#X HOOK BAR (BY OTHERS) INSERTED INTO PS=Ø COUPLER @ XX" O.C. BEFORE SECOND POUR (SEE STRUCTURAL) CONCRETE SLAB (SEE STRUCTURAL)
VISQUEEN OR SIM. BOND BREAKER INVERTED PS=Ø MULTI-DIRECTIONAL COUPLER CENTERED IN WALL @ XX" O.C. CONCRETE WALL (SEE STRUCTURAL) #X x X'-X" THREADED BAR
NOTES: 1. THE PS=Ø RELIEF JOINT TO REMAIN OPEN FOR XX DAYS. 2. AFTER THE TIME PERIOD SPECIFIED ABOVE, THE PS=Ø COUPLERS TO BE GROUTED PER MANUFACTURES REQUIREMENTS. 3. SEE PS=Ø MANUFACTURE DATA FOR MORE INFORMATION.
PS=Ø RELIEF JOINT OVER TOP OF WALL