HTM ACTUATORS & VALVE AUTOMATION PACKAGE
HTM VALVES
HAITIMA CORPORATION
PNEUMATIC ACTUATOR
Pneumatic Actuator - Operating Conditions 1. Pressure Ranges 40 psig to 100 psig 3 bar to 8 bar
2. Temperature Ranges *Std.(NBR O-rings): -20℃(-4°F) to +80℃(+176°F) F) to +80℃(+176゜ F) *Lower Temp. (Silicone O-rings): -40℃(-40゜ *High Temp. (Viton O-rings): -15℃(+5゜ F) to +150℃(+300゜ F) Note: Special grease is required for low and high temperature service condition.
3. Wide Range Available The actuator range consists of 14 sizes, with torques from 9.7N.m(88in.lbs) to 4,122N.m (37,763in.lbs) at 6 bar (90 psig) air supply.
4. Operating Media Filtered dry or lubricated air for non-corrosive gas, water or light hydraulic oil. The maximum particle size must not exceed 30 microns.
5. Stroke Adjustment 0°and 90° with standard adjustment ± 5°.
6. Lubrication All moving parts are factory lubricated for entire life cycle of actuator.
7. Construction Twin piston rack and pinion actuator design, suitable for indoor and outdoor installation.
8. Connections Bottom drilling complies with ISO 5211/DIN 3337 to match valve. Interface for solenoid valve, shaft top end and top drilling for assembling accessories are in accordance with VDI/VDE-3845, NAMUR standard.
9. Inspection Every actuator is hydraulically tested, certified and guaranteed for a minimum of 500,000 cycles.
Pneumatic Actuator - Features 1. Indicator A position indicator with Namur mounting is standard on all HTM pneumatic actuators for mounting accessories.
2. Pinion
1 8 2 5
6 9
4 3
The hardened alloy steel pinion is precision ground and Nickel plated (over 25um) in order to reduce friction, provide maximum wear resistance. Full conformance with the newest standards of ISO5211 & DIN3337. The dimensions can be customized and as options, stainless steel and aluminium are also available.
3. Actuator Body The aluminum extrusion is hard anodized(over 30um) to protect against wear and corrosion while reducing piston friction to the absolute minimum. Other options such as Nickel plating, PTFE and powder polyester painting are available.
4 . End Caps Epoxy coated(over 150um) die cast aluminum end caps provide maximum resistance against potentially corrosive elements. Other treatments such as Nickel plating & PTFE painting are available.
5. Pistons The precisely-balanced and hard anodized treatment (over 30um)die cast aluminum pistons are fitted with high quality rings and guides. The twin rack and piston design creates a constant torque output on all actuators.
6. Travel Adjustment The standard adjustment is Âą 5ă‚œin both the open and closed positions through easily accessible external adjustment bolts.
7. High Performance Springs The high tensile steel springs are coated with zinc phosphate for corrosion resistance and longer service. The pre-loaded springs can be safely & rapidly disassembled.
8. Bearings & Guides The highly durable compound material provides high trust stability with minimum friction and long life.
9. O-Rings NBR O-rings provide trouble-free operation at standard temperature ranges. Viton and Silicone O-rings are available for high or low temperature applications.
Pneumatic Actuator – HTD032 Parts List 11 9 10
12
6 5
10 12 11
15
9
13
14 8
7
7
8
14
13
15
1 4
2
3
Item
Description
Material
Protection
Q’ty
Optional Nickel or PTFE Plated
1
Actuator Body
Extruded Alluminum Alloy
Hard Anodized (over 30um)
1
2
Pinion
Alloy Steel
Nickel Plated (over 25um)
1
3* O-Ring(Lower Pinion)
NBR
1
Viton / Silicone
4* O-Ring(Top Pinion)
NBR
1
Viton / Silicone
5
Thrust Bearing(Pinion)
POM
1
6
Spring Clip
Stainless Steel
1
7
Piston
Die Cast Aluminum Alloy
Hard Anodized (over 30um)
2
8* Piston Seal
NBR
2
9
Stainless Steel
2
10* Stroke Bolt O-Ring
NBR
2
11
Stroke Bolt Washer
Stainless Steel
2
12
Stroke Bolt Retaining Nut
Stainless Steel
2
13
End Cap
Die Cast Aluminum
14*
End Cap Seals
15
End Cap Bolts
Stroke Bolt
Viton / Silicone
2
Nickel or PTFE Plated
NBR
2
Viton / Silicone
Stainless Steel
8
*Note: Recommended spare parts for maintenance.
1-3
Viton / Silicone
Epoxy Coated (over 150um)
Pneumatic Actuator – HTS052~092 Parts List
Item
Description
Material
Protection
Q'ty
1
Screw
ABS+304
1
2
Indicator
Plastic
1
3
Indicator Pin
ABS
4
4
Spring Clip
Stainless Steel
1
5
Thrust Washer (Pinion)
Stainless Steel
1
6*
Thrust Bearing (Pinion)
POM
1
7
Actuator Body Extruded
Extruded Aluminum Alloy
8*
O-Ring (Top Pinion)
NBR
1
9*
Bearing (Top Pinion)
POM
1
10*
Thrust Bearing (Pinion)
POM
1
11
Stroke Cam
Stainless Steel
1
12
Pinion
Alloy Steel
13*
Bearing (Lower Pinion)
POM
14*
O-Ring (Lower Pinion)
NBR
15
Piston
Die Cast Aluminum Alloy
Hard Anodized (over 30μm)
Nickel Plated (over 25μm)
1 Viton/Silicone
1 1 1
Hard Anodized (over 30μm)
16*
Piston Seal
NBR
2
Piston Bearing
POM
2 Zinc Phosphate Coated
18
Spring (Cartridge)
High Performance Spring Steel
19*
End Cap Seals
NBR
2
20
Stroke Bolt
Stainless Steel
1
21
End Cap
Die Cast Aluminum
22
End Cap Bolts
Stainless Steel
8
23
Plug
PE
2
Epoxy Coated (over 150μm)
Viton/Silicone
2
17*
Viton/Silicone
0-12 Viton/Silicone
2
24*
Stroke Bolt O-Ring
NBR
2
25
Stroke Bolt Washer
Stainless Steel
2
26
Stroke Bolt Retaining Nut
Stainless Steel
2
27
Stroke Bolt
Stainless Steel
2
28* Piston Guide POM * Note: Recommended spare parts for maintenance.
Optional
2
Viton/Silicone
Pneumatic Actuator – HTS105~270 Parts List 1 2 3 4 5 6 13 11
12
7 8 10
20
17 16
9
21 18 19
15 14
25 22
23 24
Item
Description
Material
Protection
Q’ty
1
Indicator
ABS
1
2
Spring Clip
Stainless Steel
1
3
Thrust Washer(Pinion)
Stainless Steel
1
4
Thrust Bearing(Pinion)
PTFE+15%Graphite
5
Actuator Body
Extruded Alluminum Alloy
Hard Anodized (over 30um)
Optional
1 1
6
Piston
Die Cast Aluminum Alloy
Hard Anodized (over 30um)
7
Spring(Cartridge)
High Performance Spring Steel
Zinc Phosphate Coated
8*
End Cap Seals
NBR
2
9
End Cap Bolts
Stainless Steel
8
10
End Cap
Die Cast Aluminum
Epoxy Coated(over 150um)
Nickel or PTFE Plated
2 0-12
2
11*
Piston Bearing
POM
12*
Piston Seal
NBR
2
13*
Piston Guide
POM
2
Viton / Silicone
Nickel or PTFE Plated
2 Viton / Silicone
14
Stroke Bolt
Stainless Steel
2
15
Stroke Bolt Retaining Nut
Stainless Steel
2
16
Stroke Bolt Washer
Stainless Steel
2
17*
Stroke Bolt O-Ring
NBR
2
Viton / Silicone
18*
O-Ring(Top Pinion)
NBR
1
Viton / Silicone
19*
Bearing(Top Pinion)
POM
1
20*
Thrust Bearing(Pinion)
POM
1
21
Stroke Cam
Stainless Steel
22
Pinion
Alloy Steel
23*
Bearing(Lower Pinion)
POM
1
24*
O-Ring(Lower Pinion)
NBR
1
Viton / Silicone
25*
Plug
NBR
2
Viton / Silicone
* Note: Recommended spare parts for maintenance.
1-5
1 Nickel Plated (over 25um)
1
Pneumatic Actuator - Double Acting Sizing example of HTM double acting actuator: Valve torque 100Nm plus 30% safety factor= 130N.m. Minimum operating pressure 6bar. By reading down the 6bar column the figure below 130N.m is 136.4N.m, The model number shown in the left hand column is therefore HTD-092.
The operating principle of double acting actuator
CCW-counter-clockwise
CW-clockwise
A
B
A
B
Air to port A forces the pistons outwards, causing the
Air to port B forces the pistons inwards, causing the
piston to turn counter-clockwise while air is being
piston to turn clockwise while air is being exhausted
exhausted from port B.
from port A.
Torque Table of Double Acting Actuator Model
Unit: in.lbs
Air Supply Pressure
Unit: N.m
Model
40 Psi
50 Psi
60 Psi
70 Psi
80 Psi
90 Psi
100 Psi
HTD-032
34
44
55
64
73
81
90
HTD-032
HTD-052
102
127
152
178
203
229
254
HTD-063
179
223
268
313
357
402
HTD-075
289
360
430
502
574
HTD-083
362
453
544
634
HTD-092
555
694
834
HTD-105
829
1040
HTD-125
1423
HTD-140
Air Supply Pressure 3 Bar
4 Bar
5 Bar
6 Bar
7 Bar
8 Bar
4.2
6
7.5
9
10
11.5
HTD-052 12.48
16.64
20.8
24.96
29.12
33.28
447
HTD-063 21.96
29.28
36.6
43.92
51.24
58.56
646
718
HTD-075
35.5
47
58.8
70.5
82.3
94
725
816
906
HTD-083
44.5
59.4
74.2
89.1
103.9
118.8
972
1110
1249
1388
HTD-092
68.2
91.1
113.7
136.4
159.2
181.9
1251
1452
1657
1865
2072
HTD-105 101.82
136.76
169.7
203.64
237.58
271.52
1779
2135
2491
2847
3203
3559
HTD-125 174.9
233.2
291.5
349.8
408.1
466.4
2142
2678
3213
3749
4284
4820
5356
HTD-140 263.22
350.96
438.7
526.44
614.18
701.92
HTD-160
3264
4080
4897
5713
6529
7345
8161
HTD-160 401.1
534.8
668.5
802.2
935.9
1069.6
HTD-190
5261
6576
7891
9207
10522
11838
13153
HTD-190 646.44
861.9
1077.4
1292.9
1508.4
1723.8
HTD-210
7230
9038
10845
12653
14460
16267
18075
HTD-210 888.4
1184.5
1480.6
1776.7
2072.8
2369
HTD-240 11333
14166
16999
19832
22666
25499
28332
HTD-240 1392.5
1856.6
2320.8
2785
3249.1
3713.3
HTD-270 15937
19921
23905
27889
31873
35857
39841
HTD-270 1958.2
2610.9
3263.6
3916.3
4569
5221.8
HTD-300 19557
24450
29344
34234
39123
44012
48901
HTD-300
2403
3205
4006
4807
5608
6409
HTD-350 29283
36606
43931
51255
58575
65896
73221
HTD-350
3598
4798
5998
7197
8397
9596
HTD-400 41816
52216
62599
73030
83462
93893
104325
HTD-400
5138
6837
8546
10255
11964
13673
Pneumatic Actuator - Spring Return (Fail Safe) Sizing example of HTM spring return actuator: Spring to close when air fails(air to open): Valve torque 60N.m plus 30% safety factor = 78N.m. Minimum operating pressure: 6bar. The spring return HTM actuator selected is HTS-125-10. The HTS-125-10 has the following output torques: 1.air torque 0°(valve close) = 173N.m > 78N.m 2.air torque 90°(valve open) = 118N.m > 78N.m 3.spring torque 90゜ (valve open) = 156N.m > 78N.m 4.spring torque 0°(valve close) = 119N.m > 78N.m
The operating principle of single acting spring return actuator CCW-counter-clockwise
A
CW-clockwise
A
B
B
Air to port A forces the pistons outwards, causing the springs
Loss of air pressure through port A allows the stored energy in the
to compress. The pinion turns counter-clockwise while air is
springs to force the pistons inwards. The pinion turns clockwise
being exhausted through port B.
while air is being exhausted through port A.
Mounting Variations
Spring Arrangement
CCW-counter-clockwise
5 Springs
6 Springs
7 Springs
8 Springs
9 Springs
10 Springs
CW-clockwise
12 Springs 11 Springs
Pneumatic Actuator -Torque Table(in.lbs) Unit: in.lbs Model
HTS-052
HTS-063
HTS-075
HTS-083
HTS-092
HTS-105
HTS-125
HTS-140
Spring Set 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12
Spring Torque 0° 35 42 49 56 63 70 77 84 62 75 88 100 112 124 137 150 105 126 147 168 189 210 231 251 128 154 180 205 142 257 282 308 226 271 316 361 406 451 497 542 294 353 412 470 529 588 646 705 526 631 735 841 946 1051 1156 1261 783 940 1097 1253 1410 1567 1723 1880
90° 55 66 77 88 99 110 121 132 96 115 134 153 172 191 210 229 155 186 217 248 279 310 341 363 192 230 269 307 346 384 422 461 336 404 471 538 605 673 740 807 441 529 528 679 705 791 882 970 1059 769 923 1076 1230 1384 1538 1845 1168 1402 1636 1869 2103 2337 2570 2804
40 Psi 0° 90° 47 66 35 59 25 53
117 103 91
184 163 142
234 208 182
329 284 239
535 476 417
898 792 688
1359 1202 1046
83 64 45
134 103 72
170 132 93
219 151 84
388 299 300
365 654 500
974 740 507
50 Psi 0° 90° 72 92 61 84 50 78 39 71
161 148 136 123
255 234 213 192
325 299 273 248
469 424 379 333
746 687 628 570
1254 1148 1044 938
1895 1738 1581 1425
128 109 90 70
205 174 143 112
261 223 184 146
358 291 224 156
599 511 511 361
721 1010 856 703
1510 1276 1042 809
Air Supply Pressure 60 Psi 70 Psi 80 Psi 0° 90° 0° 90° 0° 90° 97 117 86 110 75 104 65 97 90 122 53 90 79 115 43 82 93 133 68 108 82 126 56 101 71 119 46 94 172 206 153 193 134 180 115 168 160 213 96 156 141 200 77 144 166 234 122 189 148 220 103 176 128 208 84 163 276 325 245 305 214 283 183 262 255 334 152 242 224 314 221 293 364 437 293 365 233 343 162 271 211 323 140 251 352 415 314 390 275 364 237 338 327 429 198 401 288 492 315 394 496 575 405 485 303 443 212 352 264 505 173 415 498 608 430 563 363 518 296 473 434 611 428 366 566 229 729 955 1005 817 867 679 370 614 232 475 303 569 165 430 957 810 897 721 839 722 781 773 982 572 721 746 922 545 663 866 1070 660 864 459 776 1011 570 806 687 952 482 746 1609 1077 1504 1366 1400 1212 1294 1059 1650 1415 1189 1545 1261 905 1084 1440 1107 1795 1463 751 1691 1309 953 1335 1586 1002 646 1230 2430 2045 2273 1811 2117 1578 1960 1344 2496 1880 1803 1110 2339 1646 1647 2182 1412 2718 1948 877 2026 1179 2561 1714 2405 1481 945 1869
90 Psi 0° 90°
100 Psi 0° 90°
159 152 144
119 107 97
184 177 170
144 133 122
278 265 253
211 192 173
323 310 297
256 237 218
508 415 394
436 305 283
580 487 466
508 377 355
666 533 596
586 394 355
756 624 687
677 484 445
1144 752 707
1094 509 442
1283 892 846
1233 648 581
1277 1218 1159
1073 983 894
1484 1426 1366
1280 1190 1102
2151 2047 1942
1818 1664 1357
2507 2403 2297
2174 2020 1713
3253 3097 2940
2483 2250 2016
3789 3632 3476
3019 2785 2552
Pneumatic Actuator -Torque Table(in.lbs) Unit: in.lbs Model
HTS-160
HTS-190
HTS-210
HTS-240
HTS-270
HTS-300
HTS-350
HTS-400
Spring Set 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12
Spring Torque 0° 1208 1450 1691 1933 2175 2416 2658 2899 1924 2309 2694 3079 3463 3848 4233 4618 2645 3174 3702 4232 4760 5289 5818 6346 4147 4979 5804 6634 7463 8292 9122 9951 5828 6994 8159 9325 10491 11656 12822 13988 7081 8143 9497 10851 12214 13568 14922 17011 10612 13081 15259 17445 19631 21799 23985 25472 15126 19516 21950 24384 26826 29260 31712 36297
90° 1806 2168 2529 2890 3251 3612 3973 4334 2885 3462 4039 4617 5194 5771 6348 6925 3963 4755 5549 6341 7160 7926 8719 9511 6213 7456 8698 9941 11184 12426 13669 14912 8736 10483 12230 13977 15724 17471 19218 20966 10798 11833 13798 15772 17737 19719 21684 25924 25304 18985 22144 25313 28473 31641 34801 39483 23437 30597 34412 38244 15506 45891 49706 56255
40 Psi 0° 90° 2056 1459 1815 1097 736 1573
3337 2952 2567
4586 4056 3528
7186 6354 5529
10109 8943 7777
12476 11414 10060
2376 1799 1222
3267 2475 1682
5120 3877 2634
7201 5454 3707
8759 7724 5759
50 Psi 0° 90° 2872 2275 2631 1913 2389 1552 2147 1191
4652 4267 3882 3497
6393 5864 5336 4806
10019 9187 8362 7532
3691 3114 2537 1960
5074 4282 3489 2697
7953 6710 5467 4225
14093 11185 12927 9438 11762 7691 10596 5944
17370 13652 16308 12617 14953 10652 13599 8678
18671 3978 25994 16201 10298 23525 14024 7138 21347 19161
11302 17621 14461 11293
26690 18379 37090 28779 26557 19672 36957 30071 19866 7404 30266 17804 27832 13972
Air Supply Pressure 60 Psi 70 Psi 80 Psi 0° 90° 0° 90° 0° 90° 3688 3091 3447 2729 3205 2368 2964 2007 3780 2823 2722 1646 3538 2462 2480 1285 3296 2101 4113 2917 3055 1740 3871 2556 2813 1378 3629 2195 5967 5006 5582 4429 5197 3852 4812 3275 6128 4590 4428 2698 5744 4013 4043 2121 5359 3436 6674 4752 4974 2859 6289 4175 4589 2282 5904 3598 8201 6882 7671 6090 7143 5297 6614 4504 8421 6312 6085 3685 7893 5492 5556 2919 7363 4727 9171 6534 6834 3934 8641 5741 6307 3142 8114 4949 12852 10786 12019 9543 11195 8300 10365 7058 13199 9891 9536 5815 12369 8649 8707 4573 11540 7406 14374 10239 10711 6163 13544 8997 9882 4921 12715 7754 18077 15169 16911 13422 15746 11675 14580 9928 18564 13912 13414 8181 17398 12165 12249 6434 16233 10418 20217 14402 15067 8671 19051 12655 13901 6924 17886 10908 22264 18546 21202 17511 19848 15546 18493 13572 23383 18462 17130 11608 22020 16497 15776 9625 20665 14514 25555 19403 19311 12549 24201 17439 17223 8310 22112 13199 33319 18626 30849 24946 28672 21786 26486 18618 33811 25942 24300 15458 31624 22783 22131 12289 29456 19614 36776 26934 27270 16454 34590 23775 34634 11772 41954 19092 47473 39162 47340 40454 40649 28187 38215 24355 48646 34786 35772 47092 46204 57524 33338 16708 43770 27139 54201 37571 41318 23325 51750 33756 36733 16775 47165 27207
90 Psi 0° 90°
100 Psi 0° 90°
4929 4687 4445
3733 3372 3011
5745 5503 5261
4549 4188 3827
7989 7604 7219
6067 5490 4913
9305 8920 8535
7382 6805 6228
10978 10449 9921
8341 7548 6756
12785 10149 12256 9356 11729 8564
17207 13073 20040 15906 16378 11830 19210 14663 15548 10587 18381 13420
24201 18386 28185 22370 23035 16639 27019 20623 21870 14892 25854 18876
30444 24293 35333 29182 29090 22328 33979 27217 27001 18088 31890 22978
44097 34255 51421 41579 41911 31095 49235 38420 49274 26413 56599 33738
64633 48003 75065 58434 62181 44188 72613 54620 57597 37638 68028 48070
Pneumatic Actuator -Torque Table(Nm) Unit: N.m Model
HTS-052
HTS-063
HTS-075
HTS-083
HTS-092
HTS-105
HTS-125
HTS-140
Spring Set 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12
Spring Torque 0° 4.0 4.8 5.5 6.3 7.1 7.9 8.7 9.5 7.0 8.5 9.9 11.3 12.7 14.0 15.5 16.9 11.9 14.2 16.6 19.0 21.3 23.7 26.1 28.4 14.5 17.4 20.3 23.2 16.1 29.0 31.9 34.8 25.5 30.6 35.7 40.8 45.9 51.0 56.1 61.2 33.2 39.9 46.5 53.1 59.8 66.4 73.0 79.7 59.4 71.3 83.1 95.0 106.9 118.8 130.6 142.5 88.5 106.2 123.9 141.6 159.3 177.0 194.7 212.4
90° 6.2 7.5 8.7 9.9 11.2 12.4 13.7 14.9 10.8 13.0 15.1 17.3 19.4 21.6 23.7 25.9 17.5 21.0 24.5 28.0 31.5 35.0 38.5 41.0 21.7 26.0 30.4 34.7 39.1 43.4 47.7 52.1 38.0 45.6 53.2 60.8 68.4 76.0 83.6 91.2 49.8 59.8 59.7 76.7 79.7 89.4 99.6 109.6 119.6 86.9 104.3 121.6 139.0 156.4 173.8 208.5 132.0 158.4 184.8 211.2 237.6 264.0 290.4 316.8
3 Bar 0° 8.5 7.7 7.0
15.0 13.5 12.0
23.4 21.1 18.7
30.9 28.1 25.2
50.3 45.2 40.1
68.6 61.9 55.3
115.5 103.6 91.8
174.7 157.0 133.9
4 Bar 90° 5.3 5.0 3.8
11.2 9.0 6.9
17.8 14.3 10.8
23.8 19.5 15.1
37.8 30.2 22.6
52.0 42.0 32.1
88.0 70.6 53.5
131.2 104.8 78.4
0° 12.6 11.8 11.1 10.3 9.5 8.7
90° 10.4 9.1 7.9 6.7 5.4 4.1
22.3 20.8 19.4 18.0 16.5 15.3 13.8
18.5 16.3 14.2 12.0 9.9 7.7 5.6
35.1 32.8 30.4 28.0 25.7 23.3
29.5 26.0 22.5 19.0 15.5 12.0
46.1 43.3 40.3 37.4 34.5 31.6
38.9 34.6 30.2 25.9 21.5 17.2
75.5 70.4 65.3 60.2 55.1 50.0
63.0 55.4 47.8 40.2 32.7 25.0
103.6 96.9 90.3 83.7 77.0 70.4
87.0 77.0 67.1 57.1 47.4 37.2
173.8 161.9 105.1 138.2 126.3 114.4
146.3 128.9 111.6 94.2 76.8 59.4
262.5 244.8 227.1 209.4 191.7 174.0
219.0 192.6 166.2 139.8 113.4 87.0
Air Supply Pressure 5 Bar 0° 90°
6 Bar
7 Bar
0°
90°
0°
90°
17.1 16.3 15.5
12.6 11.3 10.1
20.4 19.6
15.4 14.2
32.6 31.2 29.9 28.4 27.0
26.6 24.5 22.3 20.2 18.0
37.2 35.7 34.3
29.6 27.5 25.3
14.5 13.7 12.9 12.1 11.3 29.6 28.1 26.7 25.3 23.9 22.6 21.1 19.7
10.9 9.6 8.4 7.1 5.9 25.8 23.7 21.5 19.3 17.2 15.0 12.9 10.7
39.8 37.5 35.1 32.7 30.4
30.8 27.3 23.8 20.3 16.8
46.8 44.4 42.1
35.5 32.0 28.5
58.6 56.2 53.9
47.3 43.8 40.3
52.6 49.7 46.8 43.9 41.0
41.1 36.7 32.4 28.1 23.7
62.0 59.1 56.2
47.6 43.3 38.8
77.1 74.2 71.3
62.7 58.4 54.0
85.5 80.4 75.3 70.2 65.1
65.5 57.9 50.3 42.7 35.1
100.6 95.5 90.4
75.6 68.0 60.4
125.8 120.7 115.6
100.8 93.2 85.6
116.6 109.9 103.3 96.7 90.0
90.0 80.3 70.1 60.1 50.2
137.3 130.6 123.9
104.0 94.0 84.1
171.2 164.4 157.9
138.0 128.0 118.1
196.5 184.6 172.7 160.9 149.0
152.5 135.1 117.7 100.4 83.0
231.0 219.2 207.3
176.0 158.7 141.3
277.5 265.6
217.0 199.6
297.1 279.4 261.7 244.0 226.3
227.5 201.1 174.7 148.3 121.9
349.4 331.7 314.0
262.4 236.0 209.6
437.8 419.5 401.8
350.1 323.8 297.4
Pneumatic Actuator -Torque Table(Nm) Unit: N.m Model
HTS-160
HTS-190
HTS-210
HTS-240
HTS-270
HTS-300
HTS-350
HTS-400
1-11
Spring Set 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12 5 6 7 8 9 10 11 12
Spring Torque 0° 136.5 163.8 191.1 218.4 245.7 273.0 300.3 327.6 217.4 260.9 304.4 347.9 391.3 434.8 478.3 521.8 298.8 358.6 418.3 478.1 537.8 597.6 657.4 717.0 468.5 562.6 655.8 749.5 843.2 936.9 1030.6 1124.3 658.5 790.2 921.9 1053.6 1185.3 1317.0 1448.7 1580.4 800 920 1073 1226 1380 1533 1686 1922 1199 1478 1724 1971 2218 2463 2710 1878 1709 2205 2480 2755 3031 3306 3583 4101
90° 204.0 244.9 285.7 326.5 367.3 408.1 448.9 489.7 326.0 391.2 456.4 521.6 586.8 652.0 717.2 782.4 447.8 537.3 626.9 716.4 809.0 895.5 985.1 1074.6 702.0 842.4 982.8 1123.2 1263.6 1404.0 1544.4 1684.8 987.0 1184.4 1381.8 1579.2 1776.6 1974.0 2171.4 2368.8 1220 1337 1559 1782 2004 2228 2450 2929 2859 2145 2502 2860 3217 3575 3932 4461 2648 3457 3888 4321 1752 5185 5616 6356
3 Bar 0° 264.6 237.3 210.0 182.7
429.0 385.5 342.0
589.6 529.8 470.1
924.0 829.9 736.7
1299.7 1168.0 1036.3
1603 1483 1330 1177
2399 2120 1874 1627
3418 2922 2647 2372
90° 197.1 156.2 115.4 74.6
320.4 255.2 190.0
440.6 351.1 261.5
690.5 550.1 409.7
971.2 773.8 576.4
1183 1066 844 621
1739 1453 1096 738
2479 1670 1239 806
4 Bar 0° 398.3 371.0 343.7 316.4 289.1 261.8
90° 330.8 289.9 249.1 208.3 167.5 126.7
644.5 601.0 557.5 514.0 470.6 427.1
535.9 470.7 405.5 340.3 275.1 209.9
885.7 825.9 766.2 706.4 646.7 586.9
736.7 647.7 557.6 468.1 375.5 289.0
1488.1 1294.0 1200.8 1107.1 1013.4 919.7
1154.6 1014.2 873.8 733.4 593.0 452.6
1952.4 1820.7 1689.0 1557.3 1425.6 1293.9
1623.9 1426.5 1229.1 1031.7 834.3 636.9
2132 1978 1825 1652
1646 1423 1201 977
3074 2827 2580 2335
2296 1938 1581 1223
4357 4082 3806 3531
2949 2516 2085 1652
Air Supply Pressure 5 Bar 0° 90°
6 Bar
7 Bar
0°
90°
0°
90°
450.1 422.8 395.5 368.2 340.9
341.9 301.2 260.4 219.6 178.8
529.2 501.9 474.6
394.1 353.3 312.5
706.9 635.6 608.3
549.1 487.0 446.2
729.5 686.1 642.6 599.1 555.6
555.8 490.6 425.4 360.2 295.0
858.1 814.6 771.1
640.9 575.7 510.5
1073.6 1030.1 986.6
856.4 791.2 726.0
1002.5 942.8 883.0 823.2 763.5
764.2 671.6 585.1 495.5 406.0
1179.1 1119.3 1059.6
881.2 791.6 702.1
1475.2 1415.4 1355.7
1177.3 1087.7 998.2
1571.3 1477.6 1383.9 1290.2 1196.5
1197.6 1057.2 916.8 776.4 636.0
1848.1 1754.4 1660.7
1381.0 1240.6 1100.2
2312.2 2218.5 2124.8
1846.1 1704.7 1564.3
2210.0 2078.3 1946.6 1814.9 1683.2
1684.4 1487.0 1289.6 1092.2 894.8
2599.3 2467.7 2335.9
1942.3 1744.9 1547.5
3252.0 3120.3 2988.6
2595.0 2397.6 2200.2
2780 2626 2473 2320 2014
2224 2002 1778 1556 1077
3427 3274 3121 2815
2803 2579 2357 1878
4075 3922 3686
3380 3158 2679
4027 3780 3535 3288 3120
3138 2781 2423 2066 1537
4979 4734 4487 4319
3980 3622 3265 2736
5934 5687 5519
4822 4465 3936
5791 5515 5240 4963 4445
4225 3794 3361 2930 2190
7224 6949 4472 6154
5503 5070 4639 3899
8658 8381 8106
6779 6348 5608
Pneumatic Actuator - Dimension Table C
24
G
32
B
D
M5-8 4- #10-32UNF
E
1/4" NAMUR
F
A
M6
40
12
4
5.3
M6-10 4- 1/4"-20UNC
4-M5x0.8
H
o
45
45
PCD ФJ
I
N
PCD ФK
4-M2 4-M1
1/2" NAMUR
Dimension Table Model HT-032 HT-052 HT-063 HT-075 HT-083 HT-092 HT-105 HT-125 HT-140 HT-160 HT-190 HT-210 HT-240 HT-270 HT-300 HT-350 HT-400
A
B
C
D
E
F
G
H
I
N
114 4.49 158.4 6.24 190 7.48 207 8.15 213 8.39 259 10.2 287 11.3 340 13.39 414 16.3 476 18.74 535 21.06 567.5 22.34 668 26.3 744 29.29 830 32.68 920 36.22 1012 39.84
45 1.77 74 2.91 88 3.46 100 3.94 109 4.29 120 4.72 133 5.24 155 6.1 171.5 6.75 197 7.76 230 9.06 255 10.04 291.4 11.47 320 12.6 362 14.25 413 16.26 465 18.31
47 1.85 60 2.36 69 2.72 79 3.11 88 3.46 97.5 3.84 105.5 4.15 120.5 4.74 137 5.39 159.5 6.28 186 7.32 202 7.95 233 9.17 264 10.39 389 15.31 443 17.44 496 19.53
65 2.56 94 3.7 108 4.25 120 4.72 129 5.08 140 5.51 153 6.02 175 6.89 191.5 7.54 217 8.54 260 10.24 285 11.22 321.4 12.65 350 13.78 392 15.43 443 17.44 495 19.49
23.5 0.93 30 1.18 36 1.42 42 1.65 46 1.81 51 2.01 57.5 2.26 67.5 2.66 76 2.99 86.5 3.41 103 4.06 113 4.45 129 5.08 146 5.75 194.5 7.66 221.5 8.72 248 9.76
23.5 0.93 41 1.61 45 1.77 52 2.05 52.5 2.07 57.5 2.26 64 2.52 70 2.76 77 3.03 87.5 3.44 103 4.06 113 4.45 129 5.08 146 5.75 194.5 7.66 221.5 8.72 248 9.76
14 0.55 14 0.55 18 0.71 20 0.79 21 0.83 22 0.87 24 0.94 27.5 1.08 32 1.26 34 1.34 40 1.57 40 1.57 50 1.97 57 2.24 57 2.24 60 2.36 60 2.36
50 1.97 80 3.15 80 3.15 80 3.15 80 3.15 80 3.15 80 3.15 80 3.15 80 3.15 80 3.15 130 5.12 130 5.12 130 5.12 130 5.12 130 5.12 130 5.12 130 5.12
25 0.98 30 1.18 30 1.18 30 1.18 30 1.18 30 1.18 30 1.18 30 1.18 30 1.18 30 1.18 30 1.18 30 1.18 30 1.18 30 1.18 30 1.18 30 1.18 30 1.18
9 0.35 11 0.43 14 0.55 14 0.55 17 0.67 17 0.67 22 0.87 22 0.87 27 1.06 27 1.06 36 1.42 36 1.42 46 1.81 46 1.81 46 1.81 55 2.17 55 2.17
J F03
K --
F05
F03
F07
F05
F07
F05
F07
F05
F07
F05
F10
F07
F10
F07
F12
F10
F12
F10
F14
--
F14
--
F16
--
F16
--
F16
F25
F16
F25
F16
F25
M1 M5x8 #10-24UNC M6×11 1/4"-20UNC M8×15 5/16"-18UNC M8×13 5/16"-18UNC M8×15 5/16"-18UNC M8×13 5/16"-18UNC M10×18 3/8"-16UNC M10×18 3/8"-16UNC M12×22 1/2"-13UNC M12×22 1/2"-13UNC M16×23 5/8"-11UNC M16×25 5/8"-11UNC M20×28 3/4"-10UNC M20×28 3/4"-10UNC M20×28 3/4"-10UNC M20×28 3/4"-10UNC M20×28 3/4"-10UNC
M2
Air Inlet
--
1/8"
M5×10 #10-24UNC M6×12 1/4"-20UNC M6×11 1/4"-20UNC M6×12 1/4"-20UNC M6×12 1/4"-20UNC M8×14 5/16"-18UNC M8×14 5/16"-18UNC M10×18 3/8"-16UNC M10×18 3/8"-16UNC
1/8"or1/4" 1/8"or1/4" 1/8"or1/4" 1/8"or1/4" 1/8"or1/4" 1/4" 1/4" 1/4" 1/4"
--
1/4"
--
1/4"
--
1/4"or3/8"
--
1/4"or1/2"
M16×23 5/8"-11UNC M16×23 5/8"-11UNC M16×23 5/8"-11UNC
1/2" 1/2" 1/2"
Pneumatic Actuator - Technical Data Air Consumption - Air Volume Opening & Closing Model
Air Volume@opening (liter/cu.in)
Air Volume@closinging (liter/cu.in)
0.03 1.71 0.09 5.49 0.14 8.54 0.21 12.81 0.29 17.69 0.49 29.90 0.70 42.71
0.04 2.32 0.12 7.32 0.20 12.20 0.30 18.30 0.41 25.02 0.71 43.32 0.99 60.40
HT-32 HT-52 HT-63 HT-75 HT-83 HT-92 HT-105
Model
Air Volume@opening (liter/cu.in)
Air Volume@closinging (liter/cu.in)
1.20 73.22 1.70 103.72 2.60 158.63 4.20 256.25 5.70 347.77 9.00 549.12 12.60 768.76
1.60 97.62 2.40 146.43 3.70 225.75 5.90 359.98 8.20 500.31 12.80 780.97 17.90 1092.13
HT-125 HT-140 HT-160 HT-190 HT-210 HT-240 HT-270
The Table of Actuators Weight & Opening Closing Time Model
HT-032 D S
Screw stroke adj. for 1째 adj. need
-----
HT-052 D S
HT-063 D S
HT-075 D S
1/5 turn
1/5 turn
1/5 turn
HT-083 D S 1/5 turn
HT-092 D S
HT-105 D S
1/4 turn
1/4 turn
Opening time (Sec.)
0.03
---
0.2
0.25
0.25
0.3
0.3
0.35
0.4
0.5
0.5
0.6
0.7
0.8
Closing time (Sec.)
0.03
---
0.25
0.3
0.3
0.35
0.4
0.5
0.5
0.6
0.7
0.9
0.9
1.1
0.5/1.1
---
1.0/2.2 1.0/2.2 1.6/3.5 1.8/4.0 2.6/5.7 3.1/6.8 3.1/6.8 3.6/7.9 4.9/10.8 5.7/12.5 6.5/14.3 7.7/16.9
Approximate weight (Kg/Lbs)
Model
HT-125
HT-140
HT-160
HT-190
HT-210
HT-240
HT-270
D
D
D
D
D
D
D
Screw stroke adj. for 1째 adj. need
S
1/4 turn
S
1/4 turn
S
1/4 turn
S
1/3 turn
S
1/3 turn
S
1/3 turn
S
1/3 turn
Opening time (Sec.)
0.9
1.1
1.3
1.5
1.6
1.8
2.2
2.4
2.9
3.4
3.8
4.3
4.5
5.0
Closing time (Sec.)
1.2
1.4
1.6
1.9
1.9
2.2
2.6
3.0
3.8
4.1
4.4
5.0
5.0
5.5
Approximate weight (Kg/Lbs)
9.9/21.8 11/24.2 13.8/30.4 16.3/35.9 19/41.8 24/52.8 28/61.6 34/74.8 37/81.4
45/99
52/114.4 64/140.8 85/187 104/228.8
Order Information Type HTD Double Acting Actuator
Model 032
Spring Set Blank
Seals Blank
052 (Double Acting Actuator) (standard NBR seals) 063 05 HTS 075 06 HT= Viton seals Spring Return Actuator 083 07 (for high temperature) 092 08 HTDN 105 09 LT= Silicone seals Double Acting Actuator 125 10 (for low temperature) (Nickel Plated Housing) 140 11 160 12 HTSN 190 Spring Return Actuator 210 (Nickel Plated Housing) 240 270 Note: The part numbers are represented as the following: Type-Model-Spring Set-Seals-Options
Options 120 120째operation 180 180째operation SS Stainless Steel Housing
HTM VALVES
ELECTRIC ACTUATOR HTE Series
HTE Electric Actuator – Features 1
2
3
4
5
6
7
8
1. Due to characteristics of valve, the electric actutor must be able to provide high start up torque with full load whenever the valve is at open, closed or any other position. HTM HTE series electric actuators are designed for such working requirement. 2. Gear driving unit is made of alloy steel with heat treatment featuring high strength, excellent wear resistance and long term fatigue load impact. 3. The crank handle is designed as detachable to minimise the dimension of the actuator. 4. The integral construction of the wormgear and drive shaft provides long term dependable operation with high output torque. 5. The captive cover bolt prevents bolt from dropping when cover is opened. 6. The stainless steel stroke bolt and cam provide 0 - 90° adjustability. 7. The tempered glass visual position indicator provides anti-aging, temperature resistance and anti-deformation. 8. The epoxy encapsulated control servo unit provides heat insulation, moisture and dust proofing, thus suitable for various industrial process requirements.
2-1
HTE Electric Actuator - HTE - 02S Technical Data
102
8-M
42
50
36
Amb Temp : 30℃ ℃ Output Torque 18NM Operation Time : 12S Enclosure : IP168
5
35.5
Model : HTE-02S Power Supply 200VAC Rated Current : 0.15A Frequency 50/60Hz
6
36
50
4-M
38.5
16.5
72
Crank Handle
G1/4" with cable gland & 30cm lead wire
MANUAL OPERATION IS FORBIDDEN WHEN ENERGIZING
Bottom View
9x9 11x11 Depth:17mm
Bottom View
Model
HTE-02S
Power
110/220VAC
Output Torque(N.m/in.lbs)
18/160
Operation Speed(sec.)
Model : HTE-02S Power Supply 200VAC Rated Current : 0.15A Frequency 50/60Hz
Amb Temp : 30℃ ℃ Output Torque 18NM Operation Time : 12S Enclosure : IP168
9/80
18/160
6
12
12
Power Consumption(W)
6 8
Rated Current(A)
0.15
Insulation Resistance
100MΩ@500VDC
100MΩ@250VDC Ω 550VAC@1 Min.
1.10
0.28
Withstand Voltage
1500VAC@1 Min.
Thermal Protection
standard accessory, built-in,auto-reset type
Mounting Direction
All directions -30 ~ +60
Valve Connection
ISO5211,
Dimension(mm)
Manual Operation
9/80
6
Ambient Temp.
MANUAL OPERATION IS FORBIDDEN WHEN ENERGIZING
24VDC
9/11mm x F03/F04/F05
72(W) x 75(L) x 120(H)
Enclosure
IP68
Housing Material
Die-casting aluminum alloy
Weight(Kg/Lbs)
1.2/2.65
Wiring Diagram Y&G
PE
Brown
Full-open signal
Grey
M
C
OLS
Black
CLS
Red
Full-close signal
Opnen
K Blue
Type:A
Y&G
PE
Full-close signal
Grey
Full-open signal
Brown
Full-open signal
Brown
Full-close signal
White
COM
COM Open
White
L M
Close N
C
Y&G
PE
Grey
OLS
Black
CLS
Red Blue
Type:B
K
OLS L
Close N
M
D1 Black
CLS
Red Close Open D2
Type G(24VDC)
2-2
HTE Electrical Actuator - Technical Data Technical Data Model
HTE-02
HTE-03
HTE-05
HTE-10
HTE-20
HTE-40
Output Torque -(N.m)
20
30
50
100
200
400
600
1000
1600
2000
Operational Speed (Sec.) @ 0-90°/50Hz
4
10
20 / 60
30 / 60
30 / 60
30 / 60
45
30
48
60
0-360゜
0-360゜
0-90゜
0-90゜
0-90゜
0-90゜
0-90゜
0-90゜
Operational Angle(Max.)
0-360゜ 0-360゜
HTE-60 HTE-100 HTE-160 HTE-200
DC motor AC motor 24VDC 110VAC Rated Current - (A) 220VAC 380VAC
13 10 1.28 0.24 0.16 -----
13 10 1.28 0.24 0.16 -----
13 10 1.28 0.24 0.16 -----
25 25 2.03 0.57 0.35 0.10
35 40 3.57 0.65 0.37 0.15
70 90 5.13 1.12 0.57 0.29
70 90 6.04 1.18 0.60 0.29
----120 -----
----140 -----
----140 -----
1.93 0.94 0.44
1.75 0.96 0.46
1.75 0.98 0.48
Duty Rating
30
30
30
30
30
30
30
30
30
30
Weight - (Kg)
2.0
2.0
2.0
3.0
8.0
8.5
9.0
17.0
17.5
18.0
Power - (Watts)
Power Supply
1 Phase: 110/220VAC±10% @ 50/60Hz, 3 Phase/ 380VAC±10% @ 50/60Hz, 12VDC, 24 VDC
Thermal Protector
Standard accessory; built-in, auto-reset type
Insulation Resistance
24VDC:100MΩ @ 250VDC,110/220/380VAC:100MΩ @ 500VDC,
Withstand Voltage
24VDC: 550VAC @ 1Min. , 110/220VAC: 1500VAC @ 1Min. , 380VAC:1800VAC @ 1Min.
Enclosure Rating
IP68
Ambient Temperature
- 30 ~ +60℃
Mounting Direction
All directions
Electrical Conduit
G1/2" with cable gland for standard type(2xG1/2" with cable gland for modulating type)
Manual Operation
Detachable crank handle(standard accessory)
Stopper
In operation: limit switches at full & closed position.Manual operation: mechanical stopper
Housing Material
Die-casting aluminum alloy 1.Type A: standard type 2.Type B: additional limit switches(2units) 3.Type C: potentiometer unit(1KΩ or 500Ω) 4.Type D: potentiometer unit(1KΩ or 500Ω) with additional limit switches(2units)
Various Options
5.Type E: modulating controller(input signal : 4-20mA or 1-5VDC, output signal: 4-20mA) 6.Type F: current position transmitter(output signal : 4-20mA) 7.Space heater 8.Torque switches(2units) 9.Various voltages(110/220/380VAC & 24VDC, the other voltage is available upon request) 10.Various mounting brackets
HTE Electrical Actuator - Technical Data(Quick Open Type) Output Torque -(N.m)
HTE Electric Actuator – Control Function Type A: With Limit Switch (Standard Type) Function: The opening & closing opeation is controlled by the external control circuit. Output signal comes from the power line at open and closed positions of valve.
Multi-Color Full-Open Indication
Full-Closed Indication Valve Open
Valve Closed
Type B: With Additional Switches
Full-Open Indication
Function: The opening and closing operation is controlled by the external control circuit having 1 NO (normally open) & 1 NC (normally closed) output switches. Construction: With two intermediate position switches
Full-Closed Indication
Valve Open
Valve Closed
Type C: With Potentiometer Function: The valve opening position is controlled by the external control circuit. The output: 500Ω or 1000Ω potentiometer is relative to the valve position. Valve Open
Construction: With 500Ω, or 1000 Ω .
Valve Closed
Type D: With Potentiometer and Additional Switches Function: The valve opening position is controlled by the external control circuit. The output: 1 NO( normally open) & 1NC(normally closed) output switch with 500Ω
Full-Open Indication
Full-Closed Indication
or 1000Ω potentiometer. Construction: With potentiometer and intermediate position switches.
Valve Open BLUE
C CLS
Valve Closed
HTE Electric Actuator – Control Function Type E: With Modulating Servo Module (Modulating Type)
Output Signal
Function: Modulating Type, input signal: 4~20mADC or 1~5VDC; output signal: 4~20mADC.
Input Signal
Construction: With servo control module and 1KΩ potentiometer
Type F: With R/I Converter
Output Signal
Function: The output signal 4-20mADC is relative to the valve position.
Valve Open Valve Closed
Construction: With R/I converter and 1KΩ potentiometer
Multi-Color
DC Motor With Intermediate Position Switch
Full-Open Signal Full-Closed Signal
Function: By means of polarity exchange from the external control circuit to change the rotation.The output signal:1 NO Valve Open
(normally open) & 1NC(normally closed) output switch.
Valve Closed
Construction: With intermediate-position switches.
Multi-Color
3-Phase, 380 VAC Control Circuit for AC Motor Function: By means of the external phase-reversing circuit to change the rotation. The output signal: 1 NO (normally open) & 1NC(normally closed) output switch. Construction: With intermediate position switches.
Full-Open Signal Full-Closed Signal
HTE Electric Actuator - Dimension Table
Actuator+Mounting Bracket+Coupling Model HTE-03/05 & K1 HTE-10 & K2 HTE-20 & K3 HTE-40/60 & K4 HTE-100/160 HTE-200
A 60 80 80 100 80 100
B 28 35 48 48 65 65
C
follow valve's dimension
Actuator + ISO-5211 Mounting Bracket Model HTE-03/05 & K1 HTE-10 & K2 HTE-20 & K3 HTE-40/60 & K4 HTE-100/160 HTE-200
A 19 33 45 45 47 67
B 22 36 48 48 50 70
C 70 90 125 125 135 175
D E 50 36 70 50 102 70 102 70 125 102 165 140
F 4-M6 4-M8 4-M10 4-M10 4-M10 4-M16
G 4-M5 4-M6 4-M8 4-M8 ---------
◇H 9 /11/14 9 /11/14 14/17 17/22 22/27 36
□
Bare Shaft Actuator Model
HTE-02/03/05 & K1 HTE-10 & K2 HTE-20/40 &K3 HTE-60 & K4 HTE-100/160/200
2-7
A 113 121 158 158 207
B 160 196 255 255 310
C 102.5 126 148 148 162
D 63 71 95 95 120
E F G H 49 83 77 72 50 98 98 86 63 121 134 106 63 121 134 106 87 148 162 140
I J K □L 60 80 68 12 70 98 82 15 84 135 118 23 84 135 118 25 116 160 136 30
M 12 12 23 23 26
N O P Q 63 70 8-M6 4-M8 ----- 70 ----8-M8 ----- ----- 4-M8 4-M10 ----- ----- 4-M8 4-M10 ----- ----- 4-M10 4-M12
HTM VALVES
ELECTRIC ACTUATOR HTQ Series
HTQ Electric Actuator – Features 1. Housing:hard-anodized AL alloy and external coating of epoxy powder is suitable for the severe
condition
especially
against
the
corrosion.Housing is designed in accordance with standard of Explosion-proof and IP67. and also we can offer HTMTM HTQ with IP68 for option. 2. Motor: specially designed with squirrel caged induction motor to generate high starting torque and high efficiency equipped with thermal protector to prevent damage from over heating.it has several features such as high output power,high efficiency and lower noise. 3. PCU:
high
performance
microprocessor,
auto-calibration
provides the most convenient to user without complicated set in field. 4. Sealing: sealing provided by double O-ring system. 5. Handwheel: Just by pulling over the lever, operating mode is switched to manual. then just supplying electrical power to actuator, clutch is automatically disengaged from manual and operating mode is switched to electric operation. The size of hand wheel is designed according to required torque to move the actuator, so that operator can easily move the actuator by hand. 6. Gear & self locking: 2nd staged double worm gearing prevents movment caused by backward force transferred from valve and it provides the exact and stable position of actuator and valve when the power is off. High efficiency, high output torque, low noise level are another advantages.
3-1
HTQ Electric Actuator – Features 7. Limit switches: directly engaged with driving shaft to set accurate position of valve. Torque swithces: to protect actuator from dama ge caused by over torque from the driven valve over the whole travel. 8. Anti-condensation space heater: the switch is open when the temperature is around 20±3 to protedct actuator condensation; The switch is close when the temperature is over 30±3
to prevent over heating.
9. Stopper bolt: stopper bolt installed both close and open direction prevents actuator’s travel the limit during manual operation and also protects internal gearing from its breakaway. 10. Indicator: through the large size indicator window provides bettr position indication form a distance. 11. Terminal block: it is easy to add the number of strip for additional connection, spring loaded terminal strip is very strong against vibration. 12. Wiring: the inside wiring is so simple and easy to connect. 13. Driving bushing: the driving bushing is removable to process, mounting base is designed according to ISO5211, it is convenient to adapt with valve. 14. Lubrication:
all
the
gears
and
shafts
use
CIATM221 type Grease Moly, it is not necessary to refill lubricant for 5 years. 15. Anti-interference magnetic loop: it effectively prevents the actuator from outside magnetic field, and keeps the actuator operating stable.
HTQ Electric Actuator – Features HTMTM HTQ electric actuator guaranty high performance and stable quality product throughout severe test and inspection. We can provide advanced intelligent model with different models for option. 1. Using very large scale digital integrated chip, so it has very powerful function and high accuracy. Once the actuator is supplied power, it will auto-check the control circuit to insure the correct operation. 2. Displacement transducer of actuator is n. hall sensor with digital quantization impulse signal, Hall magnetically pulse effects system can measure and control the travel of actuator exactly. 3. Using IA infrared ray system, communication compatible with
IA
always
IrDA.
The
supports function
specification of actuator can be set, adjusted and operated by handheld infrared remote controller, it is not necessary to open the top cover to reveal the inner control circuit. 4. Using liquid crystal display with high-resolution, English mark to indicate the travel percent of valve, It is very convenient to use in the night. LED signal with high lightness to indicate the position of actuator: full open-Red, full close-Green. The backup batteries will support the LED display when the main power is off. 5. The remote and local control (open/close/stop) function, with local lamp indication: full colse-Green (on). Closing-Green (flickering). Torque switch trip-Yellow (on), Fault-Yellow (Flickering). Full open-Red(on), Opening-Red(Flickering). Reversing,
electronic
contactors,
Transformer,
Phase
discriminator has detection and auto-correction. 24 to 48 points terminal strips on terminal block for option. Position monitoring relays with remote position indication, local digital position indication.
HTQ Electric Actuator – Standard Specification NEMA
(SPDT 250VAC/10A rating except for HTQ100)
Set
Yes
Space heater
powder
HTQ Electric Actuator – Option Availability
Exd II BT4, BT6, CT4, CT6
central
HTQ Electric Actuator – Technical Information
HTQ100 HTQ160
Type
HTQ240 HTQ350
HTQ500 HTQ800 HTQ1100 HTQ1500 HTQ2000 HTQ3000
Torque(N.m)
100
160
240
350
500
800
1100
1500
2000
3000
Duty cycle(%)
40
30
30
30
30
30
30
30
30
30
Operating
50Hz
21
26
26
31
31
39
39
93
117
117
time(sec)
60Hz
18
22
22
26
26
32
32
78
97
97
Max bore
Key type
22
25
25
40
40
48
48
75
75
75
size(mm)
Squaretype
20
23
23
34
34
40
40
64
64
64
50Hz
0.98
1.60
1.62
1.72
3.60
3.90
3.90
3.60
3.80
3.80
60Hz
1.10
1.70
1.72
1.80
3.90
4.20
4.30
3.90
4.20
4.20
1Phase/220V
50Hz
0.52
0.85
0.87
0.92
1.50
2.05
2.15
1.50
2.05
2.15
~230V
60Hz
0.58
0.90
0.90
0.95
1.60
2.20
2.30
1.60
2.20
2.30
3Phase/380V
50Hz
0.43
0.30
0.32
0.32
0.52
0.82
0.84
0.52
0.82
0.84
~400V
60Hz
0.33
0.30
0.32
0.32
0.56
0.88
0.90
0.56
0.88
0.90
3Phase/440V
50Hz
0.59
0.30
0.32
0.32
0.55
0.82
0.84
0.55
0.82
0.84
60Hz
0.42
0.32
0.35
0.35
0.58
0.88
0.88
0.58
0.88
0.88
F
F
F
F
F
F
F
F
F
F
Motor power
15W
40W
40W
40W
90W
180W
180W
90W
180W
180W
ISO 5211 mounting flange
F07
F07/F10
F16
F16
F16
Weight(kgs)
7
15
15
15
20
25
25
65
75
75
No. of handwheelturns
10
12
12
14
14
17
17
65
70
70
Rated current(A) 1Phase/110V
Motor insulation class
F10/F12 F10/F12
F12/F14
F12/F14 F12/F14
HTQ Electric Actuator – Construction
HTQ Electric Actuator – Construction
HTQ Electric Actuator – Dimension
HTQ Electric Actuator – Dimension
HTQ Electric Actuator – Dimension Mounting Dimension
HTQ-100
HTQ-160,240
HTQ-1500,2000,3000
HTQ-350,500
HTQ-100
HTQ-160,240
HTQ-800,1100
HTQ-350,500
HTQ-800,1100
HTQ-1500,2000,3000
HTQ Electric Actuator – Wiring Diagram Wiring Diagram(HTQ100)
Wiring Diagram(HTQ160——HTQ3000)
HTQ Electric Actuator – Wiring Diagram Wiring Diagram(HTQ160——HTQ3000)
Wiring Diagram(HTQ160——HTQ3000)
HTQ Electric Actuator – Wiring Diagram Wiring Diagram(HTQ100——HTQ300)
HTQ Electric Actuator – Wiring Diagram
HTQ Electric Actuator – Wiring Diagram (LD2 for 3phase) Wiring Diagram
HTQ Electric Actuator – Wiring Diagram PCU Wiring Diagram
HTQ Electric Actuator – Order Information
HTQ - □□□□□□□ Mode
Torque
HTQ 100 N.m
Power
Control Type
Protection
Exposion-proof Operating Time
Others
1) 24V DC
1) ON/OFF
1) IP67
0) non
0) common
0) none
160 N.m
2) 230V AC
2) Modulating 2) IP68
1) ExB
1) special
1) yokes and etc.
240 N.m
3) 400V AC
3) Others
2) EE C
350 N.m
4) Other
2) local control unit 3) FS
500 N.m
4) LCD
800 N.m
5) ray
1100 N.m
6) foundation fieldbus
1500 N.m 2000 N.m 3000 N.m
HTM VALVES
The Accessoris for Pneumatic Actuator
Namur Solenoid Valve - HSV300 series NAMUR SOLENOID VALVE
HSV310-08
HSV320-08 Air Internal Piloted 5 Port 2 Position 35mm2 Inlet & Exhaust Port:PF1/4" Not Required 0.15 ~ 0.8 Mpa 12bar -5 ~ 60 (23 ~ 140°F) -15% ~ 10% AC=2.0~3.5VA, DC=2.5W Class F IP65(DIN40050) Socket with Plug 5 cycle/second
Medium Operating Valve Type Orifice Size Port Size Lubrication Pressure Range Proof Pressure Temp. Range Voltage Range Power Consumption Insulation Class Protecion Connector Max Frequency
Note: Port thread PT and NPT are also available.
Specification of Explosion-Proof Type EExmIIT4 Protecion +10% Voltage Range AC = 4.4VA, DC = 5W Power Consumption Class F Insulation Class
HSV310-08
HSV320-08
24 193
136.5
27
45
Order Information:
Flow features:
HSV - 310 - 08 - AC220 - L Model
Port Size:08:1/4"
310:Single Solenoid,5/2 way 320:Double Solenoid,5/2 way
Blank: DIN Connector L: LED E: Explosion-Proof DC12V DC24V AC24V,50/60Hz AC110V,50/60Hz AC220V,50/60Hz
G1/4"
27
45
G1/4"
G1/4"
G1/4"
G1/4"
G1/4" 17.5
69
4
4
69
4
24
Φ20*1.4 Φ5.5
Φ20*1.4
Φ20*1.4 Φ5.5
Φ20*1.4
28
HT1000R E/P Positioner
d
Rotary Type Dimension: HT-1000R 221
8 9
2-M8X1.25P
91.8
4-M8X1.25P
45
90° 80.2
50
27
43.5 26.5
CONDUIT ENTRY PF 1/2”
166.5
122
32.5
132
OUT2. PT(NPT) 1/4” 113.5
45
Linear Type Dimension: HT-1000L 224.3 6
2-M8X1.25P
4-M8X1.25P
45
91.8
CONDUIT ENTRY PF 1/2”
166.5
122
50
132.3
45
The Electro-Pneumatic Valve Positioner stroke accurately by DV 4~20mA current signal being input from controller. It change the current signal into air pressure to contorl the pneumaitc actuator ,so as to control the opening of the valve. This product is convenient to change between direct action and back action, or change between spring return and double acting. It has the features of low air consumption, easy to operate the Zero Adjust and Span Adjust, quick acting and simple to connect the Feedback Lever. HT-1000R(rogary) and HT-1000L(linear) all can select and install the DC 4~20 mA Feedback Unit. ● ● ● ● ● ● ● ●
There is no vibration in the range of 5-200 HZ. Can set 1/2 Split Range with simply operate ,do not need to change part. Zero & Span adjustment process is simply. Convenient to change between direct action and back action, or change between spring return and double acting. Feedback lever connection is easy. Acting fast and accurately. It is economical due to less air-consumption. Small pneumatic actuator can use the orifice of Pilot valve to avoid vibration.
MO-Manual Override The HTXL series de-clutch override gear box were specially designed used for butterfly valve, ball valve and plug valve together with pneumatic actuators. This device allows for manual operation during installation, system testing and in the event of a supply air-failure. The HTXL Series mount directly to many of the most popular rack and pinion style actuators on the market, and does not require a bracket between the pneumatic actuator and de-clutch override. The units come complete with a coupler that connects the pneumatic actuator to the valve.
1. Compact and simply design, light in weight. Model 2. Manufactured with cast iron housing. 3. IS0-5211 direct mount patterns. HTXL26 4. Easy for customer to choose relative position between gear operator and HTXL38 valve, with two keyway apart 90~ in the inner hole of worm gear. HTXL54 5. Easy to realize the manual drive or the pneumatic drive with the place-pin. HTXL80 6. Weatherproof is IP65. HTXL78A 7. Output torque ranges from 300 to 22100N.m.
Model
d
b
t
HTXL26:1
22 26
6 8
25.4 29.3
38
10
41.3
38
10
41.3
48 48
14 14
51.8 51.8
60
18
64.4
60
18
64.4
165
M20
HTXL98:1
80 80
18 18
84.4 84.4
165
M20
HTXL100:1
100
20
105.3
254
HTXL118:1
120 180
32 45
129.3 196
356 483
HTXL38:1 HTXL54:1 HTXL80:1 HTXL78:1
D1 70 125 140
F
(N.m)
(N.m)
(Kg)
26:1 38:1
70 60
300 550
7.3 11.8
54:1
120
1200
17.3
80:1
140
2000
35
78:1 HTXL98 98:1
200 300
3600 9000
48.2 156
HTXL100 100:1
400
13000
190
HTXL118 118:1
900
22100
540
D2
G
A
H
E
70
M8
70 100
99
50.5
102
M10
110
117
65
140
M16
130
118
85
165
M20
156
148
124
220
150
142
230
195
229
165 Φ22
M16
300
195
258
M30 M36
Φ445 Φ600
250 275
391 390
M8 M12 M16
D3
Gear Input Torque Output Torque Weight Ratio
D4
J
K
L
B
C
D
70
Φ9
Φ200
155
160
145
110
102
Φ12
Φ200
195
195
175
140
140
Φ18
Φ300
205
235
215
180
165
Φ22
Φ400
245
320
298
250
Φ600 Φ800
265 410
360 550
340 530
285 460
254 Φ18
Φ800
430
605
585
520
356 Φ32 483 Φ39
Φ1000 550 Φ600 600
900 870 1050 900
800 850
70
I Φ9
125 Φ14 140 Φ18 165 Φ22
4-3
Limit Switchbox - Position Monitoring Switchbox HTM ALS Series position monitoring switchbox a rotary position indication device and is designed to integrate with valve or NAMUR rotary pneumatic actuator with a variety of mounting options, internal switches, sensors and configurations.
Order Information: ALS-
A Weather-Proof Series100,200,300,400,500
-
Explosion-Proof Series400,500
1 Switch(sensor)Type: 1.Mechanical Type 2.Proximity(Inductive)Type 3.Magnet Type
-
M2 M2:2SPDT M3:3SPDT M4:4SPDT M5:2DPDT PP:P&F PA:2 or 3 QA:2 o r3
Position Monitoring Switchbox: ALS-500 (AL or SS)
Model
ALS-100
ALS-200
ALS-300
ALS-400
Weather Proof
---
CSA IP67 NEMA 4,4X
IP67 NEMA 4,4X
IP66
IP66
Exdll CT6
Exdll CT6, DIPA21 TA, T6 IECEx, ATEX
G1/2", G3/4", 1/2"NPT 3/4"NPT, M20x1.5
G1/2", G3/4", 1/2"NPT 3/4"NPT, M20x1.5
M2:2SPDT M3:3SPDT M4:4SPDT M5:2DPDT
M2:2SPDT M3:3SPDT M4:4SPDT M5:2DPDT
Explosion Proof
---
---
---
M20x1.5
G1/2", 1/2"NPT M20x1.5, M16x1.5
G1/2", 1/2"NPT M20x1.5, M16x1.5
-25°C~85°C
Temperature Range Cable Entry Terminal Stripe
8~14
Position lndicator
0~90° Open-Yellow Close-Red 5A/16A 125~250VAC
(Mech.Sw itches)Type
M2:2SPDT M3:3SPDT M5:2DPDT
M2:2SPDT M3:3SPDT M4:4SPDT M5:2DPDT
M2:2SPDT
DC 24V (10~30VDC), <=150mA PP:P&F (NAMUR) Exia‖CT6 PA:2(wires) or 3(wires)
(Proximity Sensor)Type
5~240VAC/DC, <=300mA
(Magnet Sensor)Type (Expand options)Type
QA:PA:2(wires) or 3(wires) ---
---
4-20mA (Valve position feedback )
---
Outline Dimension: ALS-100 Classic Type 124 CL
φ5
80
CLOSE
CLOSE
117.7
CLOSE
32 4 25
φ50 CLOSE
M20x1.5 φ9.5
4
4-4
CLOSE
56.7
SE
4-M6
Limit Switchbox - Position Monitoring Switchbox ALS-200 ALS-200Mini MiniType Type 68
112 G1/2″
CL
SE
44
CLOSE
10
CLOSE
CLOSE
4-M6
φ5
4
17
CLOSE
CLOSE
88
94
φ50
4
φ9.5
A
ALS-300 Functional Type 57.1 CLOSED
CL
ED
CLOSED
57.1
110
131
CLOSED
2-M8
38
CLOSED
4
20
φ9.5
27
2-G1/2"
8
CLOSED
φ5
4
4-M8
53
79
132
ALS-400 Explosion Proof Type 45 N
CLOSED
O
57.1
148
142
CLOSED
20
CLOSED
4-M8
φ9.5
4
27 20
2-G3/4"
φ5
57.1
133.5
4
ALS-500 Explosion Proof Type
5 9.5
4
2-G3/4"
26.8 19.8
57.1
112.1
137
49.7
49.7
57.1
4-M8
127.6
4
ALS-200D Temperature Range
-40℃~85℃
Position Indicator 0~90°
Sensor Type
Magent type
Working Voltage
5~240VAC/DC
Rared Operating Distance
1~6mm
Working Current
0~300mA
Switching Element Function NO (Optional NC) Rated Power Output Type
2-Wire
Switching Frequency
0~4.8KHz
10W
Protection Degree IP67
The ALS-200D double sensor converts the end or middle positions of pneumatic actuators into electrical signals. It combines easy assembly with minimal components and is provided for pneumatic actuators. The flexible set system allows an adaptation to all sizes of actuators according to NAMUR.
Air Filter Regulator - HAFR50 Air Filter Regulator Air Filter Regulator Feature: ●Superior regulation characteristics. ●Rugged and corrosion-resistant construction ●Excellent stability and repeatability. ●Self-Relieving. ●Low drop at high flow. ●Intergral,self cleaning filter. ●Several mounting options. Technical Information: Sensitivity: Flow Capacity: Exhaust Capacity(5psi above,20psi set point)
25.4mm water column 565LPM 2.8LPM
Effect of Supply Pressure Variation(25psi) On Outlet Pressure: Max. Input Pressure: Output Pressure Range: Filtration: Temperature Range: Total Air Consumption at Max. Output: Port Size: Outline Dimension: Weight:
< 0.2PSI(0.01bar) 1700KPa 0-200KPa; 0-400KPa; 0-800Kpa 5um -18°C to 71°C 2.8LPM 1/4”NPT 81 x 80 x 184mm 0.8 Kg(1.76 Lbs)
Material of Construction:
1.Body:Die-Cast Aluminum with Vinyl Paint 2.Diaphragm:Buna-N Elastomer with Polyester Fabric.
Mounting:
Bracket for Pipe and Panel
BAR
Regulated Press]ure Vs. Flow
6.2 5.5
0-800Kpa
4.8
184
4.1 3.4
IN
OUT
2.8
NPT1/4
0-400Kpa
OUT
2.1 1.4
0-200Kpa
0.7
81
4-6
0 LPM 0 FLOW
Model
Part Number
HAFR-50
960-067-000 960-068-000 960-069-000
142
283
425
566
Pressure Range 0-200KPa(0-30psig) 0-400KPa(0-60psig) 0-800KPa(0-120psig)
708
Air Filter Regulator - HAFR30 Air Filter Regulator Air Filter Regulator Model
HAFR-30
Port No. Port Size
8A PT 1/4
10A PT 3/8
Medium
Air
Operating Pressure Range Proof Pressure Effective Orifice Regulation Pressure Range
0 ~ 9.9 kgf/cm2(0 ~ 0.99Mpa) 15 kgf/cm2(1.5Mpa) 34 mm2 32 mm2 0.5 ~ 8.5 kgf/cm2(0.05 ~ 0.99Mpa) -5 ~ +60째C
Ambient Temperature
Std.:5um,Option:40um Pressure Gauge, Bracket
Filtration Accessories
Order Information HAFR30 Model
-
8A
BSP
Port No. D:Auto Drain 8A: PT 1/4 10A: PT 3/8
Valve Conn. Blank:PT BSP:BSP NPT:NPT
Secondary Pressure
Primary Pressure
Flow l/min(AIR)
Secondary Pressure
Primary Pressure
Drain Outlet
Flow l/min(AIR)
4-7
Taiwan Head Office 8F., No.201, Sec. 2, Tiding Blvd., Neihu District, Taipei City 114, Taiwan R.O.C.