Saurer 5040 E Technical Data Machine types
Standard Pentamat
without embroidering position selector automatic embroidering position selector
Options:
• Universal roller cloth system FastSpan, suitable to all common roller cloths; device for fabric pull-through • Cone carriers: 4/4, 8/4, 12/4 Fabric winding device: • DUPLEX fabric winding device (electric wind-up and roll-over device) • manual wind-up and roll-over device
Illustration
Specifications
Embroidery length
[yard] [m]
No. of embroidering positions
25
Fabric shaft length
[m]
14.73
20.68
[t]
22.0
27.0
[1/min]
280
250
The speed depends on the article to be manufactured, the yarns used and the operating conditions.
Embroidery height
[mm]
2 x 1250
Machine height
from finished floor
[m]
4.75
Room height
minimum
[m]
4.80
Machine width
catwalk incl. stairs
[m] [m]
2.35 3.75
Oerlikon Saurer Arbon Ltd. Textilstrasse 2 9320 Arbon, Switzerland Phone +41 71 447 51 11 Fax +41 71 447 54 11 www.saurer.oerlikontextile.com info@saurerarbon.com DS0.0154.E00 05/09 Subject to technical modifications
·
2 x 744
19
1)
·
2 x 524 [m]
Maximum speed 1)
·
22.0 20.1
Machine length Net weight (approx.)
·
15.5 14.2
·
Saurer 5040 E Technical Data General technical data
Smallest needle repeat: 4/4 french inch = 27.07 mm Lateral movement: max. 96/4 repeat = 649.7 mm Only possible without tension rod sensors and with adaptations according to DAI.0134.E00. Smallest stitch unit: 0.1 mm horizontally and vertically Boring depth: 0 to 20 mm stepless (= max. Ø 4.2 mm with borer 12%)
Control system
Operation: Color touch screen monitor, manual control unit, foot switch, manual switch Thread monitor: Standard: segmental monitoring on each level Pentamat: OptiPoint (single embroidering position monitoring)
Connections
Electrical supply: 3 x 400 VAC +/- 10% + PE 50/60 Hz +/- 2% A transformer is needed for other voltages (option)! We recommend using an UPS for the entire company. Overvoltage protection in accordance with our specification is required.
Fabric shaft-Ø: without cloth: 92 mm; wound with fabric: max. 120 mm Spool sizes: normal: Ø 50 x 85 mm Cones: Ø 125 x 230 mm (4/4) Ø 150 x 230 mm (8/4, 12/4) Shuttles: Saurer "Silenzio" Bobbin size: 43 0/-0.2 x 14.7 0/-0.2 mm
Data format: Standard Highlevel Code (SHC) Data interface: LAN; USB; diskette
Pre-fusing: 25 A time-delay 3 phases (supply wire gauge min. 4 x 6 mm2) If local regulations require the installation of RCCB's, use an RCCB with a sensitivity of 300 mA, selective, pulse-power stable and inverter proof. Compressed air (customer): Compressed air supply 7 to 10 bar
For further specifications refer to document DS0.0170.E00.
DS0.0154.E00 05/09
Subject to technical modifications