temperature probes Bare Thermoresistive Sensor SR PLATINUM TEMPERATURE SENSOR Sheath - thin film. Leads - radial ø0.25 mm. Electroplated - Ag5%Pd. Accuracy class 'B' or 'A'. Sensor view
Sensor code
SRR
Technical specifications
Temperature range
H [mm]
RO [Ω]
3 ± 0.2
1.3 ± 0.2
1 × 100
T1
-50...400 °C
T11
-50...600 °C
2 ± 0.2
1.3 ± 0.2
1 × 100
T1
-50...400 °C
T11
-50...600 °C
5 ± 0.2
2 ± 0.2
1.3 ± 0.2
1 × 100
T1
-50...400 °C
T11
-50...600 °C
2.3 ± 0.2
2 ± 0.2
1.3 ± 0.2
1 × 100
T1
-50...400 °C
T11
-50...600 °C
1.3 ± 0.2
1 × 1000
T1
-50...400 °C
T11
-50...600 °C
L [mm]
B [mm]
2100
10 ± 0.2
2101
10 ± 0.2
2103 2105 2141
10 ± 0.2
2 ± 0.2
SPECIAL SENSORS 2.5 ± 0.2
2106
5 ± 0.2
2 ± 0.2
1.3 ± 0.2
1 × 50
T1
-50...400 °C
1.15
1.3 ± 0.2
1 × 100
T1
-50...400 °C
PLATINUM TEMPERATURE SENSOR Sheath - thin film. Leads - axial ø0.25 mm. Electroplated - Ag5%Pd. Accuracy class 'B' or 'A'. Sensor view
Sensor code
2105
SRA
Technical specifications L [mm]
B [mm]
H [mm]
RO [Ω]
2.3 ± 0.2
2 ± 0.2
1.4 ± 0.3
1 × 100
Temperature range
T1
-50...400 °C
PLATINUM TEMPERATURE SENSOR Sheath - thin film (SMD). Leads - for surface mounting. Accuracy class 'B' Sensor view
Sensor code
2000
SRM
Technical specifications L [mm]
B [mm]
H [mm]
RO [Ω]
3 ± 0.2
1.5 ± 0.2
0.5 ± 0.1
1 × 100
Temperature range
T12
-10...100 °C
PLATINUM TEMPERATURE SENSOR Sheath - thin film. Leads - radial ø0.25 mm. Electroplated - Ag5%Pd. Accuracy class 'B' or 'A'. Sensor view
Sensor code
SRC
Technical specifications
Temperature range
L [mm]
ø [mm]
RO [Ω]
2100
12 ± 1
4.5 ± 0.2
1 × 100
T1
-50...400 °C
T11
-50...600 °C
2102
12 ± 1
3 ± 0.2
1 × 100
T1
-50...400 °C
T11
-50...600 °C
2103
6± 1
2 ± 0.2
1 × 100
T1
-50...400 °C
T11
-50...600 °C
2202
12 ± 1
3 ± 0.2
2 × 100
T1
-50...400 °C
T11
-50...600 °C
WIRE-WOUND COPPER TEMPERATURE SENSOR Sheath - stainless steel 1.4301. Sensor view
Sensor code
SRC Technical specifications
Temperature range
L [mm]
ø [mm]
RO [Ω]
3100
25 ± 1
4 ± 0.2
1×
50
T9
-50...200 °C
3101
32 ± 1
5 ± 0.2
1×
50
T9
-50...200 °C
3110
40 ± 1
4 ± 0.2
1 × 100
T9
-50...200 °C
3111
80 ± 1
5 ± 0.2
1 × 100
T9
-50...200 °C
3201
32 ± 1
5 ± 0.2
2×
T9
-50...200 °C
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
50
COMECO reserves the right of changing specifications without prior notice!
2155
temperature probes
WIRE-WOUND PLATINUM TEMPERATURE SENSOR Sheath - ceramic. Leads - pure platinum. Accuracy class 'B' or 'A'. Sensor code
ø [mm]
Leads ø [mm]
RO [Ω]
Temperature range
4301 (8301)
30 ± 0.5
4.5 - 0.03
0.40
1(2) × 100
T2
-200...850 °C
4302 (8302)
30 ± 0.5
3.8 - 0.03
0.40
1(2) × 100
T2
-200...850 °C
4251 (8251)
25 ± 0.5
3.2 - 0.03
0.40
1(2) × 100
T2
-200...850 °C
4252 (8252)
25 ± 0.5
3.0 - 0.03
0.40
1(2) × 100
T2
-200...850 °C
4253 (8253)
25 ± 0.5
2.8 - 0.03
0.40
1(2) × 100
T2
-200...850 °C
4254 (8254)
25 ± 0.5
2.4 - 0.03
0.40
1(2) × 100
T2
-200...850 °C
4255 (8255)
25 ± 0.5
1.5 - 0.03
0.27
1(2) × 100
T2
-200...850 °C
4201 (8201)
20 ± 0.5
2.0 - 0.03
0.27
1(2) × 100
T2
-200...850 °C
4151 (8151)
15 ± 0.5
4.5 - 0.03
0.40
1(2) × 100
T2
-200...850 °C
4152 (8152)
15 ± 0.5
3.2 - 0.03
0.40
1(2) × 100
T2
-200...850 °C
4153 (8153)
15 ± 0.5
3.0 - 0.03
0.40
1(2) × 100
T2
-200...850 °C
4154 (8154)
15 ± 0.5
2.8 - 0.03
0.40
1(2) × 100
T2
-200...850 °C
4155 (8155)
15 ± 0.5
2.4 - 0.03
0.40
1(2) × 100
T2
-200...850 °C
4156 (8156)
15 ± 0.5
2.0 - 0.03
0.27
1(2) × 100
T2
-200...850 °C
4157 (8157)
15 ± 0.5
1.5 - 0.03
0.27
1(2) × 100
T2
-200...850 °C
4158 (8158)*
15 ± 0.5
1.2 + 5%
0.27
1(2) × 100
T2
-200...850 °C
4159 (8159)*
15 ± 0.5
0.9 + 5%
0.15
1(2) × 100
T2
-200...850 °C
4150 (8150)*
15 ± 0.5
0.8 + 5%
0.15
1(2) × 100
T2
-200...850 °C
4101 (8101)*
10 ± 0.5
1.6 - 0.03
0.27
1(2) × 100
T2
-200...850 °C
4102 (8102)*
10 ± 0.5
1.2 + 5%
0.27
1(2) × 100
T2
-200...850 °C
4103 (8103)*
10 ± 0.5
0.8 + 5%
0.15
1(2) × 100
T2
-200...850 °C
4081 (8081)*
8 ± 0.5
1.5 - 0.03
0.27
1(2) × 100
T2
-200...850 °C
4061 (8061)*
6 ± 0.5
2.0 + 3%
0.27
1(2) × 100
T2
-200...850 °C
4041 (8041)*
4 ± 0.3
4.5 + 3%
0.40
1(2) × 100
T2
-200...850 °C
Ordering code
SR - G2.G3.G11
Code Feature or option
Technical specifications L [mm]
Code values
Variant
R, A, M, C
G2
Sensor (1)
code (from tables above)
G3
Temperature range (1)
T1 - -50…400 °C, T2 - -200…850 °C, T9 - -50…200 °C, T11 - 50…600 °C, T12 - 10…100 °C
G11
Accuracy class
A - 'A', B - 'B'
(1)
Do not code if there is only one possible for the selected variant.
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Sensor view
SRC
temperature probes Thermocouples without Sheath ST (Bare T/Cs and ceramic insulated T/Cs)
BASE METAL
Variant Material Wire diameter ('ø') [mm] Maximum temperature [°C] Isolation
J
K
Fe-CuNi
NiCr-Ni
1.0 800
1.5 800
E
NiCr-CuNi 0.5 1.0 1.5 3.0 1.5 3.0 800 1000 1100 1200 800 900 1- , 2-, or 4-hole steatite ceramic beads (max. 1200 °C) (option)
L (GOST) NiCr-CuNi 1.2 3.2 700 800
NOBLE METAL Variant
S
Material Wire diameter ('ø') [mm] Maximum temperature [°C] Isolation
Ordering code
B
C Wo5%Re-Wo26%Re 0.5 2320 none
ST - G4.(G6) - #1.#2
Code Feature or option
R
Pt10%Rh-Pt Pt13%Rh-Pt Pt30%Rh-Pt6%Rh 0.35 0.5 0.35 0.5 0.35 0.5 1600 1600 1600 1600 1800 1800 2- or 4-hole alumina ceramic rod (up to 1500, 1600, or 1700 °C) (option)
Variant
Code values J, K, E, L, S, R, B, C
(1)
G4
Wire diameter 'ø' [mm]
G6
Length [m]
length
0.35, 0.5, 1.0, 1.2, 1.5, 3.0, 3.2
#1
Isolation (1)
X - none, CZ - ceramic beads (2), C1 - ceramic rod '610' up to 1500 °C, C2 - ceramic rod '710' up to 1600 °C and up to 1 m, C3 - ceramic rod '799' up to 1700 °C
#2
Packing
X - none, R - on rolls
(1)
COMECO reserves the right of changing specifications without prior notice!
Applicable for the selected variant (2) Up to 25 m; with 1, 2, or 4 holes, depending on the variant
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
Insulation - Teflon®, silicone, fiberglass, or ceramic (see table notes) Wire leads - Cu, Ni, or Ag (see table notes)
MAXIMUM TEMPERATURE
TSEx DESIGN
RTD ELEMENT WITH LEADS
1
200 °C
INSULATION
element
LEADS
leads
outer none
DESIGN 1 (TSE1)
Teflon®
Teflon®
Teflon® silicone
2
400 °C 550 °C
3
400 °C 600 °C 800 °C
ceramic, cement
ceramic beads
4
400 °C 600 °C 800 °C
ceramic, cement
ceramic rod
L = 100 … 2000 mm
DESIGN 2 (TSE2)
SS tube, cement
glass sleeves
none glass
type
Cu stranded 0.14(22) mm2 Cu, Ni solid 0.5 mm
wires 2, 3, 4*
2x2
2, 3, 4*
2x2
2, 3, 4*
2x2
2, 3, 4*
2x2
2, 3, 4*
2x2
-
Cu, Ni, Ag solid 0.5 mm
2, 3, 4
2x2
-
Cu, Ni, Ag solid 0.5 mm
2, 3, 4
2x2
RTD element: (simplex or duplex) Pt50 (RB), Pt100 (RD), Pt500 (RF), Pt1000 (RG) Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Minimum mounting hole diameter ('d'): Wire leads
L = 100 … 2000 mm
DESIGN 3 (TSE3)
Design
2
3
4
no outer insulation
3 mm
4 mm
1
Teflon® outer insulation
4 mm
5 mm
silicone outer insulation
5 mm
6 mm
6 mm
2
no outer insulation glass outer insulation
4 mm 5 mm
5 mm
6 mm
6 mm
6 mm
3
5 mm
4
6 mm
5 mm
Outer diameter: d1 ≤ d - 0.5 mm
DESIGN 4 (TSE4)
Wire material: Cu (up to 450 °C), Ni, or Ag Insulation material: - silicone or Teflon® (max. 200 °C) - glass fiber (max. 550 °C) - SS 316 (max. 850 °C) - ceramic 610 (max. 1500 °C) Lead termination: - free (flying) leads, 10...15 mm non-insulated - ceramic base and screw terminals for heads w/ 20 mm mounting distance - ceramic base and screw terminals for heads w/ 33 mm mounting distance
L = 100 … 1000 mm * Please contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
L = 100 … 2000 mm
temperature probes
Ordering code TSE(1,2,3,4) - G1G2.G3.G4.G8.G11.G12.G13 - #1.#2 Code Feature or option
Code values
G1
Number of RTD sensors
1, 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000
G3
Temperature range (1)
T1 - -50…400 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C (2)
G4
Mounting hole diameter 'd' (1)
3 - ≥ 3 mm (5), 4 - ≥ 4 mm, 5 - ≥ 5 mm, 6 - ≥ 6 mm, 7 - > 6 mm
G8
Lead length 'L' [mm]
100…2000 (1)
G11
Accuracy class
A - 'A', B - 'B', C - '2xB'
G12
Number of wires (1)
2, 3, 4 (5)
G13
Wire material (1)
CU - copper (3), NI - nickel, AG - silver
#1
Additional outer lead insulation
X - none, I - mounted (4)
#2
Lead termination options
X - none (free leads), M - ceramic base and screw terminals for heads w/ 20 mm mounting distance, B - ceramic base and screw terminals for heads w/ 33 mm mounting distance
(1)
Applicable for the selected design Up to 550 °C for TSE2! Not applicable for temperatures above 450 °C! (4) Only for TSE1 and TSE2! (5) Contact COMECO!
(2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
(MI**) RTD CABLE PROBE FOR FREE MOUNTING
TSAx
Sheath - stainless steel (see table notes) Cable - see table notes
SENSITIVE ELEMENT
1 x Pt (RB,RD,RF,RG)
STRAIGHT-TUBE DESIGN (TSA)
2 x Pt (RB,RD,RF,RG) n = 20 … 200 mm
k = 1 … 10 m
1 x Cu (RH, RK) 2 x Cu (RH, RK)
DESIGN WITH ANGLED TERMINATION (TSAL)
CABLE TYPE
TEMPERATURE RANGE
SLSL, TSL, TT, YY, UU, YU
T9 T1*
GLGL
T7 T8
-50...200 °C -50...400 °C
DIMENSIONS d [mm]
wires
3*
2, 3*
4, 4.5**
2, 3*
5
2, 3*
6
2, 3, 4*
8
2, 3, 4
0...200 °C 0...400 °C
TT
T22 -200...200 °C
6, 8
SLSL, TSL, YY, UU, YU
T9
-50...200 °C
GLGL, TT
T7
0...200 °C
2x2, 2x3*
5*
2, 3*
6
2, 3, 4*
8
2, 3, 4
6, 8
2x2, 2x3*
1 x PTC (RP, RQ)
SLSL, TSL, YY, UU, YU
T12
-50...100 °C
6
2, 3
2 x PTC (RP, RQ)
GLGL, TT
T19
0...100 °C
8
2x2
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Applicable cables: n = 20 … 200 mm
k = 1 … 10 m
Probe design Temp. range T12, T19
BENDED-TUBE DESIGN (TSAB)
TSA, TSAB
TSAL
all
all
T7, T9 T22
no PUR, no PVC TT
TT, SLSL, TSL
T1, T8
GLGLP
no PUR, no PVC
Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes)
Cable connector: 4-pin (C3) (see Appendix - Connectors) n = 20 … 200 mm m = 30 ... 200 mm
k = 1 … 10 m * Please contact COMECO! ** Available only for TSAL!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance)
temperature probes
Ordering code
TSA(L,B) - (MI -(1)) G1G2.G3.G4.G6.G7.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option
Code values
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP - PTC 1k, RQ - PTC 2k
G3
Temperature range
T1 - -50…400 °C, T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T12 - 50…100 °C, T19 - 0…100 °C, T22 - -200…200 °C
G4
Diameter 'd' [mm]
G6
Probe length 'n' [mm]
regular design
4, 5, 6, 8
MI design
3 (5), 4.5, 6, 8 20…200
(2)
G7
Probe length 'm' [mm]
G8
Cable length 'k' [m] and type
G10
Sheath material (wetted parts)
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
G11
Accuracy class
X - none (3), A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (5)
G14
Tip shape
X - standard closed, N - narrowed (4), P - pitted (4)
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only)
Options
X - none, OV - vibration proof (MgO or Silicone filled) (4), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface (4)
#1
30…200 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (5), 1PV…10PV - PVC
(1)
Available only for TSAL! Only for TSAB! For non-Pt sensors (4) Only for non-MI (regular) design! (5) Contact COMECO!
(2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
(MI**) T/C CABLE PROBE FOR FREE MOUNTING
TSAx
Sheath - stainless steel (see table notes) Cable - see table notes
SENSITIVE ELEMENT
CABLE TYPE
DIMENSIONS
TEMPERATURE RANGE
d [mm]
wires
Regular Design
STRAIGHT-TUBE DESIGN (TSA) 1xK
n = 20 … 200 mm
k = 1 … 10 m
1 x J, 1xT
SLSL, TSL, YY, UU, YU
T9 T1*
GLGL, TT, SFSF
T7 T8
-50...200 °C -50...400 °C 0...200 °C 0...400 °C
T4*
0...800 °C
SLSL, TSL, YY, UU, YU
T9 T1*
-50...200 °C -50...400 °C
GLGL, TT, SFSF
T7 T8
4, 5, 6, 8
2
4, 5, 6, 8
2
3, 4.5, 6, 8
2
3, 4.5, 6, 8
2
0...200 °C 0...400 °C
MI Design **
DESIGN WITH ANGLED TERMINATION (TSAL)
SLSL, TSL, YY, UU, YU
T9 T1*
GLGL, TT, SFSF
T7 T8
-50...200 °C -50...400 °C
1 x N, 1xE
0...200 °C 0...400 °C
T4*
0...800 °C
SLSL, TSL, YY, UU, YU
T9 T1*
-50...200 °C -50...400 °C
GLGL, TT, SFSF
T7 T8
1xT 0...200 °C 0...400 °C
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9), 1.4841 (M5), 2.4816 (M8) k = 1 … 10 m
BENDED-TUBE DESIGN (TSAB)
Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) - SFSF (mineral fiber, max. 1000 °C ambient temperature) Applicable cables: Probe design Temp. range T7, T9 T1, T8 T4
n = 20 … 200 mm m = 30 ... 200 mm
k = 1 … 10 m
TSA, TSAB
TSAL
no PUR, no PVC
all
GLGLP, SFSF
no PUR, no PVC
SFSF
GLGLP, SLSL*, TSL*
Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors)
* Please contact COMECO! ** Available only for TSAL!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
n = 20 … 200 mm
temperature probes
Ordering code
TSA(L,B) - (MI -(1)) G2.G3.G4.G6.G7.G8.G10.G11.G14.G15 - #1
Code Feature or option
Code values regular design
J - type "J", K - type "K", T - type "T"
G2
Thermocouple
G3
Temperature range
G4
Diameter 'd' [mm]
G6
Probe length 'n' [mm]
20…200
G7
Probe length 'm' [mm] (2)
30…200
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1MF…10MF - mineral fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1PV…10PV - PVC
G10
Sheath material (wetted parts)
G11
Accuracy class
1 - '1' (4), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled) (3), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface (3)
MI design
E - type "E", N - type "N", T - type "T" T1 - -50…400 °C, T4 - 0…800 °C (4), T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C
regular design MI design
4 (4), 5, 6, 8 3, 4.5, 6, 8
regular design
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
MI design
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404
(1)
Available only for TSAL! Only for TSAB! Only for non-MI (regular) design! (4) Contact COMECO!
(2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
(MI**) RTD CABLE PROBE FOR FREE MOUNTING
TSAx
Sheath - stainless steel (see table notes) Cable - see table notes
SENSITIVE ELEMENT
1 x Pt (RB,RD,RF,RG)
STRAIGHT-TUBE DESIGN (TSA)
2 x Pt (RB,RD,RF,RG) n = 20 … 200 mm
k = 1 … 10 m
1 x Cu (RH, RK) 2 x Cu (RH, RK)
DESIGN WITH ANGLED TERMINATION (TSAL)
CABLE TYPE
TEMPERATURE RANGE
SLSL, TSL, TT, YY, UU, YU
T9 T1*
GLGL
T7 T8
-50...200 °C -50...400 °C
DIMENSIONS d [mm]
wires
3*
2, 3*
4, 4.5**
2, 3*
5
2, 3*
6
2, 3, 4*
8
2, 3, 4
0...200 °C 0...400 °C
TT
T22 -200...200 °C
6, 8
SLSL, TSL, YY, UU, YU
T9
-50...200 °C
GLGL, TT
T7
0...200 °C
2x2, 2x3*
5*
2, 3*
6
2, 3, 4*
8
2, 3, 4
6, 8
2x2, 2x3*
1 x PTC (RP, RQ)
SLSL, TSL, YY, UU, YU
T12
-50...100 °C
6
2, 3
2 x PTC (RP, RQ)
GLGL, TT
T19
0...100 °C
8
2x2
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Applicable cables: n = 20 … 200 mm
k = 1 … 10 m
Probe design Temp. range T12, T19
BENDED-TUBE DESIGN (TSAB)
TSA, TSAB
TSAL
all
all
T7, T9 T22
no PUR, no PVC TT
TT, SLSL, TSL
T1, T8
GLGLP
no PUR, no PVC
Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes)
Cable connector: 4-pin (C3) (see Appendix - Connectors) n = 20 … 200 mm m = 30 ... 200 mm
k = 1 … 10 m * Please contact COMECO! ** Available only for TSAL!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance)
temperature probes
Ordering code
TSA(L,B) - (MI -(1)) G1G2.G3.G4.G6.G7.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option
Code values
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP - PTC 1k, RQ - PTC 2k
G3
Temperature range
T1 - -50…400 °C, T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T12 - 50…100 °C, T19 - 0…100 °C, T22 - -200…200 °C
G4
Diameter 'd' [mm]
G6
Probe length 'n' [mm]
regular design
4, 5, 6, 8
MI design
3 (5), 4.5, 6, 8 20…200
(2)
G7
Probe length 'm' [mm]
G8
Cable length 'k' [m] and type
G10
Sheath material (wetted parts)
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
G11
Accuracy class
X - none (3), A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (5)
G14
Tip shape
X - standard closed, N - narrowed (4), P - pitted (4)
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only)
Options
X - none, OV - vibration proof (MgO or Silicone filled) (4), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface (4)
#1
30…200 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (5), 1PV…10PV - PVC
(1)
Available only for TSAL! Only for TSAB! For non-Pt sensors (4) Only for non-MI (regular) design! (5) Contact COMECO!
(2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
(MI**) T/C CABLE PROBE FOR FREE MOUNTING
TSAx
Sheath - stainless steel (see table notes) Cable - see table notes
SENSITIVE ELEMENT
CABLE TYPE
DIMENSIONS
TEMPERATURE RANGE
d [mm]
wires
Regular Design
STRAIGHT-TUBE DESIGN (TSA) 1xK
n = 20 … 200 mm
k = 1 … 10 m
1 x J, 1xT
-50...200 °C -50...400 °C
SLSL, TSL, YY, UU, YU
T9 T1*
GLGL, TT, SFSF
T7 T8
0...200 °C 0...400 °C
T4*
0...800 °C
SLSL, TSL, YY, UU, YU
T9 T1*
-50...200 °C -50...400 °C
GLGL, TT, SFSF
T7 T8
4, 5, 6, 8
2
4, 5, 6, 8
2
3, 4.5, 6, 8
2
3, 4.5, 6, 8
2
0...200 °C 0...400 °C
MI Design **
DESIGN WITH ANGLED TERMINATION (TSAL)
SLSL, TSL, YY, UU, YU
T9 T1*
GLGL, TT, SFSF
T7 T8
-50...200 °C -50...400 °C
1 x N, 1xE
0...200 °C 0...400 °C
T4*
0...800 °C
SLSL, TSL, YY, UU, YU
T9 T1*
-50...200 °C -50...400 °C
GLGL, TT, SFSF
T7 T8
1xT 0...200 °C 0...400 °C
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9), 1.4841 (M5), 2.4816 (M8) k = 1 … 10 m
BENDED-TUBE DESIGN (TSAB)
Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) - SFSF (mineral fiber, max. 1000 °C ambient temperature) Applicable cables: Probe design Temp. range T7, T9 T1, T8 T4
n = 20 … 200 mm m = 30 ... 200 mm
k = 1 … 10 m
TSA, TSAB
TSAL
no PUR, no PVC
all
GLGLP, SFSF
no PUR, no PVC
SFSF
GLGLP, SLSL*, TSL*
Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors)
* Please contact COMECO! ** Available only for TSAL!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
n = 20 … 200 mm
temperature probes
Ordering code
TSA(L,B) - (MI -(1)) G2.G3.G4.G6.G7.G8.G10.G11.G14.G15 - #1
Code Feature or option
Code values regular design
J - type "J", K - type "K", T - type "T"
G2
Thermocouple
G3
Temperature range
G4
Diameter 'd' [mm]
G6
Probe length 'n' [mm]
20…200
G7
Probe length 'm' [mm] (2)
30…200
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1MF…10MF - mineral fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1PV…10PV - PVC
G10
Sheath material (wetted parts)
G11
Accuracy class
1 - '1' (4), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled) (3), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface (3)
MI design
E - type "E", N - type "N", T - type "T" T1 - -50…400 °C, T4 - 0…800 °C (4), T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C
regular design MI design
4 (4), 5, 6, 8 3, 4.5, 6, 8
regular design
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
MI design
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404
(1)
Available only for TSAL! Only for TSAB! Only for non-MI (regular) design! (4) Contact COMECO!
(2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes SCREW-IN CABLE PROBE
TSAGx
Sheath - stainless steel (see table notes) Cable - see table notes
SENSITIVE ELEMENT
CABLE TYPE
TEMPERATURE RANGE
DIMENSIONS d [mm]
wires
RTD Design
STRAIGHT DESIGN WITH WELDED CONNECTION (TSAG)
1 x Pt (RB,RD,RF,RG) 2 x Pt (RB,RD,RF,RG) 1 x Cu (RH, RK)
n = 15 … 200 mm k = 1 … 10 m
STRAIGHT DESIGN WITH MOVABLE CONNECTION (TSAG2)
2 x Cu (RH, RK)
-50...200 °C -50...400 °C
4, 5
2, 3*
6
2, 3, 4*
0...200 °C 0...400 °C
8
2, 3, 4
SLSL, TSL, YY, UU, YU
T9 T1*
GLGL, TT
T7 T8
TT
T22 -200...200 °C
SLSL, TSL, YY, UU, YU
T9
-50...200 °C
GLGL, TT
T7
0...200 °C
2x2,
6, 8
2x3*
5*
2, 3*
6
2, 3, 4*
8
2, 3, 4 2x2,
6 ,8
2x3*
1 x PTC (RP, RQ)
SLSL, TSL, YY, UU, YU
T12
-50...100 °C
6
2, 3
2 x PTC (RP, RQ)
GLGL, TT
T19
0...100 °C
8
2x2
1 x K,
SLSL, TSL, YY, UU, YU
T9 T1*
-50...200 °C -50...400 °C
GLGL, TT, SFSF
T8 T4 T3*
0...400 °C 0...800 °C 0...850 °C
5, 6, 8
2
1 x J,
SLSL, TSL, YY, UU, YU
T9 T1*
-50...200 °C -50...400 °C
1xT
GLGL, TT, SFSF
T8 T4*
0...400 °C 0...800 °C
5, 6, 8
2
Thermocouple Design
1 x N, 1xE m = 30 … 100 mm k = 1 … 10 m
n = 10 … 200 mm
ANGLED DESIGN WITH WELDED CONNECTION (TSAGL)
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) - SFSF (mineral fiber, max. 1000 °C ambient temperature) Applicable cables:
k = 1 … 10 m
ANGLED DESIGN WITH MOVABLE CONNECTION (TSAGL2)
TSAG, TSAG2 all no PUR, no PVC TT GLGLP, SFSF SFSF
TSAGL, TSAGL2 all TT, SLSL, TSL no PUR, no PVC GLGLP, SFSF
Tip shape: - RTD: standard, narrowed, pitted - T/C: standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors) Available threads and HEX sizes: n = 10 … 200 mm m = 50 … 100 mm
k = 1 … 10 mm
G SW
M6
M8
10
10
M10 1/8" 12(13)
* Please contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
M12 1/4" 14
M14 17
M16 3/8" 19
M18 22
M20 1/2" 24
COMECO reserves the right of changing specifications without prior notice!
n = 15 … 200 mm
Probe design Temp. range T12, T19 T7, T9 T22 T1, T8 T3, T4
temperature probes
Ordering code
TSAG(2,L,L2) - G1G2.G3.G4.G6.G7.G8.G9.G10.G11.G12.G14.G15 - #1
Code Feature or option
Code values
G1
Number of sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP -PTC 1k, RQ - PTC 2k, J - T/C type "J", K - T/C type "K", T - T/C type "T"
G3
Temperature range
T1 - -50…400 °C, T3 - 0…850 °C (4), T4 - 0…800 °C (4), T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T12 - 50…100 °C, T19 - 0…100 °C, T22 - -200…200 °C
G4
Diameter 'd' [mm]
G6
Probe length 'n' [mm]
10…200 (see tables overleaf)
G7
Probe length 'm' [mm] (1)
30…100 (see tables overleaf)
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1MF…10MF - mineral fiber, 1PV…10PV - PVC
G9
Mounting connection
Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q7 - M12x1.5, Q8 - M14x1.5, Q10 - 1/2" NPT, Q18 - G1/8", Q19 - 1/8" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Q26 - M8x1, Q29 - M8x1.25, Q30 - M10x1.5, Q31 - M6x1, Uxx - union nut (xx - same as for Qxx)
G10
Sheath material (wetted parts)
G11
Accuracy class
RTD
4, 5, 6, 8
T/C
5, 6, 8
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
RTD
X - none (2), A - 'A', B - 'B', C - '2xB'
T/C
1 - '1' (4), 2 - '2'
(3)
2, 3, 4 (4)
G12
Number of wires
G14
Tip shape
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface
RTD
X - standard closed, N - narrowed, P - pitted
T/C
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
(1)
Only for TSAG2 and TSAGL2! For non-Pt sensors Only for RTD sensors! (4) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
SPRING THERMOCOUPLE FOR SURFACE MEASUREMENT
TSAS
Sheath - stainless steel (see table notes) Extension cable - see table notes
SENSITIVE ELEMENT 1 x J, 1xT 1 x K, 1xN
TEMPERATURE RANGE
DIMENSIONS WIRE [mm]
d [mm]
T8
0...400 °C
0.5
10, 12
T4
0...800 °C
0.5
10, 12
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9)
n = 80 … 160 mm
k = 1 ... 10 m
Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) Tip shape: exposed hot junction, flat-surfaced (see Appendix - Tip Shapes) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) Thermocouple connector: 'standard' (C5) or 'miniature' (C6) (see Appendix - Connectors)
TSAS - G2.G3.G4.G6.G8.G10.G11.G15 - #1
Code Feature or option G2
Thermocouple
Code values J - type "J", K - type "K", T - type "T", N - type "N"
G3
Temperature range
T4 - 0…800 °C, T8 - 0…400 °C
G4
Diameter 'd' [mm]
10, 12
G6
Probe length 'n' [mm]
80…160
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
G11
Accuracy class
1 - '1' (1), 2 - '2'
G15
Connector
X - none, C5 - T/C connector, C6 - miniature T/C connector
Options
X - none, OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface
#1 (1)
Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
temperature probes
CABLE PROBE WITH SCREW FIXING FOR SURFACE MEASUREMENT
TSAT
DIMENSIONS SENSITIVE ELEMENT
Sheath - stainless steel (see table notes) Cable - see table notes
CABLE TYPE
TEMPERATURE RANGE
d [mm]
wires
4, 5
2, 3*
6
2, 3, 4*
6
2x2
6
2, 3
4, 5, 6
2
RTD Design 1 x Pt (RB,RD,RF,RG) 2 x Pt (RB,RD,RF,RG) 1 x PTC (RP, RQ)
-50...200 °C -50...100 °C
SLSL, TSL, TT, YY, UU, YU
T9 T12
GLGL
T7 T8
TT
T22 -200...200 °C
SLSL, TSL, YY, UU, YU
T12
-50...100 °C
GLGL, TT
T19
0...100 °C
0...200 °C 0...400 °C
Thermocouple Design T9
-50...200 °C
1 x J,
SLSL, TSL, YY, UU, YU
1xT
GLGL, TT
T8
0...400 °C
1 x K,
n = 20 … 30 mm
k = 1 … 10 m
d
4
5
6
□
6x6
7x7
8x8
D
3
3, 4
3, 4, 5
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Tip shape: - RTD: standard - T/C: standard (isolated) or grounded (see Appendix - Tip Shapes) Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors)
COMECO reserves the right of changing specifications without prior notice!
* Please contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
Ordering code
TSAT - G1G2.G3.G4.G5.G6.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option
Code values
G1
Number of sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RP -PTC 1k, RQ - PTC 2k, J - T/C type "J", K - T/C type "K", T - T/C type "T"
G3
Temperature range
T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T12 - 50…100 °C, T19 - 0…100 °C, T22 - -200…200 °C
G4
Diameter 'd' [mm]
4, 5, 6 (1)
G5
Diameter 'D' [mm]
G6
Probe length 'n' [mm]
20…30
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (5), 1PV…10PV - PVC
G10
Sheath material (wetted parts)
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
G11
Accuracy class
G12
Number of wires (3)
G14
Tip shape (hot junction)
3, 4, 5
RTD
X - none (2), A - 'A', B - 'B', C - '2xB'
T/C
1 - '1' (5), 2 - '2' 2, 3, 4 (5)
(4)
X - standard (isolated from sheath), G - grounded
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface
(1)
Applicable for the selected diameter 'd' For non-Pt sensors Only for RTD sensors! (4) Only for thermocouples! (5) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
CERAMIC PROBE WITH EXTENSION CABLE
TSAZx
DIMENSIONS SENSITIVE ELEMENT
Sheath - ceramic (see table notes) Holding tube - stainless steel 1.4301 or 1.4541 Extension cable - see table notes
TEMPERATURE RANGE T13
DESIGN WITH HOLDING TUBE (TSAZ1)
1 x K,
T16
WIRE [mm] MI [mm]
0...1000 °C
1.0
0...1100 °C
MI 3.0, 4.5 (Inconel 600)
1xN
n [mm]
50...300; 310…600
T6
0...1200 °C
MI 3.0, 4.5 (Nicrobell®)
1xS
T5
0...1500 °C
0.35
100...300;
1xR
T14
0...1600 °C
0.5
310…600
T14
0...1600 °C
0.35
100...300;
T15
0...1700 °C
0.5
310…600
1xB
Ceramic sheath material: Oxal 710 (C2), Alsint 799 (C3), Hexoloy® (C6) (see Appendix - Sheath Materials)
DESIGN WITH HIGH-TEMPERATURE CABLE (TSAZ2)
Cable type: - SLSL or TSL (silicone, max. 250 °C ambient temperature) - GLGLP (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SFSF (mineral fiber, max. 1000 °C ambient temperature) - KFKF (ceramic fiber, max. 1200 °C ambient temperature) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)
k = 1 … 10 mm
Thermocouple connector: 'standard' (C5) or 'miniature' (C6) (see Appendix - Connectors) * Please contact COMECO!
TSAZ(1,2) - G2.G3.G6.G8.G10.G11.G15 - #1
Code Feature or option G2
Code values
Thermocouple
K - type "K", N - type "N", S - type "S", R - type "R", B - type "B"
G3
Temperature range
T5 - 0…1500 °C, T6 - 0…1200 °C, T13 - 0…1000 °C, T14 - 0…1600 °C, T15 - 0…1700 °C, T16 - 0…1100 °C
G6
Probe length 'n' [mm]
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1MF…10MF - mineral fiber, 1CF…10CF - ceramic fiber
G10
Sheath material
C2 - ceramic Oxal 710, C3 - ceramic Alsint 799, C6 - Hexoloy®
G11
Accuracy class
1 - '1' (1), 2 - '2'
G15
Connector
X - none, C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OB - braid termination lead (only w/o connector)
(1)
T/Cs "K", "N'
50…600
T/Cs "S", "R", "B"
100…600
Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
temperature probes (MI**) RTD BAYONET CABLE PROBE
TSBx
Sheath - stainless steel (see table notes) Cable - see table notes STRAIGHT-TUBE DESIGN (TSB)
SENSITIVE ELEMENT 1 x Pt (RB,RD,RF,RG)
2 x Pt (RB,RD,RF,RG) 1 x Cu (RH, RK)
n = 10 … 200 mm k = 1 … 10 m
2 x Cu (RH, RK)
CABLE TYPE
TEMPERATURE RANGE
DIMENSIONS d [mm]
wires
SLSL, TSL, TT YY, UU, YU
T7 T9
0...200 °C -50...200 °C
4, 4.5**, 5
2, 3*
6
2, 3, 4*
SLSL, TSL, TT, GLGL
T1 T8
-50...400 °C 0...400 °C
8
2, 3, 4
GLGL, SFSF TT, TSL, SLSL
T11* -50...600 °C T22 -200...200 °C
6, 8
SLSL, TSL, YY, UU, YU
T9
-50...200 °C
GLGL, TT
T7
0...200 °C
2x2, 2x3*
5*
2, 3*
6
2, 3, 4*
8
2, 3, 4
6, 8
2x2, 2x3*
1 x PTC (RP, RQ)
SLSL, TSL, YY, UU, YU
T12
-50...100 °C
6
2, 3
2 x PTC (RP, RQ)
GLGL, TT
T19
0...100 °C
8
2x2
DESIGN WITH ANGLED TERMINATION (TSBL) Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) - SFSF (mineral fiber, max. 1000 °C ambient temperature) Applicable cables: n = 10 … 200 mm k = 1 … 10 m
STRAIGHT DESIGN WITH MOVABLE CONNECTION (TSBG)
Probe design Temp. range
TSB, TSBG
T12, T19
TSBL, TSBGL
all
all
T7, T9
no PUR, no PVC
T22 T1, T8
GLGLP, SFSF
TT, SLSL, TSL no PUR, no PVC
SFSF
GLGLP, SFSF
TT
T11
Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes)
n = 10 … 200 mm k = 1 … 10 m
Cable connector: 4-pin (C3) (see Appendix - Connectors) Bayonet: ø13x1... ø20x1; aluminum, brass, or stainless steel
ANGLED DESIGN WITH MOVABLE CONNECTION (TSBGL) Available threads and HEX sizes: G SW
M8
M10 1/8"
M12 1/4"
M14
M16 3/8"
M18
M20 1/2"
10
12(13)
14
17
19
22
24
* Please contact COMECO! n = 10 … 200 mm k = 1 … 10 m
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
** Available only for TSBL and TSBGL!
COMECO reserves the right of changing specifications without prior notice!
Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance)
temperature probes
Ordering code
TSB(L,G,GL) - (MI -(1)) G1G2.G3.G4.G5'5".G6.G8.G9.G10.G11.G12.G14.G15 - #1
Code Feature or option
Code values
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP -PTC 1k, RQ - PTC 2k
G3
Temperature range
T1 - -50…400 °C, T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T11 - -50…600 °C (1,2,7), T12 - 50…100 °C, T19 - 0…100 °C, T22 - -200…200 °C
G4
Diameter 'd' [mm]
G5'
Bayonet size (3)
regular design
4, 5, 6, 8
MI design
4.5, 6, 8 (7) 13 - ø13x1, 14 - ø14x1, 15 - ø15x1, 17 - ø17x1, 20 - ø20x1, Z - other (specify!)
(3)
G5"
Bayonet material
G6
Probe length 'n' [mm]
10…200
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (7), 1MF…10MF - mineral fiber, 1PV…10PV - PVC
G9
Mounting connection (4)
Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q7 - M12x1.5, Q8 - M14x1.5, Q10 - 1/2" NPT, Q18 - G1/8", Q19 - 1/8" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Q26 - M8x1, Q29 - M8x1.25, Q30 - M10x1.5, Uxx - union nut (xx - same as for Qxx)
G10
Sheath material (wetted parts)
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
G11
Accuracy class
X - none (5), A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (7)
G14
Tip shape
X - standard closed, N - narrowed (6), P - pitted (6)
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only)
Options
X - none, OV - vibration proof (MgO or Silicone filled) (6), OS - cable protection SS spring (≈ 50 mm) (1), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface (6)
#1
AL - aluminum, BR - brass, SS - stainless steel
(1)
Available only for TSBL and TSBGL! Available only for MI design! Only for TSB and TSBL! (4) Only for TSBG and TSBGL! (5) For non-Pt sensors (6) Only for non-MI (regular) design! (7) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes (MI**) T/C BAYONET CABLE PROBE
TSBx
Sheath - stainless steel (see table notes) Cable - see table notes
SENSITIVE ELEMENT
CABLE TYPE
DIMENSIONS
TEMPERATURE RANGE
d [mm]
wires
Regular Design
STRAIGHT-TUBE DESIGN (TSB) 1xK
1xJ n = 10 … 200 mm k = 1 … 10 m
1xT
SLSL, TSL, TT YY, UU, YU
T7 T9
0...200 °C -50...200 °C
SLSL, TSL, TT, GLGL
T1 T8
-50...400 °C 0...400 °C
GLGL, SFSF
T4 T3*
SLSL, TSL, TT YY, UU, YU
T7 T9
0...200 °C -50...200 °C
SLSL, TSL, TT, GLGL
T1 T8
-50...400 °C 0...400 °C
GLGL, SFSF
T4*
YY, UU, YU SLSL, TSL, TT GLGL
T7 T9
DESIGN WITH ANGLED TERMINATION (TSBL)
1xE
1xT
STRAIGHT DESIGN WITH MOVABLE CONNECTION (TSBG)
2
4, 5, 6, 8
2
4, 5, 6, 8
2
4.5, 6, 8
2
4.5, 6, 8
2
0...800 °C 0...850 °C
0...800 °C 0...200 °C -50...200 °C
MI Design **
1 x N,
n = 10 … 200 mm k = 1 … 10 m
4, 5, 6, 8
SLSL, TSL, TT YY, UU, YU
T7 T9
0...200 °C -50...200 °C
SLSL, TSL, TT, GLGL
T1 T8
-50...400 °C 0...400 °C
GLGL, SFSF
T4 T3*
YY, UU, YU SLSL, TSL, TT GLGL
T7 T9
0...800 °C 0...850 °C 0...200 °C -50...200 °C
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9), 1.4841 (M5), 2.4816 (M8) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) - SFSF (mineral fiber, max. 1000 °C ambient temperature) Applicable cables:
n = 10 … 200 mm k = 1 … 10 m
ANGLED DESIGN WITH MOVABLE CONNECTION (TSBGL)
TSB, TSBG
TSBL, TSBGL
T7, T9
no PUR, no PVC
all
T1, T8
GLGLP, SFSF
no PUR, no PVC
T3, T4
SFSF
GLGLP, SFSF
Tip shape: standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors) Bayonet: ø13x1... ø20x1; aluminum, brass, or stainless steel Available threads and HEX sizes: G SW
n = 10 … 200 mm k = 1 … 10 m
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
M8
M10 1/8"
M12 1/4"
M14
M16 3/8"
M18
M20 1/2"
10
12(13)
14
17
19
22
24
* Please contact COMECO! ** Available only for TSBL and TSBGL!
COMECO reserves the right of changing specifications without prior notice!
Probe design Temp. range
temperature probes
Ordering code
TSB(L,G,GL) - (MI -(1)) G2.G3.G4.G5'5".G6.G8.G9.G10.G11.G14.G15 - #1
Code Feature or option
Code values regular design
J - type "J", K - type "K", T - type "T"
G2
Thermocouple
G3
Temperature range
G4
Diameter 'd' [mm]
G5'
Bayonet size (2)
13 - ø13x1, 14 - ø14x1, 15 - ø15x1, 17 - ø17x1, 20 - ø20x1, Z - other (specify!)
G5"
Bayonet material (2)
AL - aluminum, BR - brass, SS - stainless steel
G6
Probe length 'n' [mm]
10…200
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (5), 1MF…10MF - mineral fiber, 1PV…10PV - PVC
G9
Mounting connection (3)
Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q7 - M12x1.5, Q8 - M14x1.5, Q10 - 1/2" NPT, Q18 - G1/8", Q19 - 1/8" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Q26 - M8x1, Q29 - M8x1.25, Q30 - M10x1.5, Uxx - union nut (xx - same as for Qxx)
G10
Sheath material (wetted parts)
G11
Accuracy class
1 - '1' (5), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled) (4), OS - cable protection SS spring (≈ 50 mm) (1), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface (4)
MI design
E - type "E", N - type "N", T - type "T" T1 - -50…400 °C, T3 - 0…850 °C (5), T4 - 0…800 °C (5), T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C
regular design
4 (5), 5, 6, 8
MI design
4.5, 6, 8 (5)
regular design
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
MI design
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404
(1)
Available only for TSBL and TSBGL! Only for TSB and TSBL! Only for TSBG and TSBGL! (4) Only for non-MI (regular) design! (5) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
BAYONET CABLE INSERT
TSBS
Sheath - stainless steel (see table notes) Cable - see table notes
SENSITIVE ELEMENT
CABLE TYPE
TEMPERATURE RANGE
DIMENSIONS d [mm]
wires
RTD Design
1 x Pt (RB,RD,RF,RG)
SLSL, TSL
T9 T1*
GLGL, TT
T7 T8
-50...200 °C -50...400 °C
5
2, 3*
0...200 °C 0...400 °C
6, 7, 8
2, 3
5*, 6, 7, 8
2
Thermocouple Design SLSL, TSL
T9 T1*
GLGL, TT
T7 T8
1 x K, 1xJ
-50...200 °C -50...400 °C 0...200 °C 0...400 °C
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9)
n = 5 … 25 mm
Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature)
k = 1 … 10 m
insert diameter 'd' [mm]
5
6
7
8
spring OD [mm]
5
6
7
8
Tip shape: - RTD: standard - T/C: standard (isolated) or grounded (see Appendix - Tip Shapes) Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors) Bayonet: - ø14x1; aluminum or Ni-plated brass (default) - ø12x1, ø15x1, ø18x1, or other on request * Please contact COMECO!
TSBS - G2.G3.G4.G5.G6.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option G2
Code values
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, J - T/C type "J", K - T/C type "K"
G3
Temperature range
T7 - 0…200 °C, T9 - -50…200 °C, T8 - 0…400 °C, T1 - -50…400 °C
G4
Diameter 'd' [mm]
5, 6, 7, 8
G5
Bayonet
12 - ø12x1, 14 - ø14x1, 15 - ø15x1, 18 - ø18x1, Z - other (specify!) (3)
G6
Probe length 'n' [mm]
5…25
G8
Cable length 'k' [m] and type
G10
G11
Sheath material (wetted parts) Accuracy class (1)
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®
RTD
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
T/C
M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
RTD
A - 'A', B - 'B', C - '2xB'
T/C
1 - '1' (3), 2 - '2' 2, 3 (3)
G12
Number of wires
G14
Tip shape (hot junction) (2)
X - standard (isolated from sheath), G - grounded
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface
(1) (2) (3)
Only for RTD sensors! Only for thermocouples! Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
temperature probes (MI) RTD PROBE FOR HEAD ASSEMBLY
TSECx
Sheath - stainless steel (see Appendix - Sheath materials) Extension wires - Teflon® or glass fiber
SENSITIVE ELEMENT
DIMENSIONS
TEMPERATURE RANGE
n [mm]
d [mm]
wires
Regular Design
DESIGN WITHOUT EXTENSION (TSEC) 1 x Pt (RB,RD,RF,RG)
2(3) x Pt (RB,RD,RF,RG)
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C
1 x Cu (RH, RK)
T9
-50...200 °C
2 x Cu (RH, RK)
T9
-50...200 °C
T12
-50...100 °C
1 x PTC (RP, RQ)
EXTENDED DESIGN WITH MOVABLE CONNECTION (TSEC2)
DESIGN WITH ADJUSTABLE CONNECTION (TSEC3)
DESIGN WITH GLAND-TYPE CONNECTION (TSEC4)
2 x Pt (RB,RD,RF,RG)
T9 T1 T24 T11 T2 T4 T22
50…1500
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C
2, 3* 2, 3, 4*
50…3000 8, 10, 12, 14, 16, 20
2, 3, 4
6*, 8, 10
2x2(3)*
12, 14, 16, 20
2x2(3), 3x2
50…3000 50…1500
6
2, 3, 4*
50…3000 8, 10, 12, 14, 16, 20 50…3000
50…1500 50…3000 50…3000 MI Design
2 x PTC (RP, RQ)
1 x Pt (RB,RD,RF,RG)
4 5 6
50…500
8, 10 12, 14, 16, 20 6 8, 10, 12, 14 8, 10, 12, 14
2x2 2x2(3)*
3*
2, 3*
2x2
4.5
2, 3*
6
2, 3, 4*
8
2, 3, 4
6, 8
2x2, 2x3*
50...50000
50...50000
2, 3
Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Head connection 'GH': - M10x1(Q20), M12x1.5(Q7), M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2) - 1/4"(Q23/Q24), 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11) - welding Extension length: m = 0…1500 mm (w/o spring-loaded adapter) m = m1...1500 mm (w/ spring-loaded adapter) Extension diameter: (for TSEC1 and TSEC2 only, [mm]) Probe diameter 'd' Ext. length 'm' up to 50 mm 50...150 mm 150...500 mm 500+ mm
3, 4 mm 8 8 10 14
4.5...6 mm d 8 10 14
8 mm d d 10 14
10 mm d d d 14
10+ mm d d d d
Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes) Process pressure: Probe design Max. pressure *
DESIGN WITH NIPPLE-UNION-NIPPLE CONNECTION (TSEC5)
TSEC, TSEC1 25 bar
TSEC4 6 bar
TSEC3, TSEC5 0 bar
Sheath material: 1.4301(M1), 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362(M15) Wire material: Cu, Ni, or Ag Extension wire isolation: Teflon® (T) or glass fiber (GL) Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Spring-loaded adapter: (mounted between probe and protection head)
m1
100...150
GH
20...25
* Please contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
TSEC2 16 bar
m1 = 60…100 mm d ≤ 8 mm
COMECO reserves the right of changing specifications without prior notice!
EXTENDED DESIGN WITH WELDED CONNECTION (TSEC1)
T9 T1 T24 T11 T2 T4 T22
temperature probes
Ordering code
TSEC(1,2,3,4,5) - (MI -) G1G2.G3.G4.G6.G7.G9'9".GH.G10.G11.G12.G13.G14 - #1
Code Feature or option
Code values
G1
Number of RTD sensors
1, 2, or 3 (10)
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP - PTC 1k, RQ - PTC 2k
G3
Temperature range
T1 - -50…400 °C, T2 - -200…600 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C, T22 - -200…200 °C, T24 - -50…500 °C
G4
Diameter 'd' [mm]
G6
Probe length 'n' [mm] (1)
50…50000 (see table overleaf)
G7
Probe length 'm' [mm] (2)
0…1500 (m1…1500 with 'OA' option)
G9'
Mounting connection
X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9"
Compression fitting ferrule (4)
BR - brass, GR - graphite, SS - stainless steel, TF - Teflon®
GH
Head connection
W - welding, Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q6 - G3/4", Q7 - M12x1.5, Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Z - other connection (specify!)
G10
Sheath material (wetted parts)
G11
Accuracy class
X - none (5), A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (10)
(6)
regular design
4, 5, 6, 8, 10, 12, 14, 16, 20
MI design
3 (10), 4.5, 6, 8
regular design MI design
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404), M15 - 1.4362 (10) M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404)
CU - copper (7), NI - nickel, AG - silver (8)
G13
Wire material
G14
Tip shape
X - standard closed, N - narrowed (8), P - pitted (8)
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled) (8), OA - spring-loaded adapter (9), OP - electrochemically polished sheath surface (8)
(1)
'n+m' for TSEC3 and TSEC4! Only for TSEC1, TSEC2, and TSEC5! Only for TSEC! (4) Only for TSEC4! (5) For non-Pt sensors (6) Only for Pt sensors! (7) Not applicable to non-MI (regular) RTDs for above 500 °C! (8) Only for non-MI (regular) design! (9) Only for TSEC, TSEC1, and TSEC5! (10) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes (MI) T/C PROBE FOR HEAD ASSEMBLY
TSECx
Sheath - stainless steel (see Appendix - Sheath materials) Extension wires - Teflon® or glass fiber
SENSITIVE ELEMENT
TEMPERATURE RANGE
1(2) x J 1(2) x L
T4
0...800 °C
1(2) x K
T3 T16 T6*
0...850 °C 0...1100 °C 0...1150 °C
1(2) x E
T3 T13
1(2) x S 1(2) x R
DIMENSIONS n [mm]
d [mm]
wires
50...1500 50...3000
6 8, 10, 12, 14, 16, 20, 22
2 (2x2)
50...1500
6
50...3000
8, 10, 12, 14, 16, 20, 22
0...850 °C 0...1000 °C
50...1500 50...3000
6 8, 10, 12, 14, 16, 20, 22
2 (2x2)
T16 T6*
0...1100 °C 0...1150 °C
50...1500
6
50...3000
8, 10, 12, 14, 16, 20, 22
2 (2x2)
T4
0...800 °C
50...50000
3, 4.5, 6, 8, 10*
T8
0...400 °C
50...50000
3, 4.5, 6, 8, 10*
0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C
50...50000
3, 4.5, 6, 8, 10*
2
2xK 2 x N, 2 x E
T3 T16 T6* T6*
50...50000
3, 4.5, 6, 8, 10*
2x2
2xS 2xR
T16 T6*
0...1100 °C 0...1150 °C
50...10000
3, 4.5, 6
2x2
Regular Design
EXTENDED DESIGN WITH WELDED CONNECTION (TSEC1)
MI Design 1xJ 2xJ 1xT 2xT 1xK 1 x N, 1 x E
EXTENDED DESIGN WITH MOVABLE CONNECTION (TSEC2)
DESIGN WITH ADJUSTABLE CONNECTION (TSEC3)
DESIGN WITH GLAND-TYPE CONNECTION (TSEC4)
2 (2x2)
2 2x2 2 2x2
Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Head connection 'GH': - M10x1(Q20), M12x1.5(Q7), M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2) - 1/4"(Q23/Q24), 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11) - welding Extension length: m = 0…1500 mm (w/o spring-loaded adapter) m = m1...1500 mm (w/ spring-loaded adapter) Extension diameter: (for TSEC1 and TSEC2 only, [mm]) Probe diameter 'd' Ext. length 'm' up to 50 mm 50...150 mm 150...500 mm 500+ mm
3 mm
4.5, 6 mm
8 mm
10 mm
10+ mm
6 8 10 14
d 8 10 14
d d 10 14
d d d 14
d d d d
Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Process pressure: Probe design Max. pressure *
DESIGN WITH NIPPLE-UNION-NIPPLE CONNECTION (TSEC5)
TSEC, TSEC1 25 bar
TSEC4 6 bar
TSEC3, TSEC5 0 bar
Sheath material: 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362 (M15) MI sheath material: 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4876(M7), 2.4816(M8), Nicrobell® (M10) Extension wire isolation: Teflon® (T) or glass fiber (GL) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) Spring-loaded adapter: (mounted between probe and protection head)
m1
100...150
GH
20...25
* Please contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
TSEC2 16 bar
m1 = 60…100 mm d ≤ 8 mm
COMECO reserves the right of changing specifications without prior notice!
DESIGN WITHOUT EXTENSION (TSEC)
temperature probes
Ordering code
TSEC(1,2,3,4,5) - (MI -) G1G2.G3.G4.G6.G7.G9'9".GH.G10.G11.G14 - #1
Code Feature or option G1
Number of thermocouples
G2
Thermocouple
G3
Temperature range
G4
Diameter 'd' [mm]
Code values 1 or 2 regular design
E - type "E", J - type "J", K - type "K", L - type "L", R - type "R", S - type "S"
MI design
E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T" T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (7), T13 - 0…1000 °C, T16 - 0…1100 °C
regular design
6, 8, 10, 12, 14, 16, 20, 22
MI design
3, 4.5, 6, 8, 10
(1)
G6
Probe length 'n' [mm]
G7
Probe length 'm' [mm] (2)
0…1500 (m1…1500 with 'OA' option)
50…50000 (see table overleaf)
G9'
Mounting connection
X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9"
Compression fitting ferrule (4)
BR - brass, GR - graphite, SS - stainless steel, TF - Teflon®
GH
Head connection
W - welding, Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q6 - G3/4", Q7 - M12x1.5, Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Z - other connection (specify!)
G10
Sheath material (wetted parts)
regular design
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762, M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4401 (1.4404), M15 - 1.4362
MI design
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4401 (1.4404), M10 - Nicrobell®
G11
Accuracy class
1 - '1' (7), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
#1
Options
X - none, OA - spring-loaded adapter (5), OP - electrochemically polished sheath surface (6)
(1)
'n+m' for TSEC3 and TSEC4! Only for TSEC1, TSEC2, and TSEC5! Only for TSEC! (4) Only for TSEC4! (5) Only for TSEC, TSEC1, and TSEC5! (6) Only for non-MI (regular) design! (7) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
ANGLED PROBE WITH SCREW FIXING
TSG
Sheath - stainless steel (see table notes) Cable - see table notes
SENSITIVE ELEMENT 1 x Pt (RB,RD,RF,RG) 1 x K, 1 x J, 1xT
n = 10 ... 30 mm k = 1 ... 10 m
CABLE TYPE GLGL
TEMPERATURE RANGE T8 T7
0...400 °C 0...200 °C
SLSL, TSL
T9
-50...200 °C
TT
T7
YY, UU, YU
T10 T12
DIMENSIONS d [mm]
wires
4*, 5
2, 3*
6
2, 3
5, 6
2
0...200 °C -10...60 °C -50...100 °C
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Tip shape: - RTD: standard - T/C: standard (isolated) or grounded (see Appendix - Tip Shapes)
□
8x8
10x10
Lmin
7
9
d
4, 5
4, 5, 6
Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors) * Please contact COMECO!
TSG - G2.G3.G4.G5.G6.G7.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option G2
Code values
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, J - T/C type "J", K - T/C type "K", T - T/C type "T"
G3
Temperature range
T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T10 - -10…60 °C, T12 - -50…100 °C
G4
Diameter 'd' [mm]
4, 5, 6
G5
Dimension '□'
8 - 8x8 mm, 10 - 10x10 mm
G6
Probe length 'n' [mm]
10…30
G7
Dimension 'L' [mm]
7…20
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (3), 1PV…10PV - PVC
G10
Sheath material
G11 G12 G14
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
Accuracy class Number of wires
(1)
Tip shape (hot junction)
RTD
A - 'A', B - 'B', C - '2xB'
T/C
1 - '1' (3), 2 - '2' 2, 3
(2)
X - standard (isolated from sheath), G - grounded
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface
(1)
Only for RTD sensors! Only for thermocouples! (3) Contact COMECO! (2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
temperature probes
PENETRATION RTD PROBE WITH HANDLE
TSIx
SENSITIVE ELEMENT
Sheath - stainless steel (see table notes) Cable and handle - see table notes DESIGN WITH SILICONE HANDLE (TSI1)
TEMPERATURE RANGE
1 x Pt (RB,RD,RF,RG)
T9
2 x Pt (RB,RD,RF,RG)
k = 1 … 10 m
T9
DIMENSIONS d [mm]
-50...200 °C
-50...200 °C
wires
4, 5
2, 3*
6
2, 3, 4*
8
2, 3, 4
5, 6
2x2
8
2, 3*
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Cable type: - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature)
DESIGN WITH PLASTIC HANDLE (TSI2)
Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Handle type: - silicone (TSI1) - glass-filed plastic (TSI2) - stainless steel 1.4301 (TSI3)
k = 1 … 10 m
DESIGN WITH ROBUST METAL HANDLE (TSI3)
Filling: thermal conductive paste Cable connector: 4-pin (C3) (see Appendix - Connectors) Dimension limits: Model d=4
TSI1, TSI2 n = 50...200
TSI3 n = 50...200
d=5
n = 50...300
n = 50...300
d=6
n = 50...500
n = 50...500
d=8
-
n = 50...800
k = 1 … 10 m * Please contact COMECO!
Ordering code
TSI(1,2,3) - G1G2.G4.G6.G8.G10.G11.G12.G15 - #1 Code values
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000
G4
Diameter 'd' [mm]
4, 5, 6, 8
G6
Probe length 'n' [mm]
50…500
G8
Cable length 'k' [m] and type
1SL…10SL - silicone, 1TF…10TF - Teflon® (1)
G10
Sheath material (wetted parts)
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
(1)
G11
Accuracy class
G12
Number of wires
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only)
#1
Options
X - none, OP - electrochemically polished sheath surface
(1)
A - 'A', B - 'B', C - '2xB' 2, 3 (1), 4 (1)
Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Code Feature or option
temperature probes
(MI) HAND-HELD PROBE WITH CONNECTOR
TSHx
DIMENSIONS SENSITIVE ELEMENT
Sheath - see table Cable - see table notes Connector - see table notes
SHEATH MATERIAL
TEMPERATURE RANGE
d [mm]
wires
RTD Design
DESIGN WITH PLASTIC HANDLE (TSH)
1 x Pt (RB,RD,RF,RG)
M1, M2, M3, M9
1 x Cu (RH, RK)
T7 T8 T1* T7
0...200 °C 0...400 °C -50...400 °C
4, 5
2, 3*
6
2, 3, 4*
0...200 °C
5*, 6
2, 3, 4*
5, 6
2
1, 1.5, 2, 3, 4.5, 6, 8, 10
2
1, 1.5, 2, 3, 4.5, 6, 8
2
Regular Thermocouple Design 1 x K, 1 x J,
M2, M3, M9
1xT n = 200 ... 2 000 mm
d ≤ 6 mm
T7
0...200 °C
T8
0...400 °C
MI Thermocouple Design
k = 1 … 10 m
M2, M3, M8 1 x J, 1 x T **
M9, M5
T4
0...800 °C
M4
DESIGN WITH ROBUST METAL HANDLE (TSHN)
M2, M3 T3
0...850 °C
M9 1 x K, 1 x N, n = 200 ... 2 000 mm
k = 1 … 10 m
6, 8
2
3, 4.5, 6
2
1, 1.5, 2, 3, 4.5, 6, 8, 10
2
1, 1.5, 2, 3, 4.5, 6, 8
2
M10
1 x E **
M7*
3, 6, 10
2
T16
0...1100 °C
1, 1.5, 2, 3, 4.5, 6, 8, 10
2
6, 8
2
T6
0...1150 °C
1.5, 3, 4.5, 6, 8
2
M10
T6
0...1250 °C
3, 4.5, 6
2
M8
T16
0...1100 °C
3, 4.5, 6
2
M8 M4 M5
1 x S(R)
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4762 (M4), 1.4841 (M5), 1.4876 (M7), 2.4816 (M8), 1.4404 (M9), Nicrobell® (M10)
Tip shape: - RTD: standard, narrowed, pitted - T/C: standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors) * Please contact COMECO! ** For T/C type "T": (T8) 0...400 °C; for T/C type "E": (T13) 0...1000 °C
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature)
temperature probes
Ordering code
TSH(N) - (MI-) G2.G3.G4.G6.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option G2
G3
G4
Code values regular design
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, J - T/C type "J", K - T/C type "K", T - T/C type "T"
MI design
E - T/C type "E", J - T/C type "J", K - T/C type "K", N - T/C type "N", R - T/C type "R", S - T/C type "S", T - T/C type "T"
Sensor
T1 - -50…400 °C, T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1150(1250) °C, T7 - 0…200 °C, T8 - 0…400 °C, T16 - 0…1100 °C
Temperature range
Diameter 'd' [mm]
RTD
4, 5, 6, 8
regular T/C design
5, 6
MI T/C design
1, 1.5, 2, 3, 4.5, 6, 8, 10
G6
Probe length 'n' [mm]
G8
Cable length 'k' [m] and type
G10
G11
Sheath material (wetted parts)
Accuracy class
200…2000 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®
RTD
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
regular T/C design
M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
MI T/C design
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®
RTD
X - none (1), A - 'A', B - 'B', C - '2xB'
T/C
1 - '1' (5), 2 - '2'
(2)
2, 3, 4 (5)
G12
Number of wires
G14
Tip shape
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled) (4), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface (4)
RTD
X - standard closed, N - narrowed, P - pitted
T/C
X - standard (isolated from sheath) (3), G - grounded, E - exposed hot junction (3), O - open-tube design (3)
(1)
For non-Pt sensors Only for RTD sensors! (3) Not available when d = 1! (4) Only for non-MI (regular) design! (5) Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
MAGNETIC PROBE FOR SURFACE MEASUREMENT
TSM
Design - pawn-type plastic body w/ permanent magnet ring Cable - see table notes
SENSITIVE ELEMENT 1 x Pt (RB,RD,RF,RG) 1 x K, 1xJ
CABLE TYPE
TEMPERATURE RANGE
WIRES
SLFSL, TFT
T7** T9**
0...200 °C -50...200 °C
2, 3*
YFY
T10 T12 T19
-10...60 °C -50...100 °C 0...100 °C
2
1xT
2
Sheath material: PPS plastic, magnet ring w/ ferrous metal jacket Cable type: - SLFSL or TFSL (silicone w/ copper shield, max. 250 °C ambient temperature) - TFT (Teflon® w/ copper shield, max. 250 °C ambient temperature) - YFY (PVC w/ copper shield, max. 105 °C ambient temperature) k = 1 ... 10 m Tip shape: - RTD: standard - T/C: grounded (see Appendix - Tip Shapes) Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors) * Please contact COMECO! ** Up to 250 °C (short-term)
TSM - G2.G3.G8.G11.G12.G15 - #1
Code Feature or option
Code values
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, J - T/C type "J", K - T/C type "K", T - T/C type "T"
G3
Temperature range
T7 - 0…200(250) °C, T9 - -50…200(250) °C, T10 - -10…60 °C, T12 - -50…100 °C, T19 - 0…100 °C
G8
Cable length 'k' [m] and type
G11
Accuracy class (1)
1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PV…10PV - PVC
RTD
A - 'A', B - 'B', C - '2xB'
T/C
1 - '1' (2), 2 - '2' 2, 3 (2)
G12
Number of wires
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OB - braid termination lead (only w/o connector)
(1) (2)
Only for RTD sensors! Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
temperature probes
MAGNETIC THERMOCOUPLE PROBE FOR SURFACE MEASUREMENT
TSMS
Design - SS body w/ chromium plated magnet holder and T/C spring Extension cable - see table notes
SENSITIVE ELEMENT
CABLE TYPE
TEMPERATURE RANGE
WIRE [mm]
1 x K, 1 x J,
GLGLP, GLGLV
T8*
0...350 °C
0.5
1xN Sheath material: magnet holder: Cr-plated black steel sensor body: stainless steel w/ ceramic isolator
k = 1 ... 10 m
Cable type: GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) Tip shape: exposed hot junction, flat-surfaced (see Appendix - Tip Shapes) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) Thermocouple connector: 'standard' (C5) or 'miniature' (C6) (see Appendix - Connectors)
* up to 400 °C for short-term use
Ordering code
TSMS - G2.G8.G11.G15 - #1
Code Feature or option G2
Thermocouple
Code values J - type "J", K - type "K", N - type "N"
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber
G11
Accuracy class
1 - '1' (1), 2 - '2'
G15
Connector
X - none, C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector)
Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(1)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
MINERAL-INSULATED RTD PROBE
TSNx
Sheath - see table Extension cable - see table notes
MI CABLE PROBE ONLY (TSN)
SENSITIVE ELEMENT
SHEATH TEMPERATURE MATERIAL RANGE **
1 x Pt (RB,RD,RF,RG)
M1, M2, M3, M5, M8, M9
2 x Pt (RB,RD,RF,RG)
M1, M2, M3, M5, M8, M9
d
n
T7 T8 T9 T22 T1 T11 T4
0...200 °C 0...400 °C -50...200 °C -200...200 °C -50...400 °C -50...600 °C 0...800 °C
DIMENSIONS d [mm]
wires
3*, 4.5, 6, 8
2, 3, 4*
4.5*, 6, 8
2x2 2x3*
n = 50 ... 50 000 mm Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4841 (M5), 2.4816 (M8), 1.4404 (M9)
DESIGN WITH EXTENSION CABLE (TSNA)
Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature ***) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature ***) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Tip shape: standard or narrowed * (see Appendix - Tip Shapes)
n = 50 ... 50 000 mm k = 1 … 10 m
d D
3 6
4.5 6
6 8
8 d
Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Cable connector: 4-pin (C3) (see Appendix - Connectors)
DESIGN WITH CONNECTOR (TSNH)
Temperature limitation: The temperature around TSNA holding tube and TSNH(A) connector must not exceed -50...200 °C!
n = 50 ... 50 000 mm
DESIGN WITH CONNECTOR AND EXTENSION CABLE (TSNHA)
n
k
~ 60
d
* Please contact COMECO! n = 50 ... 50 000 mm
d ≤ 6 mm
k = 1 … 10 m
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
** Max. 550 °C (for chip RTD) or 800 °C (for wire-wound RTD) *** Sub-zero temperatures are not recommended
COMECO reserves the right of changing specifications without prior notice!
d ≤ 6 mm
temperature probes
Ordering code
TSN(A,H,HA) - G1G2.G3.G4.G6.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option
Code values
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000
G3
Temperature range
T7 - 0…200 °C, T9 - -50…200 °C, T22 - 200…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T11 - 50…600 °C (4), T4 - 0…800 °C (4)
G4
Diameter 'd' [mm] (1)
3 (4), 4.5, 6, 8
G6
Probe length 'n' [mm]
50…50000
G8
Cable length 'k' [m] and type
X - no cable, 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1PV…10PV - PVC
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404
G11
Accuracy class
A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (4)
G14
Tip shape
X - standard (isolated from sheath), N - narrowed (2,4)
G15
Connector
#1
Options
(3)
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only) X - none, OS - cable protection SS spring (≈ 50 mm) (3), OB - braid termination lead (only w/o connector) (3)
(1)
Up to 6 mm for TSNH and TSNHA Only for TSN! Only for TSNA and TSNHA! (4) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
MINERAL-INSULATED THERMOCOUPLE PROBE
TSNx SENSITIVE ELEMENT
Sheath - see table Extension cable - see table notes
SHEATH MATERIAL M1
1 x J,
MI CABLE PROBE ONLY (TSN)
1 x T **
TEMPERATURE RANGE max. 400 °C
M2,M3,M9,M5,M8 M4
d [mm] 1, 1.5, 2, 3, 4.5, 6, 8, 10*
max. 800 °C
6, 8
M10 2xJ 2 x T **
n = 50 ... 50 000 mm 1 x K, 1 x N, 1 x E **
DESIGN WITH EXTENSION CABLE (TSNA)
M1 M2,M3,M9,M5,M8 M4 M2, M3, M9
max. 850 °C
M8 M4
2xK
M7*
2xN
M8 M4 M5
n = 50 ... 50 000 mm k = 1 … 10 m
d D
<6 6
6 8
8, 10 d
DESIGN WITH CONNECTOR (TSNH)
6, 8 1, 1.5, 2, 3, 4.5, 6, 8, 10*
M7*
M2, M3, M9
2 x S(R)
1.5, 2, 3, 4.5, 6, 8, 10*
max. 800 °C max. 400 °C
M10
1 x S(R),
max. 400 °C
M1
M5
2 x E **
3, 4.5, 6
M8
3, 6, 10* max. 1100 °C
max. 1150 °C
1, 1.5, 2, 3, 4.5, 6, 8, 10* 6, 8 1.5, 3, 4.5, 6, 8
max. 1250 °C
3, 4.5, 6
max. 850 °C
1.5, 3, 4.5, 6, 8
max. 1100 °C max. 1150 °C
3, 6, 10* 1.5, 3, 4.5, 6, 8 6, 8 1.5, 3, 4.5, 6, 8
max. 1100 °C
3, 4.5, 6
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4762 (M4), 1.4841 (M5), 1.4876 (M7), 2.4816 (M8), 1.4404 (M9), Nicrobell® (M10) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes)
n = 50 ... 50 000 mm
DESIGN WITH CONNECTOR AND EXTENSION CABLE (TSNHA)
Thermocouple connector: 'standard' (C5) or 'miniature' (C6) (see Appendix - Connectors) Temperature limitation: The temperature around TSNA holding tube and TSNH(A) connector must not exceed -50...200 °C!
n = 50 ... 50 000 mm
d ≤ 6 mm
k = 1 … 10 m
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
* Please contact COMECO! ** For T/C type "T": max. 400 °C; for T/C type "E": max. 1000 °C
COMECO reserves the right of changing specifications without prior notice!
Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)
d ≤ 6 mm
temperature probes
Ordering code
TSN(A,H,HA) - G1G2.G3.G4.G6.G8.G10.G11.G14.G15 - #1
Code Feature or option
Code values
G1
Number of thermocouples
1 or 2 (1)
G2
Thermocouple
E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T"
G3
Temperature range
T7 - 0…200 °C, T9 - -50…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T4 - 0…800 °C, T3 - 0…850 °C, T16 - 0…1100 °C, T6 - 0…1150(1250) °C
G4
Diameter 'd' [mm] (2)
1 (3), 1.5 (4), 2, 3, 4.5, 6, 8, 10
G6
Probe length 'n' [mm]
50…50000
G8
Cable length 'k' [m] and type
X - no cable, 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®
G11
Accuracy class
1 - '1' (6), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
G15
Connector (5)
X - none, C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OS - cable protection SS spring (≈ 50 mm) (5), OB - braid termination lead (only w/o connector) (5)
(1)
Only for TSN. Ask for TSNA! Up to 6 mm for TSNH and TSNHA Always grounded (4) Grounded when G1="2" (5) Only for TSNA and TSNHA! (6) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
MINERAL-INSULATED RTD PROBE
TSNx
Sheath - see table Extension cable - see table notes
MI CABLE PROBE ONLY (TSN)
SENSITIVE ELEMENT
SHEATH TEMPERATURE MATERIAL RANGE **
1 x Pt (RB,RD,RF,RG)
M1, M2, M3, M5, M8, M9
2 x Pt (RB,RD,RF,RG)
M1, M2, M3, M5, M8, M9
d
n
T7 T8 T9 T22 T1 T11 T4
0...200 °C 0...400 °C -50...200 °C -200...200 °C -50...400 °C -50...600 °C 0...800 °C
DIMENSIONS d [mm]
wires
3*, 4.5, 6, 8
2, 3, 4*
4.5*, 6, 8
2x2 2x3*
n = 50 ... 50 000 mm Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4841 (M5), 2.4816 (M8), 1.4404 (M9)
DESIGN WITH EXTENSION CABLE (TSNA)
Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature ***) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature ***) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Tip shape: standard or narrowed * (see Appendix - Tip Shapes)
n = 50 ... 50 000 mm k = 1 … 10 m
d D
3 6
4.5 6
6 8
8 d
Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Cable connector: 4-pin (C3) (see Appendix - Connectors)
DESIGN WITH CONNECTOR (TSNH)
Temperature limitation: The temperature around TSNA holding tube and TSNH(A) connector must not exceed -50...200 °C!
n = 50 ... 50 000 mm
DESIGN WITH CONNECTOR AND EXTENSION CABLE (TSNHA)
n
k
~ 60
d
* Please contact COMECO! n = 50 ... 50 000 mm
d ≤ 6 mm
k = 1 … 10 m
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
** Max. 550 °C (for chip RTD) or 800 °C (for wire-wound RTD) *** Sub-zero temperatures are not recommended
COMECO reserves the right of changing specifications without prior notice!
d ≤ 6 mm
temperature probes
Ordering code
TSN(A,H,HA) - G1G2.G3.G4.G6.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option
Code values
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000
G3
Temperature range
T7 - 0…200 °C, T9 - -50…200 °C, T22 - 200…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T11 - 50…600 °C (4), T4 - 0…800 °C (4)
G4
Diameter 'd' [mm] (1)
3 (4), 4.5, 6, 8
G6
Probe length 'n' [mm]
50…50000
G8
Cable length 'k' [m] and type
X - no cable, 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1PV…10PV - PVC
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404
G11
Accuracy class
A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (4)
G14
Tip shape
X - standard (isolated from sheath), N - narrowed (2,4)
G15
Connector
#1
Options
(3)
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only) X - none, OS - cable protection SS spring (≈ 50 mm) (3), OB - braid termination lead (only w/o connector) (3)
(1)
Up to 6 mm for TSNH and TSNHA Only for TSN! Only for TSNA and TSNHA! (4) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
MINERAL-INSULATED THERMOCOUPLE PROBE
TSNx SENSITIVE ELEMENT
Sheath - see table Extension cable - see table notes
SHEATH MATERIAL M1
1 x J,
MI CABLE PROBE ONLY (TSN)
1 x T **
TEMPERATURE RANGE max. 400 °C
M2,M3,M9,M5,M8 M4
d [mm] 1, 1.5, 2, 3, 4.5, 6, 8, 10*
max. 800 °C
6, 8
M10 2xJ 2 x T **
n = 50 ... 50 000 mm 1 x K, 1 x N, 1 x E **
DESIGN WITH EXTENSION CABLE (TSNA)
M1 M2,M3,M9,M5,M8 M4 M2, M3, M9
max. 850 °C
M8 M4
2xK
M7*
2xN
M8 M4 M5
n = 50 ... 50 000 mm k = 1 … 10 m
d D
<6 6
6 8
8, 10 d
DESIGN WITH CONNECTOR (TSNH)
6, 8 1, 1.5, 2, 3, 4.5, 6, 8, 10*
M7*
M2, M3, M9
2 x S(R)
1.5, 2, 3, 4.5, 6, 8, 10*
max. 800 °C max. 400 °C
M10
1 x S(R),
max. 400 °C
M1
M5
2 x E **
3, 4.5, 6
M8
3, 6, 10* max. 1100 °C
max. 1150 °C
1, 1.5, 2, 3, 4.5, 6, 8, 10* 6, 8 1.5, 3, 4.5, 6, 8
max. 1250 °C
3, 4.5, 6
max. 850 °C
1.5, 3, 4.5, 6, 8
max. 1100 °C max. 1150 °C
3, 6, 10* 1.5, 3, 4.5, 6, 8 6, 8 1.5, 3, 4.5, 6, 8
max. 1100 °C
3, 4.5, 6
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4762 (M4), 1.4841 (M5), 1.4876 (M7), 2.4816 (M8), 1.4404 (M9), Nicrobell® (M10) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes)
n = 50 ... 50 000 mm
DESIGN WITH CONNECTOR AND EXTENSION CABLE (TSNHA)
Thermocouple connector: 'standard' (C5) or 'miniature' (C6) (see Appendix - Connectors) Temperature limitation: The temperature around TSNA holding tube and TSNH(A) connector must not exceed -50...200 °C!
n = 50 ... 50 000 mm
d ≤ 6 mm
k = 1 … 10 m
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
* Please contact COMECO! ** For T/C type "T": max. 400 °C; for T/C type "E": max. 1000 °C
COMECO reserves the right of changing specifications without prior notice!
Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)
d ≤ 6 mm
temperature probes
Ordering code
TSN(A,H,HA) - G1G2.G3.G4.G6.G8.G10.G11.G14.G15 - #1
Code Feature or option
Code values
G1
Number of thermocouples
1 or 2 (1)
G2
Thermocouple
E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T"
G3
Temperature range
T7 - 0…200 °C, T9 - -50…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T4 - 0…800 °C, T3 - 0…850 °C, T16 - 0…1100 °C, T6 - 0…1150(1250) °C
G4
Diameter 'd' [mm] (2)
1 (3), 1.5 (4), 2, 3, 4.5, 6, 8, 10
G6
Probe length 'n' [mm]
50…50000
G8
Cable length 'k' [m] and type
X - no cable, 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®
G11
Accuracy class
1 - '1' (6), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
G15
Connector (5)
X - none, C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OS - cable protection SS spring (≈ 50 mm) (5), OB - braid termination lead (only w/o connector) (5)
(1)
Only for TSN. Ask for TSNA! Up to 6 mm for TSNH and TSNHA Always grounded (4) Grounded when G1="2" (5) Only for TSNA and TSNHA! (6) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
MINERAL-INSULATED RTD PROBE
TSNx
Sheath - see table Extension cable - see table notes
MI CABLE PROBE ONLY (TSN)
SENSITIVE ELEMENT
SHEATH TEMPERATURE MATERIAL RANGE **
1 x Pt (RB,RD,RF,RG)
M1, M2, M3, M5, M8, M9
2 x Pt (RB,RD,RF,RG)
M1, M2, M3, M5, M8, M9
d
n
T7 T8 T9 T22 T1 T11 T4
0...200 °C 0...400 °C -50...200 °C -200...200 °C -50...400 °C -50...600 °C 0...800 °C
DIMENSIONS d [mm]
wires
3*, 4.5, 6, 8
2, 3, 4*
4.5*, 6, 8
2x2 2x3*
n = 50 ... 50 000 mm Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4841 (M5), 2.4816 (M8), 1.4404 (M9)
DESIGN WITH EXTENSION CABLE (TSNA)
Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature ***) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature ***) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Tip shape: standard or narrowed * (see Appendix - Tip Shapes)
n = 50 ... 50 000 mm k = 1 … 10 m
d D
3 6
4.5 6
6 8
8 d
Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Cable connector: 4-pin (C3) (see Appendix - Connectors)
DESIGN WITH CONNECTOR (TSNH)
Temperature limitation: The temperature around TSNA holding tube and TSNH(A) connector must not exceed -50...200 °C!
n = 50 ... 50 000 mm
DESIGN WITH CONNECTOR AND EXTENSION CABLE (TSNHA)
n
k
~ 60
d
* Please contact COMECO! n = 50 ... 50 000 mm
d ≤ 6 mm
k = 1 … 10 m
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
** Max. 550 °C (for chip RTD) or 800 °C (for wire-wound RTD) *** Sub-zero temperatures are not recommended
COMECO reserves the right of changing specifications without prior notice!
d ≤ 6 mm
temperature probes
Ordering code
TSN(A,H,HA) - G1G2.G3.G4.G6.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option
Code values
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000
G3
Temperature range
T7 - 0…200 °C, T9 - -50…200 °C, T22 - 200…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T11 - 50…600 °C (4), T4 - 0…800 °C (4)
G4
Diameter 'd' [mm] (1)
3 (4), 4.5, 6, 8
G6
Probe length 'n' [mm]
50…50000
G8
Cable length 'k' [m] and type
X - no cable, 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1PV…10PV - PVC
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404
G11
Accuracy class
A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (4)
G14
Tip shape
X - standard (isolated from sheath), N - narrowed (2,4)
G15
Connector
#1
Options
(3)
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only) X - none, OS - cable protection SS spring (≈ 50 mm) (3), OB - braid termination lead (only w/o connector) (3)
(1)
Up to 6 mm for TSNH and TSNHA Only for TSN! Only for TSNA and TSNHA! (4) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
MINERAL-INSULATED THERMOCOUPLE PROBE
TSNx SENSITIVE ELEMENT
Sheath - see table Extension cable - see table notes
SHEATH MATERIAL M1
1 x J,
MI CABLE PROBE ONLY (TSN)
1 x T **
TEMPERATURE RANGE max. 400 °C
M2,M3,M9,M5,M8 M4
d [mm] 1, 1.5, 2, 3, 4.5, 6, 8, 10*
max. 800 °C
6, 8
M10 2xJ 2 x T **
n = 50 ... 50 000 mm 1 x K, 1 x N, 1 x E **
DESIGN WITH EXTENSION CABLE (TSNA)
M1 M2,M3,M9,M5,M8 M4 M2, M3, M9
max. 850 °C
M8 M4
2xK
M7*
2xN
M8 M4 M5
n = 50 ... 50 000 mm k = 1 … 10 m
d D
<6 6
6 8
8, 10 d
DESIGN WITH CONNECTOR (TSNH)
6, 8 1, 1.5, 2, 3, 4.5, 6, 8, 10*
M7*
M2, M3, M9
2 x S(R)
1.5, 2, 3, 4.5, 6, 8, 10*
max. 800 °C max. 400 °C
M10
1 x S(R),
max. 400 °C
M1
M5
2 x E **
3, 4.5, 6
M8
3, 6, 10* max. 1100 °C
max. 1150 °C
1, 1.5, 2, 3, 4.5, 6, 8, 10* 6, 8 1.5, 3, 4.5, 6, 8
max. 1250 °C
3, 4.5, 6
max. 850 °C
1.5, 3, 4.5, 6, 8
max. 1100 °C max. 1150 °C
3, 6, 10* 1.5, 3, 4.5, 6, 8 6, 8 1.5, 3, 4.5, 6, 8
max. 1100 °C
3, 4.5, 6
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4762 (M4), 1.4841 (M5), 1.4876 (M7), 2.4816 (M8), 1.4404 (M9), Nicrobell® (M10) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes)
n = 50 ... 50 000 mm
DESIGN WITH CONNECTOR AND EXTENSION CABLE (TSNHA)
Thermocouple connector: 'standard' (C5) or 'miniature' (C6) (see Appendix - Connectors) Temperature limitation: The temperature around TSNA holding tube and TSNH(A) connector must not exceed -50...200 °C!
n = 50 ... 50 000 mm
d ≤ 6 mm
k = 1 … 10 m
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
* Please contact COMECO! ** For T/C type "T": max. 400 °C; for T/C type "E": max. 1000 °C
COMECO reserves the right of changing specifications without prior notice!
Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)
d ≤ 6 mm
temperature probes
Ordering code
TSN(A,H,HA) - G1G2.G3.G4.G6.G8.G10.G11.G14.G15 - #1
Code Feature or option
Code values
G1
Number of thermocouples
1 or 2 (1)
G2
Thermocouple
E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T"
G3
Temperature range
T7 - 0…200 °C, T9 - -50…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T4 - 0…800 °C, T3 - 0…850 °C, T16 - 0…1100 °C, T6 - 0…1150(1250) °C
G4
Diameter 'd' [mm] (2)
1 (3), 1.5 (4), 2, 3, 4.5, 6, 8, 10
G6
Probe length 'n' [mm]
50…50000
G8
Cable length 'k' [m] and type
X - no cable, 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®
G11
Accuracy class
1 - '1' (6), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
G15
Connector
(5)
#1
Options
X - none, C5 - T/C connector, C6 - miniature T/C connector X - none, OS - cable protection SS spring (≈ 50 mm) (5), OB - braid termination lead (only w/o connector) (5)
(1)
Only for TSN. Ask for TSNA! Up to 6 mm for TSNH and TSNHA (3) Always grounded (4) Grounded when G1="2" (5) Only for TSNA and TSNHA! (6) Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
MINERAL-INSULATED RTD PROBE
TSNx
Sheath - see table Extension cable - see table notes
MI CABLE PROBE ONLY (TSN)
SENSITIVE ELEMENT
SHEATH TEMPERATURE MATERIAL RANGE **
1 x Pt (RB,RD,RF,RG)
M1, M2, M3, M5, M8, M9
2 x Pt (RB,RD,RF,RG)
M1, M2, M3, M5, M8, M9
d
n
T7 T8 T9 T22 T1 T11 T4
0...200 °C 0...400 °C -50...200 °C -200...200 °C -50...400 °C -50...600 °C 0...800 °C
DIMENSIONS d [mm]
wires
3*, 4.5, 6, 8
2, 3, 4*
4.5*, 6, 8
2x2 2x3*
n = 50 ... 50 000 mm Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4841 (M5), 2.4816 (M8), 1.4404 (M9)
DESIGN WITH EXTENSION CABLE (TSNA)
Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature ***) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature ***) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Tip shape: standard or narrowed * (see Appendix - Tip Shapes)
n = 50 ... 50 000 mm k = 1 … 10 m
d D
3 6
4.5 6
6 8
8 d
Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Cable connector: 4-pin (C3) (see Appendix - Connectors)
DESIGN WITH CONNECTOR (TSNH)
Temperature limitation: The temperature around TSNA holding tube and TSNH(A) connector must not exceed -50...200 °C!
n = 50 ... 50 000 mm
DESIGN WITH CONNECTOR AND EXTENSION CABLE (TSNHA)
n
k
~ 60
d
* Please contact COMECO! n = 50 ... 50 000 mm
d ≤ 6 mm
k = 1 … 10 m
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
** Max. 550 °C (for chip RTD) or 800 °C (for wire-wound RTD) *** Sub-zero temperatures are not recommended
COMECO reserves the right of changing specifications without prior notice!
d ≤ 6 mm
temperature probes
Ordering code
TSN(A,H,HA) - G1G2.G3.G4.G6.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option
Code values
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000
G3
Temperature range
T7 - 0…200 °C, T9 - -50…200 °C, T22 - 200…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T11 - 50…600 °C (4), T4 - 0…800 °C (4)
G4
Diameter 'd' [mm] (1)
3 (4), 4.5, 6, 8
G6
Probe length 'n' [mm]
50…50000
G8
Cable length 'k' [m] and type
X - no cable, 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1PV…10PV - PVC
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404
G11
Accuracy class
A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (4)
G14
Tip shape
X - standard (isolated from sheath), N - narrowed (2,4)
G15
Connector
#1
Options
(3)
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only) X - none, OS - cable protection SS spring (≈ 50 mm) (3), OB - braid termination lead (only w/o connector) (3)
(1)
Up to 6 mm for TSNH and TSNHA Only for TSN! Only for TSNA and TSNHA! (4) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
MINERAL-INSULATED THERMOCOUPLE PROBE
TSNx SENSITIVE ELEMENT
Sheath - see table Extension cable - see table notes
SHEATH MATERIAL M1
1 x J,
MI CABLE PROBE ONLY (TSN)
1 x T **
TEMPERATURE RANGE max. 400 °C
M2,M3,M9,M5,M8 M4
d [mm] 1, 1.5, 2, 3, 4.5, 6, 8, 10*
max. 800 °C
6, 8
M10 2xJ 2 x T **
n = 50 ... 50 000 mm 1 x K, 1 x N, 1 x E **
DESIGN WITH EXTENSION CABLE (TSNA)
M1 M2,M3,M9,M5,M8 M4 M2, M3, M9
max. 850 °C
M8 M4
2xK
M7*
2xN
M8 M4 M5
n = 50 ... 50 000 mm k = 1 … 10 m
d D
<6 6
6 8
8, 10 d
DESIGN WITH CONNECTOR (TSNH)
6, 8 1, 1.5, 2, 3, 4.5, 6, 8, 10*
M7*
M2, M3, M9
2 x S(R)
1.5, 2, 3, 4.5, 6, 8, 10*
max. 800 °C max. 400 °C
M10
1 x S(R),
max. 400 °C
M1
M5
2 x E **
3, 4.5, 6
M8
3, 6, 10* max. 1100 °C
max. 1150 °C
1, 1.5, 2, 3, 4.5, 6, 8, 10* 6, 8 1.5, 3, 4.5, 6, 8
max. 1250 °C
3, 4.5, 6
max. 850 °C
1.5, 3, 4.5, 6, 8
max. 1100 °C max. 1150 °C
3, 6, 10* 1.5, 3, 4.5, 6, 8 6, 8 1.5, 3, 4.5, 6, 8
max. 1100 °C
3, 4.5, 6
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4762 (M4), 1.4841 (M5), 1.4876 (M7), 2.4816 (M8), 1.4404 (M9), Nicrobell® (M10) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes)
n = 50 ... 50 000 mm
DESIGN WITH CONNECTOR AND EXTENSION CABLE (TSNHA)
Thermocouple connector: 'standard' (C5) or 'miniature' (C6) (see Appendix - Connectors) Temperature limitation: The temperature around TSNA holding tube and TSNH(A) connector must not exceed -50...200 °C!
n = 50 ... 50 000 mm
d ≤ 6 mm
k = 1 … 10 m
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
* Please contact COMECO! ** For T/C type "T": max. 400 °C; for T/C type "E": max. 1000 °C
COMECO reserves the right of changing specifications without prior notice!
Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)
d ≤ 6 mm
temperature probes
Ordering code
TSN(A,H,HA) - G1G2.G3.G4.G6.G8.G10.G11.G14.G15 - #1
Code Feature or option
Code values
G1
Number of thermocouples
1 or 2 (1)
G2
Thermocouple
E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T"
G3
Temperature range
T7 - 0…200 °C, T9 - -50…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T4 - 0…800 °C, T3 - 0…850 °C, T16 - 0…1100 °C, T6 - 0…1150(1250) °C
G4
Diameter 'd' [mm] (2)
1 (3), 1.5 (4), 2, 3, 4.5, 6, 8, 10
G6
Probe length 'n' [mm]
50…50000
G8
Cable length 'k' [m] and type
X - no cable, 1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®
G11
Accuracy class
1 - '1' (6), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
G15
Connector (5)
X - none, C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OS - cable protection SS spring (≈ 50 mm) (5), OB - braid termination lead (only w/o connector) (5)
(1)
Only for TSN. Ask for TSNA! Up to 6 mm for TSNH and TSNHA Always grounded (4) Grounded when G1="2" (5) Only for TSNA and TSNHA! (6) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
SCREW-IN MI RTD PROBE
TSNGx
Sheath - see table Extension cable - see table notes
STRAIGHT DESIGN (TSNG)
n = 50 ... 50 000 mm k = 1 … 10 m
EXTENDED DESIGN (TSNG1)
SENSITIVE ELEMENT
SHEATH TEMPERATURE MATERIAL RANGE **
1 x Pt (RB,RD,RF,RG)
M1, M2, M3, M5, M8, M9
2 x Pt (RB,RD,RF,RG)
M1, M2, M3, M5, M8, M9
T7 T8 T9 T22 T1 T11 T4
0...200 °C 0...400 °C -50...200 °C -200...200 °C -50...400 °C -50...600 °C 0...800 °C
DIMENSIONS d [mm]
wires
3*, 4.5, 6, 8
2, 3, 4*
2x2
4.5*, 6, 8
2x3*
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4841 (M5), 2.4816 (M8), 1.4404 (M9) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature ***) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature ***) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Tip shape: standard (see Appendix - Tip Shapes)
n = 50 ... 50 000 mm m = 60 ... 50 000 mm k = 1 … 10 m
Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Cable connector: 4-pin (C3) (see Appendix - Connectors) Temperature limitation: The temperature beyond the HEX body (SW) must not exceed -50...200 °C!
ANGLED DESIGN (TSNGL)
Available threads and HEX sizes:
SW
M6
M8
10
10
M10 1/8" 12(13)
M12 1/4" 14
M14 17
M16 3/8" 19
M18 22
* Please contact COMECO! n = 50 ... 50 000 mm k = 1 … 10 m
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
** Max. 550 °C (for chip RTD) or 800 °C (for wire-wound RTD) *** Sub-zero temperatures are not recommended
M20 1/2" 24
COMECO reserves the right of changing specifications without prior notice!
G
temperature probes
Ordering code
TSNG(G1,L) - G1G2.G3.G4.G6.G7.G8.G9.G10.G11.G12.G15 - #1
Code Feature or option
Code values
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000
G3
Temperature range
T7 - 0…200 °C, T9 - -50…200 °C, T22 - 200…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T11 - 50…600 °C (3), T4 - 0…800 °C (3)
G4
Diameter 'd' [mm]
3 (3), 4.5, 6, 8
G6
Probe length 'n' [mm]
50…50000
G7
Probe length 'm' [mm] (1)
60…50000
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (3), 1PV…10PV - PVC
G9
Mounting connection
Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q7 - M12x1.5, Q8 - M14x1.5, Q10 - 1/2" NPT, Q18 - G1/8", Q19 - 1/8" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Q26 - M8x1, Q29 - M8x1.25, Q30 - M10x1.5, Q31 - M6x1, Uxx - union nut (xx - same as for Qxx)
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M5 - 1.4841, M8 - 2.4816 (Inconel 600), M9 - 1.4404
G11
Accuracy class
A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (3)
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only)
#1
Options
X - none, OS - cable protection SS spring (≈ 50 mm) (2), OB - braid termination lead (only w/o connector)
(1)
Only for TSNG1! Only for TSNG! (3) Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
SCREW-IN MI THERMOCOUPLE PROBE
TSNGx
Sheath - see table Extension cable - see table notes
SENSITIVE ELEMENT
SHEATH MATERIAL
TEMPERATURE RANGE max. 400 °C
M1
STRAIGHT DESIGN (TSNG)
1 x J,
M2,M3,M9,M5,M8
1 x T **
M4
d [mm] 1.5, 2, 3, 4.5, 6, 8, 10*
max. 800 °C
6, 8
M10 max. 400 °C
M1
2xJ
M2,M3,M9,M5,M8
2 x T **
n = 50 ... 50 000 mm k = 1 … 10 m
3, 4.5, 6
max. 800 °C
M4 M1
max. 400 °C
M2, M3, M9
max. 850 °C
6, 8 1.5, 2, 3, 4.5, 6, 8, 10*
M7*
1 x K, 1 x N,
3, 6, 10* max. 1100 °C
M8
1 x E **
M4
EXTENDED DESIGN (TSNG1)
max. 1150 °C
M5 M10 2xK
M7*
2xN
M8
2 x E **
M4
1 x S(R),
3, 4.5, 6 1.5, 3, 4.5, 6, 8
max. 1150 °C
3, 6, 10* 1.5, 3, 4.5, 6, 8 6, 8 1.5, 3, 4.5, 6, 8
max. 1100 °C
M8
2 x S(R)
6, 8 1.5, 3, 4.5, 6, 8
max. 850 °C max. 1100 °C
M5
1.5, 2, 3, 4.5, 6, 8, 10*
max. 1250 °C
M2, M3, M9
n = 50 ... 50 000 mm m = 60 ... 50 000 mm k = 1 … 10 m
1.5, 2, 3, 4.5, 6, 8, 10*
3, 4.5, 6
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4762 (M4), 1.4841 (M5), 1.4876 (M7), 2.4816 (M8), 1.4404 (M9), Nicrobell® (M10) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature)
ANGLED DESIGN (TSNGL)
Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes)
n = 50 ... 50 000 mm k = 1 … 10 m
Thermocouple connector: 'standard' (C5) or 'miniature' (C6) (see Appendix - Connectors) Temperature limitation: The temperature beyond the HEX body (SW) must not exceed -50...200 °C! Available threads and HEX sizes: G SW
M6
M8
10
10
M10 1/8" 12(13)
M12 1/4" 14
M14 17
M16 3/8" 19
M18 22
M20 1/2" 24
* Please contact COMECO! ** For T/C type "T": max. 400 °C; for T/C type "E": max. 1000 °C
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)
temperature probes
Ordering code
TSNG(G1,L) - G1G2.G3.G4.G6.G7.G8.G9.G10.G11.G14.G15 - #1
Code Feature or option
Code values
G1
Number of thermocouples
1 or 2
G2
Thermocouple
E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T"
G3
Temperature range
T7 - 0…200 °C, T9 - -50…200 °C, T8 - 0…400 °C, T1 - -50…400 °C, T4 - 0…800 °C, T3 - 0…850 °C, T16 - 0…1100 °C, T6 - 0…1150(1250) °C
G4
Diameter 'd' [mm]
1.5 (1), 2, 3, 4.5, 6, 8
G6
Probe length 'n' [mm]
50…50000
G7
Probe length 'm' [mm] (2)
60…50000
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®
G9
Mounting connection
Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q7 - M12x1.5, Q8 - M14x1.5, Q10 - 1/2" NPT, Q18 - G1/8", Q19 - 1/8" NPT, Q20 - M10x1, Q23 - G1/4", Q24 - 1/4" NPT, Q26 - M8x1, Q29 - M8x1.25, Q30 - M10x1.5, Q31 - M6x1, Uxx - union nut (xx - same as for Qxx)
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®
G11
Accuracy class
1 - '1' (4), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
G15
Connector
X - none, C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OS - cable protection SS spring (≈ 50 mm) (3), OB - braid termination lead (only w/o connector)
(1)
Grounded when G1="2" Only for TSNG1! (3) Only for TSNG! (4) Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
(MI**) CLAMP CABLE PROBE FOR PIPE-SURFACE MEASUREMENT
TSTx
DIMENSIONS SENSITIVE ELEMENT
Sheath - stainless steel (see table notes) Clamp - see table notes Cable - see table notes
CABLE TYPE
TEMPERATURE RANGE
d [mm]
wires
RTD Design
STRAIGHT-TUBE DESIGN (TST)
4.5**, 5
2, 3*
6
2, 3, 4*
T7 T8
0...200 °C 0...400 °C
6
2x2
SLSL, TSL, YY, UU, YU
T9
-50...200 °C
GLGL, TT
T7
0...200 °C
SLSL, TSL, YY, UU, YU
T12
-50...100 °C
GLGL, TT
T19
0...100 °C
SLSL, TSL, YY, UU, YU
T9 T1*
2 x Pt (RB,RD,RF,RG)
GLGL, TT
1 x Cu (RH, RK) 2 x Cu (RH, RK) n = 20 … 100 mm D = 17 … 280 mm k = 1 … 10 m
-50...200 °C -50...400 °C
1 x Pt (RB,RD,RF,RG)
1 x PTC (RP, RQ)
5*
2, 3*
6
2, 3, 4*
6
2x2
6
2, 3
5, 6
2
4.5, 6
2
Regular Thermocouple Design
DESIGN WITH ANGLED TERMINATION (TSTL)
1 x J, 1 x K, 1xT
SLSL, TSL, YY, UU, YU
T9 T1*
GLGL, TT
T8
-50...200 °C -50...400 °C 0...400 °C
MI Thermocouple Design ** 1 x N, 1 x E, 1xT
SLSL, TSL, YY, UU, YU
T9 T1*
GLGL, TT
T8
-50...200 °C -50...400 °C 0...400 °C
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature)
Diameter 'D'
Average pipe OD
17...29 mm
22
25...45 mm
35
40...60 mm 63...83 mm
50 73
Tip shape: - RTD: standard - T/C: standard (isolated) or grounded (see Appendix - Tip Shapes) Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance)
78...98 mm
88
93...113 mm
103
108...128 mm
118
123...143 mm
133
138...158 mm 153...173 mm
148 163
168...188 mm
178
17...113 mm
8 mm or 14 mm
183...203 mm
193
108...280 mm
14 mm
198...218 mm
208
213...233 mm 228...248 mm
223 238
243...263 mm
253
258...280 mm
269
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors) Available clamp sizes: Diameter 'D'
Clamp width
- other on request
* Please contact COMECO! ** Available only for TSTL!
COMECO reserves the right of changing specifications without prior notice!
n = 20 … 100 mm D = 17 … 280 mm k = 1 … 10 m
temperature probes
Ordering code
TST(L) - (MI -(1)) G1G2.G3.G4.G5.G6.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option G1 G2
G3 G4
Code values
Number of sensors (3)
1 or 2 regular design
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP -PTC 1k, RQ - PTC 2k, J - T/C type "J", K - T/C type "K", T - T/C type "T"
MI design
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP -PTC 1k, RQ - PTC 2k, E - T/C type "E", N - T/C type "N", T - T/C type "T"
Sensor
T1 - -50…400 °C, T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T12 - 50…100 °C, T19 - 0…100 °C
Temperature range regular design
Diameter 'd' [mm]
MI design
5, 6 4.5, 6
G5
Clamp diameter 'D' (average pipe OD)
22 - 17…29 mm, 35 - 25…45 mm, 50 - 40…60 mm, 73 - 63…83 mm, 88 - 78…98 mm, 103 - 93…113 mm, 118 - 108…128 mm, 133 - 123…143 mm, 148 - 138…158 mm, 163 - 153…173 mm, 178 - 168…188 mm, 193 - 183…203 mm, 208 - 198…218 mm, 223 - 213…233 mm, 238 - 228…248 mm, 253 - 243…263 mm, 269 - 258…280 mm, Z - other on request (specify average pipe OD) (6)
G6
Probe length 'n' [mm]
20…100
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (6), 1PV…10PV - PVC
G10
Sheath material (wetted parts)
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
G11
Accuracy class
G12
Number of wires (3)
RTD
X - none (2), A - 'A', B - 'B', C - '2xB'
T/C
1 - '1' (6), 2 - '2' 2, 3, 4 (6)
(4)
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled) (5), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface (5)
(1)
Available only for TSTL! For non-Pt sensors Only for RTD sensors! (4) Only for thermocouples! (5) Only for non-MI (regular) design! (6) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
TOROIDAL CABLE PROBE
TSTO SENSITIVE ELEMENT
Sheath - stainless steel (see table notes) Cable - see table notes
CABLE TYPE
TEMPERATURE RANGE
DIMENSIONS d [mm]
wires
RTD Design -50...200 °C -50...100 °C
4, 5
2, 3*
6
2, 3, 4*
0...200 °C 0...400 °C
6
2x2
6
2, 3
5, 6
2
1 x Pt (RB,RD,RF,RG)
SLSL, TSL, YY, UU, YU
T9 T12
2 x Pt (RB,RD,RF,RG)
GLGL, TT
T7 T8
SLSL, TSL, YY, UU, YU
T12
-50...100 °C
GLGL, TT
T19
0...100 °C
1 x PTC (RP, RQ)
Thermocouple Design SLSL, TSL, YY, UU, YU
T9
-50...200 °C
1 x J, 1xT
GLGL, TT
T8
0...400 °C
1 x K,
n = 20 … 30 mm D = 8 … 24 mm k = 1 … 10 m
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9)
d [mm]
4
5
6
H [mm]
6
7
8
Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) Tip shape: - RTD: standard - T/C: standard (isolated) or grounded (see Appendix - Tip Shapes) Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors)
COMECO reserves the right of changing specifications without prior notice!
* Please contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
Ordering code
TSTO - G1G2.G3.G4.G5.G6.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option
Code values
G1
Number of sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RP -PTC 1k, RQ - PTC 2k, J - T/C type "J", K - T/C type "K", T - T/C type "T"
G3
Temperature range
T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T12 - 50…100 °C, T19 - 0…100 °C
G4
Diameter 'd' [mm]
4, 5, 6
G5
Toroid diameter 'D' [mm]
8…24
G6
Probe length 'n' [mm]
20…30
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1PV…10PV - PVC
G10
Sheath material (wetted parts)
G11
Accuracy class (2)
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
RTD
X - none (1), A - 'A', B - 'B', C - '2xB'
T/C
1 - '1' (4), 2 - '2' 2, 3, 4 (4)
G12
Number of wires
G14
Tip shape (hot junction) (3)
X - standard (isolated from sheath), G - grounded
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface
(1)
For non-Pt sensors Only for RTD sensors! Only for thermocouples! (4) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
FINGER CABLE PROBE FOR PIPE-SURFACE MEASUREMENT
TSY SENSITIVE ELEMENT
Sheath - stainless steel (see table notes) Cable - see table notes
CABLE TYPE
TEMPERATURE RANGE
WIRES
RTD Design -50...200 °C -50...100 °C
2, 3, 4*
0...200 °C 0...400 °C
2x2
1 x Pt (RB,RD,RF,RG)
SLSL, TSL, YY, UU, YU
T9 T12
2 x Pt (RB,RD,RF,RG)
GLGL, TT
T7 T8
SLSL, TSL, YY, UU, YU
T12
-50...100 °C
GLGL, TT
T19
0...100 °C
1 x PTC (RP, RQ)
2, 3
Thermocouple Design SLSL, TSL, YY, UU, YU
T9
-50...200 °C
1 x J, 1xT
GLGL, TT
T8
0...400 °C
1 x K,
2
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) n = 20 … 30 mm k = 1 … 10 m
Cable type: - GLGLP(V) (glass fiber w/ steel braid, max. 400 °C ambient temperature) - SLSL or TSL (silicone, max. 250 °C ambient temperature) - TT (Teflon®, max. 250 °C ambient temperature) - YY (PVC, max. 100 °C ambient temperature) - UU or YU (PUR, max. 80 °C ambient temperature) Tip shape: - RTD: standard - T/C: standard (isolated) or grounded (see Appendix - Tip Shapes) Accuracy class: - RTD: 'A', 'B', or '2xB' - T/C: '1' or '2' (see Appendix - RTD or T/C Tolerance) Cable connector: 4-pin (C3), 'T/C standard' (C5) or 'T/C miniature' (C6) (see Appendix - Connectors) * Please contact COMECO!
TSY - G1G2.G3.G6.G8.G10.G11.G12.G14.G15 - #1
Code Feature or option
Code values
G1
Number of sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RP -PTC 1k, RQ - PTC 2k, J - T/C type "J", K - T/C type "K", T - T/C type "T"
G3
Temperature range
T7 - 0…200 °C, T8 - 0…400 °C, T9 - -50…200 °C, T12 - 50…100 °C, T19 - 0…100 °C
G6
Probe length 'n' [mm]
20…30
G8
Cable length 'k' [m] and type
1GL…10GL - glass fiber, 1SL…10SL - silicone, 1TF…10TF - Teflon®, 1PU…10PU - polyurethane (4), 1PV…10PV - PVC
G10
Sheath material (wetted parts)
G11
Accuracy class (2)
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
RTD
X - none (1), A - 'A', B - 'B', C - '2xB'
T/C
1 - '1' (4), 2 - '2' 2, 3, 4 (4)
G12
Number of wires
G14
Tip shape (hot junction) (3)
X - standard (isolated from sheath), G - grounded
G15
Connector
X - none, C3 - 4-pin male plug-in connector ø8 (for H5700 thermometer only), C5 - T/C connector, C6 - miniature T/C connector
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled), OS - cable protection SS spring (≈ 50 mm), OB - braid termination lead (only w/o connector), OP - electrochemically polished sheath surface
(1)
For non-Pt sensors Only for RTD sensors! Only for thermocouples! (4) Contact COMECO! (2) (3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
temperature probes
(MI) RTD REPLACEABLE INSERT - PREPARED FOR IN-HEAD TRANSMITTER ** Sheath - stainless steel (see Appendix - Sheath materials) Terminal base - Al2O3. Terminals - Ni-plated brass
TSSx TSOSx
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
n [mm]
d [mm]
wires
Regular Design
DESIGN WITH TERMINAL BLOCK TYPE "M" (TS(O)SM) 1 x Pt (RB,RD,RF,RG)
2 x Pt (RB,RD,RF,RG) 3 x Pt * (RB,RD,RF,RG) 1 x Cu (RH, RK) 2 x Cu (RH, RK) 1 x PTC (RP, RQ)
T9 T1 T24 T11 T2 T4 T22 T9
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C -50...200 °C
T9
-50...200 °C
T12
-50...100 °C
50…200
4
2
50…500
5
2, 3*
50…1500
6
2, 3, 4*
50…3000
8
2, 3, 4
50…3000
6, 8, 10
2x2, 2x3*
50…3000
8, 10
3x2
50…1500
6
2, 3, 4*
8
2, 3, 4
50…3000 50…3000
2 x PTC (RP, RQ)
6
2x2*
8
2x2(3)*
50…1500
6
50…3000
8, 10
50…3000
8, 10
2, 3 2x2
MI Design 1 x Pt (RB,RD,RF,RG)
DESIGN WITH TERMINAL BLOCK TYPE "B" (TS(O)SB) 2 x Pt (RB,RD,RF,RG)
T9 T1 T24 T11 T2 T4 T22
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C
50...50000
50...50000
3*
2, 3*
4.5
2, 3*
6
2, 3, 4*
8
2, 3, 4
6, 8
2x2, 2x3*
Suitable protection heads: (see Appendix - Protection Heads) - TS(O)SM: heads with 20 mm mounting distance - TS(O)SB: heads with 33 mm mounting distance Fixing to protection head: direct (default) or springing ('OS' option) Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes) Sheath material: 1.4301(M1), 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362 (M15)
Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance)
* Please contact COMECO! ** No transmitter mounted!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Wire material: Cu, Ni, or Ag
temperature probes
Ordering code
TS (B, M) - (MI -) G1G2.G3.G4.G6.G10.G11.G12.G13.G14 - #1
Code Feature or option
Code values
Base model variant
S - standard (w/ terminal block), OS - prepared for in-head transmitter (w/o terminal block)
G1
Number of RTD sensors
1, 2, or 3 (7)
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP - PTC 1k, RQ - PTC 2k
G3
Temperature range
T1 - -50…400 °C, T2 - -200…600 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C, T22 - -200…200 °C, T24 - -50…500 °C
G4
Diameter 'd' [mm]
G6
Insert length 'n' [mm]
regular design
4, 5, 6, 8, 10
MI design
3 (7), 4.5, 6, 8
(1)
50…50000 (see table overleaf) regular design
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404, M15 - 1.4362
G10
Sheath material (wetted parts)
G11
Accuracy class
X - none (2), A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (7)
(3)
MI design
M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
CU - copper (4), NI - nickel, AG - silver (5)
G13
Wire material
G14
Tip shape
X - standard closed, N - narrowed (5), P - pitted (5)
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled) (5,6), OS - spring-fixed terminal block, OP - electrochemically polished sheath surface (5)
(1)
This length does not coincide with the probe immersion length! For non-Pt sensors Only for Pt sensors! (4) Not applicable to non-MI (regular) RTDs for above 500 °C! (5) Only for non-MI (regular) design! (6) Requires 'OS' option! (7) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
(MI) T/C REPLACEABLE INSERT - PREPARED FOR IN-HEAD TRANSMITTER ** Sheath - stainless steel (see Appendix - Sheath materials) Terminal base - Al2O3. Terminals - Ni-plated brass
TSSx TSOSx
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
n [mm]
d [mm]
wires
Regular Design
DESIGN WITH TERMINAL BLOCK TYPE "M" (TS(O)SM)
50...1500
6
50...3000
8, 10
50...1500
6
50...3000
8, 10
1(2) x J 1(2) x L
T4
0...800 °C
1(2) x K
T3 T16 T6*
0...850 °C 0...1100 °C 0...1150 °C
1(2) x E
T3 T13
0...850 °C 0...1000 °C
50...1500
6
50...3000
8, 10
1(2) x S 1(2) x R
T16 T6*
0...1100 °C 0...1150 °C
50...1500
6
50...3000
8, 10
2 (2x2) 2 (2x2) 2 (2x2) 2 (2x2)
MI Design 1xJ
0...800 °C
50...50000
3, 4.5, 6, 8
T8
0...400 °C
50...50000
3, 4.5, 6, 8
0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C
50...50000
3, 4.5, 6, 8
2
2xK 2 x N, 2 x E
T3 T16 T6* T6*
50...50000
3, 4.5, 6, 8
2x2
2xS 2xR
T16 T6*
0...1100 °C 0...1150 °C
50...10000
3, 4.5, 6
2x2
1xT 2xT 1xK 1 x N, 1 x E
DESIGN WITH TERMINAL BLOCK TYPE "B" (TS(O)SB)
2
T4
2xJ
2x2 2 2x2
Suitable protection heads: (see Appendix - Protection Heads) - TS(O)SM: heads with 20 mm mounting distance - TS(O)SB: heads with 33 mm mounting distance Fixing to protection head: direct (default) or springing ('OS' option) Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Sheath material: 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362 (M15)
Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)
* Please contact COMECO! ** No transmitter mounted!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
MI sheath material: 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4876(M7), 2.4816(M8), Nicrobell® (M10)
temperature probes
Ordering code
TS (B, M) - (MI -) G1G2.G3.G4.G6.G10.G11.G14 - #1
Code Feature or option
Code values
Base model variant
S - standard (w/ terminal block), OS - prepared for in-head transmitter (w/o terminal block)
G1
Number of thermocouples
1 or 2
G2
Thermocouple
G3
Temperature range
G4
Diameter 'd' [mm]
G6
Insert length 'n' [mm] (1)
G10
Sheath material (wetted parts)
regular design
E - type "E", J - type "J", K - type "K", L - type "L", R - type "R", S - type "S"
MI design
E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T" T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (4), T13 - 0…1000 °C, T16 - 0…1100 °C
regular design
6, 8, 10
MI design
3, 4.5, 6, 8
regular design
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762, M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4404, M15 - 1.4362
MI design
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®
50…50000 (see table overleaf)
G11
Accuracy class
1 - '1' (4), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
#1
Options
X - none, OV - vibration proof (secured screws) (2,3), OS - spring-fixed terminal block, OP - electrochemically polished sheath surface (2)
(1)
This length does not coincide with the probe immersion length! Only for non-MI (regular) design! Requires 'OS' option! (4) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
(MI) RTD REPLACEABLE INSERT - PREPARED FOR IN-HEAD TRANSMITTER ** Sheath - stainless steel (see Appendix - Sheath materials) Terminal base - Al2O3. Terminals - Ni-plated brass
TSSx TSOSx
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
n [mm]
d [mm]
wires
Regular Design
DESIGN WITH TERMINAL BLOCK TYPE "M" (TS(O)SM) 1 x Pt (RB,RD,RF,RG)
2 x Pt (RB,RD,RF,RG) 3 x Pt * (RB,RD,RF,RG) 1 x Cu (RH, RK) 2 x Cu (RH, RK) 1 x PTC (RP, RQ)
T9 T1 T24 T11 T2 T4 T22 T9
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C -50...200 °C
T9
-50...200 °C
T12
-50...100 °C
50…200
4
2
50…500
5
2, 3*
50…1500
6
2, 3, 4*
50…3000
8
2, 3, 4
50…3000
6, 8, 10
2x2, 2x3*
50…3000
8, 10
3x2
50…1500
6
2, 3, 4*
8
2, 3, 4
50…3000 50…3000
2 x PTC (RP, RQ)
6
2x2*
8
2x2(3)*
50…1500
6
50…3000
8, 10
50…3000
8, 10
2, 3 2x2
MI Design 1 x Pt (RB,RD,RF,RG)
DESIGN WITH TERMINAL BLOCK TYPE "B" (TS(O)SB) 2 x Pt (RB,RD,RF,RG)
T9 T1 T24 T11 T2 T4 T22
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C
50...50000
50...50000
3*
2, 3*
4.5
2, 3*
6
2, 3, 4*
8
2, 3, 4
6, 8
2x2, 2x3*
Suitable protection heads: (see Appendix - Protection Heads) - TS(O)SM: heads with 20 mm mounting distance - TS(O)SB: heads with 33 mm mounting distance Fixing to protection head: direct (default) or springing ('OS' option) Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes) Sheath material: 1.4301(M1), 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362 (M15)
Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance)
* Please contact COMECO! ** No transmitter mounted!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Wire material: Cu, Ni, or Ag
temperature probes
Ordering code
TS (B, M) - (MI -) G1G2.G3.G4.G6.G10.G11.G12.G13.G14 - #1
Code Feature or option
Code values
Base model variant
S - standard (w/ terminal block), OS - prepared for in-head transmitter (w/o terminal block)
G1
Number of RTD sensors
1, 2, or 3 (7)
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP - PTC 1k, RQ - PTC 2k
G3
Temperature range
T1 - -50…400 °C, T2 - -200…600 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C, T22 - -200…200 °C, T24 - -50…500 °C
G4
Diameter 'd' [mm]
G6
Insert length 'n' [mm]
regular design
4, 5, 6, 8, 10
MI design
3 (7), 4.5, 6, 8
(1)
50…50000 (see table overleaf) regular design
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404, M15 - 1.4362
G10
Sheath material (wetted parts)
G11
Accuracy class
X - none (2), A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (7)
(3)
MI design
M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
CU - copper (4), NI - nickel, AG - silver (5)
G13
Wire material
G14
Tip shape
X - standard closed, N - narrowed (5), P - pitted (5)
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled) (5,6), OS - spring-fixed terminal block, OP - electrochemically polished sheath surface (5)
(1)
This length does not coincide with the probe immersion length! For non-Pt sensors Only for Pt sensors! (4) Not applicable to non-MI (regular) RTDs for above 500 °C! (5) Only for non-MI (regular) design! (6) Requires 'OS' option! (7) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
(MI) T/C REPLACEABLE INSERT - PREPARED FOR IN-HEAD TRANSMITTER ** Sheath - stainless steel (see Appendix - Sheath materials) Terminal base - Al2O3. Terminals - Ni-plated brass
TSSx TSOSx
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
n [mm]
d [mm]
wires
Regular Design
DESIGN WITH TERMINAL BLOCK TYPE "M" (TS(O)SM)
50...1500
6
50...3000
8, 10
50...1500
6
50...3000
8, 10
1(2) x J 1(2) x L
T4
0...800 °C
1(2) x K
T3 T16 T6*
0...850 °C 0...1100 °C 0...1150 °C
1(2) x E
T3 T13
0...850 °C 0...1000 °C
50...1500
6
50...3000
8, 10
1(2) x S 1(2) x R
T16 T6*
0...1100 °C 0...1150 °C
50...1500
6
50...3000
8, 10
2 (2x2) 2 (2x2) 2 (2x2) 2 (2x2)
MI Design 1xJ
0...800 °C
50...50000
3, 4.5, 6, 8
T8
0...400 °C
50...50000
3, 4.5, 6, 8
0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C
50...50000
3, 4.5, 6, 8
2
2xK 2 x N, 2 x E
T3 T16 T6* T6*
50...50000
3, 4.5, 6, 8
2x2
2xS 2xR
T16 T6*
0...1100 °C 0...1150 °C
50...10000
3, 4.5, 6
2x2
1xT 2xT 1xK 1 x N, 1 x E
DESIGN WITH TERMINAL BLOCK TYPE "B" (TS(O)SB)
2
T4
2xJ
2x2 2 2x2
Suitable protection heads: (see Appendix - Protection Heads) - TS(O)SM: heads with 20 mm mounting distance - TS(O)SB: heads with 33 mm mounting distance Fixing to protection head: direct (default) or springing ('OS' option) Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Sheath material: 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362 (M15)
Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)
* Please contact COMECO! ** No transmitter mounted!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
MI sheath material: 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4876(M7), 2.4816(M8), Nicrobell® (M10)
temperature probes
Ordering code
TS (B, M) - (MI -) G1G2.G3.G4.G6.G10.G11.G14 - #1
Code Feature or option
Code values
Base model variant
S - standard (w/ terminal block), OS - prepared for in-head transmitter (w/o terminal block)
G1
Number of thermocouples
1 or 2
G2
Thermocouple
G3
Temperature range
G4
Diameter 'd' [mm]
G6
Insert length 'n' [mm] (1)
G10
Sheath material (wetted parts)
regular design
E - type "E", J - type "J", K - type "K", L - type "L", R - type "R", S - type "S"
MI design
E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T" T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (4), T13 - 0…1000 °C, T16 - 0…1100 °C
regular design
6, 8, 10
MI design
3, 4.5, 6, 8
regular design
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762, M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4404, M15 - 1.4362
MI design
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®
50…50000 (see table overleaf)
G11
Accuracy class
1 - '1' (4), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
#1
Options
X - none, OV - vibration proof (secured screws) (2,3), OS - spring-fixed terminal block, OP - electrochemically polished sheath surface (2)
(1)
This length does not coincide with the probe immersion length! Only for non-MI (regular) design! Requires 'OS' option! (4) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes (MI) RTD PROBE WITH PROTECTION HEAD
TSCx
- FOR IN-HEAD TRANSMITTER ** TSOCx Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum, stainless steel, iron, or plastic (see Appendix - Protection heads)
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
n [mm]
d [mm]
wires
Regular Design
DESIGN WITHOUT EXTENSION (TS(O)C)
1 x Pt (RB,RD,RF,RG)
2(3) x Pt (RB,RD,RF,RG)
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C
1 x Cu (RH, RK)
T9
-50...200 °C
2 x Cu (RH, RK)
T9
-50...200 °C
T12
-50...100 °C
1 x PTC (RP, RQ)
EXTENDED DESIGN WITH WELDED CONNECTION (TS(O)C1)
T9 T1 T24 T11 T2 T4 T22
2 x Pt (RB,RD,RF,RG)
T9 T1 T24 T11 T2 T4 T22
50…1500
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C
2, 3* 2, 3, 4*
50…3000 8, 10, 12, 14, 16, 20
2, 3, 4
6*, 8, 10
2x2(3)*
12, 14, 16, 20
2x2(3), 3x2
50…3000 50…1500
6
2, 3, 4*
50…3000 8, 10, 12, 14, 16, 20 50…3000
50…1500 50…3000 50…3000 MI Design
2 x PTC (RP, RQ)
1 x Pt (RB,RD,RF,RG)
4 5 6
50…500
8, 10 12, 14, 16, 20 6 8, 10, 12, 14 8, 10, 12, 14
2x2 2x2(3)*
3*
2, 3*
50...50000
50...50000
2, 3 2x2
4.5
2, 3*
6
2, 3, 4*
8
2, 3, 4
6, 8
2x2, 2x3*
Protection head: B, MA, MB, G, N, Cx, Dx, Ex (see Appendix - Protection Heads)
EXTENDED DESIGN WITH MOVABLE CONNECTION (TS(O)C2)
Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Thermal isolation between nipple and metal head: (for TS(O)C only) Protection head MA, MB B other
Maximum temperature 200 °C 400 °C
Insulation material POM Teflon®
Extension length: m = 0…1500 mm Extension diameter: (for TS(O)C1 and TS(O)C2 only, [mm]) Probe diameter 'd' Ext. length 'm' up to 50 mm 50...150 mm 150...500 mm 500+ mm
3, 4 mm
4.5...6 mm
8 mm
10 mm
10+ mm
8 8 10 14
d 8 10 14
d d 10 14
d d d 14
d d d d
Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes) Process pressure:
DESIGN WITH GLAND-TYPE CONNECTION (TS(O)C4)
Probe design Max. pressure *
TS(O)C, TS(O)C1 25 bar
TS(O)C2 16 bar
TS(O)C4 6 bar
TS(O)C3 0 bar
Sheath material: 1.4301(M1), 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362(M15) Wire material: Cu, Ni, or Ag Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) * Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
DESIGN WITH ADJUSTABLE CONNECTION (TS(O)C3)
Length 'n' up to 50 mm up to 100 mm up to 150 mm
temperature probes
Ordering code
TS (1,2,3,4) - (MI -) G0.G1G2.G3.G4.G6.G7.G9'9".G10.G11.G12.G13.G14 - #1.#2
Code Feature or option
Code values
Base model variant
C - standard (w/ terminal block), OC - prepared for in-head transmitter (w/o terminal block)
G0
Protection head
B - type "B", CC - type "CC", CS - type "CS", D - type "D", DH - type "DH", DHW - type "DHW", DW - type "DW", E - type "E", EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", ES - type "ES", G - type "G", MA - type "MA", MB - type "MB", N - type "N"
G1
Number of RTD sensors
1, 2, or 3 (11)
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP - PTC 1k, RQ - PTC 2k
G3
Temperature range
T1 - -50…400 °C, T2 - -200…600 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C, T22 - -200…200 °C, T24 - -50…500 °C
G4
Diameter 'd' [mm]
regular design
4, 5, 6, 8, 10, 12, 14, 16, 20
MI design
3 (11), 4.5, 6, 8
(1)
G6
Probe length 'n' [mm]
G7
Probe length 'm' [mm] (2)
0…1500
50…50000 (see table overleaf)
G9'
Mounting connection
X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9"
Compression fitting ferrule (4)
BR - brass, GR - graphite, SS - stainless steel, TF - Teflon®
regular design
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404), M15 - 1.4362 (11)
MI design
M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404)
G10
Sheath material (wetted parts)
G11
Accuracy class
X - none (5), A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (11)
(6)
CU - copper (7), NI - nickel, AG - silver (8)
G13
Wire material
G14
Tip shape
X - standard closed, N - narrowed (8), P - pitted (8)
#1
Options
X - none, OV - vibration proof (spring terminals, MgO or Silicone filled, secured screws) (8), OT - thermal isolation (3), OP - electrochemically polished sheath surface (8)
#2
Incorporated devices
X - none, T - in-head transmitter (9), A - local indicator (10)
(1)
'n+m' for TS(O)C3 and TS(O)C4! Only for TS(O)C1 and TS(O)C2! Only for TS(O)C! (4) Only for TS(O)C4! (5) For non-Pt sensors (6) Only for Pt sensors! (7) Not applicable to non-MI (regular) RTDs for above 500 °C! (8) Only for non-MI (regular) design! (9) Only for variant 'OC'! See transmitter datasheets and order separately! (10) With windowed head only! See indicator datasheets and order separately! (11) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes (MI) T/C PROBE WITH PROTECTION HEAD
TSCx
- FOR IN-HEAD TRANSMITTER ** TSOCx Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum, stainless steel, iron, or plastic (see Appendix - Protection heads)
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
n [mm]
d [mm]
wires
50...1500 50...3000
6 8, 10, 12, 14, 16, 20, 22
2 (2x2)
50...1500
6
50...3000
8, 10, 12, 14, 16, 20, 22
Regular Design
DESIGN WITHOUT EXTENSION (TS(O)C)
1(2) x J 1(2) x L
T4
0...800 °C
1(2) x K
T3 T16 T6*
0...850 °C 0...1100 °C 0...1150 °C
1(2) x E
T3 T13
0...850 °C 0...1000 °C
50...1500
6
50...3000
8, 10, 12, 14, 16, 20, 22
1(2) x S 1(2) x R
T16 T6*
0...1100 °C 0...1150 °C
50...1500
6
50...3000
8, 10, 12, 14, 16, 20, 22
2 (2x2) 2 (2x2) 2 (2x2)
MI Design
EXTENDED DESIGN WITH WELDED CONNECTION (TS(O)C1)
1xJ 2xJ 1xT 2xT
2 2x2 2 2x2
T4
0...800 °C
50...50000
3, 4.5, 6, 8, 10*
T8
0...400 °C
50...50000
3, 4.5, 6, 8, 10*
0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C
50...50000
3, 4.5, 6, 8, 10*
2
2xK 2 x N, 2 x E
T3 T16 T6* T6*
50...50000
3, 4.5, 6, 8, 10*
2x2
2xS 2xR
T16 T6*
0...1100 °C 0...1150 °C
50...10000
3, 4.5, 6
2x2
1xK 1 x N, 1 x E
Protection head: B, MA, MB, G, N, Cx, Dx, Ex (see Appendix - Protection Heads)
EXTENDED DESIGN WITH MOVABLE CONNECTION (TS(O)C2)
Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Thermal isolation between nipple and metal head: (for TS(O)C only) Protection head MA, MB B other
Length 'n' up to 50 mm up to 100 mm up to 150 mm
Maximum temperature 200 °C 400 °C
Insulation material POM Teflon®
Extension length: m = 0…1500 mm Extension diameter: (for TS(O)C1 and TS(O)C2 only, [mm]) Probe diameter 'd' Ext. length 'm' up to 50 mm 50...150 mm 150...500 mm 500+ mm
3 mm
4.5, 6 mm
8 mm
10 mm
10+ mm
6 8 10 14
d 8 10 14
d d 10 14
d d d 14
d d d d
Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Process pressure: Probe design Max. pressure *
DESIGN WITH GLAND-TYPE CONNECTION (TS(O)C4)
TS(O)C, TS(O)C1 25 bar
TS(O)C2 16 bar
TS(O)C4 6 bar
TS(O)C3 0 bar
Sheath material: 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362 (M15) MI sheath material: 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4876(M7), 2.4816(M8), Nicrobell® (M10) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) * Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
DESIGN WITH ADJUSTABLE CONNECTION (TS(O)C3)
temperature probes
Ordering code
TS (1,2,3,4) - (MI -) G0.G1G2.G3.G4.G6.G7.G9'9".G10.G11.G14 - #1.#2
Code Feature or option
Code values
Base model variant
C - standard (w/ terminal block), OC - prepared for in-head transmitter (w/o terminal block)
G0
Protection head
B - type "B", CC - type "CC", CS - type "CS", D - type "D", DH - type "DH", DHW - type "DHW", DW - type "DW", E - type "E", EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", ES - type "ES", G - type "G", MA - type "MA", MB - type "MB", N - type "N"
G1
Number of thermocouples
1 or 2
G2
Thermocouple
G3
Temperature range
G4
Diameter 'd' [mm]
G6
Probe length 'n' [mm] (1)
50…50000 (see table overleaf)
G7
Probe length 'm' [mm] (2)
0…1500
G9'
Mounting connection
X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9"
Compression fitting ferrule (4)
BR - brass, GR - graphite, SS - stainless steel, TF - Teflon®
G10
Sheath material (wetted parts)
regular design
E - type "E", J - type "J", K - type "K", L - type "L", R - type "R", S - type "S"
MI design
E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T" T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (8), T13 - 0…1000 °C, T16 - 0…1100 °C
regular design MI design
6, 8, 10, 12, 14, 16, 20, 22 3, 4.5, 6, 8, 10
regular design
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762, M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4401 (1.4404), M15 - 1.4362
MI design
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4401 (1.4404), M10 - Nicrobell®
G11
Accuracy class
1 - '1' (8), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
#1
Options
X - none, OV - vibration proof (spring terminals (8), secured screws), OT - thermal isolation (3), OP - electrochemically polished sheath surface (5)
#2
Incorporated devices
X - none, T - in-head transmitter (6), A - local indicator (7)
(1)
'n+m' for TS(O)C3 and TS(O)C4! Only for TS(O)C1 and TS(O)C2! Only for TS(O)C! (4) Only for TS(O)C4! (5) Only for non-MI (regular) design! (6) Only for variant 'OC'! See transmitter datasheets and order separately! (7) With windowed head only! See indicator datasheets and order separately! (8) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes RTD PROBE WITH PROTECTION HEAD AND (MI) INSERT
TSCSx
- FOR IN-HEAD TRANSMITTER ** TSOCSx Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum, stainless steel, or plastic (see Appendix - Protection heads)
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
d [mm]
d insert [mm]
wires
Regular Insert Design
DESIGN WITHOUT EXTENSION (TS(O)CS)
1 x Pt (RB,RD,RF,RG)
2 x Pt (RB,RD,RF,RG) 1 x Cu (RH, RK) 2 x Cu (RH, RK)
EXTENDED DESIGN WITH WELDED CONNECTION (TS(O)CS1) 1 x Pt (RB,RD,RF,RG)
2 x Pt (RB,RD,RF,RG)
T9 T1 T24 T11 T2 T4 T22 T9 T9
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C -50...200 °C -50...200 °C
8
4, 5
2, 3*
9, 10, 12, 14, 16, 20
6
2, 3, 4*
12, 14, 16, 20
8
2, 3, 4
9, 10, 12, 14, 16, 20
6
2x2*
12, 14, 16, 20
8
2x2(3)*
9, 10, 12, 14, 16, 20
6
2, 3, 4*
12, 14, 16, 20
8
2, 3, 4
9, 10, 12, 14, 16, 20
6
2x2*
12, 14, 16, 20
8
2x2(3)*
3*
2, 3*
4.5
2, 3*
6
2, 3, 4*
MI Insert Design 6, 8, 9, 10, 12, 14, T9 -50...200 °C 16, 20 T1 -50...400 °C 8, 9, 10, 12, 14, T24 -50...500 °C 16, 20 T11 -50...600 °C 9, 10, 12, 14, 16, 20 T2 -200...600 °C 12, 14, 16, 20 0...800 °C 9, 10, 12, 14, 16, 20 T4 T22 -200...200 °C 12, 14, 16, 20
8
2, 3, 4
6
2x2, 2x3*
8
2x2, 2x3*
Protection head: B, MA, MB, G, N, Cx, Dx, Ex (see Appendix - Protection Heads)
EXTENDED DESIGN WITH MOVABLE CONNECTION (TS(O)CS2)
Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Thermal isolation between nipple and metal head: (for TS(O)CS only) Protection head
DESIGN WITH ADJUSTABLE CONNECTION (TS(O)CS3)
Length 'n'
Maximum temperature
Insulation material
MA, MB B
up to 50 mm up to 100 mm
200 °C
POM
other
up to 150 mm
400 °C
Teflon®
Extension length: m = 0…1500 mm Probe diameter 'd' Ext. length 'm'
6 mm
8 mm
9, 10 mm
10+ mm
up to 50 mm
d
d
d
d
50...150 mm
8
d
d
d
150...500 mm
10
10
d
d
500+ mm
14
14
14
d
Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes)
DESIGN WITH GLAND-TYPE CONNECTION (TS(O)CS4)
Process pressure: Probe design Max. pressure *
TS(O)CS, TS(O)CS1 TS(O)CS2 25 bar
16 bar
TS(O)CS4
TS(O)CS3
6 bar
0 bar
Sheath material: 1.4301(M1), 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362(M15) Wire material: Cu, Ni, or Ag Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) * Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Extension diameter: (for TS(O)CS1 and TS(O)CS2 only, [mm])
temperature probes
Ordering code
TS (1,2,3,4) - (MI -) G0.G1G2.G3.G4.G6.G7.G9'9".G10.G11.G12.G13.G14 - #1.#2
Code Feature or option
Code values
Base model variant
CS - standard (w/ terminal block), OCS - prepared for in-head transmitter (w/o terminal block)
Protection head
B - type "B", CC - type "CC", CS - type "CS", D - type "D", DH - type "DH", DHW - type "DHW", DW - type "DW", E - type "E", EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", ES - type "ES", G - type "G", MA - type "MA", MB - type "MB", N - type "N"
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100
G3
Temperature range
T1 - -50…400 °C, T2 - -200…600 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C, T22 - -200…200 °C, T24 - -50…500 °C
G4
Diameter 'd' / 'd insert' [mm]
G6
Probe length 'n' [mm] (1)
G0
G7
Probe length 'm' [mm]
regular insert
8/4, 8/5, 9/6, 10/6, 12/6, 14/6, 12/8, 14/8, 16/6, 16/8, 20/6, 20/8
MI insert
6/3 (12), 8/4.5, 9/6, 10/6, 12/6, 14/6, 16/6, 16/8, 20/6, 20/8 50…3000
(2)
0…1500
G9'
Mounting connection
X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9"
Compression fitting ferrule (4)
TF - Teflon®, BR - brass, SS - stainless steel
G10
Sheath material (wetted parts and insert)
G11
Accuracy class
X - none (5), A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (12)
G13
Wire material (6)
CU - copper (7), NI - nickel, AG - silver (8)
G14
Tip shape
X - standard closed, N - narrowed (12), P - pitted
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled insert, secured screws) (8,9), OS - spring-loaded insert, OT - thermal isolation (3), OP - electrochemically polished wetted parts
#2
Incorporated devices
X - none, T - in-head transmitter (10), A - local indicator (11)
regular insert
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404), M15 - 1.4362 (12)
MI insert
M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404)
(1)
'n+m' for TS(O)CS3 and TS(O)CS4! Only for TS(O)CS1 and TS(O)CS2! Only for TS(O)CS! (4) Only for TS(O)CS4! (5) For non-Pt sensors (6) Only for Pt sensors! (7) Not applicable to non-MI (regular) RTD inserts for above 500 °C! (8) Only for non-MI (regular) inserts! (9) Requires 'OS' option! (10) Only for variant 'OCS'! See transmitter datasheets and order separately! (11) With windowed head only! See indicator datasheets and order separately! (12) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes T/C PROBE WITH PROTECTION HEAD AND (MI) INSERT
TSCSx
- FOR IN-HEAD TRANSMITTER ** TSOCSx Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum, stainless steel, or plastic (see Appendix - Protection heads)
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
d [mm]
d insert [mm]
wires
Regular Insert Design
DESIGN WITHOUT EXTENSION (TS(O)CS)
10, 12, 14, 16, 20
6, 8, 10
2
12, 14, 16, 20
8, 10
2x2
0...850 °C 0...1100 °C 0...1150 °C
10, 12, 14, 16, 20
6, 8, 10
2
12, 14, 16, 20
8, 10
2x2
0...850 °C 0...1000 °C
10, 12, 14, 16, 20
6, 8, 10
2
2xE
T3 T13
12, 14, 16, 20
8, 10
2x2
1xS 1xR
T16 T6*
0...1100 °C 0...1150 °C
10, 12, 14, 16, 20
6, 8, 10
2
2xS 2xR
T16 T6*
0...1100 °C 0...1150 °C
12, 14, 16, 20
8, 10
2x2
1 x J; 1 x L 2 x J; 2 x L 1xK 2xK 1xE
EXTENDED DESIGN WITH WELDED CONNECTION (TS(O)CS1)
T4
0...800 °C
T3 T16 T6*
MI Insert Design 1xJ 2xJ 1xK 1 x N, 1 x E 2xK 2 x N, 2 x E
T4
0...800 °C
6, 8, 10, 12, 14, 16, 20
3, 4.5, 6, 8
T3 T16 T6* T6*
0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C
8, 10, 12, 14, 16, 20
4.5, 6, 8
2 2x2 2 2x2
Protection head: B, MA, MB, G, N, Cx, Dx, Ex (see Appendix - Protection Heads)
EXTENDED DESIGN WITH MOVABLE CONNECTION (TS(O)CS2)
Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Thermal isolation between nipple and metal head: (for TS(O)CS only) Protection head
DESIGN WITH ADJUSTABLE CONNECTION (TS(O)CS3)
Length 'n' up to 50 mm
Maximum temperature
B
up to 100 mm
200 °C
POM
other
up to 150 mm
400 °C
Teflon®
MA, MB
Insulation material
Process length: n = 50…3000 mm Extension length: m = 0…1500 mm Probe diameter 'd' Ext. length 'm'
DESIGN WITH GLAND-TYPE CONNECTION (TS(O)CS4)
6 mm
8 mm
10 mm
10+ mm d
up to 50 mm
d
d
d
50...150 mm
8
d
d
d
150...500 mm
10
10
d
d
500+ mm
14
14
14
d
Insert tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Process pressure: Probe design Max. pressure *
TS(O)CS, TS(O)CS1 TS(O)CS2 25 bar
16 bar
TS(O)CS4
TS(O)CS3
6 bar
0 bar
Sheath material: 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762/1.4749(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362(M15) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) * Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Extension diameter: (for TS(O)CS1 and TS(O)CS2 only, [mm])
temperature probes
Ordering code
TS (1,2,3,4) - (MI -) G0.G1G2.G3.G4.G6.G7.G9'9".G10.G11.G14 - #1.#2
Code Feature or option
Code values
Base model variant
CS - standard (w/ terminal block), OCS - prepared for in-head transmitter (w/o terminal block)
G0
Protection head
B - type "B", CC - type "CC", CS - type "CS", D - type "D", DH - type "DH", DHW - type "DHW", DW - type "DW", E - type "E", EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", ES - type "ES", G - type "G", MA - type "MA", MB - type "MB", N - type "N"
G1
Number of thermocouples
1 or 2 regular insert
E - type "E", J - type "J", K - type "K", L - type "L", R - type "R", S - type "S"
MI insert
E - type "E", J - type "J", K - type "K", N - type "N"
G2
Thermocouple
G3
Temperature range
G4
Diameter 'd' / 'd insert' [mm]
G6
Probe length 'n' [mm] (1)
50…3000
G7
Probe length 'm' [mm] (2)
0…1500
G9'
Mounting connection
X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9"
Compression fitting ferrule (4)
G10
Sheath material (wetted parts and insert)
T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (8), T13 - 0…1000 °C, T16 - 0…1100 °C regular insert
10/6, 10/8, 12/6, 12/8, 14/6, 14/8, 14/10, 16/10, 20/10
MI insert
6/3, 8/4.5, 10/6, 12/6, 14/6, 16/6, 20/6, 20/8
TF - Teflon®, BR - brass, SS - stainless steel
regular insert
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4401 (1.4404), M15 - 1.4362
MI insert
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M8 - 2.4816, M9 - 1.4401 (1.4404)
G11
Accuracy class
1 - '1' (8), 2 - '2'
G14
Insert tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
#1
Options
X - none, OV - vibration proof (secured screws) (5), OS - spring-loaded insert, OT - thermal isolation (3), OP - electrochemically polished wetted parts
#2
Incorporated devices
X - none, T - in-head transmitter (6), A - local indicator (7)
(1)
'n+m' for TS(O)CS3 and TS(O)CS4! Only for TS(O)CS1 and TS(O)CS2! Only for TS(O)CS! (4) Only for TS(O)CS4! (5) Requires 'OS' option! (6) Only for variant 'OCS'! See transmitter datasheets and order separately! (7) With windowed head only! See indicator datasheets and order separately! (8) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes ANGLED RTD PROBE WITH PROTECTION HEAD
Lx (TSLx)
(FOR IN-HEAD TRANSMITTER)** OLx (TSOLx) Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum, stainless steel, or plastic (see Appendix - Protection heads) DESIGN WITHOUT FLANGE (L)
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
-50...200 °C -50...400 °C -50...600 °C -200...600 °C -0...800 °C
d [mm]
wires
2(3) x Pt (RB,RD,RF,RG)
T9 T1 T11 T2 T4
1 x Cu (RH, RK)
T9
-50...200 °C
10, 12, 14, 16, 20, 22
2, 3, 4*
2 x Cu (RH, RK)
T9
-50...200 °C
12, 14, 16, 20, 22
2x2(3)*
1 x Pt (RB,RD,RF,RG)
10, 12, 14, 16, 20, 22
2, 3, 4*
12, 14, 16, 20, 22
2x2(3)* 3x2*
Protection head: B, MA, MB, G, N, Dx, Ex, EX (see Appendix - Protection heads) Process connection: - welded flange - adjustable flange - no mounting appliances Insertion length: n = 200…1500 mm
DESIGN WITH WELDED FLANGE (L1)
Extension length: m = 100…1000 mm Holding tube: - m1 = 100…1000 mm - OD 20(22) mm - tube/elbow material 1.4301 or 1.4541 Tip shape: standard, narrowed, pitted (see Appendix - Tip shapes) Process pressure: Probe design Max. pressure *
L, L1
L3
25 bar
0 bar
Sheath material: 1.4301(M1), 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362 (M15) Wire material: Cu, Ni, or Ag
DESIGN WITH ADJUSTABLE FLANGE (L3)
* Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance)
temperature probes
Ordering code
TS (1,3) - G0.G1G2.G3.G4.G6.G7'.G7".G9.G10.G11.G12.G13.G14 - #1.#2
Code Feature or option
Code values
Base model variant
L - standard (w/ terminal block), OL - prepared for in-head transmitter (w/o terminal block)
G0
Protection head
B - type "B", MA - type "MA", MB - type "MB", G - IP65, type "G", N - type "N", D - type "D", DW - windowed, type "DW", DH - w/ high cap, type "DH", DHW - windowed, type "DHW", E - IP65, type "E", ES - stainless-steel, type "ES", EG - IP68 ATEX-approved, type "EG", EGS - IP66 ATEX-approved, type "EGS", EGW - windowed ATEX-approved, type "EGW", EX - explosion-proof instrument housing (specify!)
G1
Number of RTD sensors
1, 2, or 3 (6)
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100
G3
Temperature range
T1 - -50…400 °C, T2 - -200…600 °C (Ni or Ag wires only!), T4 - 0…800 °C (Ag wires only!), T9 - -50…200 °C, T11 - -50…600 °C (Ni or Ag wires only!)
G4
Diameter 'd' [mm]
10, 12, 14, 16, 20, 22
G6
Probe length 'n' [mm] (1)
200…1500
G7'
Probe length 'm' [mm] (2)
100…1000
G7"
Probe length 'm1' [mm]
100…1000
G9
Mounting connection
X - no mounting appliances, F - flange (specify!), Z - other connection (specify!)
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404, M15 - 1.4362
G11
Accuracy class (3)
A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (6)
(3)
G13
Wire material
CU - copper, NI - nickel, AG - silver
G14
Tip shape
X - standard closed, N - narrowed, P - pitted (4)
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled, secured screws), OP - electrochemically polished sheath surface
#2
Local indicator
X - none, A - local indicator mounted (5)
(1)
'n+m' for TS(O)L3! Only for TS(O)L1! Only for Pt sensors! (4) Only for non-explosion-proof RTDs! (5) With windowed head only! See indicator datasheets and order separately! (6) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes ANGLED T/C PROBE WITH PROTECTION HEAD
Lx (TSLx)
(FOR IN-HEAD TRANSMITTER)** OLx (TSOLx) Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum, stainless steel, or plastic (see Appendix - Protection heads)
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
d [mm]
wires
Regular Thermocouple Design
DESIGN WITHOUT FLANGE (L)
T4
0...800 °C
10, 12, 14, 16, 20, 22
T3 T16 T6*
0...850 °C 0...1100 °C 0...1150 °C
10, 12, 14, 16, 20, 22
2xE
T3 T13
0...850 °C 0...1000 °C
10, 12, 14, 16, 20, 22
1xS 1xR
T16 T6*
0...1100 °C 0...1150 °C
10, 12, 14, 16, 20, 22
2
2xS 2xR
T16 T6*
0...1100 °C 0...1150 °C
10, 12, 14, 16, 20, 22
2x2
1xJ
T4
0...800 °C
10
2
1xK 1 x N; 1 x E
T3 T16
0...850 °C 0...1100 °C
10
2
2xK
T3 T16
0...850 °C 0...1100 °C
10
2x2
1 x J; 1 x L 2 x J; 2 x L 1xK 2xK 1xE
2 2x2 2 2x2 2 2x2
MI Thermocouple Design
DESIGN WITH WELDED FLANGE (L1)
Protection head: B, MA, MB, G, N, Dx, Ex, EX (see Appendix - Protection heads) Process connection: - welded flange - adjustable flange - no mounting appliances Insertion length: n = 200…1500 mm Extension length: m = 100…1000 mm Holding tube: - m1 = 100…1000 mm - OD 20(22) mm - material 1.4301 or 1.4541 Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip shapes) Process pressure: Probe design Max. pressure *
L, L1
L3
25 bar
0 bar
Sheath material: 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362 (M15) MI sheath material: 1.4541(M2), 1.4571(M3), 1.4876(M7), 2.4816(M8) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)
* Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
DESIGN WITH ADJUSTABLE FLANGE (L3)
temperature probes
Ordering code
TS (1,3) - G0.G1G2.G3.G4.G6.G7'.G7".G9.G10.G11.G14 - #1.#2
Code Feature or option
Code values
Base model variant
L - standard (w/ terminal block), OL - prepared for in-head transmitter (w/o terminal block)
G0
Protection head
B - type "B", MA - type "MA", MB - type "MB", G - IP65, type "G", N - type "N", D - type "D", DW - windowed, type "DW", DH - w/ high cap, type "DH", DHW - windowed, type "DHW", E - IP65, type "E", ES - stainless-steel, type "ES", EG - IP68 ATEX-approved, type "EG", EGS - IP66 ATEX-approved, type "EGS", EGW - windowed ATEX-approved, type "EGW", EX - explosion-proof instrument housing (specify!)
G1
Number of thermocouples
1 or 2
G2
Thermocouple
J - type "J", K - type "K", N - type "N", E - type "E", L - type "L", S - type "S", R - type "R"
G3
Temperature range
T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (5), T13 - 0…1000 °C, T16 - 0…1100 °C
G4
Diameter 'd' [mm]
G6
Probe length 'n' [mm] (1)
200…1500
G7'
Probe length 'm' [mm] (2)
100…1000
G7"
Probe length 'm1' [mm]
100…1000
G9
Mounting connection
X - no mounting appliances, F - flange (specify!), Z - other connection (specify!)
G10
Sheath material
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762, M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4404, M15 - 1.4362
G11
Accuracy class
1 - '1' (5), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction (3), O - open-tube design (3)
#1
Options
X - none, OV - vibration proof (spring-type terminals (5), secured screws), OP - electrochemically polished sheath surface
#2
Local indicator
X - none, A - local indicator mounted (4)
regular T/C MI T/C
regular T/C MI T/C
10, 12, 14, 16, 20, 22 10
M2 - 1.4541, M3 - 1.4571, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600)
(1)
'n+m' for TS(O)L3! Only for TS(O)L1! Only for non-explosion-proof thermocouples! (4) With windowed head only! See indicator datasheets and order separately! (5) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes RTD PROBE WITH PROTECTION HEAD AND OPEN REPLACEABLE INSERT FOR THERMOWELL OR PROTECTION TUBE
DSx (TSDSx)
(FOR IN-HEAD TRANSMITTER)** ODSx (TSODSx) Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum, stainless steel, or plastic (see Appendix - Protection heads) DESIGN WITHOUT EXTENSION (DS)
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
-50...200 °C -50...400 °C -50...600 °C -200...600 °C -0...800 °C
2 x Pt (RB,RD,RF,RG)
T9 T1 T11 T2 T4
1 x Cu (RH, RK)
T9
-50...200 °C
2 x Cu (RH, RK)
T9
-50...200 °C
1 x Pt (RB,RD,RF,RG)
D [mm]
d [mm]
wires
8, 10 10, 12 12, 14
5 6 8
2, 3* 2, 3, 4* 2, 3, 4
10, 12 12, 14 10, 12 12, 14 10, 12 12, 14
6 8 6 8 6 8
2x2* 2x2(3)* 2, 3, 4* 2, 3, 4 2x2* 2x2(3)*
Protection head: B, MA, MB, G, N, Dx, Ex, EX (see Appendix - Protection heads)
EXTENDED DESIGN WITH WELDED CONNECTION (DS1)
Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded flange Thermal isolation between nipple and metal head: (for TS(O)DS only) Protection head
EXTENDED DESIGN WITH MOVABLE CONNECTION (DS2)
Length 'n' up to 50 mm
Maximum temperature
B
up to 100 mm
200 °C
POM
other
up to 150 mm
400 °C
Teflon®
MA, MB
Insulation material
Insertion length (must fit thermowell / protection tube length 'L'!): n = 50…2000 mm Extension length: m = 50…1000 mm (w/o spring-loaded adapter) m = m1...1000 mm (w/ spring-loaded adapter) Tip shape: standard, narrowed, pitted (see Appendix - Tip shapes) Process pressure: - with metal thermowell up to 500 bar (see Accessories - Thermowells) - with ceramic protection tube (see Accessories - Protection tubes) *
DESIGN WITH SLIDING GLAND-TYPE CONNECTION (DS4)
Sheath material: 1.4301(M1) or 1.4541(M2)
Wire material: Cu, Ni, or Ag Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) Spring-loaded adapter: (mounted between probe and protection head)
DESIGN WITH NIPPLE-UNION-NIPPLE CONNECTION (DS5)
m1
20...25
* Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
m1 = 60…100 mm
COMECO reserves the right of changing specifications without prior notice!
Insert sheath material: 1.4301(M1), 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362 (M15)
temperature probes
Ordering code
TS (1,2,4,5) - G0.G1G2.G3.G4.G6.G7.G9'9".G10.G11.G12.G13.G14 - #1.#2
Code Feature or option
Code values
Base model variant
DS - standard (w/ terminal block), ODS - prepared for in-head transmitter (w/o terminal block)
G0
Protection head
B - type "B", MA - type "MA", MB - type "MB", G - IP65, type "G", N - type "N", D - type "D", DW - windowed, type "DW", DH - w/ high cap, type "DH", DHW - windowed, type "DHW", E - IP65, type "E", ES - stainless-steel, type "ES", EG - IP68 ATEX-approved, type "EG", EGS - IP66 ATEX-approved, type "EGS", EGW - windowed ATEX-approved, type "EGW", EX - explosion-proof instrument housing (specify!)
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100
G3
Temperature range
T1 - -50…400 °C, T2 - -200…600 °C (Ni or Ag wires only!), T4 - 0…800 °C (Ag wires only!), T9 - -50…200 °C, T11 - -50…600 °C (Ni or Ag wires only!)
G4
Diameters 'D/d' [mm] (1)
8/5, 10/5, 10/6, 12/6, 14/6, 14/8, 20/6, 21/6, 20/8, 21/8
G6
Probe length 'n' [mm]
50…2000
G7
Probe length 'm' [mm] (2)
50…1000 (m1…1000 with 'OA' option)
G9'
Mounting connection
X - no mounting appliances, Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9"
Compression fitting ferrule (3)
TF - Teflon®, BR - brass, SS - stainless steel
G10
Insert sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404, M15 - 1.4362
(4)
G11
Accuracy class
G12
Number of wires
A - 'A', B - 'B', C - '2xB' 2, 3, 4 (10)
G13
Wire material (4)
CU - copper, NI - nickel, AG - silver
G14
Tip shape
X - standard closed, N - narrowed, P - pitted (5)
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled insert, secured screws) (6), OS - spring-loaded insert, OT - thermal isolation (7), OA - spring-loaded adapter (8), OP - electrochemically polished sheath surface
#2
Local indicator
X - none, A - local indicator mounted (9)
(1)
Only 'd' for TS(O)DS! Omit for TS(O)DS without 'OA' option! (3) Only for TS(O)DS4! (4) Only for Pt sensors! (5) Only for non-explosion-proof RTDs! (6) Requires 'OS' option! (7) Only for TS(O)DS! (8) Only for TS(O)DS, TS(O)DS1, and TS(O)DS5! Insert is not replaceable! (9) With windowed head only! See indicator datasheets and order separately! (10) Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes T/C PROBE WITH PROTECTION HEAD AND OPEN REPLACEABLE INSERT FOR THERMOWELL OR PROTECTION TUBE
DSx (TSDSx)
(FOR IN-HEAD TRANSMITTER)*** ODSx (TSODSx) Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum, stainless steel, or plastic (see Appendix - Protection heads)
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
D [mm]
d [mm]
wires
MI Thermocouple Insert Design
DESIGN WITHOUT EXTENSION (DS)
1xJ
2
T4
0...800 °C
8,10,12,14
3, 4.5, 6, 8
T3 T16 T6* T6*
0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C
8,10,12,14
3, 4.5, 6, 8
1 x S, 1 x R
T16 T6*
0...1100 °C 0...1150 °C
8,10,12,14
3, 4.5, 6
2
2 x S, 2 x R
T16 T6* T14** T15**
0...1100 °C 0...1150 °C 0...1600 °C 0...1700 °C
8,10,12,14
3, 4.5, 6
2x2
2xJ 1xK 1 x N, 1 x E 2xK 2 x N, 2 x E
EXTENDED DESIGN WITH WELDED CONNECTION (DS1)
2x2 2 2x2
Protection head: B, MA, MB, G, N, Dx, Ex, EX (see Appendix - Protection heads) Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded flange Thermal isolation between nipple and metal head: (for TS(O)DS only) Protection head
EXTENDED DESIGN WITH MOVABLE CONNECTION (DS2)
Length 'n'
MA, MB
up to 50 mm
Maximum temperature
B other
up to 100 mm up to 150 mm
200 °C 400 °C
Insulation material POM Teflon®
Insertion length (must fit thermowell / protection tube length 'L'!): n = 50…2000 mm Extension length: m = 50…1000 mm (w/o spring-loaded adapter) m = m1...1000 mm (w/ spring-loaded adapter) Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip shapes) Process pressure: - with metal thermowell up to 500 bar (see Accessories - Thermowells) - with ceramic protection tube (see Accessories - Protection tubes) * Sheath material: 1.4301(M1) or 1.4541(M2) MI-insert sheath material: 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4876(M7), 2.4816(M8) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)
DESIGN WITH NIPPLE-UNION-NIPPLE CONNECTION (DS5)
Spring-loaded adapter: (mounted between probe and protection head)
m1
20...25
* Please contact COMECO! ** With ceramic protection tubes only! *** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
m1 = 60…100 mm
COMECO reserves the right of changing specifications without prior notice!
DESIGN WITH SLIDING GLAND-TYPE CONNECTION (DS4)
temperature probes
Ordering code
TS (1,2,4,5) - G0.G1G2.G3.G4.G6.G7.G9'9".G10.G11.G14 - #1.#2
Code Feature or option
G0
Code values
Base model variant
DS - standard (w/ terminal block), ODS - prepared for in-head transmitter (w/o terminal block)
Protection head
B - type "B", MA - type "MA", MB - type "MB", G - IP65, type "G", N - type "N", D - type "D", DW - windowed, type "DW", DH - w/ high cap, type "DH", DHW - windowed, type "DHW", E - IP65, type "E", ES - stainless-steel, type "ES", EG - IP68 ATEX-approved, type "EG", EGS - IP66 ATEX-approved, type "EGS", EGW - windowed ATEX-approved, type "EGW", EX - explosion-proof instrument housing (specify!)
G1
Number of thermocouples
1 or 2
G2
Thermocouple
J - type "J", K - type "K", N - type "N", E - type "E", L - type "L", S - type "S", R - type "R"
G3
Temperature range
T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (9), T13 - 0…1000 °C, T14 - 0…1600 °C, T15 - 0…1700 °C, T16 - 0…1100 °C
G4
Diameters 'D/d' [mm] (1)
8/3, 10/3, 8/4.5, 10/4.5, 12/6, 14/6, 20/6 (2), 21/6, 20/8 (2), 21/8
G6
Probe length 'n' [mm]
50…2000
G7
Probe length 'm' [mm] (3)
50…1000 (m1…1000 with 'OA' option)
G9'
Mounting connection
X - no mounting appliances, Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9"
Compression fitting ferrule (4)
TF - Teflon®, BR - brass, SS - stainless steel
G10
Insert sheath material
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762, M5 - 1.4841, M6 - 1.4845, M8 - 2.4816, M9 - 1.4404
G11
Accuracy class
1 - '1' (9), 2 - '2'
G14
Insert tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
#1
Options
X - none, OV - vibration proof (secured screws) (5), OS - spring-loaded insert, OT - thermal isolation (6), OA - spring-loaded adapter (7), OP - electrochemically polished sheath surface
#2
Local indicator
X - none, A - local indicator mounted (8)
(1)
Only 'd' for TS(O)DS! Not available with G10='M6' Omit for TS(O)DS without 'OA' option! (4) Only for TS(O)DS4! (5) Requires 'OS' option! (6) Only for TS(O)DS! (7) Only for TS(O)DS, TS(O)DS1, and TS(O)DS5! Insert is not replaceable! (8) With windowed head only! See indicator datasheets and order separately! (9) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
(MI) T/C PROBE WITH PROTECTION HEAD AND CERAMIC PROTECTION TUBE
TSZx
- FOR IN-HEAD TRANSMITTER ** TSOZx Holding tube - stainless steel 1.4301 or 1.4404 Protection tube - ceramic (see Accessories - Protection tubes) Head - aluminum, stainless steel, iron, or plastic (see Appendix - Protection heads)
WIRE [mm] SENSITIVE TEMPERATURE TUBE / ELEMENT RANGE MATERIAL MI [mm]
DIMENSIONS d [mm]
D [mm]
Regular Design T13
STRAIGHT DESIGN (TS(O)Z)
T6
0...1000 °C 0...1200 °C
1.0
C1(2),C6
10
16
C1(2)
15
22
C6, C7
16, 19
22, 24
C5
17
24
C1(2)
24
32
C4, C7
22, 28
30, 36
C5
23
30
C6
25, 32
32, 40
C1(2)
10,15,24
16,22,32
C4
22
30
C5
17, 23
24, 30
1.5
1 x K; 1 x N 2 X K, 2 X N T6
T21
0...1200 °C
0...1300 °C
3.0
0.35
C6 10,16,19,25 16,22,24,32 1 x S; 1 x R 2 X S, 2 X R T5
ANGLED DESIGN (TS(O)ZL)
0...1500 °C
0.35, 0.5
T14
0...1600 °C
0.5
1 x B; 2 x B
T14
0...1600 °C
0.35
1 x B; 2 x B
T15
0...1700 °C
0.5
T16
0...1100 °C
C7*
16,22,28
22,30,36
C1(2)
10,15,24
16,22,32
C5
17, 23
24, 30
C6 10,16,19,25 16,22,24,32 C2
10,15,24
16,22,32
C6 10,16,19,25 16,22,24,32 C2
10,15,24
16,22,32
C6 10,16,19,25 16,22,24,32 C3
10,15,24
16,22,32
C6* 10,16,19,25 16,22,24,32
1 x K; 1 x N 2 X K, 2 X N
T16 0...1100 °C (Inconel 600) T6 0...1200 °C (Nicrobell®)
1 x S, 2 x S
n = 200…nmax nmax can be defined from the table below: n [mm] ≤ 400 ≤ 800 ≤ 1800
d≤ single L - 50 L - 70 L - 100
16 double L - 70 L - 100 L - 100
d ≤ 32 any L - 100 L - 100 L - 100
where 'L' is the length of the protection tube (see Accessories - Protection Tubes) Holding tube: - m1 = 100…1000 mm - OD 20(22) mm - tube/elbow material 1.4301 or 1.4541
T16 0...1100 °C (Inconel 600)
10
16
C1
15
22
C6, C7
16, 19
22, 24
C5
17, 23
24, 30
3, 4.5, 6, 8, 10
C1
24
32
C4, C7
22, 28
30, 36
C6
25, 32
32, 40
3, 4.5
C1, C6
10
16
C1
15
22
C6, C7
16, 19
22, 24
C5
17, 23
24, 30
3, 4.5, 6, 8
3, 4.5, 6
Protection head: B, MA, MB, G, N, Cx, Dx, Ex (see Appendix - Protection Heads) Process connection: - welded or adjustable flange - w/o mounting appliances Extension length: m = 100…1000 mm Extension tube material: 1.4301(M1), 1.4541(M2), 1.4404(M9), 1.4571(M3) MI sheath material: 2.4816(M8), Nicrobell® (M10) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) * Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
C1, C6
3, 4.5
COMECO reserves the right of changing specifications without prior notice!
MI Design
temperature probes
Ordering code
TS (L) - (MI -) G0.G1G2.G3.G4.G5.G6.G7'.G7".G9.G10'.G10".G11 - #1
Code Feature or option
Code values
Base model variant
Z - standard (w/ terminal block), OZ - prepared for in-head transmitter (w/o terminal block)
Protection head
B - type "B", CC - type "CC", CS - type "CS", D - type "D", DH - type "DH", DHW - type "DHW", DW - type "DW", E - type "E", EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", ES - type "ES", G - type "G", MA - type "MA", MB - type "MB", N - type "N"
G1
Number of thermocouples
1 or 2
G2
Thermocouple Check wire-to-sheath compatibility in the specification table!
G0
regular design MI design
B - type "B", K - type "K", N - type "N", R - type "R", S - type "S" K - type "K", N - type "N", S - type "S" T5 - 0…1500 °C, T6 - 0…1200 °C, T13 - 0…1000 °C, T14 - 0…1600 °C, T15 - 0…1700 °C, T16 - 0…1100 °C, T21 - 0…1300 °C
G3
Temperature range
G4
Diameter 'd' [mm]
G5
Diameter 'D' [mm]
16, 22, 24, 30, 32, 36, 40
G6
Probe length 'n' [mm]
200…1800 (see table overleaf)
G7'
Probe length 'm' [mm]
100…1000
G7"
Probe length 'm1' [mm]
100…1000
G9
Mounting connection
X - no mounting appliances, F - flange (specify!), Z - other connection (specify!)
G10'
Protection tube material
C1 - ceramic Pythagoras 610, C2 - ceramic Oxal 710, C3 - ceramic Alsint 799, C4 - metal-ceramic Ucar®, C5 - silicon carbide, C6 - Hexoloy®, C7 - Syalon
G10"
Extension tube material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
G11
Accuracy class
1 - '1' (3), 2 - '2'
#1
Incorporated devices
X - none, T - in-head transmitter (1), A - local indicator (2)
single tube
10, 15, 16, 17, 19, 22, 23, 24, 25, 28, 32 (see table overleaf)
double tube
24/10, 24/15, etc. (see 'Accessories - Protection Tubes YA' for available combinations!)
(1)
Only for variant 'OZ'! See transmitter datasheets and order separately! With windowed head only! See indicator datasheets and order separately! (3) Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes (MI) T/C PROBE WITH PROTECTION HEAD AND CERAMIC PROTECTION TUBE
TSZx
- FOR IN-HEAD TRANSMITTER ** TSOZx Holding tube - stainless steel 1.4301 or 1.4404 Protection tube - ceramic (see Accessories - Protection tubes) Head - aluminum, stainless steel, iron, or plastic (see Appendix - Protection heads)
WIRE [mm] SENSITIVE TEMPERATURE TUBE / ELEMENT RANGE MATERIAL MI [mm]
DIMENSIONS d [mm]
D [mm]
Regular Design T13
STRAIGHT DESIGN (TS(O)Z)
T6
0...1000 °C 0...1200 °C
1.0
C1(2),C6
10
16
C1(2)
15
22
C6, C7
16, 19
22, 24
C5
17
24
C1(2)
24
32
C4, C7
22, 28
30, 36
C5
23
30
C6
25, 32
32, 40
C1(2)
10,15,24
16,22,32
C4
22
30
C5
17, 23
24, 30
1.5
1 x K; 1 x N 2 X K, 2 X N T6
T21
0...1200 °C
0...1300 °C
3.0
0.35
C6 10,16,19,25 16,22,24,32 1 x S; 1 x R 2 X S, 2 X R T5
ANGLED DESIGN (TS(O)ZL)
0...1500 °C
0.35, 0.5
T14
0...1600 °C
0.5
1 x B; 2 x B
T14
0...1600 °C
0.35
1 x B; 2 x B
T15
0...1700 °C
0.5
T16
0...1100 °C
C7*
16,22,28
22,30,36
C1(2)
10,15,24
16,22,32
C5
17, 23
24, 30
C6 10,16,19,25 16,22,24,32 C2
10,15,24
16,22,32
C6 10,16,19,25 16,22,24,32 C2
10,15,24
16,22,32
C6 10,16,19,25 16,22,24,32 C3
10,15,24
16,22,32
C6* 10,16,19,25 16,22,24,32
1 x K; 1 x N 2 X K, 2 X N
T16 0...1100 °C (Inconel 600) T6 0...1200 °C (Nicrobell®)
1 x S, 2 x S
n = 200…nmax nmax can be defined from the table below: n [mm] ≤ 400 ≤ 800 ≤ 1800
d≤ single L - 50 L - 70 L - 100
16 double L - 70 L - 100 L - 100
d ≤ 32 any L - 100 L - 100 L - 100
where 'L' is the length of the protection tube (see Accessories - Protection Tubes) Holding tube: - m1 = 100…1000 mm - OD 20(22) mm - tube/elbow material 1.4301 or 1.4541
T16 0...1100 °C (Inconel 600)
10
16
C1
15
22
C6, C7
16, 19
22, 24
C5
17, 23
24, 30
3, 4.5, 6, 8, 10
C1
24
32
C4, C7
22, 28
30, 36
C6
25, 32
32, 40
3, 4.5
C1, C6
10
16
C1
15
22
C6, C7
16, 19
22, 24
C5
17, 23
24, 30
3, 4.5, 6, 8
3, 4.5, 6
Protection head: B, MA, MB, G, N, Cx, Dx, Ex (see Appendix - Protection Heads) Process connection: - welded or adjustable flange - w/o mounting appliances Extension length: m = 100…1000 mm Extension tube material: 1.4301(M1), 1.4541(M2), 1.4404(M9), 1.4571(M3) MI sheath material: 2.4816(M8), Nicrobell® (M10) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) * Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
C1, C6
3, 4.5
COMECO reserves the right of changing specifications without prior notice!
MI Design
temperature probes
Ordering code
TS (L) - (MI -) G0.G1G2.G3.G4.G5.G6.G7'.G7".G9.G10'.G10".G11 - #1
Code Feature or option
Code values
Base model variant
Z - standard (w/ terminal block), OZ - prepared for in-head transmitter (w/o terminal block)
Protection head
B - type "B", CC - type "CC", CS - type "CS", D - type "D", DH - type "DH", DHW - type "DHW", DW - type "DW", E - type "E", EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", ES - type "ES", G - type "G", MA - type "MA", MB - type "MB", N - type "N"
G1
Number of thermocouples
1 or 2
G2
Thermocouple Check wire-to-sheath compatibility in the specification table!
G0
regular design MI design
B - type "B", K - type "K", N - type "N", R - type "R", S - type "S" K - type "K", N - type "N", S - type "S" T5 - 0…1500 °C, T6 - 0…1200 °C, T13 - 0…1000 °C, T14 - 0…1600 °C, T15 - 0…1700 °C, T16 - 0…1100 °C, T21 - 0…1300 °C
G3
Temperature range
G4
Diameter 'd' [mm]
G5
Diameter 'D' [mm]
16, 22, 24, 30, 32, 36, 40
G6
Probe length 'n' [mm]
200…1800 (see table overleaf)
G7'
Probe length 'm' [mm]
100…1000
G7"
Probe length 'm1' [mm]
100…1000
G9
Mounting connection
X - no mounting appliances, F - flange (specify!), Z - other connection (specify!)
G10'
Protection tube material
C1 - ceramic Pythagoras 610, C2 - ceramic Oxal 710, C3 - ceramic Alsint 799, C4 - metal-ceramic Ucar®, C5 - silicon carbide, C6 - Hexoloy®, C7 - Syalon
G10"
Extension tube material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
G11
Accuracy class
1 - '1' (3), 2 - '2'
#1
Incorporated devices
X - none, T - in-head transmitter (1), A - local indicator (2)
single tube
10, 15, 16, 17, 19, 22, 23, 24, 25, 28, 32 (see table overleaf)
double tube
24/10, 24/15, etc. (see 'Accessories - Protection Tubes YA' for available combinations!)
(1)
Only for variant 'OZ'! See transmitter datasheets and order separately! With windowed head only! See indicator datasheets and order separately! (3) Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
ANGLED RTD PROBE WITH PROTECTION HEAD FOR PROTECTION TUBE ASSEMBLY
LDx (TSLDx)
(FOR IN-HEAD TRANSMITTER)** OLDx (TSOLDx) Holding tube - stainless steel 1.4301 or 1.4404 Protection tube - metal (see Accessories - Protection tubes) Head - aluminum, stainless steel, or plastic (see Appendix - Protection heads)
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
2 x Pt (RB,RD,RF,RG)
T9 T1 T11 T2 T4
1 x Cu (RH, RK)
T9
1 x Pt (RB,RD,RF,RG)
2 x Cu (RH, RK)
T9
-50...200 °C -50...400 °C -50...600 °C -200...600 °C -0...800 °C
d [mm]
wires
6
2, 3, 4*
8, 10, or bare
2, 3, 4
6*, 8, 10, or bare
2x2
6 or bare
2, 3
8, 10, or bare
2, 3, 4*
8, 10, or bare
2x2
-50...200 °C
-50...200 °C
Protection head: B, MA, MB, G, N, Dx, Ex, EX (see Appendix - Protection heads) Process connection (must fit the YA connection 'G'): G1/2"(Q4), G3/4"(Q6), male or female (see Accessories - Protection tubes) Insertion length (must fit the YA length 'L'): n = 100…1000 mm Holding tube: - m1 = 100…1000 mm - OD 20(22) mm - tube/elbow material 1.4301 or 1.4541 Tip shape: standard, narrowed, pitted (see Appendix - Tip shapes) Process pressure: YA protection tube process pressure (see Accessories - Protection tubes) Sheath material: 1.4301(M1), 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362 (M15), or bare sensor Wire material: Cu, Ni, or Ag Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance)
d [mm]
M1, M3, M4, M6, M6S, M8, M9, M11, M13, M14
6, 8, 10
M12
6, 8
M20
6
* Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Protection Tube Material
20...25
60...100
Spring-loaded adapter: (mounted between protection tube and elbow)
temperature probes
Ordering code
TS - G0.G1G2.G3.G4.G6.G7.G9.G10.G11.G12.G13.G14 - #1.#2
Code Feature or option
Code values
Base model variant
LD - standard (w/ terminal block), OLD - prepared for in-head transmitter (w/o terminal block)
G0
Protection head
B - type "B", MA - type "MA", MB - type "MB", G - IP65, type "G", N - type "N", D - type "D", DW - windowed, type "DW", DH - w/ high cap, type "DH", DHW - windowed, type "DHW", E - IP65, type "E", ES - stainless-steel, type "ES", EG - IP68 ATEX-approved, type "EG", EGS - IP66 ATEX-approved, type "EGS", EGW - windowed ATEX-approved, type "EGW", EX - explosion-proof instrument housing (specify!)
G1
Number of RTD sensors
1, 2, or 3 (5)
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100
G3
Temperature range
T1 - -50…400 °C, T2 - -200…600 °C (Ni or Ag wires only!), T4 - 0…800 °C (Ag wires only!), T9 - -50…200 °C, T11 - -50…600 °C (Ni or Ag wires only!)
G4
Diameter 'd' [mm] (must fit the protection tube ID)
X (bare sensor), 6, 8, 10
G6
Probe length 'n' [mm]
100…1000
G7
Probe length 'm1' [mm]
100…1000
G9
Mounting connection (must fit the protection tube thread)
Q4 - G1/2", Q6 - G3/4", U4 - G1/2-F", U6 - G3/4-F"
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404, M15 - 1.4362
G11
Accuracy class (1)
A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (5)
(1)
G13
Wire material
G14
Tip shape
CU - copper, NI - nickel, AG - silver X - standard closed, N - narrowed, P - pitted (2)
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled, secured screws), OA - spring-loaded adapter (3), OP - electrochemically polished sheath surface
#2
Local indicator
X - none, A - local indicator mounted (4)
(1)
Only for Pt sensors! Only for non-explosion-proof RTDs! Not available for bare sensor! (4) With windowed head only! See indicator datasheets and order separately! (5) Contact COMECO! (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes ANGLED T/C PROBE WITH PROTECTION HEAD FOR PROTECTION TUBE ASSEMBLY
LDx (TSLDx)
(FOR IN-HEAD TRANSMITTER)** OLDx (TSOLDx) Holding tube - stainless steel 1.4301 or 1.4404 Protection tube - metal (see Accessories - Protection tubes) Head - aluminum, stainless steel, or plastic (see Appendix - Protection heads)
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
wire ø [mm]
d [mm]
wires
Regular Thermocouple Design 8
1
10
1.5
bare
1, 1.5, 3
1 x J; 2 x J 0...800 °C
T4 1 x L; 2 x L
1 x K; 2 x K
1 x E; 2 x E
1 x S; 2 x S 1 x R; 2 x R
T3 T16 T6*
0...850 °C 0...1100 °C 0...1150 °C
T3 T13
0...850 °C 0...1000 °C
T16 T6* T21
0...1100 °C 0...1150 °C 0...1300 °C
10
1.5
bare
1.2, 3.2
8
1
10
1.5
bare
1, 1.5, 3
8
1
10
1.5
bare
1, 1.5, 3
8, 10, or bare
0.35, 0.5
2; 2x2
2; 2x2
2; 2x2
2; 2x2
2; 2x2
MI Thermocouple Design 1xJ 2xJ 1xK 1 x N; 1 x E 2xK 2 x N, 2 x E
T4
0...800 °C
3, 4.5, 6, 8
T3 T16 T6* T6*
0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C
3, 4.5, 6, 8, 10
2 2x2 2 2x2
Protection head: B, MA, MB, G, N, Dx, Ex, EX (see Appendix - Protection heads) Process connection (must fit the YA connection 'G'): G1/2"(Q4), G3/4"(Q6), male or female (see Accessories - Protection tubes) Insertion length (must fit the YA length 'L'): n = 100…1000 mm Holding tube: - m1 = 100…1000 mm - OD 20(22) mm - tube/elbow material 1.4301 or 1.4541 Tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip shapes)
Protection Tube Material
Sheathed T/C max. d [mm]
Bare T/C max. ø [mm]
M11, M14
10
4 x ø3
M3, M4, M6, M6S, M8, M9
10
2 x ø3
Sheath material: 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362 (M15) MI sheath material: 1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762(M4), 1.4841(M5), 1.4876(M7), 2.4816(M8), Nicrobell® (M10) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance)
* Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
20...25
60...100
Spring-loaded adapter: (mounted between protection tube and elbow)
COMECO reserves the right of changing specifications without prior notice!
Process pressure: YA protection tube process pressure (see Accessories - Protection tubes)
temperature probes
Ordering code
TS - G0.G1G2.G3.G4.G6.G7.G9.G10.G11.G14 - #1.#2
Code Feature or option
Code values
Base model variant
LD - standard (w/ terminal block), OLD - prepared for in-head transmitter (w/o terminal block)
G0
Protection head
B - type "B", MA - type "MA", MB - type "MB", G - IP65, type "G", N - type "N", D - type "D", DW - windowed, type "DW", DH - w/ high cap, type "DH", DHW - windowed, type "DHW", E - IP65, type "E", ES - stainless-steel, type "ES", EG - IP68 ATEX-approved, type "EG", EGS - IP66 ATEX-approved, type "EGS", EGW - windowed ATEX-approved, type "EGW", EX - explosion-proof instrument housing (specify!)
G1
Number of thermocouples
1 or 2
G2
Thermocouple
J - type "J", K - type "K", N - type "N", E - type "E", L - type "L", S - type "S", R - type "R"
G3
Temperature range
T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (4), T13 - 0…1000 °C, T16 - 0…1100 °C, T21 - 0…1300 °C
G4
Diameter 'd' [mm] (must fit the protection tube ID)
G6
Probe length 'n' [mm]
100…1000
G7
Probe length 'm1' [mm]
100…1000
G9
Mounting connection (must fit the protection tube thread)
Q4 - G1/2", Q6 - G3/4", U4 - G1/2-F", U6 - G3/4-F"
G10
Sheath material
regular T/C
X (bare thermocouple), 8, 10
MI T/C
3, 4.5, 6, 8, 10
regular T/C
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762, M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4404, M15 - 1.4362
MI T/C
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876 (Incolloy 800), M8 - 2.4816 (Inconel 600), M9 - 1.4404, M10 - Nicrobell®
G11
Accuracy class
1 - '1' (4), 2 - '2'
G14
Tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction (1), O - open-tube design (1)
#1
Options
X - none, OV - vibration proof (spring-type terminals (4), secured screws), OA - spring-loaded adapter (2), OP - electrochemically polished sheath surface
#2
Local indicator
X - none, A - local indicator mounted (3)
(1)
Only for non explosion-proof thermocouples! Not available for bare thermocouple! (3) With windowed head only! See indicator datasheets and order separately! (4) Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
(MI) RTD PROBE WITH DETACHABLE CONNECTOR
TSKx
Sheath - stainless steel (see Appendix - Sheath materials) Connector - IP65/68 (see Appendix - Sensor connectors)
SENSITIVE ELEMENT
DIMENSIONS
TEMPERATURE RANGE
n [mm]
d [mm]
wires
Regular Design
DESIGN WITHOUT EXTENSION (TSK) 1 x Pt (RB,RD,RF,RG) 2 x Pt (RB,RD,RF,RG) 3 x Pt * (RB,RD,RF,RG)
T9 T1 T24 T11 T2 T4 T22
1 x Cu (RH, RK) -50...200 °C
T9 2 x Cu (RH, RK)
-50...100 °C
T12
2 x PTC (RP, RQ)
2, 3*
5
2, 3
50…1500
6
2, 3, 4*
50…3000
8, 10, 12, 14
2, 3, 4
50…3000
6*, 8, 10, 12, 14
2x2(3)*
50…3000
8, 10, 12, 14
3x2
50…1500
6
50…3000
8, 10, 12, 14
50…3000
EXTENDED DESIGN WITH WELDED CONNECTION (TSK1) 1 x PTC (RP, RQ)
4
50…500
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C
2, 3, 4*
8, 10
2x2
12, 14
2x2(3)*
50…1500
6
50…3000
8, 10, 12, 14
50…3000
8, 10, 12, 14
2, 3 2x2
MI Design 1 x Pt (RB,RD,RF,RG)
2 x Pt (RB,RD,RF,RG)
EXTENDED DESIGN WITH MOVABLE CONNECTION (TSK2)
T9 T1 T24 T11 T2 T4 T22
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C
3*
2, 3*
4.5
2, 3*
6
2, 3, 4*
8
2, 3, 4
6, 8
2x2, 2x3*
50...50000
50...50000
Detachable wiring connector: C1, C7, C8 (see Appendix - Connectors) Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1
DESIGN WITH ADJUSTABLE CONNECTION (TSK3)
Extension length: m = 0...1500 mm Probe diameter 'd' Ext. length 'm' up to 50 mm 50...150 mm 150...500 mm 500+ mm
3, 4 mm
4.5...6 mm
8 mm
10 mm
10+ mm
8 8 10 14
d 8 10 14
d d 10 14
d d d 14
d d d d
Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes) Process pressure:
DESIGN WITH GLAND-TYPE CONNECTION (TSK4)
Probe design Max. pressure *
TSK, TSK1
TSK2
TSK4
TSK3
25 bar
16 bar
6 bar
0 bar
Sheath material: 1.4301(M1), 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362(M15) Wire material: Cu, Ni, or Ag Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) * Please contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Extension diameter: (for TSK1 and TSK2 only, [mm])
temperature probes
Ordering code
TSK(1,2,3,4) - (MI -) G1G2.G3.G4.G6.G7.G9'9".G10.G11.G12.G13.G14.G15 - #1
Code Feature or option
Code values
G1
Number of RTD sensors (1)
1, 2, or 3 (10)
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP - PTC 1k, RQ - PTC 2k
G3
Temperature range
T1 - -50…400 °C, T2 - -200…600 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C, T22 - -200…200 °C, T24 - -50…500 °C
G4
Diameter 'd' [mm]
G6
Probe length 'n' [mm] (2)
50…50000 (see table overleaf)
G7
Probe length 'm' [mm] (3)
0…1500
G9'
Mounting connection
X - no mounting appliances (4), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9"
Compression fitting ferrule (5)
BR - brass, GR - graphite, SS - stainless steel, TF - Teflon®
G10
Sheath material (wetted parts)
G11
Accuracy class
X - none (6), A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (10)
G13
Wire material (7)
CU - copper (8), NI - nickel, AG - silver (9)
G14
Tip shape
X - standard closed, N - narrowed (9), P - pitted (9)
G15
Wiring connector
C1 - 4-pin connector M12 (IP68), C7 - DIN 43650 4-pin connector (IP65), C8 - DIN 43651 6-pin connector (IP65)
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled) (9), OP - electrochemically polished wetted parts (9)
regular design
4, 5, 6, 8, 10, 12, 14
MI design
3 (10), 4.5, 6, 8
regular design
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404), M15 - 1.4362
MI design
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404)
(1)
The total number of wires must comply with the selected wiring connector! 'n+m' for TSK3 and TSK4! (3) Only for TSK1 and TSK2! (4) Only for TSK! (5) Only for TSK4! (6) For non-Pt sensors (7) Only for Pt sensors! (8) Not applicable to non-MI (regular) RTDs for above 500 °C! (9) Only for non-MI (regular) design! (10) Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes
OUTDOOR RTD PROBE WITH ANCHOR BOLT
TSCA SENSITIVE ELEMENT
Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum (see Appendix - Protection heads)
TEMPERATURE RANGE
DIMENSIONS d [mm]
wires
4
2
5
2, 3*
6
2, 3, 4*
1 x Pt (RB,RD,RF,RG)
T12
-50...100 °C
2 x Pt (RB,RD,RF,RG)
T12
-50...100 °C
6
2x2
1 x Cu (RH, RK)
T12
-50...100 °C
5, 6
2, 3
2 x Cu (RH)
T12
-50...100 °C
6
2x2
1 x PTC (RP, RQ)
T12
-50...100 °C
6
2
Protection head: MA, MB (see Appendix - Protection Heads) Mounting accessories: Zn-plated anchor bolt (ø8) w/ rubber sealed clamp (ø20) Tip shape: standard, narrowed, pitted (see Appendix - Tip Shapes)
Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) n = 40 … 180 mm
Filling: silicone grease (except pitted version) Protection tube: PVC, ø20x2 Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance)
* Please contact COMECO!
TSCA - G0.G1G2.G4.G6.G10.G11.G12.G14
Code Feature or option
Code values
G0
Protection head
MA - type "MA", MB - type "MB"
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP -PTC 1k, RQ - PTC 2k
G4
Diameter 'd' [mm]
4, 5, 6
G6
Anchor bolt length 'n' [mm]
40…180 (step 10 mm)
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
G11
Accuracy class (1)
A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (2)
G14
Tip shape
X - standard closed, N - narrowed, P - pitted
(1) (2)
Only for Pt sensors! Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Ordering code
temperature probes
RTD PROBE FOR MEAT CUTTING MACHINES
TSCC
Sheath - stainless steel (see Appendix - Sheath materials) Head - aluminum or stainless steel (see Appendix - Protection heads)
SENSITIVE ELEMENT
TEMPERATURE RANGE
WIRES
1 x Pt (RB,RD,RF,RG)
T9
-50...200 째C
2, 3, 4
2 x Pt (RB,RD,RF,RG)
T9
-50...200 째C
2x2, 2x3*
1 x Cu (RH, RK)
T9
-50...200 째C
2, 3, 4
2 x Cu (RH)
T9
-50...200 째C
2x2, 2x3*
Protection head: B, MA, MB, D, G, ES (see Appendix - Protection Heads) Sheath material: 1.4301 (M1), 1.4541 (M2), 1.4571 (M3), 1.4404 (M9) Filling: silicone grease Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) * Please contact COMECO!
Ordering code
TSCC - G0.G1G2.G10.G11.G12 - #1
Code Feature or option
Code values
G0
Protection head
B - type "B", MA - type "MA", MB - type "MB", D - type "D", G - type "G", ES - type "ES"
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100
G10
Sheath material (1)
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
G11
Accuracy class
G12
Number of wires
2, 3, 4 (2)
#1
Options
X - none, OP - electrochemically polished sheath surface
(2)
Only for Pt sensors! Contact COMECO!
COMECO reserves the right of changing specifications without prior notice!
(1)
A - 'A', B - 'B', C - '2xB'
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes Outdoor RTD Probe (Transmitter) TS(O)P ♦ ♦ ♦ ♦ ♦ ♦
Low cost Ptx sensitive element 2-wire 4…20 mA output available IP66 protection class Robust aluminum enclosure Ready to use - no adjustments
The outdoor temperature probes TSP and TSOP measure temperature by means of a Ptx sensitive element mounted in a thin stainless steel stem for fast response. The TSOP model, in addition, converts the measured temperature into standard 4...20 mA 2-wire signal. Both models are enclosed in a freely mountable robust aluminum enclosure with IP66 protection class and are equipped with a PG7 cable gland for stable and protected electrical decoupling. Five different temperature measurement ranges from -50 °C and up to 100 °C as well as customer specified ranges are available. Thanks to their simplicity, small size, and affordable price, TSP and TSOP are applicable for various outdoor applications, environment temperature control, climatic temperature measurement, etc.
Technical specifications Input
Power supply
Incorporated RTD Measurement range
Pt100 or Pt1000 (w=1.385) -50...50 °C; 0...50 °C; -20...60 °C; 0...100 °C (1); -50...100 °C (1) minimum span 50 °C (transmitter only)
Range on request
Output Signal type Linearity proportional to Output at sensor burnout Output at sensor shorted
Accuracy Electronic measurement error RTD measurement error Non-linearity Self-heating error Temperature drift (2)
Operating conditions Ambient temperature Ambient humidity EM compatibility
-30...65 °C 5...95 %RH according to EN 61326
Design and materials Stem diameter Stem length Sensor sheath Housing material Wiring Mounting Protection class
4 mm 20...60 mm
5 mm 60...200 mm stainless steel aluminum PG7 metal cable gland free IP66
Not available for TSOP Which is greater
Ordering code
TS(O)P - G2.G3.G6.G11 - #1
Code Feature or option
(3)
(transmitter only) 0.2% from span or 0.2 °C (2) according to accuracy class within measurement error 0.02%/mA at 24 V 0.02% from span for 1 °C
10...32 VDC 1 Vp-p at 50 Hz 750 Ω at 24V/20mA
Code values
G2
Sensor (3)
RD - Pt100, RG - Pt1000
G3
Temperature range
T10 - -20...60 °C, T17 - -50...50 °C, T18 - 0...50 °C, T19 - 0...100 °C (1), T12 - -50...100 °C (1), TZ - other (specify, ΔT ≥ 50 °C)
G6
Stem length 'n' [mm]
20…200 (see table above)
G11
Accuracy class
A - 'A', B - 'B', C - '2xB'
#1
Options
X - none, OP - electrochemically polished sheath surface
Do not code for TSOP
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(1)
4...20 mA, 2-wire measured value 32 mA 0.2 mA
Loop voltage Admissible variations Maximum line load
temperature probes Indoor RTD Probe (Transmitter) TS(O)R ♦ ♦ ♦ ♦ ♦ ♦
Low-cost variant for budget applications Ptx sensitive element 2-wire 4…20 mA output available Easy & Fast connection plug Ready to use - no adjustments DIN-rail accessory available
The indoor temperature probes TSR, TSR1, TSOR, and TSOR1 perform fast temperature measurement by means of a Ptx sensitive element mounted in a copper sheath or inside the housing. The TSOR and TSOR1 variants, in addition, convert the measured temperature into standard 4...20 mA 2-wire signal. All variants are enclosed in a freely mountable small plastic box that may also be mounted on a DIN rail when an optional mounting clamp is installed. TSR and TSOR are also equipped with a 3-pin plug-in terminal that allow fast and easy electrical decoupling. Five different temperature measurement ranges from -50 °C and up to 100 °C as well as customer specified ranges are available. Thanks to their simplicity, small size, and affordable price, TSR, TSR1, TSOR, and TSOR1 are applicable for various indoor applications, room temperature control, control board temperature measurement, etc.
Technical specifications Input
Power supply
Incorporated RTD Measurement range Range on request
Output Signal type Linearity proportional to Output at sensor burnout Output at sensor shorted
Pt100 or Pt1000 (w=1.385) -50...50 °C; 0...50 °C; -20...60 °C; 0...100 °C (1); -50...100 °C (1) minimum span 50 °C (transmitter only) 4...20 mA, 2-wire measured value 32 mA 0.2 mA
Accuracy
(transmitter only)
Electronic measurement error RTD measurement error Non-linearity Self-heating error Temperature drift (2) (3)
Ambient temperature Ambient humidity Directives
Design and materials Sensor sheath Housing material Wiring Mounting Dimensions Weight Protection class
-30...65 °C 5...85 %RH CE (2004/108/EC), LVD (2006/95/EC) TS(O)R TS(O)R1 copper none (hidden sensor) plastic plastic plug-in terminal hidden terminal free (3) free (3) 40x75x26 mm 40x75x26 mm (w/o terminal) max. 30 g max. 45 g IP20 IP44 (excl. terminal)
Not available for TSOR and TSOR1. Which is greater DIN-rail mounting accessory is also available (see 'Accessories')
Ordering code
TS - G2.G3.G11
Code Feature or option
Code values
Variant
R - RTD probe, R1 - low-cost RTD probe, OR - temperature transmitter, OR1 - low-cost temperature transmitter
G2
Sensor (4)
RD - Pt100, RG - Pt1000
G3
Temperature range
T10 - -20...60 °C, T17 - -50...50 °C, T18 - 0...50 °C, T19 - 0...100 °C (1), T12 - -50...100 °C (1), TZ - other (specify, ΔT ≥ 50 °C)
G11
Accuracy class
A - 'A', B - 'B', C - '2xB'
(4)
Operating conditions
Do not code for TSOR and TSOR1.
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(1)
0.2% from span or 0.2 °C (2) according to accuracy class within measurement error 0.02%/mA at 24 V 0.02% from span for 1 °C
10...32 VDC 1 Vp-p at 50 Hz 750 Ω at 24V/20mA
Loop voltage Admissible variations Maximum line load
temperature probes RTD Probe with Current Output TSOK ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
Pt100 or Pt1000 sensitive element 2-wire 4…20 mA output Easy & Fast connection plug M12 Vibration-proof design Small dimensions Extended design for higher temperature available High protection class - IP65 Local indicator available
TSOK measures temperature by the means of a Ptx sensitive element and converts it into standard 4...20 mA 2-wire current signal. This transmitter has a robust vibration-proof stainless steel sheath with IP65 protection class, and is equipped with a DIN 43650 connector that allows fast and easy electrical decoupling. The probe interior is filled with special compound, which protects the electronics from the harsh ambient influences. Eight different temperature measurement ranges from -50 °C and up to 400 °C as well as customer specified ranges are available. Various stem diameters and lengths as well as stainless steel types are also available. A local loop-powered indicator TI200 can be optionally mounted between the sheath top and the connector. Thanks to its small size and robust design, TSOK is applicable for cars, rail vehicles, construction machines, and other industrial equipment.
Technical specifications Input
Power supply
Input (RTD) type Measurement range
Pt100 or Pt1000 (w=1.385), class B -50...50 °C; -20...60 °C; 0...50 °C; 0...100 °C; -50...100 °C; 0...150 °C; 0...200 °C; 0...300 °C (1); 0...400 °C (1,5) minimum span 50 °C
Range on request
Output Signal type Linearity proportional to Output at sensor burnout Output at sensor shorted
4...20 mA, 2-wire measured value 32 mA 0.2 mA
Accuracy 0.2% from span or 0.2 °C (2) within measurement error 0.01% from span for 1 °C
Measurement error Non-linearity Temperature drift
(2)
max. 25 bar -40...85 °C 0...98 %RH according to EN 61000, EN 61010
Design and materials Sensor sheath Wiring Mounting thread Stem diameter Stem length Extension length (1) Protection class
stainless steel 4-pin detachable connector DIN 43650 M16, M18, M20, 3/8”, 1/2”, or other 6 or 8 mm 20...300 mm 50...100 mm IP65
Code values
Variant
K - short-design, K1 - extended-design
G3
Temperature range
T17 - -50...50 °C, T10 - -20...60 °C, T18 - 0...50 °C, T19 - 0...100 °C, T12 - -50...100 °C, T20 - 0...150 °C, T7 - 0...200 °C, T23 - 0...300 °C (1), T8 - 0...400 °C (1,5), TZ - other (specify, ΔT ≥ 50 °C)
G4
Stem diameter 'd' [mm]
6, 8
G6
Stem length 'n' [mm]
20 (3)…300 (step 5 mm)
G7
Extension length 'm' [mm] (1)
G9
(5)
Medium pressure Ambient temperature Ambient humidity EM compatibility and safety
TSO - G3.G4.G6.G7.G9.G10.G14 - #1.#2
Code Feature or option
(4)
Operating conditions
Only for the extended-design variant! Which is greater
Ordering code
(3)
10...32 VDC 1 Vp-p at 50 Hz 750 Ω at 24V/20mA
Mounting thread
50…100 (step 5 mm)
cylindrical (15 mm length)
Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", QZ - other (specify!)
tapered (standard length)
Q9 - 3/8" NPT, Q10 - 1/2" NPT, QZ - other (specify!)
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
G14
Tip shape
X - standard closed, N - narrowed
#1
Options
X - none, OP - electrochemically polished sheath surface
#2
Local indicator TI200
X - none, A - local indicator TI200 (4)
Minimum thread length + 5 mm! See TI200 specifications and order separately! Contact COMECO!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(1)
Loop voltage Admissible variations Maximum line load
temperature probes Programmable RTD Probe with Current Output TSOJ ♦ ♦ ♦ ♦ ♦ ♦ ♦
Programmable conversion range 2-wire 4…20 mA output Easy & Fast connection plug Straight or angled cable connector Small dimensions Vibration-proof design High protection class - IP65
TSOJ measures temperature within the -50...200 °C range via a Pt100 sensitive element and converts it into standard 4...20 mA 2-wire signal. The configuration software "TraCon" enables programming of the measurement range and output direction as well as other parameters. The probe has a robust vibration-proof stainless steel sheath with IP65 protection class, and its interior is filled with special compound, which protects the electronics from the harsh ambient influences. TSOJ is equipped with a detachable connector that allows fast and easy electrical decoupling. Various stem diameters and lengths as well as stainless steel types are available. Thanks to its robust design and flexible programming, the TSOJ probe is a fast and convenient solution to varying problems involving temperature measurement and conversion in industrial environments.
Technical specifications Input Input (RTD) type Measurement range Minimum programmable span
Output Signal type Maximum load Sensor failure reaction
(programmable) Pt100 (w=1.385) min. -50...max. 200 °C, programmable 50 °C (programmable) 4...20 mA or 20...4 mA, 2-wire 800 Ω at 24V/20mA < 3.9 or > 20.2 mA, programmable
Accuracy
Power supply 10...32 VDC 1 Vp-p at 50 Hz
Loop voltage Admissible variations
RS232, requiring special cable (2) "TraCon", free
Operating conditions Medium pressure Ambient temperature Ambient humidity EM compatibility
max. 25 bar -20...70 °C 0...95 %RH, non-condensing according to EN 61326
Case material Wiring Dimensions Mounting thread Stem diameter Stem length Protection class
stainless steel 4-pin detachable connector M12 or DIN 43650 (incl. female part) ø30x max. 66 mm (w/o stem and connector) M16, M18, M20, 3/8”, 1/2”, or other 6 or 8 mm 20...300 mm, step 5 mm IP65
Which is greater Ordered separately
Ordering code
TSOJ - G4.G6.G9.G10.G11.G14.G15 - #1
Code Feature or option
Code values
G4
Stem diameter 'd' [mm]
6, 8
G6
Stem length 'n' [mm]
20 (3)…300 (step 5 mm)
G9
Mounting thread
cylindrical (15 mm length)
Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", QZ - other (specify!)
tapered (standard length)
Q9 - 3/8" NPT, Q10 - 1/2" NPT, QZ - other (specify!)
G10
Sheath material
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4404
G11
Accuracy class (4)
A - 'A', B - 'B'
G14
Tip shape
X - standard closed, N - narrowed
G15
Wiring connector
C1A - angled connector M12, C1S - straight connector M12, C7 - DIN 43650 connector
#1
Options
X - none, OP - electrochemically polished sheath surface
(3)
Minimum thread length + 5 mm! (4) Of the built-in Pt100 sensor
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(2)
Interface type Configuration software
Design and materials 0.2% from span or 0.2 °C (1) according to the accuracy class within measurement error 0.01% from span for 1 °C
Measurement error RTD error Non-linearity Temperature drift
(1)
Serial interface
temperature probes
ROOM TEMPERATURE PROBE
TSUM
Case - plastic (ABS)
SENSITIVE ELEMENT
TEMPERATURE RANGE
1 x Pt (RB,RD,RF,RG)
T10
-10...60 °C
1 x Cu (RH, RK)
T10
-10...60 °C
SPECIFIC FEATURES
Room temperature measured value may be adjusted (increased or decreased) by the number pointed on the scale. The following designs exist according to maximum adjustment value: - up to ± 4 °C * - up to ± 8 °C * - up to ± 12 °C *
* Specify when ordering!
Ordering code
TSUM - G2
Code Feature or option Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100
COMECO reserves the right of changing specifications without prior notice!
G2
Code values
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
transmitters Infrared Temperature Transmitter TRU ♦ ♦ ♦ ♦ ♦ ♦ ♦
Low-temperature remote measurement Object temperature range from -10 to 150 °C Field of view 7.3 ° Linear current or voltage output signal Serial interface available Local programmable indicator available IP66 protection class
The TRU temperature transmitter's operation is based on the principle of sensing infrared radiation, emitted from a heated object, situated at a certain distance from the sensor, at a 7.3 ° conical angle. The sensitive thermopile element comprises of a multitude of thermocouples connected in series and allows measurement of the object surface temperature within the -10…150 °C range. The incorporated electronics converts the sensor output into a standard current or voltage signal suitable for further transmission and processing. Moreover, the transmitter may be equipped with programmable local LED indicator as well as with RS232 serial interface for data transmitting. By the means of specialized software, the information about the object's temperature may be viewed, stored, and printed from a PC. TRU is enclosed in a robust plastic box with connector, both with IP66, and is designed to be either freely mounted or mounted on DIN rail via special brackets. The TRU transmitter is very suitable for these special applications that require non-contact low-temperature-object measurement.
Technical specifications Input
Interface
Input type Material emission coefficient Object temperature range Calibrating distance Calibrating spot Field of view
object infrared emission 5...15 μm ≥ 0.85 min. -10...max. 150 °C 5 cm 3.5 cm 7.3 °
Analog output Output signal Output function Accuracy Temperature drift Maximum output load Output overload reaction
0(4)...20 mA or 0...10 V input signal info retransmission 2% from span 0.02% from span for 1 °C 750 Ω at 24V/20 mA display message
Local indicator (option) 3 LED indicators, 14 mm 1 °C 2 membrane keys
Digital display Display resolution Keyboard
Power supply Supply voltage Admissible variations Consumption
15...32 VDC 4 Vp-p at 50 Hz max. 120 mA
Operating conditions Ambient temperature Storage temperature
-10...65 °C -20...85 °C
Design and materials Case material Mounting Wiring Dimensions Weight Protection class
ABS/PC plastic free (1) 4-pin М12 connector 80x92x65 mm max. 250 g IP66
Radial, axial, and DIN-rail mounting accessories for 80x80x60 mm box can be ordered separately (see 'Accessories').
Ordering code
TRU - G9.G11 - #1
Code Feature or option
(2)
RS232 data transmission
Code values
G9
Serial interface
X - none, A - RS232
G11
Analog output
X - none (2), E - 0…20 mA, F - 4…20 mA, K - 0…10 V, Z - other on request
#1
Local indicator (2)
X - none, A - local indicator mounted
When no output is requested, local indicator must be ordered!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
(1)
Interface type Function
temperature probes ATEX (MI) RTD PROBE - FOR IN-HEAD TRANSMITTER **
TSCx - EX TSOCx - EX
II 2 G Ex d IIC T6 Gb -20°C≤Ta≤+65°C II 2 D Ex tb IIIC T80 °C Db IP65 EC-type Certificate No. MP 08 ATEX 0002
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
n [mm]
d [mm]
wires
Regular Design
DESIGN WITHOUT EXTENSION (TS(O)C) 1 x Pt (RB,RD,RF,RG)
2(3) x Pt (RB,RD,RF,RG)
for n < 150 mm, contact COMECO!
EXTENDED DESIGN WITH WELDED CONNECTION (TS(O)C1)
T9 T1 T24 T11 T2 T4 T22
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C
1 x Cu (RH, RK)
T9
-50...200 °C
2 x Cu (RH, RK)
T9
-50...200 °C
T12
-50...100 °C
1 x PTC (RP, RQ)
2 x Pt (RB,RD,RF,RG)
EXTENDED DESIGN WITH MOVABLE CONNECTION (TS(O)C2)
T9 T1 T24 T11 T2 T4 T22
4 5
2, 3*
50…1500
6
2, 3, 4*
50…3000 8, 10, 12, 14, 16, 20
2, 3, 4
6*, 8, 10
2x2(3)*
12, 14, 16, 20
2x2(3), 3x2
50…3000 50…1500
6
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C
2, 3, 4*
50…3000 8, 10, 12, 14, 16, 20 8, 10 12, 14, 16, 20 6 8, 10, 12, 14 8, 10, 12, 14
2x2 2x2(3)*
50...50000
3* 4.5 6 8
2, 3* 2, 3* 2, 3, 4* 2, 3, 4
50...50000
6, 8
2x2, 2x3*
50…3000
50…1500 50…3000 50…3000 MI Design
2 x PTC (RP, RQ)
1 x Pt (RB,RD,RF,RG)
50…500
2, 3 2x2
Protection head: EG(SS), EGS, EGW(SS), EX8(SS), EX8W(SS), EX10(SS), EX10W(SS), EX8WD, EX10WD (see Appendix - Protection Heads) Electrical entry: - cable gland(s): SS or brass, cemented, ID 7.5 mm - threaded head conduit(s) Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1
DESIGN WITH ADJUSTABLE CONNECTION (TS(O)C3)
Extension length: m = 0…1500 mm
Probe diameter 'd' Ext. length 'm' up to 50 mm 50...150 mm 150...500 mm 500+ mm
3, 4 mm
4.5...6 mm
8 mm
10 mm
10+ mm
8 8 10 14
d 8 10 14
d d 10 14
d d d 14
d d d d
Tip shape: standard or narrowed (see Appendix - Tip Shapes) Process pressure:
DESIGN WITH GLAND-TYPE CONNECTION (TS(O)C4)
Probe design Max. pressure *
TS(O)C, TS(O)C1 25 bar
TS(O)C2 16 bar
TS(O)C4 6 bar
TS(O)C3 0 bar
Sheath material: 1.4301(M1), 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362(M15) Wire material: Cu, Ni, or Ag Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) * Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Extension diameter: (for TS(O)C1 and TS(O)C2 only, [mm])
temperature probes
Ordering code
TS (1,2,3,4) - (MI -) G0'n0".G1G2.G3.G4.G6.G7.G9'9".G10.G11.G12.G13.G14 - #1.#2 - EX
Code Feature or option
Code values
Base model variant
C - standard (w/ terminal block), OC - prepared for in-head transmitter (w/o terminal block)
G0'
Protection head
EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", EX8 - type "EX8", EX8SS - type "EX8SS", EX8W - type "EX8W", EX8WSS - type "EX8WSS", EX10 - type "EX10", EX10SS - type "EX10SS", EX10W - type "EX10W", EX10WSS - type "EX10WSS", EX8WD - type "EX8WD", EX10WD - type "EX10WD"
G0"
Electrical entry ('n' - number of entries (12))
G - gland, U2 - M20x1.5, U4 - G1/2", U6 - G3/4", U10 - 1/2" NPT, U11 - 3/4" NPT
G1
Number of RTD sensors
1, 2, or 3 (11)
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100, RP - PTC 1k, RQ - PTC 2k
G3
Temperature range
T1 - -50…400 °C, T2 - -200…600 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C, T22 - -200…200 °C, T24 - -50…500 °C
G4
Diameter 'd' [mm]
G6 G7
Probe length 'n' [mm]
regular design
4, 5, 6, 8, 10, 12, 14, 16, 20
MI design
3 (11), 4.5, 6, 8
(1)
Probe length 'm' [mm]
50…50000 (see table overleaf)
(2)
0…1500 X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9'
Mounting connection
G9"
Compression fitting ferrule (4) regular design
BR - brass, GR - graphite, SS - stainless steel, TF - Teflon® M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404), M15 - 1.4362 (11)
G10
Sheath material (wetted parts)
G11
Accuracy class
X - none (5), A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (11)
(6)
MI design
M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404)
CU - copper (7), NI - nickel, AG - silver (8)
G13
Wire material
G14
Tip shape
X - standard closed, N - narrowed (8)
#1
Options
X - none, OV - vibration proof (spring terminals, MgO or Silicone filled, secured screws) (8), OT - thermal isolation (3), OP - electrochemically polished sheath surface (8)
#2
Incorporated devices
X - none, T - in-head transmitter (9), A - local indicator (10)
(1)
'n+m' for TS(O)C3 and TS(O)C4! Only for TS(O)C1 and TS(O)C2! Only for TS(O)C! (4) Only for TS(O)C4! (5) For non-Pt sensors (6) Only for Pt sensors! (7) Not applicable to non-MI (regular) RTDs for above 500 °C! (8) Only for non-MI (regular) design! (9) Only for variant 'OC'! See transmitter datasheets and order separately! (10) With windowed head only! See indicator datasheets and order separately! (11) Contact COMECO! (12) Applicable for the selected head type (see Appendix - Protection Heads) (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes ATEX (MI) T/C PROBE - FOR IN-HEAD TRANSMITTER **
TSCx - EX TSOCx - EX
II 2 G Ex d IIC T6 Gb -20°C≤Ta≤+65°C II 2 D Ex tb IIIC T80 °C Db IP65 EC-type Certificate No. MP 08 ATEX 0002
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
1(2) x J 1(2) x L
T4
0...800 °C
1(2) x K
T3 T16 T6*
0...850 °C 0...1100 °C 0...1150 °C
1(2) x E
T3 T13
0...850 °C 0...1000 °C
50...1500
6
50...3000
8, 10, 12, 14, 16, 20, 22
2 (2x2)
1(2) x S 1(2) x R
T16 T6*
0...1100 °C 0...1150 °C
50...1500 50...3000
6 8, 10, 12, 14, 16, 20, 22
2 (2x2)
T4
0...800 °C
50...50000
3, 4.5, 6, 8, 10*
T8
0...400 °C
50...50000
3, 4.5, 6, 8, 10*
0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C
50...50000
3, 4.5, 6, 8, 10*
2
2xK 2 x N, 2 x E
T3 T16 T6* T6*
50...50000
3, 4.5, 6, 8, 10*
2x2
2xS 2xR
T16 T6*
0...1100 °C 0...1150 °C
50...10000
3, 4.5, 6
2x2
n [mm]
d [mm]
wires
50...1500 50...3000
6 8, 10, 12, 14, 16, 20, 22
2 (2x2)
50...1500
6
50...3000
8, 10, 12, 14, 16, 20, 22
Regular Design
DESIGN WITHOUT EXTENSION (TS(O)C)
for n < 150 mm, contact COMECO!
2 (2x2)
MI Design
EXTENDED DESIGN WITH WELDED CONNECTION (TS(O)C1)
1xJ 2xJ 1xT 2xT 1xK 1 x N, 1 x E
2 2x2 2 2x2
Protection head: EG(SS), EGS, EGW(SS), EX8(SS), EX8W(SS), EX10(SS), EX10W(SS), EX8WD, EX10WD (see Appendix - Protection Heads)
EXTENDED DESIGN WITH MOVABLE CONNECTION (TS(O)C2)
Electrical entry: - cable gland(s): SS or brass, cemented, ID 7.5 mm - threaded head conduit(s) Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Extension length: m = 0…1500 mm Extension diameter: (for TS(O)C1 and TS(O)C2 only, [mm]) Probe diameter 'd' Ext. length 'm' up to 50 mm 50...150 mm 150...500 mm 500+ mm
3 mm
4.5, 6 mm
8 mm
10 mm
10+ mm
6 8 10 14
d 8 10 14
d d 10 14
d d d 14
d d d d
Tip shape (hot junction design): standard (isolated) (see Appendix - Tip Shapes) Process pressure:
DESIGN WITH GLAND-TYPE CONNECTION (TS(O)C4)
Probe design Max. pressure *
TS(O)C, TS(O)C1 25 bar
TS(O)C2 16 bar
TS(O)C4 6 bar
TS(O)C3 0 bar
Sheath material: 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762/1.4749(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362(M15) MI sheath material: 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762/1.4749(M4), 1.4841(M5), 1.4876(M7), 2.4816(M8), Nicrobell®(M10) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) * Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
DESIGN WITH ADJUSTABLE CONNECTION (TS(O)C3)
temperature probes
Ordering code TS (1,2,3,4) - (MI -) G0'n0".G1G2.G3.G4.G6.G7.G9'9".G10.G11 - #1.#2 - EX Code Feature or option
Code values
Base model variant
C - standard (w/ terminal block), OC - prepared for in-head transmitter (w/o terminal block)
G0'
Protection head
EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", EX8 - type "EX8", EX8SS - type "EX8SS", EX8W - type "EX8W", EX8WSS - type "EX8WSS", EX10 - type "EX10", EX10SS - type "EX10SS", EX10W - type "EX10W", EX10WSS - type "EX10WSS", EX8WD - type "EX8WD", EX10WD - type "EX10WD"
G0"
Electrical entry ('n' - number of entries (9))
G - gland, U2 - M20x1.5, U4 - G1/2", U6 - G3/4", U10 - 1/2" NPT, U11 - 3/4" NPT
G1
Number of thermocouples
1 or 2
G2
Thermocouple
G3
Temperature range
G4
Diameter 'd' [mm]
G6
Probe length 'n' [mm] (1)
G7
Probe length 'm' [mm]
regular design
E - type "E", J - type "J", K - type "K", L - type "L", R - type "R", S - type "S"
MI design
E - type "E", J - type "J", K - type "K", N - type "N", R - type "R", S - type "S", T - type "T" T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (8), T13 - 0…1000 °C, T16 - 0…1100 °C
regular design
6, 8, 10, 12, 14, 16, 20, 22
MI design
3, 4.5, 6, 8, 10 50…50000 (see table overleaf)
(2)
0…1500
G9'
Mounting connection
X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9"
Compression fitting ferrule (4)
BR - brass, GR - graphite, SS - stainless steel, TF - Teflon®
G10
Sheath material (wetted parts)
regular design
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4401 (1.4404), M15 - 1.4362
MI design
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M7 - 1.4876, M8 - 2.4816, M9 - 1.4401 (1.4404), M10 - Nicrobell®
G11
Accuracy class
1 - '1' (8), 2 - '2'
#1
Options
X - none, OV - vibration proof (spring terminals (8), secured screws), OT - thermal isolation (3), OP - electrochemically polished sheath surface (5)
#2
Incorporated devices
X - none, T - in-head transmitter (6), A - local indicator (7)
(1)
'n+m' for TS(O)C3 and TS(O)C4! Only for TS(O)C1 and TS(O)C2! Only for TS(O)C! (4) Only for TS(O)C4! (5) Only for non-MI (regular) design! (6) Only for variant 'OC'! See transmitter datasheets and order separately! (7) With windowed head only! See indicator datasheets and order separately! (8) Contact COMECO! (9) Applicable for the selected head type (see Appendix - Protection Heads) (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes ATEX RTD PROBE WITH (MI) INSERT - FOR IN-HEAD TRANSMITTER ** II 2 G Ex d IIC T6 Gb -20°C≤Ta≤+65°C II 2 D Ex tb IIIC T80 °C Db IP65
TSCSx - EX TSOCSx - EX
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
d insert [mm]
d [mm]
EC-type Certificate No. MP 08 ATEX 0002
wires
Regular Insert Design
DESIGN WITHOUT EXTENSION (TS(O)CS) 1 x Pt (RB,RD,RF,RG)
2 x Pt (RB,RD,RF,RG) for n < 150 mm, contact COMECO!
1 x Cu (RH, RK) 2 x Cu (RH, RK)
EXTENDED DESIGN WITH WELDED CONNECTION (TS(O)CS1) 1 x Pt (RB,RD,RF,RG)
2 x Pt (RB,RD,RF,RG)
T9 T1 T24 T11 T2 T4 T22
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C -50...200 °C
T9
-50...200 °C
T9
T9 T1 T24 T11 T2 T4 T22
8
4, 5
2, 3*
9, 10, 12, 14, 16, 20
6
2, 3, 4*
12, 14, 16, 20
8
2, 3, 4
9, 10, 12, 14, 16, 20
6
2x2*
12, 14, 16, 20
8
2x2(3)*
9, 10, 12, 14, 16, 20
6
2, 3, 4*
12, 14, 16, 20
8
2, 3, 4
9, 10, 12, 14, 16, 20
6
2x2*
12, 14, 16, 20
8
2x2(3)*
3*
2, 3*
MI Insert Design 6, 8, 9, 10, 12, 14, 16, 20 8, 9, 10, 12, 14, 16, 20 9, 10, 12, 14, 16, 20
-50...200 °C -50...400 °C -50...500 °C -50...600 °C -200...600 °C 0...800 °C -200...200 °C
4.5
2, 3*
6
2, 3, 4* 2, 3, 4
12, 14, 16, 20
8
9, 10, 12, 14, 16, 20
6
2x2, 2x3*
12, 14, 16, 20
8
2x2, 2x3*
Protection head: EG(SS), EGS, EGW(SS), EX8(SS), EX8W(SS), EX10(SS), EX10W(SS), EX8WD, EX10WD (see Appendix - Protection Heads)
EXTENDED DESIGN WITH MOVABLE CONNECTION (TS(O)CS2)
Electrical entry: - cable gland(s): SS or brass, cemented, ID 7.5 mm - threaded head conduit(s) Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Extension length: m = 0…1500 mm Extension diameter: (for TS(O)CS1 and TS(O)CS2 only, [mm]) Probe diameter 'd' Ext. length 'm'
6 mm
8 mm
9, 10 mm
10+ mm
up to 50 mm
d
d
d
d
50...150 mm
8
d
d
d
150...500 mm
10
10
d
d
500+ mm
14
14
14
d
Tip shape: standard or narrowed (see Appendix - Tip Shapes) Process pressure: Probe design
DESIGN WITH GLAND-TYPE CONNECTION (TS(O)CS4)
Max. pressure *
TS(O)CS, TS(O)CS1 TS(O)CS2 25 bar
16 bar
TS(O)CS4
TS(O)CS3
6 bar
0 bar
Sheath material: 1.4301(M1), 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4362(M15) Wire material: Cu, Ni, or Ag Accuracy class: 'A', 'B', or '2xB' (see Appendix - RTD Tolerance) * Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
DESIGN WITH ADJUSTABLE CONNECTION (TS(O)CS3)
temperature probes
Ordering code
TS (1,2,3,4) - (MI -) G0'n0".G1G2.G3.G4.G6.G7.G9'9".G10.G11.G12.G13.G14 - #1.#2 - EX
Code Feature or option
Code values
Base model variant
CS - standard (w/ terminal block), OCS - prepared for in-head transmitter (w/o terminal block)
G0'
Protection head
EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", EX8 - type "EX8", EX8SS - type "EX8SS", EX8W - type "EX8W", EX8WSS - type "EX8WSS", EX10 - type "EX10", EX10SS - type "EX10SS", EX10W - type "EX10W", EX10WSS - type "EX10WSS", EX8WD - type "EX8WD", EX10WD - type "EX10WD"
G0"
Electrical entry ('n' - number of entries (13))
G - gland, U2 - M20x1.5, U4 - G1/2", U6 - G3/4", U10 - 1/2" NPT, U11 - 3/4" NPT
G1
Number of RTD sensors
1 or 2
G2
Sensor
RB - Pt50, RD - Pt100, RF - Pt500, RG - Pt1000, RH - Cu50, RK - Cu100
G3
Temperature range
T1 - -50…400 °C, T2 - -200…600 °C, T4 - 0…800 °C, T9 - -50…200 °C, T11 - -50…600 °C, T22 - -200…200 °C, T24 - -50…500 °C
G4
Diameter 'd' / 'd insert' [mm]
G6 G7
Probe length 'n' [mm]
regular insert
8/4, 8/5, 9/6, 10/6, 12/6, 14/6, 12/8, 14/8, 16/6, 16/8, 20/6, 20/8
MI insert
6/3 (12), 8/4.5, 9/6, 10/6, 12/6, 14/6, 16/6, 16/8, 20/6, 20/8
(1)
Probe length 'm' [mm]
50…3000
(2)
0…1500 X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9'
Mounting connection
G9"
Compression fitting ferrule (4)
BR - brass, SS - stainless steel, TF - Teflon®
regular insert
M1 - 1.4301, M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404), M15 - 1.4362 (12)
MI insert
M2 - 1.4541, M3 - 1.4571, M9 - 1.4401 (1.4404)
G10
Sheath material (wetted parts and insert)
G11
Accuracy class
X - none (5), A - 'A', B - 'B', C - '2xB'
G12
Number of wires
2, 3, 4 (12)
(6)
CU - copper (7), NI - nickel, AG - silver (8)
G13
Wire material
G14
Tip shape
X - standard closed, N - narrowed (12)
#1
Options
X - none, OV - vibration proof (MgO or Silicone filled insert, secured screws) (8,9), OS - spring-loaded insert, OT - thermal isolation (3), OP - electrochemically polished wetted parts
#2
Incorporated devices
X - none, T - in-head transmitter (10), A - local indicator (11)
(1)
'n+m' for TS(O)CS3 and TS(O)CS4! Only for TS(O)CS1 and TS(O)CS2! Only for TS(O)CS! (4) Only for TS(O)CS4! (5) For non-Pt sensors (6) Only for Pt sensors! (7) Not applicable to non-MI (regular) RTD inserts for above 500 °C! (8) Only for non-MI (regular) inserts! (9) Requires 'OS' option! (10) Only for variant 'OCS'! See transmitter datasheets and order separately! (11) With windowed head only! See indicator datasheets and order separately! (12) Contact COMECO! (13) Applicable for the selected head type (see Appendix - Protection Heads) (2)
COMECO reserves the right of changing specifications without prior notice!
(3)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
temperature probes ATEX T/C PROBE WITH (MI) INSERT - FOR IN-HEAD TRANSMITTER ** II 2 G Ex d IIC T6 Gb -20°C≤Ta≤+65°C II 2 D Ex tb IIIC T80 °C Db IP65
TSCSx - EX TSOCSx - EX
DIMENSIONS SENSITIVE ELEMENT
TEMPERATURE RANGE
d [mm]
EC-type Certificate No. MP 08 ATEX 0002
d insert [mm]
wires
Regular Insert Design
DESIGN WITHOUT EXTENSION (TS(O)CS)
10, 12, 14, 16, 20
6, 8, 10
2
12, 14, 16, 20
8, 10
2x2
0...850 °C 0...1100 °C 0...1150 °C
10, 12, 14, 16, 20
6, 8, 10
2
12, 14, 16, 20
8, 10
2x2
0...850 °C 0...1000 °C
10, 12, 14, 16, 20
6, 8, 10
2
2xE
T3 T13
12, 14, 16, 20
8, 10
2x2
1xS 1xR
T16 T6*
0...1100 °C 0...1150 °C
10, 12, 14, 16, 20
6, 8, 10
2
2xS 2xR
T16 T6*
0...1100 °C 0...1150 °C
12, 14, 16, 20
8, 10
2x2
1 x J; 1 x L 2 x J; 2 x L 1xK 2xK 1xE
for n < 150 mm, contact COMECO!
EXTENDED DESIGN WITH WELDED CONNECTION (TS(O)CS1)
T4
0...800 °C
T3 T16 T6*
MI Insert Design 1xJ 2xJ 1xK 1 x N, 1 x E 2xK 2 x N, 2 x E
T4
0...800 °C
6, 8, 10, 12, 14, 16, 20
3, 4.5, 6, 8
T3 T16 T6* T6*
0...850 °C 0...1100 °C 0...1150 °C 0...1250 °C
8, 10, 12, 14, 16, 20
4.5, 6, 8
2 2x2 2 2x2
Protection head: EG(SS), EGS, EGW(SS), EX8(SS), EX8W(SS), EX10(SS), EX10W(SS), EX8WD, EX10WD (see Appendix - Protection Heads)
EXTENDED DESIGN WITH MOVABLE CONNECTION (TS(O)CS2)
Electrical entry: - cable gland(s): SS or brass, cemented, ID 7.5 mm - threaded head conduit(s) Process connection 'G' (nipple or union nut): - M16x1.5(Q0), M18x1.5(Q1), M20x1.5(Q2), M27x2(Q5), M33x2(Q25) - 3/8"(Q3/Q9), 1/2"(Q4/Q10), 3/4"(Q6/Q11), 1"(Q12/Q15) - welded or adjustable flange - other - w/o mounting appliances Thread length: - cylindrical thread: T = 15 mm - NPT thread: according to ANSI B1.20.1 Process length: n = 50…3000 mm
DESIGN WITH ADJUSTABLE CONNECTION (TS(O)CS3)
Extension length: m = 0…1500 mm Extension diameter: (for TS(O)CS1 and TS(O)CS2 only, [mm]) 6 mm
8 mm
10 mm
10+ mm
up to 50 mm
d
d
d
d
50...150 mm
8
d
d
d
150...500 mm
10
10
d
d
500+ mm
14
14
14
d
Insert tip shape (hot junction design): standard (isolated), grounded, open-tube, exposed (see Appendix - Tip Shapes) Process pressure:
DESIGN WITH GLAND-TYPE CONNECTION (TS(O)CS4)
Probe design Max. pressure *
TS(O)CS, TS(O)CS1 TS(O)CS2 25 bar
16 bar
TS(O)CS4
TS(O)CS3
6 bar
0 bar
Sheath material: 1.4401/1.4404(M9), 1.4541(M2), 1.4571(M3), 1.4762/1.4749(M4), 1.4841(M5), 1.4845(M6), 1.4876(M7), 2.4816(M8), 1.4362(M15) Accuracy class: '1' or '2' (see Appendix - T/C Tolerance) * Please contact COMECO! ** Order transmitter separately!!!
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,
COMECO reserves the right of changing specifications without prior notice!
Probe diameter 'd' Ext. length 'm'
temperature probes
Ordering code TS (1,2,3,4) - (MI -) G0'n0".G1G2.G3.G4.G6.G7.G9'9".G10.G11.G14 - #1.#2 - EX Code Feature or option
Code values
Base model variant
CS - standard (w/ terminal block), OCS - prepared for in-head transmitter (w/o terminal block)
G0'
Protection head
EG - type "EG", EGS - type "EGS", EGSS - type "EGSS", EGW - type "EGW", EGWSS - type "EGWSS", EX8 - type "EX8", EX8SS - type "EX8SS", EX8W - type "EX8W", EX8WSS - type "EX8WSS", EX10 - type "EX10", EX10SS - type "EX10SS", EX10W - type "EX10W", EX10WSS - type "EX10WSS", EX8WD - type "EX8WD", EX10WD - type "EX10WD"
G0"
Electrical entry ('n' - number of entries (9))
G - gland, U2 - M20x1.5, U4 - G1/2", U6 - G3/4", U10 - 1/2" NPT, U11 - 3/4" NPT
G1
Number of thermocouples
1 or 2
G2
Thermocouple
G3
Temperature range
G4
Diameter 'd' / 'd insert' [mm]
G6
Probe length 'n' [mm] (1)
G7
Probe length 'm' [mm]
regular insert
E - type "E", J - type "J", K - type "K", L - type "L", R - type "R", S - type "S"
MI insert
E - type "E", J - type "J", K - type "K", N - type "N" T3 - 0…850 °C, T4 - 0…800 °C, T6 - 0…1200 °C (8), T13 - 0…1000 °C, T16 - 0…1100 °C
regular insert
10/6, 10/8, 12/6, 12/8, 14/6, 14/8, 14/10, 16/10, 20/10
MI insert
6/3, 8/4.5, 10/6, 12/6, 14/6, 16/6, 20/6, 20/8 50…3000
(2)
0…1500
G9'
Mounting connection
X - no mounting appliances (3), Q0 - M16x1.5, Q1 - M18x1.5, Q2 - M20x1.5, Q3 - G3/8", Q4 - G1/2", Q5 - M27x2, Q6 - G3/4", Q9 - 3/8" NPT, Q10 - 1/2" NPT, Q11 - 3/4" NPT, Q12 - G1", Q15 - 1" NPT, Q25 - M33x2, Uxx - union nut (xx - same as for Qxx), F - flange (specify!), Z - other connection (specify!)
G9"
Compression fitting ferrule (4)
BR - brass, SS - stainless steel, TF - Teflon®
G10
Sheath material (wetted parts and insert)
regular insert
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M6 - 1.4845, M7 - 1.4876, M8 - 2.4816, M9 - 1.4401 (1.4404), M15 - 1.4362
MI insert
M2 - 1.4541, M3 - 1.4571, M4 - 1.4762 (1.4749), M5 - 1.4841, M8 - 2.4816, M9 - 1.4401 (1.4404)
G11
Accuracy class
1 - '1' (8), 2 - '2'
G14
Insert tip shape (hot junction)
X - standard (isolated from sheath), G - grounded, E - exposed hot junction, O - open-tube design
#1
Options
X - none, OV - vibration proof (secured screws) (5), OS - spring-loaded insert, OT - thermal isolation (3), OP - electrochemically polished wetted parts
#2
Incorporated devices
X - none, T - in-head transmitter (6), A - local indicator (7)
(1)
'n+m' for TS(O)CS3 and TS(O)CS4! Only for TS(O)CS1 and TS(O)CS2! (3) Only for TS(O)CS! (4) Only for TS(O)CS4! (5) Requires 'OS' option! (6) Only for variant 'OCS'! See transmitter datasheets and order separately! (7) With windowed head only! See indicator datasheets and order separately! (8) Contact COMECO! (9) Applicable for the selected head type (see Appendix - Protection Heads)
COMECO reserves the right of changing specifications without prior notice!
(2)
Comeco Inc., P.O.Box 378, Plovdiv 4000, BULGARIA,