PRODUCT CATALOG
Edition 04/14
RF Components and Accessories
INDEX • Unflanged Elbows
7/8” Male - Male..........................................................................................................2 1+5/8” Male - Male......................................................................................................3 1+5/8” Male - Female..................................................................................................4 1+5/8” Female - Female..............................................................................................5 3+1/8” Male - Male......................................................................................................6
• Flanged Elbows
7/8” .............................................................................................................................8 1+5/8” .........................................................................................................................9 3+1/8” .........................................................................................................................10
• Coaxial Adaptors
7/8” Female – 1+5/8” Male......................................................................................... 12 7/8” Female – 4+1/2” Female......................................................................................13 1+5/8” Female – N Female..........................................................................................14 1+5/8” Female – 7/16” Female................................................................................... 15 1+5/8” Female – 7/8” Female..................................................................................... 16 1+5/8” Female – 4+1/2” Female................................................................................. 17 3+1/8” Female – “N” Female...................................................................................... 18 3+1/8” Female – 7/16” Female................................................................................... 19 3+1/8” Female – 7/8” Female..................................................................................... 20 3+1/8” Female – 1+5/8” Female................................................................................. 21 3+1/8” Female – 4+1/2” Female................................................................................. 22 4+1/2” Female – 6+1/8” Female................................................................................. 23
• Inners
7/8”............................................................................................................................. 25 1+5/8”......................................................................................................................... 26 3+1/8”......................................................................................................................... 27 4+1/2”......................................................................................................................... 28
• Coaxial Rigid Lines
7/8”..............................................................................................................................30 1+5/8”......................................................................................................................... 31 3+1/8”.........................................................................................................................32
• Centring for Rigid Lines
7/8”.............................................................................................................................34 1+5/8”.........................................................................................................................35 3+1/8”.........................................................................................................................36 4+1/2”.........................................................................................................................37
• Flanges
7/8” .............................................................................................................................39 1+5/8” ........................................................................................................................ 40 3+1/8” ........................................................................................................................ 41 4+1/2” ....................................................................................................................... 42 Specifications are subject to change without prior notice
RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
II
• Directional Coupler
1+5/8” (2 probes)........................................................................................................ 44 3+1/8” (2 probes)........................................................................................................ 46 4+1/2” (2 probes)........................................................................................................ 49
• Accessories for Directional Couplers
Digital Power Meter FM ..............................................................................................51 Digital Power Meter TV .............................................................................................. 52 Digital Power Meter FM with panel ............................................................................ 53 Digital Power Meter TV with panel ............................................................................ 54
• Dummy Load
150W ..........................................................................................................................56 250W ..........................................................................................................................57 5 KW FM air cooled ................................................................................................... 58
• Coaxial Switching Relay
2-Way Coaxial Switching Relay, EIA 1+5/8” connectors.............................................61
• Accessories for Coaxial Switching Relay
Control Panel for coaxial relay.................................................................................... 64 Fast by-pass Patch panel 1+5/8” ............................................................................... 65
• Flanges to weld
7/8”.............................................................................................................................69 1+5/8”......................................................................................................................... 70 3+1/8”......................................................................................................................... 71 4+1/2”......................................................................................................................... 72
• Connectors for RF Cable
7/8” EIA Flange for 1/2” foam cable............................................................................ 74 7/8” EIA Flange (90°) for 1/2” foam cable................................................................... 75 7/8” EIA Flange for 7/8” foam cable............................................................................ 76 1+5/8” EIA Flange for 1”+5/8 foam cable....................................................................77
• Straight Adaptors
3+1/8” Straight Adaptors (Coupling assembly with inner)........................................... 79
• U-Link
7/8” .............................................................................................................................81 1+5/8” .........................................................................................................................82 3+1/8” .........................................................................................................................83 4+1/2” .........................................................................................................................84
• Patch Panels
7/8” six ports / three U-Links ...................................................................................... 86 1+5/8” four ports / two U-Links ...................................................................................87 1+5/8” five ports / two U-Links ................................................................................... 88 1+5/8” six ports / three U-Links ..................................................................................89 3+1/8” four ports / two U-Links ...................................................................................90 3+1/8” eight ports / four U-Links ................................................................................ 91 4+1/2” four ports / two U-Links ...................................................................................92 Specifications are subject to change without prior notice
RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
III
Unflanged Elbows
Unflanged Elbow 7/8” (male - male)
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
ADP7878RLAMM 0.1 ÷ 900 Mhz EIA 7/8” 50 Ω
Average power VHF Average power UHF Return Loss Operating Temperature Range Corps / Treatment Inner / Treatment
≤ 5 kW ≤ 2.6 kW ≥ 32dB -40 ÷ +70° C Aluminum / Alodine
Phosphor Bronze / Silver plated
57,70
PTFE ~ 0.11 Kg
49
Insulator Weight
49
25
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
2
Unflanged Elbow 1+5/8” (male - male)
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
ADP5858RLAMM 0.1 ÷ 900 Mhz EIA 1+5/8” 50 Ω
Average power VHF Average power UHF Return Loss Operating Temperature Range
≤ 13 kW ≤ 7 kW ≥ 32dB -40 ÷ +70° C
Corps / Treatment Inner / Treatment
Aluminum / Alodine
Phosphor Bronze / Silver plated
92,30
PTFE ~ 0.62 Kg
80
Insulator Weight
50
80
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
3
Unflanged Elbow 1+5/8” (male - famale)
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
ADP5858RLAMF 0.1 ÷ 900 Mhz EIA 1+5/8” 50 Ω
Average power VHF Average power UHF Return Loss Operating Temperature Range Corps / Treatment Inner / Treatment
≤ 13 kW ≤ 7 kW ≥ 32dB -40 ÷ +70° C Aluminum / Alodine
Phosphor Bronze / Silver plated
87,3
PTFE ~ 0.62 Kg
80
Insulator Weight
50
80 92,30
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
4
Unflanged Elbow 1+5/8” (famale - famale)
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
ADP5858RLAFF 0.1 ÷ 900 Mhz EIA 1+5/8” 50 Ω
Average power VHF Average power UHF Return Loss Operating Temperature Range Corps / Treatment Inner / Treatment
≤ 13 kW ≤ 7 kW ≥ 32dB -40 ÷ +70° C Aluminum / Alodine
Phosphor Bronze / Silver plated
96,30
PTFE ~ 0.62 Kg
80
Insulator Weight
50
80
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
5
Unflanged Elbow 3+1/8” (male - male)
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
ADP318318RLA 0.1 ÷ 900 Mhz EIA 3+1/8” 50 Ω
Average power VHF Average power UHF Return Loss Operating Temperature Range
≤ 35 kW ≤ 22 kW ≥ 32dB -40 ÷ +70° C
Corps / Treatment Inner / Treatment
Aluminum / Alodine
Phosphor Bronze / Silver plated PTFE ~ 1.54 Kg
120
Insulator Weight
87
126
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
6
Flanged Elbows
Flanged Elbow 7/8”
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
ADP88 0.1 ÷ 900 Mhz EIA 7/8” 50 Ω
Average power VHF Average power UHF Return Loss Operating Temperature Range
≤ 5 kW ≤ 2.6 kW ≥ 32dB -40 ÷ +70° C
Flange / Treatment Corps / Treatment Inner / Treatment Insulator Weight
Brass / Nickel plating Brass / Nickel plating Brass / Silver plated PTFE ~ 0.47 Kg
57,20
7
54,88 70,48
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
8
Flanged Elbow 1+5/8”
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
ADP158158 0.1 ÷ 900 Mhz EIA 1+5/8” 50 Ω
Average power VHF Average power UHF Return Loss Operating Temperature Range
≤ 13 kW ≤ 7 kW ≥ 32dB -40 ÷ +70° C
Flange / Treatment Corps / Treatment Inner / Treatment Insulator Weight
Brass / Nickel plating Aluminum / Alodine Brass / Silver plated PTFE ~ 1.12 Kg
89
0
8,5
M8
96,70 116,20
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
9
Flanged Elbow 3+1/8”
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
ADP318318 0.1 ÷ 900 Mhz EIA 3+1/8” 50 Ω
Average power VHF Average power UHF Return Loss Operating Temperature Range
≤ 35 kW ≤ 22 kW ≥ 32dB -40 ÷ +70° C
Flange / Treatment Corps / Treatment Inner / Treatment Insulator Weight
Bronze / Nickel plating Aluminum / Alodine Brass / Silver plated PTFE ~ 2.30 Kg
M10
10
,8 0
128
130 151,50 Specifications are subject to change without prior notice
RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
10
Coaxial Adaptors
Coaxials Adaptors 7/8” female - 1+5/8” male
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
ADP78RL158 0.1 ÷ 900 Mhz EIA 7/8” - EIA 1+5/8” 50 Ω
Average power VHF Average power UHF Return Loss Operating Temperature Range Flange / Treatment Corps / Treatment Inner / Treatment
≤ 5 kW ≤ 2.6 kW ≥ 32dB -40 ÷ +70° C Brass / Nickel plating Brass / Nickel plating
Phosphor Bronze / Silver plated
Insulator Weight
PTFE ~ 0.36 Kg
58
M6
7
62,50
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
12
Coaxials Adaptors 7/8” female - 4+1/2” female
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
ADP41278C 0.1 ÷ 900 Mhz EIA 7/8” - EIA 4+1/2” 50 Ω
Average power VHF Average power UHF Return Loss Operating Temperature Range
≤ 5 kW ≤ 2.6 kW ≥ 32dB -40 ÷ +70° C
Flange / Treatment Corps / Treatment Inner / Treatment Insulator Weight
Brass - Bronze / Nickel plating Aluminium / Alodine Brass / Silver plated PTFE ~ 3.37 Kg 160 58
M6
7 11
M1
0 135
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
13
Coaxials Adaptors 1+5/8” female - N female
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
ADP158NF 0.1 ÷ 900 Mhz EIA 1+5/8” - N 50 Ω
Average power VHF Average power UHF Return Loss Operating Temperature Range
≤ 500 W ≤ 300 W ≥ 32dB -40 ÷ +70° C
Flange / Treatment Corps / Treatment Inner / Treatment Insulator Weight
Brass / Nickel plating Brass / Nickel plating Brass / Silver plated PTFE ~ 1.52 Kg
8,50
60
M8
101
89
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
14
Coaxials Adaptors 1+5/8” female - 7/16” female
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
ADP15816F 0.1 ÷ 900 Mhz EIA 1+5/8” - DIN 7/16” 50 Ω
Average power VHF Average power UHF Return Loss Operating Temperature Range
≤ 2 kW ≤ 1.2 kW ≥ 32dB -40 ÷ +70° C
Flange / Treatment Corps / Treatment Inner / Treatment Insulator Weight
Brass / Nickel plating Brass / Nickel plating Brass / Silver plated PTFE ~ 1.55 Kg
M8
8,5 60
0
107,50
89
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
15
Coaxials Adaptors 1+5/8” female - 7/8” female
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
ADP1588C 0.1 ÷ 900 Mhz EIA 1+5/8” - EIA 7/8” 50 Ω
Average power VHF Average power UHF Return Loss Operating Temperature Range
≤ 5 kW ≤ 2.6 kW ≥ 32dB -40 ÷ +70° C
Flange / Treatment Corps / Treatment Inner / Treatment Insulator Weight
Brass / Nickel plating Brass / Nickel plating Brass / Silver plated PTFE ~ 0.96 Kg
89 58 7
M6 0
8,5
M8
95
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
16
Coaxials Adaptors 1+5/8” female - 4+1/2” female
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
ADP412158C 0.1 ÷ 900 Mhz EIA 1+5/8” - EIA 4+1/2” 50 Ω
Average power VHF Average power UHF Return Loss Operating Temperature Range
≤ 13 kW ≤ 7 kW ≥ 32dB -40 ÷ +70° C
Flange / Treatment Corps / Treatment Inner / Treatment Insulator Weight
Brass - Bronze / Nickel plating Aluminium / Alodine Brass / Silver plated PTFE ~ 2.01 Kg 160
120
89
M8
M10
8,50
11 Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
17
Coaxials Adaptors 3+1/8” female - N female
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
ADP318NF 0.1 ÷ 900 Mhz EIA 3+1/8” - N 50 Ω
Average power VHF Average power UHF Return Loss Operating Temperature Range
≤ 500 W ≤ 300 W ≥ 32dB -40 ÷ +70° C
Flange / Treatment Corps / Treatment Inner / Treatment Insulator Weight
M10
Bronze / Nickel plating Aluminium / Alodine Brass / Silver plated PTFE ~ 1.5 Kg
,80
89
10
128
119,70
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
18
Coaxials Adaptors 3+1/8” female - 7/16” female
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
ADP318716F 0.1 ÷ 900 Mhz EIA 3+1/8” - DIN 7/16” 50 Ω
Average power VHF Average power UHF Return Loss Operating Temperature Range
≤ 2 kW ≤ 1.2 kW ≥ 32dB -40 ÷ +70° C
Flange / Treatment Corps / Treatment Inner / Treatment Insulator Weight
Bronze / Nickel plating Aluminium / Alodine Brass / Silver plated PTFE ~ 1.3 Kg
M10
,80 89
10
128
116,80
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
19
Coaxials Adaptors 3+1/8” female - 7/8” female
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
ADP31878F 0.1 ÷ 900 Mhz EIA 3+1/8” - EIA 7/8” 50 Ω
Average power VHF Average power UHF Return Loss Operating Temperature Range
≤ 5 kW ≤ 2.6 kW ≥ 32dB -40 ÷ +70° C
Flange / Treatment Corps / Treatment Inner / Treatment Insulator Weight
Bronze - Brass / Nickel plating Aluminium / Alodine Brass / Silver plated PTFE ~ 1.5 Kg
M10
0
10,8
M6
58 128
89
7
136,60
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
20
Coaxials Adaptors 3+1/8” female - 1+5/8” female
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
ADP318158C 0.1 ÷ 900 Mhz EIA 3+1/8” - EIA 1+5/8” 50 Ω
Average power VHF Average power UHF Return Loss Operating Temperature Range
≤ 13 kW ≤ 7 kW ≥ 32dB -40 ÷ +70° C
Flange / Treatment Corps / Treatment Inner / Treatment Insulator Weight
Bronze - Brass / Nickel plating Aluminium / Alodine Brass / Silver plated PTFE ~ 1.4 Kg
M10
0
10,8
8,50
89
86
M8
110,55
128 Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
21
Coaxials Adaptors 3+1/8” female - 4+1/2” female
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
ADP412318C 0.1 ÷ 900 Mhz EIA 3+1/8” - EIA 4+1/2” 50 Ω
Average power VHF Average power UHF Return Loss Operating Temperature Range
≤ 35 kW ≤ 22 kW ≥ 32dB -40 ÷ +70° C
Flange / Treatment Corps / Treatment Inner / Treatment Insulator Weight
Bronze / Nickel plating Aluminium / Alodine Brass / Silver plated PTFE ~ 2.2 Kg
11
M10
10,8
0
114,50
M10
125
128 160
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
22
Coaxials Adaptors 4+1/2” female - 6+1/8” female
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
ADP618412C 0.1 ÷ 900 Mhz EIA 4+1/2” - EIA 6+1/8” 50 Ω
Average power VHF Average power UHF Return Loss Operating Temperature Range
≤ 40 kW ≤ 37 kW ≥ 32dB -40 ÷ +70° C
Flange / Treatment Corps / Treatment Inner / Treatment Insulator Weight
Bronze / Nickel plating Aluminium / Alodine Brass / Silver plated PTFE ~ 3.9 Kg
M10
11 11 161
M10
160
150,70
206,40 Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
23
Inners
Inners 7/8”
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
CNTF8 0.1 ÷ 900 Mhz EIA 7/8” 50 Ω
Average power VHF Average power UHF Return Loss Operating Temperature Range Inner / Treatment
≤ 5 kW ≤ 2.6 kW ≥ 32dB -40 ÷ +70° C
Phosphor Bronze / Silver plated
Insulator Weight
PTFE ~ 0.02 Kg
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
25
Inners 1+5/8”
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
CNT158 0.1 ÷ 900 Mhz EIA 1+5/8” 50 Ω
Average power VHF Average power UHF Return Loss Operating Temperature Range Inner / Treatment
≤ 13 kW ≤ 7 kW ≥ 32dB -40 ÷ +70° C
Phosphor Bronze / Silver plated
Insulator Weight
PTFE ~ 0.06 Kg
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
26
Inners 3+1/8”
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
CNT318 0.1 ÷ 900 Mhz EIA 3+1/8” 50 Ω
Average power VHF Average power UHF Return Loss Operating Temperature Range Inner / Treatment
≤ 35 kW ≤ 22 kW ≥ 32dB -40 ÷ +70° C
Phosphor Bronze / Silver plated
Insulator Weight
PTFE ~ 0.25 Kg
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
27
Inners 4+1/2”
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
CNT412 0.1 ÷ 900 Mhz EIA 4+1/2” 50 Ω
Average power VHF Average power UHF Return Loss Operating Temperature Range Inner / Treatment
≤ 70 kW ≤ 37 kW ≥ 32dB -40 ÷ +70° C
Phosphor Bronze / Silver plated
Insulator Weight
PTFE ~ 0.55 Kg
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
28
Coaxial Rigid Lines
Coaxial Rigid Lines 7/8”
TECHNICAL DATA Part Number Frequency Range Impedance
CCXRL78 DC/1.5 Ghz 50 Ω
Average power VHF Average power UHF Operating Temperature Range
≤ 5 kW ≤ 2.6 kW -40 ÷ +70° C
Inner/Outer conductor Lenght Weight
20
20
22,23
22,23
Polished Copper On request ~ 0.9 Kg/m
7,40
7,40
8,70
8,70
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
30
Coaxial Rigid Lines 1+5/8”
TECHNICAL DATA Part Number Frequency Range Impedance
CCXRL158 DC/1.5 Ghz 50 Ω
Average power VHF Average power UHF Operating Temperature Range
≤ 13 kW ≤ 7 kW -40 ÷ +70° C
Inner/Outer conductor Lenght Weight
Polished Copper On request ~ 2.1 Kg/m
15 16,90 38,80 41,30 Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
31
Coaxial Rigid Lines 3+1/8”
TECHNICAL DATA Part Number Frequency Range Impedance
CCXRL318 DC/1.5 Ghz 50 Ω
Average power VHF Average power UHF Operating Temperature Range
≤ 35 kW ≤ 22 kW -40 ÷ +70° C
Inner/Outer conductor Lenght Weight
Polished Copper On request ~ 4.0 Kg/m
31,30 33,40 76,80 79,40 Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
32
Centering for Rigid Lines
Centering for Rigid Lines 7/8”
TECHNICAL DATA
Part Number Operating Temperature Range
CENISRL78 -40 ÷ +70° C
Material Weight
PTFE ~ 1.3 g
8,60
2,50
19,75
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
34
Centering for Rigid Lines 1+5/8”
TECHNICAL DATA
Part Number Operating Temperature Range
CENISRL158 -40 ÷ +70° C
Material Weight
PTFE ~ 10 g
38,80
6
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
35
Centering for Rigid Lines 3+1/8”
TECHNICAL DATA
Part Number Operating Temperature Range
CENISRL318 -40 ÷ +70° C
Material Weight
PTFE ~ 50 g
76,70
9,50
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
36
Centering for Rigid Lines 4+1/2”
TECHNICAL DATA
Part Number Operating Temperature Range
CENISRL412 -40 ÷ +70° C
Material Weight
PTFE ~ 93 g
103,60
8,90
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
37
Flanges
Flanges 7/8”
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
CNT78FLX78RL 0.1 ÷ 900 Mhz EIA 7/8” 50 Ω
Average power VHF Average power UHF Operating Temperature Range
≤ 5 kW ≤ 2.6 kW -40 ÷ +70° C
Flange / Treatment Corps / Treatment Weight
Brass / Nickel plating Aluminium / Alodine ~ 0.16 Kg
M6
7
26
58
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
39
Flanges 1+5/8”
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
CNT58FLX58RL 0.1 ÷ 900 Mhz EIA 1+5/8” 50 Ω
Average power VHF Average power UHF Operating Temperature Range
≤ 13 kW ≤ 7 kW -40 ÷ +70° C
Flange / Treatment Corps / Treatment Weight
Brass / Nickel plating Aluminium / Alodine ~ 0.43 Kg
M6
0
5 8,
89
32,30
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
40
Flanges 3+1/8”
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
CNT18FLX18RL 0.1 ÷ 900 Mhz EIA 3+1/8” 50 Ω
Average power VHF Average power UHF Operating Temperature Range
≤ 35 kW ≤ 22 kW -40 ÷ +70° C
Flange / Treatment Corps / Treatment Weight
Bronze / Nickel plating Aluminium / Alodine ~ 0.82 Kg
10,8
0
0
M1
128
61,50
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
41
Flanges 4+1/2”
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
CNT41FLX41RL 0.1 ÷ 900 Mhz EIA 4+1/2” 50 Ω
Average power VHF Average power UHF Operating Temperature Range
≤ 70 kW ≤ 37 kW -40 ÷ +70° C
Flange / Treatment Corps / Treatment Weight
Bronze / Nickel plating Bronze / Nickel plating ~ 1.5 Kg
M10
11
160
61,50
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
42
Directional Couplers
Directional Couplers 1+5/8” (2 probes)
TECHNICAL DATA Part Number Frequency Range In/Out connectors Impedance
ACCDIR158DS 10 ÷ 900 Mhz EIA 1+5/8” 50 Ω
Average power VHF Average power UHF Coupling factor Directivity Probe connectors Operating Temperature Range
≤ 13 kW ≤ 7 kW -60dB, other values on request > 30dB N female -40 ÷ +70° C
Flange / Treatment Corps / Treatment Inner / Treatment Probe / Treatment Insulator Weight
Brass / Nickel plating Brass / Nickel plating Copper / Silver plated Brass / Silver plated PTFE ~ 3.2 Kg
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
44
130 235
50
M 8
8, 89
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
45
Directional Couplers 3+1/8” (2 probes)
TECHNICAL DATA Part Number Frequency Range In/Out connectors Impedance
ACCDIR318DS 10 ÷ 900 Mhz EIA 3+1/8” 50 Ω
Average power VHF Average power UHF Coupling factor Directivity Probe connectors Operating Temperature Range
≤ 35 kW ≤ 22 kW -60dB, other values on request > 30dB N female -40 ÷ +70° C
Flange / Treatment Corps / Treatment Inner / Treatment Probe / Treatment Insulator Weight
Bronze / Nickel plating Bronze / Nickel plating Copper / Silver plated Brass / Silver plated PTFE ~ 5.4 Kg
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
46
148 275
10,8
M10
0
128
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
47
Directional Couplers 4+1/2” (2 probes)
TECHNICAL DATA Part Number Frequency Range In/Out connectors Impedance
ACCDIR412DS 10 ÷ 900 Mhz EIA 4+1/2” 50 Ω
Average power VHF Average power UHF Coupling factor Directivity Probe connectors Operating Temperature Range
≤ 70 kW ≤ 37 kW -60dB, other values on request > 30dB N female -40 ÷ +70° C
Flange / Treatment Corps / Treatment Inner / Treatment Probe / Treatment Insulator Weight
Bronze / Nickel plating Bronze / Nickel plating Copper / Silver plated Brass / Silver plated PTFE ~ 6.6 Kg
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
48
148 296
0
M1
11
160
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
49
Accessories for Directional Couplers
Accessories for Directional Couplers Digital Power Meter FM
TECHNICAL DATA Part Number Operating Voltage Consumption
PWRMETER-D1 115-230 Vac 50 ÷ 60 Hz
<5W 85 mm (H) x 200 mm (W) x 167 mm (D)
Dimensions
Forward RF input Connector
BNC
Impedance Input Level / Adjust
50 Ω
10 dBm Reflected RF input
Connector
BNC
Impedance Input Level / Adjust
50 Ω
10 dBm
Relay contact Relay contact Relay contact Full scale RF input (W)
Remote connector outputs 80% FWD 50% FWD 50% RFL
10-20-50-100-200-500-1K-2K-5K-10K20K-50K
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
51
Accessories for Directional Couplers Digital Power Meter TV
TECHNICAL DATA Part Number Operating Voltage Consumption
PWRMETER-D2 115-230 Vac 50 ÷ 60 Hz
<5W 85 mm (H) x 200 mm (W) x 167 mm (D)
Dimensions
Forward RF input Connector
BNC
Impedance Input Level / Adjust
50 Ω
10 dBm Reflected RF input
Connector
BNC
Impedance Input Level / Adjust
50 Ω
10 dBm
Relay contact Relay contact Relay contact Full scale RF input (W)
Remote connector outputs 80% FWD 50% FWD 50% RFL
10-20-50-100-200-500-1K-2K-5K-10K20K-50K
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
52
Accessories for Directional Couplers Digital Power Meter FM with panel
TECHNICAL DATA Part Number Operating Voltage Consumption
PWRMETER-D1P 115-230 Vac 50 ÷ 60 Hz
<5W Standard 3-units rack
Dimensions
Forward RF input Connector
BNC
Impedance Input Level / Adjust
50 Ω
10 dBm Reflected RF input
Connector
BNC
Impedance Input Level / Adjust
50 Ω
10 dBm
Remote connector outputs Relay contact 80% FWD Relay contact 50% FWD Relay contact 50% RFL Full scale RF input (W) 10-20-50-100-200-500-1K-2K-
5K-10K-20K-50K
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
53
Accessories for Directional Couplers Digital Power Meter TV with panel
TECHNICAL DATA Part Number Operating Voltage Consumption
PWRMETER-D2P 115-230 Vac 50 ÷ 60 Hz
<5W Standard 3-units rack
Dimensions
Forward RF input Connector
BNC
Impedance Input Level / Adjust
50 Ω
10 dBm Reflected RF input
Connector
BNC
Impedance Input Level / Adjust
50 Ω
10 dBm
Remote connector outputs Relay contact 80% FWD Relay contact 50% FWD Relay contact 50% RFL Full scale RF input (W) 10-20-50-100-200-500-1K-2K-
5K-10K-20K-50K
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
54
Dummy Load
Dummy Load 150 W
TECHNICAL DATA Part Number Frequency Range Connections Impedance
EDL150-FM DC ÷ 108 Mhz N female 50 Ω 150 W > 27dB Convection -10 ÷ +50° C N.A. 3.3 Kg
120
Max power Return Loss Cooling system Operating Temperature Range Blower AC power Weight
145
132,50
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
56
Dummy Load 250 W
TECHNICAL DATA Part Number Frequency Range Connections Impedance
EDL250-FM DC ÷ 108 Mhz N female 50 Ω 250 W > 27dB Convection -10 ÷ +50° C N.A. 3.3 Kg
120
Max power Return Loss Cooling system Operating Temperature Range Blower AC power Weight
145
132,50
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
57
Dummy Load 5 Kw FM air forced
TECHNICAL DATA Part Number Frequency Range Connections Impedance
EDL5000-FM DC ÷ 108 Mhz EIA 7/8” 50 Ω
Max power Return Loss Cooling system Operating Temperature Range Blower AC power Weight
5 kW > 27dB Air forced -10 ÷ +50° C 110 or 220 V 31 Kg
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
58
135 528
750
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
59
Coaxial Switching Relay
Coaxial Switching Relay 2-Way Coaxial Switching Relay, EIA 1+5/8”
TECHNICAL DATA Part Number Frequency Range Connections Impedance
RLY158-220-24 DC ÷ 1 Ghz EIA 1+5/8” 50 Ω
Average power
≤ 15.0 kW @ 100 MHz ≤ 10.0 kW @ 230 MHz ≤ 5.0 kW @ 860 MHz ≥ 30 dB ≤ 75 dB 230 VAC ± 10%, 50 ÷ 60 Hz 12 ÷ 26 VDC ≤ 0.5 A ≤1s -10 ÷ +50 °C ca. 5.0 kg
Return Loss Isolation Operating Voltage Control Voltage Operating Current Switching Time Ambient Temperature Weight
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
61
145
225
210
212,50
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
62
Accessories for Coaxial Switching Relay
Accessories for Coaxial Switching Relay Control Panel for coaxial relay
TECHNICAL DATA Part Number Operating Voltage Out Control Voltage
KPANCRCP126 115-230 VAC ± 10%, 50 ÷ 60 Hz 12 VDC
Dimensions
Standard 2-units rack
Weight
ca. 1 kg
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
64
Accessories for Coaxial Switching Relay Fast by-pass Patch panel 1+5/8”
This device permits to by-pass the motorized coaxial relay when the electrical control device and the manual control system, are both in failure. You can remove the coaxial relay and use instead of it two manuals links that can be connected in the same ports.
TECHNICAL DATA Part Number Relay connectors U-links numbers
BYPASSRCOAX158 EIA 1+5/8
2
U-links size
EIA 1+5/8”
Dimensions
Standard 8-units rack
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
65
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
66
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
67
Flanges to weld
Flanges to weld 7/8”
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
CNT78FLS78RL 0.1 ÷ 900 Mhz EIA 7/8” 50 Ω
Average power VHF Average power UHF Operating Temperature Range
≤ 5 kW ≤ 2.6 kW -40 ÷ +70° C Brass / Nickel plating Brass / -~ 0.17 Kg
M
6
Flange / Treatment Corps / Treatment Weight
7
58
15
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
69
Flanges to weld 1+5/8”
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
CNT58FLS58RL 0.1 ÷ 900 Mhz EIA 1+5/8” 50 Ω
Average power VHF Average power UHF Operating Temperature Range
≤ 13 kW ≤ 7 kW -40 ÷ +70° C
Flange / Treatment Corps / Treatment Weight
Brass / Nickel plating Brass / -~ 0.44 Kg
M8 8,50
89
18,50
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
70
Flanges to weld 3+1/8”
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
CNT18FLS18RL 0.1 ÷ 900 Mhz EIA 3+1/8” 50 Ω
Average power VHF Average power UHF Operating Temperature Range
≤ 35 kW ≤ 22 kW -40 ÷ +70° C
Flange / Treatment Corps / Treatment Weight
Bronze / Nickel plating Bronze / -~ 0.76 Kg
0
M1
10,8
0
128
17,85
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
71
Flanges to weld 4+1/2”
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
CNT12FLS12RL 0.1 ÷ 900 Mhz EIA 4+1/2” 50 Ω
Average power VHF Average power UHF Operating Temperature Range
≤ 70 kW ≤ 37 kW -40 ÷ +70° C
Flange / Treatment Corps / Treatment Weight
Bronze / Nickel plating Bronze / -~ 1.04 Kg
0
M1
11
160
20
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
72
Connectors for RF Cable
Connectors for RF Cable 7/8” EIA Flange for 1/2” foam cable
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
CNTFL8XCP DC ÷ 5 Ghz EIA 7/8” 50 Ω
Type of cable to use Operating Temperature Range
1/2” Foam (All cable) -40 ÷ +70° C
Flange / Treatment Corps / Treatment Inner / Treatment
Brass / Passivation Brass / Passivation Brass / Silver plated ~ 0.4 Kg
Weight
25,50
23,86
7
80,80
57,20
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
74
Connectors for RF Cable 7/8” EIA Flange (90°) for 1/2” foam cable
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
CNTFL8XCP90 DC ÷ 5 Ghz EIA 7/8” 50 Ω
Type of cable to use Operating Temperature Range
1/2” Foam (All cable) -40 ÷ +70° C
Flange / Treatment Corps / Treatment Inner / Treatment
Brass / Passivation Brass / Passivation Brass / Silver plated ~ 0.5 Kg
Weight
64,05
7
74,89
57,20
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
75
Connectors for RF Cable 7/8” EIA Flange for 7/8” foam cable
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
CNTFL8XC8 DC ÷ 5 Ghz EIA 7/8” 50 Ω
Type of cable to use Operating Temperature Range
7/8” Foam (All cable) -40 ÷ +70° C
Flange / Treatment Corps / Treatment Inner / Treatment
Brass / Passivation Brass / Passivation Brass / Silver plated ~ 0.5 Kg
Weight
34,80
31,70
7
82,90
57,20 Specifications are subject to change without prior notice
RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
76
Connectors for RF Cable 1+5/8” EIA Flange for 1+5/8” foam cable
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
CNT58FLXC58 DC ÷ 5 Ghz EIA 1+5/8” (All cable) 50 Ω
Type of cable to use Operating Temperature Range
1+5/8” Foam -40 ÷ +70° C
Flange / Treatment Corps / Treatment Inner / Treatment
Brass / Passivation Brass / Passivation Brass / Silver plated ~ 1.6 Kg
Weight
59,50
8,50
130
89
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
77
Straight Adaptors
Straight Adaptors 3+1/8” Straight Adaptors (Coupling assembly with inner)
TECHNICAL DATA Part Number Frequency Range Connectors Impedance
ADPGNTRL318 0.1 ÷ 900 Mhz EIA 3+1/8” 50 Ω
Average power VHF Average power UHF Operating Temperature Range
≤ 35 kW ≤ 22 kW -40 ÷ +70° C
Phosphor Bronze / Silver plated
Corps / Treatment Insulator Weight
Aluminium / Alodine PTFE ~ 0.7 Kg
87
Inner / Treatment
92
89 Specifications are subject to change without prior notice
RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
79
U-Link for Patch Panels
U-Link for Patch Panels 7/8”
TECHNICAL DATA Part Number Frequency Range Return Loss Impedance
ULINK78 0.1 ÷ 900 Mhz > 30 dB 50 Ω
Operating Temperature Range Weight
-10 ÷ +50° C ~ 0.35 Kg
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
81
U-Link for Patch Panels 1+5/8”
TECHNICAL DATA Part Number Frequency Range Return Loss Impedance
ULINK158 0.1 ÷ 900 Mhz > 30 dB 50 Ω
Operating Temperature Range Weight
-10 ÷ +50° C ~ 1.3 Kg
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
82
U-Link for Patch Panels 3+1/8”
TECHNICAL DATA Part Number Frequency Range Return Loss Impedance
ULINK318 0.1 ÷ 900 Mhz > 30 dB 50 Ω
Operating Temperature Range Weight
-10 ÷ +50° C ~ 3.5 Kg
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
83
U-Link for Patch Panels 4+1/2”
TECHNICAL DATA Part Number Frequency Range Return Loss Impedance
ULINK412 0.1 ÷ 900 Mhz > 30 dB 50 Ω
Operating Temperature Range Weight
-10 ÷ +50° C ~ 8.2 Kg
Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
84
Patch Panels
Patch Panels 7/8” six ports / three U-Links
TECHNICAL DATA Part Number Connector Ports U-links
PCP6-6-3-78 EIA 7/8” 6 3
Dimensions
Standard 6 unit rack
Other models with different configurations are available on request Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
86
Patch Panels 1+5/8” four ports / two U-Links
TECHNICAL DATA Part Number Connector Ports U-links
PCP6-4-2-58 EIA 1+5/8” 4 2
Dimensions
Standard 6 unit rack
Other models with different configurations are available on request Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
87
Patch Panels 1+5/8” five ports / two U-Links
TECHNICAL DATA Part Number Connector Ports U-links
PCP8-5-2-58 EIA 1+5/8” 5 2
Dimensions
Standard 8 unit rack
Other models with different configurations are available on request Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
88
Patch Panels 1+5/8” six ports / three U-Links
TECHNICAL DATA Part Number Connector Ports U-links
PCP6-6-3-58 EIA 1+5/8” 6 3
Dimensions
Standard 6 unit rack
Other models with different configurations are available on request Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
89
Patch Panels 3+1/8” four ports / two U-Links
TECHNICAL DATA Part Number Connector Ports U-links
PCP7-4-2-318 EIA 3+1/8” 4 2
Dimensions
Standard 7 unit rack
Other models with different configurations are available on request Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
90
Patch Panels 3+1/8” eight ports / four U-Links
TECHNICAL DATA Part Number Connector Ports U-links
PCP15-8-4-318 EIA 3+1/8” 8 4
Dimensions
670 mm (W) x 672 mm (H)
Other models with different configurations are available on request Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
91
Patch Panels 4+1/2” four ports / two U-Links
TECHNICAL DATA Part Number Connector Ports U-links
PCP10-4-2-412 EIA 4+1/2” 4 2
Dimensions
Standard 10 unit rack
Other models with different configurations are available on request Specifications are subject to change without prior notice RVR Elettronica S.p.a. • Phone +39 051 6010506 • Fax +39 051 6011104 • e-mail: info@rvr.it • Web: http://www.rvr.it Telecom Italia S.r.l. • Phone +39 0541 623466 • Fax +39 0541 623467 • e-mail: info@telecomialiasrl.it • Web: http://www.telecomitaliasrl.it
92
RVR Elettronica S.p.a. Via del fonditore, 2/2c Zona Industriale Roveri • 40138 Bologna • Italy Phone: +39 051 6010506 • Fax: +39 051 6011104 E-mail: info@rvr.it • Web: www.rvr.it Telecom Italia s.r.l. Via del Gelso, 2 47822 Santarcangelo di R. (RN) • Italy Phone: +39 0541 623466 • Fax: +39 0541 623467 E-mail: info@telecomitaliasrl.it • Web: www.telecomitaliasrl.it