Comeco-GTS catalog

Page 1




temperature probes Bare Thermoresistive Sensor SR PLATINUM TEMPERATURE SENSOR Sheath - thin film. Leads - radial ø0.25 mm. Electroplated - Ag5%Pd. Accuracy class 'B' or 'A'. Sensor view

Sensor code

SRR

Technical specifications

Temperature range

H [mm]

RO [Ω]

3 ± 0.2

1.3 ± 0.2

1 × 100

T1

-50...400 °C

T11

-50...600 °C

2 ± 0.2

1.3 ± 0.2

1 × 100

T1

-50...400 °C

T11

-50...600 °C

5 ± 0.2

2 ± 0.2

1.3 ± 0.2

1 × 100

T1

-50...400 °C

T11

-50...600 °C

2.3 ± 0.2

2 ± 0.2

1.3 ± 0.2

1 × 100

T1

-50...400 °C

T11

-50...600 °C

1.3 ± 0.2

1 × 1000

T1

-50...400 °C

T11

-50...600 °C

L [mm]

B [mm]

2100

10 ± 0.2

2101

10 ± 0.2

2103 2105 2141

10 ± 0.2

2 ± 0.2

SPECIAL SENSORS 2.5 ± 0.2

2106

5 ± 0.2

2 ± 0.2

1.3 ± 0.2

1 × 50

T1

-50...400 °C

1.15

1.3 ± 0.2

1 × 100

T1

-50...400 °C

PLATINUM TEMPERATURE SENSOR Sheath - thin film. Leads - axial ø0.25 mm. Electroplated - Ag5%Pd. Accuracy class 'B' or 'A'. Sensor view

Sensor code

2105

SRA

Technical specifications L [mm]

B [mm]

H [mm]

RO [Ω]

2.3 ± 0.2

2 ± 0.2

1.4 ± 0.3

1 × 100

Temperature range

T1

-50...400 °C

PLATINUM TEMPERATURE SENSOR Sheath - thin film (SMD). Leads - for surface mounting. Accuracy class 'B' Sensor view

Sensor code

2000

SRM

Technical specifications L [mm]

B [mm]

H [mm]

RO [Ω]

3 ± 0.2

1.5 ± 0.2

0.5 ± 0.1

1 × 100

Temperature range

T12

-10...100 °C

PLATINUM TEMPERATURE SENSOR Sheath - thin film. Leads - radial ø0.25 mm. Electroplated - Ag5%Pd. Accuracy class 'B' or 'A'. Sensor view

Sensor code

SRC

Technical specifications

Temperature range

L [mm]

ø [mm]

RO [Ω]

2100

12 ± 1

4.5 ± 0.2

1 × 100

T1

-50...400 °C

T11

-50...600 °C

2102

12 ± 1

3 ± 0.2

1 × 100

T1

-50...400 °C

T11

-50...600 °C

2103

6± 1

2 ± 0.2

1 × 100

T1

-50...400 °C

T11

-50...600 °C

2202

12 ± 1

3 ± 0.2

2 × 100

T1

-50...400 °C

T11

-50...600 °C

WIRE-WOUND COPPER TEMPERATURE SENSOR Sheath - stainless steel 1.4301. Sensor view

Sensor code

SRC Technical specifications

Temperature range

L [mm]

ø [mm]

RO [Ω]

3100

25 ± 1

4 ± 0.2

50

T9

-50...200 °C

3101

32 ± 1

5 ± 0.2

50

T9

-50...200 °C

3110

40 ± 1

4 ± 0.2

1 × 100

T9

-50...200 °C

3111

80 ± 1

5 ± 0.2

1 × 100

T9

-50...200 °C

3201

32 ± 1

5 ± 0.2

T9

-50...200 °C

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

50

COMECO reserves the right of changing specifications without prior notice!

2155


temperature probes

WIRE-WOUND PLATINUM TEMPERATURE SENSOR Sheath - ceramic. Leads - pure platinum. Accuracy class 'B' or 'A'. Sensor code

ø [mm]

Leads ø [mm]

RO [Ω]

Temperature range

4301 (8301)

30 ± 0.5

4.5 - 0.03

0.40

1(2) × 100

T2

-200...850 °C

4302 (8302)

30 ± 0.5

3.8 - 0.03

0.40

1(2) × 100

T2

-200...850 °C

4251 (8251)

25 ± 0.5

3.2 - 0.03

0.40

1(2) × 100

T2

-200...850 °C

4252 (8252)

25 ± 0.5

3.0 - 0.03

0.40

1(2) × 100

T2

-200...850 °C

4253 (8253)

25 ± 0.5

2.8 - 0.03

0.40

1(2) × 100

T2

-200...850 °C

4254 (8254)

25 ± 0.5

2.4 - 0.03

0.40

1(2) × 100

T2

-200...850 °C

4255 (8255)

25 ± 0.5

1.5 - 0.03

0.27

1(2) × 100

T2

-200...850 °C

4201 (8201)

20 ± 0.5

2.0 - 0.03

0.27

1(2) × 100

T2

-200...850 °C

4151 (8151)

15 ± 0.5

4.5 - 0.03

0.40

1(2) × 100

T2

-200...850 °C

4152 (8152)

15 ± 0.5

3.2 - 0.03

0.40

1(2) × 100

T2

-200...850 °C

4153 (8153)

15 ± 0.5

3.0 - 0.03

0.40

1(2) × 100

T2

-200...850 °C

4154 (8154)

15 ± 0.5

2.8 - 0.03

0.40

1(2) × 100

T2

-200...850 °C

4155 (8155)

15 ± 0.5

2.4 - 0.03

0.40

1(2) × 100

T2

-200...850 °C

4156 (8156)

15 ± 0.5

2.0 - 0.03

0.27

1(2) × 100

T2

-200...850 °C

4157 (8157)

15 ± 0.5

1.5 - 0.03

0.27

1(2) × 100

T2

-200...850 °C

4158 (8158)*

15 ± 0.5

1.2 + 5%

0.27

1(2) × 100

T2

-200...850 °C

4159 (8159)*

15 ± 0.5

0.9 + 5%

0.15

1(2) × 100

T2

-200...850 °C

4150 (8150)*

15 ± 0.5

0.8 + 5%

0.15

1(2) × 100

T2

-200...850 °C

4101 (8101)*

10 ± 0.5

1.6 - 0.03

0.27

1(2) × 100

T2

-200...850 °C

4102 (8102)*

10 ± 0.5

1.2 + 5%

0.27

1(2) × 100

T2

-200...850 °C

4103 (8103)*

10 ± 0.5

0.8 + 5%

0.15

1(2) × 100

T2

-200...850 °C

4081 (8081)*

8 ± 0.5

1.5 - 0.03

0.27

1(2) × 100

T2

-200...850 °C

4061 (8061)*

6 ± 0.5

2.0 + 3%

0.27

1(2) × 100

T2

-200...850 °C

4041 (8041)*

4 ± 0.3

4.5 + 3%

0.40

1(2) × 100

T2

-200...850 °C

Ordering code

SR - G2.G3.G11

Code Feature or option

Technical specifications L [mm]

Code values

Variant

R, A, M, C

G2

Sensor (1)

code (from tables above)

G3

Temperature range (1)

T1 - -50…400 °C, T2 - -200…850 °C, T9 - -50…200 °C, T11 - 50…600 °C, T12 - 10…100 °C

G11

Accuracy class

A - 'A', B - 'B'

(1)

Do not code if there is only one possible for the selected variant.

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Sensor view

SRC


temperature probes Thermocouples without Sheath ST (Bare T/Cs and ceramic insulated T/Cs)

BASE METAL

Variant Material Wire diameter ('ø') [mm] Maximum temperature [°C] Isolation

J

K

Fe-CuNi

NiCr-Ni

1.0 800

1.5 800

E

NiCr-CuNi 0.5 1.0 1.5 3.0 1.5 3.0 800 1000 1100 1200 800 900 1- , 2-, or 4-hole steatite ceramic beads (max. 1200 °C) (option)

L (GOST) NiCr-CuNi 1.2 3.2 700 800

NOBLE METAL Variant

S

Material Wire diameter ('ø') [mm] Maximum temperature [°C] Isolation

Ordering code

B

C Wo5%Re-Wo26%Re 0.5 2320 none

ST - G4.(G6) - #1.#2

Code Feature or option

R

Pt10%Rh-Pt Pt13%Rh-Pt Pt30%Rh-Pt6%Rh 0.35 0.5 0.35 0.5 0.35 0.5 1600 1600 1600 1600 1800 1800 2- or 4-hole alumina ceramic rod (up to 1500, 1600, or 1700 °C) (option)

Variant

Code values J, K, E, L, S, R, B, C

(1)

G4

Wire diameter 'ø' [mm]

G6

Length [m]

length

0.35, 0.5, 1.0, 1.2, 1.5, 3.0, 3.2

#1

Isolation (1)

X - none, CZ - ceramic beads (2), C1 - ceramic rod '610' up to 1500 °C, C2 - ceramic rod '710' up to 1600 °C and up to 1 m, C3 - ceramic rod '799' up to 1700 °C

#2

Packing

X - none, R - on rolls

(1)

COMECO reserves the right of changing specifications without prior notice!

Applicable for the selected variant (2) Up to 25 m; with 1, 2, or 4 holes, depending on the variant

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

Insulation - Teflon®, silicone, fiberglass, or ceramic (see table notes) Wire leads - Cu, Ni, or Ag (see table notes)

MAXIMUM TEMPERATURE

TSEx DESIGN

RTD ELEMENT WITH LEADS

1

200 °C

INSULATION

element

LEADS

leads

outer none

DESIGN 1 (TSE1)

Teflon®

Teflon®

Teflon® silicone

2

400 °C 550 °C

3

400 °C 600 °C 800 °C

ceramic, cement

ceramic beads

4

400 °C 600 °C 800 °C

ceramic, cement

ceramic rod

L = 100 … 2000 mm

DESIGN 2 (TSE2)

SS tube, cement

glass sleeves

none glass

type

Cu stranded 0.14(22) mm2 Cu, Ni solid 0.5 mm

wires 2, 3, 4*

2x2

2, 3, 4*

2x2

2, 3, 4*

2x2

2, 3, 4*

2x2

2, 3, 4*

2x2

-

Cu, Ni, Ag solid 0.5 mm

2, 3, 4

2x2

-

Cu, Ni, Ag solid 0.5 mm

2, 3, 4

2x2

RTD element: (simplex or duplex) Pt50 (RB), Pt100 (RD), Pt500 (RF), Pt1000 (RG) Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Minimum mounting hole diameter ('d'): Wire leads

L = 100 … 2000 mm

DESIGN 3 (TSE3)

Design

2

3

4

no outer insulation

3 mm

4 mm

1

Teflon® outer insulation

4 mm

5 mm

silicone outer insulation

5 mm

6 mm

6 mm

2

no outer insulation glass outer insulation

4 mm 5 mm

5 mm

6 mm

6 mm

6 mm

3

5 mm

4

6 mm

5 mm

Outer diameter: d1 ≤ d - 0.5 mm

DESIGN 4 (TSE4)

Wire material: Cu (up to 450 °C), Ni, or Ag Insulation material: - silicone or Teflon® (max. 200 °C) - glass fiber (max. 550 °C) - SS 316 (max. 850 °C) - ceramic 610 (max. 1500 °C) Lead termination: - free (flying) leads, 10...15 mm non-insulated - ceramic base and screw terminals for heads w/ 20 mm mounting distance - ceramic base and screw terminals for heads w/ 33 mm mounting distance

L = 100 … 1000 mm * Please contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

L = 100 … 2000 mm


temperature probes

Ordering code TSE(1,2,3,4) - G1G2.G3.G4.G8.G11.G12.G13 - #1.#2 Code Feature or option

Code values

G1

Number of RTD sensors

1, 2

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000

G3

Temperature range (1)

T1 - -50…400 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C (2)

G4

Mounting hole diameter 'd' (1)

3 - ≥ 3 mm (5), 4 - ≥ 4 mm, 5 - ≥ 5 mm, 6 - ≥ 6 mm, 7 - > 6 mm

G8

Lead length 'L' [mm]

100…2000 (1)

G11

Accuracy class

A - 'A', B - 'B', C - '2xB'

G12

Number of wires (1)

2, 3, 4 (5)

G13

Wire material (1)

CU - copper (3), NI - nickel, AG - silver

#1

Additional outer lead insulation

X - none, I - mounted (4)

#2

Lead termination options

X - none (free leads), M - ceramic base and screw terminals for heads w/ 20 mm mounting distance, B - ceramic base and screw terminals for heads w/ 33 mm mounting distance

(1)

Applicable for the selected design Up to 550 °C for TSE2! Not applicable for temperatures above 450 °C! (4) Only for TSE1 and TSE2! (5) Contact COMECO!

(2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

(MI**) RTD CABLE PROBE FOR FREE MOUNTING

TSAx

Sheath - stainless steel (see table notes) Cable - see table notes

SENSITIVE ELEMENT

1 x Pt (RB,RD,RF,RG)

STRAIGHT-TUBE DESIGN (TSA)

2 x Pt (RB,RD,RF,RG) n = 20 … 200 mm

k = 1 … 10 m

1 x Cu (RH, RK) 2 x Cu (RH, RK)

DESIGN WITH ANGLED TERMINATION (TSAL)

CABLE TYPE

TEMPERATURE RANGE

SLSL, TSL, TT, YY, UU, YU

T9 T1*

GLGL

T7 T8

-50...200 °C -50...400 °C

DIMENSIONS d [mm]

wires

3*

2, 3*

4, 4.5**

2, 3*

5

2, 3*

6

2, 3, 4*

8

2, 3, 4

0...200 °C 0...400 °C

TT

T22 -200...200 °C

6, 8

SLSL, TSL, YY, UU, YU

T9

-50...200 °C

GLGL, TT

T7

0...200 °C

2x2, 2x3*

5*

2, 3*

6

2, 3, 4*

8

2, 3, 4

6, 8

2x2, 2x3*

1 x PTC (RP, RQ)

SLSL, TSL, YY, UU, YU

T12

-50...100 °C

6

2, 3

2 x PTC (RP, RQ)

GLGL, TT

T19

0...100 °C

8

2x2

Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Applicable cables: n = 20 … 200 mm

k = 1 … 10 m

Probe design Temp. range T12, T19

BENDED-TUBE DESIGN (TSAB)

TSA, TSAB

TSAL

all

all

T7, T9 T22

no PUR, no PVC TT

TT, SLSL, TSL

T1, T8

GLGLP

no PUR, no PVC

Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes)

Cable connector: 4-pin (C3) (see Appendix - Connectors) n = 20 … 200 mm m = 30 ... 200 mm

k = 1 … 10 m * Please contact COMECO! ** Available only for TSAL!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance)


temperature probes

Ordering code

TSA(L,B) - (MI -(1)) G1G2.G3.G4.G6.G7.G8.G10.G11.G12.G14.G15 - #1

Code Feature or option

Code values

G1

Number of RTD sensors

1 or 2

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP - PTC 1k, RQ - PTC 2k

G3

Temperature range

T1 - -50…400 °C, T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T12 - 50…100 °C, T19 - 0…100 °C, T22 - -200…200 °C

G4

Diameter 'd' [mm]

G6

Probe length 'n' [mm]

regular design

4, 5, 6, 8

MI design

3 (5), 4.5, 6, 8 20…200

(2)

G7

Probe length 'm' [mm]

G8

Cable length 'k' [m] and type

G10

Sheath material (wetted parts)

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

G11

Accuracy class

X - none (3), A - 'A', B - 'B', C - '2xB'

G12

Number of wires

2, 3, 4 (5)

G14

Tip shape

X - standard closed, N - narrowed (4), P - pitted (4)

G15

Connector

X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only)

Options

X - none, OV - vibration proof (MgO or Silicone filled) (4), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface (4)

#1

30…200 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (5), 1PV…10PV - PVC

(1)

Available only for TSAL! Only for TSAB! For non-Pt sensors (4) Only for non-MI (regular) design! (5) Contact COMECO!

(2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

(MI**) T/C CABLE PROBE FOR FREE MOUNTING

TSAx

Sheath - stainless steel (see table notes) Cable - see table notes

SENSITIVE ELEMENT

CABLE TYPE

DIMENSIONS

TEMPERATURE RANGE

d [mm]

wires

Regular Design

STRAIGHT-TUBE DESIGN (TSA) 1xK

n = 20 … 200 mm

k = 1 … 10 m

1 x J, 1xT

SLSL, TSL, YY, UU, YU

T9 T1*

GLGL, TT, SFSF

T7 T8

-50...200 °C -50...400 °C 0...200 °C 0...400 °C

T4*

0...800 °C

SLSL, TSL, YY, UU, YU

T9 T1*

-50...200 °C -50...400 °C

GLGL, TT, SFSF

T7 T8

4, 5, 6, 8

2

4, 5, 6, 8

2

3, 4.5, 6, 8

2

3, 4.5, 6, 8

2

0...200 °C 0...400 °C

MI Design **

DESIGN WITH ANGLED TERMINATION (TSAL)

SLSL, TSL, YY, UU, YU

T9 T1*

GLGL, TT, SFSF

T7 T8

-50...200 °C -50...400 °C

1 x N, 1xE

0...200 °C 0...400 °C

T4*

0...800 °C

SLSL, TSL, YY, UU, YU

T9 T1*

-50...200 °C -50...400 °C

GLGL, TT, SFSF

T7 T8

1xT 0...200 °C 0...400 °C

Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9), 1.4841 (M5), 2.4816 (M8) k = 1 … 10 m

BENDED-TUBE DESIGN (TSAB)

Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) - SFSF (mineral fiber, max. 1000 °C ambient temperature) Applicable cables: Probe design Temp. range T7, T9 T1, T8 T4

n = 20 … 200 mm m = 30 ... 200 mm

k = 1 … 10 m

TSA, TSAB

TSAL

no PUR, no PVC

all

GLGLP, SFSF

no PUR, no PVC

SFSF

GLGLP, SLSL*, TSL*

Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors)

* Please contact COMECO! ** Available only for TSAL!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

n = 20 … 200 mm


temperature probes

Ordering code

TSA(L,B) - (MI -(1)) G2.G3.G4.G6.G7.G8.G10.G11.G14.G15 - #1

Code Feature or option

Code values regular design

J - type "J", K - type "K", T - type "T"

G2

Thermocouple

G3

Temperature range

G4

Diameter 'd' [mm]

G6

Probe length 'n' [mm]

20…200

G7

Probe length 'm' [mm] (2)

30…200

G8

Cable length 'k' [m] and type

1GL…10GL - glass fiber, 1MF…10MF - mineral fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1PV…10PV - PVC

G10

Sheath material (wetted parts)

G11

Accuracy class

1 - '1' (4), 2 - '2'

G14

Tip shape (hot junction)

X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design

G15

Connector

X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector

#1

Options

X - none, OV - vibration proof (MgO or Silicone filled) (3), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface (3)

MI design

E - type "E", N - type "N", T - type "T" T1 - -50…400 °C, T4 - 0…800 °C (4), T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C

regular design MI design

4 (4), 5, 6, 8 3, 4.5, 6, 8

regular design

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

MI design

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404

(1)

Available only for TSAL! Only for TSAB! Only for non-MI (regular) design! (4) Contact COMECO!

(2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

(MI**) RTD CABLE PROBE FOR FREE MOUNTING

TSAx

Sheath - stainless steel (see table notes) Cable - see table notes

SENSITIVE ELEMENT

1 x Pt (RB,RD,RF,RG)

STRAIGHT-TUBE DESIGN (TSA)

2 x Pt (RB,RD,RF,RG) n = 20 … 200 mm

k = 1 … 10 m

1 x Cu (RH, RK) 2 x Cu (RH, RK)

DESIGN WITH ANGLED TERMINATION (TSAL)

CABLE TYPE

TEMPERATURE RANGE

SLSL, TSL, TT, YY, UU, YU

T9 T1*

GLGL

T7 T8

-50...200 °C -50...400 °C

DIMENSIONS d [mm]

wires

3*

2, 3*

4, 4.5**

2, 3*

5

2, 3*

6

2, 3, 4*

8

2, 3, 4

0...200 °C 0...400 °C

TT

T22 -200...200 °C

6, 8

SLSL, TSL, YY, UU, YU

T9

-50...200 °C

GLGL, TT

T7

0...200 °C

2x2, 2x3*

5*

2, 3*

6

2, 3, 4*

8

2, 3, 4

6, 8

2x2, 2x3*

1 x PTC (RP, RQ)

SLSL, TSL, YY, UU, YU

T12

-50...100 °C

6

2, 3

2 x PTC (RP, RQ)

GLGL, TT

T19

0...100 °C

8

2x2

Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Applicable cables: n = 20 … 200 mm

k = 1 … 10 m

Probe design Temp. range T12, T19

BENDED-TUBE DESIGN (TSAB)

TSA, TSAB

TSAL

all

all

T7, T9 T22

no PUR, no PVC TT

TT, SLSL, TSL

T1, T8

GLGLP

no PUR, no PVC

Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes)

Cable connector: 4-pin (C3) (see Appendix - Connectors) n = 20 … 200 mm m = 30 ... 200 mm

k = 1 … 10 m * Please contact COMECO! ** Available only for TSAL!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance)


temperature probes

Ordering code

TSA(L,B) - (MI -(1)) G1G2.G3.G4.G6.G7.G8.G10.G11.G12.G14.G15 - #1

Code Feature or option

Code values

G1

Number of RTD sensors

1 or 2

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP - PTC 1k, RQ - PTC 2k

G3

Temperature range

T1 - -50…400 °C, T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T12 - 50…100 °C, T19 - 0…100 °C, T22 - -200…200 °C

G4

Diameter 'd' [mm]

G6

Probe length 'n' [mm]

regular design

4, 5, 6, 8

MI design

3 (5), 4.5, 6, 8 20…200

(2)

G7

Probe length 'm' [mm]

G8

Cable length 'k' [m] and type

G10

Sheath material (wetted parts)

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

G11

Accuracy class

X - none (3), A - 'A', B - 'B', C - '2xB'

G12

Number of wires

2, 3, 4 (5)

G14

Tip shape

X - standard closed, N - narrowed (4), P - pitted (4)

G15

Connector

X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only)

Options

X - none, OV - vibration proof (MgO or Silicone filled) (4), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface (4)

#1

30…200 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (5), 1PV…10PV - PVC

(1)

Available only for TSAL! Only for TSAB! For non-Pt sensors (4) Only for non-MI (regular) design! (5) Contact COMECO!

(2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

(MI**) T/C CABLE PROBE FOR FREE MOUNTING

TSAx

Sheath - stainless steel (see table notes) Cable - see table notes

SENSITIVE ELEMENT

CABLE TYPE

DIMENSIONS

TEMPERATURE RANGE

d [mm]

wires

Regular Design

STRAIGHT-TUBE DESIGN (TSA) 1xK

n = 20 … 200 mm

k = 1 … 10 m

1 x J, 1xT

-50...200 °C -50...400 °C

SLSL, TSL, YY, UU, YU

T9 T1*

GLGL, TT, SFSF

T7 T8

0...200 °C 0...400 °C

T4*

0...800 °C

SLSL, TSL, YY, UU, YU

T9 T1*

-50...200 °C -50...400 °C

GLGL, TT, SFSF

T7 T8

4, 5, 6, 8

2

4, 5, 6, 8

2

3, 4.5, 6, 8

2

3, 4.5, 6, 8

2

0...200 °C 0...400 °C

MI Design **

DESIGN WITH ANGLED TERMINATION (TSAL)

SLSL, TSL, YY, UU, YU

T9 T1*

GLGL, TT, SFSF

T7 T8

-50...200 °C -50...400 °C

1 x N, 1xE

0...200 °C 0...400 °C

T4*

0...800 °C

SLSL, TSL, YY, UU, YU

T9 T1*

-50...200 °C -50...400 °C

GLGL, TT, SFSF

T7 T8

1xT 0...200 °C 0...400 °C

Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9), 1.4841 (M5), 2.4816 (M8) k = 1 … 10 m

BENDED-TUBE DESIGN (TSAB)

Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) - SFSF (mineral fiber, max. 1000 °C ambient temperature) Applicable cables: Probe design Temp. range T7, T9 T1, T8 T4

n = 20 … 200 mm m = 30 ... 200 mm

k = 1 … 10 m

TSA, TSAB

TSAL

no PUR, no PVC

all

GLGLP, SFSF

no PUR, no PVC

SFSF

GLGLP, SLSL*, TSL*

Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors)

* Please contact COMECO! ** Available only for TSAL!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

n = 20 … 200 mm


temperature probes

Ordering code

TSA(L,B) - (MI -(1)) G2.G3.G4.G6.G7.G8.G10.G11.G14.G15 - #1

Code Feature or option

Code values regular design

J - type "J", K - type "K", T - type "T"

G2

Thermocouple

G3

Temperature range

G4

Diameter 'd' [mm]

G6

Probe length 'n' [mm]

20…200

G7

Probe length 'm' [mm] (2)

30…200

G8

Cable length 'k' [m] and type

1GL…10GL - glass fiber, 1MF…10MF - mineral fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1PV…10PV - PVC

G10

Sheath material (wetted parts)

G11

Accuracy class

1 - '1' (4), 2 - '2'

G14

Tip shape (hot junction)

X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design

G15

Connector

X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector

#1

Options

X - none, OV - vibration proof (MgO or Silicone filled) (3), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface (3)

MI design

E - type "E", N - type "N", T - type "T" T1 - -50…400 °C, T4 - 0…800 °C (4), T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C

regular design MI design

4 (4), 5, 6, 8 3, 4.5, 6, 8

regular design

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

MI design

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404

(1)

Available only for TSAL! Only for TSAB! Only for non-MI (regular) design! (4) Contact COMECO!

(2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes SCREW-IN CABLE PROBE

TSAGx

Sheath - stainless steel (see table notes) Cable - see table notes

SENSITIVE ELEMENT

CABLE TYPE

TEMPERATURE RANGE

DIMENSIONS d [mm]

wires

RTD Design

STRAIGHT DESIGN WITH WELDED CONNECTION (TSAG)

1 x Pt (RB,RD,RF,RG) 2 x Pt (RB,RD,RF,RG) 1 x Cu (RH, RK)

n = 15 … 200 mm k = 1 … 10 m

STRAIGHT DESIGN WITH MOVABLE CONNECTION (TSAG2)

2 x Cu (RH, RK)

-50...200 °C -50...400 °C

4, 5

2, 3*

6

2, 3, 4*

0...200 °C 0...400 °C

8

2, 3, 4

SLSL, TSL, YY, UU, YU

T9 T1*

GLGL, TT

T7 T8

TT

T22 -200...200 °C

SLSL, TSL, YY, UU, YU

T9

-50...200 °C

GLGL, TT

T7

0...200 °C

2x2,

6, 8

2x3*

5*

2, 3*

6

2, 3, 4*

8

2, 3, 4 2x2,

6 ,8

2x3*

1 x PTC (RP, RQ)

SLSL, TSL, YY, UU, YU

T12

-50...100 °C

6

2, 3

2 x PTC (RP, RQ)

GLGL, TT

T19

0...100 °C

8

2x2

1 x K,

SLSL, TSL, YY, UU, YU

T9 T1*

-50...200 °C -50...400 °C

GLGL, TT, SFSF

T8 T4 T3*

0...400 °C 0...800 °C 0...850 °C

5, 6, 8

2

1 x J,

SLSL, TSL, YY, UU, YU

T9 T1*

-50...200 °C -50...400 °C

1xT

GLGL, TT, SFSF

T8 T4*

0...400 °C 0...800 °C

5, 6, 8

2

Thermocouple Design

1 x N, 1xE m = 30 … 100 mm k = 1 … 10 m

n = 10 … 200 mm

ANGLED DESIGN WITH WELDED CONNECTION (TSAGL)

Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) - SFSF (mineral fiber, max. 1000 °C ambient temperature) Applicable cables:

k = 1 … 10 m

ANGLED DESIGN WITH MOVABLE CONNECTION (TSAGL2)

TSAG, TSAG2 all no PUR, no PVC TT GLGLP, SFSF SFSF

TSAGL, TSAGL2 all TT, SLSL, TSL no PUR, no PVC GLGLP, SFSF

Tip shape: - RTD: standard, narrowed, pitted - T/C: standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors) Available threads and HEX sizes: n = 10 … 200 mm m = 50 … 100 mm

k = 1 … 10 mm

G SW

M6

M8

10

10

M10 1/8" 12(13)

* Please contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

M12 1/4" 14

M14 17

M16 3/8" 19

M18 22

M20 1/2" 24

COMECO reserves the right of changing specifications without prior notice!

n = 15 … 200 mm

Probe design Temp. range T12, T19 T7, T9 T22 T1, T8 T3, T4


temperature probes

Ordering code

TSAG(2,L,L2) - G1G2.G3.G4.G6.G7.G8.G9.G10.G11.G12.G14.G15 - #1

Code Feature or option

Code values

G1

Number of sensors

1 or 2

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP -PTC 1k, RQ - PTC 2k, J - T/C type "J", K - T/C type "K", T - T/C type "T"

G3

Temperature range

T1 - -50…400 °C, T3 - 0…850 °C (4), T4 - 0…800 °C (4), T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T12 - 50…100 °C, T19 - 0…100 °C, T22 - -200…200 °C

G4

Diameter 'd' [mm]

G6

Probe length 'n' [mm]

10…200 (see tables overleaf)

G7

Probe length 'm' [mm] (1)

30…100 (see tables overleaf)

G8

Cable length 'k' [m] and type

1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1MF…10MF - mineral fiber, 1PV…10PV - PVC

G9

Mounting connection

Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q7 - M12x1.5, Q8 - M14x1.5, Q10 - 1/2" NPT, Q18 - G1/8", Q19 - 1/8" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Q26 - M8x1, Q29 - M8x1.25, Q30 - M10x1.5, Q31 - M6x1, Uxx - union nut (xx - same as for Qxx)

G10

Sheath material (wetted parts)

G11

Accuracy class

RTD

4, 5, 6, 8

T/C

5, 6, 8

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

RTD

X - none (2), A - 'A', B - 'B', C - '2xB'

T/C

1 - '1' (4), 2 - '2'

(3)

2, 3, 4 (4)

G12

Number of wires

G14

Tip shape

G15

Connector

X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector

#1

Options

X - none, OV - vibration proof (MgO or Silicone filled), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface

RTD

X - standard closed, N - narrowed, P - pitted

T/C

X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design

(1)

Only for TSAG2 and TSAGL2! For non-Pt sensors Only for RTD sensors! (4) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

SPRING THERMOCOUPLE FOR SURFACE MEASUREMENT

TSAS

Sheath - stainless steel (see table notes) Extension cable - see table notes

SENSITIVE ELEMENT 1 x J, 1xT 1 x K, 1xN

TEMPERATURE RANGE

DIMENSIONS WIRE [mm]

d [mm]

T8

0...400 °C

0.5

10, 12

T4

0...800 °C

0.5

10, 12

Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9)

n = 80 … 160 mm

k = 1 ... 10 m

Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) Tip shape: exposed hot junction, flat-surfaced (see Appendix - Tip Shapes) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) Thermocouple connector: 'standard' (C5) or 'miniature' (C6) (see Appendix - Connectors)

TSAS - G2.G3.G4.G6.G8.G10.G11.G15 - #1

Code Feature or option G2

Thermocouple

Code values J - type "J", K - type "K", T - type "T", N - type "N"

G3

Temperature range

T4 - 0…800 °C, T8 - 0…400 °C

G4

Diameter 'd' [mm]

10, 12

G6

Probe length 'n' [mm]

80…160

G8

Cable length 'k' [m] and type

1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®

G10

Sheath material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

G11

Accuracy class

1 - '1' (1), 2 - '2'

G15

Connector

X - none, C5 - T/C connector, C6 - miniature T/C connector

Options

X - none, OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface

#1 (1)

Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code


temperature probes

CABLE PROBE WITH SCREW FIXING FOR SURFACE MEASUREMENT

TSAT

DIMENSIONS SENSITIVE ELEMENT

Sheath - stainless steel (see table notes) Cable - see table notes

CABLE TYPE

TEMPERATURE RANGE

d [mm]

wires

4, 5

2, 3*

6

2, 3, 4*

6

2x2

6

2, 3

4, 5, 6

2

RTD Design 1 x Pt (RB,RD,RF,RG) 2 x Pt (RB,RD,RF,RG) 1 x PTC (RP, RQ)

-50...200 °C -50...100 °C

SLSL, TSL, TT, YY, UU, YU

T9 T12

GLGL

T7 T8

TT

T22 -200...200 °C

SLSL, TSL, YY, UU, YU

T12

-50...100 °C

GLGL, TT

T19

0...100 °C

0...200 °C 0...400 °C

Thermocouple Design T9

-50...200 °C

1 x J,

SLSL, TSL, YY, UU, YU

1xT

GLGL, TT

T8

0...400 °C

1 x K,

n = 20 … 30 mm

k = 1 … 10 m

d

4

5

6

6x6

7x7

8x8

D

3

3, 4

3, 4, 5

Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Tip shape: - RTD: standard - T/C: standard (isolated) or grounded (see Appendix - Tip Shapes) Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors)

COMECO reserves the right of changing specifications without prior notice!

* Please contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

Ordering code

TSAT - G1G2.G3.G4.G5.G6.G8.G10.G11.G12.G14.G15 - #1

Code Feature or option

Code values

G1

Number of sensors

1 or 2

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RP -PTC 1k, RQ - PTC 2k, J - T/C type "J", K - T/C type "K", T - T/C type "T"

G3

Temperature range

T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T12 - 50…100 °C, T19 - 0…100 °C, T22 - -200…200 °C

G4

Diameter 'd' [mm]

4, 5, 6 (1)

G5

Diameter 'D' [mm]

G6

Probe length 'n' [mm]

20…30

G8

Cable length 'k' [m] and type

1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (5), 1PV…10PV - PVC

G10

Sheath material (wetted parts)

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

G11

Accuracy class

G12

Number of wires (3)

G14

Tip shape (hot junction)

3, 4, 5

RTD

X - none (2), A - 'A', B - 'B', C - '2xB'

T/C

1 - '1' (5), 2 - '2' 2, 3, 4 (5)

(4)

X - standard (isolated from sheath), G - grounded

G15

Connector

X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector

#1

Options

X - none, OV - vibration proof (MgO or Silicone filled), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface

(1)

Applicable for the selected diameter 'd' For non-Pt sensors Only for RTD sensors! (4) Only for thermocouples! (5) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

CERAMIC PROBE WITH EXTENSION CABLE

TSAZx

DIMENSIONS SENSITIVE ELEMENT

Sheath - ceramic (see table notes) Holding tube - stainless steel 1.4301 or 1.4541 Extension cable - see table notes

TEMPERATURE RANGE T13

DESIGN WITH HOLDING TUBE (TSAZ1)

1 x K,

T16

WIRE [mm] MI [mm]

0...1000 °C

1.0

0...1100 °C

MI 3.0, 4.5 (Inconel 600)

1xN

n [mm]

50...300; 310…600

T6

0...1200 °C

MI 3.0, 4.5 (Nicrobell®)

1xS

T5

0...1500 °C

0.35

100...300;

1xR

T14

0...1600 °C

0.5

310…600

T14

0...1600 °C

0.35

100...300;

T15

0...1700 °C

0.5

310…600

1xB

Ceramic sheath material: Oxal 710 (C2), Alsint 799 (C3), Hexoloy® (C6) (see Appendix - Sheath Materials)

DESIGN WITH HIGH-TEMPERATURE CABLE (TSAZ2)

Cable type: - SLSL or TSL (silicone, max. 250 °C ambient temperature) - GLGLP (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SFSF (mineral fiber, max. 1000 °C ambient temperature) - KFKF (ceramic fiber, max. 1200 °C ambient temperature) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)

k = 1 … 10 mm

Thermocouple connector: 'standard' (C5) or 'miniature' (C6) (see Appendix - Connectors) * Please contact COMECO!

TSAZ(1,2) - G2.G3.G6.G8.G10.G11.G15 - #1

Code Feature or option G2

Code values

Thermocouple

K - type "K", N - type "N", S - type "S", R - type "R", B - type "B"

G3

Temperature range

T5 - 0…1500 °C, T6 - 0…1200 °C, T13 - 0…1000 °C, T14 - 0…1600 °C, T15 - 0…1700 °C, T16 - 0…1100 °C

G6

Probe length 'n' [mm]

G8

Cable length 'k' [m] and type

1GL…10GL - glass fiber, 1SL…10SL - silicone, 1MF…10MF - mineral fiber, 1CF…10CF - ceramic fiber

G10

Sheath material

C2 - ceramic Oxal 710, C3 - ceramic Alsint 799, C6 - Hexoloy®

G11

Accuracy class

1 - '1' (1), 2 - '2'

G15

Connector

X - none, C5 - T/C connector, C6 - miniature T/C connector

#1

Options

X - none, OB - braid termination lead (only w/o connector)

(1)

T/Cs "K", "N'

50…600

T/Cs "S", "R", "B"

100…600

Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code


temperature probes (MI**) RTD BAYONET CABLE PROBE

TSBx

Sheath - stainless steel (see table notes) Cable - see table notes STRAIGHT-TUBE DESIGN (TSB)

SENSITIVE ELEMENT 1 x Pt (RB,RD,RF,RG)

2 x Pt (RB,RD,RF,RG) 1 x Cu (RH, RK)

n = 10 … 200 mm k = 1 … 10 m

2 x Cu (RH, RK)

CABLE TYPE

TEMPERATURE RANGE

DIMENSIONS d [mm]

wires

SLSL, TSL, TT YY, UU, YU

T7 T9

0...200 °C -50...200 °C

4, 4.5**, 5

2, 3*

6

2, 3, 4*

SLSL, TSL, TT, GLGL

T1 T8

-50...400 °C 0...400 °C

8

2, 3, 4

GLGL, SFSF TT, TSL, SLSL

T11* -50...600 °C T22 -200...200 °C

6, 8

SLSL, TSL, YY, UU, YU

T9

-50...200 °C

GLGL, TT

T7

0...200 °C

2x2, 2x3*

5*

2, 3*

6

2, 3, 4*

8

2, 3, 4

6, 8

2x2, 2x3*

1 x PTC (RP, RQ)

SLSL, TSL, YY, UU, YU

T12

-50...100 °C

6

2, 3

2 x PTC (RP, RQ)

GLGL, TT

T19

0...100 °C

8

2x2

DESIGN WITH ANGLED TERMINATION (TSBL) Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) - SFSF (mineral fiber, max. 1000 °C ambient temperature) Applicable cables: n = 10 … 200 mm k = 1 … 10 m

STRAIGHT DESIGN WITH MOVABLE CONNECTION (TSBG)

Probe design Temp. range

TSB, TSBG

T12, T19

TSBL, TSBGL

all

all

T7, T9

no PUR, no PVC

T22 T1, T8

GLGLP, SFSF

TT, SLSL, TSL no PUR, no PVC

SFSF

GLGLP, SFSF

TT

T11

Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes)

n = 10 … 200 mm k = 1 … 10 m

Cable connector: 4-pin (C3) (see Appendix - Connectors) Bayonet: ø13x1... ø20x1; aluminum, brass, or stainless steel

ANGLED DESIGN WITH MOVABLE CONNECTION (TSBGL) Available threads and HEX sizes: G SW

M8

M10 1/8"

M12 1/4"

M14

M16 3/8"

M18

M20 1/2"

10

12(13)

14

17

19

22

24

* Please contact COMECO! n = 10 … 200 mm k = 1 … 10 m

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

** Available only for TSBL and TSBGL!

COMECO reserves the right of changing specifications without prior notice!

Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance)


temperature probes

Ordering code

TSB(L,G,GL) - (MI -(1)) G1G2.G3.G4.G5'5".G6.G8.G9.G10.G11.G12.G14.G15 - #1

Code Feature or option

Code values

G1

Number of RTD sensors

1 or 2

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP -PTC 1k, RQ - PTC 2k

G3

Temperature range

T1 - -50…400 °C, T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T11 - -50…600 °C (1,2,7), T12 - 50…100 °C, T19 - 0…100 °C, T22 - -200…200 °C

G4

Diameter 'd' [mm]

G5'

Bayonet size (3)

regular design

4, 5, 6, 8

MI design

4.5, 6, 8 (7) 13 - ø13x1, 14 - ø14x1, 15 - ø15x1, 17 - ø17x1, 20 - ø20x1, Z - other (specify!)

(3)

G5"

Bayonet material

G6

Probe length 'n' [mm]

10…200

G8

Cable length 'k' [m] and type

1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (7), 1MF…10MF - mineral fiber, 1PV…10PV - PVC

G9

Mounting connection (4)

Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q7 - M12x1.5, Q8 - M14x1.5, Q10 - 1/2" NPT, Q18 - G1/8", Q19 - 1/8" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Q26 - M8x1, Q29 - M8x1.25, Q30 - M10x1.5, Uxx - union nut (xx - same as for Qxx)

G10

Sheath material (wetted parts)

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

G11

Accuracy class

X - none (5), A - 'A', B - 'B', C - '2xB'

G12

Number of wires

2, 3, 4 (7)

G14

Tip shape

X - standard closed, N - narrowed (6), P - pitted (6)

G15

Connector

X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only)

Options

X - none, OV - vibration proof (MgO or Silicone filled) (6), OS - cable protection SS spring (≈ 50 mm) (1), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface (6)

#1

AL - aluminum, BR - brass, SS - stainless steel

(1)

Available only for TSBL and TSBGL! Available only for MI design! Only for TSB and TSBL! (4) Only for TSBG and TSBGL! (5) For non-Pt sensors (6) Only for non-MI (regular) design! (7) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes (MI**) T/C BAYONET CABLE PROBE

TSBx

Sheath - stainless steel (see table notes) Cable - see table notes

SENSITIVE ELEMENT

CABLE TYPE

DIMENSIONS

TEMPERATURE RANGE

d [mm]

wires

Regular Design

STRAIGHT-TUBE DESIGN (TSB) 1xK

1xJ n = 10 … 200 mm k = 1 … 10 m

1xT

SLSL, TSL, TT YY, UU, YU

T7 T9

0...200 °C -50...200 °C

SLSL, TSL, TT, GLGL

T1 T8

-50...400 °C 0...400 °C

GLGL, SFSF

T4 T3*

SLSL, TSL, TT YY, UU, YU

T7 T9

0...200 °C -50...200 °C

SLSL, TSL, TT, GLGL

T1 T8

-50...400 °C 0...400 °C

GLGL, SFSF

T4*

YY, UU, YU SLSL, TSL, TT GLGL

T7 T9

DESIGN WITH ANGLED TERMINATION (TSBL)

1xE

1xT

STRAIGHT DESIGN WITH MOVABLE CONNECTION (TSBG)

2

4, 5, 6, 8

2

4, 5, 6, 8

2

4.5, 6, 8

2

4.5, 6, 8

2

0...800 °C 0...850 °C

0...800 °C 0...200 °C -50...200 °C

MI Design **

1 x N,

n = 10 … 200 mm k = 1 … 10 m

4, 5, 6, 8

SLSL, TSL, TT YY, UU, YU

T7 T9

0...200 °C -50...200 °C

SLSL, TSL, TT, GLGL

T1 T8

-50...400 °C 0...400 °C

GLGL, SFSF

T4 T3*

YY, UU, YU SLSL, TSL, TT GLGL

T7 T9

0...800 °C 0...850 °C 0...200 °C -50...200 °C

Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9), 1.4841 (M5), 2.4816 (M8) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) - SFSF (mineral fiber, max. 1000 °C ambient temperature) Applicable cables:

n = 10 … 200 mm k = 1 … 10 m

ANGLED DESIGN WITH MOVABLE CONNECTION (TSBGL)

TSB, TSBG

TSBL, TSBGL

T7, T9

no PUR, no PVC

all

T1, T8

GLGLP, SFSF

no PUR, no PVC

T3, T4

SFSF

GLGLP, SFSF

Tip shape: standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors) Bayonet: ø13x1... ø20x1; aluminum, brass, or stainless steel Available threads and HEX sizes: G SW

n = 10 … 200 mm k = 1 … 10 m

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

M8

M10 1/8"

M12 1/4"

M14

M16 3/8"

M18

M20 1/2"

10

12(13)

14

17

19

22

24

* Please contact COMECO! ** Available only for TSBL and TSBGL!

COMECO reserves the right of changing specifications without prior notice!

Probe design Temp. range


temperature probes

Ordering code

TSB(L,G,GL) - (MI -(1)) G2.G3.G4.G5'5".G6.G8.G9.G10.G11.G14.G15 - #1

Code Feature or option

Code values regular design

J - type "J", K - type "K", T - type "T"

G2

Thermocouple

G3

Temperature range

G4

Diameter 'd' [mm]

G5'

Bayonet size (2)

13 - ø13x1, 14 - ø14x1, 15 - ø15x1, 17 - ø17x1, 20 - ø20x1, Z - other (specify!)

G5"

Bayonet material (2)

AL - aluminum, BR - brass, SS - stainless steel

G6

Probe length 'n' [mm]

10…200

G8

Cable length 'k' [m] and type

1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (5), 1MF…10MF - mineral fiber, 1PV…10PV - PVC

G9

Mounting connection (3)

Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q7 - M12x1.5, Q8 - M14x1.5, Q10 - 1/2" NPT, Q18 - G1/8", Q19 - 1/8" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Q26 - M8x1, Q29 - M8x1.25, Q30 - M10x1.5, Uxx - union nut (xx - same as for Qxx)

G10

Sheath material (wetted parts)

G11

Accuracy class

1 - '1' (5), 2 - '2'

G14

Tip shape (hot junction)

X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design

G15

Connector

X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector

#1

Options

X - none, OV - vibration proof (MgO or Silicone filled) (4), OS - cable protection SS spring (≈ 50 mm) (1), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface (4)

MI design

E - type "E", N - type "N", T - type "T" T1 - -50…400 °C, T3 - 0…850 °C (5), T4 - 0…800 °C (5), T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C

regular design

4 (5), 5, 6, 8

MI design

4.5, 6, 8 (5)

regular design

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

MI design

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404

(1)

Available only for TSBL and TSBGL! Only for TSB and TSBL! Only for TSBG and TSBGL! (4) Only for non-MI (regular) design! (5) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

BAYONET CABLE INSERT

TSBS

Sheath - stainless steel (see table notes) Cable - see table notes

SENSITIVE ELEMENT

CABLE TYPE

TEMPERATURE RANGE

DIMENSIONS d [mm]

wires

RTD Design

1 x Pt (RB,RD,RF,RG)

SLSL, TSL

T9 T1*

GLGL, TT

T7 T8

-50...200 °C -50...400 °C

5

2, 3*

0...200 °C 0...400 °C

6, 7, 8

2, 3

5*, 6, 7, 8

2

Thermocouple Design SLSL, TSL

T9 T1*

GLGL, TT

T7 T8

1 x K, 1xJ

-50...200 °C -50...400 °C 0...200 °C 0...400 °C

Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9)

n = 5 … 25 mm

Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature)

k = 1 … 10 m

insert diameter 'd' [mm]

5

6

7

8

spring OD [mm]

5

6

7

8

Tip shape: - RTD: standard - T/C: standard (isolated) or grounded (see Appendix - Tip Shapes) Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors) Bayonet: - ø14x1; aluminum or Ni-plated brass (default) - ø12x1, ø15x1, ø18x1, or other on request * Please contact COMECO!

TSBS - G2.G3.G4.G5.G6.G8.G10.G11.G12.G14.G15 - #1

Code Feature or option G2

Code values

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, J - T/C type "J", K - T/C type "K"

G3

Temperature range

T7 - 0…200 °C, T9 - -50…200 °C, T8 - 0…400 °C, T1 - -50…400 °C

G4

Diameter 'd' [mm]

5, 6, 7, 8

G5

Bayonet

12 - ø12x1, 14 - ø14x1, 15 - ø15x1, 18 - ø18x1, Z - other (specify!) (3)

G6

Probe length 'n' [mm]

5…25

G8

Cable length 'k' [m] and type

G10

G11

Sheath material (wetted parts) Accuracy class (1)

1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®

RTD

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

T/C

M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

RTD

A - 'A', B - 'B', C - '2xB'

T/C

1 - '1' (3), 2 - '2' 2, 3 (3)

G12

Number of wires

G14

Tip shape (hot junction) (2)

X - standard (isolated from sheath), G - grounded

G15

Connector

X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector

#1

Options

X - none, OV - vibration proof (MgO or Silicone filled), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface

(1) (2) (3)

Only for RTD sensors! Only for thermocouples! Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code


temperature probes (MI) RTD PROBE FOR HEAD ASSEMBLY

TSECx

Sheath - stainless steel (see Appendix - Sheath materials) Extension wires - Teflon® or glass fiber

SENSITIVE ELEMENT

DIMENSIONS

TEMPERATURE RANGE

n [mm]

d [mm]

wires

Regular Design

DESIGN WITHOUT EXTENSION (TSEC) 1 x Pt (RB,RD,RF,RG)

2(3) x Pt (RB,RD,RF,RG)

-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C

1 x Cu (RH, RK)

T9

-50...200 °C

2 x Cu (RH, RK)

T9

-50...200 °C

T12

-50...100 °C

1 x PTC (RP, RQ)

EXTENDED DESIGN WITH MOVABLE CONNECTION (TSEC2)

DESIGN WITH ADJUSTABLE CONNECTION (TSEC3)

DESIGN WITH GLAND-TYPE CONNECTION (TSEC4)

2 x Pt (RB,RD,RF,RG)

T9 T1 T24 T11 T2 T4 T22

50…1500

-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C

2, 3* 2, 3, 4*

50…3000 8, 10, 12, 14, 16, 20

2, 3, 4

6*, 8, 10

2x2(3)*

12, 14, 16, 20

2x2(3), 3x2

50…3000 50…1500

6

2, 3, 4*

50…3000 8, 10, 12, 14, 16, 20 50…3000

50…1500 50…3000 50…3000 MI Design

2 x PTC (RP, RQ)

1 x Pt (RB,RD,RF,RG)

4 5 6

50…500

8, 10 12, 14, 16, 20 6 8, 10, 12, 14 8, 10, 12, 14

2x2 2x2(3)*

3*

2, 3*

2x2

4.5

2, 3*

6

2, 3, 4*

8

2, 3, 4

6, 8

2x2, 2x3*

50...50000

50...50000

2, 3

Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Head connection 'GH': - M10x1(Q20), M12x1.5(Q7), M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2) - 1/4"(Q23/Q24), 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11) - welding Extension length: m = 0…1500 mm (w/o spring-loaded adapter) m = m1...1500 mm (w/ spring-loaded adapter) Extension diameter: (for TSEC1 and TSEC2 only, [mm]) Probe diameter 'd' Ext. length 'm' up to 50 mm 50...150 mm 150...500 mm 500+ mm

3, 4 mm 8 8 10 14

4.5...6 mm d 8 10 14

8 mm d d 10 14

10 mm d d d 14

10+ mm d d d d

Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes) Process pressure: Probe design Max. pressure *

DESIGN WITH NIPPLE-UNION-NIPPLE CONNECTION (TSEC5)

TSEC, TSEC1 25 bar

TSEC4 6 bar

TSEC3, TSEC5 0 bar

Sheath material: 1.4301(M1), 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362(M15) Wire material: Cu, Ni, or Ag Extension wire isolation: Teflon® (T) or glass fiber (GL) Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Spring-loaded adapter: (mounted between probe and protection head)

m1

100...150

GH

20...25

* Please contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

TSEC2 16 bar

m1 = 60…100 mm d ≤ 8 mm

COMECO reserves the right of changing specifications without prior notice!

EXTENDED DESIGN WITH WELDED CONNECTION (TSEC1)

T9 T1 T24 T11 T2 T4 T22


temperature probes

Ordering code

TSEC(1,2,3,4,5) - (MI -) G1G2.G3.G4.G6.G7.G9'9".GH.G10.G11.G12.G13.G14 - #1

Code Feature or option

Code values

G1

Number of RTD sensors

1, 2, or 3 (10)

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP - PTC 1k, RQ - PTC 2k

G3

Temperature range

T1 - -50…400 °C, T2 - -200…600 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C, T22 - -200…200 °C, T24 - -50…500 °C

G4

Diameter 'd' [mm]

G6

Probe length 'n' [mm] (1)

50…50000 (see table overleaf)

G7

Probe length 'm' [mm] (2)

0…1500 (m1…1500 with 'OA' option)

G9'

Mounting connection

X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)

G9"

Compression fitting ferrule (4)

BR - brass, GR - graphite, SS - stainless steel, TF - Teflon®

GH

Head connection

W - welding, Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q6 - G3/4", Q7 - M12x1.5, Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Z - other connection (specify!)

G10

Sheath material (wetted parts)

G11

Accuracy class

X - none (5), A - 'A', B - 'B', C - '2xB'

G12

Number of wires

2, 3, 4 (10)

(6)

regular design

4, 5, 6, 8, 10, 12, 14, 16, 20

MI design

3 (10), 4.5, 6, 8

regular design MI design

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404), M15 - 1.4362 (10) M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404)

CU - copper (7), NI - nickel, AG - silver (8)

G13

Wire material

G14

Tip shape

X - standard closed, N - narrowed (8), P - pitted (8)

#1

Options

X - none, OV - vibration proof (MgO or Silicone filled) (8), OA - spring-loaded adapter (9), OP - electrochemically polished sheath surface (8)

(1)

'n+m' for TSEC3 and TSEC4! Only for TSEC1, TSEC2, and TSEC5! Only for TSEC! (4) Only for TSEC4! (5) For non-Pt sensors (6) Only for Pt sensors! (7) Not applicable to non-MI (regular) RTDs for above 500 °C! (8) Only for non-MI (regular) design! (9) Only for TSEC, TSEC1, and TSEC5! (10) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes (MI) T/C PROBE FOR HEAD ASSEMBLY

TSECx

Sheath - stainless steel (see Appendix - Sheath materials) Extension wires - Teflon® or glass fiber

SENSITIVE ELEMENT

TEMPERATURE RANGE

1(2) x J 1(2) x L

T4

0...800 °C

1(2) x K

T3 T16 T6*

0...850 °C 0...1100 °C 0...1150 °C

1(2) x E

T3 T13

1(2) x S 1(2) x R

DIMENSIONS n [mm]

d [mm]

wires

50...1500 50...3000

6 8, 10, 12, 14, 16, 20, 22

2 (2x2)

50...1500

6

50...3000

8, 10, 12, 14, 16, 20, 22

0...850 °C 0...1000 °C

50...1500 50...3000

6 8, 10, 12, 14, 16, 20, 22

2 (2x2)

T16 T6*

0...1100 °C 0...1150 °C

50...1500

6

50...3000

8, 10, 12, 14, 16, 20, 22

2 (2x2)

T4

0...800 °C

50...50000

3, 4.5, 6, 8, 10*

T8

0...400 °C

50...50000

3, 4.5, 6, 8, 10*

0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C

50...50000

3, 4.5, 6, 8, 10*

2

2xK 2 x N, 2 x E

T3 T16 T6* T6*

50...50000

3, 4.5, 6, 8, 10*

2x2

2xS 2xR

T16 T6*

0...1100 °C 0...1150 °C

50...10000

3, 4.5, 6

2x2

Regular Design

EXTENDED DESIGN WITH WELDED CONNECTION (TSEC1)

MI Design 1xJ 2xJ 1xT 2xT 1xK 1 x N, 1 x E

EXTENDED DESIGN WITH MOVABLE CONNECTION (TSEC2)

DESIGN WITH ADJUSTABLE CONNECTION (TSEC3)

DESIGN WITH GLAND-TYPE CONNECTION (TSEC4)

2 (2x2)

2 2x2 2 2x2

Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Head connection 'GH': - M10x1(Q20), M12x1.5(Q7), M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2) - 1/4"(Q23/Q24), 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11) - welding Extension length: m = 0…1500 mm (w/o spring-loaded adapter) m = m1...1500 mm (w/ spring-loaded adapter) Extension diameter: (for TSEC1 and TSEC2 only, [mm]) Probe diameter 'd' Ext. length 'm' up to 50 mm 50...150 mm 150...500 mm 500+ mm

3 mm

4.5, 6 mm

8 mm

10 mm

10+ mm

6 8 10 14

d 8 10 14

d d 10 14

d d d 14

d d d d

Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Process pressure: Probe design Max. pressure *

DESIGN WITH NIPPLE-UNION-NIPPLE CONNECTION (TSEC5)

TSEC, TSEC1 25 bar

TSEC4 6 bar

TSEC3, TSEC5 0 bar

Sheath material: 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362 (M15) MI sheath material: 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4876(M7), 2.4816(M8), Nicrobell® (M10) Extension wire isolation: Teflon® (T) or glass fiber (GL) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) Spring-loaded adapter: (mounted between probe and protection head)

m1

100...150

GH

20...25

* Please contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

TSEC2 16 bar

m1 = 60…100 mm d ≤ 8 mm

COMECO reserves the right of changing specifications without prior notice!

DESIGN WITHOUT EXTENSION (TSEC)


temperature probes

Ordering code

TSEC(1,2,3,4,5) - (MI -) G1G2.G3.G4.G6.G7.G9'9".GH.G10.G11.G14 - #1

Code Feature or option G1

Number of thermocouples

G2

Thermocouple

G3

Temperature range

G4

Diameter 'd' [mm]

Code values 1 or 2 regular design

E - type "E", J - type "J", K - type "K", L - type "L", R - type "R", S - type "S"

MI design

E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T" T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (7), T13 - 0…1000 °C, T16 - 0…1100 °C

regular design

6, 8, 10, 12, 14, 16, 20, 22

MI design

3, 4.5, 6, 8, 10

(1)

G6

Probe length 'n' [mm]

G7

Probe length 'm' [mm] (2)

0…1500 (m1…1500 with 'OA' option)

50…50000 (see table overleaf)

G9'

Mounting connection

X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)

G9"

Compression fitting ferrule (4)

BR - brass, GR - graphite, SS - stainless steel, TF - Teflon®

GH

Head connection

W - welding, Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q6 - G3/4", Q7 - M12x1.5, Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Z - other connection (specify!)

G10

Sheath material (wetted parts)

regular design

M2 - 1.4541, M3 - 1.4571, M4 - 1.4762, M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4401 (1.4404), M15 - 1.4362

MI design

M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4401 (1.4404), M10 - Nicrobell®

G11

Accuracy class

1 - '1' (7), 2 - '2'

G14

Tip shape (hot junction)

X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design

#1

Options

X - none, OA - spring-loaded adapter (5), OP - electrochemically polished sheath surface (6)

(1)

'n+m' for TSEC3 and TSEC4! Only for TSEC1, TSEC2, and TSEC5! Only for TSEC! (4) Only for TSEC4! (5) Only for TSEC, TSEC1, and TSEC5! (6) Only for non-MI (regular) design! (7) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

ANGLED PROBE WITH SCREW FIXING

TSG

Sheath - stainless steel (see table notes) Cable - see table notes

SENSITIVE ELEMENT 1 x Pt (RB,RD,RF,RG) 1 x K, 1 x J, 1xT

n = 10 ... 30 mm k = 1 ... 10 m

CABLE TYPE GLGL

TEMPERATURE RANGE T8 T7

0...400 °C 0...200 °C

SLSL, TSL

T9

-50...200 °C

TT

T7

YY, UU, YU

T10 T12

DIMENSIONS d [mm]

wires

4*, 5

2, 3*

6

2, 3

5, 6

2

0...200 °C -10...60 °C -50...100 °C

Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Tip shape: - RTD: standard - T/C: standard (isolated) or grounded (see Appendix - Tip Shapes)

8x8

10x10

Lmin

7

9

d

4, 5

4, 5, 6

Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors) * Please contact COMECO!

TSG - G2.G3.G4.G5.G6.G7.G8.G10.G11.G12.G14.G15 - #1

Code Feature or option G2

Code values

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, J - T/C type "J", K - T/C type "K", T - T/C type "T"

G3

Temperature range

T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T10 - -10…60 °C, T12 - -50…100 °C

G4

Diameter 'd' [mm]

4, 5, 6

G5

Dimension '□'

8 - 8x8 mm, 10 - 10x10 mm

G6

Probe length 'n' [mm]

10…30

G7

Dimension 'L' [mm]

7…20

G8

Cable length 'k' [m] and type

1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (3), 1PV…10PV - PVC

G10

Sheath material

G11 G12 G14

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

Accuracy class Number of wires

(1)

Tip shape (hot junction)

RTD

A - 'A', B - 'B', C - '2xB'

T/C

1 - '1' (3), 2 - '2' 2, 3

(2)

X - standard (isolated from sheath), G - grounded

G15

Connector

X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector

#1

Options

X - none, OV - vibration proof (MgO or Silicone filled), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface

(1)

Only for RTD sensors! Only for thermocouples! (3) Contact COMECO! (2)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code


temperature probes

PENETRATION RTD PROBE WITH HANDLE

TSIx

SENSITIVE ELEMENT

Sheath - stainless steel (see table notes) Cable and handle - see table notes DESIGN WITH SILICONE HANDLE (TSI1)

TEMPERATURE RANGE

1 x Pt (RB,RD,RF,RG)

T9

2 x Pt (RB,RD,RF,RG)

k = 1 … 10 m

T9

DIMENSIONS d [mm]

-50...200 °C

-50...200 °C

wires

4, 5

2, 3*

6

2, 3, 4*

8

2, 3, 4

5, 6

2x2

8

2, 3*

Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Cable type: - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature)

DESIGN WITH PLASTIC HANDLE (TSI2)

Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Handle type: - silicone (TSI1) - glass-filed plastic (TSI2) - stainless steel 1.4301 (TSI3)

k = 1 … 10 m

DESIGN WITH ROBUST METAL HANDLE (TSI3)

Filling: thermal conductive paste Cable connector: 4-pin (C3) (see Appendix - Connectors) Dimension limits: Model d=4

TSI1, TSI2 n = 50...200

TSI3 n = 50...200

d=5

n = 50...300

n = 50...300

d=6

n = 50...500

n = 50...500

d=8

-

n = 50...800

k = 1 … 10 m * Please contact COMECO!

Ordering code

TSI(1,2,3) - G1G2.G4.G6.G8.G10.G11.G12.G15 - #1 Code values

G1

Number of RTD sensors

1 or 2

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000

G4

Diameter 'd' [mm]

4, 5, 6, 8

G6

Probe length 'n' [mm]

50…500

G8

Cable length 'k' [m] and type

1SL…10SL - silicone, 1TF…10TF - Teflon® (1)

G10

Sheath material (wetted parts)

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

(1)

G11

Accuracy class

G12

Number of wires

G15

Connector

X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only)

#1

Options

X - none, OP - electrochemically polished sheath surface

(1)

A - 'A', B - 'B', C - '2xB' 2, 3 (1), 4 (1)

Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Code Feature or option


temperature probes

(MI) HAND-HELD PROBE WITH CONNECTOR

TSHx

DIMENSIONS SENSITIVE ELEMENT

Sheath - see table Cable - see table notes Connector - see table notes

SHEATH MATERIAL

TEMPERATURE RANGE

d [mm]

wires

RTD Design

DESIGN WITH PLASTIC HANDLE (TSH)

1 x Pt (RB,RD,RF,RG)

M1, M2, M3, M9

1 x Cu (RH, RK)

T7 T8 T1* T7

0...200 °C 0...400 °C -50...400 °C

4, 5

2, 3*

6

2, 3, 4*

0...200 °C

5*, 6

2, 3, 4*

5, 6

2

1, 1.5, 2, 3, 4.5, 6, 8, 10

2

1, 1.5, 2, 3, 4.5, 6, 8

2

Regular Thermocouple Design 1 x K, 1 x J,

M2, M3, M9

1xT n = 200 ... 2 000 mm

d ≤ 6 mm

T7

0...200 °C

T8

0...400 °C

MI Thermocouple Design

k = 1 … 10 m

M2, M3, M8 1 x J, 1 x T **

M9, M5

T4

0...800 °C

M4

DESIGN WITH ROBUST METAL HANDLE (TSHN)

M2, M3 T3

0...850 °C

M9 1 x K, 1 x N, n = 200 ... 2 000 mm

k = 1 … 10 m

6, 8

2

3, 4.5, 6

2

1, 1.5, 2, 3, 4.5, 6, 8, 10

2

1, 1.5, 2, 3, 4.5, 6, 8

2

M10

1 x E **

M7*

3, 6, 10

2

T16

0...1100 °C

1, 1.5, 2, 3, 4.5, 6, 8, 10

2

6, 8

2

T6

0...1150 °C

1.5, 3, 4.5, 6, 8

2

M10

T6

0...1250 °C

3, 4.5, 6

2

M8

T16

0...1100 °C

3, 4.5, 6

2

M8 M4 M5

1 x S(R)

Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4762 (M4), 1.4841 (M5), 1.4876 (M7), 2.4816 (M8), 1.4404 (M9), Nicrobell® (M10)

Tip shape: - RTD: standard, narrowed, pitted - T/C: standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors) * Please contact COMECO! ** For T/C type "T": (T8) 0...400 °C; for T/C type "E": (T13) 0...1000 °C

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature)


temperature probes

Ordering code

TSH(N) - (MI-) G2.G3.G4.G6.G8.G10.G11.G12.G14.G15 - #1

Code Feature or option G2

G3

G4

Code values regular design

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, J - T/C type "J", K - T/C type "K", T - T/C type "T"

MI design

E - T/C type "E", J - T/C type "J", K - T/C type "K", N - T/C type "N", R - T/C type "R", S - T/C type "S", T - T/C type "T"

Sensor

T1 - -50…400 °C, T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1150(1250) °C, T7 - 0…200 °C, T8 - 0…400 °C, T16 - 0…1100 °C

Temperature range

Diameter 'd' [mm]

RTD

4, 5, 6, 8

regular T/C design

5, 6

MI T/C design

1, 1.5, 2, 3, 4.5, 6, 8, 10

G6

Probe length 'n' [mm]

G8

Cable length 'k' [m] and type

G10

G11

Sheath material (wetted parts)

Accuracy class

200…2000 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®

RTD

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

regular T/C design

M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

MI T/C design

M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®

RTD

X - none (1), A - 'A', B - 'B', C - '2xB'

T/C

1 - '1' (5), 2 - '2'

(2)

2, 3, 4 (5)

G12

Number of wires

G14

Tip shape

G15

Connector

X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector

#1

Options

X - none, OV - vibration proof (MgO or Silicone filled) (4), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface (4)

RTD

X - standard closed, N - narrowed, P - pitted

T/C

X - standard (isolated from sheath) (3), G - grounded, E - exposed hot junction (3), O - open-tube design (3)

(1)

For non-Pt sensors Only for RTD sensors! (3) Not available when d = 1! (4) Only for non-MI (regular) design! (5) Contact COMECO!

COMECO reserves the right of changing specifications without prior notice!

(2)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

MAGNETIC PROBE FOR SURFACE MEASUREMENT

TSM

Design - pawn-type plastic body w/ permanent magnet ring Cable - see table notes

SENSITIVE ELEMENT 1 x Pt (RB,RD,RF,RG) 1 x K, 1xJ

CABLE TYPE

TEMPERATURE RANGE

WIRES

SLFSL, TFT

T7** T9**

0...200 °C -50...200 °C

2, 3*

YFY

T10 T12 T19

-10...60 °C -50...100 °C 0...100 °C

2

1xT

2

Sheath material: PPS plastic, magnet ring w/ ferrous metal jacket Cable type: - SLFSL or TFSL (silicone w/ copper shield, max. 250 °C ambient temperature) - TFT (Teflon® w/ copper shield, max. 250 °C ambient temperature) - YFY (PVC w/ copper shield, max. 105 °C ambient temperature) k = 1 ... 10 m Tip shape: - RTD: standard - T/C: grounded (see Appendix - Tip Shapes) Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors) * Please contact COMECO! ** Up to 250 °C (short-term)

TSM - G2.G3.G8.G11.G12.G15 - #1

Code Feature or option

Code values

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, J - T/C type "J", K - T/C type "K", T - T/C type "T"

G3

Temperature range

T7 - 0…200(250) °C, T9 - -50…200(250) °C, T10 - -10…60 °C, T12 - -50…100 °C, T19 - 0…100 °C

G8

Cable length 'k' [m] and type

G11

Accuracy class (1)

1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PV…10PV - PVC

RTD

A - 'A', B - 'B', C - '2xB'

T/C

1 - '1' (2), 2 - '2' 2, 3 (2)

G12

Number of wires

G15

Connector

X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector

#1

Options

X - none, OB - braid termination lead (only w/o connector)

(1) (2)

Only for RTD sensors! Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code


temperature probes

MAGNETIC THERMOCOUPLE PROBE FOR SURFACE MEASUREMENT

TSMS

Design - SS body w/ chromium plated magnet holder and T/C spring Extension cable - see table notes

SENSITIVE ELEMENT

CABLE TYPE

TEMPERATURE RANGE

WIRE [mm]

1 x K, 1 x J,

GLGLP, GLGLV

T8*

0...350 °C

0.5

1xN Sheath material: magnet holder: Cr-plated black steel sensor body: stainless steel w/ ceramic isolator

k = 1 ... 10 m

Cable type: GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) Tip shape: exposed hot junction, flat-surfaced (see Appendix - Tip Shapes) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) Thermocouple connector: 'standard' (C5) or 'miniature' (C6) (see Appendix - Connectors)

* up to 400 °C for short-term use

Ordering code

TSMS - G2.G8.G11.G15 - #1

Code Feature or option G2

Thermocouple

Code values J - type "J", K - type "K", N - type "N"

G8

Cable length 'k' [m] and type

1GL…10GL - glass fiber

G11

Accuracy class

1 - '1' (1), 2 - '2'

G15

Connector

X - none, C5 - T/C connector, C6 - miniature T/C connector

#1

Options

X - none, OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector)

Contact COMECO!

COMECO reserves the right of changing specifications without prior notice!

(1)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

MINERAL-INSULATED RTD PROBE

TSNx

Sheath - see table Extension cable - see table notes

MI CABLE PROBE ONLY (TSN)

SENSITIVE ELEMENT

SHEATH TEMPERATURE MATERIAL RANGE **

1 x Pt (RB,RD,RF,RG)

M1, M2, M3, M5, M8, M9

2 x Pt (RB,RD,RF,RG)

M1, M2, M3, M5, M8, M9

d

n

T7 T8 T9 T22 T1 T11 T4

0...200 °C 0...400 °C -50...200 °C -200...200 °C -50...400 °C -50...600 °C 0...800 °C

DIMENSIONS d [mm]

wires

3*, 4.5, 6, 8

2, 3, 4*

4.5*, 6, 8

2x2 2x3*

n = 50 ... 50 000 mm Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4841 (M5), 2.4816 (M8), 1.4404 (M9)

DESIGN WITH EXTENSION CABLE (TSNA)

Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature ***) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature ***) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Tip shape: standard or narrowed * (see Appendix - Tip Shapes)

n = 50 ... 50 000 mm k = 1 … 10 m

d D

3 6

4.5 6

6 8

8 d

Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Cable connector: 4-pin (C3) (see Appendix - Connectors)

DESIGN WITH CONNECTOR (TSNH)

Temperature limitation: The temperature around TSNA holding tube and TSNH(A) connector must not exceed -50...200 °C!

n = 50 ... 50 000 mm

DESIGN WITH CONNECTOR AND EXTENSION CABLE (TSNHA)

n

k

~ 60

d

* Please contact COMECO! n = 50 ... 50 000 mm

d ≤ 6 mm

k = 1 … 10 m

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

** Max. 550 °C (for chip RTD) or 800 °C (for wire-wound RTD) *** Sub-zero temperatures are not recommended

COMECO reserves the right of changing specifications without prior notice!

d ≤ 6 mm


temperature probes

Ordering code

TSN(A,H,HA) - G1G2.G3.G4.G6.G8.G10.G11.G12.G14.G15 - #1

Code Feature or option

Code values

G1

Number of RTD sensors

1 or 2

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000

G3

Temperature range

T7 - 0…200 °C, T9 - -50…200 °C, T22 - 200…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T11 - 50…600 °C (4), T4 - 0…800 °C (4)

G4

Diameter 'd' [mm] (1)

3 (4), 4.5, 6, 8

G6

Probe length 'n' [mm]

50…50000

G8

Cable length 'k' [m] and type

X - no cable, 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1PV…10PV - PVC

G10

Sheath material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404

G11

Accuracy class

A - 'A', B - 'B', C - '2xB'

G12

Number of wires

2, 3, 4 (4)

G14

Tip shape

X - standard (isolated from sheath), N - narrowed (2,4)

G15

Connector

#1

Options

(3)

X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only) X - none, OS - cable protection SS spring (≈ 50 mm) (3), OB - braid termination lead (only w/o connector) (3)

(1)

Up to 6 mm for TSNH and TSNHA Only for TSN! Only for TSNA and TSNHA! (4) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

MINERAL-INSULATED THERMOCOUPLE PROBE

TSNx SENSITIVE ELEMENT

Sheath - see table Extension cable - see table notes

SHEATH MATERIAL M1

1 x J,

MI CABLE PROBE ONLY (TSN)

1 x T **

TEMPERATURE RANGE max. 400 °C

M2,M3,M9,M5,M8 M4

d [mm] 1, 1.5, 2, 3, 4.5, 6, 8, 10*

max. 800 °C

6, 8

M10 2xJ 2 x T **

n = 50 ... 50 000 mm 1 x K, 1 x N, 1 x E **

DESIGN WITH EXTENSION CABLE (TSNA)

M1 M2,M3,M9,M5,M8 M4 M2, M3, M9

max. 850 °C

M8 M4

2xK

M7*

2xN

M8 M4 M5

n = 50 ... 50 000 mm k = 1 … 10 m

d D

<6 6

6 8

8, 10 d

DESIGN WITH CONNECTOR (TSNH)

6, 8 1, 1.5, 2, 3, 4.5, 6, 8, 10*

M7*

M2, M3, M9

2 x S(R)

1.5, 2, 3, 4.5, 6, 8, 10*

max. 800 °C max. 400 °C

M10

1 x S(R),

max. 400 °C

M1

M5

2 x E **

3, 4.5, 6

M8

3, 6, 10* max. 1100 °C

max. 1150 °C

1, 1.5, 2, 3, 4.5, 6, 8, 10* 6, 8 1.5, 3, 4.5, 6, 8

max. 1250 °C

3, 4.5, 6

max. 850 °C

1.5, 3, 4.5, 6, 8

max. 1100 °C max. 1150 °C

3, 6, 10* 1.5, 3, 4.5, 6, 8 6, 8 1.5, 3, 4.5, 6, 8

max. 1100 °C

3, 4.5, 6

Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4762 (M4), 1.4841 (M5), 1.4876 (M7), 2.4816 (M8), 1.4404 (M9), Nicrobell® (M10) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes)

n = 50 ... 50 000 mm

DESIGN WITH CONNECTOR AND EXTENSION CABLE (TSNHA)

Thermocouple connector: 'standard' (C5) or 'miniature' (C6) (see Appendix - Connectors) Temperature limitation: The temperature around TSNA holding tube and TSNH(A) connector must not exceed -50...200 °C!

n = 50 ... 50 000 mm

d ≤ 6 mm

k = 1 … 10 m

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

* Please contact COMECO! ** For T/C type "T": max. 400 °C; for T/C type "E": max. 1000 °C

COMECO reserves the right of changing specifications without prior notice!

Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)

d ≤ 6 mm


temperature probes

Ordering code

TSN(A,H,HA) - G1G2.G3.G4.G6.G8.G10.G11.G14.G15 - #1

Code Feature or option

Code values

G1

Number of thermocouples

1 or 2 (1)

G2

Thermocouple

E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T"

G3

Temperature range

T7 - 0…200 °C, T9 - -50…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T4 - 0…800 °C, T3 - 0…850 °C, T16 - 0…1100 °C, T6 - 0…1150(1250) °C

G4

Diameter 'd' [mm] (2)

1 (3), 1.5 (4), 2, 3, 4.5, 6, 8, 10

G6

Probe length 'n' [mm]

50…50000

G8

Cable length 'k' [m] and type

X - no cable, 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®

G10

Sheath material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®

G11

Accuracy class

1 - '1' (6), 2 - '2'

G14

Tip shape (hot junction)

X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design

G15

Connector (5)

X - none, C5 - T/C connector, C6 - miniature T/C connector

#1

Options

X - none, OS - cable protection SS spring (≈ 50 mm) (5), OB - braid termination lead (only w/o connector) (5)

(1)

Only for TSN. Ask for TSNA! Up to 6 mm for TSNH and TSNHA Always grounded (4) Grounded when G1="2" (5) Only for TSNA and TSNHA! (6) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

MINERAL-INSULATED RTD PROBE

TSNx

Sheath - see table Extension cable - see table notes

MI CABLE PROBE ONLY (TSN)

SENSITIVE ELEMENT

SHEATH TEMPERATURE MATERIAL RANGE **

1 x Pt (RB,RD,RF,RG)

M1, M2, M3, M5, M8, M9

2 x Pt (RB,RD,RF,RG)

M1, M2, M3, M5, M8, M9

d

n

T7 T8 T9 T22 T1 T11 T4

0...200 °C 0...400 °C -50...200 °C -200...200 °C -50...400 °C -50...600 °C 0...800 °C

DIMENSIONS d [mm]

wires

3*, 4.5, 6, 8

2, 3, 4*

4.5*, 6, 8

2x2 2x3*

n = 50 ... 50 000 mm Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4841 (M5), 2.4816 (M8), 1.4404 (M9)

DESIGN WITH EXTENSION CABLE (TSNA)

Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature ***) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature ***) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Tip shape: standard or narrowed * (see Appendix - Tip Shapes)

n = 50 ... 50 000 mm k = 1 … 10 m

d D

3 6

4.5 6

6 8

8 d

Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Cable connector: 4-pin (C3) (see Appendix - Connectors)

DESIGN WITH CONNECTOR (TSNH)

Temperature limitation: The temperature around TSNA holding tube and TSNH(A) connector must not exceed -50...200 °C!

n = 50 ... 50 000 mm

DESIGN WITH CONNECTOR AND EXTENSION CABLE (TSNHA)

n

k

~ 60

d

* Please contact COMECO! n = 50 ... 50 000 mm

d ≤ 6 mm

k = 1 … 10 m

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

** Max. 550 °C (for chip RTD) or 800 °C (for wire-wound RTD) *** Sub-zero temperatures are not recommended

COMECO reserves the right of changing specifications without prior notice!

d ≤ 6 mm


temperature probes

Ordering code

TSN(A,H,HA) - G1G2.G3.G4.G6.G8.G10.G11.G12.G14.G15 - #1

Code Feature or option

Code values

G1

Number of RTD sensors

1 or 2

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000

G3

Temperature range

T7 - 0…200 °C, T9 - -50…200 °C, T22 - 200…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T11 - 50…600 °C (4), T4 - 0…800 °C (4)

G4

Diameter 'd' [mm] (1)

3 (4), 4.5, 6, 8

G6

Probe length 'n' [mm]

50…50000

G8

Cable length 'k' [m] and type

X - no cable, 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1PV…10PV - PVC

G10

Sheath material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404

G11

Accuracy class

A - 'A', B - 'B', C - '2xB'

G12

Number of wires

2, 3, 4 (4)

G14

Tip shape

X - standard (isolated from sheath), N - narrowed (2,4)

G15

Connector

#1

Options

(3)

X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only) X - none, OS - cable protection SS spring (≈ 50 mm) (3), OB - braid termination lead (only w/o connector) (3)

(1)

Up to 6 mm for TSNH and TSNHA Only for TSN! Only for TSNA and TSNHA! (4) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

MINERAL-INSULATED THERMOCOUPLE PROBE

TSNx SENSITIVE ELEMENT

Sheath - see table Extension cable - see table notes

SHEATH MATERIAL M1

1 x J,

MI CABLE PROBE ONLY (TSN)

1 x T **

TEMPERATURE RANGE max. 400 °C

M2,M3,M9,M5,M8 M4

d [mm] 1, 1.5, 2, 3, 4.5, 6, 8, 10*

max. 800 °C

6, 8

M10 2xJ 2 x T **

n = 50 ... 50 000 mm 1 x K, 1 x N, 1 x E **

DESIGN WITH EXTENSION CABLE (TSNA)

M1 M2,M3,M9,M5,M8 M4 M2, M3, M9

max. 850 °C

M8 M4

2xK

M7*

2xN

M8 M4 M5

n = 50 ... 50 000 mm k = 1 … 10 m

d D

<6 6

6 8

8, 10 d

DESIGN WITH CONNECTOR (TSNH)

6, 8 1, 1.5, 2, 3, 4.5, 6, 8, 10*

M7*

M2, M3, M9

2 x S(R)

1.5, 2, 3, 4.5, 6, 8, 10*

max. 800 °C max. 400 °C

M10

1 x S(R),

max. 400 °C

M1

M5

2 x E **

3, 4.5, 6

M8

3, 6, 10* max. 1100 °C

max. 1150 °C

1, 1.5, 2, 3, 4.5, 6, 8, 10* 6, 8 1.5, 3, 4.5, 6, 8

max. 1250 °C

3, 4.5, 6

max. 850 °C

1.5, 3, 4.5, 6, 8

max. 1100 °C max. 1150 °C

3, 6, 10* 1.5, 3, 4.5, 6, 8 6, 8 1.5, 3, 4.5, 6, 8

max. 1100 °C

3, 4.5, 6

Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4762 (M4), 1.4841 (M5), 1.4876 (M7), 2.4816 (M8), 1.4404 (M9), Nicrobell® (M10) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes)

n = 50 ... 50 000 mm

DESIGN WITH CONNECTOR AND EXTENSION CABLE (TSNHA)

Thermocouple connector: 'standard' (C5) or 'miniature' (C6) (see Appendix - Connectors) Temperature limitation: The temperature around TSNA holding tube and TSNH(A) connector must not exceed -50...200 °C!

n = 50 ... 50 000 mm

d ≤ 6 mm

k = 1 … 10 m

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

* Please contact COMECO! ** For T/C type "T": max. 400 °C; for T/C type "E": max. 1000 °C

COMECO reserves the right of changing specifications without prior notice!

Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)

d ≤ 6 mm


temperature probes

Ordering code

TSN(A,H,HA) - G1G2.G3.G4.G6.G8.G10.G11.G14.G15 - #1

Code Feature or option

Code values

G1

Number of thermocouples

1 or 2 (1)

G2

Thermocouple

E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T"

G3

Temperature range

T7 - 0…200 °C, T9 - -50…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T4 - 0…800 °C, T3 - 0…850 °C, T16 - 0…1100 °C, T6 - 0…1150(1250) °C

G4

Diameter 'd' [mm] (2)

1 (3), 1.5 (4), 2, 3, 4.5, 6, 8, 10

G6

Probe length 'n' [mm]

50…50000

G8

Cable length 'k' [m] and type

X - no cable, 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®

G10

Sheath material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®

G11

Accuracy class

1 - '1' (6), 2 - '2'

G14

Tip shape (hot junction)

X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design

G15

Connector (5)

X - none, C5 - T/C connector, C6 - miniature T/C connector

#1

Options

X - none, OS - cable protection SS spring (≈ 50 mm) (5), OB - braid termination lead (only w/o connector) (5)

(1)

Only for TSN. Ask for TSNA! Up to 6 mm for TSNH and TSNHA Always grounded (4) Grounded when G1="2" (5) Only for TSNA and TSNHA! (6) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

MINERAL-INSULATED RTD PROBE

TSNx

Sheath - see table Extension cable - see table notes

MI CABLE PROBE ONLY (TSN)

SENSITIVE ELEMENT

SHEATH TEMPERATURE MATERIAL RANGE **

1 x Pt (RB,RD,RF,RG)

M1, M2, M3, M5, M8, M9

2 x Pt (RB,RD,RF,RG)

M1, M2, M3, M5, M8, M9

d

n

T7 T8 T9 T22 T1 T11 T4

0...200 °C 0...400 °C -50...200 °C -200...200 °C -50...400 °C -50...600 °C 0...800 °C

DIMENSIONS d [mm]

wires

3*, 4.5, 6, 8

2, 3, 4*

4.5*, 6, 8

2x2 2x3*

n = 50 ... 50 000 mm Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4841 (M5), 2.4816 (M8), 1.4404 (M9)

DESIGN WITH EXTENSION CABLE (TSNA)

Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature ***) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature ***) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Tip shape: standard or narrowed * (see Appendix - Tip Shapes)

n = 50 ... 50 000 mm k = 1 … 10 m

d D

3 6

4.5 6

6 8

8 d

Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Cable connector: 4-pin (C3) (see Appendix - Connectors)

DESIGN WITH CONNECTOR (TSNH)

Temperature limitation: The temperature around TSNA holding tube and TSNH(A) connector must not exceed -50...200 °C!

n = 50 ... 50 000 mm

DESIGN WITH CONNECTOR AND EXTENSION CABLE (TSNHA)

n

k

~ 60

d

* Please contact COMECO! n = 50 ... 50 000 mm

d ≤ 6 mm

k = 1 … 10 m

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

** Max. 550 °C (for chip RTD) or 800 °C (for wire-wound RTD) *** Sub-zero temperatures are not recommended

COMECO reserves the right of changing specifications without prior notice!

d ≤ 6 mm


temperature probes

Ordering code

TSN(A,H,HA) - G1G2.G3.G4.G6.G8.G10.G11.G12.G14.G15 - #1

Code Feature or option

Code values

G1

Number of RTD sensors

1 or 2

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000

G3

Temperature range

T7 - 0…200 °C, T9 - -50…200 °C, T22 - 200…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T11 - 50…600 °C (4), T4 - 0…800 °C (4)

G4

Diameter 'd' [mm] (1)

3 (4), 4.5, 6, 8

G6

Probe length 'n' [mm]

50…50000

G8

Cable length 'k' [m] and type

X - no cable, 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1PV…10PV - PVC

G10

Sheath material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404

G11

Accuracy class

A - 'A', B - 'B', C - '2xB'

G12

Number of wires

2, 3, 4 (4)

G14

Tip shape

X - standard (isolated from sheath), N - narrowed (2,4)

G15

Connector

#1

Options

(3)

X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only) X - none, OS - cable protection SS spring (≈ 50 mm) (3), OB - braid termination lead (only w/o connector) (3)

(1)

Up to 6 mm for TSNH and TSNHA Only for TSN! Only for TSNA and TSNHA! (4) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

MINERAL-INSULATED THERMOCOUPLE PROBE

TSNx SENSITIVE ELEMENT

Sheath - see table Extension cable - see table notes

SHEATH MATERIAL M1

1 x J,

MI CABLE PROBE ONLY (TSN)

1 x T **

TEMPERATURE RANGE max. 400 °C

M2,M3,M9,M5,M8 M4

d [mm] 1, 1.5, 2, 3, 4.5, 6, 8, 10*

max. 800 °C

6, 8

M10 2xJ 2 x T **

n = 50 ... 50 000 mm 1 x K, 1 x N, 1 x E **

DESIGN WITH EXTENSION CABLE (TSNA)

M1 M2,M3,M9,M5,M8 M4 M2, M3, M9

max. 850 °C

M8 M4

2xK

M7*

2xN

M8 M4 M5

n = 50 ... 50 000 mm k = 1 … 10 m

d D

<6 6

6 8

8, 10 d

DESIGN WITH CONNECTOR (TSNH)

6, 8 1, 1.5, 2, 3, 4.5, 6, 8, 10*

M7*

M2, M3, M9

2 x S(R)

1.5, 2, 3, 4.5, 6, 8, 10*

max. 800 °C max. 400 °C

M10

1 x S(R),

max. 400 °C

M1

M5

2 x E **

3, 4.5, 6

M8

3, 6, 10* max. 1100 °C

max. 1150 °C

1, 1.5, 2, 3, 4.5, 6, 8, 10* 6, 8 1.5, 3, 4.5, 6, 8

max. 1250 °C

3, 4.5, 6

max. 850 °C

1.5, 3, 4.5, 6, 8

max. 1100 °C max. 1150 °C

3, 6, 10* 1.5, 3, 4.5, 6, 8 6, 8 1.5, 3, 4.5, 6, 8

max. 1100 °C

3, 4.5, 6

Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4762 (M4), 1.4841 (M5), 1.4876 (M7), 2.4816 (M8), 1.4404 (M9), Nicrobell® (M10) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes)

n = 50 ... 50 000 mm

DESIGN WITH CONNECTOR AND EXTENSION CABLE (TSNHA)

Thermocouple connector: 'standard' (C5) or 'miniature' (C6) (see Appendix - Connectors) Temperature limitation: The temperature around TSNA holding tube and TSNH(A) connector must not exceed -50...200 °C!

n = 50 ... 50 000 mm

d ≤ 6 mm

k = 1 … 10 m

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

* Please contact COMECO! ** For T/C type "T": max. 400 °C; for T/C type "E": max. 1000 °C

COMECO reserves the right of changing specifications without prior notice!

Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)

d ≤ 6 mm


temperature probes

Ordering code

TSN(A,H,HA) - G1G2.G3.G4.G6.G8.G10.G11.G14.G15 - #1

Code Feature or option

Code values

G1

Number of thermocouples

1 or 2 (1)

G2

Thermocouple

E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T"

G3

Temperature range

T7 - 0…200 °C, T9 - -50…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T4 - 0…800 °C, T3 - 0…850 °C, T16 - 0…1100 °C, T6 - 0…1150(1250) °C

G4

Diameter 'd' [mm] (2)

1 (3), 1.5 (4), 2, 3, 4.5, 6, 8, 10

G6

Probe length 'n' [mm]

50…50000

G8

Cable length 'k' [m] and type

X - no cable, 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®

G10

Sheath material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®

G11

Accuracy class

1 - '1' (6), 2 - '2'

G14

Tip shape (hot junction)

X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design

G15

Connector

(5)

#1

Options

X - none, C5 - T/C connector, C6 - miniature T/C connector X - none, OS - cable protection SS spring (≈ 50 mm) (5), OB - braid termination lead (only w/o connector) (5)

(1)

Only for TSN. Ask for TSNA! Up to 6 mm for TSNH and TSNHA (3) Always grounded (4) Grounded when G1="2" (5) Only for TSNA and TSNHA! (6) Contact COMECO!

COMECO reserves the right of changing specifications without prior notice!

(2)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

MINERAL-INSULATED RTD PROBE

TSNx

Sheath - see table Extension cable - see table notes

MI CABLE PROBE ONLY (TSN)

SENSITIVE ELEMENT

SHEATH TEMPERATURE MATERIAL RANGE **

1 x Pt (RB,RD,RF,RG)

M1, M2, M3, M5, M8, M9

2 x Pt (RB,RD,RF,RG)

M1, M2, M3, M5, M8, M9

d

n

T7 T8 T9 T22 T1 T11 T4

0...200 °C 0...400 °C -50...200 °C -200...200 °C -50...400 °C -50...600 °C 0...800 °C

DIMENSIONS d [mm]

wires

3*, 4.5, 6, 8

2, 3, 4*

4.5*, 6, 8

2x2 2x3*

n = 50 ... 50 000 mm Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4841 (M5), 2.4816 (M8), 1.4404 (M9)

DESIGN WITH EXTENSION CABLE (TSNA)

Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature ***) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature ***) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Tip shape: standard or narrowed * (see Appendix - Tip Shapes)

n = 50 ... 50 000 mm k = 1 … 10 m

d D

3 6

4.5 6

6 8

8 d

Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Cable connector: 4-pin (C3) (see Appendix - Connectors)

DESIGN WITH CONNECTOR (TSNH)

Temperature limitation: The temperature around TSNA holding tube and TSNH(A) connector must not exceed -50...200 °C!

n = 50 ... 50 000 mm

DESIGN WITH CONNECTOR AND EXTENSION CABLE (TSNHA)

n

k

~ 60

d

* Please contact COMECO! n = 50 ... 50 000 mm

d ≤ 6 mm

k = 1 … 10 m

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

** Max. 550 °C (for chip RTD) or 800 °C (for wire-wound RTD) *** Sub-zero temperatures are not recommended

COMECO reserves the right of changing specifications without prior notice!

d ≤ 6 mm


temperature probes

Ordering code

TSN(A,H,HA) - G1G2.G3.G4.G6.G8.G10.G11.G12.G14.G15 - #1

Code Feature or option

Code values

G1

Number of RTD sensors

1 or 2

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000

G3

Temperature range

T7 - 0…200 °C, T9 - -50…200 °C, T22 - 200…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T11 - 50…600 °C (4), T4 - 0…800 °C (4)

G4

Diameter 'd' [mm] (1)

3 (4), 4.5, 6, 8

G6

Probe length 'n' [mm]

50…50000

G8

Cable length 'k' [m] and type

X - no cable, 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1PV…10PV - PVC

G10

Sheath material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404

G11

Accuracy class

A - 'A', B - 'B', C - '2xB'

G12

Number of wires

2, 3, 4 (4)

G14

Tip shape

X - standard (isolated from sheath), N - narrowed (2,4)

G15

Connector

#1

Options

(3)

X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only) X - none, OS - cable protection SS spring (≈ 50 mm) (3), OB - braid termination lead (only w/o connector) (3)

(1)

Up to 6 mm for TSNH and TSNHA Only for TSN! Only for TSNA and TSNHA! (4) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

MINERAL-INSULATED THERMOCOUPLE PROBE

TSNx SENSITIVE ELEMENT

Sheath - see table Extension cable - see table notes

SHEATH MATERIAL M1

1 x J,

MI CABLE PROBE ONLY (TSN)

1 x T **

TEMPERATURE RANGE max. 400 °C

M2,M3,M9,M5,M8 M4

d [mm] 1, 1.5, 2, 3, 4.5, 6, 8, 10*

max. 800 °C

6, 8

M10 2xJ 2 x T **

n = 50 ... 50 000 mm 1 x K, 1 x N, 1 x E **

DESIGN WITH EXTENSION CABLE (TSNA)

M1 M2,M3,M9,M5,M8 M4 M2, M3, M9

max. 850 °C

M8 M4

2xK

M7*

2xN

M8 M4 M5

n = 50 ... 50 000 mm k = 1 … 10 m

d D

<6 6

6 8

8, 10 d

DESIGN WITH CONNECTOR (TSNH)

6, 8 1, 1.5, 2, 3, 4.5, 6, 8, 10*

M7*

M2, M3, M9

2 x S(R)

1.5, 2, 3, 4.5, 6, 8, 10*

max. 800 °C max. 400 °C

M10

1 x S(R),

max. 400 °C

M1

M5

2 x E **

3, 4.5, 6

M8

3, 6, 10* max. 1100 °C

max. 1150 °C

1, 1.5, 2, 3, 4.5, 6, 8, 10* 6, 8 1.5, 3, 4.5, 6, 8

max. 1250 °C

3, 4.5, 6

max. 850 °C

1.5, 3, 4.5, 6, 8

max. 1100 °C max. 1150 °C

3, 6, 10* 1.5, 3, 4.5, 6, 8 6, 8 1.5, 3, 4.5, 6, 8

max. 1100 °C

3, 4.5, 6

Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4762 (M4), 1.4841 (M5), 1.4876 (M7), 2.4816 (M8), 1.4404 (M9), Nicrobell® (M10) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes)

n = 50 ... 50 000 mm

DESIGN WITH CONNECTOR AND EXTENSION CABLE (TSNHA)

Thermocouple connector: 'standard' (C5) or 'miniature' (C6) (see Appendix - Connectors) Temperature limitation: The temperature around TSNA holding tube and TSNH(A) connector must not exceed -50...200 °C!

n = 50 ... 50 000 mm

d ≤ 6 mm

k = 1 … 10 m

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

* Please contact COMECO! ** For T/C type "T": max. 400 °C; for T/C type "E": max. 1000 °C

COMECO reserves the right of changing specifications without prior notice!

Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)

d ≤ 6 mm


temperature probes

Ordering code

TSN(A,H,HA) - G1G2.G3.G4.G6.G8.G10.G11.G14.G15 - #1

Code Feature or option

Code values

G1

Number of thermocouples

1 or 2 (1)

G2

Thermocouple

E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T"

G3

Temperature range

T7 - 0…200 °C, T9 - -50…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T4 - 0…800 °C, T3 - 0…850 °C, T16 - 0…1100 °C, T6 - 0…1150(1250) °C

G4

Diameter 'd' [mm] (2)

1 (3), 1.5 (4), 2, 3, 4.5, 6, 8, 10

G6

Probe length 'n' [mm]

50…50000

G8

Cable length 'k' [m] and type

X - no cable, 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®

G10

Sheath material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®

G11

Accuracy class

1 - '1' (6), 2 - '2'

G14

Tip shape (hot junction)

X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design

G15

Connector (5)

X - none, C5 - T/C connector, C6 - miniature T/C connector

#1

Options

X - none, OS - cable protection SS spring (≈ 50 mm) (5), OB - braid termination lead (only w/o connector) (5)

(1)

Only for TSN. Ask for TSNA! Up to 6 mm for TSNH and TSNHA Always grounded (4) Grounded when G1="2" (5) Only for TSNA and TSNHA! (6) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

SCREW-IN MI RTD PROBE

TSNGx

Sheath - see table Extension cable - see table notes

STRAIGHT DESIGN (TSNG)

n = 50 ... 50 000 mm k = 1 … 10 m

EXTENDED DESIGN (TSNG1)

SENSITIVE ELEMENT

SHEATH TEMPERATURE MATERIAL RANGE **

1 x Pt (RB,RD,RF,RG)

M1, M2, M3, M5, M8, M9

2 x Pt (RB,RD,RF,RG)

M1, M2, M3, M5, M8, M9

T7 T8 T9 T22 T1 T11 T4

0...200 °C 0...400 °C -50...200 °C -200...200 °C -50...400 °C -50...600 °C 0...800 °C

DIMENSIONS d [mm]

wires

3*, 4.5, 6, 8

2, 3, 4*

2x2

4.5*, 6, 8

2x3*

Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4841 (M5), 2.4816 (M8), 1.4404 (M9) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature ***) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature ***) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Tip shape: standard (see Appendix - Tip Shapes)

n = 50 ... 50 000 mm m = 60 ... 50 000 mm k = 1 … 10 m

Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Cable connector: 4-pin (C3) (see Appendix - Connectors) Temperature limitation: The temperature beyond the HEX body (SW) must not exceed -50...200 °C!

ANGLED DESIGN (TSNGL)

Available threads and HEX sizes:

SW

M6

M8

10

10

M10 1/8" 12(13)

M12 1/4" 14

M14 17

M16 3/8" 19

M18 22

* Please contact COMECO! n = 50 ... 50 000 mm k = 1 … 10 m

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

** Max. 550 °C (for chip RTD) or 800 °C (for wire-wound RTD) *** Sub-zero temperatures are not recommended

M20 1/2" 24

COMECO reserves the right of changing specifications without prior notice!

G


temperature probes

Ordering code

TSNG(G1,L) - G1G2.G3.G4.G6.G7.G8.G9.G10.G11.G12.G15 - #1

Code Feature or option

Code values

G1

Number of RTD sensors

1 or 2

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000

G3

Temperature range

T7 - 0…200 °C, T9 - -50…200 °C, T22 - 200…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T11 - 50…600 °C (3), T4 - 0…800 °C (3)

G4

Diameter 'd' [mm]

3 (3), 4.5, 6, 8

G6

Probe length 'n' [mm]

50…50000

G7

Probe length 'm' [mm] (1)

60…50000

G8

Cable length 'k' [m] and type

1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (3), 1PV…10PV - PVC

G9

Mounting connection

Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q7 - M12x1.5, Q8 - M14x1.5, Q10 - 1/2" NPT, Q18 - G1/8", Q19 - 1/8" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Q26 - M8x1, Q29 - M8x1.25, Q30 - M10x1.5, Q31 - M6x1, Uxx - union nut (xx - same as for Qxx)

G10

Sheath material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404

G11

Accuracy class

A - 'A', B - 'B', C - '2xB'

G12

Number of wires

2, 3, 4 (3)

G15

Connector

X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only)

#1

Options

X - none, OS - cable protection SS spring (≈ 50 mm) (2), OB - braid termination lead (only w/o connector)

(1)

Only for TSNG1! Only for TSNG! (3) Contact COMECO!

COMECO reserves the right of changing specifications without prior notice!

(2)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

SCREW-IN MI THERMOCOUPLE PROBE

TSNGx

Sheath - see table Extension cable - see table notes

SENSITIVE ELEMENT

SHEATH MATERIAL

TEMPERATURE RANGE max. 400 °C

M1

STRAIGHT DESIGN (TSNG)

1 x J,

M2,M3,M9,M5,M8

1 x T **

M4

d [mm] 1.5, 2, 3, 4.5, 6, 8, 10*

max. 800 °C

6, 8

M10 max. 400 °C

M1

2xJ

M2,M3,M9,M5,M8

2 x T **

n = 50 ... 50 000 mm k = 1 … 10 m

3, 4.5, 6

max. 800 °C

M4 M1

max. 400 °C

M2, M3, M9

max. 850 °C

6, 8 1.5, 2, 3, 4.5, 6, 8, 10*

M7*

1 x K, 1 x N,

3, 6, 10* max. 1100 °C

M8

1 x E **

M4

EXTENDED DESIGN (TSNG1)

max. 1150 °C

M5 M10 2xK

M7*

2xN

M8

2 x E **

M4

1 x S(R),

3, 4.5, 6 1.5, 3, 4.5, 6, 8

max. 1150 °C

3, 6, 10* 1.5, 3, 4.5, 6, 8 6, 8 1.5, 3, 4.5, 6, 8

max. 1100 °C

M8

2 x S(R)

6, 8 1.5, 3, 4.5, 6, 8

max. 850 °C max. 1100 °C

M5

1.5, 2, 3, 4.5, 6, 8, 10*

max. 1250 °C

M2, M3, M9

n = 50 ... 50 000 mm m = 60 ... 50 000 mm k = 1 … 10 m

1.5, 2, 3, 4.5, 6, 8, 10*

3, 4.5, 6

Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4762 (M4), 1.4841 (M5), 1.4876 (M7), 2.4816 (M8), 1.4404 (M9), Nicrobell® (M10) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature)

ANGLED DESIGN (TSNGL)

Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes)

n = 50 ... 50 000 mm k = 1 … 10 m

Thermocouple connector: 'standard' (C5) or 'miniature' (C6) (see Appendix - Connectors) Temperature limitation: The temperature beyond the HEX body (SW) must not exceed -50...200 °C! Available threads and HEX sizes: G SW

M6

M8

10

10

M10 1/8" 12(13)

M12 1/4" 14

M14 17

M16 3/8" 19

M18 22

M20 1/2" 24

* Please contact COMECO! ** For T/C type "T": max. 400 °C; for T/C type "E": max. 1000 °C

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)


temperature probes

Ordering code

TSNG(G1,L) - G1G2.G3.G4.G6.G7.G8.G9.G10.G11.G14.G15 - #1

Code Feature or option

Code values

G1

Number of thermocouples

1 or 2

G2

Thermocouple

E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T"

G3

Temperature range

T7 - 0…200 °C, T9 - -50…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T4 - 0…800 °C, T3 - 0…850 °C, T16 - 0…1100 °C, T6 - 0…1150(1250) °C

G4

Diameter 'd' [mm]

1.5 (1), 2, 3, 4.5, 6, 8

G6

Probe length 'n' [mm]

50…50000

G7

Probe length 'm' [mm] (2)

60…50000

G8

Cable length 'k' [m] and type

1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®

G9

Mounting connection

Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q7 - M12x1.5, Q8 - M14x1.5, Q10 - 1/2" NPT, Q18 - G1/8", Q19 - 1/8" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Q26 - M8x1, Q29 - M8x1.25, Q30 - M10x1.5, Q31 - M6x1, Uxx - union nut (xx - same as for Qxx)

G10

Sheath material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®

G11

Accuracy class

1 - '1' (4), 2 - '2'

G14

Tip shape (hot junction)

X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design

G15

Connector

X - none, C5 - T/C connector, C6 - miniature T/C connector

#1

Options

X - none, OS - cable protection SS spring (≈ 50 mm) (3), OB - braid termination lead (only w/o connector)

(1)

Grounded when G1="2" Only for TSNG1! (3) Only for TSNG! (4) Contact COMECO!

COMECO reserves the right of changing specifications without prior notice!

(2)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

(MI**) CLAMP CABLE PROBE FOR PIPE-SURFACE MEASUREMENT

TSTx

DIMENSIONS SENSITIVE ELEMENT

Sheath - stainless steel (see table notes) Clamp - see table notes Cable - see table notes

CABLE TYPE

TEMPERATURE RANGE

d [mm]

wires

RTD Design

STRAIGHT-TUBE DESIGN (TST)

4.5**, 5

2, 3*

6

2, 3, 4*

T7 T8

0...200 °C 0...400 °C

6

2x2

SLSL, TSL, YY, UU, YU

T9

-50...200 °C

GLGL, TT

T7

0...200 °C

SLSL, TSL, YY, UU, YU

T12

-50...100 °C

GLGL, TT

T19

0...100 °C

SLSL, TSL, YY, UU, YU

T9 T1*

2 x Pt (RB,RD,RF,RG)

GLGL, TT

1 x Cu (RH, RK) 2 x Cu (RH, RK) n = 20 … 100 mm D = 17 … 280 mm k = 1 … 10 m

-50...200 °C -50...400 °C

1 x Pt (RB,RD,RF,RG)

1 x PTC (RP, RQ)

5*

2, 3*

6

2, 3, 4*

6

2x2

6

2, 3

5, 6

2

4.5, 6

2

Regular Thermocouple Design

DESIGN WITH ANGLED TERMINATION (TSTL)

1 x J, 1 x K, 1xT

SLSL, TSL, YY, UU, YU

T9 T1*

GLGL, TT

T8

-50...200 °C -50...400 °C 0...400 °C

MI Thermocouple Design ** 1 x N, 1 x E, 1xT

SLSL, TSL, YY, UU, YU

T9 T1*

GLGL, TT

T8

-50...200 °C -50...400 °C 0...400 °C

Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature)

Diameter 'D'

Average pipe OD

17...29 mm

22

25...45 mm

35

40...60 mm 63...83 mm

50 73

Tip shape: - RTD: standard - T/C: standard (isolated) or grounded (see Appendix - Tip Shapes) Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance)

78...98 mm

88

93...113 mm

103

108...128 mm

118

123...143 mm

133

138...158 mm 153...173 mm

148 163

168...188 mm

178

17...113 mm

8 mm or 14 mm

183...203 mm

193

108...280 mm

14 mm

198...218 mm

208

213...233 mm 228...248 mm

223 238

243...263 mm

253

258...280 mm

269

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors) Available clamp sizes: Diameter 'D'

Clamp width

- other on request

* Please contact COMECO! ** Available only for TSTL!

COMECO reserves the right of changing specifications without prior notice!

n = 20 … 100 mm D = 17 … 280 mm k = 1 … 10 m


temperature probes

Ordering code

TST(L) - (MI -(1)) G1G2.G3.G4.G5.G6.G8.G10.G11.G12.G14.G15 - #1

Code Feature or option G1 G2

G3 G4

Code values

Number of sensors (3)

1 or 2 regular design

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP -PTC 1k, RQ - PTC 2k, J - T/C type "J", K - T/C type "K", T - T/C type "T"

MI design

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP -PTC 1k, RQ - PTC 2k, E - T/C type "E", N - T/C type "N", T - T/C type "T"

Sensor

T1 - -50…400 °C, T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T12 - 50…100 °C, T19 - 0…100 °C

Temperature range regular design

Diameter 'd' [mm]

MI design

5, 6 4.5, 6

G5

Clamp diameter 'D' (average pipe OD)

22 - 17…29 mm, 35 - 25…45 mm, 50 - 40…60 mm, 73 - 63…83 mm, 88 - 78…98 mm, 103 - 93…113 mm, 118 - 108…128 mm, 133 - 123…143 mm, 148 - 138…158 mm, 163 - 153…173 mm, 178 - 168…188 mm, 193 - 183…203 mm, 208 - 198…218 mm, 223 - 213…233 mm, 238 - 228…248 mm, 253 - 243…263 mm, 269 - 258…280 mm, Z - other on request (specify average pipe OD) (6)

G6

Probe length 'n' [mm]

20…100

G8

Cable length 'k' [m] and type

1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (6), 1PV…10PV - PVC

G10

Sheath material (wetted parts)

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

G11

Accuracy class

G12

Number of wires (3)

RTD

X - none (2), A - 'A', B - 'B', C - '2xB'

T/C

1 - '1' (6), 2 - '2' 2, 3, 4 (6)

(4)

G14

Tip shape (hot junction)

X - standard (isolated from sheath), G - grounded

G15

Connector

X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector

#1

Options

X - none, OV - vibration proof (MgO or Silicone filled) (5), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface (5)

(1)

Available only for TSTL! For non-Pt sensors Only for RTD sensors! (4) Only for thermocouples! (5) Only for non-MI (regular) design! (6) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

TOROIDAL CABLE PROBE

TSTO SENSITIVE ELEMENT

Sheath - stainless steel (see table notes) Cable - see table notes

CABLE TYPE

TEMPERATURE RANGE

DIMENSIONS d [mm]

wires

RTD Design -50...200 °C -50...100 °C

4, 5

2, 3*

6

2, 3, 4*

0...200 °C 0...400 °C

6

2x2

6

2, 3

5, 6

2

1 x Pt (RB,RD,RF,RG)

SLSL, TSL, YY, UU, YU

T9 T12

2 x Pt (RB,RD,RF,RG)

GLGL, TT

T7 T8

SLSL, TSL, YY, UU, YU

T12

-50...100 °C

GLGL, TT

T19

0...100 °C

1 x PTC (RP, RQ)

Thermocouple Design SLSL, TSL, YY, UU, YU

T9

-50...200 °C

1 x J, 1xT

GLGL, TT

T8

0...400 °C

1 x K,

n = 20 … 30 mm D = 8 … 24 mm k = 1 … 10 m

Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9)

d [mm]

4

5

6

H [mm]

6

7

8

Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) Tip shape: - RTD: standard - T/C: standard (isolated) or grounded (see Appendix - Tip Shapes) Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors)

COMECO reserves the right of changing specifications without prior notice!

* Please contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

Ordering code

TSTO - G1G2.G3.G4.G5.G6.G8.G10.G11.G12.G14.G15 - #1

Code Feature or option

Code values

G1

Number of sensors

1 or 2

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RP -PTC 1k, RQ - PTC 2k, J - T/C type "J", K - T/C type "K", T - T/C type "T"

G3

Temperature range

T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T12 - 50…100 °C, T19 - 0…100 °C

G4

Diameter 'd' [mm]

4, 5, 6

G5

Toroid diameter 'D' [mm]

8…24

G6

Probe length 'n' [mm]

20…30

G8

Cable length 'k' [m] and type

1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1PV…10PV - PVC

G10

Sheath material (wetted parts)

G11

Accuracy class (2)

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

RTD

X - none (1), A - 'A', B - 'B', C - '2xB'

T/C

1 - '1' (4), 2 - '2' 2, 3, 4 (4)

G12

Number of wires

G14

Tip shape (hot junction) (3)

X - standard (isolated from sheath), G - grounded

G15

Connector

X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector

#1

Options

X - none, OV - vibration proof (MgO or Silicone filled), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface

(1)

For non-Pt sensors Only for RTD sensors! Only for thermocouples! (4) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

FINGER CABLE PROBE FOR PIPE-SURFACE MEASUREMENT

TSY SENSITIVE ELEMENT

Sheath - stainless steel (see table notes) Cable - see table notes

CABLE TYPE

TEMPERATURE RANGE

WIRES

RTD Design -50...200 °C -50...100 °C

2, 3, 4*

0...200 °C 0...400 °C

2x2

1 x Pt (RB,RD,RF,RG)

SLSL, TSL, YY, UU, YU

T9 T12

2 x Pt (RB,RD,RF,RG)

GLGL, TT

T7 T8

SLSL, TSL, YY, UU, YU

T12

-50...100 °C

GLGL, TT

T19

0...100 °C

1 x PTC (RP, RQ)

2, 3

Thermocouple Design SLSL, TSL, YY, UU, YU

T9

-50...200 °C

1 x J, 1xT

GLGL, TT

T8

0...400 °C

1 x K,

2

Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) n = 20 … 30 mm k = 1 … 10 m

Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Tip shape: - RTD: standard - T/C: standard (isolated) or grounded (see Appendix - Tip Shapes) Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors) * Please contact COMECO!

TSY - G1G2.G3.G6.G8.G10.G11.G12.G14.G15 - #1

Code Feature or option

Code values

G1

Number of sensors

1 or 2

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RP -PTC 1k, RQ - PTC 2k, J - T/C type "J", K - T/C type "K", T - T/C type "T"

G3

Temperature range

T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T12 - 50…100 °C, T19 - 0…100 °C

G6

Probe length 'n' [mm]

20…30

G8

Cable length 'k' [m] and type

1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1PV…10PV - PVC

G10

Sheath material (wetted parts)

G11

Accuracy class (2)

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

RTD

X - none (1), A - 'A', B - 'B', C - '2xB'

T/C

1 - '1' (4), 2 - '2' 2, 3, 4 (4)

G12

Number of wires

G14

Tip shape (hot junction) (3)

X - standard (isolated from sheath), G - grounded

G15

Connector

X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector

#1

Options

X - none, OV - vibration proof (MgO or Silicone filled), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface

(1)

For non-Pt sensors Only for RTD sensors! Only for thermocouples! (4) Contact COMECO! (2) (3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code


temperature probes

(MI) RTD REPLACEABLE INSERT - PREPARED FOR IN-HEAD TRANSMITTER ** Sheath - stainless steel (see Appendix - Sheath materials) Terminal base - Al2O3. Terminals - Ni-plated brass

TSSx TSOSx

DIMENSIONS SENSITIVE ELEMENT

TEMPERATURE RANGE

n [mm]

d [mm]

wires

Regular Design

DESIGN WITH TERMINAL BLOCK TYPE "M" (TS(O)SM) 1 x Pt (RB,RD,RF,RG)

2 x Pt (RB,RD,RF,RG) 3 x Pt * (RB,RD,RF,RG) 1 x Cu (RH, RK) 2 x Cu (RH, RK) 1 x PTC (RP, RQ)

T9 T1 T24 T11 T2 T4 T22 T9

-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C -50...200 °C

T9

-50...200 °C

T12

-50...100 °C

50…200

4

2

50…500

5

2, 3*

50…1500

6

2, 3, 4*

50…3000

8

2, 3, 4

50…3000

6, 8, 10

2x2, 2x3*

50…3000

8, 10

3x2

50…1500

6

2, 3, 4*

8

2, 3, 4

50…3000 50…3000

2 x PTC (RP, RQ)

6

2x2*

8

2x2(3)*

50…1500

6

50…3000

8, 10

50…3000

8, 10

2, 3 2x2

MI Design 1 x Pt (RB,RD,RF,RG)

DESIGN WITH TERMINAL BLOCK TYPE "B" (TS(O)SB) 2 x Pt (RB,RD,RF,RG)

T9 T1 T24 T11 T2 T4 T22

-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C

50...50000

50...50000

3*

2, 3*

4.5

2, 3*

6

2, 3, 4*

8

2, 3, 4

6, 8

2x2, 2x3*

Suitable protection heads: (see Appendix - Protection Heads) - TS(O)SM: heads with 20 mm mounting distance - TS(O)SB: heads with 33 mm mounting distance Fixing to protection head: direct (default) or springing ('OS' option) Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes) Sheath material: 1.4301(M1), 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362 (M15)

Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance)

* Please contact COMECO! ** No transmitter mounted!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Wire material: Cu, Ni, or Ag


temperature probes

Ordering code

TS (B, M) - (MI -) G1G2.G3.G4.G6.G10.G11.G12.G13.G14 - #1

Code Feature or option

Code values

Base model variant

S - standard (w/ terminal block), OS - prepared for in-head transmitter (w/o terminal block)

G1

Number of RTD sensors

1, 2, or 3 (7)

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP - PTC 1k, RQ - PTC 2k

G3

Temperature range

T1 - -50…400 °C, T2 - -200…600 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C, T22 - -200…200 °C, T24 - -50…500 °C

G4

Diameter 'd' [mm]

G6

Insert length 'n' [mm]

regular design

4, 5, 6, 8, 10

MI design

3 (7), 4.5, 6, 8

(1)

50…50000 (see table overleaf) regular design

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404, M15 - 1.4362

G10

Sheath material (wetted parts)

G11

Accuracy class

X - none (2), A - 'A', B - 'B', C - '2xB'

G12

Number of wires

2, 3, 4 (7)

(3)

MI design

M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

CU - copper (4), NI - nickel, AG - silver (5)

G13

Wire material

G14

Tip shape

X - standard closed, N - narrowed (5), P - pitted (5)

#1

Options

X - none, OV - vibration proof (MgO or Silicone filled) (5,6), OS - spring-fixed terminal block, OP - electrochemically polished sheath surface (5)

(1)

This length does not coincide with the probe immersion length! For non-Pt sensors Only for Pt sensors! (4) Not applicable to non-MI (regular) RTDs for above 500 °C! (5) Only for non-MI (regular) design! (6) Requires 'OS' option! (7) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

(MI) T/C REPLACEABLE INSERT - PREPARED FOR IN-HEAD TRANSMITTER ** Sheath - stainless steel (see Appendix - Sheath materials) Terminal base - Al2O3. Terminals - Ni-plated brass

TSSx TSOSx

DIMENSIONS SENSITIVE ELEMENT

TEMPERATURE RANGE

n [mm]

d [mm]

wires

Regular Design

DESIGN WITH TERMINAL BLOCK TYPE "M" (TS(O)SM)

50...1500

6

50...3000

8, 10

50...1500

6

50...3000

8, 10

1(2) x J 1(2) x L

T4

0...800 °C

1(2) x K

T3 T16 T6*

0...850 °C 0...1100 °C 0...1150 °C

1(2) x E

T3 T13

0...850 °C 0...1000 °C

50...1500

6

50...3000

8, 10

1(2) x S 1(2) x R

T16 T6*

0...1100 °C 0...1150 °C

50...1500

6

50...3000

8, 10

2 (2x2) 2 (2x2) 2 (2x2) 2 (2x2)

MI Design 1xJ

0...800 °C

50...50000

3, 4.5, 6, 8

T8

0...400 °C

50...50000

3, 4.5, 6, 8

0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C

50...50000

3, 4.5, 6, 8

2

2xK 2 x N, 2 x E

T3 T16 T6* T6*

50...50000

3, 4.5, 6, 8

2x2

2xS 2xR

T16 T6*

0...1100 °C 0...1150 °C

50...10000

3, 4.5, 6

2x2

1xT 2xT 1xK 1 x N, 1 x E

DESIGN WITH TERMINAL BLOCK TYPE "B" (TS(O)SB)

2

T4

2xJ

2x2 2 2x2

Suitable protection heads: (see Appendix - Protection Heads) - TS(O)SM: heads with 20 mm mounting distance - TS(O)SB: heads with 33 mm mounting distance Fixing to protection head: direct (default) or springing ('OS' option) Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Sheath material: 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362 (M15)

Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)

* Please contact COMECO! ** No transmitter mounted!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

MI sheath material: 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4876(M7), 2.4816(M8), Nicrobell® (M10)


temperature probes

Ordering code

TS (B, M) - (MI -) G1G2.G3.G4.G6.G10.G11.G14 - #1

Code Feature or option

Code values

Base model variant

S - standard (w/ terminal block), OS - prepared for in-head transmitter (w/o terminal block)

G1

Number of thermocouples

1 or 2

G2

Thermocouple

G3

Temperature range

G4

Diameter 'd' [mm]

G6

Insert length 'n' [mm] (1)

G10

Sheath material (wetted parts)

regular design

E - type "E", J - type "J", K - type "K", L - type "L", R - type "R", S - type "S"

MI design

E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T" T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (4), T13 - 0…1000 °C, T16 - 0…1100 °C

regular design

6, 8, 10

MI design

3, 4.5, 6, 8

regular design

M2 - 1.4541, M3 - 1.4571, M4 - 1.4762, M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4404, M15 - 1.4362

MI design

M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®

50…50000 (see table overleaf)

G11

Accuracy class

1 - '1' (4), 2 - '2'

G14

Tip shape (hot junction)

X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design

#1

Options

X - none, OV - vibration proof (secured screws) (2,3), OS - spring-fixed terminal block, OP - electrochemically polished sheath surface (2)

(1)

This length does not coincide with the probe immersion length! Only for non-MI (regular) design! Requires 'OS' option! (4) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

(MI) RTD REPLACEABLE INSERT - PREPARED FOR IN-HEAD TRANSMITTER ** Sheath - stainless steel (see Appendix - Sheath materials) Terminal base - Al2O3. Terminals - Ni-plated brass

TSSx TSOSx

DIMENSIONS SENSITIVE ELEMENT

TEMPERATURE RANGE

n [mm]

d [mm]

wires

Regular Design

DESIGN WITH TERMINAL BLOCK TYPE "M" (TS(O)SM) 1 x Pt (RB,RD,RF,RG)

2 x Pt (RB,RD,RF,RG) 3 x Pt * (RB,RD,RF,RG) 1 x Cu (RH, RK) 2 x Cu (RH, RK) 1 x PTC (RP, RQ)

T9 T1 T24 T11 T2 T4 T22 T9

-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C -50...200 °C

T9

-50...200 °C

T12

-50...100 °C

50…200

4

2

50…500

5

2, 3*

50…1500

6

2, 3, 4*

50…3000

8

2, 3, 4

50…3000

6, 8, 10

2x2, 2x3*

50…3000

8, 10

3x2

50…1500

6

2, 3, 4*

8

2, 3, 4

50…3000 50…3000

2 x PTC (RP, RQ)

6

2x2*

8

2x2(3)*

50…1500

6

50…3000

8, 10

50…3000

8, 10

2, 3 2x2

MI Design 1 x Pt (RB,RD,RF,RG)

DESIGN WITH TERMINAL BLOCK TYPE "B" (TS(O)SB) 2 x Pt (RB,RD,RF,RG)

T9 T1 T24 T11 T2 T4 T22

-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C

50...50000

50...50000

3*

2, 3*

4.5

2, 3*

6

2, 3, 4*

8

2, 3, 4

6, 8

2x2, 2x3*

Suitable protection heads: (see Appendix - Protection Heads) - TS(O)SM: heads with 20 mm mounting distance - TS(O)SB: heads with 33 mm mounting distance Fixing to protection head: direct (default) or springing ('OS' option) Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes) Sheath material: 1.4301(M1), 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362 (M15)

Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance)

* Please contact COMECO! ** No transmitter mounted!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Wire material: Cu, Ni, or Ag


temperature probes

Ordering code

TS (B, M) - (MI -) G1G2.G3.G4.G6.G10.G11.G12.G13.G14 - #1

Code Feature or option

Code values

Base model variant

S - standard (w/ terminal block), OS - prepared for in-head transmitter (w/o terminal block)

G1

Number of RTD sensors

1, 2, or 3 (7)

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP - PTC 1k, RQ - PTC 2k

G3

Temperature range

T1 - -50…400 °C, T2 - -200…600 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C, T22 - -200…200 °C, T24 - -50…500 °C

G4

Diameter 'd' [mm]

G6

Insert length 'n' [mm]

regular design

4, 5, 6, 8, 10

MI design

3 (7), 4.5, 6, 8

(1)

50…50000 (see table overleaf) regular design

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404, M15 - 1.4362

G10

Sheath material (wetted parts)

G11

Accuracy class

X - none (2), A - 'A', B - 'B', C - '2xB'

G12

Number of wires

2, 3, 4 (7)

(3)

MI design

M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

CU - copper (4), NI - nickel, AG - silver (5)

G13

Wire material

G14

Tip shape

X - standard closed, N - narrowed (5), P - pitted (5)

#1

Options

X - none, OV - vibration proof (MgO or Silicone filled) (5,6), OS - spring-fixed terminal block, OP - electrochemically polished sheath surface (5)

(1)

This length does not coincide with the probe immersion length! For non-Pt sensors Only for Pt sensors! (4) Not applicable to non-MI (regular) RTDs for above 500 °C! (5) Only for non-MI (regular) design! (6) Requires 'OS' option! (7) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

(MI) T/C REPLACEABLE INSERT - PREPARED FOR IN-HEAD TRANSMITTER ** Sheath - stainless steel (see Appendix - Sheath materials) Terminal base - Al2O3. Terminals - Ni-plated brass

TSSx TSOSx

DIMENSIONS SENSITIVE ELEMENT

TEMPERATURE RANGE

n [mm]

d [mm]

wires

Regular Design

DESIGN WITH TERMINAL BLOCK TYPE "M" (TS(O)SM)

50...1500

6

50...3000

8, 10

50...1500

6

50...3000

8, 10

1(2) x J 1(2) x L

T4

0...800 °C

1(2) x K

T3 T16 T6*

0...850 °C 0...1100 °C 0...1150 °C

1(2) x E

T3 T13

0...850 °C 0...1000 °C

50...1500

6

50...3000

8, 10

1(2) x S 1(2) x R

T16 T6*

0...1100 °C 0...1150 °C

50...1500

6

50...3000

8, 10

2 (2x2) 2 (2x2) 2 (2x2) 2 (2x2)

MI Design 1xJ

0...800 °C

50...50000

3, 4.5, 6, 8

T8

0...400 °C

50...50000

3, 4.5, 6, 8

0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C

50...50000

3, 4.5, 6, 8

2

2xK 2 x N, 2 x E

T3 T16 T6* T6*

50...50000

3, 4.5, 6, 8

2x2

2xS 2xR

T16 T6*

0...1100 °C 0...1150 °C

50...10000

3, 4.5, 6

2x2

1xT 2xT 1xK 1 x N, 1 x E

DESIGN WITH TERMINAL BLOCK TYPE "B" (TS(O)SB)

2

T4

2xJ

2x2 2 2x2

Suitable protection heads: (see Appendix - Protection Heads) - TS(O)SM: heads with 20 mm mounting distance - TS(O)SB: heads with 33 mm mounting distance Fixing to protection head: direct (default) or springing ('OS' option) Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Sheath material: 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362 (M15)

Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)

* Please contact COMECO! ** No transmitter mounted!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

MI sheath material: 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4876(M7), 2.4816(M8), Nicrobell® (M10)


temperature probes

Ordering code

TS (B, M) - (MI -) G1G2.G3.G4.G6.G10.G11.G14 - #1

Code Feature or option

Code values

Base model variant

S - standard (w/ terminal block), OS - prepared for in-head transmitter (w/o terminal block)

G1

Number of thermocouples

1 or 2

G2

Thermocouple

G3

Temperature range

G4

Diameter 'd' [mm]

G6

Insert length 'n' [mm] (1)

G10

Sheath material (wetted parts)

regular design

E - type "E", J - type "J", K - type "K", L - type "L", R - type "R", S - type "S"

MI design

E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T" T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (4), T13 - 0…1000 °C, T16 - 0…1100 °C

regular design

6, 8, 10

MI design

3, 4.5, 6, 8

regular design

M2 - 1.4541, M3 - 1.4571, M4 - 1.4762, M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4404, M15 - 1.4362

MI design

M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®

50…50000 (see table overleaf)

G11

Accuracy class

1 - '1' (4), 2 - '2'

G14

Tip shape (hot junction)

X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design

#1

Options

X - none, OV - vibration proof (secured screws) (2,3), OS - spring-fixed terminal block, OP - electrochemically polished sheath surface (2)

(1)

This length does not coincide with the probe immersion length! Only for non-MI (regular) design! Requires 'OS' option! (4) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes (MI) RTD PROBE WITH PROTECTION HEAD

TSCx

- FOR IN-HEAD TRANSMITTER ** TSOCx Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum, stainless steel, iron, or plastic (see Appendix - Protection heads)

DIMENSIONS SENSITIVE ELEMENT

TEMPERATURE RANGE

n [mm]

d [mm]

wires

Regular Design

DESIGN WITHOUT EXTENSION (TS(O)C)

1 x Pt (RB,RD,RF,RG)

2(3) x Pt (RB,RD,RF,RG)

-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C

1 x Cu (RH, RK)

T9

-50...200 °C

2 x Cu (RH, RK)

T9

-50...200 °C

T12

-50...100 °C

1 x PTC (RP, RQ)

EXTENDED DESIGN WITH WELDED CONNECTION (TS(O)C1)

T9 T1 T24 T11 T2 T4 T22

2 x Pt (RB,RD,RF,RG)

T9 T1 T24 T11 T2 T4 T22

50…1500

-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C

2, 3* 2, 3, 4*

50…3000 8, 10, 12, 14, 16, 20

2, 3, 4

6*, 8, 10

2x2(3)*

12, 14, 16, 20

2x2(3), 3x2

50…3000 50…1500

6

2, 3, 4*

50…3000 8, 10, 12, 14, 16, 20 50…3000

50…1500 50…3000 50…3000 MI Design

2 x PTC (RP, RQ)

1 x Pt (RB,RD,RF,RG)

4 5 6

50…500

8, 10 12, 14, 16, 20 6 8, 10, 12, 14 8, 10, 12, 14

2x2 2x2(3)*

3*

2, 3*

50...50000

50...50000

2, 3 2x2

4.5

2, 3*

6

2, 3, 4*

8

2, 3, 4

6, 8

2x2, 2x3*

Protection head: B, MA, MB, G, N, Cx, Dx, Ex (see Appendix - Protection Heads)

EXTENDED DESIGN WITH MOVABLE CONNECTION (TS(O)C2)

Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Thermal isolation between nipple and metal head: (for TS(O)C only) Protection head MA, MB B other

Maximum temperature 200 °C 400 °C

Insulation material POM Teflon®

Extension length: m = 0…1500 mm Extension diameter: (for TS(O)C1 and TS(O)C2 only, [mm]) Probe diameter 'd' Ext. length 'm' up to 50 mm 50...150 mm 150...500 mm 500+ mm

3, 4 mm

4.5...6 mm

8 mm

10 mm

10+ mm

8 8 10 14

d 8 10 14

d d 10 14

d d d 14

d d d d

Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes) Process pressure:

DESIGN WITH GLAND-TYPE CONNECTION (TS(O)C4)

Probe design Max. pressure *

TS(O)C, TS(O)C1 25 bar

TS(O)C2 16 bar

TS(O)C4 6 bar

TS(O)C3 0 bar

Sheath material: 1.4301(M1), 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362(M15) Wire material: Cu, Ni, or Ag Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) * Please contact COMECO! ** Order transmitter separately!!!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

DESIGN WITH ADJUSTABLE CONNECTION (TS(O)C3)

Length 'n' up to 50 mm up to 100 mm up to 150 mm


temperature probes

Ordering code

TS (1,2,3,4) - (MI -) G0.G1G2.G3.G4.G6.G7.G9'9".G10.G11.G12.G13.G14 - #1.#2

Code Feature or option

Code values

Base model variant

C - standard (w/ terminal block), OC - prepared for in-head transmitter (w/o terminal block)

G0

Protection head

B - type "B", CC - type "CC", CS - type "CS", D - type "D", DH - type "DH", DHW - type "DHW", DW - type "DW", E - type "E", EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", ES - type "ES", G - type "G", MA - type "MA", MB - type "MB", N - type "N"

G1

Number of RTD sensors

1, 2, or 3 (11)

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP - PTC 1k, RQ - PTC 2k

G3

Temperature range

T1 - -50…400 °C, T2 - -200…600 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C, T22 - -200…200 °C, T24 - -50…500 °C

G4

Diameter 'd' [mm]

regular design

4, 5, 6, 8, 10, 12, 14, 16, 20

MI design

3 (11), 4.5, 6, 8

(1)

G6

Probe length 'n' [mm]

G7

Probe length 'm' [mm] (2)

0…1500

50…50000 (see table overleaf)

G9'

Mounting connection

X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)

G9"

Compression fitting ferrule (4)

BR - brass, GR - graphite, SS - stainless steel, TF - Teflon®

regular design

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404), M15 - 1.4362 (11)

MI design

M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404)

G10

Sheath material (wetted parts)

G11

Accuracy class

X - none (5), A - 'A', B - 'B', C - '2xB'

G12

Number of wires

2, 3, 4 (11)

(6)

CU - copper (7), NI - nickel, AG - silver (8)

G13

Wire material

G14

Tip shape

X - standard closed, N - narrowed (8), P - pitted (8)

#1

Options

X - none, OV - vibration proof (spring terminals, MgO or Silicone filled, secured screws) (8), OT - thermal isolation (3), OP - electrochemically polished sheath surface (8)

#2

Incorporated devices

X - none, T - in-head transmitter (9), A - local indicator (10)

(1)

'n+m' for TS(O)C3 and TS(O)C4! Only for TS(O)C1 and TS(O)C2! Only for TS(O)C! (4) Only for TS(O)C4! (5) For non-Pt sensors (6) Only for Pt sensors! (7) Not applicable to non-MI (regular) RTDs for above 500 °C! (8) Only for non-MI (regular) design! (9) Only for variant 'OC'! See transmitter datasheets and order separately! (10) With windowed head only! See indicator datasheets and order separately! (11) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes (MI) T/C PROBE WITH PROTECTION HEAD

TSCx

- FOR IN-HEAD TRANSMITTER ** TSOCx Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum, stainless steel, iron, or plastic (see Appendix - Protection heads)

DIMENSIONS SENSITIVE ELEMENT

TEMPERATURE RANGE

n [mm]

d [mm]

wires

50...1500 50...3000

6 8, 10, 12, 14, 16, 20, 22

2 (2x2)

50...1500

6

50...3000

8, 10, 12, 14, 16, 20, 22

Regular Design

DESIGN WITHOUT EXTENSION (TS(O)C)

1(2) x J 1(2) x L

T4

0...800 °C

1(2) x K

T3 T16 T6*

0...850 °C 0...1100 °C 0...1150 °C

1(2) x E

T3 T13

0...850 °C 0...1000 °C

50...1500

6

50...3000

8, 10, 12, 14, 16, 20, 22

1(2) x S 1(2) x R

T16 T6*

0...1100 °C 0...1150 °C

50...1500

6

50...3000

8, 10, 12, 14, 16, 20, 22

2 (2x2) 2 (2x2) 2 (2x2)

MI Design

EXTENDED DESIGN WITH WELDED CONNECTION (TS(O)C1)

1xJ 2xJ 1xT 2xT

2 2x2 2 2x2

T4

0...800 °C

50...50000

3, 4.5, 6, 8, 10*

T8

0...400 °C

50...50000

3, 4.5, 6, 8, 10*

0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C

50...50000

3, 4.5, 6, 8, 10*

2

2xK 2 x N, 2 x E

T3 T16 T6* T6*

50...50000

3, 4.5, 6, 8, 10*

2x2

2xS 2xR

T16 T6*

0...1100 °C 0...1150 °C

50...10000

3, 4.5, 6

2x2

1xK 1 x N, 1 x E

Protection head: B, MA, MB, G, N, Cx, Dx, Ex (see Appendix - Protection Heads)

EXTENDED DESIGN WITH MOVABLE CONNECTION (TS(O)C2)

Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Thermal isolation between nipple and metal head: (for TS(O)C only) Protection head MA, MB B other

Length 'n' up to 50 mm up to 100 mm up to 150 mm

Maximum temperature 200 °C 400 °C

Insulation material POM Teflon®

Extension length: m = 0…1500 mm Extension diameter: (for TS(O)C1 and TS(O)C2 only, [mm]) Probe diameter 'd' Ext. length 'm' up to 50 mm 50...150 mm 150...500 mm 500+ mm

3 mm

4.5, 6 mm

8 mm

10 mm

10+ mm

6 8 10 14

d 8 10 14

d d 10 14

d d d 14

d d d d

Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Process pressure: Probe design Max. pressure *

DESIGN WITH GLAND-TYPE CONNECTION (TS(O)C4)

TS(O)C, TS(O)C1 25 bar

TS(O)C2 16 bar

TS(O)C4 6 bar

TS(O)C3 0 bar

Sheath material: 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362 (M15) MI sheath material: 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4876(M7), 2.4816(M8), Nicrobell® (M10) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) * Please contact COMECO! ** Order transmitter separately!!!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

DESIGN WITH ADJUSTABLE CONNECTION (TS(O)C3)


temperature probes

Ordering code

TS (1,2,3,4) - (MI -) G0.G1G2.G3.G4.G6.G7.G9'9".G10.G11.G14 - #1.#2

Code Feature or option

Code values

Base model variant

C - standard (w/ terminal block), OC - prepared for in-head transmitter (w/o terminal block)

G0

Protection head

B - type "B", CC - type "CC", CS - type "CS", D - type "D", DH - type "DH", DHW - type "DHW", DW - type "DW", E - type "E", EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", ES - type "ES", G - type "G", MA - type "MA", MB - type "MB", N - type "N"

G1

Number of thermocouples

1 or 2

G2

Thermocouple

G3

Temperature range

G4

Diameter 'd' [mm]

G6

Probe length 'n' [mm] (1)

50…50000 (see table overleaf)

G7

Probe length 'm' [mm] (2)

0…1500

G9'

Mounting connection

X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)

G9"

Compression fitting ferrule (4)

BR - brass, GR - graphite, SS - stainless steel, TF - Teflon®

G10

Sheath material (wetted parts)

regular design

E - type "E", J - type "J", K - type "K", L - type "L", R - type "R", S - type "S"

MI design

E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T" T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (8), T13 - 0…1000 °C, T16 - 0…1100 °C

regular design MI design

6, 8, 10, 12, 14, 16, 20, 22 3, 4.5, 6, 8, 10

regular design

M2 - 1.4541, M3 - 1.4571, M4 - 1.4762, M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4401 (1.4404), M15 - 1.4362

MI design

M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4401 (1.4404), M10 - Nicrobell®

G11

Accuracy class

1 - '1' (8), 2 - '2'

G14

Tip shape (hot junction)

X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design

#1

Options

X - none, OV - vibration proof (spring terminals (8), secured screws), OT - thermal isolation (3), OP - electrochemically polished sheath surface (5)

#2

Incorporated devices

X - none, T - in-head transmitter (6), A - local indicator (7)

(1)

'n+m' for TS(O)C3 and TS(O)C4! Only for TS(O)C1 and TS(O)C2! Only for TS(O)C! (4) Only for TS(O)C4! (5) Only for non-MI (regular) design! (6) Only for variant 'OC'! See transmitter datasheets and order separately! (7) With windowed head only! See indicator datasheets and order separately! (8) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes RTD PROBE WITH PROTECTION HEAD AND (MI) INSERT

TSCSx

- FOR IN-HEAD TRANSMITTER ** TSOCSx Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum, stainless steel, or plastic (see Appendix - Protection heads)

DIMENSIONS SENSITIVE ELEMENT

TEMPERATURE RANGE

d [mm]

d insert [mm]

wires

Regular Insert Design

DESIGN WITHOUT EXTENSION (TS(O)CS)

1 x Pt (RB,RD,RF,RG)

2 x Pt (RB,RD,RF,RG) 1 x Cu (RH, RK) 2 x Cu (RH, RK)

EXTENDED DESIGN WITH WELDED CONNECTION (TS(O)CS1) 1 x Pt (RB,RD,RF,RG)

2 x Pt (RB,RD,RF,RG)

T9 T1 T24 T11 T2 T4 T22 T9 T9

-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C -50...200 °C -50...200 °C

8

4, 5

2, 3*

9, 10, 12, 14, 16, 20

6

2, 3, 4*

12, 14, 16, 20

8

2, 3, 4

9, 10, 12, 14, 16, 20

6

2x2*

12, 14, 16, 20

8

2x2(3)*

9, 10, 12, 14, 16, 20

6

2, 3, 4*

12, 14, 16, 20

8

2, 3, 4

9, 10, 12, 14, 16, 20

6

2x2*

12, 14, 16, 20

8

2x2(3)*

3*

2, 3*

4.5

2, 3*

6

2, 3, 4*

MI Insert Design 6, 8, 9, 10, 12, 14, T9 -50...200 °C 16, 20 T1 -50...400 °C 8, 9, 10, 12, 14, T24 -50...500 °C 16, 20 T11 -50...600 °C 9, 10, 12, 14, 16, 20 T2 -200...600 °C 12, 14, 16, 20 0...800 °C 9, 10, 12, 14, 16, 20 T4 T22 -200...200 °C 12, 14, 16, 20

8

2, 3, 4

6

2x2, 2x3*

8

2x2, 2x3*

Protection head: B, MA, MB, G, N, Cx, Dx, Ex (see Appendix - Protection Heads)

EXTENDED DESIGN WITH MOVABLE CONNECTION (TS(O)CS2)

Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Thermal isolation between nipple and metal head: (for TS(O)CS only) Protection head

DESIGN WITH ADJUSTABLE CONNECTION (TS(O)CS3)

Length 'n'

Maximum temperature

Insulation material

MA, MB B

up to 50 mm up to 100 mm

200 °C

POM

other

up to 150 mm

400 °C

Teflon®

Extension length: m = 0…1500 mm Probe diameter 'd' Ext. length 'm'

6 mm

8 mm

9, 10 mm

10+ mm

up to 50 mm

d

d

d

d

50...150 mm

8

d

d

d

150...500 mm

10

10

d

d

500+ mm

14

14

14

d

Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes)

DESIGN WITH GLAND-TYPE CONNECTION (TS(O)CS4)

Process pressure: Probe design Max. pressure *

TS(O)CS, TS(O)CS1 TS(O)CS2 25 bar

16 bar

TS(O)CS4

TS(O)CS3

6 bar

0 bar

Sheath material: 1.4301(M1), 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362(M15) Wire material: Cu, Ni, or Ag Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) * Please contact COMECO! ** Order transmitter separately!!!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Extension diameter: (for TS(O)CS1 and TS(O)CS2 only, [mm])


temperature probes

Ordering code

TS (1,2,3,4) - (MI -) G0.G1G2.G3.G4.G6.G7.G9'9".G10.G11.G12.G13.G14 - #1.#2

Code Feature or option

Code values

Base model variant

CS - standard (w/ terminal block), OCS - prepared for in-head transmitter (w/o terminal block)

Protection head

B - type "B", CC - type "CC", CS - type "CS", D - type "D", DH - type "DH", DHW - type "DHW", DW - type "DW", E - type "E", EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", ES - type "ES", G - type "G", MA - type "MA", MB - type "MB", N - type "N"

G1

Number of RTD sensors

1 or 2

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100

G3

Temperature range

T1 - -50…400 °C, T2 - -200…600 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C, T22 - -200…200 °C, T24 - -50…500 °C

G4

Diameter 'd' / 'd insert' [mm]

G6

Probe length 'n' [mm] (1)

G0

G7

Probe length 'm' [mm]

regular insert

8/4, 8/5, 9/6, 10/6, 12/6, 14/6, 12/8, 14/8, 16/6, 16/8, 20/6, 20/8

MI insert

6/3 (12), 8/4.5, 9/6, 10/6, 12/6, 14/6, 16/6, 16/8, 20/6, 20/8 50…3000

(2)

0…1500

G9'

Mounting connection

X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)

G9"

Compression fitting ferrule (4)

TF - Teflon®, BR - brass, SS - stainless steel

G10

Sheath material (wetted parts and insert)

G11

Accuracy class

X - none (5), A - 'A', B - 'B', C - '2xB'

G12

Number of wires

2, 3, 4 (12)

G13

Wire material (6)

CU - copper (7), NI - nickel, AG - silver (8)

G14

Tip shape

X - standard closed, N - narrowed (12), P - pitted

#1

Options

X - none, OV - vibration proof (MgO or Silicone filled insert, secured screws) (8,9), OS - spring-loaded insert, OT - thermal isolation (3), OP - electrochemically polished wetted parts

#2

Incorporated devices

X - none, T - in-head transmitter (10), A - local indicator (11)

regular insert

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404), M15 - 1.4362 (12)

MI insert

M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404)

(1)

'n+m' for TS(O)CS3 and TS(O)CS4! Only for TS(O)CS1 and TS(O)CS2! Only for TS(O)CS! (4) Only for TS(O)CS4! (5) For non-Pt sensors (6) Only for Pt sensors! (7) Not applicable to non-MI (regular) RTD inserts for above 500 °C! (8) Only for non-MI (regular) inserts! (9) Requires 'OS' option! (10) Only for variant 'OCS'! See transmitter datasheets and order separately! (11) With windowed head only! See indicator datasheets and order separately! (12) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes T/C PROBE WITH PROTECTION HEAD AND (MI) INSERT

TSCSx

- FOR IN-HEAD TRANSMITTER ** TSOCSx Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum, stainless steel, or plastic (see Appendix - Protection heads)

DIMENSIONS SENSITIVE ELEMENT

TEMPERATURE RANGE

d [mm]

d insert [mm]

wires

Regular Insert Design

DESIGN WITHOUT EXTENSION (TS(O)CS)

10, 12, 14, 16, 20

6, 8, 10

2

12, 14, 16, 20

8, 10

2x2

0...850 °C 0...1100 °C 0...1150 °C

10, 12, 14, 16, 20

6, 8, 10

2

12, 14, 16, 20

8, 10

2x2

0...850 °C 0...1000 °C

10, 12, 14, 16, 20

6, 8, 10

2

2xE

T3 T13

12, 14, 16, 20

8, 10

2x2

1xS 1xR

T16 T6*

0...1100 °C 0...1150 °C

10, 12, 14, 16, 20

6, 8, 10

2

2xS 2xR

T16 T6*

0...1100 °C 0...1150 °C

12, 14, 16, 20

8, 10

2x2

1 x J; 1 x L 2 x J; 2 x L 1xK 2xK 1xE

EXTENDED DESIGN WITH WELDED CONNECTION (TS(O)CS1)

T4

0...800 °C

T3 T16 T6*

MI Insert Design 1xJ 2xJ 1xK 1 x N, 1 x E 2xK 2 x N, 2 x E

T4

0...800 °C

6, 8, 10, 12, 14, 16, 20

3, 4.5, 6, 8

T3 T16 T6* T6*

0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C

8, 10, 12, 14, 16, 20

4.5, 6, 8

2 2x2 2 2x2

Protection head: B, MA, MB, G, N, Cx, Dx, Ex (see Appendix - Protection Heads)

EXTENDED DESIGN WITH MOVABLE CONNECTION (TS(O)CS2)

Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Thermal isolation between nipple and metal head: (for TS(O)CS only) Protection head

DESIGN WITH ADJUSTABLE CONNECTION (TS(O)CS3)

Length 'n' up to 50 mm

Maximum temperature

B

up to 100 mm

200 °C

POM

other

up to 150 mm

400 °C

Teflon®

MA, MB

Insulation material

Process length: n = 50…3000 mm Extension length: m = 0…1500 mm Probe diameter 'd' Ext. length 'm'

DESIGN WITH GLAND-TYPE CONNECTION (TS(O)CS4)

6 mm

8 mm

10 mm

10+ mm d

up to 50 mm

d

d

d

50...150 mm

8

d

d

d

150...500 mm

10

10

d

d

500+ mm

14

14

14

d

Insert tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Process pressure: Probe design Max. pressure *

TS(O)CS, TS(O)CS1 TS(O)CS2 25 bar

16 bar

TS(O)CS4

TS(O)CS3

6 bar

0 bar

Sheath material: 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762/1.4749(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362(M15) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) * Please contact COMECO! ** Order transmitter separately!!!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Extension diameter: (for TS(O)CS1 and TS(O)CS2 only, [mm])


temperature probes

Ordering code

TS (1,2,3,4) - (MI -) G0.G1G2.G3.G4.G6.G7.G9'9".G10.G11.G14 - #1.#2

Code Feature or option

Code values

Base model variant

CS - standard (w/ terminal block), OCS - prepared for in-head transmitter (w/o terminal block)

G0

Protection head

B - type "B", CC - type "CC", CS - type "CS", D - type "D", DH - type "DH", DHW - type "DHW", DW - type "DW", E - type "E", EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", ES - type "ES", G - type "G", MA - type "MA", MB - type "MB", N - type "N"

G1

Number of thermocouples

1 or 2 regular insert

E - type "E", J - type "J", K - type "K", L - type "L", R - type "R", S - type "S"

MI insert

E - type "E", J - type "J", K - type "K", N - type "N"

G2

Thermocouple

G3

Temperature range

G4

Diameter 'd' / 'd insert' [mm]

G6

Probe length 'n' [mm] (1)

50…3000

G7

Probe length 'm' [mm] (2)

0…1500

G9'

Mounting connection

X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)

G9"

Compression fitting ferrule (4)

G10

Sheath material (wetted parts and insert)

T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (8), T13 - 0…1000 °C, T16 - 0…1100 °C regular insert

10/6, 10/8, 12/6, 12/8, 14/6, 14/8, 14/10, 16/10, 20/10

MI insert

6/3, 8/4.5, 10/6, 12/6, 14/6, 16/6, 20/6, 20/8

TF - Teflon®, BR - brass, SS - stainless steel

regular insert

M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4401 (1.4404), M15 - 1.4362

MI insert

M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M8 - 2.4816, M9 - 1.4401 (1.4404)

G11

Accuracy class

1 - '1' (8), 2 - '2'

G14

Insert tip shape (hot junction)

X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design

#1

Options

X - none, OV - vibration proof (secured screws) (5), OS - spring-loaded insert, OT - thermal isolation (3), OP - electrochemically polished wetted parts

#2

Incorporated devices

X - none, T - in-head transmitter (6), A - local indicator (7)

(1)

'n+m' for TS(O)CS3 and TS(O)CS4! Only for TS(O)CS1 and TS(O)CS2! Only for TS(O)CS! (4) Only for TS(O)CS4! (5) Requires 'OS' option! (6) Only for variant 'OCS'! See transmitter datasheets and order separately! (7) With windowed head only! See indicator datasheets and order separately! (8) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes ANGLED RTD PROBE WITH PROTECTION HEAD

Lx (TSLx)

(FOR IN-HEAD TRANSMITTER)** OLx (TSOLx) Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum, stainless steel, or plastic (see Appendix - Protection heads) DESIGN WITHOUT FLANGE (L)

DIMENSIONS SENSITIVE ELEMENT

TEMPERATURE RANGE

-50...200 °C -50...400 °C -50...600 °C -200...600 °C -0...800 °C

d [mm]

wires

2(3) x Pt (RB,RD,RF,RG)

T9 T1 T11 T2 T4

1 x Cu (RH, RK)

T9

-50...200 °C

10, 12, 14, 16, 20, 22

2, 3, 4*

2 x Cu (RH, RK)

T9

-50...200 °C

12, 14, 16, 20, 22

2x2(3)*

1 x Pt (RB,RD,RF,RG)

10, 12, 14, 16, 20, 22

2, 3, 4*

12, 14, 16, 20, 22

2x2(3)* 3x2*

Protection head: B, MA, MB, G, N, Dx, Ex, EX (see Appendix - Protection heads) Process connection: - welded flange - adjustable flange - no mounting appliances Insertion length: n = 200…1500 mm

DESIGN WITH WELDED FLANGE (L1)

Extension length: m = 100…1000 mm Holding tube: - m1 = 100…1000 mm - OD 20(22) mm - tube/elbow material 1.4301 or 1.4541 Tip shape: standard, narrowed, pitted (see Appendix - Tip shapes) Process pressure: Probe design Max. pressure *

L, L1

L3

25 bar

0 bar

Sheath material: 1.4301(M1), 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362 (M15) Wire material: Cu, Ni, or Ag

DESIGN WITH ADJUSTABLE FLANGE (L3)

* Please contact COMECO! ** Order transmitter separately!!!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance)


temperature probes

Ordering code

TS (1,3) - G0.G1G2.G3.G4.G6.G7'.G7".G9.G10.G11.G12.G13.G14 - #1.#2

Code Feature or option

Code values

Base model variant

L - standard (w/ terminal block), OL - prepared for in-head transmitter (w/o terminal block)

G0

Protection head

B - type "B", MA - type "MA", MB - type "MB", G - IP65, type "G", N - type "N", D - type "D", DW - windowed, type "DW", DH - w/ high cap, type "DH", DHW - windowed, type "DHW", E - IP65, type "E", ES - stainless-steel, type "ES", EG - IP68 ATEX-approved, type "EG", EGS - IP66 ATEX-approved, type "EGS", EGW - windowed ATEX-approved, type "EGW", EX - explosion-proof instrument housing (specify!)

G1

Number of RTD sensors

1, 2, or 3 (6)

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100

G3

Temperature range

T1 - -50…400 °C, T2 - -200…600 °C (Ni or Ag wires only!), T4 - 0…800 °C (Ag wires only!), T9 - -50…200 °C, T11 - -50…600 °C (Ni or Ag wires only!)

G4

Diameter 'd' [mm]

10, 12, 14, 16, 20, 22

G6

Probe length 'n' [mm] (1)

200…1500

G7'

Probe length 'm' [mm] (2)

100…1000

G7"

Probe length 'm1' [mm]

100…1000

G9

Mounting connection

X - no mounting appliances, F - flange (specify!), Z - other connection (specify!)

G10

Sheath material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404, M15 - 1.4362

G11

Accuracy class (3)

A - 'A', B - 'B', C - '2xB'

G12

Number of wires

2, 3, 4 (6)

(3)

G13

Wire material

CU - copper, NI - nickel, AG - silver

G14

Tip shape

X - standard closed, N - narrowed, P - pitted (4)

#1

Options

X - none, OV - vibration proof (MgO or Silicone filled, secured screws), OP - electrochemically polished sheath surface

#2

Local indicator

X - none, A - local indicator mounted (5)

(1)

'n+m' for TS(O)L3! Only for TS(O)L1! Only for Pt sensors! (4) Only for non-explosion-proof RTDs! (5) With windowed head only! See indicator datasheets and order separately! (6) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes ANGLED T/C PROBE WITH PROTECTION HEAD

Lx (TSLx)

(FOR IN-HEAD TRANSMITTER)** OLx (TSOLx) Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum, stainless steel, or plastic (see Appendix - Protection heads)

DIMENSIONS SENSITIVE ELEMENT

TEMPERATURE RANGE

d [mm]

wires

Regular Thermocouple Design

DESIGN WITHOUT FLANGE (L)

T4

0...800 °C

10, 12, 14, 16, 20, 22

T3 T16 T6*

0...850 °C 0...1100 °C 0...1150 °C

10, 12, 14, 16, 20, 22

2xE

T3 T13

0...850 °C 0...1000 °C

10, 12, 14, 16, 20, 22

1xS 1xR

T16 T6*

0...1100 °C 0...1150 °C

10, 12, 14, 16, 20, 22

2

2xS 2xR

T16 T6*

0...1100 °C 0...1150 °C

10, 12, 14, 16, 20, 22

2x2

1xJ

T4

0...800 °C

10

2

1xK 1 x N; 1 x E

T3 T16

0...850 °C 0...1100 °C

10

2

2xK

T3 T16

0...850 °C 0...1100 °C

10

2x2

1 x J; 1 x L 2 x J; 2 x L 1xK 2xK 1xE

2 2x2 2 2x2 2 2x2

MI Thermocouple Design

DESIGN WITH WELDED FLANGE (L1)

Protection head: B, MA, MB, G, N, Dx, Ex, EX (see Appendix - Protection heads) Process connection: - welded flange - adjustable flange - no mounting appliances Insertion length: n = 200…1500 mm Extension length: m = 100…1000 mm Holding tube: - m1 = 100…1000 mm - OD 20(22) mm - material 1.4301 or 1.4541 Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip shapes) Process pressure: Probe design Max. pressure *

L, L1

L3

25 bar

0 bar

Sheath material: 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362 (M15) MI sheath material: 1.4541(M2), 1.4571(M3), 1.4876(M7), 2.4816(M8) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)

* Please contact COMECO! ** Order transmitter separately!!!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

DESIGN WITH ADJUSTABLE FLANGE (L3)


temperature probes

Ordering code

TS (1,3) - G0.G1G2.G3.G4.G6.G7'.G7".G9.G10.G11.G14 - #1.#2

Code Feature or option

Code values

Base model variant

L - standard (w/ terminal block), OL - prepared for in-head transmitter (w/o terminal block)

G0

Protection head

B - type "B", MA - type "MA", MB - type "MB", G - IP65, type "G", N - type "N", D - type "D", DW - windowed, type "DW", DH - w/ high cap, type "DH", DHW - windowed, type "DHW", E - IP65, type "E", ES - stainless-steel, type "ES", EG - IP68 ATEX-approved, type "EG", EGS - IP66 ATEX-approved, type "EGS", EGW - windowed ATEX-approved, type "EGW", EX - explosion-proof instrument housing (specify!)

G1

Number of thermocouples

1 or 2

G2

Thermocouple

J - type "J", K - type "K", N - type "N", E - type "E", L - type "L", S - type "S", R - type "R"

G3

Temperature range

T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (5), T13 - 0…1000 °C, T16 - 0…1100 °C

G4

Diameter 'd' [mm]

G6

Probe length 'n' [mm] (1)

200…1500

G7'

Probe length 'm' [mm] (2)

100…1000

G7"

Probe length 'm1' [mm]

100…1000

G9

Mounting connection

X - no mounting appliances, F - flange (specify!), Z - other connection (specify!)

G10

Sheath material

M2 - 1.4541, M3 - 1.4571, M4 - 1.4762, M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4404, M15 - 1.4362

G11

Accuracy class

1 - '1' (5), 2 - '2'

G14

Tip shape (hot junction)

X - standard (isolated from sheath), G - grounded, E - exposed hot junction (3), O - open-tube design (3)

#1

Options

X - none, OV - vibration proof (spring-type terminals (5), secured screws), OP - electrochemically polished sheath surface

#2

Local indicator

X - none, A - local indicator mounted (4)

regular T/C MI T/C

regular T/C MI T/C

10, 12, 14, 16, 20, 22 10

M2 - 1.4541, M3 - 1.4571, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600)

(1)

'n+m' for TS(O)L3! Only for TS(O)L1! Only for non-explosion-proof thermocouples! (4) With windowed head only! See indicator datasheets and order separately! (5) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes RTD PROBE WITH PROTECTION HEAD AND OPEN REPLACEABLE INSERT FOR THERMOWELL OR PROTECTION TUBE

DSx (TSDSx)

(FOR IN-HEAD TRANSMITTER)** ODSx (TSODSx) Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum, stainless steel, or plastic (see Appendix - Protection heads) DESIGN WITHOUT EXTENSION (DS)

DIMENSIONS SENSITIVE ELEMENT

TEMPERATURE RANGE

-50...200 °C -50...400 °C -50...600 °C -200...600 °C -0...800 °C

2 x Pt (RB,RD,RF,RG)

T9 T1 T11 T2 T4

1 x Cu (RH, RK)

T9

-50...200 °C

2 x Cu (RH, RK)

T9

-50...200 °C

1 x Pt (RB,RD,RF,RG)

D [mm]

d [mm]

wires

8, 10 10, 12 12, 14

5 6 8

2, 3* 2, 3, 4* 2, 3, 4

10, 12 12, 14 10, 12 12, 14 10, 12 12, 14

6 8 6 8 6 8

2x2* 2x2(3)* 2, 3, 4* 2, 3, 4 2x2* 2x2(3)*

Protection head: B, MA, MB, G, N, Dx, Ex, EX (see Appendix - Protection heads)

EXTENDED DESIGN WITH WELDED CONNECTION (DS1)

Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded flange Thermal isolation between nipple and metal head: (for TS(O)DS only) Protection head

EXTENDED DESIGN WITH MOVABLE CONNECTION (DS2)

Length 'n' up to 50 mm

Maximum temperature

B

up to 100 mm

200 °C

POM

other

up to 150 mm

400 °C

Teflon®

MA, MB

Insulation material

Insertion length (must fit thermowell / protection tube length 'L'!): n = 50…2000 mm Extension length: m = 50…1000 mm (w/o spring-loaded adapter) m = m1...1000 mm (w/ spring-loaded adapter) Tip shape: standard, narrowed, pitted (see Appendix - Tip shapes) Process pressure: - with metal thermowell up to 500 bar (see Accessories - Thermowells) - with ceramic protection tube (see Accessories - Protection tubes) *

DESIGN WITH SLIDING GLAND-TYPE CONNECTION (DS4)

Sheath material: 1.4301(M1) or 1.4541(M2)

Wire material: Cu, Ni, or Ag Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Spring-loaded adapter: (mounted between probe and protection head)

DESIGN WITH NIPPLE-UNION-NIPPLE CONNECTION (DS5)

m1

20...25

* Please contact COMECO! ** Order transmitter separately!!!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

m1 = 60…100 mm

COMECO reserves the right of changing specifications without prior notice!

Insert sheath material: 1.4301(M1), 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362 (M15)


temperature probes

Ordering code

TS (1,2,4,5) - G0.G1G2.G3.G4.G6.G7.G9'9".G10.G11.G12.G13.G14 - #1.#2

Code Feature or option

Code values

Base model variant

DS - standard (w/ terminal block), ODS - prepared for in-head transmitter (w/o terminal block)

G0

Protection head

B - type "B", MA - type "MA", MB - type "MB", G - IP65, type "G", N - type "N", D - type "D", DW - windowed, type "DW", DH - w/ high cap, type "DH", DHW - windowed, type "DHW", E - IP65, type "E", ES - stainless-steel, type "ES", EG - IP68 ATEX-approved, type "EG", EGS - IP66 ATEX-approved, type "EGS", EGW - windowed ATEX-approved, type "EGW", EX - explosion-proof instrument housing (specify!)

G1

Number of RTD sensors

1 or 2

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100

G3

Temperature range

T1 - -50…400 °C, T2 - -200…600 °C (Ni or Ag wires only!), T4 - 0…800 °C (Ag wires only!), T9 - -50…200 °C, T11 - -50…600 °C (Ni or Ag wires only!)

G4

Diameters 'D/d' [mm] (1)

8/5, 10/5, 10/6, 12/6, 14/6, 14/8, 20/6, 21/6, 20/8, 21/8

G6

Probe length 'n' [mm]

50…2000

G7

Probe length 'm' [mm] (2)

50…1000 (m1…1000 with 'OA' option)

G9'

Mounting connection

X - no mounting appliances, Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)

G9"

Compression fitting ferrule (3)

TF - Teflon®, BR - brass, SS - stainless steel

G10

Insert sheath material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404, M15 - 1.4362

(4)

G11

Accuracy class

G12

Number of wires

A - 'A', B - 'B', C - '2xB' 2, 3, 4 (10)

G13

Wire material (4)

CU - copper, NI - nickel, AG - silver

G14

Tip shape

X - standard closed, N - narrowed, P - pitted (5)

#1

Options

X - none, OV - vibration proof (MgO or Silicone filled insert, secured screws) (6), OS - spring-loaded insert, OT - thermal isolation (7), OA - spring-loaded adapter (8), OP - electrochemically polished sheath surface

#2

Local indicator

X - none, A - local indicator mounted (9)

(1)

Only 'd' for TS(O)DS! Omit for TS(O)DS without 'OA' option! (3) Only for TS(O)DS4! (4) Only for Pt sensors! (5) Only for non-explosion-proof RTDs! (6) Requires 'OS' option! (7) Only for TS(O)DS! (8) Only for TS(O)DS, TS(O)DS1, and TS(O)DS5! Insert is not replaceable! (9) With windowed head only! See indicator datasheets and order separately! (10) Contact COMECO!

COMECO reserves the right of changing specifications without prior notice!

(2)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes T/C PROBE WITH PROTECTION HEAD AND OPEN REPLACEABLE INSERT FOR THERMOWELL OR PROTECTION TUBE

DSx (TSDSx)

(FOR IN-HEAD TRANSMITTER)*** ODSx (TSODSx) Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum, stainless steel, or plastic (see Appendix - Protection heads)

DIMENSIONS SENSITIVE ELEMENT

TEMPERATURE RANGE

D [mm]

d [mm]

wires

MI Thermocouple Insert Design

DESIGN WITHOUT EXTENSION (DS)

1xJ

2

T4

0...800 °C

8,10,12,14

3, 4.5, 6, 8

T3 T16 T6* T6*

0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C

8,10,12,14

3, 4.5, 6, 8

1 x S, 1 x R

T16 T6*

0...1100 °C 0...1150 °C

8,10,12,14

3, 4.5, 6

2

2 x S, 2 x R

T16 T6* T14** T15**

0...1100 °C 0...1150 °C 0...1600 °C 0...1700 °C

8,10,12,14

3, 4.5, 6

2x2

2xJ 1xK 1 x N, 1 x E 2xK 2 x N, 2 x E

EXTENDED DESIGN WITH WELDED CONNECTION (DS1)

2x2 2 2x2

Protection head: B, MA, MB, G, N, Dx, Ex, EX (see Appendix - Protection heads) Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded flange Thermal isolation between nipple and metal head: (for TS(O)DS only) Protection head

EXTENDED DESIGN WITH MOVABLE CONNECTION (DS2)

Length 'n'

MA, MB

up to 50 mm

Maximum temperature

B other

up to 100 mm up to 150 mm

200 °C 400 °C

Insulation material POM Teflon®

Insertion length (must fit thermowell / protection tube length 'L'!): n = 50…2000 mm Extension length: m = 50…1000 mm (w/o spring-loaded adapter) m = m1...1000 mm (w/ spring-loaded adapter) Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip shapes) Process pressure: - with metal thermowell up to 500 bar (see Accessories - Thermowells) - with ceramic protection tube (see Accessories - Protection tubes) * Sheath material: 1.4301(M1) or 1.4541(M2) MI-insert sheath material: 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4876(M7), 2.4816(M8) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)

DESIGN WITH NIPPLE-UNION-NIPPLE CONNECTION (DS5)

Spring-loaded adapter: (mounted between probe and protection head)

m1

20...25

* Please contact COMECO! ** With ceramic protection tubes only! *** Order transmitter separately!!!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

m1 = 60…100 mm

COMECO reserves the right of changing specifications without prior notice!

DESIGN WITH SLIDING GLAND-TYPE CONNECTION (DS4)


temperature probes

Ordering code

TS (1,2,4,5) - G0.G1G2.G3.G4.G6.G7.G9'9".G10.G11.G14 - #1.#2

Code Feature or option

G0

Code values

Base model variant

DS - standard (w/ terminal block), ODS - prepared for in-head transmitter (w/o terminal block)

Protection head

B - type "B", MA - type "MA", MB - type "MB", G - IP65, type "G", N - type "N", D - type "D", DW - windowed, type "DW", DH - w/ high cap, type "DH", DHW - windowed, type "DHW", E - IP65, type "E", ES - stainless-steel, type "ES", EG - IP68 ATEX-approved, type "EG", EGS - IP66 ATEX-approved, type "EGS", EGW - windowed ATEX-approved, type "EGW", EX - explosion-proof instrument housing (specify!)

G1

Number of thermocouples

1 or 2

G2

Thermocouple

J - type "J", K - type "K", N - type "N", E - type "E", L - type "L", S - type "S", R - type "R"

G3

Temperature range

T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (9), T13 - 0…1000 °C, T14 - 0…1600 °C, T15 - 0…1700 °C, T16 - 0…1100 °C

G4

Diameters 'D/d' [mm] (1)

8/3, 10/3, 8/4.5, 10/4.5, 12/6, 14/6, 20/6 (2), 21/6, 20/8 (2), 21/8

G6

Probe length 'n' [mm]

50…2000

G7

Probe length 'm' [mm] (3)

50…1000 (m1…1000 with 'OA' option)

G9'

Mounting connection

X - no mounting appliances, Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)

G9"

Compression fitting ferrule (4)

TF - Teflon®, BR - brass, SS - stainless steel

G10

Insert sheath material

M2 - 1.4541, M3 - 1.4571, M4 - 1.4762, M5 - 1.4841, M6 - 1.4845, M8 - 2.4816, M9 - 1.4404

G11

Accuracy class

1 - '1' (9), 2 - '2'

G14

Insert tip shape (hot junction)

X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design

#1

Options

X - none, OV - vibration proof (secured screws) (5), OS - spring-loaded insert, OT - thermal isolation (6), OA - spring-loaded adapter (7), OP - electrochemically polished sheath surface

#2

Local indicator

X - none, A - local indicator mounted (8)

(1)

Only 'd' for TS(O)DS! Not available with G10='M6' Omit for TS(O)DS without 'OA' option! (4) Only for TS(O)DS4! (5) Requires 'OS' option! (6) Only for TS(O)DS! (7) Only for TS(O)DS, TS(O)DS1, and TS(O)DS5! Insert is not replaceable! (8) With windowed head only! See indicator datasheets and order separately! (9) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

(MI) T/C PROBE WITH PROTECTION HEAD AND CERAMIC PROTECTION TUBE

TSZx

- FOR IN-HEAD TRANSMITTER ** TSOZx Holding tube - stainless steel 1.4301 or 1.4404 Protection tube - ceramic (see Accessories - Protection tubes) Head - aluminum, stainless steel, iron, or plastic (see Appendix - Protection heads)

WIRE [mm] SENSITIVE TEMPERATURE TUBE / ELEMENT RANGE MATERIAL MI [mm]

DIMENSIONS d [mm]

D [mm]

Regular Design T13

STRAIGHT DESIGN (TS(O)Z)

T6

0...1000 °C 0...1200 °C

1.0

C1(2),C6

10

16

C1(2)

15

22

C6, C7

16, 19

22, 24

C5

17

24

C1(2)

24

32

C4, C7

22, 28

30, 36

C5

23

30

C6

25, 32

32, 40

C1(2)

10,15,24

16,22,32

C4

22

30

C5

17, 23

24, 30

1.5

1 x K; 1 x N 2 X K, 2 X N T6

T21

0...1200 °C

0...1300 °C

3.0

0.35

C6 10,16,19,25 16,22,24,32 1 x S; 1 x R 2 X S, 2 X R T5

ANGLED DESIGN (TS(O)ZL)

0...1500 °C

0.35, 0.5

T14

0...1600 °C

0.5

1 x B; 2 x B

T14

0...1600 °C

0.35

1 x B; 2 x B

T15

0...1700 °C

0.5

T16

0...1100 °C

C7*

16,22,28

22,30,36

C1(2)

10,15,24

16,22,32

C5

17, 23

24, 30

C6 10,16,19,25 16,22,24,32 C2

10,15,24

16,22,32

C6 10,16,19,25 16,22,24,32 C2

10,15,24

16,22,32

C6 10,16,19,25 16,22,24,32 C3

10,15,24

16,22,32

C6* 10,16,19,25 16,22,24,32

1 x K; 1 x N 2 X K, 2 X N

T16 0...1100 °C (Inconel 600) T6 0...1200 °C (Nicrobell®)

1 x S, 2 x S

n = 200…nmax nmax can be defined from the table below: n [mm] ≤ 400 ≤ 800 ≤ 1800

d≤ single L - 50 L - 70 L - 100

16 double L - 70 L - 100 L - 100

d ≤ 32 any L - 100 L - 100 L - 100

where 'L' is the length of the protection tube (see Accessories - Protection Tubes) Holding tube: - m1 = 100…1000 mm - OD 20(22) mm - tube/elbow material 1.4301 or 1.4541

T16 0...1100 °C (Inconel 600)

10

16

C1

15

22

C6, C7

16, 19

22, 24

C5

17, 23

24, 30

3, 4.5, 6, 8, 10

C1

24

32

C4, C7

22, 28

30, 36

C6

25, 32

32, 40

3, 4.5

C1, C6

10

16

C1

15

22

C6, C7

16, 19

22, 24

C5

17, 23

24, 30

3, 4.5, 6, 8

3, 4.5, 6

Protection head: B, MA, MB, G, N, Cx, Dx, Ex (see Appendix - Protection Heads) Process connection: - welded or adjustable flange - w/o mounting appliances Extension length: m = 100…1000 mm Extension tube material: 1.4301(M1), 1.4541(M2), 1.4404(M9), 1.4571(M3) MI sheath material: 2.4816(M8), Nicrobell® (M10) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) * Please contact COMECO! ** Order transmitter separately!!!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

C1, C6

3, 4.5

COMECO reserves the right of changing specifications without prior notice!

MI Design


temperature probes

Ordering code

TS (L) - (MI -) G0.G1G2.G3.G4.G5.G6.G7'.G7".G9.G10'.G10".G11 - #1

Code Feature or option

Code values

Base model variant

Z - standard (w/ terminal block), OZ - prepared for in-head transmitter (w/o terminal block)

Protection head

B - type "B", CC - type "CC", CS - type "CS", D - type "D", DH - type "DH", DHW - type "DHW", DW - type "DW", E - type "E", EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", ES - type "ES", G - type "G", MA - type "MA", MB - type "MB", N - type "N"

G1

Number of thermocouples

1 or 2

G2

Thermocouple Check wire-to-sheath compatibility in the specification table!

G0

regular design MI design

B - type "B", K - type "K", N - type "N", R - type "R", S - type "S" K - type "K", N - type "N", S - type "S" T5 - 0…1500 °C, T6 - 0…1200 °C, T13 - 0…1000 °C, T14 - 0…1600 °C, T15 - 0…1700 °C, T16 - 0…1100 °C, T21 - 0…1300 °C

G3

Temperature range

G4

Diameter 'd' [mm]

G5

Diameter 'D' [mm]

16, 22, 24, 30, 32, 36, 40

G6

Probe length 'n' [mm]

200…1800 (see table overleaf)

G7'

Probe length 'm' [mm]

100…1000

G7"

Probe length 'm1' [mm]

100…1000

G9

Mounting connection

X - no mounting appliances, F - flange (specify!), Z - other connection (specify!)

G10'

Protection tube material

C1 - ceramic Pythagoras 610, C2 - ceramic Oxal 710, C3 - ceramic Alsint 799, C4 - metal-ceramic Ucar®, C5 - silicon carbide, C6 - Hexoloy®, C7 - Syalon

G10"

Extension tube material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

G11

Accuracy class

1 - '1' (3), 2 - '2'

#1

Incorporated devices

X - none, T - in-head transmitter (1), A - local indicator (2)

single tube

10, 15, 16, 17, 19, 22, 23, 24, 25, 28, 32 (see table overleaf)

double tube

24/10, 24/15, etc. (see 'Accessories - Protection Tubes YA' for available combinations!)

(1)

Only for variant 'OZ'! See transmitter datasheets and order separately! With windowed head only! See indicator datasheets and order separately! (3) Contact COMECO!

COMECO reserves the right of changing specifications without prior notice!

(2)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes (MI) T/C PROBE WITH PROTECTION HEAD AND CERAMIC PROTECTION TUBE

TSZx

- FOR IN-HEAD TRANSMITTER ** TSOZx Holding tube - stainless steel 1.4301 or 1.4404 Protection tube - ceramic (see Accessories - Protection tubes) Head - aluminum, stainless steel, iron, or plastic (see Appendix - Protection heads)

WIRE [mm] SENSITIVE TEMPERATURE TUBE / ELEMENT RANGE MATERIAL MI [mm]

DIMENSIONS d [mm]

D [mm]

Regular Design T13

STRAIGHT DESIGN (TS(O)Z)

T6

0...1000 °C 0...1200 °C

1.0

C1(2),C6

10

16

C1(2)

15

22

C6, C7

16, 19

22, 24

C5

17

24

C1(2)

24

32

C4, C7

22, 28

30, 36

C5

23

30

C6

25, 32

32, 40

C1(2)

10,15,24

16,22,32

C4

22

30

C5

17, 23

24, 30

1.5

1 x K; 1 x N 2 X K, 2 X N T6

T21

0...1200 °C

0...1300 °C

3.0

0.35

C6 10,16,19,25 16,22,24,32 1 x S; 1 x R 2 X S, 2 X R T5

ANGLED DESIGN (TS(O)ZL)

0...1500 °C

0.35, 0.5

T14

0...1600 °C

0.5

1 x B; 2 x B

T14

0...1600 °C

0.35

1 x B; 2 x B

T15

0...1700 °C

0.5

T16

0...1100 °C

C7*

16,22,28

22,30,36

C1(2)

10,15,24

16,22,32

C5

17, 23

24, 30

C6 10,16,19,25 16,22,24,32 C2

10,15,24

16,22,32

C6 10,16,19,25 16,22,24,32 C2

10,15,24

16,22,32

C6 10,16,19,25 16,22,24,32 C3

10,15,24

16,22,32

C6* 10,16,19,25 16,22,24,32

1 x K; 1 x N 2 X K, 2 X N

T16 0...1100 °C (Inconel 600) T6 0...1200 °C (Nicrobell®)

1 x S, 2 x S

n = 200…nmax nmax can be defined from the table below: n [mm] ≤ 400 ≤ 800 ≤ 1800

d≤ single L - 50 L - 70 L - 100

16 double L - 70 L - 100 L - 100

d ≤ 32 any L - 100 L - 100 L - 100

where 'L' is the length of the protection tube (see Accessories - Protection Tubes) Holding tube: - m1 = 100…1000 mm - OD 20(22) mm - tube/elbow material 1.4301 or 1.4541

T16 0...1100 °C (Inconel 600)

10

16

C1

15

22

C6, C7

16, 19

22, 24

C5

17, 23

24, 30

3, 4.5, 6, 8, 10

C1

24

32

C4, C7

22, 28

30, 36

C6

25, 32

32, 40

3, 4.5

C1, C6

10

16

C1

15

22

C6, C7

16, 19

22, 24

C5

17, 23

24, 30

3, 4.5, 6, 8

3, 4.5, 6

Protection head: B, MA, MB, G, N, Cx, Dx, Ex (see Appendix - Protection Heads) Process connection: - welded or adjustable flange - w/o mounting appliances Extension length: m = 100…1000 mm Extension tube material: 1.4301(M1), 1.4541(M2), 1.4404(M9), 1.4571(M3) MI sheath material: 2.4816(M8), Nicrobell® (M10) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) * Please contact COMECO! ** Order transmitter separately!!!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

C1, C6

3, 4.5

COMECO reserves the right of changing specifications without prior notice!

MI Design


temperature probes

Ordering code

TS (L) - (MI -) G0.G1G2.G3.G4.G5.G6.G7'.G7".G9.G10'.G10".G11 - #1

Code Feature or option

Code values

Base model variant

Z - standard (w/ terminal block), OZ - prepared for in-head transmitter (w/o terminal block)

Protection head

B - type "B", CC - type "CC", CS - type "CS", D - type "D", DH - type "DH", DHW - type "DHW", DW - type "DW", E - type "E", EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", ES - type "ES", G - type "G", MA - type "MA", MB - type "MB", N - type "N"

G1

Number of thermocouples

1 or 2

G2

Thermocouple Check wire-to-sheath compatibility in the specification table!

G0

regular design MI design

B - type "B", K - type "K", N - type "N", R - type "R", S - type "S" K - type "K", N - type "N", S - type "S" T5 - 0…1500 °C, T6 - 0…1200 °C, T13 - 0…1000 °C, T14 - 0…1600 °C, T15 - 0…1700 °C, T16 - 0…1100 °C, T21 - 0…1300 °C

G3

Temperature range

G4

Diameter 'd' [mm]

G5

Diameter 'D' [mm]

16, 22, 24, 30, 32, 36, 40

G6

Probe length 'n' [mm]

200…1800 (see table overleaf)

G7'

Probe length 'm' [mm]

100…1000

G7"

Probe length 'm1' [mm]

100…1000

G9

Mounting connection

X - no mounting appliances, F - flange (specify!), Z - other connection (specify!)

G10'

Protection tube material

C1 - ceramic Pythagoras 610, C2 - ceramic Oxal 710, C3 - ceramic Alsint 799, C4 - metal-ceramic Ucar®, C5 - silicon carbide, C6 - Hexoloy®, C7 - Syalon

G10"

Extension tube material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

G11

Accuracy class

1 - '1' (3), 2 - '2'

#1

Incorporated devices

X - none, T - in-head transmitter (1), A - local indicator (2)

single tube

10, 15, 16, 17, 19, 22, 23, 24, 25, 28, 32 (see table overleaf)

double tube

24/10, 24/15, etc. (see 'Accessories - Protection Tubes YA' for available combinations!)

(1)

Only for variant 'OZ'! See transmitter datasheets and order separately! With windowed head only! See indicator datasheets and order separately! (3) Contact COMECO!

COMECO reserves the right of changing specifications without prior notice!

(2)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

ANGLED RTD PROBE WITH PROTECTION HEAD FOR PROTECTION TUBE ASSEMBLY

LDx (TSLDx)

(FOR IN-HEAD TRANSMITTER)** OLDx (TSOLDx) Holding tube - stainless steel 1.4301 or 1.4404 Protection tube - metal (see Accessories - Protection tubes) Head - aluminum, stainless steel, or plastic (see Appendix - Protection heads)

DIMENSIONS SENSITIVE ELEMENT

TEMPERATURE RANGE

2 x Pt (RB,RD,RF,RG)

T9 T1 T11 T2 T4

1 x Cu (RH, RK)

T9

1 x Pt (RB,RD,RF,RG)

2 x Cu (RH, RK)

T9

-50...200 °C -50...400 °C -50...600 °C -200...600 °C -0...800 °C

d [mm]

wires

6

2, 3, 4*

8, 10, or bare

2, 3, 4

6*, 8, 10, or bare

2x2

6 or bare

2, 3

8, 10, or bare

2, 3, 4*

8, 10, or bare

2x2

-50...200 °C

-50...200 °C

Protection head: B, MA, MB, G, N, Dx, Ex, EX (see Appendix - Protection heads) Process connection (must fit the YA connection 'G'): G1/2"(Q4), G3/4"(Q6), male or female (see Accessories - Protection tubes) Insertion length (must fit the YA length 'L'): n = 100…1000 mm Holding tube: - m1 = 100…1000 mm - OD 20(22) mm - tube/elbow material 1.4301 or 1.4541 Tip shape: standard, narrowed, pitted (see Appendix - Tip shapes) Process pressure: YA protection tube process pressure (see Accessories - Protection tubes) Sheath material: 1.4301(M1), 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362 (M15), or bare sensor Wire material: Cu, Ni, or Ag Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance)

d [mm]

M1, M3, M4, M6, M6S, M8, M9, M11, M13, M14

6, 8, 10

M12

6, 8

M20

6

* Please contact COMECO! ** Order transmitter separately!!!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Protection Tube Material

20...25

60...100

Spring-loaded adapter: (mounted between protection tube and elbow)


temperature probes

Ordering code

TS - G0.G1G2.G3.G4.G6.G7.G9.G10.G11.G12.G13.G14 - #1.#2

Code Feature or option

Code values

Base model variant

LD - standard (w/ terminal block), OLD - prepared for in-head transmitter (w/o terminal block)

G0

Protection head

B - type "B", MA - type "MA", MB - type "MB", G - IP65, type "G", N - type "N", D - type "D", DW - windowed, type "DW", DH - w/ high cap, type "DH", DHW - windowed, type "DHW", E - IP65, type "E", ES - stainless-steel, type "ES", EG - IP68 ATEX-approved, type "EG", EGS - IP66 ATEX-approved, type "EGS", EGW - windowed ATEX-approved, type "EGW", EX - explosion-proof instrument housing (specify!)

G1

Number of RTD sensors

1, 2, or 3 (5)

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100

G3

Temperature range

T1 - -50…400 °C, T2 - -200…600 °C (Ni or Ag wires only!), T4 - 0…800 °C (Ag wires only!), T9 - -50…200 °C, T11 - -50…600 °C (Ni or Ag wires only!)

G4

Diameter 'd' [mm] (must fit the protection tube ID)

X (bare sensor), 6, 8, 10

G6

Probe length 'n' [mm]

100…1000

G7

Probe length 'm1' [mm]

100…1000

G9

Mounting connection (must fit the protection tube thread)

Q4 - G1/2", Q6 - G3/4", U4 - G1/2-F", U6 - G3/4-F"

G10

Sheath material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404, M15 - 1.4362

G11

Accuracy class (1)

A - 'A', B - 'B', C - '2xB'

G12

Number of wires

2, 3, 4 (5)

(1)

G13

Wire material

G14

Tip shape

CU - copper, NI - nickel, AG - silver X - standard closed, N - narrowed, P - pitted (2)

#1

Options

X - none, OV - vibration proof (MgO or Silicone filled, secured screws), OA - spring-loaded adapter (3), OP - electrochemically polished sheath surface

#2

Local indicator

X - none, A - local indicator mounted (4)

(1)

Only for Pt sensors! Only for non-explosion-proof RTDs! Not available for bare sensor! (4) With windowed head only! See indicator datasheets and order separately! (5) Contact COMECO! (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes ANGLED T/C PROBE WITH PROTECTION HEAD FOR PROTECTION TUBE ASSEMBLY

LDx (TSLDx)

(FOR IN-HEAD TRANSMITTER)** OLDx (TSOLDx) Holding tube - stainless steel 1.4301 or 1.4404 Protection tube - metal (see Accessories - Protection tubes) Head - aluminum, stainless steel, or plastic (see Appendix - Protection heads)

DIMENSIONS SENSITIVE ELEMENT

TEMPERATURE RANGE

wire ø [mm]

d [mm]

wires

Regular Thermocouple Design 8

1

10

1.5

bare

1, 1.5, 3

1 x J; 2 x J 0...800 °C

T4 1 x L; 2 x L

1 x K; 2 x K

1 x E; 2 x E

1 x S; 2 x S 1 x R; 2 x R

T3 T16 T6*

0...850 °C 0...1100 °C 0...1150 °C

T3 T13

0...850 °C 0...1000 °C

T16 T6* T21

0...1100 °C 0...1150 °C 0...1300 °C

10

1.5

bare

1.2, 3.2

8

1

10

1.5

bare

1, 1.5, 3

8

1

10

1.5

bare

1, 1.5, 3

8, 10, or bare

0.35, 0.5

2; 2x2

2; 2x2

2; 2x2

2; 2x2

2; 2x2

MI Thermocouple Design 1xJ 2xJ 1xK 1 x N; 1 x E 2xK 2 x N, 2 x E

T4

0...800 °C

3, 4.5, 6, 8

T3 T16 T6* T6*

0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C

3, 4.5, 6, 8, 10

2 2x2 2 2x2

Protection head: B, MA, MB, G, N, Dx, Ex, EX (see Appendix - Protection heads) Process connection (must fit the YA connection 'G'): G1/2"(Q4), G3/4"(Q6), male or female (see Accessories - Protection tubes) Insertion length (must fit the YA length 'L'): n = 100…1000 mm Holding tube: - m1 = 100…1000 mm - OD 20(22) mm - tube/elbow material 1.4301 or 1.4541 Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip shapes)

Protection Tube Material

Sheathed T/C max. d [mm]

Bare T/C max. ø [mm]

M11, M14

10

4 x ø3

M3, M4, M6, M6S, M8, M9

10

2 x ø3

Sheath material: 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362 (M15) MI sheath material: 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4876(M7), 2.4816(M8), Nicrobell® (M10) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)

* Please contact COMECO! ** Order transmitter separately!!!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

20...25

60...100

Spring-loaded adapter: (mounted between protection tube and elbow)

COMECO reserves the right of changing specifications without prior notice!

Process pressure: YA protection tube process pressure (see Accessories - Protection tubes)


temperature probes

Ordering code

TS - G0.G1G2.G3.G4.G6.G7.G9.G10.G11.G14 - #1.#2

Code Feature or option

Code values

Base model variant

LD - standard (w/ terminal block), OLD - prepared for in-head transmitter (w/o terminal block)

G0

Protection head

B - type "B", MA - type "MA", MB - type "MB", G - IP65, type "G", N - type "N", D - type "D", DW - windowed, type "DW", DH - w/ high cap, type "DH", DHW - windowed, type "DHW", E - IP65, type "E", ES - stainless-steel, type "ES", EG - IP68 ATEX-approved, type "EG", EGS - IP66 ATEX-approved, type "EGS", EGW - windowed ATEX-approved, type "EGW", EX - explosion-proof instrument housing (specify!)

G1

Number of thermocouples

1 or 2

G2

Thermocouple

J - type "J", K - type "K", N - type "N", E - type "E", L - type "L", S - type "S", R - type "R"

G3

Temperature range

T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (4), T13 - 0…1000 °C, T16 - 0…1100 °C, T21 - 0…1300 °C

G4

Diameter 'd' [mm] (must fit the protection tube ID)

G6

Probe length 'n' [mm]

100…1000

G7

Probe length 'm1' [mm]

100…1000

G9

Mounting connection (must fit the protection tube thread)

Q4 - G1/2", Q6 - G3/4", U4 - G1/2-F", U6 - G3/4-F"

G10

Sheath material

regular T/C

X (bare thermocouple), 8, 10

MI T/C

3, 4.5, 6, 8, 10

regular T/C

M2 - 1.4541, M3 - 1.4571, M4 - 1.4762, M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4404, M15 - 1.4362

MI T/C

M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®

G11

Accuracy class

1 - '1' (4), 2 - '2'

G14

Tip shape (hot junction)

X - standard (isolated from sheath), G - grounded, E - exposed hot junction (1), O - open-tube design (1)

#1

Options

X - none, OV - vibration proof (spring-type terminals (4), secured screws), OA - spring-loaded adapter (2), OP - electrochemically polished sheath surface

#2

Local indicator

X - none, A - local indicator mounted (3)

(1)

Only for non explosion-proof thermocouples! Not available for bare thermocouple! (3) With windowed head only! See indicator datasheets and order separately! (4) Contact COMECO!

COMECO reserves the right of changing specifications without prior notice!

(2)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

(MI) RTD PROBE WITH DETACHABLE CONNECTOR

TSKx

Sheath - stainless steel (see Appendix - Sheath materials) Connector - IP65/68 (see Appendix - Sensor connectors)

SENSITIVE ELEMENT

DIMENSIONS

TEMPERATURE RANGE

n [mm]

d [mm]

wires

Regular Design

DESIGN WITHOUT EXTENSION (TSK) 1 x Pt (RB,RD,RF,RG) 2 x Pt (RB,RD,RF,RG) 3 x Pt * (RB,RD,RF,RG)

T9 T1 T24 T11 T2 T4 T22

1 x Cu (RH, RK) -50...200 °C

T9 2 x Cu (RH, RK)

-50...100 °C

T12

2 x PTC (RP, RQ)

2, 3*

5

2, 3

50…1500

6

2, 3, 4*

50…3000

8, 10, 12, 14

2, 3, 4

50…3000

6*, 8, 10, 12, 14

2x2(3)*

50…3000

8, 10, 12, 14

3x2

50…1500

6

50…3000

8, 10, 12, 14

50…3000

EXTENDED DESIGN WITH WELDED CONNECTION (TSK1) 1 x PTC (RP, RQ)

4

50…500

-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C

2, 3, 4*

8, 10

2x2

12, 14

2x2(3)*

50…1500

6

50…3000

8, 10, 12, 14

50…3000

8, 10, 12, 14

2, 3 2x2

MI Design 1 x Pt (RB,RD,RF,RG)

2 x Pt (RB,RD,RF,RG)

EXTENDED DESIGN WITH MOVABLE CONNECTION (TSK2)

T9 T1 T24 T11 T2 T4 T22

-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C

3*

2, 3*

4.5

2, 3*

6

2, 3, 4*

8

2, 3, 4

6, 8

2x2, 2x3*

50...50000

50...50000

Detachable wiring connector: C1, C7, C8 (see Appendix - Connectors) Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1

DESIGN WITH ADJUSTABLE CONNECTION (TSK3)

Extension length: m = 0...1500 mm Probe diameter 'd' Ext. length 'm' up to 50 mm 50...150 mm 150...500 mm 500+ mm

3, 4 mm

4.5...6 mm

8 mm

10 mm

10+ mm

8 8 10 14

d 8 10 14

d d 10 14

d d d 14

d d d d

Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes) Process pressure:

DESIGN WITH GLAND-TYPE CONNECTION (TSK4)

Probe design Max. pressure *

TSK, TSK1

TSK2

TSK4

TSK3

25 bar

16 bar

6 bar

0 bar

Sheath material: 1.4301(M1), 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362(M15) Wire material: Cu, Ni, or Ag Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) * Please contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Extension diameter: (for TSK1 and TSK2 only, [mm])


temperature probes

Ordering code

TSK(1,2,3,4) - (MI -) G1G2.G3.G4.G6.G7.G9'9".G10.G11.G12.G13.G14.G15 - #1

Code Feature or option

Code values

G1

Number of RTD sensors (1)

1, 2, or 3 (10)

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP - PTC 1k, RQ - PTC 2k

G3

Temperature range

T1 - -50…400 °C, T2 - -200…600 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C, T22 - -200…200 °C, T24 - -50…500 °C

G4

Diameter 'd' [mm]

G6

Probe length 'n' [mm] (2)

50…50000 (see table overleaf)

G7

Probe length 'm' [mm] (3)

0…1500

G9'

Mounting connection

X - no mounting appliances (4), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)

G9"

Compression fitting ferrule (5)

BR - brass, GR - graphite, SS - stainless steel, TF - Teflon®

G10

Sheath material (wetted parts)

G11

Accuracy class

X - none (6), A - 'A', B - 'B', C - '2xB'

G12

Number of wires

2, 3, 4 (10)

G13

Wire material (7)

CU - copper (8), NI - nickel, AG - silver (9)

G14

Tip shape

X - standard closed, N - narrowed (9), P - pitted (9)

G15

Wiring connector

C1 - 4-pin connector M12 (IP68), C7 - DIN 43650 4-pin connector (IP65), C8 - DIN 43651 6-pin connector (IP65)

#1

Options

X - none, OV - vibration proof (MgO or Silicone filled) (9), OP - electrochemically polished wetted parts (9)

regular design

4, 5, 6, 8, 10, 12, 14

MI design

3 (10), 4.5, 6, 8

regular design

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404), M15 - 1.4362

MI design

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404)

(1)

The total number of wires must comply with the selected wiring connector! 'n+m' for TSK3 and TSK4! (3) Only for TSK1 and TSK2! (4) Only for TSK! (5) Only for TSK4! (6) For non-Pt sensors (7) Only for Pt sensors! (8) Not applicable to non-MI (regular) RTDs for above 500 °C! (9) Only for non-MI (regular) design! (10) Contact COMECO!

COMECO reserves the right of changing specifications without prior notice!

(2)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes

OUTDOOR RTD PROBE WITH ANCHOR BOLT

TSCA SENSITIVE ELEMENT

Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum (see Appendix - Protection heads)

TEMPERATURE RANGE

DIMENSIONS d [mm]

wires

4

2

5

2, 3*

6

2, 3, 4*

1 x Pt (RB,RD,RF,RG)

T12

-50...100 °C

2 x Pt (RB,RD,RF,RG)

T12

-50...100 °C

6

2x2

1 x Cu (RH, RK)

T12

-50...100 °C

5, 6

2, 3

2 x Cu (RH)

T12

-50...100 °C

6

2x2

1 x PTC (RP, RQ)

T12

-50...100 °C

6

2

Protection head: MA, MB (see Appendix - Protection Heads) Mounting accessories: Zn-plated anchor bolt (ø8) w/ rubber sealed clamp (ø20) Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes)

Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) n = 40 … 180 mm

Filling: silicone grease (except pitted version) Protection tube: PVC, ø20x2 Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance)

* Please contact COMECO!

TSCA - G0.G1G2.G4.G6.G10.G11.G12.G14

Code Feature or option

Code values

G0

Protection head

MA - type "MA", MB - type "MB"

G1

Number of RTD sensors

1 or 2

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP -PTC 1k, RQ - PTC 2k

G4

Diameter 'd' [mm]

4, 5, 6

G6

Anchor bolt length 'n' [mm]

40…180 (step 10 mm)

G10

Sheath material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

G11

Accuracy class (1)

A - 'A', B - 'B', C - '2xB'

G12

Number of wires

2, 3, 4 (2)

G14

Tip shape

X - standard closed, N - narrowed, P - pitted

(1) (2)

Only for Pt sensors! Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code


temperature probes

RTD PROBE FOR MEAT CUTTING MACHINES

TSCC

Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum or stainless steel (see Appendix - Protection heads)

SENSITIVE ELEMENT

TEMPERATURE RANGE

WIRES

1 x Pt (RB,RD,RF,RG)

T9

-50...200 째C

2, 3, 4

2 x Pt (RB,RD,RF,RG)

T9

-50...200 째C

2x2, 2x3*

1 x Cu (RH, RK)

T9

-50...200 째C

2, 3, 4

2 x Cu (RH)

T9

-50...200 째C

2x2, 2x3*

Protection head: B, MA, MB, D, G, ES (see Appendix - Protection Heads) Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Filling: silicone grease Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) * Please contact COMECO!

Ordering code

TSCC - G0.G1G2.G10.G11.G12 - #1

Code Feature or option

Code values

G0

Protection head

B - type "B", MA - type "MA", MB - type "MB", D - type "D", G - type "G", ES - type "ES"

G1

Number of RTD sensors

1 or 2

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100

G10

Sheath material (1)

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

G11

Accuracy class

G12

Number of wires

2, 3, 4 (2)

#1

Options

X - none, OP - electrochemically polished sheath surface

(2)

Only for Pt sensors! Contact COMECO!

COMECO reserves the right of changing specifications without prior notice!

(1)

A - 'A', B - 'B', C - '2xB'

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes Outdoor RTD Probe (Transmitter) TS(O)P ♦ ♦ ♦ ♦ ♦ ♦

Low cost Ptx sensitive element 2-wire 4…20 mA output available IP66 protection class Robust aluminum enclosure Ready to use - no adjustments

The outdoor temperature probes TSP and TSOP measure temperature by means of a Ptx sensitive element mounted in a thin stainless steel stem for fast response. The TSOP model, in addition, converts the measured temperature into standard 4...20 mA 2-wire signal. Both models are enclosed in a freely mountable robust aluminum enclosure with IP66 protection class and are equipped with a PG7 cable gland for stable and protected electrical decoupling. Five different temperature measurement ranges from -50 °C and up to 100 °C as well as customer specified ranges are available. Thanks to their simplicity, small size, and affordable price, TSP and TSOP are applicable for various outdoor applications, environment temperature control, climatic temperature measurement, etc.

Technical specifications Input

Power supply

Incorporated RTD Measurement range

Pt100 or Pt1000 (w=1.385) -50...50 °C; 0...50 °C; -20...60 °C; 0...100 °C (1); -50...100 °C (1) minimum span 50 °C (transmitter only)

Range on request

Output Signal type Linearity proportional to Output at sensor burnout Output at sensor shorted

Accuracy Electronic measurement error RTD measurement error Non-linearity Self-heating error Temperature drift (2)

Operating conditions Ambient temperature Ambient humidity EM compatibility

-30...65 °C 5...95 %RH according to EN 61326

Design and materials Stem diameter Stem length Sensor sheath Housing material Wiring Mounting Protection class

4 mm 20...60 mm

5 mm 60...200 mm stainless steel aluminum PG7 metal cable gland free IP66

Not available for TSOP Which is greater

Ordering code

TS(O)P - G2.G3.G6.G11 - #1

Code Feature or option

(3)

(transmitter only) 0.2% from span or 0.2 °C (2) according to accuracy class within measurement error 0.02%/mA at 24 V 0.02% from span for 1 °C

10...32 VDC 1 Vp-p at 50 Hz 750 Ω at 24V/20mA

Code values

G2

Sensor (3)

RD - Pt100, RG - Pt1000

G3

Temperature range

T10 - -20...60 °C, T17 - -50...50 °C, T18 - 0...50 °C, T19 - 0...100 °C (1), T12 - -50...100 °C (1), TZ - other (specify, ΔT ≥ 50 °C)

G6

Stem length 'n' [mm]

20…200 (see table above)

G11

Accuracy class

A - 'A', B - 'B', C - '2xB'

#1

Options

X - none, OP - electrochemically polished sheath surface

Do not code for TSOP

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(1)

4...20 mA, 2-wire measured value 32 mA 0.2 mA

Loop voltage Admissible variations Maximum line load


temperature probes Indoor RTD Probe (Transmitter) TS(O)R ♦ ♦ ♦ ♦ ♦ ♦

Low-cost variant for budget applications Ptx sensitive element 2-wire 4…20 mA output available Easy & Fast connection plug Ready to use - no adjustments DIN-rail accessory available

The indoor temperature probes TSR, TSR1, TSOR, and TSOR1 perform fast temperature measurement by means of a Ptx sensitive element mounted in a copper sheath or inside the housing. The TSOR and TSOR1 variants, in addition, convert the measured temperature into standard 4...20 mA 2-wire signal. All variants are enclosed in a freely mountable small plastic box that may also be mounted on a DIN rail when an optional mounting clamp is installed. TSR and TSOR are also equipped with a 3-pin plug-in terminal that allow fast and easy electrical decoupling. Five different temperature measurement ranges from -50 °C and up to 100 °C as well as customer specified ranges are available. Thanks to their simplicity, small size, and affordable price, TSR, TSR1, TSOR, and TSOR1 are applicable for various indoor applications, room temperature control, control board temperature measurement, etc.

Technical specifications Input

Power supply

Incorporated RTD Measurement range Range on request

Output Signal type Linearity proportional to Output at sensor burnout Output at sensor shorted

Pt100 or Pt1000 (w=1.385) -50...50 °C; 0...50 °C; -20...60 °C; 0...100 °C (1); -50...100 °C (1) minimum span 50 °C (transmitter only) 4...20 mA, 2-wire measured value 32 mA 0.2 mA

Accuracy

(transmitter only)

Electronic measurement error RTD measurement error Non-linearity Self-heating error Temperature drift (2) (3)

Ambient temperature Ambient humidity Directives

Design and materials Sensor sheath Housing material Wiring Mounting Dimensions Weight Protection class

-30...65 °C 5...85 %RH CE (2004/108/EC), LVD (2006/95/EC) TS(O)R TS(O)R1 copper none (hidden sensor) plastic plastic plug-in terminal hidden terminal free (3) free (3) 40x75x26 mm 40x75x26 mm (w/o terminal) max. 30 g max. 45 g IP20 IP44 (excl. terminal)

Not available for TSOR and TSOR1. Which is greater DIN-rail mounting accessory is also available (see 'Accessories')

Ordering code

TS - G2.G3.G11

Code Feature or option

Code values

Variant

R - RTD probe, R1 - low-cost RTD probe, OR - temperature transmitter, OR1 - low-cost temperature transmitter

G2

Sensor (4)

RD - Pt100, RG - Pt1000

G3

Temperature range

T10 - -20...60 °C, T17 - -50...50 °C, T18 - 0...50 °C, T19 - 0...100 °C (1), T12 - -50...100 °C (1), TZ - other (specify, ΔT ≥ 50 °C)

G11

Accuracy class

A - 'A', B - 'B', C - '2xB'

(4)

Operating conditions

Do not code for TSOR and TSOR1.

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(1)

0.2% from span or 0.2 °C (2) according to accuracy class within measurement error 0.02%/mA at 24 V 0.02% from span for 1 °C

10...32 VDC 1 Vp-p at 50 Hz 750 Ω at 24V/20mA

Loop voltage Admissible variations Maximum line load


temperature probes RTD Probe with Current Output TSOK ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

Pt100 or Pt1000 sensitive element 2-wire 4…20 mA output Easy & Fast connection plug M12 Vibration-proof design Small dimensions Extended design for higher temperature available High protection class - IP65 Local indicator available

TSOK measures temperature by the means of a Ptx sensitive element and converts it into standard 4...20 mA 2-wire current signal. This transmitter has a robust vibration-proof stainless steel sheath with IP65 protection class, and is equipped with a DIN 43650 connector that allows fast and easy electrical decoupling. The probe interior is filled with special compound, which protects the electronics from the harsh ambient influences. Eight different temperature measurement ranges from -50 °C and up to 400 °C as well as customer specified ranges are available. Various stem diameters and lengths as well as stainless steel types are also available. A local loop-powered indicator TI200 can be optionally mounted between the sheath top and the connector. Thanks to its small size and robust design, TSOK is applicable for cars, rail vehicles, construction machines, and other industrial equipment.

Technical specifications Input

Power supply

Input (RTD) type Measurement range

Pt100 or Pt1000 (w=1.385), class B -50...50 °C; -20...60 °C; 0...50 °C; 0...100 °C; -50...100 °C; 0...150 °C; 0...200 °C; 0...300 °C (1); 0...400 °C (1,5) minimum span 50 °C

Range on request

Output Signal type Linearity proportional to Output at sensor burnout Output at sensor shorted

4...20 mA, 2-wire measured value 32 mA 0.2 mA

Accuracy 0.2% from span or 0.2 °C (2) within measurement error 0.01% from span for 1 °C

Measurement error Non-linearity Temperature drift

(2)

max. 25 bar -40...85 °C 0...98 %RH according to EN 61000, EN 61010

Design and materials Sensor sheath Wiring Mounting thread Stem diameter Stem length Extension length (1) Protection class

stainless steel 4-pin detachable connector DIN 43650 M16, M18, M20, 3/8”, 1/2”, or other 6 or 8 mm 20...300 mm 50...100 mm IP65

Code values

Variant

K - short-design, K1 - extended-design

G3

Temperature range

T17 - -50...50 °C, T10 - -20...60 °C, T18 - 0...50 °C, T19 - 0...100 °C, T12 - -50...100 °C, T20 - 0...150 °C, T7 - 0...200 °C, T23 - 0...300 °C (1), T8 - 0...400 °C (1,5), TZ - other (specify, ΔT ≥ 50 °C)

G4

Stem diameter 'd' [mm]

6, 8

G6

Stem length 'n' [mm]

20 (3)…300 (step 5 mm)

G7

Extension length 'm' [mm] (1)

G9

(5)

Medium pressure Ambient temperature Ambient humidity EM compatibility and safety

TSO - G3.G4.G6.G7.G9.G10.G14 - #1.#2

Code Feature or option

(4)

Operating conditions

Only for the extended-design variant! Which is greater

Ordering code

(3)

10...32 VDC 1 Vp-p at 50 Hz 750 Ω at 24V/20mA

Mounting thread

50…100 (step 5 mm)

cylindrical (15 mm length)

Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", QZ - other (specify!)

tapered (standard length)

Q9 - 3/8" NPT, Q10 - 1/2" NPT, QZ - other (specify!)

G10

Sheath material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

G14

Tip shape

X - standard closed, N - narrowed

#1

Options

X - none, OP - electrochemically polished sheath surface

#2

Local indicator TI200

X - none, A - local indicator TI200 (4)

Minimum thread length + 5 mm! See TI200 specifications and order separately! Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(1)

Loop voltage Admissible variations Maximum line load


temperature probes Programmable RTD Probe with Current Output TSOJ ♦ ♦ ♦ ♦ ♦ ♦ ♦

Programmable conversion range 2-wire 4…20 mA output Easy & Fast connection plug Straight or angled cable connector Small dimensions Vibration-proof design High protection class - IP65

TSOJ measures temperature within the -50...200 °C range via a Pt100 sensitive element and converts it into standard 4...20 mA 2-wire signal. The configuration software "TraCon" enables programming of the measurement range and output direction as well as other parameters. The probe has a robust vibration-proof stainless steel sheath with IP65 protection class, and its interior is filled with special compound, which protects the electronics from the harsh ambient influences. TSOJ is equipped with a detachable connector that allows fast and easy electrical decoupling. Various stem diameters and lengths as well as stainless steel types are available. Thanks to its robust design and flexible programming, the TSOJ probe is a fast and convenient solution to varying problems involving temperature measurement and conversion in industrial environments.

Technical specifications Input Input (RTD) type Measurement range Minimum programmable span

Output Signal type Maximum load Sensor failure reaction

(programmable) Pt100 (w=1.385) min. -50...max. 200 °C, programmable 50 °C (programmable) 4...20 mA or 20...4 mA, 2-wire 800 Ω at 24V/20mA < 3.9 or > 20.2 mA, programmable

Accuracy

Power supply 10...32 VDC 1 Vp-p at 50 Hz

Loop voltage Admissible variations

RS232, requiring special cable (2) "TraCon", free

Operating conditions Medium pressure Ambient temperature Ambient humidity EM compatibility

max. 25 bar -20...70 °C 0...95 %RH, non-condensing according to EN 61326

Case material Wiring Dimensions Mounting thread Stem diameter Stem length Protection class

stainless steel 4-pin detachable connector M12 or DIN 43650 (incl. female part) ø30x max. 66 mm (w/o stem and connector) M16, M18, M20, 3/8”, 1/2”, or other 6 or 8 mm 20...300 mm, step 5 mm IP65

Which is greater Ordered separately

Ordering code

TSOJ - G4.G6.G9.G10.G11.G14.G15 - #1

Code Feature or option

Code values

G4

Stem diameter 'd' [mm]

6, 8

G6

Stem length 'n' [mm]

20 (3)…300 (step 5 mm)

G9

Mounting thread

cylindrical (15 mm length)

Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", QZ - other (specify!)

tapered (standard length)

Q9 - 3/8" NPT, Q10 - 1/2" NPT, QZ - other (specify!)

G10

Sheath material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404

G11

Accuracy class (4)

A - 'A', B - 'B'

G14

Tip shape

X - standard closed, N - narrowed

G15

Wiring connector

C1A - angled connector M12, C1S - straight connector M12, C7 - DIN 43650 connector

#1

Options

X - none, OP - electrochemically polished sheath surface

(3)

Minimum thread length + 5 mm! (4) Of the built-in Pt100 sensor

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(2)

Interface type Configuration software

Design and materials 0.2% from span or 0.2 °C (1) according to the accuracy class within measurement error 0.01% from span for 1 °C

Measurement error RTD error Non-linearity Temperature drift

(1)

Serial interface


temperature probes

ROOM TEMPERATURE PROBE

TSUM

Case - plastic (ABS)

SENSITIVE ELEMENT

TEMPERATURE RANGE

1 x Pt (RB,RD,RF,RG)

T10

-10...60 °C

1 x Cu (RH, RK)

T10

-10...60 °C

SPECIFIC FEATURES

Room temperature measured value may be adjusted (increased or decreased) by the number pointed on the scale. The following designs exist according to maximum adjustment value: - up to ± 4 °C * - up to ± 8 °C * - up to ± 12 °C *

* Specify when ordering!

Ordering code

TSUM - G2

Code Feature or option Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100

COMECO reserves the right of changing specifications without prior notice!

G2

Code values

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


transmitters Infrared Temperature Transmitter TRU ♦ ♦ ♦ ♦ ♦ ♦ ♦

Low-temperature remote measurement Object temperature range from -10 to 150 °C Field of view 7.3 ° Linear current or voltage output signal Serial interface available Local programmable indicator available IP66 protection class

The TRU temperature transmitter's operation is based on the principle of sensing infrared radiation, emitted from a heated object, situated at a certain distance from the sensor, at a 7.3 ° conical angle. The sensitive thermopile element comprises of a multitude of thermocouples connected in series and allows measurement of the object surface temperature within the -10…150 °C range. The incorporated electronics converts the sensor output into a standard current or voltage signal suitable for further transmission and processing. Moreover, the transmitter may be equipped with programmable local LED indicator as well as with RS232 serial interface for data transmitting. By the means of specialized software, the information about the object's temperature may be viewed, stored, and printed from a PC. TRU is enclosed in a robust plastic box with connector, both with IP66, and is designed to be either freely mounted or mounted on DIN rail via special brackets. The TRU transmitter is very suitable for these special applications that require non-contact low-temperature-object measurement.

Technical specifications Input

Interface

Input type Material emission coefficient Object temperature range Calibrating distance Calibrating spot Field of view

object infrared emission 5...15 μm ≥ 0.85 min. -10...max. 150 °C 5 cm 3.5 cm 7.3 °

Analog output Output signal Output function Accuracy Temperature drift Maximum output load Output overload reaction

0(4)...20 mA or 0...10 V input signal info retransmission 2% from span 0.02% from span for 1 °C 750 Ω at 24V/20 mA display message

Local indicator (option) 3 LED indicators, 14 mm 1 °C 2 membrane keys

Digital display Display resolution Keyboard

Power supply Supply voltage Admissible variations Consumption

15...32 VDC 4 Vp-p at 50 Hz max. 120 mA

Operating conditions Ambient temperature Storage temperature

-10...65 °C -20...85 °C

Design and materials Case material Mounting Wiring Dimensions Weight Protection class

ABS/PC plastic free (1) 4-pin М12 connector 80x92x65 mm max. 250 g IP66

Radial, axial, and DIN-rail mounting accessories for 80x80x60 mm box can be ordered separately (see 'Accessories').

Ordering code

TRU - G9.G11 - #1

Code Feature or option

(2)

RS232 data transmission

Code values

G9

Serial interface

X - none, A - RS232

G11

Analog output

X - none (2), E - 0…20 mA, F - 4…20 mA, K - 0…10 V, Z - other on request

#1

Local indicator (2)

X - none, A - local indicator mounted

When no output is requested, local indicator must be ordered!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(1)

Interface type Function


temperature probes ATEX (MI) RTD PROBE - FOR IN-HEAD TRANSMITTER **

TSCx - EX TSOCx - EX

II 2 G Ex d IIC T6 Gb -20°C≤Ta≤+65°C II 2 D Ex tb IIIC T80 °C Db IP65 EC-type Certificate No. MP 08 ATEX 0002

DIMENSIONS SENSITIVE ELEMENT

TEMPERATURE RANGE

n [mm]

d [mm]

wires

Regular Design

DESIGN WITHOUT EXTENSION (TS(O)C) 1 x Pt (RB,RD,RF,RG)

2(3) x Pt (RB,RD,RF,RG)

for n < 150 mm, contact COMECO!

EXTENDED DESIGN WITH WELDED CONNECTION (TS(O)C1)

T9 T1 T24 T11 T2 T4 T22

-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C

1 x Cu (RH, RK)

T9

-50...200 °C

2 x Cu (RH, RK)

T9

-50...200 °C

T12

-50...100 °C

1 x PTC (RP, RQ)

2 x Pt (RB,RD,RF,RG)

EXTENDED DESIGN WITH MOVABLE CONNECTION (TS(O)C2)

T9 T1 T24 T11 T2 T4 T22

4 5

2, 3*

50…1500

6

2, 3, 4*

50…3000 8, 10, 12, 14, 16, 20

2, 3, 4

6*, 8, 10

2x2(3)*

12, 14, 16, 20

2x2(3), 3x2

50…3000 50…1500

6

-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C

2, 3, 4*

50…3000 8, 10, 12, 14, 16, 20 8, 10 12, 14, 16, 20 6 8, 10, 12, 14 8, 10, 12, 14

2x2 2x2(3)*

50...50000

3* 4.5 6 8

2, 3* 2, 3* 2, 3, 4* 2, 3, 4

50...50000

6, 8

2x2, 2x3*

50…3000

50…1500 50…3000 50…3000 MI Design

2 x PTC (RP, RQ)

1 x Pt (RB,RD,RF,RG)

50…500

2, 3 2x2

Protection head: EG(SS), EGS, EGW(SS), EX8(SS), EX8W(SS), EX10(SS), EX10W(SS), EX8WD, EX10WD (see Appendix - Protection Heads) Electrical entry: - cable gland(s): SS or brass, cemented, ID 7.5 mm - threaded head conduit(s) Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1

DESIGN WITH ADJUSTABLE CONNECTION (TS(O)C3)

Extension length: m = 0…1500 mm

Probe diameter 'd' Ext. length 'm' up to 50 mm 50...150 mm 150...500 mm 500+ mm

3, 4 mm

4.5...6 mm

8 mm

10 mm

10+ mm

8 8 10 14

d 8 10 14

d d 10 14

d d d 14

d d d d

Tip shape: standard or narrowed (see Appendix - Tip Shapes) Process pressure:

DESIGN WITH GLAND-TYPE CONNECTION (TS(O)C4)

Probe design Max. pressure *

TS(O)C, TS(O)C1 25 bar

TS(O)C2 16 bar

TS(O)C4 6 bar

TS(O)C3 0 bar

Sheath material: 1.4301(M1), 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362(M15) Wire material: Cu, Ni, or Ag Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) * Please contact COMECO! ** Order transmitter separately!!!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Extension diameter: (for TS(O)C1 and TS(O)C2 only, [mm])


temperature probes

Ordering code

TS (1,2,3,4) - (MI -) G0'n0".G1G2.G3.G4.G6.G7.G9'9".G10.G11.G12.G13.G14 - #1.#2 - EX

Code Feature or option

Code values

Base model variant

C - standard (w/ terminal block), OC - prepared for in-head transmitter (w/o terminal block)

G0'

Protection head

EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", EX8 - type "EX8", EX8SS - type "EX8SS", EX8W - type "EX8W", EX8WSS - type "EX8WSS", EX10 - type "EX10", EX10SS - type "EX10SS", EX10W - type "EX10W", EX10WSS - type "EX10WSS", EX8WD - type "EX8WD", EX10WD - type "EX10WD"

G0"

Electrical entry ('n' - number of entries (12))

G - gland, U2 - M20x1.5, U4 - G1/2", U6 - G3/4", U10 - 1/2" NPT, U11 - 3/4" NPT

G1

Number of RTD sensors

1, 2, or 3 (11)

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP - PTC 1k, RQ - PTC 2k

G3

Temperature range

T1 - -50…400 °C, T2 - -200…600 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C, T22 - -200…200 °C, T24 - -50…500 °C

G4

Diameter 'd' [mm]

G6 G7

Probe length 'n' [mm]

regular design

4, 5, 6, 8, 10, 12, 14, 16, 20

MI design

3 (11), 4.5, 6, 8

(1)

Probe length 'm' [mm]

50…50000 (see table overleaf)

(2)

0…1500 X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)

G9'

Mounting connection

G9"

Compression fitting ferrule (4) regular design

BR - brass, GR - graphite, SS - stainless steel, TF - Teflon® M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404), M15 - 1.4362 (11)

G10

Sheath material (wetted parts)

G11

Accuracy class

X - none (5), A - 'A', B - 'B', C - '2xB'

G12

Number of wires

2, 3, 4 (11)

(6)

MI design

M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404)

CU - copper (7), NI - nickel, AG - silver (8)

G13

Wire material

G14

Tip shape

X - standard closed, N - narrowed (8)

#1

Options

X - none, OV - vibration proof (spring terminals, MgO or Silicone filled, secured screws) (8), OT - thermal isolation (3), OP - electrochemically polished sheath surface (8)

#2

Incorporated devices

X - none, T - in-head transmitter (9), A - local indicator (10)

(1)

'n+m' for TS(O)C3 and TS(O)C4! Only for TS(O)C1 and TS(O)C2! Only for TS(O)C! (4) Only for TS(O)C4! (5) For non-Pt sensors (6) Only for Pt sensors! (7) Not applicable to non-MI (regular) RTDs for above 500 °C! (8) Only for non-MI (regular) design! (9) Only for variant 'OC'! See transmitter datasheets and order separately! (10) With windowed head only! See indicator datasheets and order separately! (11) Contact COMECO! (12) Applicable for the selected head type (see Appendix - Protection Heads) (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes ATEX (MI) T/C PROBE - FOR IN-HEAD TRANSMITTER **

TSCx - EX TSOCx - EX

II 2 G Ex d IIC T6 Gb -20°C≤Ta≤+65°C II 2 D Ex tb IIIC T80 °C Db IP65 EC-type Certificate No. MP 08 ATEX 0002

DIMENSIONS SENSITIVE ELEMENT

TEMPERATURE RANGE

1(2) x J 1(2) x L

T4

0...800 °C

1(2) x K

T3 T16 T6*

0...850 °C 0...1100 °C 0...1150 °C

1(2) x E

T3 T13

0...850 °C 0...1000 °C

50...1500

6

50...3000

8, 10, 12, 14, 16, 20, 22

2 (2x2)

1(2) x S 1(2) x R

T16 T6*

0...1100 °C 0...1150 °C

50...1500 50...3000

6 8, 10, 12, 14, 16, 20, 22

2 (2x2)

T4

0...800 °C

50...50000

3, 4.5, 6, 8, 10*

T8

0...400 °C

50...50000

3, 4.5, 6, 8, 10*

0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C

50...50000

3, 4.5, 6, 8, 10*

2

2xK 2 x N, 2 x E

T3 T16 T6* T6*

50...50000

3, 4.5, 6, 8, 10*

2x2

2xS 2xR

T16 T6*

0...1100 °C 0...1150 °C

50...10000

3, 4.5, 6

2x2

n [mm]

d [mm]

wires

50...1500 50...3000

6 8, 10, 12, 14, 16, 20, 22

2 (2x2)

50...1500

6

50...3000

8, 10, 12, 14, 16, 20, 22

Regular Design

DESIGN WITHOUT EXTENSION (TS(O)C)

for n < 150 mm, contact COMECO!

2 (2x2)

MI Design

EXTENDED DESIGN WITH WELDED CONNECTION (TS(O)C1)

1xJ 2xJ 1xT 2xT 1xK 1 x N, 1 x E

2 2x2 2 2x2

Protection head: EG(SS), EGS, EGW(SS), EX8(SS), EX8W(SS), EX10(SS), EX10W(SS), EX8WD, EX10WD (see Appendix - Protection Heads)

EXTENDED DESIGN WITH MOVABLE CONNECTION (TS(O)C2)

Electrical entry: - cable gland(s): SS or brass, cemented, ID 7.5 mm - threaded head conduit(s) Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Extension length: m = 0…1500 mm Extension diameter: (for TS(O)C1 and TS(O)C2 only, [mm]) Probe diameter 'd' Ext. length 'm' up to 50 mm 50...150 mm 150...500 mm 500+ mm

3 mm

4.5, 6 mm

8 mm

10 mm

10+ mm

6 8 10 14

d 8 10 14

d d 10 14

d d d 14

d d d d

Tip shape (hot junction design): standard (isolated) (see Appendix - Tip Shapes) Process pressure:

DESIGN WITH GLAND-TYPE CONNECTION (TS(O)C4)

Probe design Max. pressure *

TS(O)C, TS(O)C1 25 bar

TS(O)C2 16 bar

TS(O)C4 6 bar

TS(O)C3 0 bar

Sheath material: 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762/1.4749(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362(M15) MI sheath material: 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762/1.4749(M4), 1.4841(M5), 1.4876(M7), 2.4816(M8), Nicrobell®(M10) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) * Please contact COMECO! ** Order transmitter separately!!!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

DESIGN WITH ADJUSTABLE CONNECTION (TS(O)C3)


temperature probes

Ordering code TS (1,2,3,4) - (MI -) G0'n0".G1G2.G3.G4.G6.G7.G9'9".G10.G11 - #1.#2 - EX Code Feature or option

Code values

Base model variant

C - standard (w/ terminal block), OC - prepared for in-head transmitter (w/o terminal block)

G0'

Protection head

EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", EX8 - type "EX8", EX8SS - type "EX8SS", EX8W - type "EX8W", EX8WSS - type "EX8WSS", EX10 - type "EX10", EX10SS - type "EX10SS", EX10W - type "EX10W", EX10WSS - type "EX10WSS", EX8WD - type "EX8WD", EX10WD - type "EX10WD"

G0"

Electrical entry ('n' - number of entries (9))

G - gland, U2 - M20x1.5, U4 - G1/2", U6 - G3/4", U10 - 1/2" NPT, U11 - 3/4" NPT

G1

Number of thermocouples

1 or 2

G2

Thermocouple

G3

Temperature range

G4

Diameter 'd' [mm]

G6

Probe length 'n' [mm] (1)

G7

Probe length 'm' [mm]

regular design

E - type "E", J - type "J", K - type "K", L - type "L", R - type "R", S - type "S"

MI design

E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T" T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (8), T13 - 0…1000 °C, T16 - 0…1100 °C

regular design

6, 8, 10, 12, 14, 16, 20, 22

MI design

3, 4.5, 6, 8, 10 50…50000 (see table overleaf)

(2)

0…1500

G9'

Mounting connection

X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)

G9"

Compression fitting ferrule (4)

BR - brass, GR - graphite, SS - stainless steel, TF - Teflon®

G10

Sheath material (wetted parts)

regular design

M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4401 (1.4404), M15 - 1.4362

MI design

M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876, M8 - 2.4816, M9 - 1.4401 (1.4404), M10 - Nicrobell®

G11

Accuracy class

1 - '1' (8), 2 - '2'

#1

Options

X - none, OV - vibration proof (spring terminals (8), secured screws), OT - thermal isolation (3), OP - electrochemically polished sheath surface (5)

#2

Incorporated devices

X - none, T - in-head transmitter (6), A - local indicator (7)

(1)

'n+m' for TS(O)C3 and TS(O)C4! Only for TS(O)C1 and TS(O)C2! Only for TS(O)C! (4) Only for TS(O)C4! (5) Only for non-MI (regular) design! (6) Only for variant 'OC'! See transmitter datasheets and order separately! (7) With windowed head only! See indicator datasheets and order separately! (8) Contact COMECO! (9) Applicable for the selected head type (see Appendix - Protection Heads) (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes ATEX RTD PROBE WITH (MI) INSERT - FOR IN-HEAD TRANSMITTER ** II 2 G Ex d IIC T6 Gb -20°C≤Ta≤+65°C II 2 D Ex tb IIIC T80 °C Db IP65

TSCSx - EX TSOCSx - EX

DIMENSIONS SENSITIVE ELEMENT

TEMPERATURE RANGE

d insert [mm]

d [mm]

EC-type Certificate No. MP 08 ATEX 0002

wires

Regular Insert Design

DESIGN WITHOUT EXTENSION (TS(O)CS) 1 x Pt (RB,RD,RF,RG)

2 x Pt (RB,RD,RF,RG) for n < 150 mm, contact COMECO!

1 x Cu (RH, RK) 2 x Cu (RH, RK)

EXTENDED DESIGN WITH WELDED CONNECTION (TS(O)CS1) 1 x Pt (RB,RD,RF,RG)

2 x Pt (RB,RD,RF,RG)

T9 T1 T24 T11 T2 T4 T22

-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C -50...200 °C

T9

-50...200 °C

T9

T9 T1 T24 T11 T2 T4 T22

8

4, 5

2, 3*

9, 10, 12, 14, 16, 20

6

2, 3, 4*

12, 14, 16, 20

8

2, 3, 4

9, 10, 12, 14, 16, 20

6

2x2*

12, 14, 16, 20

8

2x2(3)*

9, 10, 12, 14, 16, 20

6

2, 3, 4*

12, 14, 16, 20

8

2, 3, 4

9, 10, 12, 14, 16, 20

6

2x2*

12, 14, 16, 20

8

2x2(3)*

3*

2, 3*

MI Insert Design 6, 8, 9, 10, 12, 14, 16, 20 8, 9, 10, 12, 14, 16, 20 9, 10, 12, 14, 16, 20

-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C

4.5

2, 3*

6

2, 3, 4* 2, 3, 4

12, 14, 16, 20

8

9, 10, 12, 14, 16, 20

6

2x2, 2x3*

12, 14, 16, 20

8

2x2, 2x3*

Protection head: EG(SS), EGS, EGW(SS), EX8(SS), EX8W(SS), EX10(SS), EX10W(SS), EX8WD, EX10WD (see Appendix - Protection Heads)

EXTENDED DESIGN WITH MOVABLE CONNECTION (TS(O)CS2)

Electrical entry: - cable gland(s): SS or brass, cemented, ID 7.5 mm - threaded head conduit(s) Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Extension length: m = 0…1500 mm Extension diameter: (for TS(O)CS1 and TS(O)CS2 only, [mm]) Probe diameter 'd' Ext. length 'm'

6 mm

8 mm

9, 10 mm

10+ mm

up to 50 mm

d

d

d

d

50...150 mm

8

d

d

d

150...500 mm

10

10

d

d

500+ mm

14

14

14

d

Tip shape: standard or narrowed (see Appendix - Tip Shapes) Process pressure: Probe design

DESIGN WITH GLAND-TYPE CONNECTION (TS(O)CS4)

Max. pressure *

TS(O)CS, TS(O)CS1 TS(O)CS2 25 bar

16 bar

TS(O)CS4

TS(O)CS3

6 bar

0 bar

Sheath material: 1.4301(M1), 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362(M15) Wire material: Cu, Ni, or Ag Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) * Please contact COMECO! ** Order transmitter separately!!!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

DESIGN WITH ADJUSTABLE CONNECTION (TS(O)CS3)


temperature probes

Ordering code

TS (1,2,3,4) - (MI -) G0'n0".G1G2.G3.G4.G6.G7.G9'9".G10.G11.G12.G13.G14 - #1.#2 - EX

Code Feature or option

Code values

Base model variant

CS - standard (w/ terminal block), OCS - prepared for in-head transmitter (w/o terminal block)

G0'

Protection head

EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", EX8 - type "EX8", EX8SS - type "EX8SS", EX8W - type "EX8W", EX8WSS - type "EX8WSS", EX10 - type "EX10", EX10SS - type "EX10SS", EX10W - type "EX10W", EX10WSS - type "EX10WSS", EX8WD - type "EX8WD", EX10WD - type "EX10WD"

G0"

Electrical entry ('n' - number of entries (13))

G - gland, U2 - M20x1.5, U4 - G1/2", U6 - G3/4", U10 - 1/2" NPT, U11 - 3/4" NPT

G1

Number of RTD sensors

1 or 2

G2

Sensor

RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100

G3

Temperature range

T1 - -50…400 °C, T2 - -200…600 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C, T22 - -200…200 °C, T24 - -50…500 °C

G4

Diameter 'd' / 'd insert' [mm]

G6 G7

Probe length 'n' [mm]

regular insert

8/4, 8/5, 9/6, 10/6, 12/6, 14/6, 12/8, 14/8, 16/6, 16/8, 20/6, 20/8

MI insert

6/3 (12), 8/4.5, 9/6, 10/6, 12/6, 14/6, 16/6, 16/8, 20/6, 20/8

(1)

Probe length 'm' [mm]

50…3000

(2)

0…1500 X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)

G9'

Mounting connection

G9"

Compression fitting ferrule (4)

BR - brass, SS - stainless steel, TF - Teflon®

regular insert

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404), M15 - 1.4362 (12)

MI insert

M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404)

G10

Sheath material (wetted parts and insert)

G11

Accuracy class

X - none (5), A - 'A', B - 'B', C - '2xB'

G12

Number of wires

2, 3, 4 (12)

(6)

CU - copper (7), NI - nickel, AG - silver (8)

G13

Wire material

G14

Tip shape

X - standard closed, N - narrowed (12)

#1

Options

X - none, OV - vibration proof (MgO or Silicone filled insert, secured screws) (8,9), OS - spring-loaded insert, OT - thermal isolation (3), OP - electrochemically polished wetted parts

#2

Incorporated devices

X - none, T - in-head transmitter (10), A - local indicator (11)

(1)

'n+m' for TS(O)CS3 and TS(O)CS4! Only for TS(O)CS1 and TS(O)CS2! Only for TS(O)CS! (4) Only for TS(O)CS4! (5) For non-Pt sensors (6) Only for Pt sensors! (7) Not applicable to non-MI (regular) RTD inserts for above 500 °C! (8) Only for non-MI (regular) inserts! (9) Requires 'OS' option! (10) Only for variant 'OCS'! See transmitter datasheets and order separately! (11) With windowed head only! See indicator datasheets and order separately! (12) Contact COMECO! (13) Applicable for the selected head type (see Appendix - Protection Heads) (2)

COMECO reserves the right of changing specifications without prior notice!

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


temperature probes ATEX T/C PROBE WITH (MI) INSERT - FOR IN-HEAD TRANSMITTER ** II 2 G Ex d IIC T6 Gb -20°C≤Ta≤+65°C II 2 D Ex tb IIIC T80 °C Db IP65

TSCSx - EX TSOCSx - EX

DIMENSIONS SENSITIVE ELEMENT

TEMPERATURE RANGE

d [mm]

EC-type Certificate No. MP 08 ATEX 0002

d insert [mm]

wires

Regular Insert Design

DESIGN WITHOUT EXTENSION (TS(O)CS)

10, 12, 14, 16, 20

6, 8, 10

2

12, 14, 16, 20

8, 10

2x2

0...850 °C 0...1100 °C 0...1150 °C

10, 12, 14, 16, 20

6, 8, 10

2

12, 14, 16, 20

8, 10

2x2

0...850 °C 0...1000 °C

10, 12, 14, 16, 20

6, 8, 10

2

2xE

T3 T13

12, 14, 16, 20

8, 10

2x2

1xS 1xR

T16 T6*

0...1100 °C 0...1150 °C

10, 12, 14, 16, 20

6, 8, 10

2

2xS 2xR

T16 T6*

0...1100 °C 0...1150 °C

12, 14, 16, 20

8, 10

2x2

1 x J; 1 x L 2 x J; 2 x L 1xK 2xK 1xE

for n < 150 mm, contact COMECO!

EXTENDED DESIGN WITH WELDED CONNECTION (TS(O)CS1)

T4

0...800 °C

T3 T16 T6*

MI Insert Design 1xJ 2xJ 1xK 1 x N, 1 x E 2xK 2 x N, 2 x E

T4

0...800 °C

6, 8, 10, 12, 14, 16, 20

3, 4.5, 6, 8

T3 T16 T6* T6*

0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C

8, 10, 12, 14, 16, 20

4.5, 6, 8

2 2x2 2 2x2

Protection head: EG(SS), EGS, EGW(SS), EX8(SS), EX8W(SS), EX10(SS), EX10W(SS), EX8WD, EX10WD (see Appendix - Protection Heads)

EXTENDED DESIGN WITH MOVABLE CONNECTION (TS(O)CS2)

Electrical entry: - cable gland(s): SS or brass, cemented, ID 7.5 mm - threaded head conduit(s) Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Process length: n = 50…3000 mm

DESIGN WITH ADJUSTABLE CONNECTION (TS(O)CS3)

Extension length: m = 0…1500 mm Extension diameter: (for TS(O)CS1 and TS(O)CS2 only, [mm]) 6 mm

8 mm

10 mm

10+ mm

up to 50 mm

d

d

d

d

50...150 mm

8

d

d

d

150...500 mm

10

10

d

d

500+ mm

14

14

14

d

Insert tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Process pressure:

DESIGN WITH GLAND-TYPE CONNECTION (TS(O)CS4)

Probe design Max. pressure *

TS(O)CS, TS(O)CS1 TS(O)CS2 25 bar

16 bar

TS(O)CS4

TS(O)CS3

6 bar

0 bar

Sheath material: 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762/1.4749(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362(M15) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) * Please contact COMECO! ** Order transmitter separately!!!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Probe diameter 'd' Ext. length 'm'


temperature probes

Ordering code TS (1,2,3,4) - (MI -) G0'n0".G1G2.G3.G4.G6.G7.G9'9".G10.G11.G14 - #1.#2 - EX Code Feature or option

Code values

Base model variant

CS - standard (w/ terminal block), OCS - prepared for in-head transmitter (w/o terminal block)

G0'

Protection head

EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", EX8 - type "EX8", EX8SS - type "EX8SS", EX8W - type "EX8W", EX8WSS - type "EX8WSS", EX10 - type "EX10", EX10SS - type "EX10SS", EX10W - type "EX10W", EX10WSS - type "EX10WSS", EX8WD - type "EX8WD", EX10WD - type "EX10WD"

G0"

Electrical entry ('n' - number of entries (9))

G - gland, U2 - M20x1.5, U4 - G1/2", U6 - G3/4", U10 - 1/2" NPT, U11 - 3/4" NPT

G1

Number of thermocouples

1 or 2

G2

Thermocouple

G3

Temperature range

G4

Diameter 'd' / 'd insert' [mm]

G6

Probe length 'n' [mm] (1)

G7

Probe length 'm' [mm]

regular insert

E - type "E", J - type "J", K - type "K", L - type "L", R - type "R", S - type "S"

MI insert

E - type "E", J - type "J", K - type "K", N - type "N" T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (8), T13 - 0…1000 °C, T16 - 0…1100 °C

regular insert

10/6, 10/8, 12/6, 12/8, 14/6, 14/8, 14/10, 16/10, 20/10

MI insert

6/3, 8/4.5, 10/6, 12/6, 14/6, 16/6, 20/6, 20/8 50…3000

(2)

0…1500

G9'

Mounting connection

X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)

G9"

Compression fitting ferrule (4)

BR - brass, SS - stainless steel, TF - Teflon®

G10

Sheath material (wetted parts and insert)

regular insert

M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4401 (1.4404), M15 - 1.4362

MI insert

M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M8 - 2.4816, M9 - 1.4401 (1.4404)

G11

Accuracy class

1 - '1' (8), 2 - '2'

G14

Insert tip shape (hot junction)

X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design

#1

Options

X - none, OV - vibration proof (secured screws) (5), OS - spring-loaded insert, OT - thermal isolation (3), OP - electrochemically polished wetted parts

#2

Incorporated devices

X - none, T - in-head transmitter (6), A - local indicator (7)

(1)

'n+m' for TS(O)CS3 and TS(O)CS4! Only for TS(O)CS1 and TS(O)CS2! (3) Only for TS(O)CS! (4) Only for TS(O)CS4! (5) Requires 'OS' option! (6) Only for variant 'OCS'! See transmitter datasheets and order separately! (7) With windowed head only! See indicator datasheets and order separately! (8) Contact COMECO! (9) Applicable for the selected head type (see Appendix - Protection Heads)

COMECO reserves the right of changing specifications without prior notice!

(2)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,



transmitters Fixed-Input Temperature Transmitter TRN ♦ ♦ ♦ ♦ ♦ ♦

Low cost 2- or 3-wire output line connection High resistance to electromagnetic disturbances ZERO and SPAN adjustment In-head and DIN-rail versions IP65 box and Ex housing available

COMECO's current loop transmitter TRN converts the signal from a temperature sensor into standard current or voltage signal that can be safely sent over long distances to remote indicators, data loggers, or controllers. In addition to the most common thermoresistance and thermocouple sensors, TRN may convert linear analog input signals (current or voltage). The transmitter is based on high-tech integral circuits and has fixed input range. Two-wire- and three-wire-output variants are offered. Both are available in case for mounting inside sensor protection head, in watertight box with high protection class, in case for mounting on a DIN rail, and in case prepared for mounting in Ex housings. TRN can withstand considerable electromagnetic disturbances and is a perfect low-cost solution for general-purpose applications.

Technical specifications Input

Accuracy min. -50...max. 500 °C (1) min. -50...max. 250 °C (1) min. -50...max. 250 °C (1) min. -50...max. 500 °C (1) min. 0...max. 1000 °C (1) min. 0...max. 1000 °C (1) min. 0...max. 1300 °C (1) min. 0...max. 800 °C (1) min. 0...max. 800 °C (1) min. 0...max. 400 °C (1) min. 0...max. 600 °C (1) min. 0...max. 20 mA (1) min. 0...max. 10 V (1) RTD: 50 °C, T/C: 250 °C ± 10%

Pt50...1000; 2- or 3-wire Cu100; 2- or 3-wire Cu50; 2- or 3-wire Other thermoresistive Thermocouple "E" Thermocouple "J" Thermocouple "K" Thermocouple "L" Thermocouple "L - GOST" Thermocouple "T" Thermocouple "U" Linear current Linear voltage Minimum input range width ZERO and SPAN adjustment

Output 4...20 mA 0...5 mA, 0(4)...20 mA 0...1/ 2/ 5/ 10 V, 1...5 V, 2...10 V temperature input voltage Low: < 3.5 mA, High: > 23 mA Low or High, depends on terminal High

2-wire current 3-wire current 3-wire voltage RTD linearly proportional to T/C linearly proportional to Current limits Reaction at RTD failure Reaction at T/C failure

Measurement error Non-linearity for RTD input Self-heating error Temperature drift Cold junction compensation

0.3% from span 0.3% from span 0.02%/mA at 24 V 0.02% from span for 1 °C automatic hardware, ± 1 °C

Power supply Supply voltage: - for 2-wire output - for 3-wire current output - for 3-wire voltage output Consumption Admissible variations Maximum line load

8...32 VDC (for RTD / linear input) or 12...36 VDC (for T/C input) 8...36 VDC (Umax+3)...36 VDC up to 2 mA (3-wire output) 1 Vp-p at 50 Hz 620 Ω (750 Ω for T/C) at 24V/20mA

Operating conditions -20...70 °C 0...95 %RH, non-condensing

Ambient temperature Ambient humidity

Design and materials Case material Wiring Mounting Dimensions [mm] Weight Protection class

in head (2,3,4) ø44x19 30 g IP20

plastic screw terminals on rail in box (3) 18x90x58 80x80x60 90 g 170 g IP20 IP65

(1)

Specify lower and upper span ranges when ordering. Head type "B" or any other with 33 mm distance between centers of the female threaded openings May be mounted on rail by a special snap-on accessory, which is ordered separately (see 'Accessories'). (4) May be mounted in different, separately ordered Ex housings for field applications (see 'Accessories'). (2)

Ordering code

TRN - G6'6".G11'11".G12

Code Feature or option G6'

G6"

(5)

Code values

Variant

2 - with 2-wire output line, 3 - with 3-wire output line

Input signal

Sensor

B - thermoresistance, C - thermocouple, D - linear RTD

B - Pt50, D - Pt100, F - Pt500, G - Pt1000, H - Cu50, K - Cu100, Z - other

T/C

J - "J", K - "K", E - "E", L - "L", T - "T", U - "U"

linear

A - 0…5 mA, B - 0…20 mA, C - 4…20 mA, H - 0…1 V, I - 0…2 V, J - 0…5 V, K - 0…10 V, Z - other

G11'

Output signal (5)

B - 0…5 mA, C - 1…5 mA, D - 2…10 mA, E - 0…20 mA, F - 4…20 mA, G - 0…1 V, H - 0…2 V, I - 0…5 V, J - 1…5 V, K - 0…10 V, L - 2…10 V, Z - other

G11"

Transmission range

(RANGE) (see table above)

G12

Mounting

B - in head (2,3), C - on DIN rail, D - in box IP65 (box included) (3), E - in Ex housing (includes mounting kit only)

For 2-wire output line, output signal can only be 4...20 mA (G11' = "F")!!!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(3)


transmitters Transmitter with Selectable Input TRA ♦ ♦ ♦ ♦ ♦ ♦ ♦

Low cost High resistance to electromagnetic disturbances Up to 10 selectable ranges for Pt100 sensors Up to 10 selectable thermocouples In-head and DIN-rail versions ATEX approved version IP65 box and Ex housing available

COMECO's temperature transmitter TRA is a compromising solution between the analog transmitters with fixed range and the programmable transmitters. TRA allows on-site selection of input range and sensor type (for thermocouples) as well as transmitter reaction to sensor failure by the means of a group of soldering bridges (jumpers). The exact range is adjustable by ZERO and SPAN potentiometers. TRA is available in case for mounting inside sensor protection head, in watertight box with high protection class, in case for mounting on a DIN rail, and in case prepared for mounting in Ex housings. An ATEX approved version is also available, and when used with external Zener barrier, all other transmitter versions are applicable for Ex zones. Thanks to its flexibility, excellent resistance against electromagnetic disturbances, and low price, TRA is easy to use and very widely applicable.

Technical specifications Input

Accuracy

Pt100 (w=1.385); 3-wire Thermocouple "E" Thermocouple "J" Thermocouple "K" Thermocouple "L" (2) Thermocouple "L - GOST" (2) Thermocouple "N" Thermocouple "R" (3) Thermocouple "S" (3) Thermocouple "T" Thermocouple "U" (3) Range selection Thermocouple selection ZERO adjustment SPAN adjustment

0…50/ 100/ 150/ 200/ 300/ 400/ 500 °C; -50…50/ 100 °C (1); 0…250 °C (1) 0...300/ 400/ 500/ 600 °C 0...400/ 500/ 600/ 800 °C 0...600/ 800/ 1000/ 1200 °C 0...700 °C 0...600 °C 0...800/ 1000/ 1200 °C 0...1200/ 1400/ 1600 °C 0...1200/ 1400/ 1600 °C 0...100/ 200/ 300 °C 0...100/ 200/ 300/ 400 °C with jumpers with jumpers ± 50 °C ± 10% ± 10%

Output Signal type RTD linearly proportional to T/C linearly proportional to Current limits Reaction at RTD failure: - for variant '1' - for variant '2' Reaction at T/C failure

4...20 mA temperature input voltage Low: < 3.5 mA, High: > 23 mA Low or High depends on terminal selectable High

Measurement error Non-linearity Self-heating error Temperature drift Cold junction compensation

0.3% from span 0.3% from span 0.02%/mA at 24 V 0.02% from span for 1 °C automatic hardware, ± 1 °C

Power supply Supply voltage Admissible variations Maximum line load: - for variant '1' - for variant '2'

8...32 VDC 1 Vp-p at 50 Hz 620 Ω (800 Ω for T/C) at 24V/20mA 700 Ω (800 Ω for T/C) at 24V/20mA

Operating conditions Ambient temperature: - for variant '1' - for variant '2' Ambient humidity

-20...70 °C -40...85 °C 0...95 %RH, non-condensing

Design and materials Case material Wiring Mounting Dimensions [mm] Weight Protection class

(4,5,6)

in head ø44x19 30 g IP20

plastic screw terminals (1) on rail in box (5) 18x90x58 80x80x60 90 g 170 g IP20 IP65

(1)

Available only for variant '1'. Ask for availability! Available only when in case for DIN-rail mounting (G12 = "C")! (4) Head type "B" or any other with 33 mm distance between centers of the female threaded openings (5) May be mounted on rail by a special snap-on accessory, which is ordered separately (see 'Accessories'). (6) May be mounted in different, separately ordered Ex housings for field applications (see 'Accessories'). (3)

Ordering code

TRA - G6.G12 - #1.#2

Code Feature or option

(7) (8)

Code values

Variant

1, 2

G6

Input

B - Pt100, C - thermocouple (7)

G12

Mounting

B - in head (4,5), C - on DIN rail (1), D - in box IP65 (box included) (5), E - in Ex housing (includes mounting kit only)

#1

Pre-set transmission range

X - none, (RANGE) (see table above)

#2

ATEX approval

X - none, EX - ATEX II 1G Ex ia IIB T4-T6 approved (8)

Thermocouple type is user selectable by jumpers. Available only for variant '2'.

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(2)


transmitters Programmable In-head RTD Transmitter TROJ ♦ ♦ ♦ ♦ ♦ ♦ ♦

For low-budget applications Pt100 input Programmable conversion range 2-wire 4…20 mA output Low profile Vibration-proof design Programming via free "TraCon" software

Technical specifications Input Input (RTD) type Measurement range Minimum programmable span

Output Signal type Maximum load Sensor failure reaction

(programmable) Pt100 (w=1.385) min. -50...max. 200 °C or min. -50...max. 600 °C 50 °C (programmable) 4...20 mA or 20...4 mA, 2-wire 800 Ω at 24V/20mA < 3.9 mA or > 20.2 mA, programmable

Accuracy Measurement error Self-heating error Non-linearity Temperature drift RTD 3-wire line compensation

0.2% from span or 0.2 °C (1) 0.005%/mA at 24 V within measurement error 0.01% from span for 1 °C up to 25 Ω per wire

Power supply 10...32 VDC 1 Vp-p at 50 Hz

Loop supply voltage Admissible variations

Interface Interface type Configuration software

RS232, requiring special cable (2) "TraCon", free

Operating conditions Ambient temperature Ambient humidity

-20...70 °C 0...95 %RH, non-condensing

Design and materials Case material Wiring Mounting Interface connector Interface cable type (2) Dimensions [mm] Weight Protection class

in head (3,4,5) 4-pin K1, K11U ø44x19 25 g IP20

plastic screw terminals in box (4) 4-pin K1, K11U 80x80x60 170 g IP65

(1)

Which is greater Ordered separately (3) Head type "B" or any other with 33 mm distance between centers of the female threaded openings (4) May be mounted on rail by a special snap-on accessory, which is ordered separately (see 'Accessories'). (5) May be mounted in different, separately ordered Ex housings for field applications (see 'Accessories'). (2)

Ordering code

TROJ - G12

Code Feature or option

1 - for min. -50...max. 200 °C, 2 - for min. -50...max. 600 °C

Mounting

B - in head (3,4), D - in box IP65 (box included) (4), E - in Ex housing (includes mounting kit only)

COMECO reserves the right of changing specifications without prior notice!

G12

Code values

Variant

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


transmitters Low-cost Programmable Transmitter TRC ♦ ♦ ♦ ♦ ♦ ♦

Smallest in-head programmable transmitter Pt100 and 8 T/C programmable ranges 2- or 3-wire current and voltage output Serial interface for configuration In-head and DIN-rail versions IP65 box and Ex housing available

COMECO's temperature transmitter TRC is part of a revolutionary new project for the smallest (in-head) and cheapest multi-input programmable transmitter. It has a universal input accepting Pt100 RTD and 8 thermocouples and a voltage or current 2- or 3-wire output linearly proportional to the measured temperature. This model allows on-site selection of sensor type, input range and conversion direction as well as sensor failure reaction and no user calibration is necessary to be provided. TRC is available in a case for mounting inside sensor protection head, in a watertight box with high protection class, and in a case for mounting on DIN rail. The serial interface allows fast and easy configuration. Thanks to the combination of performance, reliability, simplicity, flexibility, and low price, the TRC transmitter is easy to use and very widely applicable.

Technical specifications Input

(programmable) min. -200…max. 600 °C min. 200...max. 1800 °C min. -20...max. 600 °C min. -20...max. 900 °C min. -20...max. 1200 °C min. -20...max. 1200 °C min. 0...max. 1700 °C min. 0...max. 1700 °C min. -40...max. 400 °C direct or reverse, programmable

Pt100 (w=1.385); 3-wire Thermocouple "B" Thermocouple "E" Thermocouple "J" Thermocouple "K" Thermocouple "N" Thermocouple "R" Thermocouple "S" Thermocouple "T" Input / output conversion

Output

'2'

Voltage - minimum load Current - maximum load Sensor failure reaction

'3'

0...10 V 1 MΩ 0(4)...20 mA 4...20 mA 750 Ω at 24V/20mA 800 Ω at 24V/20mA < 3.9 mA or > 20.2 mA, downscale or upscale, programmable programmable

Power supply Supply voltage Admissible variations

8...36 VDC 1 Vp-p at 50 Hz

9...36 VDC (1) 1 Vp-p at 50 Hz

Accuracy 0.3% from span within measurement error 0.005%/mA at 24 V 0.01% from span for 1 °C automatic software, ± 0.5 °C up to 25 Ω per wire

Measurement error Non-linearity Self-heating error Temperature drift Cold junction compensation RTD 3-wire line compensation

Interface RS232, requiring special cable (2) "TraCon", free

Interface type Configuration software

Operating conditions -20...70 °C 0...95 %RH, non-condensing

Ambient temperature Ambient humidity

Design and materials Case material Wiring Mounting Interface connector Interface cable type (2) Dimensions [mm] Weight Protection class

in head (3,4,5) 4-pin K1, K11U ø44x19 30 g IP20

plastic screw terminals in box (4) on rail 3-pin 4-pin K2, K12U K1, K11U 18x90x58 80x80x60 90 g 170 g IP20 IP65

(1)

13...36 VDC for output 0...10 V Ordered separately Head type "B" or any other with 33 mm distance between centers of the female threaded openings (4) May be mounted on rail by a special snap-on accessory, which is ordered separately (see 'Accessories'). (5) May be mounted in different, separately ordered Ex housings for field applications (see 'Accessories'). (2) (3)

Code Feature or option G11 G12 (6)

Variant

Code values 2 - with 2-wire output line, 3 - with 3-wire output line

Output signal (6)

E - 0…20 mA, F - 4…20 mA, K - 0…10 V, Z - other

Mounting

B - in head (3,4), C - on DIN rail, D - in box IP65 (box included) (4), E - in Ex housing (includes mounting kit only)

For 2-wire output variant only 4...20 mA is available!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code TRC - G11.G12


transmitters Low-cost SMART Transmitter TRB ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

Universal programmable input User-selectable 4 RTD types and 6 thermocouples Accepts linear current, voltage, and resistive signals Programmable input and output range Built-in programmable digital filter Manual output control Serial interface for programming IP65 box and Ex housing available

The intelligent non-isolated transmitter TRB, manufactured by COMECO, is available in case prepared for mounting in Ex housings, in casing for in-head mounting, and in another for DIN-rail mounting, as well as mounted into an IP65 protection box. This transmitter allows the user to: - select sensor and input signal type; - select and adjust input range; - perform offset correction and device calibration; - specify input ranges and output type (4…20 mA / 20…4 mA); - select decimal point position and measurement unit; - select output reaction at sensor failure; - adjust the digital filter. The TRB transmitter is easy to program via the specialized configuration software "TraCon". Thanks to its large capabilities and low price, TRB can be very useful in various industrial applications requiring temperature conversion before following measurement and control.

Technical specifications Pt100 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire PTC (1k at 25 °C); 3-wire PTC (2k at 25 °C); 3-wire RTD minimum range width Thermocouple "T" Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" T/C minimum range width Linear current Linear voltage Linear resistive Custom linear (option) Offset adjustment Digital low-pass filter Digital peak filter

Input monitoring Sensor failure reaction

(programmable) min. -100...max. 850 °C min. -100...max. 600 °C min. -50...max. 150 °C min. -50...max. 150 °C 50 °C min. -40...max. 400 °C min. -20...max. 1000 °C min. -20...max. 1300 °C min. 0...max. 1700 °C min. 0...max. 1700 °C min. 200...max. 1800 °C 100 °C 0(4)...20 mA 0...100 mV or 0...10 V (1) 0...1 kΩ on request (2) within range limits programmable programmable (programmable) < 3.8 mA or > 20.2 mA, programmable

Output

(programmable) 4...20 mA or 20...4 mA measured value 4 μA through interface 0...100%, programmable

Signal type Linearly proportional to Resolution Output calibration Manual output control

Accuracy Measurement error Non-linearity Temperature drift Cold junction compensation

0.3% from span within measurement error 0.01% from span for 1 °C automatic software, ± 0.5 °C

Power supply 8...32 VDC ± 10% 750 Ω at 24V/20mA

Supply voltage Maximum line load

Interface RS232, requiring special cable (3) "TraCon", free

Interface type Configuration software

Operating conditions -20...70 °C 0...95 %RH, non-condensing

Ambient temperature Ambient humidity

Design and materials Case material Wiring Mounting Interface connector Interface cable type (3) Dimensions [mm] Weight Protection class

in head (4,5,6) 4-pin K1, K1U, K11U ø44x23 40 g IP20

(1)

Ask for availability! Instead of linear current (3) Ordered separately (4) Head type "B" or any other with 33 mm distance between centers of the female threaded openings (5) May be mounted on rail by a special snap-on accessory, which is ordered separately (see 'Accessories'). (6) May be mounted in different, separately ordered Ex housings for field applications (see 'Accessories'). (2)

Ordering code

TRB - G12 - #1

Code Feature or option

Code values

G12

Mounting

B - in head (4,5), C - on DIN rail, D - in box IP65 (box included) (5), E - in Ex housing (includes mounting kit only)

#1

Auxiliary input signal

X - none, Z - linear signal (specify!) (2)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

plastic screw terminals in box (5) on rail 3-pin 4-pin K2, K1, K2U, K12U K1U, K11U 18x90x58 80x80x60 60 g 180 g IP20 IP65

COMECO reserves the right of changing specifications without prior notice!

Input


transmitters Isolated SMART Transmitter TRBI ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

1500 VAC input / output isolation Universal programmable input User-selectable 4 RTD types and 6 thermocouples Accepts linear current, voltage, and resistive signals Programmable input and output range Built-in programmable digital filter Manual output control Serial interface for programming IP65 box and Ex housing available

The intelligent isolated transmitter TRBI, manufactured by COMECO, is available in case prepared for mounting in Ex housings, in casing for in-head mounting, and in another for DIN-rail mounting, as well as mounted into an IP65 protection box. This transmitter allows the user to: - select sensor and input signal type; - select and adjust input range; - perform offset correction and device calibration; - specify input ranges and output type (4…20 mA / 20…4 mA); - select decimal point position and measurement unit; - select output reaction at sensor failure; - adjust the digital filter. The TRBI transmitter is easy to program via the specialized configuration software "TraCon". Thanks to its large capabilities and low price, TRBI can be very useful in various industrial field applications requiring signal isolation.

Technical specifications Pt100 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire PTC (1k at 25 °C); 3-wire PTC (2k at 25 °C); 3-wire RTD minimum range width Thermocouple "T" Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" T/C minimum range width Linear current Linear voltage Linear resistive Custom linear (option) Offset adjustment Digital low-pass filter Digital peak filter Input / output isolation

Input monitoring Sensor failure reaction

(programmable) min. -100...max. 850 °C min. -100...max. 600 °C min. -50...max. 150 °C min. -50...max. 150 °C 50 °C min. -40...max. 400 °C min. -20...max. 1000 °C min. -20...max. 1300 °C min. 0...max. 1700 °C min. 0...max. 1700 °C min. 200...max. 1800 °C 100 °C 0(4)...20 mA 0...100 mV or 0...10 V (1) 0...1 kΩ on request (2) within range limits programmable programmable 1500 VAC for 1 min (programmable) < 3.8 mA or > 20.2 mA, programmable

Output

(programmable) 4...20 mA or 20...4 mA measured value 4 μA through interface 0...100%, programmable

Signal type Linearly proportional to Resolution Output calibration Manual output control

Accuracy Measurement error Non-linearity Temperature drift Cold junction compensation

0.3% from span within measurement error 0.01% from span for 1 °C automatic software, ± 0.5 °C

Power supply 8...32 VDC ± 10% 750 Ω at 24V/20mA

Supply voltage Maximum line load

Interface RS232, requiring special cable (3) "TraCon", free

Interface type Configuration software

Operating conditions -20...70 °C 0...95 %RH, non-condensing

Ambient temperature Ambient humidity

Design and materials Case material Wiring Mounting Interface connector Interface cable type (3) Dimensions [mm] Weight Protection class

in head (4,5,6) 4-pin K1, K1U, K11U ø44x23 40 g IP20

(1)

Ask for availability! Instead of linear current Ordered separately (4) Head type "B" or any other with 33 mm distance between centers of the female threaded openings (5) May be mounted on rail by a special snap-on accessory, which is ordered separately (see 'Accessories'). (6) May be mounted in different, separately ordered Ex housings for field applications (see 'Accessories'). (2) (3)

Ordering code

TRBI - G12 - #1

Code Feature or option

Code values

G12

Mounting

B - in head (4,5), C - on DIN rail, D - in box IP65 (box included) (5), E - in Ex housing (includes mounting kit only)

#1

Auxiliary input signal

X - none, Z - linear signal (specify!) (2)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

plastic screw terminals in box (5) on rail 3-pin 4-pin K2, K1, K2U, K12U K1U, K11U 18x90x58 80x80x60 60 g 180 g IP20 IP65

COMECO reserves the right of changing specifications without prior notice!

Input


transmitters HART Programmable Transmitter TRH ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

2000 VAC input / output isolation Universal programmable input User-selectable 8 RTD types and 8 thermocouples Accepts various linear voltage and resistive signals Programmable input and output features Built-in digital filter Manual output control Programming via HART protocol Free configuration software Intrinsically safe version

The intelligent isolated transmitter TRH is a programmable 2-wire HART device with 2000 V input/output isolation level. It is available in case prepared for mounting in 33 mm sensor heads, plastic protection box, and different Ex housings. The transmitter allows the user to program various input and output features including input signal type and range, output offset and calibration, reaction at sensor failure, fixed output current, digital filter, etc. TRH can be ordered with intrinsically safe option for Ex applications. The transmitter is easy to program via HART modem over the current loop using free configuration software "HartTemp". Thanks to its large capabilities and low price, TRH can be very useful in various industrial field applications requiring signal isolation and HART communication.

Technical specifications Pt100; 3(4)-wire Pt500 (Pt1000); 3(4)-wire (5) Cu50 (Cu100); 3(4)-wire Ni100; 3(4)-wire Ni500 (Ni1000); 3(4)-wire (5) RTD minimum range width Thermocouple "T" Thermocouple "E" Thermocouple "J" Thermocouple "K" Thermocouple "N" Thermocouple "S"("R") Thermocouple "B" T/C minimum range width Linear voltage [mV] Linear voltage [V] Minimum range [mV] Linear resistive Minimum range [Ω] Input / output isolation

Output Output range Linearly proportional to Resolution Response time Switch-on delay Digital filter Output calibration Output manual control Sensor failure reaction (1) (2) (3)

Measurement error - Pt500, Ni500 - Pt1000, Ni1000, Cu100, 0...2 kΩ - other input types Non-linearity Temperature drift Load and power supply influence Long-term stability Cold junction compensation Supply voltage Maximum line load

Communication Configuration software

HART protocol over current loop "HartTemp", free

Operating conditions Ambient temperature Ambient humidity Shocks and vibrations

-40...85 °C 0...90 %RH 4g, 2...150 Hz, according to EN 60068

Design and materials Case material Wiring Mounting Dimensions Weight Protection class Intrinsic safety

Code values

Mounting

B - in head (1,2), D - in box IP65 (box included) (2), E - in Ex housing (includes mounting kit only) (4)

#1

Intrinsic safety

X - none (5), E - Ex ia IIC T4 certified

#2

Customized input and/or range

X - none, Z - custom input signal/range (specify!) (5)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

7.5...45 VDC 750 Ω at 24V/20mA

Interface

G12

Does not include housing! Contact COMECO

0.2 % from span 0.12 % from span 0.08 % from span within measurement error negligible negligible ≤ 0.05% from span per 1 year internal, automatic

Power supply

TRH - G12 - #1.#2

Code Feature or option

(5)

Accuracy

Head type "B" or any other with 33 mm distance between centers of the female threaded openings May be mounted on rail by a special snap-on accessory, which is ordered separately (see 'Accessories'). May be mounted in different, separately ordered Ex housings for field applications (see 'Accessories').

Ordering code

(4)

(programmable) min. -200...max. 850 °C min. -200...max. 250 °C min. -50...max. 150 °C min. -60...max. 180 °C min. -60...max. 180 (150) °C 10 °C min. -270...max. 400 °C min. -270...max. 1000 °C min. -210...max. 1200 °C min. -270...max. 1372 °C min. -270...max. 1300 °C min. -50...max. 1768 °C min. 0...max. 1820 °C 50 °C (500 °C for noble T/C) -10...75 mV, -100...100 mV (5) -0.5...0.5 V (5), -1...2 V (5) 5 mV (20 mV for 2 V range) min. 0...max. 400(2000) Ω 10 Ω (20 Ω for 2 k range) 2000 VAC for 1 min (programmable) 4...20 mA, 2-wire measured value 0.3 μA 1s ≤5s programmable configuration software 0...100% via configuration software ≤ 3.8 mA, ≥ 20.5 mA

PC plastic with epoxy potting screw terminals in box (2) in head (1,2,3) 80x80x60 mm ø44x24 mm approx. 34 g approx. 170 g IP65 IP00 Ex ia IIC T4 Ex ia IIC T4

COMECO reserves the right of changing specifications without prior notice!

Input


transmitters Universal Isolated SMART Transmitter TRZ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

11-pin relay socket for fast rail mounting 1500 VAC input / output / supply isolation Programmable input Programmable output Internally generated sensor supply Built-in programmable digital filter Manual output control Serial interface for programming

The intelligent isolated transmitter TRZ can be a proper solution when different signal conversions are needed. This transmitter allows the user to: - select sensor and input signal type (RTD, T/C, mA, mV, V, R); - select and adjust input range; - select output type (0(4)...20 mA or 0...10 V); - control the output manually; - perform offset correction and device calibration; - specify the input-to-output correspondence (direct or reverse); - select decimal point position and measurement unit; - select output reaction at sensor failure; - adjust the digital filter. The TRZ transmitter is easy to program via the specialized configuration software "TraCon". Thanks to its convenient 11-pin connector case, TRZ can be easily fit in a standard UNDECAL socket and mounted on DIN rail.

Technical specifications (programmable) min. -200...max. 850 °C min. -100...max. 600 °C min. -50...max. 150 °C min. -50...max. 150 °C 50 °C min. -40...max. 400 °C min. -20...max. 1000 °C min. -20...max. 1300 °C min. 0...max. 1700 °C min. 0...max. 1700 °C min. 200...max. 1800 °C 100 °C 0(4)...20 mA 0...100 mV, 0…10 V 0...1 kΩ on request (1) within range limits programmable programmable 1500 VAC for 1 min

Pt100 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire PTC (1k at 25 °C); 3-wire PTC (2k at 25 °C); 3-wire RTD minimum range width Thermocouple "T" Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" T/C minimum range width Linear current Linear voltage Linear resistive Custom linear (option) Offset adjustment Digital low-pass filter Digital peak filter Input / output isolation

Input monitoring

(programmable) 0 mA or > 20.2 mA, programmable

Sensor failure reaction

Output

(programmable) 0(4)...20 mA or 20...0(4) mA max. 600 Ω at 20 mA 0...10 V or 10...0 V min. 2 kΩ at 10 V measured value 4 μA / 2.5 mV through interface 0...100%, programmable 18…28 VDC, max. 30 mA

Current - load Voltage - load Linearly proportional to Resolution Output calibration Manual output control Excitation voltage (1) (2)

Accuracy Measurement error Non-linearity Temperature drift Cold junction compensation

Power supply Mains supply voltage Isolated low voltage Consumption

'Power' LED 'Load' LED 'Alarm' LED

Interface type Configuration software

RS232, requiring special cable (2) "TraCon", free

Operating conditions Ambient temperature Ambient humidity

-20...70 °C 0...95 %RH, non-condensing

Design and materials Case material Mounting Wiring Interface connector Interface cable type (2) Dimensions Weight Protection class

Code values

G1

Power supply

A - 230 VAC, B - 115 VAC, Q - 12…24 V, isolated, R - 24 VAC

#1

Auxiliary input signal

X - none, Z - linear signal (specify!) (1)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

for power supply ON for voltage output overload for broken current output loop

Interface

TRZ - G1 - #1

Code Feature or option

230 VAC or 115 VAC ± 10% 12…24 V or 24 VAC max. 1.5 VA

Indication

Instead of linear current or voltage 0...10 V Ordered separately (see 'Accessories')

Ordering code

0.3% from span within measurement error 0.01% from span for 1 °C automatic software, ± 0.5 °C

plastic in socket or on 35 mm DIN rail socket UNDECAL (2) 3-pin K2 (RS232) or K12U (USB) 35x78x91 mm 180 g IP20

COMECO reserves the right of changing specifications without prior notice!

Input


transmitters Infrared Temperature Transmitter TRU ♦ ♦ ♦ ♦ ♦ ♦ ♦

Low-temperature remote measurement Object temperature range from -10 to 150 °C Field of view 7.3 ° Linear current or voltage output signal Serial interface available Local programmable indicator available IP66 protection class

The TRU temperature transmitter's operation is based on the principle of sensing infrared radiation, emitted from a heated object, situated at a certain distance from the sensor, at a 7.3 ° conical angle. The sensitive thermopile element comprises of a multitude of thermocouples connected in series and allows measurement of the object surface temperature within the -10…150 °C range. The incorporated electronics converts the sensor output into a standard current or voltage signal suitable for further transmission and processing. Moreover, the transmitter may be equipped with programmable local LED indicator as well as with RS232 serial interface for data transmitting. By the means of specialized software, the information about the object's temperature may be viewed, stored, and printed from a PC. TRU is enclosed in a robust plastic box with connector, both with IP66, and is designed to be either freely mounted or mounted on DIN rail via special brackets. The TRU transmitter is very suitable for these special applications that require non-contact low-temperature-object measurement.

Technical specifications Input

Interface

Input type Material emission coefficient Object temperature range Calibrating distance Calibrating spot Field of view

object infrared emission 5...15 μm ≥ 0.85 min. -10...max. 150 °C 5 cm 3.5 cm 7.3 °

Analog output Output signal Output function Accuracy Temperature drift Maximum output load Output overload reaction

0(4)...20 mA or 0...10 V input signal info retransmission 2% from span 0.02% from span for 1 °C 750 Ω at 24V/20 mA display message

Local indicator (option) 3 LED indicators, 14 mm 1 °C 2 membrane keys

Digital display Display resolution Keyboard

Power supply Supply voltage Admissible variations Consumption

15...32 VDC 4 Vp-p at 50 Hz max. 120 mA

Operating conditions Ambient temperature Storage temperature

-10...65 °C -20...85 °C

Design and materials Case material Mounting Wiring Dimensions Weight Protection class

ABS/PC plastic free (1) 4-pin М12 connector 80x92x65 mm max. 250 g IP66

Radial, axial, and DIN-rail mounting accessories for 80x80x60 mm box can be ordered separately (see 'Accessories').

Ordering code

TRU - G9.G11 - #1

Code Feature or option

(2)

RS232 data transmission

Code values

G9

Serial interface

X - none, A - RS232

G11

Analog output

X - none (2), E - 0…20 mA, F - 4…20 mA, K - 0…10 V, Z - other on request

#1

Local indicator (2)

X - none, A - local indicator mounted

When no output is requested, local indicator must be ordered!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(1)

Interface type Function


transmitters RS485 SMART DIN-Rail Transmitter TRIS ♦ ♦ ♦ ♦ ♦ ♦ ♦

Low-cost network transmitter - up to 32 devices Universal programmable input User-selectable 4 RTD types and 6 thermocouples Accepts linear current and voltage signals Built-in programmable digital filter Convenient programming through RS485 Input / output / supply isolation

TRIS is an intelligent rail-mountable transmitter with universal input and RS485 output, specially designed for multi-point process measurement and data acquisition in a network with up to 32 devices. This transmitter allows the user to: - select sensor and input signal type (4 RTD types, 6 thermocouples, and 4 linear signals); - select and adjust input range; - perform offset correction and device calibration; - select decimal point position and measurement unit; - adjust the digital filter. A network of up to 32 transmitters can be configured and monitored by using the universal COMECO data-acquisition program "PolyMonitor". Thanks to its isolated universal input, networking capabilities, and low price, TRIS is particularly suitable for multi-point data acquisition applications.

Technical specifications Input Pt100 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire PTC (1k at 25 °C); 3-wire PTC (2k at 25 °C); 3-wire RTD minimum range width Thermocouple "T" Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" T/C minimum range width Linear current Linear voltage Custom linear (option) Offset adjustment Digital low-pass filter Digital peak filter Isolation

(programmable) min. -100...max. 850 °C min. -100...max. 600 °C min. -50...max. 150 °C min. -50...max. 150 °C 50 °C min. -40...max. 400 °C min. -20...max. 1000 °C min. -20...max. 1300 °C min. 0...max. 1700 °C min. 0...max. 1700 °C min. 200...max. 1800 °C 100 °C 0(4)...20 mA 0...100 mV or 0…10 V on request (1) within range limits programmable programmable > 1000 VAC for 1 min

(2)

Configuration software Monitoring and data acquisition software

Accuracy Measurement error Non-linearity Temperature drift Cold junction compensation Supply voltage Consumption

Protocol

12…24 V max. 100 mA

Indication 'ON' LED 'SEL' LED

for power supply ON for active communication

Operating conditions Ambient temperature Ambient humidity Case material Wiring Mounting Dimensions Weight Protection class

TRIS - G9

Code Feature or option G9

0.3% from span within measurement error 0.01% from span for 1 °C automatic software, ± 0.5 °C

Power supply

Instead of linear current Ordered separately

Ordering code

"UniConf", free "PolyMonitor"

-20...70 °C 0...95 %RH, non-condensing

Design and materials RS485 configuration and networking up to 32 8 (data) + 1 (stop), even parity 1200 / 2400 / 4800 / 9600 bps 2500 VAC for 1 min

Interface type Function Network devices Format Baud rate Isolation (1)

(2)

Code values A - ASCII, C - ASCII for "PolyMonitor"

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

plastic plug-in terminals on 35 mm DIN rail 35x110x58 mm 90 g IP20

COMECO reserves the right of changing specifications without prior notice!

Output / Interface

Software


electrochemical control equipment

pH/ORP Preamplifier PHA ♦ ♦ ♦ ♦ ♦ ♦ ♦

Low cost 13 High input impedance – over 10 Ω Low output impedance Temperature compensation available Unipolar or bipolar supply voltage High IP protection class available May be connected to low-cost measurement devices

COMECO’s PHA preamplifier amplifies the voltage from pH or REDOX potential (ORP) probes through a special amplifier that serves as input buffer and provides the high input impedance necessary for normal operation of pH/ORP probes. The low impedance output of the preamplifier may be connected to a standard indicator, data logger, or controller. Two PHA variants are available: - variant '100' with low IP protection class that needs bipolar supply voltage; - variant '150' with high IP protection class and single polarity supply voltage. PHA100 serves only as a high input impedance buffer; no change of voltage signal is performed. PHA150 shifts input signal so that the output voltage has single polarity (its polarity does not change), and allows temperature compensation measurement via an additional Pt100 input. Variant '150' is designed for wall mounting, while PHA100 is to be either left to hang freely on its wires or mounted by the means of a bracket. Both variants are applicable in cases in which there is a need to connect pH/ORP probes to measurement devices without posing special requirements to devices' input circuits and connection cables. The fields of application include biotechnological, chemical, food, and other industries, and research.

Technical specifications Input

Accuracy

Input range: - pH - ORP Temperature compensation input Input impedance Input capacitance

Error Temperature drift

Output

0...14 pH -2000...+2000 mV external Pt100, 0...100 °C > 1013 Ω 0.5 pF

(1)

'100'

'150'

+410...-410 mV -2000...+2000 mV ± 1 mV 1 kΩ

+2910...1090 mV 500...+4500 mV 1 kΩ

± 5...± 8 VDC ± 1% max. 0.1 mA

5...9 VDC ± 5% max. 2 mA

Power supply Supply voltage Admissible variations Consumption

0...60 °C 10...85 %RH -10...70 °C 0...95 %RH

0...70 °C 0...95 %RH (2) -10...70 °C 0...95 %RH

Case material Mounting Wiring Dimensions Weight Protection class Increased IP (option)

aluminum free exposed terminals ø25x60 mm 30 g IP20 -

aluminum on wall hidden terminals 46x80x32 mm 120 g IP20 IP65

Not available for variant '100'! With increased protection

Ordering code

PHA - G6 - #1

Code Feature or option G6 #1 (3)

Operating temperature Operating humidity Storage temperature Storage humidity

Variant

100 - bipolar, 150 - unipolar

Input Increased protection

Code values DN - pH, DO - ORP

(3)

X - none, P - IP65 protection

ONLY for variant '150'

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(1)

Operating conditions

Design and materials

Output signal (at 25 °C): - pH - ORP Output asymmetry Output impedance

(2)

'100' '150' < ± 0.01% from span < ± 0.05% from span 2 μV / °C 3 μV/ °C


electrochemical control equipment

pH/ORP Preamplifier PHA ♦ ♦ ♦ ♦ ♦ ♦ ♦

Low cost 13 High input impedance – over 10 Ω Low output impedance Temperature compensation available Unipolar or bipolar supply voltage High IP protection class available May be connected to low-cost measurement devices

COMECO’s PHA preamplifier amplifies the voltage from pH or REDOX potential (ORP) probes through a special amplifier that serves as input buffer and provides the high input impedance necessary for normal operation of pH/ORP probes. The low impedance output of the preamplifier may be connected to a standard indicator, data logger, or controller. Two PHA variants are available: - variant '100' with low IP protection class that needs bipolar supply voltage; - variant '150' with high IP protection class and single polarity supply voltage. PHA100 serves only as a high input impedance buffer; no change of voltage signal is performed. PHA150 shifts input signal so that the output voltage has single polarity (its polarity does not change), and allows temperature compensation measurement via an additional Pt100 input. Variant '150' is designed for wall mounting, while PHA100 is to be either left to hang freely on its wires or mounted by the means of a bracket. Both variants are applicable in cases in which there is a need to connect pH/ORP probes to measurement devices without posing special requirements to devices' input circuits and connection cables. The fields of application include biotechnological, chemical, food, and other industries, and research.

Technical specifications Input

Accuracy

Input range: - pH - ORP Temperature compensation input Input impedance Input capacitance

Error Temperature drift

Output

0...14 pH -2000...+2000 mV external Pt100, 0...100 °C > 1013 Ω 0.5 pF

(1)

'100'

'150'

+410...-410 mV -2000...+2000 mV ± 1 mV 1 kΩ

+2910...1090 mV 500...+4500 mV 1 kΩ

± 5...± 8 VDC ± 1% max. 0.1 mA

5...9 VDC ± 5% max. 2 mA

Power supply Supply voltage Admissible variations Consumption

0...60 °C 10...85 %RH -10...70 °C 0...95 %RH

0...70 °C 0...95 %RH (2) -10...70 °C 0...95 %RH

Case material Mounting Wiring Dimensions Weight Protection class Increased IP (option)

aluminum free exposed terminals ø25x60 mm 30 g IP20 -

aluminum on wall hidden terminals 46x80x32 mm 120 g IP20 IP65

Not available for variant '100'! With increased protection

Ordering code

PHA - G6 - #1

Code Feature or option G6 #1 (3)

Operating temperature Operating humidity Storage temperature Storage humidity

Variant

100 - bipolar, 150 - unipolar

Input Increased protection

Code values DN - pH, DO - ORP

(3)

X - none, P - IP65 protection

ONLY for variant '150'

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(1)

Operating conditions

Design and materials

Output signal (at 25 °C): - pH - ORP Output asymmetry Output impedance

(2)

'100' '150' < ± 0.01% from span < ± 0.05% from span 2 μV / °C 3 μV/ °C


electrochemical control equipment pH/ORP Transmitter PHT ♦ ♦ ♦ ♦ ♦

Low cost 4 design variants 13 High input impedance – over 10 Ω Standard current or voltage output signal Automatic temperature compensation

The PHT transmitter converts the high impedance voltage output of pH or REDOX (ORP) probes into standard current or voltage signal that can be safely sent over longer distances. The transmitter provides the necessary for the normal pH/ORP probe's operation high input impedance as well as temperature compensation of pH measurement through a Pt100 or Pt1000 temperature sensor connected to the second transmitter input. Four variants are available differing by power supply, output signal, type of mounting, and protection class. The PHT transmitter is applicable in all cases in which there is a need for measuring pH or ORP and the measurement signal has to be sent over relatively long distance from the point of measurement.

Technical specifications Inputs

Accuracy

pH/ORP input

Measurement error Temperature drift

0...14 pH, 2...12 pH, -1...+1 V, -2...+2 V > 1013 Ω 0.5 pF external Pt100 or Pt1000, 0...100 °C

Input impedance Input capacitance Temperature compensation input

Variant

< ± 0.2% from span 0.005% from span for 1 °C

Operating conditions Ambient temperature Ambient humidity Storage temperature Storage humidity

0...60 °C 10...85 %RH -10...70 °C 0...95 %RH

10

30

50

100

2-wire 4…20 mA

2-wire 4…20 mA

2-wire 4…20 mA

0(4)…20 mA, 0…2 V, or on request

8…30 VDC (1)

8…30 VDC (1)

8…30 VDC (1)

230 VAC

IP20

IP44 (except BNC connector)

IP65 (except BNC connector)

IP56 (except BNC connector)

Output Power supply Protection

plastic

plastic

aluminum

plastic

ø43x30 mm

90x90x40 mm

46x80x32 mm

108x108x60 mm

Housing Dimensions

30 g

120 g

150 g

280 g

in head type "B" (2)

on wall (2) hidden screw terminals or BNC connector

on wall hidden screw terminals or BNC connector

on wall hidden screw terminals or BNC connector

Weight Mounting Probe connection (1) (2)

exposed screw terminals

12…32 VDC with ORP input May be mounted on rail by a special snap-on accessory, which is ordered separately (see 'Accessories')

Ordering code

PHT - G6'6"G6'6".G11'11".G12

Code Feature or option

10 - tablet, 30 - in IP44 plastic box, 50 - with IP65 metal enclosure, 100 - for mains power supply

G6'6"

Input

G11'

Output signal (3)

G11"

Transmission range

G12

Code values

Variant

Probe connection

pH/ORP

DN - pH, DO - ORP

temperature

BD - Pt100, BG - Pt1000 E - 0…20 mA, F - 4…20 mA, H - 0…2 V, Z - other (specify!)

(4)

(RANGE) (see table above) X - screw terminals, B - BNC connector

(3)

Applicable for the selected variant (4) Do not code for variant '10'

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Specifications


electrochemical control equipment Conductivity Transmitter / Controller PHC20 ♦ ♦ ♦ ♦ ♦ ♦ ♦

DIN-rail mounting Operates with 2-electrode contacting cells 0.1...100000 µS measurement range Relay alarm / control output Analog retransmission output Pt1000 temperature compensation Fully programmable

PHC20 is a reliable conductivity transmitter, enclosed in a small housing for DIN-rail mounting, especially designed for clear, industrial, and sea water applications. It is compatible with COMECO's conductivity probes series CSK as well as other 2-electrode contacting conductivity cells within conductance range from 0.1 µS to 100 mS, and has an additional Pt1000 input for automatic temperature compensation. The transmitter provides linear current or voltage output and can also be equipped with a relay alarm/control output. All device parameters (preset conductance ranges, analog output range and direction, relay set point, hysteresis, and direction, temperature compensation parameters, etc.) are user-programmable via the RS232 interface and supplied free configuration software. Thanks to its wide measurement range, flexibility, programmability, and reliability, the PHC20 transmitter is very suitable for water treatment and processing applications in the food, pharmaceutical, and many other industries.

Technical specifications Input

Interface

Input type Measurement range Selectable ranges Temperature input Temperature compensation

2-electrode contacting cell 0.1 µS to 100 mS 0.1...10 µS, 10...1000 µS, 1...100 mS Pt1000 0.0...10.0 %/°C, selectable TDS

Accuracy Total measurement error Temperature drift

± 2% from span (incl. non-linearity) 0.06% from span for 1 °C

Analog output 0(4)...20 mA, 0...10 V, reversible 0.025% max. 750 Ω at 20 mA max. 2 kΩ at 10 V 1500 VAC for 1 min

Relay output MOS gate Output function Set point Isolation from input

Power supply 24 VDC ± 10% 4 Vp-p at 50 Hz max. 60 mA 1500 VAC for 1 min

Supply voltage Admissible variations Consumption Isolation from input

0.1A/60V, optically isolated ON/OFF, alarms configurable via interface 1500 VAC for 1 min

Ambient temperature Operating humidity Storage temperature

-10...65 °C 0...85 %RH, non-condensing -20...85 °C

Design and materials Case material Mounting Wiring Dimensions Weight Protection class

plastic on 35 mm DIN rail screw terminals 23x90x58 mm max. 100 g IP20

Ordered separately (see 'Accessories')

PHC20 - G5.G11

Code Feature or option

Code values

G5

Relay output

X - none (2), M - isolated MOS gate, Z - other (specify!)

G11

Analog output

X - none (2), E - 0…20 mA, F - 4…20 mA, K - 0…10 V, Z - other (specify!)

At least one output must be ordered!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code

(2)

RS232, requiring special cable (1) free K2, K2U, K12U

Operating conditions

Output signal Resolution Current load Voltage load Isolation from input

(1)

Interface type Configuration software Interface cable type (1)


electrochemical control equipment Carbon-Dioxide Transmitter PHG ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

Low cost Dual NDIR sensor built-in For HVAC and food processing applications Good accuracy, sensitivity and selectivity Low humidity and temperature dependence Duct mounting variant Local indicator available RS232 interface option

PHG transmitter measures CO2 concentration in in-door atmospheres and converts it into standard current or voltage signal. PHG model uses dual nondispersive infrared (NDIR) carbon-dioxide sensor providing improved accuracy and sensitivity as well as low temperature and humidity dependence. The transmitter can be equipped with local 4-digit LED display and RS232 serial interface. PHG mounting variants include free or duct installation with top or bottom mounted connector. PHG application area includes indoor air control, ventilation, air-conditioning, mushroom control, etc.

Technical specifications Input

Local indicator

Input type Measurement range

Non-dispersive Infrared CO2 cell 0...3000/5000/10000 ppm

Accuracy (1)

Measurement error Temperature dependence Warm-up time Response time (0…80%)

± 2 ppm (0…3000 ppm) at 10…50 °C 10 ppm for 1 °C max. 90 s (at 25 °C) max. 30 s (w/o sintered filter)

Output 0(4)...20 mA 2s 350 Ω at 20 mA 35 ± 2 mA

Output signal Output update Minimum output load Maximum output load Over-scale limit

0…10 V 2s 1 MΩ 17 ± 2 V

Interface Interface type Function Protocol

RS232, 9600 bps CO2 data transmission ASCII, free

Power supply Supply voltage Admissible variations Consumption

15...32 VDC 1 Vp-p at 50 Hz max. 90 mA (150 mA w/ indicator)

Digital display Display resolution Display refresh Accuracy Temperature drift

4 LED indicators, 14 mm 1 ppm 1s 0.2% from span 0.01% from span for 1 °C

Operating conditions Operating temperature Operating humidity Storage temperature

0...50 °C 0...85 %RH, non-condensing -10...60 °C

Design and materials Case material Inlet material Housing dimensions (no connector) Wiring Sensor protection Sintered filter (option) Protection class Mounting Process connection Gas inlet length Weight

ABS/PC plastic POM plastic 80x80x70 mm 4-pin М12 connector (2) plastic cap with polyester filter stainless steel, 75 µm IP65 (excluding gas inlet) free (3) duct (4) none movable flange 130 mm 30 mm max. 250 g max. 350 g

(1)

Including nonlinearity error Straight or angles female part included Radial and axial mounting accessories can be ordered separately (see 'Accessories') (4) Small POM flange DN16.5. (2)

(3)

Ordering code

PHG - G0.G6.G9.G11.G15 - #1.#2

Code Feature or option

Code values free mounting

B - bottom connector, T - top connector

duct mounting

DB - bottom mounted connector, DT - top mounted connector

G0

Case

G6

Input range

03 - 0…3000 ppm, 05 - 0…5000 ppm, 10 - 0…10000 ppm

G9

Serial interface

X - none, A - RS232

G11

Output signal

E - 0…20 mA, F - 4…20 mA, K - 0…10 V, Z - other (specify!)

G15

Connector

C1A - angled M12 connector, C1S - straight M12 connector

#1

Sintered filter

X - none, S - sintered filter mounted

#2

Local indicator

X - none, A - local indicator mounted * contact COMECO

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org


electrochemical control equipment Dissolved-Oxygen Transmitter PHO2 ♦ ♦ ♦ ♦ ♦ ♦ ♦

Input signal from SENSOREX, INGOLD, or compatible probes Temperature compensation input Built-in source for probe polarization voltage Rechargeable battery for probe polarization voltage Standard current or voltage output signal Isolated current output available Polarization-control front-panel switch

PHO2 is an electronic transmitter of dissolved-oxygen measurements. It transforms the signal from a standard INGOLD® or SENSOREX® probe for dissolved O2 or a compatible one, provides the polarization voltage necessary for the INGOLD probe operation, and performs measurement temperature compensation. A built-in rechargeable battery maintains INGOLD probe polarization even in absence of power supply, while a front-panel switch enables turning the polarization voltage off. The PHO2 transducer provides a standard voltage or current output signal that allows connection of any standard control, data logging, or indication device, with its field of application including the biotechnological, chemical, food, etc. industries as well as research.

Technical specifications Input Input signal Dissolved O2 input range Temperature compensation input Polarization voltage

'A' 0...50 mV 0% (pure N2) ... 100% (normal air) internal, 0...50 °C -

'B' 0...67 nA 0% (pure N2) ... 100% (normal air) external NTC 22 kΩ, 0...70 °C 675 mV DC

Accuracy < ± 1% from span < ± 1% from span 0.01% from span for 1 °C < 30 s (at change 0…95%) < ± 0.1 mV

Measurement error Repeatability Temperature drift Response time Polarization voltage (1)

Output Transmission range 0...100%, 0...200%, or 0...300% Output signal 0...20 mA 0…2 V 4...20 mA Input / output isolation (option) 1500 VAC for 1 min none none Minimum output load - 20 kΩ Maximum output load 350 Ω at 20 mA 350 Ω at 20 mA -

Mains supply voltage Isolated low voltage Consumption Polarization rechargeable battery (1) Rechargeable-battery service life (1)

230 VAC or 115 VAC 12…24 V or 24 VAC max. 2 VA 3.6 VDC min. 3 years

Operating conditions Ambient temperature Ambient humidity

0...55 °C 10...85 %RH

Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals Increased front IP (option)

plastic in 90x42 mm panel cut-out plug-in terminals 96x48(front)x107 mm 98 mm max. 400 g IP54 / IP20 IP65

With INGOLD® probes only!

Ordering code

PHO2 - G1.G6.G11'11" - #1.#2

Code Feature or option

Code values

G1

Power supply

A - 230 VAC, B - 115 VAC, Q - 12…24 V, isolated (2), R - 24 VAC

G6

Input

A - from SENSOREX® probe, B - from INGOLD® probe, Z - from other probe (specify probe output!)

G11'

Output signal

E - 0…20 mA, F - 4…20 mA, H - 0…2 V, Z - other (specify!)

G11"

Transmission range

(RANGE) (see table above)

#1

Input / output isolation

X - none, I - isolated output (3)

#2

Increased front protection

X - none, P - IP65 front protection

(2)

Ask for availability! (3) Available only for 4...20 mA output! Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(1)

Power supply


transmitters Analog Signal Isolator TRIL ♦ ♦ ♦ ♦ ♦ ♦

Low cost Passive and active variants 4…20 to 4…20 mA conversion 3750 VAC isolation level Increased input protection Mounting on DIN rail or in IP65 protection box

COMECO's signal isolator TRIL is a compact 2-wire current-to-current transmitter providing optical isolation of 3750 VAC between the input and output current loops. TRIL is available in 2 variants: - passive: an entirely passive device, which does not generate any supply voltages and does not need any additional supply to operate; the input part is powered by the input current loop (4…20 mA), and the output part is powered by the output current loop; - active: uses the energy of the output loop power supply (3-wire connection) to generate an isolated supply voltage for the input loop; provides an increased input over-voltage and over-current protection. TRIL is designed for mounting on a 35 mm DIN rail according to EN 50022, but it can be also enclosed in an IP65 protection box for wall mounting.

Technical specifications Input Input current Operating range Maximum admissible current Loop supply voltage Surge-voltage protection Over-voltage protection Over-current protection

Output Output current Operating range Over-scale limit Loop supply voltage Consumption Maximum line load Output signal at input failure Over-voltage protection Input / output isolation (1) (2) (3)

'0' '1' 4...20 mA 4...20 mA 3.5...21 mA 3.5...21 mA 50 mA 50 mA 10...30 VDC 4...36 VDC (1) 6.8 V (1) 6.8 V (1) 39 V , 90 V (2) none 40 mA none '0' '1' 4...20 mA 4...20 mA 3...22 mA 3...22 mA 32 mA 32 mA 8...32 VDC, 2-wire 24 VDC ± 10%, 3-wire max. 2 W 620 Ω at 24V/20mA 620 Ω at 24V/20mA < 2 mA < 2 mA 39 V (1) 39 V (1) 3750 VAC for 1 min 3750 VAC for 1 min

Accuracy Total measurement error Temperature drift Loop supply influence

0.35% from span 0.03% from span for 1 °C negligible

Operating conditions Ambient temperature Ambient humidity Storage temperature

-20...70 °C 0...95 %RH, non-condensing -40...85 °C

Design and materials Case material Wiring Mounting Dimensions Weight Protection class

on rail 18x90x58 mm 50 g IP20

plastic screw terminals in box (3) 80x80x60 mm 120 g IP65

Surge Zener diode Gas-discharge arrester May be mounted on rail by a special snap-on accessory, which is ordered separately (see 'Accessories').

Ordering code

TRIL - G12

Code Feature or option

0 - passive, 1 - active

Mounting

C - on DIN rail, D - in box IP65 (box included) (3)

COMECO reserves the right of changing specifications without prior notice!

G12

Code values

Variant

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


transmitters Analog Signal Isolator TRIL ♦ ♦ ♦ ♦ ♦ ♦

Low cost Passive and active variants 4…20 to 4…20 mA conversion 3750 VAC isolation level Increased input protection Mounting on DIN rail or in IP65 protection box

COMECO's signal isolator TRIL is a compact 2-wire current-to-current transmitter providing optical isolation of 3750 VAC between the input and output current loops. TRIL is available in 2 variants: - passive: an entirely passive device, which does not generate any supply voltages and does not need any additional supply to operate; the input part is powered by the input current loop (4…20 mA), and the output part is powered by the output current loop; - active: uses the energy of the output loop power supply (3-wire connection) to generate an isolated supply voltage for the input loop; provides an increased input over-voltage and over-current protection. TRIL is designed for mounting on a 35 mm DIN rail according to EN 50022, but it can be also enclosed in an IP65 protection box for wall mounting.

Technical specifications Input Input current Operating range Maximum admissible current Loop supply voltage Surge-voltage protection Over-voltage protection Over-current protection

Output Output current Operating range Over-scale limit Loop supply voltage Consumption Maximum line load Output signal at input failure Over-voltage protection Input / output isolation (1) (2) (3)

'0' '1' 4...20 mA 4...20 mA 3.5...21 mA 3.5...21 mA 50 mA 50 mA 10...30 VDC 4...36 VDC (1) 6.8 V (1) 6.8 V (1) 39 V , 90 V (2) none 40 mA none '0' '1' 4...20 mA 4...20 mA 3...22 mA 3...22 mA 32 mA 32 mA 8...32 VDC, 2-wire 24 VDC ± 10%, 3-wire max. 2 W 620 Ω at 24V/20mA 620 Ω at 24V/20mA < 2 mA < 2 mA 39 V (1) 39 V (1) 3750 VAC for 1 min 3750 VAC for 1 min

Accuracy Total measurement error Temperature drift Loop supply influence

0.35% from span 0.03% from span for 1 °C negligible

Operating conditions Ambient temperature Ambient humidity Storage temperature

-20...70 °C 0...95 %RH, non-condensing -40...85 °C

Design and materials Case material Wiring Mounting Dimensions Weight Protection class

on rail 18x90x58 mm 50 g IP20

plastic screw terminals in box (3) 80x80x60 mm 120 g IP65

Surge Zener diode Gas-discharge arrester May be mounted on rail by a special snap-on accessory, which is ordered separately (see 'Accessories').

Ordering code

TRIL - G12

Code Feature or option

0 - passive, 1 - active

Mounting

C - on DIN rail, D - in box IP65 (box included) (3)

COMECO reserves the right of changing specifications without prior notice!

G12

Code values

Variant

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


transmitters Intelligent Signal Isolator TRI ♦ ♦ ♦ ♦ ♦

Input and output powered by the current loops 4…20 to 4…20 mA or 4…20 to 20…4 mA selectable conversion Up to 4000 VAC isolation level 7 selectable thermocouple linearization blocks Mounting on DIN rail or in IP65 protection box

COMECO's signal isolator TRI is a compact 2-wire current-to-current transmitter providing optical isolation between the input and output current loops. The isolation level is normally 2500 VAC, but can be increased optionally to 4000 VAC. The TRI current isolator is an entirely passive device – it does not generate any supply voltages and does not need any additional supply for operating. The input part is powered by the input current loop (4…20 mA) and the output part is powered by the output current loop. Thanks to the use of high sophisticated electronics for its manufacturing, the TRI isolator offers some special features that can be activated by the user via internal programming jumpers: - direct (4…20 to 4…20 mA) or reversed (4…20 to 20…4 mA) conversion; - "Low" (3 mA) or "High" (22 mA) output status at input failure; - thermocouple non-linear conversions providing temperature linear output. TRI is designed for mounting on a 35 mm DIN rail according to EN50022, but it can be also enclosed in an IP65 protection box for wall mounting.

Technical specifications Input

Isolation

Input current Operating range Maximum admissible current Loop supply voltage Input voltage drop

4...20 mA 3.5...21 mA 50 mA 3...36 VDC less than 2.6 V

Output 4...20 mA or 20...4 mA 3...22 mA 32 mA 8...32 VDC 620 Ω at 24V/20mA 3 mA or 22 mA, selectable

Output current Operating range Over-scale limit Loop supply voltage Maximum line load Output signal at input failure (1)

Conversion Linear conversion direct Linear conversion reversed Non-linear conversions (1) (2)

(selectable) input 4 mA → output 4 mA input 20 mA → output 4 mA 7 selectable thermocouple ranges: 3 "J" and 4 "K"

Input / output isolation Increased isolation (option)

2500 VAC for 1 min 4000 VAC

Accuracy Total measurement error Temperature drift Loop supply influence

0.1% from span 0.01% from span for 1 °C negligible

Operating conditions Ambient temperature Ambient humidity Storage temperature

-20...70 °C 0...95 %RH, non-condensing -35...85 °C

Design and materials Case material Wiring Mounting Dimensions [mm] Weight Protection class

on rail 18x75x60 50 g IP20

plastic screw terminals in box (2) 80x80x60 120 g IP65

Outside the input operating range May be mounted on rail by a special snap-on accessory, which is ordered separately (see 'Accessories').

Ordering code

TRI - G12 - #1

Code Feature or option

Code values

Mounting

C - on DIN rail, D - in box IP65 (box included) (2)

#1

Increased isolation level

X - none (standard isolation rate), HI - 4000 VAC

COMECO reserves the right of changing specifications without prior notice!

G12

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


transmitters Universal Signal Isolator TRIM ♦ ♦ ♦ ♦ ♦ ♦ ♦

Input / output / supply triple isolation Accepts mA, mV, V, or Ω linear signals Positive and negative mA or V output Built-in digital filter Direct and reverse conversion Full digital technology – no analog adjustments DIN-rail case and 11-pin box for rail mounting

COMECO's signal isolator TRIM is an active triple-isolated transmitter with separate isolated power supply with 1000 VAC isolation level. The input part is internally powered and generates 24 VDC excitation voltage for external devices connected to TRIM input (current loops, transmitters, etc.). The input may accept various mA, mV, V (unipolar and bipolar) as well as resistive linear signals. The output part is internally energized and generates standard or custom specified linear current or voltage (positive or negative) signals. Thanks to the use of high sophisticated electronics for its manufacturing, the TRIM isolator offers some special features that can be activated by the user via internal programming jumpers: - direct or reversed conversion; - upscale or downscale output status at input failure; - custom specified non-linear conversions. TRIM is available in a case for mounting on a 35 mm DIN rail according to EN50022 and in a convenient 11-pin box for socket mounting.

Technical specifications Input

Accuracy

Linear current Linear voltage Linear resistive Custom linear (option) Current-input impedance Voltage-input impedance Input isolation

0...5 mA, 0(4)...20 mA 0...50 mV, 0...100 mV, 0...1 V, -1...1 V, 0...2 V, 0...5 V, 0...10 V, -10...10 V 0...1 kΩ min. -10...max. 10 V (1), 0...max. 100 mA (1), 0...100 Ω...100 kΩ (1) max. 10 Ω min. 1 GΩ (1 MΩ for range span > 1.5 V) > 1000 VAC for 1 min

Output Linear current Liner voltage Custom linear (option) Current-output load Voltage-output load Direct or reverse conversion Output signal at input failure Output isolation Excitation voltage (2) (3)

Power supply 12…24 V max. 100 mA > 1000 VAC for 1 min

Supply voltage Consumption Isolation

Operating conditions Ambient temperature Ambient humidity

Design and materials Dimensions [mm] Mounting Maximum weight [g] Protection class Case material Wiring

-20...70 °C 0...95 %RH, non-condensing 'R1'

'R2'

23x90x58 35x78x91 in socket or on rail on rail 180 80 IP20 IP20 plastic plastic screw terminals socket UNDECAL (3)

On request. Specify range additionally! Minimum 50 kΩ for negative output voltage ranges! Ordered separately (see 'Accessories').

Ordering code

TRIM - G0.G6.G11

Code Feature or option

Code values

G0

Case

R1 - for rail mounting, R2 - 11-pin box

G6

Input signal

A - 0…5 mA, B - 0…20 mA, C - 4…20 mA, F - 0…50 mV, G - 0…100 mV, H - 0…1 V, H1 - -1…1 V, I - 0…2 V, J - 0…5 V, K - 0…10 V, K1 - -10…10 V, L - resistance, Z - other

G11

Output signal

B - 0…5 mA, C - 1…5 mA, D - 2…10 mA, E - 0…20 mA, F - 4…20 mA, G - 0…1 V, H - 0…2 V, I - 0…5 V, J - 1…5 V, K - 0…10 V, L - 2…10 V, Z - other

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(1)

0(1)...5 mA, 2...10 mA, 0(4)...20 mA 0...1 V, 0...2 V, 0(1)...5 V, 0(2)...10 V on request (1) max. 620 Ω min. 1 kΩ (2) selectable upscale or downscale, selectable > 1000 VAC for 1 min 24 VDC, max. 30 mA

0.1% from span 0.01% from span for 1 °C negligible

Measurement error Temperature drift Power supply influence


transmitters AC/DC Current Transmitter TRT ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

Low cost 100% 2-wire AC/DC transmission Case for mounting inside current transformers available Reliable and accurate conversion High EMS suppression Input isolation option ZERO and SPAN adjustment In-head and DIN-rail versions

The current-to-current transmitter TRT is designed to convert alternative current signal coming from current transformers into a standard 2-wire current signal, which is more suitable for transmitting. Together with a current transformer, the TRT unit forms an AC/DC current converter suitable to measure big AC currents up to more than 1000 A. The 4...20 mA output can be used for measuring, regulation, and registration in special control systems. The TRT transmitter is based on modern integrated circuits and is a fixed-range transmitter. Its input ranges cover most popular current transformer output signals (0...1 A, 0...5 A) and customer specified inputs as well. TRT is available in a casing for mounting inside a current transformer, in 2 casings for DIN-rail mounting as well as mounted into an IP65 protection box, as the latter 3 versions can be equipped with an optional input isolation. TRT is an easy-to-use, low-cost, and EMSprotected device. Its application area includes power stations, electrical equipment, and electricity production and distribution. This transmitter can also be used as sensor transducer in various industrial control systems and everywhere, where AC to DC current conversion is desirable.

Technical specifications Input

Power supply

Input signal Frequency Input range Other input ranges Input isolation (option) (1)

alternative current 50/60 Hz 0…1 A or 0…5 A 0…max. 10 A internal current transformer

Output Output signal Current limits ZERO and SPAN adjustment Maximum line load

4...20 mA, 2-wire Low = 3 mA, High = 28 mA ± 10%, via trimpots 800 Ω at 24V/20mA

Accuracy Measurement error at 25 °C Non-linearity Temperature drift Supply voltage variation influence

0.5% from span 0.5% from span (up to 1.0% w/ input isolation) 0.1% from span for 1 °C 0.02% from span for 1 V

Mains supply voltage (2) Isolated low voltage (2) Non-isolated low voltage Admissible variations

230 VAC or 115 VAC 12...24 V 8...32 VDC 10% p-p at 50 Hz

Operating conditions Ambient temperature Ambient humidity: - mounted in a transformer - mounted on a rail - mounted in a box

-20...70 °C 0...80 %RH, non-condensing 0...95 %RH, non-condensing 0...95 %RH

Design and materials Mounting Dimensions [mm] Weight Protection, case/terminals Case material Wiring

free in box (3) on rail in socket (4) 43x33x16 80x80x60 35x110x58 35x78x91 110 g 180 g 20 g 90 g IP65 IP20 IP40/20 IP20 plastic plastic plastic plastic screw socket screw plug-in terminals terminals terminals UNDECAL (5)

(1)

Not available for the version for free mounting (G12 = "B")! Only for the version for mounting in socket May be mounted on rail by a special snap-on accessory, which is ordered separately (see 'Accessories'). (4) May be also mounted on a DIN rail (5) Ordered separately (see 'Accessories') (2)

Ordering code

TRT - G1.G6.G12 - #1

Code Feature or option

(6)

Code values

G1

Power supply

D - 8...32 VDC, non-isolated, A - 230 VAC (2), B - 115 VAC (2), Q - 12…24 V, isolated (2)

G6

Input

EQ - 0…1 AAC, ER - 0…5 AAC, EZ - other (6)

G12

Mounting

B - free (bare module), C1 - on DIN rail, C2 - in socket, D - in box IP65 (box included) (3)

#1

Input isolation

X - none, I - input isolation (1)

Specify upper current limit within the range given in the 'Input' table section above.

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(3)


transmitters Analog Load-Cell Transmitter TRW ♦ ♦ ♦ ♦ ♦ ♦

Low cost and small size 10 V excitation voltage 1 mV/V minimum input range Minimum 120 Ω load cell resistance 3-wire current or voltage output High protection class – IP67

With its IP67 cast aluminum enclosure, the TRW analog load-cell transmitter has been specially designed to be used in harsh industrial environments. This model can power a single 120...350 Ω load cell with 10 V bridge excitation voltage. TRW accepts 1, 2, or 3 mV/V input signal and generates a standard linear output signal that can be safely sent over long distances to remote indicators, data loggers, or controllers. ZERO and SPAN adjustments can be performed by the means of built-in potentiometers. TRW is low-priced and can withstand considerable electromagnetic disturbances. It can be a preferable low-cost solution for general-purpose process weighting as well as tension measurement applications.

Technical specifications Input

Accuracy single load cell 10 GΩ 120...350 Ω 1, 2, or 3 mV/V 10 VDC ± 0.05% 10, 20, or 30 mV min. ± 10% low-pass, fixed (≈ 10 Hz)

Input type Input impedance Load cell resistance Input sensitivity Bridge excitation voltage Full-scale input range ZERO and SPAN adjustment Analog filter

Output

0.15% from span 0.01% from span for 1 °C

Power supply Supply voltage Admissible variations

15...35 VDC 10% p-p at 50 Hz

Operating conditions Ambient temperature Ambient humidity

-20...60 °C 0...95 %RH

Design and materials

Output signal Minimum output load Maximum output load Output-error signal (NC) Current limit (1)

Measurement error Temperature drift

4(0)...20 mA 750 Ω at 24V/20 mA open collector, 36V/20mA 24...44 mA

0…10 V 1 MΩ open collector, 36V/20mA max. 42 ± 6 mA

Case material Mounting Wiring Dimensions Weight Protection class

aluminum free (1) screw terminals, 2 PG7 glands 77x82x58 mm (w/o glands) max. 210 g IP67

Radial, axial, and DIN-rail mounting accessories can be ordered separately (see 'Accessories').

Ordering code

TRW - G6.G11

Code Feature or option

Code values

Input

OL1 - 1 mV/V, OL2 - 2 mV/V, OL3 - 3 mV/V

G11

Output signal

E - 0…20 mA, F - 4…20 mA, K - 0…10 V, Z - other (specify!)

COMECO reserves the right of changing specifications without prior notice!

G6

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,




process indicators Low-cost Programmable Display TI08 ♦ ♦ ♦ ♦ ♦ ♦

Lowest cost 5 DIN cases - up to 1/32 DIN 4-digit bright LED indication Universal linear input Up to 2 alarm relays available with pulsed output Fully programmable parameters

TI08 is a cheap programmable process indicator available in 5 DIN cases and designed for wide range of display applications with/without relay alarm. Equipped with a bright 4-digit LED display, this model is especially suitable for measuring and controlling various technological values from -1999 to 9999 with resolution of up to 6000 points. The device may be equipped with up to 2 programmable relays providing ON/OFF control/alarm with or without pulse mode. TI08 accepts various linear input voltage or current signals. The display limits, decimal point position, measurement offset value as well as many other parameters are fully programmable. Thanks to its excellent price-to-performance ratio, TI08 is an exceptionally widely applicable device.

Technical specifications Input Linear voltage 0...10 V Linear voltage 0...5 V (1) Linear current 0(4)...20 mA Custom linear (option) Two-wire external transmitter Decimal point selection

(programmable) -1999...9999, programmable -1999...9999, programmable -1999...9999, programmable -1999...9999, programmable 4...20 mA (2) programmable (up to 2 relay outputs (3))

Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Alarms

5A/250V w/ NO/NC (4) contact 1A/250VAC (5) 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF, pulse mode programmable

Accuracy 0.3% from span 0.02% from span for 1 °C

Measurement error Temperature drift

Operating conditions -10...65 °C 0...85 %RH

Operating temperature Operating humidity

Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage External mains transformer (6) Consumption

230 VAC (1) or 115 VAC (1) 90…250 VAC/DC (1) 12…24 VAC/DC or 24 VAC (1) 12…24 VAC/DC 9(12) VAC max. 1.5 VA

Indication and controls Digital display LEDs Keyboard

Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals)

4 LED indicators 2 LEDs for output state 2 membrane keys, lockable 'B' 'H' 'S' 'L' 'M' 96x96 96x48 48x48 72x36 48x24 panel panel panel panel panel 90x90 90x42 45x45 71x29 46x22 98 56 98 100 42 14 14 20 10 9 250 150 350 200 30 IP54/20 IP54/20 IP54/20 IP54/20 IP54/20 IP65 IP65 IP65 (7) plastic plastic plastic plastic plastic plug-in plug-in screw screw screw

(1)

Not available for case 'M' Provides loop supply voltage - 24 VDC (only w/ isolated power supply) Only one for case 'M' (4) For case 'S' 2nd relay is NO; for case 'L' both relays are NO; for case 'M' relay is 3A/250VAC with NO contact (5) 0.2A/250VAC for cases 'L' and 'M' (6) Ordered separately (see 'Accessories') (7) Ask for availability! (2)

(3)

TI08 - G0.G1.G5G5 - #1.#2

Code Feature or option

(8)

Code values

G0

Case (front size)

B - 96x96 mm, H - 96x48 mm, S - 48x48 mm, L - 72x36 mm, M - 48x24 mm

G1

Power supply

A - 230 VAC (1), B - 115 VAC (1), C - 90…250 V (1), E - 9(12) VAC w/ external transformer (6), P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC (1)

G5

Relay output (3)

X - none, C - relay NO/NC (4), D - SSR, J - for external SSR, M - isolated MOS gate

#1

Increased front protection

X - none, P - IP65 front protection (1,8)

#2

Customer specified input signal

X - none, Z - custom linear signal (specify!)

Not available for case 'S'

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code


process indicators Programmable Trip-alarm Unit TI08-R ♦ ♦ ♦ ♦ ♦ ♦ ♦

Low cost 11-pin box for DIN-rail mounting 3-digit bright LED indication Universal linear input Up to 2 alarm relays available with pulsed output Auxiliary output for powering external transmitters Fully programmable parameters

TI08-R is a cheap programmable process indicator for DIN-rail mounting designed for trip-alarm applications. Equipped with a bright 3-digit LED display, this model is especially suitable for measuring and controlling various technological values from -199 to 999 with resolution of up to 1000 points. The device can have up to 2 programmable relays providing on/off control/alarm with or without pulse mode. TI08-R accepts various linear input voltage or current signals from 2- and 3-wire transmitters that can be powered internally via the auxiliary power supply output. The display-to-input correspondence, decimal point position, measurement offset value as well as many other parameters are fully programmable. Thanks to its excellent price-to-performance ratio, TI08-R is an exceptionally widely applicable device.

Technical specifications Input Linear voltage 0...10 V Linear voltage 0...5 V Linear current 0(4)...20 mA Two-wire external transmitter Decimal point selection

Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Alarms

(programmable) -199...999, programmable -199...999, programmable -199...999, programmable 4...20 mA (1) programmable (up to 2 relay outputs) 5A/250V w/ NO/NC (2) contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF, pulse mode programmable

Accuracy 0.3% from span 0.02% from span for 1 °C

Measurement error Temperature drift

Operating conditions -10...65 °C 0...85 %RH

Operating temperature Operating humidity (1) (2) (3)

Power supply Mains supply voltage Isolated low voltage Non-isolated low voltage External mains transformer (3) Consumption

230 VAC or 115 VAC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC 9(12) VAC max. 1.5 VA

Indication and controls Digital display LEDs Keyboard

3 LED indicators, 10 mm 2 LEDs for output state 3 membrane keys, lockable

Design and materials Case material Mounting Wiring Dimensions Weight Protection, front/terminals

plastic in socket or on 35 mm DIN rail socket UNDECAL (3) 35x78x91 mm 180 g IP44 / IP20

Provides loop supply voltage - 24 VDC (only w/ isolated power supply) NO for the 2nd relay Ordered separately (see 'Accessories')

Ordering code

TI08 - R.G1.G5G5

Code Feature or option

Code values

Power supply

G5

Relay output

X - none, C - relay NO/NC (2), D - SSR, J - for external SSR, M - isolated MOS gate

COMECO reserves the right of changing specifications without prior notice!

G1

A - 230 VAC, B - 115 VAC, E - 9(12) VAC w/ external transformer (3), P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


process indicators Programmable Process Indicator TC660 ♦ ♦ ♦ ♦ ♦ ♦ ♦

20 mm or 32 mm digit height Universal programmable input 2 programmable alarm outputs Programmable digital filter Calibration and self-calibration Isolated current output RS485 serial interface available

TC660 is a multifunctional programmable process indicator with a 4-digit, 20 mm or 32 mm programmable display that provides excellent visibility in many applications. The device has a universal input for the most common thermoresistances, thermocouples, and linear signals. The input has a built-in automatic software compensation of line resistance and cold junction temperature as well as automatic software compensation of temperature drift, and can be calibrated manually. A programmable input filter and various options for access restriction are available. TC660 can also have up to 2 programmable alarm outputs (2 relays or 1 relay and 1 analog output) and can be equipped with an isolated RS485 serial interface. Input Technical

specifications

Pt100 (w=1.385, 1.391); 3-wire Cu100 (w=1.426, 1.428); 3-wire Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" Thermocouple "C" Thermocouple "L - GOST" Linear voltage 0...50 mV (1) Linear current 0...20 mA Linear current 4...20 mA Input type selection Decimal point selection Digital filter Input calibration

Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Operation modes Control algorithms Auto-tuning Alarms Other control features Analog output (3) Serial interface

(programmable) -100...600 °C -50...200 °C 0...1000 °C 0...1300 °C 0...1700 °C 0...1700 °C 100...1800 °C 0...2300 °C 0...600 °C -1999...9999, programmable -1999...9999, programmable -1999...9999, programmable (2) programmable programmable programmable programmable (up to 2 outputs) 5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA manual and automatic ON/OFF, PID-pulse, and PID for motor valves, programmable programmable programmable BUMPLESS and ANTI-WINDUP 4(0)...20 mA or 0...10 V, isolated RS485, isolated

Accuracy 0.3% (4) from span 0.01% from span for 1 °C automatic software automatic software automatic software

Measurement error Temperature drift Self-calibration Cold junction compensation RTD line compensation

Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption

230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 5 VA

Indication and controls 4 LED indicators 2 LEDs for output state 3 membrane keys

Digital display LEDs Keyboard

Operating conditions Operating temperature Operating humidity

Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring

'H' 96x48 panel 90x42 98 20 400 IP54 / IP20 IP65 plastic plug-in terminals

-10...55 °C 0...85 %RH 'D' (5) 144x72 panel 136x66 92 32 600 IP54 / IP20 plastic plug-in terminals

(1)

Other voltage ranges can be obtained by the means of 2 external resistors. Provides loop supply voltage - 24 VDC (only w/ isolated power supply) Instead of 1st relay! If mounted, it can be programmed as control or retransmission! (4) 0.5% for T/Cs "S", "R", "B", and "C" (5) Ask for availability! (3)

Ordering code

TC660 - G0.G1.G5G5.G9'9".G11 - #1

Code Feature or option

(6)

Code values

G0

Case (front size)

H - 96x48 mm, D - 144x72 mm (5)

G1

Power supply

A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

G5

Relay output

X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate

G9'

Serial interface

X - none, B - RS485

G9"

Protocol

A - ASCII, C - ASCII for "PolyMonitor"

G11

Analog output (3)

X - none, E - 0…20 mA, F - 4…20 mA, K - 0…10 V

#1

Increased front protection

X - none, P - IP65 front protection (6)

Available ONLY for case 'H'

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(2)


process indicators Programmable Process Indicator TC67U ♦ ♦ ♦ ♦ ♦ ♦ ♦

Low cost Large LED display up to 45 mm high Universal input for 4 RTDs, 6 T/Cs, and 3 linear types 2 alarm relay outputs Software input line and 'cold junction' correction Self-testing and self-calibration RS485 serial interface available

TC67U is designed for wide range of control applications. It is equipped with a large LED display and 2 programmable relay alarm outputs. TC67U has a universal input accepting signals from Pt100, Pt1000, PTC, 6 thermocouple types as well as linear current and voltage signals from external transmitters. This device also has a built-in circuit for self-testing and self-calibration, manual measurement offset setting, and automatic software compensation of line resistance and cold junction temperature. The display-to-input correspondence (in case of linear input), decimal point position, temperature measurement unit, and offset value are also programmable through the convenient keyboard. Thanks to its large display, universal input, serial interface, and excellent price-to-performance ratio, TC67U is exceptionally widely applicable device.

Technical specifications (programmable)

Pt100 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire PTC (1k at 25 °C); 3-wire PTC (2k at 25 °C); 3-wire Thermocouple "T" Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" Linear voltage 0...10 V Linear current 0(4)...20 mA Custom linear (option) (3) Two-wire external transmitter Manual input offset Input type selection Decimal point selection Temperature measurement unit

Outputs

-100...850 °C -100...600 °C -50...150 °C -50...150 °C -40...400 °C -20...1000 °C -20...1300 °C (1) 0...1700 °C (1) 0...1700 °C (1) 100...1800 °C (1) -1999...9999 (2), programmable -1999...9999 (2), programmable -1999...9999 (2), programmable 4...20 mA (4) programmable programmable programmable °C or °F, programmable (up to 2 relay outputs)

Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Alarms Serial interface

5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF within input range limits programmable RS485, isolated

Accuracy Measurement error Temperature drift Cold junction compensation RTD line compensation

Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption

3 or 4 LED indicators 2 LEDs for output state 3 membrane keys

Digital display LEDs Keyboard

Operating conditions Operating temperature Operating humidity

Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digits Display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals) (4)

(2)

(5)

Ordering code

230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 2 VA

Indication and controls

(1)

Up to 1000 °C for case 'D3' -199...999 for case 'D3' (3) Instead of linear current

0.3% from span 0.02% from span for 1 °C automatic, -10...80 °C automatic, up to 2 х 25 Ω

(6)

'H' 96x48 panel 90x42 98 4 20 400 IP54/20 IP65 (5) plastic plug-in

'D3' 144x72 panel 136x66 92 3 45 600 IP54/20 plastic plug-in

Provides loop supply voltage - 24 VDC (only w/ isolated power supply) Double front panel sealing! Available ONLY for case 'H'

TC67U - G0.G1.G5G5.G9'9" - #1.#2

Code Feature or option

Code values

G0

Case (front size)

H - 96x48 mm, D3 - 144x72 mm w/ 3-digit display, D4 - 144x72 mm w/ 4-digit display

G1

Power supply

A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

G5

Relay output

X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate

G9'

Serial interface

X - none, B - RS485

G9"

Protocol

A - ASCII, C - ASCII for "PolyMonitor"

#1

Increased front protection

X - none, P - IP65 front protection (6)

#2

Customer specified input signal

X - none, Z - custom linear signal (specify!) (3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

-10...65 °C 0...85 %RH 'D4' 144x72 panel 136x66 92 4 32 600 IP54/20 plastic plug-in

COMECO reserves the right of changing specifications without prior notice!

Input


process indicators Programmable Process Indicator TC67U ♦ ♦ ♦ ♦ ♦ ♦ ♦

Low cost Large LED display up to 45 mm high Universal input for 4 RTDs, 6 T/Cs, and 3 linear types 2 alarm relay outputs Software input line and 'cold junction' correction Self-testing and self-calibration RS485 serial interface available

TC67U is designed for wide range of control applications. It is equipped with a large LED display and 2 programmable relay alarm outputs. TC67U has a universal input accepting signals from Pt100, Pt1000, PTC, 6 thermocouple types as well as linear current and voltage signals from external transmitters. This device also has a built-in circuit for self-testing and self-calibration, manual measurement offset setting, and automatic software compensation of line resistance and cold junction temperature. The display-to-input correspondence (in case of linear input), decimal point position, temperature measurement unit, and offset value are also programmable through the convenient keyboard. Thanks to its large display, universal input, serial interface, and excellent price-to-performance ratio, TC67U is exceptionally widely applicable device.

Technical specifications (programmable)

Pt100 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire PTC (1k at 25 °C); 3-wire PTC (2k at 25 °C); 3-wire Thermocouple "T" Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" Linear voltage 0...10 V Linear current 0(4)...20 mA Custom linear (option) (3) Two-wire external transmitter Manual input offset Input type selection Decimal point selection Temperature measurement unit

Outputs

-100...850 °C -100...600 °C -50...150 °C -50...150 °C -40...400 °C -20...1000 °C -20...1300 °C (1) 0...1700 °C (1) 0...1700 °C (1) 100...1800 °C (1) -1999...9999 (2), programmable -1999...9999 (2), programmable -1999...9999 (2), programmable 4...20 mA (4) programmable programmable programmable °C or °F, programmable (up to 2 relay outputs)

Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Alarms Serial interface

5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF within input range limits programmable RS485, isolated

Accuracy Measurement error Temperature drift Cold junction compensation RTD line compensation

Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption

3 or 4 LED indicators 2 LEDs for output state 3 membrane keys

Digital display LEDs Keyboard

Operating conditions Operating temperature Operating humidity

Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digits Display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals) (4)

(2)

(5)

Ordering code

230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 2 VA

Indication and controls

(1)

Up to 1000 °C for case 'D3' -199...999 for case 'D3' (3) Instead of linear current

0.3% from span 0.02% from span for 1 °C automatic, -10...80 °C automatic, up to 2 х 25 Ω

(6)

'H' 96x48 panel 90x42 98 4 20 400 IP54/20 IP65 (5) plastic plug-in

'D3' 144x72 panel 136x66 92 3 45 600 IP54/20 plastic plug-in

Provides loop supply voltage - 24 VDC (only w/ isolated power supply) Double front panel sealing! Available ONLY for case 'H'

TC67U - G0.G1.G5G5.G9'9" - #1.#2

Code Feature or option

Code values

G0

Case (front size)

H - 96x48 mm, D3 - 144x72 mm w/ 3-digit display, D4 - 144x72 mm w/ 4-digit display

G1

Power supply

A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

G5

Relay output

X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate

G9'

Serial interface

X - none, B - RS485

G9"

Protocol

A - ASCII, C - ASCII for "PolyMonitor"

#1

Increased front protection

X - none, P - IP65 front protection (6)

#2

Customer specified input signal

X - none, Z - custom linear signal (specify!) (3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

-10...65 °C 0...85 %RH 'D4' 144x72 panel 136x66 92 4 32 600 IP54/20 plastic plug-in

COMECO reserves the right of changing specifications without prior notice!

Input


process indicators Programmable Process Indicator TC67U ♦ ♦ ♦ ♦ ♦ ♦ ♦

Low cost Large LED display up to 45 mm high Universal input for 4 RTDs, 6 T/Cs, and 3 linear types 2 alarm relay outputs Software input line and 'cold junction' correction Self-testing and self-calibration RS485 serial interface available

TC67U is designed for wide range of control applications. It is equipped with a large LED display and 2 programmable relay alarm outputs. TC67U has a universal input accepting signals from Pt100, Pt1000, PTC, 6 thermocouple types as well as linear current and voltage signals from external transmitters. This device also has a built-in circuit for self-testing and self-calibration, manual measurement offset setting, and automatic software compensation of line resistance and cold junction temperature. The display-to-input correspondence (in case of linear input), decimal point position, temperature measurement unit, and offset value are also programmable through the convenient keyboard. Thanks to its large display, universal input, serial interface, and excellent price-to-performance ratio, TC67U is exceptionally widely applicable device.

Technical specifications (programmable)

Pt100 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire PTC (1k at 25 °C); 3-wire PTC (2k at 25 °C); 3-wire Thermocouple "T" Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" Linear voltage 0...10 V Linear current 0(4)...20 mA Custom linear (option) (3) Two-wire external transmitter Manual input offset Input type selection Decimal point selection Temperature measurement unit

Outputs

-100...850 °C -100...600 °C -50...150 °C -50...150 °C -40...400 °C -20...1000 °C -20...1300 °C (1) 0...1700 °C (1) 0...1700 °C (1) 100...1800 °C (1) -1999...9999 (2), programmable -1999...9999 (2), programmable -1999...9999 (2), programmable 4...20 mA (4) programmable programmable programmable °C or °F, programmable (up to 2 relay outputs)

Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Alarms Serial interface

5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF within input range limits programmable RS485, isolated

Accuracy Measurement error Temperature drift Cold junction compensation RTD line compensation

Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption

3 or 4 LED indicators 2 LEDs for output state 3 membrane keys

Digital display LEDs Keyboard

Operating conditions Operating temperature Operating humidity

Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digits Display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals) (4)

(2)

(5)

Ordering code

230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 2 VA

Indication and controls

(1)

Up to 1000 °C for case 'D3' -199...999 for case 'D3' (3) Instead of linear current

0.3% from span 0.02% from span for 1 °C automatic, -10...80 °C automatic, up to 2 х 25 Ω

(6)

'H' 96x48 panel 90x42 98 4 20 400 IP54/20 IP65 (5) plastic plug-in

'D3' 144x72 panel 136x66 92 3 45 600 IP54/20 plastic plug-in

Provides loop supply voltage - 24 VDC (only w/ isolated power supply) Double front panel sealing! Available ONLY for case 'H'

TC67U - G0.G1.G5G5.G9'9" - #1.#2

Code Feature or option

Code values

G0

Case (front size)

H - 96x48 mm, D3 - 144x72 mm w/ 3-digit display, D4 - 144x72 mm w/ 4-digit display

G1

Power supply

A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

G5

Relay output

X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate

G9'

Serial interface

X - none, B - RS485

G9"

Protocol

A - ASCII, C - ASCII for "PolyMonitor"

#1

Increased front protection

X - none, P - IP65 front protection (6)

#2

Customer specified input signal

X - none, Z - custom linear signal (specify!) (3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

-10...65 °C 0...85 %RH 'D4' 144x72 panel 136x66 92 4 32 600 IP54/20 plastic plug-in

COMECO reserves the right of changing specifications without prior notice!

Input


process indicators 8-channel Programmable Indicator TC800 ♦ ♦ ♦ ♦ ♦

8 inputs, 8 outputs, and 16 alarms 2 displays ─ for measured value and for channel number Programmable ranges and alarms Self-testing and system-failure alarm RS485 serial interface available

The TC800 indicator is designed for multi-point control of technological variables. With its compact design, 8 inputs and outputs, TC800 successfully performs all the tasks of indicating, monitoring, and signaling the level of several channels. With the proper programming, any of the channels may be turned into a 2-or 3-state ON/OFF controller and even into a multistage controller. Motorized actuators may be controlled by using 2 relay outputs. The device input accepts thermoresistances, thermocouples, or standard current and voltage signals. Additional discrete inputs are available for remote channel switching and tampering protection. TC800 performs digital compensation for RTD sensor line resistance as well as thermocouple cold-junction compensation, and constantly monitors sensor and sensor-lead state. A rich set of parameters allows programming every aspect of controller operation and an RS485 serial interface allows network operation or connection to operator station.

Technical specifications (2...8 inputs) Pt10…1000 (w=1.385, 1.391) -100(-200)...200(850) °C (1) Cu50, Cu100 (w=1.426, 1.428) -50(0)...200 °C (1) (1) Other RTD min. -200...max. 850 °C Thermocouple "J" 0...800 °C Thermocouple "K" 0...1200 °C Thermocouple "S" 0...1600 °C Thermocouple "R" 0...1600 °C Thermocouple "B" 200...1800 °C Thermocouple "L" 0...1200 °C Thermocouple "L - GOST" 0...600 °C Thermocouple "E" 0...1000 °C Thermocouple "T" 0...400 °C Thermocouple "U" 0...600 °C (1) Other thermocouple min. 0...max. 2400 °C Linear voltage 0...1/ 2/ 5/ 10 V -999...9999, programmable Linear current 0(4)...20 mA -999...9999, programmable (1) Custom linear voltage; max. 40 V min. -999...max. 9999, programmable Custom linear current; max. 50 mA (1) min. -999...max. 9999, programmable

Accuracy

Discrete inputs

Ambient temperature Ambient humidity

Input signal type Input 1 function Input 2 function

Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Alarms System-failure alarm Serial interface

(up to 2 inputs) contact, TTL, NPN, or PNP remote channel selection ext. programmed parameter protection (up to 9 relay outputs) (2) 3A/250V w/ NO (3) contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA up to 16, programmable activates SPDT EMR output No 9 RS485, isolated (4)

(1)

Measurement error Temperature drift Cold junction compensation RTD line compensation

0.4% from span 0.005% from span for 1 °C ± 1 °C, automatic software software

Power supply Mains supply voltage SMPS voltage Isolated low voltage Consumption

230 VAC or 115 VAC 90…250 V 12…24 V or 24 VAC max. 4 VA

Indication and controls Channel-number display Measured-value display LEDs Keyboard

2 green LED indicators, 14 mm 4 red LED indicators, 14 mm 8 LEDs for output state and 16 LEDs for alarm state 8 membrane keys

Operating conditions

Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals Increased front IP (option)

Custom; specify range within the limits stated. Relay No 9 is for system-failure alarm only (G10)! NO/NC for relay No 1 (4) With ASCII protocol, the outputs may be controlled only through the interface, and with binary protocol – only through the hardware! (2) (3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

-10...65 °C 0...85 %RH plastic in 90x90 mm panel cut-out plug-in terminals 96x96(front)x107 mm 98 mm max. 650 g IP54 / IP20 IP65

COMECO reserves the right of changing specifications without prior notice!

Analog inputs


process indicators

Ordering code

TC800 - G1.G5─G5.G6'6"─G6'6".G7G7.G9'9".G10 - #1

Code Feature or option

Code values

G1

Power supply

A - 230 VAC, B - 115 VAC, C - 90…250 V, Q - 12…24 V, isolated, R - 24 VAC

G5

Relay output

X - none, A - relay NO (3), D - SSR, J - for external SSR, M - isolated MOS gate

G6'

Input signal

G6"

Sensor

B - thermoresistance, C - thermocouple, D - linear, Z - other on request RTD

B - Pt50, D - Pt100, F - Pt500, G - Pt1000, H - Cu50, K - Cu100, Z - other (1)

T/C

B - "B", E - "E", J - "J", K - "K", L - "L", M - "L-GOST", S - "S", R - "R", T - "T", U - "U", Z - other (1)

linear

B - 0…20 mA, C - 4…20 mA, H - 0…1 V, I - 0…2 V, J - 0…5 V, K - 0…10 V, Z - other (1)

Discrete input

X - none, A - contact, E - NPN, F - PNP, G - TTL

G9'

Serial interface

X - none, B - RS485

G9"

Protocol

A - ASCII, B - binary, C - ASCII for "PolyMonitor", D - binary for "PolyMonitor"

G10

System alarm

X - none, S - system-failure alarm relay

#1

Increased front protection

X - none, P - IP65 front protection

COMECO reserves the right of changing specifications without prior notice!

G7

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


process indicators Slim-size Bargraph Indicator TC150 ♦ ♦ ♦ ♦ ♦ ♦ ♦

Low-cost Analog design Current and voltage input signals 24x96 mm DIN-sized front panel 30-dot LED bargraph Moving dot / bar modes available Custom-design bargraph and scale available

TC150 is a slim-sized process indicator for panel mounting with 24x96 mm DIN front size. It accepts linear voltage or current signals at its input and is equipped with a 30-dot vertical LED bargraph, indicating the input value as a percentage of the input range and thereby presenting a convenient 'analog' reading. In combination with a level transmitter, TC150 provides a handy level indication. Moving dot and moving bar modes of the bargraph display as well as custom bargraph design are available. Low priced, TC150 with its useful features and slim front design can be widely applicable for a vast range of industrial solutions.

Technical specifications Input (1)

Power supply

Linear voltage

0…10, 20, 50, or 100 mV, 0…1, 2, 5, or 10 V 0(4)…20 mA min. 0...max. 40 V DC min. 0...max. 100 mA DC

Linear current (2) Custom linear voltage Custom linear current (2)

Accuracy

SMPS voltage Isolated low voltage Non-isolated low voltage Consumption

90…250 VAC/DC 12…24 VAC/DC 12…24 VAC/DC max. 4 VA

Operating conditions Operating temperature Operating humidity

-10...65 °C 0...85 %RH

Design and materials

Resolution Temperature drift

3.33% from span 0.02% from span for 1 °C

Bargraph display Type Scale Mode Color

30 LED dots, 2 mm wide 0…100% or custom design (2) moving dot or moving bar (2) red, green, or yellow

Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals Increased front IP (option)

plastic in 21x93 mm panel cut-out plug-in terminals 24x96(front)x125 mm 120 mm max. 150 g IP54 / IP20 IP65

(1)

Provides loop supply voltage - 24 VDC (only w/ isolated power supply) Specify when ordering! (3) Ask for availability! (2)

Ordering code

TC150 - G1.G2.G6'6" - #1

Code Feature or option

Code values

Power supply

C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated

G2

Bargraph display

D1 - w/ moving dot, D2 - w/ moving bar, Z - custom design (specify!)

G6'6"

Input (1)

DA - 0...5 mA, DB - 0...20 mA, DC - 4...20 mA, DE - 0...10 mV, DF - 0...20 mV, DG - 0...50 mV, DH - 0...1 V, DI - 0...2 V, DJ - 0...5 V, DK - 0...10 V, DZ - other

#1

Increased front protection

X - none, P - IP65 front protection

COMECO reserves the right of changing specifications without prior notice!

G1

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail:

exp


process indicators Programmable Bargraph Display TI250 ♦ ♦ ♦ ♦ ♦ ♦ ♦

Tri-color fully programmable 30-dot LED bargraph 3-digit bright LED indication Universal linear input Up to 2 alarm relays available with pulsed output 48x96 mm DIN-sized front panel Moving dot / bar programmable modes Custom-design bargraph and scale available

TI250 is a versatile and non-expensive combination of TI08 programmable process indicator in 48x96mm DIN case and a fully programmable Tri-color LED bargraph. It is designed for wide range of display applications with/without relay alarm. Equipped with a bright 3-digit LED display, this model is suitable for measuring and controlling various technological values from -199 to 999 with programmable resolution. The device may be also equipped with up to 2 programmable relays providing ON/OFF control/alarm with or without pulse mode. TI250 bargraph display allows user programming of every LED dot color, dot/bar display mode as well as customized scale. Like TI08 the unit accepts various linear input voltage or current signals. Display limits, decimal point position, measurement offset value as well as many other parameters are fully programmable. Thanks to its rich display features and excellent price-to-performance ratio, TI250 can be a very useful and widely applicable device.

Technical specifications Input Linear voltage 0...10 V Linear voltage 0...5 V Linear current 0(4)...20 mA Custom linear (option) Two-wire external transmitter Decimal point selection

Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Alarms

(programmable) -199...999, programmable -199...999, programmable -199...999, programmable -199...999, programmable 4...20 mA (1) programmable (up to 2 relay outputs) 5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF, pulse mode programmable

Digital display Design Measurement accuracy Resolution Temperature drift

3 LED indicators, 10 mm 0.3% from span programmable 0.02% from span for 1 °C

Bargraph display Design Scale Mode Color (2) (3)

Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage External mains transformer (2) Consumption

230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC 9(12) VAC max. 3 VA

Indication and controls LEDs Keyboard

2 LEDs for output state 3 membrane keys, lockable

Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity

-10...65 °C 0...85 %RH -20...65 °C 0...95 %RH, non-condensing

Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals Increased front IP (option)

plastic in 42x90 mm panel cut-out plug-in terminals 48x96(front)x107 mm 98 mm max. 300 g IP54 / IP20 IP65

Provides loop supply voltage - 24 VDC (only w/ isolated power supply) Ordered separately (see 'Accessories') Specify when order!

Ordering code

TI250 - G1.G2.G5G5 - #1.#2

Code Feature or option

Code values

G1

Power supply

A - 230 VAC, B - 115 VAC, C - 90…250 V, E - 9(12) VAC w/ external transformer (2), P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

G2

Bargraph display scale

D - standard (0...100%), Z - custom design (specify!)

G5

Relay output

X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate

#1

Increased front protection

X - none, P - IP65 front protection

#2

Customer specified input signal

X - none, Z - custom linear signal (specify!)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(1)

30 LED dots, 2 mm wide 0…100% or custom design (3) programmable: dot or bar programmable: red, green, or yellow

Power supply


process indicators Bargraph Indicator TC66 ♦ ♦ ♦ ♦ ♦ ♦ ♦

Low-cost 4-digit LED display plus 50-dot bargraph Various input signals Well protected from electromagnetic disturbances Moving dot / bar modes available Auxiliary input for display brightness control Custom-design bargraph and scale available

In addition to the digital display, showing the exact value of the measured variable, the TC66 process indicator is equipped with a LED bargraph, indicating the input value as a percentage of the input range and thereby presenting more convenient 'analog' reading. Two variants of the indicator are available: one with a linear, horizontal bargraph ('D') and one with a bargraph in the shape of a 240-degree arc, which provides a visualization resembling that of a traditional pointer-and-dial gauge ('B'). Moving dot and moving bar modes of the bargraph display as well as custom bargraph design are available. Both TC66 variants feature a customized front-panel tag denoting the range and the measurement unit of the monitored physical quantity. The indicator may also be equipped with an auxiliary DC input for display brightness control. The low-priced, low-maintenance TC66 is widely applicable in boat building, power plants, and other industrial areas.

Technical specifications Input

Power supply

Linear voltage 0…10 mV (1) Linear voltage 0…20 mV (1) Linear voltage 0…50 mV (1) Linear voltage 0…100 mV (1) Linear voltage 0…1 V (1) Linear voltage 0…2 V (1) Linear voltage 0…5 V (1) Linear voltage 0…10 V (1) Linear current 0…5 mA (1) Linear current 0(4)…20 mA (1) Custom linear voltage; max. 40 V (1) Custom linear current; max. 50 mA (1) Decimal point position Display range Brightness control (option) (3)

min. -1999...max. 1999 (2) min. -1999...max. 1999 (2) min. -1999...max. 1999 (2) min. -1999...max. 1999 (2) min. -1999...max. 1999 (2) min. -1999...max. 1999 (2) min. -1999...max. 1999 (2) min. -1999...max. 1999 (2) min. -1999...max. 1999 (2) min. -1999...max. 1999 (2) min. -1999...max. 1999 (2) min. -1999...max. 1999 (2) x1, x0.1, x0.01, x0.001 specified by customer min. 0...max. 24 VDC

Accuracy 0.4% from span 0.02% from span for 1 °C

Measurement error Temperature drift

Indication and controls 4 LED indicators 50 LED dots, 0...100%

Digital display Bargraph display (4)

Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption

230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 4 VA

Operating conditions -10...65 °C 0...85 %RH

Operating temperature Operating humidity

Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digit height [mm] Bargraph shape Maximum weight [g] Protection, front/terminals Case material Wiring

'B'

'D'

96x96 panel 90x90 98 10 240° arc 650 IP54 / IP20 plastic plug-in terminals

144x72 panel 136x66 92 14 horizontal bar 650 IP54 / IP20 plastic plug-in terminals

(1)

Specify lower and upper display limits. Provides loop supply voltage - 24 VDC (only w/ isolated power supply) Specify range within the limits stated. (4) Custom display or/and scale design is also available. Ask!

(2)

Ordering code

TC66 - G0.G1.G2.G3.G6'6" - #1

Code Feature or option

Code values

G0

Case (front size)

B - 96x96 mm, D - 144x72 mm

G1

Power supply

A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

G2

Bargraph display

D1 - w/ moving dot, D2 - w/ moving bar, Z - custom design (specify!)

G3

Resolution

B - 1, C - 0.1, D - 0.01, E - 0.001

(1)

G6'6"

Input

#1

Auxiliary input

DA - 0...5 mA, DB - 0...20 mA, DC - 4...20 mA, DE - 0...10 mV, DF - 0...20 mV, DG - 0...50 mV, DH - 0...1 V, DI - 0...2 V, DJ - 0...5 V, DK - 0...10 V, DZ - other X - none, BC - input for brightness control mounted (3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(3)


process indicators Programmable Bargraph Indicator TC600 ♦ ♦ ♦ ♦ ♦ ♦

4-digit LED display plus 50-dot bargraph Various input signals and nonlinearities Programmable ranges and alarms Programmable relay and linear outputs Serial interface available Self-testing and self-calibration

TC600 is a microprocessor-based programmable process indicator with alarm relay outputs. In addition to the digital display, indicating the measured value, the device features a 50-dot LED bar-graph, showing the input value as a percentage of the input range. A changeable front-panel tag indicates the measurement unit. TC600 accepts standard current or voltage signals as well as signals from various thermoresistances and thermocouples. The device software allows programming display range, alarm value and type, and various nonlinear input-to-display transformations. Besides the relay alarm outputs, the indicator may be equipped with a digital interface and an analog retransmission output. The low price and the rich set of functions make TC600 widely applicable in industry and especially in power plants.

Technical specifications Input

Power supply

Pt50…1000 (w=1.385, 1.391) Cu50, Cu100 (w=1.426, 1.428) Other RTD (1) Thermocouple "J" Thermocouple "K" Thermocouple "S" Other thermocouple (1) Linear voltage 0…10 V Linear current 0(4)…20 mA Custom linear voltage; max. 40 V (1) Custom linear current; max. 50 mA (1) Decimal point selection Digital-display range Bargraph range Nonlinear transformation

-99.9(-200)...199.9(800) °C -50.0...199.9 °C min. -200...max. 1000 °C -100...900 °C 0...1200 °C 0...1600 °C min. -200...max. 2400 °C -1999...9999 (2) -1999...9999 (2) min. -1999...max. 9999 (2) min. -1999...max. 9999 (2) programmable programmable programmable up to 6 conversion modules (up to 2 relay and 1 analog) 5A/250V with NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA programmable 4(0)...20 mA or 0...10 V, isolated RS232 or RS485, isolated

Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Alarm set point Analog retransmission output Serial interface (3)

Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption

Indication and controls Digital display Bargraph display (4) LEDs Keyboard

Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digit height [mm] Bargraph shape Maximum weight [g] Protection, front/terminals Case material Wiring

0.4% from span 0.01% from span for 1 °C hardware, ± 1 °C

Custom; specify range within the limits stated Provides loop supply voltage - 24 VDC (only w/ isolated power supply)

Ordering code

-10...65 °C 0...85 %RH

Ambient temperature Ambient humidity

(3) (4)

'B'

'D'

96x96 panel 90x90 98 9 240° arc 650 IP54 / IP20 plastic plug-in terminals

144x72 panel 136x66 92 14 horizontal bar 650 IP54 / IP20 plastic plug-in terminals

Ask for availability! Custom display or/and scale design is also available. Ask!

TC600 - G0.G1.G5G5.G6'6".G9'9".G11 - #1

Code Feature or option

Code values

Case (front size)

B - 96x96 mm, D - 144x72 mm

G1

Power supply

A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

G5

Relay output

X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate

G6'

Input signal

B - thermoresistance, C - thermocouple, D - linear, Z - other on request

G0

G6"

Sensor

RTD

B - Pt50, D - Pt100, F - Pt500, G - Pt1000, H - Cu50, K - Cu100, Z - other (1)

T/C

J - "J", K - "K", S - "S", Z - other (1)

linear

B - 0…20 mA, C - 4…20 mA, K - 0…10 V, Z - other (1)

G9'

Serial interface

X - none, A - RS232 (3), B - RS485 (3)

G9"

Protocol

A - ASCII, C - ASCII for "PolyMonitor"

G11

Analog retransmission output

X - none, E - 0…20 mA, F - 4…20 mA, K - 0…10 V

#1

Nonlinear trans formation

X - none, HC - horizontal cylinder, LC - lying cylindrical tank, SC - standing cylindrical tank, SN - standing conical tank, SP - spherical tank, QR - square root, Z - other

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(1) (2)

4 LED indicators 50 LED dots 2 LEDs for output state 4 membrane keys

Operating conditions

Accuracy Measurement error Temperature drift Cold junction compensation

230 VAC or 115 VAC 90…250 V 12…24 V or 24 VAC 12…24 V max. 5 VA


process indicators Programmable Bargraph Indicator TC600 ♦ ♦ ♦ ♦ ♦ ♦

4-digit LED display plus 50-dot bargraph Various input signals and nonlinearities Programmable ranges and alarms Programmable relay and linear outputs Serial interface available Self-testing and self-calibration

TC600 is a microprocessor-based programmable process indicator with alarm relay outputs. In addition to the digital display, indicating the measured value, the device features a 50-dot LED bar-graph, showing the input value as a percentage of the input range. A changeable front-panel tag indicates the measurement unit. TC600 accepts standard current or voltage signals as well as signals from various thermoresistances and thermocouples. The device software allows programming display range, alarm value and type, and various nonlinear input-to-display transformations. Besides the relay alarm outputs, the indicator may be equipped with a digital interface and an analog retransmission output. The low price and the rich set of functions make TC600 widely applicable in industry and especially in power plants.

Technical specifications Input

Power supply

Pt50…1000 (w=1.385, 1.391) Cu50, Cu100 (w=1.426, 1.428) Other RTD (1) Thermocouple "J" Thermocouple "K" Thermocouple "S" Other thermocouple (1) Linear voltage 0…10 V Linear current 0(4)…20 mA Custom linear voltage; max. 40 V (1) Custom linear current; max. 50 mA (1) Decimal point selection Digital-display range Bargraph range Nonlinear transformation

-99.9(-200)...199.9(800) °C -50.0...199.9 °C min. -200...max. 1000 °C -100...900 °C 0...1200 °C 0...1600 °C min. -200...max. 2400 °C -1999...9999 (2) -1999...9999 (2) min. -1999...max. 9999 (2) min. -1999...max. 9999 (2) programmable programmable programmable up to 6 conversion modules (up to 2 relay and 1 analog) 5A/250V with NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA programmable 4(0)...20 mA or 0...10 V, isolated RS232 or RS485, isolated

Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Alarm set point Analog retransmission output Serial interface (3)

Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption

Indication and controls Digital display Bargraph display (4) LEDs Keyboard

Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digit height [mm] Bargraph shape Maximum weight [g] Protection, front/terminals Case material Wiring

0.4% from span 0.01% from span for 1 °C hardware, ± 1 °C

Custom; specify range within the limits stated Provides loop supply voltage - 24 VDC (only w/ isolated power supply)

Ordering code

-10...65 °C 0...85 %RH

Ambient temperature Ambient humidity

(3) (4)

'B'

'D'

96x96 panel 90x90 98 9 240° arc 650 IP54 / IP20 plastic plug-in terminals

144x72 panel 136x66 92 14 horizontal bar 650 IP54 / IP20 plastic plug-in terminals

Ask for availability! Custom display or/and scale design is also available. Ask!

TC600 - G0.G1.G5G5.G6'6".G9'9".G11 - #1

Code Feature or option

Code values

G0

Case (front size)

B - 96x96 mm, D - 144x72 mm

G1

Power supply

A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

G5

Relay output

X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate

G6'

Input signal

G6"

Sensor

B - thermoresistance, C - thermocouple, D - linear, Z - other on request RTD

B - Pt50, D - Pt100, F - Pt500, G - Pt1000, H - Cu50, K - Cu100, Z - other (1)

T/C

J - "J", K - "K", S - "S", Z - other (1)

linear

B - 0…20 mA, C - 4…20 mA, K - 0…10 V, Z - other (1)

G9'

Serial interface

X - none, A - RS232 (3), B - RS485 (3)

G9"

Protocol

A - ASCII, C - ASCII for "PolyMonitor"

G11

Analog retransmission output

X - none, E - 0…20 mA, F - 4…20 mA, K - 0…10 V

#1

Nonlinear transformation

X - none, HC - horizontal cylinder, LC - lying cylindrical tank, SC - standing cylindrical tank, SN - standing conical tank, SP - spherical tank, QR - square root, Z - other

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org

COMECO reserves the right of changing specifications without prior notice!

(1) (2)

4 LED indicators 50 LED dots 2 LEDs for output state 4 membrane keys

Operating conditions

Accuracy Measurement error Temperature drift Cold junction compensation

230 VAC or 115 VAC 90…250 V 12…24 V or 24 VAC 12…24 V max. 5 VA


process indicators Loop-powered Indicator TI200 ♦ ♦ ♦ ♦ ♦ ♦ ♦

Panel, in-head, or free mounting IP65 box and Ex housing available 4-digit LCD or LED display Down to 2 mA operating loop current Programmable display ranges and alarms 2 alarm outputs Built-in temperature transmitter available

TI200 is a microprocessor-based programmable process indicator, designed especially to be powered from the input current loop. TI200 is equipped with a fully programmable -1999...9999 LCD or LED display with programmable point position and digital filter as well as with a 2-key (hidden) keyboard. Two alarm limits with programmable parameters – set point, hysteresis, direction, dead time, etc – control 2 alarm outputs (polarized relay type or open collector type, which can be used to control external relays). Five different housing types are available: − plastic case for panel mounting with 96x96 mm DIN front size; − plastic case for panel mounting with 96x48 mm DIN front size; − plastic box with IP65 protection class and 80x80 mm front size; − housing for mounting into sensor protection head type "DW" or "DHW"; − housing for mounting into sensor protection head type "EGW". The IP65-box housing allows a standard in-head transmitter to be incorporated inside the box so TI200 can be used as a temperature or level transmitter with local programmable display. The low price, alarm features, and flexibility make TI200 widely applicable in industry and especially when loop current transmission is measured.

Technical specifications Input

Indication and controls

Input type Operating range Measurement range Display range Display-to-input correspondence Decimal point selection

Outputs Non-isolated transistor gate Polarized relay Control algorithm Alarms

loop supply DC current 3...22 mA 4...20 mA min. -1999...max. 9999 programmable programmable (set of 2 alarm outputs) open collector, 100mA/40V 5A/250V w/ NO contact ON/OFF programmable

Accuracy ± 0.05% from span ± 1 digit within measurement error 0.025% from span for 1 °C

Measurement error Non-linearity Temperature drift

Power supply 4...36 VDC 2...50 mA

Loop supply voltage Loop supply current

4 LCD (plus backlight), 13 mm or 4 LED indicators, 14 mm 2 (hidden) keys

Digital display Keyboard

Operating conditions -10...65 °C 0...85 %RH (1)

Operating temperature Operating humidity

Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals)

'B'

'H'

'Y'

'Z1'

'Z2'

96x96 96x48 80x80 ø63 ø73 panel panel free (2) in head (3) in head 90x90 90x42 98 23 60 98 23 200 60 200 300 60 IP65 IP65 IP54/20 IP54/20 IP68 (4) IP65 IP65 plastic plastic plastic aluminum aluminum spring plug-in plug-in screw spring

(1)

0...95 %RH for case 'Y' Radial, axial, and DIN-rail mounting accessories for 80x80x60 mm box can be ordered separately (see 'Accessories') May be mounted in different, separately ordered Ex housings for field applications (see 'Accessories') (4) Ask for availability! (2)

Ordering code

TI200 - G0.G2.G5 - #1.#2.#3

Code Feature or option

Code values

G0

Case

B - for panel mounting, 96x96 mm, H - for panel mounting, 96x48 mm, Y - box IP65, Z1 - for mounting in head type "DW" or "DHW" (3), Z2 - for mounting in head type "EGW" (3)

G2

Display

A - LCD, B - LED, T - LCD + backlight

G5

Relay outputs (set of 2 alarm outputs)

X - none, A - relays NO, E - open collectors NPN, F - open collectors PNP

#1

Increased front protection

X - none, P - IP65 front protection (5)

#2

Temperature transmitter

X - none, TT - built-in temperature transmitter (6)

#3

Mounting kit

X - none, E - kit for mounting in Ex housing (7)

(5)

Not available for cases 'Y', 'Z1', and 'Z2'. Ask for case 'B'! Available ONLY for case 'Y'! Specify exact transmitter type and specifications separately. (7) Only for cases 'Z1' (for mounting in instrument housing EX) and 'Z2' (for mounting in head type "EGW") (6)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(3)


process indicators Loop-powered Indicator TI200 ♦ ♦ ♦ ♦ ♦ ♦ ♦

Panel, in-head, or free mounting IP65 box and Ex housing available 4-digit LCD or LED display Down to 2 mA operating loop current Programmable display ranges and alarms 2 alarm outputs Built-in temperature transmitter available

TI200 is a microprocessor-based programmable process indicator, designed especially to be powered from the input current loop. TI200 is equipped with a fully programmable -1999...9999 LCD or LED display with programmable point position and digital filter as well as with a 2-key (hidden) keyboard. Two alarm limits with programmable parameters – set point, hysteresis, direction, dead time, etc – control 2 alarm outputs (polarized relay type or open collector type, which can be used to control external relays). Five different housing types are available: − plastic case for panel mounting with 96x96 mm DIN front size; − plastic case for panel mounting with 96x48 mm DIN front size; − plastic box with IP65 protection class and 80x80 mm front size; − housing for mounting into sensor protection head type "DW" or "DHW"; − housing for mounting into sensor protection head type "EGW". The IP65-box housing allows a standard in-head transmitter to be incorporated inside the box so TI200 can be used as a temperature or level transmitter with local programmable display. The low price, alarm features, and flexibility make TI200 widely applicable in industry and especially when loop current transmission is measured.

Technical specifications Input

Indication and controls

Input type Operating range Measurement range Display range Display-to-input correspondence Decimal point selection

Outputs Non-isolated transistor gate Polarized relay Control algorithm Alarms

loop supply DC current 3...22 mA 4...20 mA min. -1999...max. 9999 programmable programmable (set of 2 alarm outputs) open collector, 100mA/40V 5A/250V w/ NO contact ON/OFF programmable

Accuracy ± 0.05% from span ± 1 digit within measurement error 0.025% from span for 1 °C

Measurement error Non-linearity Temperature drift

Power supply 4...36 VDC 2...50 mA

Loop supply voltage Loop supply current

4 LCD (plus backlight), 13 mm or 4 LED indicators, 14 mm 2 (hidden) keys

Digital display Keyboard

Operating conditions -10...65 °C 0...85 %RH (1)

Operating temperature Operating humidity

Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals)

'B'

'H'

'Y'

'Z1'

'Z2'

96x96 96x48 80x80 ø63 ø73 panel panel free (2) in head (3) in head 90x90 90x42 98 23 60 98 23 200 60 200 300 60 IP65 IP65 IP54/20 IP54/20 IP68 (4) IP65 IP65 plastic plastic plastic aluminum aluminum spring plug-in plug-in screw spring

(1)

0...95 %RH for case 'Y' Radial, axial, and DIN-rail mounting accessories for 80x80x60 mm box can be ordered separately (see 'Accessories') May be mounted in different, separately ordered Ex housings for field applications (see 'Accessories') (4) Ask for availability! (2)

Ordering code

TI200 - G0.G2.G5 - #1.#2.#3

Code Feature or option

Code values

G0

Case

B - for panel mounting, 96x96 mm, H - for panel mounting, 96x48 mm, Y - box IP65, Z1 - for mounting in head type "DW" or "DHW" (3), Z2 - for mounting in head type "EGW" (3)

G2

Display

A - LCD, B - LED, T - LCD + backlight

G5

Relay outputs (set of 2 alarm outputs)

X - none, A - relays NO, E - open collectors NPN, F - open collectors PNP

#1

Increased front protection

X - none, P - IP65 front protection (5)

#2

Temperature transmitter

X - none, TT - built-in temperature transmitter (6)

#3

Mounting kit

X - none, E - kit for mounting in Ex housing (7)

(5)

Not available for cases 'Y', 'Z1', and 'Z2'. Ask for case 'B'! Available ONLY for case 'Y'! Specify exact transmitter type and specifications separately. (7) Only for cases 'Z1' (for mounting in instrument housing EX) and 'Z2' (for mounting in head type "EGW") (6)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(3)


process indicators Loop-powered Indicator TI200 ♦ ♦ ♦ ♦ ♦ ♦ ♦

Panel, in-head, or free mounting IP65 box and Ex housing available 4-digit LCD or LED display Down to 2 mA operating loop current Programmable display ranges and alarms 2 alarm outputs Built-in temperature transmitter available

TI200 is a microprocessor-based programmable process indicator, designed especially to be powered from the input current loop. TI200 is equipped with a fully programmable -1999...9999 LCD or LED display with programmable point position and digital filter as well as with a 2-key (hidden) keyboard. Two alarm limits with programmable parameters – set point, hysteresis, direction, dead time, etc – control 2 alarm outputs (polarized relay type or open collector type, which can be used to control external relays). Five different housing types are available: − plastic case for panel mounting with 96x96 mm DIN front size; − plastic case for panel mounting with 96x48 mm DIN front size; − plastic box with IP65 protection class and 80x80 mm front size; − housing for mounting into sensor protection head type "DW" or "DHW"; − housing for mounting into sensor protection head type "EGW". The IP65-box housing allows a standard in-head transmitter to be incorporated inside the box so TI200 can be used as a temperature or level transmitter with local programmable display. The low price, alarm features, and flexibility make TI200 widely applicable in industry and especially when loop current transmission is measured.

Technical specifications Input

Indication and controls

Input type Operating range Measurement range Display range Display-to-input correspondence Decimal point selection

Outputs Non-isolated transistor gate Polarized relay Control algorithm Alarms

loop supply DC current 3...22 mA 4...20 mA min. -1999...max. 9999 programmable programmable (set of 2 alarm outputs) open collector, 100mA/40V 5A/250V w/ NO contact ON/OFF programmable

Accuracy ± 0.05% from span ± 1 digit within measurement error 0.025% from span for 1 °C

Measurement error Non-linearity Temperature drift

Power supply 4...36 VDC 2...50 mA

Loop supply voltage Loop supply current

4 LCD (plus backlight), 13 mm or 4 LED indicators, 14 mm 2 (hidden) keys

Digital display Keyboard

Operating conditions -10...65 °C 0...85 %RH (1)

Operating temperature Operating humidity

Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals)

'B'

'H'

'Y'

'Z1'

'Z2'

96x96 96x48 80x80 ø63 ø73 panel panel free (2) in head (3) in head 90x90 90x42 98 23 60 98 23 200 60 200 300 60 IP65 IP65 IP54/20 IP54/20 IP68 (4) IP65 IP65 plastic plastic plastic aluminum aluminum spring plug-in plug-in screw spring

(1)

0...95 %RH for case 'Y' Radial, axial, and DIN-rail mounting accessories for 80x80x60 mm box can be ordered separately (see 'Accessories') May be mounted in different, separately ordered Ex housings for field applications (see 'Accessories') (4) Ask for availability! (2)

Ordering code

TI200 - G0.G2.G5 - #1.#2.#3

Code Feature or option

Code values

G0

Case

B - for panel mounting, 96x96 mm, H - for panel mounting, 96x48 mm, Y - box IP65, Z1 - for mounting in head type "DW" or "DHW" (3), Z2 - for mounting in head type "EGW" (3)

G2

Display

A - LCD, B - LED, T - LCD + backlight

G5

Relay outputs (set of 2 alarm outputs)

X - none, A - relays NO, E - open collectors NPN, F - open collectors PNP

#1

Increased front protection

X - none, P - IP65 front protection (5)

#2

Temperature transmitter

X - none, TT - built-in temperature transmitter (6)

#3

Mounting kit

X - none, E - kit for mounting in Ex housing (7)

(5)

Not available for cases 'Y', 'Z1', and 'Z2'. Ask for case 'B'! Available ONLY for case 'Y'! Specify exact transmitter type and specifications separately. (7) Only for cases 'Z1' (for mounting in instrument housing EX) and 'Z2' (for mounting in head type "EGW") (6)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(3)


process indicators Battery-Powered Thermometer TIB100 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

Operates with TSEC temperature probes Direct in-process mounting All stainless steel design 4-digit 18 mm LCD display Captures minimum and maximum readings Powered by 2 AA batteries 20000 hours average battery life Programmable display ranges and alarms User calibration available Selectable temperature units

COMECO's TIB100 is a digital temperature indicator, designed for direct control over temperature processes when coupled with a TSEC or other compatible temperature probe. This model combines the power supply independence of the bimetallic/gas thermometers and the advantages of the digital temperature measuring instruments. TIB100 is a programmable device and allows current, minimum, and maximum temperature readings, alarm settings, unit selection, and user calibration.

Technical specifications Input

Power supply Pt100 (1), Pt500 (1), Pt1000 min. -50.0...max. 600 °C (min. -58.0...max. 1112.0 °F)

Input (sensor) type Measurement range

Accuracy Display measurement error Non-linearity Hysteresis Repeatability Temperature drift

≤ ± 0.3% of span within measurement error within measurement error within measurement error 0.005% from span for 1 °C

Indication and controls 4-digit LCD, 18 mm 0.1 or 1 °C, programmable on/off, °C/°F/K, min/max, auto off 3 membrane keys through the keyboard 2 programmable alarms on display

Digital display Display resolution Display functions Keyboard Device calibration Alarms

Supply voltage Battery life Battery state control Auto-power-off time

3 V from 2 batteries AA 1.5 V up to 20000 h (2) automatic 0...100 min, programmable

Operating conditions -10...50 °C 0...85 %RH

Ambient temperature Ambient humidity

Design and materials Case material Mounting Probe connection Dimensions Weight Protection class

stainless steel on probe top (3) G3/8", 3/8" NPT, G1/2", 1/2" NPT, M16x1.5, M18x1.5, or welding (4) axial: approx. ø100x50 mm; radial: approx. 100x120x35 mm max. 700 g IP65 (NEMA 4X)

(1)

Ask for availability! Depending on battery type, sensor, and operating mode Order separately! Suitable for assembly are temperature probes type TSEC (see 'Temperature Probes'). (4) Available only when an axial mounted probe is ordered. (2)

(3)

TIB100 - G1.G6'6".G12'12"

Code Feature or option

(5)

Code values

G1

Power supply

X - none (5), G - long-life batteries

G6'6"

Input

BD - Pt100 (1), BF - Pt500 (1), BG - Pt1000

G12'

Probe connection

Q0 - M16x1.5, Q1 - M18x1.5, Q3 - G3/8", Q4 - G1/2", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Uxx - female thread (xx - same as for Qxx), W - welding (4), Z - other (specify!)

G12"

Probe position

A - axial, R - radial underneath, RU - radial on top, RL - radial on the left, RR - radial on the right

The device is supplied without batteries.

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code


process controllers Temperature Controller TC48 ♦ ♦ ♦ ♦ ♦ ♦

Low price 48x48 DIN-sized front panel Thermocouple or Pt100 RTD input Independent set-point observation Sensor break indication Panel, DIN-rail, and in-socket mounting

The TC48 temperature controller has no temperature value indication and thus is applicable in cases, in which the low price is one of the major requirements, especially in food industry and household applications. With its 48x48 mm DIN-sized front panel, TC48 is best suited for applications, in which small size is important too. The device works with either an RTD temperature sensor or a thermocouple type "J" or "K" and can be used for controlling various temperature processes and driving electrical actuators by the means of a relay control output and through ON/OFF algorithm. A potentiometer and a dial on the front panel enable easy set-point adjustment, and a red LED – a clear sensor break indication. The controller can be mounted on a panel, on a rail, and in a socket. Inexpensive, compact, and easy-to-use, the TC48 temperature controller is one versatile general-purpose control device.

Technical specifications Input

Indication and controls 0...100 °C, 0...200 °C, 0...400 °C (1) 0...100 °C, 0...200 °C, 0...400 °C, 0...800 °C (1) 0...400 °C, 0...800 °C, 0...1000 °C, 0...1200 °C (1)

Pt100 (w=1.385); 3-wire Thermocouple "J" Thermocouple "K"

LEDs Front-panel potentiometer Front-panel trimmer potentiometer

LED for relay state, LED for sensor break for set-point adjustment for hysteresis adjustment

Output Relay electromechanical Solid state relay (2) MOS gate (2) Output for external SSR Control algorithm Set point

5A/250V w/ NO/NC or NO contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF within input range limits

Accuracy Measurement error Temperature drift Cold junction compensation

0.5% from span 0.007% from span for 1 °C ± 1 °C

Power supply 230 VAC or 115 VAC 24 VAC max. 3 VA

Mains supply voltage Isolated low voltage (2) Consumption (2) (3)

-10...65 °C 0...85 %RH

Operating temperature Operating humidity

Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals

plastic in 45x45 mm panel cut-out or on 35 mm DIN rail socket (3) OCTAL or UNDECAL 48x48(front)x95 mm 103 mm (w/ socket) max. 250 g IP40 / IP20

Specify range when ordering. Ask for availability! Ordered separately (see 'Accessories')

Ordering code

TC48 - G1.G5.G6'6"

Code Feature or option

Code values

G1

Power supply

A - 230 VAC, B - 115 VAC, R - 24 VAC (2)

G5

Relay output

X - none, C - relay NO/NC, D - SSR (2), J - for external SSR, M - isolated MOS gate (2)

G6'6"

Input

(1)

BD - Pt100, CJ - thermocouple "J", CK - thermocouple "K"

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(1)

Operating conditions


process controllers All-purpose Analog Controller TC56 ♦ ♦ ♦ ♦

Very good EMI protection User-friendly controls Analog retransmission output 4-digit LED display

TC56 is an electronic analog controller with very good protection against electromagnetic disturbances, used for automatic control of various processes through relay outputs employing ON/OFF control algorithm. The device can operate with a number of input signal types – thermoresistive, thermoelectrical, or standard signals from relative humidity, pressure, flow, etc. transmitters – at that providing supply for input signal transmitters. In addition to the 2 control or alarm relay outputs, the TC56 controller can be equipped with an analog retransmission output that generates standard signal to external chart recorders, controllers, and indicators.

Technical specifications Input

Accuracy

Pt46 (GOST) Pt50 (w=1.385, 1.391) Pt100 (w=1.385, 1.391) Pt500 (w=1.385) Pt1000 (w=1.385) Cu100 (w=1.426, 1.428) Cu50 (w=1.426, 1.428) Cu53 (GOST) Other RTD (1) Thermocouple "J" Thermocouple "K" Linear voltage 0…1/ 2 / 5/ 10 V Linear current 0…5 mA Linear current 0(4)…20 mA Custom linear voltage; max. 10 V Custom linear current; max. 50 mA

-50...199.9(600) °C -50...199.9(600) °C -50...199.9(600) °C -50...199.9(600) °C -50...199.9(600) °C -50...199.9(200) °C -50...199.9(200) °C -50...199.9(200) °C min. -99...max. 600 °C 0...700 °C 0...700(1200) °C -199.9(1999)...199.9(1999) (2,3) -199.9(1999)...199.9(1999) (2,3) -199.9(1999)...199.9(1999) (2,3) min. -1999...max. 1999 (2,3) min. -1999...max. 1999 (2,3) (up to 3 outputs) 5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF within input range limits 2 control or 1 control and 1 alarm 0(4)...20 mA or 0...10 V none

Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Relay function Analog retransmission output Isolation

0.5% from span 0.007% from span for 1 °C automatic hardware, ± 1 °C

Measurement error Temperature drift Cold junction compensation

Power supply 230 VAC or 115 VAC 24 VAC max. 4 VA

Mains supply voltage Isolated low voltage Consumption

Indication and controls Digital display LEDs Multi-turn potentiometer Front-panel trimmer Case-side trimmers

4 LED indicators, 14 mm 2 LEDs for relay-output state for set-point adjustment (4) for hysteresis and dead-band adjustment for alarm-limit adjustment

Operating conditions -10...65 °C 0...85 %RH

Operating temperature Operating humidity

Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals

plastic on 90x42 mm panel cut-out plug-in terminals 96x48(front)x107 mm 98 mm max. 400 g IP40 / IP20

(1)

Custom; specify range within the limits stated Specify lower and upper display limits Provides loop supply voltage - 24 VDC (4) Displayed while the set-point button is pressed (2) (3)

TC56 - G1.G3.G5G5.G6'6".G10.G11

Code Feature or option

Code values

G1

Power supply

A - 230 VAC, B - 115 VAC, R - 24 VAC

G3

Resolution

B - 1, C - 0.1

G5

Relay output

X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate

G6'

Input signal

B - thermoresistance, C - thermocouple, D - linear A - Pt46, B - Pt50, C - Pt50, D - Pt100, E - Pt100, F - Pt500, G - Pt1000, H - Cu50, I - Cu50, J - Cu53, K - Cu100, L - Cu100, Z - other (1)

RTD G6"

Sensor

T/C linear

J - "J", K - "K" (2)

A - 0...5 mA, B - 0...20 mA, C - 4...20 mA, H - 0...1 V, I - 0...2 V, J - 0...5 V, K - 0...10 V, Z - other

G10

Alarm

X - none, A - absolute upper, B - absolute lower, C - absolute mixed, D - relative above set point, E - relative below set point

G11

Analog retransmission output

X - none, E - 0…20 mA, F - 4…20 mA, K - 0…10 V, Z - other

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code


process controllers Programmable Controller RT28U ♦ ♦ ♦ ♦ ♦ ♦

Low cost 3-digit bright LED display 4 DIN cases Universal input for 4 RTDs, 6 T/Cs, and 4 linear types Keyboard or encoder adjustment controls RS485 serial interface available

RT28U is designed for wide range of applications. It is equipped with a 3-digit LED display, a universal input for Pt100, Pt1000, PTC, 6 thermocouple types as well as for linear current, voltage, and resistive signals from external transmitters and can have up to 2 programmable relay control/alarm outputs. RT28U can be ordered with either keyboard, or unique rotating encoder for set-point adjustment and programming. All modifications have a built-in circuit for self-testing and self-calibration, manual measurement offset setting, and automatic software compensation of line resistance and cold junction temperature. The display-toinput correspondence (in case of linear input), decimal point position, temperature measurement unit, and offset value are also programmable. Thanks to its universal input, the available various enclosures, serial interface, and excellent price-to-performance ratio, RT28U is an exceptionally widely applicable device.

Technical specifications (programmable)

Pt100 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire PTC (1k at 25 °C); 3-wire PTC (2k at 25 °C); 3-wire Thermocouple "T" Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" Linear voltage 0...10 V Linear current 0(4)...20 mA Linear resistive 0...1 kΩ Custom linear (option) (1) Two-wire external transmitter Manual input offset Input type selection Decimal point selection Temperature measurement unit

Outputs

-100...850 °C -100...600 °C -50...150 °C -50...150 °C -40...400 °C -20...999 °C -20...999 °C 0...999 °C 0...999 °C 100...999 °C -199...999, programmable -199...999, programmable -199...999, programmable -199...999, programmable 4...20 mA (2) programmable programmable programmable °C or °F, programmable (up to 2 relay outputs)

Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Alarms Serial interface

5A/250V w/ NO/NC or NO (3) contact 1A/250VAC (4) 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF within input range limits programmable RS485, isolated

(1)

Instead of linear current Provides loop supply voltage - 24 VDC (only w/ isolated power supply). (3) For case 'S' w/ SMPS, 1st relay is NO; for case 'L' and case 'S' w/ serial interface, 2nd relay is NO. (4) 0.2A/250VAC for case 'L' (5) 0.5% for T/Cs "S", "R", and "B" (2)

Ordering code

Accuracy 0.3% (5) from span 0.02% from span for 1 °C automatic, -10...80 °C automatic, up to 2 х 25 Ω

Measurement error Temperature drift Cold junction compensation RTD line compensation

Power supply Mains supply voltage (6) SMPS voltage Isolated low voltage Non-isolated low voltage External mains transformer (7) Consumption

230 VAC or 115 VAC 90…250 V 12…24 V or 24 VAC 12…24 V 9(12) VAC max. 1.5 VA

Indication and controls Digital display LEDs Controls

3 LED indicators 2 LEDs for output state keyboard w/ 3 keys or rotary encoder (8)

Operating conditions Ambient temperature Ambient humidity

Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals)

'B' 96x96 panel 90x90 98 20 350 IP54/20 IP65 (9) plastic plug-in

'H' / 'V' 96x48 panel 90x42 98 14 300 IP54/20 IP65 plastic plug-in

-10...65 °C 0...85 %RH 'S' 'L' 48x48 72x36 panel panel 45x45 71x29 56 100 14 10 150 200 IP54/20 IP54/20 IP65 plastic plastic screw screw

(6)

Not available for case 'L'. Ordered separately (see 'Accessories') Available ONLY for cases 'H', 'V', and 'B'. (9) Ask for availability! (10) Not available for case 'S'. (7)

(8)

RT28U - G0.G1.G4.G5G5.G9'9" - #1.#2

Code Feature or option

Code values

G0

Case (front size)

B - 96x96 mm, H - 96x48 mm, V - 48x96 mm, S - 48x48 mm, L - 72x36 mm

G1

Power supply

A - 230 VAC (6), B - 115 VAC (6), C - 90…250 V, E - 9(12) VAC w/ external transformer (7), P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

G4

Adjustment controls

A - keyboard, H - rotary encoder (8)

G5

Relay output

X - none, A - relay NO (3), C - relay NO/NC (3), D - SSR, J - for external SSR, M - isolated MOS gate

G9'

Serial interface

X - none, B - RS485

G9"

Protocol

A - ASCII, C - ASCII for "PolyMonitor"

#1

Increased front protection

X - none, P - IP65 front protection (10)

#2

Customer specified input signal

X - none, Z - custom linear signal (specify!) (1)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org

COMECO reserves the right of changing specifications without prior notice!

Input


process controllers Programmable Controller RT28U-R ♦ ♦ ♦ ♦ ♦

Low cost DIN-rail case and 11-pin box for rail mounting 3-digit bright LED display Universal input for 4 RTDs, 6 T/Cs, and 4 linear types RS485 serial interface available

RT28U-R is a modification of RT28U for rail mounting. It is equipped with a 3-digit LED display, a universal input for Pt100, Pt1000, PTC, 6 thermocouple types as well as for linear current, voltage, and resistive signals from external transmitters and can have up to 2 programmable relay control/alarm outputs. The device has a built-in circuit for self-testing and self-calibration, manual measurement offset setting, and automatic software compensation of line resistance and cold junction temperature. The display-to-input correspondence (in case of linear input), decimal point position, temperature measurement unit, and offset value are also programmable. Thanks to its universal input, serial interface, and excellent price-to-performance ratio, RT28U-R is a widely applicable device.

Technical specifications Input Pt100 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire PTC (1k at 25 °C); 3-wire PTC (2k at 25 °C); 3-wire Thermocouple "T" Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" Linear voltage 0...10 V Linear current 0(4)...20 mA Linear resistive 0...1 kΩ Custom linear (option) (1) Two-wire external transmitter Manual input offset Input type selection Decimal point selection Temperature measurement unit

Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Alarms Serial interface (4)

(programmable) -100...850 °C -100...600 °C -50...150 °C -50...150 °C -40...400 °C -20...999 °C -20...999 °C 0...999 °C 0...999 °C 100...999 °C -199...999, programmable -199...999, programmable -199...999, programmable -199...999, programmable 4...20 mA (2) programmable programmable programmable °C or °F, programmable (up to 2 relay outputs) 5A/250V w/ NO/NC or NO (3) contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF within input range limits programmable RS485, isolated

Accuracy 0.3% (5) from span 0.02% from span for 1 °C automatic, -10...80 °C automatic, up to 2 х 25 Ω

Measurement error Temperature drift Cold junction compensation RTD line compensation

Power supply Mains supply voltage Isolated low voltage Non-isolated low voltage External mains transformer (6) Consumption

230 VAC or 115 VAC 12…24 V or 24 VAC 12…24 V 9(12) VAC max. 1.5 VA

Indication and controls 3 LED indicators 2 LEDs for output state 3 membrane keys

Digital display LEDs Keyboard

Operating conditions -10...65 °C 0...85 %RH

Ambient temperature Ambient humidity

Design and materials Dimensions [mm] Mounting Display digit height [mm] Maximum weight [g] Protection, front/terminals Case material Wiring

'R1'

'R2'

70x110x58 on rail 14 300 IP20 plastic screw terminals

35x78x91 in socket or on rail 10 200 IP44 / IP20 plastic socket UNDECAL (6)

(1)

Instead of linear current Provides loop supply voltage - 24 VDC (only w/ isolated power supply). NO/NC for case 'R1'; NO for case 'R2' (4) Not available for case 'R2'. (5) 0.5% for T/Cs "S", "R", and "B" (6) Ordered separately (see 'Accessories') (2)

Ordering code

RT28U - G0.G1.G5G5.G9'9" - #1

Code Feature or option

Code values

G0

Case

R1 - for rail mounting, R2 - 11-pin box

G1

Power supply

A - 230 VAC, B - 115 VAC, E - 9(12) VAC w/ external transformer (6), P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

G5

Relay output

X - none, A - relay NO (3), C - relay NO/NC (3), D - SSR, J - for external SSR, M - isolated MOS gate (4)

G9'

Serial interface

G9"

Protocol

A - ASCII, C - ASCII for "PolyMonitor"

#1

Customer specified input signal

X - none, Z - custom linear signal (specify!) (1)

X - none, B - RS485

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(3)


process controllers Programmable Controller RT28U-R ♦ ♦ ♦ ♦ ♦

Low cost DIN-rail case and 11-pin box for rail mounting 3-digit bright LED display Universal input for 4 RTDs, 6 T/Cs, and 4 linear types RS485 serial interface available

RT28U-R is a modification of RT28U for rail mounting. It is equipped with a 3-digit LED display, a universal input for Pt100, Pt1000, PTC, 6 thermocouple types as well as for linear current, voltage, and resistive signals from external transmitters and can have up to 2 programmable relay control/alarm outputs. The device has a built-in circuit for self-testing and self-calibration, manual measurement offset setting, and automatic software compensation of line resistance and cold junction temperature. The display-to-input correspondence (in case of linear input), decimal point position, temperature measurement unit, and offset value are also programmable. Thanks to its universal input, serial interface, and excellent price-to-performance ratio, RT28U-R is a widely applicable device.

Technical specifications Input Pt100 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire PTC (1k at 25 °C); 3-wire PTC (2k at 25 °C); 3-wire Thermocouple "T" Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" Linear voltage 0...10 V Linear current 0(4)...20 mA Linear resistive 0...1 kΩ Custom linear (option) (1) Two-wire external transmitter Manual input offset Input type selection Decimal point selection Temperature measurement unit

Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Alarms Serial interface (4)

(programmable) -100...850 °C -100...600 °C -50...150 °C -50...150 °C -40...400 °C -20...999 °C -20...999 °C 0...999 °C 0...999 °C 100...999 °C -199...999, programmable -199...999, programmable -199...999, programmable -199...999, programmable 4...20 mA (2) programmable programmable programmable °C or °F, programmable (up to 2 relay outputs) 5A/250V w/ NO/NC or NO (3) contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF within input range limits programmable RS485, isolated

Accuracy 0.3% (5) from span 0.02% from span for 1 °C automatic, -10...80 °C automatic, up to 2 х 25 Ω

Measurement error Temperature drift Cold junction compensation RTD line compensation

Power supply Mains supply voltage Isolated low voltage Non-isolated low voltage External mains transformer (6) Consumption

230 VAC or 115 VAC 12…24 V or 24 VAC 12…24 V 9(12) VAC max. 1.5 VA

Indication and controls 3 LED indicators 2 LEDs for output state 3 membrane keys

Digital display LEDs Keyboard

Operating conditions -10...65 °C 0...85 %RH

Ambient temperature Ambient humidity

Design and materials Dimensions [mm] Mounting Display digit height [mm] Maximum weight [g] Protection, front/terminals Case material Wiring

'R1'

'R2'

70x110x58 on rail 14 300 IP20 plastic screw terminals

35x78x91 in socket or on rail 10 200 IP44 / IP20 plastic socket UNDECAL (6)

(1)

Instead of linear current Provides loop supply voltage - 24 VDC (only w/ isolated power supply). NO/NC for case 'R1'; NO for case 'R2' (4) Not available for case 'R2'. (5) 0.5% for T/Cs "S", "R", and "B" (6) Ordered separately (see 'Accessories') (2)

Ordering code

RT28U - G0.G1.G5G5.G9'9" - #1

Code Feature or option

Code values

G0

Case

R1 - for rail mounting, R2 - 11-pin box

G1

Power supply

A - 230 VAC, B - 115 VAC, E - 9(12) VAC w/ external transformer (6), P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

G5

Relay output

X - none, A - relay NO (3), C - relay NO/NC (3), D - SSR, J - for external SSR, M - isolated MOS gate (4)

G9'

Serial interface

G9"

Protocol

A - ASCII, C - ASCII for "PolyMonitor"

#1

Customer specified input signal

X - none, Z - custom linear signal (specify!) (1)

X - none, B - RS485

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(3)


process controllers Programmable ON/OFF Controller RT38 ♦ ♦ ♦ ♦ ♦ ♦

Low cost 5 DIN cases - up to 1/32 DIN Low power consumption Semi-universal input Various power supplies Fully programmable parameters

The cheap programmable controller RT38 is designed for wide range of ON/OFF control applications. Equipped with a 3-digit LED display, RT38 is especially suitable for measuring and controlling various technological values with resolution of up to 1000 points. It can be ordered in various cases including the smallest 1/32 DIN case, and for different power supplies. The device has 1 programmable relay control/alarm output and is available in 2 universal-input versions: RTD - for 7 selectable Ptx and 4 Cux sensor types, and T/C - for 3 selectable thermocouples as well as versions for linear current and voltage signals. RT38 allows an automatic software compensation of line resistance and cold junction temperature. The display-to-input correspondence (in case of linear input), the decimal point position, the temperature measuring unit as well as the offset value are also programmable. Thanks to its power supply options, semi-universal input, and excellent price-to-performance ratio, RT38 is an exceptionally widely applicable device.

Technical specifications RTD, DIN (w=1.385); 3-wire RTD, GOST (w=1.391); 3-wire RTD measurement range Thermocouple "T" Thermocouple "J" Thermocouple "K" Linear voltage 0...10 V Linear current 0(4)...20 mA Two-wire external transmitter RTD or T/C type selection Decimal point selection Temperature measurement unit

(programmable) Pt50, Pt100, Pt500, Pt1000 Pt46, Pt50, Pt100, Cu50, Cu100 -100...600 °C -40...400 °C -20...999 °C -20...999 °C -199...999, programmable -199...999, programmable 4...20 mA (1) programmable programmable °C or °F, programmable

Output Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Alarms

5A/250V w/ NO/NC (2) contact 1A/250VAC (3) 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF within input range limits programmable

Accuracy Measurement error Temperature drift Cold junction compensation RTD line compensation

0.3% from span 0.02% from span for 1 °C automatic, -10...80 °C automatic, up to 2 х 25 Ω

Power supply

Indication and controls

Operating conditions Operating temperature Operating humidity

Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals) (5)

(2)

(6)

Ordering code

3 LED indicators LED for output state 2 or 3 membrane keys, lockable

Digital display LEDs Keyboard

(1)

Provides loop supply voltage - 24 VDC (only w/ isolated power supply) NO for case 'M' (3) 0.2A/250VAC for case 'M' (4) Not available for case 'M'

230 VAC (4) or 115 VAC (4) 90…250 VAC/DC (5) 12…24 VAC/DC or 24 VAC (4) 12…24 VAC/DC 9(12) VAC max. 1.5 VA

Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage External mains transformer (6) Consumption

'B'

'H' / 'V'

'S'

-10...65 °C 0...85 %RH 'L' 'M'

96x96 96x48 48x48 72x36 48x24 panel panel panel panel panel 90x90 90x42 45x45 71x29 46x22 98 56 98 100 42 14 14 20 10 9 250 150 300 200 30 IP54/20 IP54/20 IP54/20 IP54/20 IP54/20 IP65 IP65 IP65 (7) plastic plastic plastic plastic plastic plug-in plug-in screw screw screw

Not available for cases 'L' and 'M' Ordered separately (see 'Accessories') Ask for availability! (8) Not available for cases 'S' and 'M' (7)

RT38 - G0.G1.G5.G6 - #1

Code Feature or option

Code values

G0

Case (front size)

B - 96x96 mm, H - 96x48 mm, V - 48x96 mm, S - 48x48 mm, L - 72x36 mm, M - 48x24 mm

G1

Power supply

A - 230 VAC (4), B - 115 VAC (4), C - 90…250 V (5), E - 9(12) VAC w/ external transformer (6), P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC (4)

G5

Relay output

X - none, C - relay NO/NC (2), D - SSR, J - for external SSR, M - isolated MOS gate

G6

Input

B - RTD (programmable), C - thermocouple (programmable), D - 0(4)…20 mA, DK - 0…10 V

#1

Increased front protection

X - none, P - IP65 front protection (8)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Input


process controllers Programmable ON/OFF Controller RT38-R ♦ ♦ ♦ ♦ ♦ ♦

Low cost 11-pin box for DIN-rail mounting 3-digit bright LED display Semi-universal input Various power supplies Fully programmable parameters

Technical specifications Input RTD, DIN (w=1.385); 3-wire RTD, GOST (w=1.391); 3-wire RTD measurement range Thermocouple "T" Thermocouple "J" Thermocouple "K" Linear voltage 0...10 V Linear current 0(4)...20 mA Two-wire external transmitter RTD or T/C type selection Decimal point selection Temperature measurement unit

(programmable) Pt50, Pt100, Pt500, Pt1000 Pt46, Pt50, Pt100, Cu50, Cu100 -100...600 °C -40...400 °C -20...999 °C -20...999 °C -199...999, programmable -199...999, programmable 4...20 mA (1) programmable programmable °C or °F, programmable

Output 5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF within input range limits programmable

Accuracy 0.3% from span 0.02% from span for 1 °C

Measurement error Temperature drift (2)

Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage External mains transformer (2) Consumption

230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC 9(12) VAC max. 1.5 VA

Indication and controls Digital display LEDs Keyboard

3 LED indicators, 10 mm LED for output state 3 membrane keys, lockable

Operating conditions

Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Alarms

(1)

Power supply

-10...65 °C 0...85 %RH

Operating temperature Operating humidity

Design and materials Case material Mounting Wiring Dimensions Weight Protection, front/terminals

plastic in socket or on 35 mm DIN rail socket UNDECAL (2) 35x78x91 mm 180 g IP44 / IP20

Provides loop supply voltage - 24 VDC (only w/ isolated power supply) Ordered separately (see 'Accessories')

Ordering code

RT38 - R.G1.G5.G6

Code Feature or option

Code values

Power supply

G5

Relay output

X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate

G6

Input

B - RTD (programmable), C - thermocouple (programmable), D - 0(4)…20 mA, DK - 0…10 V

COMECO reserves the right of changing specifications without prior notice!

G1

A - 230 VAC, B - 115 VAC, C - 90…250 V, E - 9(12) VAC w/ external transformer (2), P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


process controllers Programmable Controller RT18 ♦ ♦ ♦ ♦ ♦

Self-tuning ON/OFF or PI control algorithm 4 DIN cases - up to 1/16 DIN Fixed input Various power supplies Easy programming

RT18 is a programmable temperature ON/OFF controller with fixed input for various temperature sensors and linear signals. It is equipped with 3-digit LED display and relay control output. For easy mounting in existing cutouts, RT18 is available with 48x48, 96x48, 48x96, and 96x96 mm front sizes. To control its output, the device may utilize either ON/OFF or PI auto-tune control algorithm, the latter being a convenient solution that saves installation time and costs and provides precise control. The reliable operation in noisy industrial environment also extends RT18 application area.

Technical specifications Input

(total number of points for any range: 999)

Pt50 (w=1.385); 3-wire Pt100 (w=1.385); 3-wire Pt500 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire Cu100; 3-wire Cu50; 3-wire Other RTD (1) Thermocouple "J" Thermocouple "K" Thermocouple "L" Thermocouple "L-GOST" Other thermocouple (1) Linear voltage 0...10 V Linear current 0(4)...20 mA Custom linear voltage; max. 40 V Custom linear current; max. 80 mA

-9.9(-50)...90.0(500) °C -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(200) °C -9.9(-50)...90.0(200) °C min. -99...max. 500 °C 0...999(600) °C (2) (2) 0...999(850) °C 0...900(600) °C (2) 0...650(550) °C (2) min. -99(0)...max. 900(999) °C (2) -99...900 (0...999) (2,3,4) (2,3,4) -99...900 (0...999) min. -99...max. 999 (2,3,4) min. -99...max. 999 (2,3,4)

Accuracy Measurement error Temperature drift Cold junction compensation RTD line compensation (option)

Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption

Operating conditions Operating temperature Operating humidity

Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Programmable parameters

Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals)

(1)

(4)

(2)

(5)

Provides loop supply voltage - 24 VDC (only w/ isolated power supply) Ask for availability!

Code values

G0

Case (front size)

B - 96x96 mm, H - 96x48 mm, V - 48x96 mm, S - 48x48 mm

G1

Power supply

A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

G3

Resolution

B - 1, C - 0.1 (2)

G5

Relay output

X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate

G6'

Input signal

G6"

(7)

'H' 96x48 panel 90x42 98 14 300 IP54/20 IP65 plastic plug-in

RT18 - G0.G1.G3.G5.G6'6".G8 - #1.#2

Code Feature or option

(6)

'B' 96x96 panel 90x90 98 20 350 IP54/20 (5) IP65 plastic plug-in

-10...65 °C 0...85 %RH 'V' 'S' 48x96 48x48 panel panel 42x90 45x45 98 100 14 10 300 200 IP54/20 IP54/20 IP65 plastic plastic plug-in screw

Sensor

B - thermoresistance, C - thermocouple, D - linear, Z - other on request RTD

B - Pt50, D - Pt100, F - Pt500, G - Pt1000, H - Cu50, K - Cu100, Z - other (1)

T/C

J - "J", K - "K", L - "L" , M - "L-GOST", Z - other (1)

linear

B - 0…20 mA (3), C - 4…20 mA (3), K - 0…10 V (3), Z - other (3) (6)

G8

Control algorithm

A - ON/OFF, C - self-tuning PI

#1

Compensation for 3-wire RTD line

X - none, LC - built-in line resistance compensation

#2

Increased front protection

X - none, P - IP65 front protection (7)

Specify the direction of control action (heating or cooling relay action). Not available for case 'S'!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org

COMECO reserves the right of changing specifications without prior notice!

Ordering code

3 LED indicators LED for output state 3 membrane keys

Digital display LEDs Keyboard

Design and materials

Custom; specify range within the limits stated. For self-tuning PI algorithm, ONLY the alternative ranges are applicable. (3) Specify lower and upper display limits.

230 VAC or 115 VAC 90...250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 3 VA

Indication and controls

Output 5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF, self-tuning PI within input range limits according to control algorithm

0.4% from span 0.005% from span for 1 °C ± 1 °C 0.01% from span for 1 Ω


process controllers Programmable Controller RT28 ♦ ♦ ♦ ♦ ♦ ♦

2 output relays ON/OFF or PD-for-MV control algorithm 3 DIN cases Fixed input Various power supplies Easy programming

The simple-design low-cost microprocessor-based controller RT28 combines the advantages of the microprocessor devices with the high reliability of analog controllers. It is available with 96x48, 48x96, and 96x96 mm DIN-sized front panel and can be equipped with up to 2 control relays. To control its outputs, RT28 may utilize either ON/OFF (heat/cool) duplex or PD control algorithm. The ON/OFF control algorithm allows flexible programming of the action of each relay for solving variety of problems. The PD algorithm results in PI control when used to control motorized valve actuators without position feedback. The reliable operation even in the presence of electromagnetic disturbances and the attractive price also account for the success of the RT28 controller.

Technical specifications (total number of points for any range: 999) -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(200) °C -9.9(-50)...90.0(200) °C min. -99...max. 500 °C 0...999(600) °C 0...999(850) °C 0...900(600) °C 0...650(550) °C min. -99(0)...max. 900(999) °C -99...900 (0...999) (2,3) -99...900 (0...999) (2,3) min. -99...max. 999 (2,3) min. -99...max. 999 (2,3)

Pt50 (w=1.385); 3-wire Pt100 (w=1.385); 3-wire Pt500 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire Cu100; 3-wire Cu50; 3-wire Other RTD (1) Thermocouple "J" Thermocouple "K" Thermocouple "L" Thermocouple "L-GOST" Other thermocouple (1) Linear voltage 0...10 V Linear current 0(4)...20 mA Custom linear voltage; max. 40 V Custom linear current; max. 80 mA

Outputs

(up to 2 relay outputs)

Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Programmable parameters

5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF, PD within input range limits according to control algorithm

Accuracy

Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption

3 LED indicators 2 LED for output state 3 membrane keys

Digital display LEDs Keyboard

Operating conditions Ambient temperature Ambient humidity

Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals) (4)

(2)

(5)

Ordering code

230 VAC or 115 VAC 90...250 V 12…24 V or 24 VAC 12…24 V max. 3 VA

Indication and controls

(1)

Custom; specify range within the limits stated. Specify lower and upper display limits. (3) Provides loop supply voltage - 24 VDC (only w/ isolated power supply)

0.4% from span 0.005% from span for 1 °C ± 1 °C 0.01% from span for 1 Ω

Measurement error Temperature drift Cold junction compensation RTD line compensation (option)

'B' 'H' 96x96 96x48 panel panel 90x42 90x90 98 98 14 20 300 350 IP54 / IP20 IP54 / IP20 IP65 IP65 (4) plastic plastic plug-in plug-in

-10...65 °C 0...85 %RH 'V' 48x96 panel 42x90 98 14 300 IP54 / IP20 IP65 plastic plug-in

Ask for availability! Ordered separately (see 'Accessories')

RT28 - G0.G1.G3.G5G5.G6'6".G8 - #1.#2

Code Feature or option

Code values

G0

Case (front size)

B - 96x96 mm, H - 96x48 mm, V - 48x96 mm

G1

Power supply

A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

G3

Resolution

B - 1, C - 0.1

G5

Relay output

X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate

G6'

Input signal

G6"

Sensor

B - thermoresistance, C - thermocouple, D - linear, Z - other on request RTD

B - Pt50, D - Pt100, F - Pt500, G - Pt1000, H - Cu50, K - Cu100, Z - other (1)

T/C

J - "J", K - "K", L - "L" , M - "L-GOST", Z - other (1)

linear

B - 0…20 mA (2), C - 4…20 mA (2), K - 0…10 V (2), Z - other (2)

G8

Control algorithm

A - ON/OFF, D - PD

#1

Compensation for 3-wire RTD line

X - none, LC - built-in line resistance compensation

#2

Increased front protection

X - none, P - IP65 front protection

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org

COMECO reserves the right of changing specifications without prior notice!

Input


process controllers Programmable Controller RT284U ♦ ♦ ♦ ♦ ♦ ♦

Low cost 4-digit bright LED display 5 DIN cases Universal input for 4 RTDs, 6 T/Cs, and 4 linear types Keyboard or encoder adjustment controls RS485 serial interface available

RT284U is designed for wide range of applications. It is equipped with a 4-digit LED display, a universal input for Pt100, Pt1000, PTC, 6 thermocouple types as well as for linear current, voltage, and resistive signals from external transmitters and can have up to 2 programmable relay control/alarm outputs. RT284U can be ordered with either keyboard or unique rotating encoder for set-point adjustment and programming. All modifications have a built-in circuit for self-testing and self-calibration, manual measurement offset setting, and automatic software compensation of line resistance and cold junction temperature. The display-to-input correspondence (in case of linear input), decimal point position, temperature measurement unit, and offset value are also programmable. Thanks to its universal input, the available various enclosures and serial interface as well as excellent price-to-performance ratio, RT284U is an exceptionally widely applicable device.

Technical specifications Accuracy

(programmable)

Pt100 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire PTC (1k at 25 °C); 3-wire PTC (2k at 25 °C); 3-wire Thermocouple "T" Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" Linear voltage 0...10 V Linear current 0(4)...20 mA Linear resistive 0...1 kΩ Custom linear (option) (1) Two-wire external transmitter Manual input offset Input type selection Decimal point selection Temperature measurement unit

Outputs

Power supply Mains supply voltage (6) SMPS voltage Isolated low voltage Non-isolated low voltage External mains transformer (7) Consumption

Operating conditions Ambient temperature Ambient humidity

Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals)

(1)

(6)

(2)

(7)

Ordering code

4 LED indicators 2 LEDs for output state keyboard w/ 3 keys or rotary encoder (8)

Digital display LEDs Controls

5A/250V w/ NO/NC or NO (3) contact 1A/250VAC (4) 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF within input range limits programmable RS485, isolated

Instead of linear current Provides loop supply voltage - 24 VDC (only w/ isolated power supply). (3) For case 'Q' and case 'S' w/ SMPS, 1st relay is NO; for case 'L', case 'Q' w/ SMPS, and case 'S' w/ serial interface, 2nd relay is NO. (4) 0.2A/250VAC for case 'L' (5) 0.5% for T/Cs "S", "R", and "B"

230 VAC or 115 VAC 90…250 V 12…24 V or 24 VAC 12…24 V 9(12) VAC max. 2 VA

Indication and controls

(up to 2 relay outputs)

Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Alarms Serial interface

0.3% (5) from span 0.02% from span for 1 °C automatic, -10...80 °C automatic, up to 2 х 25 Ω

Measurement error Temperature drift Cold junction compensation RTD line compensation

-100...850 °C -100...600 °C -50...150 °C -50...150 °C -40...400 °C -20...1000 °C -20...1300 °C 0...1700 °C 0...1700 °C 100...1800 °C -1999...9999, programmable -1999...9999, programmable -1999...9999, programmable -1999...9999, programmable 4...20 mA (2) programmable programmable programmable °C or °F, programmable

'B' 'H' / 'V' 'Q' 96x96 96x48 72x72 panel panel panel 90x90 90x42 67x67 98 98 66 14 20 14 300 350 300 IP54/20 IP54/20 IP54/20 IP65 IP65 (9) plastic plastic plastic plug-in plug-in screw

-10...65 °C 0...85 %RH 'S' 'L' 48x48 72x36 panel panel 45x45 71x29 100 56 10 9 200 150 IP54/20 IP54/20 IP65 plastic plastic screw screw

Not available for case 'L'. Ordered separately (see 'Accessories') Available ONLY for cases 'H', 'V', and 'B'. (9) Ask for availability! (10) Not available for cases 'Q' and 'S'. (8)

RT284U - G0.G1.G4.G5G5.G9'9" - #1.#2

Code Feature or option

Code values

G0

Case (front size)

B - 96x96 mm, H - 96x48 mm, V - 48x96 mm, Q - 72x72 mm, S - 48x48 mm, L - 72x36 mm

G1

Power supply

A - 230 VAC (6), B - 115 VAC (6), C - 90…250 V, E - 9(12) VAC w/ external transformer (7), P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

G4

Adjustment controls

A - keyboard, H - rotary encoder (8)

G5

Relay output

X - none, A - relay NO (3), C - relay NO/NC (3), D - SSR, J - for external SSR, M - isolated MOS gate

G9'

Serial interface

X - none, B - RS485

G9"

Protocol

A - ASCII, C - ASCII for "PolyMonitor"

#1

Increased front protection

X - none, P - IP65 front protection (10)

#2

Customer specified input signal

X - none, Z - custom linear signal (specify!) (1)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org

COMECO reserves the right of changing specifications without prior notice!

Input


process controllers Programmable Controller RT384 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

5 DIN cases Universal programmable input Various control algorithms including auto-tuning PID-pulse and PID for motor valves Programmable digital filter Manual mode for bumpless switching Calibration and self-calibration RS485 serial interface available

RT384 is a multifunctional programmable controller with universal input for the most common thermoresistances, thermocouples, and linear signals. The input has a built-in automatic software compensation of line resistance and cold junction temperature as well as automatic software compensation of temperature drift, and can be calibrated manually. RT384 is also equipped with a programmable input filter and a 4-digit display with programmable refresh rate. Available are various options for access restriction. The device can have up to 2 outputs (2 relays or 1 relay and 1 analog output), which can control variety of actuators through different programmable control algorithms. RT384 can work in manual or automatic mode, and an RS485 serial interface enables networking.

Technical specifications (programmable)

Pt100 (w=1.385, 1.391); 3-wire Cu100 (w=1.426, 1.428); 3-wire Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" Thermocouple "C" Thermocouple "L - GOST" Linear voltage 0...50 mV (1) Linear current 0...20 mA Linear current 4...20 mA Input type selection Decimal point selection Digital filter Input calibration

Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Operation modes Control algorithms Auto-tuning Alarms Other control features Analog output (5) Serial interface

-100...600 °C -50...200 °C 0...1000 °C 0...1300 °C 0...1700 °C 0...1700 °C 100...1800 °C 0...2300 °C 0...600 °C -1999...9999, programmable -1999...9999, programmable -1999...9999, programmable (2) programmable programmable programmable programmable (up to 2 outputs) 5A/250V w/ NO/NC or NO (3) contact 1A/250VAC (4) 0.1A/60V, optically isolated 5…24 V, 30 mA manual and automatic ON/OFF, PID-pulse, and PID for motor valves, programmable programmable programmable BUMPLESS and ANTI-WINDUP 4(0)...20 mA or 0...10 V, isolated RS485, isolated

(1)

Other voltage ranges can be obtained by the means of 2 external resistors. Provides loop supply voltage - 24 VDC (only w/ isolated power supply). (3) For case 'Q' and case 'S' w/ serial interface, 1st relay is NO; for cases 'Q' and 'S' w/ SMPS, 2nd relay is NO. (4) 0.2A/250VAC for case 'L' (2)

Ordering code

Accuracy 0.3% (6) from span 0.01% from span for 1 °C automatic software automatic software automatic software

Measurement error Temperature drift Self-calibration Cold junction compensation RTD line compensation

Power supply Mains supply voltage (7) SMPS voltage (7) Isolated low voltage Non-isolated low voltage Consumption

230 VAC or 115 VAC 90…250 V 12…24 V or 24 VAC (7) 12…24 V max. 3 VA

Indication and controls 4 LED indicators 2 LEDs for output state 3 membrane keys

Digital display LEDs Keyboard

Operating conditions Ambient temperature Ambient humidity

Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals)

'B' 'H' / 'V' 'Q' 96x96 96x48 72x72 panel panel panel 90x90 90x42 67x67 98 98 66 20 14 / 10 14 300 350 300 IP54/20 IP54/20 IP54/20 IP65 IP65 (8) plastic plastic plastic plug-in plug-in screw

-10...55 °C 0...85 %RH 'S' 'L' 48x48 72x36 panel panel 45x45 71x29 100 56 10 9 200 150 IP54/20 IP54/20 IP65 plastic plastic screw screw

(5)

Instead of 1st relay! If mounted, it can be programmed as control or retransmission! 0.5% for noble thermocouples (7) Not available for case 'L'. (8) Ask for availability! (9) Not available for cases 'Q' and 'S'. (6)

RT384 - G0.G1.G5G5.G9'9".G11 - #1

Code Feature or option

Code values

G0

Case (front size)

B - 96x96 mm, H - 96x48 mm, V - 48x96 mm, Q - 72x72 mm, S - 48x48 mm, L - 72x36 mm

G1

Power supply

A - 230 VAC (7), B - 115 VAC (7), C - 90…250 V (7), P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC (7)

G5

Relay output

X - none, A - relay NO (3), C - relay NO/NC (3), D - SSR, J - for external SSR, M - isolated MOS gate

G9'

Serial interface

X - none, B - RS485

G9"

Protocol

A - ASCII, C - ASCII for "PolyMonitor"

G11

Analog output (5,8)

X - none, E - 0…20 mA, F - 4…20 mA, K - 0…10 V

#1

Increased front protection

X - none, P - IP65 front protection (9)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org

COMECO reserves the right of changing specifications without prior notice!

Input


process controllers Programmable Controller RT484 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

Two 4-digit displays 4 DIN cases Universal programmable input Various control algorithms including auto-tuning PID-pulse and PID for motor valves Programmable digital filter Manual mode for bumpless switching Calibration and self-calibration RS485 serial interface available

RT484 is a multifunctional programmable controller with a universal input for the most common thermoresistances, thermocouples, and linear signals. The input has a built-in automatic software compensation of line resistance and cold junction temperature as well as automatic software compensation of temperature drift, and can be calibrated manually. RT484 is also equipped with a programmable input filter and two 4-digit displays with programmable refresh rate. Available are various options for access restriction. The device can have up to 2 outputs (2 relays or 1 relay and 1 analog output), which can control variety of actuators through different programmable control algorithms. RT484 can work in manual or automatic mode, and an RS485 serial interface enables networking.

Technical specifications (programmable)

Pt100 (w=1.385, 1.391); 3-wire Cu100 (w=1.426, 1.428); 3-wire Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" Thermocouple "C" Thermocouple "L - GOST" Linear voltage 0...50 mV (1) Linear current 0...20 mA Linear current 4...20 mA Input type selection Decimal point selection Digital filter Input calibration

Outputs

-100...600 °C -50...200 °C 0...1000 °C 0...1300 °C 0...1700 °C 0...1700 °C 100...1800 °C 0...2300 °C 0...600 °C -1999...9999, programmable -1999...9999, programmable -1999...9999, programmable (2) programmable programmable programmable programmable (up to 2 outputs)

Relay electromechanical Solid state relay MOS gate Output for external SSR Operation modes Control algorithms Auto-tuning Alarms Other control features Analog output (3) Serial interface

5A/250V w/ NO/NC or NO contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA manual and automatic ON/OFF, PID-pulse, and PID for motor valves, programmable programmable programmable BUMPLESS and ANTI-WINDUP 4(0)...20 mA or 0...10 V, isolated RS485, isolated

Accuracy

Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption

2 x 4 LED indicators 2 LEDs for output state 3 membrane keys

Digital display LEDs Keyboard

Operating conditions Operating temperature Operating humidity

Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] PV display digit height [mm] SV display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals) (4)

(2)

(5)

Ordering code

230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 5 VA

Indication and controls

(1)

Other voltage ranges can be obtained by the means of two external resistors. Provides loop supply voltage - 24 VDC (only w/ isolated power supply) (3) Instead of 1st relay! If mounted, it can be programmed as control or retransmission!

0.3% (3) from span 0.01% from span for 1 °C automatic software automatic software automatic software

Measurement error Temperature drift Self-calibration Cold junction compensation RTD line compensation

(6)

'B' 'H' / 'V' 96x96 96x48 panel panel 90x42 90x90 98 98 20 14 / 10 10 14 300 350 IP54/20 IP54/20 IP65 IP65 (5) plastic plastic plug-in plug-in

-10...55 °C 0...85 %RH 'Q' 'S' 72x72 48x48 panel panel 45x45 67x67 100 66 10 14 10 10 200 300 IP54/20 IP54/20 plastic plastic screw screw

0.5% for noble thermocouples Ask for availability! Not available for cases 'Q' and 'S'

RT484 - G0.G1.G5G5.G9'9".G11 - #1

Code Feature or option

Code values

G0

Case (front size)

B - 96x96 mm, H - 96x48 mm, V - 48x96 mm, Q - 72x72 mm, S - 48x48 mm

G1

Power supply

A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

G5

Relay output

X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate

G9'

Serial interface

X - none, B - RS485

G9"

Protocol

A - ASCII, C - ASCII for "PolyMonitor"

G11

Analog output (3,5)

X - none, E - 0…20 mA, F - 4…20 mA, K - 0…10 V

#1

Increased front protection

X - none, P - IP65 front protection (6)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org

COMECO reserves the right of changing specifications without prior notice!

Input


process controllers Universal Programmable Controller RT1800 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

5 DIN sizes Two 4-digit displays plus bargraph Universal programmable input Optional remote set-point input PID-fuzzy auto-tuning with bumpless Auto/Manual Up to 4 relays and analog control output Retransmission analog output available Triple isolation RAMP/SOAK function 2-program-with-up-to-8-point pattern set point available Serial interface available

RT1800 is a microprocessor-based controller with universal input, analog output, and up to 4 relays (control or alarm) that may be controlled through a number of algorithms such as ON/OFF, ON/OFF heating/cooling duplex, motor-valve control, PID, and self-tuning PID. A bumpless auto-manual change-over is built in the PID algorithm. A start-on timer allows one of output relays to be time-controlled. Two displays (for the measured value and for the set point) as well as an output-control bargraph ease operator duties. Carefully protected from electromagnetic disturbances by featuring both input and output optical isolation, RT1800 is well equipped for troublefree operation in harsh industrial conditions.

Technical specifications Pt100 (w=1.385, 1.391); 3-wire Thermocouple "B" Thermocouple "E" Thermocouple "J" Thermocouple "K" Thermocouple "L" Thermocouple "N" Thermocouple "R" Thermocouple "S" Thermocouple "T" Thermocouple "U" Thermocouple "D" Linear voltage -10...50 mV Linear current 0(4)...20 mA Input type/range selection Input isolation Auxiliary input (2) (option) Signal type Function

Control outputs Relay electromechanical (5) Solid state relay MOS gate Output for external SSR Analog output (6) Isolation Control algorithms Auto-tuning Auto/Manual control Pattern set point

Alarm outputs Relay electromechanical Solid state relay (5) MOS gate Output for external SSR

(programmable) (1) -199.9...600.0 °C [6] 0...1820 °C [1] 0...1000 °C [2] 0...400.0(1200) °C [6] 0...400.0(1200) °C [6] 0...800 °C [2] 0...1300 °C [2] 0...1769 °C [2] 0...1769 °C [2] -199.9...400.0 °C [3] -199.9...600.0 °C [3] 0...2320 °C [2] -1999...9999, programmable [4] -1999...9999, programmable [2] programmable optical, 1500 VAC

RS232 or RS485 configuration and networking up to 31 1500 VAC MODEBUS ASCII or RTU

Interface type Function Network devices Isolation Protocol

Accuracy 0.3% from span 0.01% from span for 1 °C 250 ms automatic software automatic software

Measurement error Temperature drift Sample time Cold junction compensation RTD line compensation

Power supply Supply voltage Consumption

85…265 VAC max. 4 VA

Indication and controls 0(4)...20 mA remote set point (3) (up to 2 outputs ) (4) 3A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 24 V, 20 mA 0(4)...20 mA (≤ 600 Ω), 0...10 V (≥ 1 MΩ) optical, 1500 VAC ON/OFF and PID-fuzzy, programmable programmable bumpless, keyboard switched (7) 1(2) programs w/ 16(8) points (up to 2 outputs (3)) (4) 3A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 24 V, 20 mA

Retransmission output (8) (option) Signal type Function Isolation

Serial interface (9)

0(4)...20 mA (≤ 600 Ω), 0...10 V (≥ 1 MΩ) PV or SV transmission optical, 1500 VAC

Digital display (7) Bargraph display LEDs Keyboard

2 x 4 LED indicators st 10-point LED for 1 control output, 0...100% 8 (6 for 'S') control LEDs 5 (4 for 'S') membrane keys

Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity

Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] PV display digit height [mm] SV display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals)

'B' 96x96 panel 91x91 81 14 10 300 IP56/20 IP65 plastic screw

0...50 °C 20...85 %RH -20...65 °C 0...95 %RH, non-condensing 'H' / 'V' 'Q' 'S' 96x48 panel 91x45 81 8 8 225 IP56/20 IP65 plastic screw

72x72 panel 69x69 81 14 10 225 IP56/20 IP65 plastic screw

48x48 panel 45x45 81 8 8 150 IP56/20 plastic screw

(1)

[n] shows the number of sub-ranges that can be selected via the keyboard. nd For cases 'B', 'H', 'V' – instead of interface; for case 'Q' – instead of 2 alarm output; for case 'S' – instead of interface and retransmission analog output For cases 'B', 'H', 'V' – 2 control + 2 alarm or 1 control + 3 alarm; for case 'Q' – 1 control + 2 alarm or 2 control + 1 alarm; for case 'S' – 2 control + 2 alarm (4) For cases 'B', 'H', 'V' 2nd control (3rd alarm) relay is NO; for case 'Q' 2nd control (1st alarm) relay is NO; for case 'S' all relays are NO. (5) Ask for availability! (6) Instead of control relay! (7) Not available for case 'S'! (8) nd st For cases 'H', 'V' – instead of 2 alarm output; for case 'S' – instead of interface or 1 alarm output. (9) st For cases 'B', 'H', 'V' – instead of auxiliary input; for case 'S' – instead of retransmission or 1 alarm output. (2)

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org

COMECO reserves the right of changing specifications without prior notice!

Main input


process controllers

Ordering code

RT1800 - G0.G5'G5'.G5"G5"G5".G8.G9'9".G11 - #1.#2.#3

Code Feature or option G0

Case (front size)

G5'

Relay control output

G5"

Relay alarm output

G8

Control algorithm

G9'

Serial interface

G9"

Protocol

G11

Analog control output

#1

Auxiliary input

#2

Analog retransmission output

#3

Increased front protection

Code values B - 96x96 mm, H - 96x48 mm, V - 48x96 mm, Q - 72x72 mm, S - 48x48 mm

(3)

(3)

X - none, C - relay NO/NC

(4)

, D - SSR

(5)

, J - for external SSR, M - isolated MOS gate

X - none, C - relay NO/NC

(4)

, D - SSR

(5)

, J - for external SSR, M - isolated MOS gate

F - PID-fuzzy (ON/OFF), H - PID-fuzzy plus pattern control

(9)

X - none, A - RS232, B - RS485 M - MODEBUS (ASCII), N - MODEBUS (RTU) (6)

X - none, E - 0…20 mA, F - 4…20 mA, K - 0…10 V

(2)

X - none, E - 0…20 mA, F - 4…20 mA X - none, E - 0…20 mA, F - 4…20 mA, K - 0…10 V X - none, P - IP65 front protection

(7)

COMECO reserves the right of changing specifications without prior notice!

(8)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org


process controllers Universal Programmable Controller RT1900-R ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

DIN-rail or wall mounting 4-digit display Triple isolation Universal programmable input PID-fuzzy auto-tuning Up to 3 relay and 1 analog outputs RAMP/SOAK pattern control RS485 MODEBUS serial interface USB port for parameter storage

RT1900-R is a DIN-rail mounting microprocessor-based controller with universal input accepting Pt100, 10 thermocouple types and various linear signals. It can have up to 3 relays (control or alarm) and analog output that may be controlled through ON/OFF and self-tuning PID-fuzzy algorithms as well as optional RAMP/SOAK pattern control. A bumpless auto-manual change-over is also built in the PID algorithm. RT1900-R is equipped with 4-digit LED display and 4-button keyboard for programming. A triple input/output/supply isolation protects the controller from electromagnetic disturbances. Communication features include RS485 MODEBUS interface and USB port for program parameter storage. RT1900-R is well equipped for trouble-free operation in harsh industrial conditions.

Technical specifications Pt100 (w=1.385, 1.391); 3-wire Thermocouple "B" Thermocouple "E" Thermocouple "J" Thermocouple "K" Thermocouple "L" Thermocouple "N" Thermocouple "R"("S") Thermocouple "T" Thermocouple "U" Linear DC (mV) Linear DC (V) Linear DC (mA) Linear resistive Linear display Input type/range selection Input isolation

Outputs

(up to 3 outputs) Maximum 2 outputs (2) 5A/250V w/ NO contact 1A/250VAC 0.1A/60V, optically isolated 24 V, 20 mA 0(4)...20 mA (≤ 560 Ω), 0...5(10) V (≤ 20mA) optical, 1500 VAC ON/OFF and PID-fuzzy, programmable programmable 1(2) programs w/ 16(8) points Maximum 3 outputs (2) 5A/250V w/ NO contact

Control outputs - relay electromechanical (3) - solid state relay - MOS gate - output for external SSR (3) - analog output (load) - isolation - control algorithms - auto-tuning - RAMP/SOAK pattern Alarm outputs - relay electromechanical (1) (2)

Communication Serial interface (3) - function - network USB interface - function

isolated RS485, MODEBUS configuration and networking max. 32 devices, max. 1200 m mini-A USB side connector parameter storage

Accuracy Measurement error Temperature drift Sample time Cold junction compensation RTD line compensation

0.3% from span 0.01% from span for 1 °C 250 ms automatic software automatic software

Power supply Supply voltage Consumption

85…265 VAC max. 4 VA

Indication and controls Digital display Status LEDs Keyboard

4 LED indicators, 7 mm 3 LEDs for output and 1 for program 4 tactile keys

Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity

0...50 °C 20...85 %RH -25...65 °C 0...95 %RH, non-condensing

Design and materials Case material DIN-rail mounting Wall mounting Wiring Dimensions Weight Protection level

plastic on 35 mm DIN rail 4 screws screw terminals 40x107x43 mm approx. 115 g IP10

Some linear ranges may require hardware adjustments (contact COMECO) Maximum total outputs: 2 control + 1 alarm, or 1 control + 2 alarm, or 3 alarm

Ordering code

RT1900 - R.G5'G5'.G5"G5"G5".G8.G9.G11

Code Feature or option G5'

Relay control output

G5"

Relay alarm output

G8

Control algorithm

G9

Serial interface (3)

G11 (3)

(programmable) -199.9...600.0 °C, 6 ranges 0...1820 °C, 1 range 0...900 °C, 2 ranges 0...1200 °C, 6 ranges 0...1200 °C, 6 ranges 0...800 °C, 2 ranges 0...1300 °C, 2 ranges 0...1769 °C, 2 ranges -199.9...400.0 °C, 3 ranges -199.9...600.0 °C, 3 ranges min. -10 mV to max. 50 mV, 4 ranges min. -2 V to max.10 V, 9 ranges 0...20 mA, 4...20 mA 0...5 kΩ -1999...9999, programmable DP programmable (1) optical, 1500 VAC

(2)

(2)

Analog control output

Code values X - none, C - relay NO, D - SSR

(3)

, J - for external SSR, M - isolated MOS gate

X - none, C - relay NO F - PID-fuzzy (ON/OFF), H - PID-fuzzy plus pattern control X - none, B - RS485 (MODEBUS) (3)

X - none, E - 0…20 mA, F - 4…20 mA, I - 0…5 V, K - 0…10 V

Ask for availability!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org

COMECO reserves the right of changing specifications without prior notice!

Input


process controllers Double Programmable Controller RT218 ♦ ♦ ♦ ♦ ♦

Two RT18 controllers in one housing Self-tuning ON/OFF or PI control algorithm Fixed input Various power supplies Easy programming

RT218 combines two RT18 controllers in one 96x96 mm case. Thanks to its lower cost than the combined cost of 2 separate RT18 controllers, this model is often preferred when 2 technological parameters are controlled in one machine or installation or of separate adjacent processes. Typical applications include control of 2 temperatures, temperature and humidity, pressure and temperature, pH and temperature, and other combinations. Each of the 2 incorporated controllers controls its relay output through an ON/OFF or selftuning PI algorithm, the latter being a convenient solution that saves installation time and costs and provides precise control eliminating temperature cycling and excessive start-up overshoot. The reliable operation even in the presence of electromagnetic disturbances and the attractive price also account for the success of the RT218 controller.

Technical specifications Input

(for each controller) -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(200) °C -9.9(-50)...90.0(200) °C min. -99...max. 500 °C 0...999(600) °C (2) 0...999(850) °C (2) 0...900(600) °C (2) 0...650(550) °C (2) min. -99(0)...max. 900(999) °C (2) -99...900 (0...999) (2,3,4) -99...900 (0...999) (2,3,4) min. -99...max. 999 (2,3,4) min. -99...max. 999 (2,3,4)

Pt50 (w=1.385); 3-wire Pt100 (w=1.385); 3-wire Pt500 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire Cu100; 3-wire Cu50; 3-wire Other RTD (1) Thermocouple "J" Thermocouple "K" Thermocouple "L" Thermocouple "L-GOST" Other thermocouple (1) Linear voltage 0...10 V Linear current 0(4)...20 mA Custom linear voltage; max. 40 V Custom linear current; max. 80 mA

Output

(for each controller)

Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Programmable parameters

5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF, self-tuning PI within input range limits according to control algorithm

Accuracy Measurement error Temperature drift Cold junction compensation RTD line compensation (option)

Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption

Indication and controls Digital display LEDs Keyboard

(for each controller) 0.4% from span 0.005% from span for 1 °C ± 1 °C 0.01% from span for 1 Ω (for each controller) 230 VAC or 115 VAC 90...250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 3 VA (for each controller) 3 LED indicators, 14 mm LED for output state 3 membrane keys

Operating conditions -10...65 °C 0...85 %RH

Operating temperature Operating humidity

Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals Increased front IP (option) (5)

plastic in 90x90 mm panel cut-out plug-in terminals 96x96(front)x107 mm 98 mm max. 600 g IP54 / IP20 IP65

(1)

Custom; specify range within the limits stated. For self-tuning PI algorithm, ONLY the alternative ranges are applicable. Specify lower and upper display limits. (4) Provides loop supply voltage - 24 VDC (only w/ isolated power supply) (5) Ask for availability! (2)

Ordering code

RT218 - G1(G1).G3(G3).G5(G5).G6'6"(G6'6").G8(G8) - #1(#1).#2 (6)

Code Feature or option Power supply

A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

G3

Resolution

B - 1, C - 0.1 (2)

G5

Relay output

X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate

G6'

Input signal

G6"

(6) (7)

Code values

G1

Sensor

B - thermoresistance, C - thermocouple, D - linear, Z - other on request RTD

B - Pt50, D - Pt100, F - Pt500, G - Pt1000, H - Cu50, K - Cu100, Z - other (1)

T/C

J - "J", K - "K", L - "L" , M - "L-GOST", Z - other (1)

linear

B - 0…20 mA (3), C - 4…20 mA (3), K - 0…10 V (3), Z - other (3)

G8

Control algorithm

A - ON/OFF, C - self-tuning PI (7)

#1

Compensation for 3-wire RTD line

X - none, LC - built-in line resistance compensation

#2

Increased front protection

X - none, P - IP65 front protection (5)

Second controller values are in brackets. Specify the direction of control action (heating or cooling relay action).

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org

COMECO reserves the right of changing specifications without prior notice!

(3)


process controllers Double Programmable Controller RT228 ♦ ♦ ♦ ♦ ♦

Two RT28 controllers in one housing ON/OFF or PD-for-MV control algorithm Fixed input Various power supplies Easy programming

RT228 combines two RT28 controllers in one 96x96 mm case. Thanks to its lower cost than the combined cost of 2 separate RT28 controllers, this model is often preferred when 2 technological parameters are controlled in one machine or installation or of separate adjacent processes. Typical applications include control of 2 temperatures, temperature and humidity, pressure and temperature, pH and temperature, and other combinations. Each of the 2 incorporated controllers controls its relay outputs through an ON/OFF or PD algorithm, and thanks to these relay duplex outputs (2 relays per controller, 4 relays per whole device), RT228 is best suited for controlling motorized valve actuators or other actuators with 2-way action. The reliable operation even in the presence of electromagnetic disturbances makes the RT228 controller a widely applicable device.

Technical specifications Input

(for each controller) -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(500) °C -9.9(-50)...90.0(200) °C -9.9(-50)...90.0(200) °C min. -99...max. 500 °C 0...999(600) °C 0...999(850) °C 0...900(600) °C 0...650(550) °C -99(0)...900(999) °C -99...900 (0...999) (2,3) -99...900 (0...999) (2,3) -99...max. 999 (2,3) -99...max. 999 (2,3)

Pt50 (w=1.385); 3-wire Pt100 (w=1.385); 3-wire Pt500 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire Cu100; 3-wire Cu50; 3-wire Other RTD (1) Thermocouple "J" Thermocouple "K" Thermocouple "L" Thermocouple "L-GOST" Other thermocouple (1) Linear voltage 0...10 V Linear current 0(4)...20 mA Custom linear voltage; max. 40 V Custom linear current; max. 80 mA

Outputs

(for each controller, up to 2 relay outputs)

Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Programmable parameters

5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF, PD within input range limits according to control algorithm

Accuracy Measurement error Temperature drift Cold junction compensation RTD line compensation (option)

Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption

Indication and controls Digital display LEDs Keyboard

(for each controller) 0.4% from span 0.005% from span for 1 °C ± 1 °C 0.01% from span for 1 Ω (for each controller) 230 VAC or 115 VAC 90...250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 3 VA (for each controller) 3 LED indicators, 14 mm 2 LEDs for output state 3 membrane keys

Operating conditions -10...65 °C 0...85 %RH

Operating temperature Operating humidity

Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals Increased front IP (option) (4)

plastic in 90x90 mm panel cut-out plug-in terminals 96x96(front)x107 mm 98 mm max. 600 g IP54 / IP20 IP65

(1)

Custom; specify range within the limits stated. Specify lower and upper display limits. Provides loop supply voltage - 24 VDC (only w/ isolated power supply) (4) Ask for availability! (2)

Ordering code

RT228 - G1(G1).G3(G3).G5G5(G5G5).G6'6"(G6'6").G8(G8) - #1(#1).#2 (5)

Code Feature or option Power supply

A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

G3

Resolution

B - 1, C - 0.1

G5

Relay output

X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate

G6'

Input signal

G6"

(5)

Code values

G1

Sensor

B - thermoresistance, C - thermocouple, D - linear, Z - other on request RTD

B - Pt50, D - Pt100, F - Pt500, G - Pt1000, H - Cu50, K - Cu100, Z - other (1)

T/C

J - "J", K - "K", L - "L" , M - "L-GOST", Z - other (1)

linear

B - 0…20 mA (2), C - 4…20 mA (2), K - 0…10 V (2), Z - other (2)

G8

Control algorithm

A - ON/OFF, C - PD

#1

Compensation for 3-wire RTD line

X - none, LC - built-in line resistance compensation

#2

Increased front protection

X - none, P - IP65 front protection (4)

Second controller values are in brackets.

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org

COMECO reserves the right of changing specifications without prior notice!

(3)


process controllers Double Programmable Controller RT228U ♦ ♦ ♦

Two RT28U controllers in one case Universal input for 4 RTDs, 6 T/Cs, and 3 linear types RS485 serial interface available

RT228U combines two RT28U controllers in one 96x96 mm case. Thanks to its lower cost than the combined cost of 2 separate RT28U controllers, this model is often preferred when 2 technological parameters are controlled in one machine or installation or of separate adjacent processes. Typical applications are control of 2 temperatures, temperature and humidity, pressure and temperature, pH and temperature, and other combinations. Each of the 2 incorporated controllers is equipped with universal input and controls its relay outputs by an ON/OFF algorithm. Thanks to its programmable inputs and displays as well as relay duplex outputs (2 relays per controller, 4 relays per whole device), RT228U is a widely applicable device.

Technical specifications Input Pt100 (w=1.385); 3-wire Pt1000 (w=1.385); 3-wire PTC (1k at 25 °C); 3-wire PTC (2k at 25 °C); 3-wire Thermocouple "T" Thermocouple "J" Thermocouple "K" Thermocouple "S" Thermocouple "R" Thermocouple "B" Linear voltage 0...10 V Linear current 0(4)...20 mA Custom linear (option) (1) Two-wire external transmitter Manual input offset Input type selection Decimal point selection Temperature measurement unit

Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point Alarms Serial interface (2) (3)

Measurement error Temperature drift Cold junction compensation RTD line compensation

Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption

Indication and controls Digital display LEDs Keyboard

(for each controller) 0.3% from span 0.02% from span for 1 °C automatic, -10...80 °C automatic, up to 2 х 25 Ω (for each controller) 230 VAC or 115 VAC 90…250 V 12…24 V or 24 VAC 12…24 V max. 1.5 VA (for each controller) 3 LED indicators, 14 mm 2 LEDs for output state 3 membrane keys

Operating conditions -10...65 °C 0...85 %RH

Ambient temperature Ambient humidity

Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals Increased front IP (option) (3)

plastic in 90x90 mm panel cut-out plug-in terminals 96x96(front)x107 mm 98 mm max. 600 g IP54 / IP20 IP65

Instead of linear current Provides loop supply voltage - 24 VDC (only w/ isolated power supply) Ask for availability!

Ordering code

RT228U - G1(G1).G5G5(G5G5).G9'9"(G9'9") - #1.#2(#2) (4)

Code Feature or option

(4)

Accuracy

Code values

G1

Power supply

A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

G5

Relay output

X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate

G9'

Serial interface

X - none, B - RS485

G9"

Protocol

A - ASCII, C - ASCII for "PolyMonitor"

#1

Increased front protection

X - none, P - IP65 front protection (3)

#2

Customer specified input signal

X - none, Z - custom linear signal (specify!) (1)

Second controller values are in brackets.

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(1)

(for each controller, programmable) -100...850 °C -100...600 °C -50...150 °C -50...150 °C -40...400 °C -20...999 °C -20...999 °C 0...999 °C 0...999 °C 100...999 °C -199...999, programmable -199...999, programmable -199...999, programmable 4...20 mA (2) programmable programmable programmable °C or °F, programmable (for each controller, up to 2 relay outputs) 5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF within input range limits programmable RS485, isolated


process controllers 2-channel Programmable Controller RT180 ♦ ♦ ♦ ♦ ♦ ♦

2 independent control channels in one device 2 DIN cases – horizontal and vertical Universal input for 4 RTDs, 4 T/Cs, and 3 linear types ON/OFF- pulse-mode control RH, pH, and ∆t variants available RS485 serial interface available

RT180 offers an exceptionally convenient and inexpensive solution for 2 loopcontrol applications within 1 machine or 2 adjacent ones. The universal programmable inputs make sensor change easy and convenient, and allow on-site configuring of variety of inputs and controlled physical values. The controller may be used for measurement and control of temperature difference (variant 'D'), pH and temperature (variant 'P'), relative humidity through the "wet-and-dry-bulb thermometer" method (variant 'R'), and in other cases in which 1 device measures and controls 2 physical values. All of this make RT180 widely applicable for both industry and laboratory use.

Technical specifications Inputs

(1 per channel, programmable)

Pt100 (w=1.385); 3-wire Pt50 (w=1.385); 3-wire Cu100; 3-wire Cu50; 3-wire Other RTD (1) Thermocouple "J" Thermocouple "K" Thermocouple "L" Thermocouple "L- GOST" Other thermocouple (1) Linear voltage 0...50 mV Linear current 0(4)...20 mA Custom linear 0...50 mV/mA (option) (1) Input type selection (3) pH +2000...-2000 mV Manual input offset

Outputs

-19.9(99)...99.9(500) °C -99...500 °C -9.9(50)...99.9(200) °C -99...200 °C min. -99...max. 500 °C min. 0...max. 900 °C min. 0...max. 999 °C min. 0...max. 600 °C min. 0...max. 600 °C min. 0...max. 999 °C -99...999, programmable (2) (2) -99...999, programmable -99...999, programmable (2) programmable 0...14 pH through keyboard (1 per channel)

Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Set point

5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF, pulse mode programmable

Serial interface (4) Interface type Protocol

RS485, isolated free ASCII or ASCII for "PolyMonitor"

Accuracy Measurement error Temperature drift Calibration Manual calibration Cold junction compensation RTD line compensation

0.3% from span 0.01% from span for 1 °C automatic software through keyboard automatic software automatic software

Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption

230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 3 VA

Indication and controls Digital display LEDs Keyboard

2 x 3 LED indicators 2 LEDs for output state 4 membrane keys

Operating conditions Operating temperature Operating humidity

Design and materials Front dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Display digit height [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring

'H' 96x48 panel 90x42 98 9 300 IP54 / IP20 IP65 plastic plug-in terminals

-10...65 °C 0...85 %RH 'V' 48x96 panel 42x90 98 10 300 IP54 / IP20 IP65 plastic plug-in terminals

Instead of a chosen standard input Provides loop supply voltage - 24 VDC (only w/ isolated power supply) pH input is available ONLY for the 1st channel. The 2nd channel must be for temperature correction and/or control (Pt100: -19.9...99.9 °C). (4) Ask for availability! (2) (3)

Ordering code

RT180 - G0.G1.G5G5.G9'9" - #1.#2

Code Feature or option

Code values (5,6)

Variant

N - standard (w/ programmable inputs), D - for temperature difference control , P - for pH control (3,5), R - for relative humidity control (5,6), Z - other on request (4)

G0

Case (front size)

H - 96x48 mm, V - 48x96 mm

G1

Power supply

A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

G5

Relay output

X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate

G9'

Serial interface

X - none, B - RS485 (4)

G9"

Protocol

A - ASCII, C - ASCII for "PolyMonitor"

#1

Increased front protection

X - none, P - IP65 front protection

#2

Customer specified input signal

X - none, Z - custom linear signal (specify!)

(5) (6)

(1)

Variants 'P', 'D', and 'R' have FIXED control algorithm that cannot be altered by the user. The default control algorithm is ON/OFF – the same as in the standard variant. The input types of both channels are fixed to Pt100 with fixed input ranges.

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org

COMECO reserves the right of changing specifications without prior notice!

(1)


process controllers Programmable Controller RT390 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

Extremely flexible – unlimited range of applications User-programmable structure by ready-made blocks Powerful self-testing capabilities May be used as pH and RH controller Wide range of control algorithms and alarm types Bumpless Auto/Manual change-over Up to 5 inputs and 5 outputs Digital interface for network operation

RT390 is a compact microprocessor-based controller with user programmable internal structure and very wide range of application. It can be equipped with up to 3 analog and 2 discrete inputs and up to 3 relays and 2 analog outputs and can accept a whole variety of input signals including temperature, relative humidity, flow, pressure, pH, etc. Electromechanical relays, solidstate relays, or current or voltage analog outputs may be installed as control, alarm, or limit comparators. Each relay output may be programmed as time or frequency proportional or as a simple ON/OFF. The 3 analog inputs available allow special applications like positioning control, cascade controllers, pH control (with temperature compensation), etc. The internal structure consists of up to 15 functional blocks. Each functional block may calculate one of the 24 standard functions. Custom defined functions may be added. Bumpless auto/manual changeover is another feature. Network functions and hierarchical control are available with serial interface installed. Keyboard locking is possible by connection of a switch to one of the digital inputs.

Technical specifications Pt100; 3-wire Pt500; 3-wire Pt1000; 3-wire Cu53; 3-wire Cu100; 3-wire Ni100; 3-wire Other RTD Thermocouple "B" Thermocouple "D" Thermocouple "E" Thermocouple "J" Thermocouple "K" Thermocouple "L" Thermocouple "L - GOST " Thermocouple "N" Thermocouple "R" Thermocouple "S" Thermocouple "T" Thermocouple "U" Other thermocouple Linear voltage (Rin ≥ 1 GΩ) (1,2) Custom linear voltage (1,2) Linear current (Rin ≤ 10 Ω) (1,2) Custom linear current (1,2) Linear resistive (1) Linear potentiometer (1) pH input (Rin ≥ 10 TΩ) ORP input (Rin ≥ 10 TΩ) Sub-range selection

Digital inputs Input signal type Limitations Functions

Relay outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Output function Control algorithms and alarm limits Set point (1) (2) (3)

(up to 3 inputs) -200...200 (850) °C -200...200 (850) °C -200...200 (850) °C 0...180 °C -200...200 °C -60...200 °C min. -200...max. 850 °C 200...1820 °C 400...2300 °C -270...1000 °C -210...1200 °C -270...1370 °C -200...900 °C -200...900 °C -270...1300 °C -50...1700 °C -50...1700 °C -270...400 °C -200...600 °C up to 2000 °C 0...2 V, 0...5 V, or 0...10 V 0...max. 10 V 0(4)...20 mA 0...max. 50 mA 0...Rp ≥ 50 Ω 0...Rp ≥ 5 kΩ 0.00...14.00 pH -1000...+1000 mV programmable (up to 2 inputs) contact, TTL, NPN, or PNP Uin. max. ≤ 40 VDC programmable, in combination with certain blocks (up to 3 outputs) 5A/250V w/ NO contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF, time-proportional, or frequency-proportional (3) programmable, according to selected block types within input range limits

Analog outputs

(up to 2 outputs)

Current output Voltage output Other on request Output function Output range

0(4)...20 mA DC (RLOAD ≤ 400 Ω) 0...2/ 5/ 10 VDC (RLOAD ≥ 2/ 5/ 10 kΩ) max. 20 mA or 10 V retransmission / control user-programmable

Digital interface Output type Output function

RS232 or RS485 network, operator station, or hierarchical control

Accuracy Measurement error Temperature drift Calibration Cold junction compensation

0.4% from span 0.005% from span for 1 °C automatic software automatic hardware

Power supply Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption

230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 3 VA

Indication and controls Digital display LEDs Keyboard

4 LCD or LED indicators, 13 mm with programmable decimal point 3 LEDs for relay output state, LED for auto/manual mode 4 membrane keys

Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity

-10...65 °C 0...85 %RH -20...65 °C 0...95 %RH, non-condensing

Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals

plastic in 93x45 mm panel cut-out screw terminals 96x48(front)x125 mm 120 mm max. 350 g IP54 / IP20

The correspondence (mapping) of the input signal with displayed value ranges is user programmable. Provides 12...24 VDC / 30 mA supply for external transmitter on one of the linear voltage or current outputs Three types of frequency proportional outputs are available (user programmable). Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org

COMECO reserves the right of changing specifications without prior notice!

Analog inputs


process controllers

Programmable structure blocks PID ON/OFF controller ON/OFF duplex controller Positioning control Control error calculation Constant Adder Gain Attenuator Multiplier Divider Linear transformation (mapping) Low pass filter Saturation Dead band "Window" type alarm Inverted "window" type alarm High limit alarm Low limit alarm Timer Generator Time controlled multiplexer Discrete input controlled multiplexer Very long period PWM output Selectable constant (set-point unit) RH measurement by "wet" and "dry" bulb method PID with 2 inputs

Ordering code

industrial PID with anti-windup integration (4 parameters) ON/OFF control (1 parameter) ON/OFF duplex (heating/cooling) control (3 parameters) 2-speed positioning control for motorized valves (4 parameters) compares set point and measured value (1 parameter) constant value (1 parameter) adds 2 signals multiplies input signal by a constant (1 parameter) divides input signal by a constant (1 parameter) multiplies the values of the 2 input signals divides the values of the 2 input signals translates input signal range X1…X2 into output range Y1…Y2 (4 parameters) 3rd order Butterworth low pass filter (no ripple step response) (4 parameters) limits output signal between lower and upper limits (2 parameters) output signal is zero when input is within the dead band (1 parameter) output is active while input is within alarm limits (2 parameters) output is active while input is outside alarm limits (2 parameters) output is active while input above alarm limit (1 parameter) output is active while input below alarm limit (1 parameter) generates a pulse depending on input signal (2 parameters) controlled pulse generator (4 parameters) switches 1 of the 2 input signals to the output at time intervals (2 parameters) switches 1 of the 2 input signals to the output controlled by a discrete input forms PWM signal with time period of up to 9999 s (3 parameters) outputs one of 4 selected constants; controlled by the state of 2 discrete inputs forms signal proportional to RH value from 2 temperature inputs PID module with 2 inputs (input #1 - PV, input #2 - SP)

RT390 - G1.G2.G5G5G5.G6'6"G6'6"G6'6".G7G7.G9'9".G11G11

Code Feature or option

Code values A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

G1

Power supply

G2

Display

A - LCD, C - LED

G5

Relay output

X - none, A - relay NO, J - for external SSR, M - isolated MOS gate

G6'

Input signal

X - none, B - thermoresistance, C - thermocouple, D - linear, Z - other on request

G6"

Sensor

RTD

D - Pt100, F - Pt500, G - Pt1000, H - Cu53, K - Cu100, M - Ni100, Z - other

T/C

B - "B", D - "D", E - "E", J - "J", K - "K", L - "L" , M - "L-GOST", N - "N", R - "R", S - "S", T - "T", U - "U", Z - other

linear

B - 0...20 mA, C - 4...20 mA, H - 0...2 V, I - 0...5 V, K - 0...10 V, L - resistive, 0...Rp, M - potentiometer, 0...Rp, N - pH, O - ORP, Z - other

Discrete input

X - none, A - contact, E - NPN, F - PNP, G - TTL

G9'

Serial interface

X - none, A - RS232, B - RS485

G9"

Protocol

B - RT390, D - RT390 for "PolyMonitor"

G11

Analog output

X - none, E - 0…20 mA, F - 4…20 mA, H - 0…2 V, I - 0...5 V, K - 0...10 V, Z - other on request

COMECO reserves the right of changing specifications without prior notice!

G7

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org


level control equipment Level Controller LC05 ♦ ♦ ♦ ♦ ♦ ♦ ♦

Operates with conductive or non-conductive liquids Contact or resistive input Panel mounting Controls level between 2 electrodes with 1 relay output Tank supply or drainage control State indication Low cost

LC05 is a low-cost level controller for supply or drainage level control. Through its relay output, this device directly controls electrical pumps, valves, etc. and may be used either for tank emptying (drainage) or tank filling (supply). Two versions are available employing different methods for level measurement: - LC05 with resistive input., i.e. measuring electrical conductivity of the liquid between electrodes or between electrode and metal tank body, applicable for liquids with relatively high conductivity that are normally used in chemical, paper, food, wine, biotechnological industries, etc; - LC05 with electrical contact input, monitoring float state using magnetic or electromechanical float switches and applicable for various non-conductive liquids or cases of heavy condensation, vaporization, or foaming, such as in heating and water supply installations, etc. LC05 level controller is based on high-tech specialized electronic circuits that guarantee accuracy and stability, prevent electrolytic polarization, and ensure stable operation.

Technical specifications Input

Power supply passive electrical contact ≤ 50 Ω ≥ 500 kΩ conductive electrodes ≤ 50 kΩ ≥ 1…10 MΩ 18 VAC as requested

Contact - ON resistance - OFF resistance Resistive (1) - activation threshold (2) - release threshold (3) - probe voltage Input type

Output Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm

5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF

Indication LED for power ON, LED for output state

LEDs

Mains supply voltage SMPS voltage (4) Isolated low voltage Consumption

230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC (4) or 24 VAC max. 2 VA

Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity

-10...65 °C 0...85 %RH -20...65 °C 0...95 %RH, non-condensing

Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals Increased front IP (option)

plastic in 42x90 mm panel cut-out plug-in terminals 48x96(front)x107 mm 98 mm max. 400 g IP54 / IP20 IP65

(1)

Measures liquid resistance between measuring electrode and reference electrode (tank body) Maximum threshold resistance of activation at reaching (exceeding) the level Minimum threshold resistance of release at falling below the level (4) Ask for availability! (2) (3)

LC05 - G1.G5.G7 - #1

Code Feature or option

Code values

Variant

F - for supply control, E - for drainage control

G1

Power supply

A - 230 VAC, B - 115 VAC, C - 90…250 V (4), Q - 12…24 V, isolated (4), R - 24 VAC

G5

Relay output

C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate

G7

Input

A - contact (float), B - resistive (conductivity cell)

#1

Increased front protection

X - none, P - IP65 front protection

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code


level control equipment Programmable Level Controller LC1x ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

With up to 3 relay outputs, for up to 3 levels (independent) May control 2 dependent levels plus alarm Threshold adjustment option Tank supply and drainage control Input from conductivity-cell level electrodes Indication for reached level Panel or DIN-rail mounting Low cost

LC1x is a low-cost electronic level controller available for DIN-rail and panel mounting. It employs measurement of the electrical conductivity of the liquid between electrodes or between electrode and metal vessel case and is applicable for liquids with relatively high conductivity that are normally used in chemical, paper, food, wine, biotechnological industries, etc. The LC10 variant allows monitoring 1 or 2 fixed levels, and LC11 can monitor 1, 2, or 3 fixed levels, and a corresponding relay is activated or deactivated when each level is reached (drainage / supply control). Besides signaling reached level, the output relays may also be used for controlling electrical actuators. The direction of relay action at reached level as well as the connection (dependence) between levels is user-selectable. The device can also be configured as a drainage or supply level controller with alarm relay. A high-tech microprocessor circuit guarantees accuracy and stability, prevents electrolytic polarization, and ensures stable operation. A possibility to adjust output activation threshold as well as an LED indication makes the LC1x level controller a solution for a wide range of level related problems.

Technical specifications Input

Power supply

Input type (1)

resistive, from conductivity cell electrodes 10…1000 kΩ 10…2000 kΩ max. 5000 pF by trimmers on front panel jumper selectable (3) each level controls a relay 1 relay, controlled by 2 levels (up to 3 relay outputs) 5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF jumper selectable (3)

- activation threshold - release threshold Input wiring capacitance Threshold adjustment Operation modes: - independent levels - dependent levels

Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Drainage/supply control

Indication LED for power ON (2), 3 LEDs for output state (4), 3 LEDs for reached levels

LEDs

Mains supply voltage SMPS voltage (5) Isolated low voltage Consumption

230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC (5) or 24 VAC max. 2 VA

Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity

Design and materials Dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) (6) Case material Wiring

-10...65 °C 0...85 %RH -20...65 °C 0...95 %RH, non-condensing 'V' 48x96(front)x107 panel 42x90 98 500 IP44 / IP20 IP65 plastic plug-in terminals

'R' 70x110x58 DIN-rail 53 500 IP20 plastic plug-in terminals

(1)

Measures liquid resistance between measuring electrode and reference electrode (tank body) Available ONLY for case 'V' Factory settings: 3 independent levels with drainage action; different factory settings are available on request. (4) Available ONLY for case 'R' (5) Ask for availability! (6) Not available when threshold-adjustment trimmers are mounted! (2)

Ordering code

LC1 - G0.G1.G5G5G5.G7G7G7 - #1.#2 (7)

Code Feature or option

0 - for up to 2 levels, with 2 relay outputs, 1 - for up to 3 levels, with 3 relay outputs

G0

Case

V - for panel mounting, R - for DIN-rail mounting

G1

Power supply

A - 230 VAC, B - 115 VAC, C - 90…250 V (5), Q - 12…24 V, isolated (5), R - 24 VAC

G5

Relay output

X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate

G7

Input

X - none, B - resistive (conductivity cell)

#1

Threshold adjustment

#2 (7)

Code values

Variant

Increased front protection

X - none, A - threshold-adjustment trimmers mounted (6)

X - none, P - IP65 front protection

G5G5.G7G7 for variant '0'

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(3)


level control equipment Programmable Level Controller LC1x ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

With up to 3 relay outputs, for up to 3 levels (independent) May control 2 dependent levels plus alarm Threshold adjustment option Tank supply and drainage control Input from conductivity-cell level electrodes Indication for reached level Panel or DIN-rail mounting Low cost

LC1x is a low-cost electronic level controller available for DIN-rail and panel mounting. It employs measurement of the electrical conductivity of the liquid between electrodes or between electrode and metal vessel case and is applicable for liquids with relatively high conductivity that are normally used in chemical, paper, food, wine, biotechnological industries, etc. The LC10 variant allows monitoring 1 or 2 fixed levels, and LC11 can monitor 1, 2, or 3 fixed levels, and a corresponding relay is activated or deactivated when each level is reached (drainage / supply control). Besides signaling reached level, the output relays may also be used for controlling electrical actuators. The direction of relay action at reached level as well as the connection (dependence) between levels is user-selectable. The device can also be configured as a drainage or supply level controller with alarm relay. A high-tech microprocessor circuit guarantees accuracy and stability, prevents electrolytic polarization, and ensures stable operation. A possibility to adjust output activation threshold as well as an LED indication makes the LC1x level controller a solution for a wide range of level related problems.

Technical specifications Input

Power supply

Input type (1)

resistive, from conductivity cell electrodes 10…1000 kΩ 10…2000 kΩ max. 5000 pF by trimmers on front panel jumper selectable (3) each level controls a relay 1 relay, controlled by 2 levels (up to 3 relay outputs) 5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF jumper selectable (3)

- activation threshold - release threshold Input wiring capacitance Threshold adjustment Operation modes: - independent levels - dependent levels

Outputs Relay electromechanical Solid state relay MOS gate Output for external SSR Control algorithm Drainage/supply control

Indication LED for power ON (2), 3 LEDs for output state (4), 3 LEDs for reached levels

LEDs

Mains supply voltage SMPS voltage (5) Isolated low voltage Consumption

230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC (5) or 24 VAC max. 2 VA

Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity

Design and materials Dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) (6) Case material Wiring

-10...65 °C 0...85 %RH -20...65 °C 0...95 %RH, non-condensing 'V' 48x96(front)x107 panel 42x90 98 500 IP44 / IP20 IP65 plastic plug-in terminals

'R' 70x110x58 DIN-rail 53 500 IP20 plastic plug-in terminals

(1)

Measures liquid resistance between measuring electrode and reference electrode (tank body) Available ONLY for case 'V' Factory settings: 3 independent levels with drainage action; different factory settings are available on request. (4) Available ONLY for case 'R' (5) Ask for availability! (6) Not available when threshold-adjustment trimmers are mounted! (2)

Ordering code

LC1 - G0.G1.G5G5G5.G7G7G7 - #1.#2 (7)

Code Feature or option

0 - for up to 2 levels, with 2 relay outputs, 1 - for up to 3 levels, with 3 relay outputs

G0

Case

V - for panel mounting, R - for DIN-rail mounting

G1

Power supply

A - 230 VAC, B - 115 VAC, C - 90…250 V (5), Q - 12…24 V, isolated (5), R - 24 VAC

G5

Relay output

X - none, C - relay NO/NC, D - SSR, J - for external SSR, M - isolated MOS gate

G7

Input

X - none, B - resistive (conductivity cell)

#1

Threshold adjustment

#2 (7)

Code values

Variant

Increased front protection

X - none, A - threshold-adjustment trimmers mounted (6)

X - none, P - IP65 front protection

G5G5.G7G7 for variant '0'

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(3)


level control equipment Level Controller LC20 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

Operates with conductive or non-conductive liquids Contact or resistive input Rail mounting Optional threshold adjustment Controls level between 2 electrodes with 1 relay output Tank supply or drainage control State indication Low cost

LC20 is a low-cost electronic level controller/indicator for rail mounting. Through its relay output, this device directly controls electrical pumps, valves, etc. and may be used either for tank emptying (drainage) or tank filling (supply). Two versions are available employing different methods for level measurement: - LC20 with resistive input., i.e. measuring electrical conductivity of the liquid between electrodes or between electrode and metal tank body, applicable for liquids with relatively high conductivity that are normally used in chemical, paper, food, wine, biotechnological industries, etc; - LC20 with contact input, accepting signals from contact level switches (float, optical, etc.), applicable for various non-conductive liquids or cases of heavy condensation, vaporization, or foaming, such as in heating and water supply installations, etc. An optional output activation threshold adjustment via potentiometer on the front panel provides better adaptation to liquids with different conductivity for both versions.

Technical specifications Input

Power supply

Contact (1) - ON resistance - OFF resistance Resistive (2) - activation threshold (3) - release threshold (4) - probe voltage Input type Threshold adjustment (option)

passive electrical contact ≤ 50 Ω ≥ 500 kΩ conductivite electrodes ≤ 50 kΩ ≥ 1…10 MΩ 18 VAC as requested via front-panel potentiometer, 10...50 kΩ

Output Relay electromechanical Solid state relay (1) MOS gate (1) Output for external SSR Control algorithm

5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF

Indication LED

LED for output state

Mains supply voltage SMPS voltage (1) Isolated low voltage Consumption

230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC (1) or 24 VAC max. 2 VA

Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity

-10...65 °C 0...85 %RH -20...65 °C non-condensing, 0...95 %RH

Design and materials Case material Mounting Wiring Dimensions Weight Protection, front/terminals

plastic on 35 mm DIN rail screw terminals 45x78x124 mm max. 400 g IP40 / IP20

(1)

Ask for availability! (2) Measures liquid resistance between measuring electrode and reference electrode (tank body) (3) Maximum threshold resistance of activation at reaching (exceeding) the level (4) Minimum threshold resistance of release at falling below the level

LC20 - G1.G5.G7 - #1

Code Feature or option

Code values

Variant

F - for supply control, E - for drainage control

G1

Power supply

A - 230 VAC, B - 115 VAC, C - 90…250 V (1), Q - 12…24 V, isolated (1), R - 24 VAC

G5

Relay output

C - relay NO/NC, D - SSR (1), J - for external SSR, M - isolated MOS gate (1)

G7

Input

A - contact (float) (1), B - resistive (conductivity cell)

#1

Threshold adjustment

X - none, A - potentiometer for threshold adjustment

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code


level control equipment Level-Switch Isolating Unit LCI2x ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

Isolating amplifier with up to 2 channels Operates with ATEX level switches series LCSFT Provides 2.5 V sensor voltage Isolated AC/DC power supply Output and power state indication 750 V isolation Rail mounting Low cost

The LCI2x isolating amplifier is a low-cost isolating unit with robust plastic case for rail mounting, especially designed to be used with COMECO’s ATEX-approved float level switches series LCSFT. The isolator operates with a wide range of power supply voltages and provides an isolated sensor voltage of only 2.5 V. The internal optical isolator and pulse transformer ensure an isolation level of 750 V. LCI2x can be ordered either with 1 input and 1 relay output, or, when the application requires controlling high and low level points, with 2 inputs and 2 corresponding output relays. Up to 3 LEDs provide convenient indication of the output and power state. The excellent price-toperformance ratio makes the remote isolating unit LCI2x a very useful device for low-cost Ex applications in liquid level control.

Technical specifications Inputs

(1 per channel) OFF/ON, resistive: 20/10 kΩ ± 10% 2.5 VDC ≤ 63 µA 750 VAC for 1 min

Input signal Input (sensor) voltage Input (sensor) current Isolation from output

Outputs

(1 per channel)

Relay electromechanical Solid state relay (1) MOS gate (1) Output for external SSR Switching hysteresis

5A/250V w/ NO contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ≤ 0.01% of span

Indication up to 2 red LEDs for output state, green LED for power ON

LEDs (1)

Isolated low voltage SMPS voltage (1) Isolation from input Consumption

8...28 VAC/DC 90…250 VAC/DC 750 VAC for 1 min max. 2 VA

Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity

-10...65 °C 0...85 %RH -20...65 °C non-condensing, 0...95 %RH

Design and materials Case material Mounting Wiring Dimensions Weight Protection, front/terminals

plastic on 35 mm DIN rail plug-in terminals 35x110x58 mm max. 250 g IP54 / IP20

Ask for availability!

Ordering code

LCI2 - G1.G5 (2)

Code Feature or option

Code values

Variant

0 - single-channel, 2 - double-channel

G1

Power supply

C - 90…250 V (1), Q - 8…28 V, isolated

G5

Relay output

A - relay NO, D - SSR (1), J - for external SSR, M - isolated MOS gate (1)

G5G5 for variant '2'

COMECO reserves the right of changing specifications without prior notice!

(2)

Power supply

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


process controllers Field Mounting ON/OFF Controller RT38-Y ♦ ♦ ♦ ♦ ♦ ♦ ♦

Ready to incorporate temperature or other sensor Direct in-process mounting Relay control output switching power supply Semi-universal input Mains or low-voltage power supply Fully programmable parameters IP66 protection class

RT38-Y is a programmable ON/OFF controller, designed for direct control over temperature or other processes when coupled with a TSEC temperature probe or other sensor. The device is equipped with a 3-digit LED display and a control relay. Available are 2 universal-input versions – RTD (for 7 selectable Ptx and 4 Cux sensor types) and T/C (for 3 selectable thermocouples) – as well as versions for linear current and voltage signals. The controller can be ordered either for mains or for low-voltage power supply and allows an automatic software compensation of line resistance and cold junction temperature. The display-to-input correspondence (in case of linear input), decimal point position, temperature measurement unit, and offset value are also programmable. RT38-Y is enclosed in a robust plastic box with IP66 connector and enables easy and firm sensor assembly. Thanks to its design, RT38-Y is widely applicable in cases, in which direct control of electrical actuators is required.

Technical specifications Input

Power supply

RTD, DIN (w=1.385); 3-wire RTD, GOST (w=1.391); 3-wire RTD measurement range Thermocouple "T" Thermocouple "J" Thermocouple "K" Linear voltage 0...10 V Linear current 0(4)...20 mA Two-wire external transmitter RTD or T/C type selection Decimal point selection Temperature measurement unit

Pt50, Pt100, Pt500, Pt1000 Pt46, Pt50, Pt100, Cu50, Cu100 -100...600 °C -40...400 °C -20...999 °C -20...999 °C -199...999, programmable -199...999, programmable 4...20 mA (1) programmable programmable °C or °F, programmable

Output

Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage External mains transformer (2) Consumption

230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC 9(12) VAC max. 1.5 VA

Indication and controls 3 LED indicators, 14 mm LED for output state 3 membrane keys

Digital display LEDs Keyboard

Operating conditions

Relay electromechanical Solid state relay MOS gate Output for external SSR Direct power supply switching Control algorithm Set point Alarms

5A/250V w/ NO contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA OFF - open circuit; ON - supply voltage ON/OFF within input range limits programmable

Accuracy Measurement error Temperature drift Cold junction compensation

0.3% from span 0.02% from span for 1 °C automatic, -10...80 °C

Ambient temperature Ambient humidity

-10...65 °C 0...85 %RH

Design and materials Case material Controller mounting Probe mounting Power wiring Probe wiring Dimensions Protection, enclosure/terminals

ABS plastic on probe top or free (3) axial (box bottom) or radial (connector opposite) 4-pin М12 connector, always on top 4-pin М12 connector or direct (4) 92x92x60 mm IP66 / IP65

Provides loop supply voltage - 24 VDC (only w/ isolated power supply). Ordered separately (see 'Accessories'). (3) May be mounted on plate or rail by special accessories, which are ordered separately (see 'Accessories'). (4) Order separately! Suitable for assembly are temperature probes type TSEC w/ head connection M12x1.5 (see 'Temperature Probes'). (2)

Ordering code

RT38 - Y.G1.G5.G6.G12'12"

Code Feature or option

Code values

G1

Power supply

A - 230 VAC, B - 115 VAC, C - 90…250 V, E - 9(12) VAC w/ external transformer (2), P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

G5

Output

X - none, A - relay NO, D - SSR, J - for external SSR, M - isolated MOS gate, Y - power supply

G6

Input

B - RTD (programmable), C - thermocouple (programmable), D - 0(4)…20 mA, DK - 0…10 V

G12'

Probe connection

I - direct (4), E - via connector

G12"

Probe position

A - axial, R - radial

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(1)


level control equipment Float Level Probe with Controller LCF ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

2-level control with 1 relay output User-selectable filling or drainage control Various float types 135 °C maximum liquid temperature Mains or low-voltage power supply Vertical adjustment option ATEX certified Ex version available Cost saving solutions

COMECO's level controller LCF combines a 2-point float-type level probe LCSFC and a standard LC05 controller installed inside an ABS protective enclosure with IP66. Large variety of versions based on different plastic and stainless steel floats is available. Floats with different dimensions and specific gravity are available for liquid density down to 0.5 g/cm3, temperature up to 135 °C, and pressure up to 50 bar. Various process connections as well as an option for vertical adjustment are available. LCF can be used for liquid filling or emptying control by switching on and off vessel supply or drainage devices such as pumps and magnet valves. The controller allows the operator to select relevant output relay action for either supply or drainage control. Thanks to the compact combination of probe and in-head controller, LCF can be very useful for building cost-saving level control applications.

Probe specifications LCF

Model B

A

L2

L0

L1

LX

Vertical Adjustment 10% of L0

Specifications Float type

N1

P1

P10

P2

P3

P4

S0/S1/S7/S10

S2

S3

S4

S5

S6

Float material Liquid density [g/cm3]

NBR > 0.80

PP > 0.60

PP > 0.72

PP > 0.60

PP > 0.50

PVDF > 0.70

SS > 0.80

SS > 0.70

SS > 0.65

SS > 0.55

SS > 0.55

SS > 0.50

Ext. tube diameter ('d')

8 mm

8 mm

10 mm

12 mm

16 mm

16 mm

10 mm

14 mm

14 mm

100...1500 100...2500

Min. end-to-float distance ('A') [mm]

23

21

15

37

47

47

22/25/25/29

34

40

39

50

70

Min. float running distance ('B') [mm]

27

24

17

52

62

62

25/30/30/34

40

57

54

75

110

12 bar

30 bar

30 bar

10 bar

min. 2"

min. 2"

-20…100 °C

Max. process pressure Wetted parts

0 bar

5 bar

5 bar

3 bar

min. ½" (M20)

min. 1" (M33)

min. 1" (M33)

min. 1" (M33)

Process connection

-20…80 °C

100...1000

16/18 mm 16/18 mm

100...1000

Process temperature

200...4000

8 mm

Probe length ('L0') [mm]

100...2000 200...3000 200...3000 300...4000 300...5000

-30…125 °C 3 bar

-20…135 °C

2 bar 8/10/30/50 bar 30 bar stainless steel or plastic

min. 1 ¼"

min. 1" (M33)

min. 1½"

min. 3" or flange

Controller specifications Input Input type

Power supply float position – low or high

Output Relay electromechanical Solid state relay (1) MOS gate (1) Output for external SSR Control algorithm Operation mode

8A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated 5…24 V, 30 mA ON/OFF, filling or emptying, user-selectable

Indication LEDs (1)

red LED for output state

Ask for availability!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

Mains supply voltage SMPS voltage (1) Isolated low voltage Non-isolated low voltage Consumption

230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC (1) or 24 VAC 24 VDC max. 2 VA

Operating conditions Ambient temperature Ambient humidity

-10...65 °C 0...85 %RH

Design and materials Case material Wiring Dimensions Protection class

ABS plastic screw terminals via PG9 cable glands 80x80x60 mm (w/o glands) IP66

COMECO reserves the right of changing specifications without prior notice!

A


level control equipment

Ordering code

LCF - G0.G1.G5.G6.G9.G10 - #1

Code Feature or option Power supply

A - 230 VAC, B - 115 VAC, C - 90…250 V (1), D - 24 VDC, non-isolated, Q - 12…24 V, isolated (1), R - 24 VAC

G1

Float

N1 - NBR, ø15x25, P1 - PP, ø24x22, P2 - PP, ø29x50, P3 - PP, ø38x60, P4 - PVDF, ø38x60, P10 - PP, ø29x11, S0 - stainless steel, ø25x25, S1 - stainless steel, ø28x28, S2 - stainless steel, ø41x38, S3 - stainless steel, ø45x55, S4 - stainless steel, ø52x52, S5 - stainless steel, ø73x73, S6 - stainless steel, ø75x108, S7 - stainless steel, ø30x28, S10 - stainless steel, ø30x32, S20 - stainless steel, ø22x40

G5

Relay output

G0

C - relay NO/NC, D - SSR (1), J - for external SSR, M - isolated MOS gate (1) (2)

G6

Operating lengths [mm]

L0/L1/L2

G9

Process connection

X - none, Q2 - M20x1.5, Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q13 - G1½", Q14 - G2", Q15 - 1" NPT, Q16 - 1½" NPT, Q17 - 2" NPT, Q21 - G3", Q22 - 3" NPT, Q25 - M33x2, Q27 - G1¼", Q28 - 1¼" NPT, F - flange (specify!), Z - other (specify!)

G10

Sheath material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404, M15 - 1.4362

#1

Vertical adjustment

X - none, A - vertical adjustment via stainless steel ferrule installed

Specify the exact length (step 50 mm) from the thread, flange, or box bottom to the respective contact according to the limits given in the specification table, strictly observing 'A' and 'B' minimum distances! 1st contact → 'L1'; e.g.: LCF - A.S1.C.500/50/200.Q12.M1

COMECO reserves the right of changing specifications without prior notice!

(2)

Code values

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


pressure and flow control equipment Flow Controller PSF21x ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

Excellent price-to-performance ratio Unique ultra-light-rotor technology Exceptional accuracy and reliability Operates with liquids with viscosity from 1 to 1000 CST Pulse output with 6000 pulses per liter of water Alarm/Control output with 2 programmable limits Local programmable LED display Chemically resistant variant available

PSF21x is a programmable flow controller designed for use with low-viscose clear or translucent liquids, transmitting IR light. The operating principle is based on the liquid volume measurement through light-weight rotor, IR sensor, and sophisticated electronics for measurement and control. The material types used (PVDF, Vectra®, Viton®, EPDM, etc.) have a good thermal (up to 90 °C) resistance. A special variant with increased chemical resistance also extends the controller application. Other ranges except the standard 0.5…20 l/min are available on request. PSF21x is equipped with a local 3-digit LED display and a hidden key for easy programming and flow monitoring. Output capabilities include TTL pulse output as well as PNP or NPN alarm output that activates when either of the programmable alarm limits is reached. PSF21x can be used as a flow meter, flow transmitter with pulse output, ON/OFF flow controller, or alarm unit suitable for water treatment and other applications.

Technical specifications Input

Local indicator

Liquid type

clear or translucent liquid transmitting IR light (1) 1...1000 CST 0.5...20 l/min (2)

Liquid viscosity Flow range

Measurement accuracy ± 1.00% 1.00% max. ± 0.30%

Accuracy Interchangeability Reproducibility

Outputs Pulse output Sensitivity Alarm output Alarm type Alarm function

TTL, 100...2000 Hz, max. 0.5 mA 6000 pulses per liter of water PNP/NPN, max. 100mA/40V, NO 'window' ON/OFF

Power supply 18...30 VDC 2 Vp-p at 50 Hz max. 200 mA

Supply voltage Admissible variations Consumption (2)

Operating conditions Process temperature Ambient temperature Process pressure

Design and materials Wetted parts Seals Case material Mounting Process connection Wiring Dimensions Weight Protection class (housing)

PSF210 POM, PVDF, Viton®, Vectra®, EPDM NBR POM free 2 x G1/2”, male 3(4)-wire PVC cable 105x60x45 mm max. 200 g IP67

-20...90 °C -10...65 °C max. 12 bar PSF211 SS, PVDF, Viton®, Vectra®, EPDM PTFE POM free 2 x G1/2”, male 3(4)-wire PVC cable 105x60x45 mm max. 250 g IP67

Liquid medium must be compatible with wetted part and seal materials! Other ranges are available on request.

Ordering code

PSF21 - G5.G9.G12

Code Feature or option

Code values

Variant

0 - standard, 1 - chemically resistant (3)

G5

Relay output

E - NPN, F - PNP

G9

Pulse output

X - none, P - 6000 TTL pulses/l

G12

Cable length [m] and type

1PV…10PV - PVC

(3)

3 LED indicators, 10 mm 0.1 l/min 1s 0.01% from span for 1 °C for alarm event 1 hidden key

Limited with wetted part and seal material resistance!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(1)

Digital display Display resolution Display refresh Temperature drift LED indicator Keyboard


timers and counters Dial-type Analog Timer CT02 ♦ ♦ ♦ ♦ ♦ ♦

Very low cost Wide time range 48x48 mm or 96x48 mm DIN-sized front panel 8 operating modes Main and auxiliary relays Panel or rail mounting

The CT02 timer is designed for time sequence control of electrical actuators. The time setting adjustment is done by rotating a dial on the front panel and the timing is started at power-on or by external 'start/stop' contact. Various modes of operation – on-delay, off-delay, pulse output, and cyclical output – are available. The operating modes as well as the time range (for variant 'S') can be selected via micro switches. The timer may be equipped with up to 2 relays – main timing relay and auxiliary relay, which is activated at power-on or simultaneously with the main relay. CT02 has no indication, is very easy to set and operate, and yet has all the main functions of a modern electronic timer.

Technical specifications Input

(1)

Indication and controls

Input type Input function

Times and modes Ranges (3) Dial multiplication coefficient Delay Output pulse Cyclic mode

Outputs Relay electromechanical Solid state relay (4) MOS gate Transistor gate (5) Output for external SSR Main (timer) relay Auxiliary relay

passive contact (NO) external 'Start/Stop' or front-panel 'Start/Stop' button (2) 'N' 'S' 1...10 s, 10...100 s, 0...1, 0...3, 0...6 1...10 min, 10...100 min - x1 s, x10 s, x1 min ON or OFF ON or OFF no yes no yes (up to 2 - main and auxiliary) 5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated open collector, 40mA/40V 12/24 V, 30 mA time operated activates at power-on (6)

Accuracy 1% (2% for 'N') from span 0.007% from span for 1 °C

Measurement error Temperature drift

LEDs Rotating dial Micro switches

LED for the time operated relay for time adjustment for mode selection and multiplication coefficient setting (7)

Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity

Design and materials Case material Mounting

230 VAC or 115 VAC 24…230 VAC/DC 24 VDC 24 VDC max. 2 VA

plastic 'H': in 93x45 mm panel cut-out; 'S': in 45x45 mm panel cut-out or on 35 mm DIN rail

Wiring: - for variant 'N' - for variant 'S' Dimensions: - for variant 'N'

Power supply Mains supply voltage (1) SMPS voltage (7) Isolated low voltage (1) Non-isolated low voltage Consumption

-10...65 °C 0...85 %RH -20...65 °C 0...95 %RH, non-condensing

- for variant 'S' Mounting depth Weight Protection, front/terminals

'H': screw terminals; 'S': socket UNDECAL (8) socket OCTAL (8) 'H': 96x48(front)x136 mm; 'S': 48x48(front)x102 mm 48x48(front)x95 mm 'H': 120 mm; 'S': max. 105 mm (w/ socket) max. 250 g IP40 / IP20

(1)

Only for variant 'N' Only for case 'H' For variant 'S', ranges are user selectable; for variant 'N', they are fixed and should be specified in customer order. (4) Ask for availability! (5) ONLY with isolated power supply! (6) For variant 'S', a mode may be selected when auxiliary relay operates TOGETHER WITH the main time operated relay. (7) Only for variant 'S' (8) Ordered separately (see 'Accessories') (2)

Ordering code

CT02 - G0.G1.G4.G5G5.G8

Code Feature or option

(9)

Code values

Variant

N - normal, S - simplified

G0

Case (front panel) (1)

S - 48x48 mm, H - 96x48 mm

G1

Power supply

A - 230 VAC (1), B - 115 VAC (1), D - 24 VDC, non-isolated, K - 24…230 V (7), Q - 24 VDC, isolated (1)

G4

Start/Stop

A - at power-on, C - from front-panel button (2), D - from input (1)

G5

Relay output

X - none (9), C - relay NO/NC, D - SSR (4), E - open collector NPN (5), J - for external SSR, M - isolated MOS gate

G8

Operating mode (1)

B - selectable, D - delay ON, E - delay OFF, F - output pulse, G - cyclic

A main relay MUST be installed!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(3)


timers and counters Dial-type Analog Timer CT02 ♦ ♦ ♦ ♦ ♦ ♦

Very low cost Wide time range 48x48 mm or 96x48 mm DIN-sized front panel 8 operating modes Main and auxiliary relays Panel or rail mounting

The CT02 timer is designed for time sequence control of electrical actuators. The time setting adjustment is done by rotating a dial on the front panel and the timing is started at power-on or by external 'start/stop' contact. Various modes of operation – on-delay, off-delay, pulse output, and cyclical output – are available. The operating modes as well as the time range (for variant 'S') can be selected via micro switches. The timer may be equipped with up to 2 relays – main timing relay and auxiliary relay, which is activated at power-on or simultaneously with the main relay. CT02 has no indication, is very easy to set and operate, and yet has all the main functions of a modern electronic timer.

Technical specifications Input

(1)

Indication and controls

Input type Input function

Times and modes Ranges (3) Dial multiplication coefficient Delay Output pulse Cyclic mode

Outputs Relay electromechanical Solid state relay (4) MOS gate Transistor gate (5) Output for external SSR Main (timer) relay Auxiliary relay

passive contact (NO) external 'Start/Stop' or front-panel 'Start/Stop' button (2) 'N' 'S' 1...10 s, 10...100 s, 0...1, 0...3, 0...6 1...10 min, 10...100 min - x1 s, x10 s, x1 min ON or OFF ON or OFF no yes no yes (up to 2 - main and auxiliary) 5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated open collector, 40mA/40V 12/24 V, 30 mA time operated activates at power-on (6)

Accuracy 1% (2% for 'N') from span 0.007% from span for 1 °C

Measurement error Temperature drift

LEDs Rotating dial Micro switches

LED for the time operated relay for time adjustment for mode selection and multiplication coefficient setting (7)

Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity

Design and materials Case material Mounting

230 VAC or 115 VAC 24…230 VAC/DC 24 VDC 24 VDC max. 2 VA

plastic 'H': in 93x45 mm panel cut-out; 'S': in 45x45 mm panel cut-out or on 35 mm DIN rail

Wiring: - for variant 'N' - for variant 'S' Dimensions: - for variant 'N'

Power supply Mains supply voltage (1) SMPS voltage (7) Isolated low voltage (1) Non-isolated low voltage Consumption

-10...65 °C 0...85 %RH -20...65 °C 0...95 %RH, non-condensing

- for variant 'S' Mounting depth Weight Protection, front/terminals

'H': screw terminals; 'S': socket UNDECAL (8) socket OCTAL (8) 'H': 96x48(front)x136 mm; 'S': 48x48(front)x102 mm 48x48(front)x95 mm 'H': 120 mm; 'S': max. 105 mm (w/ socket) max. 250 g IP40 / IP20

(1)

Only for variant 'N' Only for case 'H' For variant 'S', ranges are user selectable; for variant 'N', they are fixed and should be specified in customer order. (4) Ask for availability! (5) ONLY with isolated power supply! (6) For variant 'S', a mode may be selected when auxiliary relay operates TOGETHER WITH the main time operated relay. (7) Only for variant 'S' (8) Ordered separately (see 'Accessories') (2)

Ordering code

CT02 - G0.G1.G4.G5G5.G8

Code Feature or option

(9)

Code values

Variant

N - normal, S - simplified

G0

Case (front panel) (1)

S - 48x48 mm, H - 96x48 mm

G1

Power supply

A - 230 VAC (1), B - 115 VAC (1), D - 24 VDC, non-isolated, K - 24…230 V (7), Q - 24 VDC, isolated (1)

G4

Start/Stop

A - at power-on, C - from front-panel button (2), D - from input (1)

G5

Relay output

X - none (9), C - relay NO/NC, D - SSR (4), E - open collector NPN (5), J - for external SSR, M - isolated MOS gate

G8

Operating mode (1)

B - selectable, D - delay ON, E - delay OFF, F - output pulse, G - cyclic

A main relay MUST be installed!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(3)


timers and counters 2-period Multifunctional Timer CT03 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

Fully programmable 2 time periods with 2 relay outputs Easy-to-set push-wheel switch External or power-on starting modes HOLD input Maximum time delay up to 999 min 4 operating modes 48x48 mm DIN-sized front panel

The CT03 timer is a low-cost microprocessor-based device for time sequence control with 2 adjustable time periods forming a time cycle, 3 sub-ranges, and 4 different timing modes. The push-wheel switch (BCD) on the front panel enables easy setting of the period duration and the 3-digit display indicates the current time, the parameters, or the operating mode. All modes of operation and parameters are user-programmable via front-panel keyboard. CT03 is also equipped with 2 contact inputs for external start and hold and 2 output relays with programmable action for timing control of processes through switching electrical actuators on and off. The extended features of CT03 simplify programming and process monitoring and make the timer a convenient solution to a wide range of timing related problems.

Technical specifications Inputs

Indication and controls

Input type Input START Input HOLD Input programming

NO contacts external closing contacts external closing contacts through keyboard

Times and modes

Digital display LEDs Keyboard Push-wheel switch

3 LED indicators, 10 mm 2 LEDs for relay state 2 membrane keys for easy value programming

Power supply

Ranges First period (t1) Second period (t2) Modes of operation Range selection Time selection Parameter programming Value adjustment

Outputs Relay electromechanical Solid state relay (3) MOS gate Transistor gate (4) Output for ext. SSR Relay K1 action Relay K2 action

0...99.9 s, 999 s, or 999 min after start depends on the operation mode up to 4 modes (1) programmable programmable through keyboard (2) by push-wheel switch (up to 2 relay outputs) 5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated open collector, 40mA/40V 5...24 V, 30 mA activates alternatively with t1 and t2 activates for total cycle time (t1+t2)

Accuracy 0.02% from span negligible

Measurement error Temperature drift

Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption

230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 2 VA

Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity

-10...65 °C 0...85 %RH -10...70 °C 0...95 %RH, non-condensing

Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals

plastic in 45x45 mm panel cut-out or on 35 mm DIN rail socket UNDECAL (5) 48x48(front)x95 mm 103 mm (w/ socket) max. 250 g IP54 / IP20

(1)

One-shut cycle mode; cyclic mode (repeated cycle); one-shut cycle mode (t2 - total cycle time); cyclic mode (t2 - total cycle time) Relay K1 action after start; relay K2 action in active period; inactive state of K1 and K2; specifies period adjusted by BCD; restart during action; automatic start at power-on Ask for availability! (4) ONLY with isolated power supply! (5) Ordered separately (see 'Accessories') (2)

Ordering code

CT03 - G1.G5G5

Code Feature or option

(6)

Code values

G1

Power supply

A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

G5

Relay output

X - none (6), C - relay NO/NC, D - SSR (3), E - open collector NPN (4), J - for external SSR, M - isolated MOS gate

At least one relay must be ordered!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(3)


timers and counters Analog Timer with Display CT04 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

Low cost 4-digit LED display Time setting via push-wheel switch Improved precision ON and OFF delay Controls main and auxiliary relay 48x48 mm DIN-sized front panel Panel or rail mounting

With its 48x48 mm DIN-sized front panel, the CT04 timer is especially suitable for building in machines and installations where compact size is important. A 4-digit LED display indicates the current time, and the delay is set by push-on wheels (BCD coders), which greatly simplifies the setting and improves accuracy. Equipped with 2 relay outputs – main and auxiliary relay – CT04 can be used for timing control (switching on and off) of various electrical actuators. The main relay is time operated, and the auxiliary relay is activated at power-on or simultaneously with the main relay. In spite of its simple design and low price, CT04 has all main functions of a modern electronic timer and can be widely used in industry and consumer goods.

Technical specifications Times and modes

Power supply

Range Time unit Mode of operation Timing start

Outputs Relay electromechanical Solid state relay (1) MOS gate Transistor gate (2) Output for external SSR Main (timer) relay Auxiliary relay

0.0...99.9 or 0...999 seconds or minutes on-delay or off-delay at power-on (up to 2 - main and auxiliary) 5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated open collector, 40mA/40V 12/24 V, 30 mA time operated activates at power-on or copies main relay

Accuracy 0.05% from span insignificant

Measurement error Temperature drift

Indication and controls 4 LED indicators, 9 mm 2 LEDs for relay state and time unit for easy time setting

Digital display LEDs Push-wheel switch

Mains supply voltage Isolated low voltage Non-isolated low voltage Consumption

230 VAC or 115 VAC 24 VDC 24 VAC or 24 VDC max. 2 VA

Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity

-10...65 °C 0...85 %RH -20...65 °C 0...95 %RH, non-condensing

Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals

plastic in 45x45 mm panel cut-out or on 35 mm DIN rail socket (3) OCTAL or UNDECAL (4) 48x48(front)x95 mm max. 103 mm (w/ socket) max. 250 g IP40 / IP20

(1)

Ask for availability! ONLY with isolated power supply! Ordered separately (see 'Accessories') (4) ONLY with auxiliary relay (2)

(3)

CT04 - G1.G5G5.G6.G8

Code Feature or option

(5)

Code values

Power supply

A - 230 VAC, B - 115 VAC, D - 24 VDC, E - 24 VAC, Q - 24 VDC, isolated

G5

Relay output

X - none (5), C - relay NO/NC, D - SSR (1), E - open collector NPN (2), J - for external SSR, M - isolated MOS gate

G6

Time range

LS - 0...99.9 s, HS - 0...999 s, LM - 0...99.9 min, HM - 0...999 min

G8

Operating mode

D - delay ON, E - delay OFF

G1

A main relay MUST be installed!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code


timers and counters Budget DIN-rail Digital Timer CT05 ♦ ♦ ♦ ♦ ♦ ♦

For low-cost applications Slim size 3 operating modes Up to 100 hour time delay Long relay life Easy setup and programming

CT05 is a DIN-rail mountable programmable time-delay relay designed for time sequence control of electrical actuators. The time delay can be adjusted from 0.1 s up to 100 h via a rotary switch and a trimming potentiometer on the front panel and the timing starts at power-on. Different modes of operation – on-delay, off-delay, and cyclical output – can be selected with the rotary micro switch. The timer is equipped with 1 relay output as well as a multi-function LED indicating power supply, relay, and failure status, timing and program modes. CT05 is very easy to set, program, and operate, and yet has all the main functions of a modern programmable timer.

Technical specifications Times and modes

Power supply

Ranges

0.1...1 s, 1...10 s, 0.1...1 min, 1...10 min, 0.1...1 h, 1...10 h, 10...100 h programmable (see table below)

Modes of operation

Output

Non-isolated SMPS voltage Non-isolated low voltage Consumption

24…230 VAC/DC 24 VAC/DC ± 10% max. 2 VA

Operating conditions

Output type Contact form and ratings Contact life cycles Initiate time Reset time

electromechanical relay NO/NC (SPDT), max. 5 A, max. 250 V 106 ≤ 350 ms ≤ 350 ms

Accuracy

Operating temperature Operating humidity Storage temperature Storage humidity

-20...65 °C 0...85 %RH -30...80 °C 0...95 %RH, non-condensing

Design and materials

Time accuracy Time repeatability

better than 0.5% of span better than 0.1% of span

Indication and controls LEDs Trimming potentiometer Rotary switch

LED for power ON, mode, and state for time adjustment and mode selection for range and mode selection

Mode

Case material Mounting Wiring Dimensions Weight Protection class

plastic on 35 mm DIN rail screw terminals 18x90x58 mm max. 70 g IP20

Delay ON

Cyclic delay ON

Pulsed delay ON

Delay OFF

Cyclic delay OFF

Pulsed delay OFF

U - power supply voltage R - relay output T - time delay

Ordering code

CT05 - G1

Code Feature or option G1

Power supply

Code values K - 24…230 V, non-isolated, P - 24 VAC/DC, non-isolated

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

LEGEND:


timers and counters 2-channel Programmable Timer CT12 ♦ ♦ ♦ ♦ ♦ ♦ ♦

2 programmable timers in one case Up to 2 freely programmable relay outputs Up to 10 programmable periods per channel 2 programs or 1 longer one 4-digit LED display Start from external input or from keyboard Maximum time per period 9999 minutes

CT12 is a programmable device for timing control incorporating 2 independent timers in one case. Two relay outputs (one per channel) control electrical actuators by switching them on and off. A time sequence that may consist of up to 10 ON or OFF periods, each with different duration, may be programmed for each output (channel). The device may be used as a single channel timer with up to 20 period time sequence. After a start command from the featured external input or the front-panel keyboard, the time sequence may be run once or repeated endlessly. A 4-digit digital display indicates current time and – during programming – parameter values, and the keyboard enables setting of all modes and parameters of time sequence. The CT12 timer is easy to program and – with its rich set of features – widely applicable.

Technical specifications Inputs

Indication and controls

Passive contact input Active signal input External 'Start/Stop' Input setting (2)

NO contacts voltage, max. 40 VDC starts and stops time sequence (1) programmable

Times and modes

Keyboard

4 LED indicators, 10 mm 2 LEDs for output state, 2 LEDs for indicated channel 4 membrane keys

Power supply

Time sequences Time periods Period duration range Time setting Output state setting Mode selection Measurement unit selection

Outputs

Digital display LEDs

(3)

Relay electromechanical Solid state relay MOS gate Transistor gate (4) Output for external SSR Relay function

1 per channel up to 10 per channel or 20 in single-channel mode 0.01 s...9999 min programmable for each period programmable for each period programmable programmable (up to 2 relay outputs) 5A/250V w/ NO/NC contact 1A/250 VAC 0.1A/60V, optically isolated open collector, 40mA/40V 12/24 V, 30 mA ON and OFF, acc. to time sequence

Accuracy 0.7% insignificant

Measurement error Temperature drift

Mains supply voltage (5) SMPS voltage Isolated low voltage Non-isolated low voltage Consumption

230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC (5) 12…24 VAC/DC max. 3 VA

Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity

-10...65 °C 0...85 %RH -20...65 °C 0...95 %RH, non-condensing

Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals Increased front IP (option) (5)

plastic in 93x45 mm panel cut-out screw terminals 96x48(front)x125 mm 120 mm max. 350 g IP54 / IP20 IP65

(1)

Time sequence start and stop may be initiated through external input or keyboard. Select the active front of external signal When only the single-channel mode will be used (20-period time sequence), only one (the first) relay may be ordered. (4) ONLY with isolated power supply! (5) Ask for availability! (2)

Ordering code

CT12 - G1.G5G5 - #1

Code Feature or option

Code values

G1

Power supply

A - 230 VAC (5), B - 115 VAC (5), C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC (5)

G5

Relay output (3)

X - none, C - relay NO/NC, D - SSR, E - open collector NPN (4), J - for external SSR, M - isolated MOS gate

#1

Increased front protection

X - none, P - IP65 front protection (5)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(3)


timers and counters Universal Programmable Counter CT34 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

Available as totalizer, R.P.M. meter, and combined One or two 6-digit LED displays Pulse- and analog-input versions Programmable divider and multiplier Pulse counting and batch counting Additional inputs CLEAR, GATE, and DIRECTION 6 user-selectable operating modes plus dosing mode Up to 2 programmable relay outputs Optional optical input isolation up to 1500 VAC RS485 serial interface available

CT34 is a sophisticated new-generation counter equipped with a 6-digit display, which can hold up to 999999 count units or batches, and may have up to 2 programmable relay outputs and an analog output for alarm signaling or process controlling. СТ34 is available as a counter, as an R.P.M. meter, and as a combination of both. As a counter, this model allows programming of 7 different counting and output-relay-action modes (including dosing mode) as well as counting pulses or pulse batches. The R.P.M.-meter variant has 6 operating modes. Besides its counting input, CT34 has 3 additional inputs – CLEAR, GATE, and DIRECTION – and a user-programmable software input filter. Other useful features include fraction number coefficient prescaler and programmable actual and displayed counting directions. With its various features and flexible programmable internal structure, the CT34 counter is a widely applicable device.

Technical specifications Counting input: - pulse, w/ programmable active front - analog, programmable (1,2) Input CLEAR Input GATE Input DIRECTION (3) Maximum input frequency Input filter Prescaler coefficients Input isolation (option)

Indication and controls mechanical contact (NO) or electronic (from PNP / NPN sensor) 0(4)...20 mA or 0...5(10) V resets counter to '0' (4 functions) enables pulse counting changes counting direction 5 kHz for suppression of contact bouncing 1...9999, multiplying and dividing optical, 1500 VAC

Modes Operating modes Counting modes Counting range Programming

Outputs Relay electromechanical (5) Solid state relay MOS gate Transistor gate (6) Output for external SSR Relay action Output pulse duration (8) Analog output Serial interface (1)

7 (incl. dosing mode) pulse counting and batch counting 0...2147483647 through keyboard (up to 2 outputs) 5A/250V w/ NO/NC (4) contact 1A/250VAC 0.1A/60V, optically isolated open collector, 40mA/40V 5…24 V, 30 mA according to the mode (7) 0.1...99.9 s, programmable 0(4)…20 mA or 0…10 V, isolated RS485, isolated

PV display (1) SP display LEDs Keyboard

6 LED indicators, 9 mm 6 LED indicators, 9 mm 2 LEDs for output state 4 membrane keys

Power supply Mains supply voltage (1) SMPS voltage Isolated low voltage Non-isolated low voltage Consumption

230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC (5) or 24 VAC (1) 12…24 VAC/DC max. 6 VA

Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity

Design and materials Dimensions [mm] Mounting Panel cutout [mm] Mounting depth [mm] Maximum weight [g] Protection, front/terminals Increased front IP (option) Case material Wiring (terminals)

'L'

-10...65 °C 0...85 %RH -20...65 °C 0...95 %RH, non-condensing 'S' 'H'

76x35x62 panel 71x29 56 180 IP54/20 IP65 plastic screw

48x48x110 panel 45x45 100 200 IP54/20 plastic screw

96x48x107 panel 90x42 98 280 IP54/20 IP65 plastic plug-in

(1)

Not available for case 'L' Available ONLY for variant 'CR'! Only with pulse input type! (4) NO for case 'L' (5) Ask for availability! (6) ONLY with isolated power supply! (7) st nd In case of variant 'CR' with pulse input, if not additionally specified, 1 relay is linked to counter and 2 – to R.P.M. meter. st nd With analog input, 1 relay is firmly linked to counter and 2 relay is user programmable. (8) nd Instead of 2 relay (_G5)! (9) Not available for case 'S' (2)

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org

COMECO reserves the right of changing specifications without prior notice!

Inputs


timers and counters Ordering code

CT34 - G0.G1.G3.G5G5.G9'9".G11 - #1.#2

Code Feature or option

Code values

Variant

C - totalizing counter, R - R.P.M. meter, CR - combined

G0

Case (front size)

H - 96x48 mm, S - 48x48 mm, L - 72x36 mm

G1

Power supply

A - 230 VAC , B - 115 VAC , C - 90…250 V, (5) (1) P - 12…24 V, non-isolated, Q - 12…24 V, isolated , R - 24 VAC

G3

Counting input

P - pulse, A - analog

G5

Relay output

G9' G9"

(1)

(1)

(1,2)

, D - SSR

(5)

Serial interface

X - none, B - RS485

Protocol

A - ASCII, C - ASCII for " PolyMonitor"

(5)

(7)

(8)

X - none, C - relay NO/NC M - isolated MOS gate

(4)

, E - open collector NPN

(6)

, J - for external SSR,

(1)

Analog output

X - none, E - 0…20 mA, F - 4…20 mA, K - 0…10 V

#1

Input isolation

X - none, I - input isolation

#2

Increased front protection

X - none, P - IP65 front protection (9)

COMECO reserves the right of changing specifications without prior notice!

G11

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org


timers and counters 2-channel Flow-rate Counter CT34SB ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

Accepts pulse signals from 2 flow-meters Fully-programmable math block Two 6-digit LED displays Indicates current flows, math result, total counts Programmable relay output Sensor supply voltage 5...24 VDC Programmable input filtering 96x48 front size panel mounting

CT34SB is a specialized 2-channel fully programmable flow-rate totalizing counter. The instrument is especially designed to measure pulse signals from 2 different flow-meters according to the functional block-diagram below:

Counter software allows a convenient programmable scaling of both measured flow signals and applying various calculations on both flow rates. CT34SB is equipped with two 6-digit LED displays indicating current flow-rates, mathematically calculated values as well as accumulated total counts. The counter has also an optional relay output for generating impulse when certain total value is reached (dosing function).

Technical specifications Power supply

Counting inputs Input type Active front Maximum input frequency Input filter Scaling coefficients Totalizer range Math functions

2 pulse inputs (A and B) contact (NO) or PNP/NPN sensor programmable 5 kHz programmable low-pass filter scale factor and time-base up to 5000000 counts A-B, A+B, A*B, A/B, A/(A+B)

Indication and controls Digital displays Display function (link) LEDs Keyboard

2 x 6 LED indicators, 9 mm Rate A(B), Math result, Total 2 LEDs for output state 3 membrane keys

Output Relay electromechanical Solid state relay (1) MOS gate Transistor gate (2) Output for external SSR Relay action Output pulse duration (1) (2)

5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated open collector, 40mA/40V 5…24 V, 30 mA totalizer set-point (dosing function) 0.02...1.2 s, programmable

Mains supply voltage SMPS voltage Isolated low voltage Non-isolated low voltage Consumption

230 VAC or 115 VAC 90…250 VAC/DC 12…24 VAC/DC or 24 VAC 12…24 VAC/DC max. 6 VA

Operating conditions Operating temperature Operating humidity Storage temperature Storage humidity

-10...65 °C 0...85 %RH -20...65 °C 0...95 %RH, non-condensing

Design and materials Dimensions Mounting Mounting depth Maximum weight Protection, front/terminals Increased front IP (option) Case material Wiring

96x48x107 mm panel cutout 90x42 mm 98 mm 280 g IP54/20 IP65 plastic plug-in terminals

Ask for availability! ONLY with isolated power supply!

Ordering code

CT34SB - G1.G5 - #1

Code Feature or option

Code values

G1

Power supply

A - 230 VAC, B - 115 VAC, C - 90…250 V, P - 12…24 V, non-isolated, Q - 12…24 V, isolated, R - 24 VAC

G5

Relay output

X - none, C - relay NO/NC, D - SSR (1), E - open collector NPN (2), J - for external SSR, M - isolated MOS gate

#1

Increased front protection

X - none, P - IP65 front protection

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org

COMECO reserves the right of changing specifications without prior notice!

Inputs


timers and counters Programmable Counter CT38 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

Low cost 4-digit LED display for up to 9999 units Easy programming Universal optically isolated counting input Additional RESET input available 6 modes of operation of the counter and the relay output Programmable input multiplying coefficient 48x48 mm DIN-sized front panel

CT38 is a single-channel programmable counter with simplified programming. The device has a 4-digit display and can count up to 9999 input pulses. CT38 may work as up or down counter and has a relay output for switching on and off electrical actuators. Relay output action at reaching the preset counter value is user programmable. CT38 offers 4 counting modes and 2 output action modes. It features optical input isolation, and, optionally, an additional RESET input. The universal input allows connection of both mechanical contacts and electronic sensors. A software preliminary multiplying coefficient enables counting several units at each pulse. With its compact size, easy programming, and attractive price, the CT38 counter is widely used in machine manufacturing and various other areas.

Technical specifications Inputs

Indication and controls

Counting input - type selection Input RESET Maximum input frequency Input filter (fixed) Prescaling multiplying coefficient Input isolation

mechanical contact (NO) or electronic (from PNP / NPN sensor) not needed (automatic) NO contact; resets counter to 0 500 Hz for input contact bouncing 1...999, programmable optical, 750 VAC

Modes

Digital display LEDs Keyboard

4 LED indicators, 10 mm 3 LEDs for output and modes 6 membrane keys

Power supply Mains supply voltage Isolated low voltage Non-isolated low voltage Consumption

230 VAC or 115 VAC 12 VDC 12 VDC or 12 VAC max. 2 VA

Operating conditions 4 (1) 2 (2) 0...9999 through keyboard (up to 2 relay outputs)

Counting modes Output action modes Counting range Programming

Outputs Relay electromechanical Solid state relay (3) MOS gate Transistor gate (4) Output for external SSR Relay action Output pulse duration

5A/250V w/ NO/NC contact 1A/250VAC 0.1A/60V, optically isolated open collector, 40mA/40V 12 V, 30 mA according to the mode 0.1...9.9 s, programmable

Operating temperature Operating humidity Storage temperature Storage humidity

-10...65 °C 0...85 %RH -20...65 °C 0...95 %RH, non-condensing

Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals

plastic in 45x45 mm panel cut-out or on 35 mm DIN rail socket (5) OCTAL or UNDECAL (6) 48x48(front)x92 mm max. 103 mm (w/ socket) max. 250 g IP40 / IP20

(1)

Counting up or down; counting with or without automatic reset at reaching preset counter value Output activates and retains the new state with counter reaching preset value; output activates for a short time with counter reaching preset value Ask for availability! (4) ONLY with isolated power supply! (5) Ordered separately (see 'Accessories') (6) ONLY with RESET input (G7="A") (2)

Ordering code

CT38 - G1.G5.G7

Code Feature or option

Code values

G1

Power supply

A - 230 VAC, B - 115 VAC, D - 12 VDC, E - 12 VAC, Q - 12 VDC, isolated

G5

Relay output

C - relay NO/NC, D - SSR (3), E - open collector NPN (4), J - for external SSR, M - isolated MOS gate

G7

RESET input

X - none, A - contact

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(3)


timers and counters Battery-powered Counter CT36 ♦ ♦ ♦ ♦ ♦ ♦

Low cost 8-digit totalizing LCD display 7-year lifetime without battery replacement 1 to 1000 cps selectable counting speed Front and rear-panel RESET 48x24 mm DIN-sized front panel

CT36 is a simple and low-cost battery-powered electronic counter, enclosed in a small plastic box with 48x24 mm front size. Equipped with a 8-digit LCD display, CT36 can count up to 99999999 units. It has 2 inputs counting input with counting speed up to 1000 cps and a RESET input. Both inputs can accept input signals from mechanical or electronic switches. A RESET button on the front panel is also available. The device may be equipped with micros-witches allowing front frequency selection as well as front reset key enabling. CT36 is powered by an incorporated lithium battery that has approximately 7 years of life cycle. Thanks to its small size and longlife battery operation, CT36 can be very useful for many applications requiring independent supply and small mounting dimensions such as integration in water meters, gas meters, etc.

Technical specifications Power supply

Inputs Counting input - active front - residual voltage Input RESET - function - reset pulse Maximum input frequency ON-sense OFF-sense

mechanical contact (NO) or electronic (NPN/PNP/MOS-gate sensor) rising ≤ 0.5 VDC NO contact or electronic sensor resets counter to 0 min. 20 ms 1 Hz, 30 Hz, 1000 Hz, fixed or selectable < 10 kΩ > 750 kΩ

Mode

Indication and controls 8 LCD indicators, 9 mm RESET left: select input frequency, right: front reset enable/disable

Digital display Front push button Side micro-switches

Ordering code

Operating conditions Ambient temperature Ambient humidity Storage temperature Vibration (malfunction) Shock (malfunction) Dielectric strength Insulation resistance

-10...55 °C, non-freezing 35...85 %RH -25...65 °C, non-freezing 0.3 mm at 10…55 Hz for 10 min 3 x 100 m/s2 (≈ 10 G) 2000 VAC for 1 min > 100 MΩ at 500 VDC

Case material Mounting Wiring Dimensions Mounting depth Weight Protection class

plastic in 45x22 mm panel cut-out screw terminals 48x24(front)x58 mm 54 mm max. 60 g IP20

CT36 - G4

Code Feature or option

Code values

Variant

U - w/ selectable input frequency, A - w/ 1 Hz input, B - w/ 30 Hz input, C - w/ 1 kHz input

Reset

D - from input RESET, C - from front-panel button, DC - from both sources

COMECO reserves the right of changing specifications without prior notice!

G4

3 V from lithium battery CR2477 ≈ 7 years (at 20 °C)

Design and materials up counting 0...99999999

Counting mode Counting range

Supply voltage Battery life

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


handheld devices 2-channel Programmable Thermometer H5700 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

Good accuracy at low consumption Operates with Pt1000 and 3 types of thermocouples Universal input available Measures temperature from up to 2 sensors 4-digit LCD display with mode indication Programmable auto power-off function Battery voltage management Readings in Celsius or Fahrenheit Sensor failure control

H5700 is a handheld 2-channel microprocessor-based device for measurement of temperature in 1 or 2 points by the means of Pt1000 sensors or thermocouples type "J", "K", or "S". The device has a 4-digit display providing a resolution of 0.1 °C within the -99.9...999.9 °C range. Two modes of operation – measurement of 1 temperature and measurement of 2 temperatures and temperature difference – are available. H5700 is programmed and controlled through a folio-type keyboard providing high degree of environmental protection. The device is offered with 2 alkaline or rechargeable 1.5 V AA batteries and features a special automatic-battery-control function. The numerous features of H5700, its high accuracy, and low consumption make it a widely applicable measurement instrument.

Technical specifications Inputs

(up to 2 inputs) -100.0...660.0 °C -100.0...1200 (999.9) °C -100.0...1300 (999.9) °C 0.0...1700 (999.9) °C

Pt1000 (w=1.385) Thermocouple "J" Thermocouple "K" Thermocouple "S"

Indication and controls 4-digit LCD, 13 mm 3 membrane keys

Digital display Keyboard

Accuracy

Power supply Supply voltage Operating consumption Stand-by consumption Auto-power-off time

3 V from 2 batteries AA 1.5 V (1) less than 3 mA less than 5 µA 0...30 min, programmable

0.1% (0.3% for T/C input) from span negligible ± 1 °C 0.01% from span for 1 °C 0.05% from span for 1 V

Case material Probe connection Dimensions Weight Protection, case/socket

plastic 4-pin snap-in connector ø8, type 'C3' 65x118x22 mm max. 110 g (w/ batteries) IP44 / IP20

H5700 - G1.G6'6"G6'6"

Code Feature or option

Code values

G1

Power supply

X - none (2), G - long-life batteries, H - rechargeable batteries

G6'6"

Input

X - none (3), A - programmable, BG - Pt1000, CJ - thermocouple "J", CK - thermocouple "K", CS - thermocouple "S"

The device is supplied without batteries. Only the second input can be cancelled.

COMECO reserves the right of changing specifications without prior notice!

(3)

-10...65 °C 0...85 %RH

Battery charger can be ordered separately (see 'Accessories').

Ordering code

(2)

Operating temperature Operating humidity

Design and materials

Measurement error Non-linearity Cold junction compensation Temperature drift Supply-voltage variation influence (1)

Operating conditions

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


handheld devices Programmable Hygro-/Thermometer H5800 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

Good accuracy at low consumption Operates with COMECO humidity handheld probes Humidity and temperature measurement Automatic temperature compensation of the RH probe 4-digit LCD display with mode indication Programmable auto power-off function Battery voltage management Readings in percentage, degrees Celsius or Fahrenheit

H5800 is a handheld microprocessor-based device for relative-humidity measurement in air and non-aggressive gases, designed to operate with COMECO’s RH probes. With the help of a Pt1000 sensor build in the RH probe, H5800 compensates probe temperature drift and indicates medium temperature. The device is equipped with a 4-digit display providing a resolution of 0.1. Two modes of operation – measurement of relative humidity and measurement of medium temperature in degrees Celsius or Fahrenheit – are available. Dew-point, absolute humidity, mixing ratio, and enthalpy can also be measured through calculation. H5800 is programmed and controlled through a folio-type keyboard providing high degree of environmental protection. The device is offered with 2 alkaline or rechargeable 1.5 V AA batteries and features a special automatic-battery-control function. The numerous features of H5800, along with its high accuracy and low consumption, make it a widely applicable measurement instrument.

Technical specifications Inputs

Operating conditions

RH input - range Temperature input - range

0…100 mV 0…100 %RH Pt1000 (w=1.385) -20...150 °C (-4...302 °F)

Indication and controls 4-digit LCD, 13 mm 3 membrane keys

Digital display Keyboard

Accuracy

Power supply Supply voltage Operating consumption Stand-by consumption Auto-power-off time

3 V from 2 batteries AA 1.5 V (1) less than 8 mA less than 1 µA 0...30 min, programmable

0.1% from span 0.1% from span negligible 0.01% from span for 1 °C 0.2% from span for 1 V 0.1% from span for 1 V

Case material Probe connection Dimensions Weight Protection, case/socket

plastic 4-pin snap-in connector ø8, type 'C3' 65x118x22 mm max. 110 g (w/ batteries) IP44 / IP40

Battery charger can be ordered separately (see 'Accessories').

Ordering code

H5800 - G1

Code Feature or option G1

Power supply

Code values X - none (2), G - long-life batteries, H - rechargeable batteries

The device is supplied without batteries.

COMECO reserves the right of changing specifications without prior notice!

(2)

-10...65 °C 0...85 %RH

Design and materials

RH measurement error Temperature measurement error Non-linearity Temperature drift Supply-voltage influence for RH Supply-voltage influence for T (1)

Operating temperature Operating humidity

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


handheld devices Hygro-/Thermometer for Solids H5850 ♦ ♦ ♦ ♦ ♦ ♦ ♦

Good accuracy at low consumption Operates with RHP humidity probes Moisture and temperature measurement 4-digit LCD display with mode indication Programmable auto power-off function Battery voltage management Readings in percentage, degrees Celsius or Fahrenheit

H5850 is a handheld microprocessor-based device for humidity measurement of solids and bulk materials, designed to operate with COMECO’s RH probe model RHP. With the help of a Pt1000 sensor build in the RH probe, H5850 indicates the medium temperature too. The device is equipped with a 4-digit display providing a resolution of 0.1. Three modes of operation – measurement of moisture content, measurement of relative humidity, and measurement of medium temperature in degrees Celsius or Fahrenheit – are available. H5850 can be programmed and controlled through a folio-type keyboard providing high degree of environmental protection. The device is offered with 2 alkaline or rechargeable 1.5 V AA batteries and features a special automatic-batterycontrol function. The numerous features of H5850, along with its high accuracy and low consumption, make it a useful instrument for bulk-material moisture measurement.

Technical specifications Inputs

Operating conditions

Humidity input - moisture-content range - relative-humidity range Temperature input - range

from RHP probe 0…300 % 0…75 % Pt1000 (w=1.385) -20...150 °C (-4...302 °F)

Indication and controls 4-digit LCD, 13 mm 3 membrane keys

Digital display Keyboard

Accuracy

Power supply Supply voltage Operating consumption Stand-by consumption Auto-power-off time

3 V from 2 batteries AA 1.5 V (1) less than 8 mA less than 1 µA 0...30 min, programmable

0.2% from span 0.1% from span negligible 0.01% from span for 1 °C 0.2% from span for 1 V 0.1% from span for 1 V

Case material Probe connection Dimensions Weight Protection, case/socket

plastic 4-pin snap-in connector ø8, type 'C3' 65x118x22 mm max. 110 g (w/ batteries) IP44 / IP20

Battery charger can be ordered separately (see 'Accessories').

Ordering code

H5850 - G1

Code Feature or option G1

Power supply

Code values X - none (2), G - long-life batteries, H - rechargeable batteries

The device is supplied without batteries.

COMECO reserves the right of changing specifications without prior notice!

(2)

-10...65 °C 0...85 %RH

Design and materials

Humidity measurement error Temperature measurement error Non-linearity Temperature drift Supply-voltage influence for humidity Supply-voltage influence for T (1)

Operating temperature Operating humidity

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


handheld devices Handheld Moisture-content Meter H6300 ♦ ♦ ♦ ♦ ♦ ♦ ♦

Non-contact measurement of wood and concrete samples Modern electromagnetic measurement principle Measurement depth 1...7 cm Entirely eliminates temperature influence Integral moisture-content value measurement Very fast measurement Low price

H6300 by COMECO is designed to measure moisture content of wood or concrete samples, employing an electromagnetic measurement principle. With the help of a sensor detecting variations of electromagnetic field within sample, the device measures moisture content even without an electrical contact with the sample. To perform a measurement, simply place the moisture detector on even sample surface. MOISTURE DETECTOR

A correction table for measurement correction for various types of wood and concrete is supplied with the moisture meter. H6300 may be used for other similar materials if their specific weight when completely dry is known. The moisture detector is equipped with a 16-dot LED display for exact reading of moisture in 1% steps. H6300 is offered with an alkaline or rechargeable 9 V battery. Battery charger is available as accessory. An exceptionally lightweight and compact device, H6300 is especially suited for measurement of thin samples as well as for fast and frequent measurements.

Technical specifications Input

Indication and controls

Input type Measurement range Temperature range Sample material type Temperature influence Surface-moisture interference Static-charge interference

electromagnetic 4...22% moisture content -20...100 °C up to 100 different types none insignificant insignificant

Accuracy ± 1% 0.05% from span for 1 °C 0.05% from span for 1 V fixed manual, via correction table

Material Dimensions Weight Protection class

Operating temperature Operating humidity

Battery charger can be ordered separately (see 'Accessories').

H6300 - G1

Code Feature or option G1 (3)

Supply voltage Consumption Battery state control

9 V from battery 6F22 (1) less than 3 mA automatic

plastic 65x112x22 mm max. 120 g IP44

Operating conditions 2 x 7 cm 13 mm 1s

Minimum sample area Minimum sample thickness Measurement time

(2)

Power supply

Code values

Variant

W - for wood, C - for concrete (2)

Power supply

X - none (3), G - long-life battery, H - rechargeable battery

Ask for availability! The device is supplied without battery.

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

-10...65 °C 0...85 %RH

COMECO reserves the right of changing specifications without prior notice!

Measurement requirements

Ordering code

16 LED dots 1 membrane key

Design and materials

Measurement error Temperature drift Supply-voltage variation influence Factory calibration Correction for other material

(1)

Bargraph display Keyboard




actuators and heaters Low-cost 1-phase AC Relay SSRP ♦ ♦ ♦ ♦ ♦ ♦

Zero-cross output switching Up to 275 VAC operating voltage 10 A, 16 A, 25 A, or 40 A switching RMS current 4 input ranges 4000 V input / output insulation Heatsinks available

The SSRP solid state relay is a zero-cross operating electronic module designed to switch single-phase AC power loads. Thanks to its higher switching frequency and practically complete absence of electromagnetic interference, the SSR module is a non-contact and convenient substitute of power contact relays. The life and reliability of the SSR module, compared to these of the contact relays, are much higher because there are no moving parts, noise, shocks, and vibration during the operation. SSRP can switch active or small inductive loads from 10 to 40 A at power voltage up to 275 VAC. The control input is optically isolated from the output and accepts AC or DC voltage signals. An operating LED indicates ON/OFF device status. Heatsinks are available as accessory.

Technical specifications Input

General specifications

Control voltage Input current Turn-on / off voltage Reverse voltage protection

Output

(no connection with the input types!)

On-state current at proper heatsink (1) ≤ 10 Arms ≤ 16 Arms ≤ 25 Arms ≤ 40 Arms Minimum holding current 50 mA 80 mA 50 mA 80 mA Non-rep. surge current at t = 20 ms 160 A 400 A 100 A 250 A Maximum leakage current 2 mA 5 mA 1 mA 3 mA Critical rate of current rise dI/dt 50 A/μs 50 A/μs 50 A/μs 50 A/μs I2t value for fusing at t = 10 ms 78 A2s 78 A2s 78 A2s 78 A2s On-state voltage at rated current 1.6 Vrms 1.6 Vrms 1.6 Vrms 1.6 Vrms Critical off-state voltage rise dV/dt 400 V/μs 400 V/μs 500 V/μs 500 V/μs Operational frequency 45...65 Hz 45...65 Hz 45...65 Hz 45...65 Hz Thermal resistance (junction-case) 2.3 °C/W 2.1 °C/W 1.1 °C/W 1.2 °C/W (1) (2)

min. 24...max. 275 VACrms 600 Vp 700 Vp > 0.6 -20...65 °C -40...85 °C glass-filled plastic aluminum 4000 VACrms 2500 VACrms IP00 4 x M4 screws 2 x M4 screws MAC2 rail clamp (2) ø3, red ≈ 100 g

Operating AC voltage Rep. off-state peak voltage Non-rep. off-state peak voltage Power factor Operating temperature Storage temperature Case material Base plate (heatsink) material Input / output insulation Output / case insulation Protection class Wiring Mounting Rail mounting ON-indicating LED Weight

4...36 VDC 6...26 VAC/DC 115 VAC 230 VAC 6...12 mA 12 mA 5...12 mA 6 mA 3 VDC 4 VAC / 5 VDC 90 VAC 180 VAC -32 VDC -32 VDC -

We highly recommend using SSR at no more than 80% of maximum on-state current! Ordered separately (see 'Accessories') 22

30 12 FUSE

1

+

LOAD

2

4.3

24

80

48

Heatsink specifications Heatsink surface [cm2] / length [mm] (at 85 °C heatsink temperature) SSRP variant Current Æ Ambient temperature È

10

16

10 A

25

10 A

16 A

15 A

20 A

40 25 A

20 A

40 A

20 °C

72 / 62

60 / 62

214 / 62

134 / 62

287 / 62

499 / 62

237 / 62

607 / 62

1280 / 120

40 °C

150 / 62

124 / 62

445 / 62

278 / 62

601 / 62

1041 / 100

494 / 62

1275 / 120

2668 / 250

60 °C

485 / 62

400 / 62

1435 / 135

907 / 85

1924 / 180

Ordering code

1600 / 150

SSRP - G1

Code Feature or option

Code values

Variant

10, 16, 25, 40

G1

Input

A - 230 VAC, B - 115 VAC, D - 4…36 VDC, Е - 6…26 VAC/DC

Applicable accessories Code Description HS__

30 A

Heatsink (specify the length [mm] using the table above) w/ or w/o rail-mounting clamp (2)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

3

80

AC VOLTAGE

61

CONTROL VOLTAGE

47

34

4

68 56


actuators and heaters 1-phase AC Relay for Inductive Loads SSRQ ♦ ♦ ♦ ♦ ♦ ♦

Designed for all types of loads up to 400 VAC Zero-cross output switching 10 A or 16 A switching RMS current 4 input ranges 4000 V input/output insulation Heatsinks available

The SSRQ solid state relay is a zero-cross operating electronic module designed to switch single-phase AC power loads. Since there are no moving parts, noise, shocks, and vibration during the operation, the life and reliability of the SSR module, compared to these of the contact relays, are much higher. Thanks to a snubberless™ triac, SSRQ can switch both active and inductive loads up to 16 A at power voltage up to 400 VAC. The control input is optically isolated from the output and accepts AC or DC voltage signals.

Technical specifications Input

General specifications

Control voltage Input current Turn-on/off voltage Reverse voltage protection

4...36 VDC 6...26 VAC/DC 115 VAC 230 VAC 6...12 mA 12 mA 5...12 mA 6 mA 3 VDC 4 VAC / 5 VDC 90 VAC 180 VAC -32 VDC -32 VDC (no connection with the input types!)

Output On-state current at proper heatsink (1) Minimum holding current Non-rep. surge current at t = 20 ms Maximum leakage current Critical rate of current rise dI/dt I2t value for fusing at t = 10 ms On-state voltage at rated current Critical off-state voltage rise dV/dt Operational frequency Thermal resistance (junction-case) (1) (2)

≤ 16 Arms 50 mA 160 A 2 mA 50 A/μs 78 A2s 1.6 Vrms 400 V/μs 45...65 Hz 2.1 °C/W

≤ 10 Arms 50 mA 100 A 1 mA 50 A/μs 78 A2s 1.6 Vrms 400 V/μs 45...65 Hz 2.3 °C/W

400 VACrms 24 VACrms 800 Vp 900 Vp -20...65 °C -40...85 °C glass-filled plastic aluminum 4000 VACrms 2500 VACrms IP00 4 x M4 screws 2 x M4 screws MAC2 rail clamp (2) ø3, red ≈ 100 g

Maximum operating AC voltage Minimum operating AC voltage Rep. off-state peak voltage Non-rep. off-state peak voltage Ambient temperature Storage temperature Case material Base plate (heatsink) material Input/output insulation Output/case insulation Protection class Wiring Mounting Rail mounting ON-indicating LED Weight

We highly recommend using SSR at no more than 80% of maximum on-state current! Ordered separately (see 'Accessories') 22

30 12 1

FUSE

+ 3

2

80

AC VOLTAGE

47

CONTROL VOLTAGE

61

34

4

68 56

LOAD

4.3

24

80

48

SSRQ variant

10

Current Æ Ambient temperature È

10 A

16 10 A

20 °C

72 / 62

60 / 62

214 / 62

40 °C

150 / 62

124 / 62

445 / 62

485 / 62

400 / 62

1435 / 135

60 °C

Ordering code

SSRQ - G1

Code Feature or option

Code values

Variant

10, 16

G1

Input

A - 230 VAC, B - 115 VAC, D - 4…36 VDC, Е - 6…26 VAC/DC

Applicable accessories Code Description HS__

16 A

Heatsink (specify the length [mm] using the table above) w/ or w/o rail-mounting clamp (2)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Heatsink specifications Heatsink surface [cm2] / length [mm] (at 85 °C heatsink temperature)


actuators and heaters Low-cost DC Relay SSRD ♦ ♦ ♦ ♦ ♦ ♦

For DC loads Up to 300 VDC operating voltage Up to 40 A switching DC current 4 input ranges 4000 V input/output insulation Heatsinks available

The SSRD solid state relay is an electronic module designed to switch active or active/inductive DC power loads from 5 to 40 A at power voltage up to 300 VDC. Thanks to its higher switching frequency and practically complete absence of electromagnetic interference, the SSR module is a non-contact and convenient substitute of power contact relays. The life and reliability of the SSR module, compared to these of the contact relays, are much higher because there are no moving parts, noise, shocks, and vibration during the operation. The control input is optically isolated from the output and accepts AC or DC voltage signals. An operating LED indicates ON/OFF device status. Heatsinks are available as accessory.

Technical specifications Input

General specifications

Control voltage Input current Turn-on / off voltage Reverse voltage protection

4...36 VDC 6...26 VAC/DC 115 VAC 230 VAC 6...12 mA 12 mA 5...12 mA 6 mA 3 VDC 4 VAC / 5 VDC 90 VAC 180 VAC -32 VDC -32 VDC -

Output Operating DC voltage On-state current at proper heatsink (1) Non-repetitive pulse current Maximum leakage current On-state voltage at rated current Critical off-state voltage rise dV/dt Thermal resistance (junction-case) Power factor (1) (2)

-20...65 °C -40...85 °C glass-filled plastic aluminum 4000 VACrms 2500 VACrms IP00 4 x M4 screws 2 x M4 screws MAC2 rail clamp (2) ø3, red ≈ 100 g

Operating temperature Storage temperature Case material Base plate (heatsink) material Input / output insulation Output / case insulation Protection class Wiring Mounting Rail mounting ON-indicating LED Weight

(no connection with the input types!) 3...40 VDC 15...60 VDC 15...300 VDC ≤5A ≤ 20 A ≤ 40 A ≤ 15 A ≤ 130 A ≤ 160 A 10 μA 100 μA 100 μA 0.5 V 2V 1.3 V 400 V/μs 7 V/ns 15 V/ns 2.7 °C/W 1.6 °C/W 0.5 °C/W > 0.6 > 0.6 > 0.7

We highly recommend using SSR at no more than 80% of maximum on-state current! Ordered separately (see 'Accessories') 22

68 56

80

47

61

34

30 12

4.3

24

80

48

SSRD variant Current Æ

1

2

5A

20 A

30 A

20 °C

62

62

40 °C

62

62

60 °C

62

62

Ambient temperature È

Ordering code

3 40 A

10 A

16 A

62

62

62

62

62

62

120

62

62

120

120

250

62

120

250

SSRD - G1

Code Feature or option

Code values

Variant

1, 2, 3

G1

Input

A - 230 VAC, B - 115 VAC, D - 4…36 VDC, Е - 6…26 VAC/DC

Applicable accessories Code Description HS__

Heatsink (specify the length [mm] using the table above) w/ or w/o rail-mounting clamp (2)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

20 A

COMECO reserves the right of changing specifications without prior notice!

Heatsink specifications Heatsink length [mm] (at 85 °C heatsink temperature)


actuators and heaters 1-phase Power AC Relay SSRT ♦ ♦ ♦ ♦ ♦ ♦

Zero-cross output operation Double thyristor output switch Up to 400 VAC operating voltage Up to 200 A switching RMS current 4 input ranges 4000 V input/output insulation

The SSRT solid state relay is a zero-cross operating electronic module designed to switch single-phase AC power loads. Thanks to its higher switching frequency and practically complete absence of electromagnetic interference, the SSR module is a non-contact and convenient substitute of power contact relays. The life and reliability of the SSR module, compared to these of the contact relays, are much higher because there are no moving parts, noise, shocks, and vibration during the operation. The SSRT electronic relays can switch active loads up to 200 Arms and inductive loads up to 95 Arms at power voltage up to 400 VAC. The control input is optically isolated from the output and accepts AC or DC voltage signals. An operating LED indicates ON/OFF device status.

Technical specifications Input

General specifications

Control voltage Input current Turn-on/off voltage Reverse voltage protection

4...36 VDC 6...26 VAC/DC 115 VAC 230 VAC 6...12 mA 12 mA 5...12 mA 6 mA 3 VDC 4 VAC / 5 VDC 90 VAC 180 VAC -32 VDC -32 VDC -

Output ≤ 200 Arms

AC switching current at proper heatsink (1) Minimum holding current Non-rep. surge current at t = 10 ms Maximum leakage current Critical rate of current rise dI/dt I2t value for fusing at t = 10 ms On-state voltage at rated current Critical off-state voltage rise dV/dt Operational frequency Thermal resistance (junction-case) (1) (2)

200 mA 1700 A 15 mA 150 A/μs 1125 A2s 1.6 Vrms 500 V/μs 45...65 Hz 0.14 °C/W

min. 24...max. 400 VACrms 1200 Vp 1300 Vp > 0.5 -20...65 °C -40...85 °C aluminum, 150 mm long 4000 VACrms 2500 VACrms IP00 screw terminals 3 x M5 screws for optimized cooling MAC2 rail clamp (2) ø3, red max. 350 g (w/ standard heatsink)

Operating AC voltage Rep. off-state peak voltage Non-rep. off-state peak voltage Power factor Operating temperature Storage temperature Standard heatsink Input/output insulation Output/case insulation Protection class Input wiring Output wiring Mounting Rail mounting ON-indicating LED Weight

We highly recommend using SSR at no more than 80% of maximum on-state current! Ordered separately (see 'Accessories')

FUSE 3

2

1

AC VOLTAGE

+ 4

LOAD

5

Heatsink specifications Heatsink surface [cm2] / length [mm] (at 105 °C heatsink temperature) Max. RMS current Æ Ambient temperature È 20 °C

(3)

40 A

60 A

80 A

100 A

430 / 150

1300 / 150

1900 / 180

3800 / 350

40 °C

720 / 150

2100 / 200

3300 / 310

60 °C

1500 / 150

4400 / 410

6900 / (3)

6500 /

120 A

(3)

13500 / (3)

Requires additional forced (fan) cooling!

Ordering code

SSRT - G1

Code Feature or option G1

Input

Code values A - 230 VAC, B - 115 VAC, D - 4…36 VDC, Е - 6…26 VAC/DC

Applicable accessories Code Description HS__

Heatsink (specify the length [mm] using the table above) w/ or w/o rail-mounting clamp (2)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

5800 / (3) 10000 / (3) 20400 / (3)

COMECO reserves the right of changing specifications without prior notice!

CONTROL VOLTAGE


other control instrumentation Switch-mode Power Supply TC60P ♦ ♦ ♦ ♦

11-pin box for DIN-rail mounting Output power up to 5.5 W 90...250 VAC/DC SMPS Up to 2 independent stabilized output voltages

Technical specifications Input

Accuracy

Voltage Frequency Turn-on voltage Efficiency

90...250 V 47...440 Hz ≥ 85 VAC 76%, typical

Outputs

(up to 2 outputs) 1(2) x 24 VDC ≤ 0.23 A ≤ 5.5 W > 240 mV 4.0 kV 100 MΩ at 500 V

DC voltage Rated current Rated power AC voltage ripple Isolation voltage Isolation resistance

Protection 0.1 A 30 V ± 8% 105%

Front-panel fuse Over voltage Over load (1)

Operating conditions Operating temperature Operating humidity

-20...70 °C 0...85 %RH, non-condensing

Design and materials Case material Wiring Mounting Dimensions Weight Protection, front/terminals

plastic socket UNDECAL (1) in socket or on 35 mm DIN rail 35x78x91 mm max. 200 g IP44 / IP20

TC60P - G11G11

Code Feature or option G11

Output voltage (2)

Code values X - none (3), 24 - 24 VDC, Z - other (specify!)

Output supply voltages must be identical. At least one output must be ordered!

COMECO reserves the right of changing specifications without prior notice!

(3)

< ± 1.0% < ± 0.5% < ± 0.5% < 0.03% for 1 °C

Ordered separately (see Accessories)

Ordering code

(2)

Voltage tolerance Line regulation Load regulation Temperature drift

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


other control instrumentation Interface Adapter IA100 ♦ ♦ ♦ ♦ ♦

Universal RS485 to RS232 converter Designed for all COMECO devices equipped with RS485 Data acquisition from up to 32 net devices Suitable for COMECO "PolyMonitor" software Low cost

The IA100 interface adapter is a simple electronic device, designed to support the "PolyMonitor" multi-point data-acquisition software applicable for configuration and data collecting from a network of various COMECO control devices with RS485 interface and net addresses. IA100 supports up to 32 devices, connected into a RS485 net as well as the RS232 communication with PC or operating station. The information collected during the data-acquisition process can be stored, viewed, printed, and further processed through the "PolyMonitor" program or via customer-developed PC software based on the free communication protocols of the COMECO network devices.

Technical specifications 'Input' interface

Power supply

Interface type Function Supported net devices Format Baud rate

RS485 net control and data acquisition up to 32 8 (data) + 1 (stop), even parity max. 9600 bps

'Output' interface Interface type Function Format Baud rate

RS232 connection to PC 8 (data) + 1 (stop), none parity 9600 bps

Software "PolyMonitor" (1)

Data acquisition

Accessories custom made K6 (1)

RS485 input cable RS232 output cable

9 VAC/DC included max. 90 mA LED for power ON

Operating conditions Operating temperature Operating humidity

0...50 °C 0...80 %RH

Design and materials Case material Mounting RS232 connector RS485 connectors Dimensions Weight Protection, front/terminals

plastic desktop DB9, female RJ14, female and plug-in duplicating connector 72x150x31 mm max. 250 g IP54 / IP20

Ordered separately

Ordering code

IA100

COMECO reserves the right of changing specifications without prior notice!

(1)

Supply voltage Mains adapter (230 VAC) Consumption LEDs

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


other control instrumentation USB Interface Adapter IA250 ♦ ♦ ♦ ♦ ♦ ♦ ♦

Universal USB-to-Serial converter Optically isolated adapter Complies with USB 2.0 full speed standard Supports COMECO transmitters and RS485 devices Does not require additional power supply Suitable for "PolyMonitor" and "TraCon" software Small size and low cost

IA250 is a universal isolated interface adapter, designed to support interface connection between COMECO devices and PC or other USB devices. Its electronics is enclosed in a small-sized plastic box with IP54 front protection and equipped with USB-B and RJ25 interface connectors. Powered by the USB interface line, this plug-and-play device does not need any additional power supply. Two IA250 variants are available: - a variant for configuration and data collecting from a network of various COMECO control devices with RS485 interface and net addresses; - a variant for configuring COMECO transmitters via quasi-RS232 interface. IA250 is applicable to the "PolyMonitor" data-acquisition software and the transmitter-configuration program "TraCon", and may also be used with customer-developed PC software based on the free communication protocols of the COMECO devices.

Technical specifications 'Input' interface

Power supply

Network interface - supported net devices - function Transmitter interface - supported net devices - function Format Baud rate

RS485 up to 32 devices in up to 8 groups net control quasi RS232 COMECO smart transmitters configuration and data acquisition 8 (data) + 1 (stop), even parity max. 9600 bps

'Output' interface

5 VDC from USB line max. 100 mA

Indication 'Tx' LED 'Rx' LED

Accessories

(1)

Input cable Output cable

for data transmitting for data receiving variant 'N': K10U; variant 'T': K1U or K2U K8 (USB-B-to-USB-A standard)

Operating conditions

Interface type Function Format Speed Isolation

USB 2.0 full speed compatible connection to PC USB 2.0 specifications USB 2.0 specifications optical, 750 VAC

Software USB driver Transmitter configuration Data acquisition

FTDI standard USB driver "TraCon" v2.0 or higher, free "PolyMonitor" (1)

Operating temperature Operating humidity

0...50 °C 0...80 %RH

Design and materials Case material Mounting Input connector Output connector Dimensions Weight Protection class

plastic desktop RJ25, female USB-B, female 40x73x26 mm max. 60 g IP54

Ordered separately

Ordering code

IA250

Code Feature or option

Variant

Code values N - for RS485, T - for transmitters (quasi-RS232)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(1)

Supply voltage Consumption


other control instrumentation Interface Adapter / Datalogger IA300 InfoPrint ♦ ♦ ♦ ♦ ♦ ♦ ♦

RS485-to-RS232 converter Data acquisition from up to 32 net devices Thermal printer control for up to 8 process graphics Data-logging functions Easy configuration with "InfoPrint" software Convenient indication Attractive price-to-resources ratio

The IA300 interface adapter InfoPrint is an intelligent device designed especially to collect data from different COMECO instruments equipped with RS485 interface and net addresses. IA300 supports up to 32 devices, connected into a RS485 net and combined in 8 groups, thermal serial printer, and RS232 communication with PC. The information collected during the data-acquisition process can be used for: - printing up to 4 process charts on-line and up to 8 charts off-line; - data logging in the adapter memory and off-line downloading to PC for further processing. The IA300 electronics is equipped with 6 LED indicators (for power and communication modes) and convenient keyboard, all mounted in a plastic enclosure with IP54 front protection. All configuration procedures (including real-time clock) can be easily programmed with the "InfoPrint Command Interface" software. With its attractive price and enhanced capabilities, the IA300 interface adapter InfoPrint is a powerful solution for building multi-point monitoring systems.

Technical specifications 'Input' interface

Indication and controls

Interface type Function Supported net devices Format Baud rate

RS485 net control and data acquisition up to 32 8 (data) + 1 (stop), even parity 4800 bps

'Output' interface Interface type Function Format Baud rate

RS232 connection to PC or serial printer 8 (data) + 1 (stop), none parity 9600 bps

Data acquisition: - max. channels - max. device groups Graphics printing: - supported printer - max. graphics Data logging: - memory capacity - data downloading Configuration software

Operating conditions 0...50 °C 0...80 %RH

Operating temperature Operating humidity

Power supply up to 32 up to 8 serial thermal printer OT801 4 (on-line), 8 (off-line) 32 Kb to PC via RS232 "InfoPrint Command Interface", free

Accessories custom made K6 (1)

RS485 input cable RS232 output cable (1)

for power ON for communication to PC/printer OK for communication to PC/printer failed for RS485 stopped or memory full for data transmitting for data receiving 2 membrane keys

9 VAC/DC included max. 110 mA

Supply voltage Mains adapter (230 VAC) Consumption

Design and materials Case material Mounting RS232 connector RS485 connectors Dimensions Weight Protection, front/terminals

plastic desktop DB9, female RJ14, female and plug-in duplicating connector 72x150x31 mm max. 250 g IP54 / IP20

Ordered separately

Ordering code

IA300 - #1.#2

Code Feature or option

Code values

#1

Thermal printer

X - none, OT - thermal printer OT801 plus RS232 cable and 1 paper roll

#2

Additional paper rolls

X - none, 1…10 - number of additional paper rolls

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Functions and configuration

'On' LED 'RS 232 - Comm' LED 'Fail' LED 'Stop/Full' LED 'RS 484 - Tx' LED 'RS 484 - Rx' LED Keyboard


miscellaneous Software

Code

Software

Description

OS Devices Interface

Special Cable

Interface Adapter no

Notes

S1

"MiniSoft"

transmitter configuration and data-acquisition program

WIN MiniPAQ

RS232

yes

S2

"RStest"

simple program for RS232 or RS485 communication test

WIN all

RS232 RS485

depending on device connected

S3

"TraCon"

transmitter configuration and data-acquisition program

WIN TRB(I), TRY, RS232 TRZ, TRC

yes

no

free download from www.tracon.bz

S4

"Ipro"

transmitter configuration and data-acquisition program

WIN TRS (IPAQ)

RS232

yes

no

product of INOR

S5

"MePro"

HART Transmitter configuration and data-acquisition program

WIN MESO

HART

no

HART modem (communicator)

product of INOR

RS485

no

IA300

"InfoPrint"

configuration program for IA300 interface adapter / printer / datalogger

WIN IA300

S6 S7

"InfoMonitor"

data-acquisition program for TC800

WIN TC800

RS485

no

IA150

WIN LCSUPx (EchoTrack)

no

"EView"

viewing and configuration software for ultrasonic level transmitters w/ HART interface

HART

S8

HART modem (communicator)

S9

"PolyMonitor" program

universal data-acquisition

WIN all w/ RS485

RS485

no

IA100 IA250

S10

"UniConf"

universal configuration program

WIN all

RS232 RS485

S11

"Process"

single-process monitoring and recording program

WIN RT390

RS232

no

no

S12

"ThermLog"

temperature data-acquisition program for TC800

DOS TC800

RS485

no

IA150 (1)

S13

"ProfiSoft"

transmitter configuration and data-acquisition program

WIN TRP (ProfIPAQ)

RS232

yes

no

S14

"HartTemp"

HART Transmitter configuration and data-acquisition program

WIN TRH

HART

no

HART modem (communicator)

discontinued (1) product of NIVELCO

depending on device connected

product of Raycho Raykov product of INOR

Contact COMECO

COMECO reserves the right of changing specifications without prior notice!

(1)

product of INOR

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org


miscellaneous Software

Code

Software

Description

OS Devices Interface

Special Cable

Interface Adapter no

Notes

S1

"MiniSoft"

transmitter configuration and data-acquisition program

WIN MiniPAQ

RS232

yes

S2

"RStest"

simple program for RS232 or RS485 communication test

WIN all

RS232 RS485

depending on device connected

S3

"TraCon"

transmitter configuration and data-acquisition program

WIN TRB(I), TRY, RS232 TRZ, TRC

yes

no

free download from www.tracon.bz

S4

"Ipro"

transmitter configuration and data-acquisition program

WIN TRS (IPAQ)

RS232

yes

no

product of INOR

S5

"MePro"

HART Transmitter configuration and data-acquisition program

WIN MESO

HART

no

HART modem (communicator)

product of INOR

RS485

no

IA300

"InfoPrint"

configuration program for IA300 interface adapter / printer / datalogger

WIN IA300

S6 S7

"InfoMonitor"

data-acquisition program for TC800

WIN TC800

RS485

no

IA150

WIN LCSUPx (EchoTrack)

no

"EView"

viewing and configuration software for ultrasonic level transmitters w/ HART interface

HART

S8

HART modem (communicator)

S9

"PolyMonitor" program

universal data-acquisition

WIN all w/ RS485

RS485

no

IA100 IA250

S10

"UniConf"

universal configuration program

WIN all

RS232 RS485

S11

"Process"

single-process monitoring and recording program

WIN RT390

RS232

no

no

S12

"ThermLog"

temperature data-acquisition program for TC800

DOS TC800

RS485

no

IA150 (1)

S13

"ProfiSoft"

transmitter configuration and data-acquisition program

WIN TRP (ProfIPAQ)

RS232

yes

no

S14

"HartTemp"

HART Transmitter configuration and data-acquisition program

WIN TRH

HART

no

HART modem (communicator)

discontinued (1) product of NIVELCO

depending on device connected

product of Raycho Raykov product of INOR

Contact COMECO

COMECO reserves the right of changing specifications without prior notice!

(1)

product of INOR

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org


miscellaneous Software

Code

Software

Description

OS Devices Interface

Special Cable

Interface Adapter no

Notes

S1

"MiniSoft"

transmitter configuration and data-acquisition program

WIN MiniPAQ

RS232

yes

S2

"RStest"

simple program for RS232 or RS485 communication test

WIN all

RS232 RS485

depending on device connected

S3

"TraCon"

transmitter configuration and data-acquisition program

WIN TRB(I), TRY, RS232 TRZ, TRC

yes

no

free download from www.tracon.bz

S4

"Ipro"

transmitter configuration and data-acquisition program

WIN TRS (IPAQ)

RS232

yes

no

product of INOR

S5

"MePro"

HART Transmitter configuration and data-acquisition program

WIN MESO

HART

no

HART modem (communicator)

product of INOR

RS485

no

IA300

"InfoPrint"

configuration program for IA300 interface adapter / printer / datalogger

WIN IA300

S6 S7

"InfoMonitor"

data-acquisition program for TC800

WIN TC800

RS485

no

IA150

WIN LCSUPx (EchoTrack)

no

"EView"

viewing and configuration software for ultrasonic level transmitters w/ HART interface

HART

S8

HART modem (communicator)

S9

"PolyMonitor" program

universal data-acquisition

WIN all w/ RS485

RS485

no

IA100 IA250

S10

"UniConf"

universal configuration program

WIN all

RS232 RS485

S11

"Process"

single-process monitoring and recording program

WIN RT390

RS232

no

no

S12

"ThermLog"

temperature data-acquisition program for TC800

DOS TC800

RS485

no

IA150 (1)

S13

"ProfiSoft"

transmitter configuration and data-acquisition program

WIN TRP (ProfIPAQ)

RS232

yes

no

S14

"HartTemp"

HART Transmitter configuration and data-acquisition program

WIN TRH

HART

no

HART modem (communicator)

discontinued (1) product of NIVELCO

depending on device connected

product of Raycho Raykov product of INOR

Contact COMECO

COMECO reserves the right of changing specifications without prior notice!

(1)

product of INOR

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org


miscellaneous Software

Code

Software

Description

OS Devices Interface

Special Cable

Interface Adapter no

Notes

S1

"MiniSoft"

transmitter configuration and data-acquisition program

WIN MiniPAQ

RS232

yes

S2

"RStest"

simple program for RS232 or RS485 communication test

WIN all

RS232 RS485

depending on device connected

S3

"TraCon"

transmitter configuration and data-acquisition program

WIN TRB(I), TRY, RS232 TRZ, TRC

yes

no

free download from www.tracon.bz

S4

"Ipro"

transmitter configuration and data-acquisition program

WIN TRS (IPAQ)

RS232

yes

no

product of INOR

S5

"MePro"

HART Transmitter configuration and data-acquisition program

WIN MESO

HART

no

HART modem (communicator)

product of INOR

RS485

no

IA300

"InfoPrint"

configuration program for IA300 interface adapter / printer / datalogger

WIN IA300

S6 S7

"InfoMonitor"

data-acquisition program for TC800

WIN TC800

RS485

no

IA150

WIN LCSUPx (EchoTrack)

no

"EView"

viewing and configuration software for ultrasonic level transmitters w/ HART interface

HART

S8

HART modem (communicator)

S9

"PolyMonitor" program

universal data-acquisition

WIN all w/ RS485

RS485

no

IA100 IA250

S10

"UniConf"

universal configuration program

WIN all

RS232 RS485

S11

"Process"

single-process monitoring and recording program

WIN RT390

RS232

no

no

S12

"ThermLog"

temperature data-acquisition program for TC800

DOS TC800

RS485

no

IA150 (1)

S13

"ProfiSoft"

transmitter configuration and data-acquisition program

WIN TRP (ProfIPAQ)

RS232

yes

no

S14

"HartTemp"

HART Transmitter configuration and data-acquisition program

WIN TRH

HART

no

HART modem (communicator)

discontinued (1) product of NIVELCO

depending on device connected

product of Raycho Raykov product of INOR

Contact COMECO

COMECO reserves the right of changing specifications without prior notice!

(1)

product of INOR

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org


other control instrumentation 8-channel Isolated Current Scanner ICM81 ♦ ♦ ♦ ♦ ♦ ♦ ♦

Triple isolation 8 internally powered input current loops Input current limiter Different retransmission output signals Isolated parallel interface for external control Isolated alarm outputs Self-testing and system-failure alarm

ICM81 is an 8-channel externally-controlled scanner / multiplexer of DC current signals to an isolated linear output, available in 2-wire current and 3-wire current and voltage versions. The scanner provides isolation DC power supply for all input current loops with common ground together with an automatic over-current protection and has a 3-bit isolated parallel port for external channel selection from PLC. ICM81 is equipped with sophisticated alarm circuit providing isolated alarm outputs and LED indication in case of input break and overload, output failure, and internal error. Designed for DIN-rail mounting, with its convenient plastic enclosure and detachable screw terminals, ICM81 can be very useful in industrial applications requiring DC current multiplexing with isolation, extending PLC analog input possibilities.

Technical specifications Analog inputs Number of inputs Input signal Operating range Absolute range Resolution Scanning period Input connection Input-loop power supply (ILPS) ILPS current limitation Isolation between analog inputs Isolation from main power supply

(scanned inputs) 8 DC current 0...20 mA or 4....20 mA 0...22 mA approx. 10-bit 5s 2-wire or 3-wire externally or internally (1) powered 180 mA none (common ground and supply) 1000 V

Addressing input Input configuration Logic '0' Logic '1' Consumption Input function Isolation from analog inputs

3-bit parallel port not connected connected to power supply > 12 VDC < 2 mA at logic '1' remote channel selection 2500 V

Current output - maximum load Voltage output - minimum load Resolution Output delay Output connection Isolation from analog inputs Isolation from main power supply

(3)

Measurement error Temperature drift

0.2% from span 0.01% from span for 1 °C

Power supply Supply voltage Consumption

24 VDC ± 10% max. 250 mA

Indication 'PWR' green LED 'BREAK' red LED 'OVRLD' red LED Blinking LEDs

retransmission of selected input channel 0....20 mA or 4...20 mA 750 Ω at 24V/20mA 0...10 V 1 MΩ approx. 12-bit max. 50 ms 3-wire 1000 V none (common ground)

Operating temperature Operating humidity

for device power ON for selected input channel under range for selected input channel over range for output current loop error or system failure

Case material Mounting Wiring Dimensions Weight Protection, front/terminals

Code values

G6

Analog inputs (2)

DB - 0…20 mA, DC - 4…20 mA, Z - other (3)

G11

Analog output

E - 0…20 mA, F - 4…20 mA, K - 0…10 V, Z - other (3)

All analog inputs are of a same type! Contact COMECO

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

-10...65 °C 0...85 %RH

Design and materials

ICM81 - G6.G11

Code Feature or option

(2)

Accuracy

Provides isolated loop supply voltage - 24V/180mA for all input channels!

Ordering code

MOS gate 0.1A/60V not connected connected to common ground (0 V) input signal under- or over-range 2500 V

Operating conditions

Output function

(1)

Output type Logic '0' Logic '1' (active alarm) Outputs function Isolation from analog inputs

plastic on 35 mm DIN rail plug-in terminals 70x110x58 mm max. 150 g IP54 / IP20

COMECO reserves the right of changing specifications without prior notice!

Analog output

Alarm outputs


other control instrumentation Remote Set-point Unit TC10 ♦ ♦ ♦ ♦

Easy and convenient set-point setting via rotating dial Passive or active input channel 48x48 DIN-sized front panel Panel or rail mounting

TC10 is a self-contained unit for remote set-point setting. Replacing scrolling through controller menus with simple turning of a dial, the unit is used as accessory for programmable controllers when set point has to be changed frequently. Another TC10 application is in cases, in which there is a need to adjust the set point from a remote location – far from controller panel. Two variants are available: passive – providing resistive output signal (5 kΩ potentiometer) – and active – generating current or voltage signal proportional to set-point value. The TC10 unit is a convenient supplement to COMECO's RT controller series and other manufacturers’ automation systems.

Technical specifications Output

Power supply 0...5 kΩ 0...5 kΩ 0...max. 1 MΩ 0(4)...20 mA 0...1 V, 0...2 V, 0...5 V, or 0...10 V 0...max. 40 mA or 0...max. 10 V

Passive, resistive Passive, potentiometer Other passive (1) Active, DC current Active, DC voltage Other active (1)

Accuracy 1% from span 0.01% from span for 1 °C 0.2% per year

Setting accuracy Temperature drift Long-term stability

Indication and controls 270° arc 40 or 50, depending on the range 0…100%, 0…100 °C, 0…200 °C, 0…400 °C, 0…750 °C, 0…1000 °C, or other on request LED for active output

Dial Dial divisions Dial range (2)

LEDs (1) (2) (3)

Mains supply voltage Isolated low voltage Consumption

230 VAC or 115 VAC 12…24 V or 24 VAC max. 2 VA

Operating conditions Ambient temperature Ambient humidity

-10...65 °C 0...85 %RH

Design and materials Case material Mounting Wiring Dimensions Mounting depth Weight Protection, front/terminals

plastic in 45x45 mm panel cut-out or on 35 mm DIN rail socket OCTAL (3) 48x48(front)x95 mm max. 103 mm (w/ socket) max. 250 g IP40 / IP20

Custom; specify range within the limits stated Specify dial range when ordering. Ordered separately (see 'Accessories')

Ordering code

TC10 - G1.G11

Code Feature or option G1

Variant Power supply

Analog output

P - passive, A - active passive

X - none

active

A - 230 VAC, B - 115 VAC, Q - 12…24 V, isolated, R - 24 VAC

passive

N - resistive, P - potentiometer, Z - other (1)

active, current

E - 0...20 mA, F - 4...20 mA, Z - other (1)

active, voltage

G - 0...1 V, H - 0...2 V, I - 0...5 V, K - 0...10 V, Z - other (1)

COMECO reserves the right of changing specifications without prior notice!

G11

Code values

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


other control instrumentation Protection Unit for 3-phase AC Motors TC70 ♦ ♦ ♦ ♦ ♦ ♦

Low cost Monitors LINE (phase) presence and order Monitors phase voltage magnitude Monitors NEUTRAL (zero) presence Overheating-protection input from PTC High reliability

TC70 is a specialized device for monitoring and protection of 3-phase asynchronous motors, designed for DIN-rail mounting. It monitors phase presence and order, phase line voltage, and zero presence, and switches off its relay output in the cases of failure. An additional input for connecting a thermistor with positive temperature coefficient (posistor) is used for monitoring motor temperature. A cheap, yet highly reliable device, TC70 can be used not only for motor protection, but also in all cases, in which 3-phase system power supply should be monitored.

Technical specifications Input

Power supply

LINE control input (3-phase) NEUTRAL control input Temperature input

3 x 380 VAC ± 15% 220 VAC ± 15% PTC (RPTC at 25 °C = 1k, 2k, or other)

Output

230 VAC +10/-15% max. 4 VA

Operating conditions

Relay electromechanical Solid state relay Output function

Temperature control Indication (1)

Supply voltage Consumption

3A/250V w/ NO/NC contact 1A/250VAC switches off in situations (1): (a) missing line (R/S/T) or neutral (N), (b) line voltage exceeds 270 ± 10 V, (c) line voltage drops below 170 ± 10 V, (d) line order is not RST, STR, or TRS switches off when PTC indicates 70 °C LED for relay ON

Operating temperature Operating humidity

-10...65 °C 0...85 %RH

Design and materials Case material Mounting Wiring Dimensions Weight Protection, case/terminals

plastic on 35 mm DIN rail screw terminals 45x78x108 mm max. 300 g IP40 / IP00

Other phase voltages than the described in points (b) and (c) may be monitored if requested.

Ordering code

TC70 - G5.G6

Code Feature or option

Code values

Relay output

C - relay NO/NC, D - SSR

G6

Temperature control input

BP - PTC 1k, BQ - PTC 2k, BZ - other PTC (specify!)

COMECO reserves the right of changing specifications without prior notice!

G5

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


other control instrumentation RPM Controller for 1-phase AC Motors SCRM ♦ ♦ ♦ ♦ ♦

AC motor power from 0.5 to 5 A / 230 VAC 0…100% speed control Automatic triac retriggering Variant with soft start Load-current sensing available

The SCRM rail-mountable RPM controller, manufactured by COMECO, is designed to control the speed of single-phase AC motors up to 5A/230VAC. The unit operates on the principle of 'phase angle control' from 25 to 180 degrees, adjusted by a front-panel thumbwheel and applied to an internal power triac. SCRM can switch up to 500 VA AC motors of fans or other industrial appliances, connected to the device output. A soft-starter variant allows the motor to reach gradually the pre-adjusted speed, while the 'loadcurrent sensing' option allows keeping the motor speed relatively constant and independent on the load. Thanks to its reliability and simplicity, the SCRM controller can be widely used in applications requiring low-cost AC-motor speed control.

Technical specifications Motor output

Power supply

Control output type Maximum motor power ratings Non rep. surge current at t = 20 ms Minimum holding current Maximum leakage current Critical rate of current rise dI/dt Critical off-state voltage rise dV/dt I2t value for fusing at t = 10 ms Fusing

phase-controlled triac 0.5...5 A / 230 VAC 50 A 50 mA 2 mA 50 A/μs 1000 V/μs 78 A2s by external fuses

Device variants

Control feedbacks Mains voltage compensation Load-current sensing (option) (2) (2)

230 VAC or 115 VAC ± 10% max. 2.5 VA

Operating conditions Operating temperature Temperature drift Operating humidity

-10...40 °C max. 0.05% for 1 °C 0...85 %RH

Indication and controls LEDs Front-panel potentiometer (2)

LED for power ON for speed set-point adjustment, 0…100%

Design and materials 25...180° phase angle 0 to max. speed for ≈ 2 s (1)

RPM controller Soft-starter

(1)

Supply voltage Consumption

≈ 1% of set-point angle per 10 V ≈ 10% of set-point angle per 1 A

Case material Mounting Wiring Dimensions Weight Protection class

plastic on 35 mm DIN rail screw terminals, 2.5 mm2 max. 35x86x58 mm max. 80 g IP40

The time depends on motor current. Only for RMP controller variant!

Ordering code

SCRM - G1 - #1

Code Feature or option

Code values 1 - RPM controller, 2 - soft-starter

G1

Power supply

A - 230 VAC, B - 115 VAC

#1

Load-current sensing (2)

X - none, LS - load-current compensation mounted

COMECO reserves the right of changing specifications without prior notice!

Variant

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


accessories Mounting Accessories for Electronic Devices MA Code

View

Description

Mounting

Application

MAC1

metal clamp for DIN-rail mounting

clamp

for all in-head transmitters; for devices in 40x73x26 mm box (TSR, TSOR, IA250, etc.)

MAC2

set of 2 plastic clamps for DIN-rail mounting

clamp

for devices in 80x80x60 mm box (TI200-Y, RT38-Y, TRx-D, TRU, PSF200, etc.)

clamp

MAC3

plastic clamp for DIN-rail mounting with metal holder

for all in-head transmitters; for devices in 40x73x26 mm box (TSR, TSOR, IA250, etc.); for devices in 50x45x32 mm box (RHA, TSP, TSOP, etc.)

for devices in 40x73x26 mm box (TSR, TSOR)

MAC4

plastic clamp for DIN-rail mounting

clamp

set of 4 stainless steel threaded bushes with nuts

female thread M6

for axial mounting of devices in 65x65x40 mm or 80x80x60 mm box (TI200-Y, RT38-Y, TRx-D, TRU, PSF200, RHW, etc.)

stainless steel threaded nipple with nut

male thread M12; female thread M8

for radial mounting of devices in 65x65x40 mm or 80x80x60 mm box (TI200-Y, RT38-Y, TRx-D, TRU, PSF200, RHW, etc.)

8-pin socket base (OCTAL) for DIN-rail mounting

clamp

for devices in 48x48 mm front-sized case ('S')

11-pin socket base (UNDECAL) for DIN-rail mounting

clamp

for devices in 48x48 mm front-sized case ('S') and devices in other 11-pin boxes (TRZ, RT38-R, TI08-R, etc.)

8-pin socket base (OCTAL) for DIN-rail mounting, EN50022

clamp

for devices in 48x48 mm front-sized case ('S')

MAB3

clamp

MAB4

11-pin socket base (UNDECAL) for DIN-rail mounting, EN50022; Lloyd's Register Approval

for devices in 48x48 mm front-sized case ('S') and devices in other 11-pin boxes (TRZ, RT38-R, TI08-R, etc.)

MAA1

MAR1

MAB1

MAB2

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

for all in-head transmitters


accessories Mounting Accessories for Electronic Devices MA Code

View

Description

Mounting

Application

MAC1

metal clamp for DIN-rail mounting

clamp

for all in-head transmitters; for devices in 40x73x26 mm box (TSR, TSOR, IA250, etc.)

MAC2

set of 2 plastic clamps for DIN-rail mounting

clamp

for devices in 80x80x60 mm box (TI200-Y, RT38-Y, TRx-D, TRU, PSF200, etc.)

clamp

MAC3

plastic clamp for DIN-rail mounting with metal holder

for all in-head transmitters; for devices in 40x73x26 mm box (TSR, TSOR, IA250, etc.); for devices in 50x45x32 mm box (RHA, TSP, TSOP, etc.)

for devices in 40x73x26 mm box (TSR, TSOR)

MAC4

plastic clamp for DIN-rail mounting

clamp

set of 4 stainless steel threaded bushes with nuts

female thread M6

for axial mounting of devices in 65x65x40 mm or 80x80x60 mm box (TI200-Y, RT38-Y, TRx-D, TRU, PSF200, RHW, etc.)

stainless steel threaded nipple with nut

male thread M12; female thread M8

for radial mounting of devices in 65x65x40 mm or 80x80x60 mm box (TI200-Y, RT38-Y, TRx-D, TRU, PSF200, RHW, etc.)

8-pin socket base (OCTAL) for DIN-rail mounting

clamp

for devices in 48x48 mm front-sized case ('S')

11-pin socket base (UNDECAL) for DIN-rail mounting

clamp

for devices in 48x48 mm front-sized case ('S') and devices in other 11-pin boxes (TRZ, RT38-R, TI08-R, etc.)

8-pin socket base (OCTAL) for DIN-rail mounting, EN50022

clamp

for devices in 48x48 mm front-sized case ('S')

MAB3

clamp

MAB4

11-pin socket base (UNDECAL) for DIN-rail mounting, EN50022; Lloyd's Register Approval

for devices in 48x48 mm front-sized case ('S') and devices in other 11-pin boxes (TRZ, RT38-R, TI08-R, etc.)

MAA1

MAR1

MAB1

MAB2

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

for all in-head transmitters


accessories Mounting Accessories for Electronic Devices MA Code

View

Description

Mounting

Application

MAC1

metal clamp for DIN-rail mounting

clamp

for all in-head transmitters; for devices in 40x73x26 mm box (TSR, TSOR, IA250, etc.)

MAC2

set of 2 plastic clamps for DIN-rail mounting

clamp

for devices in 80x80x60 mm box (TI200-Y, RT38-Y, TRx-D, TRU, PSF200, etc.)

clamp

MAC3

plastic clamp for DIN-rail mounting with metal holder

for all in-head transmitters; for devices in 40x73x26 mm box (TSR, TSOR, IA250, etc.); for devices in 50x45x32 mm box (RHA, TSP, TSOP, etc.)

for devices in 40x73x26 mm box (TSR, TSOR)

MAC4

plastic clamp for DIN-rail mounting

clamp

set of 4 stainless steel threaded bushes with nuts

female thread M6

for axial mounting of devices in 65x65x40 mm or 80x80x60 mm box (TI200-Y, RT38-Y, TRx-D, TRU, PSF200, RHW, etc.)

stainless steel threaded nipple with nut

male thread M12; female thread M8

for radial mounting of devices in 65x65x40 mm or 80x80x60 mm box (TI200-Y, RT38-Y, TRx-D, TRU, PSF200, RHW, etc.)

8-pin socket base (OCTAL) for DIN-rail mounting

clamp

for devices in 48x48 mm front-sized case ('S')

11-pin socket base (UNDECAL) for DIN-rail mounting

clamp

for devices in 48x48 mm front-sized case ('S') and devices in other 11-pin boxes (TRZ, RT38-R, TI08-R, etc.)

8-pin socket base (OCTAL) for DIN-rail mounting, EN50022

clamp

for devices in 48x48 mm front-sized case ('S')

MAB3

clamp

MAB4

11-pin socket base (UNDECAL) for DIN-rail mounting, EN50022; Lloyd's Register Approval

for devices in 48x48 mm front-sized case ('S') and devices in other 11-pin boxes (TRZ, RT38-R, TI08-R, etc.)

MAA1

MAR1

MAB1

MAB2

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

for all in-head transmitters


accessories Mounting Accessories for Electronic Devices MA Code

View

Description

Mounting

Application

MAC1

metal clamp for DIN-rail mounting

clamp

for all in-head transmitters; for devices in 40x73x26 mm box (TSR, TSOR, IA250, etc.)

MAC2

set of 2 plastic clamps for DIN-rail mounting

clamp

for devices in 80x80x60 mm box (TI200-Y, RT38-Y, TRx-D, TRU, PSF200, etc.)

clamp

MAC3

plastic clamp for DIN-rail mounting with metal holder

for all in-head transmitters; for devices in 40x73x26 mm box (TSR, TSOR, IA250, etc.); for devices in 50x45x32 mm box (RHA, TSP, TSOP, etc.)

for devices in 40x73x26 mm box (TSR, TSOR)

MAC4

plastic clamp for DIN-rail mounting

clamp

set of 4 stainless steel threaded bushes with nuts

female thread M6

for axial mounting of devices in 65x65x40 mm or 80x80x60 mm box (TI200-Y, RT38-Y, TRx-D, TRU, PSF200, RHW, etc.)

stainless steel threaded nipple with nut

male thread M12; female thread M8

for radial mounting of devices in 65x65x40 mm or 80x80x60 mm box (TI200-Y, RT38-Y, TRx-D, TRU, PSF200, RHW, etc.)

8-pin socket base (OCTAL) for DIN-rail mounting

clamp

for devices in 48x48 mm front-sized case ('S')

11-pin socket base (UNDECAL) for DIN-rail mounting

clamp

for devices in 48x48 mm front-sized case ('S') and devices in other 11-pin boxes (TRZ, RT38-R, TI08-R, etc.)

8-pin socket base (OCTAL) for DIN-rail mounting, EN50022

clamp

for devices in 48x48 mm front-sized case ('S')

MAB3

clamp

MAB4

11-pin socket base (UNDECAL) for DIN-rail mounting, EN50022; Lloyd's Register Approval

for devices in 48x48 mm front-sized case ('S') and devices in other 11-pin boxes (TRZ, RT38-R, TI08-R, etc.)

MAA1

MAR1

MAB1

MAB2

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

for all in-head transmitters


accessories Adjustable Mounting Flange FA DIN 43734 FLANGE Material - cast black steel (see Appendix - Sheath materials) Coating - electrostatically coated powder paint

NOMINAL SIZE

DIMENSIONS d1 (tube OD) [mm]

DN16

DN22

DN32

14...16

20...22

30...32

A [mm]

75

90

90

B [mm]

50

65

65

C [mm]

55

70

70

D [mm]

27

33

33

Fixing: 2 stainless steel screws M6x16 Maximum temperature: 300 째C Maximum pressure: atmosphere

Ordering code

FA - G4

Code Feature or option G4

Nominal size

DN16 (1), DN22, DN32 (1)

Contact COMECO!

COMECO reserves the right of changing specifications without prior notice!

(1)

Code values

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


accessories DIN Mounting Flange FD DIN 1092-1 VARIANT *

D (FDDx)

FACE *

Material - stainless steel (see Appendix - Sheath materials) Nominal pressure - PN25...PN100

A

B

D

F

flat

raised

groove

recess

G

H

O-ring recess O-ring groove

DESIGN WITHOUT NECK (01)

DESIGN WITH WELDING NECK (11) DESIGN WITH THREADED NECK (13)

Maximum temperature: 850 °C * Other standard types and faces are available on request. Please contact COMECO!

Nominal size

DN10

DN15

DN20

DN25

DN32

DN40

DN50

DN65

18 (3/8") 90

22 (1/2") 95

27.5 (3/4") 105

34.5 (1") 115

43.5 (1¼") 140

49.5 (1½") 150

61.5 (2") 165

77.5 (2½") 185

14 / 16 60

14 / 16 65

16 / 18 75

16 / 18 85

18 100

18 110

20 125

22 145

d3 [mm]

30

35

45

52

60

70

84

104

h1 [mm]

22

22

26

28

30

32

34

38

d4 [mm]

40

45

58

68

78

88

102

122

d1 D [mm] b1 / b2 [mm] k [mm]

w [mm] y / z [mm] r [mm] d2 [mm] Bolts

29

36

43

51

61

73

95

40 / 28 4

51 / 35 4

58 / 42 4

66 / 50 6

76 / 60 6

88 / 72 6

110 / 94 6

14

14

14

14

18

18

18

18

4 x M12

4 x M12

4 x M12

4 x M12

4 x M16

4 x M16

4 x M16

8 x M16

FDD - G4.G5.G9.G10.G14

Code Feature or option

(1) (2)

Code values

Design

01 - w/o neck, 11 - w/ welding neck, 13 - w/ treaded neck

G4

Nominal size

DN10, DN15, DN20, DN25, DN32, DN40, DN50, DN65, Z - other (specify!) (1)

G5

Tube diameter (for welding) 'd1' [mm]

X - none (blind flange), 18...77.5 (2), Z - other

G9

Connection thread 'd1'

X - none, U3 - G3/8", U4 - G1/2", U6 - G3/4", U12 - G1", U27 - G1¼", U13 - G1½", U14 - G2", Z - other (specify!) (1)

G10

Material

M1 - 1.4301, M2 - 1.4541 (1), M3 - 1.4571 (1), M9 - 1.4404 or 1.4435, Z - other (specify!) (1)

G14

Face

A - flat, B - raised, D - groove, F - recess, G - O-ring recess, H - O-ring groove

Contact COMECO! Applicable for the selected size

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code

24 35 / 23 4


accessories

SHORT-NECK VARIANT FOR TUBE WELDING Material - stainless steel (see Appendix - Sheath materials) Nominal pressure - PN40

**

**

W (FDW)

THREADED DIN 2566 VARIANT Material - stainless steel (see Appendix - Sheath materials) Nominal pressure - PN16...PN40

T (FDT)

** DIN 2633 welding neck flanges and ANSI RF flanges are also available on request. Please contact COMECO!

Nominal size

DN6

DN8

d1 thread d1 tube for welding [mm]

1/8"

1/4" 8, 10, 12

DN10

DN15

3/8" 1/2" 12, 14, 16

DN20

DN25

DN32

DN40

3/4" 1" 16, 20, 25

1¼" 1½" 25, 32, 40

DN50 2"

DN65

2½" 40, 50, 65

D [mm]

75

80

90

95

105

115

140

150

165

185

b [mm] k [mm]

12 50

12 55

14 60

14 65

16 75

16 85

16 100

16 110

18 125

18 145

d3 [mm]

20

25

30

35

45

52

60

70

85

105

h1 [mm]

18

18

20

20

24

24

26

26

28

32

d4 [mm]

32

38

40

45

58

68

78

88

102

122

f [mm] r [mm]

2 2

2 2

2 3

2 3

2 4

2 4

2 5

3 5

3 5

3 6

s [mm] Bolts

1.5

1.5

1.8

2

2.3

2.6

2.6

2.6

2.9

2.9

4 x M10

4 x M10

4 x M12

4 x M12

4 x M12

4 x M12

4 x M16

4 x M16

4 x M16

8 x M16

d2 [mm] Weight [kg]

11

14

14

14

14

18

18

18

18

0.38

0.54

0.61

0.91

1.10

1.60

1.78

2.43

3.18

FD - G4.G5.G9.G10

Code Feature or option G4

Code values

Variant

W - for tube welding, T - threaded DN6, DN8, DN10, DN15, DN20, DN25, DN32, DN40, DN50, DN65, Z - other (specify!) (1)

Nominal size (3)

X - none (blind flange), 8...65 (2), Z - other

G5

Tube diameter (for welding) 'd1' [mm]

G9

Connection thread 'd1' (2,4)

X - none, U3 - G3/8", U4 - G1/2", U6 - G3/4", U12 - G1", U27 - G1¼", U13 - G1½", U14 - G2", Z - other (specify!) (1)

G10

Material

M1 - 1.4301, M2 - 1.4541 (1), M3 - 1.4571 (1), M9 - 1.4404 or 1.4435, Z - other (specify!) (1)

(1)

Contact COMECO! Applicable for the selected size Code only for variant 'W'! (4) Code only for variant 'T'! (2)

(3)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code

11 0.33


accessories ANSI Mounting Flange FN ANSI B16.5 BLIND FLANGE

B (FNB)

Material - stainless steel (see Appendix - Sheath materials) Nominal pressure - PN25...PN100

DIMENSIONS * SIZE 1/2"

NO DRILL

3/4"

1"

DRILLED FOR PIPE WELDING

1 ¼"

1 ½"

2"

2 ½"

DRILLED AND THREADED

3"

pipe OD D k G class [mm] [mm] [mm] [mm] 21.3

26.7

33.4

42.2

48.3

60.3

73.0

88.9

150 300 600 150 300 600 150 300 600 150 300 600 150 300 600 150 300 600 150 300 600 150 300 600

88.9

60.5

95.2

66.5

98.6

69.8

117.3

82.5

108

79.2

124

35.1

42.9

50.8 88.9

117.3 133.4

63.5 98.5

127 155.4

114.3

152.4

120.6

165.1

127

177.8

139.7

190.5

149.2

190.5

152.4

209.5

168.1

73.2

91.9

104.8

127

b1 RF d2 holes [mm] [mm] [mm] 9.7 12.7 14.2 11.2 14.2 15.7 12.7 16 17.5 14.2 18 20.6 16 19 22.3 17.5 20.8 25.4 20.9 23.9 28.4 22.4 26.9 31.7

1.5 6.3

15.7

1.5 6.3 1.5 6.3 1.5 6.3 1.5 6.3 1.5

19 15.7 19 15.7 19 15.7

6.3 1.5 6.3

4

22.3 19

6.3 1.5

4

8

19

4

22.3

8

19

4

22.3

8

weight [kg] ≈ 0.42 ≈ 0.64 ≈ 0.76 ≈ 0.61 ≈ 1.11 ≈ 1.28 ≈ 0.86 ≈ 1.39 ≈ 1.60 ≈ 1.17 ≈ 1.79 ≈ 2.23 ≈ 1.53 ≈ 2.66 ≈ 3.25 ≈ 2.42 ≈ 3.18 ≈ 4.15 ≈ 3.94 ≈ 4.85 ≈ 6.13 ≈ 4.93 ≈ 6.81 ≈ 8.44

Maximum temperature: 850 °C Maximum pressure: class 150 - 150 psig class 300 - 300 psig class 600 - 600 psig * Other standard types and dimensions are available on request. Please contact COMECO!

FNB - G4'/4".G5.G9.G10.G14

Code Feature or option

(1)

Code values

G4'

Nominal size

50 - 1/2", 75 - 3/4", 100 - 1", 125 - 1¼", 150 - 1½", 200 - 2", 250 - 2½", 300 - 3", Z - other (specify!) (1)

G4"

Nominal pressure (class)

150 - 10 bar (150 psig), 300 - 20 bar (300 psig), 600 - 40 bar (600 psig)

G5

Pipe diameter (for welding) 'd1' [mm]

X - none (blind flange), OD (see table above)

G9

Connection thread 'd1'

X - none, U4 - G1/2", U10 - NPT 1/2", U6 - G3/4", U11 - NPT 3/4", U12 - G1", U15 - NPT 1", U27 - G1¼", U28 - NPT 1¼", U13 - G1½", U16 - NPT 1½", U14 - G2", U17 - NPT 2", U21 - G3", U22 - NPT 3", Z - other (specify!) (1)

G10

Material

M1 - 1.4301, M2 - 1.4541 (1), M3 - 1.4571 (1), M9 - 1.4404 or 1.4435, Z - друг (поясни!) (1)

G14

Face

A - flat, B - raised

Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code


accessories Small Mounting Flange FS SMALL MOUNTING FLANGE Material - aluminum, brass, or stainless steel (see Appendix - Sheath materials) Application - with TS, LC, and RH probes

NOMINAL SIZE *

DIMENSIONS

DN5 DN6 DN8 DN9 DN10 DN12 DN14 DN16 DN18 d1 (probe OD) [mm] D [mm]

5

6

8

9

10

12

14

16

18

32

34

40

40

42

44

46

48

50

b [mm]

2 (stainless steel), 3 (brass), or 4 (aluminum)

k [mm]

24

26

30

30

32

34

36

38

40

d3 [mm]

13

14

18

19

20

22

24

26

28

h1 [mm]

14

14

16

16

16

16

16

18

18

no. of bolts

2

2

3

3

4

4

4

4

4

Fixing: stainless steel screw M4 Maximum temperature: 300 째C Maximum pressure: atmosphere * Other dimensions are available on request. Please contact COMECO!

Ordering code

FS - G4.G10

Code Feature or option Nominal size

DN5, DN6, DN8, DN9, DN10, DN12, DN14, DN16, DN18, Z - other (specify!)

G10

Material

AL - aluminum, BR - brass (Ni-plated) (1), M1 - 1.4301, M2 - 1.4541 (1), M3 - 1.4571 (1), M9 - 1.4404

Contact COMECO!

COMECO reserves the right of changing specifications without prior notice!

(1)

Code values

G4

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


accessories Mounting Adapter YB BAYONET MOUNTING ADAPTER

YBx

DIMENSIONS *

Material - aluminum, brass, or stainless steel (see Appendix - Sheath materials) Application - with TS bayonet probes

E

SCREW DESIGN (1)

M10x1.5

SW

K1 [mm]

D [mm]

H2 [mm]

Spring OD [mm]

12 (13)

6

14 (15)

7

9

M10x1

10 G1/8"

Bayonet Cap [mm]

-

10...100

1/8" NPT 10 12

M12x1.5 M10x1.5 M10x1

WRENCH DESIGN (2)

G1/8"

14

1/8" NPT

G1/4"

17

12

M16x1.5 19

3/8" NPT

10...100

12 (13)

12

15 (16)

12 / 15

15 (16) / 18 (19)

15

1/4" NPT G3/8"

10

10

M12x1.5 M14x1.5

9

13

12...100 15

6, 7

6, 7, 8 18 (19)

15

Maximum temperature: 850 °C Maximum pressure: atmosphere * Other dimensions are available on request. Please contact COMECO!

YB - G4.G6.G9'.G9".G10

Code Feature or option

(1) (2)

Code values

Design

1 - screw, 2 - wrench

G4

Spring outer diameter 'd' [mm] (1)

6, 7, 8

G6

Bayonet length 'H2' [mm]

10…100 (see table above)

(1)

X - none (2), Q0 - M16x1.5, Q3 - G3/8", Q7 - M12x1.5, Q8 - M14x1.5, Q9 - 3/8" NPT, Q18 - G1/8", Q19 - 1/8" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Q30 - M10x1.5, Z - other (specify!) (2)

G9'

Connection thread 'E'

G9"

Bayonet diameter 'D' [mm] (1)

10, 12, 15, Z - other (specify!) (2)

G10

Material

AL - aluminum, BR - brass (Ni-plated) (2), M1 - 1.4301, M2 - 1.4541 (2), M3 - 1.4571 (2), M9 - 1.4404

Applicable for the selected design Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code


accessories Mounting Adapter YD THREADED MOUNTING ADAPTER

YDx

DIMENSIONS *

Material - stainless steel (see Appendix - Sheath materials) Application - with probes series TS, LC, PS, etc.

E M10x1(1.5); G1/8"

STANDARD M/M DESIGN (1)

1/8" NPT; M12x1.5 M14x1.5; G1/4" 1/4" NPT M16x1.5; G3/8" 3/8" NPT M18x1.5 M20x1.5; G1/2" 1/2" NPT M27x2; G3/4" 3/4" NPT M33x2; G1" 1" NPT M10x1(1.5); G1/8"

EXTENDED M/F DESIGN (2)

1/8" NPT; M12X1.5 M14x1.5; G1/4" 1/4" NPT M16x1.5; G3/8" 3/8" NPT M18x1.5 M20x1.5; G1/2" 1/2" NPT M27x2; G3/4" 3/4" NPT M33x2; G1" 1" NPT M16x1.5; G3/8"

LOW-PROFILE M/F DESIGN (3)

3/8" NPT M18x1.5 M20x1.5; G1/2" 1/2" NPT M27x2; G3/4" 3/4" NPT M33x2; G1" 1" NPT

SW 17 19 22 24 27 32 36 17

19 22 24 27 32 36 22 24 27 32 36

K1 [mm]

N

H2 [mm]

dmax [mm]

M8 / M10 / M12 G1/8" / 1/8" NPT

8 / 9 / 10 9 / 10

5/6/6 5/5

as above; M14 / G1/4" / 1/4" NPT

as above; 12 / 12 / 15

as above; 8/6/6

15

as above; M16 / G3/8" / 3/8" NPT

as above; 13 / 13 / 15

as above; 10 / 10 / 10

13

as above; M18x1.5

as above; 13

as above; 10

15

as above; M20 / G1/2" / 1/2" NPT

as above; 15 / 15 / 20

as above; 12

as above; M27 / G3/4" / 3/4" NPT

as above; 17 / 17 / 20

as above; 16

as above; M33 / G1" / 1" NPT

as above; 19 / 19 / 25

as above; 20

M8 / M10 / M12 / M14 G1/8"(NPT) / G1/4"(NPT)

8 / 9 / 10 / 12 8 / 11

6 / 6 / 8 / 10 6/8

as above; M16 / G3/8" / 3/8" NPT

as above; 13 / 13 / 12

as above; 12 / 12 / 12

as above; M18

as above; 14

as above; 14

as above; M20 / G1/2"(NPT)

as above; 15 / 15

as above; 16 / 16

as above; M27 / G3/4" / 3/4" NPT

as above; 17 / 17 / 16

as above; 20 / 20 / 20

as above; M33 / G1" / 1" NPT

as above; 19 / 19 / 18

as above; 20 / 20 / 20

15

M8 / M10 / M12 G1/8"(NPT) / G1/4"(NPT)

8 / 9 / 10 8 / 11

6/6/8 6/8

13

as above; M14

as above; 12

as above; 10

15

as above; M16 / G3/8" / 3/8" NPT

as above; 13 / 13 / 12

as above; 12 / 12 / 12

as above; M18 / M20 / G1/2"(NPT)

as above; 14 / 15 / 15

as above; 14 / 16 / 16

as above; M27 / G3/4" / 3/4" NPT

as above; 17 / 17 / 16

as above; 20 / 20 / 20

9 10 12 15 13

20 17 20 19 25 9 10 12 15 13 15 13 15 20 17 20 19 25 13

20 17 20 19 25

* Other dimensions are available on request. Please contact COMECO! M16x1.5; G3/8"

GLAND-TYPE DESIGN (4)

3/8" NPT M18x1.5 M20x1.5; G1/2" 1/2" NPT M27x2; G3/4" 3/4" NPT M33x2; G1" 1" NPT

22 24 27 32 36

13

3...8

15 13 15 20 17

N and SW1 are specified by the manufacturer

20 19 25

Maximum temperature: dependant on ferrule material Maximum pressure: 6(10) bar DN = d

* Other dimensions are available on request. Please contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

3...8 4...12 4...12 6...16 6...16 8...20

COMECO reserves the right of changing specifications without prior notice!

Maximum temperature: 850 째C Maximum pressure: 40 bar


accessories

Ordering code

YD - G4.G9'G9".G10'G10"

Code Feature or option

Code values

Design

1 - standard m/m, 2 - extended m/f, 3 - low-profile m/f, 4 - gland-type

Probe diameter 'd' [mm] (1)

1.5, 2, 3, 4, 4.5, 5, 6, 8, 10, 12, 14, 16, 20

Connection thread 'E' (1)

X - none (4), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q7 - M12x1.5, Q8 - M14x1.5, Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q18 - G1/8", Q19 - 1/8" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Q25 - M33x2, Q30 - M10x1.5, Z - other (specify!)

G9"

Probe thread 'N' (1,2)

X - none (4), Q0/U0 - M16x1.5, Q1/U1 - M18x1.5, Q2/U2 - M20x1.5, Q3/U3 - G3/8", Q4/U4 - G1/2", Q5/U5 - M27x2, Q6/U6 - G3/4", Q7/U7 - M12x1.5, Q8/U8 - M14x1.5, Q9/U9 - 3/8" NPT, Q10/U10 - 1/2" NPT, Q11/U11 - 3/4" NPT, Q12/U12 - G1", Q15/U15 - 1" NPT, Q18/U18 - G1/8", Q19/U19 - 1/8" NPT, Q20/U20 - M10x1, Q23/U23 - G1/4", Q24/U24 - 1/4" NPT, Q25/U25 - M33x2, Q26/U26 - M8x1, Q29/U29 - M8x1.25, Q30/U30 - M10x1.5, Z - other (specify!)

G10'

Material

G4 G9'

G10"

Compression fitting ferrule

M1 - 1.4301, M2 - 1.4541 (4), M3 - 1.4571 (4), M9 - 1.4404 or 1.4435, Z - other (specify!) (4) (3)

TF - Teflon®, BR - brass, SS - stainless steel

(1)

COMECO reserves the right of changing specifications without prior notice!

Applicable for the selected design (2) Omit for YD4! (3) Only for YD4! (4) Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


accessories Mounting Bracket YT PIPE-MOUNTING BRACKET

YTx

Material - steel or stainless steel (see Appendix - Sheath materials) Application - pipe mounting for field devices

DIMENSIONS * Design

Pipe Size

1

½" to 1½"

2

1½" to 2"

3

½" to 1½"

4

1½" to 2"

A [mm]

B [mm]

125

108

145

126

L [mm] 80 106 80 106

Tighten up: wrench size 10 Applications: - designs '1' and '2' are suitable for instrument housings with 108 mm mounting distance (e.g. EX8 or EX8W) - designs '3' and '4' are suitable for instrument housings with 126 mm mounting distance (e.g. EX10 or EX10W)

* Other dimensions are available on request. Please contact COMECO!

Ordering code

YT - G10

Code Feature or option Design

1, 2, 3, 4

G10

Material

M1 - 1.4301, M2 - 1.4541, M13 - mild (black) steel (Zn-plated (1))

Contact COMECO!

COMECO reserves the right of changing specifications without prior notice!

(1)

Code values

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


accessories Mounting Adapter YQ WELDED MOUNTING BUSH Material - stainless steel (see Appendix - Sheath materials) Application - with YP thermowells or separately

DIMENSIONS * Thermowell OD

Connection Thread M20x1.5, M27x2

≤ 17 mm

G1/2", G3/4" 1/2" NPT, 3/4" NPT M27x2, M33x2

≤ 30 mm

G3/4", G1" ¾" NPT, 1" NPT

Maximum temperature: 850 °C Maximum pressure: 63 bar

* Other dimensions are available on request. Please contact COMECO!

Ordering code

YQ - G9.G10

Code Feature or option G9

Connection thread

G10

Material

M1 - 1.4301, M2 - 1.4541 (1), M3 - 1.4571 (1), M9 - 1.4404 or 1.4435, Z - other (specify!) (1)

Contact COMECO!

COMECO reserves the right of changing specifications without prior notice!

(1)

Code values X - none, Q2 - M20x1.5, Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Z - other (specify!)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


accessories Protecting Accessories for Electronic Devices PA

Code

PAX1_ 0 1 2 3 PAX2_ 0 1 2 3 4 PAX3_ 0 1 2 3 4 PAX4_

Description IP65 ABS plastic box 65x65x40 mm, with mounting plate

Mounting

Application

free, wall, or rail (with clamp MAC4)

for protection of devices with maximum overall dimensions 40x40x25 mm or ø45x25 mm (e.g. low-profile in-head transmitters)

free, wall, or rail (with clamp MAC2)

for protection of devices with maximum overall dimensions 45x45x40 mm or ø50x40 mm (e.g.: in-head transmitters; devices in case type 'M')

free, wall, or rail (with clamp MAC2)

for high protection of devices with maximum overall dimensions 45x45x40 mm or ø50x40 mm (e.g.: in-head transmitters; devices in case type 'M')

free, wall, or rail (with clamp MAC2)

for Ex protection of devices with maximum overall dimensions 45x45x40 mm or ø50x40 mm

- without cable glands - with 1 plastic gland PG7 - with 2 glands PG7 at 90 ° - with 2 glands PG7 at 180 ° IP65 ABS plastic box 80x80x60 mm, with mounting plate - without cable glands - with 1 plastic gland PG7 - with 2 glands PG7 - with 2 glands PG7 at 90 ° - with 2 glands PG7 at 180 ° IP67 Aluminum box 82x77x57 mm, with mounting plate - without cable glands - with 1 metal gland PG7 - with 2 glands PG7 - with 2 glands PG7 at 90 ° - with 2 glands PG7 at 180 ° IP67 Aluminum Ex box 82x77x57 mm, with mounting plate - without cable glands - with 1 Ex gland PG7

(e.g.: in-head transmitters) Approval: Ex e II, EN 50014; IK

- with 2 glands PG7 - with 2 glands PG7 at 90 ° - with 2 glands PG7 at 180 °

COMECO reserves the right of changing specifications without prior notice!

0 1 2 3 4

View

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


accessories Explosion-proof Instrument Housing EX Variant

8

10

Specifications pressure die-cast aluminum (max. 0.5% Mg), painted with chemically resistant paint, or stainless steel grade AISI 316 (1)

Material Overall dimensions

125x105.5x94.5(height) mm

145x125.5x107(height) mm

ø90 mm / M80

ø110 mm / M100 with locking screw

Lid Conduits Cable glands

3x 1/2" NPT up to 3x ATEX brass glands for non-armored cables 6...8 mm OD (2) (option)

Sensor mounting

via central conduit

Wall mounting

2 holes ø7x108 mm

Pipe mounting

2 holes ø7x126 mm with pipe-mounting bracket (see 'Accessories')

Protection

Ex 'd' IIC; aluminum: IP68, stainless steel: IP66

Approvals Ambient temperature

ATEX 94/9/EC Ex 'd' II GD (for Zone 1/ 2/ 21/ 22) -40...100 °C

Space for transmitter

max. ø60x60 mm

Variant

8W

max. ø85x75 mm

10W

8WD

10WD

Specifications pressure die-cast aluminum (max. 0.5% Mg), painted with chemically resistant paint, or stainless steel grade AISI 316 (1)

Material

125x105.5x109.5(height) mm ø90 mm / M80

145x125.5x127(height) mm ø110 mm / M100 with locking screw

Conduits

105x106.5x162(height) mm 2 x ø90 mm / M80

115x126.5x206(height) mm 2 x ø110 mm / M100 with locking screw

3x 1/2" NPT up to 3x ATEX brass glands for non-armored cables 6...8 mm OD (2) (option)

Cable glands Sensor mounting

via central conduit

Wall mounting

2 holes ø7x108 mm

Pipe mounting Protection

2 holes ø7x126 mm

none

with pipe-mounting bracket (see 'Accessories') Ex 'd' IIC; aluminum: IP68, stainless steel: IP66

Approvals

none

ATEX 94/9/EC Ex 'd' II GD (for Zone 1/ 2/ 21/ 22)

Ambient temperature

-40...85 °C

Space for transmitter

max. ø60x65 mm

Space for indicator

max. ø85x85 mm

max. ø60x28 mm

max. ø85x45 mm

max. ø65x50 mm

max. ø85x75 mm

(1)

Not available for dual-compartment variants! (2) Other cable glands for armored or non-armored cables are available on request.

Ordering code

EX - G10 - #1

Code Feature or option

Code values

Variant

8, 10 - closed, 8W, 10W - windowed, 8WD, 10WD - windowed, dual-compartment

G10

Material

AL - painted aluminum, SS - stainless steel 316 (1)

#1

ATEX cable glands

X - none, CG - 1 cable gland mounted, 2CG - 2 cable glands mounted, 3CG - 3 cable glands mounted

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Overall dimensions Lid


accessories Threaded Bored Thermowell YPTB

YPTB

Material - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes STANDARD TIP

DIMENSIONS * E M20x1.5; G1/2”

SW K1

27

14

N

H2 [mm]

H1 [mm]

d1 [mm]

M14x1.5; G3/8”

15

20...100

4 / 5.5

20

25...100

7

15

20...100

4 / 5.5

14

20

25...100

7/9

17

M27x2; G3/4"

25

30...100

M14x1.5; G3/8”

15

20...100

4 / 5.5

14

20

25...100

7/9

17 / 19

M27x2; G3/4"

25

30...100

M33x2; G1"

30

35...100

M18x1.5 M20x1.5; G1/2" M14x1.5; G3/8”

M27x2; G3/4"

M33x2; G1"

32

16

36

18

1/2” NPT

27

25

3/4" NPT

32

25

1" NPT

NARROWED TIP

M20x1.5; G1/2”

M27x2; G3/4"

M33x2; G1"

Manufactured from solid HEX or round bar

36

27

32

36

25

14

16

18

1/2” NPT

27

25

3/4" NPT

32

25

L = U + K1 + H1

1" NPT

M20x1.5; G1/2"

M18x1.5

Manufactured from solid HEX or round bar L = U + K1 + H1

M18x1.5

36

25

M20x1.5; G1/2"

F1 [mm] 14

7 / 9 / 11 17 / 19 / 21

3/8” NPT

15

20...100

4 / 5.5

1/2" NPT

20

25...100

7 4 / 5.5

13

7/9

16

3/8” NPT

15

20...100

1/2" NPT

20

25...100

3/4" NPT

25

30...100

3/8” NPT

15

20...100

4 / 5.5

13

20

25...100

7/9

16

3/4" NPT

25

30...100

1" NPT

30

35...100

M14x1.5; G3/8”

15

20...100

M18x1.5

20

25...100

20

25...100

M14x1.5; G3/8”

15

20...100

M18x1.5

20

25...100

M20x1.5; G1/2"

20

25...100

M27x2; G3/4"

25

30...100

M14x1.5; G3/8”

15

20...100

M18x1.5

20

25...100

M20x1.5; G1/2"

20

25...100

M27x2; G3/4"

25

30...100

M33x2; G1"

30

35...100

7 / 9 / 11 16 / 18 / 20 4 / 5.5 7

7/9

7/9

20...100

4 / 5.5

20

25...100

7 4 / 5.5

15

20...100

20

25...100

3/4" NPT

25

30...100

≈ 24

7/9

≈ 30

17 / 19 17 / 19 / 21

≈ 17

13 13

≈ 23

16

3/8” NPT

15

20...100

4 / 5.5

13

1/2" NPT

20

25...100

7/9

16

3/4" NPT

25

30...100

1" NPT

30

35...100

≈ 27

7 / 9 / 11

Probe diameter: d ≤ d1 - 1 Probe thread: G = N Probe length (incl. thread): fixed: n = 0.98 * L - e (DIN) or 0.98 * L - e + 0.5 * H2 (NPT) spring-loaded: n ≈ L - e (DIN) or L - e + 0.5 * H2 (NPT) Maximum temperature: 850 °C Maximum pressure: 100 bar

16 / 18 / 20

INSERTION LENGTH d1 [mm]

U [mm]

<7

max. 300

7...9

max. 500

11

max. 700

* Other dimensions are available on request. Please contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

17 14

7 / 9 / 11

15

14 14

4 / 5.5

3/8” NPT 3/8” NPT

≈ 18

4 / 5.5

1/2" NPT 1/2" NPT

= F1

13

1/2" NPT

M20x1.5; G1/2"

F3 [mm]

COMECO reserves the right of changing specifications without prior notice!

THREADED BORED THERMOWELL


accessories

Ordering code

YPTB - G4.G6.G7.G9'G9".G10.G14

Code Feature or option

Code values

G4

Probe diameter 'd' [mm]

3, 4.5, 5, 6, 8, 10

G6

Length 'U' [mm]

50…700 (see table overleaf) (1)

G7

Length 'H1' [mm] (1)

20…100 (see table overleaf) (1)

G9'

Connection thread 'E' (1)

X - none (2), Q2 - M20x1.5, Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Z - other (specify!)

G9"

Probe thread 'N' (1)

X - none (2), U1 - M18x1.5, U2 - M20x1.5, U3 - G3/8", U4 - G1/2", U5 - M27x2, U6 - G3/4", U8 - M14x1.5, U9 - 3/8" NPT, U10 - 1/2" NPT, U11 - 3/4" NPT, U12 - G1", U15 - 1" NPT, U25 - M33x2, Z - other (specify!)

G10

Material

M1 - 1.4301, M2 - 1.4541 (2), M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)

G14

Tip shape

X - standard closed, N - narrowed

(1)

COMECO reserves the right of changing specifications without prior notice!

Applicable for the selected probe diameter 'd' (2) Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


accessories Threaded DIN Thermowell YPTD

DIN 43772-2 THERMOWELL

YPTDx

Material - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes

DIMENSIONS * FORM

BORED DESIGNS (B6, B7, B9)

E

SW

G1/2"

27

D1 K1 [mm] [mm] 26

14

N

H1 H2(K2) [mm] [mm]

M20x1.5; G1/2"

d1 F1(F2) [mm] [mm] 7

19

15

9 / 11

17

7/9 6

G3/4"

G1"

32

41

32

39

1/2" NPT

16

18

M27x2; G3/4" M20x1.5; G1/2"

22 19

17 15

3/4" NPT

-

1" NPT

36

G1/2"

27

≈ 21

14

M20x1.5; G1/2"

15

12 -

G3/4"

WELDED DESIGNS (W5, W8)

19

M20x1.5; G1/2"

9 Maximum pressure: 100 bar

32

32

16

G1/2"

27

26

14

G3/4"

32

32

16

17

9 / 11

20 / 22 17

9 / 11

≈ 25 26

19 / 20

7 7

≈ 20 27

7

7/9 11 / 13

M27x2; G3/4" M20x1.5; G1/2"

14

19

15

5

7/9 7

17

9 / 11

20 / 22

7

G1/2"

27

26

14

M20x1.5; G1/2"

G3/4"

32

32

16

M27x2; G3/4"

8

22

17 12

14

17

9 / 11 7/9 11 / 13

19 / 20

7

12

9 / 11

14

7/9 M27x2; G3/4"

19

11

7/9 11 / 13

12 / 14 14 / 16

7

12

9 / 11

14

7/9

12 / 14

11 / 13

14 / 16

Probe diameter: d ≤ d1 - 1 Probe thread: G = N Probe length: n = U1+18 (fixed) or n = U1+23 (spring-loaded); + 10 mm (FORM7) Maximum pressure: 25 bar (s=1.5) or 40 bar (s=2.5)

Maximum temperature: 850 °C * Other dimensions are available on request. Please contact COMECO!

YPTD - G4.G6.G9'G9".G10

Code Feature or option

Design

Code values B6 - bored, FORM 6, B7 - bored, FORM 7, B9 - bored, FORM 9, W5 - welded, FORM 5, W8 - welded, FORM 8

G4

Probe diameter 'd' [mm]

6, 8, 10, 12

G6

Length 'U1' [mm]

50…500 (see table above) (1)

G9'

Connection thread 'E' (2)

X - none (3), Q4 - G1/2", Q6 - G3/4", Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Z - other (specify!)

G9"

Probe thread 'N' (2)

X - none (3), Q2 - M20x1.5, U2 - M20x1.5, Q4 - G1/2", U4 - G1/2", Q5 - M27x2, U5 - M27x2, Q6 - G3/4", U6 - G3/4", Z - other (specify!)

G10

Material

M1 - 1.4301, M2 - 1.4541 (3), M3 - 1.4571 (3), M9 - 1.4404 or 1.4435, Z - other (specify!) (3)

(1)

Other lengths are available upon request. Contact COMECO! Applicable for the selected probe diameter (3) Contact COMECO! (2)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code


accessories Threaded Gland-type Thermowell YPTG GLAND-TYPE THERMOWELL

YPTGx

Sheath - stainless steel (see Appendix - Sheath materials) Ferrule - stainless steel, brass, or Teflon®

DIMENSIONS * E

D1 K1 SW [mm] [mm]

M20x1.5; G1/2"

BORED DESIGN (B)

d1 [mm]

F1 [mm]

N

SW1

26

15

-

≈ 20

31

16

4/5/6/7/9

17

G1/4"

13

-

≈ 21

11 / 13

19

G3/8"

17

35

17

-

≈ 25

21

13

-

15

6, 7, 8, 9

8, 10, 12

G1/4"

13

23

13

6, 7, 8, 9, 10 11

8, 10, 12 14

G1/4" G3/8"

13 17

6, 7, 8, 9, 10 11, 12, 13

8, 10, 12 14, 16

G1/4" G3/8"

13 17

6, 7, 8, 9, 10 11, 12, 13, 16

8, 10, 12, 14, 16, 20

G1/4" G3/8"

13 17

27 1/2" NPT M27x2; G3/4" 32 3/4" NPT M33x2; G1" Maximum pressure: 100 bar

36 1" NPT

Manufactured from solid HEX or round bar

M16x1.5; G3/8"

WELDED DESIGN (W)

3/8" NPT M18x1.5 M20x1.5; G1/2" 1/2" NPT M27x2; G3/4" 3/4" NPT M33x2; G1" 1" NPT

Maximum pressure: 25 bar

22 24 27 32 36

26

15

-

≈ 20

31

16

-

≈ 21

35

17

-

≈ 25

Probe diameter: d = DN ≤ d1 - 1 Free probe length: n ≥ U1+30 Maximum temperature: dependant on ferrule material * Other dimensions are available on request. Please contact COMECO!

YPTG - G4.G6.G9'G9".G10

Code Feature or option

(1) (2)

Code values

Design

B - bored, W - welded

G4

Probe diameter 'd' [mm]

3, 4, 4.5, 5, 6, 8, 10, 12

G6

Length 'U1' [mm]

30…500 (see table above)

G9'

Connection thread 'E' (1)

X - none (2), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Z - other (specify!)

G9"

Compression fitting ferrule

TF - Teflon® (up to 200 °C), BR - brass (up to 400 °C), SS - stainless steel (up to 800 °C)

G10

Sheath material

M1 - 1.4301, M2 - 1.4541 (2), M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)

Applicable for the selected probe diameter Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code


accessories Threaded Thermowell with Fixing Screw YPTS THERMOWELL WITH FIXING SCREW

YPTSx

Sheath - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes

DIMENSIONS * FORM

BORED DESIGN (B)

E

N D1 K1 SW [mm] [mm] [mm]

M20x1.5; G1/2" 1

**

27

26

15

-

≈ 20

d1 [mm]

7 / 9 / 11 M20x1.5; G1/2" 2 ***

22

M16x1.5; G3/8"

WELDED DESIGN (W)

d1

≈ 20

22

3/8" NPT 1 **

M18x1.5

24

M20x1.5; G1/2"

27

14.5 ****

1/2" NPT M16x1.5; G3/8"

21

13

-

15

23

13

26

15

-

≈ 20 13

19

3/8" NPT 2 *** Maximum probe length: n = U1+4 Maximum pressure: 25 bar

6 / 8 / 9(10)

5/6/8

8 / 10 / 12

6/8 9(10) / 11

5/6 8 / 10

8 / 10 12 / 14

6 / 8 / 9(10)

5/6/8

8 / 10 / 12

6/8 9(10) / 11

5/6 8 / 10

8 / 10 12 / 14

15 d1

M18x1.5 M20x1.5; G1/2"

6 / 8 / 10 13 / 15 / 17

15

1/2" NPT

Manufactured from solid HEX or round bar

F1 [mm]

14.5 ****

1/2" NPT

Maximum probe length: n = U1-2 Maximum pressure: 100 bar

d [mm]

22

1/2" NPT

1

13 15 ≈ 20

Free probe length: n ≥ U1+13 Fixing screw: M4, stainless steel Maximum temperature: 450 °C * Other dimensions are available on request. Please contact COMECO! ** for temperature gauges *** for TS probes **** gauge neck + 0.5 mm

YPTS - G4.G6.G9.G10

Code Feature or option

(1) (2)

Design

Code values B1 - bored, FORM1, B2 - bored, FORM2, W1 - welded, FORM1, W2 - welded, FORM2

G4

Probe diameter 'd' [mm]

5, 6, 8, 10

G6

Length 'U1' [mm]

30…300 (see table above)

G9

Connection thread 'E' (1)

X - none (2), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Z - other (specify!)

G10

Material

M1 - 1.4301, M2 - 1.4541 (2), M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)

Applicable for the selected probe diameter Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code


accessories Threaded Tapered Thermowell YPTT THREADED TAPERED THERMOWELL

YPTT

Material - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes

DIMENSIONS * E M20x1.5; G1/2”

SW K1 27

14

N

H2 [mm]

H1 [mm]

d1 [mm]

M14x1.5; G3/8”

15

20...100

4 / 5.5

20

25...100

7

15

20...100

4 / 5.5

14

20

25...100

7/9

17

M18x1.5 M20x1.5; G1/2" M14x1.5; G3/8”

M27x2; G3/4"

M33x2; G1"

Manufactured from solid HEX or round bar

32

16

M20x1.5; G1/2"

36

18

27

25

3/4" NPT

32

25

36

25

L = U + K1 + H1

F1 [mm]

14

≈ 18

≈ 24

M27x2; G3/4"

25

30...100

M14x1.5; G3/8”

15

20...100

4 / 5.5

14

20

25...100

7/9

17 / 19

M27x2; G3/4"

25

30...100

M33x2; G1"

30

35...100

M18x1.5

1/2” NPT

1" NPT

M18x1.5

F3 [mm]

M20x1.5; G1/2"

7 / 9 / 11 17 / 19 / 21

3/8” NPT

15

20...100

4 / 5.5

1/2" NPT

20

25...100

7 4 / 5.5

13

7/9

16

3/8” NPT

15

20...100

1/2" NPT

20

25...100

3/4" NPT

25

30...100

13

3/8” NPT

15

20...100

4 / 5.5

13

1/2" NPT

20

25...100

7/9

16

3/4" NPT

25

30...100

1" NPT

30

35...100

Probe diameter: d ≤ d1 - 1 Probe thread: G = N Probe length (incl. thread): fixed: n = 0.98 * L - e (DIN) or 0.98 * L - e + 0.5 * H2 (NPT) spring-loaded: n ≈ L - e (DIN) or L - e + 0.5 * H2 (NPT) Maximum temperature: 850 °C Maximum pressure: 160 bar

≈ 30

≈ 17

≈ 23

≈ 27

7 / 9 / 11 16 / 18 / 20

INSERTION LENGTH d1 [mm]

U [mm]

<7

max. 300

7...9

max. 500

11

max. 700

* Other dimensions are available on request. Please contact COMECO!

YPTT - G4.G6.G7.G9'G9".G10

Code Feature or option

(1) (2)

Code values

G4

Probe diameter 'd' [mm]

3, 4.5, 5, 6, 8, 10

G6

Length 'U' [mm]

50…700 (see table above) (1) (1)

20…100 (see table above) (1)

G7

Length 'H1' [mm]

G9'

Connection thread 'E' (1)

X - none (2), Q2 - M20x1.5, Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Z - other (specify!)

G9"

Probe thread 'N' (1)

X - none (2), U1 - M18x1.5, U2 - M20x1.5, U3 - G3/8", U4 - G1/2", U5 - M27x2, U6 - G3/4", U8 - M14x1.5, U9 - 3/8" NPT, U10 - 1/2" NPT, U11 - 3/4" NPT, U12 - G1", U15 - 1" NPT, U25 - M33x2, Z - other (specify!)

G10

Material

M1 - 1.4301, M2 - 1.4541 (2), M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)

Applicable for the selected probe diameter 'd' Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code


accessories Threaded Welded Thermowell YPTW YPTW

Material - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes STANDARD TIP

DIMENSIONS * E M20x1.5; G1/2”

M27x2; G3/4"

M33x2; G1"

SW K1

27

32

36

14

16

18

1/2” NPT

27

25

3/4" NPT

32

25

Manufactured from solid HEX or round bar U = 50...1500 mm L = U + K1 + H1 S = 1...3 mm 1" NPT

NARROWED TIP

M20x1.5; G1/2”

M27x2; G3/4"

M33x2; G1"

S1

36

27

32

36

25

14

16

18

1/2” NPT

27

25

3/4" NPT

32

25

Manufactured from solid HEX or round bar U = 50...1500 mm L = U + K1 + H1 S = 1...3 mm S1 = 1...2 mm

1" NPT

36

25

N

H2 [mm]

H1 [mm]

M14x1.5; G3/8”

15

20...100

M18x1.5

20

25...100

M20x1.5; G1/2"

20

25...100

M14x1.5; G3/8”

15

20...100

M18x1.5

20

25...100

M20x1.5; G1/2"

20

25...100

M27x2; G3/4"

25

30...100

M14x1.5; G3/8”

15

20...100

M18x1.5

20

25...100

M20x1.5; G1/2"

20

25...100

M27x2; G3/4"

25

30...100

M33x2; G1"

30

35...100

3/8” NPT

15

20...100

1/2" NPT

20

25...100

3/8” NPT

15

20...100

1/2" NPT

20

25...100

3/4" NPT

25

30...100

3/8” NPT

15

20...100

1/2" NPT

20

25...100

3/4" NPT

25

30...100

1" NPT

30

35...100

M14x1.5; G3/8”

15

20...100

M18x1.5

20

25...100

M20x1.5; G1/2"

20

25...100

M14x1.5; G3/8”

15

20...100

M18x1.5

20

25...100

M20x1.5; G1/2"

20

25...100 30...100

M27x2; G3/4"

25

M14x1.5; G3/8”

15

20...100

M18x1.5

20

25...100

M20x1.5; G1/2"

20

25...100

M27x2; G3/4"

25

30...100

M33x2; G1"

30

35...100

3/8” NPT

15

20...100

1/2" NPT

20

25...100

3/8” NPT

15

20...100

1/2" NPT

20

25...100

3/4" NPT

25

30...100

3/8” NPT

15

20...100

1/2" NPT

20

25...100

3/4" NPT

25

30...100

1" NPT

30

35...100

Probe diameter: d ≤ (F3 - 2*S) - 1 Probe thread: G = N Probe length (incl. thread): fixed: n = 0.98 * L - e (DIN) or 0.98*L - e + 0.5*H2 (NPT) spring-loaded: n ≈ L - e (DIN) or L - e + 0.5*H2 (NPT) Maximum temperature: 850 °C

F1 [mm] 10, 12, 14, 1/8", 1/4"

10, 12, 14, 16, 18, 1/8", 1/4", 3/8"

10, 12, 14, 16, 18, 20, 1/8", 1/4", 3/8", 1/2"

= F1

10, 12, 14, 1/8", 1/4" 10, 12, 14, 16, 18, 1/8", 1/4", 3/8" 10, 12, 14, 16, 18, 20, 1/8", 1/4", 3/8", 1/2" 10, 12, 14, 1/8", 1/4"

8, 10

10, 12, 14, 16, 18, 1/8", 1/4", 3/8"

8, 10, 12

10, 12, 14, 16, 18, 20, 1/8", 1/4", 3/8", 1/2"

8, 10, 12, 14

10, 12, 14, 1/8", 1/4"

8, 10

10, 12, 14, 16, 18, 1/8", 1/4", 3/8"

8, 10, 12

10, 12, 14, 16, 18, 20, 1/8", 1/4", 3/8", 1/2"

8, 10, 12, 14

MAXIMUM PRESSURE S(S1) [mm]

P [bar]

1

16

1.5 (2)

25

2.5 (3)

40

* Other dimensions are available on request. Please contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

F3 [mm]

COMECO reserves the right of changing specifications without prior notice!

THREADED WELDED THERMOWELL


accessories

Ordering code

YPTW - G4.G6.G7.G9'G9".G10.G14

Code Feature or option

Code values 10, 12, 14, 16, 18, 20, 1/8" (2), 1/4" (2), 3/8" (2), 1/2" (2)

G4

Tube diameter 'F1' [mm]

G6

Length 'U' [mm]

50…1500 (see table overleaf)

G7

Length 'H1' [mm] (1)

20…100 (see table overleaf) (1)

G9'

Connection thread 'E' (1)

X - none (2), Q2 - M20x1.5, Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Z - other (specify!)

G9"

Probe thread 'N' (1)

X - none (2), U1 - M18x1.5, U2 - M20x1.5, U3 - G3/8", U4 - G1/2", U5 - M27x2, U6 - G3/4", U8 - M14x1.5, U9 - 3/8" NPT, U10 - 1/2" NPT, U11 - 3/4" NPT, U12 - G1", U15 - 1" NPT, U25 - M33x2, Z - other (specify!)

G10

Material

M1 - 1.4301, M2 - 1.4541 (2), M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)

G14

Tip shape

X - standard closed, N - narrowed

(1)

COMECO reserves the right of changing specifications without prior notice!

Applicable for the selected tube diameter 'F1' (2) Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


accessories Weldable DIN Thermowell YPWD DIN 43772-2 THERMOWELL

YPWD

DIMENSIONS * N

F2 [mm]

M14x1.5

18

9

4 / 5.5

M18x1.5

24

12.5

7

Sheath - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes

F3 [mm]

d1 [mm]

H1 H2 [mm] [mm] 16

L [mm]

U [mm]

13

M20x1.5 G1/2"

26

12.5 / 15

7/9

19

15

M27x2 G3/4"

32

15 / 17 / 19

9 / 11 / 13

22

17

110 / 140

65

170 / 200

125

260 / 410

125 / 275

Probe diameter: d = d1 - 1 Probe thread: G = N Probe length: n = 0.98 * L - 5 (fixed) or n ≈ L - 5 (spring-loaded) Maximum temperature: 850 °C Maximum pressure: 160(250*) bar * Other dimensions are available on request. Please contact COMECO!

DIN 43763 THERMOWELL

YPWDx

Sheath - stainless steel (see Appendix - Sheath materials) Application - with TS probes with M18x1.5 external thread

DIMENSIONS * FORM

L [mm]

U [mm]

1

140

65

2 3

200

125 65

4 5

260

6

255

125

F2 [mm]

F3 [mm]

d1 [mm]

b [mm]

24

12.5

7

3.5

30

16

9

4

24

12.5

7

3.5

30

16

9

4

Probe diameter: d = d1 - 1 Probe thread: G = M18x1.5 Probe length: n = 0.98 * L - b (fixed) or n ≈ L - b (spring-loaded) Maximum temperature: 850 °C Maximum pressure: 250(500*) bar * Other dimensions are available on request. Please contact COMECO!

YPW - G4.G6.G9.G10

Code Feature or option Variant

G4

Probe diameter 'd' [mm]

3, 4.5, 6, 8, 10, 12

G6

Length 'L' [mm]

110…410 (see table above) (1)

G9

Probe thread 'N' (2)

X - none (3), U1 - M18x1.5, U2 - M20x1.5, U4 - G1/2", U5 - M27x2, U6 - G3/4", U8 - M14x1.5, Z - other (specify!)

G10

Material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571 (3), M9 - 1.4404 or 1.4435, Z - other (specify!) (3)

(1) (2) (3)

Code values D - DIN 43772-2, D1 - DIN 43763, FORM1, D2 - DIN 43763, FORM2, D3 - DIN 43763, FORM3, D4 - DIN 43763, FORM4, D5 - DIN 43763, FORM5, D6 - DIN 43763, FORM6

Other lengths are available upon request. Contact COMECO! Applicable for the selected probe diameter Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code


accessories Weldable Gland-type Thermowell YPWG GLAND-TYPE THERMOWELL

DIMENSIONS *

Sheath - stainless steel (see Appendix - Sheath materials) Ferrule - stainless steel, brass, or Teflon®

U1 [mm]

L [mm]

15

45

30

60

50

80

80

110

100

130

d1 [mm]

DN(d) [mm]

F1 [mm]

N

D1 [mm]

4/5/6/7/9

3/4/5/6/8

8 / 9 / 10 / 11 / 13

G1/4"

20

Probe diameter: d ≤ d1 - 1 Free probe length: n ≥ U1+45 Maximum temperature: dependant on ferrule material Maximum pressure: up to 100 bar (depending on welding technology) * Other dimensions are available on request. Please contact COMECO!

Ordering code

YPWG - G4.G6.G9.G10

Code Feature or option

(2)

Probe diameter 'd' [mm]

3, 4, 4.5, 5, 6, 8, 10

G6

Length 'U1' [mm]

15…100 (see table above) (1)

G9

Compression fitting ferrule

TF - Teflon® (up to 200 °C), BR - brass (up to 400 °C), SS - stainless steel (up to 800 °C)

G10

Sheath material

M1 - 1.4301, M2 - 1.4541 (2), M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)

Other lengths are available upon request. Contact COMECO! Contact COMECO!

COMECO reserves the right of changing specifications without prior notice!

(1)

Code values

G4

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


accessories Weldable Thermowell with Fixing Screw YPWS THERMOWELL WITH FIXING SCREW

DIMENSIONS *

Sheath - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes

U1 [mm]

L [mm]

15

45

30

60

50

80

80

110

100

130

FORM

N [mm]

D1 [mm]

d1 [mm]

d [mm]

F1 [mm]

1 **

14.5 ****

20

7 / 9 / 11

6 / 8 / 10

11 / 13 / 15

2 ***

d1

18

6/7/9

5/6/8

10 / 11 / 13

Probe diameter: d ≤ d1 - 1 Maximum probe length: n = U1+5 Free probe length: n ≥ U1+45 Fixing screw: M4, stainless steel Maximum temperature: 450 °C Maximum pressure: up to 100 bar (depending on welding technology) * Other dimensions are available on request. Please contact COMECO! ** for temperature gauges *** for TS probes **** gauge neck + 0.5 mm

Ordering code

YPWS - G4.G6.G10

Code Feature or option

(2)

1 - FORM1, 2 - FORM2

G4

Probe diameter 'd' [mm]

3, 4, 4.5, 5, 6, 8, 10

G6

Length 'U1' [mm]

15…100 (see table above) (1)

G10

Material

M1 - 1.4301, M2 - 1.4541 (2), M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)

Other lengths are available upon request. Contact COMECO! Contact COMECO!

COMECO reserves the right of changing specifications without prior notice!

(1)

Code values

Form

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


accessories Flanged Bored Thermowell YPFB DIN-FLANGED BORED THERMOWELL

YPFBD

DIMENSIONS * N

H2 [mm]

M14x1.5, G3/8”

15

20

22

4 / 5.5

13 / 15

≈ 18

M18x1.5

20

25

28

7

17

≈ 24

M20x1.5, G1/2"

20

25

30

7/9

17 / 19

≈ 26

M27x2, G3/4"

25

30

35

7 / 9 / 11

17 / 19 / 21

≈ 31

Material - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes

H1 [mm]

F2 [mm]

d1 [mm]

F3 [mm]

F1 [mm]

INSERTION LENGTH

Probe diameter: d = d1 - 1 Probe thread: G = N Probe length (incl. thread): n = 0.98 * L - e (fixed) or n ≈ L - e (spring-loaded) Maximum temperature: 850 °C Maximum pressure: 40 bar

d1 [mm]

U [mm]

<7

max. 300

7...9

max. 500

11

max. 700

FLANGE DIMENSIONS * NOMINAL SIZE

D [mm]

DN10 DN15 DN20 DN25 DN32 DN40 DN50

L = U + b + H1 (flat face) or L = U + b + H1 + 2 (raised face)

90 95 105 115 140 150 165

k [mm] 60 65 75 85 100 110 125

b d2 [mm] [mm]

bolts

14 14

4 x M12

16 18

Flange type: DIN 2527 or EN DIN 1092-1 Maximum pressure: PN40

18

4 x M16

20

* Other dimensions are available on request. Please contact COMECO!

Ordering code

YPFBD - G4.G6.G8.G9.G10.G14

Code Feature or option

Code values

G4

Probe diameter 'd' [mm]

3, 4.5, 5, 6, 8, 10

G6

Length 'U' [mm]

50…700 (see table above) (1)

G8

Flange nominal size

DN10 (2), DN15, DN20, DN25, DN32, DN40, DN50, Z - other (specify!) (2)

G9

Probe thread 'N' (1)

Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q8 - M14x1.5, Z - other (specify!) (2)

G10

Material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)

G14

Flange face

A - flat (FF), B - raised (RF), D - groove, F - recess, G - O-ring recess, H - O-ring groove

(1)

COMECO reserves the right of changing specifications without prior notice!

Applicable for the selected probe diameter 'd' (2) Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


accessories

ANSI-FLANGED BORED THERMOWELL

YPFBA

DIMENSIONS *

Material - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes

N

H2 [mm]

H1 [mm]

F2 [mm]

d1 [mm]

F3 [mm]

F1 [mm]

3/8” NPT

20

25

28

4 / 5.5

13 / 15

≈ 24

1/2" NPT

25

30

32

7/9

17 / 19

≈ 28

3/4" NPT

30

35

35

7 / 9 / 11

17 / 19 / 21

≈ 31

INSERTION LENGTH

Probe diameter: d = d1 - 1 Probe thread: G = N Probe length (incl. thread): n = 0.98 * L - e + 0.4 * H2 (fixed) or n ≈ L - e + 0.4 * H2 (spring-loaded) Maximum temperature: 850 °C Maximum pressure: 40 bar

d1 [mm]

U [mm]

<7

max. 300

7...9

max. 500

11

max. 700

FLANGE DIMENSIONS [mm] * SIZE class 1/2"

3/4"

1"

1 ¼" L = U + b + H1 (flat face) or L = U + RF + b + H1 (raised face)

1 ½"

2"

150 300 600 150 300 600 150 300 600 150 300 600 150 300 600 150 300 600

D

k

b

88.9

60.5

95.2

66.5

98.6

69.8

9.7 12.7 14.2 11.2 14.2 15.7 12.7 16 17.5 14.2 18 20.6 16 19 22.3 17.5 20.8 25.4

117.3

82.5

108

79.2

124

88.9

117.3 133.4

98.6

127 155.4 114.3 152.4 120.6 165.1

127

RF

d2

holes

1.5 6.3

15.7 Flange type:

1.5 6.3 1.5 6.3 1.5 6.3 1.5 6.3 1.5

19

4

15.7

Maximum pressure:

19

class 150 - 150 psig class 300 - 300 psig class 600 - 600 psig

15.7 19 15.7

ANSI B16.5

4

(to fit thermowell specifications)

22.3 19

6.3

8

* Other dimensions are available on request. Please contact COMECO!

YPFBA - G4.G6.G8'/8".G9.G10.G14

Code Feature or option

Code values

G4

Probe diameter 'd' [mm]

3, 4.5, 5, 6, 8, 10

G6

Length 'U' [mm]

50…700 (see table above) (1)

G8'

Flange nominal size

50 - 1/2", 75 - 3/4", 100 - 1", 125 - 1¼", 150 - 1½", 200 - 2", Z - other (specify!) (2)

G8"

Flange nominal pressure (class)

150 - 10 bar (150 psig), 300 - 20 bar (300 psig), 600 - 40 bar (600 psig)

(1)

Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Z - other (specify!) (2)

G9

Probe thread 'N'

G10

Material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)

G14

Flange face

A - flat (FF), B - raised (RF), D - groove, F - recess, G - O-ring recess, H - O-ring groove

(1)

Applicable for the selected probe diameter 'd' (2) Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code


accessories Flanged Bored Step-Tip Thermowell YPFN DIN-FLANGED BORED STEP-TIP THERMOWELL

YPFND

Material - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes

DIMENSIONS * N

H2 [mm]

H1 [mm]

F2 [mm]

d1 [mm]

F1 [mm]

F3 [mm]

M14x1.5, G3/8”

15

20 + T

22

4 / 5.5

≈ 18

13...16

M18x1.5

20

25 + T

28

7

≈ 24

15...21

M20x1.5, G1/2"

20

25 + T

30

7/9

≈ 26

15 / 17...21

M27x2, G3/4"

25

30 + T

35

7 / 9 / 11

≈ 26 / 30 15 / 17 / 21...25

INSERTION LENGTH

Probe diameter: d = d1 - 1 Probe thread: G = N Probe length (incl. thread): n = 0.98 * L - e (fixed) or n ≈ L - e + 1 (spring-loaded) Maximum temperature: 850 °C Maximum pressure: 40 bar

d1 [mm]

U [mm]

<7

max. 300

7...9

max. 700

11

max. 1000

FLANGE DIMENSIONS * NOMINAL D k b d2 SIZE [mm] [mm] [mm] [mm]

L = U + b + H1 (flat face) or L = U + b + H1 + 2 (raised face) Fillet radius at root and step 1...3 mm Full penetration weld design is also available on request

DN10 DN15 DN20 DN25 DN32 DN40 DN50

90 95 105 115 140 150 165

60 65 75 85 100 110 125

bolts

DIN 2527 or EN DIN 1092-1

14 14

4 x M12

16 18

Flange type:

Maximum pressure: PN40 18

4 x M16

20

* Other dimensions are available on request. Please contact COMECO!

Ordering code

YPFND - G4.G5.G6.G7.G8.G9.G10.G14

Code Feature or option

Code values

G4

Probe diameter 'd' [mm]

3, 4.5, 5, 6, 8, 10

G5

Insertion diameter 'F1' [mm]

13…21 (see table above) (1)

G6

Shank length 'U' [mm]

50…1000 (2) (see table above) (1)

G7

Extension length 'T' [mm]

0…100

G8

Flange nominal size

DN10 (2), DN15, DN20, DN25, DN32, DN40, DN50, Z - other (specify!) (2)

G9

Probe thread 'N' (1)

U1 - M18x1.5, U2 - M20x1.5, U3 - G3/8", U4 - G1/2", U5 - M27x2, U6 - G3/4", U8 - M14x1.5, Z - other (specify!) (2)

G10

Material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)

G14

Flange face

A - flat (FF), B - raised (RF), D - groove, F - recess, G - O-ring recess, H - O-ring groove

Applicable for the selected probe diameter 'd' (2) Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(1)


accessories

ANSI-FLANGED BORED STEP-TIP THERMOWELL

DIMENSIONS *

YPFNA N

H2 [mm]

H1 [mm]

F2 [mm]

d1 [mm]

F1 [mm]

F3 [mm]

3/8” NPT

20

25 + T

28

4 / 5.5

≈ 24

13...21

1/2" NPT

25

30 + T

32

7/9

≈ 27

15 / 17...23

3/4" NPT

30

35 + T

35

7 / 9 / 11

≈ 26 / 30

15 / 17 / 21...25

Material - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes

INSERTION LENGTH

Probe diameter: d = d1 - 1 Probe thread: G = N Probe length (incl. thread): n = 0.98 * L - e (fixed) or n ≈ L (spring-loaded) Maximum temperature: 850 °C Maximum pressure: 100 bar

d1 [mm]

U [mm]

<7

max. 300

7...9

max. 700

11

max. 1000

FLANGE DIMENSIONS [mm] * SIZE class 1/2"

3/4"

1"

1 ¼" L = U + b + H1 (flat face) or L = U + RF + b + H1 (raised face) 1 ½"

Fillet radius at root and step 1...3 mm Full penetration weld design is also available on request

2"

150 300 600 900 150 300 600 900 150 300 600 900 150 300 600 900 150 300 600 900 150 300 600 900

D

k

b

88.9

60.5

95.2

66.5

9.7 12.7 14.2 22.3 11.2 14.2 15.7 25.4 12.7 16 17.5 28.4 14.2 18 20.6 28.4 16 19 22.3 31.7 17.5 20.8 25.4 38.1

120.6 98.6

82.5 69.8

117.3

82.5

130 108

88.9 79.2

124

88.9

149.3 101.6 117.3 88.9 133.4

98.6

158.7 111.2 127 98.6 155.4 114.3 177.8 123.9 152.4 120.6 165.1

127

215.9 165.1

RF 1.5 6.3 1.5

d2

holes

15.7

1.5

ANSI B16.5

22.3 15.7 19

6.3

Flange type:

4

19 6.3 1.5

25.4 15.7

(to fit thermowell specifications)

19 6.3 1.5

25.4 15.7

4

22.3 6.3 1.5 6.3

Maximum pressure: class 150 - 150 psig class 300 - 300 psig class 600 - 600 psig class 900 - 900 psig class 1500 - 1500 psig

22.3 15.7

Dimensions for classes 900 and 1500 are identical up to 2 ½" size!

28.4 19 8 25.4

* Other dimensions are available on request. Please contact COMECO!

YPFNA - G4.G5.G6.G7.G8'/8".G9.G10.G14

Code Feature or option

(1) (2)

Code values

G4

Probe diameter 'd' [mm]

3, 4.5, 5, 6, 8, 10

G5

Insertion diameter 'F1' [mm]

13…21 (see table above) (1)

G6

Shank length 'U' [mm]

50…1000 (2) (see table above) (1)

G7

Extension length 'T' [mm]

0…100

G8'

Flange nominal size

50 - 1/2", 75 - 3/4", 100 - 1", 125 - 1¼", 150 - 1½", 200 - 2", Z - other (specify!) (2)

G8"

Flange nominal pressure (class)

150 - 10 bar (150 psig), 300 - 20 bar (300 psig), 600 - 40 bar (600 psig), 900 - 60 bar (900 psig), 1500 - 100 bar (1500 psig)

G9

Probe thread 'N' (1)

U9 - 3/8" NPT, U10 - 1/2" NPT, U11 - 3/4" NPT, Z - other (specify!) (2)

G10

Material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)

G14

Flange face

A - flat (FF), B - raised (RF), D - groove, F - recess, G - O-ring recess, H - O-ring groove

Applicable for the selected probe diameter 'd' Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code


accessories Flanged Bored Straight Thermowell YPFS DIN-FLANGED BORED STRAIGHT THERMOWELL

YPFSD

Material - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes

DIMENSIONS * H2 [mm]

N

H1 [mm]

F2 [mm]

d1 [mm]

F1 [mm]

M14x1.5, G3/8”

15

20 + T

22

4 / 5.5

13…19

M18x1.5

20

25 + T

28

7

15…21

M20x1.5, G1/2"

20

25 + T

30

7/9

15…21 / 17…21

M27x2, G3/4"

25

30 + T

35

7 / 9 / 11

15…21 / 17…21 / 21

INSERTION LENGTH

Probe diameter: d = d1 - 1 Probe thread: G = N Probe length (incl. thread): n = 0.98 * L - e (fixed) or n ≈ L - e + 1 (spring-loaded) Maximum temperature: 850 °C Maximum pressure: 40 bar

d1 [mm]

U [mm]

<7

max. 300

7...9

max. 700

11

max. 1000

FLANGE DIMENSIONS * NOMINAL D k b d2 SIZE [mm] [mm] [mm] [mm]

L = U + b + H1 (flat face) or L = U + b + H1 + 2 (raised face) Fillet radius at root 1..3 mm Full penetration weld design is also available on request

Ordering code

DN10 DN15 DN20 DN25 DN32 DN40 DN50

90 95 105 115 140 150 165

60 65 75 85 100 110 125

bolts

14 14

4xM12

16 18

Flange type: DIN 2527 or EN DIN 1092-1 Maximum pressure: PN40

18

4xM16

20

* Other dimensions are available on request. Please contact COMECO!

YPFSD - G4.G5.G6.G7.G8.G9.G10.G14

Code Feature or option

Code values

G4

Probe diameter 'd' [mm]

3, 4.5, 5, 6, 8, 10

G5

Insertion diameter 'F1' [mm]

13…21 (see table above) (1)

G6

Shank length 'U' [mm]

50…1000 (2) (see table above) (1)

G7

Extension length 'T' [mm]

0…100

G8

Flange nominal size

DN10 (2), DN15, DN20, DN25, DN32, DN40, DN50, Z - other (specify!) (2)

G9

Probe thread 'N' (1)

U1 - M18x1.5, U2 - M20x1.5, U3 - G3/8", U4 - G1/2", U5 - M27x2, U6 - G3/4", U8 - M14x1.5, Z - other (specify!) (2)

G10

Material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)

G14

Flange face

A - flat (FF), B - raised (RF), D - groove, F - recess, G - O-ring recess, H - O-ring groove

Applicable for the selected probe diameter 'd' (2) Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

(1)


accessories

ANSI-FLANGED BORED STRAIGHT THERMOWELL

DIMENSIONS *

YPFSA N

H2 [mm]

H1 [mm]

F2 [mm]

d1 [mm]

F1 [mm]

3/8” NPT

20

25 + T

28

4 / 5.5

13…21

1/2" NPT

25

30 + T

32

7/9

15…21 / 17…21

3/4" NPT

30

35 + T

35

7 / 9 / 11

15…21 / 17…21 / 21

Material - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes

INSERTION LENGTH

Probe diameter: d = d1 - 1 Probe thread: G = N Probe length (incl. thread): n = 0.98 * L - e (fixed) or n ≈ L (spring-loaded) Maximum temperature: 850 °C Maximum pressure: 100 bar

d1 [mm]

U [mm]

<7

max. 300

7...9

max. 700

11

max. 1000

FLANGE DIMENSIONS [mm] * SIZE class 1/2"

3/4"

1"

1 ¼" L = U + b + H1 (flat face) or L = U + RF + b + H1 (raised face) 1 ½"

Fillet radius at root 1..3 mm Full penetration weld design is also available on request

2"

150 300 600 900 150 300 600 900 150 300 600 900 150 300 600 900 150 300 600 900 150 300 600 900

D

k

b

88.9

60.5

95.2

66.5

9.7 12.7 14.2 22.3 11.2 14.2 15.7 25.4 12.7 16 17.5 28.4 14.2 18 20.6 28.4 16 19 22.3 31.7 17.5 20.8 25.4 38.1

120.6 98.6

82.5 69.8

117.3

82.5

130 108

88.9 79.2

124

88.9

149.3 117.3

101.6 88.9

133.4

98.6

158.7 127

111.2 98.6

155.4

114.3

177.8 152.4

123.9 120.6

165.1

127

215.9

165.1

RF 1.5 6.3 1.5

d2

holes

15.7

19 6.3 1.5

Flange type: ANSI B16.5

22.3 15.7 4

19 6.3 1.5

25.4 15.7

(to fit thermowell specifications)

19 6.3 1.5

25.4 15.7

4

22.3 6.3 1.5 6.3

Maximum pressure: class 150 - 150 psig class 300 - 300 psig class 600 - 600 psig class 900 - 900 psig class 1500 - 1500 psig

22.3 15.7

Dimensions for classes 900 and 1500 are identical up to 2 ½" size!

28.4 19 8 25.4

* Other dimensions are available on request. Please contact COMECO!

YPFSA - G4.G5.G6.G7.G8'/8".G9.G10.G14

Code Feature or option

Code values

G4

Probe diameter 'd' [mm]

3, 4.5, 5, 6, 8, 10

G5

Insertion diameter 'F1' [mm]

13…21 (see table above) (1)

G6

Shank length 'U' [mm]

50…1000 (2) (see table above) (1)

G7

Extension length 'T' [mm]

0…100

G8'

Flange nominal size

50 - 1/2", 75 - 3/4", 100 - 1", 125 - 1¼", 150 - 1½", 200 - 2", Z - other (specify!) (2)

G8"

Flange nominal pressure (class)

150 - 10 bar (150 psig), 300 - 20 bar (300 psig), 600 - 40 bar (600 psig)

(1)

U9 - 3/8" NPT, U10 - 1/2" NPT, U11 - 3/4" NPT, Z - other (specify!) (2)

G9

Probe thread 'N'

G10

Material

M1 - 1.4301, M2 - 1.4541, M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)

G14

Flange face

A - flat (FF), B - raised (RF), D - groove, F - recess, G - O-ring recess, H - O-ring groove

(1)

Applicable for the selected probe diameter 'd' (2) Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code


accessories Flanged Welded Thermowell YPFW DIN-FLANGED WELDED THERMOWELL

YPFWD

DIMENSIONS * N

H [mm]

M14x1.5, G3/8”

15

18

M18x1.5

20

24

M20x1.5, G1/2"

20

26

M27x2, G3/4"

25

32

Material - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes

F2 [mm]

F1 x s [mm] 10x1.5, 10.2x2 (⅛"), 12x1.5, 13.5x2.35 (¼"), 14x2 10x1.5, 10.2x2 (⅛"), 12x1.5, 13.5x2.35, 14x2 (¼") 16x2, 17.2x2.35, 18x2, 20x2, 21.3x2.6 (½")

INSERTION LENGTH

Probe diameter: d < d1 or (F1- 2s) Probe thread: G = N Probe length (incl. thread): n = 0.98 * L - e (fixed) or n ≈ L - e (spring-loaded) Maximum temperature: 850 °C Maximum pressure: 25 bar (s = 1.5) or 40 bar (s ≥ 2)

F1 [mm]

U [mm]

≤ 12

max. 500

13...14

max. 1000

16...18

max. 1500

18...20

max. 2000

≥ 20

max. 2500

FLANGE DIMENSIONS *

L = U + b + H (flat face) or L = U + b + H + 2 (raised face)

Ordering code

NOMINAL SIZE

D [mm]

k [mm]

DN10 DN15 DN20 DN25 DN32 DN40 DN50

90 95 105 115 140 150 165

60 65 75 85 100 110 125

b d2 [mm] [mm]

bolts

Flange type: DIN 2527 or EN DIN 1092-1

14 14

4 x M12

16 18

Maximum pressure: PN10...PN40

18

4 x M16

(to fit thermowell specifications)

20

* Other dimensions are available on request. Please contact COMECO!

YPFWD - G4.G6.G8.G9.G10.G14

Code Feature or option

Code values

G4

Tube diameter 'F1' [mm]

10, 10.2 (2), 12, 13.5 (2), 14, 16, 17.2, 18, 20, 21.3

G6

Length 'U' [mm]

50…2500 (see table above) (1)

G8

Flange nominal size

DN10 (2), DN15, DN20, DN25, DN32, DN40, DN50, Z - other (specify!) (2)

G9

Probe thread 'N' (1)

U1 - M18x1.5, U2 - M20x1.5, U3 - G3/8", U4 - G1/2", U5 - M27x2, U6 - G3/4", U8 - M14x1.5, Z - other (specify!) (2)

G10

Material

M1 - 1.4301, M2 - 1.4541 (2), M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)

G14

Flange face

A - flat (FF), B - raised (RF), D - groove, F - recess, G - O-ring recess, H - O-ring groove

(1)

COMECO reserves the right of changing specifications without prior notice!

Applicable for the selected tube diameter 'F1' (2) Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


accessories

ANSI-FLANGED WELDED THERMOWELL

YPFWA

DIMENSIONS *

Material - stainless steel (see Appendix - Sheath materials) Application - with temperature gauges and TS probes

N

H [mm]

F2 [mm]

F1 x s [mm]

3/8” NPT

20

18

10x1.5, 10.2x2 (⅛"), 12x1.5, 13.5x2.35 (¼"), 14x2

1/2" NPT

25

26

10x1.5, 10.2x2 (⅛"), 12x1.5, 13.5x2.35, 14x2 (¼")

3/4" NPT

30

32

16x2, 17.2x2.35, 18x2, 20x2, 21.3x2.6 (½")

INSERTION LENGTH

Probe diameter: d < d1 or (F1- 2s) Probe thread: G = N Probe length (incl. thread): n = 0.98 * L - e + 0.4 * H (fixed) or n ≈ L - e + 0.4 * H (spring-loaded) Maximum temperature: 850 °C Maximum pressure: 25 bar (s = 1.5) or 40 bar (s ≥ 2)

F1 [mm]

U [mm]

≤ 12

max. 500

13...14

max. 1000

16...18

max. 1500

18...20

max. 2000

≥ 20

max. 2500

FLANGE DIMENSIONS [mm] * SIZE class ½"

¾"

1"

1 ¼"

1 ½"

L = U + b + H (flat face) or L = U + RF + b + H (raised face)

2"

150 300 600 150 300 600 150 300 600 150 300 600 150 300 600 150 300 600

D

k

b

88.9

60.5

95.2

66.5

98.6

69.8

9.7 12.7 14.2 11.2 14.2 15.7 12.7 16 17.5 14.2 18 20.6 16 19 22.3 17.5 20.8 25.4

117.3

82.5

108

79.2

124

88.9

117.3 133.4

98.6

127 155.4 114.3 152.4 120.6 165.1

127

RF

d2

holes

1.5 6.3

15.7 Flange type:

1.5 6.3 1.5 6.3 1.5 6.3 1.5 6.3 1.5

19

4

15.7

Maximum pressure:

19

class 150 - 150 psig class 300 - 300 psig class 600 - 600 psig

15.7 19 15.7

ANSI B16.5

4

(to fit thermowell specifications)

22.3 19

6.3

8

* Other dimensions are available on request. Please contact COMECO!

YPFWA - G4.G6.G8'/8".G9.G10.G14

Code Feature or option

(1) (2)

Code values

G4

Tube diameters 'F1' [mm]

10, 10.2 (2), 12, 13.5 (2), 14, 16, 17.2, 18, 20, 21.3

G6

Length 'U' [mm]

50…2500 (see table above) (1)

G8'

Flange nominal size

50 - ½", 75 - ¾", 100 - 1", 125 - 1¼", 150 - 1½", 200 - 2", Z - other (specify!) (2)

G8"

Flange nominal pressure (class)

150 - 10 bar (150 psig), 300 - 20 bar (300 psig), 600 - 40 bar (600 psig)

G9

Probe thread 'N' (1)

U9 - 3/8" NPT, U10 - 1/2" NPT, U11 - 3/4" NPT, Z - other (specify!) (2)

G10

Material

M1 - 1.4301, M2 - 1.4541 (2), M3 - 1.4571 (2), M9 - 1.4404 or 1.4435, Z - other (specify!) (2)

G14

Flange face

A - flat (FF), B - raised (RF), D - groove, F - recess, G - O-ring recess, H - O-ring groove

Applicable for the selected tube diameter 'F1' Contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Ordering code


accessories Ceramic Protection Tubes YAC

CERAMIC PROTECTION TUBE

YAC MATERIAL

Material - alumina ceramics (see Appendix - Sheath materials) Application - T/C protection in gaseous chemical media

Maximum Temperature

CERAMIC PROTECTION TUBE (C2)

C 710

1600 °C

DIMENSIONS * F1 [mm]

d1 [mm]

Fitting Type

6 8 10 15 18 20 24 32

4.5 6 7 10 12 15 17 24

1, 5, 9 1, 5, 9 1, 5, 9 1, 5, 9 2, 5, 10 2, 6, 10 3, 6, 11 4, 7, 12

L [mm] 100÷1000

100÷2000

PROPERTIES Chemical Composition Flexural Strength

L ≈ n + m - 30

Thermal Shock Resist

good

Thermal Conductivity

20 W/m.K

Thermal Expansion

8.10-6 K-1 (0-1000 °C)

Porosity

0%

Electrical Resitivity

CERAMIC PROTECTION TUBE (C3)

C 799

1700 °C

≥ 95% Al2O3 280 MPa

6 8 10 15 18 20 24 32

4.5 6 7 10 12 15 17 24

12 > 10 Ω.m (25°C)

1, 5, 9 1, 5, 9 1, 5, 9 1, 5, 9 2, 5, 10 2, 6, 10 3, 6, 11 4, 7, 12

100÷1000

100÷2000

PROPERTIES Chemical Composition Flexural Strength

L ≈ n + m - 30

> 99.7% Al2O3 360 MPa

Thermal Shock Resist

good

Thermal Conductivity

28 W/m.K

Thermal Expansion

9.10 K (0-1200°C)

Porosity

0%

Electrical Resitivity

> 1012 Ω.m (25°C)

-6

-1

FITTING

Length 'm' [mm]

80 or 150

(1)

80 or 150 (1)

80 or 150

(1)

(1)

Material

stainless steel

stainless steel

stainless steel

TYPE

CONNECTION

1

½"

2

¾"

3

1"

4

1 ¼"

5

½"

6

¾"

7

1"

8

1 ¼"

9

½" x ½"

10

¾" x ½"

11

1" x ¾"

12

1 ¼" x ¾"

For tube length L ≥ 1000 mm

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org

COMECO reserves the right of changing specifications without prior notice!

* Other dimensions are available on request. Please contact COMECO!


accessories

Ordering code

YAC - G10.G5.G6.G9'G9"

Code Feature or option Sheath material

(2)

Code values C2 - Alumina 95% (C 710), C3 - Alumina 99% (C 799)

G5

Outer diameter 'OD' [mm]

from tables overleaf

G6

Length 'L' [mm]

from tables overleaf

G9'

Fitting type

X - none, 1 - type 1, 2 - type 2, 3 - type 3, 4 - type 4, 5 - type 5, 6 - type 6, 7 - type 7, 8 - type 8, 9 - type 9, 10 - type 10, 11 - type 11, 12 - type 12, Z - other (specify!)

G9"

Fitting thread

G - parallel pipe threads, N - NPT threads, X - none *, Z - other (specify!)

Always ask for availability! * contact COMECO!

COMECO reserves the right of changing specifications without prior notice!

(2)

G10

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org


accessories Metal Protection Tubes YAM YAM

Material - metals and metal alloys (see Appendix - Sheath materials) Application - temperature probe protection in athmospheres and baths

MATERIAL

Carbon Steel

WELDED PROTECTION TUBE (W)

1.4301 (AISI 304)

PROPERTIES Max. temperature Composition Thermal conductivity Composition

550 °C Mn0.8Si0.4C0.2 76 W/m.K Cr18Ni9Mn2Si1

Max. temperature

450 °C

Thermal conductivity 15 W/m.K 1.4404 (AISI 316L) 1.4571 (AISI 316Ti) 1.4841 (AISI 310)

1.4762 (AISI 446)

L

F1

S

G

Titanium

100...500

10

1

M10

Kanthal  other

200...2000

~27

~3

¾"

Atmospheres: oxidizing Baths: food products, mild acids and alkalis, petroleum

Max. temperature

1150 °C

Composition

Cr25Al2Si1

Atmospheres: oxidizing, sulpurous (NOT suitable for carburizing!) Baths: molten Pb, Sn, babbitt, neutral salt baths

1100 °C 2.4816 Composition Cr16Ni72Mn1 (Inconel 600) Thermal conductivity 14 W/m.K

200...2000

21~22

~2

½"

Monel  (Alloy 400)

Max. temperature

550 °C

Composition

Ni63Cu34Mn2

Thermal conductivity 22 W/m.K 1050 °C 2.4602 Composition Cr21Mo14Wo3Co (Hastelloy C) Thermal conductivity 10 W/m.K Max. temperature

Hastelloy X

Max. temperature

1200 °C

Composition

Cr22Mo10Co2Wo

Thermal conductivity 10 W/m.K

Kanthal A

Max. temperature

1250 °C

Composition

Cr22Al6

Thermal conductivity 29 W/m.K 3.7035 Titanium Grade 2

BORED PROTECTION TUBE (B)

DIMENSIONS: * [mm]

L

F1

d1

G

Titanium

100...500

14

7

M10

other

200...800

~25

9

½"

Atmospheres: oxidizing, cryogenic Baths: food products, mild acids and alkalis, petroleum

850 °C Cr17Ni11Mo2 15 W/m.K 850 °C Cr17Ni13Mo2Ti 16 W/m.K 1150 °C Cr25Ni21Mn2 16 W/m.K

Thermal conductivity 14 W/m.K

[mm]

Atmospheres: non-oxidizing Baths: petroleum, molten Zn, Mg, Pb, Sn, babbitt

Max. temperature Composition Thermal conductivity Max. temperature Composition Thermal conductivity Max. temperature Composition Thermal conductivity

Max. temperature

DIMENSIONS: *

APPLICATION

Max. temperature

600 °C

Composition

99.2% Ti

Thermal conductivity 16 W/m.K

Atmospheres: oxidizing Baths: food products, petroleum increased resistance to acids Atmospheres: oxidizing, carburizing, nitriding Baths: general applications

Atmospheres: oxidizing, nitriding, mild sulphur and carburizing (up to 550 °C) Baths: salt (cyanide) baths Atmospheres: non-oxidizing Baths: salt waters, alkalis, and acids, but NOT oxidizing acids like nitric or nitrous. Atmospheres: oxidizing, carburizing, nitriding, chlorine Baths: acids, chlorides, brine and many aggressive chemicals Atmospheres: oxidizing, carburizing, sulpurous, nitriding, chlorine Baths: general applications Atmospheres: oxidizing, carburizing, sulpurous, nitriding, ammonia Baths: molten Cu, Zn, Mg Atmospheres: high aggressive gases Baths: high aggressive solvents

Carbon Steel

see above

see above

1.4301 (AISI 304)

see above

see above

1.4404 (AISI 316L)

see above

see above

1.4571 (AISI 316Ti)

see above

see above

3.7035 Titanium Grade 2

see above

see above

Cast Iron GG-30 (ATSM A48)

Pure Iron

Max. temperature

700 °C

Composition

C3Si2Mn

Thermal conductivity 45 W/m.K Max. temperature

1300 °C

Composition

Fe

Atmospheres: oxidizing Baths: sulphur and caustic solutions some molten non-ferrous metals Baths: salt, cyanide, chloride

Thermal conductivity 80 W/m.K * Other dimensions are available on request. Please contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org

COMECO reserves the right of changing specifications without prior notice!

METAL PROTECTION TUBE


accessories

Ordering code

YAM - G6.G9.G10

Code Feature or option G6

100…2000 (see tables overleaf)

Length 'L' [mm]

G9

Connection thread 'G'

G10

Material (see tables overleaf)

(1)

(2)

(2)

(1)

G - parallel pipe threads, N - NPT threads, X - none *, Z - other (specify!) M1 - 1.4301, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404(1.4435), M12 - cast iron, M13 - carbon steel, M14 - Kanthal® A, M18 - 2.4602 (Hastelloy C), M19 - Hastelloy X, M20 - Titanium alloy, M21 - Monel®, * Z - other (specify!)

Applicable for the selected design and material Always ask for availability! * contact COMECO!

COMECO reserves the right of changing specifications without prior notice!

(1)

Code values W - welded, B - bored

Design

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org


accessories Ceramic Protection Tubes for Molten Metals YACM YACM

Material - silicon/carbon/alumina ceramics (see Appendix - Sheath materials) Application - T/C protection in molten metals and gaseous media

MATERIAL

Maximum Temperature

DIMENSIONS * F1 [mm]

d1 [mm]

Fitting Type

L [mm]

22

16

2, 3, 6, 11

230, 305, 460, 610, 760, 915, 1220

UCAR LT1  PROTECTION TUBE (C4) UCAR

LT1

1650 °C

PROPERTIES

Applicable metals:

L ≈ n + m - 30

Copper, Brass - up to 1150 °C Steel - up to 1375 °C (peak to 1735 °C) Zink, Lead, Tin, Silver, other metals

Chemical Composition

Non-applicable metals: Aluminum

SILICON CARBIDE PROTECTION TUBE (C5) SILICON CARBIDE

1380 °C

Flexural Strength Thermal Shock Resist

700 ∆T°C

Thermal Conductivity

29.4 W/m.K

Thermal Expansion

9.10 K (0-1000 °C)

Non-applicable metals: ferrous metals L ≈ n + m - 30

Porosity

0% conductive

20

10

2, 6, 10

25

12

3, 6, 11

30

16

4, 7, 12

40

20

8

HEXOLOY PROTECTION TUBE (C6) 1650 °C

85% SiC + 15% SiO2 250 MPa

Thermal Shock Resist

~500 ∆T°C

Thermal Conductivity

45 W/m.K

Thermal Expansion

5.10-6 K-1 (0-1200 °C)

Porosity

0.1 %

9.5

6.5

16 19 25 32 38

9.5 13 13 19 25

Non-applicable metals: ferrous metals

(Syalon 050)

150÷1370

Chemical Composition

98% SiC

Flexural Strength

380 MPa

Thermal Shock Resist

890 MPa @ 450 ∆T°C

Thermal Conductivity

30 W/m.K

Thermal Expansion

4.10-6 K-1 (0-1200 °C)

Porosity

0.6 %

Electrical Resitivity Syalon 101

107 Ω.m (25°C) 1, 5, 9 2, 5, 10 2, 6, 10 3, 6, 11 4, 7, 12 8

PROPERTIES

Aluminum, Copper, Brass, Zink, Lead, Tin, other non-ferrous metals

SYALON PROTECTION TUBE (C7)

200÷2000

Flexural Strength

Applicable metals:

L ≈ n + m - 30

200÷1000

Chemical Composition

Electrical Resitivity

SE

-1

PROPERTIES

Aluminum, Copper, Brass, Zink, Lead, Tin, other non-ferrous metals

HEXOLOY

-6

Electrical Resitivity

Applicable metals:

77%Cr + 23% Al2O3 310 MPa

1200 °C (1400 °C)

12.5

6.5

16 22 28

9 12 16

7

10 Ω.m (25°C) 200÷1000 1, 5, 9 (no groove) 2, 5, 10 3, 6, 11 4, 7, 12

150÷2000

PROPERTIES Applicable metals:

Chemical Composition

90% Si3N4 + 6% Al2O3

Aluminum, Brass, Tin, Lead, Bismuth, Cadmium, Magnesium, Cast iron

Flexural Strength

760 MPa

Non-applicable metals: Copper, ferrous metals

L ≈ n + m - 30

Thermal Shock Resist

900 ∆T°C

Thermal Conductivity

28 W/m.K

Thermal Expansion

3.10 K (0-1200°C)

Porosity

0%

Electrical Resitivity

1010 Ω.m (25°C)

-6

-1

* Other dimensions are available on request. Please contact COMECO!

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org

COMECO reserves the right of changing specifications without prior notice!

CERAMIC PROTECTION TUBE


accessories FITTING

Length 'm' [mm]

80 or 150

80 or 150

80 or 150

(1)

(1)

(1)

stainless steel

stainless steel

stainless steel

TYPE

CONNECTION

1

½"

2

¾"

3

1"

4

1 ¼"

5

½"

6

¾"

7

1"

8

1 ¼"

9

½" x ½"

10

¾" x ½"

11

1" x ¾"

12

1 ¼" x ¾"

For tube length L ≥ 1000 mm

Ordering code

YACM - G10.G5.G6.G9'G9"

Code Feature or option

Code values

G10

Sheath material (2)

C4 - UCAR LT1, C5 - silicon carbide, C6 - Hexoloy, C7 - Syalon

G5

Outer diameter 'OD' [mm]

from tables overleaf

G6

Length 'L' [mm]

from tables overleaf

G9'

Fitting type

X - none, 1 - type 1, 2 - type 2, 3 - type 3, 4 - type 4, 5 - type 5, 6 - type 6, 7 - type 7, 8 - type 8, 9 - type 9, 10 - type 10, 11 - type 11, 12 - type 12, Z - other (specify!)

G9"

Fitting thread

G - parallel pipe threads, N - NPT threads, X - none *, Z - other (specify!)

Always ask for availability! * contact COMECO!

COMECO reserves the right of changing specifications without prior notice!

(2)

(1)

Material

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646524, fax: +359 32 634089, e-mail: export@comeco.org


accessories Interface Cables

Schematic

Interface

Application

side "A"

side "B"

K1

COMECO device

RS232 (PC)

Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v1.16 or higher

K2

COMECO device

RS232 (PC)

Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v1.16 or higher

K1U

COMECO device

IA250T

Configuration: TRB-B, TRBI-B Software: "TraCon" v2.0 or higher

K2U

COMECO device

IA250T

Configuration: TRB-C, TRBI-C, TRZ Software: "TraCon" v2.0 or higher

K3

COMECO device

RS232 (PC)

Configuration: TRY, old TRB-C Software: "TraCon" (1)

K3U

COMECO device

USB (PC)

Configuration: TRY Software: "TraCon" v2.0 or higher

K4

COMECO device

RS232 (PC)

Configuration: old TRB-B Software: "TraCon" (1)

K5

COMECO device

RS232 (PC)

Configuration: old TRB-B Software: "TraCon" (1)

K6

IA100 interface adapter

RS232 (PC)

Standard RS232 cable

K7

RS232

RS232 (PC)

Standard RS232 cable

K8

USB 2.0 standard

USB 2.0 standard

Standard USB cable

K9U

COMECO device

USB (PC)

Configuration and power supply: RHV, TSOJ Software: "TraCon" (1)

K10U

COMECO device with RS485

IA250N

Configuration: COMECO devices Software: "PolyMonitor"

K11U

COMECO device

USB (PC)

Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher

K12U

COMECO device

USB (PC)

Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v2.0 or higher

K13

OT801 serial printer

IA300

Configuration: IA300 data-logger Software: "InfoPrint"

K14

USB 2.0 standard

USB 2.0 standard

Standard USB cable

(1)

Contact COMECO

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Code


accessories

Code

Interface

Schematic

Application

side "A"

side "B"

K15U

COMECO device

USB (PC)

Configuration: old TRB-B Software: "TraCon" (1)

K16U

current loop

USB (PC)

Power supply: 15 VDC, max. 60 mA

COMECO device

RS232 (PC)

Configuration: TSOJ Software: "TraCon" (1)

K19U

COMECO device

USB (PC)

Configuration and power supply: TSOJ Software: "TraCon" (1)

KA1

COMECO device

K2, K2U, K5, K12U

Adapter – simulates K1, K1U, K4, K11U Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher

KIA

INOR device

RS232 (PC)

Configuration: TRSN-C (IPAQ-L) Software: "Ipro"

KIB

INOR device

RS232 (PC)

Configuration: TRSN-B (IPAQ-H) Software: "Ipro"

KIC

INOR device

RS232 (PC)

Configuration: TRP (ProfIPAQ) Software: "ProfiSoft"

KID

INOR device

RS232 (PC)

Configuration: TRSP (IPAQ-H/L+) Software: "Ipro"

DIN43650 4-pin (F)

DB-9 (F)

K19 *

USB-A (M)

COMECO reserves the right of changing specifications without prior notice!

DIN43650 4-pin (F)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


accessories Interface Cables

Schematic

Interface

Application

side "A"

side "B"

K1

COMECO device

RS232 (PC)

Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v1.16 or higher

K2

COMECO device

RS232 (PC)

Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v1.16 or higher

K1U

COMECO device

IA250T

Configuration: TRB-B, TRBI-B Software: "TraCon" v2.0 or higher

K2U

COMECO device

IA250T

Configuration: TRB-C, TRBI-C, TRZ Software: "TraCon" v2.0 or higher

K3

COMECO device

RS232 (PC)

Configuration: TRY, old TRB-C Software: "TraCon" (1)

K3U

COMECO device

USB (PC)

Configuration: TRY Software: "TraCon" v2.0 or higher

K4

COMECO device

RS232 (PC)

Configuration: old TRB-B Software: "TraCon" (1)

K5

COMECO device

RS232 (PC)

Configuration: old TRB-B Software: "TraCon" (1)

K6

IA100 interface adapter

RS232 (PC)

Standard RS232 cable

K7

RS232

RS232 (PC)

Standard RS232 cable

K8

USB 2.0 standard

USB 2.0 standard

Standard USB cable

K9U

COMECO device

USB (PC)

Configuration and power supply: RHV, TSOJ Software: "TraCon" (1)

K10U

COMECO device with RS485

IA250N

Configuration: COMECO devices Software: "PolyMonitor"

K11U

COMECO device

USB (PC)

Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher

K12U

COMECO device

USB (PC)

Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v2.0 or higher

K13

OT801 serial printer

IA300

Configuration: IA300 data-logger Software: "InfoPrint"

K14

USB 2.0 standard

USB 2.0 standard

Standard USB cable

(1)

Contact COMECO

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Code


accessories

Code

Interface

Schematic

Application

side "A"

side "B"

K15U

COMECO device

USB (PC)

Configuration: old TRB-B Software: "TraCon" (1)

K16U

current loop

USB (PC)

Power supply: 15 VDC, max. 60 mA

COMECO device

RS232 (PC)

Configuration: TSOJ Software: "TraCon" (1)

K19U

COMECO device

USB (PC)

Configuration and power supply: TSOJ Software: "TraCon" (1)

KA1

COMECO device

K2, K2U, K5, K12U

Adapter – simulates K1, K1U, K4, K11U Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher

KIA

INOR device

RS232 (PC)

Configuration: TRSN-C (IPAQ-L) Software: "Ipro"

KIB

INOR device

RS232 (PC)

Configuration: TRSN-B (IPAQ-H) Software: "Ipro"

KIC

INOR device

RS232 (PC)

Configuration: TRP (ProfIPAQ) Software: "ProfiSoft"

KID

INOR device

RS232 (PC)

Configuration: TRSP (IPAQ-H/L+) Software: "Ipro"

DIN43650 4-pin (F)

DB-9 (F)

K19 *

USB-A (M)

COMECO reserves the right of changing specifications without prior notice!

DIN43650 4-pin (F)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


accessories Interface Cables

Schematic

Interface

Application

side "A"

side "B"

K1

COMECO device

RS232 (PC)

Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v1.16 or higher

K2

COMECO device

RS232 (PC)

Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v1.16 or higher

K1U

COMECO device

IA250T

Configuration: TRB-B, TRBI-B Software: "TraCon" v2.0 or higher

K2U

COMECO device

IA250T

Configuration: TRB-C, TRBI-C, TRZ Software: "TraCon" v2.0 or higher

K3

COMECO device

RS232 (PC)

Configuration: TRY, old TRB-C Software: "TraCon" (1)

K3U

COMECO device

USB (PC)

Configuration: TRY Software: "TraCon" v2.0 or higher

K4

COMECO device

RS232 (PC)

Configuration: old TRB-B Software: "TraCon" (1)

K5

COMECO device

RS232 (PC)

Configuration: old TRB-B Software: "TraCon" (1)

K6

IA100 interface adapter

RS232 (PC)

Standard RS232 cable

K7

RS232

RS232 (PC)

Standard RS232 cable

K8

USB 2.0 standard

USB 2.0 standard

Standard USB cable

K9U

COMECO device

USB (PC)

Configuration and power supply: RHV, TSOJ Software: "TraCon" (1)

K10U

COMECO device with RS485

IA250N

Configuration: COMECO devices Software: "PolyMonitor"

K11U

COMECO device

USB (PC)

Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher

K12U

COMECO device

USB (PC)

Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v2.0 or higher

K13

OT801 serial printer

IA300

Configuration: IA300 data-logger Software: "InfoPrint"

K14

USB 2.0 standard

USB 2.0 standard

Standard USB cable

(1)

Contact COMECO

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Code


accessories

Code

Interface

Schematic

Application

side "A"

side "B"

K15U

COMECO device

USB (PC)

Configuration: old TRB-B Software: "TraCon" (1)

K16U

current loop

USB (PC)

Power supply: 15 VDC, max. 60 mA

COMECO device

RS232 (PC)

Configuration: TSOJ Software: "TraCon" (1)

K19U

COMECO device

USB (PC)

Configuration and power supply: TSOJ Software: "TraCon" (1)

KA1

COMECO device

K2, K2U, K5, K12U

Adapter – simulates K1, K1U, K4, K11U Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher

KIA

INOR device

RS232 (PC)

Configuration: TRSN-C (IPAQ-L) Software: "Ipro"

KIB

INOR device

RS232 (PC)

Configuration: TRSN-B (IPAQ-H) Software: "Ipro"

KIC

INOR device

RS232 (PC)

Configuration: TRP (ProfIPAQ) Software: "ProfiSoft"

KID

INOR device

RS232 (PC)

Configuration: TRSP (IPAQ-H/L+) Software: "Ipro"

DIN43650 4-pin (F)

DB-9 (F)

K19 *

USB-A (M)

COMECO reserves the right of changing specifications without prior notice!

DIN43650 4-pin (F)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


accessories Interface Cables

Schematic

Interface

Application

side "A"

side "B"

K1

COMECO device

RS232 (PC)

Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v1.16 or higher

K2

COMECO device

RS232 (PC)

Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v1.16 or higher

K1U

COMECO device

IA250T

Configuration: TRB-B, TRBI-B Software: "TraCon" v2.0 or higher

K2U

COMECO device

IA250T

Configuration: TRB-C, TRBI-C, TRZ Software: "TraCon" v2.0 or higher

K3

COMECO device

RS232 (PC)

Configuration: TRY, old TRB-C Software: "TraCon" (1)

K3U

COMECO device

USB (PC)

Configuration: TRY Software: "TraCon" v2.0 or higher

K4

COMECO device

RS232 (PC)

Configuration: old TRB-B Software: "TraCon" (1)

K5

COMECO device

RS232 (PC)

Configuration: old TRB-B Software: "TraCon" (1)

K6

IA100 interface adapter

RS232 (PC)

Standard RS232 cable

K7

RS232

RS232 (PC)

Standard RS232 cable

K8

USB 2.0 standard

USB 2.0 standard

Standard USB cable

K9U

COMECO device

USB (PC)

Configuration and power supply: RHV, TSOJ Software: "TraCon" (1)

K10U

COMECO device with RS485

IA250N

Configuration: COMECO devices Software: "PolyMonitor"

K11U

COMECO device

USB (PC)

Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher

K12U

COMECO device

USB (PC)

Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v2.0 or higher

K13

OT801 serial printer

IA300

Configuration: IA300 data-logger Software: "InfoPrint"

K14

USB 2.0 standard

USB 2.0 standard

Standard USB cable

(1)

Contact COMECO

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Code


accessories

Code

Interface

Schematic

Application

side "A"

side "B"

K15U

COMECO device

USB (PC)

Configuration: old TRB-B Software: "TraCon" (1)

K16U

current loop

USB (PC)

Power supply: 15 VDC, max. 60 mA

COMECO device

RS232 (PC)

Configuration: TSOJ Software: "TraCon" (1)

K19U

COMECO device

USB (PC)

Configuration and power supply: TSOJ Software: "TraCon" (1)

KA1

COMECO device

K2, K2U, K5, K12U

Adapter – simulates K1, K1U, K4, K11U Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher

KIA

INOR device

RS232 (PC)

Configuration: TRSN-C (IPAQ-L) Software: "Ipro"

KIB

INOR device

RS232 (PC)

Configuration: TRSN-B (IPAQ-H) Software: "Ipro"

KIC

INOR device

RS232 (PC)

Configuration: TRP (ProfIPAQ) Software: "ProfiSoft"

KID

INOR device

RS232 (PC)

Configuration: TRSP (IPAQ-H/L+) Software: "Ipro"

DIN43650 4-pin (F)

DB-9 (F)

K19 *

USB-A (M)

COMECO reserves the right of changing specifications without prior notice!

DIN43650 4-pin (F)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


accessories Interface Cables

Schematic

Interface

Application

side "A"

side "B"

K1

COMECO device

RS232 (PC)

Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v1.16 or higher

K2

COMECO device

RS232 (PC)

Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v1.16 or higher

K1U

COMECO device

IA250T

Configuration: TRB-B, TRBI-B Software: "TraCon" v2.0 or higher

K2U

COMECO device

IA250T

Configuration: TRB-C, TRBI-C, TRZ Software: "TraCon" v2.0 or higher

K3

COMECO device

RS232 (PC)

Configuration: TRY, old TRB-C Software: "TraCon" (1)

K3U

COMECO device

USB (PC)

Configuration: TRY Software: "TraCon" v2.0 or higher

K4

COMECO device

RS232 (PC)

Configuration: old TRB-B Software: "TraCon" (1)

K5

COMECO device

RS232 (PC)

Configuration: old TRB-B Software: "TraCon" (1)

K6

IA100 interface adapter

RS232 (PC)

Standard RS232 cable

K7

RS232

RS232 (PC)

Standard RS232 cable

K8

USB 2.0 standard

USB 2.0 standard

Standard USB cable

K9U

COMECO device

USB (PC)

Configuration and power supply: RHV, TSOJ Software: "TraCon" (1)

K10U

COMECO device with RS485

IA250N

Configuration: COMECO devices Software: "PolyMonitor"

K11U

COMECO device

USB (PC)

Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher

K12U

COMECO device

USB (PC)

Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v2.0 or higher

K13

OT801 serial printer

IA300

Configuration: IA300 data-logger Software: "InfoPrint"

K14

USB 2.0 standard

USB 2.0 standard

Standard USB cable

(1)

Contact COMECO

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Code


accessories

Code

Interface

Schematic

Application

side "A"

side "B"

K15U

COMECO device

USB (PC)

Configuration: old TRB-B Software: "TraCon" (1)

K16U

current loop

USB (PC)

Power supply: 15 VDC, max. 60 mA

COMECO device

RS232 (PC)

Configuration: TSOJ Software: "TraCon" (1)

K19U

COMECO device

USB (PC)

Configuration and power supply: TSOJ Software: "TraCon" (1)

KA1

COMECO device

K2, K2U, K5, K12U

Adapter – simulates K1, K1U, K4, K11U Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher

KIA

INOR device

RS232 (PC)

Configuration: TRSN-C (IPAQ-L) Software: "Ipro"

KIB

INOR device

RS232 (PC)

Configuration: TRSN-B (IPAQ-H) Software: "Ipro"

KIC

INOR device

RS232 (PC)

Configuration: TRP (ProfIPAQ) Software: "ProfiSoft"

KID

INOR device

RS232 (PC)

Configuration: TRSP (IPAQ-H/L+) Software: "Ipro"

DIN43650 4-pin (F)

DB-9 (F)

K19 *

USB-A (M)

COMECO reserves the right of changing specifications without prior notice!

DIN43650 4-pin (F)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


accessories Interface Cables

Schematic

Interface

Application

side "A"

side "B"

K1

COMECO device

RS232 (PC)

Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v1.16 or higher

K2

COMECO device

RS232 (PC)

Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v1.16 or higher

K1U

COMECO device

IA250T

Configuration: TRB-B, TRBI-B Software: "TraCon" v2.0 or higher

K2U

COMECO device

IA250T

Configuration: TRB-C, TRBI-C, TRZ Software: "TraCon" v2.0 or higher

K3

COMECO device

RS232 (PC)

Configuration: TRY, old TRB-C Software: "TraCon" (1)

K3U

COMECO device

USB (PC)

Configuration: TRY Software: "TraCon" v2.0 or higher

K4

COMECO device

RS232 (PC)

Configuration: old TRB-B Software: "TraCon" (1)

K5

COMECO device

RS232 (PC)

Configuration: old TRB-B Software: "TraCon" (1)

K6

IA100 interface adapter

RS232 (PC)

Standard RS232 cable

K7

RS232

RS232 (PC)

Standard RS232 cable

K8

USB 2.0 standard

USB 2.0 standard

Standard USB cable

K9U

COMECO device

USB (PC)

Configuration and power supply: RHV, TSOJ Software: "TraCon" (1)

K10U

COMECO device with RS485

IA250N

Configuration: COMECO devices Software: "PolyMonitor"

K11U

COMECO device

USB (PC)

Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher

K12U

COMECO device

USB (PC)

Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v2.0 or higher

K13

OT801 serial printer

IA300

Configuration: IA300 data-logger Software: "InfoPrint"

K14

USB 2.0 standard

USB 2.0 standard

Standard USB cable

(1)

Contact COMECO

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Code


accessories

Code

Interface

Schematic

Application

side "A"

side "B"

K15U

COMECO device

USB (PC)

Configuration: old TRB-B Software: "TraCon" (1)

K16U

current loop

USB (PC)

Power supply: 15 VDC, max. 60 mA

COMECO device

RS232 (PC)

Configuration: TSOJ Software: "TraCon" (1)

K19U

COMECO device

USB (PC)

Configuration and power supply: TSOJ Software: "TraCon" (1)

KA1

COMECO device

K2, K2U, K5, K12U

Adapter – simulates K1, K1U, K4, K11U Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher

KIA

INOR device

RS232 (PC)

Configuration: TRSN-C (IPAQ-L) Software: "Ipro"

KIB

INOR device

RS232 (PC)

Configuration: TRSN-B (IPAQ-H) Software: "Ipro"

KIC

INOR device

RS232 (PC)

Configuration: TRP (ProfIPAQ) Software: "ProfiSoft"

KID

INOR device

RS232 (PC)

Configuration: TRSP (IPAQ-H/L+) Software: "Ipro"

DIN43650 4-pin (F)

DB-9 (F)

K19 *

USB-A (M)

COMECO reserves the right of changing specifications without prior notice!

DIN43650 4-pin (F)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


accessories Interface Cables

Schematic

Interface

Application

side "A"

side "B"

K1

COMECO device

RS232 (PC)

Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v1.16 or higher

K2

COMECO device

RS232 (PC)

Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v1.16 or higher

K1U

COMECO device

IA250T

Configuration: TRB-B, TRBI-B Software: "TraCon" v2.0 or higher

K2U

COMECO device

IA250T

Configuration: TRB-C, TRBI-C, TRZ Software: "TraCon" v2.0 or higher

K3

COMECO device

RS232 (PC)

Configuration: TRY, old TRB-C Software: "TraCon" (1)

K3U

COMECO device

USB (PC)

Configuration: TRY Software: "TraCon" v2.0 or higher

K4

COMECO device

RS232 (PC)

Configuration: old TRB-B Software: "TraCon" (1)

K5

COMECO device

RS232 (PC)

Configuration: old TRB-B Software: "TraCon" (1)

K6

IA100 interface adapter

RS232 (PC)

Standard RS232 cable

K7

RS232

RS232 (PC)

Standard RS232 cable

K8

USB 2.0 standard

USB 2.0 standard

Standard USB cable

K9U

COMECO device

USB (PC)

Configuration and power supply: RHV, TSOJ Software: "TraCon" (1)

K10U

COMECO device with RS485

IA250N

Configuration: COMECO devices Software: "PolyMonitor"

K11U

COMECO device

USB (PC)

Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher

K12U

COMECO device

USB (PC)

Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v2.0 or higher

K13

OT801 serial printer

IA300

Configuration: IA300 data-logger Software: "InfoPrint"

K14

USB 2.0 standard

USB 2.0 standard

Standard USB cable

(1)

Contact COMECO

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Code


accessories

Code

Interface

Schematic

Application

side "A"

side "B"

K15U

COMECO device

USB (PC)

Configuration: old TRB-B Software: "TraCon" (1)

K16U

current loop

USB (PC)

Power supply: 15 VDC, max. 60 mA

COMECO device

RS232 (PC)

Configuration: TSOJ Software: "TraCon" (1)

K19U

COMECO device

USB (PC)

Configuration and power supply: TSOJ Software: "TraCon" (1)

KA1

COMECO device

K2, K2U, K5, K12U

Adapter – simulates K1, K1U, K4, K11U Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher

KIA

INOR device

RS232 (PC)

Configuration: TRSN-C (IPAQ-L) Software: "Ipro"

KIB

INOR device

RS232 (PC)

Configuration: TRSN-B (IPAQ-H) Software: "Ipro"

KIC

INOR device

RS232 (PC)

Configuration: TRP (ProfIPAQ) Software: "ProfiSoft"

KID

INOR device

RS232 (PC)

Configuration: TRSP (IPAQ-H/L+) Software: "Ipro"

DIN43650 4-pin (F)

DB-9 (F)

K19 *

USB-A (M)

COMECO reserves the right of changing specifications without prior notice!

DIN43650 4-pin (F)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


accessories Interface Cables

Schematic

Interface

Application

side "A"

side "B"

K1

COMECO device

RS232 (PC)

Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v1.16 or higher

K2

COMECO device

RS232 (PC)

Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v1.16 or higher

K1U

COMECO device

IA250T

Configuration: TRB-B, TRBI-B Software: "TraCon" v2.0 or higher

K2U

COMECO device

IA250T

Configuration: TRB-C, TRBI-C, TRZ Software: "TraCon" v2.0 or higher

K3

COMECO device

RS232 (PC)

Configuration: TRY, old TRB-C Software: "TraCon" (1)

K3U

COMECO device

USB (PC)

Configuration: TRY Software: "TraCon" v2.0 or higher

K4

COMECO device

RS232 (PC)

Configuration: old TRB-B Software: "TraCon" (1)

K5

COMECO device

RS232 (PC)

Configuration: old TRB-B Software: "TraCon" (1)

K6

IA100 interface adapter

RS232 (PC)

Standard RS232 cable

K7

RS232

RS232 (PC)

Standard RS232 cable

K8

USB 2.0 standard

USB 2.0 standard

Standard USB cable

K9U

COMECO device

USB (PC)

Configuration and power supply: RHV, TSOJ Software: "TraCon" (1)

K10U

COMECO device with RS485

IA250N

Configuration: COMECO devices Software: "PolyMonitor"

K11U

COMECO device

USB (PC)

Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher

K12U

COMECO device

USB (PC)

Configuration: TRB(I)-C, TRC-C, TRZ Software: "TraCon" v2.0 or higher

K13

OT801 serial printer

IA300

Configuration: IA300 data-logger Software: "InfoPrint"

K14

USB 2.0 standard

USB 2.0 standard

Standard USB cable

(1)

Contact COMECO

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,

COMECO reserves the right of changing specifications without prior notice!

Code


accessories

Code

Interface

Schematic

Application

side "A"

side "B"

K15U

COMECO device

USB (PC)

Configuration: old TRB-B Software: "TraCon" (1)

K16U

current loop

USB (PC)

Power supply: 15 VDC, max. 60 mA

COMECO device

RS232 (PC)

Configuration: TSOJ Software: "TraCon" (1)

K19U

COMECO device

USB (PC)

Configuration and power supply: TSOJ Software: "TraCon" (1)

KA1

COMECO device

K2, K2U, K5, K12U

Adapter – simulates K1, K1U, K4, K11U Configuration: TRB(I)-B, TRC-B, TROJ Software: "TraCon" v2.0 or higher

KIA

INOR device

RS232 (PC)

Configuration: TRSN-C (IPAQ-L) Software: "Ipro"

KIB

INOR device

RS232 (PC)

Configuration: TRSN-B (IPAQ-H) Software: "Ipro"

KIC

INOR device

RS232 (PC)

Configuration: TRP (ProfIPAQ) Software: "ProfiSoft"

KID

INOR device

RS232 (PC)

Configuration: TRSP (IPAQ-H/L+) Software: "Ipro"

DIN43650 4-pin (F)

DB-9 (F)

K19 *

USB-A (M)

COMECO reserves the right of changing specifications without prior notice!

DIN43650 4-pin (F)

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,


accessories Tag Label TL TAG LABEL

TL

Material - aluminum or stainless steel (see Appendix - Sheath materials) Application - with TS and LC probes

SPECIFICATIONS * Area 2 [cm ]

Dimensions [mm]

Width [mm]

Font Size

Rows

Graphics

2...50

min. 10 (X/Y axis)

0.5...1.5

min. 8 pt

1...4

vector only

Technology: laser cut and engraved

* Exact shape, dimensions, design, and text according to customer specs!

(example)

Ordering code

TL - G1.G4.G6.G10

Code Feature or option

Code values

Number of rows

1, 2, 3, 4

G4

Area [cm2]

2‌50

G6

Width

5 - 0.5 mm, 10 - 1.0 mm, 15 - 1.5 mm

G10

Material

AL - aluminum, M1 - 1.4301, M9 - 1.4404 (1.4435)

COMECO reserves the right of changing specifications without prior notice!

G1

Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,





Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.