Thermal Qualification Analysis of the Radiation Detector Assembly for Power Plants

Page 1

Outsourcing Services

Phone: +1-408-338-8047 Email: info@hitechcaddservices.com

Your Trusted Outsourcing Partner

Hi-Tech Outsourcing Services 547 Moreland Way Santa Clara, CA 95054

CASE STUDY

Engineering Design Services Engineering Design & Drafting | CAE Services: CFD & FEA | Reverse Engineering Rapid Prototyping | Product Design | Value Engineering PLM Services | Technical Documentation

Outsourcing Services

Hi-Tech House, Near Gurukul Tower, Gurukul, Ahmedabad - 380052 Gujarat, India Phone: +91-794-000-3252 | Fax : +91-794-000-3202 Website: http://www.hitechcaddservices.com | E-Mail: info@hitechcaddservices.com

Your Trusted Outsourcing Partner

Copyright Š 2015 Hi-Tech Outsourcing Services All Rights Reserved


Thermal Qualification Analysis of the Radiation Detector Assembly for Power Plants Case Study Highlights The Client Industry : Thermal Radiation Detection Systems Manufacturer The Objective: Determining maximum temperature at the detector based on the thermal load curve at outer housing of the radiation detector system. The Solution: A detailed three dimensional Finite Element Model was constructed for Thermal Qualification analysis of the Detector Assembly. The analysis was performed to determine the maximum temperature of the detector by applying the Thermal Load Curve at the outer Housing which is having a very high peak for a very small duration. Results allowed client to effectively evaluate the system design prior to actual production. The Challenges:

A leading manufacturer of thermal Radiation Detection System for power plants consulted Hi-Tech to virtually test their new radiation detection system design, considering thermal parameters. Their prime objective was to reduce physical tests by incorporating virtual simulations early during the design phase.

The Solution: A detailed three dimensional Finite Element Model was constructed for Thermal Qualification analysis of the Detector Assembly. The software used to perform Thermal analysis was ANSYS v13.0 Mechanical Module. The model design and geometry was done using Solid Works Software. The analysis was performed to determine the maximum temperature of the detector by applying the Thermal Load Curve at the outer Housing which is having a very high peak for a very small duration. The objective was to find out the maximum temperature at the Detector when this peak temperature occurs at the outer Housing.

? Accurate modeling of the detection device to capture

physics during thermal loading ? Delivering solution results with tight deadlines to

ensure reduced development time

Benefits: ? Shortened product development time with virtual

simulations ? Reduced cost required in validating the design through

physical test trials ? Provided opportunity for the manufacturer to implement

alternative design concepts

About Hi-Tech

Author: Gaurang Trivedi

Hi-Tech Outsourcing Services is a specialist firm providing engineering solutions to organizations across the globe. We have extensive experience in providing concept to manufacturing and post-manufacturing solutions to clients with a team of expert design engineers, CAD professionals and simulation analysts. We are based in India and USA, serving 24x6, with a world-class infrastructure, hardware and software capabilities to address complex engineering problems with least turn around time.


Outsourcing Services

Phone: +1-408-338-8047 Email: info@hitechcaddservices.com

Your Trusted Outsourcing Partner

Hi-Tech Outsourcing Services 547 Moreland Way Santa Clara, CA 95054

USA California 547 Moreland Way Santa Clara, CA 95054 Phone: +1-408-338-8047 E-Mail: sales@hitechos.com

New York, NY 50 Riverside Drive, New York, NY 10024 USA E-Mail: info@hitechos.com

EUROPE Scandinavia - Denmark Indslevvej 26, 5580, Nr. Aaby, Denmark

Benelux - Netherlands Laathof 24 4851 ET, Ulvenhout, Netherlands

INDIA Ahmedabad 5th & 9th Floor, Commerce House - 4, 100 Feet Road, Prahladnagar, Ahmedabad - 380015 Gujarat, India

Gandhinagar 3rd Floor, Chanakya Plaza, Opp. Swagat I, New C.G. Road, Chandkheda, Ahmedabad - 382424 Gujarat, India

Copyright Š 2015 Hi-Tech Outsourcing Services All Rights Reserved

Cochin 43-A, E Block, 3rd Floor, Cochin Special Economic Zone (CSEZ), Kakkanad, Cochin - 682037 Kerala, India


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.