JRG VENTILPROGRAM

Page 1

09050 - 15.06.2009

JRG VENTILPROGRAM

VENTILPROGRAM FOR BLANDET TAPPEVANN



Ventilprogram

Innhold

Ventileksempler................................................................... 2 Blandeventilen..................................................................... 3 Løsningsforslag..................................................................... 4 Dimensjonering.................................................................... 5 Prinsippskisser....................................................................... 6 Dusjeksempler...................................................................... 8 Teknisk.................................................................................. 9 Problemløsning.................................................................. 11 Notater................................................................................ 12


Ventilprogram

Ventileksempel Blandeventil JRGUMAT® / bronse

• Leveres med kuplinger • Leveres med isolasjonskappe • DN 15 - DN 80 • Nøyaktighet +/- 1°C ved riktig dimensjonering • Kan leveres kuplinger til andre typer rør og fittings • Kan monteres i alle retninger • Den mest driftssikre ventilen på markedet

3400

Skråseteventil JRG Legiostop® / bronse • Syrefast spindel • Ingen vannlommer • Gjenge i spindel sitter utenfor vått område, den vil derfor ikke sette seg fast • Kan gjøres om til tilbakeslagsventil • DN 15 - DN 50 • Leveres med utvendig gjenge, innvendig gjenge, MT kupling. Andre kuplingstyper på forespørsel

5221

Skråseteventil JRG Legiostop® / bronse m/tilbakeslagsventil • Syrefast spindel • Ingen vannlommer • Gjenge i spindel sitter utenfor vått område, den vil derfor ikke sette seg fast • DN 15 - DN 50 • Leveres med utvendig gjenge, innvendig gjenge, MT kupling. Andre kuplingstyper på forespørsel

5266

Termisk ventil JRGUTHERM® / bronse • Brukes til å styre sirkulasjonen • Sørger for riktig sirkulasjonstemperatur • DN 15 . DN 20 • Innstilles ca 5º over blandeventilens temperatur

6320

Reguleringsmuffe, JRG / bronse

• Nåleventil som brukes til å styre vannmengden i sirkulasjonsledningen • DN 15 . DN 20

6310

Reduksjonsventil JRGURED® / bronse • Kan brukes for å redusere vanntrykket i alle installasjoner • type 1300 for vann inntil 30ºC • type 1310 for vann fra 30 til 70ºC 1300

2

1310


Ventilprogram

Blandeventilen JRGUMAT® blandeventiler leveres i støpt bronse og bør monteres i alle anlegg der det kreves jevn temperatur og høyeste krav til funksjon og levetid.

3

1

6

2 B

A

C

5

4

1

Økonomisk

Miljøvennlig

Høy kvalitet

Lang levetid

A Termostat B Ventilskive bronse C Stang syrefast stål 1 2 3 4 5 6

Ventilhus bronse Reguleringssylinder Justeringsskrue messing Kaldtvannssete syrefast stål Varmtvannssete bronse Sirkulasjonshylse kunststoff, tilkobles med kupling kat.nr. 8201

JRGUMAT® har forhåndsinnstilt temperatur fra fabrikken. Innstilte temperatur står på justeringsskiven på toppen av ventilen (1). Nedenforstående tabell viser temperaturendringer ved en omdreining av justeringsskruen.

2 Forhåndsinnstilt Mulig innstilling Temperaturendring temperatur ºC temperatur °C ved 1 omdreining GN ½-1 GN 1½-2 DN 15-25 DN 32-50 DN 65-80 25 20-30 40 30-45 48 36-53 ca.6K ca.4K ca.2K 55 45-65

1

2

3


Ventilprogram Alternativer ved 1” Anbefalt blandeventil for: Nød-/øyedusj; forhåndsinnstilt 25ºC Dusjanlegg; forhåndsinnstilt 40ºC Forbruksvann; forhåndsinnstilt 55ºC

Løsningsforslag JRGUMAT® 3400

Antall Beskrivelse NRF.nr. 1 Blandeventil 1” m/kupling 25ºC (20-30ºC) 445 11 13 Blandeventil 1” m/kupling 40ºC (30-45ºC) 445 11 16 Blandeventil 1” m/kupling 55ºC (45-65ºC) 445 11 19

Skråseteventil m/tilb.sl.v. JRG Legiostop® Antall Beskrivelse 2 Skråseteventil m/tilb.sl.v. DN 25 1”

Deler for sirkulasjonskobling

Antall Beskrivelse 1 Reguleringsventil ½” 3 Kupling ½” u/avst. f/6320 2 Skråsetventil m/tilb.sl.v. DN 15 ½”

Alternativer ved 1¼” Anbefalt blandeventil for: Nød-/øyedusj; forhåndsinnstilt 25ºC Dusjanlegg; forhåndsinnstilt 40ºC Forbruksvann; forhåndsinnstilt 55ºC

Antall Beskrivelse NRF.nr. 1 Blandeventil 1¼” m/kupling 25ºC (20-30ºC) 445 11 23 Blandeventil 1¼” m/kupling 40ºC (30-45ºC) 445 11 26 Blandeventil 1¼” m/kupling 55ºC (45-65ºC) 445 11 29

Antall Beskrivelse 2 Skråseteventil m/tilb.sl.v. DN 32 1¼”

Deler for sirkulasjonskobling

Antall Beskrivelse 1 Reguleringsventil ½” 3 Kupling ½” u/avst. f/6320 2 Skråseteventil m/tilb.sl.v. DN 15 ½”

Anbefalt blandeventil for: Nød-/øyedusj; forhåndsinnstilt 25ºC Dusjanlegg; forhåndsinnstilt 40ºC Forbruksvann; forhåndsinnstilt 55ºC

NRF.nr. 554 51 32

NRF.nr. 445 12 53 445 12 63 554 51 28

JRGUMAT® 3400

Antall Beskrivelse NRF.nr. 1 Blandeventil 1½” m/kupling 25ºC (20-30ºC) 445 11 33 Blandeventil 1½” m/kupling 40ºC (30-45ºC) 445 11 36 Blandeventil 1½” m/kupling 55ºC (45-65ºC) 445 11 39

Skråseteventil m/tilb.sl.v. JRG Legiostop® Antall Beskrivelse 2 Skråseteventil m/tilb.sl.v. DN 40 1½”

Deler for sirkulasjonskobling

Antall Beskrivelse 1 Reguleringsventil ½” 3 Kupling ½” u/avst. f/6320 2 Skråseteventil m/tilb.sl.v. DN 15 ½” 4

NRF.nr. 445 12 53 445 12 63 554 51 28

JRGUMAT® 3400

Skråseteventil m/tilb.sl.v. JRG Legiostop®

Alternativer ved 1½”

NRF.nr. 554 51 31

NRF.nr. 554 51 33

NRF.nr. 445 12 53 445 12 63 554 51 28


Ventilprogram

Dimensjonering

Avvikstoleranse

Trykktap

Avvikstoleranse +/- 1

Tabell for JRGUMAT® - blandeventilene 3400, 3408, 3410 og 3412

Vannmengde

Anbefalt vannmengde på JRGUMAT® 3100/3400 ved 4-5 bars trykk på varmt og kaldt vann

½” Blandeventil ¾” Blandeventil 1” Blandeventil 1¼” Blandeventil 1½” Blandeventil 2” Blandeventil

JRGUMAT® DN15 JRGUMAT® DN20 JRGUMAT® DN25 JRGUMAT® DN32 JRGUMAT® DN40 JRGUMAT® DN50

5 - 30 8 - 55 15 - 90 35 - 180 50 - 250 70 - 320

liter/min. liter/min. liter/min. liter/min. liter/min. liter/min.

Beregning av tappemengde og dimensjon Eksempel Dusjanlegg - - - -

40 stk dusjer forbruker 8 liter/dusj/minutt (forblandet vann deles inn i soner). 10 dusjer i hver sone. Det for å få stabilt temperert vann 10 stk dusjer x 8 liter/min = 80 l/min 80 l/min på beregningstabell viser 1¼" JRGUMAT ventil

NB! Monter blandeventilen så nærme dusjsonen som mulig for å få kortest ventetid frem til dusjene. 5


Ventilprogram

Prinsippskisser

Viktige punkter i anlegg uten sirkulasjon:

• Ved trykkforskjell mellom KV og VV større enn 0,5 bar skal det brukes reduksjonsventil. • JRG Legiostop tilbakeslagsventil skal benyttes. • JRGUMAT blandeventil skal alltid monteres minimum en meter fra varmtvanskilde.

ill. 1

Viktige punkter i anlegg med sirkulasjon:

• Stabil temperatur på hele strekket gir kort responstid • Ventiler justeres slik at 20% av sirkulasjonen er via varmtvannskilde, energiøkonomisk. • JRG 6320 reguleringsventil sikrer korrekt temperatur på sirkulasjonsledningen.

6

ill. 2


Ventilprogram

Prinsippskisser

Bypass for desinfeksjon Termisk desinfeksjon:

• For å kjøre hettvann gjennom JRGUMAT®, stenges ventil nr.1 og ventil nr. 2 åpnes. Da tvinges hettvann inn på kald side av blandeventilen, slik at både ventiler og rørstrekk desinfeseres. • Etter fullført desinfeksjon (oppnådd 70ºC i 5min. ved tappested), stenges ventil nr. 2 og ventil nr. 1 åpnes.

NB!

ill. 3

Normaldrift: Ventil nr. 1: åpen Ventil nr. 2: stengt Ventil nr. 3: åpen Ventil nr. 4: stengt

Desinfeksjon: Ventil nr. 1: stengt Ventil nr. 2: åpen Ventil nr. 3: stengt Ventil nr. 4: åpen

7


Ventilprogram

Dusjeksempel

ill. 4 Anlegg med forblandet/temperert vann hvor det ogs책 skal benyttes dusjer uten blandebatteri (kretsen p책 venstre side).

Termisk desinfeksjon krever tilleggsinstallasjon, se ill.3 foreg책ende side. Et anlegg som skissert over trenger denne tilleggsinstallasjonen for begge kretser!

ill. 5 8


Ventilprogram

Teknisk Blandeventil 3400 NRF 445 11 03 445 11 06 445 11 09 445 11 13 445 11 16 445 11 19 445 11 23 445 11 26 445 11 29 445 11 33 445 11 36 445 11 39 445 11 43 445 11 46 445 11 49

Kat.nr. 3400.920 3400.922 3400.926 3400.930 3400.932 3400.936 3400.940 3400.942 3400.946 3400.950 3400.952 3400.956 3400.960 3400.960 3400.960

GN ¾ ¾ ¾ 1 1 1 1¼ 1¼ 1¼ 1½ 1½ 1½ 2 2 2

DN 20 20 20 25 25 25 32 32 32 40 40 40 50 50 50

d2 G 1 ¼ G 1 ¼ G 1 ¼ G 1 ½ G1½ G 1 ½ G2 G2 G2 G 2 ¼ G 2 ¼ G 2 ¼ G 2¾ G 2¾ G 2¾

d3 G½ G½ G½ G¾ G¾ G¾ G¾ G¾ G¾ G ¾ G ¾ G ¾ G ¾ G ¾ G ¾

h1 32 32 32 36 36 36 41 41 41 50 50 50 60 60 60

h2 49 49 49 51 51 51 75 75 75 77 77 77 85 85 85

h3 40 40 40 43 43 43 52 52 52 58 58 58 70 70 70

l 100 100 100 110 110 110 78 78 78 150 150 150 180 180 180

l1 40 40 40 43 43 43 8 8 8 58 58 58 70 70 70

l2 60 60 60 67 67 67 78 78 78 92 92 92 110 110 110

ºC 25 40 55 25 40 55 25 40 55 25 40 55 25 40 55

Skråseteventil m/tilbakeslagsventil NRF 554 51 28 554 51 29 554 51 31 554 51 32 554 51 33 554 51 34

Kat.nr. 5266.240 5266.320 5266.400 5266.480 5266.560 5266.640

GN ½ ¾ 1 1¼ 1½ 2

DN 15 20 25 32 40 50

d1 Rp½ Rp¾ Rp1 Rp1¼ Rp1½ Rp2

d2 G ½ G¾ G1 G1¼ G1½ G2

d3 Rp¼ Rp ¼ Rp ¼ Rp ¼ Rp ¼ Rp ¼

d4 53 53 60 70 90 90

h L1 86,5 65 104.5 75 116.5 90 130 110 147.5 120 169 150

L2 45,5 56 59 58.5 67 67

Z 37 45 54 70 80 100

Z1 Z2 10 27 12 33 14,5 39,5 18.5 51,5 19.5 60,5 23 77

l2 45.5 56 59 58,5 67 67

Z1 10 12 14,5 18,5 19,5 23

Skråseteventil NRF 554 51 02 554 51 03 554 51 04 554 51 05 554 51 06

Kat.nr. GN DN 554 51 01 5221.240 ½ 5221.320 ¾ 20 5221.400 1 25 5221.480 1¼ 32 5221.560 1 ½ 40 5221.640 2 50

d1 15 Rp ¾ Rp 1 Rp 1¼ Rp 1½ Rp 2

d2 Rp ½ G ¾ G 1 G 1¼ G 1½ G 2

d3 G ½ Rp ¼ Rp ¼ Rp ¼ Rp ¼ Rp ¼

DN d1 15 G ¾ 20 G1

h 64 64

l 60 60

DN d1 15 Rp ½ 20 Rp¾

d2 32 36

h 50 61

d4 53 53 60 70 90 90

h l1 86.5 65 104,5 75 116,5 90 130 110 147,5 120 169 150

Z2 27 33 39,5 51,5 60,5 77

Reguleringsventil NRF Kat.nr. GN 445 12 53 6320.914 ½ 445 12 54 6320.924 ¾

Reguleringsmuffe NRF Kat.nr. GN 554 50 42 6310.240 ½ 6310.320 ¾

l 54 64

z 14 8 17 12

9


Ventilprogram

Teknisk Reduksjonsventil NRF 563 22 04 563 22 06 563 22 08 563 22 11 563 22 13 563 22 15

Kat.nr. t max °C 1300.240 30 1300.320 30 1300.400 30 1300.480 30 1300.560 30 1300.640 30 1310.240 70 1310.320 70 1310.400 70 1310.480 70 1310.560 70 1310.640 70

DN 15 20 25 32 40 50 15 20 25 32 40 50

d1 R ½ R ¾ R 1 R 1¼ R 1½ R 2 R 2½ R ¾ R 1 R 1¼ R 1½ R 2

d2 G ¾ G 1 G 1¼ G 1½ G 1¾ G2 ⅜ G¾ G 1 G 1¼ G 1½ G 1¾ G2 ⅜

d3 d4 Rp ⅛ 52 Rp ⅛ 58 Rp ¼ 70 Rp ¼ 77 Rp ¼ 93,5 Rp ¼ 103 Rp ⅛ 52 Rp ⅛ 58 Rp ¼ 70 Rp ¼ 77 Rp ¼ 93,5 Rp ¼ 103

l1 148 159 184 212 241 289 148 159 184 212 241 289

l2 34 37 42 46 48 57 34 37 42 46 48 57

z 40 42,5 50 60 72,5 87,5 40 42,5 50 60 72,5 87,5

h1 33,5 42 51,5 64 80 98 28,5 35,5 51,5 64 80 98

h2 78,5 85,5 110 120,5 157 172 78,5 85,5 110 120,5 157 172

Blandeventil NRF 445 11 53 445 11 56 445 11 59 445 11 63

Kat.nr. GN 3410.605 3410.608 3410.805 3410.808

DN 65 65 80 80

d1 65 65 80 80

d2 G 1 ½ G 1 ½ G2 G2

d3 185 185 200 200

h1 82 82 92 92

h2 121 121 127 127

h3 145 145 155 155

l 290 290 310 310

l1 l2 112 4 112 4 124 8 124 8

ºC 40 55 40 55

Tilbakeslagsventil NRF 554 49 84 554 49 86

Kat.nr. GN DN 1650.065 65 1650.080 80

l 240 260

d1 185 200

d2 G1/2 G1/2

Termometer NRF

Kat.nr. GN DN 8349.080 ¼

d 36

l1 16

l2 47

d1 ?

d 40

d1 R ¼

h 38

h1 bar 12 0-12

l1 25

l2 6

Manometer NRF

Kat.nr. GN 8107.081 ¼

DN 8

Kupling NRF Kat.nr. GN DN d1 d2 445 12 63 8201.240 R 1/2" G 3/4"

Kuplingspakning

10

NRF 445 12 03 445 12 06 445 12 09 445 12 13 445 12 16

Kat.nr. GN DN d1 09 294 04 38 09 294 05 44 09 294 09 56 09 294 07 62,5 09 294 10 78

d2 27 35 42 50 65

h 1,5 1,5 1,5 1,5 1,5

d3

O


Ventilprogram

Problemløsing

11


Et ventilhus med mulighet for tre ventiltyper: (1) Tilbakeslagsventil, (2) Skrüseteventil og (3) Skrüseteventil med tilbakeslagssikring. En installert ventil kan gjøres om til en av de andre typene.

NOTAT

12

(2) (1)

(3)


Før installasjon av desinfeksjons løsning Stadig økende problem med legionella infisert tappevann, har satt søkelyset på metoder for fjærning av infeksjonen. Det er i middlertid en del data som må være på plass før metode velges. Metoder Et infisert anlegg må desinfiseres og det kan gjøres på flere måter. Fysisk gjennom: • Termisk desinfeksjon • Membranfiltrering • UV-desinfeksjon m.m. Kjemisk desinfeksjon: • Klorin • Ozon • Diapharagmalyse etc. Før valg av metode er det en del som må kartlegges. Ikke bare kvaliteten på vannet, men type installasjon, materiale i rørledninger, kuplinger, og type/tykkelse på eventuell isolasjon. I tillegg må det tas hensyn til i hvilket miljø anlegget brukes, for eksempel gamlehjem, barnehage, bolig eller idrettshall. Felles for alle desinfeksjonsmetoder er: • Alle koster penger • Ingen metode kan garantere 100% bakteriefritt anlegg • Medfører ekstra belastning på anlegget. Punkter som bør kartlegges: • Annleggets layoyt (finnes f.eks. blindrør?) • Sirkulasjonssystem • Rørdimmensjoner • Rørmateriale • Koblinger/kuplinger • Type isolasjonsmateriale/tykkelse • Varmtvannskilde og kapasitet • Vannkvalitet (kloret?) • Bruksmønster Sjekk også • Temperatur varmt og kaldt vann • plassering og tilstand på varmtvanskilde • Tilstand/vedlikehold av ventiler, koblinger og filtere • Kapasitet og justeringsmuligheter på sirkulasjonspumpe

Forebyggende tiltak • Tilpasse varmtvannskilde • Fjærning av blindrør • Justere rørdimmensjoner • Tilpasse isolasjonstykkelsen på varmt/kaldtvanns rørene • Vurdere separate varmekilder for "fjerntliggende" tappesteder Vurdere metode Termisk desinfeksjon Det må først tas stilling til om desinfeksjon må gjøres kontinuerlig eller i henhold til 3-liter regelen. Uansett må rørene gjennomspyles godt med varmt vann underprosessen. Om det fremdeles finnes blindrør, eller det er fjerntliggende tappesteder, er muligheten ny infisering stor! Andre ting som må tas i betraktning Instalasjonsmateriale: • Galvaniserte rør max 60°C (rustfare) • Tilstand og kapasitet på pakninger og annet tetningsmateriale • Ventiler og kuplingers kapasitet Anleggets layout • Ingen rør med stillestående vann • Rørledninger må ha ekspansjonsmulighet • Mulighet for kabel gjennomføringer i vegg • Varmt og kaldtvannsledninger skal være isolert Sirkulasjon • Valg av rett kapasitet på sirkulasjonspumpe • Kontinuerlig drift av sirkulasjonspumpe Varmtvannskilde • Rett type og kapasitet av kjent merke • Kapasitetsvalg må dekke behov ved kjøring av desinfeksjon Temperaturer ved normal bruk • Temperatur ut fra varmtvannskilde >60°C • Til sirkulasjonstank >50° • Sirkulasjonstemperatur ut/inn for mindre anlegg 1 - 3K, større anlegg 3 - 5K • Varmtvannskilden skal kunne dekke 1times tapping med temperatur >60°C pr dag. Temperatur ved termisk desinfeksjon • Hele anlegget, tank, rørledninger og sirkulasjonsledninger >70°C • Alle tappepunkt må være åpne i minimum 3 minutter ved >70°C • OBS! Stor skoldingsfare ved desinfeksjon av anlegg

Nye anlegg dimmensjoneres selvfølgelig med tanke på desinfeksjonsmetode, det bør dog legges vekt på hvilket miljø anlegget skal brukes i!


Armaturjonsson har vært på markedet siden 1970 og har de siste 15 årene etablert seg som en av de ledende innen rørsystemer for tappevann og varme innendørs. I tillegg har vi et bredt program av proffarmatur som servant- dusjog toalettarmatur til offentlige bygg. Vår tredje produktgruppe, installasjonsmateriell, består av nødvendige detaljer for å gjøre enhver montasje på en rask og effektiv måte. Bedriften er sertifisert i henhold til ISO9001 og miljøstandarden ISO14001. Armaturjonsson har alltid lagt betydelig vekt på kvalitet og utvikling. Det er et klart mål for oss å holde en lederposisjon i markedet. Armaturjonsson skal ikke bare være en stor leverandør, men også en støttespiller for norsk rørleggerbransje. Det betyr at vi både skal tilby det beste av komponenter og systemer, og de beste rådgivere som bransjen kan oppdrive!

Armaturjonsson AS Postboks 39 Økern - 0508 OSLO Ulvenveien 87 - 0581 OSLO Telefon 22 63 17 00 - firmapost@armaturjonsson.no - www.armaturjonsson.no


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.