...400 °C
6, 7, 8
2, 3
5*, 6, 7, 8
2
Thermocouple Design SLSL, TSL
T9 T1*
GLGL, TT
T7 T8
1 x K, 1xJ
-50...200 °C -50...400 °C 0...200 °C 0...400 °C
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9)
n = 5 … 25 mm
Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature)
k = 1 … 10 m
insert diameter 'd' [mm]
5
6
7
8
spring OD [mm]
5
6
7
8
Tip shape: - RTD: standard - T/C: standard (isolated) or grounded (see Appendix - Tip Shapes) Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors) Bayonet: - ø14x1; aluminum or Ni-plated brass (default) - ø12x1, ø15x1, ø18x1, or other on request * Please contact COMECO!
TSBS - G2.G3.G4.G5.G6.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option G2
Code values
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, J - T/C type "J", K - T/C type "K"
G3
Temperature range
T7 - 0…200 °C, T9 - -50…200 °C, T8 - 0…400 °C, T1 - -50…400 °C
G4
Diameter 'd' [mm]
5, 6, 7, 8
G5
Bayonet
12 - ø12x1, 14 - ø14x1, 15 - ø15x1, 18 - ø18x1, Z - other (specify!) (3)
G6
Probe length 'n' [mm]
5…25
G8
Cable length 'k' [m] and type
G10
G11
Sheath material (wetted parts) Accuracy class (1)
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®
RTD
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
T/C
M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
RTD
A - 'A', B - 'B', C - '2xB'
T/C
1 - '1' (3), 2 - '2' 2, 3 (3)
G12
Number of wires
G14
Tip shape (hot junction) (2)
X - standard (isolated from sheath), G - grounded
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface
(1) (2) (3)
Only for RTD sensors! Only for thermocouples! Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
temperature probes (MI) RTD PROBE FOR HEAD ASSEMBLY
TSECx
Sheath - stainless steel (see Appendix - Sheath materials) Extension wires - Teflon® or glass fiber
SENSITIVE ELEMENT
DIMENSIONS
TEMPERATURE RANGE
n [mm]
d [mm]
wires
Regular Design
DESIGN WITHOUT EXTENSION (TSEC) 1 x Pt (RB,RD,RF,RG)
2(3) x Pt (RB,RD,RF,RG)
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C
1 x Cu (RH, RK)
T9
-50...200 °C
2 x Cu (RH, RK)
T9
-50...200 °C
T12
-50...100 °C
1 x PTC (RP, RQ)
EXTENDED DESIGN WITH MOVABLE CONNECTION (TSEC2)
DESIGN WITH ADJUSTABLE CONNECTION (TSEC3)
DESIGN WITH GLAND-TYPE CONNECTION (TSEC4)
2 x Pt (RB,RD,RF,RG)
T9 T1 T24 T11 T2 T4 T22
50…1500
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C
2, 3* 2, 3, 4*
50…3000 8, 10, 12, 14, 16, 20
2, 3, 4
6*, 8, 10
2x2(3)*
12, 14, 16, 20
2x2(3), 3x2
50…3000 50…1500
6
2, 3, 4*
50…3000 8, 10, 12, 14, 16, 20 50…3000
50…1500 50…3000 50…3000 MI Design
2 x PTC (RP, RQ)
1 x Pt (RB,RD,RF,RG)
4 5 6
50…500
8, 10 12, 14, 16, 20 6 8, 10, 12, 14 8, 10, 12, 14
2x2 2x2(3)*
3*
2, 3*
2x2
4.5
2, 3*
6
2, 3, 4*
8
2, 3, 4
6, 8
2x2, 2x3*
50...50000
50...50000
2, 3
Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Head connection 'GH': - M10x1(Q20), M12x1.5(Q7), M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2) - 1/4"(Q23/Q24), 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11) - welding Extension length: m = 0…1500 mm (w/o spring-loaded adapter) m = m1...1500 mm (w/ spring-loaded adapter) Extension diameter: (for TSEC1 and TSEC2 only, [mm]) Probe diameter 'd' Ext. length 'm' up to 50 mm 50...150 mm 150...500 mm 500+ mm
3, 4 mm 8 8 10 14
4.5...6 mm d 8 10 14
8 mm d d 10 14
10 mm d d d 14
10+ mm d d d d
Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes) Process pressure: Probe design Max. pressure *
DESIGN WITH NIPPLE-UNION-NIPPLE CONNECTION (TSEC5)
TSEC, TSEC1 25 bar
TSEC4 6 bar
TSEC3, TSEC5 0 bar
Sheath material: 1.4301(M1), 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362(M15) Wire material: Cu, Ni, or Ag Extension wire isolation: Teflon® (T) or glass fiber (GL) Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Spring-loaded adapter: (mounted between probe and protection head)
m1
100...150
GH
20...25
* Please contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
TSEC2 16 bar
m1 = 60…100 mm d ≤ 8 mm
COMECO reserves the right of changing specifications without prior notice!
EXTENDED DESIGN WITH WELDED CONNECTION (TSEC1)
T9 T1 T24 T11 T2 T4 T22
temperature probes
Ordering code
TSEC(1,2,3,4,5) - (MI -) G1G2.G3.G4.G6.G7.G9'9".GH.G10.G11.G12.G13.G14 - #1
Code Feature or option
Code values
G1
Number of RTD sensors
1, 2, or 3 (10)
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP - PTC 1k, RQ - PTC 2k
G3
Temperature range
T1 - -50…400 °C, T2 - -200…600 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C, T22 - -200…200 °C, T24 - -50…500 °C
G4
Diameter 'd' [mm]
G6
Probe length 'n' [mm] (1)
50…50000 (see table overleaf)
G7
Probe length 'm' [mm] (2)
0…1500 (m1…1500 with 'OA' option)
G9'
Mounting connection
X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9"
Compression fitting ferrule (4)
BR - brass, GR - graphite, SS - stainless steel, TF - Teflon®
GH
Head connection
W - welding, Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q6 - G3/4", Q7 - M12x1.5, Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Z - other connection (specify!)
G10
Sheath material (wetted parts)
G11
Accuracy class
X - none (5), A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (10)
(6)
regular design
4, 5, 6, 8, 10, 12, 14, 16, 20
MI design
3 (10), 4.5, 6, 8
regular design MI design
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404), M15 - 1.4362 (10) M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404)
CU - copper (7), NI - nickel, AG - silver (8)
G13
Wire material
G14
Tip shape
X - standard closed, N - narrowed (8), P - pitted (8)
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled) (8), OA - spring-loaded adapter (9), OP - electrochemically polished sheath surface (8)
(1)
'n+m' for TSEC3 and TSEC4! Only for TSEC1, TSEC2, and TSEC5! Only for TSEC! (4) Only for TSEC4! (5) For non-Pt sensors (6) Only for Pt sensors! (7) Not applicable to non-MI (regular) RTDs for above 500 °C! (8) Only for non-MI (regular) design! (9) Only for TSEC, TSEC1, and TSEC5! (10) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes (MI) T/C PROBE FOR HEAD ASSEMBLY
TSECx
Sheath - stainless steel (see Appendix - Sheath materials) Extension wires - Teflon® or glass fiber
SENSITIVE ELEMENT
TEMPERATURE RANGE
1(2) x J 1(2) x L
T4
0...800 °C
1(2) x K
T3 T16 T6*
0...850 °C 0...1100 °C 0...1150 °C
1(2) x E
T3 T13
1(2) x S 1(2) x R
DIMENSIONS n [mm]
d [mm]
wires
50...1500 50...3000
6 8, 10, 12, 14, 16, 20, 22
2 (2x2)
50...1500
6
50...3000
8, 10, 12, 14, 16, 20, 22
0...850 °C 0...1000 °C
50...1500 50...3000
6 8, 10, 12, 14, 16, 20, 22
2 (2x2)
T16 T6*
0...1100 °C 0...1150 °C
50...1500
6
50...3000
8, 10, 12, 14, 16, 20, 22
2 (2x2)
T4
0...800 °C
50...50000
3, 4.5, 6, 8, 10*
T8
0...400 °C
50...50000
3, 4.5, 6, 8, 10*
0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C
50...50000
3, 4.5, 6, 8, 10*
2
2xK 2 x N, 2 x E
T3 T16 T6* T6*
50...50000
3, 4.5, 6, 8, 10*
2x2
2xS 2xR
T16 T6*
0...1100 °C 0...1150 °C
50...10000
3, 4.5, 6
2x2
Regular Design
EXTENDED DESIGN WITH WELDED CONNECTION (TSEC1)
MI Design 1xJ 2xJ 1xT 2xT 1xK 1 x N, 1 x E
EXTENDED DESIGN WITH MOVABLE CONNECTION (TSEC2)
DESIGN WITH ADJUSTABLE CONNECTION (TSEC3)
DESIGN WITH GLAND-TYPE CONNECTION (TSEC4)
2 (2x2)
2 2x2 2 2x2
Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Head connection 'GH': - M10x1(Q20), M12x1.5(Q7), M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2) - 1/4"(Q23/Q24), 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11) - welding Extension length: m = 0…1500 mm (w/o spring-loaded adapter) m = m1...1500 mm (w/ spring-loaded adapter) Extension diameter: (for TSEC1 and TSEC2 only, [mm]) Probe diameter 'd' Ext. length 'm' up to 50 mm 50...150 mm 150...500 mm 500+ mm
3 mm
4.5, 6 mm
8 mm
10 mm
10+ mm
6 8 10 14
d 8 10 14
d d 10 14
d d d 14
d d d d
Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Process pressure: Probe design Max. pressure *
DESIGN WITH NIPPLE-UNION-NIPPLE CONNECTION (TSEC5)
TSEC, TSEC1 25 bar
TSEC4 6 bar
TSEC3, TSEC5 0 bar
Sheath material: 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362 (M15) MI sheath material: 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4876(M7), 2.4816(M8), Nicrobell® (M10) Extension wire isolation: Teflon® (T) or glass fiber (GL) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) Spring-loaded adapter: (mounted between probe and protection head)
m1
100...150
GH
20...25
* Please contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
TSEC2 16 bar
m1 = 60…100 mm d ≤ 8 mm
COMECO reserves the right of changing specifications without prior notice!
DESIGN WITHOUT EXTENSION (TSEC)
temperature probes
Ordering code
TSEC(1,2,3,4,5) - (MI -) G1G2.G3.G4.G6.G7.G9'9".GH.G10.G11.G14 - #1
Code Feature or option G1
Number of thermocouples
G2
Thermocouple
G3
Temperature range
G4
Diameter 'd' [mm]
Code values 1 or 2 regular design
E - type "E", J - type "J", K - type "K", L - type "L", R - type "R", S - type "S"
MI design
E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T" T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (7), T13 - 0…1000 °C, T16 - 0…1100 °C
regular design
6, 8, 10, 12, 14, 16, 20, 22
MI design
3, 4.5, 6, 8, 10
(1)
G6
Probe length 'n' [mm]
G7
Probe length 'm' [mm] (2)
0…1500 (m1…1500 with 'OA' option)
50…50000 (see table overleaf)
G9'
Mounting connection
X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9"
Compression fitting ferrule (4)
BR - brass, GR - graphite, SS - stainless steel, TF - Teflon®
GH
Head connection
W - welding, Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q6 - G3/4", Q7 - M12x1.5, Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Z - other connection (specify!)
G10
Sheath material (wetted parts)
regular design
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762, M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4401 (1.4404), M15 - 1.4362
MI design
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4401 (1.4404), M10 - Nicrobell®
G11
Accuracy class
1 - '1' (7), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
#1
Options
X - none, OA - spring-loaded adapter (5), OP - electrochemically polished sheath surface (6)
(1)
'n+m' for TSEC3 and TSEC4! Only for TSEC1, TSEC2, and TSEC5! Only for TSEC! (4) Only for TSEC4! (5) Only for TSEC, TSEC1, and TSEC5! (6) Only for non-MI (regular) design! (7) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
ANGLED PROBE WITH SCREW FIXING
TSG
Sheath - stainless steel (see table notes) Cable - see table notes
SENSITIVE ELEMENT 1 x Pt (RB,RD,RF,RG) 1 x K, 1 x J, 1xT
n = 10 ... 30 mm k = 1 ... 10 m
CABLE TYPE GLGL
TEMPERATURE RANGE T8 T7
0...400 °C 0...200 °C
SLSL, TSL
T9
-50...200 °C
TT
T7
YY, UU, YU
T10 T12
DIMENSIONS d [mm]
wires
4*, 5
2, 3*
6
2, 3
5, 6
2
0...200 °C -10...60 °C -50...100 °C
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Tip shape: - RTD: standard - T/C: standard (isolated) or grounded (see Appendix - Tip Shapes)
□
8x8
10x10
Lmin
7
9
d
4, 5
4, 5, 6
Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors) * Please contact COMECO!
TSG - G2.G3.G4.G5.G6.G7.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option G2
Code values
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, J - T/C type "J", K - T/C type "K", T - T/C type "T"
G3
Temperature range
T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T10 - -10…60 °C, T12 - -50…100 °C
G4
Diameter 'd' [mm]
4, 5, 6
G5
Dimension '□'
8 - 8x8 mm, 10 - 10x10 mm
G6
Probe length 'n' [mm]
10…30
G7
Dimension 'L' [mm]
7…20
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (3), 1PV…10PV - PVC
G10
Sheath material
G11 G12 G14
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
Accuracy class Number of wires
(1)
Tip shape (hot junction)
RTD
A - 'A', B - 'B', C - '2xB'
T/C
1 - '1' (3), 2 - '2' 2, 3
(2)
X - standard (isolated from sheath), G - grounded
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface
(1)
Only for RTD sensors! Only for thermocouples! (3) Contact COMECO! (2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
temperature probes
PENETRATION RTD PROBE WITH HANDLE
TSIx
SENSITIVE ELEMENT
Sheath - stainless steel (see table notes) Cable and handle - see table notes DESIGN WITH SILICONE HANDLE (TSI1)
TEMPERATURE RANGE
1 x Pt (RB,RD,RF,RG)
T9
2 x Pt (RB,RD,RF,RG)
k = 1 … 10 m
T9
DIMENSIONS d [mm]
-50...200 °C
-50...200 °C
wires
4, 5
2, 3*
6
2, 3, 4*
8
2, 3, 4
5, 6
2x2
8
2, 3*
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Cable type: - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature)
DESIGN WITH PLASTIC HANDLE (TSI2)
Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Handle type: - silicone (TSI1) - glass-filed plastic (TSI2) - stainless steel 1.4301 (TSI3)
k = 1 … 10 m
DESIGN WITH ROBUST METAL HANDLE (TSI3)
Filling: thermal conductive paste Cable connector: 4-pin (C3) (see Appendix - Connectors) Dimension limits: Model d=4
TSI1, TSI2 n = 50...200
TSI3 n = 50...200
d=5
n = 50...300
n = 50...300
d=6
n = 50...500
n = 50...500
d=8
-
n = 50...800
k = 1 … 10 m * Please contact COMECO!
Ordering code
TSI(1,2,3) - G1G2.G4.G6.G8.G10.G11.G12.G15 - #1 Code values
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000
G4
Diameter 'd' [mm]
4, 5, 6, 8
G6
Probe length 'n' [mm]
50…500
G8
Cable length 'k' [m] and type
1SL…10SL - silicone, 1TF…10TF - Teflon® (1)
G10
Sheath material (wetted parts)
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
(1)
G11
Accuracy class
G12
Number of wires
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only)
#1
Options
X - none, OP - electrochemically polished sheath surface
(1)
A - 'A', B - 'B', C - '2xB' 2, 3 (1), 4 (1)
Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Code Feature or option
temperature probes
(MI) HAND-HELD PROBE WITH CONNECTOR
TSHx
DIMENSIONS SENSITIVE ELEMENT
Sheath - see table Cable - see table notes Connector - see table notes
SHEATH MATERIAL
TEMPERATURE RANGE
d [mm]
wires
RTD Design
DESIGN WITH PLASTIC HANDLE (TSH)
1 x Pt (RB,RD,RF,RG)
M1, M2, M3, M9
1 x Cu (RH, RK)
T7 T8 T1* T7
0...200 °C 0...400 °C -50...400 °C
4, 5
2, 3*
6
2, 3, 4*
0...200 °C
5*, 6
2, 3, 4*
5, 6
2
1, 1.5, 2, 3, 4.5, 6, 8, 10
2
1, 1.5, 2, 3, 4.5, 6, 8
2
Regular Thermocouple Design 1 x K, 1 x J,
M2, M3, M9
1xT n = 200 ... 2 000 mm
d ≤ 6 mm
T7
0...200 °C
T8
0...400 °C
MI Thermocouple Design
k = 1 … 10 m
M2, M3, M8 1 x J, 1 x T **
M9, M5
T4
0...800 °C
M4
DESIGN WITH ROBUST METAL HANDLE (TSHN)
M2, M3 T3
0...850 °C
M9 1 x K, 1 x N, n = 200 ... 2 000 mm
k = 1 … 10 m
6, 8
2
3, 4.5, 6
2
1, 1.5, 2, 3, 4.5, 6, 8, 10
2
1, 1.5, 2, 3, 4.5, 6, 8
2
M10
1 x E **
M7*
3, 6, 10
2
T16
0...1100 °C
1, 1.5, 2, 3, 4.5, 6, 8, 10
2
6, 8
2
T6
0...1150 °C
1.5, 3, 4.5, 6, 8
2
M10
T6
0...1250 °C
3, 4.5, 6
2
M8
T16
0...1100 °C
3, 4.5, 6
2
M8 M4 M5
1 x S(R)
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4762 (M4), 1.4841 (M5), 1.4876 (M7), 2.4816 (M8), 1.4404 (M9), Nicrobell® (M10)
Tip shape: - RTD: standard, narrowed, pitted - T/C: standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors) * Please contact COMECO! ** For T/C type "T": (T8) 0...400 °C; for T/C type "E": (T13) 0...1000 °C
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature)
temperature probes
Ordering code
TSH(N) - (MI-) G2.G3.G4.G6.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option G2
G3
G4
Code values regular design
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, J - T/C type "J", K - T/C type "K", T - T/C type "T"
MI design
E - T/C type "E", J - T/C type "J", K - T/C type "K", N - T/C type "N", R - T/C type "R", S - T/C type "S", T - T/C type "T"
Sensor
T1 - -50…400 °C, T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1150(1250) °C, T7 - 0…200 °C, T8 - 0…400 °C, T16 - 0…1100 °C
Temperature range
Diameter 'd' [mm]
RTD
4, 5, 6, 8
regular T/C design
5, 6
MI T/C design
1, 1.5, 2, 3, 4.5, 6, 8, 10
G6
Probe length 'n' [mm]
G8
Cable length 'k' [m] and type
G10
G11
Sheath material (wetted parts)
Accuracy class
200…2000 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®
RTD
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
regular T/C design
M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
MI T/C design
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®
RTD
X - none (1), A - 'A', B - 'B', C - '2xB'
T/C
1 - '1' (5), 2 - '2'
(2)
2, 3, 4 (5)
G12
Number of wires
G14
Tip shape
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled) (4), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface (4)
RTD
X - standard closed, N - narrowed, P - pitted
T/C
X - standard (isolated from sheath) (3), G - grounded, E - exposed hot junction (3), O - open-tube design (3)
(1)
For non-Pt sensors Only for RTD sensors! (3) Not available when d = 1! (4) Only for non-MI (regular) design! (5) Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
MAGNETIC PROBE FOR SURFACE MEASUREMENT
TSM
Design - pawn-type plastic body w/ permanent magnet ring Cable - see table notes
SENSITIVE ELEMENT 1 x Pt (RB,RD,RF,RG) 1 x K, 1xJ
CABLE TYPE
TEMPERATURE RANGE
WIRES
SLFSL, TFT
T7** T9**
0...200 °C -50...200 °C
2, 3*
YFY
T10 T12 T19
-10...60 °C -50...100 °C 0...100 °C
2
1xT
2
Sheath material: PPS plastic, magnet ring w/ ferrous metal jacket Cable type: - SLFSL or TFSL (silicone w/ copper shield, max. 250 °C ambient temperature) - TFT (Teflon® w/ copper shield, max. 250 °C ambient temperature) - YFY (PVC w/ copper shield, max. 105 °C ambient temperature) k = 1 ... 10 m Tip shape: - RTD: standard - T/C: grounded (see Appendix - Tip Shapes) Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors) * Please contact COMECO! ** Up to 250 °C (short-term)
TSM - G2.G3.G8.G11.G12.G15 - #1
Code Feature or option
Code values
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, J - T/C type "J", K - T/C type "K", T - T/C type "T"
G3
Temperature range
T7 - 0…200(250) °C, T9 - -50…200(250) °C, T10 - -10…60 °C, T12 - -50…100 °C, T19 - 0…100 °C
G8
Cable length 'k' [m] and type
G11
Accuracy class (1)
1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PV…10PV - PVC
RTD
A - 'A', B - 'B', C - '2xB'
T/C
1 - '1' (2), 2 - '2' 2, 3 (2)
G12
Number of wires
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OB - braid termination lead (only w/o connector)
(1) (2)
Only for RTD sensors! Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
temperature probes
MAGNETIC THERMOCOUPLE PROBE FOR SURFACE MEASUREMENT
TSMS
Design - SS body w/ chromium plated magnet holder and T/C spring Extension cable - see table notes
SENSITIVE ELEMENT
CABLE TYPE
TEMPERATURE RANGE
WIRE [mm]
1 x K, 1 x J,
GLGLP, GLGLV
T8*
0...350 °C
0.5
1xN Sheath material: magnet holder: Cr-plated black steel sensor body: stainless steel w/ ceramic isolator
k = 1 ... 10 m
Cable type: GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) Tip shape: exposed hot junction, flat-surfaced (see Appendix - Tip Shapes) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) Thermocouple connector: 'standard' (C5) or 'miniature' (C6) (see Appendix - Connectors)
* up to 400 °C for short-term use
Ordering code
TSMS - G2.G8.G11.G15 - #1
Code Feature or option G2
Thermocouple
Code values J - type "J", K - type "K", N - type "N"
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber
G11
Accuracy class
1 - '1' (1), 2 - '2'
G15
Connector
X - none, C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector)
Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(1)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
MINERAL-INSULATED RTD PROBE
TSNx
Sheath - see table Extension cable - see table notes
MI CABLE PROBE ONLY (TSN)
SENSITIVE ELEMENT
SHEATH TEMPERATURE MATERIAL RANGE **
1 x Pt (RB,RD,RF,RG)
M1, M2, M3, M5, M8, M9
2 x Pt (RB,RD,RF,RG)
M1, M2, M3, M5, M8, M9
d
n
T7 T8 T9 T22 T1 T11 T4
0...200 °C 0...400 °C -50...200 °C -200...200 °C -50...400 °C -50...600 °C 0...800 °C
DIMENSIONS d [mm]
wires
3*, 4.5, 6, 8
2, 3, 4*
4.5*, 6, 8
2x2 2x3*
n = 50 ... 50 000 mm Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4841 (M5), 2.4816 (M8), 1.4404 (M9)
DESIGN WITH EXTENSION CABLE (TSNA)
Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature ***) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature ***) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Tip shape: standard or narrowed * (see Appendix - Tip Shapes)
n = 50 ... 50 000 mm k = 1 … 10 m
d D
3 6
4.5 6
6 8
8 d
Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Cable connector: 4-pin (C3) (see Appendix - Connectors)
DESIGN WITH CONNECTOR (TSNH)
Temperature limitation: The temperature around TSNA holding tube and TSNH(A) connector must not exceed -50...200 °C!
n = 50 ... 50 000 mm
DESIGN WITH CONNECTOR AND EXTENSION CABLE (TSNHA)
n
k
~ 60
d
* Please contact COMECO! n = 50 ... 50 000 mm
d ≤ 6 mm
k = 1 … 10 m
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
** Max. 550 °C (for chip RTD) or 800 °C (for wire-wound RTD) *** Sub-zero temperatures are not recommended
COMECO reserves the right of changing specifications without prior notice!
d ≤ 6 mm
temperature probes
Ordering code
TSN(A,H,HA) - G1G2.G3.G4.G6.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option
Code values
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000
G3
Temperature range
T7 - 0…200 °C, T9 - -50…200 °C, T22 - 200…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T11 - 50…600 °C (4), T4 - 0…800 °C (4)
G4
Diameter 'd' [mm] (1)
3 (4), 4.5, 6, 8
G6
Probe length 'n' [mm]
50…50000
G8
Cable length 'k' [m] and type
X - no cable, 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1PV…10PV - PVC
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404
G11
Accuracy class
A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (4)
G14
Tip shape
X - standard (isolated from sheath), N - narrowed (2,4)
G15
Connector
#1
Options
(3)
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only) X - none, OS - cable protection SS spring (≈ 50 mm) (3), OB - braid termination lead (only w/o connector) (3)
(1)
Up to 6 mm for TSNH and TSNHA Only for TSN! Only for TSNA and TSNHA! (4) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
MINERAL-INSULATED THERMOCOUPLE PROBE
TSNx SENSITIVE ELEMENT
Sheath - see table Extension cable - see table notes
SHEATH MATERIAL M1
1 x J,
MI CABLE PROBE ONLY (TSN)
1 x T **
TEMPERATURE RANGE max. 400 °C
M2,M3,M9,M5,M8 M4
d [mm] 1, 1.5, 2, 3, 4.5, 6, 8, 10*
max. 800 °C
6, 8
M10 2xJ 2 x T **
n = 50 ... 50 000 mm 1 x K, 1 x N, 1 x E **
DESIGN WITH EXTENSION CABLE (TSNA)
M1 M2,M3,M9,M5,M8 M4 M2, M3, M9
max. 850 °C
M8 M4
2xK
M7*
2xN
M8 M4 M5
n = 50 ... 50 000 mm k = 1 … 10 m
d D
<6 6
6 8
8, 10 d
DESIGN WITH CONNECTOR (TSNH)
6, 8 1, 1.5, 2, 3, 4.5, 6, 8, 10*
M7*
M2, M3, M9
2 x S(R)
1.5, 2, 3, 4.5, 6, 8, 10*
max. 800 °C max. 400 °C
M10
1 x S(R),
max. 400 °C
M1
M5
2 x E **
3, 4.5, 6
M8
3, 6, 10* max. 1100 °C
max. 1150 °C
1, 1.5, 2, 3, 4.5, 6, 8, 10* 6, 8 1.5, 3, 4.5, 6, 8
max. 1250 °C
3, 4.5, 6
max. 850 °C
1.5, 3, 4.5, 6, 8
max. 1100 °C max. 1150 °C
3, 6, 10* 1.5, 3, 4.5, 6, 8 6, 8 1.5, 3, 4.5, 6, 8
max. 1100 °C
3, 4.5, 6
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4762 (M4), 1.4841 (M5), 1.4876 (M7), 2.4816 (M8), 1.4404 (M9), Nicrobell® (M10) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes)
n = 50 ... 50 000 mm
DESIGN WITH CONNECTOR AND EXTENSION CABLE (TSNHA)
Thermocouple connector: 'standard' (C5) or 'miniature' (C6) (see Appendix - Connectors) Temperature limitation: The temperature around TSNA holding tube and TSNH(A) connector must not exceed -50...200 °C!
n = 50 ... 50 000 mm
d ≤ 6 mm
k = 1 … 10 m
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
* Please contact COMECO! ** For T/C type "T": max. 400 °C; for T/C type "E": max. 1000 °C
COMECO reserves the right of changing specifications without prior notice!
Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)
d ≤ 6 mm
temperature probes
Ordering code
TSN(A,H,HA) - G1G2.G3.G4.G6.G8.G10.G11.G14.G15 - #1
Code Feature or option
Code values
G1
Number of thermocouples
1 or 2 (1)
G2
Thermocouple
E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T"
G3
Temperature range
T7 - 0…200 °C, T9 - -50…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T4 - 0…800 °C, T3 - 0…850 °C, T16 - 0…1100 °C, T6 - 0…1150(1250) °C
G4
Diameter 'd' [mm] (2)
1 (3), 1.5 (4), 2, 3, 4.5, 6, 8, 10
G6
Probe length 'n' [mm]
50…50000
G8
Cable length 'k' [m] and type
X - no cable, 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®
G11
Accuracy class
1 - '1' (6), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
G15
Connector (5)
X - none, C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OS - cable protection SS spring (≈ 50 mm) (5), OB - braid termination lead (only w/o connector) (5)
(1)
Only for TSN. Ask for TSNA! Up to 6 mm for TSNH and TSNHA Always grounded (4) Grounded when G1="2" (5) Only for TSNA and TSNHA! (6) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
MINERAL-INSULATED RTD PROBE
TSNx
Sheath - see table Extension cable - see table notes
MI CABLE PROBE ONLY (TSN)
SENSITIVE ELEMENT
SHEATH TEMPERATURE MATERIAL RANGE **
1 x Pt (RB,RD,RF,RG)
M1, M2, M3, M5, M8, M9
2 x Pt (RB,RD,RF,RG)
M1, M2, M3, M5, M8, M9
d
n
T7 T8 T9 T22 T1 T11 T4
0...200 °C 0...400 °C -50...200 °C -200...200 °C -50...400 °C -50...600 °C 0...800 °C
DIMENSIONS d [mm]
wires
3*, 4.5, 6, 8
2, 3, 4*
4.5*, 6, 8
2x2 2x3*
n = 50 ... 50 000 mm Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4841 (M5), 2.4816 (M8), 1.4404 (M9)
DESIGN WITH EXTENSION CABLE (TSNA)
Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature ***) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature ***) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Tip shape: standard or narrowed * (see Appendix - Tip Shapes)
n = 50 ... 50 000 mm k = 1 … 10 m
d D
3 6
4.5 6
6 8
8 d
Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Cable connector: 4-pin (C3) (see Appendix - Connectors)
DESIGN WITH CONNECTOR (TSNH)
Temperature limitation: The temperature around TSNA holding tube and TSNH(A) connector must not exceed -50...200 °C!
n = 50 ... 50 000 mm
DESIGN WITH CONNECTOR AND EXTENSION CABLE (TSNHA)
n
k
~ 60
d
* Please contact COMECO! n = 50 ... 50 000 mm
d ≤ 6 mm
k = 1 … 10 m
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
** Max. 550 °C (for chip RTD) or 800 °C (for wire-wound RTD) *** Sub-zero temperatures are not recommended
COMECO reserves the right of changing specifications without prior notice!
d ≤ 6 mm
temperature probes
Ordering code
TSN(A,H,HA) - G1G2.G3.G4.G6.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option
Code values
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000
G3
Temperature range
T7 - 0…200 °C, T9 - -50…200 °C, T22 - 200…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T11 - 50…600 °C (4), T4 - 0…800 °C (4)
G4
Diameter 'd' [mm] (1)
3 (4), 4.5, 6, 8
G6
Probe length 'n' [mm]
50…50000
G8
Cable length 'k' [m] and type
X - no cable, 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1PV…10PV - PVC
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404
G11
Accuracy class
A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (4)
G14
Tip shape
X - standard (isolated from sheath), N - narrowed (2,4)
G15
Connector
#1
Options
(3)
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only) X - none, OS - cable protection SS spring (≈ 50 mm) (3), OB - braid termination lead (only w/o connector) (3)
(1)
Up to 6 mm for TSNH and TSNHA Only for TSN! Only for TSNA and TSNHA! (4) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
MINERAL-INSULATED THERMOCOUPLE PROBE
TSNx SENSITIVE ELEMENT
Sheath - see table Extension cable - see table notes
SHEATH MATERIAL M1
1 x J,
MI CABLE PROBE ONLY (TSN)
1 x T **
TEMPERATURE RANGE max. 400 °C
M2,M3,M9,M5,M8 M4
d [mm] 1, 1.5, 2, 3, 4.5, 6, 8, 10*
max. 800 °C
6, 8
M10 2xJ 2 x T **
n = 50 ... 50 000 mm 1 x K, 1 x N, 1 x E **
DESIGN WITH EXTENSION CABLE (TSNA)
M1 M2,M3,M9,M5,M8 M4 M2, M3, M9
max. 850 °C
M8 M4
2xK
M7*
2xN
M8 M4 M5
n = 50 ... 50 000 mm k = 1 … 10 m
d D
<6 6
6 8
8, 10 d
DESIGN WITH CONNECTOR (TSNH)
6, 8 1, 1.5, 2, 3, 4.5, 6, 8, 10*
M7*
M2, M3, M9
2 x S(R)
1.5, 2, 3, 4.5, 6, 8, 10*
max. 800 °C max. 400 °C
M10
1 x S(R),
max. 400 °C
M1
M5
2 x E **
3, 4.5, 6
M8
3, 6, 10* max. 1100 °C
max. 1150 °C
1, 1.5, 2, 3, 4.5, 6, 8, 10* 6, 8 1.5, 3, 4.5, 6, 8
max. 1250 °C
3, 4.5, 6
max. 850 °C
1.5, 3, 4.5, 6, 8
max. 1100 °C max. 1150 °C
3, 6, 10* 1.5, 3, 4.5, 6, 8 6, 8 1.5, 3, 4.5, 6, 8
max. 1100 °C
3, 4.5, 6
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4762 (M4), 1.4841 (M5), 1.4876 (M7), 2.4816 (M8), 1.4404 (M9), Nicrobell® (M10) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes)
n = 50 ... 50 000 mm
DESIGN WITH CONNECTOR AND EXTENSION CABLE (TSNHA)
Thermocouple connector: 'standard' (C5) or 'miniature' (C6) (see Appendix - Connectors) Temperature limitation: The temperature around TSNA holding tube and TSNH(A) connector must not exceed -50...200 °C!
n = 50 ... 50 000 mm
d ≤ 6 mm
k = 1 … 10 m
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
* Please contact COMECO! ** For T/C type "T": max. 400 °C; for T/C type "E": max. 1000 °C
COMECO reserves the right of changing specifications without prior notice!
Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)
d ≤ 6 mm
temperature probes
Ordering code
TSN(A,H,HA) - G1G2.G3.G4.G6.G8.G10.G11.G14.G15 - #1
Code Feature or option
Code values
G1
Number of thermocouples
1 or 2 (1)
G2
Thermocouple
E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T"
G3
Temperature range
T7 - 0…200 °C, T9 - -50…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T4 - 0…800 °C, T3 - 0…850 °C, T16 - 0…1100 °C, T6 - 0…1150(1250) °C
G4
Diameter 'd' [mm] (2)
1 (3), 1.5 (4), 2, 3, 4.5, 6, 8, 10
G6
Probe length 'n' [mm]
50…50000
G8
Cable length 'k' [m] and type
X - no cable, 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®
G11
Accuracy class
1 - '1' (6), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
G15
Connector (5)
X - none, C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OS - cable protection SS spring (≈ 50 mm) (5), OB - braid termination lead (only w/o connector) (5)
(1)
Only for TSN. Ask for TSNA! Up to 6 mm for TSNH and TSNHA Always grounded (4) Grounded when G1="2" (5) Only for TSNA and TSNHA! (6) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
MINERAL-INSULATED RTD PROBE
TSNx
Sheath - see table Extension cable - see table notes
MI CABLE PROBE ONLY (TSN)
SENSITIVE ELEMENT
SHEATH TEMPERATURE MATERIAL RANGE **
1 x Pt (RB,RD,RF,RG)
M1, M2, M3, M5, M8, M9
2 x Pt (RB,RD,RF,RG)
M1, M2, M3, M5, M8, M9
d
n
T7 T8 T9 T22 T1 T11 T4
0...200 °C 0...400 °C -50...200 °C -200...200 °C -50...400 °C -50...600 °C 0...800 °C
DIMENSIONS d [mm]
wires
3*, 4.5, 6, 8
2, 3, 4*
4.5*, 6, 8
2x2 2x3*
n = 50 ... 50 000 mm Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4841 (M5), 2.4816 (M8), 1.4404 (M9)
DESIGN WITH EXTENSION CABLE (TSNA)
Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature ***) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature ***) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Tip shape: standard or narrowed * (see Appendix - Tip Shapes)
n = 50 ... 50 000 mm k = 1 … 10 m
d D
3 6
4.5 6
6 8
8 d
Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Cable connector: 4-pin (C3) (see Appendix - Connectors)
DESIGN WITH CONNECTOR (TSNH)
Temperature limitation: The temperature around TSNA holding tube and TSNH(A) connector must not exceed -50...200 °C!
n = 50 ... 50 000 mm
DESIGN WITH CONNECTOR AND EXTENSION CABLE (TSNHA)
n
k
~ 60
d
* Please contact COMECO! n = 50 ... 50 000 mm
d ≤ 6 mm
k = 1 … 10 m
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
** Max. 550 °C (for chip RTD) or 800 °C (for wire-wound RTD) *** Sub-zero temperatures are not recommended
COMECO reserves the right of changing specifications without prior notice!
d ≤ 6 mm
temperature probes
Ordering code
TSN(A,H,HA) - G1G2.G3.G4.G6.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option
Code values
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000
G3
Temperature range
T7 - 0…200 °C, T9 - -50…200 °C, T22 - 200…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T11 - 50…600 °C (4), T4 - 0…800 °C (4)
G4
Diameter 'd' [mm] (1)
3 (4), 4.5, 6, 8
G6
Probe length 'n' [mm]
50…50000
G8
Cable length 'k' [m] and type
X - no cable, 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1PV…10PV - PVC
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404
G11
Accuracy class
A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (4)
G14
Tip shape
X - standard (isolated from sheath), N - narrowed (2,4)
G15
Connector
#1
Options
(3)
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only) X - none, OS - cable protection SS spring (≈ 50 mm) (3), OB - braid termination lead (only w/o connector) (3)
(1)
Up to 6 mm for TSNH and TSNHA Only for TSN! Only for TSNA and TSNHA! (4) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
MINERAL-INSULATED THERMOCOUPLE PROBE
TSNx SENSITIVE ELEMENT
Sheath - see table Extension cable - see table notes
SHEATH MATERIAL M1
1 x J,
MI CABLE PROBE ONLY (TSN)
1 x T **
TEMPERATURE RANGE max. 400 °C
M2,M3,M9,M5,M8 M4
d [mm] 1, 1.5, 2, 3, 4.5, 6, 8, 10*
max. 800 °C
6, 8
M10 2xJ 2 x T **
n = 50 ... 50 000 mm 1 x K, 1 x N, 1 x E **
DESIGN WITH EXTENSION CABLE (TSNA)
M1 M2,M3,M9,M5,M8 M4 M2, M3, M9
max. 850 °C
M8 M4
2xK
M7*
2xN
M8 M4 M5
n = 50 ... 50 000 mm k = 1 … 10 m
d D
<6 6
6 8
8, 10 d
DESIGN WITH CONNECTOR (TSNH)
6, 8 1, 1.5, 2, 3, 4.5, 6, 8, 10*
M7*
M2, M3, M9
2 x S(R)
1.5, 2, 3, 4.5, 6, 8, 10*
max. 800 °C max. 400 °C
M10
1 x S(R),
max. 400 °C
M1
M5
2 x E **
3, 4.5, 6
M8
3, 6, 10* max. 1100 °C
max. 1150 °C
1, 1.5, 2, 3, 4.5, 6, 8, 10* 6, 8 1.5, 3, 4.5, 6, 8
max. 1250 °C
3, 4.5, 6
max. 850 °C
1.5, 3, 4.5, 6, 8
max. 1100 °C max. 1150 °C
3, 6, 10* 1.5, 3, 4.5, 6, 8 6, 8 1.5, 3, 4.5, 6, 8
max. 1100 °C
3, 4.5, 6
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4762 (M4), 1.4841 (M5), 1.4876 (M7), 2.4816 (M8), 1.4404 (M9), Nicrobell® (M10) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes)
n = 50 ... 50 000 mm
DESIGN WITH CONNECTOR AND EXTENSION CABLE (TSNHA)
Thermocouple connector: 'standard' (C5) or 'miniature' (C6) (see Appendix - Connectors) Temperature limitation: The temperature around TSNA holding tube and TSNH(A) connector must not exceed -50...200 °C!
n = 50 ... 50 000 mm
d ≤ 6 mm
k = 1 … 10 m
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
* Please contact COMECO! ** For T/C type "T": max. 400 °C; for T/C type "E": max. 1000 °C
COMECO reserves the right of changing specifications without prior notice!
Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)
d ≤ 6 mm
temperature probes
Ordering code
TSN(A,H,HA) - G1G2.G3.G4.G6.G8.G10.G11.G14.G15 - #1
Code Feature or option
Code values
G1
Number of thermocouples
1 or 2 (1)
G2
Thermocouple
E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T"
G3
Temperature range
T7 - 0…200 °C, T9 - -50…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T4 - 0…800 °C, T3 - 0…850 °C, T16 - 0…1100 °C, T6 - 0…1150(1250) °C
G4
Diameter 'd' [mm] (2)
1 (3), 1.5 (4), 2, 3, 4.5, 6, 8, 10
G6
Probe length 'n' [mm]
50…50000
G8
Cable length 'k' [m] and type
X - no cable, 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®
G11
Accuracy class
1 - '1' (6), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
G15
Connector
(5)
#1
Options
X - none, C5 - T/C connector, C6 - miniature T/C connector X - none, OS - cable protection SS spring (≈ 50 mm) (5), OB - braid termination lead (only w/o connector) (5)
(1)
Only for TSN. Ask for TSNA! Up to 6 mm for TSNH and TSNHA (3) Always grounded (4) Grounded when G1="2" (5) Only for TSNA and TSNHA! (6) Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
MINERAL-INSULATED RTD PROBE
TSNx
Sheath - see table Extension cable - see table notes
MI CABLE PROBE ONLY (TSN)
SENSITIVE ELEMENT
SHEATH TEMPERATURE MATERIAL RANGE **
1 x Pt (RB,RD,RF,RG)
M1, M2, M3, M5, M8, M9
2 x Pt (RB,RD,RF,RG)
M1, M2, M3, M5, M8, M9
d
n
T7 T8 T9 T22 T1 T11 T4
0...200 °C 0...400 °C -50...200 °C -200...200 °C -50...400 °C -50...600 °C 0...800 °C
DIMENSIONS d [mm]
wires
3*, 4.5, 6, 8
2, 3, 4*
4.5*, 6, 8
2x2 2x3*
n = 50 ... 50 000 mm Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4841 (M5), 2.4816 (M8), 1.4404 (M9)
DESIGN WITH EXTENSION CABLE (TSNA)
Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature ***) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature ***) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Tip shape: standard or narrowed * (see Appendix - Tip Shapes)
n = 50 ... 50 000 mm k = 1 … 10 m
d D
3 6
4.5 6
6 8
8 d
Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Cable connector: 4-pin (C3) (see Appendix - Connectors)
DESIGN WITH CONNECTOR (TSNH)
Temperature limitation: The temperature around TSNA holding tube and TSNH(A) connector must not exceed -50...200 °C!
n = 50 ... 50 000 mm
DESIGN WITH CONNECTOR AND EXTENSION CABLE (TSNHA)
n
k
~ 60
d
* Please contact COMECO! n = 50 ... 50 000 mm
d ≤ 6 mm
k = 1 … 10 m
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
** Max. 550 °C (for chip RTD) or 800 °C (for wire-wound RTD) *** Sub-zero temperatures are not recommended
COMECO reserves the right of changing specifications without prior notice!
d ≤ 6 mm
temperature probes
Ordering code
TSN(A,H,HA) - G1G2.G3.G4.G6.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option
Code values
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000
G3
Temperature range
T7 - 0…200 °C, T9 - -50…200 °C, T22 - 200…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T11 - 50…600 °C (4), T4 - 0…800 °C (4)
G4
Diameter 'd' [mm] (1)
3 (4), 4.5, 6, 8
G6
Probe length 'n' [mm]
50…50000
G8
Cable length 'k' [m] and type
X - no cable, 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1PV…10PV - PVC
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404
G11
Accuracy class
A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (4)
G14
Tip shape
X - standard (isolated from sheath), N - narrowed (2,4)
G15
Connector
#1
Options
(3)
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only) X - none, OS - cable protection SS spring (≈ 50 mm) (3), OB - braid termination lead (only w/o connector) (3)
(1)
Up to 6 mm for TSNH and TSNHA Only for TSN! Only for TSNA and TSNHA! (4) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
MINERAL-INSULATED THERMOCOUPLE PROBE
TSNx SENSITIVE ELEMENT
Sheath - see table Extension cable - see table notes
SHEATH MATERIAL M1
1 x J,
MI CABLE PROBE ONLY (TSN)
1 x T **
TEMPERATURE RANGE max. 400 °C
M2,M3,M9,M5,M8 M4
d [mm] 1, 1.5, 2, 3, 4.5, 6, 8, 10*
max. 800 °C
6, 8
M10 2xJ 2 x T **
n = 50 ... 50 000 mm 1 x K, 1 x N, 1 x E **
DESIGN WITH EXTENSION CABLE (TSNA)
M1 M2,M3,M9,M5,M8 M4 M2, M3, M9
max. 850 °C
M8 M4
2xK
M7*
2xN
M8 M4 M5
n = 50 ... 50 000 mm k = 1 … 10 m
d D
<6 6
6 8
8, 10 d
DESIGN WITH CONNECTOR (TSNH)
6, 8 1, 1.5, 2, 3, 4.5, 6, 8, 10*
M7*
M2, M3, M9
2 x S(R)
1.5, 2, 3, 4.5, 6, 8, 10*
max. 800 °C max. 400 °C
M10
1 x S(R),
max. 400 °C
M1
M5
2 x E **
3, 4.5, 6
M8
3, 6, 10* max. 1100 °C
max. 1150 °C
1, 1.5, 2, 3, 4.5, 6, 8, 10* 6, 8 1.5, 3, 4.5, 6, 8
max. 1250 °C
3, 4.5, 6
max. 850 °C
1.5, 3, 4.5, 6, 8
max. 1100 °C max. 1150 °C
3, 6, 10* 1.5, 3, 4.5, 6, 8 6, 8 1.5, 3, 4.5, 6, 8
max. 1100 °C
3, 4.5, 6
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4762 (M4), 1.4841 (M5), 1.4876 (M7), 2.4816 (M8), 1.4404 (M9), Nicrobell® (M10) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes)
n = 50 ... 50 000 mm
DESIGN WITH CONNECTOR AND EXTENSION CABLE (TSNHA)
Thermocouple connector: 'standard' (C5) or 'miniature' (C6) (see Appendix - Connectors) Temperature limitation: The temperature around TSNA holding tube and TSNH(A) connector must not exceed -50...200 °C!
n = 50 ... 50 000 mm
d ≤ 6 mm
k = 1 … 10 m
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
* Please contact COMECO! ** For T/C type "T": max. 400 °C; for T/C type "E": max. 1000 °C
COMECO reserves the right of changing specifications without prior notice!
Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)
d ≤ 6 mm
temperature probes
Ordering code
TSN(A,H,HA) - G1G2.G3.G4.G6.G8.G10.G11.G14.G15 - #1
Code Feature or option
Code values
G1
Number of thermocouples
1 or 2 (1)
G2
Thermocouple
E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T"
G3
Temperature range
T7 - 0…200 °C, T9 - -50…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T4 - 0…800 °C, T3 - 0…850 °C, T16 - 0…1100 °C, T6 - 0…1150(1250) °C
G4
Diameter 'd' [mm] (2)
1 (3), 1.5 (4), 2, 3, 4.5, 6, 8, 10
G6
Probe length 'n' [mm]
50…50000
G8
Cable length 'k' [m] and type
X - no cable, 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®
G11
Accuracy class
1 - '1' (6), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
G15
Connector (5)
X - none, C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OS - cable protection SS spring (≈ 50 mm) (5), OB - braid termination lead (only w/o connector) (5)
(1)
Only for TSN. Ask for TSNA! Up to 6 mm for TSNH and TSNHA Always grounded (4) Grounded when G1="2" (5) Only for TSNA and TSNHA! (6) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
SCREW-IN MI RTD PROBE
TSNGx
Sheath - see table Extension cable - see table notes
STRAIGHT DESIGN (TSNG)
n = 50 ... 50 000 mm k = 1 … 10 m
EXTENDED DESIGN (TSNG1)
SENSITIVE ELEMENT
SHEATH TEMPERATURE MATERIAL RANGE **
1 x Pt (RB,RD,RF,RG)
M1, M2, M3, M5, M8, M9
2 x Pt (RB,RD,RF,RG)
M1, M2, M3, M5, M8, M9
T7 T8 T9 T22 T1 T11 T4
0...200 °C 0...400 °C -50...200 °C -200...200 °C -50...400 °C -50...600 °C 0...800 °C
DIMENSIONS d [mm]
wires
3*, 4.5, 6, 8
2, 3, 4*
2x2
4.5*, 6, 8
2x3*
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4841 (M5), 2.4816 (M8), 1.4404 (M9) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature ***) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature ***) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Tip shape: standard (see Appendix - Tip Shapes)
n = 50 ... 50 000 mm m = 60 ... 50 000 mm k = 1 … 10 m
Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Cable connector: 4-pin (C3) (see Appendix - Connectors) Temperature limitation: The temperature beyond the HEX body (SW) must not exceed -50...200 °C!
ANGLED DESIGN (TSNGL)
Available threads and HEX sizes:
SW
M6
M8
10
10
M10 1/8" 12(13)
M12 1/4" 14
M14 17
M16 3/8" 19
M18 22
* Please contact COMECO! n = 50 ... 50 000 mm k = 1 … 10 m
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
** Max. 550 °C (for chip RTD) or 800 °C (for wire-wound RTD) *** Sub-zero temperatures are not recommended
M20 1/2" 24
COMECO reserves the right of changing specifications without prior notice!
G
temperature probes
Ordering code
TSNG(G1,L) - G1G2.G3.G4.G6.G7.G8.G9.G10.G11.G12.G15 - #1
Code Feature or option
Code values
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000
G3
Temperature range
T7 - 0…200 °C, T9 - -50…200 °C, T22 - 200…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T11 - 50…600 °C (3), T4 - 0…800 °C (3)
G4
Diameter 'd' [mm]
3 (3), 4.5, 6, 8
G6
Probe length 'n' [mm]
50…50000
G7
Probe length 'm' [mm] (1)
60…50000
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (3), 1PV…10PV - PVC
G9
Mounting connection
Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q7 - M12x1.5, Q8 - M14x1.5, Q10 - 1/2" NPT, Q18 - G1/8", Q19 - 1/8" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Q26 - M8x1, Q29 - M8x1.25, Q30 - M10x1.5, Q31 - M6x1, Uxx - union nut (xx - same as for Qxx)
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404
G11
Accuracy class
A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (3)
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only)
#1
Options
X - none, OS - cable protection SS spring (≈ 50 mm) (2), OB - braid termination lead (only w/o connector)
(1)
Only for TSNG1! Only for TSNG! (3) Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
SCREW-IN MI THERMOCOUPLE PROBE
TSNGx
Sheath - see table Extension cable - see table notes
SENSITIVE ELEMENT
SHEATH MATERIAL
TEMPERATURE RANGE max. 400 °C
M1
STRAIGHT DESIGN (TSNG)
1 x J,
M2,M3,M9,M5,M8
1 x T **
M4
d [mm] 1.5, 2, 3, 4.5, 6, 8, 10*
max. 800 °C
6, 8
M10 max. 400 °C
M1
2xJ
M2,M3,M9,M5,M8
2 x T **
n = 50 ... 50 000 mm k = 1 … 10 m
3, 4.5, 6
max. 800 °C
M4 M1
max. 400 °C
M2, M3, M9
max. 850 °C
6, 8 1.5, 2, 3, 4.5, 6, 8, 10*
M7*
1 x K, 1 x N,
3, 6, 10* max. 1100 °C
M8
1 x E **
M4
EXTENDED DESIGN (TSNG1)
max. 1150 °C
M5 M10 2xK
M7*
2xN
M8
2 x E **
M4
1 x S(R),
3, 4.5, 6 1.5, 3, 4.5, 6, 8
max. 1150 °C
3, 6, 10* 1.5, 3, 4.5, 6, 8 6, 8 1.5, 3, 4.5, 6, 8
max. 1100 °C
M8
2 x S(R)
6, 8 1.5, 3, 4.5, 6, 8
max. 850 °C max. 1100 °C
M5
1.5, 2, 3, 4.5, 6, 8, 10*
max. 1250 °C
M2, M3, M9
n = 50 ... 50 000 mm m = 60 ... 50 000 mm k = 1 … 10 m
1.5, 2, 3, 4.5, 6, 8, 10*
3, 4.5, 6
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4762 (M4), 1.4841 (M5), 1.4876 (M7), 2.4816 (M8), 1.4404 (M9), Nicrobell® (M10) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature)
ANGLED DESIGN (TSNGL)
Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes)
n = 50 ... 50 000 mm k = 1 … 10 m
Thermocouple connector: 'standard' (C5) or 'miniature' (C6) (see Appendix - Connectors) Temperature limitation: The temperature beyond the HEX body (SW) must not exceed -50...200 °C! Available threads and HEX sizes: G SW
M6
M8
10
10
M10 1/8" 12(13)
M12 1/4" 14
M14 17
M16 3/8" 19
M18 22
M20 1/2" 24
* Please contact COMECO! ** For T/C type "T": max. 400 °C; for T/C type "E": max. 1000 °C
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)
temperature probes
Ordering code
TSNG(G1,L) - G1G2.G3.G4.G6.G7.G8.G9.G10.G11.G14.G15 - #1
Code Feature or option
Code values
G1
Number of thermocouples
1 or 2
G2
Thermocouple
E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T"
G3
Temperature range
T7 - 0…200 °C, T9 - -50…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T4 - 0…800 °C, T3 - 0…850 °C, T16 - 0…1100 °C, T6 - 0…1150(1250) °C
G4
Diameter 'd' [mm]
1.5 (1), 2, 3, 4.5, 6, 8
G6
Probe length 'n' [mm]
50…50000
G7
Probe length 'm' [mm] (2)
60…50000
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®
G9
Mounting connection
Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q7 - M12x1.5, Q8 - M14x1.5, Q10 - 1/2" NPT, Q18 - G1/8", Q19 - 1/8" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Q26 - M8x1, Q29 - M8x1.25, Q30 - M10x1.5, Q31 - M6x1, Uxx - union nut (xx - same as for Qxx)
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®
G11
Accuracy class
1 - '1' (4), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
G15
Connector
X - none, C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OS - cable protection SS spring (≈ 50 mm) (3), OB - braid termination lead (only w/o connector)
(1)
Grounded when G1="2" Only for TSNG1! (3) Only for TSNG! (4) Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
(MI**) CLAMP CABLE PROBE FOR PIPE-SURFACE MEASUREMENT
TSTx
DIMENSIONS SENSITIVE ELEMENT
Sheath - stainless steel (see table notes) Clamp - see table notes Cable - see table notes
CABLE TYPE
TEMPERATURE RANGE
d [mm]
wires
RTD Design
STRAIGHT-TUBE DESIGN (TST)
4.5**, 5
2, 3*
6
2, 3, 4*
T7 T8
0...200 °C 0...400 °C
6
2x2
SLSL, TSL, YY, UU, YU
T9
-50...200 °C
GLGL, TT
T7
0...200 °C
SLSL, TSL, YY, UU, YU
T12
-50...100 °C
GLGL, TT
T19
0...100 °C
SLSL, TSL, YY, UU, YU
T9 T1*
2 x Pt (RB,RD,RF,RG)
GLGL, TT
1 x Cu (RH, RK) 2 x Cu (RH, RK) n = 20 … 100 mm D = 17 … 280 mm k = 1 … 10 m
-50...200 °C -50...400 °C
1 x Pt (RB,RD,RF,RG)
1 x PTC (RP, RQ)
5*
2, 3*
6
2, 3, 4*
6
2x2
6
2, 3
5, 6
2
4.5, 6
2
Regular Thermocouple Design
DESIGN WITH ANGLED TERMINATION (TSTL)
1 x J, 1 x K, 1xT
SLSL, TSL, YY, UU, YU
T9 T1*
GLGL, TT
T8
-50...200 °C -50...400 °C 0...400 °C
MI Thermocouple Design ** 1 x N, 1 x E, 1xT
SLSL, TSL, YY, UU, YU
T9 T1*
GLGL, TT
T8
-50...200 °C -50...400 °C 0...400 °C
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature)
Diameter 'D'
Average pipe OD
17...29 mm
22
25...45 mm
35
40...60 mm 63...83 mm
50 73
Tip shape: - RTD: standard - T/C: standard (isolated) or grounded (see Appendix - Tip Shapes) Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance)
78...98 mm
88
93...113 mm
103
108...128 mm
118
123...143 mm
133
138...158 mm 153...173 mm
148 163
168...188 mm
178
17...113 mm
8 mm or 14 mm
183...203 mm
193
108...280 mm
14 mm
198...218 mm
208
213...233 mm 228...248 mm
223 238
243...263 mm
253
258...280 mm
269
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors) Available clamp sizes: Diameter 'D'
Clamp width
- other on request
* Please contact COMECO! ** Available only for TSTL!
COMECO reserves the right of changing specifications without prior notice!
n = 20 … 100 mm D = 17 … 280 mm k = 1 … 10 m
temperature probes
Ordering code
TST(L) - (MI -(1)) G1G2.G3.G4.G5.G6.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option G1 G2
G3 G4
Code values
Number of sensors (3)
1 or 2 regular design
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP -PTC 1k, RQ - PTC 2k, J - T/C type "J", K - T/C type "K", T - T/C type "T"
MI design
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP -PTC 1k, RQ - PTC 2k, E - T/C type "E", N - T/C type "N", T - T/C type "T"
Sensor
T1 - -50…400 °C, T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T12 - 50…100 °C, T19 - 0…100 °C
Temperature range regular design
Diameter 'd' [mm]
MI design
5, 6 4.5, 6
G5
Clamp diameter 'D' (average pipe OD)
22 - 17…29 mm, 35 - 25…45 mm, 50 - 40…60 mm, 73 - 63…83 mm, 88 - 78…98 mm, 103 - 93…113 mm, 118 - 108…128 mm, 133 - 123…143 mm, 148 - 138…158 mm, 163 - 153…173 mm, 178 - 168…188 mm, 193 - 183…203 mm, 208 - 198…218 mm, 223 - 213…233 mm, 238 - 228…248 mm, 253 - 243…263 mm, 269 - 258…280 mm, Z - other on request (specify average pipe OD) (6)
G6
Probe length 'n' [mm]
20…100
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (6), 1PV…10PV - PVC
G10
Sheath material (wetted parts)
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
G11
Accuracy class
G12
Number of wires (3)
RTD
X - none (2), A - 'A', B - 'B', C - '2xB'
T/C
1 - '1' (6), 2 - '2' 2, 3, 4 (6)
(4)
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled) (5), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface (5)
(1)
Available only for TSTL! For non-Pt sensors Only for RTD sensors! (4) Only for thermocouples! (5) Only for non-MI (regular) design! (6) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
TOROIDAL CABLE PROBE
TSTO SENSITIVE ELEMENT
Sheath - stainless steel (see table notes) Cable - see table notes
CABLE TYPE
TEMPERATURE RANGE
DIMENSIONS d [mm]
wires
RTD Design -50...200 °C -50...100 °C
4, 5
2, 3*
6
2, 3, 4*
0...200 °C 0...400 °C
6
2x2
6
2, 3
5, 6
2
1 x Pt (RB,RD,RF,RG)
SLSL, TSL, YY, UU, YU
T9 T12
2 x Pt (RB,RD,RF,RG)
GLGL, TT
T7 T8
SLSL, TSL, YY, UU, YU
T12
-50...100 °C
GLGL, TT
T19
0...100 °C
1 x PTC (RP, RQ)
Thermocouple Design SLSL, TSL, YY, UU, YU
T9
-50...200 °C
1 x J, 1xT
GLGL, TT
T8
0...400 °C
1 x K,
n = 20 … 30 mm D = 8 … 24 mm k = 1 … 10 m
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9)
d [mm]
4
5
6
H [mm]
6
7
8
Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) Tip shape: - RTD: standard - T/C: standard (isolated) or grounded (see Appendix - Tip Shapes) Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors)
COMECO reserves the right of changing specifications without prior notice!
* Please contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
Ordering code
TSTO - G1G2.G3.G4.G5.G6.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option
Code values
G1
Number of sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RP -PTC 1k, RQ - PTC 2k, J - T/C type "J", K - T/C type "K", T - T/C type "T"
G3
Temperature range
T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T12 - 50…100 °C, T19 - 0…100 °C
G4
Diameter 'd' [mm]
4, 5, 6
G5
Toroid diameter 'D' [mm]
8…24
G6
Probe length 'n' [mm]
20…30
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1PV…10PV - PVC
G10
Sheath material (wetted parts)
G11
Accuracy class (2)
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
RTD
X - none (1), A - 'A', B - 'B', C - '2xB'
T/C
1 - '1' (4), 2 - '2' 2, 3, 4 (4)
G12
Number of wires
G14
Tip shape (hot junction) (3)
X - standard (isolated from sheath), G - grounded
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface
(1)
For non-Pt sensors Only for RTD sensors! Only for thermocouples! (4) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
FINGER CABLE PROBE FOR PIPE-SURFACE MEASUREMENT
TSY SENSITIVE ELEMENT
Sheath - stainless steel (see table notes) Cable - see table notes
CABLE TYPE
TEMPERATURE RANGE
WIRES
RTD Design -50...200 °C -50...100 °C
2, 3, 4*
0...200 °C 0...400 °C
2x2
1 x Pt (RB,RD,RF,RG)
SLSL, TSL, YY, UU, YU
T9 T12
2 x Pt (RB,RD,RF,RG)
GLGL, TT
T7 T8
SLSL, TSL, YY, UU, YU
T12
-50...100 °C
GLGL, TT
T19
0...100 °C
1 x PTC (RP, RQ)
2, 3
Thermocouple Design SLSL, TSL, YY, UU, YU
T9
-50...200 °C
1 x J, 1xT
GLGL, TT
T8
0...400 °C
1 x K,
2
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) n = 20 … 30 mm k = 1 … 10 m
Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Tip shape: - RTD: standard - T/C: standard (isolated) or grounded (see Appendix - Tip Shapes) Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors) * Please contact COMECO!
TSY - G1G2.G3.G6.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option
Code values
G1
Number of sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RP -PTC 1k, RQ - PTC 2k, J - T/C type "J", K - T/C type "K", T - T/C type "T"
G3
Temperature range
T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T12 - 50…100 °C, T19 - 0…100 °C
G6
Probe length 'n' [mm]
20…30
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1PV…10PV - PVC
G10
Sheath material (wetted parts)
G11
Accuracy class (2)
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
RTD
X - none (1), A - 'A', B - 'B', C - '2xB'
T/C
1 - '1' (4), 2 - '2' 2, 3, 4 (4)
G12
Number of wires
G14
Tip shape (hot junction) (3)
X - standard (isolated from sheath), G - grounded
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface
(1)
For non-Pt sensors Only for RTD sensors! Only for thermocouples! (4) Contact COMECO! (2) (3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
temperature probes
(MI) RTD REPLACEABLE INSERT - PREPARED FOR IN-HEAD TRANSMITTER ** Sheath - stainless steel (see Appendix - Sheath materials) Terminal base - Al2O3. Terminals - Ni-plated brass
TSSx TSOSx
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
n [mm]
d [mm]
wires
Regular Design
DESIGN WITH TERMINAL BLOCK TYPE "M" (TS(O)SM) 1 x Pt (RB,RD,RF,RG)
2 x Pt (RB,RD,RF,RG) 3 x Pt * (RB,RD,RF,RG) 1 x Cu (RH, RK) 2 x Cu (RH, RK) 1 x PTC (RP, RQ)
T9 T1 T24 T11 T2 T4 T22 T9
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C -50...200 °C
T9
-50...200 °C
T12
-50...100 °C
50…200
4
2
50…500
5
2, 3*
50…1500
6
2, 3, 4*
50…3000
8
2, 3, 4
50…3000
6, 8, 10
2x2, 2x3*
50…3000
8, 10
3x2
50…1500
6
2, 3, 4*
8
2, 3, 4
50…3000 50…3000
2 x PTC (RP, RQ)
6
2x2*
8
2x2(3)*
50…1500
6
50…3000
8, 10
50…3000
8, 10
2, 3 2x2
MI Design 1 x Pt (RB,RD,RF,RG)
DESIGN WITH TERMINAL BLOCK TYPE "B" (TS(O)SB) 2 x Pt (RB,RD,RF,RG)
T9 T1 T24 T11 T2 T4 T22
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C
50...50000
50...50000
3*
2, 3*
4.5
2, 3*
6
2, 3, 4*
8
2, 3, 4
6, 8
2x2, 2x3*
Suitable protection heads: (see Appendix - Protection Heads) - TS(O)SM: heads with 20 mm mounting distance - TS(O)SB: heads with 33 mm mounting distance Fixing to protection head: direct (default) or springing ('OS' option) Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes) Sheath material: 1.4301(M1), 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362 (M15)
Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance)
* Please contact COMECO! ** No transmitter mounted!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Wire material: Cu, Ni, or Ag
temperature probes
Ordering code
TS (B, M) - (MI -) G1G2.G3.G4.G6.G10.G11.G12.G13.G14 - #1
Code Feature or option
Code values
Base model variant
S - standard (w/ terminal block), OS - prepared for in-head transmitter (w/o terminal block)
G1
Number of RTD sensors
1, 2, or 3 (7)
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP - PTC 1k, RQ - PTC 2k
G3
Temperature range
T1 - -50…400 °C, T2 - -200…600 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C, T22 - -200…200 °C, T24 - -50…500 °C
G4
Diameter 'd' [mm]
G6
Insert length 'n' [mm]
regular design
4, 5, 6, 8, 10
MI design
3 (7), 4.5, 6, 8
(1)
50…50000 (see table overleaf) regular design
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404, M15 - 1.4362
G10
Sheath material (wetted parts)
G11
Accuracy class
X - none (2), A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (7)
(3)
MI design
M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
CU - copper (4), NI - nickel, AG - silver (5)
G13
Wire material
G14
Tip shape
X - standard closed, N - narrowed (5), P - pitted (5)
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled) (5,6), OS - spring-fixed terminal block, OP - electrochemically polished sheath surface (5)
(1)
This length does not coincide with the probe immersion length! For non-Pt sensors Only for Pt sensors! (4) Not applicable to non-MI (regular) RTDs for above 500 °C! (5) Only for non-MI (regular) design! (6) Requires 'OS' option! (7) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
(MI) T/C REPLACEABLE INSERT - PREPARED FOR IN-HEAD TRANSMITTER ** Sheath - stainless steel (see Appendix - Sheath materials) Terminal base - Al2O3. Terminals - Ni-plated brass
TSSx TSOSx
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
n [mm]
d [mm]
wires
Regular Design
DESIGN WITH TERMINAL BLOCK TYPE "M" (TS(O)SM)
50...1500
6
50...3000
8, 10
50...1500
6
50...3000
8, 10
1(2) x J 1(2) x L
T4
0...800 °C
1(2) x K
T3 T16 T6*
0...850 °C 0...1100 °C 0...1150 °C
1(2) x E
T3 T13
0...850 °C 0...1000 °C
50...1500
6
50...3000
8, 10
1(2) x S 1(2) x R
T16 T6*
0...1100 °C 0...1150 °C
50...1500
6
50...3000
8, 10
2 (2x2) 2 (2x2) 2 (2x2) 2 (2x2)
MI Design 1xJ
0...800 °C
50...50000
3, 4.5, 6, 8
T8
0...400 °C
50...50000
3, 4.5, 6, 8
0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C
50...50000
3, 4.5, 6, 8
2
2xK 2 x N, 2 x E
T3 T16 T6* T6*
50...50000
3, 4.5, 6, 8
2x2
2xS 2xR
T16 T6*
0...1100 °C 0...1150 °C
50...10000
3, 4.5, 6
2x2
1xT 2xT 1xK 1 x N, 1 x E
DESIGN WITH TERMINAL BLOCK TYPE "B" (TS(O)SB)
2
T4
2xJ
2x2 2 2x2
Suitable protection heads: (see Appendix - Protection Heads) - TS(O)SM: heads with 20 mm mounting distance - TS(O)SB: heads with 33 mm mounting distance Fixing to protection head: direct (default) or springing ('OS' option) Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Sheath material: 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362 (M15)
Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)
* Please contact COMECO! ** No transmitter mounted!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
MI sheath material: 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4876(M7), 2.4816(M8), Nicrobell® (M10)
temperature probes
Ordering code
TS (B, M) - (MI -) G1G2.G3.G4.G6.G10.G11.G14 - #1
Code Feature or option
Code values
Base model variant
S - standard (w/ terminal block), OS - prepared for in-head transmitter (w/o terminal block)
G1
Number of thermocouples
1 or 2
G2
Thermocouple
G3
Temperature range
G4
Diameter 'd' [mm]
G6
Insert length 'n' [mm] (1)
G10
Sheath material (wetted parts)
regular design
E - type "E", J - type "J", K - type "K", L - type "L", R - type "R", S - type "S"
MI design
E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T" T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (4), T13 - 0…1000 °C, T16 - 0…1100 °C
regular design
6, 8, 10
MI design
3, 4.5, 6, 8
regular design
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762, M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4404, M15 - 1.4362
MI design
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®
50…50000 (see table overleaf)
G11
Accuracy class
1 - '1' (4), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
#1
Options
X - none, OV - vibration proof (secured screws) (2,3), OS - spring-fixed terminal block, OP - electrochemically polished sheath surface (2)
(1)
This length does not coincide with the probe immersion length! Only for non-MI (regular) design! Requires 'OS' option! (4) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
(MI) RTD REPLACEABLE INSERT - PREPARED FOR IN-HEAD TRANSMITTER ** Sheath - stainless steel (see Appendix - Sheath materials) Terminal base - Al2O3. Terminals - Ni-plated brass
TSSx TSOSx
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
n [mm]
d [mm]
wires
Regular Design
DESIGN WITH TERMINAL BLOCK TYPE "M" (TS(O)SM) 1 x Pt (RB,RD,RF,RG)
2 x Pt (RB,RD,RF,RG) 3 x Pt * (RB,RD,RF,RG) 1 x Cu (RH, RK) 2 x Cu (RH, RK) 1 x PTC (RP, RQ)
T9 T1 T24 T11 T2 T4 T22 T9
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C -50...200 °C
T9
-50...200 °C
T12
-50...100 °C
50…200
4
2
50…500
5
2, 3*
50…1500
6
2, 3, 4*
50…3000
8
2, 3, 4
50…3000
6, 8, 10
2x2, 2x3*
50…3000
8, 10
3x2
50…1500
6
2, 3, 4*
8
2, 3, 4
50…3000 50…3000
2 x PTC (RP, RQ)
6
2x2*
8
2x2(3)*
50…1500
6
50…3000
8, 10
50…3000
8, 10
2, 3 2x2
MI Design 1 x Pt (RB,RD,RF,RG)
DESIGN WITH TERMINAL BLOCK TYPE "B" (TS(O)SB) 2 x Pt (RB,RD,RF,RG)
T9 T1 T24 T11 T2 T4 T22
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C
50...50000
50...50000
3*
2, 3*
4.5
2, 3*
6
2, 3, 4*
8
2, 3, 4
6, 8
2x2, 2x3*
Suitable protection heads: (see Appendix - Protection Heads) - TS(O)SM: heads with 20 mm mounting distance - TS(O)SB: heads with 33 mm mounting distance Fixing to protection head: direct (default) or springing ('OS' option) Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes) Sheath material: 1.4301(M1), 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362 (M15)
Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance)
* Please contact COMECO! ** No transmitter mounted!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Wire material: Cu, Ni, or Ag
temperature probes
Ordering code
TS (B, M) - (MI -) G1G2.G3.G4.G6.G10.G11.G12.G13.G14 - #1
Code Feature or option
Code values
Base model variant
S - standard (w/ terminal block), OS - prepared for in-head transmitter (w/o terminal block)
G1
Number of RTD sensors
1, 2, or 3 (7)
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP - PTC 1k, RQ - PTC 2k
G3
Temperature range
T1 - -50…400 °C, T2 - -200…600 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C, T22 - -200…200 °C, T24 - -50…500 °C
G4
Diameter 'd' [mm]
G6
Insert length 'n' [mm]
regular design
4, 5, 6, 8, 10
MI design
3 (7), 4.5, 6, 8
(1)
50…50000 (see table overleaf) regular design
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404, M15 - 1.4362
G10
Sheath material (wetted parts)
G11
Accuracy class
X - none (2), A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (7)
(3)
MI design
M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
CU - copper (4), NI - nickel, AG - silver (5)
G13
Wire material
G14
Tip shape
X - standard closed, N - narrowed (5), P - pitted (5)
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled) (5,6), OS - spring-fixed terminal block, OP - electrochemically polished sheath surface (5)
(1)
This length does not coincide with the probe immersion length! For non-Pt sensors Only for Pt sensors! (4) Not applicable to non-MI (regular) RTDs for above 500 °C! (5) Only for non-MI (regular) design! (6) Requires 'OS' option! (7) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
(MI) T/C REPLACEABLE INSERT - PREPARED FOR IN-HEAD TRANSMITTER ** Sheath - stainless steel (see Appendix - Sheath materials) Terminal base - Al2O3. Terminals - Ni-plated brass
TSSx TSOSx
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
n [mm]
d [mm]
wires
Regular Design
DESIGN WITH TERMINAL BLOCK TYPE "M" (TS(O)SM)
50...1500
6
50...3000
8, 10
50...1500
6
50...3000
8, 10
1(2) x J 1(2) x L
T4
0...800 °C
1(2) x K
T3 T16 T6*
0...850 °C 0...1100 °C 0...1150 °C
1(2) x E
T3 T13
0...850 °C 0...1000 °C
50...1500
6
50...3000
8, 10
1(2) x S 1(2) x R
T16 T6*
0...1100 °C 0...1150 °C
50...1500
6
50...3000
8, 10
2 (2x2) 2 (2x2) 2 (2x2) 2 (2x2)
MI Design 1xJ
0...800 °C
50...50000
3, 4.5, 6, 8
T8
0...400 °C
50...50000
3, 4.5, 6, 8
0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C
50...50000
3, 4.5, 6, 8
2
2xK 2 x N, 2 x E
T3 T16 T6* T6*
50...50000
3, 4.5, 6, 8
2x2
2xS 2xR
T16 T6*
0...1100 °C 0...1150 °C
50...10000
3, 4.5, 6
2x2
1xT 2xT 1xK 1 x N, 1 x E
DESIGN WITH TERMINAL BLOCK TYPE "B" (TS(O)SB)
2
T4
2xJ
2x2 2 2x2
Suitable protection heads: (see Appendix - Protection Heads) - TS(O)SM: heads with 20 mm mounting distance - TS(O)SB: heads with 33 mm mounting distance Fixing to protection head: direct (default) or springing ('OS' option) Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Sheath material: 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362 (M15)
Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)
* Please contact COMECO! ** No transmitter mounted!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
MI sheath material: 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4876(M7), 2.4816(M8), Nicrobell® (M10)
temperature probes
Ordering code
TS (B, M) - (MI -) G1G2.G3.G4.G6.G10.G11.G14 - #1
Code Feature or option
Code values
Base model variant
S - standard (w/ terminal block), OS - prepared for in-head transmitter (w/o terminal block)
G1
Number of thermocouples
1 or 2
G2
Thermocouple
G3
Temperature range
G4
Diameter 'd' [mm]
G6
Insert length 'n' [mm] (1)
G10
Sheath material (wetted parts)
regular design
E - type "E", J - type "J", K - type "K", L - type "L", R - type "R", S - type "S"
MI design
E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T" T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (4), T13 - 0…1000 °C, T16 - 0…1100 °C
regular design
6, 8, 10
MI design
3, 4.5, 6, 8
regular design
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762, M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4404, M15 - 1.4362
MI design
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®
50…50000 (see table overleaf)
G11
Accuracy class
1 - '1' (4), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
#1
Options
X - none, OV - vibration proof (secured screws) (2,3), OS - spring-fixed terminal block, OP - electrochemically polished sheath surface (2)
(1)
This length does not coincide with the probe immersion length! Only for non-MI (regular) design! Requires 'OS' option! (4) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes (MI) RTD PROBE WITH PROTECTION HEAD
TSCx
- FOR IN-HEAD TRANSMITTER ** TSOCx Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum, stainless steel, iron, or plastic (see Appendix - Protection heads)
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
n [mm]
d [mm]
wires
Regular Design
DESIGN WITHOUT EXTENSION (TS(O)C)
1 x Pt (RB,RD,RF,RG)
2(3) x Pt (RB,RD,RF,RG)
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C
1 x Cu (RH, RK)
T9
-50...200 °C
2 x Cu (RH, RK)
T9
-50...200 °C
T12
-50...100 °C
1 x PTC (RP, RQ)
EXTENDED DESIGN WITH WELDED CONNECTION (TS(O)C1)
T9 T1 T24 T11 T2 T4 T22
2 x Pt (RB,RD,RF,RG)
T9 T1 T24 T11 T2 T4 T22
50…1500
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C
2, 3* 2, 3, 4*
50…3000 8, 10, 12, 14, 16, 20
2, 3, 4
6*, 8, 10
2x2(3)*
12, 14, 16, 20
2x2(3), 3x2
50…3000 50…1500
6
2, 3, 4*
50…3000 8, 10, 12, 14, 16, 20 50…3000
50…1500 50…3000 50…3000 MI Design
2 x PTC (RP, RQ)
1 x Pt (RB,RD,RF,RG)
4 5 6
50…500
8, 10 12, 14, 16, 20 6 8, 10, 12, 14 8, 10, 12, 14
2x2 2x2(3)*
3*
2, 3*
50...50000
50...50000
2, 3 2x2
4.5
2, 3*
6
2, 3, 4*
8
2, 3, 4
6, 8
2x2, 2x3*
Protection head: B, MA, MB, G, N, Cx, Dx, Ex (see Appendix - Protection Heads)
EXTENDED DESIGN WITH MOVABLE CONNECTION (TS(O)C2)
Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Thermal isolation between nipple and metal head: (for TS(O)C only) Protection head MA, MB B other
Maximum temperature 200 °C 400 °C
Insulation material POM Teflon®
Extension length: m = 0…1500 mm Extension diameter: (for TS(O)C1 and TS(O)C2 only, [mm]) Probe diameter 'd' Ext. length 'm' up to 50 mm 50...150 mm 150...500 mm 500+ mm
3, 4 mm
4.5...6 mm
8 mm
10 mm
10+ mm
8 8 10 14
d 8 10 14
d d 10 14
d d d 14
d d d d
Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes) Process pressure:
DESIGN WITH GLAND-TYPE CONNECTION (TS(O)C4)
Probe design Max. pressure *
TS(O)C, TS(O)C1 25 bar
TS(O)C2 16 bar
TS(O)C4 6 bar
TS(O)C3 0 bar
Sheath material: 1.4301(M1), 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362(M15) Wire material: Cu, Ni, or Ag Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) * Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
DESIGN WITH ADJUSTABLE CONNECTION (TS(O)C3)
Length 'n' up to 50 mm up to 100 mm up to 150 mm
temperature probes
Ordering code
TS (1,2,3,4) - (MI -) G0.G1G2.G3.G4.G6.G7.G9'9".G10.G11.G12.G13.G14 - #1.#2
Code Feature or option
Code values
Base model variant
C - standard (w/ terminal block), OC - prepared for in-head transmitter (w/o terminal block)
G0
Protection head
B - type "B", CC - type "CC", CS - type "CS", D - type "D", DH - type "DH", DHW - type "DHW", DW - type "DW", E - type "E", EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", ES - type "ES", G - type "G", MA - type "MA", MB - type "MB", N - type "N"
G1
Number of RTD sensors
1, 2, or 3 (11)
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP - PTC 1k, RQ - PTC 2k
G3
Temperature range
T1 - -50…400 °C, T2 - -200…600 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C, T22 - -200…200 °C, T24 - -50…500 °C
G4
Diameter 'd' [mm]
regular design
4, 5, 6, 8, 10, 12, 14, 16, 20
MI design
3 (11), 4.5, 6, 8
(1)
G6
Probe length 'n' [mm]
G7
Probe length 'm' [mm] (2)
0…1500
50…50000 (see table overleaf)
G9'
Mounting connection
X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9"
Compression fitting ferrule (4)
BR - brass, GR - graphite, SS - stainless steel, TF - Teflon®
regular design
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404), M15 - 1.4362 (11)
MI design
M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404)
G10
Sheath material (wetted parts)
G11
Accuracy class
X - none (5), A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (11)
(6)
CU - copper (7), NI - nickel, AG - silver (8)
G13
Wire material
G14
Tip shape
X - standard closed, N - narrowed (8), P - pitted (8)
#1
Options
X - none, OV - vibration proof (spring terminals, MgO or Silicone filled, secured screws) (8), OT - thermal isolation (3), OP - electrochemically polished sheath surface (8)
#2
Incorporated devices
X - none, T - in-head transmitter (9), A - local indicator (10)
(1)
'n+m' for TS(O)C3 and TS(O)C4! Only for TS(O)C1 and TS(O)C2! Only for TS(O)C! (4) Only for TS(O)C4! (5) For non-Pt sensors (6) Only for Pt sensors! (7) Not applicable to non-MI (regular) RTDs for above 500 °C! (8) Only for non-MI (regular) design! (9) Only for variant 'OC'! See transmitter datasheets and order separately! (10) With windowed head only! See indicator datasheets and order separately! (11) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes (MI) T/C PROBE WITH PROTECTION HEAD
TSCx
- FOR IN-HEAD TRANSMITTER ** TSOCx Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum, stainless steel, iron, or plastic (see Appendix - Protection heads)
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
n [mm]
d [mm]
wires
50...1500 50...3000
6 8, 10, 12, 14, 16, 20, 22
2 (2x2)
50...1500
6
50...3000
8, 10, 12, 14, 16, 20, 22
Regular Design
DESIGN WITHOUT EXTENSION (TS(O)C)
1(2) x J 1(2) x L
T4
0...800 °C
1(2) x K
T3 T16 T6*
0...850 °C 0...1100 °C 0...1150 °C
1(2) x E
T3 T13
0...850 °C 0...1000 °C
50...1500
6
50...3000
8, 10, 12, 14, 16, 20, 22
1(2) x S 1(2) x R
T16 T6*
0...1100 °C 0...1150 °C
50...1500
6
50...3000
8, 10, 12, 14, 16, 20, 22
2 (2x2) 2 (2x2) 2 (2x2)
MI Design
EXTENDED DESIGN WITH WELDED CONNECTION (TS(O)C1)
1xJ 2xJ 1xT 2xT
2 2x2 2 2x2
T4
0...800 °C
50...50000
3, 4.5, 6, 8, 10*
T8
0...400 °C
50...50000
3, 4.5, 6, 8, 10*
0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C
50...50000
3, 4.5, 6, 8, 10*
2
2xK 2 x N, 2 x E
T3 T16 T6* T6*
50...50000
3, 4.5, 6, 8, 10*
2x2
2xS 2xR
T16 T6*
0...1100 °C 0...1150 °C
50...10000
3, 4.5, 6
2x2
1xK 1 x N, 1 x E
Protection head: B, MA, MB, G, N, Cx, Dx, Ex (see Appendix - Protection Heads)
EXTENDED DESIGN WITH MOVABLE CONNECTION (TS(O)C2)
Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Thermal isolation between nipple and metal head: (for TS(O)C only) Protection head MA, MB B other
Length 'n' up to 50 mm up to 100 mm up to 150 mm
Maximum temperature 200 °C 400 °C
Insulation material POM Teflon®
Extension length: m = 0…1500 mm Extension diameter: (for TS(O)C1 and TS(O)C2 only, [mm]) Probe diameter 'd' Ext. length 'm' up to 50 mm 50...150 mm 150...500 mm 500+ mm
3 mm
4.5, 6 mm
8 mm
10 mm
10+ mm
6 8 10 14
d 8 10 14
d d 10 14
d d d 14
d d d d
Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Process pressure: Probe design Max. pressure *
DESIGN WITH GLAND-TYPE CONNECTION (TS(O)C4)
TS(O)C, TS(O)C1 25 bar
TS(O)C2 16 bar
TS(O)C4 6 bar
TS(O)C3 0 bar
Sheath material: 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362 (M15) MI sheath material: 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4876(M7), 2.4816(M8), Nicrobell® (M10) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) * Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
DESIGN WITH ADJUSTABLE CONNECTION (TS(O)C3)
temperature probes
Ordering code
TS (1,2,3,4) - (MI -) G0.G1G2.G3.G4.G6.G7.G9'9".G10.G11.G14 - #1.#2
Code Feature or option
Code values
Base model variant
C - standard (w/ terminal block), OC - prepared for in-head transmitter (w/o terminal block)
G0
Protection head
B - type "B", CC - type "CC", CS - type "CS", D - type "D", DH - type "DH", DHW - type "DHW", DW - type "DW", E - type "E", EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", ES - type "ES", G - type "G", MA - type "MA", MB - type "MB", N - type "N"
G1
Number of thermocouples
1 or 2
G2
Thermocouple
G3
Temperature range
G4
Diameter 'd' [mm]
G6
Probe length 'n' [mm] (1)
50…50000 (see table overleaf)
G7
Probe length 'm' [mm] (2)
0…1500
G9'
Mounting connection
X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9"
Compression fitting ferrule (4)
BR - brass, GR - graphite, SS - stainless steel, TF - Teflon®
G10
Sheath material (wetted parts)
regular design
E - type "E", J - type "J", K - type "K", L - type "L", R - type "R", S - type "S"
MI design
E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T" T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (8), T13 - 0…1000 °C, T16 - 0…1100 °C
regular design MI design
6, 8, 10, 12, 14, 16, 20, 22 3, 4.5, 6, 8, 10
regular design
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762, M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4401 (1.4404), M15 - 1.4362
MI design
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4401 (1.4404), M10 - Nicrobell®
G11
Accuracy class
1 - '1' (8), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
#1
Options
X - none, OV - vibration proof (spring terminals (8), secured screws), OT - thermal isolation (3), OP - electrochemically polished sheath surface (5)
#2
Incorporated devices
X - none, T - in-head transmitter (6), A - local indicator (7)
(1)
'n+m' for TS(O)C3 and TS(O)C4! Only for TS(O)C1 and TS(O)C2! Only for TS(O)C! (4) Only for TS(O)C4! (5) Only for non-MI (regular) design! (6) Only for variant 'OC'! See transmitter datasheets and order separately! (7) With windowed head only! See indicator datasheets and order separately! (8) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes RTD PROBE WITH PROTECTION HEAD AND (MI) INSERT
TSCSx
- FOR IN-HEAD TRANSMITTER ** TSOCSx Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum, stainless steel, or plastic (see Appendix - Protection heads)
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
d [mm]
d insert [mm]
wires
Regular Insert Design
DESIGN WITHOUT EXTENSION (TS(O)CS)
1 x Pt (RB,RD,RF,RG)
2 x Pt (RB,RD,RF,RG) 1 x Cu (RH, RK) 2 x Cu (RH, RK)
EXTENDED DESIGN WITH WELDED CONNECTION (TS(O)CS1) 1 x Pt (RB,RD,RF,RG)
2 x Pt (RB,RD,RF,RG)
T9 T1 T24 T11 T2 T4 T22 T9 T9
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C -50...200 °C -50...200 °C
8
4, 5
2, 3*
9, 10, 12, 14, 16, 20
6
2, 3, 4*
12, 14, 16, 20
8
2, 3, 4
9, 10, 12, 14, 16, 20
6
2x2*
12, 14, 16, 20
8
2x2(3)*
9, 10, 12, 14, 16, 20
6
2, 3, 4*
12, 14, 16, 20
8
2, 3, 4
9, 10, 12, 14, 16, 20
6
2x2*
12, 14, 16, 20
8
2x2(3)*
3*
2, 3*
4.5
2, 3*
6
2, 3, 4*
MI Insert Design 6, 8, 9, 10, 12, 14, T9 -50...200 °C 16, 20 T1 -50...400 °C 8, 9, 10, 12, 14, T24 -50...500 °C 16, 20 T11 -50...600 °C 9, 10, 12, 14, 16, 20 T2 -200...600 °C 12, 14, 16, 20 0...800 °C 9, 10, 12, 14, 16, 20 T4 T22 -200...200 °C 12, 14, 16, 20
8
2, 3, 4
6
2x2, 2x3*
8
2x2, 2x3*
Protection head: B, MA, MB, G, N, Cx, Dx, Ex (see Appendix - Protection Heads)
EXTENDED DESIGN WITH MOVABLE CONNECTION (TS(O)CS2)
Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Thermal isolation between nipple and metal head: (for TS(O)CS only) Protection head
DESIGN WITH ADJUSTABLE CONNECTION (TS(O)CS3)
Length 'n'
Maximum temperature
Insulation material
MA, MB B
up to 50 mm up to 100 mm
200 °C
POM
other
up to 150 mm
400 °C
Teflon®
Extension length: m = 0…1500 mm Probe diameter 'd' Ext. length 'm'
6 mm
8 mm
9, 10 mm
10+ mm
up to 50 mm
d
d
d
d
50...150 mm
8
d
d
d
150...500 mm
10
10
d
d
500+ mm
14
14
14
d
Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes)
DESIGN WITH GLAND-TYPE CONNECTION (TS(O)CS4)
Process pressure: Probe design Max. pressure *
TS(O)CS, TS(O)CS1 TS(O)CS2 25 bar
16 bar
TS(O)CS4
TS(O)CS3
6 bar
0 bar
Sheath material: 1.4301(M1), 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362(M15) Wire material: Cu, Ni, or Ag Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) * Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Extension diameter: (for TS(O)CS1 and TS(O)CS2 only, [mm])
temperature probes
Ordering code
TS (1,2,3,4) - (MI -) G0.G1G2.G3.G4.G6.G7.G9'9".G10.G11.G12.G13.G14 - #1.#2
Code Feature or option
Code values
Base model variant
CS - standard (w/ terminal block), OCS - prepared for in-head transmitter (w/o terminal block)
Protection head
B - type "B", CC - type "CC", CS - type "CS", D - type "D", DH - type "DH", DHW - type "DHW", DW - type "DW", E - type "E", EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", ES - type "ES", G - type "G", MA - type "MA", MB - type "MB", N - type "N"
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100
G3
Temperature range
T1 - -50…400 °C, T2 - -200…600 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C, T22 - -200…200 °C, T24 - -50…500 °C
G4
Diameter 'd' / 'd insert' [mm]
G6
Probe length 'n' [mm] (1)
G0
G7
Probe length 'm' [mm]
regular insert
8/4, 8/5, 9/6, 10/6, 12/6, 14/6, 12/8, 14/8, 16/6, 16/8, 20/6, 20/8
MI insert
6/3 (12), 8/4.5, 9/6, 10/6, 12/6, 14/6, 16/6, 16/8, 20/6, 20/8 50…3000
(2)
0…1500
G9'
Mounting connection
X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9"
Compression fitting ferrule (4)
TF - Teflon®, BR - brass, SS - stainless steel
G10
Sheath material (wetted parts and insert)
G11
Accuracy class
X - none (5), A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (12)
G13
Wire material (6)
CU - copper (7), NI - nickel, AG - silver (8)
G14
Tip shape
X - standard closed, N - narrowed (12), P - pitted
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled insert, secured screws) (8,9), OS - spring-loaded insert, OT - thermal isolation (3), OP - electrochemically polished wetted parts
#2
Incorporated devices
X - none, T - in-head transmitter (10), A - local indicator (11)
regular insert
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404), M15 - 1.4362 (12)
MI insert
M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404)
(1)
'n+m' for TS(O)CS3 and TS(O)CS4! Only for TS(O)CS1 and TS(O)CS2! Only for TS(O)CS! (4) Only for TS(O)CS4! (5) For non-Pt sensors (6) Only for Pt sensors! (7) Not applicable to non-MI (regular) RTD inserts for above 500 °C! (8) Only for non-MI (regular) inserts! (9) Requires 'OS' option! (10) Only for variant 'OCS'! See transmitter datasheets and order separately! (11) With windowed head only! See indicator datasheets and order separately! (12) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes T/C PROBE WITH PROTECTION HEAD AND (MI) INSERT
TSCSx
- FOR IN-HEAD TRANSMITTER ** TSOCSx Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum, stainless steel, or plastic (see Appendix - Protection heads)
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
d [mm]
d insert [mm]
wires
Regular Insert Design
DESIGN WITHOUT EXTENSION (TS(O)CS)
10, 12, 14, 16, 20
6, 8, 10
2
12, 14, 16, 20
8, 10
2x2
0...850 °C 0...1100 °C 0...1150 °C
10, 12, 14, 16, 20
6, 8, 10
2
12, 14, 16, 20
8, 10
2x2
0...850 °C 0...1000 °C
10, 12, 14, 16, 20
6, 8, 10
2
2xE
T3 T13
12, 14, 16, 20
8, 10
2x2
1xS 1xR
T16 T6*
0...1100 °C 0...1150 °C
10, 12, 14, 16, 20
6, 8, 10
2
2xS 2xR
T16 T6*
0...1100 °C 0...1150 °C
12, 14, 16, 20
8, 10
2x2
1 x J; 1 x L 2 x J; 2 x L 1xK 2xK 1xE
EXTENDED DESIGN WITH WELDED CONNECTION (TS(O)CS1)
T4
0...800 °C
T3 T16 T6*
MI Insert Design 1xJ 2xJ 1xK 1 x N, 1 x E 2xK 2 x N, 2 x E
T4
0...800 °C
6, 8, 10, 12, 14, 16, 20
3, 4.5, 6, 8
T3 T16 T6* T6*
0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C
8, 10, 12, 14, 16, 20
4.5, 6, 8
2 2x2 2 2x2
Protection head: B, MA, MB, G, N, Cx, Dx, Ex (see Appendix - Protection Heads)
EXTENDED DESIGN WITH MOVABLE CONNECTION (TS(O)CS2)
Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Thermal isolation between nipple and metal head: (for TS(O)CS only) Protection head
DESIGN WITH ADJUSTABLE CONNECTION (TS(O)CS3)
Length 'n' up to 50 mm
Maximum temperature
B
up to 100 mm
200 °C
POM
other
up to 150 mm
400 °C
Teflon®
MA, MB
Insulation material
Process length: n = 50…3000 mm Extension length: m = 0…1500 mm Probe diameter 'd' Ext. length 'm'
DESIGN WITH GLAND-TYPE CONNECTION (TS(O)CS4)
6 mm
8 mm
10 mm
10+ mm d
up to 50 mm
d
d
d
50...150 mm
8
d
d
d
150...500 mm
10
10
d
d
500+ mm
14
14
14
d
Insert tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Process pressure: Probe design Max. pressure *
TS(O)CS, TS(O)CS1 TS(O)CS2 25 bar
16 bar
TS(O)CS4
TS(O)CS3
6 bar
0 bar
Sheath material: 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762/1.4749(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362(M15) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) * Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Extension diameter: (for TS(O)CS1 and TS(O)CS2 only, [mm])
temperature probes
Ordering code
TS (1,2,3,4) - (MI -) G0.G1G2.G3.G4.G6.G7.G9'9".G10.G11.G14 - #1.#2
Code Feature or option
Code values
Base model variant
CS - standard (w/ terminal block), OCS - prepared for in-head transmitter (w/o terminal block)
G0
Protection head
B - type "B", CC - type "CC", CS - type "CS", D - type "D", DH - type "DH", DHW - type "DHW", DW - type "DW", E - type "E", EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", ES - type "ES", G - type "G", MA - type "MA", MB - type "MB", N - type "N"
G1
Number of thermocouples
1 or 2 regular insert
E - type "E", J - type "J", K - type "K", L - type "L", R - type "R", S - type "S"
MI insert
E - type "E", J - type "J", K - type "K", N - type "N"
G2
Thermocouple
G3
Temperature range
G4
Diameter 'd' / 'd insert' [mm]
G6
Probe length 'n' [mm] (1)
50…3000
G7
Probe length 'm' [mm] (2)
0…1500
G9'
Mounting connection
X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9"
Compression fitting ferrule (4)
G10
Sheath material (wetted parts and insert)
T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (8), T13 - 0…1000 °C, T16 - 0…1100 °C regular insert
10/6, 10/8, 12/6, 12/8, 14/6, 14/8, 14/10, 16/10, 20/10
MI insert
6/3, 8/4.5, 10/6, 12/6, 14/6, 16/6, 20/6, 20/8
TF - Teflon®, BR - brass, SS - stainless steel
regular insert
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4401 (1.4404), M15 - 1.4362
MI insert
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M8 - 2.4816, M9 - 1.4401 (1.4404)
G11
Accuracy class
1 - '1' (8), 2 - '2'
G14
Insert tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
#1
Options
X - none, OV - vibration proof (secured screws) (5), OS - spring-loaded insert, OT - thermal isolation (3), OP - electrochemically polished wetted parts
#2
Incorporated devices
X - none, T - in-head transmitter (6), A - local indicator (7)
(1)
'n+m' for TS(O)CS3 and TS(O)CS4! Only for TS(O)CS1 and TS(O)CS2! Only for TS(O)CS! (4) Only for TS(O)CS4! (5) Requires 'OS' option! (6) Only for variant 'OCS'! See transmitter datasheets and order separately! (7) With windowed head only! See indicator datasheets and order separately! (8) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes ANGLED RTD PROBE WITH PROTECTION HEAD
Lx (TSLx)
(FOR IN-HEAD TRANSMITTER)** OLx (TSOLx) Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum, stainless steel, or plastic (see Appendix - Protection heads) DESIGN WITHOUT FLANGE (L)
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
-50...200 °C -50...400 °C -50...600 °C -200...600 °C -0...800 °C
d [mm]
wires
2(3) x Pt (RB,RD,RF,RG)
T9 T1 T11 T2 T4
1 x Cu (RH, RK)
T9
-50...200 °C
10, 12, 14, 16, 20, 22
2, 3, 4*
2 x Cu (RH, RK)
T9
-50...200 °C
12, 14, 16, 20, 22
2x2(3)*
1 x Pt (RB,RD,RF,RG)
10, 12, 14, 16, 20, 22
2, 3, 4*
12, 14, 16, 20, 22
2x2(3)* 3x2*
Protection head: B, MA, MB, G, N, Dx, Ex, EX (see Appendix - Protection heads) Process connection: - welded flange - adjustable flange - no mounting appliances Insertion length: n = 200…1500 mm
DESIGN WITH WELDED FLANGE (L1)
Extension length: m = 100…1000 mm Holding tube: - m1 = 100…1000 mm - OD 20(22) mm - tube/elbow material 1.4301 or 1.4541 Tip shape: standard, narrowed, pitted (see Appendix - Tip shapes) Process pressure: Probe design Max. pressure *
L, L1
L3
25 bar
0 bar
Sheath material: 1.4301(M1), 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362 (M15) Wire material: Cu, Ni, or Ag
DESIGN WITH ADJUSTABLE FLANGE (L3)
* Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance)
temperature probes
Ordering code
TS (1,3) - G0.G1G2.G3.G4.G6.G7'.G7".G9.G10.G11.G12.G13.G14 - #1.#2
Code Feature or option
Code values
Base model variant
L - standard (w/ terminal block), OL - prepared for in-head transmitter (w/o terminal block)
G0
Protection head
B - type "B", MA - type "MA", MB - type "MB", G - IP65, type "G", N - type "N", D - type "D", DW - windowed, type "DW", DH - w/ high cap, type "DH", DHW - windowed, type "DHW", E - IP65, type "E", ES - stainless-steel, type "ES", EG - IP68 ATEX-approved, type "EG", EGS - IP66 ATEX-approved, type "EGS", EGW - windowed ATEX-approved, type "EGW", EX - explosion-proof instrument housing (specify!)
G1
Number of RTD sensors
1, 2, or 3 (6)
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100
G3
Temperature range
T1 - -50…400 °C, T2 - -200…600 °C (Ni or Ag wires only!), T4 - 0…800 °C (Ag wires only!), T9 - -50…200 °C, T11 - -50…600 °C (Ni or Ag wires only!)
G4
Diameter 'd' [mm]
10, 12, 14, 16, 20, 22
G6
Probe length 'n' [mm] (1)
200…1500
G7'
Probe length 'm' [mm] (2)
100…1000
G7"
Probe length 'm1' [mm]
100…1000
G9
Mounting connection
X - no mounting appliances, F - flange (specify!), Z - other connection (specify!)
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404, M15 - 1.4362
G11
Accuracy class (3)
A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (6)
(3)
G13
Wire material
CU - copper, NI - nickel, AG - silver
G14
Tip shape
X - standard closed, N - narrowed, P - pitted (4)
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled, secured screws), OP - electrochemically polished sheath surface
#2
Local indicator
X - none, A - local indicator mounted (5)
(1)
'n+m' for TS(O)L3! Only for TS(O)L1! Only for Pt sensors! (4) Only for non-explosion-proof RTDs! (5) With windowed head only! See indicator datasheets and order separately! (6) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes ANGLED T/C PROBE WITH PROTECTION HEAD
Lx (TSLx)
(FOR IN-HEAD TRANSMITTER)** OLx (TSOLx) Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum, stainless steel, or plastic (see Appendix - Protection heads)
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
d [mm]
wires
Regular Thermocouple Design
DESIGN WITHOUT FLANGE (L)
T4
0...800 °C
10, 12, 14, 16, 20, 22
T3 T16 T6*
0...850 °C 0...1100 °C 0...1150 °C
10, 12, 14, 16, 20, 22
2xE
T3 T13
0...850 °C 0...1000 °C
10, 12, 14, 16, 20, 22
1xS 1xR
T16 T6*
0...1100 °C 0...1150 °C
10, 12, 14, 16, 20, 22
2
2xS 2xR
T16 T6*
0...1100 °C 0...1150 °C
10, 12, 14, 16, 20, 22
2x2
1xJ
T4
0...800 °C
10
2
1xK 1 x N; 1 x E
T3 T16
0...850 °C 0...1100 °C
10
2
2xK
T3 T16
0...850 °C 0...1100 °C
10
2x2
1 x J; 1 x L 2 x J; 2 x L 1xK 2xK 1xE
2 2x2 2 2x2 2 2x2
MI Thermocouple Design
DESIGN WITH WELDED FLANGE (L1)
Protection head: B, MA, MB, G, N, Dx, Ex, EX (see Appendix - Protection heads) Process connection: - welded flange - adjustable flange - no mounting appliances Insertion length: n = 200…1500 mm Extension length: m = 100…1000 mm Holding tube: - m1 = 100…1000 mm - OD 20(22) mm - material 1.4301 or 1.4541 Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip shapes) Process pressure: Probe design Max. pressure *
L, L1
L3
25 bar
0 bar
Sheath material: 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362 (M15) MI sheath material: 1.4541(M2), 1.4571(M3), 1.4876(M7), 2.4816(M8) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)
* Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
DESIGN WITH ADJUSTABLE FLANGE (L3)
temperature probes
Ordering code
TS (1,3) - G0.G1G2.G3.G4.G6.G7'.G7".G9.G10.G11.G14 - #1.#2
Code Feature or option
Code values
Base model variant
L - standard (w/ terminal block), OL - prepared for in-head transmitter (w/o terminal block)
G0
Protection head
B - type "B", MA - type "MA", MB - type "MB", G - IP65, type "G", N - type "N", D - type "D", DW - windowed, type "DW", DH - w/ high cap, type "DH", DHW - windowed, type "DHW", E - IP65, type "E", ES - stainless-steel, type "ES", EG - IP68 ATEX-approved, type "EG", EGS - IP66 ATEX-approved, type "EGS", EGW - windowed ATEX-approved, type "EGW", EX - explosion-proof instrument housing (specify!)
G1
Number of thermocouples
1 or 2
G2
Thermocouple
J - type "J", K - type "K", N - type "N", E - type "E", L - type "L", S - type "S", R - type "R"
G3
Temperature range
T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (5), T13 - 0…1000 °C, T16 - 0…1100 °C
G4
Diameter 'd' [mm]
G6
Probe length 'n' [mm] (1)
200…1500
G7'
Probe length 'm' [mm] (2)
100…1000
G7"
Probe length 'm1' [mm]
100…1000
G9
Mounting connection
X - no mounting appliances, F - flange (specify!), Z - other connection (specify!)
G10
Sheath material
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762, M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4404, M15 - 1.4362
G11
Accuracy class
1 - '1' (5), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction (3), O - open-tube design (3)
#1
Options
X - none, OV - vibration proof (spring-type terminals (5), secured screws), OP - electrochemically polished sheath surface
#2
Local indicator
X - none, A - local indicator mounted (4)
regular T/C MI T/C
regular T/C MI T/C
10, 12, 14, 16, 20, 22 10
M2 - 1.4541, M3 - 1.4571, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600)
(1)
'n+m' for TS(O)L3! Only for TS(O)L1! Only for non-explosion-proof thermocouples! (4) With windowed head only! See indicator datasheets and order separately! (5) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes RTD PROBE WITH PROTECTION HEAD AND OPEN REPLACEABLE INSERT FOR THERMOWELL OR PROTECTION TUBE
DSx (TSDSx)
(FOR IN-HEAD TRANSMITTER)** ODSx (TSODSx) Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum, stainless steel, or plastic (see Appendix - Protection heads) DESIGN WITHOUT EXTENSION (DS)
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
-50...200 °C -50...400 °C -50...600 °C -200...600 °C -0...800 °C
2 x Pt (RB,RD,RF,RG)
T9 T1 T11 T2 T4
1 x Cu (RH, RK)
T9
-50...200 °C
2 x Cu (RH, RK)
T9
-50...200 °C
1 x Pt (RB,RD,RF,RG)
D [mm]
d [mm]
wires
8, 10 10, 12 12, 14
5 6 8
2, 3* 2, 3, 4* 2, 3, 4
10, 12 12, 14 10, 12 12, 14 10, 12 12, 14
6 8 6 8 6 8
2x2* 2x2(3)* 2, 3, 4* 2, 3, 4 2x2* 2x2(3)*
Protection head: B, MA, MB, G, N, Dx, Ex, EX (see Appendix - Protection heads)
EXTENDED DESIGN WITH WELDED CONNECTION (DS1)
Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded flange Thermal isolation between nipple and metal head: (for TS(O)DS only) Protection head
EXTENDED DESIGN WITH MOVABLE CONNECTION (DS2)
Length 'n' up to 50 mm
Maximum temperature
B
up to 100 mm
200 °C
POM
other
up to 150 mm
400 °C
Teflon®
MA, MB
Insulation material
Insertion length (must fit thermowell / protection tube length 'L'!): n = 50…2000 mm Extension length: m = 50…1000 mm (w/o spring-loaded adapter) m = m1...1000 mm (w/ spring-loaded adapter) Tip shape: standard, narrowed, pitted (see Appendix - Tip shapes) Process pressure: - with metal thermowell up to 500 bar (see Accessories - Thermowells) - with ceramic protection tube (see Accessories - Protection tubes) *
DESIGN WITH SLIDING GLAND-TYPE CONNECTION (DS4)
Sheath material: 1.4301(M1) or 1.4541(M2)
Wire material: Cu, Ni, or Ag Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Spring-loaded adapter: (mounted between probe and protection head)
DESIGN WITH NIPPLE-UNION-NIPPLE CONNECTION (DS5)
m1
20...25
* Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
m1 = 60…100 mm
COMECO reserves the right of changing specifications without prior notice!
Insert sheath material: 1.4301(M1), 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362 (M15)
temperature probes
Ordering code
TS (1,2,4,5) - G0.G1G2.G3.G4.G6.G7.G9'9".G10.G11.G12.G13.G14 - #1.#2
Code Feature or option
Code values
Base model variant
DS - standard (w/ terminal block), ODS - prepared for in-head transmitter (w/o terminal block)
G0
Protection head
B - type "B", MA - type "MA", MB - type "MB", G - IP65, type "G", N - type "N", D - type "D", DW - windowed, type "DW", DH - w/ high cap, type "DH", DHW - windowed, type "DHW", E - IP65, type "E", ES - stainless-steel, type "ES", EG - IP68 ATEX-approved, type "EG", EGS - IP66 ATEX-approved, type "EGS", EGW - windowed ATEX-approved, type "EGW", EX - explosion-proof instrument housing (specify!)
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100
G3
Temperature range
T1 - -50…400 °C, T2 - -200…600 °C (Ni or Ag wires only!), T4 - 0…800 °C (Ag wires only!), T9 - -50…200 °C, T11 - -50…600 °C (Ni or Ag wires only!)
G4
Diameters 'D/d' [mm] (1)
8/5, 10/5, 10/6, 12/6, 14/6, 14/8, 20/6, 21/6, 20/8, 21/8
G6
Probe length 'n' [mm]
50…2000
G7
Probe length 'm' [mm] (2)
50…1000 (m1…1000 with 'OA' option)
G9'
Mounting connection
X - no mounting appliances, Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9"
Compression fitting ferrule (3)
TF - Teflon®, BR - brass, SS - stainless steel
G10
Insert sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404, M15 - 1.4362
(4)
G11
Accuracy class
G12
Number of wires
A - 'A', B - 'B', C - '2xB' 2, 3, 4 (10)
G13
Wire material (4)
CU - copper, NI - nickel, AG - silver
G14
Tip shape
X - standard closed, N - narrowed, P - pitted (5)
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled insert, secured screws) (6), OS - spring-loaded insert, OT - thermal isolation (7), OA - spring-loaded adapter (8), OP - electrochemically polished sheath surface
#2
Local indicator
X - none, A - local indicator mounted (9)
(1)
Only 'd' for TS(O)DS! Omit for TS(O)DS without 'OA' option! (3) Only for TS(O)DS4! (4) Only for Pt sensors! (5) Only for non-explosion-proof RTDs! (6) Requires 'OS' option! (7) Only for TS(O)DS! (8) Only for TS(O)DS, TS(O)DS1, and TS(O)DS5! Insert is not replaceable! (9) With windowed head only! See indicator datasheets and order separately! (10) Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes T/C PROBE WITH PROTECTION HEAD AND OPEN REPLACEABLE INSERT FOR THERMOWELL OR PROTECTION TUBE
DSx (TSDSx)
(FOR IN-HEAD TRANSMITTER)*** ODSx (TSODSx) Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum, stainless steel, or plastic (see Appendix - Protection heads)
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
D [mm]
d [mm]
wires
MI Thermocouple Insert Design
DESIGN WITHOUT EXTENSION (DS)
1xJ
2
T4
0...800 °C
8,10,12,14
3, 4.5, 6, 8
T3 T16 T6* T6*
0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C
8,10,12,14
3, 4.5, 6, 8
1 x S, 1 x R
T16 T6*
0...1100 °C 0...1150 °C
8,10,12,14
3, 4.5, 6
2
2 x S, 2 x R
T16 T6* T14** T15**
0...1100 °C 0...1150 °C 0...1600 °C 0...1700 °C
8,10,12,14
3, 4.5, 6
2x2
2xJ 1xK 1 x N, 1 x E 2xK 2 x N, 2 x E
EXTENDED DESIGN WITH WELDED CONNECTION (DS1)
2x2 2 2x2
Protection head: B, MA, MB, G, N, Dx, Ex, EX (see Appendix - Protection heads) Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded flange Thermal isolation between nipple and metal head: (for TS(O)DS only) Protection head
EXTENDED DESIGN WITH MOVABLE CONNECTION (DS2)
Length 'n'
MA, MB
up to 50 mm
Maximum temperature
B other
up to 100 mm up to 150 mm
200 °C 400 °C
Insulation material POM Teflon®
Insertion length (must fit thermowell / protection tube length 'L'!): n = 50…2000 mm Extension length: m = 50…1000 mm (w/o spring-loaded adapter) m = m1...1000 mm (w/ spring-loaded adapter) Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip shapes) Process pressure: - with metal thermowell up to 500 bar (see Accessories - Thermowells) - with ceramic protection tube (see Accessories - Protection tubes) * Sheath material: 1.4301(M1) or 1.4541(M2) MI-insert sheath material: 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4876(M7), 2.4816(M8) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)
DESIGN WITH NIPPLE-UNION-NIPPLE CONNECTION (DS5)
Spring-loaded adapter: (mounted between probe and protection head)
m1
20...25
* Please contact COMECO! ** With ceramic protection tubes only! *** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
m1 = 60…100 mm
COMECO reserves the right of changing specifications without prior notice!
DESIGN WITH SLIDING GLAND-TYPE CONNECTION (DS4)
temperature probes
Ordering code
TS (1,2,4,5) - G0.G1G2.G3.G4.G6.G7.G9'9".G10.G11.G14 - #1.#2
Code Feature or option
G0
Code values
Base model variant
DS - standard (w/ terminal block), ODS - prepared for in-head transmitter (w/o terminal block)
Protection head
B - type "B", MA - type "MA", MB - type "MB", G - IP65, type "G", N - type "N", D - type "D", DW - windowed, type "DW", DH - w/ high cap, type "DH", DHW - windowed, type "DHW", E - IP65, type "E", ES - stainless-steel, type "ES", EG - IP68 ATEX-approved, type "EG", EGS - IP66 ATEX-approved, type "EGS", EGW - windowed ATEX-approved, type "EGW", EX - explosion-proof instrument housing (specify!)
G1
Number of thermocouples
1 or 2
G2
Thermocouple
J - type "J", K - type "K", N - type "N", E - type "E", L - type "L", S - type "S", R - type "R"
G3
Temperature range
T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (9), T13 - 0…1000 °C, T14 - 0…1600 °C, T15 - 0…1700 °C, T16 - 0…1100 °C
G4
Diameters 'D/d' [mm] (1)
8/3, 10/3, 8/4.5, 10/4.5, 12/6, 14/6, 20/6 (2), 21/6, 20/8 (2), 21/8
G6
Probe length 'n' [mm]
50…2000
G7
Probe length 'm' [mm] (3)
50…1000 (m1…1000 with 'OA' option)
G9'
Mounting connection
X - no mounting appliances, Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9"
Compression fitting ferrule (4)
TF - Teflon®, BR - brass, SS - stainless steel
G10
Insert sheath material
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762, M5 - 1.4841, M6 - 1.4845, M8 - 2.4816, M9 - 1.4404
G11
Accuracy class
1 - '1' (9), 2 - '2'
G14
Insert tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
#1
Options
X - none, OV - vibration proof (secured screws) (5), OS - spring-loaded insert, OT - thermal isolation (6), OA - spring-loaded adapter (7), OP - electrochemically polished sheath surface
#2
Local indicator
X - none, A - local indicator mounted (8)
(1)
Only 'd' for TS(O)DS! Not available with G10='M6' Omit for TS(O)DS without 'OA' option! (4) Only for TS(O)DS4! (5) Requires 'OS' option! (6) Only for TS(O)DS! (7) Only for TS(O)DS, TS(O)DS1, and TS(O)DS5! Insert is not replaceable! (8) With windowed head only! See indicator datasheets and order separately! (9) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
(MI) T/C PROBE WITH PROTECTION HEAD AND CERAMIC PROTECTION TUBE
TSZx
- FOR IN-HEAD TRANSMITTER ** TSOZx Holding tube - stainless steel 1.4301 or 1.4404 Protection tube - ceramic (see Accessories - Protection tubes) Head - aluminum, stainless steel, iron, or plastic (see Appendix - Protection heads)
WIRE [mm] SENSITIVE TEMPERATURE TUBE / ELEMENT RANGE MATERIAL MI [mm]
DIMENSIONS d [mm]
D [mm]
Regular Design T13
STRAIGHT DESIGN (TS(O)Z)
T6
0...1000 °C 0...1200 °C
1.0
C1(2),C6
10
16
C1(2)
15
22
C6, C7
16, 19
22, 24
C5
17
24
C1(2)
24
32
C4, C7
22, 28
30, 36
C5
23
30
C6
25, 32
32, 40
C1(2)
10,15,24
16,22,32
C4
22
30
C5
17, 23
24, 30
1.5
1 x K; 1 x N 2 X K, 2 X N T6
T21
0...1200 °C
0...1300 °C
3.0
0.35
C6 10,16,19,25 16,22,24,32 1 x S; 1 x R 2 X S, 2 X R T5
ANGLED DESIGN (TS(O)ZL)
0...1500 °C
0.35, 0.5
T14
0...1600 °C
0.5
1 x B; 2 x B
T14
0...1600 °C
0.35
1 x B; 2 x B
T15
0...1700 °C
0.5
T16
0...1100 °C
C7*
16,22,28
22,30,36
C1(2)
10,15,24
16,22,32
C5
17, 23
24, 30
C6 10,16,19,25 16,22,24,32 C2
10,15,24
16,22,32
C6 10,16,19,25 16,22,24,32 C2
10,15,24
16,22,32
C6 10,16,19,25 16,22,24,32 C3
10,15,24
16,22,32
C6* 10,16,19,25 16,22,24,32
1 x K; 1 x N 2 X K, 2 X N
T16 0...1100 °C (Inconel 600) T6 0...1200 °C (Nicrobell®)
1 x S, 2 x S
n = 200…nmax nmax can be defined from the table below: n [mm] ≤ 400 ≤ 800 ≤ 1800
d≤ single L - 50 L - 70 L - 100
16 double L - 70 L - 100 L - 100
d ≤ 32 any L - 100 L - 100 L - 100
where 'L' is the length of the protection tube (see Accessories - Protection Tubes) Holding tube: - m1 = 100…1000 mm - OD 20(22) mm - tube/elbow material 1.4301 or 1.4541
T16 0...1100 °C (Inconel 600)
10
16
C1
15
22
C6, C7
16, 19
22, 24
C5
17, 23
24, 30
3, 4.5, 6, 8, 10
C1
24
32
C4, C7
22, 28
30, 36
C6
25, 32
32, 40
3, 4.5
C1, C6
10
16
C1
15
22
C6, C7
16, 19
22, 24
C5
17, 23
24, 30
3, 4.5, 6, 8
3, 4.5, 6
Protection head: B, MA, MB, G, N, Cx, Dx, Ex (see Appendix - Protection Heads) Process connection: - welded or adjustable flange - w/o mounting appliances Extension length: m = 100…1000 mm Extension tube material: 1.4301(M1), 1.4541(M2), 1.4404(M9), 1.4571(M3) MI sheath material: 2.4816(M8), Nicrobell® (M10) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) * Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
C1, C6
3, 4.5
COMECO reserves the right of changing specifications without prior notice!
MI Design
temperature probes
Ordering code
TS (L) - (MI -) G0.G1G2.G3.G4.G5.G6.G7'.G7".G9.G10'.G10".G11 - #1
Code Feature or option
Code values
Base model variant
Z - standard (w/ terminal block), OZ - prepared for in-head transmitter (w/o terminal block)
Protection head
B - type "B", CC - type "CC", CS - type "CS", D - type "D", DH - type "DH", DHW - type "DHW", DW - type "DW", E - type "E", EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", ES - type "ES", G - type "G", MA - type "MA", MB - type "MB", N - type "N"
G1
Number of thermocouples
1 or 2
G2
Thermocouple Check wire-to-sheath compatibility in the specification table!
G0
regular design MI design
B - type "B", K - type "K", N - type "N", R - type "R", S - type "S" K - type "K", N - type "N", S - type "S" T5 - 0…1500 °C, T6 - 0…1200 °C, T13 - 0…1000 °C, T14 - 0…1600 °C, T15 - 0…1700 °C, T16 - 0…1100 °C, T21 - 0…1300 °C
G3
Temperature range
G4
Diameter 'd' [mm]
G5
Diameter 'D' [mm]
16, 22, 24, 30, 32, 36, 40
G6
Probe length 'n' [mm]
200…1800 (see table overleaf)
G7'
Probe length 'm' [mm]
100…1000
G7"
Probe length 'm1' [mm]
100…1000
G9
Mounting connection
X - no mounting appliances, F - flange (specify!), Z - other connection (specify!)
G10'
Protection tube material
C1 - ceramic Pythagoras 610, C2 - ceramic Oxal 710, C3 - ceramic Alsint 799, C4 - metal-ceramic Ucar®, C5 - silicon carbide, C6 - Hexoloy®, C7 - Syalon
G10"
Extension tube material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
G11
Accuracy class
1 - '1' (3), 2 - '2'
#1
Incorporated devices
X - none, T - in-head transmitter (1), A - local indicator (2)
single tube
10, 15, 16, 17, 19, 22, 23, 24, 25, 28, 32 (see table overleaf)
double tube
24/10, 24/15, etc. (see 'Accessories - Protection Tubes YA' for available combinations!)
(1)
Only for variant 'OZ'! See transmitter datasheets and order separately! With windowed head only! See indicator datasheets and order separately! (3) Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes (MI) T/C PROBE WITH PROTECTION HEAD AND CERAMIC PROTECTION TUBE
TSZx
- FOR IN-HEAD TRANSMITTER ** TSOZx Holding tube - stainless steel 1.4301 or 1.4404 Protection tube - ceramic (see Accessories - Protection tubes) Head - aluminum, stainless steel, iron, or plastic (see Appendix - Protection heads)
WIRE [mm] SENSITIVE TEMPERATURE TUBE / ELEMENT RANGE MATERIAL MI [mm]
DIMENSIONS d [mm]
D [mm]
Regular Design T13
STRAIGHT DESIGN (TS(O)Z)
T6
0...1000 °C 0...1200 °C
1.0
C1(2),C6
10
16
C1(2)
15
22
C6, C7
16, 19
22, 24
C5
17
24
C1(2)
24
32
C4, C7
22, 28
30, 36
C5
23
30
C6
25, 32
32, 40
C1(2)
10,15,24
16,22,32
C4
22
30
C5
17, 23
24, 30
1.5
1 x K; 1 x N 2 X K, 2 X N T6
T21
0...1200 °C
0...1300 °C
3.0
0.35
C6 10,16,19,25 16,22,24,32 1 x S; 1 x R 2 X S, 2 X R T5
ANGLED DESIGN (TS(O)ZL)
0...1500 °C
0.35, 0.5
T14
0...1600 °C
0.5
1 x B; 2 x B
T14
0...1600 °C
0.35
1 x B; 2 x B
T15
0...1700 °C
0.5
T16
0...1100 °C
C7*
16,22,28
22,30,36
C1(2)
10,15,24
16,22,32
C5
17, 23
24, 30
C6 10,16,19,25 16,22,24,32 C2
10,15,24
16,22,32
C6 10,16,19,25 16,22,24,32 C2
10,15,24
16,22,32
C6 10,16,19,25 16,22,24,32 C3
10,15,24
16,22,32
C6* 10,16,19,25 16,22,24,32
1 x K; 1 x N 2 X K, 2 X N
T16 0...1100 °C (Inconel 600) T6 0...1200 °C (Nicrobell®)
1 x S, 2 x S
n = 200…nmax nmax can be defined from the table below: n [mm] ≤ 400 ≤ 800 ≤ 1800
d≤ single L - 50 L - 70 L - 100
16 double L - 70 L - 100 L - 100
d ≤ 32 any L - 100 L - 100 L - 100
where 'L' is the length of the protection tube (see Accessories - Protection Tubes) Holding tube: - m1 = 100…1000 mm - OD 20(22) mm - tube/elbow material 1.4301 or 1.4541
T16 0...1100 °C (Inconel 600)
10
16
C1
15
22
C6, C7
16, 19
22, 24
C5
17, 23
24, 30
3, 4.5, 6, 8, 10
C1
24
32
C4, C7
22, 28
30, 36
C6
25, 32
32, 40
3, 4.5
C1, C6
10
16
C1
15
22
C6, C7
16, 19
22, 24
C5
17, 23
24, 30
3, 4.5, 6, 8
3, 4.5, 6
Protection head: B, MA, MB, G, N, Cx, Dx, Ex (see Appendix - Protection Heads) Process connection: - welded or adjustable flange - w/o mounting appliances Extension length: m = 100…1000 mm Extension tube material: 1.4301(M1), 1.4541(M2), 1.4404(M9), 1.4571(M3) MI sheath material: 2.4816(M8), Nicrobell® (M10) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) * Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
C1, C6
3, 4.5
COMECO reserves the right of changing specifications without prior notice!
MI Design
temperature probes
Ordering code
TS (L) - (MI -) G0.G1G2.G3.G4.G5.G6.G7'.G7".G9.G10'.G10".G11 - #1
Code Feature or option
Code values
Base model variant
Z - standard (w/ terminal block), OZ - prepared for in-head transmitter (w/o terminal block)
Protection head
B - type "B", CC - type "CC", CS - type "CS", D - type "D", DH - type "DH", DHW - type "DHW", DW - type "DW", E - type "E", EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", ES - type "ES", G - type "G", MA - type "MA", MB - type "MB", N - type "N"
G1
Number of thermocouples
1 or 2
G2
Thermocouple Check wire-to-sheath compatibility in the specification table!
G0
regular design MI design
B - type "B", K - type "K", N - type "N", R - type "R", S - type "S" K - type "K", N - type "N", S - type "S" T5 - 0…1500 °C, T6 - 0…1200 °C, T13 - 0…1000 °C, T14 - 0…1600 °C, T15 - 0…1700 °C, T16 - 0…1100 °C, T21 - 0…1300 °C
G3
Temperature range
G4
Diameter 'd' [mm]
G5
Diameter 'D' [mm]
16, 22, 24, 30, 32, 36, 40
G6
Probe length 'n' [mm]
200…1800 (see table overleaf)
G7'
Probe length 'm' [mm]
100…1000
G7"
Probe length 'm1' [mm]
100…1000
G9
Mounting connection
X - no mounting appliances, F - flange (specify!), Z - other connection (specify!)
G10'
Protection tube material
C1 - ceramic Pythagoras 610, C2 - ceramic Oxal 710, C3 - ceramic Alsint 799, C4 - metal-ceramic Ucar®, C5 - silicon carbide, C6 - Hexoloy®, C7 - Syalon
G10"
Extension tube material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
G11
Accuracy class
1 - '1' (3), 2 - '2'
#1
Incorporated devices
X - none, T - in-head transmitter (1), A - local indicator (2)
single tube
10, 15, 16, 17, 19, 22, 23, 24, 25, 28, 32 (see table overleaf)
double tube
24/10, 24/15, etc. (see 'Accessories - Protection Tubes YA' for available combinations!)
(1)
Only for variant 'OZ'! See transmitter datasheets and order separately! With windowed head only! See indicator datasheets and order separately! (3) Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
ANGLED RTD PROBE WITH PROTECTION HEAD FOR PROTECTION TUBE ASSEMBLY
LDx (TSLDx)
(FOR IN-HEAD TRANSMITTER)** OLDx (TSOLDx) Holding tube - stainless steel 1.4301 or 1.4404 Protection tube - metal (see Accessories - Protection tubes) Head - aluminum, stainless steel, or plastic (see Appendix - Protection heads)
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
2 x Pt (RB,RD,RF,RG)
T9 T1 T11 T2 T4
1 x Cu (RH, RK)
T9
1 x Pt (RB,RD,RF,RG)
2 x Cu (RH, RK)
T9
-50...200 °C -50...400 °C -50...600 °C -200...600 °C -0...800 °C
d [mm]
wires
6
2, 3, 4*
8, 10, or bare
2, 3, 4
6*, 8, 10, or bare
2x2
6 or bare
2, 3
8, 10, or bare
2, 3, 4*
8, 10, or bare
2x2
-50...200 °C
-50...200 °C
Protection head: B, MA, MB, G, N, Dx, Ex, EX (see Appendix - Protection heads) Process connection (must fit the YA connection 'G'): G1/2"(Q4), G3/4"(Q6), male or female (see Accessories - Protection tubes) Insertion length (must fit the YA length 'L'): n = 100…1000 mm Holding tube: - m1 = 100…1000 mm - OD 20(22) mm - tube/elbow material 1.4301 or 1.4541 Tip shape: standard, narrowed, pitted (see Appendix - Tip shapes) Process pressure: YA protection tube process pressure (see Accessories - Protection tubes) Sheath material: 1.4301(M1), 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362 (M15), or bare sensor Wire material: Cu, Ni, or Ag Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance)
d [mm]
M1, M3, M4, M6, M6S, M8, M9, M11, M13, M14
6, 8, 10
M12
6, 8
M20
6
* Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Protection Tube Material
20...25
60...100
Spring-loaded adapter: (mounted between protection tube and elbow)
temperature probes
Ordering code
TS - G0.G1G2.G3.G4.G6.G7.G9.G10.G11.G12.G13.G14 - #1.#2
Code Feature or option
Code values
Base model variant
LD - standard (w/ terminal block), OLD - prepared for in-head transmitter (w/o terminal block)
G0
Protection head
B - type "B", MA - type "MA", MB - type "MB", G - IP65, type "G", N - type "N", D - type "D", DW - windowed, type "DW", DH - w/ high cap, type "DH", DHW - windowed, type "DHW", E - IP65, type "E", ES - stainless-steel, type "ES", EG - IP68 ATEX-approved, type "EG", EGS - IP66 ATEX-approved, type "EGS", EGW - windowed ATEX-approved, type "EGW", EX - explosion-proof instrument housing (specify!)
G1
Number of RTD sensors
1, 2, or 3 (5)
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100
G3
Temperature range
T1 - -50…400 °C, T2 - -200…600 °C (Ni or Ag wires only!), T4 - 0…800 °C (Ag wires only!), T9 - -50…200 °C, T11 - -50…600 °C (Ni or Ag wires only!)
G4
Diameter 'd' [mm] (must fit the protection tube ID)
X (bare sensor), 6, 8, 10
G6
Probe length 'n' [mm]
100…1000
G7
Probe length 'm1' [mm]
100…1000
G9
Mounting connection (must fit the protection tube thread)
Q4 - G1/2", Q6 - G3/4", U4 - G1/2-F", U6 - G3/4-F"
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404, M15 - 1.4362
G11
Accuracy class (1)
A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (5)
(1)
G13
Wire material
G14
Tip shape
CU - copper, NI - nickel, AG - silver X - standard closed, N - narrowed, P - pitted (2)
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled, secured screws), OA - spring-loaded adapter (3), OP - electrochemically polished sheath surface
#2
Local indicator
X - none, A - local indicator mounted (4)
(1)
Only for Pt sensors! Only for non-explosion-proof RTDs! Not available for bare sensor! (4) With windowed head only! See indicator datasheets and order separately! (5) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes ANGLED T/C PROBE WITH PROTECTION HEAD FOR PROTECTION TUBE ASSEMBLY
LDx (TSLDx)
(FOR IN-HEAD TRANSMITTER)** OLDx (TSOLDx) Holding tube - stainless steel 1.4301 or 1.4404 Protection tube - metal (see Accessories - Protection tubes) Head - aluminum, stainless steel, or plastic (see Appendix - Protection heads)
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
wire ø [mm]
d [mm]
wires
Regular Thermocouple Design 8
1
10
1.5
bare
1, 1.5, 3
1 x J; 2 x J 0...800 °C
T4 1 x L; 2 x L
1 x K; 2 x K
1 x E; 2 x E
1 x S; 2 x S 1 x R; 2 x R
T3 T16 T6*
0...850 °C 0...1100 °C 0...1150 °C
T3 T13
0...850 °C 0...1000 °C
T16 T6* T21
0...1100 °C 0...1150 °C 0...1300 °C
10
1.5
bare
1.2, 3.2
8
1
10
1.5
bare
1, 1.5, 3
8
1
10
1.5
bare
1, 1.5, 3
8, 10, or bare
0.35, 0.5
2; 2x2
2; 2x2
2; 2x2
2; 2x2
2; 2x2
MI Thermocouple Design 1xJ 2xJ 1xK 1 x N; 1 x E 2xK 2 x N, 2 x E
T4
0...800 °C
3, 4.5, 6, 8
T3 T16 T6* T6*
0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C
3, 4.5, 6, 8, 10
2 2x2 2 2x2
Protection head: B, MA, MB, G, N, Dx, Ex, EX (see Appendix - Protection heads) Process connection (must fit the YA connection 'G'): G1/2"(Q4), G3/4"(Q6), male or female (see Accessories - Protection tubes) Insertion length (must fit the YA length 'L'): n = 100…1000 mm Holding tube: - m1 = 100…1000 mm - OD 20(22) mm - tube/elbow material 1.4301 or 1.4541 Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip shapes)
Protection Tube Material
Sheathed T/C max. d [mm]
Bare T/C max. ø [mm]
M11, M14
10
4 x ø3
M3, M4, M6, M6S, M8, M9
10
2 x ø3
Sheath material: 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362 (M15) MI sheath material: 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4876(M7), 2.4816(M8), Nicrobell® (M10) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)
* Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
20...25
60...100
Spring-loaded adapter: (mounted between protection tube and elbow)
COMECO reserves the right of changing specifications without prior notice!
Process pressure: YA protection tube process pressure (see Accessories - Protection tubes)
temperature probes
Ordering code
TS - G0.G1G2.G3.G4.G6.G7.G9.G10.G11.G14 - #1.#2
Code Feature or option
Code values
Base model variant
LD - standard (w/ terminal block), OLD - prepared for in-head transmitter (w/o terminal block)
G0
Protection head
B - type "B", MA - type "MA", MB - type "MB", G - IP65, type "G", N - type "N", D - type "D", DW - windowed, type "DW", DH - w/ high cap, type "DH", DHW - windowed, type "DHW", E - IP65, type "E", ES - stainless-steel, type "ES", EG - IP68 ATEX-approved, type "EG", EGS - IP66 ATEX-approved, type "EGS", EGW - windowed ATEX-approved, type "EGW", EX - explosion-proof instrument housing (specify!)
G1
Number of thermocouples
1 or 2
G2
Thermocouple
J - type "J", K - type "K", N - type "N", E - type "E", L - type "L", S - type "S", R - type "R"
G3
Temperature range
T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (4), T13 - 0…1000 °C, T16 - 0…1100 °C, T21 - 0…1300 °C
G4
Diameter 'd' [mm] (must fit the protection tube ID)
G6
Probe length 'n' [mm]
100…1000
G7
Probe length 'm1' [mm]
100…1000
G9
Mounting connection (must fit the protection tube thread)
Q4 - G1/2", Q6 - G3/4", U4 - G1/2-F", U6 - G3/4-F"
G10
Sheath material
regular T/C
X (bare thermocouple), 8, 10
MI T/C
3, 4.5, 6, 8, 10
regular T/C
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762, M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4404, M15 - 1.4362
MI T/C
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®
G11
Accuracy class
1 - '1' (4), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction (1), O - open-tube design (1)
#1
Options
X - none, OV - vibration proof (spring-type terminals (4), secured screws), OA - spring-loaded adapter (2), OP - electrochemically polished sheath surface
#2
Local indicator
X - none, A - local indicator mounted (3)
(1)
Only for non explosion-proof thermocouples! Not available for bare thermocouple! (3) With windowed head only! See indicator datasheets and order separately! (4) Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
(MI) RTD PROBE WITH DETACHABLE CONNECTOR
TSKx
Sheath - stainless steel (see Appendix - Sheath materials) Connector - IP65/68 (see Appendix - Sensor connectors)
SENSITIVE ELEMENT
DIMENSIONS
TEMPERATURE RANGE
n [mm]
d [mm]
wires
Regular Design
DESIGN WITHOUT EXTENSION (TSK) 1 x Pt (RB,RD,RF,RG) 2 x Pt (RB,RD,RF,RG) 3 x Pt * (RB,RD,RF,RG)
T9 T1 T24 T11 T2 T4 T22
1 x Cu (RH, RK) -50...200 °C
T9 2 x Cu (RH, RK)
-50...100 °C
T12
2 x PTC (RP, RQ)
2, 3*
5
2, 3
50…1500
6
2, 3, 4*
50…3000
8, 10, 12, 14
2, 3, 4
50…3000
6*, 8, 10, 12, 14
2x2(3)*
50…3000
8, 10, 12, 14
3x2
50…1500
6
50…3000
8, 10, 12, 14
50…3000
EXTENDED DESIGN WITH WELDED CONNECTION (TSK1) 1 x PTC (RP, RQ)
4
50…500
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C
2, 3, 4*
8, 10
2x2
12, 14
2x2(3)*
50…1500
6
50…3000
8, 10, 12, 14
50…3000
8, 10, 12, 14
2, 3 2x2
MI Design 1 x Pt (RB,RD,RF,RG)
2 x Pt (RB,RD,RF,RG)
EXTENDED DESIGN WITH MOVABLE CONNECTION (TSK2)
T9 T1 T24 T11 T2 T4 T22
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C
3*
2, 3*
4.5
2, 3*
6
2, 3, 4*
8
2, 3, 4
6, 8
2x2, 2x3*
50...50000
50...50000
Detachable wiring connector: C1, C7, C8 (see Appendix - Connectors) Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1
DESIGN WITH ADJUSTABLE CONNECTION (TSK3)
Extension length: m = 0...1500 mm Probe diameter 'd' Ext. length 'm' up to 50 mm 50...150 mm 150...500 mm 500+ mm
3, 4 mm
4.5...6 mm
8 mm
10 mm
10+ mm
8 8 10 14
d 8 10 14
d d 10 14
d d d 14
d d d d
Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes) Process pressure:
DESIGN WITH GLAND-TYPE CONNECTION (TSK4)
Probe design Max. pressure *
TSK, TSK1
TSK2
TSK4
TSK3
25 bar
16 bar
6 bar
0 bar
Sheath material: 1.4301(M1), 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362(M15) Wire material: Cu, Ni, or Ag Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) * Please contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Extension diameter: (for TSK1 and TSK2 only, [mm])
temperature probes
Ordering code
TSK(1,2,3,4) - (MI -) G1G2.G3.G4.G6.G7.G9'9".G10.G11.G12.G13.G14.G15 - #1
Code Feature or option
Code values
G1
Number of RTD sensors (1)
1, 2, or 3 (10)
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP - PTC 1k, RQ - PTC 2k
G3
Temperature range
T1 - -50…400 °C, T2 - -200…600 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C, T22 - -200…200 °C, T24 - -50…500 °C
G4
Diameter 'd' [mm]
G6
Probe length 'n' [mm] (2)
50…50000 (see table overleaf)
G7
Probe length 'm' [mm] (3)
0…1500
G9'
Mounting connection
X - no mounting appliances (4), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9"
Compression fitting ferrule (5)
BR - brass, GR - graphite, SS - stainless steel, TF - Teflon®
G10
Sheath material (wetted parts)
G11
Accuracy class
X - none (6), A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (10)
G13
Wire material (7)
CU - copper (8), NI - nickel, AG - silver (9)
G14
Tip shape
X - standard closed, N - narrowed (9), P - pitted (9)
G15
Wiring connector
C1 - 4-pin connector M12 (IP68), C7 - DIN 43650 4-pin connector (IP65), C8 - DIN 43651 6-pin connector (IP65)
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled) (9), OP - electrochemically polished wetted parts (9)
regular design
4, 5, 6, 8, 10, 12, 14
MI design
3 (10), 4.5, 6, 8
regular design
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404), M15 - 1.4362
MI design
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404)
(1)
The total number of wires must comply with the selected wiring connector! 'n+m' for TSK3 and TSK4! (3) Only for TSK1 and TSK2! (4) Only for TSK! (5) Only for TSK4! (6) For non-Pt sensors (7) Only for Pt sensors! (8) Not applicable to non-MI (regular) RTDs for above 500 °C! (9) Only for non-MI (regular) design! (10) Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
OUTDOOR RTD PROBE WITH ANCHOR BOLT
TSCA SENSITIVE ELEMENT
Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum (see Appendix - Protection heads)
TEMPERATURE RANGE
DIMENSIONS d [mm]
wires
4
2
5
2, 3*
6
2, 3, 4*
1 x Pt (RB,RD,RF,RG)
T12
-50...100 °C
2 x Pt (RB,RD,RF,RG)
T12
-50...100 °C
6
2x2
1 x Cu (RH, RK)
T12
-50...100 °C
5, 6
2, 3
2 x Cu (RH)
T12
-50...100 °C
6
2x2
1 x PTC (RP, RQ)
T12
-50...100 °C
6
2
Protection head: MA, MB (see Appendix - Protection Heads) Mounting accessories: Zn-plated anchor bolt (ø8) w/ rubber sealed clamp (ø20) Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes)
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) n = 40 … 180 mm
Filling: silicone grease (except pitted version) Protection tube: PVC, ø20x2 Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance)
* Please contact COMECO!
TSCA - G0.G1G2.G4.G6.G10.G11.G12.G14
Code Feature or option
Code values
G0
Protection head
MA - type "MA", MB - type "MB"
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP -PTC 1k, RQ - PTC 2k
G4
Diameter 'd' [mm]
4, 5, 6
G6
Anchor bolt length 'n' [mm]
40…180 (step 10 mm)
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
G11
Accuracy class (1)
A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (2)
G14
Tip shape
X - standard closed, N - narrowed, P - pitted
(1) (2)
Only for Pt sensors! Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
temperature probes
RTD PROBE FOR MEAT CUTTING MACHINES
TSCC
Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum or stainless steel (see Appendix - Protection heads)
SENSITIVE ELEMENT
TEMPERATURE RANGE
WIRES
1 x Pt (RB,RD,RF,RG)
T9
-50...200 째C
2, 3, 4
2 x Pt (RB,RD,RF,RG)
T9
-50...200 째C
2x2, 2x3*
1 x Cu (RH, RK)
T9
-50...200 째C
2, 3, 4
2 x Cu (RH)
T9
-50...200 째C
2x2, 2x3*
Protection head: B, MA, MB, D, G, ES (see Appendix - Protection Heads) Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Filling: silicone grease Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) * Please contact COMECO!
Ordering code
TSCC - G0.G1G2.G10.G11.G12 - #1
Code Feature or option
Code values
G0
Protection head
B - type "B", MA - type "MA", MB - type "MB", D - type "D", G - type "G", ES - type "ES"
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100
G10
Sheath material (1)
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
G11
Accuracy class
G12
Number of wires
2, 3, 4 (2)
#1
Options
X - none, OP - electrochemically polished sheath surface
(2)
Only for Pt sensors! Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(1)
A - 'A', B - 'B', C - '2xB'
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes Outdoor RTD Probe (Transmitter) TS(O)P ♦ ♦ ♦ ♦ ♦ ♦
Low cost Ptx sensitive element 2-wire 4…20 mA output available IP66 protection class Robust aluminum enclosure Ready to use - no adjustments
The outdoor temperature probes TSP and TSOP measure temperature by means of a Ptx sensitive element mounted in a thin stainless steel stem for fast response. The TSOP model, in addition, converts the measured temperature into standard 4...20 mA 2-wire signal. Both models are enclosed in a freely mountable robust aluminum enclosure with IP66 protection class and are equipped with a PG7 cable gland for stable and protected electrical decoupling. Five different temperature measurement ranges from -50 °C and up to 100 °C as well as customer specified ranges are available. Thanks to their simplicity, small size, and affordable price, TSP and TSOP are applicable for various outdoor applications, environment temperature control, climatic temperature measurement, etc.
Technical specifications Input
Power supply
Incorporated RTD Measurement range
Pt100 or Pt1000 (w=1.385) -50...50 °C; 0...50 °C; -20...60 °C; 0...100 °C (1); -50...100 °C (1) minimum span 50 °C (transmitter only)
Range on request
Output Signal type Linearity proportional to Output at sensor burnout Output at sensor shorted
Accuracy Electronic measurement error RTD measurement error Non-linearity Self-heating error Temperature drift (2)
Operating conditions Ambient temperature Ambient humidity EM compatibility
-30...65 °C 5...95 %RH according to EN 61326
Design and materials Stem diameter Stem length Sensor sheath Housing material Wiring Mounting Protection class
4 mm 20...60 mm
5 mm 60...200 mm stainless steel aluminum PG7 metal cable gland free IP66
Not available for TSOP Which is greater
Ordering code
TS(O)P - G2.G3.G6.G11 - #1
Code Feature or option
(3)
(transmitter only) 0.2% from span or 0.2 °C (2) according to accuracy class within measurement error 0.02%/mA at 24 V 0.02% from span for 1 °C
10...32 VDC 1 Vp-p at 50 Hz 750 Ω at 24V/20mA
Code values
G2
Sensor (3)
RD - Pt100, RG - Pt1000
G3
Temperature range
T10 - -20...60 °C, T17 - -50...50 °C, T18 - 0...50 °C, T19 - 0...100 °C (1), T12 - -50...100 °C (1), TZ - other (specify, ΔT ≥ 50 °C)
G6
Stem length 'n' [mm]
20…200 (see table above)
G11
Accuracy class
A - 'A', B - 'B', C - '2xB'
#1
Options
X - none, OP - electrochemically polished sheath surface
Do not code for TSOP
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(1)
4...20 mA, 2-wire measured value 32 mA 0.2 mA
Loop voltage Admissible variations Maximum line load
temperature probes Indoor RTD Probe (Transmitter) TS(O)R ♦ ♦ ♦ ♦ ♦ ♦
Low-cost variant for budget applications Ptx sensitive element 2-wire 4…20 mA output available Easy & Fast connection plug Ready to use - no adjustments DIN-rail accessory available
The indoor temperature probes TSR, TSR1, TSOR, and TSOR1 perform fast temperature measurement by means of a Ptx sensitive element mounted in a copper sheath or inside the housing. The TSOR and TSOR1 variants, in addition, convert the measured temperature into standard 4...20 mA 2-wire signal. All variants are enclosed in a freely mountable small plastic box that may also be mounted on a DIN rail when an optional mounting clamp is installed. TSR and TSOR are also equipped with a 3-pin plug-in terminal that allow fast and easy electrical decoupling. Five different temperature measurement ranges from -50 °C and up to 100 °C as well as customer specified ranges are available. Thanks to their simplicity, small size, and affordable price, TSR, TSR1, TSOR, and TSOR1 are applicable for various indoor applications, room temperature control, control board temperature measurement, etc.
Technical specifications Input
Power supply
Incorporated RTD Measurement range Range on request
Output Signal type Linearity proportional to Output at sensor burnout Output at sensor shorted
Pt100 or Pt1000 (w=1.385) -50...50 °C; 0...50 °C; -20...60 °C; 0...100 °C (1); -50...100 °C (1) minimum span 50 °C (transmitter only) 4...20 mA, 2-wire measured value 32 mA 0.2 mA
Accuracy
(transmitter only)
Electronic measurement error RTD measurement error Non-linearity Self-heating error Temperature drift (2) (3)
Ambient temperature Ambient humidity Directives
Design and materials Sensor sheath Housing material Wiring Mounting Dimensions Weight Protection class
-30...65 °C 5...85 %RH CE (2004/108/EC), LVD (2006/95/EC) TS(O)R TS(O)R1 copper none (hidden sensor) plastic plastic plug-in terminal hidden terminal free (3) free (3) 40x75x26 mm 40x75x26 mm (w/o terminal) max. 30 g max. 45 g IP20 IP44 (excl. terminal)
Not available for TSOR and TSOR1. Which is greater DIN-rail mounting accessory is also available (see 'Accessories')
Ordering code
TS - G2.G3.G11
Code Feature or option
Code values
Variant
R - RTD probe, R1 - low-cost RTD probe, OR - temperature transmitter, OR1 - low-cost temperature transmitter
G2
Sensor (4)
RD - Pt100, RG - Pt1000
G3
Temperature range
T10 - -20...60 °C, T17 - -50...50 °C, T18 - 0...50 °C, T19 - 0...100 °C (1), T12 - -50...100 °C (1), TZ - other (specify, ΔT ≥ 50 °C)
G11
Accuracy class
A - 'A', B - 'B', C - '2xB'
(4)
Operating conditions
Do not code for TSOR and TSOR1.
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(1)
0.2% from span or 0.2 °C (2) according to accuracy class within measurement error 0.02%/mA at 24 V 0.02% from span for 1 °C
10...32 VDC 1 Vp-p at 50 Hz 750 Ω at 24V/20mA
Loop voltage Admissible variations Maximum line load
temperature probes RTD Probe with Current Output TSOK ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
Pt100 or Pt1000 sensitive element 2-wire 4…20 mA output Easy & Fast connection plug M12 Vibration-proof design Small dimensions Extended design for higher temperature available High protection class - IP65 Local indicator available
TSOK measures temperature by the means of a Ptx sensitive element and converts it into standard 4...20 mA 2-wire current signal. This transmitter has a robust vibration-proof stainless steel sheath with IP65 protection class, and is equipped with a DIN 43650 connector that allows fast and easy electrical decoupling. The probe interior is filled with special compound, which protects the electronics from the harsh ambient influences. Eight different temperature measurement ranges from -50 °C and up to 400 °C as well as customer specified ranges are available. Various stem diameters and lengths as well as stainless steel types are also available. A local loop-powered indicator TI200 can be optionally mounted between the sheath top and the connector. Thanks to its small size and robust design, TSOK is applicable for cars, rail vehicles, construction machines, and other industrial equipment.
Technical specifications Input
Power supply
Input (RTD) type Measurement range
Pt100 or Pt1000 (w=1.385), class B -50...50 °C; -20...60 °C; 0...50 °C; 0...100 °C; -50...100 °C; 0...150 °C; 0...200 °C; 0...300 °C (1); 0...400 °C (1,5) minimum span 50 °C
Range on request
Output Signal type Linearity proportional to Output at sensor burnout Output at sensor shorted
4...20 mA, 2-wire measured value 32 mA 0.2 mA
Accuracy 0.2% from span or 0.2 °C (2) within measurement error 0.01% from span for 1 °C
Measurement error Non-linearity Temperature drift
(2)
max. 25 bar -40...85 °C 0...98 %RH according to EN 61000, EN 61010
Design and materials Sensor sheath Wiring Mounting thread Stem diameter Stem length Extension length (1) Protection class
stainless steel 4-pin detachable connector DIN 43650 M16, M18, M20, 3/8”, 1/2”, or other 6 or 8 mm 20...300 mm 50...100 mm IP65
Code values
Variant
K - short-design, K1 - extended-design
G3
Temperature range
T17 - -50...50 °C, T10 - -20...60 °C, T18 - 0...50 °C, T19 - 0...100 °C, T12 - -50...100 °C, T20 - 0...150 °C, T7 - 0...200 °C, T23 - 0...300 °C (1), T8 - 0...400 °C (1,5), TZ - other (specify, ΔT ≥ 50 °C)
G4
Stem diameter 'd' [mm]
6, 8
G6
Stem length 'n' [mm]
20 (3)…300 (step 5 mm)
G7
Extension length 'm' [mm] (1)
G9
(5)
Medium pressure Ambient temperature Ambient humidity EM compatibility and safety
TSO - G3.G4.G6.G7.G9.G10.G14 - #1.#2
Code Feature or option
(4)
Operating conditions
Only for the extended-design variant! Which is greater
Ordering code
(3)
10...32 VDC 1 Vp-p at 50 Hz 750 Ω at 24V/20mA
Mounting thread
50…100 (step 5 mm)
cylindrical (15 mm length)
Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", QZ - other (specify!)
tapered (standard length)
Q9 - 3/8" NPT, Q10 - 1/2" NPT, QZ - other (specify!)
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
G14
Tip shape
X - standard closed, N - narrowed
#1
Options
X - none, OP - electrochemically polished sheath surface
#2
Local indicator TI200
X - none, A - local indicator TI200 (4)
Minimum thread length + 5 mm! See TI200 specifications and order separately! Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(1)
Loop voltage Admissible variations Maximum line load
temperature probes Programmable RTD Probe with Current Output TSOJ ♦ ♦ ♦ ♦ ♦ ♦ ♦
Programmable conversion range 2-wire 4…20 mA output Easy & Fast connection plug Straight or angled cable connector Small dimensions Vibration-proof design High protection class - IP65
TSOJ measures temperature within the -50...200 °C range via a Pt100 sensitive element and converts it into standard 4...20 mA 2-wire signal. The configuration software "TraCon" enables programming of the measurement range and output direction as well as other parameters. The probe has a robust vibration-proof stainless steel sheath with IP65 protection class, and its interior is filled with special compound, which protects the electronics from the harsh ambient influences. TSOJ is equipped with a detachable connector that allows fast and easy electrical decoupling. Various stem diameters and lengths as well as stainless steel types are available. Thanks to its robust design and flexible programming, the TSOJ probe is a fast and convenient solution to varying problems involving temperature measurement and conversion in industrial environments.
Technical specifications Input Input (RTD) type Measurement range Minimum programmable span
Output Signal type Maximum load Sensor failure reaction
(programmable) Pt100 (w=1.385) min. -50...max. 200 °C, programmable 50 °C (programmable) 4...20 mA or 20...4 mA, 2-wire 800 Ω at 24V/20mA < 3.9 or > 20.2 mA, programmable
Accuracy
Power supply 10...32 VDC 1 Vp-p at 50 Hz
Loop voltage Admissible variations
RS232, requiring special cable (2) "TraCon", free
Operating conditions Medium pressure Ambient temperature Ambient humidity EM compatibility
max. 25 bar -20...70 °C 0...95 %RH, non-condensing according to EN 61326
Case material Wiring Dimensions Mounting thread Stem diameter Stem length Protection class
stainless steel 4-pin detachable connector M12 or DIN 43650 (incl. female part) ø30x max. 66 mm (w/o stem and connector) M16, M18, M20, 3/8”, 1/2”, or other 6 or 8 mm 20...300 mm, step 5 mm IP65
Which is greater Ordered separately
Ordering code
TSOJ - G4.G6.G9.G10.G11.G14.G15 - #1
Code Feature or option
Code values
G4
Stem diameter 'd' [mm]
6, 8
G6
Stem length 'n' [mm]
20 (3)…300 (step 5 mm)
G9
Mounting thread
cylindrical (15 mm length)
Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", QZ - other (specify!)
tapered (standard length)
Q9 - 3/8" NPT, Q10 - 1/2" NPT, QZ - other (specify!)
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
G11
Accuracy class (4)
A - 'A', B - 'B'
G14
Tip shape
X - standard closed, N - narrowed
G15
Wiring connector
C1A - angled connector M12, C1S - straight connector M12, C7 - DIN 43650 connector
#1
Options
X - none, OP - electrochemically polished sheath surface
(3)
Minimum thread length + 5 mm! (4) Of the built-in Pt100 sensor
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(2)
Interface type Configuration software
Design and materials 0.2% from span or 0.2 °C (1) according to the accuracy class within measurement error 0.01% from span for 1 °C
Measurement error RTD error Non-linearity Temperature drift
(1)
Serial interface
temperature probes
ROOM TEMPERATURE PROBE
TSUM
Case - plastic (ABS)
SENSITIVE ELEMENT
TEMPERATURE RANGE
1 x Pt (RB,RD,RF,RG)
T10
-10...60 °C
1 x Cu (RH, RK)
T10
-10...60 °C
SPECIFIC FEATURES
Room temperature measured value may be adjusted (increased or decreased) by the number pointed on the scale. The following designs exist according to maximum adjustment value: - up to ± 4 °C * - up to ± 8 °C * - up to ± 12 °C *
* Specify when ordering!
Ordering code
TSUM - G2
Code Feature or option Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100
COMECO reserves the right of changing specifications without prior notice!
G2
Code values
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
transmitters Infrared Temperature Transmitter TRU ♦ ♦ ♦ ♦ ♦ ♦ ♦
Low-temperature remote measurement Object temperature range from -10 to 150 °C Field of view 7.3 ° Linear current or voltage output signal Serial interface available Local programmable indicator available IP66 protection class
The TRU temperature transmitter's operation is based on the principle of sensing infrared radiation, emitted from a heated object, situated at a certain distance from the sensor, at a 7.3 ° conical angle. The sensitive thermopile element comprises of a multitude of thermocouples connected in series and allows measurement of the object surface temperature within the -10…150 °C range. The incorporated electronics converts the sensor output into a standard current or voltage signal suitable for further transmission and processing. Moreover, the transmitter may be equipped with programmable local LED indicator as well as with RS232 serial interface for data transmitting. By the means of specialized software, the information about the object's temperature may be viewed, stored, and printed from a PC. TRU is enclosed in a robust plastic box with connector, both with IP66, and is designed to be either freely mounted or mounted on DIN rail via special brackets. The TRU transmitter is very suitable for these special applications that require non-contact low-temperature-object measurement.
Technical specifications Input
Interface
Input type Material emission coefficient Object temperature range Calibrating distance Calibrating spot Field of view
object infrared emission 5...15 μm ≥ 0.85 min. -10...max. 150 °C 5 cm 3.5 cm 7.3 °
Analog output Output signal Output function Accuracy Temperature drift Maximum output load Output overload reaction
0(4)...20 mA or 0...10 V input signal info retransmission 2% from span 0.02% from span for 1 °C 750 Ω at 24V/20 mA display message
Local indicator (option) 3 LED indicators, 14 mm 1 °C 2 membrane keys
Digital display Display resolution Keyboard
Power supply Supply voltage Admissible variations Consumption
15...32 VDC 4 Vp-p at 50 Hz max. 120 mA
Operating conditions Ambient temperature Storage temperature
-10...65 °C -20...85 °C
Design and materials Case material Mounting Wiring Dimensions Weight Protection class
ABS/PC plastic free (1) 4-pin М12 connector 80x92x65 mm max. 250 g IP66
Radial, axial, and DIN-rail mounting accessories for 80x80x60 mm box can be ordered separately (see 'Accessories').
Ordering code
TRU - G9.G11 - #1
Code Feature or option
(2)
RS232 data transmission
Code values
G9
Serial interface
X - none, A - RS232
G11
Analog output
X - none (2), E - 0…20 mA, F - 4…20 mA, K - 0…10 V, Z - other on request
#1
Local indicator (2)
X - none, A - local indicator mounted
When no output is requested, local indicator must be ordered!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(1)
Interface type Function
temperature probes ATEX (MI) RTD PROBE - FOR IN-HEAD TRANSMITTER **
TSCx - EX TSOCx - EX
II 2 G Ex d IIC T6 Gb -20°C≤Ta≤+65°C II 2 D Ex tb IIIC T80 °C Db IP65 EC-type Certificate No. MP 08 ATEX 0002
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
n [mm]
d [mm]
wires
Regular Design
DESIGN WITHOUT EXTENSION (TS(O)C) 1 x Pt (RB,RD,RF,RG)
2(3) x Pt (RB,RD,RF,RG)
for n < 150 mm, contact COMECO!
EXTENDED DESIGN WITH WELDED CONNECTION (TS(O)C1)
T9 T1 T24 T11 T2 T4 T22
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C
1 x Cu (RH, RK)
T9
-50...200 °C
2 x Cu (RH, RK)
T9
-50...200 °C
T12
-50...100 °C
1 x PTC (RP, RQ)
2 x Pt (RB,RD,RF,RG)
EXTENDED DESIGN WITH MOVABLE CONNECTION (TS(O)C2)
T9 T1 T24 T11 T2 T4 T22
4 5
2, 3*
50…1500
6
2, 3, 4*
50…3000 8, 10, 12, 14, 16, 20
2, 3, 4
6*, 8, 10
2x2(3)*
12, 14, 16, 20
2x2(3), 3x2
50…3000 50…1500
6
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C
2, 3, 4*
50…3000 8, 10, 12, 14, 16, 20 8, 10 12, 14, 16, 20 6 8, 10, 12, 14 8, 10, 12, 14
2x2 2x2(3)*
50...50000
3* 4.5 6 8
2, 3* 2, 3* 2, 3, 4* 2, 3, 4
50...50000
6, 8
2x2, 2x3*
50…3000
50…1500 50…3000 50…3000 MI Design
2 x PTC (RP, RQ)
1 x Pt (RB,RD,RF,RG)
50…500
2, 3 2x2
Protection head: EG(SS), EGS, EGW(SS), EX8(SS), EX8W(SS), EX10(SS), EX10W(SS), EX8WD, EX10WD (see Appendix - Protection Heads) Electrical entry: - cable gland(s): SS or brass, cemented, ID 7.5 mm - threaded head conduit(s) Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1
DESIGN WITH ADJUSTABLE CONNECTION (TS(O)C3)
Extension length: m = 0…1500 mm
Probe diameter 'd' Ext. length 'm' up to 50 mm 50...150 mm 150...500 mm 500+ mm
3, 4 mm
4.5...6 mm
8 mm
10 mm
10+ mm
8 8 10 14
d 8 10 14
d d 10 14
d d d 14
d d d d
Tip shape: standard or narrowed (see Appendix - Tip Shapes) Process pressure:
DESIGN WITH GLAND-TYPE CONNECTION (TS(O)C4)
Probe design Max. pressure *
TS(O)C, TS(O)C1 25 bar
TS(O)C2 16 bar
TS(O)C4 6 bar
TS(O)C3 0 bar
Sheath material: 1.4301(M1), 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362(M15) Wire material: Cu, Ni, or Ag Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) * Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Extension diameter: (for TS(O)C1 and TS(O)C2 only, [mm])
temperature probes
Ordering code
TS (1,2,3,4) - (MI -) G0'n0".G1G2.G3.G4.G6.G7.G9'9".G10.G11.G12.G13.G14 - #1.#2 - EX
Code Feature or option
Code values
Base model variant
C - standard (w/ terminal block), OC - prepared for in-head transmitter (w/o terminal block)
G0'
Protection head
EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", EX8 - type "EX8", EX8SS - type "EX8SS", EX8W - type "EX8W", EX8WSS - type "EX8WSS", EX10 - type "EX10", EX10SS - type "EX10SS", EX10W - type "EX10W", EX10WSS - type "EX10WSS", EX8WD - type "EX8WD", EX10WD - type "EX10WD"
G0"
Electrical entry ('n' - number of entries (12))
G - gland, U2 - M20x1.5, U4 - G1/2", U6 - G3/4", U10 - 1/2" NPT, U11 - 3/4" NPT
G1
Number of RTD sensors
1, 2, or 3 (11)
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP - PTC 1k, RQ - PTC 2k
G3
Temperature range
T1 - -50…400 °C, T2 - -200…600 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C, T22 - -200…200 °C, T24 - -50…500 °C
G4
Diameter 'd' [mm]
G6 G7
Probe length 'n' [mm]
regular design
4, 5, 6, 8, 10, 12, 14, 16, 20
MI design
3 (11), 4.5, 6, 8
(1)
Probe length 'm' [mm]
50…50000 (see table overleaf)
(2)
0…1500 X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9'
Mounting connection
G9"
Compression fitting ferrule (4) regular design
BR - brass, GR - graphite, SS - stainless steel, TF - Teflon® M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404), M15 - 1.4362 (11)
G10
Sheath material (wetted parts)
G11
Accuracy class
X - none (5), A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (11)
(6)
MI design
M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404)
CU - copper (7), NI - nickel, AG - silver (8)
G13
Wire material
G14
Tip shape
X - standard closed, N - narrowed (8)
#1
Options
X - none, OV - vibration proof (spring terminals, MgO or Silicone filled, secured screws) (8), OT - thermal isolation (3), OP - electrochemically polished sheath surface (8)
#2
Incorporated devices
X - none, T - in-head transmitter (9), A - local indicator (10)
(1)
'n+m' for TS(O)C3 and TS(O)C4! Only for TS(O)C1 and TS(O)C2! Only for TS(O)C! (4) Only for TS(O)C4! (5) For non-Pt sensors (6) Only for Pt sensors! (7) Not applicable to non-MI (regular) RTDs for above 500 °C! (8) Only for non-MI (regular) design! (9) Only for variant 'OC'! See transmitter datasheets and order separately! (10) With windowed head only! See indicator datasheets and order separately! (11) Contact COMECO! (12) Applicable for the selected head type (see Appendix - Protection Heads) (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes ATEX (MI) T/C PROBE - FOR IN-HEAD TRANSMITTER **
TSCx - EX TSOCx - EX
II 2 G Ex d IIC T6 Gb -20°C≤Ta≤+65°C II 2 D Ex tb IIIC T80 °C Db IP65 EC-type Certificate No. MP 08 ATEX 0002
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
1(2) x J 1(2) x L
T4
0...800 °C
1(2) x K
T3 T16 T6*
0...850 °C 0...1100 °C 0...1150 °C
1(2) x E
T3 T13
0...850 °C 0...1000 °C
50...1500
6
50...3000
8, 10, 12, 14, 16, 20, 22
2 (2x2)
1(2) x S 1(2) x R
T16 T6*
0...1100 °C 0...1150 °C
50...1500 50...3000
6 8, 10, 12, 14, 16, 20, 22
2 (2x2)
T4
0...800 °C
50...50000
3, 4.5, 6, 8, 10*
T8
0...400 °C
50...50000
3, 4.5, 6, 8, 10*
0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C
50...50000
3, 4.5, 6, 8, 10*
2
2xK 2 x N, 2 x E
T3 T16 T6* T6*
50...50000
3, 4.5, 6, 8, 10*
2x2
2xS 2xR
T16 T6*
0...1100 °C 0...1150 °C
50...10000
3, 4.5, 6
2x2
n [mm]
d [mm]
wires
50...1500 50...3000
6 8, 10, 12, 14, 16, 20, 22
2 (2x2)
50...1500
6
50...3000
8, 10, 12, 14, 16, 20, 22
Regular Design
DESIGN WITHOUT EXTENSION (TS(O)C)
for n < 150 mm, contact COMECO!
2 (2x2)
MI Design
EXTENDED DESIGN WITH WELDED CONNECTION (TS(O)C1)
1xJ 2xJ 1xT 2xT 1xK 1 x N, 1 x E
2 2x2 2 2x2
Protection head: EG(SS), EGS, EGW(SS), EX8(SS), EX8W(SS), EX10(SS), EX10W(SS), EX8WD, EX10WD (see Appendix - Protection Heads)
EXTENDED DESIGN WITH MOVABLE CONNECTION (TS(O)C2)
Electrical entry: - cable gland(s): SS or brass, cemented, ID 7.5 mm - threaded head conduit(s) Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Extension length: m = 0…1500 mm Extension diameter: (for TS(O)C1 and TS(O)C2 only, [mm]) Probe diameter 'd' Ext. length 'm' up to 50 mm 50...150 mm 150...500 mm 500+ mm
3 mm
4.5, 6 mm
8 mm
10 mm
10+ mm
6 8 10 14
d 8 10 14
d d 10 14
d d d 14
d d d d
Tip shape (hot junction design): standard (isolated) (see Appendix - Tip Shapes) Process pressure:
DESIGN WITH GLAND-TYPE CONNECTION (TS(O)C4)
Probe design Max. pressure *
TS(O)C, TS(O)C1 25 bar
TS(O)C2 16 bar
TS(O)C4 6 bar
TS(O)C3 0 bar
Sheath material: 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762/1.4749(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362(M15) MI sheath material: 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762/1.4749(M4), 1.4841(M5), 1.4876(M7), 2.4816(M8), Nicrobell®(M10) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) * Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
DESIGN WITH ADJUSTABLE CONNECTION (TS(O)C3)
temperature probes
Ordering code TS (1,2,3,4) - (MI -) G0'n0".G1G2.G3.G4.G6.G7.G9'9".G10.G11 - #1.#2 - EX Code Feature or option
Code values
Base model variant
C - standard (w/ terminal block), OC - prepared for in-head transmitter (w/o terminal block)
G0'
Protection head
EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", EX8 - type "EX8", EX8SS - type "EX8SS", EX8W - type "EX8W", EX8WSS - type "EX8WSS", EX10 - type "EX10", EX10SS - type "EX10SS", EX10W - type "EX10W", EX10WSS - type "EX10WSS", EX8WD - type "EX8WD", EX10WD - type "EX10WD"
G0"
Electrical entry ('n' - number of entries (9))
G - gland, U2 - M20x1.5, U4 - G1/2", U6 - G3/4", U10 - 1/2" NPT, U11 - 3/4" NPT
G1
Number of thermocouples
1 or 2
G2
Thermocouple
G3
Temperature range
G4
Diameter 'd' [mm]
G6
Probe length 'n' [mm] (1)
G7
Probe length 'm' [mm]
regular design
E - type "E", J - type "J", K - type "K", L - type "L", R - type "R", S - type "S"
MI design
E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T" T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (8), T13 - 0…1000 °C, T16 - 0…1100 °C
regular design
6, 8, 10, 12, 14, 16, 20, 22
MI design
3, 4.5, 6, 8, 10 50…50000 (see table overleaf)
(2)
0…1500
G9'
Mounting connection
X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9"
Compression fitting ferrule (4)
BR - brass, GR - graphite, SS - stainless steel, TF - Teflon®
G10
Sheath material (wetted parts)
regular design
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4401 (1.4404), M15 - 1.4362
MI design
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876, M8 - 2.4816, M9 - 1.4401 (1.4404), M10 - Nicrobell®
G11
Accuracy class
1 - '1' (8), 2 - '2'
#1
Options
X - none, OV - vibration proof (spring terminals (8), secured screws), OT - thermal isolation (3), OP - electrochemically polished sheath surface (5)
#2
Incorporated devices
X - none, T - in-head transmitter (6), A - local indicator (7)
(1)
'n+m' for TS(O)C3 and TS(O)C4! Only for TS(O)C1 and TS(O)C2! Only for TS(O)C! (4) Only for TS(O)C4! (5) Only for non-MI (regular) design! (6) Only for variant 'OC'! See transmitter datasheets and order separately! (7) With windowed head only! See indicator datasheets and order separately! (8) Contact COMECO! (9) Applicable for the selected head type (see Appendix - Protection Heads) (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes ATEX RTD PROBE WITH (MI) INSERT - FOR IN-HEAD TRANSMITTER ** II 2 G Ex d IIC T6 Gb -20°C≤Ta≤+65°C II 2 D Ex tb IIIC T80 °C Db IP65
TSCSx - EX TSOCSx - EX
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
d insert [mm]
d [mm]
EC-type Certificate No. MP 08 ATEX 0002
wires
Regular Insert Design
DESIGN WITHOUT EXTENSION (TS(O)CS) 1 x Pt (RB,RD,RF,RG)
2 x Pt (RB,RD,RF,RG) for n < 150 mm, contact COMECO!
1 x Cu (RH, RK) 2 x Cu (RH, RK)
EXTENDED DESIGN WITH WELDED CONNECTION (TS(O)CS1) 1 x Pt (RB,RD,RF,RG)
2 x Pt (RB,RD,RF,RG)
T9 T1 T24 T11 T2 T4 T22
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C -50...200 °C
T9
-50...200 °C
T9
T9 T1 T24 T11 T2 T4 T22
8
4, 5
2, 3*
9, 10, 12, 14, 16, 20
6
2, 3, 4*
12, 14, 16, 20
8
2, 3, 4
9, 10, 12, 14, 16, 20
6
2x2*
12, 14, 16, 20
8
2x2(3)*
9, 10, 12, 14, 16, 20
6
2, 3, 4*
12, 14, 16, 20
8
2, 3, 4
9, 10, 12, 14, 16, 20
6
2x2*
12, 14, 16, 20
8
2x2(3)*
3*
2, 3*
MI Insert Design 6, 8, 9, 10, 12, 14, 16, 20 8, 9, 10, 12, 14, 16, 20 9, 10, 12, 14, 16, 20
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C
4.5
2, 3*
6
2, 3, 4* 2, 3, 4
12, 14, 16, 20
8
9, 10, 12, 14, 16, 20
6
2x2, 2x3*
12, 14, 16, 20
8
2x2, 2x3*
Protection head: EG(SS), EGS, EGW(SS), EX8(SS), EX8W(SS), EX10(SS), EX10W(SS), EX8WD, EX10WD (see Appendix - Protection Heads)
EXTENDED DESIGN WITH MOVABLE CONNECTION (TS(O)CS2)
Electrical entry: - cable gland(s): SS or brass, cemented, ID 7.5 mm - threaded head conduit(s) Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Extension length: m = 0…1500 mm Extension diameter: (for TS(O)CS1 and TS(O)CS2 only, [mm]) Probe diameter 'd' Ext. length 'm'
6 mm
8 mm
9, 10 mm
10+ mm
up to 50 mm
d
d
d
d
50...150 mm
8
d
d
d
150...500 mm
10
10
d
d
500+ mm
14
14
14
d
Tip shape: standard or narrowed (see Appendix - Tip Shapes) Process pressure: Probe design
DESIGN WITH GLAND-TYPE CONNECTION (TS(O)CS4)
Max. pressure *
TS(O)CS, TS(O)CS1 TS(O)CS2 25 bar
16 bar
TS(O)CS4
TS(O)CS3
6 bar
0 bar
Sheath material: 1.4301(M1), 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362(M15) Wire material: Cu, Ni, or Ag Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) * Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
DESIGN WITH ADJUSTABLE CONNECTION (TS(O)CS3)
temperature probes
Ordering code
TS (1,2,3,4) - (MI -) G0'n0".G1G2.G3.G4.G6.G7.G9'9".G10.G11.G12.G13.G14 - #1.#2 - EX
Code Feature or option
Code values
Base model variant
CS - standard (w/ terminal block), OCS - prepared for in-head transmitter (w/o terminal block)
G0'
Protection head
EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", EX8 - type "EX8", EX8SS - type "EX8SS", EX8W - type "EX8W", EX8WSS - type "EX8WSS", EX10 - type "EX10", EX10SS - type "EX10SS", EX10W - type "EX10W", EX10WSS - type "EX10WSS", EX8WD - type "EX8WD", EX10WD - type "EX10WD"
G0"
Electrical entry ('n' - number of entries (13))
G - gland, U2 - M20x1.5, U4 - G1/2", U6 - G3/4", U10 - 1/2" NPT, U11 - 3/4" NPT
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100
G3
Temperature range
T1 - -50…400 °C, T2 - -200…600 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C, T22 - -200…200 °C, T24 - -50…500 °C
G4
Diameter 'd' / 'd insert' [mm]
G6 G7
Probe length 'n' [mm]
regular insert
8/4, 8/5, 9/6, 10/6, 12/6, 14/6, 12/8, 14/8, 16/6, 16/8, 20/6, 20/8
MI insert
6/3 (12), 8/4.5, 9/6, 10/6, 12/6, 14/6, 16/6, 16/8, 20/6, 20/8
(1)
Probe length 'm' [mm]
50…3000
(2)
0…1500 X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9'
Mounting connection
G9"
Compression fitting ferrule (4)
BR - brass, SS - stainless steel, TF - Teflon®
regular insert
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404), M15 - 1.4362 (12)
MI insert
M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404)
G10
Sheath material (wetted parts and insert)
G11
Accuracy class
X - none (5), A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (12)
(6)
CU - copper (7), NI - nickel, AG - silver (8)
G13
Wire material
G14
Tip shape
X - standard closed, N - narrowed (12)
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled insert, secured screws) (8,9), OS - spring-loaded insert, OT - thermal isolation (3), OP - electrochemically polished wetted parts
#2
Incorporated devices
X - none, T - in-head transmitter (10), A - local indicator (11)
(1)
'n+m' for TS(O)CS3 and TS(O)CS4! Only for TS(O)CS1 and TS(O)CS2! Only for TS(O)CS! (4) Only for TS(O)CS4! (5) For non-Pt sensors (6) Only for Pt sensors! (7) Not applicable to non-MI (regular) RTD inserts for above 500 °C! (8) Only for non-MI (regular) inserts! (9) Requires 'OS' option! (10) Only for variant 'OCS'! See transmitter datasheets and order separately! (11) With windowed head only! See indicator datasheets and order separately! (12) Contact COMECO! (13) Applicable for the selected head type (see Appendix - Protection Heads) (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes ATEX T/C PROBE WITH (MI) INSERT - FOR IN-HEAD TRANSMITTER ** II 2 G Ex d IIC T6 Gb -20°C≤Ta≤+65°C II 2 D Ex tb IIIC T80 °C Db IP65
TSCSx - EX TSOCSx - EX
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
d [mm]
EC-type Certificate No. MP 08 ATEX 0002
d insert [mm]
wires
Regular Insert Design
DESIGN WITHOUT EXTENSION (TS(O)CS)
10, 12, 14, 16, 20
6, 8, 10
2
12, 14, 16, 20
8, 10
2x2
0...850 °C 0...1100 °C 0...1150 °C
10, 12, 14, 16, 20
6, 8, 10
2
12, 14, 16, 20
8, 10
2x2
0...850 °C 0...1000 °C
10, 12, 14, 16, 20
6, 8, 10
2
2xE
T3 T13
12, 14, 16, 20
8, 10
2x2
1xS 1xR
T16 T6*
0...1100 °C 0...1150 °C
10, 12, 14, 16, 20
6, 8, 10
2
2xS 2xR
T16 T6*
0...1100 °C 0...1150 °C
12, 14, 16, 20
8, 10
2x2
1 x J; 1 x L 2 x J; 2 x L 1xK 2xK 1xE
for n < 150 mm, contact COMECO!
EXTENDED DESIGN WITH WELDED CONNECTION (TS(O)CS1)
T4
0...800 °C
T3 T16 T6*
MI Insert Design 1xJ 2xJ 1xK 1 x N, 1 x E 2xK 2 x N, 2 x E
T4
0...800 °C
6, 8, 10, 12, 14, 16, 20
3, 4.5, 6, 8
T3 T16 T6* T6*
0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C
8, 10, 12, 14, 16, 20
4.5, 6, 8
2 2x2 2 2x2
Protection head: EG(SS), EGS, EGW(SS), EX8(SS), EX8W(SS), EX10(SS), EX10W(SS), EX8WD, EX10WD (see Appendix - Protection Heads)
EXTENDED DESIGN WITH MOVABLE CONNECTION (TS(O)CS2)
Electrical entry: - cable gland(s): SS or brass, cemented, ID 7.5 mm - threaded head conduit(s) Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Process length: n = 50…3000 mm
DESIGN WITH ADJUSTABLE CONNECTION (TS(O)CS3)
Extension length: m = 0…1500 mm Extension diameter: (for TS(O)CS1 and TS(O)CS2 only, [mm]) 6 mm
8 mm
10 mm
10+ mm
up to 50 mm
d
d
d
d
50...150 mm
8
d
d
d
150...500 mm
10
10
d
d
500+ mm
14
14
14
d
Insert tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Process pressure:
DESIGN WITH GLAND-TYPE CONNECTION (TS(O)CS4)
Probe design Max. pressure *
TS(O)CS, TS(O)CS1 TS(O)CS2 25 bar
16 bar
TS(O)CS4
TS(O)CS3
6 bar
0 bar
Sheath material: 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762/1.4749(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362(M15) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) * Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Probe diameter 'd' Ext. length 'm'
temperature probes
Ordering code TS (1,2,3,4) - (MI -) G0'n0".G1G2.G3.G4.G6.G7.G9'9".G10.G11.G14 - #1.#2 - EX Code Feature or option
Code values
Base model variant
CS - standard (w/ terminal block), OCS - prepared for in-head transmitter (w/o terminal block)
G0'
Protection head
EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", EX8 - type "EX8", EX8SS - type "EX8SS", EX8W - type "EX8W", EX8WSS - type "EX8WSS", EX10 - type "EX10", EX10SS - type "EX10SS", EX10W - type "EX10W", EX10WSS - type "EX10WSS", EX8WD - type "EX8WD", EX10WD - type "EX10WD"
G0"
Electrical entry ('n' - number of entries (9))
G - gland, U2 - M20x1.5, U4 - G1/2", U6 - G3/4", U10 - 1/2" NPT, U11 - 3/4" NPT
G1
Number of thermocouples
1 or 2
G2
Thermocouple
G3
Temperature range
G4
Diameter 'd' / 'd insert' [mm]
G6
Probe length 'n' [mm] (1)
G7
Probe length 'm' [mm]
regular insert
E - type "E", J - type "J", K - type "K", L - type "L", R - type "R", S - type "S"
MI insert
E - type "E", J - type "J", K - type "K", N - type "N" T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (8), T13 - 0…1000 °C, T16 - 0…1100 °C
regular insert
10/6, 10/8, 12/6, 12/8, 14/6, 14/8, 14/10, 16/10, 20/10
MI insert
6/3, 8/4.5, 10/6, 12/6, 14/6, 16/6, 20/6, 20/8 50…3000
(2)
0…1500
G9'
Mounting connection
X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9"
Compression fitting ferrule (4)
BR - brass, SS - stainless steel, TF - Teflon®
G10
Sheath material (wetted parts and insert)
regular insert
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4401 (1.4404), M15 - 1.4362
MI insert
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M8 - 2.4816, M9 - 1.4401 (1.4404)
G11
Accuracy class
1 - '1' (8), 2 - '2'
G14
Insert tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
#1
Options
X - none, OV - vibration proof (secured screws) (5), OS - spring-loaded insert, OT - thermal isolation (3), OP - electrochemically polished wetted parts
#2
Incorporated devices
X - none, T - in-head transmitter (6), A - local indicator (7)
(1)
'n+m' for TS(O)CS3 and TS(O)CS4! Only for TS(O)CS1 and TS(O)CS2! (3) Only for TS(O)CS! (4) Only for TS(O)CS4! (5) Requires 'OS' option! (6) Only for variant 'OCS'! See transmitter datasheets and order separately! (7) With windowed head only! See indicator datasheets and order separately! (8) Contact COMECO! (9) Applicable for the selected head type (see Appendix - Protection Heads)
COMECO reserves the right of changing specifications without prior notice!
(2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
transmitters Fixed-Input Temperature Transmitter TRN ♦ ♦ ♦ ♦ ♦ ♦
Low cost 2- or 3-wire output line connection High resistance to electromagnetic disturbances ZERO and SPAN adjustment In-head and DIN-rail versions IP65 box and Ex housing available
COMECO's current loop transmitter TRN converts the signal from a temperature sensor into standard current or voltage signal that can be safely sent over long distances to remote indicators, data loggers, or controllers. In addition to the most common thermoresistance and thermocouple sensors, TRN may convert linear analog input signals (current or voltage). The transmitter is based on high-tech integral circuits and has fixed input range. Two-wire- and three-wire-output variants are offered. Both are available in case for mounting inside sensor protection head, in watertight box with high protection class, in case for mounting on a DIN rail, and in case prepared for mounting in Ex housings. TRN can withstand considerable electromagnetic disturbances and is a perfect low-cost solution for general-purpose applications.
Technical specifications Input
Accuracy min. -50...max. 500 °C (1) min. -50...max. 250 °C (1) min. -50...max. 250 °C (1) min. -50...max. 500 °C (1) min. 0...max. 1000 °C (1) min. 0...max. 1000 °C (1) min. 0...max. 1300 °C (1) min. 0...max. 800 °C (1) min. 0...max. 800 °C (1) min. 0...max. 400 °C (1) min. 0...max. 600 °C (1) min. 0...max. 20 mA (1) min. 0...max. 10 V (1) RTD: 50 °C, T/C: 250 °C ± 10%
Pt50...1000; 2- or 3-wire Cu100; 2- or 3-wire Cu50; 2- or 3-wire Other thermoresistive Thermocouple "E" Thermocouple "J" Thermocouple "K" Thermocouple "L" Thermocouple "L - GOST" Thermocouple "T" Thermocouple "U" Linear current Linear voltage Minimum input range width ZERO and SPAN adjustment
Output 4...20 mA 0...5 mA, 0(4)...20 mA 0...1/ 2/ 5/ 10 V, 1...5 V, 2...10 V temperature input voltage Low: < 3.5 mA, High: > 23 mA Low or High, depends on terminal High
2-wire current 3-wire current 3-wire voltage RTD linearly proportional to T/C linearly proportional to Current limits Reaction at RTD failure Reaction at T/C failure
Measurement error Non-linearity for RTD input Self-heating error Temperature drift Cold junction compensation
0.3% from span 0.3% from span 0.02%/mA at 24 V 0.02% from span for 1 °C automatic hardware, ± 1 °C
Power supply Supply voltage: - for 2-wire output - for 3-wire current output - for 3-wire voltage output Consumption Admissible variations Maximum line load
8...32 VDC (for RTD / linear input) or 12...36 VDC (for T/C input) 8...36 VDC (Umax+3)...36 VDC up to 2 mA (3-wire output) 1 Vp-p at 50 Hz 620 Ω (750 Ω for T/C) at 24V/20mA
Operating conditions -20...70 °C 0...95 %RH, non-condensing
Ambient temperature Ambient humidity
Design and materials Case material Wiring Mounting Dimensions [mm] Weight Protection class
in head (2,3,4) ø44x19 30 g IP20
plastic screw terminals on rail in box (3) 18x90x58 80x80x60 90 g 170 g IP20 IP65
(1)
Specify lower and upper span ranges when ordering. Head type "B" or any other with 33 mm distance between centers of the female threaded openings May be mounted on rail by a special snap-on accessory, which is ordered separately (see 'Accessories'). (4) May be mounted in different, separately ordered Ex housings for field applications (see 'Accessories'). (2)
Ordering code
TRN - G6'6".G11'11".G12
Code Feature or option G6'
G6"
(5)
Code values
Variant
2 - with 2-wire output line, 3 - with 3-wire output line
Input signal
Sensor
B - thermoresistance, C - thermocouple, D - linear RTD
B - Pt50, D - Pt100, F - Pt500, G - Pt1000, H - Cu50, K - Cu100, Z - other
T/C
J - "J", K - "K", E - "E", L - "L", T - "T", U - "U"
linear
A - 0…5 mA, B - 0…20 mA, C - 4…20 mA, H - 0…1 V, I - 0…2 V, J - 0…5 V, K - 0…10 V, Z - other
G11'
Output signal (5)
B - 0…5 mA, C - 1…5 mA, D - 2…10 mA, E - 0…20 mA, F - 4…20 mA, G - 0…1 V, H - 0…2 V, I - 0…5 V, J - 1…5 V, K - 0…10 V, L - 2…10 V, Z - other
G11"
Transmission range
(RANGE) (see table above)
G12
Mounting
B - in head (2,3), C - on DIN rail, D - in box IP65 (box included) (3), E - in Ex housing (includes mounting kit only)
For 2-wire output line, output signal can only be 4...20 mA (G11' = "F")!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(3)
transmitters Transmitter with Selectable Input TRA ♦ ♦ ♦ ♦ ♦ ♦ ♦
Low cost High resistance to electromagnetic disturbances Up to 10 selectable ranges for Pt100 sensors Up to 10 selectable thermocouples In-head and DIN-rail versions ATEX approved version IP65 box and Ex housing available
COMECO's temperature transmitter TRA is a compromising solution between the analog transmitters with fixed range and the programmable transmitters. TRA allows on-site selection of input range and sensor type (for thermocouples) as well as transmitter reaction to sensor failure by the means of a group of soldering bridges (jumpers). The exact range is adjustable by ZERO and SPAN potentiometers. TRA is available in case for mounting inside sensor protection head, in watertight box with high protection class, in case for mounting on a DIN rail, and in case prepared for mounting in Ex housings. An ATEX approved version is also available, and when used with external Zener barrier, all other transmitter versions are applicable for Ex zones. Thanks to its flexibility, excellent resistance against electromagnetic disturbances, and low price, TRA is easy to use and very widely applicable.
Technical specifications Input
Accuracy
Pt100 (w=1.385); 3-wire Thermocouple "E" Thermocouple "J" Thermocouple "K" Thermocouple "L" (2) Thermocouple "L - GOST" (2) Thermocouple "N" Thermocouple "R" (3) Thermocouple "S" (3) Thermocouple "T" Thermocouple "U" (3) Range selection Thermocouple selection ZERO adjustment SPAN adjustment
0…50/ 100/ 150/ 200/ 300/ 400/ 500 °C; -50…50/ 100 °C (1); 0…250 °C (1) 0...300/ 400/ 500/ 600 °C 0...400/ 500/ 600/ 800 °C 0...600/ 800/ 1000/ 1200 °C 0...700 °C 0...600 °C 0...800/ 1000/ 1200 °C 0...1200/ 1400/ 1600 °C 0...1200/ 1400/ 1600 °C 0...100/ 200/ 300 °C 0...100/ 200/ 300/ 400 °C with jumpers with jumpers ± 50 °C ± 10% ± 10%
Output Signal type RTD linearly proportional to T/C linearly proportional to Current limits Reaction at RTD failure: - for variant '1' - for variant '2' Reaction at T/C failure
4...20 mA temperature input voltage Low: < 3.5 mA, High: > 23 mA Low or High depends on terminal selectable High
Measurement error Non-linearity Self-heating error Temperature drift Cold junction compensation
0.3% from span 0.3% from span 0.02%/mA at 24 V 0.02% from span for 1 °C automatic hardware, ± 1 °C
Power supply Supply voltage Admissible variations Maximum line load: - for variant '1' - for variant '2'
8...32 VDC 1 Vp-p at 50 Hz 620 Ω (800 Ω for T/C) at 24V/20mA 700 Ω (800 Ω for T/C) at 24V/20mA
Operating conditions Ambient temperature: - for variant '1' - for variant '2' Ambient humidity
-20...70 °C -40...85 °C 0...95 %RH, non-condensing
Design and materials Case material Wiring Mounting Dimensions [mm] Weight Protection class
(4,5,6)
in head ø44x19 30 g IP20
plastic screw terminals (1) on rail in box (5) 18x90x58 80x80x60 90 g 170 g IP20 IP65
(1)
Available only for variant '1'. Ask for availability! Available only when in case for DIN-rail mounting (G12 = "C")! (4) Head type "B" or any other with 33 mm distance between centers of the female threaded openings (5) May be mounted on rail by a special snap-on accessory, which is ordered separately (see 'Accessories'). (6) May be mounted in different, separately ordered Ex housings for field applications (see 'Accessories'). (3)
Ordering code
TRA - G6.G12 - #1.#2
Code Feature or option
(7) (8)
Code values
Variant
1, 2
G6
Input
B - Pt100, C - thermocouple (7)
G12
Mounting
B - in head (4,5), C - on DIN rail (1), D - in box IP65 (box included) (5), E - in Ex housing (includes mounting kit only)
#1
Pre-set transmission range
X - none, (RANGE) (see table above)
#2
ATEX approval
X - none, EX - ATEX II 1G Ex ia IIB T4-T6 approved (8)
Thermocouple type is user selectable by jumpers. Available only for variant '2'.
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(2)
transmitters Programmable In-head RTD Transmitter TROJ ♦ ♦ ♦ ♦ ♦ ♦ ♦
For low-budget applications Pt100 input Programmable conversion range 2-wire 4…20 mA output Low profile Vibration-proof design Programming via free "TraCon" software
Technical specifications Input Input (RTD) type Measurement range Minimum programmable span
Output Signal type Maximum load Sensor failure reaction
(programmable) Pt100 (w=1.385) min. -50...max. 200 °C or min. -50...max. 600 °C 50 °C (programmable) 4...20 mA or 20...4 mA, 2-wire 800 Ω at 24V/20mA < 3.9 mA or > 20.2 mA, programmable
Accuracy Measurement error Self-heating error Non-linearity Temperature drift RTD 3-wire line compensation
0.2% from span or 0.2 °C (1) 0.005%/mA at 24 V within measurement error 0.01% from span for 1 °C up to 25 Ω per wire
Power supply 10...32 VDC 1 Vp-p at 50 Hz
Loop supply voltage Admissible variations
Interface Interface type Configuration software
RS232, requiring special cable (2) "TraCon", free
Operating conditions Ambient temperature Ambient humidity
-20...70 °C 0...95 %RH, non-condensing
Design and materials Case material Wiring Mounting Interface connector Interface cable type (2) Dimensions [mm] Weight Protection class
in head (3,4,5) 4-pin K1, K11U ø44x19 25 g IP20
plastic screw terminals in box (4) 4-pin K1, K11U 80x80x60 170 g IP65
(1)
Which is greater Ordered separately (3) Head type "B" or any other with 33 mm distance between centers of the female threaded openings (4) May be mounted on rail by a special snap-on accessory, which is ordered separately (see 'Accessories'). (5) May be mounted in different, separately ordered Ex housings for field applications (see 'Accessories'). (2)
Ordering code
TROJ - G12
Code Feature or option
1 - for min. -50...max. 200 °C, 2 - for min. -50...max. 600 °C
Mounting
B - in head (3,4), D - in box IP65 (box included) (4), E - in Ex housing (includes mounting kit only)
COMECO reserves the right of changing specifications without prior notice!
G12
Code values
Variant
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
transmitters Low-cost Programmable Transmitter TRC ♦ ♦ ♦ ♦ ♦ ♦
Smallest in-head programmable transmitter Pt100 and 8 T/C programmable ranges 2- or 3-wire current and voltage output Serial interface for configuration In-head and DIN-rail versions IP65 box and Ex housing available
COMECO's temperature transmitter TRC is part of a revolutionary new project for the smallest (in-head) and cheapest multi-input programmable transmitter. It has a universal input accepting Pt100 RTD and 8 thermocouples and a voltage or current 2- or 3-wire output linearly proportional to the measured temperature. This model allows on-site selection of sensor type, input range and conversion direction as well as sensor failure reaction and no user calibration is necessary to be provided. TRC is available in a case for mounting inside sensor protection head, in a watertight box with high protection class, and in a case for mounting on DIN rail. The serial interface allows fast and easy configuration. Thanks to the combination of performance, reliability, simplicity, flexibility, and low price, the TRC transmitter is easy to use and very widely applicable.
Technical specifications Input
(programmable) min. -200…max. 600 °C min. 200...max. 1800 °C min. -20...max. 600 °C min. -20...max. 900 °C min. -20...max. 1200 °C min. -20...max. 1200 °C min. 0...max. 1700 °C min. 0...max. 1700 °C min. -40...max. 400 °C direct or reverse, programmable
Pt100 (w=1.385); 3-wire Thermocouple "B" Thermocouple "E" Thermocouple "J" Thermocouple "K" Thermocouple "N" Thermocouple "R" Thermocouple "S" Thermocouple "T" Input / output conversion
Output
'2'
Voltage - minimum load Current - maximum load Sensor failure reaction
'3'
0...10 V 1 MΩ 0(4)...20 mA 4...20 mA 750 Ω at 24V/20mA 800 Ω at 24V/20mA < 3.9 mA or > 20.2 mA, downscale or upscale, programmable programmable
Power supply Supply voltage Admissible variations
8...36 VDC 1 Vp-p at 50 Hz
9...36 VDC (1) 1 Vp-p at 50 Hz
Accuracy 0.3% from span within measurement error 0.005%/mA at 24 V 0.01% from span for 1 °C automatic software, ± 0.5 °C up to 25 Ω per wire
Measurement error Non-linearity Self-heating error Temperature drift Cold junction compensation RTD 3-wire line compensation
Interface RS232, requiring special cable (2) "TraCon", free
Interface type Configuration software
Operating conditions -20...70 °C 0...95 %RH, non-condensing
Ambient temperature Ambient humidity
Design and materials Case material Wiring Mounting Interface connector Interface cable type (2) Dimensions [mm] Weight Protection class
in head (3,4,5) 4-pin K1, K11U ø44x19 30 g IP20
plastic screw terminals in box (4) on rail 3-pin 4-pin K2, K12U K1, K11U 18x90x58 80x80x60 90 g 170 g IP20 IP65
(1)
13...36 VDC for output 0...10 V Ordered separately Head type "B" or any other with 33 mm distance between centers of the female threaded openings (4) May be mounted on rail by a special snap-on accessory, which is ordered separately (see 'Accessories'). (5) May be mounted in different, separately ordered Ex housings for field applications (see 'Accessories'). (2) (3)
Code Feature or option G11 G12 (6)
Variant
Code values 2 - with 2-wire output line, 3 - with 3-wire output line
Output signal (6)
E - 0…20 mA, F - 4…20 mA, K - 0…10 V, Z - other
Mounting
B - in head (3,4), C - on DIN rail, D - in box IP65 (box included) (4), E - in Ex housing (includes mounting kit only)
For 2-wire output variant only 4...20 mA is available!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code TRC - G11.G12
transmitters Low-cost SMART Transmitter TRB ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
Universal programmable input User-selectable 4 RTD types and 6 thermocouples Accepts linear current, voltage, and resistive signals Programmable input and output range Built-in programmable digital filter Manual output control Serial interface for programming IP65 box and Ex housing available
The intelligent non-isolated transmitter TRB, manufactured by COMECO, is available in case prepared for mounting in Ex housings, in casing for in-head mounting, and in another for DIN-rail mounting, as well as mounted into an IP65 protection box. This transmitter allows the user to: - select sensor and input signal type; - select and adjust input range; - perform offset correction and device calibration; - specify input ranges and output type (4…20 mA / 20…4 mA); - select decimal point position and measurement unit; - select output reaction at sensor failure; - adjust the digital filter. The TRB transmitter is easy to program via the specialized configuration software "TraCon". Thanks to its large capabilities and low price, TRB can be very useful in various industrial applications requiring temperature conversion before following measurement and control.
Technical specifications Pt100 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire PTC (1k at 25 °C); 3-wire PTC (2k at 25 °C); 3-wire RTD minimum range width Thermocouple "T" Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" T/C minimum range width Linear current Linear voltage Linear resistive Custom linear (option) Offset adjustment Digital low-pass filter Digital peak filter
Input monitoring Sensor failure reaction
(programmable) min. -100...max. 850 °C min. -100...max. 600 °C min. -50...max. 150 °C min. -50...max. 150 °C 50 °C min. -40...max. 400 °C min. -20...max. 1000 °C min. -20...max. 1300 °C min. 0...max. 1700 °C min. 0...max. 1700 °C min. 200...max. 1800 °C 100 °C 0(4)...20 mA 0...100 mV or 0...10 V (1) 0...1 kΩ on request (2) within range limits programmable programmable (programmable) < 3.8 mA or > 20.2 mA, programmable
Output
(programmable) 4...20 mA or 20...4 mA measured value 4 μA through interface 0...100%, programmable
Signal type Linearly proportional to Resolution Output calibration Manual output control
Accuracy Measurement error Non-linearity Temperature drift Cold junction compensation
0.3% from span within measurement error 0.01% from span for 1 °C automatic software, ± 0.5 °C
Power supply 8...32 VDC ± 10% 750 Ω at 24V/20mA
Supply voltage Maximum line load
Interface RS232, requiring special cable (3) "TraCon", free
Interface type Configuration software
Operating conditions -20...70 °C 0...95 %RH, non-condensing
Ambient temperature Ambient humidity
Design and materials Case material Wiring Mounting Interface connector Interface cable type (3) Dimensions [mm] Weight Protection class
in head (4,5,6) 4-pin K1, K1U, K11U ø44x23 40 g IP20
(1)
Ask for availability! Instead of linear current (3) Ordered separately (4) Head type "B" or any other with 33 mm distance between centers of the female threaded openings (5) May be mounted on rail by a special snap-on accessory, which is ordered separately (see 'Accessories'). (6) May be mounted in different, separately ordered Ex housings for field applications (see 'Accessories'). (2)
Ordering code
TRB - G12 - #1
Code Feature or option
Code values
G12
Mounting
B - in head (4,5), C - on DIN rail, D - in box IP65 (box included) (5), E - in Ex housing (includes mounting kit only)
#1
Auxiliary input signal
X - none, Z - linear signal (specify!) (2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
plastic screw terminals in box (5) on rail 3-pin 4-pin K2, K1, K2U, K12U K1U, K11U 18x90x58 80x80x60 60 g 180 g IP20 IP65
COMECO reserves the right of changing specifications without prior notice!
Input
transmitters Isolated SMART Transmitter TRBI ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
1500 VAC input / output isolation Universal programmable input User-selectable 4 RTD types and 6 thermocouples Accepts linear current, voltage, and resistive signals Programmable input and output range Built-in programmable digital filter Manual output control Serial interface for programming IP65 box and Ex housing available
The intelligent isolated transmitter TRBI, manufactured by COMECO, is available in case prepared for mounting in Ex housings, in casing for in-head mounting, and in another for DIN-rail mounting, as well as mounted into an IP65 protection box. This transmitter allows the user to: - select sensor and input signal type; - select and adjust input range; - perform offset correction and device calibration; - specify input ranges and output type (4…20 mA / 20…4 mA); - select decimal point position and measurement unit; - select output reaction at sensor failure; - adjust the digital filter. The TRBI transmitter is easy to program via the specialized configuration software "TraCon". Thanks to its large capabilities and low price, TRBI can be very useful in various industrial field applications requiring signal isolation.
Technical specifications Pt100 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire PTC (1k at 25 °C); 3-wire PTC (2k at 25 °C); 3-wire RTD minimum range width Thermocouple "T" Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" T/C minimum range width Linear current Linear voltage Linear resistive Custom linear (option) Offset adjustment Digital low-pass filter Digital peak filter Input / output isolation
Input monitoring Sensor failure reaction
(programmable) min. -100...max. 850 °C min. -100...max. 600 °C min. -50...max. 150 °C min. -50...max. 150 °C 50 °C min. -40...max. 400 °C min. -20...max. 1000 °C min. -20...max. 1300 °C min. 0...max. 1700 °C min. 0...max. 1700 °C min. 200...max. 1800 °C 100 °C 0(4)...20 mA 0...100 mV or 0...10 V (1) 0...1 kΩ on request (2) within range limits programmable programmable 1500 VAC for 1 min (programmable) < 3.8 mA or > 20.2 mA, programmable
Output
(programmable) 4...20 mA or 20...4 mA measured value 4 μA through interface 0...100%, programmable
Signal type Linearly proportional to Resolution Output calibration Manual output control
Accuracy Measurement error Non-linearity Temperature drift Cold junction compensation
0.3% from span within measurement error 0.01% from span for 1 °C automatic software, ± 0.5 °C
Power supply 8...32 VDC ± 10% 750 Ω at 24V/20mA
Supply voltage Maximum line load
Interface RS232, requiring special cable (3) "TraCon", free
Interface type Configuration software
Operating conditions -20...70 °C 0...95 %RH, non-condensing
Ambient temperature Ambient humidity
Design and materials Case material Wiring Mounting Interface connector Interface cable type (3) Dimensions [mm] Weight Protection class
in head (4,5,6) 4-pin K1, K1U, K11U ø44x23 40 g IP20
(1)
Ask for availability! Instead of linear current Ordered separately (4) Head type "B" or any other with 33 mm distance between centers of the female threaded openings (5) May be mounted on rail by a special snap-on accessory, which is ordered separately (see 'Accessories'). (6) May be mounted in different, separately ordered Ex housings for field applications (see 'Accessories'). (2) (3)
Ordering code
TRBI - G12 - #1
Code Feature or option
Code values
G12
Mounting
B - in head (4,5), C - on DIN rail, D - in box IP65 (box included) (5), E - in Ex housing (includes mounting kit only)
#1
Auxiliary input signal
X - none, Z - linear signal (specify!) (2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
plastic screw terminals in box (5) on rail 3-pin 4-pin K2, K1, K2U, K12U K1U, K11U 18x90x58 80x80x60 60 g 180 g IP20 IP65
COMECO reserves the right of changing specifications without prior notice!
Input
transmitters HART Programmable Transmitter TRH ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
2000 VAC input / output isolation Universal programmable input User-selectable 8 RTD types and 8 thermocouples Accepts various linear voltage and resistive signals Programmable input and output features Built-in digital filter Manual output control Programming via HART protocol Free configuration software Intrinsically safe version
The intelligent isolated transmitter TRH is a programmable 2-wire HART device with 2000 V input/output isolation level. It is available in case prepared for mounting in 33 mm sensor heads, plastic protection box, and different Ex housings. The transmitter allows the user to program various input and output features including input signal type and range, output offset and calibration, reaction at sensor failure, fixed output current, digital filter, etc. TRH can be ordered with intrinsically safe option for Ex applications. The transmitter is easy to program via HART modem over the current loop using free configuration software "HartTemp". Thanks to its large capabilities and low price, TRH can be very useful in various industrial field applications requiring signal isolation and HART communication.
Technical specifications Pt100; 3(4)-wire Pt500 (Pt1000); 3(4)-wire (5) Cu50 (Cu100); 3(4)-wire Ni100; 3(4)-wire Ni500 (Ni1000); 3(4)-wire (5) RTD minimum range width Thermocouple "T" Thermocouple "E" Thermocouple "J" Thermocouple "K" Thermocouple "N" Thermocouple "S"("R") Thermocouple "B" T/C minimum range width Linear voltage [mV] Linear voltage [V] Minimum range [mV] Linear resistive Minimum range [Ω] Input / output isolation
Output Output range Linearly proportional to Resolution Response time Switch-on delay Digital filter Output calibration Output manual control Sensor failure reaction (1) (2) (3)
Measurement error - Pt500, Ni500 - Pt1000, Ni1000, Cu100, 0...2 kΩ - other input types Non-linearity Temperature drift Load and power supply influence Long-term stability Cold junction compensation Supply voltage Maximum line load
Communication Configuration software
HART protocol over current loop "HartTemp", free
Operating conditions Ambient temperature Ambient humidity Shocks and vibrations
-40...85 °C 0...90 %RH 4g, 2...150 Hz, according to EN 60068
Design and materials Case material Wiring Mounting Dimensions Weight Protection class Intrinsic safety
Code values
Mounting
B - in head (1,2), D - in box IP65 (box included) (2), E - in Ex housing (includes mounting kit only) (4)
#1
Intrinsic safety
X - none (5), E - Ex ia IIC T4 certified
#2
Customized input and/or range
X - none, Z - custom input signal/range (specify!) (5)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
7.5...45 VDC 750 Ω at 24V/20mA
Interface
G12
Does not include housing! Contact COMECO
0.2 % from span 0.12 % from span 0.08 % from span within measurement error negligible negligible ≤ 0.05% from span per 1 year internal, automatic
Power supply
TRH - G12 - #1.#2
Code Feature or option
(5)
Accuracy
Head type "B" or any other with 33 mm distance between centers of the female threaded openings May be mounted on rail by a special snap-on accessory, which is ordered separately (see 'Accessories'). May be mounted in different, separately ordered Ex housings for field applications (see 'Accessories').
Ordering code
(4)
(programmable) min. -200...max. 850 °C min. -200...max. 250 °C min. -50...max. 150 °C min. -60...max. 180 °C min. -60...max. 180 (150) °C 10 °C min. -270...max. 400 °C min. -270...max. 1000 °C min. -210...max. 1200 °C min. -270...max. 1372 °C min. -270...max. 1300 °C min. -50...max. 1768 °C min. 0...max. 1820 °C 50 °C (500 °C for noble T/C) -10...75 mV, -100...100 mV (5) -0.5...0.5 V (5), -1...2 V (5) 5 mV (20 mV for 2 V range) min. 0...max. 400(2000) Ω 10 Ω (20 Ω for 2 k range) 2000 VAC for 1 min (programmable) 4...20 mA, 2-wire measured value 0.3 μA 1s ≤5s programmable configuration software 0...100% via configuration software ≤ 3.8 mA, ≥ 20.5 mA
PC plastic with epoxy potting screw terminals in box (2) in head (1,2,3) 80x80x60 mm ø44x24 mm approx. 34 g approx. 170 g IP65 IP00 Ex ia IIC T4 Ex ia IIC T4
COMECO reserves the right of changing specifications without prior notice!
Input
transmitters Universal Isolated SMART Transmitter TRZ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
11-pin relay socket for fast rail mounting 1500 VAC input / output / supply isolation Programmable input Programmable output Internally generated sensor supply Built-in programmable digital filter Manual output control Serial interface for programming
The intelligent isolated transmitter TRZ can be a proper solution when different signal conversions are needed. This transmitter allows the user to: - select sensor and input signal type (RTD, T/C, mA, mV, V, R); - select and adjust input range; - select output type (0(4)...20 mA or 0...10 V); - control the output manually; - perform offset correction and device calibration; - specify the input-to-output correspondence (direct or reverse); - select decimal point position and measurement unit; - select output reaction at sensor failure; - adjust the digital filter. The TRZ transmitter is easy to program via the specialized configuration software "TraCon". Thanks to its convenient 11-pin connector case, TRZ can be easily fit in a standard UNDECAL socket and mounted on DIN rail.
Technical specifications (programmable) min. -200...max. 850 °C min. -100...max. 600 °C min. -50...max. 150 °C min. -50...max. 150 °C 50 °C min. -40...max. 400 °C min. -20...max. 1000 °C min. -20...max. 1300 °C min. 0...max. 1700 °C min. 0...max. 1700 °C min. 200...max. 1800 °C 100 °C 0(4)...20 mA 0...100 mV, 0…10 V 0...1 kΩ on request (1) within range limits programmable programmable 1500 VAC for 1 min
Pt100 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire PTC (1k at 25 °C); 3-wire PTC (2k at 25 °C); 3-wire RTD minimum range width Thermocouple "T" Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" T/C minimum range width Linear current Linear voltage Linear resistive Custom linear (option) Offset adjustment Digital low-pass filter Digital peak filter Input / output isolation
Input monitoring
(programmable) 0 mA or > 20.2 mA, programmable
Sensor failure reaction
Output
(programmable) 0(4)...20 mA or 20...0(4) mA max. 600 Ω at 20 mA 0...10 V or 10...0 V min. 2 kΩ at 10 V measured value 4 μA / 2.5 mV through interface 0...100%, programmable 18…28 VDC, max. 30 mA
Current - load Voltage - load Linearly proportional to Resolution Output calibration Manual output control Excitation voltage (1) (2)
Accuracy Measurement error Non-linearity Temperature drift Cold junction compensation
Power supply Mains supply voltage Isolated low voltage Consumption
'Power' LED 'Load' LED 'Alarm' LED
Interface type Configuration software
RS232, requiring special cable (2) "TraCon", free
Operating conditions Ambient temperature Ambient humidity
-20...70 °C 0...95 %RH, non-condensing
Design and materials Case material Mounting Wiring Interface connector Interface cable type (2) Dimensions Weight Protection class
Code values
G1
Power supply
A - 230 VAC, B - 115 VAC, Q - 12…24 V, isolated, R - 24 VAC
#1
Auxiliary input signal
X - none, Z - linear signal (specify!) (1)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
for power supply ON for voltage output overload for broken current output loop
Interface
TRZ - G1 - #1
Code Feature or option
230 VAC or 115 VAC ± 10% 12…24 V or 24 VAC max. 1.5 VA
Indication
Instead of linear current or voltage 0...10 V Ordered separately (see 'Accessories')
Ordering code
0.3% from span within measurement error 0.01% from span for 1 °C automatic software, ± 0.5 °C
plastic in socket or on 35 mm DIN rail socket UNDECAL (2) 3-pin K2 (RS232) or K12U (USB) 35x78x91 mm 180 g IP20
COMECO reserves the right of changing specifications without prior notice!
Input
transmitters Infrared Temperature Transmitter TRU ♦ ♦ ♦ ♦ ♦ ♦ ♦
Low-temperature remote measurement Object temperature range from -10 to 150 °C Field of view 7.3 ° Linear current or voltage output signal Serial interface available Local programmable indicator available IP66 protection class
The TRU temperature transmitter's operation is based on the principle of sensing infrared radiation, emitted from a heated object, situated at a certain distance from the sensor, at a 7.3 ° conical angle. The sensitive thermopile element comprises of a multitude of thermocouples connected in series and allows measurement of the object surface temperature within the -10…150 °C range. The incorporated electronics converts the sensor output into a standard current or voltage signal suitable for further transmission and processing. Moreover, the transmitter may be equipped with programmable local LED indicator as well as with RS232 serial interface for data transmitting. By the means of specialized software, the information about the object's temperature may be viewed, stored, and printed from a PC. TRU is enclosed in a robust plastic box with connector, both with IP66, and is designed to be either freely mounted or mounted on DIN rail via special brackets. The TRU transmitter is very suitable for these special applications that require non-contact low-temperature-object measurement.
Technical specifications Input
Interface
Input type Material emission coefficient Object temperature range Calibrating distance Calibrating spot Field of view
object infrared emission 5...15 μm ≥ 0.85 min. -10...max. 150 °C 5 cm 3.5 cm 7.3 °
Analog output Output signal Output function Accuracy Temperature drift Maximum output load Output overload reaction
0(4)...20 mA or 0...10 V input signal info retransmission 2% from span 0.02% from span for 1 °C 750 Ω at 24V/20 mA display message
Local indicator (option) 3 LED indicators, 14 mm 1 °C 2 membrane keys
Digital display Display resolution Keyboard
Power supply Supply voltage Admissible variations Consumption
15...32 VDC 4 Vp-p at 50 Hz max. 120 mA
Operating conditions Ambient temperature Storage temperature
-10...65 °C -20...85 °C
Design and materials Case material Mounting Wiring Dimensions Weight Protection class
ABS/PC plastic free (1) 4-pin М12 connector 80x92x65 mm max. 250 g IP66
Radial, axial, and DIN-rail mounting accessories for 80x80x60 mm box can be ordered separately (see 'Accessories').
Ordering code
TRU - G9.G11 - #1
Code Feature or option
(2)
RS232 data transmission
Code values
G9
Serial interface
X - none, A - RS232
G11
Analog output
X - none (2), E - 0…20 mA, F - 4…20 mA, K - 0…10 V, Z - other on request
#1
Local indicator (2)
X - none, A - local indicator mounted
When no output is requested, local indicator must be ordered!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(1)
Interface type Function
transmitters RS485 SMART DIN-Rail Transmitter TRIS ♦ ♦ ♦ ♦ ♦ ♦ ♦
Low-cost network transmitter - up to 32 devices Universal programmable input User-selectable 4 RTD types and 6 thermocouples Accepts linear current and voltage signals Built-in programmable digital filter Convenient programming through RS485 Input / output / supply isolation
TRIS is an intelligent rail-mountable transmitter with universal input and RS485 output, specially designed for multi-point process measurement and data acquisition in a network with up to 32 devices. This transmitter allows the user to: - select sensor and input signal type (4 RTD types, 6 thermocouples, and 4 linear signals); - select and adjust input range; - perform offset correction and device calibration; - select decimal point position and measurement unit; - adjust the digital filter. A network of up to 32 transmitters can be configured and monitored by using the universal COMECO data-acquisition program "PolyMonitor". Thanks to its isolated universal input, networking capabilities, and low price, TRIS is particularly suitable for multi-point data acquisition applications.
Technical specifications Input Pt100 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire PTC (1k at 25 °C); 3-wire PTC (2k at 25 °C); 3-wire RTD minimum range width Thermocouple "T" Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" T/C minimum range width Linear current Linear voltage Custom linear (option) Offset adjustment Digital low-pass filter Digital peak filter Isolation
(programmable) min. -100...max. 850 °C min. -100...max. 600 °C min. -50...max. 150 °C min. -50...max. 150 °C 50 °C min. -40...max. 400 °C min. -20...max. 1000 °C min. -20...max. 1300 °C min. 0...max. 1700 °C min. 0...max. 1700 °C min. 200...max. 1800 °C 100 °C 0(4)...20 mA 0...100 mV or 0…10 V on request (1) within range limits programmable programmable > 1000 VAC for 1 min
(2)
Configuration software Monitoring and data acquisition software
Accuracy Measurement error Non-linearity Temperature drift Cold junction compensation Supply voltage Consumption
Protocol
12…24 V max. 100 mA
Indication 'ON' LED 'SEL' LED
for power supply ON for active communication
Operating conditions Ambient temperature Ambient humidity Case material Wiring Mounting Dimensions Weight Protection class
TRIS - G9
Code Feature or option G9
0.3% from span within measurement error 0.01% from span for 1 °C automatic software, ± 0.5 °C
Power supply
Instead of linear current Ordered separately
Ordering code
"UniConf", free "PolyMonitor"
-20...70 °C 0...95 %RH, non-condensing
Design and materials RS485 configuration and networking up to 32 8 (data) + 1 (stop), even parity 1200 / 2400 / 4800 / 9600 bps 2500 VAC for 1 min
Interface type Function Network devices Format Baud rate Isolation (1)
(2)
Code values A - ASCII, C - ASCII for "PolyMonitor"
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
plastic plug-in terminals on 35 mm DIN rail 35x110x58 mm 90 g IP20
COMECO reserves the right of changing specifications without prior notice!
Output / Interface
Software
electrochemical control equipment
pH/ORP Preamplifier PHA ♦ ♦ ♦ ♦ ♦ ♦ ♦
Low cost 13 High input impedance – over 10 Ω Low output impedance Temperature compensation available Unipolar or bipolar supply voltage High IP protection class available May be connected to low-cost measurement devices
COMECO’s PHA preamplifier amplifies the voltage from pH or REDOX potential (ORP) probes through a special amplifier that serves as input buffer and provides the high input impedance necessary for normal operation of pH/ORP probes. The low impedance output of the preamplifier may be connected to a standard indicator, data logger, or controller. Two PHA variants are available: - variant '100' with low IP protection class that needs bipolar supply voltage; - variant '150' with high IP protection class and single polarity supply voltage. PHA100 serves only as a high input impedance buffer; no change of voltage signal is performed. PHA150 shifts input signal so that the output voltage has single polarity (its polarity does not change), and allows temperature compensation measurement via an additional Pt100 input. Variant '150' is designed for wall mounting, while PHA100 is to be either left to hang freely on its wires or mounted by the means of a bracket. Both variants are applicable in cases in which there is a need to connect pH/ORP probes to measurement devices without posing special requirements to devices' input circuits and connection cables. The fields of application include biotechnological, chemical, food, and other industries, and research.
Technical specifications Input
Accuracy
Input range: - pH - ORP Temperature compensation input Input impedance Input capacitance
Error Temperature drift
Output
0...14 pH -2000...+2000 mV external Pt100, 0...100 °C > 1013 Ω 0.5 pF
(1)
'100'
'150'
+410...-410 mV -2000...+2000 mV ± 1 mV 1 kΩ
+2910...1090 mV 500...+4500 mV 1 kΩ
± 5...± 8 VDC ± 1% max. 0.1 mA
5...9 VDC ± 5% max. 2 mA
Power supply Supply voltage Admissible variations Consumption
0...60 °C 10...85 %RH -10...70 °C 0...95 %RH
0...70 °C 0...95 %RH (2) -10...70 °C 0...95 %RH
Case material Mounting Wiring Dimensions Weight Protection class Increased IP (option)
aluminum free exposed terminals ø25x60 mm 30 g IP20 -
aluminum on wall hidden terminals 46x80x32 mm 120 g IP20 IP65
Not available for variant '100'! With increased protection
Ordering code
PHA - G6 - #1
Code Feature or option G6 #1 (3)
Operating temperature Operating humidity Storage temperature Storage humidity
Variant
100 - bipolar, 150 - unipolar
Input Increased protection
Code values DN - pH, DO - ORP
(3)
X - none, P - IP65 protection
ONLY for variant '150'
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(1)
Operating conditions
Design and materials
Output signal (at 25 °C): - pH - ORP Output asymmetry Output impedance
(2)
'100' '150' < ± 0.01% from span < ± 0.05% from span 2 μV / °C 3 μV/ °C
electrochemical control equipment
pH/ORP Preamplifier PHA ♦ ♦ ♦ ♦ ♦ ♦ ♦
Low cost 13 High input impedance – over 10 Ω Low output impedance Temperature compensation available Unipolar or bipolar supply voltage High IP protection class available May be connected to low-cost measurement devices
COMECO’s PHA preamplifier amplifies the voltage from pH or REDOX potential (ORP) probes through a special amplifier that serves as input buffer and provides the high input impedance necessary for normal operation of pH/ORP probes. The low impedance output of the preamplifier may be connected to a standard indicator, data logger, or controller. Two PHA variants are available: - variant '100' with low IP protection class that needs bipolar supply voltage; - variant '150' with high IP protection class and single polarity supply voltage. PHA100 serves only as a high input impedance buffer; no change of voltage signal is performed. PHA150 shifts input signal so that the output voltage has single polarity (its polarity does not change), and allows temperature compensation measurement via an additional Pt100 input. Variant '150' is designed for wall mounting, while PHA100 is to be either left to hang freely on its wires or mounted by the means of a bracket. Both variants are applicable in cases in which there is a need to connect pH/ORP probes to measurement devices without posing special requirements to devices' input circuits and connection cables. The fields of application include biotechnological, chemical, food, and other industries, and research.
Technical specifications Input
Accuracy
Input range: - pH - ORP Temperature compensation input Input impedance Input capacitance
Error Temperature drift
Output
0...14 pH -2000...+2000 mV external Pt100, 0...100 °C > 1013 Ω 0.5 pF
(1)
'100'
'150'
+410...-410 mV -2000...+2000 mV ± 1 mV 1 kΩ
+2910...1090 mV 500...+4500 mV 1 kΩ
± 5...± 8 VDC ± 1% max. 0.1 mA
5...9 VDC ± 5% max. 2 mA
Power supply Supply voltage Admissible variations Consumption
0...60 °C 10...85 %RH -10...70 °C 0...95 %RH
0...70 °C 0...95 %RH (2) -10...70 °C 0...95 %RH
Case material Mounting Wiring Dimensions Weight Protection class Increased IP (option)
aluminum free exposed terminals ø25x60 mm 30 g IP20 -
aluminum on wall hidden terminals 46x80x32 mm 120 g IP20 IP65
Not available for variant '100'! With increased protection
Ordering code
PHA - G6 - #1
Code Feature or option G6 #1 (3)
Operating temperature Operating humidity Storage temperature Storage humidity
Variant
100 - bipolar, 150 - unipolar
Input Increased protection
Code values DN - pH, DO - ORP
(3)
X - none, P - IP65 protection
ONLY for variant '150'
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(1)
Operating conditions
Design and materials
Output signal (at 25 °C): - pH - ORP Output asymmetry Output impedance
(2)
'100' '150' < ± 0.01% from span < ± 0.05% from span 2 μV / °C 3 μV/ °C
electrochemical control equipment pH/ORP Transmitter PHT ♦ ♦ ♦ ♦ ♦
Low cost 4 design variants 13 High input impedance – over 10 Ω Standard current or voltage output signal Automatic temperature compensation
The PHT transmitter converts the high impedance voltage output of pH or REDOX (ORP) probes into standard current or voltage signal that can be safely sent over longer distances. The transmitter provides the necessary for the normal pH/ORP probe's operation high input impedance as well as temperature compensation of pH measurement through a Pt100 or Pt1000 temperature sensor connected to the second transmitter input. Four variants are available differing by power supply, output signal, type of mounting, and protection class. The PHT transmitter is applicable in all cases in which there is a need for measuring pH or ORP and the measurement signal has to be sent over relatively long distance from the point of measurement.
Technical specifications Inputs
Accuracy
pH/ORP input
Measurement error Temperature drift
0...14 pH, 2...12 pH, -1...+1 V, -2...+2 V > 1013 Ω 0.5 pF external Pt100 or Pt1000, 0...100 °C
Input impedance Input capacitance Temperature compensation input
Variant
< ± 0.2% from span 0.005% from span for 1 °C
Operating conditions Ambient temperature Ambient humidity Storage temperature Storage humidity
0...60 °C 10...85 %RH -10...70 °C 0...95 %RH
10
30
50
100
2-wire 4…20 mA
2-wire 4…20 mA
2-wire 4…20 mA
0(4)…20 mA, 0…2 V, or on request
8…30 VDC (1)
8…30 VDC (1)
8…30 VDC (1)
230 VAC
IP20
IP44 (except BNC connector)
IP65 (except BNC connector)
IP56 (except BNC connector)
Output Power supply Protection
plastic
plastic
aluminum
plastic
ø43x30 mm
90x90x40 mm
46x80x32 mm
108x108x60 mm
Housing Dimensions
30 g
120 g
150 g
280 g
in head type "B" (2)
on wall (2) hidden screw terminals or BNC connector
on wall hidden screw terminals or BNC connector
on wall hidden screw terminals or BNC connector
Weight Mounting Probe connection (1) (2)
exposed screw terminals
12…32 VDC with ORP input May be mounted on rail by a special snap-on accessory, which is ordered separately (see 'Accessories')
Ordering code
PHT - G6'6"G6'6".G11'11".G12
Code Feature or option
10 - tablet, 30 - in IP44 plastic box, 50 - with IP65 metal enclosure, 100 - for mains power supply
G6'6"
Input
G11'
Output signal (3)
G11"
Transmission range
G12
Code values
Variant
Probe connection
pH/ORP
DN - pH, DO - ORP
temperature
BD - Pt100, BG - Pt1000 E - 0…20 mA, F - 4…20 mA, H - 0…2 V, Z - other (specify!)
(4)
(RANGE) (see table above) X - screw terminals, B - BNC connector
(3)
Applicable for the selected variant (4) Do not code for variant '10'
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Specifications
electrochemical control equipment Conductivity Transmitter / Controller PHC20 ♦ ♦ ♦ ♦ ♦ ♦ ♦
DIN-rail mounting Operates with 2-electrode contacting cells 0.1...100000 µS measurement range Relay alarm / control output Analog retransmission output Pt1000 temperature compensation Fully programmable
PHC20 is a reliable conductivity transmitter, enclosed in a small housing for DIN-rail mounting, especially designed for clear, industrial, and sea water applications. It is compatible with COMECO's conductivity probes series CSK as well as other 2-electrode contacting conductivity cells within conductance range from 0.1 µS to 100 mS, and has an additional Pt1000 input for automatic temperature compensation. The transmitter provides linear current or voltage output and can also be equipped with a relay alarm/control output. All device parameters (preset conductance ranges, analog output range and direction, relay set point, hysteresis, and direction, temperature compensation parameters, etc.) are user-programmable via the RS232 interface and supplied free configuration software. Thanks to its wide measurement range, flexibility, programmability, and reliability, the PHC20 transmitter is very suitable for water treatment and processing applications in the food, pharmaceutical, and many other industries.
Technical specifications Input
Interface
Input type Measurement range Selectable ranges Temperature input Temperature compensation
2-electrode contacting cell 0.1 µS to 100 mS 0.1...10 µS, 10...1000 µS, 1...100 mS Pt1000 0.0...10.0 %/°C, selectable TDS
Accuracy Total measurement error Temperature drift
± 2% from span (incl. non-linearity) 0.06% from span for 1 °C
Analog output 0(4)...20 mA, 0...10 V, reversible 0.025% max. 750 Ω at 20 mA max. 2 kΩ at 10 V 1500 VAC for 1 min
Relay output MOS gate Output function Set point Isolation from input
Power supply 24 VDC ± 10% 4 Vp-p at 50 Hz max. 60 mA 1500 VAC for 1 min
Supply voltage Admissible variations Consumption Isolation from input
0.1A/60V, optically isolated ON/OFF, alarms configurable via interface 1500 VAC for 1 min
Ambient temperature Operating humidity Storage temperature
-10...65 °C 0...85 %RH, non-condensing -20...85 °C
Design and materials Case material Mounting Wiring Dimensions Weight Protection class
plastic on 35 mm DIN rail screw terminals 23x90x58 mm max. 100 g IP20
Ordered separately (see 'Accessories')
PHC20 - G5.G11
Code Feature or option
Code values
G5
Relay output
X - none (2), M - isolated MOS gate, Z - other (specify!)
G11
Analog output
X - none (2), E - 0…20 mA, F - 4…20 mA, K - 0…10 V, Z - other (specify!)
At least one output must be ordered!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
(2)
RS232, requiring special cable (1) free K2, K2U, K12U
Operating conditions
Output signal Resolution Current load Voltage load Isolation from input
(1)
Interface type Configuration software Interface cable type (1)
electrochemical control equipment Carbon-Dioxide Transmitter PHG ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
Low cost Dual NDIR sensor built-in For HVAC and food processing applications Good accuracy, sensitivity and selectivity Low humidity and temperature dependence Duct mounting variant Local indicator available RS232 interface option
PHG transmitter measures CO2 concentration in in-door atmospheres and converts it into standard current or voltage signal. PHG model uses dual nondispersive infrared (NDIR) carbon-dioxide sensor providing improved accuracy and sensitivity as well as low temperature and humidity dependence. The transmitter can be equipped with local 4-digit LED display and RS232 serial interface. PHG mounting variants include free or duct installation with top or bottom mounted connector. PHG application area includes indoor air control, ventilation, air-conditioning, mushroom control, etc.
Technical specifications Input
Local indicator
Input type Measurement range
Non-dispersive Infrared CO2 cell 0...3000/5000/10000 ppm
Accuracy (1)
Measurement error Temperature dependence Warm-up time Response time (0…80%)
± 2 ppm (0…3000 ppm) at 10…50 °C 10 ppm for 1 °C max. 90 s (at 25 °C) max. 30 s (w/o sintered filter)
Output 0(4)...20 mA 2s 350 Ω at 20 mA 35 ± 2 mA
Output signal Output update Minimum output load Maximum output load Over-scale limit
0…10 V 2s 1 MΩ 17 ± 2 V
Interface Interface type Function Protocol
RS232, 9600 bps CO2 data transmission ASCII, free
Power supply Supply voltage Admissible variations Consumption
15...32 VDC 1 Vp-p at 50 Hz max. 90 mA (150 mA w/ indicator)
Digital display Display resolution Display refresh Accuracy Temperature drift
4 LED indicators, 14 mm 1 ppm 1s 0.2% from span 0.01% from span for 1 °C
Operating conditions Operating temperature Operating humidity Storage temperature
0...50 °C 0...85 %RH, non-condensing -10...60 °C
Design and materials Case material Inlet material Housing dimensions (no connector) Wiring Sensor protection Sintered filter (option) Protection class Mounting Process connection Gas inlet length Weight
ABS/PC plastic POM plastic 80x80x70 mm 4-pin М12 connector (2) plastic cap with polyester filter stainless steel, 75 µm IP65 (excluding gas inlet) free (3) duct (4) none movable flange 130 mm 30 mm max. 250 g max. 350 g
(1)
Including nonlinearity error Straight or angles female part included Radial and axial mounting accessories can be ordered separately (see 'Accessories') (4) Small POM flange DN16.5. (2)
(3)
Ordering code
PHG - G0.G6.G9.G11.G15 - #1.#2
Code Feature or option
Code values free mounting
B - bottom connector, T - top connector
duct mounting
DB - bottom mounted connector, DT - top mounted connector
G0
Case
G6
Input range
03 - 0…3000 ppm, 05 - 0…5000 ppm, 10 - 0…10000 ppm
G9
Serial interface
X - none, A - RS232
G11
Output signal
E - 0…20 mA, F - 4…20 mA, K - 0…10 V, Z - other (specify!)
G15
Connector
C1A - angled M12 connector, C1S - straight M12 connector
#1
Sintered filter
X - none, S - sintered filter mounted
#2
Local indicator
X - none, A - local indicator mounted * contact COMECO
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
electrochemical control equipment Dissolved-Oxygen Transmitter PHO2 ♦ ♦ ♦ ♦ ♦ ♦ ♦
Input signal from SENSOREX, INGOLD, or compatible probes Temperature compensation input Built-in source for probe polarization voltage Rechargeable battery for probe polarization voltage Standard current or voltage output signal Isolated current output available Polarization-control front-panel switch
PHO2 is an electronic transmitter of dissolved-oxygen measurements. It transforms the signal from a standard INGOLD® or SENSOREX® probe for dissolved O2 or a compatible one, provides the polarization voltage necessary for the INGOLD probe operation, and performs measurement temperature compensation. A built-in rechargeable battery maintains INGOLD probe polarization even in absence of power supply, while a front-panel switch enables turning the polarization voltage off. The PHO2 transducer provides a standard voltage or current output signal that allows connection of any standard control, data logging, or indication device, with its field of application including the biotechnological, chemical, food, etc. industries as well as research.
Technical specifications Input Input signal Dissolved O2 input range Temperature compensation input Polarization voltage
'A' 0...50 mV 0% (pure N2) ... 100% (normal air) internal, 0...50 °C -
'B' 0...67 nA 0% (pure N2) ... 100% (normal air) external NTC 22 kΩ, 0...70 °C 675 mV DC
Accuracy < ± 1% from span < ± 1% from span 0.01% from span for 1 °C < 30 s (at change 0…95%) < ± 0.1 mV
Measurement error Repeatability Temperature drift Response time Polarization voltage (1)
Output Transmission range 0...100%, 0...200%, or 0...300% Output signal 0...20 mA 0…2 V 4...20 mA Input / output isolation (option) 1500 VAC for 1 min none none Minimum output load - 20 kΩ Maximum output load 350 Ω at 20 mA 350 Ω at 20 mA -
Mains supply voltage Isolated low voltage Consumption Polarization rechargeable battery (1) Rechargeable-battery service life (1)
230 VAC or 115 VAC 12…24 V or 24 VAC max. 2 VA 3.6 VDC min. 3 years
Operating conditions Ambient temperature Ambient humidity
0...55 °C 10...85 %RH
Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals Increased front IP (option)
plastic in 90x42 mm panel cut-out plug-in terminals 96x48(front)x107 mm 98 mm max. 400 g IP54 / IP20 IP65
With INGOLD® probes only!
Ordering code
PHO2 - G1.G6.G11'11" - #1.#2
Code Feature or option
Code values
G1
Power supply
A - 230 VAC, B - 115 VAC, Q - 12…24 V, isolated (2), R - 24 VAC
G6
Input
A - from SENSOREX® probe, B - from INGOLD® probe, Z - from other probe (specify probe output!)
G11'
Output signal
E - 0…20 mA, F - 4…20 mA, H - 0…2 V, Z - other (specify!)
G11"
Transmission range
(RANGE) (see table above)
#1
Input / output isolation
X - none, I - isolated output (3)
#2
Increased front protection
X - none, P - IP65 front protection
(2)
Ask for availability! (3) Available only for 4...20 mA output! Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(1)
Power supply
transmitters Analog Signal Isolator TRIL ♦ ♦ ♦ ♦ ♦ ♦
Low cost Passive and active variants 4…20 to 4…20 mA conversion 3750 VAC isolation level Increased input protection Mounting on DIN rail or in IP65 protection box
COMECO's signal isolator TRIL is a compact 2-wire current-to-current transmitter providing optical isolation of 3750 VAC between the input and output current loops. TRIL is available in 2 variants: - passive: an entirely passive device, which does not generate any supply voltages and does not need any additional supply to operate; the input part is powered by the input current loop (4…20 mA), and the output part is powered by the output current loop; - active: uses the energy of the output loop power supply (3-wire connection) to generate an isolated supply voltage for the input loop; provides an increased input over-voltage and over-current protection. TRIL is designed for mounting on a 35 mm DIN rail according to EN 50022, but it can be also enclosed in an IP65 protection box for wall mounting.
Technical specifications Input Input current Operating range Maximum admissible current Loop supply voltage Surge-voltage protection Over-voltage protection Over-current protection
Output Output current Operating range Over-scale limit Loop supply voltage Consumption Maximum line load Output signal at input failure Over-voltage protection Input / output isolation (1) (2) (3)
'0' '1' 4...20 mA 4...20 mA 3.5...21 mA 3.5...21 mA 50 mA 50 mA 10...30 VDC 4...36 VDC (1) 6.8 V (1) 6.8 V (1) 39 V , 90 V (2) none 40 mA none '0' '1' 4...20 mA 4...20 mA 3...22 mA 3...22 mA 32 mA 32 mA 8...32 VDC, 2-wire 24 VDC ± 10%, 3-wire max. 2 W 620 Ω at 24V/20mA 620 Ω at 24V/20mA < 2 mA < 2 mA 39 V (1) 39 V (1) 3750 VAC for 1 min 3750 VAC for 1 min
Accuracy Total measurement error Temperature drift Loop supply influence
0.35% from span 0.03% from span for 1 °C negligible
Operating conditions Ambient temperature Ambient humidity Storage temperature
-20...70 °C 0...95 %RH, non-condensing -40...85 °C
Design and materials Case material Wiring Mounting Dimensions Weight Protection class
on rail 18x90x58 mm 50 g IP20
plastic screw terminals in box (3) 80x80x60 mm 120 g IP65
Surge Zener diode Gas-discharge arrester May be mounted on rail by a special snap-on accessory, which is ordered separately (see 'Accessories').
Ordering code
TRIL - G12
Code Feature or option
0 - passive, 1 - active
Mounting
C - on DIN rail, D - in box IP65 (box included) (3)
COMECO reserves the right of changing specifications without prior notice!
G12
Code values
Variant
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
transmitters Analog Signal Isolator TRIL ♦ ♦ ♦ ♦ ♦ ♦
Low cost Passive and active variants 4…20 to 4…20 mA conversion 3750 VAC isolation level Increased input protection Mounting on DIN rail or in IP65 protection box
COMECO's signal isolator TRIL is a compact 2-wire current-to-current transmitter providing optical isolation of 3750 VAC between the input and output current loops. TRIL is available in 2 variants: - passive: an entirely passive device, which does not generate any supply voltages and does not need any additional supply to operate; the input part is powered by the input current loop (4…20 mA), and the output part is powered by the output current loop; - active: uses the energy of the output loop power supply (3-wire connection) to generate an isolated supply voltage for the input loop; provides an increased input over-voltage and over-current protection. TRIL is designed for mounting on a 35 mm DIN rail according to EN 50022, but it can be also enclosed in an IP65 protection box for wall mounting.
Technical specifications Input Input current Operating range Maximum admissible current Loop supply voltage Surge-voltage protection Over-voltage protection Over-current protection
Output Output current Operating range Over-scale limit Loop supply voltage Consumption Maximum line load Output signal at input failure Over-voltage protection Input / output isolation (1) (2) (3)
'0' '1' 4...20 mA 4...20 mA 3.5...21 mA 3.5...21 mA 50 mA 50 mA 10...30 VDC 4...36 VDC (1) 6.8 V (1) 6.8 V (1) 39 V , 90 V (2) none 40 mA none '0' '1' 4...20 mA 4...20 mA 3...22 mA 3...22 mA 32 mA 32 mA 8...32 VDC, 2-wire 24 VDC ± 10%, 3-wire max. 2 W 620 Ω at 24V/20mA 620 Ω at 24V/20mA < 2 mA < 2 mA 39 V (1) 39 V (1) 3750 VAC for 1 min 3750 VAC for 1 min
Accuracy Total measurement error Temperature drift Loop supply influence
0.35% from span 0.03% from span for 1 °C negligible
Operating conditions Ambient temperature Ambient humidity Storage temperature
-20...70 °C 0...95 %RH, non-condensing -40...85 °C
Design and materials Case material Wiring Mounting Dimensions Weight Protection class
on rail 18x90x58 mm 50 g IP20
plastic screw terminals in box (3) 80x80x60 mm 120 g IP65
Surge Zener diode Gas-discharge arrester May be mounted on rail by a special snap-on accessory, which is ordered separately (see 'Accessories').
Ordering code
TRIL - G12
Code Feature or option
0 - passive, 1 - active
Mounting
C - on DIN rail, D - in box IP65 (box included) (3)
COMECO reserves the right of changing specifications without prior notice!
G12
Code values
Variant
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
transmitters Intelligent Signal Isolator TRI ♦ ♦ ♦ ♦ ♦
Input and output powered by the current loops 4…20 to 4…20 mA or 4…20 to 20…4 mA selectable conversion Up to 4000 VAC isolation level 7 selectable thermocouple linearization blocks Mounting on DIN rail or in IP65 protection box
COMECO's signal isolator TRI is a compact 2-wire current-to-current transmitter providing optical isolation between the input and output current loops. The isolation level is normally 2500 VAC, but can be increased optionally to 4000 VAC. The TRI current isolator is an entirely passive device – it does not generate any supply voltages and does not need any additional supply for operating. The input part is powered by the input current loop (4…20 mA) and the output part is powered by the output current loop. Thanks to the use of high sophisticated electronics for its manufacturing, the TRI isolator offers some special features that can be activated by the user via internal programming jumpers: - direct (4…20 to 4…20 mA) or reversed (4…20 to 20…4 mA) conversion; - "Low" (3 mA) or "High" (22 mA) output status at input failure; - thermocouple non-linear conversions providing temperature linear output. TRI is designed for mounting on a 35 mm DIN rail according to EN50022, but it can be also enclosed in an IP65 protection box for wall mounting.
Technical specifications Input
Isolation
Input current Operating range Maximum admissible current Loop supply voltage Input voltage drop
4...20 mA 3.5...21 mA 50 mA 3...36 VDC less than 2.6 V
Output 4...20 mA or 20...4 mA 3...22 mA 32 mA 8...32 VDC 620 Ω at 24V/20mA 3 mA or 22 mA, selectable
Output current Operating range Over-scale limit Loop supply voltage Maximum line load Output signal at input failure (1)
Conversion Linear conversion direct Linear conversion reversed Non-linear conversions (1) (2)
(selectable) input 4 mA → output 4 mA input 20 mA → output 4 mA 7 selectable thermocouple ranges: 3 "J" and 4 "K"
Input / output isolation Increased isolation (option)
2500 VAC for 1 min 4000 VAC
Accuracy Total measurement error Temperature drift Loop supply influence
0.1% from span 0.01% from span for 1 °C negligible
Operating conditions Ambient temperature Ambient humidity Storage temperature
-20...70 °C 0...95 %RH, non-condensing -35...85 °C
Design and materials Case material Wiring Mounting Dimensions [mm] Weight Protection class
on rail 18x75x60 50 g IP20
plastic screw terminals in box (2) 80x80x60 120 g IP65
Outside the input operating range May be mounted on rail by a special snap-on accessory, which is ordered separately (see 'Accessories').
Ordering code
TRI - G12 - #1
Code Feature or option
Code values
Mounting
C - on DIN rail, D - in box IP65 (box included) (2)
#1
Increased isolation level
X - none (standard isolation rate), HI - 4000 VAC
COMECO reserves the right of changing specifications without prior notice!
G12
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
transmitters Universal Signal Isolator TRIM ♦ ♦ ♦ ♦ ♦ ♦ ♦
Input / output / supply triple isolation Accepts mA, mV, V, or Ω linear signals Positive and negative mA or V output Built-in digital filter Direct and reverse conversion Full digital technology – no analog adjustments DIN-rail case and 11-pin box for rail mounting
COMECO's signal isolator TRIM is an active triple-isolated transmitter with separate isolated power supply with 1000 VAC isolation level. The input part is internally powered and generates 24 VDC excitation voltage for external devices connected to TRIM input (current loops, transmitters, etc.). The input may accept various mA, mV, V (unipolar and bipolar) as well as resistive linear signals. The output part is internally energized and generates standard or custom specified linear current or voltage (positive or negative) signals. Thanks to the use of high sophisticated electronics for its manufacturing, the TRIM isolator offers some special features that can be activated by the user via internal programming jumpers: - direct or reversed conversion; - upscale or downscale output status at input failure; - custom specified non-linear conversions. TRIM is available in a case for mounting on a 35 mm DIN rail according to EN50022 and in a convenient 11-pin box for socket mounting.
Technical specifications Input
Accuracy
Linear current Linear voltage Linear resistive Custom linear (option) Current-input impedance Voltage-input impedance Input isolation
0...5 mA, 0(4)...20 mA 0...50 mV, 0...100 mV, 0...1 V, -1...1 V, 0...2 V, 0...5 V, 0...10 V, -10...10 V 0...1 kΩ min. -10...max. 10 V (1), 0...max. 100 mA (1), 0...100 Ω...100 kΩ (1) max. 10 Ω min. 1 GΩ (1 MΩ for range span > 1.5 V) > 1000 VAC for 1 min
Output Linear current Liner voltage Custom linear (option) Current-output load Voltage-output load Direct or reverse conversion Output signal at input failure Output isolation Excitation voltage (2) (3)
Power supply 12…24 V max. 100 mA > 1000 VAC for 1 min
Supply voltage Consumption Isolation
Operating conditions Ambient temperature Ambient humidity
Design and materials Dimensions [mm] Mounting Maximum weight [g] Protection class Case material Wiring
-20...70 °C 0...95 %RH, non-condensing 'R1'
'R2'
23x90x58 35x78x91 in socket or on rail on rail 180 80 IP20 IP20 plastic plastic screw terminals socket UNDECAL (3)
On request. Specify range additionally! Minimum 50 kΩ for negative output voltage ranges! Ordered separately (see 'Accessories').
Ordering code
TRIM - G0.G6.G11
Code Feature or option
Code values
G0
Case
R1 - for rail mounting, R2 - 11-pin box
G6
Input signal
A - 0…5 mA, B - 0…20 mA, C - 4…20 mA, F - 0…50 mV, G - 0…100 mV, H - 0…1 V, H1 - -1…1 V, I - 0…2 V, J - 0…5 V, K - 0…10 V, K1 - -10…10 V, L - resistance, Z - other
G11
Output signal
B - 0…5 mA, C - 1…5 mA, D - 2…10 mA, E - 0…20 mA, F - 4…20 mA, G - 0…1 V, H - 0…2 V, I - 0…5 V, J - 1…5 V, K - 0…10 V, L - 2…10 V, Z - other
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(1)
0(1)...5 mA, 2...10 mA, 0(4)...20 mA 0...1 V, 0...2 V, 0(1)...5 V, 0(2)...10 V on request (1) max. 620 Ω min. 1 kΩ (2) selectable upscale or downscale, selectable > 1000 VAC for 1 min 24 VDC, max. 30 mA
0.1% from span 0.01% from span for 1 °C negligible
Measurement error Temperature drift Power supply influence
transmitters AC/DC Current Transmitter TRT ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
Low cost 100% 2-wire AC/DC transmission Case for mounting inside current transformers available Reliable and accurate conversion High EMS suppression Input isolation option ZERO and SPAN adjustment In-head and DIN-rail versions
The current-to-current transmitter TRT is designed to convert alternative current signal coming from current transformers into a standard 2-wire current signal, which is more suitable for transmitting. Together with a current transformer, the TRT unit forms an AC/DC current converter suitable to measure big AC currents up to more than 1000 A. The 4...20 mA output can be used for measuring, regulation, and registration in special control systems. The TRT transmitter is based on modern integrated circuits and is a fixed-range transmitter. Its input ranges cover most popular current transformer output signals (0...1 A, 0...5 A) and customer specified inputs as well. TRT is available in a casing for mounting inside a current transformer, in 2 casings for DIN-rail mounting as well as mounted into an IP65 protection box, as the latter 3 versions can be equipped with an optional input isolation. TRT is an easy-to-use, low-cost, and EMSprotected device. Its application area includes power stations, electrical equipment, and electricity production and distribution. This transmitter can also be used as sensor transducer in various industrial control systems and everywhere, where AC to DC current conversion is desirable.
Technical specifications Input
Power supply
Input signal Frequency Input range Other input ranges Input isolation (option) (1)
alternative current 50/60 Hz 0…1 A or 0…5 A 0…max. 10 A internal current transformer
Output Output signal Current limits ZERO and SPAN adjustment Maximum line load
4...20 mA, 2-wire Low = 3 mA, High = 28 mA ± 10%, via trimpots 800 Ω at 24V/20mA
Accuracy Measurement error at 25 °C Non-linearity Temperature drift Supply voltage variation influence
0.5% from span 0.5% from span (up to 1.0% w/ input isolation) 0.1% from span for 1 °C 0.02% from span for 1 V
Mains supply voltage (2) Isolated low voltage (2) Non-isolated low voltage Admissible variations
230 VAC or 115 VAC 12...24 V 8...32 VDC 10% p-p at 50 Hz
Operating conditions Ambient temperature Ambient humidity: - mounted in a transformer - mounted on a rail - mounted in a box
-20...70 °C 0...80 %RH, non-condensing 0...95 %RH, non-condensing 0...95 %RH
Design and materials Mounting Dimensions [mm] Weight Protection, case/terminals Case material Wiring
free in box (3) on rail in socket (4) 43x33x16 80x80x60 35x110x58 35x78x91 110 g 180 g 20 g 90 g IP65 IP20 IP40/20 IP20 plastic plastic plastic plastic screw socket screw plug-in terminals terminals terminals UNDECAL (5)
(1)
Not available for the version for free mounting (G12 = "B")! Only for the version for mounting in socket May be mounted on rail by a special snap-on accessory, which is ordered separately (see 'Accessories'). (4) May be also mounted on a DIN rail (5) Ordered separately (see 'Accessories') (2)
Ordering code
TRT - G1.G6.G12 - #1
Code Feature or option
(6)
Code values
G1
Power supply
D - 8...32 VDC, non-isolated, A - 230 VAC (2), B - 115 VAC (2), Q - 12…24 V, isolated (2)
G6
Input
EQ - 0…1 AAC, ER - 0…5 AAC, EZ - other (6)
G12
Mounting
B - free (bare module), C1 - on DIN rail, C2 - in socket, D - in box IP65 (box included) (3)
#1
Input isolation
X - none, I - input isolation (1)
Specify upper current limit within the range given in the 'Input' table section above.
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(3)
transmitters Analog Load-Cell Transmitter TRW ♦ ♦ ♦ ♦ ♦ ♦
Low cost and small size 10 V excitation voltage 1 mV/V minimum input range Minimum 120 Ω load cell resistance 3-wire current or voltage output High protection class – IP67
With its IP67 cast aluminum enclosure, the TRW analog load-cell transmitter has been specially designed to be used in harsh industrial environments. This model can power a single 120...350 Ω load cell with 10 V bridge excitation voltage. TRW accepts 1, 2, or 3 mV/V input signal and generates a standard linear output signal that can be safely sent over long distances to remote indicators, data loggers, or controllers. ZERO and SPAN adjustments can be performed by the means of built-in potentiometers. TRW is low-priced and can withstand considerable electromagnetic disturbances. It can be a preferable low-cost solution for general-purpose process weighting as well as tension measurement applications.
Technical specifications Input
Accuracy single load cell 10 GΩ 120...350 Ω 1, 2, or 3 mV/V 10 VDC ± 0.05% 10, 20, or 30 mV min. ± 10% low-pass, fixed (≈ 10 Hz)
Input type Input impedance Load cell resistance Input sensitivity Bridge excitation voltage Full-scale input range ZERO and SPAN adjustment Analog filter
Output
0.15% from span 0.01% from span for 1 °C
Power supply Supply voltage Admissible variations
15...35 VDC 10% p-p at 50 Hz
Operating conditions Ambient temperature Ambient humidity
-20...60 °C 0...95 %RH
Design and materials
Output signal Minimum output load Maximum output load Output-error signal (NC) Current limit (1)
Measurement error Temperature drift
4(0)...20 mA 750 Ω at 24V/20 mA open collector, 36V/20mA 24...44 mA
0…10 V 1 MΩ open collector, 36V/20mA max. 42 ± 6 mA
Case material Mounting Wiring Dimensions Weight Protection class
aluminum free (1) screw terminals, 2 PG7 glands 77x82x58 mm (w/o glands) max. 210 g IP67
Radial, axial, and DIN-rail mounting accessories can be ordered separately (see 'Accessories').
Ordering code
TRW - G6.G11
Code Feature or option
Code values
Input
OL1 - 1 mV/V, OL2 - 2 mV/V, OL3 - 3 mV/V
G11
Output signal
E - 0…20 mA, F - 4…20 mA, K - 0…10 V, Z - other (specify!)
COMECO reserves the right of changing specifications without prior notice!
G6
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
process indicators Low-cost Programmable Display TI08 ♦ ♦ ♦ ♦ ♦ ♦
Lowest cost 5 DIN cases - up to 1/32 DIN 4-digit bright LED indication Universal linear input Up to 2 alarm relays available with pulsed output Fully programmable parameters
TI08 is a cheap programmable process indicator available in 5 DIN cases and designed for wide range of display applications with/without relay alarm. Equipped with a bright 4-digit LED display, this model is especially suitable for measuring and controlling various technological values from -1999 to 9999 with resolution of up to 6000 points. The device may be equipped with up to 2 programmable relays providing ON/OFF control/alarm with or without pulse mode. TI08 accepts various linear input voltage or current signals. The display limits, decimal point position, measurement offset value as well as many other parameters are fully programmable. Thanks to its excellent price-to-performance ratio, TI08 is an exceptionally widely applicable device.
Technical specifications Input Linear voltage 0...10 V Linear voltage 0...5 V (1) Linear current 0(4)...20 mA Custom linear (option) Two-wire external transmitter Decimal point selection
(programmable) -1999...9999, programmable -1999...9999, programmable -1999...9999, programmable -1999...9999, programmable 4...20 mA (2) programmable (up to 2 relay outputs (3))
Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Alarms
5A/250V w/ NO/NC (4) contact 1A/250VAC (5) 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF, pulse mode programmable
Accuracy 0.3% from span 0.02% from span for 1 °C
Measurement error Temperature drift
Operating conditions -10...65 °C 0...85 %RH
Operating temperature Operating humidity
Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage External mains transformer (6) Consumption
230 VAC (1) or 115 VAC (1) 90…250 VAC/DC (1) 12…24 VAC/DC or 24 VAC (1) 12…24 VAC/DC 9(12) VAC max. 1.5 VA
Indication and controls Digital display LEDs Keyboard
Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals)
4 LED indicators 2 LEDs for output state 2 membrane keys, lockable 'B' 'H' 'S' 'L' 'M' 96x96 96x48 48x48 72x36 48x24 panel panel panel panel panel 90x90 90x42 45x45 71x29 46x22 98 56 98 100 42 14 14 20 10 9 250 150 350 200 30 IP54/20 IP54/20 IP54/20 IP54/20 IP54/20 IP65 IP65 IP65 (7) plastic plastic plastic plastic plastic plug-in plug-in screw screw screw
(1)
Not available for case 'M' Provides loop supply voltage - 24 VDC (only w/ isolated power supply) Only one for case 'M' (4) For case 'S' 2nd relay is NO; for case 'L' both relays are NO; for case 'M' relay is 3A/250VAC with NO contact (5) 0.2A/250VAC for cases 'L' and 'M' (6) Ordered separately (see 'Accessories') (7) Ask for availability! (2)
(3)
TI08 - G0.G1.G5G5 - #1.#2
Code Feature or option
(8)
Code values
G0
Case (front size)
B - 96x96 mm, H - 96x48 mm, S - 48x48 mm, L - 72x36 mm, M - 48x24 mm
G1
Power supply
A - 230 VAC (1), B - 115 VAC (1), C - 90…250 V (1), E - 9(12) VAC w/ external transformer (6), P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC (1)
G5
Relay output (3)
X - none, C - relay NO/NC (4), D - SSR, J - for external SSR, M - isolated MOS gate
#1
Increased front protection
X - none, P - IP65 front protection (1,8)
#2
Customer specified input signal
X - none, Z - custom linear signal (specify!)
Not available for case 'S'
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
process indicators Programmable Trip-alarm Unit TI08-R ♦ ♦ ♦ ♦ ♦ ♦ ♦
Low cost 11-pin box for DIN-rail mounting 3-digit bright LED indication Universal linear input Up to 2 alarm relays available with pulsed output Auxiliary output for powering external transmitters Fully programmable parameters
TI08-R is a cheap programmable process indicator for DIN-rail mounting designed for trip-alarm applications. Equipped with a bright 3-digit LED display, this model is especially suitable for measuring and controlling various technological values from -199 to 999 with resolution of up to 1000 points. The device can have up to 2 programmable relays providing on/off control/alarm with or without pulse mode. TI08-R accepts various linear input voltage or current signals from 2- and 3-wire transmitters that can be powered internally via the auxiliary power supply output. The display-to-input correspondence, decimal point position, measurement offset value as well as many other parameters are fully programmable. Thanks to its excellent price-to-performance ratio, TI08-R is an exceptionally widely applicable device.
Technical specifications Input Linear voltage 0...10 V Linear voltage 0...5 V Linear current 0(4)...20 mA Two-wire external transmitter Decimal point selection
Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Alarms
(programmable) -199...999, programmable -199...999, programmable -199...999, programmable 4...20 mA (1) programmable (up to 2 relay outputs) 5A/250V w/ NO/NC (2) contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF, pulse mode programmable
Accuracy 0.3% from span 0.02% from span for 1 °C
Measurement error Temperature drift
Operating conditions -10...65 °C 0...85 %RH
Operating temperature Operating humidity (1) (2) (3)
Power supply Mains supply voltage Isolated low voltage Non-isolated low voltage External mains transformer (3) Consumption
230 VAC or 115 VAC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC 9(12) VAC max. 1.5 VA
Indication and controls Digital display LEDs Keyboard
3 LED indicators, 10 mm 2 LEDs for output state 3 membrane keys, lockable
Design and materials Case material Mounting Wiring Dimensions Weight Protection, front/terminals
plastic in socket or on 35 mm DIN rail socket UNDECAL (3) 35x78x91 mm 180 g IP44 / IP20
Provides loop supply voltage - 24 VDC (only w/ isolated power supply) NO for the 2nd relay Ordered separately (see 'Accessories')
Ordering code
TI08 - R.G1.G5G5
Code Feature or option
Code values
Power supply
G5
Relay output
X - none, C - relay NO/NC (2), D - SSR, J - for external SSR, M - isolated MOS gate
COMECO reserves the right of changing specifications without prior notice!
G1
A - 230 VAC, B - 115 VAC, E - 9(12) VAC w/ external transformer (3), P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
process indicators Programmable Process Indicator TC660 ♦ ♦ ♦ ♦ ♦ ♦ ♦
20 mm or 32 mm digit height Universal programmable input 2 programmable alarm outputs Programmable digital filter Calibration and self-calibration Isolated current output RS485 serial interface available
TC660 is a multifunctional programmable process indicator with a 4-digit, 20 mm or 32 mm programmable display that provides excellent visibility in many applications. The device has a universal input for the most common thermoresistances, thermocouples, and linear signals. The input has a built-in automatic software compensation of line resistance and cold junction temperature as well as automatic software compensation of temperature drift, and can be calibrated manually. A programmable input filter and various options for access restriction are available. TC660 can also have up to 2 programmable alarm outputs (2 relays or 1 relay and 1 analog output) and can be equipped with an isolated RS485 serial interface. Input Technical
specifications
Pt100 (w=1.385, 1.391); 3-wire Cu100 (w=1.426, 1.428); 3-wire Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" Thermocouple "C" Thermocouple "L - GOST" Linear voltage 0...50 mV (1) Linear current 0...20 mA Linear current 4...20 mA Input type selection Decimal point selection Digital filter Input calibration
Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Operation modes Control algorithms Auto-tuning Alarms Other control features Analog output (3) Serial interface
(programmable) -100...600 °C -50...200 °C 0...1000 °C 0...1300 °C 0...1700 °C 0...1700 °C 100...1800 °C 0...2300 °C 0...600 °C -1999...9999, programmable -1999...9999, programmable -1999...9999, programmable (2) programmable programmable programmable programmable (up to 2 outputs) 5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA manual and automatic ON/OFF, PID-pulse, and PID for motor valves, programmable programmable programmable BUMPLESS and ANTI-WINDUP 4(0)...20 mA or 0...10 V, isolated RS485, isolated
Accuracy 0.3% (4) from span 0.01% from span for 1 °C automatic software automatic software automatic software
Measurement error Temperature drift Self-calibration Cold junction compensation RTD line compensation
Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption
230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 5 VA
Indication and controls 4 LED indicators 2 LEDs for output state 3 membrane keys
Digital display LEDs Keyboard
Operating conditions Operating temperature Operating humidity
Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring
'H' 96x48 panel 90x42 98 20 400 IP54 / IP20 IP65 plastic plug-in terminals
-10...55 °C 0...85 %RH 'D' (5) 144x72 panel 136x66 92 32 600 IP54 / IP20 plastic plug-in terminals
(1)
Other voltage ranges can be obtained by the means of 2 external resistors. Provides loop supply voltage - 24 VDC (only w/ isolated power supply) Instead of 1st relay! If mounted, it can be programmed as control or retransmission! (4) 0.5% for T/Cs "S", "R", "B", and "C" (5) Ask for availability! (3)
Ordering code
TC660 - G0.G1.G5G5.G9'9".G11 - #1
Code Feature or option
(6)
Code values
G0
Case (front size)
H - 96x48 mm, D - 144x72 mm (5)
G1
Power supply
A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
G5
Relay output
X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate
G9'
Serial interface
X - none, B - RS485
G9"
Protocol
A - ASCII, C - ASCII for "PolyMonitor"
G11
Analog output (3)
X - none, E - 0…20 mA, F - 4…20 mA, K - 0…10 V
#1
Increased front protection
X - none, P - IP65 front protection (6)
Available ONLY for case 'H'
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(2)
process indicators Programmable Process Indicator TC67U ♦ ♦ ♦ ♦ ♦ ♦ ♦
Low cost Large LED display up to 45 mm high Universal input for 4 RTDs, 6 T/Cs, and 3 linear types 2 alarm relay outputs Software input line and 'cold junction' correction Self-testing and self-calibration RS485 serial interface available
TC67U is designed for wide range of control applications. It is equipped with a large LED display and 2 programmable relay alarm outputs. TC67U has a universal input accepting signals from Pt100, Pt1000, PTC, 6 thermocouple types as well as linear current and voltage signals from external transmitters. This device also has a built-in circuit for self-testing and self-calibration, manual measurement offset setting, and automatic software compensation of line resistance and cold junction temperature. The display-to-input correspondence (in case of linear input), decimal point position, temperature measurement unit, and offset value are also programmable through the convenient keyboard. Thanks to its large display, universal input, serial interface, and excellent price-to-performance ratio, TC67U is exceptionally widely applicable device.
Technical specifications (programmable)
Pt100 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire PTC (1k at 25 °C); 3-wire PTC (2k at 25 °C); 3-wire Thermocouple "T" Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" Linear voltage 0...10 V Linear current 0(4)...20 mA Custom linear (option) (3) Two-wire external transmitter Manual input offset Input type selection Decimal point selection Temperature measurement unit
Outputs
-100...850 °C -100...600 °C -50...150 °C -50...150 °C -40...400 °C -20...1000 °C -20...1300 °C (1) 0...1700 °C (1) 0...1700 °C (1) 100...1800 °C (1) -1999...9999 (2), programmable -1999...9999 (2), programmable -1999...9999 (2), programmable 4...20 mA (4) programmable programmable programmable °C or °F, programmable (up to 2 relay outputs)
Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Alarms Serial interface
5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF within input range limits programmable RS485, isolated
Accuracy Measurement error Temperature drift Cold junction compensation RTD line compensation
Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption
3 or 4 LED indicators 2 LEDs for output state 3 membrane keys
Digital display LEDs Keyboard
Operating conditions Operating temperature Operating humidity
Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digits Display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals) (4)
(2)
(5)
Ordering code
230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 2 VA
Indication and controls
(1)
Up to 1000 °C for case 'D3' -199...999 for case 'D3' (3) Instead of linear current
0.3% from span 0.02% from span for 1 °C automatic, -10...80 °C automatic, up to 2 х 25 Ω
(6)
'H' 96x48 panel 90x42 98 4 20 400 IP54/20 IP65 (5) plastic plug-in
'D3' 144x72 panel 136x66 92 3 45 600 IP54/20 plastic plug-in
Provides loop supply voltage - 24 VDC (only w/ isolated power supply) Double front panel sealing! Available ONLY for case 'H'
TC67U - G0.G1.G5G5.G9'9" - #1.#2
Code Feature or option
Code values
G0
Case (front size)
H - 96x48 mm, D3 - 144x72 mm w/ 3-digit display, D4 - 144x72 mm w/ 4-digit display
G1
Power supply
A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
G5
Relay output
X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate
G9'
Serial interface
X - none, B - RS485
G9"
Protocol
A - ASCII, C - ASCII for "PolyMonitor"
#1
Increased front protection
X - none, P - IP65 front protection (6)
#2
Customer specified input signal
X - none, Z - custom linear signal (specify!) (3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
-10...65 °C 0...85 %RH 'D4' 144x72 panel 136x66 92 4 32 600 IP54/20 plastic plug-in
COMECO reserves the right of changing specifications without prior notice!
Input
process indicators Programmable Process Indicator TC67U ♦ ♦ ♦ ♦ ♦ ♦ ♦
Low cost Large LED display up to 45 mm high Universal input for 4 RTDs, 6 T/Cs, and 3 linear types 2 alarm relay outputs Software input line and 'cold junction' correction Self-testing and self-calibration RS485 serial interface available
TC67U is designed for wide range of control applications. It is equipped with a large LED display and 2 programmable relay alarm outputs. TC67U has a universal input accepting signals from Pt100, Pt1000, PTC, 6 thermocouple types as well as linear current and voltage signals from external transmitters. This device also has a built-in circuit for self-testing and self-calibration, manual measurement offset setting, and automatic software compensation of line resistance and cold junction temperature. The display-to-input correspondence (in case of linear input), decimal point position, temperature measurement unit, and offset value are also programmable through the convenient keyboard. Thanks to its large display, universal input, serial interface, and excellent price-to-performance ratio, TC67U is exceptionally widely applicable device.
Technical specifications (programmable)
Pt100 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire PTC (1k at 25 °C); 3-wire PTC (2k at 25 °C); 3-wire Thermocouple "T" Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" Linear voltage 0...10 V Linear current 0(4)...20 mA Custom linear (option) (3) Two-wire external transmitter Manual input offset Input type selection Decimal point selection Temperature measurement unit
Outputs
-100...850 °C -100...600 °C -50...150 °C -50...150 °C -40...400 °C -20...1000 °C -20...1300 °C (1) 0...1700 °C (1) 0...1700 °C (1) 100...1800 °C (1) -1999...9999 (2), programmable -1999...9999 (2), programmable -1999...9999 (2), programmable 4...20 mA (4) programmable programmable programmable °C or °F, programmable (up to 2 relay outputs)
Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Alarms Serial interface
5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF within input range limits programmable RS485, isolated
Accuracy Measurement error Temperature drift Cold junction compensation RTD line compensation
Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption
3 or 4 LED indicators 2 LEDs for output state 3 membrane keys
Digital display LEDs Keyboard
Operating conditions Operating temperature Operating humidity
Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digits Display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals) (4)
(2)
(5)
Ordering code
230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 2 VA
Indication and controls
(1)
Up to 1000 °C for case 'D3' -199...999 for case 'D3' (3) Instead of linear current
0.3% from span 0.02% from span for 1 °C automatic, -10...80 °C automatic, up to 2 х 25 Ω
(6)
'H' 96x48 panel 90x42 98 4 20 400 IP54/20 IP65 (5) plastic plug-in
'D3' 144x72 panel 136x66 92 3 45 600 IP54/20 plastic plug-in
Provides loop supply voltage - 24 VDC (only w/ isolated power supply) Double front panel sealing! Available ONLY for case 'H'
TC67U - G0.G1.G5G5.G9'9" - #1.#2
Code Feature or option
Code values
G0
Case (front size)
H - 96x48 mm, D3 - 144x72 mm w/ 3-digit display, D4 - 144x72 mm w/ 4-digit display
G1
Power supply
A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
G5
Relay output
X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate
G9'
Serial interface
X - none, B - RS485
G9"
Protocol
A - ASCII, C - ASCII for "PolyMonitor"
#1
Increased front protection
X - none, P - IP65 front protection (6)
#2
Customer specified input signal
X - none, Z - custom linear signal (specify!) (3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
-10...65 °C 0...85 %RH 'D4' 144x72 panel 136x66 92 4 32 600 IP54/20 plastic plug-in
COMECO reserves the right of changing specifications without prior notice!
Input
process indicators Programmable Process Indicator TC67U ♦ ♦ ♦ ♦ ♦ ♦ ♦
Low cost Large LED display up to 45 mm high Universal input for 4 RTDs, 6 T/Cs, and 3 linear types 2 alarm relay outputs Software input line and 'cold junction' correction Self-testing and self-calibration RS485 serial interface available
TC67U is designed for wide range of control applications. It is equipped with a large LED display and 2 programmable relay alarm outputs. TC67U has a universal input accepting signals from Pt100, Pt1000, PTC, 6 thermocouple types as well as linear current and voltage signals from external transmitters. This device also has a built-in circuit for self-testing and self-calibration, manual measurement offset setting, and automatic software compensation of line resistance and cold junction temperature. The display-to-input correspondence (in case of linear input), decimal point position, temperature measurement unit, and offset value are also programmable through the convenient keyboard. Thanks to its large display, universal input, serial interface, and excellent price-to-performance ratio, TC67U is exceptionally widely applicable device.
Technical specifications (programmable)
Pt100 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire PTC (1k at 25 °C); 3-wire PTC (2k at 25 °C); 3-wire Thermocouple "T" Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" Linear voltage 0...10 V Linear current 0(4)...20 mA Custom linear (option) (3) Two-wire external transmitter Manual input offset Input type selection Decimal point selection Temperature measurement unit
Outputs
-100...850 °C -100...600 °C -50...150 °C -50...150 °C -40...400 °C -20...1000 °C -20...1300 °C (1) 0...1700 °C (1) 0...1700 °C (1) 100...1800 °C (1) -1999...9999 (2), programmable -1999...9999 (2), programmable -1999...9999 (2), programmable 4...20 mA (4) programmable programmable programmable °C or °F, programmable (up to 2 relay outputs)
Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Alarms Serial interface
5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF within input range limits programmable RS485, isolated
Accuracy Measurement error Temperature drift Cold junction compensation RTD line compensation
Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption
3 or 4 LED indicators 2 LEDs for output state 3 membrane keys
Digital display LEDs Keyboard
Operating conditions Operating temperature Operating humidity
Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digits Display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals) (4)
(2)
(5)
Ordering code
230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 2 VA
Indication and controls
(1)
Up to 1000 °C for case 'D3' -199...999 for case 'D3' (3) Instead of linear current
0.3% from span 0.02% from span for 1 °C automatic, -10...80 °C automatic, up to 2 х 25 Ω
(6)
'H' 96x48 panel 90x42 98 4 20 400 IP54/20 IP65 (5) plastic plug-in
'D3' 144x72 panel 136x66 92 3 45 600 IP54/20 plastic plug-in
Provides loop supply voltage - 24 VDC (only w/ isolated power supply) Double front panel sealing! Available ONLY for case 'H'
TC67U - G0.G1.G5G5.G9'9" - #1.#2
Code Feature or option
Code values
G0
Case (front size)
H - 96x48 mm, D3 - 144x72 mm w/ 3-digit display, D4 - 144x72 mm w/ 4-digit display
G1
Power supply
A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
G5
Relay output
X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate
G9'
Serial interface
X - none, B - RS485
G9"
Protocol
A - ASCII, C - ASCII for "PolyMonitor"
#1
Increased front protection
X - none, P - IP65 front protection (6)
#2
Customer specified input signal
X - none, Z - custom linear signal (specify!) (3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
-10...65 °C 0...85 %RH 'D4' 144x72 panel 136x66 92 4 32 600 IP54/20 plastic plug-in
COMECO reserves the right of changing specifications without prior notice!
Input
process indicators 8-channel Programmable Indicator TC800 ♦ ♦ ♦ ♦ ♦
8 inputs, 8 outputs, and 16 alarms 2 displays ─ for measured value and for channel number Programmable ranges and alarms Self-testing and system-failure alarm RS485 serial interface available
The TC800 indicator is designed for multi-point control of technological variables. With its compact design, 8 inputs and outputs, TC800 successfully performs all the tasks of indicating, monitoring, and signaling the level of several channels. With the proper programming, any of the channels may be turned into a 2-or 3-state ON/OFF controller and even into a multistage controller. Motorized actuators may be controlled by using 2 relay outputs. The device input accepts thermoresistances, thermocouples, or standard current and voltage signals. Additional discrete inputs are available for remote channel switching and tampering protection. TC800 performs digital compensation for RTD sensor line resistance as well as thermocouple cold-junction compensation, and constantly monitors sensor and sensor-lead state. A rich set of parameters allows programming every aspect of controller operation and an RS485 serial interface allows network operation or connection to operator station.
Technical specifications (2...8 inputs) Pt10…1000 (w=1.385, 1.391) -100(-200)...200(850) °C (1) Cu50, Cu100 (w=1.426, 1.428) -50(0)...200 °C (1) (1) Other RTD min. -200...max. 850 °C Thermocouple "J" 0...800 °C Thermocouple "K" 0...1200 °C Thermocouple "S" 0...1600 °C Thermocouple "R" 0...1600 °C Thermocouple "B" 200...1800 °C Thermocouple "L" 0...1200 °C Thermocouple "L - GOST" 0...600 °C Thermocouple "E" 0...1000 °C Thermocouple "T" 0...400 °C Thermocouple "U" 0...600 °C (1) Other thermocouple min. 0...max. 2400 °C Linear voltage 0...1/ 2/ 5/ 10 V -999...9999, programmable Linear current 0(4)...20 mA -999...9999, programmable (1) Custom linear voltage; max. 40 V min. -999...max. 9999, programmable Custom linear current; max. 50 mA (1) min. -999...max. 9999, programmable
Accuracy
Discrete inputs
Ambient temperature Ambient humidity
Input signal type Input 1 function Input 2 function
Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Alarms System-failure alarm Serial interface
(up to 2 inputs) contact, TTL, NPN, or PNP remote channel selection ext. programmed parameter protection (up to 9 relay outputs) (2) 3A/250V w/ NO (3) contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA up to 16, programmable activates SPDT EMR output No 9 RS485, isolated (4)
(1)
Measurement error Temperature drift Cold junction compensation RTD line compensation
0.4% from span 0.005% from span for 1 °C ± 1 °C, automatic software software
Power supply Mains supply voltage SMPS voltage Isolated low voltage Consumption
230 VAC or 115 VAC 90…250 V 12…24 V or 24 VAC max. 4 VA
Indication and controls Channel-number display Measured-value display LEDs Keyboard
2 green LED indicators, 14 mm 4 red LED indicators, 14 mm 8 LEDs for output state and 16 LEDs for alarm state 8 membrane keys
Operating conditions
Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals Increased front IP (option)
Custom; specify range within the limits stated. Relay No 9 is for system-failure alarm only (G10)! NO/NC for relay No 1 (4) With ASCII protocol, the outputs may be controlled only through the interface, and with binary protocol – only through the hardware! (2) (3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
-10...65 °C 0...85 %RH plastic in 90x90 mm panel cut-out plug-in terminals 96x96(front)x107 mm 98 mm max. 650 g IP54 / IP20 IP65
COMECO reserves the right of changing specifications without prior notice!
Analog inputs
process indicators
Ordering code
TC800 - G1.G5─G5.G6'6"─G6'6".G7G7.G9'9".G10 - #1
Code Feature or option
Code values
G1
Power supply
A - 230 VAC, B - 115 VAC, C - 90…250 V, Q - 12…24 V, isolated, R - 24 VAC
G5
Relay output
X - none, A - relay NO (3), D - SSR, J - for external SSR, M - isolated MOS gate
G6'
Input signal
G6"
Sensor
B - thermoresistance, C - thermocouple, D - linear, Z - other on request RTD
B - Pt50, D - Pt100, F - Pt500, G - Pt1000, H - Cu50, K - Cu100, Z - other (1)
T/C
B - "B", E - "E", J - "J", K - "K", L - "L", M - "L-GOST", S - "S", R - "R", T - "T", U - "U", Z - other (1)
linear
B - 0…20 mA, C - 4…20 mA, H - 0…1 V, I - 0…2 V, J - 0…5 V, K - 0…10 V, Z - other (1)
Discrete input
X - none, A - contact, E - NPN, F - PNP, G - TTL
G9'
Serial interface
X - none, B - RS485
G9"
Protocol
A - ASCII, B - binary, C - ASCII for "PolyMonitor", D - binary for "PolyMonitor"
G10
System alarm
X - none, S - system-failure alarm relay
#1
Increased front protection
X - none, P - IP65 front protection
COMECO reserves the right of changing specifications without prior notice!
G7
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
process indicators Slim-size Bargraph Indicator TC150 ♦ ♦ ♦ ♦ ♦ ♦ ♦
Low-cost Analog design Current and voltage input signals 24x96 mm DIN-sized front panel 30-dot LED bargraph Moving dot / bar modes available Custom-design bargraph and scale available
TC150 is a slim-sized process indicator for panel mounting with 24x96 mm DIN front size. It accepts linear voltage or current signals at its input and is equipped with a 30-dot vertical LED bargraph, indicating the input value as a percentage of the input range and thereby presenting a convenient 'analog' reading. In combination with a level transmitter, TC150 provides a handy level indication. Moving dot and moving bar modes of the bargraph display as well as custom bargraph design are available. Low priced, TC150 with its useful features and slim front design can be widely applicable for a vast range of industrial solutions.
Technical specifications Input (1)
Power supply
Linear voltage
0…10, 20, 50, or 100 mV, 0…1, 2, 5, or 10 V 0(4)…20 mA min. 0...max. 40 V DC min. 0...max. 100 mA DC
Linear current (2) Custom linear voltage Custom linear current (2)
Accuracy
SMPS voltage Isolated low voltage Non-isolated low voltage Consumption
90…250 VAC/DC 12…24 VAC/DC 12…24 VAC/DC max. 4 VA
Operating conditions Operating temperature Operating humidity
-10...65 °C 0...85 %RH
Design and materials
Resolution Temperature drift
3.33% from span 0.02% from span for 1 °C
Bargraph display Type Scale Mode Color
30 LED dots, 2 mm wide 0…100% or custom design (2) moving dot or moving bar (2) red, green, or yellow
Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals Increased front IP (option)
plastic in 21x93 mm panel cut-out plug-in terminals 24x96(front)x125 mm 120 mm max. 150 g IP54 / IP20 IP65
(1)
Provides loop supply voltage - 24 VDC (only w/ isolated power supply) Specify when ordering! (3) Ask for availability! (2)
Ordering code
TC150 - G1.G2.G6'6" - #1
Code Feature or option
Code values
Power supply
C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated
G2
Bargraph display
D1 - w/ moving dot, D2 - w/ moving bar, Z - custom design (specify!)
G6'6"
Input (1)
DA - 0...5 mA, DB - 0...20 mA, DC - 4...20 mA, DE - 0...10 mV, DF - 0...20 mV, DG - 0...50 mV, DH - 0...1 V, DI - 0...2 V, DJ - 0...5 V, DK - 0...10 V, DZ - other
#1
Increased front protection
X - none, P - IP65 front protection
COMECO reserves the right of changing specifications without prior notice!
G1
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail:
exp
process indicators Programmable Bargraph Display TI250 ♦ ♦ ♦ ♦ ♦ ♦ ♦
Tri-color fully programmable 30-dot LED bargraph 3-digit bright LED indication Universal linear input Up to 2 alarm relays available with pulsed output 48x96 mm DIN-sized front panel Moving dot / bar programmable modes Custom-design bargraph and scale available
TI250 is a versatile and non-expensive combination of TI08 programmable process indicator in 48x96mm DIN case and a fully programmable Tri-color LED bargraph. It is designed for wide range of display applications with/without relay alarm. Equipped with a bright 3-digit LED display, this model is suitable for measuring and controlling various technological values from -199 to 999 with programmable resolution. The device may be also equipped with up to 2 programmable relays providing ON/OFF control/alarm with or without pulse mode. TI250 bargraph display allows user programming of every LED dot color, dot/bar display mode as well as customized scale. Like TI08 the unit accepts various linear input voltage or current signals. Display limits, decimal point position, measurement offset value as well as many other parameters are fully programmable. Thanks to its rich display features and excellent price-to-performance ratio, TI250 can be a very useful and widely applicable device.
Technical specifications Input Linear voltage 0...10 V Linear voltage 0...5 V Linear current 0(4)...20 mA Custom linear (option) Two-wire external transmitter Decimal point selection
Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Alarms
(programmable) -199...999, programmable -199...999, programmable -199...999, programmable -199...999, programmable 4...20 mA (1) programmable (up to 2 relay outputs) 5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF, pulse mode programmable
Digital display Design Measurement accuracy Resolution Temperature drift
3 LED indicators, 10 mm 0.3% from span programmable 0.02% from span for 1 °C
Bargraph display Design Scale Mode Color (2) (3)
Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage External mains transformer (2) Consumption
230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC 9(12) VAC max. 3 VA
Indication and controls LEDs Keyboard
2 LEDs for output state 3 membrane keys, lockable
Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity
-10...65 °C 0...85 %RH -20...65 °C 0...95 %RH, non-condensing
Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals Increased front IP (option)
plastic in 42x90 mm panel cut-out plug-in terminals 48x96(front)x107 mm 98 mm max. 300 g IP54 / IP20 IP65
Provides loop supply voltage - 24 VDC (only w/ isolated power supply) Ordered separately (see 'Accessories') Specify when order!
Ordering code
TI250 - G1.G2.G5G5 - #1.#2
Code Feature or option
Code values
G1
Power supply
A - 230 VAC, B - 115 VAC, C - 90…250 V, E - 9(12) VAC w/ external transformer (2), P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
G2
Bargraph display scale
D - standard (0...100%), Z - custom design (specify!)
G5
Relay output
X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate
#1
Increased front protection
X - none, P - IP65 front protection
#2
Customer specified input signal
X - none, Z - custom linear signal (specify!)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(1)
30 LED dots, 2 mm wide 0…100% or custom design (3) programmable: dot or bar programmable: red, green, or yellow
Power supply
process indicators Bargraph Indicator TC66 ♦ ♦ ♦ ♦ ♦ ♦ ♦
Low-cost 4-digit LED display plus 50-dot bargraph Various input signals Well protected from electromagnetic disturbances Moving dot / bar modes available Auxiliary input for display brightness control Custom-design bargraph and scale available
In addition to the digital display, showing the exact value of the measured variable, the TC66 process indicator is equipped with a LED bargraph, indicating the input value as a percentage of the input range and thereby presenting more convenient 'analog' reading. Two variants of the indicator are available: one with a linear, horizontal bargraph ('D') and one with a bargraph in the shape of a 240-degree arc, which provides a visualization resembling that of a traditional pointer-and-dial gauge ('B'). Moving dot and moving bar modes of the bargraph display as well as custom bargraph design are available. Both TC66 variants feature a customized front-panel tag denoting the range and the measurement unit of the monitored physical quantity. The indicator may also be equipped with an auxiliary DC input for display brightness control. The low-priced, low-maintenance TC66 is widely applicable in boat building, power plants, and other industrial areas.
Technical specifications Input
Power supply
Linear voltage 0…10 mV (1) Linear voltage 0…20 mV (1) Linear voltage 0…50 mV (1) Linear voltage 0…100 mV (1) Linear voltage 0…1 V (1) Linear voltage 0…2 V (1) Linear voltage 0…5 V (1) Linear voltage 0…10 V (1) Linear current 0…5 mA (1) Linear current 0(4)…20 mA (1) Custom linear voltage; max. 40 V (1) Custom linear current; max. 50 mA (1) Decimal point position Display range Brightness control (option) (3)
min. -1999...max. 1999 (2) min. -1999...max. 1999 (2) min. -1999...max. 1999 (2) min. -1999...max. 1999 (2) min. -1999...max. 1999 (2) min. -1999...max. 1999 (2) min. -1999...max. 1999 (2) min. -1999...max. 1999 (2) min. -1999...max. 1999 (2) min. -1999...max. 1999 (2) min. -1999...max. 1999 (2) min. -1999...max. 1999 (2) x1, x0.1, x0.01, x0.001 specified by customer min. 0...max. 24 VDC
Accuracy 0.4% from span 0.02% from span for 1 °C
Measurement error Temperature drift
Indication and controls 4 LED indicators 50 LED dots, 0...100%
Digital display Bargraph display (4)
Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption
230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 4 VA
Operating conditions -10...65 °C 0...85 %RH
Operating temperature Operating humidity
Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digit height [mm] Bargraph shape Maximum weight [g] Protection, front/terminals Case material Wiring
'B'
'D'
96x96 panel 90x90 98 10 240° arc 650 IP54 / IP20 plastic plug-in terminals
144x72 panel 136x66 92 14 horizontal bar 650 IP54 / IP20 plastic plug-in terminals
(1)
Specify lower and upper display limits. Provides loop supply voltage - 24 VDC (only w/ isolated power supply) Specify range within the limits stated. (4) Custom display or/and scale design is also available. Ask!
(2)
Ordering code
TC66 - G0.G1.G2.G3.G6'6" - #1
Code Feature or option
Code values
G0
Case (front size)
B - 96x96 mm, D - 144x72 mm
G1
Power supply
A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
G2
Bargraph display
D1 - w/ moving dot, D2 - w/ moving bar, Z - custom design (specify!)
G3
Resolution
B - 1, C - 0.1, D - 0.01, E - 0.001
(1)
G6'6"
Input
#1
Auxiliary input
DA - 0...5 mA, DB - 0...20 mA, DC - 4...20 mA, DE - 0...10 mV, DF - 0...20 mV, DG - 0...50 mV, DH - 0...1 V, DI - 0...2 V, DJ - 0...5 V, DK - 0...10 V, DZ - other X - none, BC - input for brightness control mounted (3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(3)
process indicators Programmable Bargraph Indicator TC600 ♦ ♦ ♦ ♦ ♦ ♦
4-digit LED display plus 50-dot bargraph Various input signals and nonlinearities Programmable ranges and alarms Programmable relay and linear outputs Serial interface available Self-testing and self-calibration
TC600 is a microprocessor-based programmable process indicator with alarm relay outputs. In addition to the digital display, indicating the measured value, the device features a 50-dot LED bar-graph, showing the input value as a percentage of the input range. A changeable front-panel tag indicates the measurement unit. TC600 accepts standard current or voltage signals as well as signals from various thermoresistances and thermocouples. The device software allows programming display range, alarm value and type, and various nonlinear input-to-display transformations. Besides the relay alarm outputs, the indicator may be equipped with a digital interface and an analog retransmission output. The low price and the rich set of functions make TC600 widely applicable in industry and especially in power plants.
Technical specifications Input
Power supply
Pt50…1000 (w=1.385, 1.391) Cu50, Cu100 (w=1.426, 1.428) Other RTD (1) Thermocouple "J" Thermocouple "K" Thermocouple "S" Other thermocouple (1) Linear voltage 0…10 V Linear current 0(4)…20 mA Custom linear voltage; max. 40 V (1) Custom linear current; max. 50 mA (1) Decimal point selection Digital-display range Bargraph range Nonlinear transformation
-99.9(-200)...199.9(800) °C -50.0...199.9 °C min. -200...max. 1000 °C -100...900 °C 0...1200 °C 0...1600 °C min. -200...max. 2400 °C -1999...9999 (2) -1999...9999 (2) min. -1999...max. 9999 (2) min. -1999...max. 9999 (2) programmable programmable programmable up to 6 conversion modules (up to 2 relay and 1 analog) 5A/250V with NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA programmable 4(0)...20 mA or 0...10 V, isolated RS232 or RS485, isolated
Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Alarm set point Analog retransmission output Serial interface (3)
Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption
Indication and controls Digital display Bargraph display (4) LEDs Keyboard
Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digit height [mm] Bargraph shape Maximum weight [g] Protection, front/terminals Case material Wiring
0.4% from span 0.01% from span for 1 °C hardware, ± 1 °C
Custom; specify range within the limits stated Provides loop supply voltage - 24 VDC (only w/ isolated power supply)
Ordering code
-10...65 °C 0...85 %RH
Ambient temperature Ambient humidity
(3) (4)
'B'
'D'
96x96 panel 90x90 98 9 240° arc 650 IP54 / IP20 plastic plug-in terminals
144x72 panel 136x66 92 14 horizontal bar 650 IP54 / IP20 plastic plug-in terminals
Ask for availability! Custom display or/and scale design is also available. Ask!
TC600 - G0.G1.G5G5.G6'6".G9'9".G11 - #1
Code Feature or option
Code values
Case (front size)
B - 96x96 mm, D - 144x72 mm
G1
Power supply
A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
G5
Relay output
X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate
G6'
Input signal
B - thermoresistance, C - thermocouple, D - linear, Z - other on request
G0
G6"
Sensor
RTD
B - Pt50, D - Pt100, F - Pt500, G - Pt1000, H - Cu50, K - Cu100, Z - other (1)
T/C
J - "J", K - "K", S - "S", Z - other (1)
linear
B - 0…20 mA, C - 4…20 mA, K - 0…10 V, Z - other (1)
G9'
Serial interface
X - none, A - RS232 (3), B - RS485 (3)
G9"
Protocol
A - ASCII, C - ASCII for "PolyMonitor"
G11
Analog retransmission output
X - none, E - 0…20 mA, F - 4…20 mA, K - 0…10 V
#1
Nonlinear trans formation
X - none, HC - horizontal cylinder, LC - lying cylindrical tank, SC - standing cylindrical tank, SN - standing conical tank, SP - spherical tank, QR - square root, Z - other
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(1) (2)
4 LED indicators 50 LED dots 2 LEDs for output state 4 membrane keys
Operating conditions
Accuracy Measurement error Temperature drift Cold junction compensation
230 VAC or 115 VAC 90…250 V 12…24 V or 24 VAC 12…24 V max. 5 VA
process indicators Programmable Bargraph Indicator TC600 ♦ ♦ ♦ ♦ ♦ ♦
4-digit LED display plus 50-dot bargraph Various input signals and nonlinearities Programmable ranges and alarms Programmable relay and linear outputs Serial interface available Self-testing and self-calibration
TC600 is a microprocessor-based programmable process indicator with alarm relay outputs. In addition to the digital display, indicating the measured value, the device features a 50-dot LED bar-graph, showing the input value as a percentage of the input range. A changeable front-panel tag indicates the measurement unit. TC600 accepts standard current or voltage signals as well as signals from various thermoresistances and thermocouples. The device software allows programming display range, alarm value and type, and various nonlinear input-to-display transformations. Besides the relay alarm outputs, the indicator may be equipped with a digital interface and an analog retransmission output. The low price and the rich set of functions make TC600 widely applicable in industry and especially in power plants.
Technical specifications Input
Power supply
Pt50…1000 (w=1.385, 1.391) Cu50, Cu100 (w=1.426, 1.428) Other RTD (1) Thermocouple "J" Thermocouple "K" Thermocouple "S" Other thermocouple (1) Linear voltage 0…10 V Linear current 0(4)…20 mA Custom linear voltage; max. 40 V (1) Custom linear current; max. 50 mA (1) Decimal point selection Digital-display range Bargraph range Nonlinear transformation
-99.9(-200)...199.9(800) °C -50.0...199.9 °C min. -200...max. 1000 °C -100...900 °C 0...1200 °C 0...1600 °C min. -200...max. 2400 °C -1999...9999 (2) -1999...9999 (2) min. -1999...max. 9999 (2) min. -1999...max. 9999 (2) programmable programmable programmable up to 6 conversion modules (up to 2 relay and 1 analog) 5A/250V with NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA programmable 4(0)...20 mA or 0...10 V, isolated RS232 or RS485, isolated
Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Alarm set point Analog retransmission output Serial interface (3)
Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption
Indication and controls Digital display Bargraph display (4) LEDs Keyboard
Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digit height [mm] Bargraph shape Maximum weight [g] Protection, front/terminals Case material Wiring
0.4% from span 0.01% from span for 1 °C hardware, ± 1 °C
Custom; specify range within the limits stated Provides loop supply voltage - 24 VDC (only w/ isolated power supply)
Ordering code
-10...65 °C 0...85 %RH
Ambient temperature Ambient humidity
(3) (4)
'B'
'D'
96x96 panel 90x90 98 9 240° arc 650 IP54 / IP20 plastic plug-in terminals
144x72 panel 136x66 92 14 horizontal bar 650 IP54 / IP20 plastic plug-in terminals
Ask for availability! Custom display or/and scale design is also available. Ask!
TC600 - G0.G1.G5G5.G6'6".G9'9".G11 - #1
Code Feature or option
Code values
G0
Case (front size)
B - 96x96 mm, D - 144x72 mm
G1
Power supply
A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
G5
Relay output
X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate
G6'
Input signal
G6"
Sensor
B - thermoresistance, C - thermocouple, D - linear, Z - other on request RTD
B - Pt50, D - Pt100, F - Pt500, G - Pt1000, H - Cu50, K - Cu100, Z - other (1)
T/C
J - "J", K - "K", S - "S", Z - other (1)
linear
B - 0…20 mA, C - 4…20 mA, K - 0…10 V, Z - other (1)
G9'
Serial interface
X - none, A - RS232 (3), B - RS485 (3)
G9"
Protocol
A - ASCII, C - ASCII for "PolyMonitor"
G11
Analog retransmission output
X - none, E - 0…20 mA, F - 4…20 mA, K - 0…10 V
#1
Nonlinear transformation
X - none, HC - horizontal cylinder, LC - lying cylindrical tank, SC - standing cylindrical tank, SN - standing conical tank, SP - spherical tank, QR - square root, Z - other
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
COMECO reserves the right of changing specifications without prior notice!
(1) (2)
4 LED indicators 50 LED dots 2 LEDs for output state 4 membrane keys
Operating conditions
Accuracy Measurement error Temperature drift Cold junction compensation
230 VAC or 115 VAC 90…250 V 12…24 V or 24 VAC 12…24 V max. 5 VA
process indicators Loop-powered Indicator TI200 ♦ ♦ ♦ ♦ ♦ ♦ ♦
Panel, in-head, or free mounting IP65 box and Ex housing available 4-digit LCD or LED display Down to 2 mA operating loop current Programmable display ranges and alarms 2 alarm outputs Built-in temperature transmitter available
TI200 is a microprocessor-based programmable process indicator, designed especially to be powered from the input current loop. TI200 is equipped with a fully programmable -1999...9999 LCD or LED display with programmable point position and digital filter as well as with a 2-key (hidden) keyboard. Two alarm limits with programmable parameters – set point, hysteresis, direction, dead time, etc – control 2 alarm outputs (polarized relay type or open collector type, which can be used to control external relays). Five different housing types are available: − plastic case for panel mounting with 96x96 mm DIN front size; − plastic case for panel mounting with 96x48 mm DIN front size; − plastic box with IP65 protection class and 80x80 mm front size; − housing for mounting into sensor protection head type "DW" or "DHW"; − housing for mounting into sensor protection head type "EGW". The IP65-box housing allows a standard in-head transmitter to be incorporated inside the box so TI200 can be used as a temperature or level transmitter with local programmable display. The low price, alarm features, and flexibility make TI200 widely applicable in industry and especially when loop current transmission is measured.
Technical specifications Input
Indication and controls
Input type Operating range Measurement range Display range Display-to-input correspondence Decimal point selection
Outputs Non-isolated transistor gate Polarized relay Control algorithm Alarms
loop supply DC current 3...22 mA 4...20 mA min. -1999...max. 9999 programmable programmable (set of 2 alarm outputs) open collector, 100mA/40V 5A/250V w/ NO contact ON/OFF programmable
Accuracy ± 0.05% from span ± 1 digit within measurement error 0.025% from span for 1 °C
Measurement error Non-linearity Temperature drift
Power supply 4...36 VDC 2...50 mA
Loop supply voltage Loop supply current
4 LCD (plus backlight), 13 mm or 4 LED indicators, 14 mm 2 (hidden) keys
Digital display Keyboard
Operating conditions -10...65 °C 0...85 %RH (1)
Operating temperature Operating humidity
Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals)
'B'
'H'
'Y'
'Z1'
'Z2'
96x96 96x48 80x80 ø63 ø73 panel panel free (2) in head (3) in head 90x90 90x42 98 23 60 98 23 200 60 200 300 60 IP65 IP65 IP54/20 IP54/20 IP68 (4) IP65 IP65 plastic plastic plastic aluminum aluminum spring plug-in plug-in screw spring
(1)
0...95 %RH for case 'Y' Radial, axial, and DIN-rail mounting accessories for 80x80x60 mm box can be ordered separately (see 'Accessories') May be mounted in different, separately ordered Ex housings for field applications (see 'Accessories') (4) Ask for availability! (2)
Ordering code
TI200 - G0.G2.G5 - #1.#2.#3
Code Feature or option
Code values
G0
Case
B - for panel mounting, 96x96 mm, H - for panel mounting, 96x48 mm, Y - box IP65, Z1 - for mounting in head type "DW" or "DHW" (3), Z2 - for mounting in head type "EGW" (3)
G2
Display
A - LCD, B - LED, T - LCD + backlight
G5
Relay outputs (set of 2 alarm outputs)
X - none, A - relays NO, E - open collectors NPN, F - open collectors PNP
#1
Increased front protection
X - none, P - IP65 front protection (5)
#2
Temperature transmitter
X - none, TT - built-in temperature transmitter (6)
#3
Mounting kit
X - none, E - kit for mounting in Ex housing (7)
(5)
Not available for cases 'Y', 'Z1', and 'Z2'. Ask for case 'B'! Available ONLY for case 'Y'! Specify exact transmitter type and specifications separately. (7) Only for cases 'Z1' (for mounting in instrument housing EX) and 'Z2' (for mounting in head type "EGW") (6)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(3)
process indicators Loop-powered Indicator TI200 ♦ ♦ ♦ ♦ ♦ ♦ ♦
Panel, in-head, or free mounting IP65 box and Ex housing available 4-digit LCD or LED display Down to 2 mA operating loop current Programmable display ranges and alarms 2 alarm outputs Built-in temperature transmitter available
TI200 is a microprocessor-based programmable process indicator, designed especially to be powered from the input current loop. TI200 is equipped with a fully programmable -1999...9999 LCD or LED display with programmable point position and digital filter as well as with a 2-key (hidden) keyboard. Two alarm limits with programmable parameters – set point, hysteresis, direction, dead time, etc – control 2 alarm outputs (polarized relay type or open collector type, which can be used to control external relays). Five different housing types are available: − plastic case for panel mounting with 96x96 mm DIN front size; − plastic case for panel mounting with 96x48 mm DIN front size; − plastic box with IP65 protection class and 80x80 mm front size; − housing for mounting into sensor protection head type "DW" or "DHW"; − housing for mounting into sensor protection head type "EGW". The IP65-box housing allows a standard in-head transmitter to be incorporated inside the box so TI200 can be used as a temperature or level transmitter with local programmable display. The low price, alarm features, and flexibility make TI200 widely applicable in industry and especially when loop current transmission is measured.
Technical specifications Input
Indication and controls
Input type Operating range Measurement range Display range Display-to-input correspondence Decimal point selection
Outputs Non-isolated transistor gate Polarized relay Control algorithm Alarms
loop supply DC current 3...22 mA 4...20 mA min. -1999...max. 9999 programmable programmable (set of 2 alarm outputs) open collector, 100mA/40V 5A/250V w/ NO contact ON/OFF programmable
Accuracy ± 0.05% from span ± 1 digit within measurement error 0.025% from span for 1 °C
Measurement error Non-linearity Temperature drift
Power supply 4...36 VDC 2...50 mA
Loop supply voltage Loop supply current
4 LCD (plus backlight), 13 mm or 4 LED indicators, 14 mm 2 (hidden) keys
Digital display Keyboard
Operating conditions -10...65 °C 0...85 %RH (1)
Operating temperature Operating humidity
Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals)
'B'
'H'
'Y'
'Z1'
'Z2'
96x96 96x48 80x80 ø63 ø73 panel panel free (2) in head (3) in head 90x90 90x42 98 23 60 98 23 200 60 200 300 60 IP65 IP65 IP54/20 IP54/20 IP68 (4) IP65 IP65 plastic plastic plastic aluminum aluminum spring plug-in plug-in screw spring
(1)
0...95 %RH for case 'Y' Radial, axial, and DIN-rail mounting accessories for 80x80x60 mm box can be ordered separately (see 'Accessories') May be mounted in different, separately ordered Ex housings for field applications (see 'Accessories') (4) Ask for availability! (2)
Ordering code
TI200 - G0.G2.G5 - #1.#2.#3
Code Feature or option
Code values
G0
Case
B - for panel mounting, 96x96 mm, H - for panel mounting, 96x48 mm, Y - box IP65, Z1 - for mounting in head type "DW" or "DHW" (3), Z2 - for mounting in head type "EGW" (3)
G2
Display
A - LCD, B - LED, T - LCD + backlight
G5
Relay outputs (set of 2 alarm outputs)
X - none, A - relays NO, E - open collectors NPN, F - open collectors PNP
#1
Increased front protection
X - none, P - IP65 front protection (5)
#2
Temperature transmitter
X - none, TT - built-in temperature transmitter (6)
#3
Mounting kit
X - none, E - kit for mounting in Ex housing (7)
(5)
Not available for cases 'Y', 'Z1', and 'Z2'. Ask for case 'B'! Available ONLY for case 'Y'! Specify exact transmitter type and specifications separately. (7) Only for cases 'Z1' (for mounting in instrument housing EX) and 'Z2' (for mounting in head type "EGW") (6)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(3)
process indicators Loop-powered Indicator TI200 ♦ ♦ ♦ ♦ ♦ ♦ ♦
Panel, in-head, or free mounting IP65 box and Ex housing available 4-digit LCD or LED display Down to 2 mA operating loop current Programmable display ranges and alarms 2 alarm outputs Built-in temperature transmitter available
TI200 is a microprocessor-based programmable process indicator, designed especially to be powered from the input current loop. TI200 is equipped with a fully programmable -1999...9999 LCD or LED display with programmable point position and digital filter as well as with a 2-key (hidden) keyboard. Two alarm limits with programmable parameters – set point, hysteresis, direction, dead time, etc – control 2 alarm outputs (polarized relay type or open collector type, which can be used to control external relays). Five different housing types are available: − plastic case for panel mounting with 96x96 mm DIN front size; − plastic case for panel mounting with 96x48 mm DIN front size; − plastic box with IP65 protection class and 80x80 mm front size; − housing for mounting into sensor protection head type "DW" or "DHW"; − housing for mounting into sensor protection head type "EGW". The IP65-box housing allows a standard in-head transmitter to be incorporated inside the box so TI200 can be used as a temperature or level transmitter with local programmable display. The low price, alarm features, and flexibility make TI200 widely applicable in industry and especially when loop current transmission is measured.
Technical specifications Input
Indication and controls
Input type Operating range Measurement range Display range Display-to-input correspondence Decimal point selection
Outputs Non-isolated transistor gate Polarized relay Control algorithm Alarms
loop supply DC current 3...22 mA 4...20 mA min. -1999...max. 9999 programmable programmable (set of 2 alarm outputs) open collector, 100mA/40V 5A/250V w/ NO contact ON/OFF programmable
Accuracy ± 0.05% from span ± 1 digit within measurement error 0.025% from span for 1 °C
Measurement error Non-linearity Temperature drift
Power supply 4...36 VDC 2...50 mA
Loop supply voltage Loop supply current
4 LCD (plus backlight), 13 mm or 4 LED indicators, 14 mm 2 (hidden) keys
Digital display Keyboard
Operating conditions -10...65 °C 0...85 %RH (1)
Operating temperature Operating humidity
Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals)
'B'
'H'
'Y'
'Z1'
'Z2'
96x96 96x48 80x80 ø63 ø73 panel panel free (2) in head (3) in head 90x90 90x42 98 23 60 98 23 200 60 200 300 60 IP65 IP65 IP54/20 IP54/20 IP68 (4) IP65 IP65 plastic plastic plastic aluminum aluminum spring plug-in plug-in screw spring
(1)
0...95 %RH for case 'Y' Radial, axial, and DIN-rail mounting accessories for 80x80x60 mm box can be ordered separately (see 'Accessories') May be mounted in different, separately ordered Ex housings for field applications (see 'Accessories') (4) Ask for availability! (2)
Ordering code
TI200 - G0.G2.G5 - #1.#2.#3
Code Feature or option
Code values
G0
Case
B - for panel mounting, 96x96 mm, H - for panel mounting, 96x48 mm, Y - box IP65, Z1 - for mounting in head type "DW" or "DHW" (3), Z2 - for mounting in head type "EGW" (3)
G2
Display
A - LCD, B - LED, T - LCD + backlight
G5
Relay outputs (set of 2 alarm outputs)
X - none, A - relays NO, E - open collectors NPN, F - open collectors PNP
#1
Increased front protection
X - none, P - IP65 front protection (5)
#2
Temperature transmitter
X - none, TT - built-in temperature transmitter (6)
#3
Mounting kit
X - none, E - kit for mounting in Ex housing (7)
(5)
Not available for cases 'Y', 'Z1', and 'Z2'. Ask for case 'B'! Available ONLY for case 'Y'! Specify exact transmitter type and specifications separately. (7) Only for cases 'Z1' (for mounting in instrument housing EX) and 'Z2' (for mounting in head type "EGW") (6)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(3)
process indicators Battery-Powered Thermometer TIB100 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
Operates with TSEC temperature probes Direct in-process mounting All stainless steel design 4-digit 18 mm LCD display Captures minimum and maximum readings Powered by 2 AA batteries 20000 hours average battery life Programmable display ranges and alarms User calibration available Selectable temperature units
COMECO's TIB100 is a digital temperature indicator, designed for direct control over temperature processes when coupled with a TSEC or other compatible temperature probe. This model combines the power supply independence of the bimetallic/gas thermometers and the advantages of the digital temperature measuring instruments. TIB100 is a programmable device and allows current, minimum, and maximum temperature readings, alarm settings, unit selection, and user calibration.
Technical specifications Input
Power supply Pt100 (1), Pt500 (1), Pt1000 min. -50.0...max. 600 °C (min. -58.0...max. 1112.0 °F)
Input (sensor) type Measurement range
Accuracy Display measurement error Non-linearity Hysteresis Repeatability Temperature drift
≤ ± 0.3% of span within measurement error within measurement error within measurement error 0.005% from span for 1 °C
Indication and controls 4-digit LCD, 18 mm 0.1 or 1 °C, programmable on/off, °C/°F/K, min/max, auto off 3 membrane keys through the keyboard 2 programmable alarms on display
Digital display Display resolution Display functions Keyboard Device calibration Alarms
Supply voltage Battery life Battery state control Auto-power-off time
3 V from 2 batteries AA 1.5 V up to 20000 h (2) automatic 0...100 min, programmable
Operating conditions -10...50 °C 0...85 %RH
Ambient temperature Ambient humidity
Design and materials Case material Mounting Probe connection Dimensions Weight Protection class
stainless steel on probe top (3) G3/8", 3/8" NPT, G1/2", 1/2" NPT, M16x1.5, M18x1.5, or welding (4) axial: approx. ø100x50 mm; radial: approx. 100x120x35 mm max. 700 g IP65 (NEMA 4X)
(1)
Ask for availability! Depending on battery type, sensor, and operating mode Order separately! Suitable for assembly are temperature probes type TSEC (see 'Temperature Probes'). (4) Available only when an axial mounted probe is ordered. (2)
(3)
TIB100 - G1.G6'6".G12'12"
Code Feature or option
(5)
Code values
G1
Power supply
X - none (5), G - long-life batteries
G6'6"
Input
BD - Pt100 (1), BF - Pt500 (1), BG - Pt1000
G12'
Probe connection
Q0 - M16x1.5, Q1 - M18x1.5, Q3 - G3/8", Q4 - G1/2", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Uxx - female thread (xx - same as for Qxx), W - welding (4), Z - other (specify!)
G12"
Probe position
A - axial, R - radial underneath, RU - radial on top, RL - radial on the left, RR - radial on the right
The device is supplied without batteries.
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
process controllers Temperature Controller TC48 ♦ ♦ ♦ ♦ ♦ ♦
Low price 48x48 DIN-sized front panel Thermocouple or Pt100 RTD input Independent set-point observation Sensor break indication Panel, DIN-rail, and in-socket mounting
The TC48 temperature controller has no temperature value indication and thus is applicable in cases, in which the low price is one of the major requirements, especially in food industry and household applications. With its 48x48 mm DIN-sized front panel, TC48 is best suited for applications, in which small size is important too. The device works with either an RTD temperature sensor or a thermocouple type "J" or "K" and can be used for controlling various temperature processes and driving electrical actuators by the means of a relay control output and through ON/OFF algorithm. A potentiometer and a dial on the front panel enable easy set-point adjustment, and a red LED – a clear sensor break indication. The controller can be mounted on a panel, on a rail, and in a socket. Inexpensive, compact, and easy-to-use, the TC48 temperature controller is one versatile general-purpose control device.
Technical specifications Input
Indication and controls 0...100 °C, 0...200 °C, 0...400 °C (1) 0...100 °C, 0...200 °C, 0...400 °C, 0...800 °C (1) 0...400 °C, 0...800 °C, 0...1000 °C, 0...1200 °C (1)
Pt100 (w=1.385); 3-wire Thermocouple "J" Thermocouple "K"
LEDs Front-panel potentiometer Front-panel trimmer potentiometer
LED for relay state, LED for sensor break for set-point adjustment for hysteresis adjustment
Output Relay electromechanical Solid state relay (2) MOS gate (2) Output for external SSR Control algorithm Set point
5A/250V w/ NO/NC or NO contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF within input range limits
Accuracy Measurement error Temperature drift Cold junction compensation
0.5% from span 0.007% from span for 1 °C ± 1 °C
Power supply 230 VAC or 115 VAC 24 VAC max. 3 VA
Mains supply voltage Isolated low voltage (2) Consumption (2) (3)
-10...65 °C 0...85 %RH
Operating temperature Operating humidity
Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals
plastic in 45x45 mm panel cut-out or on 35 mm DIN rail socket (3) OCTAL or UNDECAL 48x48(front)x95 mm 103 mm (w/ socket) max. 250 g IP40 / IP20
Specify range when ordering. Ask for availability! Ordered separately (see 'Accessories')
Ordering code
TC48 - G1.G5.G6'6"
Code Feature or option
Code values
G1
Power supply
A - 230 VAC, B - 115 VAC, R - 24 VAC (2)
G5
Relay output
X - none, C - relay NO/NC, D - SSR (2), J - for external SSR, M - isolated MOS gate (2)
G6'6"
Input
(1)
BD - Pt100, CJ - thermocouple "J", CK - thermocouple "K"
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(1)
Operating conditions
process controllers All-purpose Analog Controller TC56 ♦ ♦ ♦ ♦
Very good EMI protection User-friendly controls Analog retransmission output 4-digit LED display
TC56 is an electronic analog controller with very good protection against electromagnetic disturbances, used for automatic control of various processes through relay outputs employing ON/OFF control algorithm. The device can operate with a number of input signal types – thermoresistive, thermoelectrical, or standard signals from relative humidity, pressure, flow, etc. transmitters – at that providing supply for input signal transmitters. In addition to the 2 control or alarm relay outputs, the TC56 controller can be equipped with an analog retransmission output that generates standard signal to external chart recorders, controllers, and indicators.
Technical specifications Input
Accuracy
Pt46 (GOST) Pt50 (w=1.385, 1.391) Pt100 (w=1.385, 1.391) Pt500 (w=1.385) Pt1000 (w=1.385) Cu100 (w=1.426, 1.428) Cu50 (w=1.426, 1.428) Cu53 (GOST) Other RTD (1) Thermocouple "J" Thermocouple "K" Linear voltage 0…1/ 2 / 5/ 10 V Linear current 0…5 mA Linear current 0(4)…20 mA Custom linear voltage; max. 10 V Custom linear current; max. 50 mA
-50...199.9(600) °C -50...199.9(600) °C -50...199.9(600) °C -50...199.9(600) °C -50...199.9(600) °C -50...199.9(200) °C -50...199.9(200) °C -50...199.9(200) °C min. -99...max. 600 °C 0...700 °C 0...700(1200) °C -199.9(1999)...199.9(1999) (2,3) -199.9(1999)...199.9(1999) (2,3) -199.9(1999)...199.9(1999) (2,3) min. -1999...max. 1999 (2,3) min. -1999...max. 1999 (2,3) (up to 3 outputs) 5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF within input range limits 2 control or 1 control and 1 alarm 0(4)...20 mA or 0...10 V none
Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Relay function Analog retransmission output Isolation
0.5% from span 0.007% from span for 1 °C automatic hardware, ± 1 °C
Measurement error Temperature drift Cold junction compensation
Power supply 230 VAC or 115 VAC 24 VAC max. 4 VA
Mains supply voltage Isolated low voltage Consumption
Indication and controls Digital display LEDs Multi-turn potentiometer Front-panel trimmer Case-side trimmers
4 LED indicators, 14 mm 2 LEDs for relay-output state for set-point adjustment (4) for hysteresis and dead-band adjustment for alarm-limit adjustment
Operating conditions -10...65 °C 0...85 %RH
Operating temperature Operating humidity
Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals
plastic on 90x42 mm panel cut-out plug-in terminals 96x48(front)x107 mm 98 mm max. 400 g IP40 / IP20
(1)
Custom; specify range within the limits stated Specify lower and upper display limits Provides loop supply voltage - 24 VDC (4) Displayed while the set-point button is pressed (2) (3)
TC56 - G1.G3.G5G5.G6'6".G10.G11
Code Feature or option
Code values
G1
Power supply
A - 230 VAC, B - 115 VAC, R - 24 VAC
G3
Resolution
B - 1, C - 0.1
G5
Relay output
X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate
G6'
Input signal
B - thermoresistance, C - thermocouple, D - linear A - Pt46, B - Pt50, C - Pt50, D - Pt100, E - Pt100, F - Pt500, G - Pt1000, H - Cu50, I - Cu50, J - Cu53, K - Cu100, L - Cu100, Z - other (1)
RTD G6"
Sensor
T/C linear
J - "J", K - "K" (2)
A - 0...5 mA, B - 0...20 mA, C - 4...20 mA, H - 0...1 V, I - 0...2 V, J - 0...5 V, K - 0...10 V, Z - other
G10
Alarm
X - none, A - absolute upper, B - absolute lower, C - absolute mixed, D - relative above set point, E - relative below set point
G11
Analog retransmission output
X - none, E - 0…20 mA, F - 4…20 mA, K - 0…10 V, Z - other
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
process controllers Programmable Controller RT28U ♦ ♦ ♦ ♦ ♦ ♦
Low cost 3-digit bright LED display 4 DIN cases Universal input for 4 RTDs, 6 T/Cs, and 4 linear types Keyboard or encoder adjustment controls RS485 serial interface available
RT28U is designed for wide range of applications. It is equipped with a 3-digit LED display, a universal input for Pt100, Pt1000, PTC, 6 thermocouple types as well as for linear current, voltage, and resistive signals from external transmitters and can have up to 2 programmable relay control/alarm outputs. RT28U can be ordered with either keyboard, or unique rotating encoder for set-point adjustment and programming. All modifications have a built-in circuit for self-testing and self-calibration, manual measurement offset setting, and automatic software compensation of line resistance and cold junction temperature. The display-toinput correspondence (in case of linear input), decimal point position, temperature measurement unit, and offset value are also programmable. Thanks to its universal input, the available various enclosures, serial interface, and excellent price-to-performance ratio, RT28U is an exceptionally widely applicable device.
Technical specifications (programmable)
Pt100 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire PTC (1k at 25 °C); 3-wire PTC (2k at 25 °C); 3-wire Thermocouple "T" Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" Linear voltage 0...10 V Linear current 0(4)...20 mA Linear resistive 0...1 kΩ Custom linear (option) (1) Two-wire external transmitter Manual input offset Input type selection Decimal point selection Temperature measurement unit
Outputs
-100...850 °C -100...600 °C -50...150 °C -50...150 °C -40...400 °C -20...999 °C -20...999 °C 0...999 °C 0...999 °C 100...999 °C -199...999, programmable -199...999, programmable -199...999, programmable -199...999, programmable 4...20 mA (2) programmable programmable programmable °C or °F, programmable (up to 2 relay outputs)
Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Alarms Serial interface
5A/250V w/ NO/NC or NO (3) contact 1A/250VAC (4) 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF within input range limits programmable RS485, isolated
(1)
Instead of linear current Provides loop supply voltage - 24 VDC (only w/ isolated power supply). (3) For case 'S' w/ SMPS, 1st relay is NO; for case 'L' and case 'S' w/ serial interface, 2nd relay is NO. (4) 0.2A/250VAC for case 'L' (5) 0.5% for T/Cs "S", "R", and "B" (2)
Ordering code
Accuracy 0.3% (5) from span 0.02% from span for 1 °C automatic, -10...80 °C automatic, up to 2 х 25 Ω
Measurement error Temperature drift Cold junction compensation RTD line compensation
Power supply Mains supply voltage (6) SMPS voltage Isolated low voltage Non-isolated low voltage External mains transformer (7) Consumption
230 VAC or 115 VAC 90…250 V 12…24 V or 24 VAC 12…24 V 9(12) VAC max. 1.5 VA
Indication and controls Digital display LEDs Controls
3 LED indicators 2 LEDs for output state keyboard w/ 3 keys or rotary encoder (8)
Operating conditions Ambient temperature Ambient humidity
Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals)
'B' 96x96 panel 90x90 98 20 350 IP54/20 IP65 (9) plastic plug-in
'H' / 'V' 96x48 panel 90x42 98 14 300 IP54/20 IP65 plastic plug-in
-10...65 °C 0...85 %RH 'S' 'L' 48x48 72x36 panel panel 45x45 71x29 56 100 14 10 150 200 IP54/20 IP54/20 IP65 plastic plastic screw screw
(6)
Not available for case 'L'. Ordered separately (see 'Accessories') Available ONLY for cases 'H', 'V', and 'B'. (9) Ask for availability! (10) Not available for case 'S'. (7)
(8)
RT28U - G0.G1.G4.G5G5.G9'9" - #1.#2
Code Feature or option
Code values
G0
Case (front size)
B - 96x96 mm, H - 96x48 mm, V - 48x96 mm, S - 48x48 mm, L - 72x36 mm
G1
Power supply
A - 230 VAC (6), B - 115 VAC (6), C - 90…250 V, E - 9(12) VAC w/ external transformer (7), P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
G4
Adjustment controls
A - keyboard, H - rotary encoder (8)
G5
Relay output
X - none, A - relay NO (3), C - relay NO/NC (3), D - SSR, J - for external SSR, M - isolated MOS gate
G9'
Serial interface
X - none, B - RS485
G9"
Protocol
A - ASCII, C - ASCII for "PolyMonitor"
#1
Increased front protection
X - none, P - IP65 front protection (10)
#2
Customer specified input signal
X - none, Z - custom linear signal (specify!) (1)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
COMECO reserves the right of changing specifications without prior notice!
Input
process controllers Programmable Controller RT28U-R ♦ ♦ ♦ ♦ ♦
Low cost DIN-rail case and 11-pin box for rail mounting 3-digit bright LED display Universal input for 4 RTDs, 6 T/Cs, and 4 linear types RS485 serial interface available
RT28U-R is a modification of RT28U for rail mounting. It is equipped with a 3-digit LED display, a universal input for Pt100, Pt1000, PTC, 6 thermocouple types as well as for linear current, voltage, and resistive signals from external transmitters and can have up to 2 programmable relay control/alarm outputs. The device has a built-in circuit for self-testing and self-calibration, manual measurement offset setting, and automatic software compensation of line resistance and cold junction temperature. The display-to-input correspondence (in case of linear input), decimal point position, temperature measurement unit, and offset value are also programmable. Thanks to its universal input, serial interface, and excellent price-to-performance ratio, RT28U-R is a widely applicable device.
Technical specifications Input Pt100 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire PTC (1k at 25 °C); 3-wire PTC (2k at 25 °C); 3-wire Thermocouple "T" Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" Linear voltage 0...10 V Linear current 0(4)...20 mA Linear resistive 0...1 kΩ Custom linear (option) (1) Two-wire external transmitter Manual input offset Input type selection Decimal point selection Temperature measurement unit
Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Alarms Serial interface (4)
(programmable) -100...850 °C -100...600 °C -50...150 °C -50...150 °C -40...400 °C -20...999 °C -20...999 °C 0...999 °C 0...999 °C 100...999 °C -199...999, programmable -199...999, programmable -199...999, programmable -199...999, programmable 4...20 mA (2) programmable programmable programmable °C or °F, programmable (up to 2 relay outputs) 5A/250V w/ NO/NC or NO (3) contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF within input range limits programmable RS485, isolated
Accuracy 0.3% (5) from span 0.02% from span for 1 °C automatic, -10...80 °C automatic, up to 2 х 25 Ω
Measurement error Temperature drift Cold junction compensation RTD line compensation
Power supply Mains supply voltage Isolated low voltage Non-isolated low voltage External mains transformer (6) Consumption
230 VAC or 115 VAC 12…24 V or 24 VAC 12…24 V 9(12) VAC max. 1.5 VA
Indication and controls 3 LED indicators 2 LEDs for output state 3 membrane keys
Digital display LEDs Keyboard
Operating conditions -10...65 °C 0...85 %RH
Ambient temperature Ambient humidity
Design and materials Dimensions [mm] Mounting Display digit height [mm] Maximum weight [g] Protection, front/terminals Case material Wiring
'R1'
'R2'
70x110x58 on rail 14 300 IP20 plastic screw terminals
35x78x91 in socket or on rail 10 200 IP44 / IP20 plastic socket UNDECAL (6)
(1)
Instead of linear current Provides loop supply voltage - 24 VDC (only w/ isolated power supply). NO/NC for case 'R1'; NO for case 'R2' (4) Not available for case 'R2'. (5) 0.5% for T/Cs "S", "R", and "B" (6) Ordered separately (see 'Accessories') (2)
Ordering code
RT28U - G0.G1.G5G5.G9'9" - #1
Code Feature or option
Code values
G0
Case
R1 - for rail mounting, R2 - 11-pin box
G1
Power supply
A - 230 VAC, B - 115 VAC, E - 9(12) VAC w/ external transformer (6), P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
G5
Relay output
X - none, A - relay NO (3), C - relay NO/NC (3), D - SSR, J - for external SSR, M - isolated MOS gate (4)
G9'
Serial interface
G9"
Protocol
A - ASCII, C - ASCII for "PolyMonitor"
#1
Customer specified input signal
X - none, Z - custom linear signal (specify!) (1)
X - none, B - RS485
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(3)
process controllers Programmable Controller RT28U-R ♦ ♦ ♦ ♦ ♦
Low cost DIN-rail case and 11-pin box for rail mounting 3-digit bright LED display Universal input for 4 RTDs, 6 T/Cs, and 4 linear types RS485 serial interface available
RT28U-R is a modification of RT28U for rail mounting. It is equipped with a 3-digit LED display, a universal input for Pt100, Pt1000, PTC, 6 thermocouple types as well as for linear current, voltage, and resistive signals from external transmitters and can have up to 2 programmable relay control/alarm outputs. The device has a built-in circuit for self-testing and self-calibration, manual measurement offset setting, and automatic software compensation of line resistance and cold junction temperature. The display-to-input correspondence (in case of linear input), decimal point position, temperature measurement unit, and offset value are also programmable. Thanks to its universal input, serial interface, and excellent price-to-performance ratio, RT28U-R is a widely applicable device.
Technical specifications Input Pt100 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire PTC (1k at 25 °C); 3-wire PTC (2k at 25 °C); 3-wire Thermocouple "T" Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" Linear voltage 0...10 V Linear current 0(4)...20 mA Linear resistive 0...1 kΩ Custom linear (option) (1) Two-wire external transmitter Manual input offset Input type selection Decimal point selection Temperature measurement unit
Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Alarms Serial interface (4)
(programmable) -100...850 °C -100...600 °C -50...150 °C -50...150 °C -40...400 °C -20...999 °C -20...999 °C 0...999 °C 0...999 °C 100...999 °C -199...999, programmable -199...999, programmable -199...999, programmable -199...999, programmable 4...20 mA (2) programmable programmable programmable °C or °F, programmable (up to 2 relay outputs) 5A/250V w/ NO/NC or NO (3) contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF within input range limits programmable RS485, isolated
Accuracy 0.3% (5) from span 0.02% from span for 1 °C automatic, -10...80 °C automatic, up to 2 х 25 Ω
Measurement error Temperature drift Cold junction compensation RTD line compensation
Power supply Mains supply voltage Isolated low voltage Non-isolated low voltage External mains transformer (6) Consumption
230 VAC or 115 VAC 12…24 V or 24 VAC 12…24 V 9(12) VAC max. 1.5 VA
Indication and controls 3 LED indicators 2 LEDs for output state 3 membrane keys
Digital display LEDs Keyboard
Operating conditions -10...65 °C 0...85 %RH
Ambient temperature Ambient humidity
Design and materials Dimensions [mm] Mounting Display digit height [mm] Maximum weight [g] Protection, front/terminals Case material Wiring
'R1'
'R2'
70x110x58 on rail 14 300 IP20 plastic screw terminals
35x78x91 in socket or on rail 10 200 IP44 / IP20 plastic socket UNDECAL (6)
(1)
Instead of linear current Provides loop supply voltage - 24 VDC (only w/ isolated power supply). NO/NC for case 'R1'; NO for case 'R2' (4) Not available for case 'R2'. (5) 0.5% for T/Cs "S", "R", and "B" (6) Ordered separately (see 'Accessories') (2)
Ordering code
RT28U - G0.G1.G5G5.G9'9" - #1
Code Feature or option
Code values
G0
Case
R1 - for rail mounting, R2 - 11-pin box
G1
Power supply
A - 230 VAC, B - 115 VAC, E - 9(12) VAC w/ external transformer (6), P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
G5
Relay output
X - none, A - relay NO (3), C - relay NO/NC (3), D - SSR, J - for external SSR, M - isolated MOS gate (4)
G9'
Serial interface
G9"
Protocol
A - ASCII, C - ASCII for "PolyMonitor"
#1
Customer specified input signal
X - none, Z - custom linear signal (specify!) (1)
X - none, B - RS485
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(3)
process controllers Programmable ON/OFF Controller RT38 ♦ ♦ ♦ ♦ ♦ ♦
Low cost 5 DIN cases - up to 1/32 DIN Low power consumption Semi-universal input Various power supplies Fully programmable parameters
The cheap programmable controller RT38 is designed for wide range of ON/OFF control applications. Equipped with a 3-digit LED display, RT38 is especially suitable for measuring and controlling various technological values with resolution of up to 1000 points. It can be ordered in various cases including the smallest 1/32 DIN case, and for different power supplies. The device has 1 programmable relay control/alarm output and is available in 2 universal-input versions: RTD - for 7 selectable Ptx and 4 Cux sensor types, and T/C - for 3 selectable thermocouples as well as versions for linear current and voltage signals. RT38 allows an automatic software compensation of line resistance and cold junction temperature. The display-to-input correspondence (in case of linear input), the decimal point position, the temperature measuring unit as well as the offset value are also programmable. Thanks to its power supply options, semi-universal input, and excellent price-to-performance ratio, RT38 is an exceptionally widely applicable device.
Technical specifications RTD, DIN (w=1.385); 3-wire RTD, GOST (w=1.391); 3-wire RTD measurement range Thermocouple "T" Thermocouple "J" Thermocouple "K" Linear voltage 0...10 V Linear current 0(4)...20 mA Two-wire external transmitter RTD or T/C type selection Decimal point selection Temperature measurement unit
(programmable) Pt50, Pt100, Pt500, Pt1000 Pt46, Pt50, Pt100, Cu50, Cu100 -100...600 °C -40...400 °C -20...999 °C -20...999 °C -199...999, programmable -199...999, programmable 4...20 mA (1) programmable programmable °C or °F, programmable
Output Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Alarms
5A/250V w/ NO/NC (2) contact 1A/250VAC (3) 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF within input range limits programmable
Accuracy Measurement error Temperature drift Cold junction compensation RTD line compensation
0.3% from span 0.02% from span for 1 °C automatic, -10...80 °C automatic, up to 2 х 25 Ω
Power supply
Indication and controls
Operating conditions Operating temperature Operating humidity
Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals) (5)
(2)
(6)
Ordering code
3 LED indicators LED for output state 2 or 3 membrane keys, lockable
Digital display LEDs Keyboard
(1)
Provides loop supply voltage - 24 VDC (only w/ isolated power supply) NO for case 'M' (3) 0.2A/250VAC for case 'M' (4) Not available for case 'M'
230 VAC (4) or 115 VAC (4) 90…250 VAC/DC (5) 12…24 VAC/DC or 24 VAC (4) 12…24 VAC/DC 9(12) VAC max. 1.5 VA
Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage External mains transformer (6) Consumption
'B'
'H' / 'V'
'S'
-10...65 °C 0...85 %RH 'L' 'M'
96x96 96x48 48x48 72x36 48x24 panel panel panel panel panel 90x90 90x42 45x45 71x29 46x22 98 56 98 100 42 14 14 20 10 9 250 150 300 200 30 IP54/20 IP54/20 IP54/20 IP54/20 IP54/20 IP65 IP65 IP65 (7) plastic plastic plastic plastic plastic plug-in plug-in screw screw screw
Not available for cases 'L' and 'M' Ordered separately (see 'Accessories') Ask for availability! (8) Not available for cases 'S' and 'M' (7)
RT38 - G0.G1.G5.G6 - #1
Code Feature or option
Code values
G0
Case (front size)
B - 96x96 mm, H - 96x48 mm, V - 48x96 mm, S - 48x48 mm, L - 72x36 mm, M - 48x24 mm
G1
Power supply
A - 230 VAC (4), B - 115 VAC (4), C - 90…250 V (5), E - 9(12) VAC w/ external transformer (6), P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC (4)
G5
Relay output
X - none, C - relay NO/NC (2), D - SSR, J - for external SSR, M - isolated MOS gate
G6
Input
B - RTD (programmable), C - thermocouple (programmable), D - 0(4)…20 mA, DK - 0…10 V
#1
Increased front protection
X - none, P - IP65 front protection (8)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Input
process controllers Programmable ON/OFF Controller RT38-R ♦ ♦ ♦ ♦ ♦ ♦
Low cost 11-pin box for DIN-rail mounting 3-digit bright LED display Semi-universal input Various power supplies Fully programmable parameters
Technical specifications Input RTD, DIN (w=1.385); 3-wire RTD, GOST (w=1.391); 3-wire RTD measurement range Thermocouple "T" Thermocouple "J" Thermocouple "K" Linear voltage 0...10 V Linear current 0(4)...20 mA Two-wire external transmitter RTD or T/C type selection Decimal point selection Temperature measurement unit
(programmable) Pt50, Pt100, Pt500, Pt1000 Pt46, Pt50, Pt100, Cu50, Cu100 -100...600 °C -40...400 °C -20...999 °C -20...999 °C -199...999, programmable -199...999, programmable 4...20 mA (1) programmable programmable °C or °F, programmable
Output 5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF within input range limits programmable
Accuracy 0.3% from span 0.02% from span for 1 °C
Measurement error Temperature drift (2)
Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage External mains transformer (2) Consumption
230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC 9(12) VAC max. 1.5 VA
Indication and controls Digital display LEDs Keyboard
3 LED indicators, 10 mm LED for output state 3 membrane keys, lockable
Operating conditions
Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Alarms
(1)
Power supply
-10...65 °C 0...85 %RH
Operating temperature Operating humidity
Design and materials Case material Mounting Wiring Dimensions Weight Protection, front/terminals
plastic in socket or on 35 mm DIN rail socket UNDECAL (2) 35x78x91 mm 180 g IP44 / IP20
Provides loop supply voltage - 24 VDC (only w/ isolated power supply) Ordered separately (see 'Accessories')
Ordering code
RT38 - R.G1.G5.G6
Code Feature or option
Code values
Power supply
G5
Relay output
X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate
G6
Input
B - RTD (programmable), C - thermocouple (programmable), D - 0(4)…20 mA, DK - 0…10 V
COMECO reserves the right of changing specifications without prior notice!
G1
A - 230 VAC, B - 115 VAC, C - 90…250 V, E - 9(12) VAC w/ external transformer (2), P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
process controllers Programmable Controller RT18 ♦ ♦ ♦ ♦ ♦
Self-tuning ON/OFF or PI control algorithm 4 DIN cases - up to 1/16 DIN Fixed input Various power supplies Easy programming
RT18 is a programmable temperature ON/OFF controller with fixed input for various temperature sensors and linear signals. It is equipped with 3-digit LED display and relay control output. For easy mounting in existing cutouts, RT18 is available with 48x48, 96x48, 48x96, and 96x96 mm front sizes. To control its output, the device may utilize either ON/OFF or PI auto-tune control algorithm, the latter being a convenient solution that saves installation time and costs and provides precise control. The reliable operation in noisy industrial environment also extends RT18 application area.
Technical specifications Input
(total number of points for any range: 999)
Pt50 (w=1.385); 3-wire Pt100 (w=1.385); 3-wire Pt500 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire Cu100; 3-wire Cu50; 3-wire Other RTD (1) Thermocouple "J" Thermocouple "K" Thermocouple "L" Thermocouple "L-GOST" Other thermocouple (1) Linear voltage 0...10 V Linear current 0(4)...20 mA Custom linear voltage; max. 40 V Custom linear current; max. 80 mA
-9.9(-50)...90.0(500) °C -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(200) °C -9.9(-50)...90.0(200) °C min. -99...max. 500 °C 0...999(600) °C (2) (2) 0...999(850) °C 0...900(600) °C (2) 0...650(550) °C (2) min. -99(0)...max. 900(999) °C (2) -99...900 (0...999) (2,3,4) (2,3,4) -99...900 (0...999) min. -99...max. 999 (2,3,4) min. -99...max. 999 (2,3,4)
Accuracy Measurement error Temperature drift Cold junction compensation RTD line compensation (option)
Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption
Operating conditions Operating temperature Operating humidity
Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Programmable parameters
Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals)
(1)
(4)
(2)
(5)
Provides loop supply voltage - 24 VDC (only w/ isolated power supply) Ask for availability!
Code values
G0
Case (front size)
B - 96x96 mm, H - 96x48 mm, V - 48x96 mm, S - 48x48 mm
G1
Power supply
A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
G3
Resolution
B - 1, C - 0.1 (2)
G5
Relay output
X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate
G6'
Input signal
G6"
(7)
'H' 96x48 panel 90x42 98 14 300 IP54/20 IP65 plastic plug-in
RT18 - G0.G1.G3.G5.G6'6".G8 - #1.#2
Code Feature or option
(6)
'B' 96x96 panel 90x90 98 20 350 IP54/20 (5) IP65 plastic plug-in
-10...65 °C 0...85 %RH 'V' 'S' 48x96 48x48 panel panel 42x90 45x45 98 100 14 10 300 200 IP54/20 IP54/20 IP65 plastic plastic plug-in screw
Sensor
B - thermoresistance, C - thermocouple, D - linear, Z - other on request RTD
B - Pt50, D - Pt100, F - Pt500, G - Pt1000, H - Cu50, K - Cu100, Z - other (1)
T/C
J - "J", K - "K", L - "L" , M - "L-GOST", Z - other (1)
linear
B - 0…20 mA (3), C - 4…20 mA (3), K - 0…10 V (3), Z - other (3) (6)
G8
Control algorithm
A - ON/OFF, C - self-tuning PI
#1
Compensation for 3-wire RTD line
X - none, LC - built-in line resistance compensation
#2
Increased front protection
X - none, P - IP65 front protection (7)
Specify the direction of control action (heating or cooling relay action). Not available for case 'S'!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
COMECO reserves the right of changing specifications without prior notice!
Ordering code
3 LED indicators LED for output state 3 membrane keys
Digital display LEDs Keyboard
Design and materials
Custom; specify range within the limits stated. For self-tuning PI algorithm, ONLY the alternative ranges are applicable. (3) Specify lower and upper display limits.
230 VAC or 115 VAC 90...250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 3 VA
Indication and controls
Output 5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF, self-tuning PI within input range limits according to control algorithm
0.4% from span 0.005% from span for 1 °C ± 1 °C 0.01% from span for 1 Ω
process controllers Programmable Controller RT28 ♦ ♦ ♦ ♦ ♦ ♦
2 output relays ON/OFF or PD-for-MV control algorithm 3 DIN cases Fixed input Various power supplies Easy programming
The simple-design low-cost microprocessor-based controller RT28 combines the advantages of the microprocessor devices with the high reliability of analog controllers. It is available with 96x48, 48x96, and 96x96 mm DIN-sized front panel and can be equipped with up to 2 control relays. To control its outputs, RT28 may utilize either ON/OFF (heat/cool) duplex or PD control algorithm. The ON/OFF control algorithm allows flexible programming of the action of each relay for solving variety of problems. The PD algorithm results in PI control when used to control motorized valve actuators without position feedback. The reliable operation even in the presence of electromagnetic disturbances and the attractive price also account for the success of the RT28 controller.
Technical specifications (total number of points for any range: 999) -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(200) °C -9.9(-50)...90.0(200) °C min. -99...max. 500 °C 0...999(600) °C 0...999(850) °C 0...900(600) °C 0...650(550) °C min. -99(0)...max. 900(999) °C -99...900 (0...999) (2,3) -99...900 (0...999) (2,3) min. -99...max. 999 (2,3) min. -99...max. 999 (2,3)
Pt50 (w=1.385); 3-wire Pt100 (w=1.385); 3-wire Pt500 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire Cu100; 3-wire Cu50; 3-wire Other RTD (1) Thermocouple "J" Thermocouple "K" Thermocouple "L" Thermocouple "L-GOST" Other thermocouple (1) Linear voltage 0...10 V Linear current 0(4)...20 mA Custom linear voltage; max. 40 V Custom linear current; max. 80 mA
Outputs
(up to 2 relay outputs)
Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Programmable parameters
5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF, PD within input range limits according to control algorithm
Accuracy
Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption
3 LED indicators 2 LED for output state 3 membrane keys
Digital display LEDs Keyboard
Operating conditions Ambient temperature Ambient humidity
Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals) (4)
(2)
(5)
Ordering code
230 VAC or 115 VAC 90...250 V 12…24 V or 24 VAC 12…24 V max. 3 VA
Indication and controls
(1)
Custom; specify range within the limits stated. Specify lower and upper display limits. (3) Provides loop supply voltage - 24 VDC (only w/ isolated power supply)
0.4% from span 0.005% from span for 1 °C ± 1 °C 0.01% from span for 1 Ω
Measurement error Temperature drift Cold junction compensation RTD line compensation (option)
'B' 'H' 96x96 96x48 panel panel 90x42 90x90 98 98 14 20 300 350 IP54 / IP20 IP54 / IP20 IP65 IP65 (4) plastic plastic plug-in plug-in
-10...65 °C 0...85 %RH 'V' 48x96 panel 42x90 98 14 300 IP54 / IP20 IP65 plastic plug-in
Ask for availability! Ordered separately (see 'Accessories')
RT28 - G0.G1.G3.G5G5.G6'6".G8 - #1.#2
Code Feature or option
Code values
G0
Case (front size)
B - 96x96 mm, H - 96x48 mm, V - 48x96 mm
G1
Power supply
A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
G3
Resolution
B - 1, C - 0.1
G5
Relay output
X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate
G6'
Input signal
G6"
Sensor
B - thermoresistance, C - thermocouple, D - linear, Z - other on request RTD
B - Pt50, D - Pt100, F - Pt500, G - Pt1000, H - Cu50, K - Cu100, Z - other (1)
T/C
J - "J", K - "K", L - "L" , M - "L-GOST", Z - other (1)
linear
B - 0…20 mA (2), C - 4…20 mA (2), K - 0…10 V (2), Z - other (2)
G8
Control algorithm
A - ON/OFF, D - PD
#1
Compensation for 3-wire RTD line
X - none, LC - built-in line resistance compensation
#2
Increased front protection
X - none, P - IP65 front protection
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
COMECO reserves the right of changing specifications without prior notice!
Input
process controllers Programmable Controller RT284U ♦ ♦ ♦ ♦ ♦ ♦
Low cost 4-digit bright LED display 5 DIN cases Universal input for 4 RTDs, 6 T/Cs, and 4 linear types Keyboard or encoder adjustment controls RS485 serial interface available
RT284U is designed for wide range of applications. It is equipped with a 4-digit LED display, a universal input for Pt100, Pt1000, PTC, 6 thermocouple types as well as for linear current, voltage, and resistive signals from external transmitters and can have up to 2 programmable relay control/alarm outputs. RT284U can be ordered with either keyboard or unique rotating encoder for set-point adjustment and programming. All modifications have a built-in circuit for self-testing and self-calibration, manual measurement offset setting, and automatic software compensation of line resistance and cold junction temperature. The display-to-input correspondence (in case of linear input), decimal point position, temperature measurement unit, and offset value are also programmable. Thanks to its universal input, the available various enclosures and serial interface as well as excellent price-to-performance ratio, RT284U is an exceptionally widely applicable device.
Technical specifications Accuracy
(programmable)
Pt100 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire PTC (1k at 25 °C); 3-wire PTC (2k at 25 °C); 3-wire Thermocouple "T" Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" Linear voltage 0...10 V Linear current 0(4)...20 mA Linear resistive 0...1 kΩ Custom linear (option) (1) Two-wire external transmitter Manual input offset Input type selection Decimal point selection Temperature measurement unit
Outputs
Power supply Mains supply voltage (6) SMPS voltage Isolated low voltage Non-isolated low voltage External mains transformer (7) Consumption
Operating conditions Ambient temperature Ambient humidity
Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals)
(1)
(6)
(2)
(7)
Ordering code
4 LED indicators 2 LEDs for output state keyboard w/ 3 keys or rotary encoder (8)
Digital display LEDs Controls
5A/250V w/ NO/NC or NO (3) contact 1A/250VAC (4) 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF within input range limits programmable RS485, isolated
Instead of linear current Provides loop supply voltage - 24 VDC (only w/ isolated power supply). (3) For case 'Q' and case 'S' w/ SMPS, 1st relay is NO; for case 'L', case 'Q' w/ SMPS, and case 'S' w/ serial interface, 2nd relay is NO. (4) 0.2A/250VAC for case 'L' (5) 0.5% for T/Cs "S", "R", and "B"
230 VAC or 115 VAC 90…250 V 12…24 V or 24 VAC 12…24 V 9(12) VAC max. 2 VA
Indication and controls
(up to 2 relay outputs)
Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Alarms Serial interface
0.3% (5) from span 0.02% from span for 1 °C automatic, -10...80 °C automatic, up to 2 х 25 Ω
Measurement error Temperature drift Cold junction compensation RTD line compensation
-100...850 °C -100...600 °C -50...150 °C -50...150 °C -40...400 °C -20...1000 °C -20...1300 °C 0...1700 °C 0...1700 °C 100...1800 °C -1999...9999, programmable -1999...9999, programmable -1999...9999, programmable -1999...9999, programmable 4...20 mA (2) programmable programmable programmable °C or °F, programmable
'B' 'H' / 'V' 'Q' 96x96 96x48 72x72 panel panel panel 90x90 90x42 67x67 98 98 66 14 20 14 300 350 300 IP54/20 IP54/20 IP54/20 IP65 IP65 (9) plastic plastic plastic plug-in plug-in screw
-10...65 °C 0...85 %RH 'S' 'L' 48x48 72x36 panel panel 45x45 71x29 100 56 10 9 200 150 IP54/20 IP54/20 IP65 plastic plastic screw screw
Not available for case 'L'. Ordered separately (see 'Accessories') Available ONLY for cases 'H', 'V', and 'B'. (9) Ask for availability! (10) Not available for cases 'Q' and 'S'. (8)
RT284U - G0.G1.G4.G5G5.G9'9" - #1.#2
Code Feature or option
Code values
G0
Case (front size)
B - 96x96 mm, H - 96x48 mm, V - 48x96 mm, Q - 72x72 mm, S - 48x48 mm, L - 72x36 mm
G1
Power supply
A - 230 VAC (6), B - 115 VAC (6), C - 90…250 V, E - 9(12) VAC w/ external transformer (7), P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
G4
Adjustment controls
A - keyboard, H - rotary encoder (8)
G5
Relay output
X - none, A - relay NO (3), C - relay NO/NC (3), D - SSR, J - for external SSR, M - isolated MOS gate
G9'
Serial interface
X - none, B - RS485
G9"
Protocol
A - ASCII, C - ASCII for "PolyMonitor"
#1
Increased front protection
X - none, P - IP65 front protection (10)
#2
Customer specified input signal
X - none, Z - custom linear signal (specify!) (1)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
COMECO reserves the right of changing specifications without prior notice!
Input
process controllers Programmable Controller RT384 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
5 DIN cases Universal programmable input Various control algorithms including auto-tuning PID-pulse and PID for motor valves Programmable digital filter Manual mode for bumpless switching Calibration and self-calibration RS485 serial interface available
RT384 is a multifunctional programmable controller with universal input for the most common thermoresistances, thermocouples, and linear signals. The input has a built-in automatic software compensation of line resistance and cold junction temperature as well as automatic software compensation of temperature drift, and can be calibrated manually. RT384 is also equipped with a programmable input filter and a 4-digit display with programmable refresh rate. Available are various options for access restriction. The device can have up to 2 outputs (2 relays or 1 relay and 1 analog output), which can control variety of actuators through different programmable control algorithms. RT384 can work in manual or automatic mode, and an RS485 serial interface enables networking.
Technical specifications (programmable)
Pt100 (w=1.385, 1.391); 3-wire Cu100 (w=1.426, 1.428); 3-wire Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" Thermocouple "C" Thermocouple "L - GOST" Linear voltage 0...50 mV (1) Linear current 0...20 mA Linear current 4...20 mA Input type selection Decimal point selection Digital filter Input calibration
Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Operation modes Control algorithms Auto-tuning Alarms Other control features Analog output (5) Serial interface
-100...600 °C -50...200 °C 0...1000 °C 0...1300 °C 0...1700 °C 0...1700 °C 100...1800 °C 0...2300 °C 0...600 °C -1999...9999, programmable -1999...9999, programmable -1999...9999, programmable (2) programmable programmable programmable programmable (up to 2 outputs) 5A/250V w/ NO/NC or NO (3) contact 1A/250VAC (4) 0.1A/60V, optically isolated 5…24 V, 30 mA manual and automatic ON/OFF, PID-pulse, and PID for motor valves, programmable programmable programmable BUMPLESS and ANTI-WINDUP 4(0)...20 mA or 0...10 V, isolated RS485, isolated
(1)
Other voltage ranges can be obtained by the means of 2 external resistors. Provides loop supply voltage - 24 VDC (only w/ isolated power supply). (3) For case 'Q' and case 'S' w/ serial interface, 1st relay is NO; for cases 'Q' and 'S' w/ SMPS, 2nd relay is NO. (4) 0.2A/250VAC for case 'L' (2)
Ordering code
Accuracy 0.3% (6) from span 0.01% from span for 1 °C automatic software automatic software automatic software
Measurement error Temperature drift Self-calibration Cold junction compensation RTD line compensation
Power supply Mains supply voltage (7) SMPS voltage (7) Isolated low voltage Non-isolated low voltage Consumption
230 VAC or 115 VAC 90…250 V 12…24 V or 24 VAC (7) 12…24 V max. 3 VA
Indication and controls 4 LED indicators 2 LEDs for output state 3 membrane keys
Digital display LEDs Keyboard
Operating conditions Ambient temperature Ambient humidity
Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals)
'B' 'H' / 'V' 'Q' 96x96 96x48 72x72 panel panel panel 90x90 90x42 67x67 98 98 66 20 14 / 10 14 300 350 300 IP54/20 IP54/20 IP54/20 IP65 IP65 (8) plastic plastic plastic plug-in plug-in screw
-10...55 °C 0...85 %RH 'S' 'L' 48x48 72x36 panel panel 45x45 71x29 100 56 10 9 200 150 IP54/20 IP54/20 IP65 plastic plastic screw screw
(5)
Instead of 1st relay! If mounted, it can be programmed as control or retransmission! 0.5% for noble thermocouples (7) Not available for case 'L'. (8) Ask for availability! (9) Not available for cases 'Q' and 'S'. (6)
RT384 - G0.G1.G5G5.G9'9".G11 - #1
Code Feature or option
Code values
G0
Case (front size)
B - 96x96 mm, H - 96x48 mm, V - 48x96 mm, Q - 72x72 mm, S - 48x48 mm, L - 72x36 mm
G1
Power supply
A - 230 VAC (7), B - 115 VAC (7), C - 90…250 V (7), P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC (7)
G5
Relay output
X - none, A - relay NO (3), C - relay NO/NC (3), D - SSR, J - for external SSR, M - isolated MOS gate
G9'
Serial interface
X - none, B - RS485
G9"
Protocol
A - ASCII, C - ASCII for "PolyMonitor"
G11
Analog output (5,8)
X - none, E - 0…20 mA, F - 4…20 mA, K - 0…10 V
#1
Increased front protection
X - none, P - IP65 front protection (9)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
COMECO reserves the right of changing specifications without prior notice!
Input
process controllers Programmable Controller RT484 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
Two 4-digit displays 4 DIN cases Universal programmable input Various control algorithms including auto-tuning PID-pulse and PID for motor valves Programmable digital filter Manual mode for bumpless switching Calibration and self-calibration RS485 serial interface available
RT484 is a multifunctional programmable controller with a universal input for the most common thermoresistances, thermocouples, and linear signals. The input has a built-in automatic software compensation of line resistance and cold junction temperature as well as automatic software compensation of temperature drift, and can be calibrated manually. RT484 is also equipped with a programmable input filter and two 4-digit displays with programmable refresh rate. Available are various options for access restriction. The device can have up to 2 outputs (2 relays or 1 relay and 1 analog output), which can control variety of actuators through different programmable control algorithms. RT484 can work in manual or automatic mode, and an RS485 serial interface enables networking.
Technical specifications (programmable)
Pt100 (w=1.385, 1.391); 3-wire Cu100 (w=1.426, 1.428); 3-wire Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" Thermocouple "C" Thermocouple "L - GOST" Linear voltage 0...50 mV (1) Linear current 0...20 mA Linear current 4...20 mA Input type selection Decimal point selection Digital filter Input calibration
Outputs
-100...600 °C -50...200 °C 0...1000 °C 0...1300 °C 0...1700 °C 0...1700 °C 100...1800 °C 0...2300 °C 0...600 °C -1999...9999, programmable -1999...9999, programmable -1999...9999, programmable (2) programmable programmable programmable programmable (up to 2 outputs)
Relay electromechanical Solid state relay MOS gate Output for external SSR Operation modes Control algorithms Auto-tuning Alarms Other control features Analog output (3) Serial interface
5A/250V w/ NO/NC or NO contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA manual and automatic ON/OFF, PID-pulse, and PID for motor valves, programmable programmable programmable BUMPLESS and ANTI-WINDUP 4(0)...20 mA or 0...10 V, isolated RS485, isolated
Accuracy
Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption
2 x 4 LED indicators 2 LEDs for output state 3 membrane keys
Digital display LEDs Keyboard
Operating conditions Operating temperature Operating humidity
Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] PV display digit height [mm] SV display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals) (4)
(2)
(5)
Ordering code
230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 5 VA
Indication and controls
(1)
Other voltage ranges can be obtained by the means of two external resistors. Provides loop supply voltage - 24 VDC (only w/ isolated power supply) (3) Instead of 1st relay! If mounted, it can be programmed as control or retransmission!
0.3% (3) from span 0.01% from span for 1 °C automatic software automatic software automatic software
Measurement error Temperature drift Self-calibration Cold junction compensation RTD line compensation
(6)
'B' 'H' / 'V' 96x96 96x48 panel panel 90x42 90x90 98 98 20 14 / 10 10 14 300 350 IP54/20 IP54/20 IP65 IP65 (5) plastic plastic plug-in plug-in
-10...55 °C 0...85 %RH 'Q' 'S' 72x72 48x48 panel panel 45x45 67x67 100 66 10 14 10 10 200 300 IP54/20 IP54/20 plastic plastic screw screw
0.5% for noble thermocouples Ask for availability! Not available for cases 'Q' and 'S'
RT484 - G0.G1.G5G5.G9'9".G11 - #1
Code Feature or option
Code values
G0
Case (front size)
B - 96x96 mm, H - 96x48 mm, V - 48x96 mm, Q - 72x72 mm, S - 48x48 mm
G1
Power supply
A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
G5
Relay output
X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate
G9'
Serial interface
X - none, B - RS485
G9"
Protocol
A - ASCII, C - ASCII for "PolyMonitor"
G11
Analog output (3,5)
X - none, E - 0…20 mA, F - 4…20 mA, K - 0…10 V
#1
Increased front protection
X - none, P - IP65 front protection (6)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
COMECO reserves the right of changing specifications without prior notice!
Input
process controllers Universal Programmable Controller RT1800 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
5 DIN sizes Two 4-digit displays plus bargraph Universal programmable input Optional remote set-point input PID-fuzzy auto-tuning with bumpless Auto/Manual Up to 4 relays and analog control output Retransmission analog output available Triple isolation RAMP/SOAK function 2-program-with-up-to-8-point pattern set point available Serial interface available
RT1800 is a microprocessor-based controller with universal input, analog output, and up to 4 relays (control or alarm) that may be controlled through a number of algorithms such as ON/OFF, ON/OFF heating/cooling duplex, motor-valve control, PID, and self-tuning PID. A bumpless auto-manual change-over is built in the PID algorithm. A start-on timer allows one of output relays to be time-controlled. Two displays (for the measured value and for the set point) as well as an output-control bargraph ease operator duties. Carefully protected from electromagnetic disturbances by featuring both input and output optical isolation, RT1800 is well equipped for troublefree operation in harsh industrial conditions.
Technical specifications Pt100 (w=1.385, 1.391); 3-wire Thermocouple "B" Thermocouple "E" Thermocouple "J" Thermocouple "K" Thermocouple "L" Thermocouple "N" Thermocouple "R" Thermocouple "S" Thermocouple "T" Thermocouple "U" Thermocouple "D" Linear voltage -10...50 mV Linear current 0(4)...20 mA Input type/range selection Input isolation Auxiliary input (2) (option) Signal type Function
Control outputs Relay electromechanical (5) Solid state relay MOS gate Output for external SSR Analog output (6) Isolation Control algorithms Auto-tuning Auto/Manual control Pattern set point
Alarm outputs Relay electromechanical Solid state relay (5) MOS gate Output for external SSR
(programmable) (1) -199.9...600.0 °C [6] 0...1820 °C [1] 0...1000 °C [2] 0...400.0(1200) °C [6] 0...400.0(1200) °C [6] 0...800 °C [2] 0...1300 °C [2] 0...1769 °C [2] 0...1769 °C [2] -199.9...400.0 °C [3] -199.9...600.0 °C [3] 0...2320 °C [2] -1999...9999, programmable [4] -1999...9999, programmable [2] programmable optical, 1500 VAC
RS232 or RS485 configuration and networking up to 31 1500 VAC MODEBUS ASCII or RTU
Interface type Function Network devices Isolation Protocol
Accuracy 0.3% from span 0.01% from span for 1 °C 250 ms automatic software automatic software
Measurement error Temperature drift Sample time Cold junction compensation RTD line compensation
Power supply Supply voltage Consumption
85…265 VAC max. 4 VA
Indication and controls 0(4)...20 mA remote set point (3) (up to 2 outputs ) (4) 3A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 24 V, 20 mA 0(4)...20 mA (≤ 600 Ω), 0...10 V (≥ 1 MΩ) optical, 1500 VAC ON/OFF and PID-fuzzy, programmable programmable bumpless, keyboard switched (7) 1(2) programs w/ 16(8) points (up to 2 outputs (3)) (4) 3A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 24 V, 20 mA
Retransmission output (8) (option) Signal type Function Isolation
Serial interface (9)
0(4)...20 mA (≤ 600 Ω), 0...10 V (≥ 1 MΩ) PV or SV transmission optical, 1500 VAC
Digital display (7) Bargraph display LEDs Keyboard
2 x 4 LED indicators st 10-point LED for 1 control output, 0...100% 8 (6 for 'S') control LEDs 5 (4 for 'S') membrane keys
Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity
Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] PV display digit height [mm] SV display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals)
'B' 96x96 panel 91x91 81 14 10 300 IP56/20 IP65 plastic screw
0...50 °C 20...85 %RH -20...65 °C 0...95 %RH, non-condensing 'H' / 'V' 'Q' 'S' 96x48 panel 91x45 81 8 8 225 IP56/20 IP65 plastic screw
72x72 panel 69x69 81 14 10 225 IP56/20 IP65 plastic screw
48x48 panel 45x45 81 8 8 150 IP56/20 plastic screw
(1)
[n] shows the number of sub-ranges that can be selected via the keyboard. nd For cases 'B', 'H', 'V' – instead of interface; for case 'Q' – instead of 2 alarm output; for case 'S' – instead of interface and retransmission analog output For cases 'B', 'H', 'V' – 2 control + 2 alarm or 1 control + 3 alarm; for case 'Q' – 1 control + 2 alarm or 2 control + 1 alarm; for case 'S' – 2 control + 2 alarm (4) For cases 'B', 'H', 'V' 2nd control (3rd alarm) relay is NO; for case 'Q' 2nd control (1st alarm) relay is NO; for case 'S' all relays are NO. (5) Ask for availability! (6) Instead of control relay! (7) Not available for case 'S'! (8) nd st For cases 'H', 'V' – instead of 2 alarm output; for case 'S' – instead of interface or 1 alarm output. (9) st For cases 'B', 'H', 'V' – instead of auxiliary input; for case 'S' – instead of retransmission or 1 alarm output. (2)
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
COMECO reserves the right of changing specifications without prior notice!
Main input
process controllers
Ordering code
RT1800 - G0.G5'G5'.G5"G5"G5".G8.G9'9".G11 - #1.#2.#3
Code Feature or option G0
Case (front size)
G5'
Relay control output
G5"
Relay alarm output
G8
Control algorithm
G9'
Serial interface
G9"
Protocol
G11
Analog control output
#1
Auxiliary input
#2
Analog retransmission output
#3
Increased front protection
Code values B - 96x96 mm, H - 96x48 mm, V - 48x96 mm, Q - 72x72 mm, S - 48x48 mm
(3)
(3)
X - none, C - relay NO/NC
(4)
, D - SSR
(5)
, J - for external SSR, M - isolated MOS gate
X - none, C - relay NO/NC
(4)
, D - SSR
(5)
, J - for external SSR, M - isolated MOS gate
F - PID-fuzzy (ON/OFF), H - PID-fuzzy plus pattern control
(9)
X - none, A - RS232, B - RS485 M - MODEBUS (ASCII), N - MODEBUS (RTU) (6)
X - none, E - 0…20 mA, F - 4…20 mA, K - 0…10 V
(2)
X - none, E - 0…20 mA, F - 4…20 mA X - none, E - 0…20 mA, F - 4…20 mA, K - 0…10 V X - none, P - IP65 front protection
(7)
COMECO reserves the right of changing specifications without prior notice!
(8)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
process controllers Universal Programmable Controller RT1900-R ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
DIN-rail or wall mounting 4-digit display Triple isolation Universal programmable input PID-fuzzy auto-tuning Up to 3 relay and 1 analog outputs RAMP/SOAK pattern control RS485 MODEBUS serial interface USB port for parameter storage
RT1900-R is a DIN-rail mounting microprocessor-based controller with universal input accepting Pt100, 10 thermocouple types and various linear signals. It can have up to 3 relays (control or alarm) and analog output that may be controlled through ON/OFF and self-tuning PID-fuzzy algorithms as well as optional RAMP/SOAK pattern control. A bumpless auto-manual change-over is also built in the PID algorithm. RT1900-R is equipped with 4-digit LED display and 4-button keyboard for programming. A triple input/output/supply isolation protects the controller from electromagnetic disturbances. Communication features include RS485 MODEBUS interface and USB port for program parameter storage. RT1900-R is well equipped for trouble-free operation in harsh industrial conditions.
Technical specifications Pt100 (w=1.385, 1.391); 3-wire Thermocouple "B" Thermocouple "E" Thermocouple "J" Thermocouple "K" Thermocouple "L" Thermocouple "N" Thermocouple "R"("S") Thermocouple "T" Thermocouple "U" Linear DC (mV) Linear DC (V) Linear DC (mA) Linear resistive Linear display Input type/range selection Input isolation
Outputs
(up to 3 outputs) Maximum 2 outputs (2) 5A/250V w/ NO contact 1A/250VAC 0.1A/60V, optically isolated 24 V, 20 mA 0(4)...20 mA (≤ 560 Ω), 0...5(10) V (≤ 20mA) optical, 1500 VAC ON/OFF and PID-fuzzy, programmable programmable 1(2) programs w/ 16(8) points Maximum 3 outputs (2) 5A/250V w/ NO contact
Control outputs - relay electromechanical (3) - solid state relay - MOS gate - output for external SSR (3) - analog output (load) - isolation - control algorithms - auto-tuning - RAMP/SOAK pattern Alarm outputs - relay electromechanical (1) (2)
Communication Serial interface (3) - function - network USB interface - function
isolated RS485, MODEBUS configuration and networking max. 32 devices, max. 1200 m mini-A USB side connector parameter storage
Accuracy Measurement error Temperature drift Sample time Cold junction compensation RTD line compensation
0.3% from span 0.01% from span for 1 °C 250 ms automatic software automatic software
Power supply Supply voltage Consumption
85…265 VAC max. 4 VA
Indication and controls Digital display Status LEDs Keyboard
4 LED indicators, 7 mm 3 LEDs for output and 1 for program 4 tactile keys
Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity
0...50 °C 20...85 %RH -25...65 °C 0...95 %RH, non-condensing
Design and materials Case material DIN-rail mounting Wall mounting Wiring Dimensions Weight Protection level
plastic on 35 mm DIN rail 4 screws screw terminals 40x107x43 mm approx. 115 g IP10
Some linear ranges may require hardware adjustments (contact COMECO) Maximum total outputs: 2 control + 1 alarm, or 1 control + 2 alarm, or 3 alarm
Ordering code
RT1900 - R.G5'G5'.G5"G5"G5".G8.G9.G11
Code Feature or option G5'
Relay control output
G5"
Relay alarm output
G8
Control algorithm
G9
Serial interface (3)
G11 (3)
(programmable) -199.9...600.0 °C, 6 ranges 0...1820 °C, 1 range 0...900 °C, 2 ranges 0...1200 °C, 6 ranges 0...1200 °C, 6 ranges 0...800 °C, 2 ranges 0...1300 °C, 2 ranges 0...1769 °C, 2 ranges -199.9...400.0 °C, 3 ranges -199.9...600.0 °C, 3 ranges min. -10 mV to max. 50 mV, 4 ranges min. -2 V to max.10 V, 9 ranges 0...20 mA, 4...20 mA 0...5 kΩ -1999...9999, programmable DP programmable (1) optical, 1500 VAC
(2)
(2)
Analog control output
Code values X - none, C - relay NO, D - SSR
(3)
, J - for external SSR, M - isolated MOS gate
X - none, C - relay NO F - PID-fuzzy (ON/OFF), H - PID-fuzzy plus pattern control X - none, B - RS485 (MODEBUS) (3)
X - none, E - 0…20 mA, F - 4…20 mA, I - 0…5 V, K - 0…10 V
Ask for availability!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
COMECO reserves the right of changing specifications without prior notice!
Input
process controllers Double Programmable Controller RT218 ♦ ♦ ♦ ♦ ♦
Two RT18 controllers in one housing Self-tuning ON/OFF or PI control algorithm Fixed input Various power supplies Easy programming
RT218 combines two RT18 controllers in one 96x96 mm case. Thanks to its lower cost than the combined cost of 2 separate RT18 controllers, this model is often preferred when 2 technological parameters are controlled in one machine or installation or of separate adjacent processes. Typical applications include control of 2 temperatures, temperature and humidity, pressure and temperature, pH and temperature, and other combinations. Each of the 2 incorporated controllers controls its relay output through an ON/OFF or selftuning PI algorithm, the latter being a convenient solution that saves installation time and costs and provides precise control eliminating temperature cycling and excessive start-up overshoot. The reliable operation even in the presence of electromagnetic disturbances and the attractive price also account for the success of the RT218 controller.
Technical specifications Input
(for each controller) -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(200) °C -9.9(-50)...90.0(200) °C min. -99...max. 500 °C 0...999(600) °C (2) 0...999(850) °C (2) 0...900(600) °C (2) 0...650(550) °C (2) min. -99(0)...max. 900(999) °C (2) -99...900 (0...999) (2,3,4) -99...900 (0...999) (2,3,4) min. -99...max. 999 (2,3,4) min. -99...max. 999 (2,3,4)
Pt50 (w=1.385); 3-wire Pt100 (w=1.385); 3-wire Pt500 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire Cu100; 3-wire Cu50; 3-wire Other RTD (1) Thermocouple "J" Thermocouple "K" Thermocouple "L" Thermocouple "L-GOST" Other thermocouple (1) Linear voltage 0...10 V Linear current 0(4)...20 mA Custom linear voltage; max. 40 V Custom linear current; max. 80 mA
Output
(for each controller)
Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Programmable parameters
5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF, self-tuning PI within input range limits according to control algorithm
Accuracy Measurement error Temperature drift Cold junction compensation RTD line compensation (option)
Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption
Indication and controls Digital display LEDs Keyboard
(for each controller) 0.4% from span 0.005% from span for 1 °C ± 1 °C 0.01% from span for 1 Ω (for each controller) 230 VAC or 115 VAC 90...250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 3 VA (for each controller) 3 LED indicators, 14 mm LED for output state 3 membrane keys
Operating conditions -10...65 °C 0...85 %RH
Operating temperature Operating humidity
Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals Increased front IP (option) (5)
plastic in 90x90 mm panel cut-out plug-in terminals 96x96(front)x107 mm 98 mm max. 600 g IP54 / IP20 IP65
(1)
Custom; specify range within the limits stated. For self-tuning PI algorithm, ONLY the alternative ranges are applicable. Specify lower and upper display limits. (4) Provides loop supply voltage - 24 VDC (only w/ isolated power supply) (5) Ask for availability! (2)
Ordering code
RT218 - G1(G1).G3(G3).G5(G5).G6'6"(G6'6").G8(G8) - #1(#1).#2 (6)
Code Feature or option Power supply
A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
G3
Resolution
B - 1, C - 0.1 (2)
G5
Relay output
X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate
G6'
Input signal
G6"
(6) (7)
Code values
G1
Sensor
B - thermoresistance, C - thermocouple, D - linear, Z - other on request RTD
B - Pt50, D - Pt100, F - Pt500, G - Pt1000, H - Cu50, K - Cu100, Z - other (1)
T/C
J - "J", K - "K", L - "L" , M - "L-GOST", Z - other (1)
linear
B - 0…20 mA (3), C - 4…20 mA (3), K - 0…10 V (3), Z - other (3)
G8
Control algorithm
A - ON/OFF, C - self-tuning PI (7)
#1
Compensation for 3-wire RTD line
X - none, LC - built-in line resistance compensation
#2
Increased front protection
X - none, P - IP65 front protection (5)
Second controller values are in brackets. Specify the direction of control action (heating or cooling relay action).
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
COMECO reserves the right of changing specifications without prior notice!
(3)
process controllers Double Programmable Controller RT228 ♦ ♦ ♦ ♦ ♦
Two RT28 controllers in one housing ON/OFF or PD-for-MV control algorithm Fixed input Various power supplies Easy programming
RT228 combines two RT28 controllers in one 96x96 mm case. Thanks to its lower cost than the combined cost of 2 separate RT28 controllers, this model is often preferred when 2 technological parameters are controlled in one machine or installation or of separate adjacent processes. Typical applications include control of 2 temperatures, temperature and humidity, pressure and temperature, pH and temperature, and other combinations. Each of the 2 incorporated controllers controls its relay outputs through an ON/OFF or PD algorithm, and thanks to these relay duplex outputs (2 relays per controller, 4 relays per whole device), RT228 is best suited for controlling motorized valve actuators or other actuators with 2-way action. The reliable operation even in the presence of electromagnetic disturbances makes the RT228 controller a widely applicable device.
Technical specifications Input
(for each controller) -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(200) °C -9.9(-50)...90.0(200) °C min. -99...max. 500 °C 0...999(600) °C 0...999(850) °C 0...900(600) °C 0...650(550) °C -99(0)...900(999) °C -99...900 (0...999) (2,3) -99...900 (0...999) (2,3) -99...max. 999 (2,3) -99...max. 999 (2,3)
Pt50 (w=1.385); 3-wire Pt100 (w=1.385); 3-wire Pt500 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire Cu100; 3-wire Cu50; 3-wire Other RTD (1) Thermocouple "J" Thermocouple "K" Thermocouple "L" Thermocouple "L-GOST" Other thermocouple (1) Linear voltage 0...10 V Linear current 0(4)...20 mA Custom linear voltage; max. 40 V Custom linear current; max. 80 mA
Outputs
(for each controller, up to 2 relay outputs)
Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Programmable parameters
5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF, PD within input range limits according to control algorithm
Accuracy Measurement error Temperature drift Cold junction compensation RTD line compensation (option)
Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption
Indication and controls Digital display LEDs Keyboard
(for each controller) 0.4% from span 0.005% from span for 1 °C ± 1 °C 0.01% from span for 1 Ω (for each controller) 230 VAC or 115 VAC 90...250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 3 VA (for each controller) 3 LED indicators, 14 mm 2 LEDs for output state 3 membrane keys
Operating conditions -10...65 °C 0...85 %RH
Operating temperature Operating humidity
Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals Increased front IP (option) (4)
plastic in 90x90 mm panel cut-out plug-in terminals 96x96(front)x107 mm 98 mm max. 600 g IP54 / IP20 IP65
(1)
Custom; specify range within the limits stated. Specify lower and upper display limits. Provides loop supply voltage - 24 VDC (only w/ isolated power supply) (4) Ask for availability! (2)
Ordering code
RT228 - G1(G1).G3(G3).G5G5(G5G5).G6'6"(G6'6").G8(G8) - #1(#1).#2 (5)
Code Feature or option Power supply
A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
G3
Resolution
B - 1, C - 0.1
G5
Relay output
X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate
G6'
Input signal
G6"
(5)
Code values
G1
Sensor
B - thermoresistance, C - thermocouple, D - linear, Z - other on request RTD
B - Pt50, D - Pt100, F - Pt500, G - Pt1000, H - Cu50, K - Cu100, Z - other (1)
T/C
J - "J", K - "K", L - "L" , M - "L-GOST", Z - other (1)
linear
B - 0…20 mA (2), C - 4…20 mA (2), K - 0…10 V (2), Z - other (2)
G8
Control algorithm
A - ON/OFF, C - PD
#1
Compensation for 3-wire RTD line
X - none, LC - built-in line resistance compensation
#2
Increased front protection
X - none, P - IP65 front protection (4)
Second controller values are in brackets.
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
COMECO reserves the right of changing specifications without prior notice!
(3)
process controllers Double Programmable Controller RT228U ♦ ♦ ♦
Two RT28U controllers in one case Universal input for 4 RTDs, 6 T/Cs, and 3 linear types RS485 serial interface available
RT228U combines two RT28U controllers in one 96x96 mm case. Thanks to its lower cost than the combined cost of 2 separate RT28U controllers, this model is often preferred when 2 technological parameters are controlled in one machine or installation or of separate adjacent processes. Typical applications are control of 2 temperatures, temperature and humidity, pressure and temperature, pH and temperature, and other combinations. Each of the 2 incorporated controllers is equipped with universal input and controls its relay outputs by an ON/OFF algorithm. Thanks to its programmable inputs and displays as well as relay duplex outputs (2 relays per controller, 4 relays per whole device), RT228U is a widely applicable device.
Technical specifications Input Pt100 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire PTC (1k at 25 °C); 3-wire PTC (2k at 25 °C); 3-wire Thermocouple "T" Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" Linear voltage 0...10 V Linear current 0(4)...20 mA Custom linear (option) (1) Two-wire external transmitter Manual input offset Input type selection Decimal point selection Temperature measurement unit
Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Alarms Serial interface (2) (3)
Measurement error Temperature drift Cold junction compensation RTD line compensation
Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption
Indication and controls Digital display LEDs Keyboard
(for each controller) 0.3% from span 0.02% from span for 1 °C automatic, -10...80 °C automatic, up to 2 х 25 Ω (for each controller) 230 VAC or 115 VAC 90…250 V 12…24 V or 24 VAC 12…24 V max. 1.5 VA (for each controller) 3 LED indicators, 14 mm 2 LEDs for output state 3 membrane keys
Operating conditions -10...65 °C 0...85 %RH
Ambient temperature Ambient humidity
Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals Increased front IP (option) (3)
plastic in 90x90 mm panel cut-out plug-in terminals 96x96(front)x107 mm 98 mm max. 600 g IP54 / IP20 IP65
Instead of linear current Provides loop supply voltage - 24 VDC (only w/ isolated power supply) Ask for availability!
Ordering code
RT228U - G1(G1).G5G5(G5G5).G9'9"(G9'9") - #1.#2(#2) (4)
Code Feature or option
(4)
Accuracy
Code values
G1
Power supply
A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
G5
Relay output
X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate
G9'
Serial interface
X - none, B - RS485
G9"
Protocol
A - ASCII, C - ASCII for "PolyMonitor"
#1
Increased front protection
X - none, P - IP65 front protection (3)
#2
Customer specified input signal
X - none, Z - custom linear signal (specify!) (1)
Second controller values are in brackets.
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(1)
(for each controller, programmable) -100...850 °C -100...600 °C -50...150 °C -50...150 °C -40...400 °C -20...999 °C -20...999 °C 0...999 °C 0...999 °C 100...999 °C -199...999, programmable -199...999, programmable -199...999, programmable 4...20 mA (2) programmable programmable programmable °C or °F, programmable (for each controller, up to 2 relay outputs) 5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF within input range limits programmable RS485, isolated
process controllers 2-channel Programmable Controller RT180 ♦ ♦ ♦ ♦ ♦ ♦
2 independent control channels in one device 2 DIN cases – horizontal and vertical Universal input for 4 RTDs, 4 T/Cs, and 3 linear types ON/OFF- pulse-mode control RH, pH, and ∆t variants available RS485 serial interface available
RT180 offers an exceptionally convenient and inexpensive solution for 2 loopcontrol applications within 1 machine or 2 adjacent ones. The universal programmable inputs make sensor change easy and convenient, and allow on-site configuring of variety of inputs and controlled physical values. The controller may be used for measurement and control of temperature difference (variant 'D'), pH and temperature (variant 'P'), relative humidity through the "wet-and-dry-bulb thermometer" method (variant 'R'), and in other cases in which 1 device measures and controls 2 physical values. All of this make RT180 widely applicable for both industry and laboratory use.
Technical specifications Inputs
(1 per channel, programmable)
Pt100 (w=1.385); 3-wire Pt50 (w=1.385); 3-wire Cu100; 3-wire Cu50; 3-wire Other RTD (1) Thermocouple "J" Thermocouple "K" Thermocouple "L" Thermocouple "L- GOST" Other thermocouple (1) Linear voltage 0...50 mV Linear current 0(4)...20 mA Custom linear 0...50 mV/mA (option) (1) Input type selection (3) pH +2000...-2000 mV Manual input offset
Outputs
-19.9(99)...99.9(500) °C -99...500 °C -9.9(50)...99.9(200) °C -99...200 °C min. -99...max. 500 °C min. 0...max. 900 °C min. 0...max. 999 °C min. 0...max. 600 °C min. 0...max. 600 °C min. 0...max. 999 °C -99...999, programmable (2) (2) -99...999, programmable -99...999, programmable (2) programmable 0...14 pH through keyboard (1 per channel)
Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point
5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF, pulse mode programmable
Serial interface (4) Interface type Protocol
RS485, isolated free ASCII or ASCII for "PolyMonitor"
Accuracy Measurement error Temperature drift Calibration Manual calibration Cold junction compensation RTD line compensation
0.3% from span 0.01% from span for 1 °C automatic software through keyboard automatic software automatic software
Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption
230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 3 VA
Indication and controls Digital display LEDs Keyboard
2 x 3 LED indicators 2 LEDs for output state 4 membrane keys
Operating conditions Operating temperature Operating humidity
Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring
'H' 96x48 panel 90x42 98 9 300 IP54 / IP20 IP65 plastic plug-in terminals
-10...65 °C 0...85 %RH 'V' 48x96 panel 42x90 98 10 300 IP54 / IP20 IP65 plastic plug-in terminals
Instead of a chosen standard input Provides loop supply voltage - 24 VDC (only w/ isolated power supply) pH input is available ONLY for the 1st channel. The 2nd channel must be for temperature correction and/or control (Pt100: -19.9...99.9 °C). (4) Ask for availability! (2) (3)
Ordering code
RT180 - G0.G1.G5G5.G9'9" - #1.#2
Code Feature or option
Code values (5,6)
Variant
N - standard (w/ programmable inputs), D - for temperature difference control , P - for pH control (3,5), R - for relative humidity control (5,6), Z - other on request (4)
G0
Case (front size)
H - 96x48 mm, V - 48x96 mm
G1
Power supply
A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
G5
Relay output
X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate
G9'
Serial interface
X - none, B - RS485 (4)
G9"
Protocol
A - ASCII, C - ASCII for "PolyMonitor"
#1
Increased front protection
X - none, P - IP65 front protection
#2
Customer specified input signal
X - none, Z - custom linear signal (specify!)
(5) (6)
(1)
Variants 'P', 'D', and 'R' have FIXED control algorithm that cannot be altered by the user. The default control algorithm is ON/OFF – the same as in the standard variant. The input types of both channels are fixed to Pt100 with fixed input ranges.
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
COMECO reserves the right of changing specifications without prior notice!
(1)
process controllers Programmable Controller RT390 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
Extremely flexible – unlimited range of applications User-programmable structure by ready-made blocks Powerful self-testing capabilities May be used as pH and RH controller Wide range of control algorithms and alarm types Bumpless Auto/Manual change-over Up to 5 inputs and 5 outputs Digital interface for network operation
RT390 is a compact microprocessor-based controller with user programmable internal structure and very wide range of application. It can be equipped with up to 3 analog and 2 discrete inputs and up to 3 relays and 2 analog outputs and can accept a whole variety of input signals including temperature, relative humidity, flow, pressure, pH, etc. Electromechanical relays, solidstate relays, or current or voltage analog outputs may be installed as control, alarm, or limit comparators. Each relay output may be programmed as time or frequency proportional or as a simple ON/OFF. The 3 analog inputs available allow special applications like positioning control, cascade controllers, pH control (with temperature compensation), etc. The internal structure consists of up to 15 functional blocks. Each functional block may calculate one of the 24 standard functions. Custom defined functions may be added. Bumpless auto/manual changeover is another feature. Network functions and hierarchical control are available with serial interface installed. Keyboard locking is possible by connection of a switch to one of the digital inputs.
Technical specifications Pt100; 3-wire Pt500; 3-wire Pt1000; 3-wire Cu53; 3-wire Cu100; 3-wire Ni100; 3-wire Other RTD Thermocouple "B" Thermocouple "D" Thermocouple "E" Thermocouple "J" Thermocouple "K" Thermocouple "L" Thermocouple "L - GOST " Thermocouple "N" Thermocouple "R" Thermocouple "S" Thermocouple "T" Thermocouple "U" Other thermocouple Linear voltage (Rin ≥ 1 GΩ) (1,2) Custom linear voltage (1,2) Linear current (Rin ≤ 10 Ω) (1,2) Custom linear current (1,2) Linear resistive (1) Linear potentiometer (1) pH input (Rin ≥ 10 TΩ) ORP input (Rin ≥ 10 TΩ) Sub-range selection
Digital inputs Input signal type Limitations Functions
Relay outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Output function Control algorithms and alarm limits Set point (1) (2) (3)
(up to 3 inputs) -200...200 (850) °C -200...200 (850) °C -200...200 (850) °C 0...180 °C -200...200 °C -60...200 °C min. -200...max. 850 °C 200...1820 °C 400...2300 °C -270...1000 °C -210...1200 °C -270...1370 °C -200...900 °C -200...900 °C -270...1300 °C -50...1700 °C -50...1700 °C -270...400 °C -200...600 °C up to 2000 °C 0...2 V, 0...5 V, or 0...10 V 0...max. 10 V 0(4)...20 mA 0...max. 50 mA 0...Rp ≥ 50 Ω 0...Rp ≥ 5 kΩ 0.00...14.00 pH -1000...+1000 mV programmable (up to 2 inputs) contact, TTL, NPN, or PNP Uin. max. ≤ 40 VDC programmable, in combination with certain blocks (up to 3 outputs) 5A/250V w/ NO contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF, time-proportional, or frequency-proportional (3) programmable, according to selected block types within input range limits
Analog outputs
(up to 2 outputs)
Current output Voltage output Other on request Output function Output range
0(4)...20 mA DC (RLOAD ≤ 400 Ω) 0...2/ 5/ 10 VDC (RLOAD ≥ 2/ 5/ 10 kΩ) max. 20 mA or 10 V retransmission / control user-programmable
Digital interface Output type Output function
RS232 or RS485 network, operator station, or hierarchical control
Accuracy Measurement error Temperature drift Calibration Cold junction compensation
0.4% from span 0.005% from span for 1 °C automatic software automatic hardware
Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption
230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 3 VA
Indication and controls Digital display LEDs Keyboard
4 LCD or LED indicators, 13 mm with programmable decimal point 3 LEDs for relay output state, LED for auto/manual mode 4 membrane keys
Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity
-10...65 °C 0...85 %RH -20...65 °C 0...95 %RH, non-condensing
Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals
plastic in 93x45 mm panel cut-out screw terminals 96x48(front)x125 mm 120 mm max. 350 g IP54 / IP20
The correspondence (mapping) of the input signal with displayed value ranges is user programmable. Provides 12...24 VDC / 30 mA supply for external transmitter on one of the linear voltage or current outputs Three types of frequency proportional outputs are available (user programmable). Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
COMECO reserves the right of changing specifications without prior notice!
Analog inputs
process controllers
Programmable structure blocks PID ON/OFF controller ON/OFF duplex controller Positioning control Control error calculation Constant Adder Gain Attenuator Multiplier Divider Linear transformation (mapping) Low pass filter Saturation Dead band "Window" type alarm Inverted "window" type alarm High limit alarm Low limit alarm Timer Generator Time controlled multiplexer Discrete input controlled multiplexer Very long period PWM output Selectable constant (set-point unit) RH measurement by "wet" and "dry" bulb method PID with 2 inputs
Ordering code
industrial PID with anti-windup integration (4 parameters) ON/OFF control (1 parameter) ON/OFF duplex (heating/cooling) control (3 parameters) 2-speed positioning control for motorized valves (4 parameters) compares set point and measured value (1 parameter) constant value (1 parameter) adds 2 signals multiplies input signal by a constant (1 parameter) divides input signal by a constant (1 parameter) multiplies the values of the 2 input signals divides the values of the 2 input signals translates input signal range X1…X2 into output range Y1…Y2 (4 parameters) 3rd order Butterworth low pass filter (no ripple step response) (4 parameters) limits output signal between lower and upper limits (2 parameters) output signal is zero when input is within the dead band (1 parameter) output is active while input is within alarm limits (2 parameters) output is active while input is outside alarm limits (2 parameters) output is active while input above alarm limit (1 parameter) output is active while input below alarm limit (1 parameter) generates a pulse depending on input signal (2 parameters) controlled pulse generator (4 parameters) switches 1 of the 2 input signals to the output at time intervals (2 parameters) switches 1 of the 2 input signals to the output controlled by a discrete input forms PWM signal with time period of up to 9999 s (3 parameters) outputs one of 4 selected constants; controlled by the state of 2 discrete inputs forms signal proportional to RH value from 2 temperature inputs PID module with 2 inputs (input #1 - PV, input #2 - SP)
RT390 - G1.G2.G5G5G5.G6'6"G6'6"G6'6".G7G7.G9'9".G11G11
Code Feature or option
Code values A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
G1
Power supply
G2
Display
A - LCD, C - LED
G5
Relay output
X - none, A - relay NO, J - for external SSR, M - isolated MOS gate
G6'
Input signal
X - none, B - thermoresistance, C - thermocouple, D - linear, Z - other on request
G6"
Sensor
RTD
D - Pt100, F - Pt500, G - Pt1000, H - Cu53, K - Cu100, M - Ni100, Z - other
T/C
B - "B", D - "D", E - "E", J - "J", K - "K", L - "L" , M - "L-GOST", N - "N", R - "R", S - "S", T - "T", U - "U", Z - other
linear
B - 0...20 mA, C - 4...20 mA, H - 0...2 V, I - 0...5 V, K - 0...10 V, L - resistive, 0...Rp, M - potentiometer, 0...Rp, N - pH, O - ORP, Z - other
Discrete input
X - none, A - contact, E - NPN, F - PNP, G - TTL
G9'
Serial interface
X - none, A - RS232, B - RS485
G9"
Protocol
B - RT390, D - RT390 for "PolyMonitor"
G11
Analog output
X - none, E - 0…20 mA, F - 4…20 mA, H - 0…2 V, I - 0...5 V, K - 0...10 V, Z - other on request
COMECO reserves the right of changing specifications without prior notice!
G7
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
level control equipment Level Controller LC05 ♦ ♦ ♦ ♦ ♦ ♦ ♦
Operates with conductive or non-conductive liquids Contact or resistive input Panel mounting Controls level between 2 electrodes with 1 relay output Tank supply or drainage control State indication Low cost
LC05 is a low-cost level controller for supply or drainage level control. Through its relay output, this device directly controls electrical pumps, valves, etc. and may be used either for tank emptying (drainage) or tank filling (supply). Two versions are available employing different methods for level measurement: - LC05 with resistive input., i.e. measuring electrical conductivity of the liquid between electrodes or between electrode and metal tank body, applicable for liquids with relatively high conductivity that are normally used in chemical, paper, food, wine, biotechnological industries, etc; - LC05 with electrical contact input, monitoring float state using magnetic or electromechanical float switches and applicable for various non-conductive liquids or cases of heavy condensation, vaporization, or foaming, such as in heating and water supply installations, etc. LC05 level controller is based on high-tech specialized electronic circuits that guarantee accuracy and stability, prevent electrolytic polarization, and ensure stable operation.
Technical specifications Input
Power supply passive electrical contact ≤ 50 Ω ≥ 500 kΩ conductive electrodes ≤ 50 kΩ ≥ 1…10 MΩ 18 VAC as requested
Contact - ON resistance - OFF resistance Resistive (1) - activation threshold (2) - release threshold (3) - probe voltage Input type
Output Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm
5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF
Indication LED for power ON, LED for output state
LEDs
Mains supply voltage SMPS voltage (4) Isolated low voltage Consumption
230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC (4) or 24 VAC max. 2 VA
Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity
-10...65 °C 0...85 %RH -20...65 °C 0...95 %RH, non-condensing
Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals Increased front IP (option)
plastic in 42x90 mm panel cut-out plug-in terminals 48x96(front)x107 mm 98 mm max. 400 g IP54 / IP20 IP65
(1)
Measures liquid resistance between measuring electrode and reference electrode (tank body) Maximum threshold resistance of activation at reaching (exceeding) the level Minimum threshold resistance of release at falling below the level (4) Ask for availability! (2) (3)
LC05 - G1.G5.G7 - #1
Code Feature or option
Code values
Variant
F - for supply control, E - for drainage control
G1
Power supply
A - 230 VAC, B - 115 VAC, C - 90…250 V (4), Q - 12…24 V, isolated (4), R - 24 VAC
G5
Relay output
C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate
G7
Input
A - contact (float), B - resistive (conductivity cell)
#1
Increased front protection
X - none, P - IP65 front protection
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
level control equipment Programmable Level Controller LC1x ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
With up to 3 relay outputs, for up to 3 levels (independent) May control 2 dependent levels plus alarm Threshold adjustment option Tank supply and drainage control Input from conductivity-cell level electrodes Indication for reached level Panel or DIN-rail mounting Low cost
LC1x is a low-cost electronic level controller available for DIN-rail and panel mounting. It employs measurement of the electrical conductivity of the liquid between electrodes or between electrode and metal vessel case and is applicable for liquids with relatively high conductivity that are normally used in chemical, paper, food, wine, biotechnological industries, etc. The LC10 variant allows monitoring 1 or 2 fixed levels, and LC11 can monitor 1, 2, or 3 fixed levels, and a corresponding relay is activated or deactivated when each level is reached (drainage / supply control). Besides signaling reached level, the output relays may also be used for controlling electrical actuators. The direction of relay action at reached level as well as the connection (dependence) between levels is user-selectable. The device can also be configured as a drainage or supply level controller with alarm relay. A high-tech microprocessor circuit guarantees accuracy and stability, prevents electrolytic polarization, and ensures stable operation. A possibility to adjust output activation threshold as well as an LED indication makes the LC1x level controller a solution for a wide range of level related problems.
Technical specifications Input
Power supply
Input type (1)
resistive, from conductivity cell electrodes 10…1000 kΩ 10…2000 kΩ max. 5000 pF by trimmers on front panel jumper selectable (3) each level controls a relay 1 relay, controlled by 2 levels (up to 3 relay outputs) 5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF jumper selectable (3)
- activation threshold - release threshold Input wiring capacitance Threshold adjustment Operation modes: - independent levels - dependent levels
Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Drainage/supply control
Indication LED for power ON (2), 3 LEDs for output state (4), 3 LEDs for reached levels
LEDs
Mains supply voltage SMPS voltage (5) Isolated low voltage Consumption
230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC (5) or 24 VAC max. 2 VA
Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity
Design and materials Dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) (6) Case material Wiring
-10...65 °C 0...85 %RH -20...65 °C 0...95 %RH, non-condensing 'V' 48x96(front)x107 panel 42x90 98 500 IP44 / IP20 IP65 plastic plug-in terminals
'R' 70x110x58 DIN-rail 53 500 IP20 plastic plug-in terminals
(1)
Measures liquid resistance between measuring electrode and reference electrode (tank body) Available ONLY for case 'V' Factory settings: 3 independent levels with drainage action; different factory settings are available on request. (4) Available ONLY for case 'R' (5) Ask for availability! (6) Not available when threshold-adjustment trimmers are mounted! (2)
Ordering code
LC1 - G0.G1.G5G5G5.G7G7G7 - #1.#2 (7)
Code Feature or option
0 - for up to 2 levels, with 2 relay outputs, 1 - for up to 3 levels, with 3 relay outputs
G0
Case
V - for panel mounting, R - for DIN-rail mounting
G1
Power supply
A - 230 VAC, B - 115 VAC, C - 90…250 V (5), Q - 12…24 V, isolated (5), R - 24 VAC
G5
Relay output
X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate
G7
Input
X - none, B - resistive (conductivity cell)
#1
Threshold adjustment
#2 (7)
Code values
Variant
Increased front protection
X - none, A - threshold-adjustment trimmers mounted (6)
X - none, P - IP65 front protection
G5G5.G7G7 for variant '0'
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(3)
level control equipment Programmable Level Controller LC1x ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
With up to 3 relay outputs, for up to 3 levels (independent) May control 2 dependent levels plus alarm Threshold adjustment option Tank supply and drainage control Input from conductivity-cell level electrodes Indication for reached level Panel or DIN-rail mounting Low cost
LC1x is a low-cost electronic level controller available for DIN-rail and panel mounting. It employs measurement of the electrical conductivity of the liquid between electrodes or between electrode and metal vessel case and is applicable for liquids with relatively high conductivity that are normally used in chemical, paper, food, wine, biotechnological industries, etc. The LC10 variant allows monitoring 1 or 2 fixed levels, and LC11 can monitor 1, 2, or 3 fixed levels, and a corresponding relay is activated or deactivated when each level is reached (drainage / supply control). Besides signaling reached level, the output relays may also be used for controlling electrical actuators. The direction of relay action at reached level as well as the connection (dependence) between levels is user-selectable. The device can also be configured as a drainage or supply level controller with alarm relay. A high-tech microprocessor circuit guarantees accuracy and stability, prevents electrolytic polarization, and ensures stable operation. A possibility to adjust output activation threshold as well as an LED indication makes the LC1x level controller a solution for a wide range of level related problems.
Technical specifications Input
Power supply
Input type (1)
resistive, from conductivity cell electrodes 10…1000 kΩ 10…2000 kΩ max. 5000 pF by trimmers on front panel jumper selectable (3) each level controls a relay 1 relay, controlled by 2 levels (up to 3 relay outputs) 5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF jumper selectable (3)
- activation threshold - release threshold Input wiring capacitance Threshold adjustment Operation modes: - independent levels - dependent levels
Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Drainage/supply control
Indication LED for power ON (2), 3 LEDs for output state (4), 3 LEDs for reached levels
LEDs
Mains supply voltage SMPS voltage (5) Isolated low voltage Consumption
230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC (5) or 24 VAC max. 2 VA
Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity
Design and materials Dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) (6) Case material Wiring
-10...65 °C 0...85 %RH -20...65 °C 0...95 %RH, non-condensing 'V' 48x96(front)x107 panel 42x90 98 500 IP44 / IP20 IP65 plastic plug-in terminals
'R' 70x110x58 DIN-rail 53 500 IP20 plastic plug-in terminals
(1)
Measures liquid resistance between measuring electrode and reference electrode (tank body) Available ONLY for case 'V' Factory settings: 3 independent levels with drainage action; different factory settings are available on request. (4) Available ONLY for case 'R' (5) Ask for availability! (6) Not available when threshold-adjustment trimmers are mounted! (2)
Ordering code
LC1 - G0.G1.G5G5G5.G7G7G7 - #1.#2 (7)
Code Feature or option
0 - for up to 2 levels, with 2 relay outputs, 1 - for up to 3 levels, with 3 relay outputs
G0
Case
V - for panel mounting, R - for DIN-rail mounting
G1
Power supply
A - 230 VAC, B - 115 VAC, C - 90…250 V (5), Q - 12…24 V, isolated (5), R - 24 VAC
G5
Relay output
X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate
G7
Input
X - none, B - resistive (conductivity cell)
#1
Threshold adjustment
#2 (7)
Code values
Variant
Increased front protection
X - none, A - threshold-adjustment trimmers mounted (6)
X - none, P - IP65 front protection
G5G5.G7G7 for variant '0'
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(3)
level control equipment Level Controller LC20 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
Operates with conductive or non-conductive liquids Contact or resistive input Rail mounting Optional threshold adjustment Controls level between 2 electrodes with 1 relay output Tank supply or drainage control State indication Low cost
LC20 is a low-cost electronic level controller/indicator for rail mounting. Through its relay output, this device directly controls electrical pumps, valves, etc. and may be used either for tank emptying (drainage) or tank filling (supply). Two versions are available employing different methods for level measurement: - LC20 with resistive input., i.e. measuring electrical conductivity of the liquid between electrodes or between electrode and metal tank body, applicable for liquids with relatively high conductivity that are normally used in chemical, paper, food, wine, biotechnological industries, etc; - LC20 with contact input, accepting signals from contact level switches (float, optical, etc.), applicable for various non-conductive liquids or cases of heavy condensation, vaporization, or foaming, such as in heating and water supply installations, etc. An optional output activation threshold adjustment via potentiometer on the front panel provides better adaptation to liquids with different conductivity for both versions.
Technical specifications Input
Power supply
Contact (1) - ON resistance - OFF resistance Resistive (2) - activation threshold (3) - release threshold (4) - probe voltage Input type Threshold adjustment (option)
passive electrical contact ≤ 50 Ω ≥ 500 kΩ conductivite electrodes ≤ 50 kΩ ≥ 1…10 MΩ 18 VAC as requested via front-panel potentiometer, 10...50 kΩ
Output Relay electromechanical Solid state relay (1) MOS gate (1) Output for external SSR Control algorithm
5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF
Indication LED
LED for output state
Mains supply voltage SMPS voltage (1) Isolated low voltage Consumption
230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC (1) or 24 VAC max. 2 VA
Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity
-10...65 °C 0...85 %RH -20...65 °C non-condensing, 0...95 %RH
Design and materials Case material Mounting Wiring Dimensions Weight Protection, front/terminals
plastic on 35 mm DIN rail screw terminals 45x78x124 mm max. 400 g IP40 / IP20
(1)
Ask for availability! (2) Measures liquid resistance between measuring electrode and reference electrode (tank body) (3) Maximum threshold resistance of activation at reaching (exceeding) the level (4) Minimum threshold resistance of release at falling below the level
LC20 - G1.G5.G7 - #1
Code Feature or option
Code values
Variant
F - for supply control, E - for drainage control
G1
Power supply
A - 230 VAC, B - 115 VAC, C - 90…250 V (1), Q - 12…24 V, isolated (1), R - 24 VAC
G5
Relay output
C - relay NO/NC, D - SSR (1), J - for external SSR, M - isolated MOS gate (1)
G7
Input
A - contact (float) (1), B - resistive (conductivity cell)
#1
Threshold adjustment
X - none, A - potentiometer for threshold adjustment
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
level control equipment Level-Switch Isolating Unit LCI2x ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
Isolating amplifier with up to 2 channels Operates with ATEX level switches series LCSFT Provides 2.5 V sensor voltage Isolated AC/DC power supply Output and power state indication 750 V isolation Rail mounting Low cost
The LCI2x isolating amplifier is a low-cost isolating unit with robust plastic case for rail mounting, especially designed to be used with COMECO’s ATEX-approved float level switches series LCSFT. The isolator operates with a wide range of power supply voltages and provides an isolated sensor voltage of only 2.5 V. The internal optical isolator and pulse transformer ensure an isolation level of 750 V. LCI2x can be ordered either with 1 input and 1 relay output, or, when the application requires controlling high and low level points, with 2 inputs and 2 corresponding output relays. Up to 3 LEDs provide convenient indication of the output and power state. The excellent price-toperformance ratio makes the remote isolating unit LCI2x a very useful device for low-cost Ex applications in liquid level control.
Technical specifications Inputs
(1 per channel) OFF/ON, resistive: 20/10 kΩ ± 10% 2.5 VDC ≤ 63 µA 750 VAC for 1 min
Input signal Input (sensor) voltage Input (sensor) current Isolation from output
Outputs
(1 per channel)
Relay electromechanical Solid state relay (1) MOS gate (1) Output for external SSR Switching hysteresis
5A/250V w/ NO contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ≤ 0.01% of span
Indication up to 2 red LEDs for output state, green LED for power ON
LEDs (1)
Isolated low voltage SMPS voltage (1) Isolation from input Consumption
8...28 VAC/DC 90…250 VAC/DC 750 VAC for 1 min max. 2 VA
Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity
-10...65 °C 0...85 %RH -20...65 °C non-condensing, 0...95 %RH
Design and materials Case material Mounting Wiring Dimensions Weight Protection, front/terminals
plastic on 35 mm DIN rail plug-in terminals 35x110x58 mm max. 250 g IP54 / IP20
Ask for availability!
Ordering code
LCI2 - G1.G5 (2)
Code Feature or option
Code values
Variant
0 - single-channel, 2 - double-channel
G1
Power supply
C - 90…250 V (1), Q - 8…28 V, isolated
G5
Relay output
A - relay NO, D - SSR (1), J - for external SSR, M - isolated MOS gate (1)
G5G5 for variant '2'
COMECO reserves the right of changing specifications without prior notice!
(2)
Power supply
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
process controllers Field Mounting ON/OFF Controller RT38-Y ♦ ♦ ♦ ♦ ♦ ♦ ♦
Ready to incorporate temperature or other sensor Direct in-process mounting Relay control output switching power supply Semi-universal input Mains or low-voltage power supply Fully programmable parameters IP66 protection class
RT38-Y is a programmable ON/OFF controller, designed for direct control over temperature or other processes when coupled with a TSEC temperature probe or other sensor. The device is equipped with a 3-digit LED display and a control relay. Available are 2 universal-input versions – RTD (for 7 selectable Ptx and 4 Cux sensor types) and T/C (for 3 selectable thermocouples) – as well as versions for linear current and voltage signals. The controller can be ordered either for mains or for low-voltage power supply and allows an automatic software compensation of line resistance and cold junction temperature. The display-to-input correspondence (in case of linear input), decimal point position, temperature measurement unit, and offset value are also programmable. RT38-Y is enclosed in a robust plastic box with IP66 connector and enables easy and firm sensor assembly. Thanks to its design, RT38-Y is widely applicable in cases, in which direct control of electrical actuators is required.
Technical specifications Input
Power supply
RTD, DIN (w=1.385); 3-wire RTD, GOST (w=1.391); 3-wire RTD measurement range Thermocouple "T" Thermocouple "J" Thermocouple "K" Linear voltage 0...10 V Linear current 0(4)...20 mA Two-wire external transmitter RTD or T/C type selection Decimal point selection Temperature measurement unit
Pt50, Pt100, Pt500, Pt1000 Pt46, Pt50, Pt100, Cu50, Cu100 -100...600 °C -40...400 °C -20...999 °C -20...999 °C -199...999, programmable -199...999, programmable 4...20 mA (1) programmable programmable °C or °F, programmable
Output
Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage External mains transformer (2) Consumption
230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC 9(12) VAC max. 1.5 VA
Indication and controls 3 LED indicators, 14 mm LED for output state 3 membrane keys
Digital display LEDs Keyboard
Operating conditions
Relay electromechanical Solid state relay MOS gate Output for external SSR Direct power supply switching Control algorithm Set point Alarms
5A/250V w/ NO contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA OFF - open circuit; ON - supply voltage ON/OFF within input range limits programmable
Accuracy Measurement error Temperature drift Cold junction compensation
0.3% from span 0.02% from span for 1 °C automatic, -10...80 °C
Ambient temperature Ambient humidity
-10...65 °C 0...85 %RH
Design and materials Case material Controller mounting Probe mounting Power wiring Probe wiring Dimensions Protection, enclosure/terminals
ABS plastic on probe top or free (3) axial (box bottom) or radial (connector opposite) 4-pin М12 connector, always on top 4-pin М12 connector or direct (4) 92x92x60 mm IP66 / IP65
Provides loop supply voltage - 24 VDC (only w/ isolated power supply). Ordered separately (see 'Accessories'). (3) May be mounted on plate or rail by special accessories, which are ordered separately (see 'Accessories'). (4) Order separately! Suitable for assembly are temperature probes type TSEC w/ head connection M12x1.5 (see 'Temperature Probes'). (2)
Ordering code
RT38 - Y.G1.G5.G6.G12'12"
Code Feature or option
Code values
G1
Power supply
A - 230 VAC, B - 115 VAC, C - 90…250 V, E - 9(12) VAC w/ external transformer (2), P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
G5
Output
X - none, A - relay NO, D - SSR, J - for external SSR, M - isolated MOS gate, Y - power supply
G6
Input
B - RTD (programmable), C - thermocouple (programmable), D - 0(4)…20 mA, DK - 0…10 V
G12'
Probe connection
I - direct (4), E - via connector
G12"
Probe position
A - axial, R - radial
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(1)
level control equipment Float Level Probe with Controller LCF ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
2-level control with 1 relay output User-selectable filling or drainage control Various float types 135 °C maximum liquid temperature Mains or low-voltage power supply Vertical adjustment option ATEX certified Ex version available Cost saving solutions
COMECO's level controller LCF combines a 2-point float-type level probe LCSFC and a standard LC05 controller installed inside an ABS protective enclosure with IP66. Large variety of versions based on different plastic and stainless steel floats is available. Floats with different dimensions and specific gravity are available for liquid density down to 0.5 g/cm3, temperature up to 135 °C, and pressure up to 50 bar. Various process connections as well as an option for vertical adjustment are available. LCF can be used for liquid filling or emptying control by switching on and off vessel supply or drainage devices such as pumps and magnet valves. The controller allows the operator to select relevant output relay action for either supply or drainage control. Thanks to the compact combination of probe and in-head controller, LCF can be very useful for building cost-saving level control applications.
Probe specifications LCF
Model B
A
L2
L0
L1
LX
Vertical Adjustment 10% of L0
Specifications Float type
N1
P1
P10
P2
P3
P4
S0/S1/S7/S10
S2
S3
S4
S5
S6
Float material Liquid density [g/cm3]
NBR > 0.80
PP > 0.60
PP > 0.72
PP > 0.60
PP > 0.50
PVDF > 0.70
SS > 0.80
SS > 0.70
SS > 0.65
SS > 0.55
SS > 0.55
SS > 0.50
Ext. tube diameter ('d')
8 mm
8 mm
10 mm
12 mm
16 mm
16 mm
10 mm
14 mm
14 mm
100...1500 100...2500
Min. end-to-float distance ('A') [mm]
23
21
15
37
47
47
22/25/25/29
34
40
39
50
70
Min. float running distance ('B') [mm]
27
24
17
52
62
62
25/30/30/34
40
57
54
75
110
12 bar
30 bar
30 bar
10 bar
min. 2"
min. 2"
-20…100 °C
Max. process pressure Wetted parts
0 bar
5 bar
5 bar
3 bar
min. ½" (M20)
min. 1" (M33)
min. 1" (M33)
min. 1" (M33)
Process connection
-20…80 °C
100...1000
16/18 mm 16/18 mm
100...1000
Process temperature
200...4000
8 mm
Probe length ('L0') [mm]
100...2000 200...3000 200...3000 300...4000 300...5000
-30…125 °C 3 bar
-20…135 °C
2 bar 8/10/30/50 bar 30 bar stainless steel or plastic
min. 1 ¼"
min. 1" (M33)
min. 1½"
min. 3" or flange
Controller specifications Input Input type
Power supply float position – low or high
Output Relay electromechanical Solid state relay (1) MOS gate (1) Output for external SSR Control algorithm Operation mode
8A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF, filling or emptying, user-selectable
Indication LEDs (1)
red LED for output state
Ask for availability!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
Mains supply voltage SMPS voltage (1) Isolated low voltage Non-isolated low voltage Consumption
230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC (1) or 24 VAC 24 VDC max. 2 VA
Operating conditions Ambient temperature Ambient humidity
-10...65 °C 0...85 %RH
Design and materials Case material Wiring Dimensions Protection class
ABS plastic screw terminals via PG9 cable glands 80x80x60 mm (w/o glands) IP66
COMECO reserves the right of changing specifications without prior notice!
A
level control equipment
Ordering code
LCF - G0.G1.G5.G6.G9.G10 - #1
Code Feature or option Power supply
A - 230 VAC, B - 115 VAC, C - 90…250 V (1), D - 24 VDC, non-isolated, Q - 12…24 V, isolated (1), R - 24 VAC
G1
Float
N1 - NBR, ø15x25, P1 - PP, ø24x22, P2 - PP, ø29x50, P3 - PP, ø38x60, P4 - PVDF, ø38x60, P10 - PP, ø29x11, S0 - stainless steel, ø25x25, S1 - stainless steel, ø28x28, S2 - stainless steel, ø41x38, S3 - stainless steel, ø45x55, S4 - stainless steel, ø52x52, S5 - stainless steel, ø73x73, S6 - stainless steel, ø75x108, S7 - stainless steel, ø30x28, S10 - stainless steel, ø30x32, S20 - stainless steel, ø22x40
G5
Relay output
G0
C - relay NO/NC, D - SSR (1), J - for external SSR, M - isolated MOS gate (1) (2)
G6
Operating lengths [mm]
L0/L1/L2
G9
Process connection
X - none, Q2 - M20x1.5, Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q13 - G1½", Q14 - G2", Q15 - 1" NPT, Q16 - 1½" NPT, Q17 - 2" NPT, Q21 - G3", Q22 - 3" NPT, Q25 - M33x2, Q27 - G1¼", Q28 - 1¼" NPT, F - flange (specify!), Z - other (specify!)
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404, M15 - 1.4362
#1
Vertical adjustment
X - none, A - vertical adjustment via stainless steel ferrule installed
Specify the exact length (step 50 mm) from the thread, flange, or box bottom to the respective contact according to the limits given in the specification table, strictly observing 'A' and 'B' minimum distances! 1st contact → 'L1'; e.g.: LCF - A.S1.C.500/50/200.Q12.M1
COMECO reserves the right of changing specifications without prior notice!
(2)
Code values
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
pressure and flow control equipment Flow Controller PSF21x ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
Excellent price-to-performance ratio Unique ultra-light-rotor technology Exceptional accuracy and reliability Operates with liquids with viscosity from 1 to 1000 CST Pulse output with 6000 pulses per liter of water Alarm/Control output with 2 programmable limits Local programmable LED display Chemically resistant variant available
PSF21x is a programmable flow controller designed for use with low-viscose clear or translucent liquids, transmitting IR light. The operating principle is based on the liquid volume measurement through light-weight rotor, IR sensor, and sophisticated electronics for measurement and control. The material types used (PVDF, Vectra®, Viton®, EPDM, etc.) have a good thermal (up to 90 °C) resistance. A special variant with increased chemical resistance also extends the controller application. Other ranges except the standard 0.5…20 l/min are available on request. PSF21x is equipped with a local 3-digit LED display and a hidden key for easy programming and flow monitoring. Output capabilities include TTL pulse output as well as PNP or NPN alarm output that activates when either of the programmable alarm limits is reached. PSF21x can be used as a flow meter, flow transmitter with pulse output, ON/OFF flow controller, or alarm unit suitable for water treatment and other applications.
Technical specifications Input
Local indicator
Liquid type
clear or translucent liquid transmitting IR light (1) 1...1000 CST 0.5...20 l/min (2)
Liquid viscosity Flow range
Measurement accuracy ± 1.00% 1.00% max. ± 0.30%
Accuracy Interchangeability Reproducibility
Outputs Pulse output Sensitivity Alarm output Alarm type Alarm function
TTL, 100...2000 Hz, max. 0.5 mA 6000 pulses per liter of water PNP/NPN, max. 100mA/40V, NO 'window' ON/OFF
Power supply 18...30 VDC 2 Vp-p at 50 Hz max. 200 mA
Supply voltage Admissible variations Consumption (2)
Operating conditions Process temperature Ambient temperature Process pressure
Design and materials Wetted parts Seals Case material Mounting Process connection Wiring Dimensions Weight Protection class (housing)
PSF210 POM, PVDF, Viton®, Vectra®, EPDM NBR POM free 2 x G1/2”, male 3(4)-wire PVC cable 105x60x45 mm max. 200 g IP67
-20...90 °C -10...65 °C max. 12 bar PSF211 SS, PVDF, Viton®, Vectra®, EPDM PTFE POM free 2 x G1/2”, male 3(4)-wire PVC cable 105x60x45 mm max. 250 g IP67
Liquid medium must be compatible with wetted part and seal materials! Other ranges are available on request.
Ordering code
PSF21 - G5.G9.G12
Code Feature or option
Code values
Variant
0 - standard, 1 - chemically resistant (3)
G5
Relay output
E - NPN, F - PNP
G9
Pulse output
X - none, P - 6000 TTL pulses/l
G12
Cable length [m] and type
1PV…10PV - PVC
(3)
3 LED indicators, 10 mm 0.1 l/min 1s 0.01% from span for 1 °C for alarm event 1 hidden key
Limited with wetted part and seal material resistance!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(1)
Digital display Display resolution Display refresh Temperature drift LED indicator Keyboard
timers and counters Dial-type Analog Timer CT02 ♦ ♦ ♦ ♦ ♦ ♦
Very low cost Wide time range 48x48 mm or 96x48 mm DIN-sized front panel 8 operating modes Main and auxiliary relays Panel or rail mounting
The CT02 timer is designed for time sequence control of electrical actuators. The time setting adjustment is done by rotating a dial on the front panel and the timing is started at power-on or by external 'start/stop' contact. Various modes of operation – on-delay, off-delay, pulse output, and cyclical output – are available. The operating modes as well as the time range (for variant 'S') can be selected via micro switches. The timer may be equipped with up to 2 relays – main timing relay and auxiliary relay, which is activated at power-on or simultaneously with the main relay. CT02 has no indication, is very easy to set and operate, and yet has all the main functions of a modern electronic timer.
Technical specifications Input
(1)
Indication and controls
Input type Input function
Times and modes Ranges (3) Dial multiplication coefficient Delay Output pulse Cyclic mode
Outputs Relay electromechanical Solid state relay (4) MOS gate Transistor gate (5) Output for external SSR Main (timer) relay Auxiliary relay
passive contact (NO) external 'Start/Stop' or front-panel 'Start/Stop' button (2) 'N' 'S' 1...10 s, 10...100 s, 0...1, 0...3, 0...6 1...10 min, 10...100 min - x1 s, x10 s, x1 min ON or OFF ON or OFF no yes no yes (up to 2 - main and auxiliary) 5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated open collector, 40mA/40V 12/24 V, 30 mA time operated activates at power-on (6)
Accuracy 1% (2% for 'N') from span 0.007% from span for 1 °C
Measurement error Temperature drift
LEDs Rotating dial Micro switches
LED for the time operated relay for time adjustment for mode selection and multiplication coefficient setting (7)
Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity
Design and materials Case material Mounting
230 VAC or 115 VAC 24…230 VAC/DC 24 VDC 24 VDC max. 2 VA
plastic 'H': in 93x45 mm panel cut-out; 'S': in 45x45 mm panel cut-out or on 35 mm DIN rail
Wiring: - for variant 'N' - for variant 'S' Dimensions: - for variant 'N'
Power supply Mains supply voltage (1) SMPS voltage (7) Isolated low voltage (1) Non-isolated low voltage Consumption
-10...65 °C 0...85 %RH -20...65 °C 0...95 %RH, non-condensing
- for variant 'S' Mounting depth Weight Protection, front/terminals
'H': screw terminals; 'S': socket UNDECAL (8) socket OCTAL (8) 'H': 96x48(front)x136 mm; 'S': 48x48(front)x102 mm 48x48(front)x95 mm 'H': 120 mm; 'S': max. 105 mm (w/ socket) max. 250 g IP40 / IP20
(1)
Only for variant 'N' Only for case 'H' For variant 'S', ranges are user selectable; for variant 'N', they are fixed and should be specified in customer order. (4) Ask for availability! (5) ONLY with isolated power supply! (6) For variant 'S', a mode may be selected when auxiliary relay operates TOGETHER WITH the main time operated relay. (7) Only for variant 'S' (8) Ordered separately (see 'Accessories') (2)
Ordering code
CT02 - G0.G1.G4.G5G5.G8
Code Feature or option
(9)
Code values
Variant
N - normal, S - simplified
G0
Case (front panel) (1)
S - 48x48 mm, H - 96x48 mm
G1
Power supply
A - 230 VAC (1), B - 115 VAC (1), D - 24 VDC, non-isolated, K - 24…230 V (7), Q - 24 VDC, isolated (1)
G4
Start/Stop
A - at power-on, C - from front-panel button (2), D - from input (1)
G5
Relay output
X - none (9), C - relay NO/NC, D - SSR (4), E - open collector NPN (5), J - for external SSR, M - isolated MOS gate
G8
Operating mode (1)
B - selectable, D - delay ON, E - delay OFF, F - output pulse, G - cyclic
A main relay MUST be installed!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(3)
timers and counters Dial-type Analog Timer CT02 ♦ ♦ ♦ ♦ ♦ ♦
Very low cost Wide time range 48x48 mm or 96x48 mm DIN-sized front panel 8 operating modes Main and auxiliary relays Panel or rail mounting
The CT02 timer is designed for time sequence control of electrical actuators. The time setting adjustment is done by rotating a dial on the front panel and the timing is started at power-on or by external 'start/stop' contact. Various modes of operation – on-delay, off-delay, pulse output, and cyclical output – are available. The operating modes as well as the time range (for variant 'S') can be selected via micro switches. The timer may be equipped with up to 2 relays – main timing relay and auxiliary relay, which is activated at power-on or simultaneously with the main relay. CT02 has no indication, is very easy to set and operate, and yet has all the main functions of a modern electronic timer.
Technical specifications Input
(1)
Indication and controls
Input type Input function
Times and modes Ranges (3) Dial multiplication coefficient Delay Output pulse Cyclic mode
Outputs Relay electromechanical Solid state relay (4) MOS gate Transistor gate (5) Output for external SSR Main (timer) relay Auxiliary relay
passive contact (NO) external 'Start/Stop' or front-panel 'Start/Stop' button (2) 'N' 'S' 1...10 s, 10...100 s, 0...1, 0...3, 0...6 1...10 min, 10...100 min - x1 s, x10 s, x1 min ON or OFF ON or OFF no yes no yes (up to 2 - main and auxiliary) 5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated open collector, 40mA/40V 12/24 V, 30 mA time operated activates at power-on (6)
Accuracy 1% (2% for 'N') from span 0.007% from span for 1 °C
Measurement error Temperature drift
LEDs Rotating dial Micro switches
LED for the time operated relay for time adjustment for mode selection and multiplication coefficient setting (7)
Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity
Design and materials Case material Mounting
230 VAC or 115 VAC 24…230 VAC/DC 24 VDC 24 VDC max. 2 VA
plastic 'H': in 93x45 mm panel cut-out; 'S': in 45x45 mm panel cut-out or on 35 mm DIN rail
Wiring: - for variant 'N' - for variant 'S' Dimensions: - for variant 'N'
Power supply Mains supply voltage (1) SMPS voltage (7) Isolated low voltage (1) Non-isolated low voltage Consumption
-10...65 °C 0...85 %RH -20...65 °C 0...95 %RH, non-condensing
- for variant 'S' Mounting depth Weight Protection, front/terminals
'H': screw terminals; 'S': socket UNDECAL (8) socket OCTAL (8) 'H': 96x48(front)x136 mm; 'S': 48x48(front)x102 mm 48x48(front)x95 mm 'H': 120 mm; 'S': max. 105 mm (w/ socket) max. 250 g IP40 / IP20
(1)
Only for variant 'N' Only for case 'H' For variant 'S', ranges are user selectable; for variant 'N', they are fixed and should be specified in customer order. (4) Ask for availability! (5) ONLY with isolated power supply! (6) For variant 'S', a mode may be selected when auxiliary relay operates TOGETHER WITH the main time operated relay. (7) Only for variant 'S' (8) Ordered separately (see 'Accessories') (2)
Ordering code
CT02 - G0.G1.G4.G5G5.G8
Code Feature or option
(9)
Code values
Variant
N - normal, S - simplified
G0
Case (front panel) (1)
S - 48x48 mm, H - 96x48 mm
G1
Power supply
A - 230 VAC (1), B - 115 VAC (1), D - 24 VDC, non-isolated, K - 24…230 V (7), Q - 24 VDC, isolated (1)
G4
Start/Stop
A - at power-on, C - from front-panel button (2), D - from input (1)
G5
Relay output
X - none (9), C - relay NO/NC, D - SSR (4), E - open collector NPN (5), J - for external SSR, M - isolated MOS gate
G8
Operating mode (1)
B - selectable, D - delay ON, E - delay OFF, F - output pulse, G - cyclic
A main relay MUST be installed!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(3)
timers and counters 2-period Multifunctional Timer CT03 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
Fully programmable 2 time periods with 2 relay outputs Easy-to-set push-wheel switch External or power-on starting modes HOLD input Maximum time delay up to 999 min 4 operating modes 48x48 mm DIN-sized front panel
The CT03 timer is a low-cost microprocessor-based device for time sequence control with 2 adjustable time periods forming a time cycle, 3 sub-ranges, and 4 different timing modes. The push-wheel switch (BCD) on the front panel enables easy setting of the period duration and the 3-digit display indicates the current time, the parameters, or the operating mode. All modes of operation and parameters are user-programmable via front-panel keyboard. CT03 is also equipped with 2 contact inputs for external start and hold and 2 output relays with programmable action for timing control of processes through switching electrical actuators on and off. The extended features of CT03 simplify programming and process monitoring and make the timer a convenient solution to a wide range of timing related problems.
Technical specifications Inputs
Indication and controls
Input type Input START Input HOLD Input programming
NO contacts external closing contacts external closing contacts through keyboard
Times and modes
Digital display LEDs Keyboard Push-wheel switch
3 LED indicators, 10 mm 2 LEDs for relay state 2 membrane keys for easy value programming
Power supply
Ranges First period (t1) Second period (t2) Modes of operation Range selection Time selection Parameter programming Value adjustment
Outputs Relay electromechanical Solid state relay (3) MOS gate Transistor gate (4) Output for ext. SSR Relay K1 action Relay K2 action
0...99.9 s, 999 s, or 999 min after start depends on the operation mode up to 4 modes (1) programmable programmable through keyboard (2) by push-wheel switch (up to 2 relay outputs) 5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated open collector, 40mA/40V 5...24 V, 30 mA activates alternatively with t1 and t2 activates for total cycle time (t1+t2)
Accuracy 0.02% from span negligible
Measurement error Temperature drift
Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption
230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 2 VA
Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity
-10...65 °C 0...85 %RH -10...70 °C 0...95 %RH, non-condensing
Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals
plastic in 45x45 mm panel cut-out or on 35 mm DIN rail socket UNDECAL (5) 48x48(front)x95 mm 103 mm (w/ socket) max. 250 g IP54 / IP20
(1)
One-shut cycle mode; cyclic mode (repeated cycle); one-shut cycle mode (t2 - total cycle time); cyclic mode (t2 - total cycle time) Relay K1 action after start; relay K2 action in active period; inactive state of K1 and K2; specifies period adjusted by BCD; restart during action; automatic start at power-on Ask for availability! (4) ONLY with isolated power supply! (5) Ordered separately (see 'Accessories') (2)
Ordering code
CT03 - G1.G5G5
Code Feature or option
(6)
Code values
G1
Power supply
A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
G5
Relay output
X - none (6), C - relay NO/NC, D - SSR (3), E - open collector NPN (4), J - for external SSR, M - isolated MOS gate
At least one relay must be ordered!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(3)
timers and counters Analog Timer with Display CT04 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
Low cost 4-digit LED display Time setting via push-wheel switch Improved precision ON and OFF delay Controls main and auxiliary relay 48x48 mm DIN-sized front panel Panel or rail mounting
With its 48x48 mm DIN-sized front panel, the CT04 timer is especially suitable for building in machines and installations where compact size is important. A 4-digit LED display indicates the current time, and the delay is set by push-on wheels (BCD coders), which greatly simplifies the setting and improves accuracy. Equipped with 2 relay outputs – main and auxiliary relay – CT04 can be used for timing control (switching on and off) of various electrical actuators. The main relay is time operated, and the auxiliary relay is activated at power-on or simultaneously with the main relay. In spite of its simple design and low price, CT04 has all main functions of a modern electronic timer and can be widely used in industry and consumer goods.
Technical specifications Times and modes
Power supply
Range Time unit Mode of operation Timing start
Outputs Relay electromechanical Solid state relay (1) MOS gate Transistor gate (2) Output for external SSR Main (timer) relay Auxiliary relay
0.0...99.9 or 0...999 seconds or minutes on-delay or off-delay at power-on (up to 2 - main and auxiliary) 5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated open collector, 40mA/40V 12/24 V, 30 mA time operated activates at power-on or copies main relay
Accuracy 0.05% from span insignificant
Measurement error Temperature drift
Indication and controls 4 LED indicators, 9 mm 2 LEDs for relay state and time unit for easy time setting
Digital display LEDs Push-wheel switch
Mains supply voltage Isolated low voltage Non-isolated low voltage Consumption
230 VAC or 115 VAC 24 VDC 24 VAC or 24 VDC max. 2 VA
Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity
-10...65 °C 0...85 %RH -20...65 °C 0...95 %RH, non-condensing
Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals
plastic in 45x45 mm panel cut-out or on 35 mm DIN rail socket (3) OCTAL or UNDECAL (4) 48x48(front)x95 mm max. 103 mm (w/ socket) max. 250 g IP40 / IP20
(1)
Ask for availability! ONLY with isolated power supply! Ordered separately (see 'Accessories') (4) ONLY with auxiliary relay (2)
(3)
CT04 - G1.G5G5.G6.G8
Code Feature or option
(5)
Code values
Power supply
A - 230 VAC, B - 115 VAC, D - 24 VDC, E - 24 VAC, Q - 24 VDC, isolated
G5
Relay output
X - none (5), C - relay NO/NC, D - SSR (1), E - open collector NPN (2), J - for external SSR, M - isolated MOS gate
G6
Time range
LS - 0...99.9 s, HS - 0...999 s, LM - 0...99.9 min, HM - 0...999 min
G8
Operating mode
D - delay ON, E - delay OFF
G1
A main relay MUST be installed!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
timers and counters Budget DIN-rail Digital Timer CT05 ♦ ♦ ♦ ♦ ♦ ♦
For low-cost applications Slim size 3 operating modes Up to 100 hour time delay Long relay life Easy setup and programming
CT05 is a DIN-rail mountable programmable time-delay relay designed for time sequence control of electrical actuators. The time delay can be adjusted from 0.1 s up to 100 h via a rotary switch and a trimming potentiometer on the front panel and the timing starts at power-on. Different modes of operation – on-delay, off-delay, and cyclical output – can be selected with the rotary micro switch. The timer is equipped with 1 relay output as well as a multi-function LED indicating power supply, relay, and failure status, timing and program modes. CT05 is very easy to set, program, and operate, and yet has all the main functions of a modern programmable timer.
Technical specifications Times and modes
Power supply
Ranges
0.1...1 s, 1...10 s, 0.1...1 min, 1...10 min, 0.1...1 h, 1...10 h, 10...100 h programmable (see table below)
Modes of operation
Output
Non-isolated SMPS voltage Non-isolated low voltage Consumption
24…230 VAC/DC 24 VAC/DC ± 10% max. 2 VA
Operating conditions
Output type Contact form and ratings Contact life cycles Initiate time Reset time
electromechanical relay NO/NC (SPDT), max. 5 A, max. 250 V 106 ≤ 350 ms ≤ 350 ms
Accuracy
Operating temperature Operating humidity Storage temperature Storage humidity
-20...65 °C 0...85 %RH -30...80 °C 0...95 %RH, non-condensing
Design and materials
Time accuracy Time repeatability
better than 0.5% of span better than 0.1% of span
Indication and controls LEDs Trimming potentiometer Rotary switch
LED for power ON, mode, and state for time adjustment and mode selection for range and mode selection
Mode
Case material Mounting Wiring Dimensions Weight Protection class
plastic on 35 mm DIN rail screw terminals 18x90x58 mm max. 70 g IP20
Delay ON
Cyclic delay ON
Pulsed delay ON
Delay OFF
Cyclic delay OFF
Pulsed delay OFF
U - power supply voltage R - relay output T - time delay
Ordering code
CT05 - G1
Code Feature or option G1
Power supply
Code values K - 24…230 V, non-isolated, P - 24 VAC/DC, non-isolated
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
LEGEND:
timers and counters 2-channel Programmable Timer CT12 ♦ ♦ ♦ ♦ ♦ ♦ ♦
2 programmable timers in one case Up to 2 freely programmable relay outputs Up to 10 programmable periods per channel 2 programs or 1 longer one 4-digit LED display Start from external input or from keyboard Maximum time per period 9999 minutes
CT12 is a programmable device for timing control incorporating 2 independent timers in one case. Two relay outputs (one per channel) control electrical actuators by switching them on and off. A time sequence that may consist of up to 10 ON or OFF periods, each with different duration, may be programmed for each output (channel). The device may be used as a single channel timer with up to 20 period time sequence. After a start command from the featured external input or the front-panel keyboard, the time sequence may be run once or repeated endlessly. A 4-digit digital display indicates current time and – during programming – parameter values, and the keyboard enables setting of all modes and parameters of time sequence. The CT12 timer is easy to program and – with its rich set of features – widely applicable.
Technical specifications Inputs
Indication and controls
Passive contact input Active signal input External 'Start/Stop' Input setting (2)
NO contacts voltage, max. 40 VDC starts and stops time sequence (1) programmable
Times and modes
Keyboard
4 LED indicators, 10 mm 2 LEDs for output state, 2 LEDs for indicated channel 4 membrane keys
Power supply
Time sequences Time periods Period duration range Time setting Output state setting Mode selection Measurement unit selection
Outputs
Digital display LEDs
(3)
Relay electromechanical Solid state relay MOS gate Transistor gate (4) Output for external SSR Relay function
1 per channel up to 10 per channel or 20 in single-channel mode 0.01 s...9999 min programmable for each period programmable for each period programmable programmable (up to 2 relay outputs) 5A/250V w/ NO/NC contact 1A/250 VAC 0.1A/60V, optically isolated open collector, 40mA/40V 12/24 V, 30 mA ON and OFF, acc. to time sequence
Accuracy 0.7% insignificant
Measurement error Temperature drift
Mains supply voltage (5) SMPS voltage Isolated low voltage Non-isolated low voltage Consumption
230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC (5) 12…24 VAC/DC max. 3 VA
Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity
-10...65 °C 0...85 %RH -20...65 °C 0...95 %RH, non-condensing
Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals Increased front IP (option) (5)
plastic in 93x45 mm panel cut-out screw terminals 96x48(front)x125 mm 120 mm max. 350 g IP54 / IP20 IP65
(1)
Time sequence start and stop may be initiated through external input or keyboard. Select the active front of external signal When only the single-channel mode will be used (20-period time sequence), only one (the first) relay may be ordered. (4) ONLY with isolated power supply! (5) Ask for availability! (2)
Ordering code
CT12 - G1.G5G5 - #1
Code Feature or option
Code values
G1
Power supply
A - 230 VAC (5), B - 115 VAC (5), C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC (5)
G5
Relay output (3)
X - none, C - relay NO/NC, D - SSR, E - open collector NPN (4), J - for external SSR, M - isolated MOS gate
#1
Increased front protection
X - none, P - IP65 front protection (5)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(3)
timers and counters Universal Programmable Counter CT34 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
Available as totalizer, R.P.M. meter, and combined One or two 6-digit LED displays Pulse- and analog-input versions Programmable divider and multiplier Pulse counting and batch counting Additional inputs CLEAR, GATE, and DIRECTION 6 user-selectable operating modes plus dosing mode Up to 2 programmable relay outputs Optional optical input isolation up to 1500 VAC RS485 serial interface available
CT34 is a sophisticated new-generation counter equipped with a 6-digit display, which can hold up to 999999 count units or batches, and may have up to 2 programmable relay outputs and an analog output for alarm signaling or process controlling. СТ34 is available as a counter, as an R.P.M. meter, and as a combination of both. As a counter, this model allows programming of 7 different counting and output-relay-action modes (including dosing mode) as well as counting pulses or pulse batches. The R.P.M.-meter variant has 6 operating modes. Besides its counting input, CT34 has 3 additional inputs – CLEAR, GATE, and DIRECTION – and a user-programmable software input filter. Other useful features include fraction number coefficient prescaler and programmable actual and displayed counting directions. With its various features and flexible programmable internal structure, the CT34 counter is a widely applicable device.
Technical specifications Counting input: - pulse, w/ programmable active front - analog, programmable (1,2) Input CLEAR Input GATE Input DIRECTION (3) Maximum input frequency Input filter Prescaler coefficients Input isolation (option)
Indication and controls mechanical contact (NO) or electronic (from PNP / NPN sensor) 0(4)...20 mA or 0...5(10) V resets counter to '0' (4 functions) enables pulse counting changes counting direction 5 kHz for suppression of contact bouncing 1...9999, multiplying and dividing optical, 1500 VAC
Modes Operating modes Counting modes Counting range Programming
Outputs Relay electromechanical (5) Solid state relay MOS gate Transistor gate (6) Output for external SSR Relay action Output pulse duration (8) Analog output Serial interface (1)
7 (incl. dosing mode) pulse counting and batch counting 0...2147483647 through keyboard (up to 2 outputs) 5A/250V w/ NO/NC (4) contact 1A/250VAC 0.1A/60V, optically isolated open collector, 40mA/40V 5…24 V, 30 mA according to the mode (7) 0.1...99.9 s, programmable 0(4)…20 mA or 0…10 V, isolated RS485, isolated
PV display (1) SP display LEDs Keyboard
6 LED indicators, 9 mm 6 LED indicators, 9 mm 2 LEDs for output state 4 membrane keys
Power supply Mains supply voltage (1) SMPS voltage Isolated low voltage Non-isolated low voltage Consumption
230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC (5) or 24 VAC (1) 12…24 VAC/DC max. 6 VA
Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity
Design and materials Dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals)
'L'
-10...65 °C 0...85 %RH -20...65 °C 0...95 %RH, non-condensing 'S' 'H'
76x35x62 panel 71x29 56 180 IP54/20 IP65 plastic screw
48x48x110 panel 45x45 100 200 IP54/20 plastic screw
96x48x107 panel 90x42 98 280 IP54/20 IP65 plastic plug-in
(1)
Not available for case 'L' Available ONLY for variant 'CR'! Only with pulse input type! (4) NO for case 'L' (5) Ask for availability! (6) ONLY with isolated power supply! (7) st nd In case of variant 'CR' with pulse input, if not additionally specified, 1 relay is linked to counter and 2 – to R.P.M. meter. st nd With analog input, 1 relay is firmly linked to counter and 2 relay is user programmable. (8) nd Instead of 2 relay (_G5)! (9) Not available for case 'S' (2)
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
COMECO reserves the right of changing specifications without prior notice!
Inputs
timers and counters Ordering code
CT34 - G0.G1.G3.G5G5.G9'9".G11 - #1.#2
Code Feature or option
Code values
Variant
C - totalizing counter, R - R.P.M. meter, CR - combined
G0
Case (front size)
H - 96x48 mm, S - 48x48 mm, L - 72x36 mm
G1
Power supply
A - 230 VAC , B - 115 VAC , C - 90…250 V, (5) (1) P - 12…24 V, non-isolated, Q - 12…24 V, isolated , R - 24 VAC
G3
Counting input
P - pulse, A - analog
G5
Relay output
G9' G9"
(1)
(1)
(1,2)
, D - SSR
(5)
Serial interface
X - none, B - RS485
Protocol
A - ASCII, C - ASCII for " PolyMonitor"
(5)
(7)
(8)
X - none, C - relay NO/NC M - isolated MOS gate
(4)
, E - open collector NPN
(6)
, J - for external SSR,
(1)
Analog output
X - none, E - 0…20 mA, F - 4…20 mA, K - 0…10 V
#1
Input isolation
X - none, I - input isolation
#2
Increased front protection
X - none, P - IP65 front protection (9)
COMECO reserves the right of changing specifications without prior notice!
G11
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
timers and counters 2-channel Flow-rate Counter CT34SB ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
Accepts pulse signals from 2 flow-meters Fully-programmable math block Two 6-digit LED displays Indicates current flows, math result, total counts Programmable relay output Sensor supply voltage 5...24 VDC Programmable input filtering 96x48 front size panel mounting
CT34SB is a specialized 2-channel fully programmable flow-rate totalizing counter. The instrument is especially designed to measure pulse signals from 2 different flow-meters according to the functional block-diagram below:
Counter software allows a convenient programmable scaling of both measured flow signals and applying various calculations on both flow rates. CT34SB is equipped with two 6-digit LED displays indicating current flow-rates, mathematically calculated values as well as accumulated total counts. The counter has also an optional relay output for generating impulse when certain total value is reached (dosing function).
Technical specifications Power supply
Counting inputs Input type Active front Maximum input frequency Input filter Scaling coefficients Totalizer range Math functions
2 pulse inputs (A and B) contact (NO) or PNP/NPN sensor programmable 5 kHz programmable low-pass filter scale factor and time-base up to 5000000 counts A-B, A+B, A*B, A/B, A/(A+B)
Indication and controls Digital displays Display function (link) LEDs Keyboard
2 x 6 LED indicators, 9 mm Rate A(B), Math result, Total 2 LEDs for output state 3 membrane keys
Output Relay electromechanical Solid state relay (1) MOS gate Transistor gate (2) Output for external SSR Relay action Output pulse duration (1) (2)
5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated open collector, 40mA/40V 5…24 V, 30 mA totalizer set-point (dosing function) 0.02...1.2 s, programmable
Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption
230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 6 VA
Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity
-10...65 °C 0...85 %RH -20...65 °C 0...95 %RH, non-condensing
Design and materials Dimensions Mounting Mounting depth Maximum weight Protection, front/terminals Increased front IP (option) Case material Wiring
96x48x107 mm panel cutout 90x42 mm 98 mm 280 g IP54/20 IP65 plastic plug-in terminals
Ask for availability! ONLY with isolated power supply!
Ordering code
CT34SB - G1.G5 - #1
Code Feature or option
Code values
G1
Power supply
A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC
G5
Relay output
X - none, C - relay NO/NC, D - SSR (1), E - open collector NPN (2), J - for external SSR, M - isolated MOS gate
#1
Increased front protection
X - none, P - IP65 front protection
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
COMECO reserves the right of changing specifications without prior notice!
Inputs
timers and counters Programmable Counter CT38 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
Low cost 4-digit LED display for up to 9999 units Easy programming Universal optically isolated counting input Additional RESET input available 6 modes of operation of the counter and the relay output Programmable input multiplying coefficient 48x48 mm DIN-sized front panel
CT38 is a single-channel programmable counter with simplified programming. The device has a 4-digit display and can count up to 9999 input pulses. CT38 may work as up or down counter and has a relay output for switching on and off electrical actuators. Relay output action at reaching the preset counter value is user programmable. CT38 offers 4 counting modes and 2 output action modes. It features optical input isolation, and, optionally, an additional RESET input. The universal input allows connection of both mechanical contacts and electronic sensors. A software preliminary multiplying coefficient enables counting several units at each pulse. With its compact size, easy programming, and attractive price, the CT38 counter is widely used in machine manufacturing and various other areas.
Technical specifications Inputs
Indication and controls
Counting input - type selection Input RESET Maximum input frequency Input filter (fixed) Prescaling multiplying coefficient Input isolation
mechanical contact (NO) or electronic (from PNP / NPN sensor) not needed (automatic) NO contact; resets counter to 0 500 Hz for input contact bouncing 1...999, programmable optical, 750 VAC
Modes
Digital display LEDs Keyboard
4 LED indicators, 10 mm 3 LEDs for output and modes 6 membrane keys
Power supply Mains supply voltage Isolated low voltage Non-isolated low voltage Consumption
230 VAC or 115 VAC 12 VDC 12 VDC or 12 VAC max. 2 VA
Operating conditions 4 (1) 2 (2) 0...9999 through keyboard (up to 2 relay outputs)
Counting modes Output action modes Counting range Programming
Outputs Relay electromechanical Solid state relay (3) MOS gate Transistor gate (4) Output for external SSR Relay action Output pulse duration
5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated open collector, 40mA/40V 12 V, 30 mA according to the mode 0.1...9.9 s, programmable
Operating temperature Operating humidity Storage temperature Storage humidity
-10...65 °C 0...85 %RH -20...65 °C 0...95 %RH, non-condensing
Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals
plastic in 45x45 mm panel cut-out or on 35 mm DIN rail socket (5) OCTAL or UNDECAL (6) 48x48(front)x92 mm max. 103 mm (w/ socket) max. 250 g IP40 / IP20
(1)
Counting up or down; counting with or without automatic reset at reaching preset counter value Output activates and retains the new state with counter reaching preset value; output activates for a short time with counter reaching preset value Ask for availability! (4) ONLY with isolated power supply! (5) Ordered separately (see 'Accessories') (6) ONLY with RESET input (G7="A") (2)
Ordering code
CT38 - G1.G5.G7
Code Feature or option
Code values
G1
Power supply
A - 230 VAC, B - 115 VAC, D - 12 VDC, E - 12 VAC, Q - 12 VDC, isolated
G5
Relay output
C - relay NO/NC, D - SSR (3), E - open collector NPN (4), J - for external SSR, M - isolated MOS gate
G7
RESET input
X - none, A - contact
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(3)
timers and counters Battery-powered Counter CT36 ♦ ♦ ♦ ♦ ♦ ♦
Low cost 8-digit totalizing LCD display 7-year lifetime without battery replacement 1 to 1000 cps selectable counting speed Front and rear-panel RESET 48x24 mm DIN-sized front panel
CT36 is a simple and low-cost battery-powered electronic counter, enclosed in a small plastic box with 48x24 mm front size. Equipped with a 8-digit LCD display, CT36 can count up to 99999999 units. It has 2 inputs counting input with counting speed up to 1000 cps and a RESET input. Both inputs can accept input signals from mechanical or electronic switches. A RESET button on the front panel is also available. The device may be equipped with micros-witches allowing front frequency selection as well as front reset key enabling. CT36 is powered by an incorporated lithium battery that has approximately 7 years of life cycle. Thanks to its small size and longlife battery operation, CT36 can be very useful for many applications requiring independent supply and small mounting dimensions such as integration in water meters, gas meters, etc.
Technical specifications Power supply
Inputs Counting input - active front - residual voltage Input RESET - function - reset pulse Maximum input frequency ON-sense OFF-sense
mechanical contact (NO) or electronic (NPN/PNP/MOS-gate sensor) rising ≤ 0.5 VDC NO contact or electronic sensor resets counter to 0 min. 20 ms 1 Hz, 30 Hz, 1000 Hz, fixed or selectable < 10 kΩ > 750 kΩ
Mode
Indication and controls 8 LCD indicators, 9 mm RESET left: select input frequency, right: front reset enable/disable
Digital display Front push button Side micro-switches
Ordering code
Operating conditions Ambient temperature Ambient humidity Storage temperature Vibration (malfunction) Shock (malfunction) Dielectric strength Insulation resistance
-10...55 °C, non-freezing 35...85 %RH -25...65 °C, non-freezing 0.3 mm at 10…55 Hz for 10 min 3 x 100 m/s2 (≈ 10 G) 2000 VAC for 1 min > 100 MΩ at 500 VDC
Case material Mounting Wiring Dimensions Mounting depth Weight Protection class
plastic in 45x22 mm panel cut-out screw terminals 48x24(front)x58 mm 54 mm max. 60 g IP20
CT36 - G4
Code Feature or option
Code values
Variant
U - w/ selectable input frequency, A - w/ 1 Hz input, B - w/ 30 Hz input, C - w/ 1 kHz input
Reset
D - from input RESET, C - from front-panel button, DC - from both sources
COMECO reserves the right of changing specifications without prior notice!
G4
3 V from lithium battery CR2477 ≈ 7 years (at 20 °C)
Design and materials up counting 0...99999999
Counting mode Counting range
Supply voltage Battery life
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
handheld devices 2-channel Programmable Thermometer H5700 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
Good accuracy at low consumption Operates with Pt1000 and 3 types of thermocouples Universal input available Measures temperature from up to 2 sensors 4-digit LCD display with mode indication Programmable auto power-off function Battery voltage management Readings in Celsius or Fahrenheit Sensor failure control
H5700 is a handheld 2-channel microprocessor-based device for measurement of temperature in 1 or 2 points by the means of Pt1000 sensors or thermocouples type "J", "K", or "S". The device has a 4-digit display providing a resolution of 0.1 °C within the -99.9...999.9 °C range. Two modes of operation – measurement of 1 temperature and measurement of 2 temperatures and temperature difference – are available. H5700 is programmed and controlled through a folio-type keyboard providing high degree of environmental protection. The device is offered with 2 alkaline or rechargeable 1.5 V AA batteries and features a special automatic-battery-control function. The numerous features of H5700, its high accuracy, and low consumption make it a widely applicable measurement instrument.
Technical specifications Inputs
(up to 2 inputs) -100.0...660.0 °C -100.0...1200 (999.9) °C -100.0...1300 (999.9) °C 0.0...1700 (999.9) °C
Pt1000 (w=1.385) Thermocouple "J" Thermocouple "K" Thermocouple "S"
Indication and controls 4-digit LCD, 13 mm 3 membrane keys
Digital display Keyboard
Accuracy
Power supply Supply voltage Operating consumption Stand-by consumption Auto-power-off time
3 V from 2 batteries AA 1.5 V (1) less than 3 mA less than 5 µA 0...30 min, programmable
0.1% (0.3% for T/C input) from span negligible ± 1 °C 0.01% from span for 1 °C 0.05% from span for 1 V
Case material Probe connection Dimensions Weight Protection, case/socket
plastic 4-pin snap-in connector ø8, type 'C3' 65x118x22 mm max. 110 g (w/ batteries) IP44 / IP20
H5700 - G1.G6'6"G6'6"
Code Feature or option
Code values
G1
Power supply
X - none (2), G - long-life batteries, H - rechargeable batteries
G6'6"
Input
X - none (3), A - programmable, BG - Pt1000, CJ - thermocouple "J", CK - thermocouple "K", CS - thermocouple "S"
The device is supplied without batteries. Only the second input can be cancelled.
COMECO reserves the right of changing specifications without prior notice!
(3)
-10...65 °C 0...85 %RH
Battery charger can be ordered separately (see 'Accessories').
Ordering code
(2)
Operating temperature Operating humidity
Design and materials
Measurement error Non-linearity Cold junction compensation Temperature drift Supply-voltage variation influence (1)
Operating conditions
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
handheld devices Programmable Hygro-/Thermometer H5800 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
Good accuracy at low consumption Operates with COMECO humidity handheld probes Humidity and temperature measurement Automatic temperature compensation of the RH probe 4-digit LCD display with mode indication Programmable auto power-off function Battery voltage management Readings in percentage, degrees Celsius or Fahrenheit
H5800 is a handheld microprocessor-based device for relative-humidity measurement in air and non-aggressive gases, designed to operate with COMECO’s RH probes. With the help of a Pt1000 sensor build in the RH probe, H5800 compensates probe temperature drift and indicates medium temperature. The device is equipped with a 4-digit display providing a resolution of 0.1. Two modes of operation – measurement of relative humidity and measurement of medium temperature in degrees Celsius or Fahrenheit – are available. Dew-point, absolute humidity, mixing ratio, and enthalpy can also be measured through calculation. H5800 is programmed and controlled through a folio-type keyboard providing high degree of environmental protection. The device is offered with 2 alkaline or rechargeable 1.5 V AA batteries and features a special automatic-battery-control function. The numerous features of H5800, along with its high accuracy and low consumption, make it a widely applicable measurement instrument.
Technical specifications Inputs
Operating conditions
RH input - range Temperature input - range
0…100 mV 0…100 %RH Pt1000 (w=1.385) -20...150 °C (-4...302 °F)
Indication and controls 4-digit LCD, 13 mm 3 membrane keys
Digital display Keyboard
Accuracy
Power supply Supply voltage Operating consumption Stand-by consumption Auto-power-off time
3 V from 2 batteries AA 1.5 V (1) less than 8 mA less than 1 µA 0...30 min, programmable
0.1% from span 0.1% from span negligible 0.01% from span for 1 °C 0.2% from span for 1 V 0.1% from span for 1 V
Case material Probe connection Dimensions Weight Protection, case/socket
plastic 4-pin snap-in connector ø8, type 'C3' 65x118x22 mm max. 110 g (w/ batteries) IP44 / IP40
Battery charger can be ordered separately (see 'Accessories').
Ordering code
H5800 - G1
Code Feature or option G1
Power supply
Code values X - none (2), G - long-life batteries, H - rechargeable batteries
The device is supplied without batteries.
COMECO reserves the right of changing specifications without prior notice!
(2)
-10...65 °C 0...85 %RH
Design and materials
RH measurement error Temperature measurement error Non-linearity Temperature drift Supply-voltage influence for RH Supply-voltage influence for T (1)
Operating temperature Operating humidity
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
handheld devices Hygro-/Thermometer for Solids H5850 ♦ ♦ ♦ ♦ ♦ ♦ ♦
Good accuracy at low consumption Operates with RHP humidity probes Moisture and temperature measurement 4-digit LCD display with mode indication Programmable auto power-off function Battery voltage management Readings in percentage, degrees Celsius or Fahrenheit
H5850 is a handheld microprocessor-based device for humidity measurement of solids and bulk materials, designed to operate with COMECO’s RH probe model RHP. With the help of a Pt1000 sensor build in the RH probe, H5850 indicates the medium temperature too. The device is equipped with a 4-digit display providing a resolution of 0.1. Three modes of operation – measurement of moisture content, measurement of relative humidity, and measurement of medium temperature in degrees Celsius or Fahrenheit – are available. H5850 can be programmed and controlled through a folio-type keyboard providing high degree of environmental protection. The device is offered with 2 alkaline or rechargeable 1.5 V AA batteries and features a special automatic-batterycontrol function. The numerous features of H5850, along with its high accuracy and low consumption, make it a useful instrument for bulk-material moisture measurement.
Technical specifications Inputs
Operating conditions
Humidity input - moisture-content range - relative-humidity range Temperature input - range
from RHP probe 0…300 % 0…75 % Pt1000 (w=1.385) -20...150 °C (-4...302 °F)
Indication and controls 4-digit LCD, 13 mm 3 membrane keys
Digital display Keyboard
Accuracy
Power supply Supply voltage Operating consumption Stand-by consumption Auto-power-off time
3 V from 2 batteries AA 1.5 V (1) less than 8 mA less than 1 µA 0...30 min, programmable
0.2% from span 0.1% from span negligible 0.01% from span for 1 °C 0.2% from span for 1 V 0.1% from span for 1 V
Case material Probe connection Dimensions Weight Protection, case/socket
plastic 4-pin snap-in connector ø8, type 'C3' 65x118x22 mm max. 110 g (w/ batteries) IP44 / IP20
Battery charger can be ordered separately (see 'Accessories').
Ordering code
H5850 - G1
Code Feature or option G1
Power supply
Code values X - none (2), G - long-life batteries, H - rechargeable batteries
The device is supplied without batteries.
COMECO reserves the right of changing specifications without prior notice!
(2)
-10...65 °C 0...85 %RH
Design and materials
Humidity measurement error Temperature measurement error Non-linearity Temperature drift Supply-voltage influence for humidity Supply-voltage influence for T (1)
Operating temperature Operating humidity
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
handheld devices Handheld Moisture-content Meter H6300 ♦ ♦ ♦ ♦ ♦ ♦ ♦
Non-contact measurement of wood and concrete samples Modern electromagnetic measurement principle Measurement depth 1...7 cm Entirely eliminates temperature influence Integral moisture-content value measurement Very fast measurement Low price
H6300 by COMECO is designed to measure moisture content of wood or concrete samples, employing an electromagnetic measurement principle. With the help of a sensor detecting variations of electromagnetic field within sample, the device measures moisture content even without an electrical contact with the sample. To perform a measurement, simply place the moisture detector on even sample surface. MOISTURE DETECTOR
A correction table for measurement correction for various types of wood and concrete is supplied with the moisture meter. H6300 may be used for other similar materials if their specific weight when completely dry is known. The moisture detector is equipped with a 16-dot LED display for exact reading of moisture in 1% steps. H6300 is offered with an alkaline or rechargeable 9 V battery. Battery charger is available as accessory. An exceptionally lightweight and compact device, H6300 is especially suited for measurement of thin samples as well as for fast and frequent measurements.
Technical specifications Input
Indication and controls
Input type Measurement range Temperature range Sample material type Temperature influence Surface-moisture interference Static-charge interference
electromagnetic 4...22% moisture content -20...100 °C up to 100 different types none insignificant insignificant
Accuracy ± 1% 0.05% from span for 1 °C 0.05% from span for 1 V fixed manual, via correction table
Material Dimensions Weight Protection class
Operating temperature Operating humidity
Battery charger can be ordered separately (see 'Accessories').
H6300 - G1
Code Feature or option G1 (3)
Supply voltage Consumption Battery state control
9 V from battery 6F22 (1) less than 3 mA automatic
plastic 65x112x22 mm max. 120 g IP44
Operating conditions 2 x 7 cm 13 mm 1s
Minimum sample area Minimum sample thickness Measurement time
(2)
Power supply
Code values
Variant
W - for wood, C - for concrete (2)
Power supply
X - none (3), G - long-life battery, H - rechargeable battery
Ask for availability! The device is supplied without battery.
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
-10...65 °C 0...85 %RH
COMECO reserves the right of changing specifications without prior notice!
Measurement requirements
Ordering code
16 LED dots 1 membrane key
Design and materials
Measurement error Temperature drift Supply-voltage variation influence Factory calibration Correction for other material
(1)
Bargraph display Keyboard
actuators and heaters Low-cost 1-phase AC Relay SSRP ♦ ♦ ♦ ♦ ♦ ♦
Zero-cross output switching Up to 275 VAC operating voltage 10 A, 16 A, 25 A, or 40 A switching RMS current 4 input ranges 4000 V input / output insulation Heatsinks available
The SSRP solid state relay is a zero-cross operating electronic module designed to switch single-phase AC power loads. Thanks to its higher switching frequency and practically complete absence of electromagnetic interference, the SSR module is a non-contact and convenient substitute of power contact relays. The life and reliability of the SSR module, compared to these of the contact relays, are much higher because there are no moving parts, noise, shocks, and vibration during the operation. SSRP can switch active or small inductive loads from 10 to 40 A at power voltage up to 275 VAC. The control input is optically isolated from the output and accepts AC or DC voltage signals. An operating LED indicates ON/OFF device status. Heatsinks are available as accessory.
Technical specifications Input
General specifications
Control voltage Input current Turn-on / off voltage Reverse voltage protection
Output
(no connection with the input types!)
On-state current at proper heatsink (1) ≤ 10 Arms ≤ 16 Arms ≤ 25 Arms ≤ 40 Arms Minimum holding current 50 mA 80 mA 50 mA 80 mA Non-rep. surge current at t = 20 ms 160 A 400 A 100 A 250 A Maximum leakage current 2 mA 5 mA 1 mA 3 mA Critical rate of current rise dI/dt 50 A/μs 50 A/μs 50 A/μs 50 A/μs I2t value for fusing at t = 10 ms 78 A2s 78 A2s 78 A2s 78 A2s On-state voltage at rated current 1.6 Vrms 1.6 Vrms 1.6 Vrms 1.6 Vrms Critical off-state voltage rise dV/dt 400 V/μs 400 V/μs 500 V/μs 500 V/μs Operational frequency 45...65 Hz 45...65 Hz 45...65 Hz 45...65 Hz Thermal resistance (junction-case) 2.3 °C/W 2.1 °C/W 1.1 °C/W 1.2 °C/W (1) (2)
min. 24...max. 275 VACrms 600 Vp 700 Vp > 0.6 -20...65 °C -40...85 °C glass-filled plastic aluminum 4000 VACrms 2500 VACrms IP00 4 x M4 screws 2 x M4 screws MAC2 rail clamp (2) ø3, red ≈ 100 g
Operating AC voltage Rep. off-state peak voltage Non-rep. off-state peak voltage Power factor Operating temperature Storage temperature Case material Base plate (heatsink) material Input / output insulation Output / case insulation Protection class Wiring Mounting Rail mounting ON-indicating LED Weight
4...36 VDC 6...26 VAC/DC 115 VAC 230 VAC 6...12 mA 12 mA 5...12 mA 6 mA 3 VDC 4 VAC / 5 VDC 90 VAC 180 VAC -32 VDC -32 VDC -
We highly recommend using SSR at no more than 80% of maximum on-state current! Ordered separately (see 'Accessories') 22
30 12 FUSE
1
+
LOAD
2
4.3
24
80
48
Heatsink specifications Heatsink surface [cm2] / length [mm] (at 85 °C heatsink temperature) SSRP variant Current Æ Ambient temperature È
10
16
10 A
25
10 A
16 A
15 A
20 A
40 25 A
20 A
40 A
20 °C
72 / 62
60 / 62
214 / 62
134 / 62
287 / 62
499 / 62
237 / 62
607 / 62
1280 / 120
40 °C
150 / 62
124 / 62
445 / 62
278 / 62
601 / 62
1041 / 100
494 / 62
1275 / 120
2668 / 250
60 °C
485 / 62
400 / 62
1435 / 135
907 / 85
1924 / 180
Ordering code
1600 / 150
SSRP - G1
Code Feature or option
Code values
Variant
10, 16, 25, 40
G1
Input
A - 230 VAC, B - 115 VAC, D - 4…36 VDC, Е - 6…26 VAC/DC
Applicable accessories Code Description HS__
30 A
Heatsink (specify the length [mm] using the table above) w/ or w/o rail-mounting clamp (2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
3
80
AC VOLTAGE
61
CONTROL VOLTAGE
47
34
4
68 56
actuators and heaters 1-phase AC Relay for Inductive Loads SSRQ ♦ ♦ ♦ ♦ ♦ ♦
Designed for all types of loads up to 400 VAC Zero-cross output switching 10 A or 16 A switching RMS current 4 input ranges 4000 V input/output insulation Heatsinks available
The SSRQ solid state relay is a zero-cross operating electronic module designed to switch single-phase AC power loads. Since there are no moving parts, noise, shocks, and vibration during the operation, the life and reliability of the SSR module, compared to these of the contact relays, are much higher. Thanks to a snubberless™ triac, SSRQ can switch both active and inductive loads up to 16 A at power voltage up to 400 VAC. The control input is optically isolated from the output and accepts AC or DC voltage signals.
Technical specifications Input
General specifications
Control voltage Input current Turn-on/off voltage Reverse voltage protection
4...36 VDC 6...26 VAC/DC 115 VAC 230 VAC 6...12 mA 12 mA 5...12 mA 6 mA 3 VDC 4 VAC / 5 VDC 90 VAC 180 VAC -32 VDC -32 VDC (no connection with the input types!)
Output On-state current at proper heatsink (1) Minimum holding current Non-rep. surge current at t = 20 ms Maximum leakage current Critical rate of current rise dI/dt I2t value for fusing at t = 10 ms On-state voltage at rated current Critical off-state voltage rise dV/dt Operational frequency Thermal resistance (junction-case) (1) (2)
≤ 16 Arms 50 mA 160 A 2 mA 50 A/μs 78 A2s 1.6 Vrms 400 V/μs 45...65 Hz 2.1 °C/W
≤ 10 Arms 50 mA 100 A 1 mA 50 A/μs 78 A2s 1.6 Vrms 400 V/μs 45...65 Hz 2.3 °C/W
400 VACrms 24 VACrms 800 Vp 900 Vp -20...65 °C -40...85 °C glass-filled plastic aluminum 4000 VACrms 2500 VACrms IP00 4 x M4 screws 2 x M4 screws MAC2 rail clamp (2) ø3, red ≈ 100 g
Maximum operating AC voltage Minimum operating AC voltage Rep. off-state peak voltage Non-rep. off-state peak voltage Ambient temperature Storage temperature Case material Base plate (heatsink) material Input/output insulation Output/case insulation Protection class Wiring Mounting Rail mounting ON-indicating LED Weight
We highly recommend using SSR at no more than 80% of maximum on-state current! Ordered separately (see 'Accessories') 22
30 12 1
FUSE
+ 3
2
80
AC VOLTAGE
47
CONTROL VOLTAGE
61
34
4
68 56
LOAD
4.3
24
80
48
SSRQ variant
10
Current Æ Ambient temperature È
10 A
16 10 A
20 °C
72 / 62
60 / 62
214 / 62
40 °C
150 / 62
124 / 62
445 / 62
485 / 62
400 / 62
1435 / 135
60 °C
Ordering code
SSRQ - G1
Code Feature or option
Code values
Variant
10, 16
G1
Input
A - 230 VAC, B - 115 VAC, D - 4…36 VDC, Е - 6…26 VAC/DC
Applicable accessories Code Description HS__
16 A
Heatsink (specify the length [mm] using the table above) w/ or w/o rail-mounting clamp (2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Heatsink specifications Heatsink surface [cm2] / length [mm] (at 85 °C heatsink temperature)
actuators and heaters Low-cost DC Relay SSRD ♦ ♦ ♦ ♦ ♦ ♦
For DC loads Up to 300 VDC operating voltage Up to 40 A switching DC current 4 input ranges 4000 V input/output insulation Heatsinks available
The SSRD solid state relay is an electronic module designed to switch active or active/inductive DC power loads from 5 to 40 A at power voltage up to 300 VDC. Thanks to its higher switching frequency and practically complete absence of electromagnetic interference, the SSR module is a non-contact and convenient substitute of power contact relays. The life and reliability of the SSR module, compared to these of the contact relays, are much higher because there are no moving parts, noise, shocks, and vibration during the operation. The control input is optically isolated from the output and accepts AC or DC voltage signals. An operating LED indicates ON/OFF device status. Heatsinks are available as accessory.
Technical specifications Input
General specifications
Control voltage Input current Turn-on / off voltage Reverse voltage protection
4...36 VDC 6...26 VAC/DC 115 VAC 230 VAC 6...12 mA 12 mA 5...12 mA 6 mA 3 VDC 4 VAC / 5 VDC 90 VAC 180 VAC -32 VDC -32 VDC -
Output Operating DC voltage On-state current at proper heatsink (1) Non-repetitive pulse current Maximum leakage current On-state voltage at rated current Critical off-state voltage rise dV/dt Thermal resistance (junction-case) Power factor (1) (2)
-20...65 °C -40...85 °C glass-filled plastic aluminum 4000 VACrms 2500 VACrms IP00 4 x M4 screws 2 x M4 screws MAC2 rail clamp (2) ø3, red ≈ 100 g
Operating temperature Storage temperature Case material Base plate (heatsink) material Input / output insulation Output / case insulation Protection class Wiring Mounting Rail mounting ON-indicating LED Weight
(no connection with the input types!) 3...40 VDC 15...60 VDC 15...300 VDC ≤5A ≤ 20 A ≤ 40 A ≤ 15 A ≤ 130 A ≤ 160 A 10 μA 100 μA 100 μA 0.5 V 2V 1.3 V 400 V/μs 7 V/ns 15 V/ns 2.7 °C/W 1.6 °C/W 0.5 °C/W > 0.6 > 0.6 > 0.7
We highly recommend using SSR at no more than 80% of maximum on-state current! Ordered separately (see 'Accessories') 22
68 56
80
47
61
34
30 12
4.3
24
80
48
SSRD variant Current Æ
1
2
5A
20 A
30 A
20 °C
62
62
40 °C
62
62
60 °C
62
62
Ambient temperature È
Ordering code
3 40 A
10 A
16 A
62
62
62
62
62
62
120
62
62
120
120
250
62
120
250
SSRD - G1
Code Feature or option
Code values
Variant
1, 2, 3
G1
Input
A - 230 VAC, B - 115 VAC, D - 4…36 VDC, Е - 6…26 VAC/DC
Applicable accessories Code Description HS__
Heatsink (specify the length [mm] using the table above) w/ or w/o rail-mounting clamp (2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
20 A
COMECO reserves the right of changing specifications without prior notice!
Heatsink specifications Heatsink length [mm] (at 85 °C heatsink temperature)
actuators and heaters 1-phase Power AC Relay SSRT ♦ ♦ ♦ ♦ ♦ ♦
Zero-cross output operation Double thyristor output switch Up to 400 VAC operating voltage Up to 200 A switching RMS current 4 input ranges 4000 V input/output insulation
The SSRT solid state relay is a zero-cross operating electronic module designed to switch single-phase AC power loads. Thanks to its higher switching frequency and practically complete absence of electromagnetic interference, the SSR module is a non-contact and convenient substitute of power contact relays. The life and reliability of the SSR module, compared to these of the contact relays, are much higher because there are no moving parts, noise, shocks, and vibration during the operation. The SSRT electronic relays can switch active loads up to 200 Arms and inductive loads up to 95 Arms at power voltage up to 400 VAC. The control input is optically isolated from the output and accepts AC or DC voltage signals. An operating LED indicates ON/OFF device status.
Technical specifications Input
General specifications
Control voltage Input current Turn-on/off voltage Reverse voltage protection
4...36 VDC 6...26 VAC/DC 115 VAC 230 VAC 6...12 mA 12 mA 5...12 mA 6 mA 3 VDC 4 VAC / 5 VDC 90 VAC 180 VAC -32 VDC -32 VDC -
Output ≤ 200 Arms
AC switching current at proper heatsink (1) Minimum holding current Non-rep. surge current at t = 10 ms Maximum leakage current Critical rate of current rise dI/dt I2t value for fusing at t = 10 ms On-state voltage at rated current Critical off-state voltage rise dV/dt Operational frequency Thermal resistance (junction-case) (1) (2)
200 mA 1700 A 15 mA 150 A/μs 1125 A2s 1.6 Vrms 500 V/μs 45...65 Hz 0.14 °C/W
min. 24...max. 400 VACrms 1200 Vp 1300 Vp > 0.5 -20...65 °C -40...85 °C aluminum, 150 mm long 4000 VACrms 2500 VACrms IP00 screw terminals 3 x M5 screws for optimized cooling MAC2 rail clamp (2) ø3, red max. 350 g (w/ standard heatsink)
Operating AC voltage Rep. off-state peak voltage Non-rep. off-state peak voltage Power factor Operating temperature Storage temperature Standard heatsink Input/output insulation Output/case insulation Protection class Input wiring Output wiring Mounting Rail mounting ON-indicating LED Weight
We highly recommend using SSR at no more than 80% of maximum on-state current! Ordered separately (see 'Accessories')
FUSE 3
2
1
AC VOLTAGE
+ 4
LOAD
5
Heatsink specifications Heatsink surface [cm2] / length [mm] (at 105 °C heatsink temperature) Max. RMS current Æ Ambient temperature È 20 °C
(3)
40 A
60 A
80 A
100 A
430 / 150
1300 / 150
1900 / 180
3800 / 350
40 °C
720 / 150
2100 / 200
3300 / 310
60 °C
1500 / 150
4400 / 410
6900 / (3)
6500 /
120 A
(3)
13500 / (3)
Requires additional forced (fan) cooling!
Ordering code
SSRT - G1
Code Feature or option G1
Input
Code values A - 230 VAC, B - 115 VAC, D - 4…36 VDC, Е - 6…26 VAC/DC
Applicable accessories Code Description HS__
Heatsink (specify the length [mm] using the table above) w/ or w/o rail-mounting clamp (2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
5800 / (3) 10000 / (3) 20400 / (3)
COMECO reserves the right of changing specifications without prior notice!
CONTROL VOLTAGE
other control instrumentation Switch-mode Power Supply TC60P ♦ ♦ ♦ ♦
11-pin box for DIN-rail mounting Output power up to 5.5 W 90...250 VAC/DC SMPS Up to 2 independent stabilized output voltages
Technical specifications Input
Accuracy
Voltage Frequency Turn-on voltage Efficiency
90...250 V 47...440 Hz ≥ 85 VAC 76%, typical
Outputs
(up to 2 outputs) 1(2) x 24 VDC ≤ 0.23 A ≤ 5.5 W > 240 mV 4.0 kV 100 MΩ at 500 V
DC voltage Rated current Rated power AC voltage ripple Isolation voltage Isolation resistance
Protection 0.1 A 30 V ± 8% 105%
Front-panel fuse Over voltage Over load (1)
Operating conditions Operating temperature Operating humidity
-20...70 °C 0...85 %RH, non-condensing
Design and materials Case material Wiring Mounting Dimensions Weight Protection, front/terminals
plastic socket UNDECAL (1) in socket or on 35 mm DIN rail 35x78x91 mm max. 200 g IP44 / IP20
TC60P - G11G11
Code Feature or option G11
Output voltage (2)
Code values X - none (3), 24 - 24 VDC, Z - other (specify!)
Output supply voltages must be identical. At least one output must be ordered!
COMECO reserves the right of changing specifications without prior notice!
(3)
< ± 1.0% < ± 0.5% < ± 0.5% < 0.03% for 1 °C
Ordered separately (see Accessories)
Ordering code
(2)
Voltage tolerance Line regulation Load regulation Temperature drift
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
other control instrumentation Interface Adapter IA100 ♦ ♦ ♦ ♦ ♦
Universal RS485 to RS232 converter Designed for all COMECO devices equipped with RS485 Data acquisition from up to 32 net devices Suitable for COMECO "PolyMonitor" software Low cost
The IA100 interface adapter is a simple electronic device, designed to support the "PolyMonitor" multi-point data-acquisition software applicable for configuration and data collecting from a network of various COMECO control devices with RS485 interface and net addresses. IA100 supports up to 32 devices, connected into a RS485 net as well as the RS232 communication with PC or operating station. The information collected during the data-acquisition process can be stored, viewed, printed, and further processed through the "PolyMonitor" program or via customer-developed PC software based on the free communication protocols of the COMECO network devices.
Technical specifications 'Input' interface
Power supply
Interface type Function Supported net devices Format Baud rate
RS485 net control and data acquisition up to 32 8 (data) + 1 (stop), even parity max. 9600 bps
'Output' interface Interface type Function Format Baud rate
RS232 connection to PC 8 (data) + 1 (stop), none parity 9600 bps
Software "PolyMonitor" (1)
Data acquisition
Accessories custom made K6 (1)
RS485 input cable RS232 output cable
9 VAC/DC included max. 90 mA LED for power ON
Operating conditions Operating temperature Operating humidity
0...50 °C 0...80 %RH
Design and materials Case material Mounting RS232 connector RS485 connectors Dimensions Weight Protection, front/terminals
plastic desktop DB9, female RJ14, female and plug-in duplicating connector 72x150x31 mm max. 250 g IP54 / IP20
Ordered separately
Ordering code
IA100
COMECO reserves the right of changing specifications without prior notice!
(1)
Supply voltage Mains adapter (230 VAC) Consumption LEDs
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
other control instrumentation USB Interface Adapter IA250 ♦ ♦ ♦ ♦ ♦ ♦ ♦
Universal USB-to-Serial converter Optically isolated adapter Complies with USB 2.0 full speed standard Supports COMECO transmitters and RS485 devices Does not require additional power supply Suitable for "PolyMonitor" and "TraCon" software Small size and low cost
IA250 is a universal isolated interface adapter, designed to support interface connection between COMECO devices and PC or other USB devices. Its electronics is enclosed in a small-sized plastic box with IP54 front protection and equipped with USB-B and RJ25 interface connectors. Powered by the USB interface line, this plug-and-play device does not need any additional power supply. Two IA250 variants are available: - a variant for configuration and data collecting from a network of various COMECO control devices with RS485 interface and net addresses; - a variant for configuring COMECO transmitters via quasi-RS232 interface. IA250 is applicable to the "PolyMonitor" data-acquisition software and the transmitter-configuration program "TraCon", and may also be used with customer-developed PC software based on the free communication protocols of the COMECO devices.
Technical specifications 'Input' interface
Power supply
Network interface - supported net devices - function Transmitter interface - supported net devices - function Format Baud rate
RS485 up to 32 devices in up to 8 groups net control quasi RS232 COMECO smart transmitters configuration and data acquisition 8 (data) + 1 (stop), even parity max. 9600 bps
'Output' interface
5 VDC from USB line max. 100 mA
Indication 'Tx' LED 'Rx' LED
Accessories
(1)
Input cable Output cable
for data transmitting for data receiving variant 'N': K10U; variant 'T': K1U or K2U K8 (USB-B-to-USB-A standard)
Operating conditions
Interface type Function Format Speed Isolation
USB 2.0 full speed compatible connection to PC USB 2.0 specifications USB 2.0 specifications optical, 750 VAC
Software USB driver Transmitter configuration Data acquisition
FTDI standard USB driver "TraCon" v2.0 or higher, free "PolyMonitor" (1)
Operating temperature Operating humidity
0...50 °C 0...80 %RH
Design and materials Case material Mounting Input connector Output connector Dimensions Weight Protection class
plastic desktop RJ25, female USB-B, female 40x73x26 mm max. 60 g IP54
Ordered separately
Ordering code
IA250
Code Feature or option
Variant
Code values N - for RS485, T - for transmitters (quasi-RS232)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(1)
Supply voltage Consumption
other control instrumentation Interface Adapter / Datalogger IA300 InfoPrint ♦ ♦ ♦ ♦ ♦ ♦ ♦
RS485-to-RS232 converter Data acquisition from up to 32 net devices Thermal printer control for up to 8 process graphics Data-logging functions Easy configuration with "InfoPrint" software Convenient indication Attractive price-to-resources ratio
The IA300 interface adapter InfoPrint is an intelligent device designed especially to collect data from different COMECO instruments equipped with RS485 interface and net addresses. IA300 supports up to 32 devices, connected into a RS485 net and combined in 8 groups, thermal serial printer, and RS232 communication with PC. The information collected during the data-acquisition process can be used for: - printing up to 4 process charts on-line and up to 8 charts off-line; - data logging in the adapter memory and off-line downloading to PC for further processing. The IA300 electronics is equipped with 6 LED indicators (for power and communication modes) and convenient keyboard, all mounted in a plastic enclosure with IP54 front protection. All configuration procedures (including real-time clock) can be easily programmed with the "InfoPrint Command Interface" software. With its attractive price and enhanced capabilities, the IA300 interface adapter InfoPrint is a powerful solution for building multi-point monitoring systems.
Technical specifications 'Input' interface
Indication and controls
Interface type Function Supported net devices Format Baud rate
RS485 net control and data acquisition up to 32 8 (data) + 1 (stop), even parity 4800 bps
'Output' interface Interface type Function Format Baud rate
RS232 connection to PC or serial printer 8 (data) + 1 (stop), none parity 9600 bps
Data acquisition: - max. channels - max. device groups Graphics printing: - supported printer - max. graphics Data logging: - memory capacity - data downloading Configuration software
Operating conditions 0...50 °C 0...80 %RH
Operating temperature Operating humidity
Power supply up to 32 up to 8 serial thermal printer OT801 4 (on-line), 8 (off-line) 32 Kb to PC via RS232 "InfoPrint Command Interface", free
Accessories custom made K6 (1)
RS485 input cable RS232 output cable (1)
for power ON for communication to PC/printer OK for communication to PC/printer failed for RS485 stopped or memory full for data transmitting for data receiving 2 membrane keys
9 VAC/DC included max. 110 mA
Supply voltage Mains adapter (230 VAC) Consumption
Design and materials Case material Mounting RS232 connector RS485 connectors Dimensions Weight Protection, front/terminals
plastic desktop DB9, female RJ14, female and plug-in duplicating connector 72x150x31 mm max. 250 g IP54 / IP20
Ordered separately
Ordering code
IA300 - #1.#2
Code Feature or option
Code values
#1
Thermal printer
X - none, OT - thermal printer OT801 plus RS232 cable and 1 paper roll
#2
Additional paper rolls
X - none, 1…10 - number of additional paper rolls
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Functions and configuration
'On' LED 'RS 232 - Comm' LED 'Fail' LED 'Stop/Full' LED 'RS 484 - Tx' LED 'RS 484 - Rx' LED Keyboard
miscellaneous Software
Code
Software
Description
OS Devices Interface
Special Cable
Interface Adapter no
Notes
S1
"MiniSoft"
transmitter configuration and data-acquisition program
WIN MiniPAQ
RS232
yes
S2
"RStest"
simple program for RS232 or RS485 communication test
WIN all
RS232 RS485
depending on device connected
S3
"TraCon"
transmitter configuration and data-acquisition program
WIN TRB(I), TRY, RS232 TRZ, TRC
yes
no
free download from www.tracon.bz
S4
"Ipro"
transmitter configuration and data-acquisition program
WIN TRS (IPAQ)
RS232
yes
no
product of INOR
S5
"MePro"
HART Transmitter configuration and data-acquisition program
WIN MESO
HART
no
HART modem (communicator)
product of INOR
RS485
no
IA300
"InfoPrint"
configuration program for IA300 interface adapter / printer / datalogger
WIN IA300
S6 S7
"InfoMonitor"
data-acquisition program for TC800
WIN TC800
RS485
no
IA150
WIN LCSUPx (EchoTrack)
no
"EView"
viewing and configuration software for ultrasonic level transmitters w/ HART interface
HART
S8
HART modem (communicator)
S9
"PolyMonitor" program
universal data-acquisition
WIN all w/ RS485
RS485
no
IA100 IA250
S10
"UniConf"
universal configuration program
WIN all
RS232 RS485
S11
"Process"
single-process monitoring and recording program
WIN RT390
RS232
no
no
S12
"ThermLog"
temperature data-acquisition program for TC800
DOS TC800
RS485
no
IA150 (1)
S13
"ProfiSoft"
transmitter configuration and data-acquisition program
WIN TRP (ProfIPAQ)
RS232
yes
no
S14
"HartTemp"
HART Transmitter configuration and data-acquisition program
WIN TRH
HART
no
HART modem (communicator)
discontinued (1) product of NIVELCO
depending on device connected
product of Raycho Raykov product of INOR
Contact COMECO
COMECO reserves the right of changing specifications without prior notice!
(1)
product of INOR
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
miscellaneous Software
Code
Software
Description
OS Devices Interface
Special Cable
Interface Adapter no
Notes
S1
"MiniSoft"
transmitter configuration and data-acquisition program
WIN MiniPAQ
RS232
yes
S2
"RStest"
simple program for RS232 or RS485 communication test
WIN all
RS232 RS485
depending on device connected
S3
"TraCon"
transmitter configuration and data-acquisition program
WIN TRB(I), TRY, RS232 TRZ, TRC
yes
no
free download from www.tracon.bz
S4
"Ipro"
transmitter configuration and data-acquisition program
WIN TRS (IPAQ)
RS232
yes
no
product of INOR
S5
"MePro"
HART Transmitter configuration and data-acquisition program
WIN MESO
HART
no
HART modem (communicator)
product of INOR
RS485
no
IA300
"InfoPrint"
configuration program for IA300 interface adapter / printer / datalogger
WIN IA300
S6 S7
"InfoMonitor"
data-acquisition program for TC800
WIN TC800
RS485
no
IA150
WIN LCSUPx (EchoTrack)
no
"EView"
viewing and configuration software for ultrasonic level transmitters w/ HART interface
HART
S8
HART modem (communicator)
S9
"PolyMonitor" program
universal data-acquisition
WIN all w/ RS485
RS485
no
IA100 IA250
S10
"UniConf"
universal configuration program
WIN all
RS232 RS485
S11
"Process"
single-process monitoring and recording program
WIN RT390
RS232
no
no
S12
"ThermLog"
temperature data-acquisition program for TC800
DOS TC800
RS485
no
IA150 (1)
S13
"ProfiSoft"
transmitter configuration and data-acquisition program
WIN TRP (ProfIPAQ)
RS232
yes
no
S14
"HartTemp"
HART Transmitter configuration and data-acquisition program
WIN TRH
HART
no
HART modem (communicator)
discontinued (1) product of NIVELCO
depending on device connected
product of Raycho Raykov product of INOR
Contact COMECO
COMECO reserves the right of changing specifications without prior notice!
(1)
product of INOR
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
miscellaneous Software
Code
Software
Description
OS Devices Interface
Special Cable
Interface Adapter no
Notes
S1
"MiniSoft"
transmitter configuration and data-acquisition program
WIN MiniPAQ
RS232
yes
S2
"RStest"
simple program for RS232 or RS485 communication test
WIN all
RS232 RS485
depending on device connected
S3
"TraCon"
transmitter configuration and data-acquisition program
WIN TRB(I), TRY, RS232 TRZ, TRC
yes
no
free download from www.tracon.bz
S4
"Ipro"
transmitter configuration and data-acquisition program
WIN TRS (IPAQ)
RS232
yes
no
product of INOR
S5
"MePro"
HART Transmitter configuration and data-acquisition program
WIN MESO
HART
no
HART modem (communicator)
product of INOR
RS485
no
IA300
"InfoPrint"
configuration program for IA300 interface adapter / printer / datalogger
WIN IA300
S6 S7
"InfoMonitor"
data-acquisition program for TC800
WIN TC800
RS485
no
IA150
WIN LCSUPx (EchoTrack)
no
"EView"
viewing and configuration software for ultrasonic level transmitters w/ HART interface
HART
S8
HART modem (communicator)
S9
"PolyMonitor" program
universal data-acquisition
WIN all w/ RS485
RS485
no
IA100 IA250
S10
"UniConf"
universal configuration program
WIN all
RS232 RS485
S11
"Process"
single-process monitoring and recording program
WIN RT390
RS232
no
no
S12
"ThermLog"
temperature data-acquisition program for TC800
DOS TC800
RS485
no
IA150 (1)
S13
"ProfiSoft"
transmitter configuration and data-acquisition program
WIN TRP (ProfIPAQ)
RS232
yes
no
S14
"HartTemp"
HART Transmitter configuration and data-acquisition program
WIN TRH
HART
no
HART modem (communicator)
discontinued (1) product of NIVELCO
depending on device connected
product of Raycho Raykov product of INOR
Contact COMECO
COMECO reserves the right of changing specifications without prior notice!
(1)
product of INOR
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
miscellaneous Software
Code
Software
Description
OS Devices Interface
Special Cable
Interface Adapter no
Notes
S1
"MiniSoft"
transmitter configuration and data-acquisition program
WIN MiniPAQ
RS232
yes
S2
"RStest"
simple program for RS232 or RS485 communication test
WIN all
RS232 RS485
depending on device connected
S3
"TraCon"
transmitter configuration and data-acquisition program
WIN TRB(I), TRY, RS232 TRZ, TRC
yes
no
free download from www.tracon.bz
S4
"Ipro"
transmitter configuration and data-acquisition program
WIN TRS (IPAQ)
RS232
yes
no
product of INOR
S5
"MePro"
HART Transmitter configuration and data-acquisition program
WIN MESO
HART
no
HART modem (communicator)
product of INOR
RS485
no
IA300
"InfoPrint"
configuration program for IA300 interface adapter / printer / datalogger
WIN IA300
S6 S7
"InfoMonitor"
data-acquisition program for TC800
WIN TC800
RS485
no
IA150
WIN LCSUPx (EchoTrack)
no
"EView"
viewing and configuration software for ultrasonic level transmitters w/ HART interface
HART
S8
HART modem (communicator)
S9
"PolyMonitor" program
universal data-acquisition
WIN all w/ RS485
RS485
no
IA100 IA250
S10
"UniConf"
universal configuration program
WIN all
RS232 RS485
S11
"Process"
single-process monitoring and recording program
WIN RT390
RS232
no
no
S12
"ThermLog"
temperature data-acquisition program for TC800
DOS TC800
RS485
no
IA150 (1)
S13
"ProfiSoft"
transmitter configuration and data-acquisition program
WIN TRP (ProfIPAQ)
RS232
yes
no
S14
"HartTemp"
HART Transmitter configuration and data-acquisition program
WIN TRH
HART
no
HART modem (communicator)
discontinued (1) product of NIVELCO
depending on device connected
product of Raycho Raykov product of INOR
Contact COMECO
COMECO reserves the right of changing specifications without prior notice!
(1)
product of INOR
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
other control instrumentation 8-channel Isolated Current Scanner ICM81 ♦ ♦ ♦ ♦ ♦ ♦ ♦
Triple isolation 8 internally powered input current loops Input current limiter Different retransmission output signals Isolated parallel interface for external control Isolated alarm outputs Self-testing and system-failure alarm
ICM81 is an 8-channel externally-controlled scanner / multiplexer of DC current signals to an isolated linear output, available in 2-wire current and 3-wire current and voltage versions. The scanner provides isolation DC power supply for all input current loops with common ground together with an automatic over-current protection and has a 3-bit isolated parallel port for external channel selection from PLC. ICM81 is equipped with sophisticated alarm circuit providing isolated alarm outputs and LED indication in case of input break and overload, output failure, and internal error. Designed for DIN-rail mounting, with its convenient plastic enclosure and detachable screw terminals, ICM81 can be very useful in industrial applications requiring DC current multiplexing with isolation, extending PLC analog input possibilities.
Technical specifications Analog inputs Number of inputs Input signal Operating range Absolute range Resolution Scanning period Input connection Input-loop power supply (ILPS) ILPS current limitation Isolation between analog inputs Isolation from main power supply
(scanned inputs) 8 DC current 0...20 mA or 4....20 mA 0...22 mA approx. 10-bit 5s 2-wire or 3-wire externally or internally (1) powered 180 mA none (common ground and supply) 1000 V
Addressing input Input configuration Logic '0' Logic '1' Consumption Input function Isolation from analog inputs
3-bit parallel port not connected connected to power supply > 12 VDC < 2 mA at logic '1' remote channel selection 2500 V
Current output - maximum load Voltage output - minimum load Resolution Output delay Output connection Isolation from analog inputs Isolation from main power supply
(3)
Measurement error Temperature drift
0.2% from span 0.01% from span for 1 °C
Power supply Supply voltage Consumption
24 VDC ± 10% max. 250 mA
Indication 'PWR' green LED 'BREAK' red LED 'OVRLD' red LED Blinking LEDs
retransmission of selected input channel 0....20 mA or 4...20 mA 750 Ω at 24V/20mA 0...10 V 1 MΩ approx. 12-bit max. 50 ms 3-wire 1000 V none (common ground)
Operating temperature Operating humidity
for device power ON for selected input channel under range for selected input channel over range for output current loop error or system failure
Case material Mounting Wiring Dimensions Weight Protection, front/terminals
Code values
G6
Analog inputs (2)
DB - 0…20 mA, DC - 4…20 mA, Z - other (3)
G11
Analog output
E - 0…20 mA, F - 4…20 mA, K - 0…10 V, Z - other (3)
All analog inputs are of a same type! Contact COMECO
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
-10...65 °C 0...85 %RH
Design and materials
ICM81 - G6.G11
Code Feature or option
(2)
Accuracy
Provides isolated loop supply voltage - 24V/180mA for all input channels!
Ordering code
MOS gate 0.1A/60V not connected connected to common ground (0 V) input signal under- or over-range 2500 V
Operating conditions
Output function
(1)
Output type Logic '0' Logic '1' (active alarm) Outputs function Isolation from analog inputs
plastic on 35 mm DIN rail plug-in terminals 70x110x58 mm max. 150 g IP54 / IP20
COMECO reserves the right of changing specifications without prior notice!
Analog output
Alarm outputs
other control instrumentation Remote Set-point Unit TC10 ♦ ♦ ♦ ♦
Easy and convenient set-point setting via rotating dial Passive or active input channel 48x48 DIN-sized front panel Panel or rail mounting
TC10 is a self-contained unit for remote set-point setting. Replacing scrolling through controller menus with simple turning of a dial, the unit is used as accessory for programmable controllers when set point has to be changed frequently. Another TC10 application is in cases, in which there is a need to adjust the set point from a remote location – far from controller panel. Two variants are available: passive – providing resistive output signal (5 kΩ potentiometer) – and active – generating current or voltage signal proportional to set-point value. The TC10 unit is a convenient supplement to COMECO's RT controller series and other manufacturers’ automation systems.
Technical specifications Output
Power supply 0...5 kΩ 0...5 kΩ 0...max. 1 MΩ 0(4)...20 mA 0...1 V, 0...2 V, 0...5 V, or 0...10 V 0...max. 40 mA or 0...max. 10 V
Passive, resistive Passive, potentiometer Other passive (1) Active, DC current Active, DC voltage Other active (1)
Accuracy 1% from span 0.01% from span for 1 °C 0.2% per year
Setting accuracy Temperature drift Long-term stability
Indication and controls 270° arc 40 or 50, depending on the range 0…100%, 0…100 °C, 0…200 °C, 0…400 °C, 0…750 °C, 0…1000 °C, or other on request LED for active output
Dial Dial divisions Dial range (2)
LEDs (1) (2) (3)
Mains supply voltage Isolated low voltage Consumption
230 VAC or 115 VAC 12…24 V or 24 VAC max. 2 VA
Operating conditions Ambient temperature Ambient humidity
-10...65 °C 0...85 %RH
Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals
plastic in 45x45 mm panel cut-out or on 35 mm DIN rail socket OCTAL (3) 48x48(front)x95 mm max. 103 mm (w/ socket) max. 250 g IP40 / IP20
Custom; specify range within the limits stated Specify dial range when ordering. Ordered separately (see 'Accessories')
Ordering code
TC10 - G1.G11
Code Feature or option G1
Variant Power supply
Analog output
P - passive, A - active passive
X - none
active
A - 230 VAC, B - 115 VAC, Q - 12…24 V, isolated, R - 24 VAC
passive
N - resistive, P - potentiometer, Z - other (1)
active, current
E - 0...20 mA, F - 4...20 mA, Z - other (1)
active, voltage
G - 0...1 V, H - 0...2 V, I - 0...5 V, K - 0...10 V, Z - other (1)
COMECO reserves the right of changing specifications without prior notice!
G11
Code values
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
other control instrumentation Protection Unit for 3-phase AC Motors TC70 ♦ ♦ ♦ ♦ ♦ ♦
Low cost Monitors LINE (phase) presence and order Monitors phase voltage magnitude Monitors NEUTRAL (zero) presence Overheating-protection input from PTC High reliability
TC70 is a specialized device for monitoring and protection of 3-phase asynchronous motors, designed for DIN-rail mounting. It monitors phase presence and order, phase line voltage, and zero presence, and switches off its relay output in the cases of failure. An additional input for connecting a thermistor with positive temperature coefficient (posistor) is used for monitoring motor temperature. A cheap, yet highly reliable device, TC70 can be used not only for motor protection, but also in all cases, in which 3-phase system power supply should be monitored.
Technical specifications Input
Power supply
LINE control input (3-phase) NEUTRAL control input Temperature input
3 x 380 VAC ± 15% 220 VAC ± 15% PTC (RPTC at 25 °C = 1k, 2k, or other)
Output
230 VAC +10/-15% max. 4 VA
Operating conditions
Relay electromechanical Solid state relay Output function
Temperature control Indication (1)
Supply voltage Consumption
3A/250V w/ NO/NC contact 1A/250VAC switches off in situations (1): (a) missing line (R/S/T) or neutral (N), (b) line voltage exceeds 270 ± 10 V, (c) line voltage drops below 170 ± 10 V, (d) line order is not RST, STR, or TRS switches off when PTC indicates 70 °C LED for relay ON
Operating temperature Operating humidity
-10...65 °C 0...85 %RH
Design and materials Case material Mounting Wiring Dimensions Weight Protection, case/terminals
plastic on 35 mm DIN rail screw terminals 45x78x108 mm max. 300 g IP40 / IP00
Other phase voltages than the described in points (b) and (c) may be monitored if requested.
Ordering code
TC70 - G5.G6
Code Feature or option
Code values
Relay output
C - relay NO/NC, D - SSR
G6
Temperature control input
BP - PTC 1k, BQ - PTC 2k, BZ - other PTC (specify!)
COMECO reserves the right of changing specifications without prior notice!
G5
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
other control instrumentation RPM Controller for 1-phase AC Motors SCRM ♦ ♦ ♦ ♦ ♦
AC motor power from 0.5 to 5 A / 230 VAC 0…100% speed control Automatic triac retriggering Variant with soft start Load-current sensing available
The SCRM rail-mountable RPM controller, manufactured by COMECO, is designed to control the speed of single-phase AC motors up to 5A/230VAC. The unit operates on the principle of 'phase angle control' from 25 to 180 degrees, adjusted by a front-panel thumbwheel and applied to an internal power triac. SCRM can switch up to 500 VA AC motors of fans or other industrial appliances, connected to the device output. A soft-starter variant allows the motor to reach gradually the pre-adjusted speed, while the 'loadcurrent sensing' option allows keeping the motor speed relatively constant and independent on the load. Thanks to its reliability and simplicity, the SCRM controller can be widely used in applications requiring low-cost AC-motor speed control.
Technical specifications Motor output
Power supply
Control output type Maximum motor power ratings Non rep. surge current at t = 20 ms Minimum holding current Maximum leakage current Critical rate of current rise dI/dt Critical off-state voltage rise dV/dt I2t value for fusing at t = 10 ms Fusing
phase-controlled triac 0.5...5 A / 230 VAC 50 A 50 mA 2 mA 50 A/μs 1000 V/μs 78 A2s by external fuses
Device variants
Control feedbacks Mains voltage compensation Load-current sensing (option) (2) (2)
230 VAC or 115 VAC ± 10% max. 2.5 VA
Operating conditions Operating temperature Temperature drift Operating humidity
-10...40 °C max. 0.05% for 1 °C 0...85 %RH
Indication and controls LEDs Front-panel potentiometer (2)
LED for power ON for speed set-point adjustment, 0…100%
Design and materials 25...180° phase angle 0 to max. speed for ≈ 2 s (1)
RPM controller Soft-starter
(1)
Supply voltage Consumption
≈ 1% of set-point angle per 10 V ≈ 10% of set-point angle per 1 A
Case material Mounting Wiring Dimensions Weight Protection class
plastic on 35 mm DIN rail screw terminals, 2.5 mm2 max. 35x86x58 mm max. 80 g IP40
The time depends on motor current. Only for RMP controller variant!
Ordering code
SCRM - G1 - #1
Code Feature or option
Code values 1 - RPM controller, 2 - soft-starter
G1
Power supply
A - 230 VAC, B - 115 VAC
#1
Load-current sensing (2)
X - none, LS - load-current compensation mounted
COMECO reserves the right of changing specifications without prior notice!
Variant
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
accessories Mounting Accessories for Electronic Devices MA Code
View
Description
Mounting
Application
MAC1
metal clamp for DIN-rail mounting
clamp
for all in-head transmitters; for devices in 40x73x26 mm box (TSR, TSOR, IA250, etc.)
MAC2
set of 2 plastic clamps for DIN-rail mounting
clamp
for devices in 80x80x60 mm box (TI200-Y, RT38-Y, TRx-D, TRU, PSF200, etc.)
clamp
MAC3
plastic clamp for DIN-rail mounting with metal holder
for all in-head transmitters; for devices in 40x73x26 mm box (TSR, TSOR, IA250, etc.); for devices in 50x45x32 mm box (RHA, TSP, TSOP, etc.)
for devices in 40x73x26 mm box (TSR, TSOR)
MAC4
plastic clamp for DIN-rail mounting
clamp
set of 4 stainless steel threaded bushes with nuts
female thread M6
for axial mounting of devices in 65x65x40 mm or 80x80x60 mm box (TI200-Y, RT38-Y, TRx-D, TRU, PSF200, RHW, etc.)
stainless steel threaded nipple with nut
male thread M12; female thread M8
for radial mounting of devices in 65x65x40 mm or 80x80x60 mm box (TI200-Y, RT38-Y, TRx-D, TRU, PSF200, RHW, etc.)
8-pin socket base (OCTAL) for DIN-rail mounting
clamp
for devices in 48x48 mm front-sized case ('S')
11-pin socket base (UNDECAL) for DIN-rail mounting
clamp
for devices in 48x48 mm front-sized case ('S') and devices in other 11-pin boxes (TRZ, RT38-R, TI08-R, etc.)
8-pin socket base (OCTAL) for DIN-rail mounting, EN50022
clamp
for devices in 48x48 mm front-sized case ('S')
MAB3
clamp
MAB4
11-pin socket base (UNDECAL) for DIN-rail mounting, EN50022; Lloyd's Register Approval
for devices in 48x48 mm front-sized case ('S') and devices in other 11-pin boxes (TRZ, RT38-R, TI08-R, etc.)
MAA1
MAR1
MAB1
MAB2
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
for all in-head transmitters
accessories Mounting Accessories for Electronic Devices MA Code
View
Description
Mounting
Application
MAC1
metal clamp for DIN-rail mounting
clamp
for all in-head transmitters; for devices in 40x73x26 mm box (TSR, TSOR, IA250, etc.)
MAC2
set of 2 plastic clamps for DIN-rail mounting
clamp
for devices in 80x80x60 mm box (TI200-Y, RT38-Y, TRx-D, TRU, PSF200, etc.)
clamp
MAC3
plastic clamp for DIN-rail mounting with metal holder
for all in-head transmitters; for devices in 40x73x26 mm box (TSR, TSOR, IA250, etc.); for devices in 50x45x32 mm box (RHA, TSP, TSOP, etc.)
for devices in 40x73x26 mm box (TSR, TSOR)
MAC4
plastic clamp for DIN-rail mounting
clamp
set of 4 stainless steel threaded bushes with nuts
female thread M6
for axial mounting of devices in 65x65x40 mm or 80x80x60 mm box (TI200-Y, RT38-Y, TRx-D, TRU, PSF200, RHW, etc.)
stainless steel threaded nipple with nut
male thread M12; female thread M8
for radial mounting of devices in 65x65x40 mm or 80x80x60 mm box (TI200-Y, RT38-Y, TRx-D, TRU, PSF200, RHW, etc.)
8-pin socket base (OCTAL) for DIN-rail mounting
clamp
for devices in 48x48 mm front-sized case ('S')
11-pin socket base (UNDECAL) for DIN-rail mounting
clamp
for devices in 48x48 mm front-sized case ('S') and devices in other 11-pin boxes (TRZ, RT38-R, TI08-R, etc.)
8-pin socket base (OCTAL) for DIN-rail mounting, EN50022
clamp
for devices in 48x48 mm front-sized case ('S')
MAB3
clamp
MAB4
11-pin socket base (UNDECAL) for DIN-rail mounting, EN50022; Lloyd's Register Approval
for devices in 48x48 mm front-sized case ('S') and devices in other 11-pin boxes (TRZ, RT38-R, TI08-R, etc.)
MAA1
MAR1
MAB1
MAB2
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
for all in-head transmitters
accessories Mounting Accessories for Electronic Devices MA Code
View
Description
Mounting
Application
MAC1
metal clamp for DIN-rail mounting
clamp
for all in-head transmitters; for devices in 40x73x26 mm box (TSR, TSOR, IA250, etc.)
MAC2
set of 2 plastic clamps for DIN-rail mounting
clamp
for devices in 80x80x60 mm box (TI200-Y, RT38-Y, TRx-D, TRU, PSF200, etc.)
clamp
MAC3
plastic clamp for DIN-rail mounting with metal holder
for all in-head transmitters; for devices in 40x73x26 mm box (TSR, TSOR, IA250, etc.); for devices in 50x45x32 mm box (RHA, TSP, TSOP, etc.)
for devices in 40x73x26 mm box (TSR, TSOR)
MAC4
plastic clamp for DIN-rail mounting
clamp
set of 4 stainless steel threaded bushes with nuts
female thread M6
for axial mounting of devices in 65x65x40 mm or 80x80x60 mm box (TI200-Y, RT38-Y, TRx-D, TRU, PSF200, RHW, etc.)
stainless steel threaded nipple with nut
male thread M12; female thread M8
for radial mounting of devices in 65x65x40 mm or 80x80x60 mm box (TI200-Y, RT38-Y, TRx-D, TRU, PSF200, RHW, etc.)
8-pin socket base (OCTAL) for DIN-rail mounting
clamp
for devices in 48x48 mm front-sized case ('S')
11-pin socket base (UNDECAL) for DIN-rail mounting
clamp
for devices in 48x48 mm front-sized case ('S') and devices in other 11-pin boxes (TRZ, RT38-R, TI08-R, etc.)
8-pin socket base (OCTAL) for DIN-rail mounting, EN50022
clamp
for devices in 48x48 mm front-sized case ('S')
MAB3
clamp
MAB4
11-pin socket base (UNDECAL) for DIN-rail mounting, EN50022; Lloyd's Register Approval
for devices in 48x48 mm front-sized case ('S') and devices in other 11-pin boxes (TRZ, RT38-R, TI08-R, etc.)
MAA1
MAR1
MAB1
MAB2
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
for all in-head transmitters
accessories Mounting Accessories for Electronic Devices MA Code
View
Description
Mounting
Application
MAC1
metal clamp for DIN-rail mounting
clamp
for all in-head transmitters; for devices in 40x73x26 mm box (TSR, TSOR, IA250, etc.)
MAC2
set of 2 plastic clamps for DIN-rail mounting
clamp
for devices in 80x80x60 mm box (TI200-Y, RT38-Y, TRx-D, TRU, PSF200, etc.)
clamp
MAC3
plastic clamp for DIN-rail mounting with metal holder
for all in-head transmitters; for devices in 40x73x26 mm box (TSR, TSOR, IA250, etc.); for devices in 50x45x32 mm box (RHA, TSP, TSOP, etc.)
for devices in 40x73x26 mm box (TSR, TSOR)
MAC4
plastic clamp for DIN-rail mounting
clamp
set of 4 stainless steel threaded bushes with nuts
female thread M6
for axial mounting of devices in 65x65x40 mm or 80x80x60 mm box (TI200-Y, RT38-Y, TRx-D, TRU, PSF200, RHW, etc.)
stainless steel threaded nipple with nut
male thread M12; female thread M8
for radial mounting of devices in 65x65x40 mm or 80x80x60 mm box (TI200-Y, RT38-Y, TRx-D, TRU, PSF200, RHW, etc.)
8-pin socket base (OCTAL) for DIN-rail mounting
clamp
for devices in 48x48 mm front-sized case ('S')
11-pin socket base (UNDECAL) for DIN-rail mounting
clamp
for devices in 48x48 mm front-sized case ('S') and devices in other 11-pin boxes (TRZ, RT38-R, TI08-R, etc.)
8-pin socket base (OCTAL) for DIN-rail mounting, EN50022
clamp
for devices in 48x48 mm front-sized case ('S')
MAB3
clamp
MAB4
11-pin socket base (UNDECAL) for DIN-rail mounting, EN50022; Lloyd's Register Approval
for devices in 48x48 mm front-sized case ('S') and devices in other 11-pin boxes (TRZ, RT38-R, TI08-R, etc.)
MAA1
MAR1
MAB1
MAB2
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
for all in-head transmitters
accessories Adjustable Mounting Flange FA DIN 43734 FLANGE Material - cast black steel (see Appendix - Sheath materials) Coating - electrostatically coated powder paint
NOMINAL SIZE
DIMENSIONS d1 (tube OD) [mm]
DN16
DN22
DN32
14...16
20...22
30...32
A [mm]
75
90
90
B [mm]
50
65
65
C [mm]
55
70
70
D [mm]
27
33
33
Fixing: 2 stainless steel screws M6x16 Maximum temperature: 300 째C Maximum pressure: atmosphere
Ordering code
FA - G4
Code Feature or option G4
Nominal size
DN16 (1), DN22, DN32 (1)
Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(1)
Code values
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
accessories DIN Mounting Flange FD DIN 1092-1 VARIANT *
D (FDDx)
FACE *
Material - stainless steel (see Appendix - Sheath materials) Nominal pressure - PN25...PN100
A
B
D
F
flat
raised
groove
recess
G
H
O-ring recess O-ring groove
DESIGN WITHOUT NECK (01)
DESIGN WITH WELDING NECK (11) DESIGN WITH THREADED NECK (13)
Maximum temperature: 850 °C * Other standard types and faces are available on request. Please contact COMECO!
Nominal size
DN10
DN15
DN20
DN25
DN32
DN40
DN50
DN65
18 (3/8") 90
22 (1/2") 95
27.5 (3/4") 105
34.5 (1") 115
43.5 (1¼") 140
49.5 (1½") 150
61.5 (2") 165
77.5 (2½") 185
14 / 16 60
14 / 16 65
16 / 18 75
16 / 18 85
18 100
18 110
20 125
22 145
d3 [mm]
30
35
45
52
60
70
84
104
h1 [mm]
22
22
26
28
30
32
34
38
d4 [mm]
40
45
58
68
78
88
102
122
d1 D [mm] b1 / b2 [mm] k [mm]
w [mm] y / z [mm] r [mm] d2 [mm] Bolts
29
36
43
51
61
73
95
40 / 28 4
51 / 35 4
58 / 42 4
66 / 50 6
76 / 60 6
88 / 72 6
110 / 94 6
14
14
14
14
18
18
18
18
4 x M12
4 x M12
4 x M12
4 x M12
4 x M16
4 x M16
4 x M16
8 x M16
FDD - G4.G5.G9.G10.G14
Code Feature or option
(1) (2)
Code values
Design
01 - w/o neck, 11 - w/ welding neck, 13 - w/ treaded neck
G4
Nominal size
DN10, DN15, DN20, DN25, DN32, DN40, DN50, DN65, Z - other (specify!) (1)
G5
Tube diameter (for welding) 'd1' [mm]
X - none (blind flange), 18...77.5 (2), Z - other
G9
Connection thread 'd1'
X - none, U3 - G3/8", U4 - G1/2", U6 - G3/4", U12 - G1", U27 - G1¼", U13 - G1½", U14 - G2", Z - other (specify!) (1)
G10
Material
M1 - 1.4301, M2 - 1.4541 (1), M3 - 1.4571 (1), M9 - 1.4404 or 1.4435, Z - other (specify!) (1)
G14
Face
A - flat, B - raised, D - groove, F - recess, G - O-ring recess, H - O-ring groove
Contact COMECO! Applicable for the selected size
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
24 35 / 23 4
accessories
SHORT-NECK VARIANT FOR TUBE WELDING Material - stainless steel (see Appendix - Sheath materials) Nominal pressure - PN40
**
**
W (FDW)
THREADED DIN 2566 VARIANT Material - stainless steel (see Appendix - Sheath materials) Nominal pressure - PN16...PN40
T (FDT)
** DIN 2633 welding neck flanges and ANSI RF flanges are also available on request. Please contact COMECO!
Nominal size
DN6
DN8
d1 thread d1 tube for welding [mm]
1/8"
1/4" 8, 10, 12
DN10
DN15
3/8" 1/2" 12, 14, 16
DN20
DN25
DN32
DN40
3/4" 1" 16, 20, 25
1¼" 1½" 25, 32, 40
DN50 2"
DN65
2½" 40, 50, 65
D [mm]
75
80
90
95
105
115
140
150
165
185
b [mm] k [mm]
12 50
12 55
14 60
14 65
16 75
16 85
16 100
16 110
18 125
18 145
d3 [mm]
20
25
30
35
45
52
60
70
85
105
h1 [mm]
18
18
20
20
24
24
26
26
28
32
d4 [mm]
32
38
40
45
58
68
78
88
102
122
f [mm] r [mm]
2 2
2 2
2 3
2 3
2 4
2 4
2 5
3 5
3 5
3 6
s [mm] Bolts
1.5
1.5
1.8
2
2.3
2.6
2.6
2.6
2.9
2.9
4 x M10
4 x M10
4 x M12
4 x M12
4 x M12
4 x M12
4 x M16
4 x M16
4 x M16
8 x M16
d2 [mm] Weight [kg]
11
14
14
14
14
18
18
18
18
0.38
0.54
0.61
0.91
1.10
1.60
1.78
2.43
3.18
FD - G4.G5.G9.G10
Code Feature or option G4
Code values
Variant
W - for tube welding, T - threaded DN6, DN8, DN10, DN15, DN20, DN25, DN32, DN40, DN50, DN65, Z - other (specify!) (1)
Nominal size (3)
X - none (blind flange), 8...65 (2), Z - other
G5
Tube diameter (for welding) 'd1' [mm]
G9
Connection thread 'd1' (2,4)
X - none, U3 - G3/8", U4 - G1/2", U6 - G3/4", U12 - G1", U27 - G1¼", U13 - G1½", U14 - G2", Z - other (specify!) (1)
G10
Material
M1 - 1.4301, M2 - 1.4541 (1), M3 - 1.4571 (1), M9 - 1.4404 or 1.4435, Z - other (specify!) (1)
(1)
Contact COMECO! Applicable for the selected size Code only for variant 'W'! (4) Code only for variant 'T'! (2)
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
11 0.33
accessories ANSI Mounting Flange FN ANSI B16.5 BLIND FLANGE
B (FNB)
Material - stainless steel (see Appendix - Sheath materials) Nominal pressure - PN25...PN100
DIMENSIONS * SIZE 1/2"
NO DRILL
3/4"
1"
DRILLED FOR PIPE WELDING
1 ¼"
1 ½"
2"
2 ½"
DRILLED AND THREADED
3"
pipe OD D k G class [mm] [mm] [mm] [mm] 21.3
26.7
33.4
42.2
48.3
60.3
73.0
88.9
150 300 600 150 300 600 150 300 600 150 300 600 150 300 600 150 300 600 150 300 600 150 300 600
88.9
60.5
95.2
66.5
98.6
69.8
117.3
82.5
108
79.2
124
35.1
42.9
50.8 88.9
117.3 133.4
63.5 98.5
127 155.4
114.3
152.4
120.6
165.1
127
177.8
139.7
190.5
149.2
190.5
152.4
209.5
168.1
73.2
91.9
104.8
127
b1 RF d2 holes [mm] [mm] [mm] 9.7 12.7 14.2 11.2 14.2 15.7 12.7 16 17.5 14.2 18 20.6 16 19 22.3 17.5 20.8 25.4 20.9 23.9 28.4 22.4 26.9 31.7
1.5 6.3
15.7
1.5 6.3 1.5 6.3 1.5 6.3 1.5 6.3 1.5
19 15.7 19 15.7 19 15.7
6.3 1.5 6.3
4
22.3 19
6.3 1.5
4
8
19
4
22.3
8
19
4
22.3
8
weight [kg] ≈ 0.42 ≈ 0.64 ≈ 0.76 ≈ 0.61 ≈ 1.11 ≈ 1.28 ≈ 0.86 ≈ 1.39 ≈ 1.60 ≈ 1.17 ≈ 1.79 ≈ 2.23 ≈ 1.53 ≈ 2.66 ≈ 3.25 ≈ 2.42 ≈ 3.18 ≈ 4.15 ≈ 3.94 ≈ 4.85 ≈ 6.13 ≈ 4.93 ≈ 6.81 ≈ 8.44
Maximum temperature: 850 °C Maximum pressure: class 150 - 150 psig class 300 - 300 psig class 600 - 600 psig * Other standard types and dimensions are available on request. Please contact COMECO!
FNB - G4'/4".G5.G9.G10.G14
Code Feature or option
(1)
Code values
G4'
Nominal size
50 - 1/2", 75 - 3/4", 100 - 1", 125 - 1¼", 150 - 1½", 200 - 2", 250 - 2½", 300 - 3", Z - other (specify!) (1)
G4"
Nominal pressure (class)
150 - 10 bar (150 psig), 300 - 20 bar (300 psig), 600 - 40 bar (600 psig)
G5
Pipe diameter (for welding) 'd1' [mm]
X - none (blind flange), OD (see table above)
G9
Connection thread 'd1'
X - none, U4 - G1/2", U10 - NPT 1/2", U6 - G3/4", U11 - NPT 3/4", U12 - G1", U15 - NPT 1", U27 - G1¼", U28 - NPT 1¼", U13 - G1½", U16 - NPT 1½", U14 - G2", U17 - NPT 2", U21 - G3", U22 - NPT 3", Z - other (specify!) (1)
G10
Material
M1 - 1.4301, M2 - 1.4541 (1), M3 - 1.4571 (1), M9 - 1.4404 or 1.4435, Z - друг (поясни!) (1)
G14
Face
A - flat, B - raised
Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
accessories Small Mounting Flange FS SMALL MOUNTING FLANGE Material - aluminum, brass, or stainless steel (see Appendix - Sheath materials) Application - with TS, LC, and RH probes
NOMINAL SIZE *
DIMENSIONS
DN5 DN6 DN8 DN9 DN10 DN12 DN14 DN16 DN18 d1 (probe OD) [mm] D [mm]
5
6
8
9
10
12
14
16
18
32
34
40
40
42
44
46
48
50
b [mm]
2 (stainless steel), 3 (brass), or 4 (aluminum)
k [mm]
24
26
30
30
32
34
36
38
40
d3 [mm]
13
14
18
19
20
22
24
26
28
h1 [mm]
14
14
16
16
16
16
16
18
18
no. of bolts
2
2
3
3
4
4
4
4
4
Fixing: stainless steel screw M4 Maximum temperature: 300 째C Maximum pressure: atmosphere * Other dimensions are available on request. Please contact COMECO!
Ordering code
FS - G4.G10
Code Feature or option Nominal size
DN5, DN6, DN8, DN9, DN10, DN12, DN14, DN16, DN18, Z - other (specify!)
G10
Material
AL - aluminum, BR - brass (Ni-plated) (1), M1 - 1.4301, M2 - 1.4541 (1), M3 - 1.4571 (1), M9 - 1.4404
Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(1)
Code values
G4
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
accessories Mounting Adapter YB BAYONET MOUNTING ADAPTER
YBx
DIMENSIONS *
Material - aluminum, brass, or stainless steel (see Appendix - Sheath materials) Application - with TS bayonet probes
E
SCREW DESIGN (1)
M10x1.5
SW
K1 [mm]
D [mm]
H2 [mm]
Spring OD [mm]
12 (13)
6
14 (15)
7
9
M10x1
10 G1/8"
Bayonet Cap [mm]
-
10...100
1/8" NPT 10 12
M12x1.5 M10x1.5 M10x1
WRENCH DESIGN (2)
G1/8"
14
1/8" NPT
G1/4"
17
12
M16x1.5 19
3/8" NPT
10...100
12 (13)
12
15 (16)
12 / 15
15 (16) / 18 (19)
15
1/4" NPT G3/8"
10
10
M12x1.5 M14x1.5
9
13
12...100 15
6, 7
6, 7, 8 18 (19)
15
Maximum temperature: 850 °C Maximum pressure: atmosphere * Other dimensions are available on request. Please contact COMECO!
YB - G4.G6.G9'.G9".G10
Code Feature or option
(1) (2)
Code values
Design
1 - screw, 2 - wrench
G4
Spring outer diameter 'd' [mm] (1)
6, 7, 8
G6
Bayonet length 'H2' [mm]
10…100 (see table above)
(1)
X - none (2), Q0 - M16x1.5, Q3 - G3/8", Q7 - M12x1.5, Q8 - M14x1.5, Q9 - 3/8" NPT, Q18 - G1/8", Q19 - 1/8" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Q30 - M10x1.5, Z - other (specify!) (2)
G9'
Connection thread 'E'
G9"
Bayonet diameter 'D' [mm] (1)
10, 12, 15, Z - other (specify!) (2)
G10
Material
AL - aluminum, BR - brass (Ni-plated) (2), M1 - 1.4301, M2 - 1.4541 (2), M3 - 1.4571 (2), M9 - 1.4404
Applicable for the selected design Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
accessories Mounting Adapter YD THREADED MOUNTING ADAPTER
YDx
DIMENSIONS *
Material - stainless steel (see Appendix - Sheath materials) Application - with probes series TS, LC, PS, etc.
E M10x1(1.5); G1/8"
STANDARD M/M DESIGN (1)
1/8" NPT; M12x1.5 M14x1.5; G1/4" 1/4" NPT M16x1.5; G3/8" 3/8" NPT M18x1.5 M20x1.5; G1/2" 1/2" NPT M27x2; G3/4" 3/4" NPT M33x2; G1" 1" NPT M10x1(1.5); G1/8"
EXTENDED M/F DESIGN (2)
1/8" NPT; M12X1.5 M14x1.5; G1/4" 1/4" NPT M16x1.5; G3/8" 3/8" NPT M18x1.5 M20x1.5; G1/2" 1/2" NPT M27x2; G3/4" 3/4" NPT M33x2; G1" 1" NPT M16x1.5; G3/8"
LOW-PROFILE M/F DESIGN (3)
3/8" NPT M18x1.5 M20x1.5; G1/2" 1/2" NPT M27x2; G3/4" 3/4" NPT M33x2; G1" 1" NPT
SW 17 19 22 24 27 32 36 17
19 22 24 27 32 36 22 24 27 32 36
K1 [mm]
N
H2 [mm]
dmax [mm]
M8 / M10 / M12 G1/8" / 1/8" NPT
8 / 9 / 10 9 / 10
5/6/6 5/5
as above; M14 / G1/4" / 1/4" NPT
as above; 12 / 12 / 15
as above; 8/6/6
15
as above; M16 / G3/8" / 3/8" NPT
as above; 13 / 13 / 15
as above; 10 / 10 / 10
13
as above; M18x1.5
as above; 13
as above; 10
15
as above; M20 / G1/2" / 1/2" NPT
as above; 15 / 15 / 20
as above; 12
as above; M27 / G3/4" / 3/4" NPT
as above; 17 / 17 / 20
as above; 16
as above; M33 / G1" / 1" NPT
as above; 19 / 19 / 25
as above; 20
M8 / M10 / M12 / M14 G1/8"(NPT) / G1/4"(NPT)
8 / 9 / 10 / 12 8 / 11
6 / 6 / 8 / 10 6/8
as above; M16 / G3/8" / 3/8" NPT
as above; 13 / 13 / 12
as above; 12 / 12 / 12
as above; M18
as above; 14
as above; 14
as above; M20 / G1/2"(NPT)
as above; 15 / 15
as above; 16 / 16
as above; M27 / G3/4" / 3/4" NPT
as above; 17 / 17 / 16
as above; 20 / 20 / 20
as above; M33 / G1" / 1" NPT
as above; 19 / 19 / 18
as above; 20 / 20 / 20
15
M8 / M10 / M12 G1/8"(NPT) / G1/4"(NPT)
8 / 9 / 10 8 / 11
6/6/8 6/8
13
as above; M14
as above; 12
as above; 10
15
as above; M16 / G3/8" / 3/8" NPT
as above; 13 / 13 / 12
as above; 12 / 12 / 12
as above; M18 / M20 / G1/2"(NPT)
as above; 14 / 15 / 15
as above; 14 / 16 / 16
as above; M27 / G3/4" / 3/4" NPT
as above; 17 / 17 / 16
as above; 20 / 20 / 20
9 10 12 15 13
20 17 20 19 25 9 10 12 15 13 15 13 15 20 17 20 19 25 13
20 17 20 19 25
* Other dimensions are available on request. Please contact COMECO! M16x1.5; G3/8"
GLAND-TYPE DESIGN (4)
3/8" NPT M18x1.5 M20x1.5; G1/2" 1/2" NPT M27x2; G3/4" 3/4" NPT M33x2; G1" 1" NPT
22 24 27 32 36
13
3...8
15 13 15 20 17
N and SW1 are specified by the manufacturer
20 19 25
Maximum temperature: dependant on ferrule material Maximum pressure: 6(10) bar DN = d
* Other dimensions are available on request. Please contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
3...8 4...12 4...12 6...16 6...16 8...20
COMECO reserves the right of changing specifications without prior notice!
Maximum temperature: 850 째C Maximum pressure: 40 bar
accessories
Ordering code
YD - G4.G9'G9".G10'G10"
Code Feature or option
Code values
Design
1 - standard m/m, 2 - extended m/f, 3 - low-profile m/f, 4 - gland-type
Probe diameter 'd' [mm] (1)
1.5, 2, 3, 4, 4.5, 5, 6, 8, 10, 12, 14, 16, 20
Connection thread 'E' (1)
X - none (4), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q7 - M12x1.5, Q8 - M14x1.5, Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q18 - G1/8", Q19 - 1/8" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Q25 - M33x2, Q30 - M10x1.5, Z - other (specify!)
G9"
Probe thread 'N' (1,2)
X - none (4), Q0/U0 - M16x1.5, Q1/U1 - M18x1.5, Q2/U2 - M20x1.5, Q3/U3 - G3/8", Q4/U4 - G1/2", Q5/U5 - M27x2, Q6/U6 - G3/4", Q7/U7 - M12x1.5, Q8/U8 - M14x1.5, Q9/U9 - 3/8" NPT, Q10/U10 - 1/2" NPT, Q11/U11 - 3/4" NPT, Q12/U12 - G1", Q15/U15 - 1" NPT, Q18/U18 - G1/8", Q19/U19 - 1/8" NPT, Q20/U20 - M10x1, Q23/U23 - G1/4", Q24/U24 - 1/4" NPT, Q25/U25 - M33x2, Q26/U26 - M8x1, Q29/U29 - M8x1.25, Q30/U30 - M10x1.5, Z - other (specify!)
G10'
Material
G4 G9'
G10"
Compression fitting ferrule
M1 - 1.4301, M2 - 1.4541 (4), M3 - 1.4571 (4), M9 - 1.4404 or 1.4435, Z - other (specify!) (4) (3)
TF - Teflon®, BR - brass, SS - stainless steel
(1)
COMECO reserves the right of changing specifications without prior notice!
Applicable for the selected design (2) Omit for YD4! (3) Only for YD4! (4) Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
accessories Mounting Bracket YT PIPE-MOUNTING BRACKET
YTx
Material - steel or stainless steel (see Appendix - Sheath materials) Application - pipe mounting for field devices
DIMENSIONS * Design
Pipe Size
1
½" to 1½"
2
1½" to 2"
3
½" to 1½"
4
1½" to 2"
A [mm]
B [mm]
125
108
145
126
L [mm] 80 106 80 106
Tighten up: wrench size 10 Applications: - designs '1' and '2' are suitable for instrument housings with 108 mm mounting distance (e.g. EX8 or EX8W) - designs '3' and '4' are suitable for instrument housings with 126 mm mounting distance (e.g. EX10 or EX10W)
* Other dimensions are available on request. Please contact COMECO!
Ordering code
YT - G10
Code Feature or option Design
1, 2, 3, 4
G10
Material
M1 - 1.4301, M2 - 1.4541, M13 - mild (black) steel (Zn-plated (1))
Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(1)
Code values
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
accessories Mounting Adapter YQ WELDED MOUNTING BUSH Material - stainless steel (see Appendix - Sheath materials) Application - with YP thermowells or separately
DIMENSIONS * Thermowell OD
Connection Thread M20x1.5, M27x2
≤ 17 mm
G1/2", G3/4" 1/2" NPT, 3/4" NPT M27x2, M33x2
≤ 30 mm
G3/4", G1" ¾" NPT, 1" NPT
Maximum temperature: 850 °C Maximum pressure: 63 bar
* Other dimensions are available on request. Please contact COMECO!
Ordering code
YQ - G9.G10
Code Feature or option G9
Connection thread
G10
Material
M1 - 1.4301, M2 - 1.4541 (1), M3 - 1.4571 (1), M9 - 1.4404 or 1.4435, Z - other (specify!) (1)
Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(1)
Code values X - none, Q2 - M20x1.5, Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Z - other (specify!)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
accessories Protecting Accessories for Electronic Devices PA
Code
PAX1_ 0 1 2 3 PAX2_ 0 1 2 3 4 PAX3_ 0 1 2 3 4 PAX4_
Description IP65 ABS plastic box 65x65x40 mm, with mounting plate
Mounting
Application
free, wall, or rail (with clamp MAC4)
for protection of devices with maximum overall dimensions 40x40x25 mm or ø45x25 mm (e.g. low-profile in-head transmitters)
free, wall, or rail (with clamp MAC2)
for protection of devices with maximum overall dimensions 45x45x40 mm or ø50x40 mm (e.g.: in-head transmitters; devices in case type 'M')
free, wall, or rail (with clamp MAC2)
for high protection of devices with maximum overall dimensions 45x45x40 mm or ø50x40 mm (e.g.: in-head transmitters; devices in case type 'M')
free, wall, or rail (with clamp MAC2)
for Ex protection of devices with maximum overall dimensions 45x45x40 mm or ø50x40 mm
- without cable glands - with 1 plastic gland PG7 - with 2 glands PG7 at 90 ° - with 2 glands PG7 at 180 ° IP65 ABS plastic box 80x80x60 mm, with mounting plate - without cable glands - with 1 plastic gland PG7 - with 2 glands PG7 - with 2 glands PG7 at 90 ° - with 2 glands PG7 at 180 ° IP67 Aluminum box 82x77x57 mm, with mounting plate - without cable glands - with 1 metal gland PG7 - with 2 glands PG7 - with 2 glands PG7 at 90 ° - with 2 glands PG7 at 180 ° IP67 Aluminum Ex box 82x77x57 mm, with mounting plate - without cable glands - with 1 Ex gland PG7
(e.g.: in-head transmitters) Approval: Ex e II, EN 50014; IK
- with 2 glands PG7 - with 2 glands PG7 at 90 ° - with 2 glands PG7 at 180 °
COMECO reserves the right of changing specifications without prior notice!
0 1 2 3 4
View
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
accessories Explosion-proof Instrument Housing EX Variant
8
10
Specifications pressure die-cast aluminum (max. 0.5% Mg), painted with chemically resistant paint, or stainless steel grade AISI 316 (1)
Material Overall dimensions
125x105.5x94.5(height) mm
145x125.5x107(height) mm
ø90 mm / M80
ø110 mm / M100 with locking screw
Lid Conduits Cable glands
3x 1/2" NPT up to 3x ATEX brass glands for non-armored cables 6...8 mm OD (2) (option)
Sensor mounting
via central conduit
Wall mounting
2 holes ø7x108 mm
Pipe mounting
2 holes ø7x126 mm with pipe-mounting bracket (see 'Accessories')
Protection
Ex 'd' IIC; aluminum: IP68, stainless steel: IP66
Approvals Ambient temperature
ATEX 94/9/EC Ex 'd' II GD (for Zone 1/ 2/ 21/ 22) -40...100 °C
Space for transmitter
max. ø60x60 mm
Variant
8W
max. ø85x75 mm
10W
8WD
10WD
Specifications pressure die-cast aluminum (max. 0.5% Mg), painted with chemically resistant paint, or stainless steel grade AISI 316 (1)
Material
125x105.5x109.5(height) mm ø90 mm / M80
145x125.5x127(height) mm ø110 mm / M100 with locking screw
Conduits
105x106.5x162(height) mm 2 x ø90 mm / M80
115x126.5x206(height) mm 2 x ø110 mm / M100 with locking screw
3x 1/2" NPT up to 3x ATEX brass glands for non-armored cables 6...8 mm OD (2) (option)
Cable glands Sensor mounting
via central conduit
Wall mounting
2 holes ø7x108 mm
Pipe mounting Protection
2 holes ø7x126 mm
none
with pipe-mounting bracket (see 'Accessories') Ex 'd' IIC; aluminum: IP68, stainless steel: IP66
Approvals
none
ATEX 94/9/EC Ex 'd' II GD (for Zone 1/ 2/ 21/ 22)
Ambient temperature
-40...85 °C
Space for transmitter
max. ø60x65 mm
Space for indicator
max. ø85x85 mm
max. ø60x28 mm
max. ø85x45 mm
max. ø65x50 mm
max. ø85x75 mm
(1)
Not available for dual-compartment variants! (2) Other cable glands for armored or non-armored cables are available on request.
Ordering code
EX - G10 - #1
Code Feature or option
Code values
Variant
8, 10 - closed, 8W, 10W - windowed, 8WD, 10WD - windowed, dual-compartment
G10
Material
AL - painted aluminum, SS - stainless steel 316 (1)
#1
ATEX cable glands
X - none, CG - 1 cable gland mounted, 2CG - 2 cable glands mounted, 3CG - 3 cable glands mounted
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Overall dimensions Lid
accessories Threaded Bored Thermowell YPTB
YPTB
Material - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes STANDARD TIP
DIMENSIONS * E M20x1.5; G1/2”
SW K1
27
14
N
H2 [mm]
H1 [mm]
d1 [mm]
M14x1.5; G3/8”
15
20...100
4 / 5.5
20
25...100
7
15
20...100
4 / 5.5
14
20
25...100
7/9
17
M27x2; G3/4"
25
30...100
M14x1.5; G3/8”
15
20...100
4 / 5.5
14
20
25...100
7/9
17 / 19
M27x2; G3/4"
25
30...100
M33x2; G1"
30
35...100
M18x1.5 M20x1.5; G1/2" M14x1.5; G3/8”
M27x2; G3/4"
M33x2; G1"
32
16
36
18
1/2” NPT
27
25
3/4" NPT
32
25
1" NPT
NARROWED TIP
M20x1.5; G1/2”
M27x2; G3/4"
M33x2; G1"
Manufactured from solid HEX or round bar
36
27
32
36
25
14
16
18
1/2” NPT
27
25
3/4" NPT
32
25
L = U + K1 + H1
1" NPT
M20x1.5; G1/2"
M18x1.5
Manufactured from solid HEX or round bar L = U + K1 + H1
M18x1.5
36
25
M20x1.5; G1/2"
F1 [mm] 14
7 / 9 / 11 17 / 19 / 21
3/8” NPT
15
20...100
4 / 5.5
1/2" NPT
20
25...100
7 4 / 5.5
13
7/9
16
3/8” NPT
15
20...100
1/2" NPT
20
25...100
3/4" NPT
25
30...100
3/8” NPT
15
20...100
4 / 5.5
13
20
25...100
7/9
16
3/4" NPT
25
30...100
1" NPT
30
35...100
M14x1.5; G3/8”
15
20...100
M18x1.5
20
25...100
20
25...100
M14x1.5; G3/8”
15
20...100
M18x1.5
20
25...100
M20x1.5; G1/2"
20
25...100
M27x2; G3/4"
25
30...100
M14x1.5; G3/8”
15
20...100
M18x1.5
20
25...100
M20x1.5; G1/2"
20
25...100
M27x2; G3/4"
25
30...100
M33x2; G1"
30
35...100
7 / 9 / 11 16 / 18 / 20 4 / 5.5 7
7/9
7/9
20...100
4 / 5.5
20
25...100
7 4 / 5.5
15
20...100
20
25...100
3/4" NPT
25
30...100
≈ 24
7/9
≈ 30
17 / 19 17 / 19 / 21
≈ 17
13 13
≈ 23
16
3/8” NPT
15
20...100
4 / 5.5
13
1/2" NPT
20
25...100
7/9
16
3/4" NPT
25
30...100
1" NPT
30
35...100
≈ 27
7 / 9 / 11
Probe diameter: d ≤ d1 - 1 Probe thread: G = N Probe length (incl. thread): fixed: n = 0.98 * L - e (DIN) or 0.98 * L - e + 0.5 * H2 (NPT) spring-loaded: n ≈ L - e (DIN) or L - e + 0.5 * H2 (NPT) Maximum temperature: 850 °C Maximum pressure: 100 bar
16 / 18 / 20
INSERTION LENGTH d1 [mm]
U [mm]
<7
max. 300
7...9
max. 500
11
max. 700
* Other dimensions are available on request. Please contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
17 14
7 / 9 / 11
15
14 14
4 / 5.5
3/8” NPT 3/8” NPT
≈ 18
4 / 5.5
1/2" NPT 1/2" NPT
= F1
13
1/2" NPT
M20x1.5; G1/2"
F3 [mm]
COMECO reserves the right of changing specifications without prior notice!
THREADED BORED THERMOWELL
accessories
Ordering code
YPTB - G4.G6.G7.G9'G9".G10.G14
Code Feature or option
Code values
G4
Probe diameter 'd' [mm]
3, 4.5, 5, 6, 8, 10
G6
Length 'U' [mm]
50…700 (see table overleaf) (1)
G7
Length 'H1' [mm] (1)
20…100 (see table overleaf) (1)
G9'
Connection thread 'E' (1)
X - none (2), Q2 - M20x1.5, Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Z - other (specify!)
G9"
Probe thread 'N' (1)
X - none (2), U1 - M18x1.5, U2 - M20x1.5, U3 - G3/8", U4 - G1/2", U5 - M27x2, U6 - G3/4", U8 - M14x1.5, U9 - 3/8" NPT, U10 - 1/2" NPT, U11 - 3/4" NPT, U12 - G1", U15 - 1" NPT, U25 - M33x2, Z - other (specify!)
G10
Material
M1 - 1.4301, M2 - 1.4541 (2), M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)
G14
Tip shape
X - standard closed, N - narrowed
(1)
COMECO reserves the right of changing specifications without prior notice!
Applicable for the selected probe diameter 'd' (2) Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
accessories Threaded DIN Thermowell YPTD
DIN 43772-2 THERMOWELL
YPTDx
Material - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes
DIMENSIONS * FORM
BORED DESIGNS (B6, B7, B9)
E
SW
G1/2"
27
D1 K1 [mm] [mm] 26
14
N
H1 H2(K2) [mm] [mm]
M20x1.5; G1/2"
d1 F1(F2) [mm] [mm] 7
19
15
9 / 11
17
7/9 6
G3/4"
G1"
32
41
32
39
1/2" NPT
16
18
M27x2; G3/4" M20x1.5; G1/2"
22 19
17 15
3/4" NPT
-
1" NPT
36
G1/2"
27
≈ 21
14
M20x1.5; G1/2"
15
12 -
G3/4"
WELDED DESIGNS (W5, W8)
19
M20x1.5; G1/2"
9 Maximum pressure: 100 bar
32
32
16
G1/2"
27
26
14
G3/4"
32
32
16
17
9 / 11
20 / 22 17
9 / 11
≈ 25 26
19 / 20
7 7
≈ 20 27
7
7/9 11 / 13
M27x2; G3/4" M20x1.5; G1/2"
14
19
15
5
7/9 7
17
9 / 11
20 / 22
7
G1/2"
27
26
14
M20x1.5; G1/2"
G3/4"
32
32
16
M27x2; G3/4"
8
22
17 12
14
17
9 / 11 7/9 11 / 13
19 / 20
7
12
9 / 11
14
7/9 M27x2; G3/4"
19
11
7/9 11 / 13
12 / 14 14 / 16
7
12
9 / 11
14
7/9
12 / 14
11 / 13
14 / 16
Probe diameter: d ≤ d1 - 1 Probe thread: G = N Probe length: n = U1+18 (fixed) or n = U1+23 (spring-loaded); + 10 mm (FORM7) Maximum pressure: 25 bar (s=1.5) or 40 bar (s=2.5)
Maximum temperature: 850 °C * Other dimensions are available on request. Please contact COMECO!
YPTD - G4.G6.G9'G9".G10
Code Feature or option
Design
Code values B6 - bored, FORM 6, B7 - bored, FORM 7, B9 - bored, FORM 9, W5 - welded, FORM 5, W8 - welded, FORM 8
G4
Probe diameter 'd' [mm]
6, 8, 10, 12
G6
Length 'U1' [mm]
50…500 (see table above) (1)
G9'
Connection thread 'E' (2)
X - none (3), Q4 - G1/2", Q6 - G3/4", Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Z - other (specify!)
G9"
Probe thread 'N' (2)
X - none (3), Q2 - M20x1.5, U2 - M20x1.5, Q4 - G1/2", U4 - G1/2", Q5 - M27x2, U5 - M27x2, Q6 - G3/4", U6 - G3/4", Z - other (specify!)
G10
Material
M1 - 1.4301, M2 - 1.4541 (3), M3 - 1.4571 (3), M9 - 1.4404 or 1.4435, Z - other (specify!) (3)
(1)
Other lengths are available upon request. Contact COMECO! Applicable for the selected probe diameter (3) Contact COMECO! (2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
accessories Threaded Gland-type Thermowell YPTG GLAND-TYPE THERMOWELL
YPTGx
Sheath - stainless steel (see Appendix - Sheath materials) Ferrule - stainless steel, brass, or Teflon®
DIMENSIONS * E
D1 K1 SW [mm] [mm]
M20x1.5; G1/2"
BORED DESIGN (B)
d1 [mm]
F1 [mm]
N
SW1
26
15
-
≈ 20
31
16
4/5/6/7/9
17
G1/4"
13
-
≈ 21
11 / 13
19
G3/8"
17
35
17
-
≈ 25
21
13
-
15
6, 7, 8, 9
8, 10, 12
G1/4"
13
23
13
6, 7, 8, 9, 10 11
8, 10, 12 14
G1/4" G3/8"
13 17
6, 7, 8, 9, 10 11, 12, 13
8, 10, 12 14, 16
G1/4" G3/8"
13 17
6, 7, 8, 9, 10 11, 12, 13, 16
8, 10, 12, 14, 16, 20
G1/4" G3/8"
13 17
27 1/2" NPT M27x2; G3/4" 32 3/4" NPT M33x2; G1" Maximum pressure: 100 bar
36 1" NPT
Manufactured from solid HEX or round bar
M16x1.5; G3/8"
WELDED DESIGN (W)
3/8" NPT M18x1.5 M20x1.5; G1/2" 1/2" NPT M27x2; G3/4" 3/4" NPT M33x2; G1" 1" NPT
Maximum pressure: 25 bar
22 24 27 32 36
26
15
-
≈ 20
31
16
-
≈ 21
35
17
-
≈ 25
Probe diameter: d = DN ≤ d1 - 1 Free probe length: n ≥ U1+30 Maximum temperature: dependant on ferrule material * Other dimensions are available on request. Please contact COMECO!
YPTG - G4.G6.G9'G9".G10
Code Feature or option
(1) (2)
Code values
Design
B - bored, W - welded
G4
Probe diameter 'd' [mm]
3, 4, 4.5, 5, 6, 8, 10, 12
G6
Length 'U1' [mm]
30…500 (see table above)
G9'
Connection thread 'E' (1)
X - none (2), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Z - other (specify!)
G9"
Compression fitting ferrule
TF - Teflon® (up to 200 °C), BR - brass (up to 400 °C), SS - stainless steel (up to 800 °C)
G10
Sheath material
M1 - 1.4301, M2 - 1.4541 (2), M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)
Applicable for the selected probe diameter Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
accessories Threaded Thermowell with Fixing Screw YPTS THERMOWELL WITH FIXING SCREW
YPTSx
Sheath - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes
DIMENSIONS * FORM
BORED DESIGN (B)
E
N D1 K1 SW [mm] [mm] [mm]
M20x1.5; G1/2" 1
**
27
26
15
-
≈ 20
d1 [mm]
7 / 9 / 11 M20x1.5; G1/2" 2 ***
22
M16x1.5; G3/8"
WELDED DESIGN (W)
d1
≈ 20
22
3/8" NPT 1 **
M18x1.5
24
M20x1.5; G1/2"
27
14.5 ****
1/2" NPT M16x1.5; G3/8"
21
13
-
15
23
13
26
15
-
≈ 20 13
19
3/8" NPT 2 *** Maximum probe length: n = U1+4 Maximum pressure: 25 bar
6 / 8 / 9(10)
5/6/8
8 / 10 / 12
6/8 9(10) / 11
5/6 8 / 10
8 / 10 12 / 14
6 / 8 / 9(10)
5/6/8
8 / 10 / 12
6/8 9(10) / 11
5/6 8 / 10
8 / 10 12 / 14
15 d1
M18x1.5 M20x1.5; G1/2"
6 / 8 / 10 13 / 15 / 17
15
1/2" NPT
Manufactured from solid HEX or round bar
F1 [mm]
14.5 ****
1/2" NPT
Maximum probe length: n = U1-2 Maximum pressure: 100 bar
d [mm]
22
1/2" NPT
1
13 15 ≈ 20
Free probe length: n ≥ U1+13 Fixing screw: M4, stainless steel Maximum temperature: 450 °C * Other dimensions are available on request. Please contact COMECO! ** for temperature gauges *** for TS probes **** gauge neck + 0.5 mm
YPTS - G4.G6.G9.G10
Code Feature or option
(1) (2)
Design
Code values B1 - bored, FORM1, B2 - bored, FORM2, W1 - welded, FORM1, W2 - welded, FORM2
G4
Probe diameter 'd' [mm]
5, 6, 8, 10
G6
Length 'U1' [mm]
30…300 (see table above)
G9
Connection thread 'E' (1)
X - none (2), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Z - other (specify!)
G10
Material
M1 - 1.4301, M2 - 1.4541 (2), M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)
Applicable for the selected probe diameter Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
accessories Threaded Tapered Thermowell YPTT THREADED TAPERED THERMOWELL
YPTT
Material - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes
DIMENSIONS * E M20x1.5; G1/2”
SW K1 27
14
N
H2 [mm]
H1 [mm]
d1 [mm]
M14x1.5; G3/8”
15
20...100
4 / 5.5
20
25...100
7
15
20...100
4 / 5.5
14
20
25...100
7/9
17
M18x1.5 M20x1.5; G1/2" M14x1.5; G3/8”
M27x2; G3/4"
M33x2; G1"
Manufactured from solid HEX or round bar
32
16
M20x1.5; G1/2"
36
18
27
25
3/4" NPT
32
25
36
25
L = U + K1 + H1
F1 [mm]
14
≈ 18
≈ 24
M27x2; G3/4"
25
30...100
M14x1.5; G3/8”
15
20...100
4 / 5.5
14
20
25...100
7/9
17 / 19
M27x2; G3/4"
25
30...100
M33x2; G1"
30
35...100
M18x1.5
1/2” NPT
1" NPT
M18x1.5
F3 [mm]
M20x1.5; G1/2"
7 / 9 / 11 17 / 19 / 21
3/8” NPT
15
20...100
4 / 5.5
1/2" NPT
20
25...100
7 4 / 5.5
13
7/9
16
3/8” NPT
15
20...100
1/2" NPT
20
25...100
3/4" NPT
25
30...100
13
3/8” NPT
15
20...100
4 / 5.5
13
1/2" NPT
20
25...100
7/9
16
3/4" NPT
25
30...100
1" NPT
30
35...100
Probe diameter: d ≤ d1 - 1 Probe thread: G = N Probe length (incl. thread): fixed: n = 0.98 * L - e (DIN) or 0.98 * L - e + 0.5 * H2 (NPT) spring-loaded: n ≈ L - e (DIN) or L - e + 0.5 * H2 (NPT) Maximum temperature: 850 °C Maximum pressure: 160 bar
≈ 30
≈ 17
≈ 23
≈ 27
7 / 9 / 11 16 / 18 / 20
INSERTION LENGTH d1 [mm]
U [mm]
<7
max. 300
7...9
max. 500
11
max. 700
* Other dimensions are available on request. Please contact COMECO!
YPTT - G4.G6.G7.G9'G9".G10
Code Feature or option
(1) (2)
Code values
G4
Probe diameter 'd' [mm]
3, 4.5, 5, 6, 8, 10
G6
Length 'U' [mm]
50…700 (see table above) (1) (1)
20…100 (see table above) (1)
G7
Length 'H1' [mm]
G9'
Connection thread 'E' (1)
X - none (2), Q2 - M20x1.5, Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Z - other (specify!)
G9"
Probe thread 'N' (1)
X - none (2), U1 - M18x1.5, U2 - M20x1.5, U3 - G3/8", U4 - G1/2", U5 - M27x2, U6 - G3/4", U8 - M14x1.5, U9 - 3/8" NPT, U10 - 1/2" NPT, U11 - 3/4" NPT, U12 - G1", U15 - 1" NPT, U25 - M33x2, Z - other (specify!)
G10
Material
M1 - 1.4301, M2 - 1.4541 (2), M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)
Applicable for the selected probe diameter 'd' Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
accessories Threaded Welded Thermowell YPTW YPTW
Material - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes STANDARD TIP
DIMENSIONS * E M20x1.5; G1/2”
M27x2; G3/4"
M33x2; G1"
SW K1
27
32
36
14
16
18
1/2” NPT
27
25
3/4" NPT
32
25
Manufactured from solid HEX or round bar U = 50...1500 mm L = U + K1 + H1 S = 1...3 mm 1" NPT
NARROWED TIP
M20x1.5; G1/2”
M27x2; G3/4"
M33x2; G1"
S1
36
27
32
36
25
14
16
18
1/2” NPT
27
25
3/4" NPT
32
25
Manufactured from solid HEX or round bar U = 50...1500 mm L = U + K1 + H1 S = 1...3 mm S1 = 1...2 mm
1" NPT
36
25
N
H2 [mm]
H1 [mm]
M14x1.5; G3/8”
15
20...100
M18x1.5
20
25...100
M20x1.5; G1/2"
20
25...100
M14x1.5; G3/8”
15
20...100
M18x1.5
20
25...100
M20x1.5; G1/2"
20
25...100
M27x2; G3/4"
25
30...100
M14x1.5; G3/8”
15
20...100
M18x1.5
20
25...100
M20x1.5; G1/2"
20
25...100
M27x2; G3/4"
25
30...100
M33x2; G1"
30
35...100
3/8” NPT
15
20...100
1/2" NPT
20
25...100
3/8” NPT
15
20...100
1/2" NPT
20
25...100
3/4" NPT
25
30...100
3/8” NPT
15
20...100
1/2" NPT
20
25...100
3/4" NPT
25
30...100
1" NPT
30
35...100
M14x1.5; G3/8”
15
20...100
M18x1.5
20
25...100
M20x1.5; G1/2"
20
25...100
M14x1.5; G3/8”
15
20...100
M18x1.5
20
25...100
M20x1.5; G1/2"
20
25...100 30...100
M27x2; G3/4"
25
M14x1.5; G3/8”
15
20...100
M18x1.5
20
25...100
M20x1.5; G1/2"
20
25...100
M27x2; G3/4"
25
30...100
M33x2; G1"
30
35...100
3/8” NPT
15
20...100
1/2" NPT
20
25...100
3/8” NPT
15
20...100
1/2" NPT
20
25...100
3/4" NPT
25
30...100
3/8” NPT
15
20...100
1/2" NPT
20
25...100
3/4" NPT
25
30...100
1" NPT
30
35...100
Probe diameter: d ≤ (F3 - 2*S) - 1 Probe thread: G = N Probe length (incl. thread): fixed: n = 0.98 * L - e (DIN) or 0.98*L - e + 0.5*H2 (NPT) spring-loaded: n ≈ L - e (DIN) or L - e + 0.5*H2 (NPT) Maximum temperature: 850 °C
F1 [mm] 10, 12, 14, 1/8", 1/4"
10, 12, 14, 16, 18, 1/8", 1/4", 3/8"
10, 12, 14, 16, 18, 20, 1/8", 1/4", 3/8", 1/2"
= F1
10, 12, 14, 1/8", 1/4" 10, 12, 14, 16, 18, 1/8", 1/4", 3/8" 10, 12, 14, 16, 18, 20, 1/8", 1/4", 3/8", 1/2" 10, 12, 14, 1/8", 1/4"
8, 10
10, 12, 14, 16, 18, 1/8", 1/4", 3/8"
8, 10, 12
10, 12, 14, 16, 18, 20, 1/8", 1/4", 3/8", 1/2"
8, 10, 12, 14
10, 12, 14, 1/8", 1/4"
8, 10
10, 12, 14, 16, 18, 1/8", 1/4", 3/8"
8, 10, 12
10, 12, 14, 16, 18, 20, 1/8", 1/4", 3/8", 1/2"
8, 10, 12, 14
MAXIMUM PRESSURE S(S1) [mm]
P [bar]
1
16
1.5 (2)
25
2.5 (3)
40
* Other dimensions are available on request. Please contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
F3 [mm]
COMECO reserves the right of changing specifications without prior notice!
THREADED WELDED THERMOWELL
accessories
Ordering code
YPTW - G4.G6.G7.G9'G9".G10.G14
Code Feature or option
Code values 10, 12, 14, 16, 18, 20, 1/8" (2), 1/4" (2), 3/8" (2), 1/2" (2)
G4
Tube diameter 'F1' [mm]
G6
Length 'U' [mm]
50…1500 (see table overleaf)
G7
Length 'H1' [mm] (1)
20…100 (see table overleaf) (1)
G9'
Connection thread 'E' (1)
X - none (2), Q2 - M20x1.5, Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Z - other (specify!)
G9"
Probe thread 'N' (1)
X - none (2), U1 - M18x1.5, U2 - M20x1.5, U3 - G3/8", U4 - G1/2", U5 - M27x2, U6 - G3/4", U8 - M14x1.5, U9 - 3/8" NPT, U10 - 1/2" NPT, U11 - 3/4" NPT, U12 - G1", U15 - 1" NPT, U25 - M33x2, Z - other (specify!)
G10
Material
M1 - 1.4301, M2 - 1.4541 (2), M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)
G14
Tip shape
X - standard closed, N - narrowed
(1)
COMECO reserves the right of changing specifications without prior notice!
Applicable for the selected tube diameter 'F1' (2) Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
accessories Weldable DIN Thermowell YPWD DIN 43772-2 THERMOWELL
YPWD
DIMENSIONS * N
F2 [mm]
M14x1.5
18
9
4 / 5.5
M18x1.5
24
12.5
7
Sheath - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes
F3 [mm]
d1 [mm]
H1 H2 [mm] [mm] 16
L [mm]
U [mm]
13
M20x1.5 G1/2"
26
12.5 / 15
7/9
19
15
M27x2 G3/4"
32
15 / 17 / 19
9 / 11 / 13
22
17
110 / 140
65
170 / 200
125
260 / 410
125 / 275
Probe diameter: d = d1 - 1 Probe thread: G = N Probe length: n = 0.98 * L - 5 (fixed) or n ≈ L - 5 (spring-loaded) Maximum temperature: 850 °C Maximum pressure: 160(250*) bar * Other dimensions are available on request. Please contact COMECO!
DIN 43763 THERMOWELL
YPWDx
Sheath - stainless steel (see Appendix - Sheath materials) Application - with TS probes with M18x1.5 external thread
DIMENSIONS * FORM
L [mm]
U [mm]
1
140
65
2 3
200
125 65
4 5
260
6
255
125
F2 [mm]
F3 [mm]
d1 [mm]
b [mm]
24
12.5
7
3.5
30
16
9
4
24
12.5
7
3.5
30
16
9
4
Probe diameter: d = d1 - 1 Probe thread: G = M18x1.5 Probe length: n = 0.98 * L - b (fixed) or n ≈ L - b (spring-loaded) Maximum temperature: 850 °C Maximum pressure: 250(500*) bar * Other dimensions are available on request. Please contact COMECO!
YPW - G4.G6.G9.G10
Code Feature or option Variant
G4
Probe diameter 'd' [mm]
3, 4.5, 6, 8, 10, 12
G6
Length 'L' [mm]
110…410 (see table above) (1)
G9
Probe thread 'N' (2)
X - none (3), U1 - M18x1.5, U2 - M20x1.5, U4 - G1/2", U5 - M27x2, U6 - G3/4", U8 - M14x1.5, Z - other (specify!)
G10
Material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571 (3), M9 - 1.4404 or 1.4435, Z - other (specify!) (3)
(1) (2) (3)
Code values D - DIN 43772-2, D1 - DIN 43763, FORM1, D2 - DIN 43763, FORM2, D3 - DIN 43763, FORM3, D4 - DIN 43763, FORM4, D5 - DIN 43763, FORM5, D6 - DIN 43763, FORM6
Other lengths are available upon request. Contact COMECO! Applicable for the selected probe diameter Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
accessories Weldable Gland-type Thermowell YPWG GLAND-TYPE THERMOWELL
DIMENSIONS *
Sheath - stainless steel (see Appendix - Sheath materials) Ferrule - stainless steel, brass, or Teflon®
U1 [mm]
L [mm]
15
45
30
60
50
80
80
110
100
130
d1 [mm]
DN(d) [mm]
F1 [mm]
N
D1 [mm]
4/5/6/7/9
3/4/5/6/8
8 / 9 / 10 / 11 / 13
G1/4"
20
Probe diameter: d ≤ d1 - 1 Free probe length: n ≥ U1+45 Maximum temperature: dependant on ferrule material Maximum pressure: up to 100 bar (depending on welding technology) * Other dimensions are available on request. Please contact COMECO!
Ordering code
YPWG - G4.G6.G9.G10
Code Feature or option
(2)
Probe diameter 'd' [mm]
3, 4, 4.5, 5, 6, 8, 10
G6
Length 'U1' [mm]
15…100 (see table above) (1)
G9
Compression fitting ferrule
TF - Teflon® (up to 200 °C), BR - brass (up to 400 °C), SS - stainless steel (up to 800 °C)
G10
Sheath material
M1 - 1.4301, M2 - 1.4541 (2), M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)
Other lengths are available upon request. Contact COMECO! Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(1)
Code values
G4
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
accessories Weldable Thermowell with Fixing Screw YPWS THERMOWELL WITH FIXING SCREW
DIMENSIONS *
Sheath - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes
U1 [mm]
L [mm]
15
45
30
60
50
80
80
110
100
130
FORM
N [mm]
D1 [mm]
d1 [mm]
d [mm]
F1 [mm]
1 **
14.5 ****
20
7 / 9 / 11
6 / 8 / 10
11 / 13 / 15
2 ***
d1
18
6/7/9
5/6/8
10 / 11 / 13
Probe diameter: d ≤ d1 - 1 Maximum probe length: n = U1+5 Free probe length: n ≥ U1+45 Fixing screw: M4, stainless steel Maximum temperature: 450 °C Maximum pressure: up to 100 bar (depending on welding technology) * Other dimensions are available on request. Please contact COMECO! ** for temperature gauges *** for TS probes **** gauge neck + 0.5 mm
Ordering code
YPWS - G4.G6.G10
Code Feature or option
(2)
1 - FORM1, 2 - FORM2
G4
Probe diameter 'd' [mm]
3, 4, 4.5, 5, 6, 8, 10
G6
Length 'U1' [mm]
15…100 (see table above) (1)
G10
Material
M1 - 1.4301, M2 - 1.4541 (2), M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)
Other lengths are available upon request. Contact COMECO! Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(1)
Code values
Form
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
accessories Flanged Bored Thermowell YPFB DIN-FLANGED BORED THERMOWELL
YPFBD
DIMENSIONS * N
H2 [mm]
M14x1.5, G3/8”
15
20
22
4 / 5.5
13 / 15
≈ 18
M18x1.5
20
25
28
7
17
≈ 24
M20x1.5, G1/2"
20
25
30
7/9
17 / 19
≈ 26
M27x2, G3/4"
25
30
35
7 / 9 / 11
17 / 19 / 21
≈ 31
Material - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes
H1 [mm]
F2 [mm]
d1 [mm]
F3 [mm]
F1 [mm]
INSERTION LENGTH
Probe diameter: d = d1 - 1 Probe thread: G = N Probe length (incl. thread): n = 0.98 * L - e (fixed) or n ≈ L - e (spring-loaded) Maximum temperature: 850 °C Maximum pressure: 40 bar
d1 [mm]
U [mm]
<7
max. 300
7...9
max. 500
11
max. 700
FLANGE DIMENSIONS * NOMINAL SIZE
D [mm]
DN10 DN15 DN20 DN25 DN32 DN40 DN50
L = U + b + H1 (flat face) or L = U + b + H1 + 2 (raised face)
90 95 105 115 140 150 165
k [mm] 60 65 75 85 100 110 125
b d2 [mm] [mm]
bolts
14 14
4 x M12
16 18
Flange type: DIN 2527 or EN DIN 1092-1 Maximum pressure: PN40
18
4 x M16
20
* Other dimensions are available on request. Please contact COMECO!
Ordering code
YPFBD - G4.G6.G8.G9.G10.G14
Code Feature or option
Code values
G4
Probe diameter 'd' [mm]
3, 4.5, 5, 6, 8, 10
G6
Length 'U' [mm]
50…700 (see table above) (1)
G8
Flange nominal size
DN10 (2), DN15, DN20, DN25, DN32, DN40, DN50, Z - other (specify!) (2)
G9
Probe thread 'N' (1)
Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q8 - M14x1.5, Z - other (specify!) (2)
G10
Material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)
G14
Flange face
A - flat (FF), B - raised (RF), D - groove, F - recess, G - O-ring recess, H - O-ring groove
(1)
COMECO reserves the right of changing specifications without prior notice!
Applicable for the selected probe diameter 'd' (2) Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
accessories
ANSI-FLANGED BORED THERMOWELL
YPFBA
DIMENSIONS *
Material - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes
N
H2 [mm]
H1 [mm]
F2 [mm]
d1 [mm]
F3 [mm]
F1 [mm]
3/8” NPT
20
25
28
4 / 5.5
13 / 15
≈ 24
1/2" NPT
25
30
32
7/9
17 / 19
≈ 28
3/4" NPT
30
35
35
7 / 9 / 11
17 / 19 / 21
≈ 31
INSERTION LENGTH
Probe diameter: d = d1 - 1 Probe thread: G = N Probe length (incl. thread): n = 0.98 * L - e + 0.4 * H2 (fixed) or n ≈ L - e + 0.4 * H2 (spring-loaded) Maximum temperature: 850 °C Maximum pressure: 40 bar
d1 [mm]
U [mm]
<7
max. 300
7...9
max. 500
11
max. 700
FLANGE DIMENSIONS [mm] * SIZE class 1/2"
3/4"
1"
1 ¼" L = U + b + H1 (flat face) or L = U + RF + b + H1 (raised face)
1 ½"
2"
150 300 600 150 300 600 150 300 600 150 300 600 150 300 600 150 300 600
D
k
b
88.9
60.5
95.2
66.5
98.6
69.8
9.7 12.7 14.2 11.2 14.2 15.7 12.7 16 17.5 14.2 18 20.6 16 19 22.3 17.5 20.8 25.4
117.3
82.5
108
79.2
124
88.9
117.3 133.4
98.6
127 155.4 114.3 152.4 120.6 165.1
127
RF
d2
holes
1.5 6.3
15.7 Flange type:
1.5 6.3 1.5 6.3 1.5 6.3 1.5 6.3 1.5
19
4
15.7
Maximum pressure:
19
class 150 - 150 psig class 300 - 300 psig class 600 - 600 psig
15.7 19 15.7
ANSI B16.5
4
(to fit thermowell specifications)
22.3 19
6.3
8
* Other dimensions are available on request. Please contact COMECO!
YPFBA - G4.G6.G8'/8".G9.G10.G14
Code Feature or option
Code values
G4
Probe diameter 'd' [mm]
3, 4.5, 5, 6, 8, 10
G6
Length 'U' [mm]
50…700 (see table above) (1)
G8'
Flange nominal size
50 - 1/2", 75 - 3/4", 100 - 1", 125 - 1¼", 150 - 1½", 200 - 2", Z - other (specify!) (2)
G8"
Flange nominal pressure (class)
150 - 10 bar (150 psig), 300 - 20 bar (300 psig), 600 - 40 bar (600 psig)
(1)
Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Z - other (specify!) (2)
G9
Probe thread 'N'
G10
Material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)
G14
Flange face
A - flat (FF), B - raised (RF), D - groove, F - recess, G - O-ring recess, H - O-ring groove
(1)
Applicable for the selected probe diameter 'd' (2) Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
accessories Flanged Bored Step-Tip Thermowell YPFN DIN-FLANGED BORED STEP-TIP THERMOWELL
YPFND
Material - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes
DIMENSIONS * N
H2 [mm]
H1 [mm]
F2 [mm]
d1 [mm]
F1 [mm]
F3 [mm]
M14x1.5, G3/8”
15
20 + T
22
4 / 5.5
≈ 18
13...16
M18x1.5
20
25 + T
28
7
≈ 24
15...21
M20x1.5, G1/2"
20
25 + T
30
7/9
≈ 26
15 / 17...21
M27x2, G3/4"
25
30 + T
35
7 / 9 / 11
≈ 26 / 30 15 / 17 / 21...25
INSERTION LENGTH
Probe diameter: d = d1 - 1 Probe thread: G = N Probe length (incl. thread): n = 0.98 * L - e (fixed) or n ≈ L - e + 1 (spring-loaded) Maximum temperature: 850 °C Maximum pressure: 40 bar
d1 [mm]
U [mm]
<7
max. 300
7...9
max. 700
11
max. 1000
FLANGE DIMENSIONS * NOMINAL D k b d2 SIZE [mm] [mm] [mm] [mm]
L = U + b + H1 (flat face) or L = U + b + H1 + 2 (raised face) Fillet radius at root and step 1...3 mm Full penetration weld design is also available on request
DN10 DN15 DN20 DN25 DN32 DN40 DN50
90 95 105 115 140 150 165
60 65 75 85 100 110 125
bolts
DIN 2527 or EN DIN 1092-1
14 14
4 x M12
16 18
Flange type:
Maximum pressure: PN40 18
4 x M16
20
* Other dimensions are available on request. Please contact COMECO!
Ordering code
YPFND - G4.G5.G6.G7.G8.G9.G10.G14
Code Feature or option
Code values
G4
Probe diameter 'd' [mm]
3, 4.5, 5, 6, 8, 10
G5
Insertion diameter 'F1' [mm]
13…21 (see table above) (1)
G6
Shank length 'U' [mm]
50…1000 (2) (see table above) (1)
G7
Extension length 'T' [mm]
0…100
G8
Flange nominal size
DN10 (2), DN15, DN20, DN25, DN32, DN40, DN50, Z - other (specify!) (2)
G9
Probe thread 'N' (1)
U1 - M18x1.5, U2 - M20x1.5, U3 - G3/8", U4 - G1/2", U5 - M27x2, U6 - G3/4", U8 - M14x1.5, Z - other (specify!) (2)
G10
Material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)
G14
Flange face
A - flat (FF), B - raised (RF), D - groove, F - recess, G - O-ring recess, H - O-ring groove
Applicable for the selected probe diameter 'd' (2) Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(1)
accessories
ANSI-FLANGED BORED STEP-TIP THERMOWELL
DIMENSIONS *
YPFNA N
H2 [mm]
H1 [mm]
F2 [mm]
d1 [mm]
F1 [mm]
F3 [mm]
3/8” NPT
20
25 + T
28
4 / 5.5
≈ 24
13...21
1/2" NPT
25
30 + T
32
7/9
≈ 27
15 / 17...23
3/4" NPT
30
35 + T
35
7 / 9 / 11
≈ 26 / 30
15 / 17 / 21...25
Material - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes
INSERTION LENGTH
Probe diameter: d = d1 - 1 Probe thread: G = N Probe length (incl. thread): n = 0.98 * L - e (fixed) or n ≈ L (spring-loaded) Maximum temperature: 850 °C Maximum pressure: 100 bar
d1 [mm]
U [mm]
<7
max. 300
7...9
max. 700
11
max. 1000
FLANGE DIMENSIONS [mm] * SIZE class 1/2"
3/4"
1"
1 ¼" L = U + b + H1 (flat face) or L = U + RF + b + H1 (raised face) 1 ½"
Fillet radius at root and step 1...3 mm Full penetration weld design is also available on request
2"
150 300 600 900 150 300 600 900 150 300 600 900 150 300 600 900 150 300 600 900 150 300 600 900
D
k
b
88.9
60.5
95.2
66.5
9.7 12.7 14.2 22.3 11.2 14.2 15.7 25.4 12.7 16 17.5 28.4 14.2 18 20.6 28.4 16 19 22.3 31.7 17.5 20.8 25.4 38.1
120.6 98.6
82.5 69.8
117.3
82.5
130 108
88.9 79.2
124
88.9
149.3 101.6 117.3 88.9 133.4
98.6
158.7 111.2 127 98.6 155.4 114.3 177.8 123.9 152.4 120.6 165.1
127
215.9 165.1
RF 1.5 6.3 1.5
d2
holes
15.7
1.5
ANSI B16.5
22.3 15.7 19
6.3
Flange type:
4
19 6.3 1.5
25.4 15.7
(to fit thermowell specifications)
19 6.3 1.5
25.4 15.7
4
22.3 6.3 1.5 6.3
Maximum pressure: class 150 - 150 psig class 300 - 300 psig class 600 - 600 psig class 900 - 900 psig class 1500 - 1500 psig
22.3 15.7
Dimensions for classes 900 and 1500 are identical up to 2 ½" size!
28.4 19 8 25.4
* Other dimensions are available on request. Please contact COMECO!
YPFNA - G4.G5.G6.G7.G8'/8".G9.G10.G14
Code Feature or option
(1) (2)
Code values
G4
Probe diameter 'd' [mm]
3, 4.5, 5, 6, 8, 10
G5
Insertion diameter 'F1' [mm]
13…21 (see table above) (1)
G6
Shank length 'U' [mm]
50…1000 (2) (see table above) (1)
G7
Extension length 'T' [mm]
0…100
G8'
Flange nominal size
50 - 1/2", 75 - 3/4", 100 - 1", 125 - 1¼", 150 - 1½", 200 - 2", Z - other (specify!) (2)
G8"
Flange nominal pressure (class)
150 - 10 bar (150 psig), 300 - 20 bar (300 psig), 600 - 40 bar (600 psig), 900 - 60 bar (900 psig), 1500 - 100 bar (1500 psig)
G9
Probe thread 'N' (1)
U9 - 3/8" NPT, U10 - 1/2" NPT, U11 - 3/4" NPT, Z - other (specify!) (2)
G10
Material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)
G14
Flange face
A - flat (FF), B - raised (RF), D - groove, F - recess, G - O-ring recess, H - O-ring groove
Applicable for the selected probe diameter 'd' Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
accessories Flanged Bored Straight Thermowell YPFS DIN-FLANGED BORED STRAIGHT THERMOWELL
YPFSD
Material - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes
DIMENSIONS * H2 [mm]
N
H1 [mm]
F2 [mm]
d1 [mm]
F1 [mm]
M14x1.5, G3/8”
15
20 + T
22
4 / 5.5
13…19
M18x1.5
20
25 + T
28
7
15…21
M20x1.5, G1/2"
20
25 + T
30
7/9
15…21 / 17…21
M27x2, G3/4"
25
30 + T
35
7 / 9 / 11
15…21 / 17…21 / 21
INSERTION LENGTH
Probe diameter: d = d1 - 1 Probe thread: G = N Probe length (incl. thread): n = 0.98 * L - e (fixed) or n ≈ L - e + 1 (spring-loaded) Maximum temperature: 850 °C Maximum pressure: 40 bar
d1 [mm]
U [mm]
<7
max. 300
7...9
max. 700
11
max. 1000
FLANGE DIMENSIONS * NOMINAL D k b d2 SIZE [mm] [mm] [mm] [mm]
L = U + b + H1 (flat face) or L = U + b + H1 + 2 (raised face) Fillet radius at root 1..3 mm Full penetration weld design is also available on request
Ordering code
DN10 DN15 DN20 DN25 DN32 DN40 DN50
90 95 105 115 140 150 165
60 65 75 85 100 110 125
bolts
14 14
4xM12
16 18
Flange type: DIN 2527 or EN DIN 1092-1 Maximum pressure: PN40
18
4xM16
20
* Other dimensions are available on request. Please contact COMECO!
YPFSD - G4.G5.G6.G7.G8.G9.G10.G14
Code Feature or option
Code values
G4
Probe diameter 'd' [mm]
3, 4.5, 5, 6, 8, 10
G5
Insertion diameter 'F1' [mm]
13…21 (see table above) (1)
G6
Shank length 'U' [mm]
50…1000 (2) (see table above) (1)
G7
Extension length 'T' [mm]
0…100
G8
Flange nominal size
DN10 (2), DN15, DN20, DN25, DN32, DN40, DN50, Z - other (specify!) (2)
G9
Probe thread 'N' (1)
U1 - M18x1.5, U2 - M20x1.5, U3 - G3/8", U4 - G1/2", U5 - M27x2, U6 - G3/4", U8 - M14x1.5, Z - other (specify!) (2)
G10
Material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)
G14
Flange face
A - flat (FF), B - raised (RF), D - groove, F - recess, G - O-ring recess, H - O-ring groove
Applicable for the selected probe diameter 'd' (2) Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(1)
accessories
ANSI-FLANGED BORED STRAIGHT THERMOWELL
DIMENSIONS *
YPFSA N
H2 [mm]
H1 [mm]
F2 [mm]
d1 [mm]
F1 [mm]
3/8” NPT
20
25 + T
28
4 / 5.5
13…21
1/2" NPT
25
30 + T
32
7/9
15…21 / 17…21
3/4" NPT
30
35 + T
35
7 / 9 / 11
15…21 / 17…21 / 21
Material - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes
INSERTION LENGTH
Probe diameter: d = d1 - 1 Probe thread: G = N Probe length (incl. thread): n = 0.98 * L - e (fixed) or n ≈ L (spring-loaded) Maximum temperature: 850 °C Maximum pressure: 100 bar
d1 [mm]
U [mm]
<7
max. 300
7...9
max. 700
11
max. 1000
FLANGE DIMENSIONS [mm] * SIZE class 1/2"
3/4"
1"
1 ¼" L = U + b + H1 (flat face) or L = U + RF + b + H1 (raised face) 1 ½"
Fillet radius at root 1..3 mm Full penetration weld design is also available on request
2"
150 300 600 900 150 300 600 900 150 300 600 900 150 300 600 900 150 300 600 900 150 300 600 900
D
k
b
88.9
60.5
95.2
66.5
9.7 12.7 14.2 22.3 11.2 14.2 15.7 25.4 12.7 16 17.5 28.4 14.2 18 20.6 28.4 16 19 22.3 31.7 17.5 20.8 25.4 38.1
120.6 98.6
82.5 69.8
117.3
82.5
130 108
88.9 79.2
124
88.9
149.3 117.3
101.6 88.9
133.4
98.6
158.7 127
111.2 98.6
155.4
114.3
177.8 152.4
123.9 120.6
165.1
127
215.9
165.1
RF 1.5 6.3 1.5
d2
holes
15.7
19 6.3 1.5
Flange type: ANSI B16.5
22.3 15.7 4
19 6.3 1.5
25.4 15.7
(to fit thermowell specifications)
19 6.3 1.5
25.4 15.7
4
22.3 6.3 1.5 6.3
Maximum pressure: class 150 - 150 psig class 300 - 300 psig class 600 - 600 psig class 900 - 900 psig class 1500 - 1500 psig
22.3 15.7
Dimensions for classes 900 and 1500 are identical up to 2 ½" size!
28.4 19 8 25.4
* Other dimensions are available on request. Please contact COMECO!
YPFSA - G4.G5.G6.G7.G8'/8".G9.G10.G14
Code Feature or option
Code values
G4
Probe diameter 'd' [mm]
3, 4.5, 5, 6, 8, 10
G5
Insertion diameter 'F1' [mm]
13…21 (see table above) (1)
G6
Shank length 'U' [mm]
50…1000 (2) (see table above) (1)
G7
Extension length 'T' [mm]
0…100
G8'
Flange nominal size
50 - 1/2", 75 - 3/4", 100 - 1", 125 - 1¼", 150 - 1½", 200 - 2", Z - other (specify!) (2)
G8"
Flange nominal pressure (class)
150 - 10 bar (150 psig), 300 - 20 bar (300 psig), 600 - 40 bar (600 psig)
(1)
U9 - 3/8" NPT, U10 - 1/2" NPT, U11 - 3/4" NPT, Z - other (specify!) (2)
G9
Probe thread 'N'
G10
Material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)
G14
Flange face
A - flat (FF), B - raised (RF), D - groove, F - recess, G - O-ring recess, H - O-ring groove
(1)
Applicable for the selected probe diameter 'd' (2) Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
accessories Flanged Welded Thermowell YPFW DIN-FLANGED WELDED THERMOWELL
YPFWD
DIMENSIONS * N
H [mm]
M14x1.5, G3/8”
15
18
M18x1.5
20
24
M20x1.5, G1/2"
20
26
M27x2, G3/4"
25
32
Material - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes
F2 [mm]
F1 x s [mm] 10x1.5, 10.2x2 (⅛"), 12x1.5, 13.5x2.35 (¼"), 14x2 10x1.5, 10.2x2 (⅛"), 12x1.5, 13.5x2.35, 14x2 (¼") 16x2, 17.2x2.35, 18x2, 20x2, 21.3x2.6 (½")
INSERTION LENGTH
Probe diameter: d < d1 or (F1- 2s) Probe thread: G = N Probe length (incl. thread): n = 0.98 * L - e (fixed) or n ≈ L - e (spring-loaded) Maximum temperature: 850 °C Maximum pressure: 25 bar (s = 1.5) or 40 bar (s ≥ 2)
F1 [mm]
U [mm]
≤ 12
max. 500
13...14
max. 1000
16...18
max. 1500
18...20
max. 2000
≥ 20
max. 2500
FLANGE DIMENSIONS *
L = U + b + H (flat face) or L = U + b + H + 2 (raised face)
Ordering code
NOMINAL SIZE
D [mm]
k [mm]
DN10 DN15 DN20 DN25 DN32 DN40 DN50
90 95 105 115 140 150 165
60 65 75 85 100 110 125
b d2 [mm] [mm]
bolts
Flange type: DIN 2527 or EN DIN 1092-1
14 14
4 x M12
16 18
Maximum pressure: PN10...PN40
18
4 x M16
(to fit thermowell specifications)
20
* Other dimensions are available on request. Please contact COMECO!
YPFWD - G4.G6.G8.G9.G10.G14
Code Feature or option
Code values
G4
Tube diameter 'F1' [mm]
10, 10.2 (2), 12, 13.5 (2), 14, 16, 17.2, 18, 20, 21.3
G6
Length 'U' [mm]
50…2500 (see table above) (1)
G8
Flange nominal size
DN10 (2), DN15, DN20, DN25, DN32, DN40, DN50, Z - other (specify!) (2)
G9
Probe thread 'N' (1)
U1 - M18x1.5, U2 - M20x1.5, U3 - G3/8", U4 - G1/2", U5 - M27x2, U6 - G3/4", U8 - M14x1.5, Z - other (specify!) (2)
G10
Material
M1 - 1.4301, M2 - 1.4541 (2), M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)
G14
Flange face
A - flat (FF), B - raised (RF), D - groove, F - recess, G - O-ring recess, H - O-ring groove
(1)
COMECO reserves the right of changing specifications without prior notice!
Applicable for the selected tube diameter 'F1' (2) Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
accessories
ANSI-FLANGED WELDED THERMOWELL
YPFWA
DIMENSIONS *
Material - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes
N
H [mm]
F2 [mm]
F1 x s [mm]
3/8” NPT
20
18
10x1.5, 10.2x2 (⅛"), 12x1.5, 13.5x2.35 (¼"), 14x2
1/2" NPT
25
26
10x1.5, 10.2x2 (⅛"), 12x1.5, 13.5x2.35, 14x2 (¼")
3/4" NPT
30
32
16x2, 17.2x2.35, 18x2, 20x2, 21.3x2.6 (½")
INSERTION LENGTH
Probe diameter: d < d1 or (F1- 2s) Probe thread: G = N Probe length (incl. thread): n = 0.98 * L - e + 0.4 * H (fixed) or n ≈ L - e + 0.4 * H (spring-loaded) Maximum temperature: 850 °C Maximum pressure: 25 bar (s = 1.5) or 40 bar (s ≥ 2)
F1 [mm]
U [mm]
≤ 12
max. 500
13...14
max. 1000
16...18
max. 1500
18...20
max. 2000
≥ 20
max. 2500
FLANGE DIMENSIONS [mm] * SIZE class ½"
¾"
1"
1 ¼"
1 ½"
L = U + b + H (flat face) or L = U + RF + b + H (raised face)
2"
150 300 600 150 300 600 150 300 600 150 300 600 150 300 600 150 300 600
D
k
b
88.9
60.5
95.2
66.5
98.6
69.8
9.7 12.7 14.2 11.2 14.2 15.7 12.7 16 17.5 14.2 18 20.6 16 19 22.3 17.5 20.8 25.4
117.3
82.5
108
79.2
124
88.9
117.3 133.4
98.6
127 155.4 114.3 152.4 120.6 165.1
127
RF
d2
holes
1.5 6.3
15.7 Flange type:
1.5 6.3 1.5 6.3 1.5 6.3 1.5 6.3 1.5
19
4
15.7
Maximum pressure:
19
class 150 - 150 psig class 300 - 300 psig class 600 - 600 psig
15.7 19 15.7
ANSI B16.5
4
(to fit thermowell specifications)
22.3 19
6.3
8
* Other dimensions are available on request. Please contact COMECO!
YPFWA - G4.G6.G8'/8".G9.G10.G14
Code Feature or option
(1) (2)
Code values
G4
Tube diameters 'F1' [mm]
10, 10.2 (2), 12, 13.5 (2), 14, 16, 17.2, 18, 20, 21.3
G6
Length 'U' [mm]
50…2500 (see table above) (1)
G8'
Flange nominal size
50 - ½", 75 - ¾", 100 - 1", 125 - 1¼", 150 - 1½", 200 - 2", Z - other (specify!) (2)
G8"
Flange nominal pressure (class)
150 - 10 bar (150 psig), 300 - 20 bar (300 psig), 600 - 40 bar (600 psig)
G9
Probe thread 'N' (1)
U9 - 3/8" NPT, U10 - 1/2" NPT, U11 - 3/4" NPT, Z - other (specify!) (2)
G10
Material
M1 - 1.4301, M2 - 1.4541 (2), M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)
G14
Flange face
A - flat (FF), B - raised (RF), D - groove, F - recess, G - O-ring recess, H - O-ring groove
Applicable for the selected tube diameter 'F1' Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
accessories Ceramic Protection Tubes YAC
CERAMIC PROTECTION TUBE
YAC MATERIAL
Material - alumina ceramics (see Appendix - Sheath materials) Application - T/C protection in gaseous chemical media
Maximum Temperature
CERAMIC PROTECTION TUBE (C2)
C 710
1600 °C
DIMENSIONS * F1 [mm]
d1 [mm]
Fitting Type
6 8 10 15 18 20 24 32
4.5 6 7 10 12 15 17 24
1, 5, 9 1, 5, 9 1, 5, 9 1, 5, 9 2, 5, 10 2, 6, 10 3, 6, 11 4, 7, 12
L [mm] 100÷1000
100÷2000
PROPERTIES Chemical Composition Flexural Strength
L ≈ n + m - 30
Thermal Shock Resist
good
Thermal Conductivity
20 W/m.K
Thermal Expansion
8.10-6 K-1 (0-1000 °C)
Porosity
0%
Electrical Resitivity
CERAMIC PROTECTION TUBE (C3)
C 799
1700 °C
≥ 95% Al2O3 280 MPa
6 8 10 15 18 20 24 32
4.5 6 7 10 12 15 17 24
12 > 10 Ω.m (25°C)
1, 5, 9 1, 5, 9 1, 5, 9 1, 5, 9 2, 5, 10 2, 6, 10 3, 6, 11 4, 7, 12
100÷1000
100÷2000
PROPERTIES Chemical Composition Flexural Strength
L ≈ n + m - 30
> 99.7% Al2O3 360 MPa
Thermal Shock Resist
good
Thermal Conductivity
28 W/m.K
Thermal Expansion
9.10 K (0-1200°C)
Porosity
0%
Electrical Resitivity
> 1012 Ω.m (25°C)
-6
-1
FITTING
Length 'm' [mm]
80 or 150
(1)
80 or 150 (1)
80 or 150
(1)
(1)
Material
stainless steel
stainless steel
stainless steel
TYPE
CONNECTION
1
½"
2
¾"
3
1"
4
1 ¼"
5
½"
6
¾"
7
1"
8
1 ¼"
9
½" x ½"
10
¾" x ½"
11
1" x ¾"
12
1 ¼" x ¾"
For tube length L ≥ 1000 mm
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
COMECO reserves the right of changing specifications without prior notice!
* Other dimensions are available on request. Please contact COMECO!
accessories
Ordering code
YAC - G10.G5.G6.G9'G9"
Code Feature or option Sheath material
(2)
Code values C2 - Alumina 95% (C 710), C3 - Alumina 99% (C 799)
G5
Outer diameter 'OD' [mm]
from tables overleaf
G6
Length 'L' [mm]
from tables overleaf
G9'
Fitting type
X - none, 1 - type 1, 2 - type 2, 3 - type 3, 4 - type 4, 5 - type 5, 6 - type 6, 7 - type 7, 8 - type 8, 9 - type 9, 10 - type 10, 11 - type 11, 12 - type 12, Z - other (specify!)
G9"
Fitting thread
G - parallel pipe threads, N - NPT threads, X - none *, Z - other (specify!)
Always ask for availability! * contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(2)
G10
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
accessories Metal Protection Tubes YAM YAM
Material - metals and metal alloys (see Appendix - Sheath materials) Application - temperature probe protection in athmospheres and baths
MATERIAL
Carbon Steel
WELDED PROTECTION TUBE (W)
1.4301 (AISI 304)
PROPERTIES Max. temperature Composition Thermal conductivity Composition
550 °C Mn0.8Si0.4C0.2 76 W/m.K Cr18Ni9Mn2Si1
Max. temperature
450 °C
Thermal conductivity 15 W/m.K 1.4404 (AISI 316L) 1.4571 (AISI 316Ti) 1.4841 (AISI 310)
1.4762 (AISI 446)
L
F1
S
G
Titanium
100...500
10
1
M10
Kanthal other
200...2000
~27
~3
¾"
Atmospheres: oxidizing Baths: food products, mild acids and alkalis, petroleum
Max. temperature
1150 °C
Composition
Cr25Al2Si1
Atmospheres: oxidizing, sulpurous (NOT suitable for carburizing!) Baths: molten Pb, Sn, babbitt, neutral salt baths
1100 °C 2.4816 Composition Cr16Ni72Mn1 (Inconel 600) Thermal conductivity 14 W/m.K
200...2000
21~22
~2
½"
Monel (Alloy 400)
Max. temperature
550 °C
Composition
Ni63Cu34Mn2
Thermal conductivity 22 W/m.K 1050 °C 2.4602 Composition Cr21Mo14Wo3Co (Hastelloy C) Thermal conductivity 10 W/m.K Max. temperature
Hastelloy X
Max. temperature
1200 °C
Composition
Cr22Mo10Co2Wo
Thermal conductivity 10 W/m.K
Kanthal A
Max. temperature
1250 °C
Composition
Cr22Al6
Thermal conductivity 29 W/m.K 3.7035 Titanium Grade 2
BORED PROTECTION TUBE (B)
DIMENSIONS: * [mm]
L
F1
d1
G
Titanium
100...500
14
7
M10
other
200...800
~25
9
½"
Atmospheres: oxidizing, cryogenic Baths: food products, mild acids and alkalis, petroleum
850 °C Cr17Ni11Mo2 15 W/m.K 850 °C Cr17Ni13Mo2Ti 16 W/m.K 1150 °C Cr25Ni21Mn2 16 W/m.K
Thermal conductivity 14 W/m.K
[mm]
Atmospheres: non-oxidizing Baths: petroleum, molten Zn, Mg, Pb, Sn, babbitt
Max. temperature Composition Thermal conductivity Max. temperature Composition Thermal conductivity Max. temperature Composition Thermal conductivity
Max. temperature
DIMENSIONS: *
APPLICATION
Max. temperature
600 °C
Composition
99.2% Ti
Thermal conductivity 16 W/m.K
Atmospheres: oxidizing Baths: food products, petroleum increased resistance to acids Atmospheres: oxidizing, carburizing, nitriding Baths: general applications
Atmospheres: oxidizing, nitriding, mild sulphur and carburizing (up to 550 °C) Baths: salt (cyanide) baths Atmospheres: non-oxidizing Baths: salt waters, alkalis, and acids, but NOT oxidizing acids like nitric or nitrous. Atmospheres: oxidizing, carburizing, nitriding, chlorine Baths: acids, chlorides, brine and many aggressive chemicals Atmospheres: oxidizing, carburizing, sulpurous, nitriding, chlorine Baths: general applications Atmospheres: oxidizing, carburizing, sulpurous, nitriding, ammonia Baths: molten Cu, Zn, Mg Atmospheres: high aggressive gases Baths: high aggressive solvents
Carbon Steel
see above
see above
1.4301 (AISI 304)
see above
see above
1.4404 (AISI 316L)
see above
see above
1.4571 (AISI 316Ti)
see above
see above
3.7035 Titanium Grade 2
see above
see above
Cast Iron GG-30 (ATSM A48)
Pure Iron
Max. temperature
700 °C
Composition
C3Si2Mn
Thermal conductivity 45 W/m.K Max. temperature
1300 °C
Composition
Fe
Atmospheres: oxidizing Baths: sulphur and caustic solutions some molten non-ferrous metals Baths: salt, cyanide, chloride
Thermal conductivity 80 W/m.K * Other dimensions are available on request. Please contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
COMECO reserves the right of changing specifications without prior notice!
METAL PROTECTION TUBE
accessories
Ordering code
YAM - G6.G9.G10
Code Feature or option G6
100…2000 (see tables overleaf)
Length 'L' [mm]
G9
Connection thread 'G'
G10
Material (see tables overleaf)
(1)
(2)
(2)
(1)
G - parallel pipe threads, N - NPT threads, X - none *, Z - other (specify!) M1 - 1.4301, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404(1.4435), M12 - cast iron, M13 - carbon steel, M14 - Kanthal® A, M18 - 2.4602 (Hastelloy C), M19 - Hastelloy X, M20 - Titanium alloy, M21 - Monel®, * Z - other (specify!)
Applicable for the selected design and material Always ask for availability! * contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(1)
Code values W - welded, B - bored
Design
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
accessories Ceramic Protection Tubes for Molten Metals YACM YACM
Material - silicon/carbon/alumina ceramics (see Appendix - Sheath materials) Application - T/C protection in molten metals and gaseous media
MATERIAL
Maximum Temperature
DIMENSIONS * F1 [mm]
d1 [mm]
Fitting Type
L [mm]
22
16
2, 3, 6, 11
230, 305, 460, 610, 760, 915, 1220
UCAR LT1 PROTECTION TUBE (C4) UCAR
LT1
1650 °C
PROPERTIES
Applicable metals:
L ≈ n + m - 30
Copper, Brass - up to 1150 °C Steel - up to 1375 °C (peak to 1735 °C) Zink, Lead, Tin, Silver, other metals
Chemical Composition
Non-applicable metals: Aluminum
SILICON CARBIDE PROTECTION TUBE (C5) SILICON CARBIDE
1380 °C
Flexural Strength Thermal Shock Resist
700 ∆T°C
Thermal Conductivity
29.4 W/m.K
Thermal Expansion
9.10 K (0-1000 °C)
Non-applicable metals: ferrous metals L ≈ n + m - 30
Porosity
0% conductive
20
10
2, 6, 10
25
12
3, 6, 11
30
16
4, 7, 12
40
20
8
HEXOLOY PROTECTION TUBE (C6) 1650 °C
85% SiC + 15% SiO2 250 MPa
Thermal Shock Resist
~500 ∆T°C
Thermal Conductivity
45 W/m.K
Thermal Expansion
5.10-6 K-1 (0-1200 °C)
Porosity
0.1 %
9.5
6.5
16 19 25 32 38
9.5 13 13 19 25
Non-applicable metals: ferrous metals
(Syalon 050)
150÷1370
Chemical Composition
98% SiC
Flexural Strength
380 MPa
Thermal Shock Resist
890 MPa @ 450 ∆T°C
Thermal Conductivity
30 W/m.K
Thermal Expansion
4.10-6 K-1 (0-1200 °C)
Porosity
0.6 %
Electrical Resitivity Syalon 101
107 Ω.m (25°C) 1, 5, 9 2, 5, 10 2, 6, 10 3, 6, 11 4, 7, 12 8
PROPERTIES
Aluminum, Copper, Brass, Zink, Lead, Tin, other non-ferrous metals
SYALON PROTECTION TUBE (C7)
200÷2000
Flexural Strength
Applicable metals:
L ≈ n + m - 30
200÷1000
Chemical Composition
Electrical Resitivity
SE
-1
PROPERTIES
Aluminum, Copper, Brass, Zink, Lead, Tin, other non-ferrous metals
HEXOLOY
-6
Electrical Resitivity
Applicable metals:
77%Cr + 23% Al2O3 310 MPa
1200 °C (1400 °C)
12.5
6.5
16 22 28
9 12 16
7
10 Ω.m (25°C) 200÷1000 1, 5, 9 (no groove) 2, 5, 10 3, 6, 11 4, 7, 12
150÷2000
PROPERTIES Applicable metals:
Chemical Composition
90% Si3N4 + 6% Al2O3
Aluminum, Brass, Tin, Lead, Bismuth, Cadmium, Magnesium, Cast iron
Flexural Strength
760 MPa
Non-applicable metals: Copper, ferrous metals
L ≈ n + m - 30
Thermal Shock Resist
900 ∆T°C
Thermal Conductivity
28 W/m.K
Thermal Expansion
3.10 K (0-1200°C)
Porosity
0%
Electrical Resitivity
1010 Ω.m (25°C)
-6
-1
* Other dimensions are available on request. Please contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
COMECO reserves the right of changing specifications without prior notice!
CERAMIC PROTECTION TUBE
accessories FITTING
Length 'm' [mm]
80 or 150
80 or 150
80 or 150
(1)
(1)
(1)
stainless steel
stainless steel
stainless steel
TYPE
CONNECTION
1
½"
2
¾"
3
1"
4
1 ¼"
5
½"
6
¾"
7
1"
8
1 ¼"
9
½" x ½"
10
¾" x ½"
11
1" x ¾"
12
1 ¼" x ¾"
For tube length L ≥ 1000 mm
Ordering code
YACM - G10.G5.G6.G9'G9"
Code Feature or option
Code values
G10
Sheath material (2)
C4 - UCAR LT1, C5 - silicon carbide, C6 - Hexoloy, C7 - Syalon
G5
Outer diameter 'OD' [mm]
from tables overleaf
G6
Length 'L' [mm]
from tables overleaf
G9'
Fitting type
X - none, 1 - type 1, 2 - type 2, 3 - type 3, 4 - type 4, 5 - type 5, 6 - type 6, 7 - type 7, 8 - type 8, 9 - type 9, 10 - type 10, 11 - type 11, 12 - type 12, Z - other (specify!)
G9"
Fitting thread
G - parallel pipe threads, N - NPT threads, X - none *, Z - other (specify!)
Always ask for availability! * contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(2)
(1)
Material
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org
accessories Interface Cables
Schematic
Interface
Application
side "A"
side "B"
K1
COMECO device
RS232 (PC)
Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v1.16 or higher
K2
COMECO device
RS232 (PC)
Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v1.16 or higher
K1U
COMECO device
IA250T
Configuration: TRB-B, TRBI-B Software: "TraCon" v2.0 or higher
K2U
COMECO device
IA250T
Configuration: TRB-C, TRBI-C, TRZ Software: "TraCon" v2.0 or higher
K3
COMECO device
RS232 (PC)
Configuration: TRY, old TRB-C Software: "TraCon" (1)
K3U
COMECO device
USB (PC)
Configuration: TRY Software: "TraCon" v2.0 or higher
K4
COMECO device
RS232 (PC)
Configuration: old TRB-B Software: "TraCon" (1)
K5
COMECO device
RS232 (PC)
Configuration: old TRB-B Software: "TraCon" (1)
K6
IA100 interface adapter
RS232 (PC)
Standard RS232 cable
K7
RS232
RS232 (PC)
Standard RS232 cable
K8
USB 2.0 standard
USB 2.0 standard
Standard USB cable
K9U
COMECO device
USB (PC)
Configuration and power supply: RHV, TSOJ Software: "TraCon" (1)
K10U
COMECO device with RS485
IA250N
Configuration: COMECO devices Software: "PolyMonitor"
K11U
COMECO device
USB (PC)
Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher
K12U
COMECO device
USB (PC)
Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v2.0 or higher
K13
OT801 serial printer
IA300
Configuration: IA300 data-logger Software: "InfoPrint"
K14
USB 2.0 standard
USB 2.0 standard
Standard USB cable
(1)
Contact COMECO
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Code
accessories
Code
Interface
Schematic
Application
side "A"
side "B"
K15U
COMECO device
USB (PC)
Configuration: old TRB-B Software: "TraCon" (1)
K16U
current loop
USB (PC)
Power supply: 15 VDC, max. 60 mA
COMECO device
RS232 (PC)
Configuration: TSOJ Software: "TraCon" (1)
K19U
COMECO device
USB (PC)
Configuration and power supply: TSOJ Software: "TraCon" (1)
KA1
COMECO device
K2, K2U, K5, K12U
Adapter â&#x20AC;&#x201C; simulates K1, K1U, K4, K11U Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher
KIA
INOR device
RS232 (PC)
Configuration: TRSN-C (IPAQ-L) Software: "Ipro"
KIB
INOR device
RS232 (PC)
Configuration: TRSN-B (IPAQ-H) Software: "Ipro"
KIC
INOR device
RS232 (PC)
Configuration: TRP (ProfIPAQ) Software: "ProfiSoft"
KID
INOR device
RS232 (PC)
Configuration: TRSP (IPAQ-H/L+) Software: "Ipro"
DIN43650 4-pin (F)
DB-9 (F)
K19 *
USB-A (M)
COMECO reserves the right of changing specifications without prior notice!
DIN43650 4-pin (F)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
accessories Interface Cables
Schematic
Interface
Application
side "A"
side "B"
K1
COMECO device
RS232 (PC)
Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v1.16 or higher
K2
COMECO device
RS232 (PC)
Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v1.16 or higher
K1U
COMECO device
IA250T
Configuration: TRB-B, TRBI-B Software: "TraCon" v2.0 or higher
K2U
COMECO device
IA250T
Configuration: TRB-C, TRBI-C, TRZ Software: "TraCon" v2.0 or higher
K3
COMECO device
RS232 (PC)
Configuration: TRY, old TRB-C Software: "TraCon" (1)
K3U
COMECO device
USB (PC)
Configuration: TRY Software: "TraCon" v2.0 or higher
K4
COMECO device
RS232 (PC)
Configuration: old TRB-B Software: "TraCon" (1)
K5
COMECO device
RS232 (PC)
Configuration: old TRB-B Software: "TraCon" (1)
K6
IA100 interface adapter
RS232 (PC)
Standard RS232 cable
K7
RS232
RS232 (PC)
Standard RS232 cable
K8
USB 2.0 standard
USB 2.0 standard
Standard USB cable
K9U
COMECO device
USB (PC)
Configuration and power supply: RHV, TSOJ Software: "TraCon" (1)
K10U
COMECO device with RS485
IA250N
Configuration: COMECO devices Software: "PolyMonitor"
K11U
COMECO device
USB (PC)
Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher
K12U
COMECO device
USB (PC)
Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v2.0 or higher
K13
OT801 serial printer
IA300
Configuration: IA300 data-logger Software: "InfoPrint"
K14
USB 2.0 standard
USB 2.0 standard
Standard USB cable
(1)
Contact COMECO
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Code
accessories
Code
Interface
Schematic
Application
side "A"
side "B"
K15U
COMECO device
USB (PC)
Configuration: old TRB-B Software: "TraCon" (1)
K16U
current loop
USB (PC)
Power supply: 15 VDC, max. 60 mA
COMECO device
RS232 (PC)
Configuration: TSOJ Software: "TraCon" (1)
K19U
COMECO device
USB (PC)
Configuration and power supply: TSOJ Software: "TraCon" (1)
KA1
COMECO device
K2, K2U, K5, K12U
Adapter â&#x20AC;&#x201C; simulates K1, K1U, K4, K11U Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher
KIA
INOR device
RS232 (PC)
Configuration: TRSN-C (IPAQ-L) Software: "Ipro"
KIB
INOR device
RS232 (PC)
Configuration: TRSN-B (IPAQ-H) Software: "Ipro"
KIC
INOR device
RS232 (PC)
Configuration: TRP (ProfIPAQ) Software: "ProfiSoft"
KID
INOR device
RS232 (PC)
Configuration: TRSP (IPAQ-H/L+) Software: "Ipro"
DIN43650 4-pin (F)
DB-9 (F)
K19 *
USB-A (M)
COMECO reserves the right of changing specifications without prior notice!
DIN43650 4-pin (F)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
accessories Interface Cables
Schematic
Interface
Application
side "A"
side "B"
K1
COMECO device
RS232 (PC)
Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v1.16 or higher
K2
COMECO device
RS232 (PC)
Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v1.16 or higher
K1U
COMECO device
IA250T
Configuration: TRB-B, TRBI-B Software: "TraCon" v2.0 or higher
K2U
COMECO device
IA250T
Configuration: TRB-C, TRBI-C, TRZ Software: "TraCon" v2.0 or higher
K3
COMECO device
RS232 (PC)
Configuration: TRY, old TRB-C Software: "TraCon" (1)
K3U
COMECO device
USB (PC)
Configuration: TRY Software: "TraCon" v2.0 or higher
K4
COMECO device
RS232 (PC)
Configuration: old TRB-B Software: "TraCon" (1)
K5
COMECO device
RS232 (PC)
Configuration: old TRB-B Software: "TraCon" (1)
K6
IA100 interface adapter
RS232 (PC)
Standard RS232 cable
K7
RS232
RS232 (PC)
Standard RS232 cable
K8
USB 2.0 standard
USB 2.0 standard
Standard USB cable
K9U
COMECO device
USB (PC)
Configuration and power supply: RHV, TSOJ Software: "TraCon" (1)
K10U
COMECO device with RS485
IA250N
Configuration: COMECO devices Software: "PolyMonitor"
K11U
COMECO device
USB (PC)
Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher
K12U
COMECO device
USB (PC)
Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v2.0 or higher
K13
OT801 serial printer
IA300
Configuration: IA300 data-logger Software: "InfoPrint"
K14
USB 2.0 standard
USB 2.0 standard
Standard USB cable
(1)
Contact COMECO
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Code
accessories
Code
Interface
Schematic
Application
side "A"
side "B"
K15U
COMECO device
USB (PC)
Configuration: old TRB-B Software: "TraCon" (1)
K16U
current loop
USB (PC)
Power supply: 15 VDC, max. 60 mA
COMECO device
RS232 (PC)
Configuration: TSOJ Software: "TraCon" (1)
K19U
COMECO device
USB (PC)
Configuration and power supply: TSOJ Software: "TraCon" (1)
KA1
COMECO device
K2, K2U, K5, K12U
Adapter â&#x20AC;&#x201C; simulates K1, K1U, K4, K11U Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher
KIA
INOR device
RS232 (PC)
Configuration: TRSN-C (IPAQ-L) Software: "Ipro"
KIB
INOR device
RS232 (PC)
Configuration: TRSN-B (IPAQ-H) Software: "Ipro"
KIC
INOR device
RS232 (PC)
Configuration: TRP (ProfIPAQ) Software: "ProfiSoft"
KID
INOR device
RS232 (PC)
Configuration: TRSP (IPAQ-H/L+) Software: "Ipro"
DIN43650 4-pin (F)
DB-9 (F)
K19 *
USB-A (M)
COMECO reserves the right of changing specifications without prior notice!
DIN43650 4-pin (F)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
accessories Interface Cables
Schematic
Interface
Application
side "A"
side "B"
K1
COMECO device
RS232 (PC)
Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v1.16 or higher
K2
COMECO device
RS232 (PC)
Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v1.16 or higher
K1U
COMECO device
IA250T
Configuration: TRB-B, TRBI-B Software: "TraCon" v2.0 or higher
K2U
COMECO device
IA250T
Configuration: TRB-C, TRBI-C, TRZ Software: "TraCon" v2.0 or higher
K3
COMECO device
RS232 (PC)
Configuration: TRY, old TRB-C Software: "TraCon" (1)
K3U
COMECO device
USB (PC)
Configuration: TRY Software: "TraCon" v2.0 or higher
K4
COMECO device
RS232 (PC)
Configuration: old TRB-B Software: "TraCon" (1)
K5
COMECO device
RS232 (PC)
Configuration: old TRB-B Software: "TraCon" (1)
K6
IA100 interface adapter
RS232 (PC)
Standard RS232 cable
K7
RS232
RS232 (PC)
Standard RS232 cable
K8
USB 2.0 standard
USB 2.0 standard
Standard USB cable
K9U
COMECO device
USB (PC)
Configuration and power supply: RHV, TSOJ Software: "TraCon" (1)
K10U
COMECO device with RS485
IA250N
Configuration: COMECO devices Software: "PolyMonitor"
K11U
COMECO device
USB (PC)
Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher
K12U
COMECO device
USB (PC)
Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v2.0 or higher
K13
OT801 serial printer
IA300
Configuration: IA300 data-logger Software: "InfoPrint"
K14
USB 2.0 standard
USB 2.0 standard
Standard USB cable
(1)
Contact COMECO
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Code
accessories
Code
Interface
Schematic
Application
side "A"
side "B"
K15U
COMECO device
USB (PC)
Configuration: old TRB-B Software: "TraCon" (1)
K16U
current loop
USB (PC)
Power supply: 15 VDC, max. 60 mA
COMECO device
RS232 (PC)
Configuration: TSOJ Software: "TraCon" (1)
K19U
COMECO device
USB (PC)
Configuration and power supply: TSOJ Software: "TraCon" (1)
KA1
COMECO device
K2, K2U, K5, K12U
Adapter â&#x20AC;&#x201C; simulates K1, K1U, K4, K11U Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher
KIA
INOR device
RS232 (PC)
Configuration: TRSN-C (IPAQ-L) Software: "Ipro"
KIB
INOR device
RS232 (PC)
Configuration: TRSN-B (IPAQ-H) Software: "Ipro"
KIC
INOR device
RS232 (PC)
Configuration: TRP (ProfIPAQ) Software: "ProfiSoft"
KID
INOR device
RS232 (PC)
Configuration: TRSP (IPAQ-H/L+) Software: "Ipro"
DIN43650 4-pin (F)
DB-9 (F)
K19 *
USB-A (M)
COMECO reserves the right of changing specifications without prior notice!
DIN43650 4-pin (F)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
accessories Interface Cables
Schematic
Interface
Application
side "A"
side "B"
K1
COMECO device
RS232 (PC)
Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v1.16 or higher
K2
COMECO device
RS232 (PC)
Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v1.16 or higher
K1U
COMECO device
IA250T
Configuration: TRB-B, TRBI-B Software: "TraCon" v2.0 or higher
K2U
COMECO device
IA250T
Configuration: TRB-C, TRBI-C, TRZ Software: "TraCon" v2.0 or higher
K3
COMECO device
RS232 (PC)
Configuration: TRY, old TRB-C Software: "TraCon" (1)
K3U
COMECO device
USB (PC)
Configuration: TRY Software: "TraCon" v2.0 or higher
K4
COMECO device
RS232 (PC)
Configuration: old TRB-B Software: "TraCon" (1)
K5
COMECO device
RS232 (PC)
Configuration: old TRB-B Software: "TraCon" (1)
K6
IA100 interface adapter
RS232 (PC)
Standard RS232 cable
K7
RS232
RS232 (PC)
Standard RS232 cable
K8
USB 2.0 standard
USB 2.0 standard
Standard USB cable
K9U
COMECO device
USB (PC)
Configuration and power supply: RHV, TSOJ Software: "TraCon" (1)
K10U
COMECO device with RS485
IA250N
Configuration: COMECO devices Software: "PolyMonitor"
K11U
COMECO device
USB (PC)
Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher
K12U
COMECO device
USB (PC)
Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v2.0 or higher
K13
OT801 serial printer
IA300
Configuration: IA300 data-logger Software: "InfoPrint"
K14
USB 2.0 standard
USB 2.0 standard
Standard USB cable
(1)
Contact COMECO
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Code
accessories
Code
Interface
Schematic
Application
side "A"
side "B"
K15U
COMECO device
USB (PC)
Configuration: old TRB-B Software: "TraCon" (1)
K16U
current loop
USB (PC)
Power supply: 15 VDC, max. 60 mA
COMECO device
RS232 (PC)
Configuration: TSOJ Software: "TraCon" (1)
K19U
COMECO device
USB (PC)
Configuration and power supply: TSOJ Software: "TraCon" (1)
KA1
COMECO device
K2, K2U, K5, K12U
Adapter â&#x20AC;&#x201C; simulates K1, K1U, K4, K11U Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher
KIA
INOR device
RS232 (PC)
Configuration: TRSN-C (IPAQ-L) Software: "Ipro"
KIB
INOR device
RS232 (PC)
Configuration: TRSN-B (IPAQ-H) Software: "Ipro"
KIC
INOR device
RS232 (PC)
Configuration: TRP (ProfIPAQ) Software: "ProfiSoft"
KID
INOR device
RS232 (PC)
Configuration: TRSP (IPAQ-H/L+) Software: "Ipro"
DIN43650 4-pin (F)
DB-9 (F)
K19 *
USB-A (M)
COMECO reserves the right of changing specifications without prior notice!
DIN43650 4-pin (F)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
accessories Interface Cables
Schematic
Interface
Application
side "A"
side "B"
K1
COMECO device
RS232 (PC)
Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v1.16 or higher
K2
COMECO device
RS232 (PC)
Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v1.16 or higher
K1U
COMECO device
IA250T
Configuration: TRB-B, TRBI-B Software: "TraCon" v2.0 or higher
K2U
COMECO device
IA250T
Configuration: TRB-C, TRBI-C, TRZ Software: "TraCon" v2.0 or higher
K3
COMECO device
RS232 (PC)
Configuration: TRY, old TRB-C Software: "TraCon" (1)
K3U
COMECO device
USB (PC)
Configuration: TRY Software: "TraCon" v2.0 or higher
K4
COMECO device
RS232 (PC)
Configuration: old TRB-B Software: "TraCon" (1)
K5
COMECO device
RS232 (PC)
Configuration: old TRB-B Software: "TraCon" (1)
K6
IA100 interface adapter
RS232 (PC)
Standard RS232 cable
K7
RS232
RS232 (PC)
Standard RS232 cable
K8
USB 2.0 standard
USB 2.0 standard
Standard USB cable
K9U
COMECO device
USB (PC)
Configuration and power supply: RHV, TSOJ Software: "TraCon" (1)
K10U
COMECO device with RS485
IA250N
Configuration: COMECO devices Software: "PolyMonitor"
K11U
COMECO device
USB (PC)
Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher
K12U
COMECO device
USB (PC)
Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v2.0 or higher
K13
OT801 serial printer
IA300
Configuration: IA300 data-logger Software: "InfoPrint"
K14
USB 2.0 standard
USB 2.0 standard
Standard USB cable
(1)
Contact COMECO
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Code
accessories
Code
Interface
Schematic
Application
side "A"
side "B"
K15U
COMECO device
USB (PC)
Configuration: old TRB-B Software: "TraCon" (1)
K16U
current loop
USB (PC)
Power supply: 15 VDC, max. 60 mA
COMECO device
RS232 (PC)
Configuration: TSOJ Software: "TraCon" (1)
K19U
COMECO device
USB (PC)
Configuration and power supply: TSOJ Software: "TraCon" (1)
KA1
COMECO device
K2, K2U, K5, K12U
Adapter â&#x20AC;&#x201C; simulates K1, K1U, K4, K11U Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher
KIA
INOR device
RS232 (PC)
Configuration: TRSN-C (IPAQ-L) Software: "Ipro"
KIB
INOR device
RS232 (PC)
Configuration: TRSN-B (IPAQ-H) Software: "Ipro"
KIC
INOR device
RS232 (PC)
Configuration: TRP (ProfIPAQ) Software: "ProfiSoft"
KID
INOR device
RS232 (PC)
Configuration: TRSP (IPAQ-H/L+) Software: "Ipro"
DIN43650 4-pin (F)
DB-9 (F)
K19 *
USB-A (M)
COMECO reserves the right of changing specifications without prior notice!
DIN43650 4-pin (F)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
accessories Interface Cables
Schematic
Interface
Application
side "A"
side "B"
K1
COMECO device
RS232 (PC)
Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v1.16 or higher
K2
COMECO device
RS232 (PC)
Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v1.16 or higher
K1U
COMECO device
IA250T
Configuration: TRB-B, TRBI-B Software: "TraCon" v2.0 or higher
K2U
COMECO device
IA250T
Configuration: TRB-C, TRBI-C, TRZ Software: "TraCon" v2.0 or higher
K3
COMECO device
RS232 (PC)
Configuration: TRY, old TRB-C Software: "TraCon" (1)
K3U
COMECO device
USB (PC)
Configuration: TRY Software: "TraCon" v2.0 or higher
K4
COMECO device
RS232 (PC)
Configuration: old TRB-B Software: "TraCon" (1)
K5
COMECO device
RS232 (PC)
Configuration: old TRB-B Software: "TraCon" (1)
K6
IA100 interface adapter
RS232 (PC)
Standard RS232 cable
K7
RS232
RS232 (PC)
Standard RS232 cable
K8
USB 2.0 standard
USB 2.0 standard
Standard USB cable
K9U
COMECO device
USB (PC)
Configuration and power supply: RHV, TSOJ Software: "TraCon" (1)
K10U
COMECO device with RS485
IA250N
Configuration: COMECO devices Software: "PolyMonitor"
K11U
COMECO device
USB (PC)
Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher
K12U
COMECO device
USB (PC)
Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v2.0 or higher
K13
OT801 serial printer
IA300
Configuration: IA300 data-logger Software: "InfoPrint"
K14
USB 2.0 standard
USB 2.0 standard
Standard USB cable
(1)
Contact COMECO
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Code
accessories
Code
Interface
Schematic
Application
side "A"
side "B"
K15U
COMECO device
USB (PC)
Configuration: old TRB-B Software: "TraCon" (1)
K16U
current loop
USB (PC)
Power supply: 15 VDC, max. 60 mA
COMECO device
RS232 (PC)
Configuration: TSOJ Software: "TraCon" (1)
K19U
COMECO device
USB (PC)
Configuration and power supply: TSOJ Software: "TraCon" (1)
KA1
COMECO device
K2, K2U, K5, K12U
Adapter â&#x20AC;&#x201C; simulates K1, K1U, K4, K11U Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher
KIA
INOR device
RS232 (PC)
Configuration: TRSN-C (IPAQ-L) Software: "Ipro"
KIB
INOR device
RS232 (PC)
Configuration: TRSN-B (IPAQ-H) Software: "Ipro"
KIC
INOR device
RS232 (PC)
Configuration: TRP (ProfIPAQ) Software: "ProfiSoft"
KID
INOR device
RS232 (PC)
Configuration: TRSP (IPAQ-H/L+) Software: "Ipro"
DIN43650 4-pin (F)
DB-9 (F)
K19 *
USB-A (M)
COMECO reserves the right of changing specifications without prior notice!
DIN43650 4-pin (F)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
accessories Interface Cables
Schematic
Interface
Application
side "A"
side "B"
K1
COMECO device
RS232 (PC)
Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v1.16 or higher
K2
COMECO device
RS232 (PC)
Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v1.16 or higher
K1U
COMECO device
IA250T
Configuration: TRB-B, TRBI-B Software: "TraCon" v2.0 or higher
K2U
COMECO device
IA250T
Configuration: TRB-C, TRBI-C, TRZ Software: "TraCon" v2.0 or higher
K3
COMECO device
RS232 (PC)
Configuration: TRY, old TRB-C Software: "TraCon" (1)
K3U
COMECO device
USB (PC)
Configuration: TRY Software: "TraCon" v2.0 or higher
K4
COMECO device
RS232 (PC)
Configuration: old TRB-B Software: "TraCon" (1)
K5
COMECO device
RS232 (PC)
Configuration: old TRB-B Software: "TraCon" (1)
K6
IA100 interface adapter
RS232 (PC)
Standard RS232 cable
K7
RS232
RS232 (PC)
Standard RS232 cable
K8
USB 2.0 standard
USB 2.0 standard
Standard USB cable
K9U
COMECO device
USB (PC)
Configuration and power supply: RHV, TSOJ Software: "TraCon" (1)
K10U
COMECO device with RS485
IA250N
Configuration: COMECO devices Software: "PolyMonitor"
K11U
COMECO device
USB (PC)
Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher
K12U
COMECO device
USB (PC)
Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v2.0 or higher
K13
OT801 serial printer
IA300
Configuration: IA300 data-logger Software: "InfoPrint"
K14
USB 2.0 standard
USB 2.0 standard
Standard USB cable
(1)
Contact COMECO
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Code
accessories
Code
Interface
Schematic
Application
side "A"
side "B"
K15U
COMECO device
USB (PC)
Configuration: old TRB-B Software: "TraCon" (1)
K16U
current loop
USB (PC)
Power supply: 15 VDC, max. 60 mA
COMECO device
RS232 (PC)
Configuration: TSOJ Software: "TraCon" (1)
K19U
COMECO device
USB (PC)
Configuration and power supply: TSOJ Software: "TraCon" (1)
KA1
COMECO device
K2, K2U, K5, K12U
Adapter â&#x20AC;&#x201C; simulates K1, K1U, K4, K11U Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher
KIA
INOR device
RS232 (PC)
Configuration: TRSN-C (IPAQ-L) Software: "Ipro"
KIB
INOR device
RS232 (PC)
Configuration: TRSN-B (IPAQ-H) Software: "Ipro"
KIC
INOR device
RS232 (PC)
Configuration: TRP (ProfIPAQ) Software: "ProfiSoft"
KID
INOR device
RS232 (PC)
Configuration: TRSP (IPAQ-H/L+) Software: "Ipro"
DIN43650 4-pin (F)
DB-9 (F)
K19 *
USB-A (M)
COMECO reserves the right of changing specifications without prior notice!
DIN43650 4-pin (F)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
accessories Tag Label TL TAG LABEL
TL
Material - aluminum or stainless steel (see Appendix - Sheath materials) Application - with TS and LC probes
SPECIFICATIONS * Area 2 [cm ]
Dimensions [mm]
Width [mm]
Font Size
Rows
Graphics
2...50
min. 10 (X/Y axis)
0.5...1.5
min. 8 pt
1...4
vector only
Technology: laser cut and engraved
* Exact shape, dimensions, design, and text according to customer specs!
(example)
Ordering code
TL - G1.G4.G6.G10
Code Feature or option
Code values
Number of rows
1, 2, 3, 4
G4
Area [cm2]
2â&#x20AC;Ś50
G6
Width
5 - 0.5 mm, 10 - 1.0 mm, 15 - 1.5 mm
G10
Material
AL - aluminum, M1 - 1.4301, M9 - 1.4404 (1.4435)
COMECO reserves the right of changing specifications without prior notice!
G1
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,