CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

Page 1

TABLE OF CONTENTS

TITLE PG.1

Prewire documentation

DETAILED INSTRUCTIONS

LEGEND CAT5e Keypad CAT5e Phone CAT5e Network 14/2 Speaker 14/4 Speaker Mon OMC/2C SVRG6 SVRG6 RG6 Quad RGB6C/2CATe RGB3C Mini Component Video HDMI 2 Shielded PR Analog Audio Digital Audio Cresnet Crescat-DC Crescat-Q Romex Conduit (flexible) Conduit (PVC)

1

X-Gang Box

Page 1

Title pg.1

Page 2

004-Bath

Page 3

005-Bath

Page 4

006-Entertainment

Page 5

007-Bar

Page 6

009-Stair

Page 7

101-Entry

Page 8

102-Gallery

Page 9

103-Dining

Page 10

104-Hearth

Page 11

105-Kitchen

Page 12

107-Library

Page 13

108-Hall

Page 14

109-M Bed

Page 15

110-Sitting

Page 16

111-Exercise

Page 17

114-Laundry

Page 18

115-M Bath

Page 19

119-Jeff’s Office

Page 20

122-2 Car

Page 21

124-Powder

Page 22

125-Drop

Page 23

127-Danielle’s Office

Page 24

129-3 Car

Page 25

130-Stair

Page 26

202-Balcony

Page 27

203-Hallway CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

Title pg.1

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

Power Inlet

SHEET:

Power outlet

PW-

1 of38

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


TABLE OF CONTENTS

TITLE PG.2

Prewire documentation

DETAILED INSTRUCTIONS

Page 1

206-Playroom

Page 2

208-Bedroom

Page 3

209-Bedroom

Page 4

210-Bath

Page 5

211-Bath

Page 6

Structured Wiring

Page 7

Wallplates

Page 8

Lighting

Page 9

Climate

Page 10

Shades

LEGEND CAT5e Keypad CAT5e Phone CAT5e Network 14/2 Speaker 14/4 Speaker Mon OMC/2C SVRG6 SVRG6 RG6 Quad RGB6C/2CATe RGB3C Mini Component Video HDMI 2 Shielded PR Analog Audio Digital Audio Cresnet Crescat-DC Crescat-Q Romex Conduit (flexible) Conduit (PVC)

1

X-Gang Box

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

Title pg.2

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

Power Inlet

SHEET:

Power outlet

PW-

2 of38

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


004-Bath

004-BATH DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

CRESNET

CRESNET

1

LIGHTING KEYPAD Location: South wall entry Height: Standard light switch

1

LIGHTING KEYPAD Location: Water closet – west wall entry Height: Standard light switch

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

004-Bath

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-

3 of38

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


005-Bath

005-BATH DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

CRESNET

LIGHTING KEYPAD Location: South wall entry Height: Standard light switch

1

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

005-Bath

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-

4 of38

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


006-Entertainment

006ENTERTAINMENT DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CRESCAT-DC

DM-CBL-NP

AQ HDMI-_ _._M

2

TV Location: West wall Height: TBD

2

TV Location: West wall Height: TBD

2

TV Location: West wall Height: TBD

FRONT LEFT Location: West wall Height: In-wall

S14/2

FRONT CENTER Location: West wall Height: In-wall

S14/2

FRONT RIGHT Location: West wall Height: In-wall

S14/2

REAR LEFT/RIGHT Location: TBD Height: In-ceiling

S14/4

22/2pr

SUBWOOFER Location: West wall Height: In-cabinet

1

LEGEND CAT5e Keypad CAT5e Phone CAT5e Network

SUBWOOFER Location: West wall Height: In-wall

S14/4

14/2 Speaker 14/4 Speaker Mon OMC/2C SVRG6 SVRG6 RG6 Quad RGB6C/2CATe RGB3C Mini Component Video HDMI 2 Shielded PR Analog Audio Digital Audio Cresnet Crescat-DC Crescat-Q Romex Conduit (flexible) Conduit (PVC)

1

X-Gang Box

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

006-Entertainment

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

Power Inlet

SHEET:

Power outlet

PW-

5 of38

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


007-Bar

007-BAR DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CRESCAT-DC

DM-CBL-NP

AQ HDMI-_ _._M

2

TV Location: West wall Height: TBD

2

TV Location: West wall Height: TBD

2

TV Location: West wall Height: TBD

LEFT/RIGHT Location: TBD Height: In-ceiling

S14/4

CRESNET

LIGHTING KEYPAD Location: TBD Height: Standard light switch

1

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

007-Bar

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-

6 of38

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


009-Stair

009-STAIR DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

CRESNET

CRESNET

1

LIGHTING KEYPAD Location: East wall Height: Standard light switch

1

THERMOSTAT/TEMP. SENSOR Location: TBD Height: Standard thermostat

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

009-Stair

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-

7 of38

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


101-Entry

101-ENTRY DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

CRESNET

LIGHTING KEYPAD Location: East wall entry Height: Standard light switch

1

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

101-Entry

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-

8 of38

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


102-Gallery

102-GALLERY DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

CRESNET

CRESNET

1

LIGHTING KEYPAD Location: TBD Height: Standard light switch

1

THERMOSTAT/TEMP. SENSOR Location: TBD Height: Standard thermostat

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

102-Gallery

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-

9 of38

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


103-Dining

103-DINING DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

CRESNET

CRESNET

1

LIGHTING KEYPAD Location: East entry Height: Standard light switch

1

THERMOSTAT/TEMP. SENSOR Location: TBD Height: Standard thermostat

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

103-Dining

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-10of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


104-Hearth

104-HEARTH DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CRESCAT-DC

DM-CBL-NP

AQ HDMI-_ _._M

2

TV Location: North wall Height: TBD

2

TV Location: North wall Height: TBD

2

TV Location: North wall Height: TBD

FRONT LEFT Location: North wall Height: In-wall

S14/2

FRONT CENTER Location: North wall Height: In-wall

S14/2

FRONT RIGHT Location: North wall Height: In-wall

S14/2

REAR LEFT/RIGHT Location: TBD Height: In-ceiling

S14/4

SUBWOOFER Location: West wall Height: In-wall

S14/4

LEGEND CAT5e Keypad CAT5e Phone CAT5e Network

CRESNET

1

LIGHTING KEYPAD Location: West wall sliding door Height: Standard light switch

14/2 Speaker 14/4 Speaker Mon OMC/2C SVRG6 SVRG6 RG6 Quad RGB6C/2CATe RGB3C Mini Component Video HDMI 2 Shielded PR Analog Audio Digital Audio Cresnet Crescat-DC Crescat-Q Romex Conduit (flexible) Conduit (PVC)

1

X-Gang Box

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

104-Hearth

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

Power Inlet

SHEET:

Power outlet

PW-11of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


105-Kitchen

105-KITCHEN DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CRESNET

CRESCAT-DC

DM-CBL-NP

AQ HDMI-_ _._M

1

AV KEYPAD Location: West wall sliding door Height: Standard keypad

2

TV Location: East wall Height: TBD

2

TV Location: East wall Height: TBD

2

TV Location: East wall Height: TBD

LEFT/RIGHT Location: TBD Height: In-ceiling

S14/4

CRESNET

CRESNET

CRESNET

CLIENT:

LTD Regency Omaha, NE

1

LIGHTING KEYPAD Location: West wall sliding door Height: Standard light switch

1

LIGHTING KEYPAD Location: East wall Height: Standard light switch

1

THERMOSTAT/TEMP. SENSOR Location: East wall Height: Standard thermostat

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

105-Kitchen

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-12of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


107-Library

107-LIBRARY DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

CRESNET

AV KEYPAD Location: TBD Height: Standard keypad

1

LEFT/RIGHT Location: TBD Height: In-ceiling

S14/4

CRESNET

LIGHTING KEYPAD Location: TBD Height: Standard light switch

1

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

107-Library

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-13of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


108-Hall

108-HALL DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

CRESNET

LIGHTING KEYPAD Location: TBD Height: Standard light switch

1

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

108-Hall

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-14of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


109-M Bed

109-M BED DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

CRESNET

CRESNET

CRESNET

1

LIGHTING KEYPAD Location: East wall – his bedside Height: Standard light switch

1

LIGHTING KEYPAD Location: East wall – her bedside Height: Standard light switch

1

THERMOSTAT/TEMP. SENSOR Location: North wall Height: Standard thermostat

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

109-M Bed

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-15of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


110-Sitting

110-SITTING DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CRESCAT-DC

DM-CBL-NP

AQ HDMI-_ _._M

2

TV Location: West wall Height: TBD

2

TV Location: West wall Height: TBD

2

TV Location: West wall Height: TBD

LEFT/RIGHT Location: TBD Height: In-wall

S14/4

22/2pr

SUBWOOFER Location: TBD Height: In-cabinet

1

SUBWOOFER Location: TBD Height: In-wall

S14/4

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

110-Sitting

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-16of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


111-Exercise

111-EXERCISE DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CRESCAT-DC

DM-CBL-NP

AQ HDMI-_ _._M

2

TV Location: East wall Height: TBD

2

TV Location: East wall Height: TBD

2

TV Location: East wall Height: TBD

LEFT/RIGHT Location: TBD Height: In-ceiling

S14/4

CRESNET

CRESNET

CLIENT:

LTD Regency Omaha, NE

1

LIGHTING KEYPAD Location: East wall door Height: Standard light switch

1

THERMOSTAT/TEMP. SENSOR Location: East wall door Height: Standard thermostat

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

111-Exercise

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-17of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


114-Laundry

114-LAUNDRY DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CRESCAT-DC

DM-CBL-NP

AQ HDMI-_ _._M

CRESNET

CRESNET

CLIENT:

LTD Regency Omaha, NE

2

TV Location: TBD Height: TBD

2

TV Location: TBD Height: TBD

2

TV Location: TBD Height: TBD

1

LIGHTING KEYPAD Location: South wall entry Height: Standard light switch

1

THERMOSTAT/TEMP. SENSOR Location: South wall entry Height: Standard thermostat

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

114-Laundry

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-18of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


115-M Bath

115-M BATH DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CRESCAT-DC

DM-CBL-NP

AQ HDMI-_ _._M

2

TV Location: East wall Height: TBD

2

TV Location: East wall Height: TBD

2

TV Location: East wall Height: TBD

LEFT/RIGHT Location: TBD Height: In-ceiling

S14/4

STEREO Location: Shower Height: In-ceiling

S14/4

CRESNET

CRESNET

CLIENT:

LTD Regency Omaha, NE

1

LIGHTING KEYPAD Location: East wall – her vanity Height: Standard light switch

1

LIGHTING KEYPAD Location: East wall – his vanity Height: Standard light switch

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

115-M Bath

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-19of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


119-Jeff's Office

119-JEFF'S OFFICE DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CRESCAT-DC

DM-CBL-NP

AQ HDMI-_ _._M

2

TV Location: South wall Height: TBD

2

TV Location: South wall Height: TBD

2

TV Location: South wall Height: TBD

LEFT/RIGHT Location: TBD Height: In-ceiling

S14/4

CRESNET

CRESNET

CLIENT:

LTD Regency Omaha, NE

1

LIGHTING KEYPAD Location: East wall entry Height: Standard light switch

1

THERMOSTAT/TEMP. SENSOR Location: East wall entry Height: Standard thermostat

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

119-Jeff's Office

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-20of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


122-2 Car

122-2 CAR DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

CRESNET

CRESNET

1

LIGHTING KEYPAD Location: East wall outdoor entry Height: Standard light switch

1

THERMOSTAT/TEMP. SENSOR Location: South wall entry Height: Standard thermostat

DOOR SENSOR Location: East wall – between door 1/2 Height: Top of door

22/2pr

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

122-2 Car

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-21of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


124-Powder

124-POWDER DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

CRESNET

LIGHTING KEYPAD Location: Entry Height: Standard light switch

1

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

124-Powder

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-22of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


125-Drop

125-DROP DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

CRESNET

CRESNET

CRESNET

1

LIGHTING KEYPAD Location: North wall entry Height: Standard light switch

1

LIGHTING KEYPAD Location: East wall entry Height: Standard light switch

1

LIGHTING KEYPAD Location: West wall pocket door Height: Standard light switch

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

125-Drop

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-23of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


127-Danielle's Office

127-DANIELLE'S OFFICE DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CRESCAT-DC

DM-CBL-NP

AQ HDMI-_ _._M

2

TV Location: Northeast wall Height: TBD

2

TV Location: Northeast wall Height: TBD

2

TV Location: Northeast wall Height: TBD

LEFT/RIGHT Location: TBD Height: In-ceiling

S14/4

CRESNET

LIGHTING KEYPAD Location: North wall entry Height: Standard light switch

1

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

127-Danielle's Office

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-24of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


129-3 Car

129-3 CAR DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

CRESNET

CRESNET

1

LIGHTING KEYPAD Location: North wall outdoor entry Height: Standard light switch

1

THERMOSTAT/TEMP. SENSOR Location: East wall entry Height: Standard thermostat

DOOR SENSOR Location: North wall – between door 1/2 Height: Top of door

22/2pr

DOOR SENSOR Location: North wall – between door 2/3 Height: Top of door

22/2pr

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

129-3 Car

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-25of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


130-Stair

130-STAIR DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

CRESNET

CRESNET

1

LIGHTING KEYPAD Location: West wall Height: Standard light switch

1

LIGHTING KEYPAD Location: East wall Height: Standard light switch

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

130-Stair

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-26of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


202-Balcony

202-BALCONY DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

CRESNET

LIGHTING KEYPAD Location: East wall Height: Standard light switch

1

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

202-Balcony

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-27of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


203-Hallway

203-HALLWAY DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

CRESNET

LIGHTING KEYPAD Location: South wall entry Height: Standard light switch

1

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

203-Hallway

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-28of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


206-Playroom

206-PLAYROOM DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CRESCAT-DC

DM-CBL-NP

AQ HDMI-_ _._M

2

TV Location: West wall Height: TBD

2

TV Location: West wall Height: TBD

2

TV Location: West wall Height: TBD

FRONT LEFT Location: TBD Height: In-ceiling

S14/2

FRONT CENTER Location: TBD Height: In-ceiling

S14/2

FRONT RIGHT Location: TBD Height: In-ceiling

S14/2

REAR LEFT/RIGHT Location: TBDl Height: In-ceiling

S14/4

22/2pr

SUBWOOFER Location: TBD Height: In-cabinet

1

LEGEND CAT5e Keypad CAT5e Phone CAT5e Network

SUBWOOFER Location: TBD Height: In-wall

S14/4

14/2 Speaker 14/4 Speaker Mon OMC/2C SVRG6 SVRG6 RG6 Quad RGB6C/2CATe RGB3C Mini Component Video HDMI

CRESNET

CRESNET

2 Shielded PR Analog Audio Digital Audio

1

LIGHTING KEYPAD Location: West wall entry Height: Standard light switch

1

THERMOSTAT/TEMP. SENSOR Location: West wall entry Height: Standard thermostat

Cresnet Crescat-DC Crescat-Q Romex Conduit (flexible) Conduit (PVC)

1

X-Gang Box

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

206-Playroom

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

Power Inlet

SHEET:

Power outlet

PW-29of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


208-Bedroom

208-BEDROOM DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

CRESNET

LIGHTING KEYPAD Location: North wall entry Height: Standard light switch

1

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

208-Bedroom

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-30of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


209-Bedroom

209-BEDROOM DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

CRESNET

LIGHTING KEYPAD Location: North wall entry Height: Standard light switch

1

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

209-Bedroom

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-31of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


210-Bath

210-BATH DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

CRESNET

LIGHTING KEYPAD Location: West wall entry Height: Standard light switch

1

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

210-Bath

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-32of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


211-Bath

211-BATH DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

CRESNET

LIGHTING KEYPAD Location: East wall entry Height: Standard light switch

1

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

211-Bath

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-33of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


KITCHEN - 001

STRUCTURED WIRING DETAILED INSTRUCTIONS A 1-gang box should be used for each of the keypad locations unless specified otherwise.

CAT5e (gray)

1

PHONE Location: Right side of island Height: TBD

2

CATV Location: TV niche Height: TBD

CRESCAT-DC DM-CBL-NP

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

SITTING ROOM - 002 CAT5e (gray)

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

1

PHONE Location: TBD Height: In-floor

2

CATV Location: TV niche Height: TBD

CRESCAT-DC DM-CBL-NP

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

KRISTI’S OFFICE - 003 CAT5e (blue)

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

CAT5e (gray)

1

PHONE/NETWORK Location: Shared kitchen wall Height: 24" ABFF

1

PHONE/NETWORK Location: Shared garage wall Height: 24" ABFF

CAT5e (blue) CAT5e (gray)

LEGEND CAT5e Keypad CAT5e Phone CAT5e Network 14/2 Speaker 14/4 Speaker Mon OMC/2C SVRG6 SVRG6 RG6 Quad RGB6C/2CATe RGB3C Mini Component Video HDMI 2 Shielded PR Analog Audio Digital Audio Cresnet Crescat-DC Crescat-Q Romex Conduit (flexible) Conduit (PVC)

1

X-Gang Box

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

Structured Wiring

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

Power Inlet

SHEET:

Power outlet

PW-34of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


AREA: SITTING ROOM

LOCATION: ISLAND

LOCATION: IN-FLOOR

AREA: KRISTI’S OFFICE

AREA: KRISTI’S OFFICE

NETWORK

PHONE PHONE/NETWORK 4 PORT

AREA: KITCHEN

LOCATION: UNDER DESK 24" ABFF

LOCATION: UNDER DESK 24" ABFF

AREA: KITCHEN

AREA: SITTING ROOM

LOCATION: INCABINET

LOCATION: INCABINET

AREA: KRISTI’S OFFICE

LOCATION: UNDER DESK 24" ABFF

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

Wallplates

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

SHEET:

PW-35of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


KITCHEN - 001

LIGHTING DETAILED INSTRUCTIONS

CRESNET

1

A 1-gang box should be used for each of the keypad locations unless specified otherwise.

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

KEYPAD Location: East wall Height: Standard above counter

SITTING ROOM - 002 CRESNET

1

KEYPAD Location: Left of deck doorway Height: Standard lighting keypad

KRISTI’S OFFICE - 003 CRESNET

1

KEYPAD Location: Left of office entry Height: Standard lighting keypad

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

STAIR - 006 CRESNET

1

KEYPAD Location: Right of deck doorway Height: Standard lighting keypad

DINING ROOM - 007 CRESNET

1

KEYPAD Location: Left of MBR doorway Height: Standard lighting keypad

GARAGE - 007 CRESNET

1

KEYPAD Location: Right of garage doorway Height: Standard lighting keypad

LIVING ROOM - 010

LEGEND

CRESNET

1

CAT5e Keypad CAT5e Phone CAT5e Network 14/2 Speaker 14/4 Speaker Mon OMC/2C

KEYPAD Location: Just inside hallway wall Height: Standard lighting keypad

MAIN FLOOR HALLWAY - 011

SVRG6 SVRG6 RG6 Quad

CRESNET

RGB6C/2CATe RGB3C Mini Component Video HDMI

CRESNET

1

KEYPAD Location: Left of garage doorway Height: Standard lighting keypad

1

KEYPAD Location: TBD Height: Standard lighting keypad

2 Shielded PR Analog Audio Digital Audio Cresnet Crescat-DC Crescat-Q

ENTRY - 012 CRESNET

1

KEYPAD Location: Right of entry doorway Height: Standard lighting keypad

Romex Conduit (flexible) Conduit (PVC)

1

X-Gang Box

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

Lighting

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

Power Inlet

SHEET:

Power outlet

PW-36of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


MAIN FLOOR HALLWAY

CLIMATE DETAILED INSTRUCTIONS

CRESNET

1

A 1-gang box should be used for each of the keypad locations unless specified otherwise.

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack from floor at HR rack location to provide ample room for installation, cable mgmt and servicing.

THERMOSTAT Location: Same as existing t-stat Height: Standard audio keypad

OUTDOOR TEMP SENSOR Location: Basement level TBD Height: Approx. 5ft off of ground

CRESNET

ROUGH-IN STUBOUT

2ND FLOOR HALLWAY CRESNET

1

THERMOSTAT Location: Same as existing t-stat Height: Standard audio keypad

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

LEGEND CAT5e Keypad CAT5e Phone CAT5e Network 14/2 Speaker 14/4 Speaker Mon OMC/2C SVRG6 SVRG6 RG6 Quad RGB6C/2CATe RGB3C Mini Component Video HDMI 2 Shielded PR Analog Audio Digital Audio Cresnet Crescat-DC Crescat-Q Romex Conduit (flexible) Conduit (PVC)

1

X-Gang Box

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

Climate

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

Power Inlet

SHEET:

Power outlet

PW-37of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd


OUTDOOR

SHADES DETAILED INSTRUCTIONS

PHOTOCELL SENSOR Location: Not in direct sunlight Height: Under eave

CRESNET

A 1-gang box should be used for each of the keypad locations unless specified otherwise.

ROUGH-IN STUBOUT

Leave 5-6 feet of slack at room locations to provide ample room for installation and servicing.

Leave 8-10 feet of slack at HR rack location here to provide ample room for installation, cable mgmt and servicing.

All wires must be clearly labeled w/ labels or white tape w/ black marker or by some other means.

We need (1) dedicated isolated ground outlet here. This will be connected to the housewide audio equipment.

LEGEND CAT5e Keypad CAT5e Phone CAT5e Network 14/2 Speaker 14/4 Speaker Mon OMC/2C SVRG6 SVRG6 RG6 Quad RGB6C/2CATe RGB3C Mini Component Video HDMI 2 Shielded PR Analog Audio Digital Audio Cresnet Crescat-DC Crescat-Q Romex Conduit (flexible) Conduit (PVC)

1

X-Gang Box

CLIENT:

LTD Regency Omaha, NE

TITLE:

COPYRIGHT Prewire documentation

AREA/ROOM:

Shades

DATE:

11/19/2010

SCALE:

None

DRAWN:

Sam G

Power Inlet

SHEET:

Power outlet

PW-38of38 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 Drawing-Prewire_docs-LTD-101119.vsd