HOLLY MUELLER NICOLE GUENTHER HOTEL DESIGN COMMERCIAL DESIGN I FALL 2020 MOORMAN
2
INDEX 01. Preliminary Design 02. Level One
15...Construction Documentation 18...Rendered Perspectivies
03. Double Bedroom
26.....Construction Documentation 30.....Rendered Perspectives
04. Suite
35.....Construction Documentation 38.....Rendered Perspectives
05. VIP Suite
44.....Construction Documentation 47.....Rendered Perspectives
3
PRELIMINARY PROCRESS
4
PROJECT OVERVIEW This existing hotel was built in Boston, Massachusetts in the 1950s and is in need of a top to bottom renovation. The area has been overdeveloped and lost commercial viability. We are in an attempt to bring a sense of life back into the area while also incorporating sustainable features to create a green enviornment. The Avalon will be a wonderful new addition to the area,
5
RESEARCH AND DEMOGRAPHICS The Avalon will be located in Boston, the capital of Massachuesetts.
Home to almost 700,000 residents
Sees almost 23 million visitors annually
Median household income is about $52,000
Third most densly populated city in the US
6
CONCEPT STATEMENT The concept for The Avalon was created by combining influences from Raphael and King Arthur. Raphael is an Italian painter and architect, best known for his Madonnas. King Arthur was a Britsh ruler in the fifth century, commonly known from his Knights at the Round Table and the legend of The Sword in the Stone. Taking elements from each of their time periods, we wanted to include feautures such as columns, crystal chandeliers, marble floors, solid woods, and rich colors. With a complimentary color scheme, including shades of green and red with gold accents.
7
CONCEPTUAL IMAGERY
8
SUSTAINABILITY FEATURES Materials & finishes have been warehoused for two weeks. Dual flush toilets and low flow shower heads have been included to help lower water consumption. Incorporation of biophilia to increase human health and well-being. Breakfast / restaurant will use locally farmed organic produce, poultry, fish, and meats. LED lighting takes energy efficiency into consideration. Bike Rental station for quality transportation to limit gas emissions. Ample amount of natural lighting. Within walking distance of local entertainment and attractions.
9
EXPLODED AXONOMETRIC
10
LEVEL ONE SPACE PLANNING BIKE RENTAL / CONCIERGE FAMILY RESTROMS CONFERENCE ROOMS GYM SINGLE ROOM BREAKFAST / DINING BAR LOUNGE / SEATING RECEPETION ENTRY
11
LEVEL THREE - SIXTEEN SPACE PLANNING VIP SUITE SUITE DOUBLE ROOM SINGLE ROOM ELEVATOR / STAIRS STORAGE CLOSET EMPLOYEE OFFICE VENDING / ICE
12
FIRE PROTECTION CHECKLIST Required Fire Protection
Existing
(yes or no)
Location in Building
(check those that apply)
Detection Systems: Smoke Detector/Alarms Fire Alarms Audio Systems Accessible Warning Systems
Quantities Required (Additional or new)
N/A Yes Yes Yes No
Ceiling Ceiling Ceiling Ceiling
Suppression Systems: Fire Extinguisher Standpipe Hose Sprinkler Systems Types of Sprinkler Heads Other:
Type of System Required
Additional Additional Additional New Standard Code
Yes Yes No Yes Yes
Lobby, Bar, Suites Kitchen Kitchen Ceiling Ceiling
Additional Additional New Additional Additonal
13
TILE SPECIFICATION SHEET General
1. Type of traffic expected: Heavy 2. Will tile be used on the stairs: No 3. Will there be concentrated traffic patterns: No 4. One-Way Traffic: No 5. Is plushness desired: No 6. Are employees walking on floor as part of daily work (i.e., retail, manufacturing, showroom, hospital): Yes 7. Will tile be exposed to direct sunlight: No 8. What kind of light will be used in the area: Natural; Incandescent 9. Has a budget been established: No
Healthy, Safety, and Comfort Factors Flammability
1. Will tile be used on the walls: Yes 2. Will tile be used on stairwell: No 3. Will tile be used on exit ramp: No 4. Will tile be used in a medical facility: N/A 5. Will fireplace or other open flame source be nearby: No 6. Is Hill-Burton federal funding to be used: No 7. Will sprinklers or other fire-prevention equipment be used in the area: Yes
Static
1. Is static control a necessity: No 2. Is static control for human comfort: No 3. Is static control for computer tape: No 4. Is static control for memory transmission machines: No 5. Is static control from heart monitoring equipment: No 6. Will there be some method of controlling humidity above 20 percent at 70 Degrees F: Yes 7. Will electric typewriters and metallic office equipment be used: No
Acoustics
1. Are airborne noises important to consider: Yes 2. Will impact noise reduction be important: No 3. Will area be used for public event or speeches: No 4. Will music listening be involved: No 5. Will a concentration of seating be prevalent: Yes
Installation
1. Type of floor: Tile 2. Grade Level: Ground Level 3. Does the floor contain utilities: No 4. Type of building: Existing 5. Is carpet presently on floor: No 6. Will old tile be removed: Yes 7. Will this disrupt operations: No 8. Could a direct cement (no pad) installation be used: N/A 9. Is pattern an important feature in the design criteria: Yes 10. Will mechanical access to trench header ducts be required: No 11. Will portions be fastened to the floor: Yes 12. Will there be wheeled traffic: No 13. Will wheeled traffic move directly from street to tile: No 14. In office areas, will chairs have casters: No
LEVEL ONE
15
LOBBY DIMENSION FLOOR PLAN
SCALE NOT SPECIFIED FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS
16
LOBBY TITLE REFLECTED CEILING PLAN TARAXACUM DIMMABLE PENDANT BY FLOS
PARALLEL CYLINDER PENDANT LIGHT BY HENNEPIN MADE
ACOUTSIC CEILING TILE
BEETHOVEN CHROME CRYSTAL CHANDELIER BY MEYDA
PENDANT A
COFFERED CEILING TILE
CUSTOM LIGHT
PENDANT B
RECESSED CAN LIGHT BY DALS LIGHTING
SCALE NOT SPECIFIED FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS
CRYSTAL CHANDELIER
17
TITLE LOBBY ELEVATIONS RECEPTION - NORTH WALL
18' - 0"
22' - 0"
www.autodesk.com/revit
Consultant Address Address Address Phone
-
Consultant Address Address Address Phone
Consultant Address Address Address Phone
4' - 0"
Consultant Address Address Address Phone
Consultant Address Address Address Phone
20' - 0" 1' - 5 1/2"
LOBBY - SOUTH WALL
17' - 7 1/2"
Description
Date
-
2' - 11"
22' - 0"
No.
-
Owner 9' - 6 1/2"
2' - 5 3/4"
9' - 6 1/2"
2' - 7"
9' - 6 1/2"
2' - 8"
9' - 6 1/2"
2' - 5 1/2"
9' - 6 1/2"
2' - 7"
9' - 6 1/2"
SCALE NOT SPECIFIED FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS
Project Name
18
19
20
21
22
23
24
LEVEL THREE - SIXTEEN DOUBLE BEDROOM
26
DIMENSIONED TITLE FLOOR PLAN 22' - 2 11/16" 16' - 2 11/16"
6' - 0"
3' - 0" 2' - 6"
1
8' - 6"
13' - 8 11/16"
23' - 6"
E5
3' - 0"
-
21' - 0"
4' - 0"
E6 E7
E8
4' - 8"
BATH
3' - 4"
8' - 0"
2
3
5' - 9"
2' - 9"
6' - 7 11/16"
8' - 6" SCALE NOT SPECIFIED FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS
5' - 2"
13' - 8 11/16" 22' - 2 11/16"
1' - 11"
23' - 6"
BDRM
4' - 0"
15' - 6"
ENTRY
27
TITLE FURNISHINGS PLAN
SCALE NOT SPECIFIED FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS
28
REFLECTED TITLE CEILING PLAN
FLOS PENDANT
PEDANT
COFFERED CEILING TILE
RECESSED LIGHTING
M
SCALE NOT SPECIFIED FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS
29
TITLE ELEVATIONS BEDROOM - WEST WALL
SCALE NOT SPECIFIED FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS
VANITY - WEST WALL
30
31
32
33
LEVEL THREE - SIXTEEN SUITE
35
TITLE DIMENSION FLOOR PLAN 27' - 3"
3' - 6"
9' - 9"
8' - 9"
7' - 6"
13' - 8"
3' - 0"
KITCHEN
1 18' - 6"
ENTRY
18' - 9 7/8"
2
8' - 6 11/16"
BDRM BATH
3
5' - 9"
SCALE NOT SPECIFIED FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS
3' - 0"
27' - 6 7/8"
8' - 9"
4' - 0"
20' - 0 7/8"
27' - 6 7/8"
11' - 6 5/32"
8' - 9"
3' - 11"
5' - 2" 27' - 3"
9' - 5"
36
FURNISHINGS TITLE PLAN
SCALE NOT SPECIFIED FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS
37
TITLE REFLECTED CEILING PLAN
PENDANT
COFFERED CEILING TILE
FLOS PENDANT
RECESSED LIGHTING
M
SCALE NOT SPECIFIED FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS
38
39
40
41
42
LEVEL THREE - SIXTEEN VIP SUITE
44
TITLE DIMENESIONED FLOOR PLAN 56' - 6 7/16" 22' - 5 29/32" 9' - 3 19/32"
13' - 2 5/16"
34' - 0 9/16" 3' - 0"
17' - 8 1/4"
13' - 4 5/16"
12' - 10"
BDRM1 3' - 0"
16' - 11 3/8"
KITCHEN
BATH1
LIVING 3' - 0" 11' - 6" 3' - 0"
21' - 10 5/16"
BDRM2
BATH2 4' - 0"
3' - 3 13/16"
18' - 11 23/32" 22' - 3 9/16"
13' - 6" 35' - 9 9/16"
SCALE NOT SPECIFIED FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS
57' - 7 27/32"
13' - 6"
13' - 3"
3' - 0" 3' - 8" 2' - 6"
40' - 11 3/8"
5' - 2"
14' - 10 3/8"
3' - 0"
DINING
8' - 0"
24' - 11 3/8"
4' - 0"
45
FURNISHINGS PLAN
SCALE NOT SPECIFIED FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS
46
REFLECTED CEILING PLAN
FLOS PENDANT
CHANDELIER
SCALE NOT SPECIFIED FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS NOTE: CEILING IS COFFERED
RECESSED LIGHTING
47
48
49
50
51
Thank You