Unit Development - Working Drawings

Page 1

INDEX:

PROJECT:

1.4 UNIT DEVELOPMENT

A00 A01 A02 A03 A04 A05 -

UNIT:

WORKING DRAWINGS CLIENT:

MR & MRS AMANDRO

COVER SHEET & GENERAL NOTES SITE PLAN GROUND FLOOR PLAN FIRST FLOOR PLAN ELEVATIONS SECTION 01

ADDRESS:

13 PARK AVENUE, PRESTON 3072

GENERAL NOTES GN01 DO NOT SCALE PLANS, USE WRITTEN DIMENSIONS ONLY.

GN20 THE BUILDING SHALL ENSURE FOR THE GENERAL WATER TIGHTNESS OF ALL NEW AND EXISTING WORKS.

GN02 THE OWNER, BUILDER, SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS, LEVELS, SETBACKS AND SPECIFICATIONS PRIOR TO COMMENCING ANY WORKS OR ORDERING MATERIALS AND SHALL BE RESPONSIBLE FOR ENSURING THAT ALL BUILDING WORKS CONFORM TO THE BUILDING CODE OF AUSTRALIA, AS CODES (CURRENT EDITIONS), BUILDING REGULATIONS, LOCAL BY-LAWS AND TOWN PLANNING REQUIREMENTS.

GN21 SMOKE ALARMS TO BE PROVIDED AND INSTALLED IN ACCORDANCE WITH AS3786. NEW DWELLINGS AND ADDITIONS WITH SLEEPING ACCOMMODATION TO BE HARD WIRED WITH BATTERY BACK UP.

GN03 ALL WORKS SHALL COMPLY WITH BUT NOT LIMITED TO THE FOLLOWING AUSTRALIAN STANDARDS: AS1288 - GLASS IN BUILDINGS - SELECTION AND INSTALLATION. AS1562 - DESIGN AND INSTALLATION OF SHEET ROOF AND WALL CLADDING. AS1684 - RESIDENTIAL TIMBER FRAMED CONSTRUCTION. AS1860 - INSTALLATION AND PARTICLE BOARD FLOORING. AS2047 - INSTALLATION AND SELECTION OF WINDOWS. AS2049 - ROOF TILES. AS2050 - FIXING OF ROOF TILES. AS2870 - RESIDENTIAL SLABS AND FOOTINGS. AS2904 - DAMP PROOF COURSES AND FLASHINGS. AS3500 - PLUMBING AND DRAINAGE. AS3600 - CONCRETE STRUCTURES AS3660 - PROTECTION OF BUILDINGS FROM SUBTERRANEAN TERMITES AS3700 - MASONRY IN BUILDINGS. AS3740 - WATERPROOFING OF WET AREAS IN RESIDENTIAL BUILDINGS. AS3959 - CONSTRUCTION IN A BUSHFIRE PRONE AREA. AS3786 - SMOKE ALARMS. AS4055 - WIND LOADINGS FOR HOUSING. AS 4100 - STEEL STRUCTURES. GN04 THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANY STRUCTURAL OR CIVIL ENGINEERING COMPUTATIONS AND DRAWINGS. GN05 WHERE REQUIRED TREAT AREA BENEATH FLOOR AGAINST TERMITE INFESTATION IN ACCORDANCE WITH RELEVANT STANDARD. CONTACT THE RELEVANT MUNICIPAL COUNCIL TO DETERMINE IF THE IS MANDATORY. GN06 SAFETY GLASS TO BE USED IN THE FOLLOWING CASES: I) ALL ROOMS - WITHIN 500mm VERTICAL OF THE FLOOR II) BATHROOMS - WITHIN 2000mm OF THE FLOOR III) LAUNDRY - WITHIN 1200mm VERTICAL FROM FLOOR AND/OR WITHIN 300mm HORIZONTAL FROM ALL DOORS. IV) DOORWAY - WITHIN 300mm HORIZONTAL FROM DOORS. SHOWER SCREENS SHALL BE GRADE A SAFETY GLASS. GN07 WINDOW SIZES ARE NOMINAL ONLY, ACTUAL SIZE WILL VARY ACCORDING TO MANUFACTURER. WINDOWS TO BE FLASHED ALL AROUND. GN08 STORM WATER SHALL BE TAKEN TO LEGAL POINT OF DISCHARGE AS ADVISED BE THE MUNICIPAL DRAINAGE ENGINEER. CONTACT THE COUNCIL IF UNSURE OF POINT OF DISCHARGE. GN09 SEWER OR SEPTIC SYSTEM SHALL BE IN ACCORDANCE WITH THE RELEVANT AUTHORITIES REQUIREMENTS GN10 FOOTINGS NOT TO ENCROACH TITLE BOUNDARIES AND EASEMENT LINES. OWNER AND BUILDING TO ENSURE THIS DOES NOT OCCUR. GN11 FOR BUILDINGS IN CLOSE PROXIMITY TO THE BEACH, ENSURE THE ALL STEEL WORK, BRICK CAVITY TIES AND STEEL LINTELS, ETC THAT ARE IMBEDDED OR FIXED INTO MASONRY BE PROTECTED IN ACCORDANCE WITH AS3700 HOT DIPPED GALVANISED. GN12 PROVIDE WALL TIES TO BRICKWORK AT MAXIMUM 600mm CRS IN EACH DIRECTION AND WITHIN 300mm OR ARTICULATION JOINTS. GN13 ALL WET AREAS TO COMPLY WITH AS3740. WALL FINISHES SHALL BE IMPERVIOUS TO A HEIGHT OF 1800mm ABOVE FLOOR LEVEL TO SHOWER ENCLOSURES AND 300mm ABOVE BATHS, BASINS, SINKS AND TROUGHS IF WITHIN 75mm OF THE WALL REFER TO CODE FOR ALL REQUIREMENTS. GN14 SUBFLOOR VENTS ARE TO PROVIDE A RATE OF 7500mm2 CLEAR VENTILATION PER 1000mm RUN OF EXTERNAL WALL AND 2200mm2 CLEAR VENTILATION PER 1000mm RUN OF INTERNAL DWARF WALLS (LOCATED BELOW BEARER).

GN22 WHERE BUILDING IS WITHIN A DESIGNATED BUSH FIRE PRONE AREA COMPLIANCE WITH AS3959 - IS REQUIRED TO A LEVEL OF ATTACK AS CONFIRMED BY THE RELEVANT BUILDING SURVEYOR. GN23 W/C DOORS TO TOILET PANS LOCATED WITHIN 1200mm OF THE DOOR JAMB LIFT OFF HINGES MUST BE FITTING. OTHERWISE THE DOOR MUST SWING OUTWARDS. GN24 TERMITE CERTIFICATE (WHERE REQUIRED) TO BE INSTALLED INSIDE METER BOX PRIOR TO OCCUPANCY PERMIT OR CERTIFICATE OF FINAL INSPECTION ISSUE. GN25 THESE NOTES ARE NEITHER EXHAUSTIVE NOR A SUBSTITUTE FOR REGULATIONS, STATUTORY REQUIREMENTS, BUILDING PRACTICE OR CONTRACTUAL OBLIGATIONS AND UNLESS EXPRESSLY STATED OTHERWISE, ARE PROVIDED ONLY AS GUIDELINES. NO RESPONSIBILITY IS ACCEPTED FOR THEIR USE. GN26 DESIGN GUST WIND SPEED/WIND CLASSIFICATION BUILDING TIE-DOWNS TO BE PROVIDED IN ACCORDANCE WITH AS1684-2006 FOR AN ASSUMED DESIGN GUST WIND SPEED/WIND CLASSIFICATION OF -M/S (SUBJECT TO CONFIRMATION ON SITE BY RELEVANT BUILDING SURVEYOR AT FIRST INSPECTION) REFER TO AS1684 FOR CONSTRUCTION REQUIREMENTS. GN27 THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH THE WRITTEN SPECIFICATIONS, ALL CONSULTANTS DRAWINGS AND SPECIFICATIONS AND ANY DISCREPANCIES SHALL BE REFERRED TO NEW DIMENSION DRAFTING. GN28 THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORK. GN29 WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALING AND LARGE DIMENSIONS SHALL TAKE PREFERENCE OVER SMALL ONES. GN30 ALL DIMENSIONS ARE IN METRES AND/OR MILLIMETRES. GN31 STORMWATER DN. 100mm (MIN) OR AS PER ENGINEERS DESIGN CLASS 6 UPVC STORMWATER LINE LAID TO A MINIMUM GRADE OF 1:100 AND CONNECTED TO THE LEGAL POINT OF STORMWATER DISCHARGE PROVIDE INSPECTION OF OPENINGS TO 9000mm c/c AND AT EACH CHANGE OF DIRECTION THE COVER TO UNDERGROUND STORMWATER DRAINS SHALL NOT BE LESS THAN: - 100mm UNDER SOIL - 50mm UNDER PAVED OR CONCRETE AREAS - 100mm UNDER UNREINFORCED CONCRETE OR PAVED DRIVEWAYS - 75mm UNDER REINFORCED CONCRETE DRIVEWAYS. DRAINAGE NOTES GN32-GN38 GN32 ALL DRAINAGE AND SEWERAGE PIPES ADJACENT TO BUILDING TO BE SETBACK AT A DEPTH THAT WILL NOT AFFECT ANGLE OF REPOSE (45°) TO FOUNDING DEPTH. GN33 SERVICE PIPES AND DRAINAGE PIPE JOINTS TO BE ARTICULATED AT SLAB AND FOOTINGS - WALL PENETRATIONS. BACK FILL TO TRENCHES SHALL BE FULLY COMPACTED. GN34 WHERE SEWERAGE AND WATER PIPES PASS 'THRU' SLAB AND FOOTINGS, PROVIDE SLEEVOR LAGGING AROUND PIPES TO ALLOW RELATIVE MOVEMENT 25mm MINIMUM ALL AROUND. GN35 GRADING AND SITE DRAINAGE - THE AREA WITHIN 2000mm OF BUILDING LINE SHALL BE GRADED SO THAT WATER WILL NOT POND AGAINST BUILDING. GN36 GRADE SHALL BE 50mm WITHIN FIRST METER ON SEVERAL SLOPING SITES ADOPT AG DRAINS ADJACENT TO FOOTINGS WHERE THE GROUND FALLS TOWARDS THE BUILDING. GN37 STORMWATER DRAINAGE DISCHARGE POINT - TO KERB AND CHANNEL LOCATION TO BE DETERMINED ON SITE BY BUILDER, OWNER AND PLUMBER WITH AID OF COUNCIL RECORDS. GN38 ADOPT SEWER GRADE WHEN SUSPENDED UNDER TIMBER FLOOR CLIPPED TO JOIST WITH MINIMUM GRADE.

GN15 PROVIDE CLEARANCE FROM UNDERSIDE OF BEARERS TO FINISHED GROUND LEVEL OF 150mm FOR FLOOR WITH STRIP FLOORING OR 200MM FOR FLOORS WITH PARTICLEBOARD FLOORING AND 400mm IN A TERMITE DECLARED AREA. GN16 DWELLING ADDITIONS PROVIDE THERMAL INSULATION IN ACCORDANCE WITH NCC ENERGY EFFICIENCY REQUIREMENTS NEW DWELLINGS, TO COMPLY WITH 5 STAR ENERGY RATING REPORT (H.E.R.S.). GN17 STAIR REQUIREMENTS RISERS - 190mm MAXIMUM - 115mm MINIMUM. GOING - 355mm MAXIMUM - 240mm MINIMUM. (DOMESTIC ONLY) RISERS AND TREADS TO BE CONSTANT IN SIZE THROUGHOUT FLIGHT. PROVIDE NON-SLIP FINISH OR SUITABLE NON-SKID STRIP NEAR EDGE OF NOSINGS AND LANDINGS. MAXIMUM GAP TO OPEN TREAD NOT TO EXCEED 125mm FOR WIRE BALUSTRADE SEE NCC VOLUME 2 REQUIREMENTS. GN18 STUMPS EXCEEDING 1200mm ABOVE GROUND TO BE BRACED CONCRETE STUMPS - 100mm2 UP TO 1400mm LONG (No. 1 WIRE) - 100mm2 1400mm TO 1800mm LONG (No. 2 HD. WIRES) -125mm2 1800mm TO 3000mm LONG (No. 2 HD. WIRES) GN19 THE BUILDER SHALL TAKE ALL STEPS NECESSARY TO ENSURE STABILITY OF NEW AND EXISTING STRUCTURES DURING ALL WORKS.

GSEducationalVersion GSPublisherVersion 0.1.100.88

PROJECT :

DRAWN BY NICHOLAS J. POTTER

1.4 UNIT DEVELOPMENT WORKING DRAWING

CHECKED BY NJP

13 PARK AVENUE

CLIENT

PRESTON VICTORIA 3072

MR & MRS AMANDRO

SCALE :

DATE :

20/06/2016

DRAWING TITLE : COVER SHEET

DWG No

A00


ROAD

SITE ANALYSIS: SITE AREA: TOTAL FLOOR AREA: UNIT 1 TOTAL FLOOR AREA: UNIT 2 TOTAL FLOOR AREA: SITE COVERAGE: PRIVATE OPEN SPACE: PERMEABILITY:

EXTERNAL WALL ELECTRICITY POLE TELEPHONE PIT SEWER INSPECTION SHAFT WATER METER GAS METER SW

STORM WATRER

S

SEWAGE

1. 100x75mm DOWNPIPES WITH Ø100mm SW PIPE BELOW GRADE @ MIN. 1:100 FALL TO COMPLY WITH AS/NZS 3500/3.

CROSSING

2. CONNECT ALL DOWNPIPES TO LEGAL POINT OF DISCAHRGE. LOCATION TO BE CONFIRMED ON SITE BY BUILDER/PLUMBER & WITH THE AID OF COUNCIL RECORDS.

GARAGE

BRICK (0.6m HIGH)

CHANNEL AND

PATH 77

.8

0

9200

No 10A SINGLE STOREY BRICK DWELLING COMBINATION OF HIP AND VALLEY AND GABLE TILED ROOF 3 LAWN

.0

CONCRETE

CONCRETE

LAWN

6000

84

KERB CONCRETE

BITUMEN ROAD

SINGLE STOREY BRICK DWELLING COMBINATION OF HIP AND VALLEY AND GABLE TILED ROOF

CROSSING

CARPORT

8600

CONCRETE

PORCH

GARAGE WEATHERBOARD

LAWN

PICKET (1.3m HIGH)

WINDOWS NOT VISIBLE ACCESS REQUIRED

SCREENING

LAWN

No 11

No 12

S

SCREENING

WEATHERBOARD SINGLE STOREY DWELLING COMBINATION OF HIP AND VALLEY AND GABLE TILED ROOF

LAWN

CROSSING

2 .3 78

1500

FIBRO WALL

AND

3600

8110

PORCH

LAWN

KERB

DP

DP

PAVED DRIVEWAY

CONCRETE CROSSING

22.5°

22.5°

BOUNDARY 50.60 275°55'50"

CHANNEL

22.5°

DP

DP

.5 22

22.5°

BOUNDARY 13.72 185° 53' 50"

UNIT 1

22.5°

LAWN

LANDSCAPED GARDEN

22.5°

WALL 1.2m HIGH

°

PAVING

.5 22

DP

22.5°

D P

22.5°

22.5°

DP

22.5°

°

PROPOSED RESIDENCE 22.5° No 13 °

22.5°

VERANDAH

22.5° LAWN

PAVING

DP

22.5°

22.5°

(4m HIGH)

22.5°

22.5°

2020

DRIVEWAY

. 22

UNIT 2

1430

22.5°

PROPOSED RESIDENCE 22.5° No 13 5° 22.5° 22.5°

BITUMEN

STREET

°

22.5°

.5 22

°

FORD

.5 22

22.5°

.5 22

BOUNDARY 13.72 5° 53' 50"

22.5°

CARPORT

LAWN

DP

DP

CARPORT

22.5°

AVENUE

7 .8

2200 LAWN

77

SW

DP

LAWN

SHED

DRYING AREA

2500

DRYING AREA

DP

SHED

BOUNDARY 50.60 95° 55' 50"

PARK

DP

78

.8

95° 55' 50"

3000

2200

3

7600

E

LAWN

PORCH

BRICK UNITS FLUSH GABLE TILED ROOF

BRICK UNITS

DOWNPIPE

NOTE:

LAWN

BRICK & STONE (0.8m HIGH)

SINGLE STOREY

PATH

No 15

DOUBLE STOREY

CONCRETE

BRICK (0.8m HIGH)

CONCRETE CROSSING

DP

DG

VACANT

U/G SW PIPE

RI

No 17

LAWN

694.23 m2 438.6 m2 235.9 m2 208.4 m2 296.8 m2 (42.8%) 176.6 m2 201.1 m2 (29.0%)

LEGEND

APPROX. 100.74m TO MURRAY ROAD

WELD MESH (1.2m HIGH)

CROSSING

MURRAY

SITE PLAN 1:200

GSEducationalVersion GSPublisherVersion 0.1.100.88

PROJECT :

DRAWN BY NICHOLAS J. POTTER

1.4 UNIT DEVELOPMENT WORKING DRAWING

CHECKED BY NJP

13 PARK AVENUE

CLIENT

PRESTON VICTORIA 3072

MR & MRS AMANDRO

SCALE :

1:200

DATE :

20/06/2016

DRAWING TITLE : SITE PLAN

DWG No

A01


22020

6160

265

5485

110

90

2630

665

1200

4200

1200

1040

900

90

240

1910

790

5800

900

240

785

4000

240

5320

885

1500

1020

1500

975

2495

1095

1 2

VOID ABOVE

920

300

4

5

6

7

8

9

10

11

13

PTY

14

3 15

90

D01 SM

150

90

F

G G

POR.

3270

560 150

150

110

5640

2500 240

5750

1500

7070

3200

2150

500 4101

90

90 8270

240

10120

1200

AJ PERGOLA ALL F17 TIMBER RAFTERS x 12 - 140 x 45, 2025 LONG EDGE/SIDE BEAM - 140 x 45. 4600 LONG POST x 4 - 120 x 90, 3000 TALL DULUX 'RED ROCK' PAINT FINISH 600 670

2110

240

300

W02

D P

300

W03

S01 A05

1440

WM WM

DB

4260

1500

5640

AJ

UP

D P

D04

1480

2625 NOTE 2

240

1130

1240

125

12

820

AJ

990

5160

920

4050

DW

125

RANGE HOOD ABOVE STOVE

5000

3800

1490 240

TILE

PAVING STONE

W01

500

D P

460

1990

240

450

450 960

240

KITCHEN

1950

W04

LIVING

1110

D P

600

960 240

750

W10

FFB

FFB

W05

350

450

90

MEALS

700

820

AJ

W09

2800

100

AJ

W08

PAVING STONE

2241

S

D05

D P

1200

POR.

D06

D P

260

TILE

1600

800

2880

STUDY

D02

CPT 300

110 1960

CONC 3.5 x 6.5

240

2200

90

2720

10120

W

GARAGE

330 900

TILE

WC

715

D07

820

LAUNDRY

W07

820

D P

570

D08

1800

2250

150

CONC

500

GARAGE

AJ

820

6500

TILE 2.5 x 2.1

6720

LAUNDRY

HW

AJ

S01 A05

WALL (1.2m HIGH)

CL

D03

W06

AJ

800

800

1580

SHED

AJ

AJ

SITE BOUNDARY 50.6m 95° 55' 50"

TIMBER PAILING FENCE (1.8m HIGH)

D P

D P

110

AJ

600 750

3720 90

900

500

1360

240

240 6400

1600

22020

LEGEND: SM DB

GROUND FLOOR PLAN 1:100 UNIT 1

NOTE:

SMART METER POWER DISTRIBUTION BOARD GAS METER

HW

HOT WATER SERVICE

D P

G

DOWNPIPE

1.

REFER TO WINDOW & DOOR SCHEDULE.

2.

90° WINDER STAIRS, TREAD 15 x 255 (50mm NOSING), 16 x 189 RISER, TOTAL RISE 3040, REFER NCC 3.9.1.

3.

LOCATION OF DOWNPIPES & AJs ARE INDICATIVE ONLY AND MAY BE CHANGED AT BUILDERS DISCRETION.

EXHAUST FAN WM

WATER METER AJ S

ARTICULATION JOINTS SMOKE DETECTOR ROOF LINE WALL LINE ABOVE

GSEducationalVersion GSPublisherVersion 0.1.100.88

PROJECT :

DRAWN BY NICHOLAS J. POTTER

1.4 UNIT DEVELOPMENT WORKING DRAWING

CHECKED BY NJP

13 PARK AVENUE

CLIENT

PRESTON VICTORIA 3072

MR & MRS AMANDRO

SCALE :

1:100

DATE :

20/06/2016

DRAWING TITLE : GROUND FLOOR PLAN UNIT 1

DWG No

A02


13920

1350

900

1610

1850

90

600

4140

SITE BOUNDARY 50.6m 95° 55' 50"

D P

TIMBER FENCE FENCE (1.8m HIGH)

S01 A05

955

955

90 6

7

8

9

10

11

12

13

W14

D P

240

14

16

S 15

190

90

D P

700

450

NOTE 4

D P

90 360

600

240

W18

W19

E

NOTE 2

W17

W16

620

900

4580

800

800

5610

150

WALL RIDGE, BOXED OUT 150 x 350

S01 A05

900

4100

W15

3270

TIMBER FENCE FENCE (1.8m HIGH)

90

690

BIR

1090

900

D09

2350

240

90

CPT

1200 530

W13

1200

HALL

LIN

WIR

D15

CPT

1330

600

90

D14

BED 1

820 1560

2070 90 MH

1500

910

820 S

100

960

260

1960 D P

140

W12

D P

720

CPT

D10

TILE

D11

D12

820

720 100

BED 2

ENS

TILE

600

2960 90 3290

6520

D13 7120

BATH

CPT

490

BED 3

WIR

W23

4

D P

90

W22

4995

2050

W21

CARPORT

255

90

3870

7120

600

90

2800

460

90

3500

1050

90

1450

3960

5

240

4590

90 370 90

5370

2800

600

750

200 90

4070

3270

6070

90

90 3810

240

5950

13919

NOTE: 1.

REFER TO WINDOW & DOOR SCHEDULE.

2.

90° WINDER STAIRS, TREAD 15 x 255 (50mm NOSING), 16 x 189 RISER, TOTAL RISE 3040, REFER NCC 3.9.1.

3.

LOCATION OF DOWNPIPES IS INDICATIVE ONLY AND MAY BE CHANGED AT BUILDERS DISCRETION.

4.

ALL FIRST FLOOR EAVES 450mm.

FIRST FLOOR PLAN 1:100 UNIT 1

D P

LEGEND: DOWNPIPE EXHAUST FAN E

MAINS POWER CONNECTION

S

SMOKE DETECTOR

MH

MANHOLE ROOFLINE

GSEducationalVersion GSPublisherVersion 0.1.100.88

PROJECT :

DRAWN BY NICHOLAS J. POTTER

1.4 UNIT DEVELOPMENT WORKING DRAWING

CHECKED BY NJP

13 PARK AVENUE

CLIENT

PRESTON VICTORIA 3072

MR & MRS AMANDRO

SCALE :

1:100

DATE :

20/06/2016

DRAWING TITLE : FIRST FLOOR PLAN

DWG No

A03


STEEL SHEET ROOF, LYSAGHT CUSTOM ORB ACCENT 21, BMT 0.48mm @ 22.5° PITCH, COLORBOND 'SURFMIST' FINISH.

UNIT 1 CL

FL

W19

R.L. 81.47 R.L. 81.17

F.

F.

O.

O.

O.

O.

O.

W18

W17

W16

F.

WEATHERBOARD CLADDING, JAMES HARDIE PRIMELINE NEWPORT, DUELUX 'SURFMIST' PAINT FINISH.

F.

R.L. 78.47

GL

R.L. 78.32

O.

W05

O.

3550

6880

3200

O.

D01

W03

FIBRE CEMENT CLADDING BGC, DULUX 'NATURAL WHITE' PAINT FINISH. DOWNPIPES, LYSAGHT RECTANGULAR, BMT 0.40mm 100 x 75mm COLORBOND 'SURFMIST' FINISH. PERGOLA, REFER NOTE 1.

F.

650

POWER DISTRIBUTION BOARD

W02

W04

1140

FL

O.

3590

3395

2700

CL

150

W15

SOFIT LINING DULUX 'NATURAL WHITE' PAINT FINISH. FASCIA, LYSAFHT NOVALINE COLORBOND 'BASALT' FINISH. GUTTER , LYSAGHT TRIMLINE COLORBOND 'BASALT' FINISH.

4000

O.

302

6850 6832

2445

R.L. 83.92

8.5°

D02 AJ

AJ

AJ

GLAZED BRICK, OSCAR (RED) BY PGH BRICKS & PAVERS. STACK BOND CONFIGURATION WITH WHITE MORTAR.

SOUTH ELEVATION 1:100

RED PRESSED BRICKS WITH 9mm CEMENT RENDER, BY TMC 'CHARCOAL' COLOUR TINT

STEEL SHEET ROOF, LYSAGHT CUSTOM ORB ACCENT 21, BMT 0.48mm @ 22.5° PITCH, COLORBOND 'SURFMIST' FINISH.

RIDGE

UNIT 1 CL

SOFIT LINING DULUX 'NATURAL WHITE' PAINT FINISH. FASCIA, LYSAFHT NOVALINE COLORBOND 'BASALT' FINISH. GUTTER , LYSAGHT TRIMLINE COLORBOND 'BASALT' FINISH.

O.

W23

W22

O.

O.

DOWNPIPES, LYSAGHT RECTANGULAR, BMT 0.40mm 100 x 75mm COLORBOND 'SURFMIST' FINISH.

F.

F.

WEATHERBOARD CLADDING, JAMES HARDIE PRIMELINE NEWPORT, DUELUX 'SURFMIST' PAINT FINISH.

W20

W21

6850

O.

R.L. 81.47 R.L. 81.17

302

6880

2445

R.L. 83.92

FL

TITLE

N.G.L. AJ

FL

R.L. 78.47

GL

R.L. 78.32 N.G.L.

O.

O.

O.

O. W10

W09

O.

O. O.

3200

O.

3490

O.

F.

W08

W07

D03

W06

8.5° TITLE

150

2700

4000

PERGOLA, REFER NOTE 1.

3590

CL

AJ

AJ

AJ

AJ RED PRESSED BRICKS WITH 9mm CEMENT RENDER, BY TMC 'CHARCOAL' COLOUR TINT

NORTH ELEVATION 1:100

DOWNPIPES, LYSAGHT RECTANGULAR, BMT 0.40mm 100 x 75mm COLORBOND 'SURFMIST' FINISH. SOFIT LINING DULUX 'NATURAL WHITE' PAINT FINISH. FASCIA, LYSAFHT NOVALINE COLORBOND 'BASALT' FINISH. GUTTER , LYSAGHT TRIMLINE COLORBOND 'BASALT' FINISH. STEEL SHEET ROOF, LYSAGHT CUSTOM ORB ACCENT 21, BMT 0.48mm @ 22.5° PITCH, COLORBOND 'SURFMIST' FINISH.

RIDGE

SOFIT LINING DULUX 'NATURAL WHITE' PAINT FINISH. FASCIA, LYSAFHT NOVALINE COLORBOND 'BASALT' FINISH. GUTTER , LYSAGHT TRIMLINE COLORBOND 'BASALT' FINISH.

UNIT 1

CL

W13

O.

WEATHERBOARD CLADDING, JAMES HARDIE PRIMELINE NEWPORT, DUELUX 'SURFMIST' PAINT FINISH.

W12

FL

R.L. 81.47 R.L. 81.17

CL

FL

R.L. 81.47 R.L. 81.17

AJ

FL

R.L. 78.32

GL

R.L. 78.47 NGL

TITLE

R.L. 78.47

TITLE

N.G.L.

2700

3490

F. TITLE

TITLE

O.

150

O.

FL

4000

2700

W01

3200

CL

PERGOLA, REFER NOTE 1.

150

6880

O.

2445

O.

302

2445

O.

W14

302

6880

R.L. 83.92

DOWNPIPES, LYSAGHT RECTANGULAR, BMT 0.40mm 100 x 75mm COLORBOND 'SURFMIST' FINISH.

F.

GL

CL

R.L. 83.92

F.

F.

STEEL SHEET ROOF, LYSAGHT CUSTOM ORB ACCENT 21, BMT 0.48mm @ 22.5° PITCH, COLORBOND 'SURFMIST' FINISH.

R.L. 78.32

RED PRESSED BRICKS WITH 9mm CEMENT RENDER, BY TMC 'CHARCOAL' COLOUR TINT GLAZED BRICK, OSCAR (RED) BY PGH BRICKS & PAVERS. STACK BOND CONFIGURATION WITH WHITE MORTAR.

EAST ELEVATION 1:100 NOTE: 1.

GSEducationalVersion GSPublisherVersion 0.1.100.88

PERGOLA - ALL F17 TIMBER - RAFTERS x 12 - 140x45, 2025 LONG - EDGE/SIDE BEAM - 140x45. 4600 LONG - POST x 4 - 120x90, 3000 TALL - DULUX 'RED ROCK' PAINT FINISH

FIBRE CEMENT CLADDING BGC, DULUX 'NATURAL WHITE' PAINT FINISH.

WEST ELEVATION 1:100 PROJECT :

DRAWN BY NICHOLAS J. POTTER

1.4 UNIT DEVELOPMENT WORKING DRAWING

CHECKED BY NJP

13 PARK AVENUE

CLIENT

PRESTON VICTORIA 3072

MR & MRS AMANDRO

SCALE :

1:100

DATE :

20/06/2016

DRAWING TITLE : ELEVATIONS

DWG No

A04


SOFIT LINING 6mm FC SHEETING, DULUX 'NATURAL WHITE' PAINT FINISH. FASCIA LYSAFHT NOVALINE COLORBOND 'BASALT' FINISH. GUTTER , LYSAGHT TRIMLINE COLORBOND 'BASALT' FINISH. STEEL SHEET ROOF, LYSAGHT CUSTOM ORB ACCENT 21, BMT 0.48mm @ 22.5° PITCH, COLORBOND 'SURFMIST' FINISH. ROOF BATTENS 70x35 MGP10 1500mm MAX END SPAN AND 1900mm MAX INTERNAL SPAN WITH REFLECTIVE FOIL SARKING ON ROOF TRUSS 110 x 45 MGP10 @ 600 CTRS. STEEL SHEET ROOF, LYSAGHT CUSTOM ORB ACCENT 21, BMT 0.48mm @ 22.5° PITCH, COLORBOND 'SURFMIST' FINISH. RAISED TOP RIDGE FLASHING BY STRATCO, COLORBOND SURFMIST FINISH. ROOF BATTENS 70x35 MGP10 1500mm MAX END SPAN AND 1900mm MAX INTERNAL SPAN WITH REFLECTIVE FOIL SARKING ON ROOF TRUSS 110 x 45 MGP10 @ 600 CTRS. 13mm PLASTERBOARD CEILING LINING, DULUX 'WHISPER WHITE' PAINT FINISH. BULK INSULATION, MR FLUFFY BATS R5.0.

C.L.

SOFIT LINING 6mm FC SHEETING, DULUX 'NATURAL WHITE' PAINT FINISH. FASCIA LYSAFHT NOVALINE COLORBOND 'BASALT' FINISH. GUTTER , LYSAGHT TRIMLINE COLORBOND 'BASALT' FINISH.

R.L. 83.92

F.

2445

APRON FLASHING

WIR O.

O.

O.

302

W12

R.L. 81.52

C.L.

R.L. 81.17

F.

O. F.

W13

3550

W14

6850

F.L.

BED 1

DOUBLE STUD WALL 90 x 45 MGP10 @ 450 CTRS, WITH ENVIROSEAL SARKING, BULK INSULATION, R2.7 KNAUF EARTHWOOL BATS, WEATHERBOARD CLADDING, JAMES HARDIE PRIMELINE NEWPORT, DUELUX 'SURFMIST' PAINT FINISH. 10mm PLASTERBOARD LINING, DULUX 'WHISPER WHITE' PAINT FINISH.

WALL RIDGE 150 x 350 BOXED OUT 90 x 45 MGP10. 6mm CEMENT SHEETING CLADDING, WITH DULUX 'NATURAL WHITE' PAINT FINISH. APRON FLASHING WITH 'OFF WHITE' FINISH BY STRATCO. DOWNPIPE, LYSAGHT RECTANGULAR, BMT 0.40mm 100 x 75mm COLORBOND 'SURFMIST' FINISH.

STAIRWELL W09

13mm PLASTERBOARD CEILING LINING, DULUX 'WHISPER WHITE' PAINT FINISH. 45 x 70 x 302 POSISTRUT BOTTOM CHORD FLOOR TRUSSES SUPPORTED BY 310UB STEEL UNIVERSAL BEAM & CHANNEL (TO ENGINEERS SPECIFICATION), WITH BULK INSULATION, MR FLUFFY BATS R5.0. 19mm YELLOW TONGUE PARTICLE BOARD WITH CARPET UNDERLAY.

11

3910

10 9 8

2700

LIVING

7

10mm PLASTERBOARD LINING DULUX 'WHISPER WHITE' PAINT FINISH. STUD WALL 90 x 45 MGP10 @ 450 CTRS. BULK INSULATION, R2.7 KNAUF EARTHWOOL WALL BATS WITH ENVIROSEAL SARKING. RED PRESSED BRICK CLADDING, CEMENT RENDER BY TMC CHARCOAL COLOUR TINT.

6

W01

5 4 3

F.

G.L.

O.

2

TIMBER FLOATING FLOORBOARDS BY NATURE PLUS, 15mm JARRAH ON 2mm FOAM UNDERLAY.

1

R.L. 78.47 R.L. 78.32 500

150

F.L.

O.

STUD WALL 90 x 45 MGP10 @ 450 CTRS, WITH ENVIROSEAL SARKING, BULK INSULATION, R2.7 KNAUF EARTHWOOL BATS, 10mm PLASTERBOARD LINING, DULUX 'WHISPER WHITE' PAINT FINISH

100mm SLAB ON GROUND RC (DETAILS TO BE CONFIRMED BY ENGINEER)

90° WINDER STAIRS, REINFORCED CONCRETE, 50mm JARRAH TREAD 15 x 255 (50mm NOSING), 16 x 189 RISER, TOTAL RISE 3040, REFER NCC 3.9.1. BALUSTRADE/HANDRAIL, JARRAH.

S01 A02

GSEducationalVersion GSPublisherVersion 0.1.100.88

Section 01 1:50

PROJECT :

DRAWN BY NICHOLAS J. POTTER

1.4 UNIT DEVELOPMENT WORKING DRAWING

CHECKED BY NJP

13 PARK AVENUE

CLIENT

PRESTON VICTORIA 3072

MR & MRS AMANDRO

SCALE :

1:50

DATE :

20/06/2016

DRAWING TITLE : SECTION 01

DWG No

A05