www.vorpa.com
Catalogo Prodotti Technical Catalogue
50
YEARS OF EXPERIENCE BEHIND
ANCHORS
WHATEVER YOU NEED
HAS THE RIGHT SOLUTIONS
No obstacle
too big
no challenge
too great with
We want to help build your success by producing more and more advanced fastening systems.
No obstacle too big, no challenge too great. Vorpa Srl Via San Leo 5, 47838 Riccione - RN - Italy Tel. +39 0541 607111 Fax +39 0541 691847 www.vorpa.com - vorpa@vorpa.com
Made by people COMPETITIVENESS COMES FROM THE STRENGTH OF THE GROUP
QUALITY OF SERVICE Vorpa is aware that development and growth depend on the level of customer satisfaction and its degree of loyalty. For this reason, it pays close attention to the quality of the standards of the services offered. The company constantly strives to ensure that the needs expressed by customers are adequately met, concentrating the management of the entire organization and human resources to achieve objectives strongly oriented towards trust, safety and reliability.
Vorpa’s culture is based on team spirit, on the integration of skills and teamwork. The Vorabbi family has always been aware that at the basis of the consolidation and development of the company there is, and must be, the cohesion of efforts of responsible people. Numerous Vorpa actions are therefore aimed at spreading and improving the team spirit, which contributes to giving the company a precise and strong identity. Hence the numerous strengths, true corporate assets.
TECHNOLOGY The technology that works alongside Vorpa men is aimed at making work more effective, faster and safer. From design to experimentation, from production to control, all operations are coordinated by cuttingedge tools and machines in the sector. The reliability of Vorpa anchors is guaranteed by a rigid system of certified internal controls corresponding to each processing phase. ORGANIZATION A customer who enters Vorpa never has the impression of being in front of things bigger than him. Yet by closely observing our way of working, he immediately notices the high organization and professionalism achieved today by the company. LOGISTICS The large warehouse with high storage capacity allows efficient management of order processing supported by automatic handling systems connected to the latest generation software. The interface with the company management system allows you to obtain all the information relating to the preparation of materials in real time.
Video Made by people su vorpa.com
TECHNICAL DOCUMENTATION An extensive documentation program is available to technicians and professionals. Test reports, certifications, calculation software and information in general are contained in this general catalog and on the web, while a series of separate sectoral technical notebooks can be obtained on request. The Vorpa technical office is prepared to offer practical advice and solutions for the best fixing. SHIPMENTS A warehouse of over 3000 references fed in a full-bodied and continuous way is the real strength of the company. This allows you to fulfill complete orders quickly and to satisfy even the most urgent requests. The packaging is treated in detail, the goods are carefully packed to reach the customer in the best way. Transportation is managed by Vorpa on behalf of customers using the best national carriers. COMMUNICATION AS A COMPANY MIRROR Participation in trade fairs in Italy and abroad, sports sponsorship, advertising in stadiums, in specialized magazines, availability of media products, interactive catalogs, ad hoc commercial network, targeted marketing, brochures and promotional publications.
4
www.vorpa.com INTERNET
www.vorpa.com, the richest site in Italian fixing. A safe guide for information and work. • 5 years of history • catalogue • announcements • information and services • news and events • price list • commercial network • reserved customer area • datasheet
SOFTWARE DESIGN Vorpa’s competence and service as a useful tool for the job.
Calculation Software CALCULanchor Suite
CALCULanchor 5.0 helps designers in choosing and sizing anchors according to the application. Possibility of different types of load and installations of single or group anchors. Directly downloadable from the website for all Vorpa customers, technicians and designers. Features: • 3D real time graphics • Extreme ease of use, all in one screen • Calculation on numerous plate geometries • Multilingual interface • Optimized insertion depth for chemical anchors • Software update and online database • Printable calculation report • Sizing and design calculation in accordance with
current European legislation
5
European Technical Assesments
Partners
POLITECNICO DI MILANO ENGINEERING STRUCTURAL DEPARTMENT
ITeC
TECHNICAL BUILDING AND TESTING INSTITUTE Bratislava Slovakia
Institut Tecnologia de la Construcció de Catalunya
CERTIFICATO Nr. 50 100 10600 - Rev.005
Quality management system
Si attesta che / This is to certify that IL SISTEMA DI THE QUALITY SYSTEM OF
VORPA S.r.l. SEDE LEGALE E OPERATIVA: REGISTERED OFFICE AND OPERATIONAL SITE:
UNI EN ISO 9001:2015
VIA SAN LEO 5 I-47838 RICCIONE (RN) SEDI OPERATIVA: VEDI ALLEGATO 1 OPERATIONAL SITE: SEE ANNEX 1
This certification certifies that Vorpa’s production activities related to the design, development, manufacture, installation, assistance and marketing are managed and organized with the required requirements in order to offer a quality assurance model.
HAS BEEN FOUND TO COMPLY WITH THE REQUIREMENTS OF
UNI EN ISO 9001:2015 Q
THIS CERTIFICATE IS VALID FOR THE FOLLOWING SCOPE
Progettazione e fabbricazione di ancoranti in acciaio; commercializzazione e distribuzione di prodotti e sistemi per il fissaggio (IAF 17, 29) Design and manufacture of metal anchors; trade and distribution of products and fastening systems (IAF 17, 29)
Per l Organismo di Certificazione For the Certification Body
Validity Dal / From:
2020-09-07
Al / To:
2023-09-06
Data emissione / Issuing Date Andrea Coscia
Direttore Divisione Business Assurance
2020-09-04
PRIMA CERTIFICAZIONE / FIRST CERTIFICATION: 2011-09-07 SUBORDINATA A SORVEGLIANZA PERIODICA A 12 MESI E AL RIESAME COMPLETO DEL SISTEMA DI THE VALIDITY OF THE PRESENT CERTIFICATE DEPENDS ON THE ANNUAL SURVEILLANCE EVERY 12 MONTHS AND ON THE COMPLETE REVIEW OF COMPANY'S MANAGEMENT SYSTEM AFTER THREE-YEARS
6
*
Mechanical heavy duty anchors
Universal and frame fixings
Chemical anchors
Cladding and pipe fixings
*
DIY self service line
w o h w o n k We
to push great ideas forward
products index
from page 21
1
from page 17
2
from page 203
3
from page 251
4
CHEMICAL ANCHORS
MECHANICAL HEAVY DUTY ANCHORS
SCAFFOLDING ANCHORS
FRAME AND GENERAL FIXINGS
8
products index
from page 343
5
from page 361
6
from page 401
7
from page 413
8
FIXING FOR INSULATION
CLADDING AND PIPE FIXINGS
DRILL BITS
SELF SERVICE
9
index by base material Pag. concrete
chemical anchors FIXING IN SEISMIC
C1+C2
FIXING IN SEISMIC
C1+C2
VE600
22
VE100
30
VSM
38
VSF
45
VIN
52
PSF
58
PTR
65
PWI
71
PE
77
BOX
83
natural stone
solid brick
perforated brick
MULTISET PLUS BITHUM PHALTE ADESIVI SIGILLANTI POLYMER 700
86
POLYMER 600 CV BITUM PISTOLE MANUALI E PNEUMATICHE ADATTATORE EASYFIT
92
PISTOLE A BATTERIA EASY PRESS 18,0 V
91
ACCESSORI PER L’ANCORAGGIO CHIMICO
95
VF CE
103
self-expanding foams UNIVERSALE B3 TEGOLE E COPPI B3 GRIP FOAM B2 106 STOP FIRE B1 DETERGENTE
114
PISTOLE
114
PER SCHIUME
= good
= good with limitations
10
perforated cement
aerated concrete
plasterboard boards and panels
wood
index by base material Pag. concrete
mechanical heavy duty anchors FIXING IN SEISMIC
C1+C2
FIXING IN SEISMIC
VEX
118
VE.7CE - VE.CE7
125
VE.A
134
VE
140
VSA
144
VSA S
148
VSX
142
VSP C
150
CSB CE
154
CSB COMBI CE
152
VA - VA CE
158
TOP
161
TOP SA
167
AV
170
AVZ
173
VHM
175
AVZ.G
177
VH BU
302
VHS - VTS
179
VO
185
natural stone
solid brick
perforated brick
C1
FIXING IN SEISMIC
C1+C2
FIXING IN SEISMIC
C1+C2
VHS AF - VHS AE 189 TOP AF - TOP AE
187
VH AE
192
ACCESSORI
193
FZ
201
= good
= good with limitations
11
perforated cement
aerated concrete
plasterboard boards and panels
wood
index by base material Pag. concrete
scaffolding anchors
KIT TESTER
natural stone
solid brick
perforated brick
223
TOP T - TOP L 204 CVP
210
VP R8 T
212
VN P
214
VSP P
218
AV P
220
PROLUNGHE
222
ACR
229
AC
233
MORSETTO
237
AV GR
238
VT - VT L
239
antifalling net-holding cables
TOP VT TOP VT L
242
VT P
249 AV OS AV OS L
245
VN G
248
universal fixings VK - TVZ
252
VN
257
SU P
260
VR
262
ZV
264
SV
268
= good
= good with limitations
12
perforated cement
aerated concrete
plasterboard boards and panels
wood
index by base material Pag. concrete
plasterboard fixings VEO
272
HC
273
HZ - HB
275
HU - HS
276
PC - NAF
277
VB
281
VBF - VBG
284
HZB
288
VP
290
VPO - VPI
294
VPC
303
MFR
309
VP R6 - VP R8
313
VPA
322
FSS - FSC
324
VGA - VGN
327
natural stone
solid brick
perforated brick
frame fixings/stand-off installations
THERMOISO PLUS 330 VSL
335
CLICK-UP
338
VPL
344
DISTANZIALI
346
ISO CE
347
ISO CE TL
355
Per lastre e piastrelle
fixing for insulation Pannelli isolamento
= good
= good with limitations
13
perforated cement
aerated concrete
plasterboard boards and panels
wood
index by base material Pag. concrete
clamp and pipe clips IF - IFO
362
BRM - BRG
364
VR INOX A2
365
VRP - CDG
367
natural stone
solid brick
perforated brick
CAV CAV INOX A2
370
CDS 1/2” GAS 367 CFI - CFZ
372
CP- CDG
369
VCR - CT
375
KP - KPO
377
TC
380
SL- SFT - SPS 382 BANDELLA U BOLT
384
EUROFIX
386
MVL - VC
388
TVH - VNS
390
VM
392
VBH
396
TVN - TVM
394
TVNO - TVNK
398
MSQ
399
sanitary fixings
= good
= good with limitations
14
perforated cement
aerated concrete
plasterboard boards and panels
wood
index by base material Pag.
drill bits
concrete natural stone
GOLDCRAFT
402
HARDTEC
403
PM S
404
SDS TURBO
405
SDS PLUS
406
SDS PLUS V4
407
SDS MAX
408
HSS DIN 388
409
HSS TITANIUM
410
HSS Co 5%
411
= good
solid brick
wood
glass brick cement
= good with limitations
15
PVC
metal special alloys
stainless steel
granite gres
klinker
index by base material
DIY products LINEA GIALLA
concrete
SOLID MATERIALS AND MASONRY HANDY BLISTER
INSTANT SHOP
LINEA AZZURRA
ALL BUILDING MATERIALS
HANDY BLISTER
INSTANT SHOP
LINEA GRIGIA
PLASTERBOARDS-PROFILES-PANELS HANDY BLISTER
INSTANT SHOP
LINEA VERDE
SANITARY AND ELECTRICAL FIXINGS
INSTANT SHOP
LINEA VIOLETTO
CONCRETE AND SOLID MATERIALS
HANDY BLISTER
INSTANT SHOP
= good
16
natural stone
solid brick
perforated brick
perforated cement
aerated concrete
plasterboard boards and panels
wood
merchandising
displayers MERCHANDISING
DISPLAYERS AND DIDACTICAL PANELS
TECHNICAL GUIDE
Pag. 419
17
Didactical table
VE600
VE100
VSM
VSF
385 ml
400 ml
300 ml
300 ml
585 ml
600 ml
420 ml
345 ml
400 ml
1400 ml
Certifications FIXING IN SEISMIC
FIXING IN SEISMIC
C1+C2
C1+C2
FIXING IN SEISMIC
C1+C2
EAD 330499-00-0601 Bonded fasteners for use in concrete. For use in cracked and non-cracked concrete M8-M30/Rebar Ø8-32mm
EAD 330499-00-0601 Bonded fasteners for use in concrete. For use in cracked and non-cracked concrete M8-M30/Rebar Ø8-32mm
EAD 330499-00-0601 For use in cracked and noncracked concrete M8-M30/Rebar Ø8-32mm seismic class C1-C2
EAD 330087-00-0601 Systems for post-installed rebar connections with mortar. Rebar Ø8-32mm
EAD 330087-00-0601 Systems for post-installed rebar connections with mortar. Rebar Ø8-32mm
EAD 330087-00-0601 Systems for post-installed rebar connections with mortar. Rebar Ø8-32mm
Available from June 2021
CONCRETE
FIRE RATED
Tested for LEED compliancy
CRACKED REINFORCED CONCRETE CONCRETE
Available from June 2021
CONCRETE
See water included
M8 - M30 Ø8 - Ø32
Threaded bar Rebars
FIRE RATED
EAD 330076-00-0604 Metal injection for use in masonry M8-M16
Tested for LEED compliancy
CRACKED REINFORCED CONCRETE CONCRETE
CONCRETE
See water included
M8 - M30 Ø8 - Ø32
EAD 330499-00-601 Option 7 M8-M24/Rebar Ø 8 to 25mm non-cracked concrete EAD 330499-00-601 Option 1 M12-M16 Cracked concrete ETAG 01-05 TR 023 Post-Installed Rebar Ø 8 to 16mm FIRE RATED
FIRE RATED
Tested for LEED compliancy
Tested for LEED compliancy
CRACKED REINFORCED CONCRETE CONCRETE
CONCRETE CRACKED REINFORCED PERFORATED CONCRETE CONCRETE BRICK
See water included
M8 - M30
Threaded bar
Ø8 - Ø32
Rebars
18
Threaded bar Rebars
See water included
M12 - M16 Ø8 - Ø25
Threaded bar
Rebars
Didactical table
VIN
PSF
PTR
PWI
PE
300 ml
165 ml
410 ml
300 ml
410 ml
300 ml
410 ml
410 ml
410 ml
Certifications Certificato su legno da
EAD 330499-00-0601 Bonded fasteners for use in non-cracked concrete M8-M24/Rebar Ø8-25mm
EAD 330076-00-0604 Use category b,c, w/w size:M6-M8-M10-M12
EAD 330087-00-0601 Systems for post-installed rebar connections with mortar. Rebar Ø8-Ø12mm
ETAG 01-05 Option 7 M8-M16 non-cracked concrete
EAD 330076-00-0604 Metal injection for use in masonry M6-M12
* ETAG 01-05 Option 7 M8-M16 non-cracked concrete
ETAG 029 Use category C, w/d size: M8-M10-M12
* Winter type
Tested for LEED compliancy
Tested for LEED compliancy
Tested for LEED compliancy
Tested for LEED compliancy
FIRE RATED 0974/W
CONCRETE
REINFORCED CONCRETE
SOLID BRICK
CONCRETE
SOLID BRICK
WOOD
PERFORATED BRICK
CONCRETE
SOLID BRICK
PERFORATED BRICK
SOLID BRICK
PERFORATED BRICK
See water included
M8 - M24 Ø8 - Ø25
Threaded bar
M8 - M16
M8 - M16
Threaded bar
Rebars
19
Threaded bar
M8 - M16
Threaded bar
1
Chemical anchors
chemical anchors
chemical anchors
Vorpa VE 500 - Fixing in seismic C1+C2 High performance styrene free pure epoxy chemical anchor with European Technical Assesment for cracked concrete, post installed rebar and seismic zone products group Approved for • cracked and non-cracked concrete post-installed rebars Ø8 - Ø25mm • cracked concrete M12-M30 seismic category C1-C2 and rebars Ø12 - Ø32 mm seismic category C1 • non-cracked concrete M8-M30 rebar Ø8 - Ø32 mm
cracked concrete
reinforced concrete
natural stone
solid brick
To fix • structural fixings • heavy duty metal structures • heavy structural works • construction joints • scaffolding links • wall ties, starter bars, studs,bolts & large screws • electric installations plumbing
Also suitable for • natural stone • solid brick
er cato p Certifi smica + si l’area d for e ifi Cert area seismic
VE 500 585ml
FIXING IN SEISMIC
C1+C2
VE 500 385ml
ETAG 001-05 for cracked and uncracked concrete and seismic zone ETAG 001-01 Annex E C1/C2 - M12-M30 C1 - Ø12-Ø32 rebar
CALCULATION SOFTWARE
Tested for LEED compliancy
ETAG 001-05 TR 029 for diamond coring in uncracked concrete M10-M24 Ø10-Ø25 rebar
ETAG 001-05 TR 023 Ø8-Ø25 for post-installed rebar Fire resistance in ETA for post-installed rebar
product code Code
Description
1171 1173 1169
VE 500 385 VE 500 585 VE 500 1400
Content ml
Gun to be used
Shelf life
385 585 1400
side by side 3:1 side by side 3:1 side by side 3:1
24 months 24 months 24 months
Store upright
Examples of applications
22
FIRE RATED
chemical anchors
chemical anchors
Vorpa VE 500 - Fixing in seismic C1+C2 High performance styrene free pure epoxy chemical anchor with European Technical Assesment for cracked concrete, post installed rebar and seismic zone product information Characteristics • a two component chemical anchoring injection system in 3:1 ratio derived from pure epoxy with very high bond strength, developed to anchor threaded rods and rebar into concrete • european Technical Assessment for structural use in cracked concrete • approved for seismic applications with performance category C1 (non structural fixings M12-M30/Ø12-Ø32) and C2 (structural fixings M12-M16) • suitable for high loads featuring large diameter and deep embedment • longer working times make it suitable for large holes, and high temperature • use in wet or flooded environments and fixing holes, or underwater. • high durability, resistance to chemicals • used for diamond drill holes, solvent free resin
cracked concrete
reinforced concrete
natural stone
solid brick
Approval/certifications/testing • 15/0130 – ETA Option1 Cracked Concrete / TR029 / TR045 / C1+C2 Seismic • 13/0470 – ETA TR023 Post Installed Rebar Installations • 14/0395 – ETA for Diamond Drilled Holes • ICC-ES Approval ESR 3853 Cracked and Non-Cracked • Fire Test Report in ETA for post-installed rebar • Wras Approved for use with Potable drinking water approval no. 1309522 • LEED tested 2009 EQ c4.1 SCAQMD rule 1168 (2005) • VOC A+ Rating (Volatile Organic Content) Suggestion for use • performance based on clean holes. • HAMMER DRILLED – blown and then brushed with a stiff metal brush and blown again
installation sequence Clean the hole before the installation
On solid brick
technical data Physical Properties Tensile Strength Compressive Strength Flexural Strength Flexural Modulus E Modulus Density Shrinkage VOC Content
N/mm2 (MPa)
Test Method
29,36 120 39 3706 3420 1,42 kg/dm3 < 0,4% A+
ASTM D638 EN 196 PARTE 1 EN 196 PARTE 1 ASTM D790 EN 196 PARTE 1 -
Minimum Curing Time Concrete Temperature
Gel-working Time
≥ 5°C ≥ 15°C ≥ 25°C ≥ 35°C ≥ 40°C
120 min 60 min 25 min 16 min 10 min
Temperature Ranges Minimum curing Minimum curing time time in dry concrete in wet concrete
50 h 20 h 8h 4h 2,5 h
x2 x2 x2 x2 x2
Range
Concrete Service Temperature
Maximum Long Term Concrete Temperature
Maximum Short Term Concrete Temperature
Range I Range II Range III
-40°C to +40°C -40°C to +60°C -40°C to +72°C
+24°C +43°C +43°C
+40°C +60°C +72°C
Service temperature range: Range of ambient temperatures after installation and during the lifetime of the anchor. Short term temperature: Temperature within the service temperature range which vary over short intervals, e.g. day/ night cycles and freeze/than cycles. Long term temperature: Temperature, within the service temperature range, which will be approximately constant over significant periods of time
Full cure 24 hours All specifications based on supplied mixer Store at temperatures between +5 and +25 degrees, away from direct heat, rain and moisture
23
chemical anchors
chemical anchors
Vorpa VE 500 - Fixing in seismic C1+C2 High performance styrene free pure epoxy chemical anchor with European Technical Assesment for cracked concrete, post installed rebar and seismic zone technical data
cracked concrete
reinforced concrete
natural stone
solid brick
Typical characteristic and design resistance performance with 5.8 grade studding and associated installation data
Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
27
30
33
36
Tension (Nrk)
Shear (Vrk)
19,00 19,00 19,00 28,27 30,20 30,20 39,58 43,80 43,80 56,30 81,60 81,60 73,51 127,40 127,40 90,48 183,60 183,60 119,97 238,00 238,00 135,72 292,00 292,00 148,25 342,12 360,00 174,74 396,07 425,00
9,00
15,00
21,00
39,00
61,00
88,00
115,00
142,50
173,50
212,50
Design Resistance Recommended Load Characteristic distances (kN) (kN) (mm)
Min Edge and Spacing
Tension (Nrd)
(mm) (Cmin Smin)
12,70 12,70 12,70 15,71 20,10 20,10 21,99 29,20 29,20 31,28 54,40 54,40 35,01 84,90 84,90 43,08 122,40 122,40 53,32 159,10 159,10 64,63 194,50 194,50 70,60 162,91 240,60 83,21 188,60 283,33
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
92,00
114,00
138,80
170,00
Tension (Nrec) 9,07 9,07 9,07 11,22 14,36 14,36 15,71 20,86 20,86 22,34 38,86 38,86 25,00 60,64 60,64 30,77 87,43 87,43 38,08 109,52 109,52 46,16 133,33 133,33 50,43 116,36 165,20 59,43 134,72 202,38
Shear (Vrec)
Edge Spacing Edge (Ccr,N) (Scr,N) (Ccr,V)
5,14
80
160
80
40
8,57
100
200
90
50
12,00
120
240
110
60
22,29
160
320
125
80
34,86
200
400
180
100
50,29
240
480
220
120
65,71
270
540
240
135
81,43
300
600
280
150
99,14
330
660
310
165
121,43
360
720
330
180
Nominal Hole Hole Max Embedment diameterdiameter Torque concrete fixture (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 110 240 540 120 280 600 130 300 660 150 340 720
(mm)
(mm)
(Nm)
10
9
10
12
12
20
14
14
40
18
18
80
24
22
120
28
26
160
32
30
180
35
32
200
37
36
250
40
38
300
All data is based on correct installation - see instructions No influence of edge and spacing Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d
Steel failure
Design resistance with various stud strenghts and rebar 5.8 grade steel studding Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30 33 36
10 12 14 18 24 28 32 35 38 40
depth mm
hef failure
embedment depth 60 70 80 90 100 110 12.6 12.7 15.7 18.3 20.1 22.0 25.1 28.3 29.2 31.4 35.3 39.2 43.1 33.2 37.3 41.5 45.6 43.0 47.3 53.2
60
70
80
90
100
110
120
130
47.1 49.8 51.6 58.0 64.5
51.0 53.9 55.9 62.9 69.8 71.4
120
130
140
54.4 58.1 60.2 67.7 75.2 76.9 77.6 140
160
66.4 68.8 77.4 86.0 87.9 88.7 160
200
82.9 86.0 96.7 107.5 109.9 110.8 200
24
240
84.9 103.2 116.1 128.9 131.9 133.0 240
280
120.4 135.4 150.4 153.9 155.2 280
320
122.4 154.7 171.9 175.9 177.4 320
400
480
540
600
159.1 194.5 219.8 240.6 221.7 266.0 283.2 400 480 540 600
660
660
720
720
Fd,s design load
(mm)
(kN)
61 77 93 139 205 285 329 362 438 511
12.7 20.1 29.2 54.4 84.9 122.4 159.1 194.5 240.6 283.2
chemical anchors
chemical anchors
Vorpa VE 500 - Fixing in seismic C1+C2 High performance styrene free pure epoxy chemical anchor with European Technical Assesment for cracked concrete, post installed rebar and seismic zone technical data
cracked concrete
reinforced concrete
Design resistance of resin with various stud strenghts and rebar
natural stone
solid brick
Steel failure
8.8 grade steel studding Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30 33 36
10 12 14 18 24 28 32 35 38 40
depth mm
hef failure
embedment depth 60 70 80 12.6 14.7 16.8 15.7 18.3 20.9 22.0 25.1 31.4 33.2
60
70
80
90 18.8 23.6 28.3 35.3 37.3
90
100 19.5 26.2 31.4 39.2 41.5 43.0
110 120 130 140 160 200 240 280 320 400 480 540 600 660 720 28.8 34.5 43.1 45.6 47.3 53.2
30.9 37.7 47.1 49.8 51.6 58.0 64.5
40.8 51.0 53.9 55.9 62.9 69.8 71.4
44.0 54.9 58.1 60.2 67.7 75.2 76.9 77.6 100 110 120 130 140
45.0 62.7 66.4 68.8 77.4 86.0 87.9 88.7 160
78.4 83.7 82.9 99.5 116.1 130.7 86.0 103.2 120.4 137.5 171.9 188.3 96.7 116.1 135.4 154.7 193.4 232.1 244.8 107.5 128.9 150.4 171.9 214.9 257.9 290.1 299.2 109.9 131.9 153.9 175.9 219.8 263.8 296.7 329.7 362.7 370.1 110.8 133.0 155.2 177.4 221.7 266.0 299.3 332.5 365.8 399.1 200 240 280 320 400 480 540 600 660 720
Fd,s design load
(mm)
(kN)
93 118 143 214 315 438 506 557 674 786
19.5 30.9 45.0 83.7 130.7 188.3 244.8 299.2 370.1 435.7
A-70 stainless steel studding Ø
Ø
stud
hole
hef failure
embedment depth (mm)
(mm)
8 10 12 16 20 24 27 30 33 36
10 12 14 18 24 28 32 35 38 40
depth mm
60 70 80 12.6 13.7 15.7 18.3 20.9 22.0 25.1 31.4 33.2
60
70
80
90
100 110 120 130 140 160 200 240 280 320 400 480 540 600 660 720
21.7 28.3 31.6 35.3 39.2 43.1 47.1 37.3 41.5 45.6 49.8 43.0 47.3 51.6 53.2 58.0 64.5
90
51.0 53.9 55.9 62.9 69.8 71.4
54.9 58.1 60.2 67.7 75.2 76.9 77.6 100 110 120 130 140
58.8 66.4 68.8 77.4 86.0 87.9 88.7 160
82.9 91.7 86.0 103.2 120.4 132.1 1 80.2 1 98.1 1 109.9 121 1 110.8 133.0 143 200 240 280 320 400 480 540 600 660 720
Fd,s design load
(mm)
(kN)
65 83 100 150 221 307 166 183 221 258
13.7 21.7 31.6 58.8 91.7 132.1 80.2 98.1 121.3 142.8
*1 = tensile strenght 500N/mm2
High bond reinforcing bars Fyk = 800 N/mm2 Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 25 28 32 36 40
10 12 15 20 25 30 35 40 44 50
depth mm
hef failure
embedment depth 60 70 80 11.7 13.7 15.6 14.7 17.1 19.6 19.1 21.8 26.8 28.7
60
70
80
90 17.6 22.0 24.5 30.2 32.3
90
100 19.6 24.4 27.2 33.5 35.9 41.1
110 21.5 26.9 30.0 36.9 39.5 45.3 50.7
120 23.5 29.3 32.7 40.2 43.1 49.4 55.3
130 25.2 31.8 35.4 43.6 46.7 53.5 59.9 68.5
140 160 200 240 280 320 400 500 560 640 720 800 34.2 38.1 46.9 50.3 57.6 64.5 73.7 79.2
39.1 43.6 53.6 57.5 65.8 73.7 84.3 90.5 95.8 100 110 120 130 140 160
39.3 54.5 56.6 67.0 80.4 93.8 100.6 71.9 86.2 100.5 114.9 143.6 82.3 98.7 115.2 131.7 164.6 205.7 92.2 110.6 129.0 147.5 184.3 230.4 258.1 105.3 126.4 147,5 168.5 210.7 263.3 294.9 337.1 113.1 135.7 158.4 181.0 226.0 282.8 316.7 362.0 119.7 143.6 167.6 191.5 239.4 299.2 335.1 383.0 200 240 280 320 400 500 560 640
25
(mm)
129 161 208 300 438 549 668 763 407.2 902 430.9 478.8 1050 720 800
Fd,s design load
(kN)
25.2 39.3 56.6 100.6 157.1 226.0 308.0 402.1 510.0 628.3
chemical anchors
chemical anchors
Vorpa VE 500 - Fixing in seismic C1+C2 High performance styrene free pure epoxy chemical anchor with European Technical Assesment for cracked concrete, post installed rebar and seismic zone technical data
cracked concrete
reinforced concrete
natural stone
solid brick
Characteristic and Design Load resistances based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non cracked concrete Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
27
30
33
36
Tension (Nrk) 22,62 30,16 60,32 28,27 42,41 94,25 39,58 62,20 135,72 56,30 87,96 225,19 73,51 138,86 326,73 90,48 190,00 434,29 111,97 244,29 549,65 132,72 316,76 678,59 148,25 342,12 752,66 174,74 396,07 838,73
Shear (Vrk)
9,00
15,00
21,00
39,00
61,00
88,00
115,00
142,50
173,50
212,50
Cracked concrete
Design Resistance Recommended Load (kN) (kN) Tension (Nrd) 12,57 16,76 33,51 15,71 23,56 52,36 21,99 34,56 75,40 31,28 48,87 125,11 35,01 66,12 155,58 43,08 90,48 206,81 53,32 116,33 261,74 64,63 150,80 323,14 70,60 162,91 358,41 83,21 188,60 399,40
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
92,00
114,00
138,80
170,00
Tension (Nrec)
Characteristic Resistance (kN)
Shear (Vrec)
8,98 11,97 23,94 11,22 16,83 37,40 15,71 24,68 53,86 22,34 34,91 89,36 25,00 47,23 111,13 30,77 64,63 147,72 38,08 83,09 186,96 46,16 107,71 230,81 50,43 116,37 256,01 59,43 134,72 285,28
Tension (Nrk)
Shear (Vrk)
Design Resistance Recommended Load (kN) (kN) Tension (Nrd)
Shear (Vrd)
Tension (Nrec)
Shear (Vrec)
5,14 Not applicable
Not applicable
Not applicable
8,57
12,00
21,00
22,29
39,00
34,86
61,00
50,29
88,00
65,71
115,00
81,43
142,50
99,14
173,50
121,43
212,50
11,00 17,28 37,70 14,52 23,46 58,08 16,16 30,41 71,81 19,75 40,71 94,79 24,44 51,18 119,96 29,62 63,33 148,10 32,09 66,80 162,91 36,35 73,56 174,49
16,80
31,20
48,80
70,40
92,00
114,00
138,80
170,00
7,85 12,34 26,93 10,37 16,75 41,49 11,54 21,72 51,29 14,11 29,10 67,70 17,46 36,56 85,69 21,16 45,24 105,79 22,92 47,71 116,37 25,97 52,54 124,64
12,00
22,29
34,86
50,29
65,71
81,43
99,14
121,43
Nominal Embedment
(mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 110 240 540 120 280 600 130 300 660 150 340 720
All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C
Bond Strength Factors Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.98
1.00
1.02
1.04
1.06
1.08
1.09
1.10
Influence of environmental conditions in non cracked concrete
Temp I 40°C/24°C
Temp II 60°C/43°C
Temp II 72°C/43°C
M8
M10
M12
M16
M20
M24
M27
M30
M33
M36
Dry and Wet
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
Flooded
1.00
0.94
0.87
0.79
0.71
0.65
0.65
0.60
0.57
0.55
Dry and Wet
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
Allagato
0.65
0.63
0.61
0.59
0.57
0.54
0.50
0.49
0.46
0.44
Dry and Wet
0.57
0.56
0.54
0.53
0.52
0.51
0.50
0.49
0.47
0.46
Flooded
0.57
0.54
0.52
0.51
0.50
0.49
0.46
0.45
0.43
0.42
26
chemical anchors
chemical anchors
Vorpa VE 500 - Fixing in seismic C1+C2 High performance styrene free pure epoxy chemical anchor with European Technical Assesment for cracked concrete, post installed rebar and seismic zone technical data
cracked concrete
reinforced concrete
natural stone
solid brick
Bond Strength Factors Influence of environmental conditions in cracked concrete
Temp I 40°C/24°C
Temp II 60°C/43°C
Temp II 72°C/43°C
M8
M10
M12
M16
M20
M24
M27
M30
M33
M36
Dry and Wet
n/a
n/a
0.50
0.48
0.46
0.45
0.44
0.42
0.41
0.39
Flooded
n/a
n/a
0.50
0.42
0.38
0.38
0.35
0.30
0.27
0.24
Dry and Wet
n/a
n/a
0.32
0.31
0.30
0.29
0.29
0.28
0.27
0.26
Allagato
n/a
n/a
0.32
0.29
0.28
0.27
0.27
0.25
0.24
0.23
Dry and Wet
n/a
n/a
0.27
0.27
0.26
0.25
0.24
0.23
0.23
0.22
Flooded
n/a
n/a
0.27
0.27
0.26
0.25
0.24
0.23
0.23
0.22
Characteristic and Design Load resistances for REBAR based on characteristic bond strengths for hef 4d (minimum embedment) to 20d
Non cracked concrete Characteristic Resistance (kN) Ø mm
8
10
12
16
20
25
28
32
Tension (Nrk) 21,11 28,15 56,30 26,39 39,58 87,96 34,31 53,91 117,62 48,25 75,40 193,02 67,86 128,18 301,59 86,39 181,43 431,97 108,37 270,93 541,86 141,55 353,87 707,74
Shear (Vrk)
13,95
21,45
31,05
55,50
86,55
135,00
168,75
220,95
Cracked concrete
Design Resistance Recommended Load (kN) (kN) Tension (Nrd)
Shear (Vrd)
11,73 15,64 31,30 14,66 21,99 48,87 19,06 29,95 65,35 26,81 41,89 107,23 32,31 61,04 143,62 41,14 86,39 205,70 51,61 129,02 258,03 67,40 168,51 337,02
9,30
14,30
20,70
37,00
57,70
90,00
112,50
147,30
Tension (Nrec) 8,38 11,17 22,34 10,47 15,71 34,91 13,61 21,39 46,68 19,15 29,92 76,60 23,08 43,60 102,58 29,39 61,71 146,93 36,86 92,15 184,31 48,15 120,36 240,73
Shear (Vrec)
Characteristic Resistance (kN) Tension (Nrk)
Shear (Vrk)
Design Resistance Recommended Load (kN) (kN) Tension (Nrd)
Shear (Vrd)
Tension (Nrec)
Nominal Embedment
Shear (Vrec)
(mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 500 112 280 560 128 320 640
6,64 Not applicable
Not applicable
Not applicable
10,21 19,79 31,10 67,86 26,14 40,84 104,55 33,93 64,09 150,80 43,20 90,71 215,99 54,19 135,47 270,93 70,77 176,93 353,87
14,79
26,43
41,21
64,29
80,36
105,21
31,05
55,50
86,55
135,00
168,75
220,95
11,00 17,28 37,70 14,52 22,69 58,08 16,16 30,52 71,81 20,57 43,20 102,85 25,80 64,51 129,02 33,70 84,25 168,51
20,70
37,00
57,70
90,00
112,50
147,30
7,85 12,34 26,93 10,37 16,21 41,49 11,54 21,80 51,29 14,69 30,86 73,46 18,43 46,08 92,15 24,07 60,18 120,36
14,79
26,43
41,21
64,29
80,36
105,21
All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C
Bond Strength Factors - REBAR Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
C55/67
C60/75
C70/85
C80/96
C90/105
0.98
1.00
1.02
1.04
1.06
1.08
1.09
1.10
1.10
1.12
1.13
1.14
1.15
27
chemical anchors
chemical anchors
Vorpa VE 500 - Fixing in seismic C1+C2 High performance styrene free pure epoxy chemical anchor with European Technical Assesment for cracked concrete, post installed rebar and seismic zone technical data
cracked concrete
reinforced concrete
natural stone
solid brick
Bond Strength Factors - REBAR Influence of environmental conditions in non cracked concrete
Temp I 40°C/24°C
Temp II 60°C/43°C
Temp II 72°C/43°C
Ø8
Ø10
Ø12
Ø16
Ø20
Ø25
Ø28
Ø32
Dry and Wet
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
Flooded
1.00
0.94
0.90
0.85
0.80
0.71
0.65
0.63
Dry and Wet
0.67
0.65
0.63
0.62
0.61
0.60
0.60
0.59
Flooded
0.65
0.64
0.61
0.59
0.58
0.56
0.55
0.47
Dry and Wet
0.60
0.58
0.57
0.56
0.56
0.55
0.54
0.53
Flooded
0.58
0.56
0.53
0.50
0.47
0.45
0.43
0.41
Influence of environmental conditions in cracked concrete
Temp I 40°C/24°C
Temp II 60°C/43°C
Temp II 72°C/43°C
Ø8
Ø10
Ø12
Ø16
Ø20
Ø25
Ø28
Ø32
Dry and Wet
n/a
n/a
0.55
0.47
0.44
0.43
0.42
0.41
Flooded
n/a
n/a
0.55
0.42
0.40
0.38
0.36
0.35
Dry and Wet
n/a
n/a
0.30
0.28
0.26
0.24
0.23
0.23
Flooded
n/a
n/a
0.30
0.27
0.25
0.23
0.22
0.22
Dry and Wet
n/a
n/a
0.30
0.26
0.25
0.24
0.23
0.22
Flooded
n/a
n/a
0.30
0.26
0.24
0.23
0.23
0.22
Post installed rebar connections Minimum anchorage length 1) and lap splice length for C20/25 and maximum installation length (l max) Rebar
N/mm2 = MPa
lb,min (mm)
lo,min (mm)
lmax,min (mm)
Ø ds
fy,k (N/mm2)
8mm
500
113
200
1000
10mm
500
142
200
1000
12mm
500
170
200
1200
14mm
500
198
210
1400
16mm
500
227
240
1600
20mm
500
284
300
2000
22mm
500
312
330
2000
24mm
500
340
360
2000
25mm
500
354
375
2000
1) According to EN 1992-1-1:2004 lb,min (8.6) e lo,min (8.11) for good bond conditions and as = 1,0 with maximum yeld stress for rebar B500 e yM - 1,15 Design values of the ultimate bond resistance fbd 1) in N/mm2 for all drilling methods for good conditions Rebar Ø
Concrete Class
Ø dsw
C12/15
C16/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/60
C50/60
8mm to 25mm
1.6
2
2.3
2.7
3
3.4
3.7
4
4.3
1) Tabulated values for fbd are valid for good bond condition according to EN 1992-1-1:2004. For all other bond conditions multiply the values for fbd by 0.7.
28
chemical anchors
chemical anchors
Vorpa VE 500 - Fixing in seismic C1+C2 High performance styrene free pure epoxy chemical anchor with European Technical Assesment for cracked concrete, post installed rebar and seismic zone technical data Effect of anchor spacing - Tension Anchor spacing (mm) (mm) 40 50 60 70 80 90 100 120 150 160 175 200 225 240 250 275 280 300 320 350 400 440 480 540 600 660 720 800
0,64 0,67 0,70 0,73 0,76 0,79 0,82 0,87 0,96 1,00
10
0,63 0,65 0,67 0,69 0,72 0,74 0,79 0,86 0,88 0,92 1,00
12
0,63 0,64 0,66 0,68 0,70 0,74 0,80 0,82 0,85 0,90 0,95 1,00
16
0,63 0,64 0,65 0,68 0,73 0,74 0,76 0,80 0,84 0,86 0,87 0,91 0,92 0,95 1,00
reinforced concrete
natural stone
solid brick
Effect of edge distance - Tension Edge distance
Stud/Rebar diameter 8
cracked concrete
20
0,63 0,65 0,68 0,70 0,71 0,74 0,77 0,79 0,80 0,83 0,84 0,86 0,88 0,92 1,00
24
0,63 0,65 0,66 0,67 0,69 0,72 0,73 0,74 0,76 0,77 0,79 0,81 0,83 0,88 0,92 1,00
27
0,63 0,64 0,65 0,66 0,69 0,71 0,72 0,73 0,75 0,76 0,78 0,80 0,82 0,87 0,91 0,94 1,00
30
0,63 0,63 0,64 0,66 0,68 0,69 0,70 0,72 0,73 0,74 0,76 0,78 0,82 0,85 0,88 0,93 1,00
33
0,63 0,63 0,65 0,67 0,68 0,69 0,71 0,71 0,73 0,74 0,77 0,80 0,83 0,86 0,91 0,96 1,00
36
0,63 0,63 0,65 0,67 0,68 0,68 0,70 0,70 0,72 0,73 0,75 0,78 0,81 0,84 0,88 0,92 0,96 1,00
(mm) 40 50 60 70 80 90 100 110 120 140 160 180 200 220 240 270 300 330 360 400
40
0,63 0,63 0,65 0,66 0,67 0,68 0,69 0,69 0,71 0,72 0,73 0,76 0,79 0,81 0,84 0,88 0,91 0,95 1,00
Stud/Rebar diameter 8 0,64 0,73 0,82 0,90 1,00
10 0,63 0,70 0,77 0,84 0,91 1,00
12
0,63 0,68 0,74 0,80 0,86 0,92 1,00
16
0,63 0,67 0,71 0,76 0,80 0,89 1,00
20
0,63 0,66 0,70 0,77 0,84 0,91 1,00
24
0,64 0,67 0,72 0,78 0,84 0,89 1,00
27
30
0,63 0,70 0,75 0,81 0,86 0,92 1,00
0,63 0,65 0,70 0,76 0,81 0,86 0,94 1,00
33
36
0,63 0,66 0,71 0,75 0,80 0,87 0,94 1,00
0,67 0,71 0,74 0,78 0,82 0,87 0,93 0,98 1,00
40
0,68 0,71 0,75 0,78 0,83 0,88 0,93 0,98 1,00
Effect of edge distance - Shear Edge distance (mm) 40 50 60 70 80 90 100 110 125 140 160 180 200 220 240 280 310 330 400
Bonded anchor VE500 contain a substance listed on annex XVII of the REACH regulation and the Substances of Very High Concern (SVHC) above reportable limits. This substance is Bisphenol A, CAS: 80-05-7. More information on this substance can be found at https://echa.europa.eu/registration-dossier/-/registereddossier/15752/9. Precautions for using this substance have been recommended by its registrants under REACH, as follows: Prevention statements When handling this substance: avoid release to the environment; wear protective gloves and/or clothing, and eye and/or face protection as specified by manufacturer/supplier; avoid breathing the dust, fume, gas, mist, vapours or spray. Response statements In case of incident: If exposed or concerned: get medical advice/ attention. If in eyes: rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do – continue rinsing. If on skin: wash with soap and water.
Stud/Rebar diameter 8 0,25 0,44 0,63 0,81 1,00
10 0,30 0,48 0,65 0,83 1,00
12
0,30 0,44 0,58 0,72 0,86 1,00
16
0,40 0,53 0,67 0,80 1,00
20
0,35 0,44 0,58 0,72 0,91 1,00
24
0,35 0,46 0,62 0,77 0,92 1,00
27
30
0,35 0,51 0,63 0,75 0,88 1,00
0,30 0,35 0,46 0,57 0,68 0,78 1,00
33
36
0,32 0,37 0,46 0,56 0,65 0,84 1,00
0,33 0,43 0,50 0,56 0,63 0,77 1,00 1,00
40
0,32 0,53 0,59 0,72 0,82 0,89 1,00
Examples of applications
29
chemical anchors
chemical anchors
Vorpa VE 100 PURE EPOXY High performance styrene free pure epoxy chemical anchor with European Technical Assesment for cracked concrete, post installed and reinforcing rebars products group Approved for • calcestruzzo fessurato e non fessurato per applicazioni con barre ad aderenza migliorata post-installate da Ø8 a Ø20mm • calcestruzzo fessurato e non fessurato per applicazioni con barre filettate M12-M24 • calcestruzzo non fessurato per applicazioni con ferri da ripresa da Ø12 a Ø24 e barre M12-M24 Also suitable for • calcestruzzo fessurato e non fessurato per applicazioni con barre di misure diverse da ETA • pietra naturale compatta • mattone pieno
i per ferr Ideale presa da ri le for Suitab rebars ing reinforc
VE 100 600ml
cracked concrete
VE 100 400ml
EAD 330087-00-0601 Ø8-Ø20mm per barre postinstallate per calcestruzzo fessurato e non fessurato
EADo330499-00-0601 Ø12 -Ø24mm per ferri da ripresa per calcestruzzo fessurato
product code Code
Description
Content ml
1202 1302
VE 100 400 VE 100 600
400 600
Gun to be used
Shelf life
side by side 3:1 24 months side by side 3:1 24 months
Store upright
Examples of applications
30
natural stone
solid brick
To fix • fissaggi per ferri in acciaio ad aderenza migliorata • strutture metalliche pesanti • fissaggi di tiranti, boccole filettate, ferri per armatura, profili, barre ad aderenza migliorata • riprese di getto- carpenteria pesante • fissaggi su fori carotati e sommersi • fissaggi strutturali
CALCULATION SOFTWARE
Tested for LEED compliancy
reinforced concrete
FIRE RATED
chemical anchors
chemical anchors
Vorpa VE 100 PURE EPOXY High performance pure epoxy chemical anchor with European Technical Assesment for cracked concrete, post installed and reinforcing rebars product information
cracked concrete
reinforced concrete
natural stone
solid brick
Approval/certifications/testing • EAD 330499-00-0601 M12 - M24 barre filettate / Ø12 - Ø24 ferri da ripresa su calcestruzzo fessurato e non fessurato • EAD 330087-00-0601 Ø8 - Ø20 barre ad aderenza post installate + fire test • R240 Fire Test Report SIGGMA • WRAS approvazione per uso continuativo a contatto con acqua potabile no. 1309522. • LEED tested 2009 EQ c4.1 SCAQMD rule 1168 (2005). • VOC A+ Rating (Volatile Organic Content)
Characteristics • ancorante chimico ad iniezione a base resina epossidica pura ratio 1:1 senza stirene, indicata To fix barre filettate e ferri di armatura su calcestruzzo. • valutazione tecnica europea per uso strutturale su calcestruzzo fessurato. • indicato per applicazioni strutturali ad alte prestazioni. • adatto per carichi elevati caratterizzati da diametro ampio e profondità elevata. • i tempi di lavoro lo rendono adatto per fori di grandi dimensioni e alte temperature. • non produce restringimento, ottimo per fissaggi di grande diametro. • si può utilizzare in ambienti umidi o fori allagati o sott’acqua. • elevata durata, forte resistenza agli agenti chimici. • adatto per fori carotati. • fissaggio su ogni tipo di calcestruzzo, legno o altri materiali ad alta compattezza. • rapporto resina catalizzatore 1:1disponibile in due formati
Suggestion for use • performance based on clean holes. • HAMMER DRILLED – blown and then brushed with a stiff metal brush and blown again.
installation sequence Clean the hole before the installation
On solid brick
technical data Physical Properties Compressive Strength Flexural Strength Flexural Modulus Tensile Strength E Modulus VOC Content
N/mm2 (MPa)
Test Method
94,0 52,79 4331,0 26,94 7267 A+
EN ISO 604 / ASTM 695 EN ISO 178 / ASTM 790 EN ISO 178 / ASTM 790 EN ISO 527 / ASTM 638 EN ISO 527 / ASTM 638 -
Minimum Curing Time Concrete temperature
Gel-working Time
5°C 15°C 25°C 35°C 45°C
120 min 60 min 20 min 12 min 6 min
Temperature Ranges Minimum curing Minimum curing time time in dry concrete in wet concrete
960 min 600 min 300 min 180 min 90 min
x2 x2 x2 x2 x2
Range
Concrete Service Temperature
Maximum Long Term Concrete Temperature
Maximum Short Term Concrete Temperature
Range I Range II Range III
-40°C to +40°C -40°C to +60°C -40°C to +72°C
+24°C +43°C +43°C
+40°C +60°C +72°C
Service temperature range: Range of ambient temperatures after installation and during the lifetime of the anchor. Short term temperature: Temperature within the service temperature range which vary over short intervals, e.g. day/ night cycles and freeze/than cycles. Long term temperature: Temperature, within the service temperature range, which will be approximately constant over significant periods of time.
Full cure 24 hours All specifications based on supplied mixer Store at temperatures between +5 and +25 degrees, away from direct heat, rain and moisture
31
chemical anchors
chemical anchors
Vorpa VE 100 PURE EPOXY High performance pure epoxy chemical anchor with European Technical Assesment for cracked concrete, post installed and reinforcing rebars technical data
cracked concrete
reinforced concrete
natural stone
solid brick
Typical characteristic and design resistance performance with 5.8 grade studding and associated installation data Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
27
30
33
36
Tension (Nrk)
Shear (Vrk)
19,00 19,00 19,00 25,45 30,20 30,20 35,63 43,80 43,80 52,28 81,60 81,60 67,86 126,70 127,40 82,94 174,17 183,60 102,64 223,93 238,00 124,41 290,28 292,00 141,51 326,57 360,00 169,65 384,53 425,00
9,00
15,00
21,00
39,00
61,00
88,00
115,00
142,50
173,50
212,50
Design Resistance Recommended Load Characteristic distances (kN) (kN) (mm)
Min Edge and Spacing
Tension (Nrd)
(mm) (Cmin Smin)
12,70 12,70 12,70 14,14 20,10 20,10 19,79 29,20 29,20 29,04 54,40 54,40 32,31 60,30 84,90 39,49 82,94 122,40 48,87 106,63 159,10 59,24 138,23 194,50 67,39 155,51 240,60 80,78 183,10 283,33
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
92,00
114,00
138,80
170,00
Tension (Nrec) 9,07 9,07 9,07 10,10 14,36 14,36 14,14 20,86 20,86 20,74 38,86 38,86 23,08 43,07 60,64 28,21 59,24 87,43 34,91 76,17 10,950 42,32 98,74 133,33 48,13 111,08 165,23 57,70 130,79 202,38
Shear (Vrec)
Edge Spacing Edge (Ccr,N) (Scr,N) (Ccr,V)
5,14
80
160
80
40
8,57
100
200
90
50
12,00
120
240
110
60
22,29
160
320
175
80
34,86
200
400
225
100
50,29
240
480
280
120
65,71
270
540
240
135
81,43
300
600
280
150
99,14
330
660
310
165
121,43
360
720
330
180
Nominal Hole Hole Max Embedment diameterdiameter Torque concrete fixture (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 110 240 540 120 280 600 130 300 660 150 340 720
(mm)
(mm)
(Nm)
10
9
10
12
12
20
14
14
40
18
18
80
24
22
120
28
26
160
32
30
180
35
32
200
37
36
250
40
38
300
= Steel failure
All data is based on correct installation - see instructions No influence of edge and spacing Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d
Design resistance of resin with various stud strenghts and rebar 5.8 grade steel studding Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30 33 36
10 12 14 18 24 28 32 35 38 40
depth mm
hef failure
embedment depth 60 70 80 11.3 12.7 14.1 16.5 18.9 19.8 22.6 29.0 30.4
60
70
80
90
100
110
120
20.1 25.5 28.3 29,2 32.7 36.3 39.9 43.6 34.2 38.0 41.8 45.6 39.5 43.5 47.4 48.9 53.3 59.3
90
100
110
120
130
47.2 49.4 51.4 57.8 64.2 67.4 130
140
50.8 53.2 55.3 62.2 69.1 72.6 76.0 140
160
54.4 60.8 63.2 71.1 79.0 82.9 86.9 160
200
76.0 79.0 88.9 98.9 103.7 108.6 200
32
240
84.9 94.8 106.7 118.5 124.4 130.3 240
280
110.6 124.5 138.3 145.2 152.0 280
320
122.4 142.2 158.1 165.9 173.7 320
400
480
540
600
159.1 194.5 207.4 240.6 217.2 260.6 283.2 400 480 540 600
660
660
720
720
Fd,s design load
(mm)
(kN)
67 85 103 150 223 310 358 394 464 522
12.7 20.1 29.2 54.4 84.9 122.4 159.1 194.5 240.6 283.2
chemical anchors
chemical anchors
Vorpa VE 100 PURE EPOXY High performance pure epoxy chemical anchor with European Technical Assesment for cracked concrete, post installed and reinforcing rebars technical data
cracked concrete
reinforced concrete
natural stone
solid brick
Design resistance of resin with various stud strenghts and rebar Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30 33 36
10 12 14 18 24 28 32 35 38 40
8.8 grade steel studding
60 70 80 11.3 13.2 15.1 14.1 16.5 18.9 19.8 22.6 29.0 30.4
60
depth mm
Ø
Ø
stud
hole
hef failure
embedment depth
70
80
90 17.0 21.2 25.5 32.7 34.2
90
100 18.9 23.6 28.3 36.3 38.0 39.5
100
110 19.5 25.9 31.1 39.9 41.8 43.5 48.9
110
120
130
28.3 33.9 43.6 45.6 47.4 53.3 59.3
30.6 36.8 47.2 49,4 51.4 57.8 64.2 67.4
120
130
140 30.9 39.6 50.8 53.2 55.3 62.2 69.1 72.6 76.0 140
160 45.0 58.1 60.8 63.2 71.1 79.0 82.9 86.9 160
200
72.6 76.0 79.0 88.9 98.8 103.7 108.6 200
240
83.7 91.2 94.8 106.7 118.5 124.4 130.3 240
280
106.5 110.6 124.5 138.3 145.2 152.0 280
320
121.7 126.4 142.2 158.1 165.9 173.7 320
400
130.7 158.1 177.8 197.6 207.4 217.2 400
480
188.3 213.4 237.1 248.8 260.6 480
540
240.0 266.7 280.0 293.2 540
600
244.8 296.4 311.1 325.8 600
660
720
299.2 342.2 370.1 358.3 390.9 660 720
10.9 grade steel studding
(mm)
(mm)
8 10 12 16 20 24 27 30 33 36
10 12 14 18 24 28 32 35 38 40
60 70 80 11.3 13.2 15.1 14.1 16.5 18.9 19.8 22.6 29.0 30.4
60
depth mm
Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30 33 36
10 12 14 18 24 28 32 35 38 40
80
90
100 18.9 23.6 28.3 36.3 38.0 39.5
110 20.7 25.9 31.1 39.9 41.8 43.5 48.9
120 22.6 28.3 33.9 43.6 45.6 47.4 53.3 59.3
130 24.5 30.6 36.8 47.2 49.4 51.4 57.8 64.2 67.4
100
110
120
130
140 26.4 33.0 39.6 50.8 53.2 55.3 62.2 69.1 72.6 76.0 140
160 27.2 37.7 45.2 58.1 60.8 63.2 71.1 79.0 82.9 86.9 160
200 43.1 56.6 72.6 76.0 79.0 88.9 98.8 103.7 108.6 200
240 62.6 87.1 91.2 94.8 106.7 118.5 124.4 130.3 240
280
101.6 106.5 110.6 124.5 138.3 145.2 152.0 280
320
116.6 121.7 126.4 142.2 158.1 165.9 173.7 320
400
152.1 158.1 177.8 197.6 207.4 217.2 400
480
189.7 213.4 237.1 248.8 260.6 480
540
600
660
720
70
80
90 21.2 25.5 32.7 34.2
90
19.5 30.9 45.0 83.7 130.7 188.3 244.8 299.2 370.1 435.7
100 21.7 28.3 36.3 38.0 39.5
100
(mm)
144 183 221 321 479 664 240.0 767 266.7 296.4 844 280.0 311.1 342.2 994 293.2 325.8 358.3 390.9 1118 540 600 660 720 hef failure
embedment depth 60 70 80 11.3 13.2 13.7 14.1 16.5 18.9 19.8 22.6 29.0 30.4
(kN)
104 131 159 231 344 476 551 606 714 803
hef
A-70 stainless steel studding
60
depth mm
70
90 17.0 21.2 25.5 32.7 34.2
(mm)
failure
embedment depth
110 31.1 39.9 41.8 43.5 48.9
110
120 31.6 43.6 45.6 47.4 53.3 59.3
130
47.2 49.4 51.4 57.8 64.2 67.4
120
130
140
50.8 53.2 55.3 62.2 69.1 72.6 76.0 140
160
58.1 60.8 63.2 71.1 79.0 82.9 86.9 160
200
58.8 76.0 79.0 80.2 98.1 103.7 108.6 200
240
280
320
400
480
540
600
660
720
91.2 91.7 94.8 110.6 126.4 132,1
121 130.3 143 240 280
320
400
480
540
600
660
1 1 1 1 720
Fd,s design load
Fd,s design load
(kN)
27.2 43.1 62.6 116.6 182.0 262.2 341.0 416.7 515.5 606.9
Fd,s design load
(mm)
(kN)
73 92 112 162 241 334 181 199 234 263
13.7 21.7 31.6 58.8 91.7 132.1 80.2 98.1 121.3 142.8
*1 = tensile strenght 500N/mm2
Ø
Ø
stud
hole
High bond reinforcing bars Fyk = 800 N/mm2
hef failure
embedment depth (mm)
(mm)
8 10 12 16 20 25 28 32 36 40
12 14 16 20 25 30 35 40 44 50
depth mm
60 70 80 90 100 8.4 9.8 11.2 12.6 14.0 10.5 12.2 14.0 15.7 17.5 13.2 15.1 17.0 18.9 19.0 21.4 23.7 20.4 22.9 25.5 29.9
60
70
80
90
100
110 15.4 19.2 20.7 26.1 28.0 32.9 34.6
120 16.8 20.9 22.6 28.5 30.6 35.9 37.7
130 18.2 22.7 24.5 30.9 33.1 38.9 40.8 46.7
140 19.6 24.4 26.4 33.2 35.7 41.9 44.0 50.3 56.6
110
120
130
140
160 21.9 27.9 30.2 38.0 40.0 47.9 50.3 57.5 64.6 67.0 160
200 34.1 37.7 47.5 51.0 59.8 62.8 71.8 80.8 83.8 200
33
240 45.2 57.0 61.2 71.8 75.4 86.2 97.0 100.5 240
280 49.2 66.5 71.4 83.8 88.0 100.5 113.1 117.3 280
320
76.0 81.6 95.8 100.5 114.9 129.3 134.1 320
400
102.0 119.7 125.7 143.6 161.6 167.6 400
500
149.6 157.1 179.5 202.0 209.5 500
560
640
720
800
(mm)
157 196 261 368 536 657 176.0 852 201.1 229.8 974 226.2 258.5 290.9 1098 234.6 268.1 301.6 335.1 1304 560 640 720 800
Fd,s design load
(kN)
21.9 34.1 49.2 87.4 136.6 196.5 267.8 349.7 443.5 546.3
chemical anchors
chemical anchors
Vorpa VE 100 PURE EPOXY High performance pure epoxy chemical anchor with European Technical Assesment for cracked concrete, post installed and reinforcing rebars technical data
cracked concrete
reinforced concrete
natural stone
solid brick
Characteristic and Design Load resistances based on characteristic bond strengths for hef 4d (minimum embedment) to 20d
Cracked concrete
Non cracked concrete Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
27
30
33
36
Tension (Nrk) 20,36 27,14 54,29 25,45 38,17 84,82 35,63 55,98 122,15 52,28 81,68 209,10 67,86 128,18 301,59 82,94 174,17 398,10 102,64 223,93 503,85 124,41 290,28 622,04 141,51 326,57 718,45 169,65 384,53 814,30
Shear (Vrk)
9,00
15,00
21,00
39,00
61,00
88,00
115,00
142,50
173,50
212,50
Design Resistance Recommended Load (kN) (kN) Tension (Nrd) 11,31 15,08 30,16 14,14 21,21 47,12 19,79 31,10 67,86 29,04 45,38 116,17 32,31 61,04 143,62 39,49 82,94 189,57 48,87 106,63 239,93 59,24 138,23 296,21 67,39 155,51 342,12 80,78 183,11 387,76
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
92,00
114,00
138,80
170,00
Tension (Nrec)
Characteristic Resistance (kN)
Shear (Vrec)
8,08 10,77 21,54 10,10 15,15 33,66 14,14 22,22 48,47 20,74 32,41 82,98 23,08 43,60 102,58 28,21 59,24 135,41 34,91 76,17 171,38 42,32 98,74 211,58 48,13 111,08 244,37 57,70 130,79 276,97
Tension (Nrk)
Shear (Vrk)
Design Resistance Recommended Load (kN) (kN) Tension (Nrd)
Shear (Vrd)
Tension (Nrec)
Shear (Vrec)
5,14 Not applicable
Not applicable
Not applicable
8,57 18,47 28,00 63,33 24,13 39,20 96,51 31,10 58,96 138,23 37,70 78,37 180,96 46,65 96,29 229,02 56,55 119,00 282,74 64,02 130,63 325,01 76,34 146,12 366,44
12,00
22,29
34,86
50,29
65,71
81,43
99,14
121,43
21,00
39,00
61,00
88,00
115,00
142,50
173,50
212,50
10,26 15,56 35,19 13,40 21,78 53,62 14,81 28,08 65,82 17,95 37,32 86,17 22,22 45,85 109,06 26,93 56,67 134,64 30,48 62,20 154,77 36,35 69,6 174,49
16,80
31,20
48,80
70,40
92,00
114,00
138,80
170,00
7,33 11,11 25,13 9,57 15,56 38,30 10,58 20,06 47,02 12,82 26,66 61,55 15,87 32,75 77,90 19,23 40,48 96,17 21,77 44,43 110,55 25,97 49,70 124,64
12,00
22,29
34,86
50,29
65,71
81,43
99,14
121,43
Nominal Embedment
(mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 110 240 540 120 280 600 130 300 660 150 340 720
All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C
Bond Strength Factors Influence of concrete strength on combined pull out and concrete cone resistance (threaded bar) Concrete Strength N/mm2 (Mpa) cracked fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.98
1.00
1.02
1.04
1.06
1.08
1.09
1.10
Influence of environmental conditions in non cracked concrete (threaded bar)
Temp I 40°C/24°C
Temp II 60°C/43°C
Temp III 72°C/43°C
M8
M10
M12
M16
M20
M24
M27
M30
M33
M36
Dry and Wet
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
Allagato
1.00
0.94
0.87
0.79
0.71
0.65
0.65
0.60
0.57
0.55
Dry and Wet
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
Allagato
0.65
0.63
0.61
0.59
0.57
0.54
0.52
0.50
0.48
0.46
Dry and Wet
0.57
0.56
0.54
0.53
0.52
0.51
0.50
0.48
0.47
0.46
Allagato
0.57
0.54
0.52
0.51
0.50
0.49
0.47
0.45
0.44
0.42
34
chemical anchors
chemical anchors
Vorpa VE 100 PURE EPOXY High performance pure epoxy chemical anchor with European Technical Assesment for cracked concrete, post installed and reinforcing rebars technical data
cracked concrete
reinforced concrete
natural stone
solid brick
Bond Strength Factors Influence of environmental conditions in cracked concrete (threaded bar)
Temp I 40°C/24°C
Temp II 60°C/43°C
Temp III 72°C/43°C
M8
M10
M12
M16
M20
M24
M27
M30
M33
M36
Dry and Wet
n/a
n/a
0.50
0.48
0.46
0.45
0.43
0.41
0.40
0.38
Allagato
n/a
n/a
0.50
0.42
0.38
0.38
0.32
0.28
0.24
0.20
Dry and Wet
n/a
n/a
0.32
0.31
0.30
0.29
0.28
0.27
0.26
0.25
Allagato
n/a
n/a
0.32
0.29
0.28
0.27
0.25
0.23
0.22
0.20
Dry and Wet
n/a
n/a
0.27
0.27
0.26
0.25
0.25
0.24
0.23
0.20
Allagato
n/a
n/a
0.27
0.27
0.26
0.25
0.25
0.24
0.23
0.22
Characteristic and Design Load resistances REBAR based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Cracked concrete
Non cracked concrete Characteristic Resistance (kN) Ø mm
8
10
12
14
16
18
20
22
25
28
32
Tension (Nrk) 15,08 20,11 40,21 18,85 28,27 62,83 23,75 37,32 81,43 30,78 44,25 107,73 34,18 53,41 136,72 37,32 69,98 167,95 45,24 85,45 201,06 55,29 105,06 243,29 62,83 131,95 314,16 73,89 184,73 369,45 96,51 241,27 482,55
Shear (Vrk)
13,95
21,45
31,05
42,45
55,50
69,66
86,55
104,01
135,00
168,75
220,95
Design Resistance Recommended Load (kN) (kN) Tension (Nrd) 8,38 11,17 22,34 10,47 15,71 34,91 13,19 20,73 45,24 17,10 24,58 59,85 18,99 29,67 75,96 20,73 38,88 93,13 21,54 40,69 95,74 26,33 50,03 115,85 29,92 62,83 149,60 35,19 87,96 175,93 45,96 114,89 229,79
Shear (Vrd)
9,30
14,30
20,70
28,30
37,00
46,44
57,70
69,34
90,00
112,50
147,30
Tension (Nrec) 5,98 7,98 15,96 7,48 11,22 24,93 9,42 14,81 32,31 12,21 17,56 42,75 13,56 21,19 54,25 14,81 27,77 66,65 15,39 29,07 68,39 18,81 35,73 82,75 21,37 44,88 106,86 25,13 62,83 125,66 32,83 82,07 164,13
Shear (Vrec)
Characteristic Resistance (kN) Tension (Nrk)
Shear (Vrk)
Design Resistance Recommended Load (kN) (kN) Tension (Nrd)
Shear (Vrd)
Tension (Nrec)
Shear (Vrec)
6,64 Not applicable
Not applicable
Not applicable
10,21 13,19 20,73 45,24 16,71 22,56 58,50 18,10 25,10 72,38 19,23 31,50 86,52 22,62 37,60 100,53 25,29 45,18 114,04 27,49 56,73 137,45 34,48 77,60 172,41 45,04 98,92 225,19
14,79
20,21
26,43
33,17
41,21
49,53
64,29
80,36
105,21
31,05
42,45
55,50
69,66
86,55
104,00
135,00
168,75
220,95
7,33 11,52 25,13 9,29 12,54 32,50 10,05 13,94 40,21 10,68 17,50 48,07 10,77 17,90 47,87 12,34 21,51 54,30 13,09 27,02 65,45 16,42 36,95 82,10 21,45 47,10 107,23
20,70
28,10
37,00
46,44
57,70
69,34
90,00
112,50
147,30
5,24 8,23 17,95 6,63 8,96 23,21 7,18 9,96 28,72 7,63 12,50 34,33 7,69 12,79 34,19 8,82 15,37 38,79 9,35 19,30 46,75 11,73 26,39 58,64 15,32 33,65 76,60
14,79
20,07
26,43
33,17
41,21
49,53
64,29
80,36
105,21
Nominal Embedment
(mm) 60 80 160 60 90 200 70 110 240 80 115 280 80 125 320 80 150 360 90 170 400 100 190 440 100 210 500 112 280 560 128 320 640
All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C
35
chemical anchors
chemical anchors
Vorpa VE 100 PURE EPOXY High performance pure epoxy chemical anchor with European Technical Assesment for cracked concrete, post installed and reinforcing rebars technical data
cracked concrete
reinforced concrete
natural stone
solid brick
Bond Strength Factors Influence of concrete strength on combined pull out and concrete cone resistance (rebar) Concrete Strength N/mm2 (Mpa) cracked fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
C55/67
C60/75
C70/85
C80/96
C90/105
0.98
1.00
1.02
1.04
1.06
1.08
1.09
1.10
1.10
1.12
1.13
1.14
1.15
Influence of environmental conditions in non cracked concrete (rebar)
Temp I 40°C/24°C
Temp II 60°C/43°C
Temp III 72°C/43°C
Ø8
Ø 10
Ø 12
Ø 14
Ø 16
Ø 18
Ø 20
Ø 22
Ø 25
Ø 28
Ø 32
Dry and Wet
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
Allagato
1.00
0.94
0.90
0.87
0.85
0.82
0.80
0.76
0.71
0.65
0.63
Dry and Wet
0.67
0.65
0.63
0.63
0.62
0.62
0.61
0.61
0.60
0.60
0.59
Allagato
0.65
0.64
0.61
0.60
0.59
0.59
0.58
0.57
0.56
0.55
0.47
Dry and Wet
0.60
0.58
0.57
0.57
0.56
0.56
0.56
0.55
0.55
0.54
0.53
Allagato
0.58
0.56
0.53
0.52
0.50
0.47
0.47
0.46
0.45
0.43
0.41
Influence of environmental conditions in cracked concrete (threaded bar)
Temp I 40°C/24°C
Temp II 60°C/43°C
Temp III 72°C/43°C
Ø8
Ø 10
Ø 12
Ø 14
Ø 16
Ø 18
Ø 20
Ø 22
Ø 25
Ø 28
Ø 32
Dry and Wet
n/a
n/a
0.55
0.51
0.47
0.45
0.44
0.43
0.43
0.42
0.41
Allagato
n/a
n/a
0.55
0.48
0.42
0.41
0.40
0.39
0.38
0.36
0.35
Dry and Wet
n/a
n/a
0.30
0.29
0.28
0.27
0.26
0.25
0.24
0.23
0.23
Allagato
n/a
n/a
0.30
0.28
0.27
0.26
0.25
0.24
0.23
0.22
0.22
Dry and Wet
n/a
n/a
0.30
0.28
0.26
0.25
0.25
0.24
0.24
0.23
0.22
Allagato
n/a
n/a
0.30
0.28
0.26
0.25
0.24
0.24
0.23
0.23
0.22
Examples of applications
36
chemical anchors
chemical anchors
Vorpa VE 100 PURE EPOXY High performance pure epoxy chemical anchor with European Technical Assesment for cracked concrete, post installed and reinforcing rebars technical data Effect of anchor spacing - Tension Spacing (mm) 40 50 60 70 80 90 100 120 150 160 175 200 225 240 250 275 280 300 320 350 400 440 480 540 600 660 720 800
10 0,63 0,65 0,67 0,69 0,72 0,74 0,79 0,86 0,88 0,92 1,00
12
0,63 0,64 0,66 0,68 0,70 0,74 0,80 0,82 0,85 0,90 0,95 1,00
16
0,63 0,64 0,65 0,68 0,73 0,74 0,76 0,80 0,84 0,86 0,87 0,91 0,92 0,95 1,00
20
0,63 0,65 0,68 0,70 0,71 0,74 0,77 0,79 0,80 0,83 0,84 0,86 0,88 0,92 1,00
24
27
30
0,63 0,65 0,66 0,67 0,69 0,72 0,73 0,74 0,76 0,77 0,79 0,81 0,83 0,88 0,92 1,00
0,63 0,64 0,65 0,66 0,69 0,71 0,72 0,73 0,75 0,76 0,78 0,80 0,82 0,87 0,91 0,94 1,00
24
27
30
0,35 0,51 0,63 0,75 0,88 1,00
0,30 0,35 0,46 0,57 0,68 0,78 1,00
0,63 0,63 0,64 0,66 0,68 0,69 0,70 0,72 0,73 0,74 0,76 0,78 0,82 0,85 0,88 0,93 1,00
33
36
(mm) 40 50 60 70 80 90 100 110 120 140 160 180 200 220 240 270 300 330 360 400
40
0,63 0,63 0,65 0,67 0,68 0,69 0,71 0,71 0,73 0,74 0,77 0,80 0,83 0,86 0,91 0,96 1,00
0,63 0,63 0,65 0,67 0,68 0,68 0,70 0,70 0,72 0,73 0,75 0,78 0,81 0,84 0,88 0,92 0,96 1,00
0,63 0,63 0,65 0,66 0,67 0,68 0,69 0,69 0,71 0,72 0,73 0,76 0,79 0,81 0,84 0,88 0,91 0,95 1,00
33
36
40
0,32 0,37 0,46 0,56 0,65 0,84 1,00
0,33 0,43 0,50 0,56 0,63 0,77 0,90 1,00
Edge distances Stud/rebar diameter 8 0,25 0,44 0,63 0,81 1,00
10 0,30 0,48 0,65 0,83 1,00
12
0,30 0,44 0,58 0,72 0,86 1,00
natural stone
solid brick
Edge distances Stud/rebar diameter
Effect of edge distance - Shear
(mm) 40 50 60 70 80 90 100 110 125 140 160 180 200 220 240 280 310 330 400
reinforced concrete
Effect of edge distance - Tension
Stud/rebar diameter 8 0,64 0,67 0,70 0,73 0,76 0,79 0,82 0,87 0,96 1,00
cracked concrete
16
0,40 0,53 0,67 0,80 1,00
20
0,35 0,44 0,58 0,72 0,91 1,00
0,35 0,46 0,62 0,77 0,92 1,00
0,32 0,53 0,59 0,72 0,82 0,89 1,00
37
8 0,64 0,73 0,82 0,90 1,00
10 0,63 0,70 0,77 0,84 0,91 1,00
12
0,63 0,68 0,74 0,80 0,86 0,92 1,00
16
0,63 0,67 0,71 0,76 0,80 0,89 1,00
20
0,63 0,66 0,70 0,77 0,84 0,91 1,00
24
0,64 0,67 0,72 0,78 0,84 0,89 1,00
27
30
0,63 0,70 0,75 0,81 0,86 0,92 1,00
0,63 0,65 0,70 0,76 0,81 0,86 0,94 1,00
33
36
0,63 0,66 0,71 0,75 0,80 0,87 0,94 1,00
0,67 0,71 0,74 0,78 0,82 0,87 0,93 0,98 1,00
40
0,68 0,71 0,75 0,78 0,83 0,88 0,93 0,98 1,00
chemical anchors
chemical anchors
Vorpa VSM - Fixing in seismic C1+C2 High performance styrene free vinylester chemical anchor with European Technical Assesment for cracked concrete, post installed rebars and seismic zone products group
cracked concrete
Approved for • cracked and non-cracked concrete under seismic action C1 (M8-M30 and rebar Ø8Ø32mm) C2 (M12-M20) • post installated rebar nstallation Ø8-Ø32mm • masonry use category b, c, d M8-M16
reinforced concrete
natural stone
solid brick
perforated brick
To fix • structural fixings • heavy duty metal structures • heavy structural works • construction joints • scaffolding links • wall ties, starter bars, studs, bolts & large screws • electric installations plumbing
Also suitable for • natural stone • solid brick • perforated brick
ato per Certific smica + si l’area d for Certifie area seismic
FIXING IN SEISMIC
C1+C2
VSM 300
CALCULATION SOFTWARE
Styrene Free
VSM 400
Tested for LEED FIRE RATED compliancy
EAD 330499-00-0601 for cracked and non cracked concrete and seismic action M8-M30 / Ø8-Ø32mm rebar Seismic action C2- M12, M16, M20
EAD 330076-00-0604 M8-M16 for use in masonry cat.b,c,d
EAD 330087-00-0601 Ø8-Ø32mm post-installed rebar Fire resistance in ETA for postinstalled rebar
product code Code
1142 1144
Description
VSM 300 VSM 400
Content ml
Gun to be used
Shelf life
300 420
silicon type coaxial
18 months 18 months
Store upright
Examples of applications
38
chemical anchors
chemical anchors
Vorpa VSM - Fixing in seismic C1+C2 High performance styrene free vinylester chemical anchor with European Technical Assesment for cracked concrete, post installed rebars and seismic zone product information Characteristics • vinylester styrene free chemical anchoring injection system with very high bond strength, developed principally to anchor threaded rods and rebar into concrete • european Technical Assessment for structural use in cracked concrete • approved for seismic applications with performance category C1 and C2 • suitable for high loads within standard annulus and embedment • fast working times for early loading in time sensitive applications • no styrene allows for use indoors and in enclosed spaces • use in wet or flooded environments and fixing holes • high durability, resistance to chemicals • used for studs and rebar • may be used as crack ang gap filling resin
cracked concrete
reinforced concrete
natural stone
solid brick
perforated brick
Approval/certifications/testing • EAD 330499-00-0601 M8 - M30 Threaded rod and Rebar • EAD 330087-00-0601 Ø8 - Ø32 Rebar post-installed + Fire test • EAD 330076-00-0604 M8 - M16 Hollow wall / Masonry installation • Fire Test Report in ETA for post-installed rebar • ICC-ES Approval ESR 4366 Cracked and Non-Cracked • Wras Approved for use with Potable drinking water approval no. 1811567 • LEED tested 2009 EQ c4.1 SCAQMD rule 1168 (2005) • VOC A+ Rating (Volatile Organic Content) Suggestion for use • performance based on clean holes. • HAMMER DRILLED – blown and then brushed with a stiff metal brush and blown again
installation sequence Clean the hole before the installation
On solid brick
technical data Physical Properties Compressive Strength Flexural Strength E Modulus VOC Content
N/mm2 (MPa)
Test Method
100 15 14.000 A+
EN 196 PARTE 1 EN 196 PARTE 1 EN 196 PARTE 1 -
Minimum Curing Time Concrete Temperature
Gel-working Time
-10°C to -6°C* -5°C to -1°C* 0°C to +4°C°* +5°C to +9°C +10°C to +19°C +20°C to +29°C +30°C + 34°C +35°C to +40°C
90 min 90 min 45 min 25 min 15 min 6 min 4 min 2 min
Temperature Ranges Minimum curing Minimum curing time time in dry concrete in wet concrete 24 h 14 h 7h 2h 80 min 45 min 25 min 20 min
x2 x2 x2 x2 x2 x2 x2 x2
Range
Concrete Service Temperature
Maximum Long Term Concrete Temperature
Maximum Short Term Concrete Temperature
Range I Range II Range III
-40°C to +40°C -40°C to +80°C -40°C to +120°C
+24°C +50°C +72°C
+40°C +80°C +120°C
Service temperature range: Range of ambient temperatures after installation and during the lifetime of the anchor. Short term temperature: Temperature within the service temperature range which vary over short intervals, e.g. day/night cycles and freeze/than cycles. Long term temperature: Temperature, within the service temperature range, which will be approximately constant over significant periods of time.
* resin temperature must be at least +20°C Full cure 24 hours All specifications based on supplied mixer Store at temperatures between +5 and +25 degrees, away from direct heat, rain and moisture
39
chemical anchors
chemical anchors
Vorpa VSM - Fixing in seismic C1+C2 High performance styrene free vinylester chemical anchor with European Technical Assesment for cracked concrete, post installed rebars and seismic zone technical data
cracked concrete
reinforced concrete
natural stone
solid brick
perforated brick
Loads, Edge and Spacings based on Characteristic bond strengths - Showing steel failure with 5.8 grade studding and associated installation data Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
27
30
33
36
Tension (Nrk)
Shear (Vrk)
19,00 19,00 19,00 27,33 30,20 30,20 38,27 43,80 43,80 58,31 81,60 81,60 82,00 127,40 127,40 94,10 183,60 183,60 112,00 238,00 238,00 124,40 290,30 292,00 134,80 311,00 360,00 152,70 346,10 425,00
9,00
15,00
21,00
39,00
61,00
88,00
115,00
142,50
173,50
212,50
Design Resistance Recommended Load Characteristic distances (kN) (kN) (mm)
Min Edge and Spacing
Tension (Nrd)
(mm) (Cmin Smin)
12,70 12,70 12,70 15,18 20,10 20,10 21,26 29,20 29,20 32,39 54,40 54,40 45,56 84,90 84,90 52,28 122,40 122,40 62,22 159,10 159,10 69,11 161,28 194,50 74,89 172,78 240,60 84,83 192,28 283,33
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
92,00
114,00
138,80
170,00
Tension (Nrec) 9,07 9,07 9,07 10,85 14,36 14,36 15,19 20,86 20,86 23,14 38,86 38,86 25,00 60,64 60,64 30,77 87,43 87,43 44,44 113,64 113,64 49,37 115,20 138,93 53,49 123,41 171,86 60,60 137,34 202,38
Shear (Vrec)
Edge Spacing Edge (Ccr,N) (Scr,N) (Ccr,V)
5,14
80
160
80
40
8,57
100
200
90
50
1,40 12,00
120
240
110
60
22,29
160
320
125
80
34,86
200
400
180
100
50,29
230
460
220
120
65,71
270
540
240
135
81,43
280
560
280
150
121,43
310
620
310
165
121,43
330
660
330
180
Hole Max Nominal Hole Embedment diameter diameter Torque concrete fixture (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 96 210 480 110 240 540 120 280 600 130 300 660 150 340 720
(mm)
(mm)
(Nm)
10
9
10
12
12
20
14
14
40
18
18
80
24
22
120
28
26
160
30
30
180
35
33
200
37
36
250
40
38
300
Steel failure All data is based on correct installation - see instructions No influence of edge and spacing Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d
Design resistance of resin with various stud strenghts and rebar 5.8 grade steel studding Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30 33 36
10 12 14 18 24 28 32 35 38 40
depth mm
hef failure
embedment depth 60 70 80 90 12.7 15.2 17.7 20.1 21.3 24.3 27.3 32.4 36.4 40.5 45.6
60
70
80
90
100
110
120
130
29.2 40.5 44.5 48.6 52.6 50.6 55.7 60.7 65.8 54.5 59.9 65.4 70.8 62.2 67.9 73.5 69.1 74.9 74.9 100
110
120
130
140
54.4 70.9 76.2 79.2 80.6 80.6 79.2 140
160
81.0 87.1 90.5 92.2 92.2 90.5 160
200
84.9 108.9 113.1 115.2 115.2 113.1 200
40
240
122.4 135.7 138.2 138.2 135.7 240
280
158.4 161.3 161.3 158.4 280
320
159.1 184.3 184.3 181.0 320
400
480
540
600
660
195 230.4 240.6 251.4 271.5 271.5 283,2 400 480 540 600 660
720
720
Fd,s design load
(mm)
(kN)
56 79 96 134 168 225 281 338 418 501
12.7 20.1 29.2 54.4 84.9 122.4 159.1 194.5 240.6 283.2
chemical anchors
chemical anchors
Vorpa VSM - Fixing in seismic C1+C2 High performance styrene free vinylester chemical anchor with European Technical Assesment for cracked concrete, post installed rebars and seismic zone technical data
cracked concrete
reinforced concrete
natural stone
Design resistance of resin with various stud strenghts and rebar
solid brick
perforated brick
Steel failure
8.8 grade steel studding Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30 33 36
10 12 14 18 24 28 32 35 38 40
hef 60 70 80 13.6 15.8 18.1 15.2 17.7 20.2 21.3 24.3 32.4 40.5
60
depth mm
failure
embedment depth
70
80
90 19.5 22.8 27.3 36.4 45.6
90
100 25.3 30.4 40.5 50.6 54.5
100
110 27.8 33.4 44.5 55.7 59.9 62.2
110
120
130
30.4 36.4 48.6 60.7 65.4 67.9 69.1
30.9 39.5 52.6 65.8 70.8 73.5 74.9 74.9
120
130
140 42.5 56.7 70.9 76.2 79.2 80.6 80.6 79.2 140
160 45.0 64.8 81.0 87.1 90.5 92.2 92.2 90.5 160
200
81.0 101.2 108.9 113.1 115.2 115.2 113.1 200
240
83.7 121.5 130.7 135.7 138.2 138.2 135.7 240
280
130.7 152.5 158.4 161.3 161.3 158.4 280
320
174.3 181.0 184.3 184.3 181.0 320
400
188.3 226.2 230.4 230.4 226.2 400
480
244.8 276.5 276.5 271.5 480
540
600
660
720
299.2 311.1 345.6 370.1 305.4 339.3 373.3 407.2 540 600 660 720
Fd,s design load
(mm)
(kN)
86 122 148 207 258 346 433 519 643 770
19.5 30.9 45.0 83.7 130.7 188.3 244.8 299.2 370.1 435.7
A-70 stainless steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30 33 36
10 12 14 18 24 28 32 35 38 40
depth mm
hef failure
embedment depth 60 70 80 13.6 13.7 15.2 17.7 20.2 21.3 24.3 32.4 40.5
60
70
80
90
100
110
120
21.7 27.3 30.4 31.6 36.4 40.5 44.5 48.6 45.6 50.6 55.7 60.7 54.5 59.9 65.4 62.2 67.9 69.1
90
100
110
120
130
52.6 65.8 70.8 73.5 74.9 74.9 130
140
56.7 70.9 76.2 79.2 80.6 80.6 79.2 140
160
58.8 81.0 87.1 80.2 92.2 92.2 90.5 160
200
240
280
320
400
480
540
600
660
720
91.7 108.9 130.7 132.1 98.1 115.2 121.3 113.1 135.7 142.8 200 240 280 320
400
480
540
600
660
1 1 1 1 720
Fd,s design load
(mm)
(kN)
61 86 104 145 181 243 142 170 211 253
13.7 21.7 31.6 58.8 91.7 132.1 80.2 98.1 121.3 142.8
*1 = tensile strenght 500N/mm2
High bond reinforcing bars Fyk = 500 N/mm2 Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 25 28 32 36 40
12 14 16 20 25 30 35 40 44 50
depth mm
hef failure
embedment depth 60 70 80 9.2 10.8 12.3 13.6 15.9 18.2 19.1 21.8 29.0 31.1
60
70
80
90 13.8 20.4 24.5 32.7 35.0
90
100 15.4 22.7 27.2 36.3 38.9 44.9
100
110 16.9 25.0 30.0 39.9 42.8 49.4 50.7
110
120 18.4 27.2 32.7 43.6 46.7 53.9 55.3
120
130 20.0 29.5 35.4 47.2 50.6 58.4 59.9 59.1
140 21.5 31.8 38.1 50.8 54.5 62.8 64.5 63.7 67.9
130
140
160 21.9 34.1 43.6 58.1 62.2 71.8 73.7 72.8 77.6 86.2 160
200 49.2 72.6 77.8 89.8 92.2 91.0 97.0 107.7 200
41
240
87.1 93.4 107.7 110.6 109.2 116.3 129.3 240
280
87.4 108.9 125.7 129.0 127.4 135.7 150.8 280
320
124.5 143.6 147.5 145.5 155.1 172.4 320
400
136.6 179.5 184.3 181.9 193.9 215.5 400
500
196.5 230.4 227.4 242.4 269.3 500
560
258.1 254.7 271.5 301.6 560
640
720
800
291.1 310.3 349.0 344.7 387.8 430.9 640 720 800
Fd,s design load
(mm)
(kN)
142 150 181 241 351 438 581 769 915 1014
21.9 34.1 49.2 87.4 136.6 196.5 267.8 349.7 443.5 546.3
chemical anchors
chemical anchors
Vorpa VSM - Fixing in seismic C1+C2 High performance styrene free vinylester chemical anchor with European Technical Assesment for cracked concrete, post installed rebars and seismic zone technical data
cracked concrete
reinforced concrete
natural stone
solid brick
perforated brick
Characteristic and Design Load resistances based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non cracked concrete Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
27
30
33
36
Tension (Nrk) 20,36 27,15 54,30 27,33 41,00 91,10 38,26 60,12 131,20 58,30 91,10 233,20 82,00 154,90 364,40 94,10 205,84 470,50 112,00 244,30 549,70 124,40 290,30 622,00 134,80 311,00 684,40 152,70 346,20 733,00
Shear (Vrk)
9,00
15,00
21,00
39,00
61,00
88,00
115,00
142,50
173,50
212,50
Cracked concrete
Design Resistance Recommended Load (kN) (kN) Tension (Nrd) 13,57 18,10 36,20 15,18 22,78 50,61 21,26 33,40 72,89 32,39 50,61 129,56 45,56 86,06 202,444 52,28 114,36 261,39 62,22 135,72 305,39 69,11 161,28 345,56 74,89 172,78 380,22 84,83 192,33 407,22
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
92,00
114,00
138,80
170,00
Tension (Nrec)
Characteristic Resistance (kN)
Shear (Vrec)
9,70 12,93 25,86 10,85 16,27 35,39 15,18 23,86 52,06 23,13 36,15 92,54 32,54 61,47 144,60 37,34 81,68 186,71 44,44 96,94 218,13 49,37 115,20 246,83 53,49 123,41 271,59 60,60 137,38 290,87
Tension (Nrk) 9,05 12,07 24,14 13,20 19,80 44,00 19,80 31,10 67,85 30,16 47,13 120,65 42,41 80,11 188,50 54,29 118,75 271,45 79,31 173,03 389,35 96,13 224,31 480,66 114,56 264,37 581,60 144,20 326,85 692,16
5,14
8,57
12,00
22,29
34,86
50,29
65,71
81,43
99,14
121,43
Shear (Vrk)
9,00
15,00
21,00
39,00
61,00
88,00
115,00
142,50
173,50
212,50
Design Resistance Recommended Load (kN) (kN) Tension (Nrd) 6,03 8,05 16,09 7,33 11,00 24,44 11,00 17,28 37,69 16,76 26,18 67,03 23,56 44,51 104,72 30,16 65,97 150,81 44,06 96,13 216,31 53,41 124,62 267,04 63,64 146,87 323,11 80,11 181,58 384,53
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
92,00
114,00
138,80
170,00
Tension (Nrec) 4,31 5,75 11,50 5,24 7,86 17,46 7,86 12,34 26,92 11,97 18,70 47,88 16,83 31,79 74,80 21,54 47,12 107,72 31,47 68,66 154,50 38,15 89,01 190,74 45,46 104,91 230,79 57,22 129,70 274,66
Shear (Vrec)
5,14
8,57
12,00
22,29
34,86
50,29
65,71
81,43
99,14
121,43
Nominal Embedment
(mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 110 240 540 120 280 600 130 300 660 150 340 720
All data is based on correct installation - see instructions. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C
Bond Strength Factors Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) non cracked fc= cracked fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.98 0.98
1.00 1.00
1.02 1.02
1.04 1.04
1.07 1.07
1.08 1.08
1.09 1.09
1.10 1.10
Influence of environmental conditions in non cracked concrete
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
M8
M10
M12
M16
M20
M24
M27
M30
M33
M36
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.75
0.75
0.75
0.75
0.75
0.77
0.75
0.72
0.72
0.72
Influence of environmental conditions in cracked concrete
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
M8
M10
M12
M16
M20
M24
M27
M30
M33
M36
0.40
0.42
0.46
0.46
0.46
0.50
0.65
0.72
0.72
0.72
0.25
0.29
0.33
0.33
0.33
0.36
0.45
0.50
0.50
0.50
42
chemical anchors
chemical anchors
Vorpa VSM - Fixing in seismic C1+C2 High performance styrene free vinylester chemical anchor with European Technical Assesment for cracked concrete, post installed rebars and seismic zone technical data
cracked concrete
reinforced concrete
natural stone
solid brick
perforated brick
Characteristic and Design Load resistances for REBAR based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non cracked concrete Characteristic Resistance (kN) Ø mm
8
10
12
14
16
18
20
22
25
28
32
Tension (Nrk)
Shear (Vrk)
16,58 22,11 44,21 24,49 36,74 81,64 34,29 53,88 117,56 45,72 65,72 160,01 52,25 81,64 209,00 58,78 110,21 264,51 73,48 138,79 326,56 82,90 157,50 364,74 94,20 197,82 471,00 108,32 270,79 541,59 122,18 305,46 610,92
13,95
21,45
31,05
42,45
55,50
69,66
86,55
104,01
135,00
168,75
220,95
Cracked concrete
Design Resistance Recommended Load (kN) (kN) Tension (Nrd) 11,05 14,74 29,47 13,61 20,41 45,36 19,05 29,93 65,31 25,40 36,51 88,90 29,03 45,36 116,11 32,66 61,23 146,95 40,82 77,10 181,42 46,05 87,50 202,63 52,33 109,90 261,67 60,18 150,44 300,88 67,88 169,70 339,40
Shear (Vrd)
9,30
14,30
20,70
28,30
37,00
46,44
57,70
69,34
90,00
112,50
147,30
Tension (Nrec) 7,89 10,53 21,05 9,72 14,58 32,40 13,61 21,38 46,65 18,14 26,08 63,50 20,73 32,40 82,94 23,33 43,74 104,97 29,16 55,07 129,59 32,90 62,50 144,74 37,38 78,50 186,90 42,98 107,46 214,92 48,49 121,21 242,43
Characteristic Resistance (kN)
Shear (Vrec)
Tension (Nrk)
Shear (Vrk)
7,54 10,05 20,10 11,30 16,96 37,68 17,14 26,94 58,78 22,86 32,86 80,01 26,12 40,82 104,50 29,39 55,11 132,26 36,74 69,39 163,28 44,90 85,31 197,57 51,03 107,15 255,13 73,85 184,63 369,26 96,46 241,15 482,30
6,64
10,21
14,79
20,21
26,43
33,17
41,21
49,53
64,29
80,36
105,21
13,95
21,45
31,05
42,45
55,50
69,66
86,55
104,00
135,00
168,75
220,95
Design Resistance Recommended Load (kN) (kN) Tension (Nrd) 5,02 6,70 13,40 6,28 9,42 20,93 9,52 14,97 32,66 12,70 18,26 44,45 14,51 22,68 58,06 16,33 30,62 73,48 20,41 38,55 90,71 24,95 47,40 109,76 28,35 59,53 141,74 41,03 102,57 205,15 53,59 133,97 267,95
Shear (Vrd)
9,30
14,30
20,70
28,10
37,00
46,44
57,70
69,34
90,00
112,50
147,30
Tension (Nrec) 3,59 4,78 9,57 4,49 6,73 14,95 6,80 10,69 23,33 9,07 13,04 31,75 10,37 16,20 41,47 11,66 21,87 52,48 14,58 27,54 64,79 17,82 33,85 78,40 20,25 42,52 101,24 29,31 73,27 146,53 38,28 95,70 191,39
Shear (Vrec)
6,64
10,21
14,79
20,07
26,43
33,17
41,21
49,53
64,29
80,36
105,21
Nominal Embedment
(mm) 60 80 160 60 90 200 70 110 240 80 115 280 80 125 320 80 150 360 90 170 400 100 190 440 100 210 500 112 280 560 128 320 640
All data is based on correct installation - see instructions. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C
Bond Strength Factors Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) non cracked fc= cracked fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.98 0.98
1.00 1.00
1.02 1.02
1.04 1.04
1.07 1.07
1.08 1.08
1.09 1.09
1.10 1.10
Influence of environmental conditions in non cracked concrete
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
Ø8
Ø10
Ø12
Ø14
Ø16
Ø18
Ø20
Ø22
Ø25
Ø28
Ø32
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.73
0.73
0.70
0.70
43
chemical anchors
chemical anchors
Vorpa VSM - Fixing in seismic C1+C2 High performance styrene free vinylester chemical anchor with European Technical Assesment for cracked concrete, post installed rebars and seismic zone technical data
cracked concrete
reinforced concrete
natural stone
solid brick
perforated brick
Influence of environmental conditions in cracked concrete
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
Ø8
Ø10
Ø12
Ø14
Ø16
Ø18
Ø20
Ø22
Ø25
Ø28
Ø32
0.40
0.42
0.46
0.46
0.46
0.46
0.46
0.50
0.50
0.65
0.76
0.25
0.30
0.33
0.33
0.33
0.33
0.33
0.36
0.36
0.45
0.53
Effect of anchor spacing - Tension Anchor spacing (mm) (mm) 40 50 60 70 80 90 100 120 150 160 180 200 225 240 250 275 280 300 320 350 400 440 460 500 540 560 620 660 720
Effect of edge distance - Tension Anchor spacing
Stud/Rebar diameter 8 0,64 0,67 0,70 0,73 0,76 0,79 0,82 0,87 0,96 1,00
10
0,63 0,65 0,67 0,69 0,72 0,74 0,79 0,86 0,88 0,93 1,00
12
0,63 0,64 0,66 0,68 0,70 0,74 0,80 0,82 0,86 0,90 0,95 1,00
16
0,63 0,64 0,65 0,68 0,73 0,74 0,77 0,80 0,84 0,86 0,87 0,91 0,92 0,95 1,00
20
0,63 0,65 0,68 0,70 0,72 0,74 0,77 0,79 0,80 0,83 0,84 0,86 0,88 0,92 1,00
24
0,63 0,65 0,66 0,68 0,69 0,72 0,73 0,74 0,76 0,77 0,79 0,81 0,83 0,88 0,92 1,00
27
0,64 0,65 0,65 0,67 0,69 0,71 0,72 0,74 0,75 0,76 0,78 0,81 0,86 0,89 0,91 0,95 1,00
30
0,63 0,63 0,65 0,66 0,68 0,69 0,70 0,72 0,73 0,74 0,76 0,78 0,82 0,85 0,87 0,90 0,93 1,00
33
0,62 0,64 0,65 0,67 0,69 0,70 0,72 0,72 0,74 0,75 0,78 0,82 0,85 0,87 0,90 0,93 0,95 100
36
0,64 0,65 0,67 0,68 0,68 0,70 0,70 0,72 0,73 0,75 0,78 0,81 0,82 0,85 0,88 0,89 0,93 1,00
(mm) 40 50 60 70 80 90 100 110 120 140 160 180 200 220 240 270 280 310 330 360
40
0,63 0,64 0,65 0,66 0,67 0,68 0,69 0,69 0,71 0,72 0,73 0,76 0,79 0,80 0,82 0,84 0,86 0,89 0,91 1,00
Stud/Rebar diameter 8 0,64 0,73 0,82 0,90 1,00
10 0,63 0,70 0,77 0,84 0,91 1,00
12
0,63 0,68 0,74 0,80 0,86 0,92 1,00
16
0,63 0,67 0,71 0,76 0,80 0,89 1,00
20
0,63 0,66 0,70 0,77 0,84 0,91 1,00
24
0,64 0,67 0,72 0,78 0,84 0,89 1,00
27
30
0,63 0,70 0,75 0,81 0,86 0,92 1,00
0,63 0,65 0,66 0,76 0,81 0,86 0,94 1,00
27
30
0,44 0,57 0,69 0,82 0,94 1,00
0,30 0,35 0,46 0,57 0,68 0,78 1,00
33
0,62 0,70 0,76 0,81 0,86 0,94 0,97 1,00
36
40
0,67 0,78 0,82 0,87 0,93 0,96 0,98 1,00
0,68 0,71 0,75 0,78 0,83 0,85 0,90 0,93 1,00
36
40
Effect of edge distance - Shear Anchor spacing (mm) 40 50 60 70 80 90 100 110 125 140 160 180 200 220 240 280 310 330 360
44
Stud/Rebar diameter 8 0,25 0,44 0,63 0,81 1,00
10 0,30 0,48 0,65 0,83 1,00
12
0,30 0,44 0,58 0,72 0,86 1,00
16
0,40 0,53 0,67 0,80 1,00
20
0,35 0,44 0,58 0,72 0,91 1,00
24
0,35 0,46 0,62 0,77 0,92 1,00
33
0,34 0,41 0,50 0,59 0,68 0,86 1,00
0,33 0,42 0,51 0,60 0,78 0,91 1,00
0,32 0,53 0,59 0,72 0,82 0,89 1,00
chemical anchors
chemical anchors
Vorpa VSF CE High performance styrene free vinylester chemical anchor with European Technical Assesment for cracked concrete, post installed and reinforcing rebars products group
cracked concrete
Approved for • cracked concrete M12-M16 • non cracked concrete M8-M24, rebar Ø8-Ø25 • post installated rebar installation Ø8-Ø16 Also suitable for • natural stone • solid brick • wood
reinforced concrete
natural stone
CALCULATION SOFTWARE
VSF 300 VSF 400
Tested for LEED compliancy ETAG 01-01 TR023 Ø8-Ø16mm post-installed rebar
ETAG 001-05 M8-M24 threaded bars/ Ø8-Ø25mm rebars for non cracked concrete
ETAG 001-05 M12-M16 threaded bars for cracked concrete
product code Code
Description
1160 1008 1120
VSF 300 VSF 345 VSF 400
Content ml
Gun to be used
Shelf life
300 345 400
silicone type side by side 3:1 coaxial
18 months 18 months 18 months
Store upright
Examples of applications
45
wood
To fix • structural fixings • heavy duty metal structures • heavy structural works • construction joints • scaffolding links • wall ties, starter bars, studs,bolts & large screws • electric installations plumbing
i per ferr Ideale presa da ri for le Suitab rebars ing reinforc
VSF 345
solid brick
Styrene Free
FIRE RATED
chemical anchors
chemical anchors
Vorpa VSF CE High performance styrene free vinylester chemical anchor with European Technical Assesment for cracked concrete, post installed and reinforcing rebars product information Characteristics • vinylester styrene free chemical anchoring injection system with very high bond strength, developed principally to anchor threaded rods and rebar into concrete • european Technical Assessment for structural use in cracked concrete • high bond strength with high load resistance • used in dry and wet concrete, critical or overhead applications • used in corrosive environments • low shrinkage enables large diameter installations • close edge distance and small spacing, high chemical resistance
cracked concrete
reinforced concrete
natural stone
solid brick
wood
Approval/certifications/testing • 12/0125 – ETA Option 1 - M12 and M16 for Cracked Concrete • 12/0125 – ETA Option 7 - M8 to M24, Rebar Ø8 to Ø25 for noncracked concrete • 14/0167 –ETA TR023 Post Installed Rebar Installation Ø8-Ø16 • Fire Test Report SIGGMA • WRAS Approved for use with Potable drinking water approval n.1501531 • LEED tested 2009 EQ c4.1 SCAQMD rule 1168 (2005) • VOC A+ Rating (Volatile Organic Content) Suggestion for use • performance based on clean holes. • HAMMER DRILLED – blown and then brushed with a stiff metal brush and blown again
installation sequence Clean the hole before the installation
On solid brick
technical data Physical Properties Compressive Strength Flexural Strength Flexural Modulus Tensile Strength E Modulus VOC Content
N/mm2 (MPa)
Test Method
73,0 25,0 3850,0 14,6 8029,7 A+
EN ISO 604 / ASTM 695 EN ISO 178 / ASTM 790 EN ISO 178 / ASTM 790 EN ISO 527 / ASTM 638 EN ISO 527 / ASTM 638 -
Minimum Curing Time Concrete Temperature
-10°C * -5°C * 5°C 15°C 25°C 35°C
Temperature Ranges
Gel-working Minimum curing Minimum curing time Time time in dry concrete in wet concrete
50 min 40 min 20 min 9 min 5 min 3 min
240 min 180 min 90 min 60 min 30 min 20 min
x2 x2 x2 x2 x2 x2
Range
Concrete Service Maximum Long Term Maximum Short Term Temperature Concrete Temperature Concrete Temperature
Range I Range II
-40°C to +40°C -40°C to +80°C
+24°C +50°C
+40°C +80°C
Service temperature range: Range of ambient temperatures after installation and during the lifetime of the anchor. Short term temperature: Temperature within the service temperature range which vary over short intervals, e.g. day/night cycles and freeze/than cycles. Long term temperature: Temperature, within the service temperature range, which will be approximately constant over significant periods of time.
* resin temperature must be at least +20°C Full cure 24 hours All specifications based on supplied mixer Store at temperatures between +5 and +25 degrees, away from direct heat, rain and moisture
46
chemical anchors
chemical anchors
Vorpa VSF CE High performance styrene free vinylester chemical anchor with European Technical Assesment for cracked concrete, post installed and reinforcing rebars technical data
cracked concrete
reinforced concrete
natural stone
solid brick
wood
Typical characteristic and design resistance performance with 5.8 grade studding and associated installation data
Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
27
30
33
36
Tension (Nrk)
Shear (Vrk)
19,00 19,00 19,00 22,62 30,20 30,20 29,82 43,80 43,80 43,43 67,86 81,60 55,42 104,68 127,40 63,33 133,00 183,60 70,91 154,72 238,00 78,04 182,09 292,00 88,95 205,27 360,00 108,57 246,10 425,00
9,00
15,00
21,00
39,00
61,00
88,00
115,00
142,50
173,50
212,50
Design Resistance Recommended Load Characteristic distances (kN) (kN) (mm)
Min Edge and Spacing
Tension (Nrd)
(mm) (Cmin Smin)
12,70 12,70 12,70 15,08 20,10 20,10 19,88 29,20 29,20 28,95 45,24 54,40 36,95 69,79 84,90 42,22 88,67 122,40 47,27 103,15 159,10 52,02 121,39 194,50 59,30 136,85 240,60 72,38 164,07 283,33
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
92,00
114,00
138,80
170,00
Tension (Nrec) 9,07 9,07 9,07 10,77 14,36 14,36 14,20 20,86 20,86 20,68 32,31 38,86 26,39 49,85 60,64 30,16 63,33 87,43 33,77 73,68 113,64 37,16 86,71 138,93 42,36 97,75 171,86 51,70 117,19 202,38
Shear (Vrec)
Edge Spacing Edge (Ccr,N) (Scr,N) (Ccr,V)
5,14
80
160
80
40
8,57
100
200
90
50
12,00
120
240
110
60
22,29
160
320
125
80
34,86
200
400
180
100
50,29
230
460
220
120
65,71
270
540
240
135
81,43
280
560
280
150
121,43
310
620
310
165
121,43
330
660
330
180
Nominal Hole Hole Max Embedment diameterdiameter Torque concrete fixture (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 110 240 540 120 280 600 130 300 660 150 340 720
(mm)
(mm)
(Nm)
10
9
10
12
12
20
14
14
40
18
18
80
24
22
120
28
26
160
32
30
180
35
32
200
37
36
250
40
38
300
= Steel failure
All data is based on correct installation - see instructions No influence of edge and spacing Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d
Design resistance of resin with various stud strenghts and rebar 5.8 grade steel studding Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30 33 36
10 12 14 18 24 28 32 35 38 40
depth mm
hef failure
embedment depth 60 70 80 90 12.7 15.1 17.6 20.1 19.9 22.7 25.6 29.0 32.6 32.8 36.9
60
70
80
90
100 28.4 36.2 41.1 42.2
100
110 29,2 39.8 45.2 46.5 47.3
110
120
130
43.4 49.3 50.7 51.6 52.0
47.1 53.4 54.9 55.9 56.4 59.3
120
130
140
50.7 57.5 59.1 60.2 60.7 63.9 67.6 140
160
54.4 65.7 67.6 68.8 69.4 73.0 77.2 160
200
82.1 84.5 86.0 86.7 91.2 96.5 200
47
240
84.9 101.3 103.2 104.1 109.5 115.8 240
280
118.2 120.3 121.4 127.7 135.1 280
320
122.4 137.5 138.8 146.0 154.4 320
400
159.1 173.4 182.5 193.0 400
480
540
600
660
194.5 219.0 240.6 231.6 260.6 283.2 480 540 600 660
720
720
Fd,s design load
(mm)
(kN)
59 80 103 150 207 290 370 449 527 587
12.7 20.1 29.2 54.4 84.9 122.4 159.1 194.5 240.6 283.2
chemical anchors
chemical anchors
Vorpa VSF CE High performance styrene free vinylester chemical anchor with European Technical Assesment for cracked concrete, post installed and reinforcing rebars technical data
cracked concrete
reinforced concrete
natural stone
solid brick
wood
Design resistance of resin with various stud strenghts and rebar Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30 33 36
10 12 14 18 24 28 32 35 38 40
8.8 grade steel studding
60 70 80 12.9 15.0 17.2 15.1 17.6 20.1 19.9 22.7 29.0 32.8
60
depth mm
Ø
Ø
stud
hole
hef failure
embedment depth
70
80
90 19.3 22.6 25.6 32.6 36.9
90
100 19.5 25.1 28.4 36.2 41.1 42.2
100
110 27.6 31.2 39.8 45.2 46.5 47.3
110
120 30.2 34.1 43.4 49.3 50.7 51.6 52.0
130 30.9 36.9 47.1 53.4 54.9 55.9 56.4 59.3
120
130
140 39.8 50.7 57.5 59.1 60.2 60.7 63.9 67.6 140
160 45.0 57.9 65.7 67.6 68.8 69.4 73.0 77.2 160
200
72.4 82.1 84.5 86.0 86.7 91.2 96.5 200
240
83.7 98.5 101.3 103.2 104.1 109.5 115.8 240
280
114.9 118.2 120.3 121.4 127.7 135.1 280
320
130.7 135.1 137.5 138.8 146.0 154.4 320
400
168.9 171.9 173.4 182.5 193.0 400
480
188.3 206.3 208.1 219.0 231.6 480
540
232.1 234.1 246.4 260.6 540
600
660
720
260.2 273.7 301.1 289.5 318.5 347.4 600 660 720
10.9 grade steel studding
(mm)
(mm)
8 10 12 16 20 24 27 30 33 36
10 12 14 18 24 28 32 35 38 40
60 70 80 12.9 15.0 17.2 15.1 17.6 20.1 19.9 22.7 29.0 32.8
60
depth mm
Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30 33 36
10 12 14 18 24 28 32 35 38 40
Ø
Ø
stud
hole
80
90
100 21.4 25.1 28.4 36.2 41.1 42.2
110 23.6 27.6 31.2 39.8 45.2 46.5 47.3
120 25.7 30.2 34.1 43.4 49.3 50.7 51.6 52.0
130 27.2 32.7 36.9 47.1 53.4 54.9 55.9 56.4 59.3
100
110
120
130
140 35.2 39.8 50.7 57.5 59.1 60.2 60.7 63.9 67.6 140
160 40.2 45.4 57.9 65.7 67.6 68.8 69.4 73.0 77.2 160
200 43.1 56.8 72.4 82.1 84.5 86.0 86.7 91.2 96.5 200
240 62.6 86.9 98.5 101.3 103.2 104.1 109.5 115.8 240
280
101.3 114.9 118.2 120.3 121.4 127.7 135.1 280
320
115.8 131.4 135.1 137.5 138.8 146.0 154.4 320
400
116.6 164.2 168.9 171.9 173.4 182.5 193.0 400
480
202.7 206.3 208.1 219.0 231.6 480
540
600
660
720
70
80
90
100
100
failure
110
120
110
130
47.1 53.4 54.9 55.9 56.4 59.3
120
130
140
50.7 57.5 59.1 60.2 60.7 63.9 67.6 140
160
57.9 65.7 67.6 68.8 69.4 73.0 77.2 160
200
58.8 82.1 84.5 80.2 86.7 91.2 96.5 200
240
280
320
400
480
540
600
660
720
91.7 101.3 118.2 132.1 98.1 109.5 121 115.8 135.1 143 240 280 320
400
480
540
600
660
(mm)
8 10 12 16 20 25 28 32 36 40
10 12 15 20 25 30 35 40 44 50
High bond reinforcing bars Fyk = 500 N/mm2
depth mm
60 70 80 8.7 10.2 11.7 10.4 12.1 13.8 13.7 15.7 19.3 21.0
60
70
80
90 13.1 15.6 17.6 21.7 23.6
90
110 16.0 19.0 21.6 26.5 28.9 31.1 33.4
120 17.5 20.7 23.5 29.0 31.5 33.9 36.4
130 19.0 22.5 25.5 31.4 34.1 36.8 39.5 43.1
140 20.4 24.2 27.4 33.8 36.7 39.6 42.5 46.5 52.3
100
110
120
130
140
160 21.9 27.6 31.4 38.6 42.0 45.2 48.6 53.1 59.7 66.4 160
200 34.1 39.2 48.3 52.5 56.6 60.7 66.4 74.7 82.9 200
48
240 47.1 57.9 63.0 67.9 72.8 79.6 89.6 99.5 240
49.2 67.6 73.5 79.2 85.0 92.9 104.5 116.1 280
320
77.2 84.0 90.5 97.1 106.2 119.4 132.7 320
400
105.0 113.1 121.4 132.7 149.3 165.9 400
500
141.4 151.8 165.9 186.6 207.4 500
560
640
720
Fd,s design load
(kN)
64 86 111 162 223 313 187 226 266 296
13.7 21.7 31.6 58.8 91.7 132.1 80.2 98.1 121.3 142.8
failure
280
(kN)
27.2 43.1 62.6 116.6 182.0 262.2 341.0 416.7 515.5 606.9
(mm)
hef
100 14.6 17.3 19.6 24.1 26.2 28.3
Fd,s design load
720
embedment depth (mm)
(mm)
hef
21.7 25.6 28.4 31.2 31.6 32.6 36.2 39.8 43.4 36.9 41.1 45.2 49.3 42.2 46.5 50.7 47.3 51.6 52.0
90
19.5 30.9 45.0 83.7 130.7 188.3 244.8 299.2 370.1 435.7
127 171 220 322 443 621 232.1 793 234.1 260.2 961 246.4 273.7 301.1 1130 260.6 289.5 318.5 347.4 1258 540 600 660 720
embedment depth 60 70 80 12.9 13.7 15.1 17.6 20.1 19.9 22.7 29.0 32.8
(kN)
91 123 158 231 318 446 570 690 811 903
hef
A-70 stainless steel studding
60
depth mm
70
90 19.3 22.6 25.6 32.6 36.9
(mm)
failure
embedment depth
Fd,s design load
800
(mm)
150 198 251 362 521 695 170.0 882 185.8 212.3 1054 209.0 238.9 268.8 1188 232.3 265.4 298.6 331.8 1317 560 640 720 800
Fd,s design load
(kN)
21.9 34.1 49.2 87.4 136.6 196.5 267.8 349.7 443.5 546.3
chemical anchors
chemical anchors
Vorpa VSF CE High performance styrene free vinylester chemical anchor with European Technical Assesment for cracked concrete, post installed and reinforcing rebars technical data
cracked concrete
reinforced concrete
natural stone
solid brick
wood
Characteristic and Design Load resistances based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non cracked concrete Characteristic Resistance (kN) Ø mm
Tension (Nrk)
Shear (Vrk)
Cracked concrete
Design Resistance Recommended Load (kN) (kN) Tension (Nrd)
Shear (Vrd)
Tension (Nrec)
Characteristic Resistance (kN)
Shear (Vrec)
Tension (Nrk)
Shear (Vrk)
Design Resistance Recommended Load (kN) (kN) Tension (Nrd)
Shear (Vrd)
Tension (Nrec)
Shear (Vrec)
Nominal Embedment
(mm)
19,30 12,87 9,19 60 Not applicable Not applicable Not applicable 25,74 9,00 17,16 7,20 12,26 5,14 80 51,47 34,31 24,51 160 22,62 15,08 10,77 10,40 6,94 4,96 60 10 33,93 15,00 22,62 12,00 16,16 8,57 15,60 15,00 10,40 12,00 7,43 8,57 90 75,40 50,27 35,90 34,68 23,12 16,52 200 29,82 19,88 14,20 13,12 8,75 6,24 70 12 46,86 21,00 31,24 16,80 22,31 12,00 20,62 21,00 13,75 16,80 9,82 12,00 110 102,24 68,16 48,69 44,98 29,98 21,42 240 43,43 28,95 20,68 17,37 11,58 8,27 80 16 67,86 39,00 45,24 31,20 32,31 22,29 27,14 39,00 18,10 31,20 12,93 22,29 125 173,72 115,81 82,72 69,50 46,33 33,10 320 55,42 36,95 26,39 21,06 14,04 10,00 90 20 104,68 61,00 69,79 48,80 49,85 34,86 39,78 61,00 26,52 48,80 18,94 34,86 170 246,30 164,20 117,29 93,60 62,40 44,59 400 63,33 42,22 30,16 100 24 133,00 88,00 88,67 70,40 63,33 50,29 210 304,01 202,67 144,76 480 Not applicable Not applicable Not applicable 70,91 47,27 33,77 110 27 154,72 115,00 103,15 92,00 73,68 65,71 240 348,11 232,08 165,77 540 78,04 52,02 37,16 120 30 182,09 142,50 121,39 114,00 86,71 81,43 280 390,19 260,12 185,80 600 Not applicable Not applicable Not applicable 88,95 59,30 42,36 130 33 205,27 173,50 136,85 138,80 97,75 99,14 300 451,60 301,07 215,05 660 108,57 72,38 51,70 150 36 246,10 212,50 164,07 170,00 117,19 121,43 340 Not applicable Not applicable Not applicable 521,15 347,44 248,17 720 All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C 8
Bond Strength Factors Influence of concrete strength on combined pull out and concrete cone resistance (threaded bar) Concrete Strength N/mm2 (Mpa) non cracked fc= cracked fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.94 0.96
1.00 1.00
1.06 1.03
1.12 1.05
1.17 1.06
1.23 1.07
1.26 1.08
1.30 1.09
Influence of environmental conditions in non cracked concrete (threaded bar)
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
M8
M10
M12
M16
M20
M24
M27
M30
M33
M36
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.90
0.88
0.87
0.86
0.85
0.84
0.83
0.82
0.81
0.80
Influence of environmental conditions in cracked concrete (threaded bar)
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
M8
M10
M12
M16
M20
M24
M27
M30
n/a
0.46
0.44
0.40
0.38
n/a
n/a
n/a
n/a
0.45
0.43
0.40
0.38
n/a
n/a
n/a
49
chemical anchors
chemical anchors
Vorpa VSF CE High performance styrene free vinylester chemical anchor with European Technical Assesment for cracked concrete, post installed and reinforcing rebars technical data
cracked concrete
reinforced concrete
natural stone
solid brick
wood
Characteristic and Design Load resistances REBAR based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non cracked concrete Characteristic Resistance (kN) Ø mm
8
10
12
14
16
18
20
22
25
28
32
Tension (Nrk)
Shear (Vrk)
15,68 20,91 41,82 18,66 27,99 62,20 24,70 38,82 84,69 31,67 45,52 110,84 34,74 54,29 138,97 37,55 70,40 168,97 36,76 69,43 163,36 44,92 85,36 197,67 51,05 107,21 255,26 61,08 152,71 305,41 77,21 193,02 386,04
13,95
21,45
31,05
42,45
55,50
69,66
86,55
104,01
135,00
168,75
220,95
Cracked concrete
Design Resistance Recommended Load (kN) (kN) Tension (Nrd) 8,71 11,62 23,23 10,37 15,55 34,56 13,72 21,56 47,05 17,59 25,29 61,58 19,30 30,16 77,21 20,86 39,11 93,87 20,42 38,57 90,76 24,96 47,42 109,82 28,36 59,56 141,81 33,93 84,84 169,67 42,89 107,23 214,47
Shear (Vrd)
9,30
14,30
20,70
28,30
37,00
46,44
57,70
69,34
90,00
112,50
147,30
Tension (Nrec) 6,22 8,30 16,60 7,41 11,11 24,68 9,80 15,40 33,61 12,57 18,06 43,98 13,79 21,54 55,15 14,90 27,94 67,05 14,59 27,55 64,83 17,83 33,87 78,44 20,26 42,54 101,29 24,24 60,60 121,20 30,64 76,60 153,19
Characteristic Resistance (kN)
Shear (Vrec)
Tension (Nrk)
Shear (Vrk)
Design Resistance Recommended Load (kN) (kN) Tension (Nrd)
Shear (Vrd)
Tension (Nrec)
Shear (Vrec)
6,64 Not applicable
Not applicable
Not applicable
10,21 10,56 16,59 36,19 13,72 19,73 48,03 15,28 23,88 61,12 16,51 30,96 74,31 19,79 37,39 87,96 24,19 45,96 106,44 27,49 57,73 137,45
14,79
20,21
26,43
33,17
41,21
49,53
64,29
31,05
42,45
55,50
69,66
86,55
104,00
135,00
5,86 9,22 20,11 7,62 10,96 26,68 8,49 13,26 33,96 9,17 17,20 41,28 11,00 20,77 48,87 13,44 25,53 59,13 15,27 32,07 76,36
20,70
28,10
37,00
46,44
57,70
69,34
90,00
4,19 6,58 14,36 5,45 7,83 19,06 6,06 9,47 24,26 6,55 12,29 29,49 7,85 14,84 34,91 9,60 18,24 42,24 10,91 22,91 54,54
14,79
20,07
26,43
33,17
41,21
49,53
64,29
80,36 Not applicable
Not applicable
Not applicable
105,21
Nominal Embedment
(mm) 60 80 160 60 90 200 70 110 240 80 115 280 80 125 320 80 150 360 90 170 400 100 190 440 100 210 500 112 280 560 128 320 640
All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C
Bond Strength Factors Influence of concrete strength on combined pull out and concrete cone resistance (rebar) Concrete Strength N/mm2 (Mpa) non cracked fc= cracked fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.94 0.96
1.00 1.00
1.06 1.03
1.12 1.05
1.17 1.06
1.23 1.07
1.26 1.08
1.30 1.09
Influence of environmental conditions in non cracked concrete (rebar)
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
Ø8
Ø 10
Ø 12
Ø 14
Ø 16
Ø 18
Ø 20
Ø 22
Ø 25
Ø 28
Ø 32
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.53
1.00
1.00
1.00
0.90
0.90
0.88
0.88
0.88
0.86
0.86
0.56
0.86
0.84
0.84
50
chemical anchors
chemical anchors
Vorpa VSF CE High performance styrene free vinylester chemical anchor with European Technical Assesment for cracked concrete, post installed and reinforcing rebars technical data
cracked concrete
reinforced concrete
natural stone
solid brick
wood
Influence of environmental conditions in cracked concrete (rebar)
Dry and Wet Dry and Wet
Temp I 40°C/24°C Temp II 80°C/50°C
Ø8
Ø 10
Ø 12
Ø 14
Ø 16
Ø 18
Ø 20
Ø 22
Ø 25
Ø 28
Ø 32
n/a
n/a
0.50
0.43
0.50
0.43
0.50
0.53
0.50
n/a
n/a
n/a
n/a
0.44
0.38
0.44
0.38
0.43
0.46
0.43
n/a
n/a
Effect of anchor spacing - Tension Spacing (mm) 40 50 60 70 80 90 100 120 150 160 180 200 225 240 250 275 280 300 320 350 400 440 460 500 540 560 620 660 720
Effect of edge distance - Tension Edge distances (mm) 40 50 60 70 80 90 100 110 120 140 160 180 200 220 240 270 280 310 330 360
Stud/rebar diameter 8 0,64 0,67 0,70 0,73 0,76 0,79 0,82 0,87 0,96 1,00
10 0,63 0,65 0,67 0,69 0,72 0,74 0,79 0,86 0,88 0,93 1,00
12
0,63 0,64 0,66 0,68 0,70 0,74 0,80 0,82 0,86 0,90 0,95 1,00
16
0,63 0,64 0,65 0,68 0,73 0,74 0,77 0,80 0,84 0,86 0,87 0,91 0,92 0,95 1,00
20
0,63 0,65 0,68 0,70 0,72 0,74 0,77 0,79 0,80 0,83 0,84 0,86 0,88 0,92 1,00
24
0,63 0,65 0,66 0,68 0,69 0,72 0,73 0,74 0,76 0,77 0,79 0,81 0,83 0,88 0,92 1,00
27
0,64 0,65 0,65 0,67 0,69 0,71 0,72 0,74 0,75 0,76 0,78 0,81 0,86 0,89 0,91 0,95 1,00
30
0,63 0,63 0,65 0,66 0,68 0,69 0,70 0,72 0,73 0,74 0,76 0,78 0,82 0,85 0,87 0,90 0,93 1,00
33
0,62 0,64 0,65 0,67 0,69 0,70 0,72 0,72 0,74 0,75 0,78 0,82 0,85 0,87 0,90 0,93 0,95 1,00
36
0,64 0,65 0,67 0,68 0,68 0,70 0,70 0,72 0,73 0,75 0,78 0,81 0,82 0,85 0,88 0,89 0,93 1,00
40
0,63 0,64 0,65 0,66 0,67 0,68 0,69 0,69 0,71 0,72 0,73 0,76 0,79 0,80 0,82 0,84 0,86 0,89 0,91 1,00
Stud/rebar diameter 8 0,64 0,73 0,82 0,90 1,00
10 0,63 0,70 0,77 0,84 0,91 1,00
12
0,63 0,68 0,74 0,80 0,86 0,92 1,00
16
0,63 0,67 0,71 0,76 0,80 0,89 1,00
20
0,63 0,66 0,70 0,77 0,84 0,91 1,00
24
0,64 0,67 0,72 0,78 0,84 0,89 1,00
27
30
0,63 0,70 0,75 0,81 0,86 0,92 1,00
0,63 0,65 0,66 0,76 0,81 0,86 0,94 1,00
27
30
0,44 0,57 0,69 0,82 0,94 1,00
0,30 0,35 0,46 0,57 0,68 0,78 1,00
33
0,62 0,70 0,76 0,81 0,86 0,94 0,97 1,00
36
40
0,67 0,78 0,82 0,87 0,93 0,96 0,98 1,00
0,68 0,71 0,75 0,78 0,83 0,85 0,90 0,93 1,00
36
40
Effect of edge distance - Shear Edge distances (mm) 40 50 60 70 80 90 100 110 125 140 160 180 200 220 240 280 310 330 360
51
Stud/rebar diameter 8 0,25 0,44 0,63 0,81 1,00
10 0,30 0,48 0,65 0,83 1,00
12
0,30 0,44 0,58 0,72 0,86 1,00
16
0,40 0,53 0,67 0,80 1,00
20
0,35 0,44 0,58 0,72 0,91 1,00
24
0,35 0,46 0,62 0,77 0,92 1,00
33
0,34 0,41 0,50 0,59 0,68 0,86 1,00
0,33 0,42 0,51 0,60 0,78 0,91 1,00
0,32 0,53 0,59 0,72 0,82 0,89 1,00
chemical anchors
chemical anchors
Vorpa VIN Styrene free vinylester eco chemical anchor derived from epoxy acrylate resin with European Technical Assesment for non cracked concrete, post installed rebars and masonry products group
concrete
Approved for • non cracked concrete M8-M24, rebar Ø8-Ø25mm • masonry and hollow wall M6M12 • post installed rebar Ø8-Ø12mm
natural stone
solid brick
perforated brick
To fix • heavy duty metal structures • heavy duty structural works • construction joints • scaffolding links • wall ties, starter bars, studs, bolts & large screws
Also suitable for • perforated brick • natural stone
filettate er barre Ideale p calcestruzzo su ed thread le for Suitab in concrete bars
CALCULATION SOFTWARE
VIN 300 VIN 400
Tested for LEED compliancy EAD 330499-00-0601 for non cracked concrete M8-M24 threaded bar Ø8-Ø25mm rebar
EAD 330076-00-0604 EAD 330087-00-0601 for masonry and non cracked Ø8-Ø12mm post-installed concrete rebar conncection M6-M12 threaded bar Fire resistance in ETA for post-installed rebar
product code Code
Description
1148 1149
VIN 300 VIN 400
Content ml
Gun to be used
Shelf life
300 410
silicone type coaxial
18 months 18 months
Store upright
Examples of applications
52
Styrene Free
FIRE RATED
chemical anchors
chemical anchors
Vorpa VIN Styrene free vinylester eco chemical anchor derived from epoxy acrylate resin with European Technical Assesment for non cracked concrete, post installed rebars and masonry product information Characteristics • vinylester eco styrene free chemical anchoring injection system with very high bond strength, developed to anchor threaded rods and rebar into concrete • European Technical Assessment for use in non-cracked concrete, hollow wall/masonry and post installed rebar • suitable for high loads within standard annulus and embedment • fast working times for early loading in time sensitive applications • no styrene allows for use indoors and in enclosed spaces • use in wet or flooded environments and fixing holes • good durability formulation, resistance to chemicals • approved for studs and rebar in non-cracked concrete and postinstalled Rebar • 10:1 resin available in a variety of cartridge types • fixing in concrete, wood, or other high strength materials
concrete
natural stone
solid brick
perforated brick
Approval/certifications/testing • EAD 330499-00-0601 M8-M24 Threaded rods and Rebar for non cracked concrete • EAD 330087-00-0601 8-12mm Rebar Post-Installed • EAD 330076-00-0804 M6-M12 Hollow Wall/Masonry Installations • Fire Test Report in ETA for post-installed rebar • WRAS Approved for use with Potable drinking water approval no. 1501531 • LEED tested 2009 EQ c4.1 SCAQMD rule 1168 (2005) • VOC A+ Rating (Volatile Organic Content) • Suggestion for use • performance based on clean holes. • HAMMER DRILLED – blown and then brushed with a stiff metal brush and blown again
installation sequence Clean the hole before the installation
On solid brick
On hollow brick
technical data Minimum Curing Time
Temperature Ranges
Concrete Temperature
Gel-working Time
Minimum curing time in dry concrete
Minimum curing time in wet concrete
-10°C * -5°C * 5°C 15°C 25°C 35°C
50 min 40 min 20 min 9 min 5 min 3 min
240 min 180 min 90 min 60 min 30 min 20 min
x2 x2 x2 x2 x2 x2
Range
Concrete Service Temperature
Maximum Long Term Concrete Temperature
Maximum Short Term Concrete Temperature
Range I Range II
-40°C to +40°C -40°C to +60°C
+24°C +50°C
+40°C +80°C
Service temperature range: Range of ambient temperatures after installation and during the lifetime of the anchor. Short term temperature: Temperature within the service temperature range which vary over short intervals, e.g. day/ night cycles and freeze/than cycles. Long term temperature: Temperature, within the service temperature range, which will be approximately constant over significant periods of time.
*resin temperature must be at least 20°C Full cure 24 hours. All specifications based on supplied mixer Store at temperatures between +5 and +25 degrees, away from direct heat, rain and moisture
53
chemical anchors
chemical anchors
Vorpa VIN Styrene free vinylester eco chemical anchor derived from epoxy acrylate resin with European Technical Assesment for non cracked concrete, post installed rebars and masonry technical data Physical Properties
N/mm2 (MPa)
Test Method
41 15,4 3111,7 9,4 5488,5 A+
EN ISO 604 / ASTM 695 EN ISO 178 / ASTM 790 EN ISO 178 / ASTM 790 EN ISO 527 / ASTM 638 EN ISO 527 / ASTM 638 -
Compressive Strength Flexural Strength Flexural Modulus Tensile Strength E Modulus VOC Content
concrete
natural stone
solid brick
perforated brick
Typical characteristic and design resistance performance with 5.8 grade studding and associated installation data Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
30
Tension (Nrk)
Shear (Vrk)
18,85 19,00 19,00 23,56 30,20 30,20 31,67 43,80 43,80 48,25 75,40 81,60 65,03 122,84 127,40 82,94 174,17 183,60 93,30 203,70 238,00 101,79 237,50 292,00
9,00
15,00
21,00
39,00
61,00
88,00
115,00
142,50
Design Resistance Recommended Load Characteristic distances (kN) (kN) (mm)
Min Edge and Spacing
Tension (Nrd)
(mm) (Cmin Smin)
10,47 12,70 12,70 13,09 20,10 20,10 17,59 29,20 29,20 26,81 41,89 54,40 36,13 68,24 84,90 46,08 96,76 122,40 51,83 113,17 159,10 56,55 131,94 194,50
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
92,00
114,00
Tension (Nrec) 7,48 9,07 9,07 9,35 14,36 14,36 12,57 20,86 20,86 19,15 29,92 38,86 25,81 48,75 60,64 32,91 69,12 87,43 37,02 80,83 113,64 40,39 94,25 138,93
Shear (Vrec)
Edge Spacing Edge (Ccr,N) (Scr,N) (Ccr,V)
5,14
80
160
80
40
8,57
100
200
90
50
12,00
120
240
110
60
22,29
160
320
125
80
34,86
200
400
180
100
50,29
240
480
220
120
65,71
270
540
240
135
81,43
280
560
280
150
Nominal Hole Hole Max Embedment diameterdiameter Torque concrete fixture (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 110 240 540 120 280 600
(mm)
(mm)
(Nm)
10
9
10
12
12
20
14
14
40
18
18
80
24
22
120
28
26
160
32
30
180
35
32
200
All data is based on correct installation - see instructions No influence of edge and spacing Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d
= Steel failure
Design resistance of resin with various stud strenghts and rebar 5.8 grade steel studding Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
hef failure
embedment depth 60 70 80 10.5 12.2 12.7 13.1 15.3 17.5 17.6 20.1 26.8 32.1
60
70
80
90 19.6 22.6 30.2 36.1
90
100 20.1 25.1 33.5 40.1 46.1
100
110 27.6 36.9 44.2 50.7 51.8 110
120 29.2 40.2 48.2 55.3 56.6 56.6 120
130
43.6 52.2 59.9 61.3 61.3 130
140
46.9 56.2 64.5 66.0 66.0 140
160
53.6 64.2 73.7 75.4 75.4 160
200
54.4 80.3 92.2 94.3 94.3 200
54
240
84.9 110.6 113.1 113.1 240
280
320
400
480
540
122 132.0 150.8 159.1 132.0 150.8 188.5 194.5 280 320 400 480 540
600
600
660
660
720
720
Fd,s design load
(mm)
(kN)
73 92 116 162 212 266 338 413
12.7 20.1 29.2 54.4 84.9 122.4 159.1 194.5
chemical anchors
chemical anchors
Vorpa VIN Styrene free vinylester eco chemical anchor derived from epoxy acrylate resin with European Technical Assesment for non cracked concrete, post installed rebars and masonry technical data
concrete
natural stone
Design resistance of resin with various stud strenghts and rebar
solid brick
perforated brick
Steel failure
8.8 grade steel studding Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
hef 60 70 80 10.5 12.2 14.0 13.1 15.3 17.5 17.6 20.1 26.8 32.1
60
depth mm
failure
embedment depth
70
80
90 15.7 19.6 22.6 30.2 36.1
90
100 17.5 21.8 25.1 33.5 40.1 46.1
110 19.2 24.0 27.6 36.9 44.2 50.7 51.8
100
110
120 19.5 26.2 30.2 40.2 48.2 55.3 56.6 56.6 120
130 28.4 32.7 43.6 52.2 59.9 61.3 61.3 130
140 30.5 35.2 46.9 56.2 64.5 66.0 66.0 140
160 30.9 40.2 53.6 64.2 73.7 75.4 75.4 160
200 45.0 67.0 80.3 92.2 94.3 94.3 200
240
80.4 96.4 110.6 113.1 113.1 240
280
83.7 112.4 129.0 132.0 132.0 280
320
128.5 147.5 150.8 150.8 320
400
130.7 184.3 188.5 188.5 400
480
540
600
660
188.3 226.2 244.8 226.2 254.4 282.8 480 540 600 660
720
Fd,s design load
(mm)
(kN)
112 142 179 250 325 409 519 635
19.5 30.9 45.0 83.7 130.7 188.3 244.8 299.2
720
10.9 grade steel studding Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
embedment depth 60 70 80 10.5 12.2 14.0 13.1 15.3 17.5 17.6 20.1 26.8 32.1
60
70
80
90 15.7 19.6 22.6 30.2 36.1
90
100 17.5 21.8 25.1 33.5 40.1 46.1
110 19.2 24.0 27.6 36.9 44.2 50.7 51.8
100
110
120 20.9 26.2 30.2 40.2 48.2 55.3 56.6 56.6 120
130 22.7 28.4 32.7 43.6 52.2 59.9 61.3 61.3 130
140 24.4 30.5 35.2 46.9 56.2 64.5 66.0 66.0 140
160 27.2 34.9 40.2 53.6 64.2 73.7 75.4 75.4 160
200 43.1 50.3 67.0 80.3 92.2 94.3 94.3 200
240 60.3 80.4 96.4 110.6 113.1 113.1 240
280
93.8 112.4 129.0 132.0 132.0 280
320
107.2 128.5 147.5 150.8 150.8 320
400
160.6 184.3 188.5 188.5 400
480
540
600
660
221.2 226.2 254.5 226.2 254.5 282.8 480 540 600 660
720
hef
Fd,s
failure
design load
(mm)
(kN)
156 197 249 348 453 569 723 884
27.2 43.1 62.6 116.6 182.0 262.2 341.0 416.7
720
A-70 stainless steel studding Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
hef failure
embedment depth 60 70 80 10.5 12.2 13.7 13.1 15.3 17.5 17.6 20.1 26.8 32.1
60
70
80
90 19.6 22.6 30.2 36.1
90
100 21.7 25.1 33.5 40.1 46.1
100
110 27.6 36.9 44.2 50.7 51.8 110
120 30.2 40.2 48.2 55.3 56.6 56.6 120
130 31.6 43.6 52.2 59.9 61.3 61.3 130
140
46.9 56.2 64.5 66.0 66.0 140
160
53.6 64.2 73.7 75.4 75.4 160
200
58.8 80.3 92.2 80.2 94.3 200
240
280
320
400
480
540
600
660
720
91.7 110.6 129.0 132.1 98.1 240 280
320
400
480
540
600
660
1 1 720
Fd,s design load
(mm)
(kN)
78 100 126 175 228 287 170 208
13.7 21.7 31.6 58.8 91.7 132.1 80.2 98.1
*1 = tensile strenght 500N/mm2
High bond reinforcing bars Fyk = 500 N/mm2 Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 25 28 32
12 14 16 20 25 30 35 40
depth mm
hef failure
embedment depth 60 70 80 9.2 10.8 12.3 11.5 13.4 15.4 16.1 18.4 22.3 27.9
60
70
80
90 13.8 17.3 20.7 25.1 31.4
90
100 15.4 19.2 23.0 27.9 34.9 43.6
110 16.9 21.1 25.3 30.7 38.4 48.0 48.4
120 18.4 23.0 27.6 33.5 41.9 52.4 52.8
100
110
120
130 20.0 25.0 30.0 36.3 45.4 56.7 57.2 65.4 130
140 21.5 26.9 32.3 39.1 48.9 61.1 61.6 70.4 140
160 21.9 30.7 36.9 44.7 55.9 69.8 70.4 80.4 160
200 34.1 46.1 55.9 69.8 87.3 88.0 100.5 200
55
240 49.2 67.0 83.8 104.7 105.6 120.7 240
280
78.2 97.8 122.2 123.2 140.8 280
320
87.4 111.7 139.6 140.8 160.9 320
400
136.6 174.6 176.0 201.1 400
500
560
640
720
196.5 219.9 246.3 251.4 281.5 321.7 500 560 640 720
800
800
Fd,s design load
(mm)
(kN)
142 178 213 313 391 450 609 696
21.9 34.1 49.2 87.4 136.6 196.5 267.8 349.7
chemical anchors
chemical anchors
Vorpa VIN Styrene free vinylester eco chemical anchor derived from epoxy acrylate resin with European Technical Assesment for non cracked concrete, post installed rebars and masonry technical data
concrete
natural stone
solid brick
perforated brick
Characteristic and Design Load resistances based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non cracked concrete Characteristic Resistance (kN) Ø mm
Tension (Nrk)
Cracked concrete
Design Resistance Recommended Load (kN) (kN)
Shear (Vrk)
Tension (Nrd)
Shear (Vrd)
Tension (Nrec)
Characteristic Resistance (kN)
Shear (Vrec)
Tension (Nrk)
Design Resistance Recommended Load (kN) (kN)
Shear (Vrk)
Tension (Nrd)
Shear (Vrd)
Tension (Nrec)
Nominal Embedment
Shear (Vrec)
(mm)
18,85 10,47 7,48 60 25,13 9,00 13,96 7,20 9,97 5,14 80 Not applicable Not applicable Not applicable 50,27 27,93 19,95 160 23,56 13,09 9,35 60 10 35,34 15,00 19,63 12,00 14,02 8,57 90 Not applicable Not applicable Not applicable 78,54 43,63 31,17 200 31,67 17,59 12,57 70 12 49,76 21,00 27,65 16,80 19,75 12,00 110 Not applicable Not applicable Not applicable 108,57 60,32 43,08 240 48,25 26,81 19,15 80 16 75,40 39,00 41,89 31,20 29,92 22,29 125 Not applicable Not applicable Not applicable 193,02 107,23 76,60 320 65,03 36,13 25,81 90 20 122,84 61,00 68,24 48,80 48,74 34,86 170 Not applicable Not applicable Not applicable 289,03 160,57 114,69 400 82,94 46,08 32,91 100 24 174,17 88,00 96,75 70,40 69,12 50,29 210 Not applicable Not applicable Not applicable 398,10 221,17 157,98 480 101,79 56,55 40,39 120 Not applicable Not applicable Not applicable 30 237,50 142,50 131,95 114,00 94,25 81,43 280 508,94 282,74 201,96 600 All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C 8
Bond Strength Factors Influence of concrete strength on combined pull out and concrete cone resistance (threaded bar) Concrete Strength N/mm2 (Mpa) non cracked fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
Influence of environmental conditions in non cracked concrete (threaded bar) Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
M8
M10
M12
M16
M20
M24
M30
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.70
0.70
0.70
Effect of anchor spacing - Tension Edge distance (mm) 40 50 60 70 80 90 100 110 120 140 160 180 200 220 240 280
10 0,63 0,70 0,77 0,84 0,91 1,00
12
0,63 0,68 0,74 0,80 0,86 0,92 1,00
16
0,63 0,67 0,71 0,76 0,80 0,89 1,00
0.70
0.70
Spacing
0.70
Effect of edge distance - Shear
Stud/rebar diameter 8 0,64 0,73 0,82 0,90 1,00
0.70
Effect of edge distance - Tension
20
0,63 0,66 0,70 0,77 0,84 0,91 1,00
24
0,64 0,67 0,72 0,78 0,84 0,89 1,00
30
0,63 0,65 0,70 0,76 0,81 0,86 1,00
Edge distance (mm) 40 50 60 70 80 90 100 110 125 140 160 180 200 220 240 280
Stud/rebar diameter 8 0,25 0,44 0,63 0,81 1,00
10 0,30 0,48 0,65 0,83 1,00
12
0,30 0,44 0,58 0,72 0,86 1,00
56
16
20
24
0,40 0,53 0,67 0,35 0,80 0,44 1,00 0,58 0,35 0,72 0,46 0,91 0,62 1,00 0,77 0,92 1,00
30
0,30 0,35 0,46 0,57 0,68 0,78 1,00
(mm) 40 50 60 70 80 90 100 120 150 160 175 200 225 240 250 275 280 300 320 350 400 440 460 500 560
Stud/rebar diameter 8 0,64 0,67 0,70 0,73 0,76 0,79 0,82 0,87 0,96 1,00
10 0,63 0,65 0,67 0,69 0,72 0,74 0,79 0,86 0,88 0,92 1,00
12
0,63 0,64 0,66 0,68 0,70 0,74 0,80 0,82 0,85 0,90 0,95 1,00
16
0,63 0,64 0,65 0,68 0,73 0,74 0,76 0,80 0,84 0,86 0,87 0,91 0,92 0,95 1,00
20
0,63 0,65 0,68 0,70 0,71 0,74 0,77 0,79 0,80 0,83 0,84 0,86 0,88 0,92 1,00
24
0,63 0,65 0,66 0,67 0,69 0,72 0,73 0,74 0,76 0,77 0,79 0,81 0,83 0,88 0,92 1,00
30
0,63 0,63 0,64 0,66 0,68 0,69 0,70 0,72 0,73 0,74 0,76 0,78 0,82 0,85 0,87 0,90 1,00
chemical anchors
chemical anchors
Vorpa VIN Styrene free vinylester eco chemical anchor derived from epoxy acrylate resin with European Technical Assesment for non cracked concrete, post installed rebars and masonry technical data
concrete
natural stone
solid brick
perforated brick
Characteristic and Design Load resistances REBAR based on characteristic bond strengths for hef 4d (minimum embedment) to 20d
Non cracked concrete Characteristic Resistance (kN) Ø mm
8
10
12
14
16
18
20
22
25
28
32
Tension (Nrk)
Shear (Vrk)
16,59 22,12 44,23 20,73 31,10 69,12 29,03 45,62 99,53 35,19 50,58 123,15 40,21 62,83 160,85 45,24 84,82 203,58 56,55 106,81 251,33 69,12 131,32 304,11 78,54 164,93 392,70 88,67 221,67 443,34 115,81 289,53 579,06
13,95
21,45
31,05
42,45
55,50
69,66
86,55
104,01
135,00
168,75
220,95
Cracked concrete
Design Resistance Recommended Load (kN) (kN) Tension (Nrd) 9,22 12,29 24,57 11,52 17,28 38,40 16,13 25,34 55,29 19,55 28,10 68,42 22,34 34,91 89,36 25,13 47,12 113,10 31,42 59,34 139,63 38,40 72,95 168,95 43,63 91,63 218,17 49,26 123,15 246,30 64,34 160,85 321,70
Shear (Vrd)
9,30
14,30
20,70
28,30
37,00
46,44
57,70
69,34
90,00
112,50
147,30
Tension (Nrec) 6,58 8,78 17,55 8,23 12,34 27,43 11,52 18,10 39,49 13,96 20,07 48,87 15,96 24,93 63,83 17,95 33,66 80,78 22,44 42,39 99,73 27,43 52,11 120,68 31,17 65,45 155,83 35,19 87,96 175,93 45,96 114,89 229,79
Characteristic Resistance (kN)
Shear (Vrec)
Tension (Nrk)
Shear (Vrk)
Design Resistance Recommended Load (kN) (kN) Tension (Nrd)
Shear (Vrd)
Tension (Nrec)
Shear (Vrec)
6,64
Not applicable
Not applicable
Not applicable
10,21
Not applicable
Not applicable
Not applicable
14,79
Not applicable
Not applicable
Not applicable
20,21
Not applicable
Not applicable
Not applicable
26,43
Not applicable
Not applicable
Not applicable
33,17
Not applicable
Not applicable
Not applicable
41,21
Not applicable
Not applicable
Not applicable
49,53
Not applicable
Not applicable
Not applicable
64,29
Not applicable
Not applicable
Not applicable
80,36
Not applicable
Not applicable
Not applicable
105,21
Not applicable
Not applicable
Not applicable
Nominal Embedment
(mm) 60 80 160 60 90 200 70 110 240 80 115 280 80 125 320 80 150 360 90 170 400 100 190 440 100 210 500 112 280 560 128 320 640
All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C
Bond Strength Factors Influence of concrete strength on combined pull out and concrete cone resistance (rebar) Concrete Strength N/mm2 (Mpa) non cracked fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.97
1.00
1.03
1.06
1.09
1.12
1.16
1.20
Influence of environmental conditions in non cracked concrete (rebar)
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
Ø8
Ø 10
Ø 12
Ø 14
Ø 16
Ø 18
Ø 20
Ø 22
Ø 25
Ø 28
Ø 32
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
57
chemical anchors
chemical anchors
Vorpa PSF Styrene free polyester chemical anchor with European Technical Assesment for non cracked concrete and masonry products group
concrete
Approved for • non cracked concrete M8-M16 • ETAG 029 Hollow Wall and masonry installation M10 Tested for • lamellar wood GL24 Also suitable for • natural stone • solid brick • perforated brick
natural stone
solid brick
perforated brick
To fix • non-structural fixings • light metal structures • light structural works • solar panel fixing • scaffolding links • floor reinforcement • construction joints • railings
rticale Sta in ve opic Thixotr
PSF 300
CALCULATION SOFTWARE
PSF 400 PSF 165
Tested for LEED compliancy ETAG 001-05 for non cracked concrete M8-M16 threaded bar
ETAG 029 for masonry and hollow walls - Cat.c,w/d M10 Steel elements according to Table 2 Annex 5 ETA-11/0511
Test report nr. 276986 14/12/2010 on wood substrates
product code Code
Description
1129 PSF 165 1124 PSF 300 1002P PSF 400
Content ml
Gun to be used
Shelf life
165 300 410
silicone type silicone type coaxial
12 months 12 months 12 months
Store upright
Examples of applications
58
Styrene Free
wood
chemical anchors
chemical anchors
Vorpa PSF Styrene free polyester chemical anchor with European Technical Assesment for non cracked concrete and masonry product information Characteristics • polyester styrene free chemical anchors • European Technical Assessment for use in masonry and non-cracked concrete • suitable for medium loads for non-critical applications • fast working times for early loading in time sensitive applications • no styrene allows for use indoors and enclosed spaces • use in damp & wet environment and flooded fixing holes • extremely versatile in masonry, hollow, aerated concrete • crack and gap filling repairs in concrete vertical or horizontal 10:1 resin available in variety of cartridges types • cartridge can be used up to the end of the validity date by replacing the static mixer or releasing cartridge with the sealing cap • for applications on hollow materials use the appropriate perforated sleeves
concrete
natural stone
solid brick
perforated brick
wood
Approval/certifications/testing • 15/0030 - non-Cracked Concrete. Includes flooded holes • 11/0511 - ETA ETAG 029 hollow Wall / mansory Installations • ITB Approval (Poland) 0978/W • LEED tested 2009 EQ. c4, 1 SCAQMD rule 1168 (2005) Suggestion for use • performance based on clean holes. • HAMMER DRILLED – blown and then brushed with a stiff metal brush and blown again
installation sequence On solid brick
Clean the hole before the installation
On hollow brick
technical data Physical Properties Compressive Strength Flexural Strength Flexural Modulus Tensile Strength E Modulus VOC Content
N/mm2 (MPa) 43,5 15,9 2803,0 9,3 4874,5 A+
Test Method
EN ISO 604 / ASTM 695 EN ISO 178 / ASTM 790 EN ISO 178 / ASTM 790 EN ISO 527 / ASTM 638 EN ISO 527 / ASTM 638 -
59
chemical anchors
chemical anchors
Vorpa PSF Styrene free polyester chemical anchor with European Technical Assesment for non cracked concrete and masonry technical data Minimum Curing Time Concrete Temperature
solid brick
perforated brick
wood
Temperature Ranges
Gel-working Minimum curing Minimum curing time in Time time in dry concrete wet concrete
x2 x2 x2 x2 x2 x2
240 min 180 min 90 min 60 min 30 min 20 min
50 min 40 min 20 min 9 min 5 min 3 min
-10°C * -5°C * 5°C 15°C 25°C 35°C
natural stone
concrete
Range
Concrete Service Temperature
Maximum Long Term Concrete Temperature
Maximum Short Term Concrete Temperature
Range I Range II
-40°C to +40°C -40°C to +80°C
+24°C +50°C
+40°C +80°C
Service temperature range: Range of ambient temperatures after installation and during the lifetime of the anchor. Short term temperature: Temperature within the service temperature range which vary over short intervals, e.g. day/ night cycles and freeze/than cycles. Long term temperature: Temperature, within the service temperature range, which will be approximately constant over significant periods of time.
*resin temperature must be at least 20°C Full cure 24 hours. All specifications based on supplied mixer Store at temperatures between +5 and +25 degrees, away from direct heat, rain and moisture
Typical characteristic and design resistance performance with 5.8 grade studding and associated installation data Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
30
Tension (Nrk)
Shear (Vrk)
15,71 19,00 19,00 17,53 26,30 30,20 23,09 36,29 43,80 33,38 52,15 81,60 43,60 82,35 127,40 49,01 102,92 183,60 61,07 142,50 292,00
9,00
15,00
21,00
39,00
61,00
88,00
142,50
Design Resistance Recommended Load Characteristic distances (kN) (kN) (mm)
Min Edge and Spacing
Tension (Nrd)
(mm) (Cmin Smin)
7,27 9,70 12,70 8,12 12,17 20,10 10,69 16,80 29,20 15,45 24,14 54,40 20,18 38,13 84,90 22,69 47,65 122,40 28,27 65,97 194,50
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
114,00
Tension (Nrec) 5,20 6,93 9,07 5,80 8,70 14,36 7,64 12,00 20,86 11,04 17,25 38,86 14,42 27,23 60,64 16,21 34,03 87,43 20,20 47,12 138,93
Shear (Vrec)
Edge Spacing Edge (Ccr,N) (Scr,N) (Ccr,V)
5,14
80
160
80
40
8,57
100
200
90
50
12,00
120
240
110
60
22,29
160
320
125
80
34,86
200
400
180
100
50,29
225
450
220
120
81,43
260
520
280
150
Nominal Hole Hole Max Embedment diameterdiameter Torque concrete fixture (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600
(mm)
(mm)
(Nm)
10
9
10
12
12
20
14
14
40
18
18
80
24
22
120
28
26
160
35
32
200
All data is based on correct installation - see instructions. No influence of edge and spacing Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Steel failure
Design resistance of resin with various stud strenghts and rebar 5.8 grade steel studding Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
hef failure
embedment depth 60 7.3 8.1
60
70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
90
100 12.1 13.5 15.5 19.3 22.4 22.6
110 12.7 14.9 17.0 21.2 24.7 24.9 26.1
100
110
120 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 20.1 24.7 30.9 35.9 36.2 38.0 37.7 160
200 29.2 38.6 44.9 45.2 47.5 47.1 200
60
240
46.3 53.8 54.3 57.0 58.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
54.4 71.8 72.4 76.0 75.4 320
400
480
540
600
660
84.9 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660
720
720
Fd,s design load
(mm)
(kN)
105 148 189 282 379 541 670 825
12.7 20.1 29.2 54.4 84.9 122.4 159.1 194.5
chemical anchors
chemical anchors
Vorpa PSF Styrene free polyester chemical anchor with European Technical Assesment for non cracked concrete and masonry technical data
concrete
natural stone
solid brick
Design resistance of resin with various stud strenghts and rebar
perforated brick
wood
Steel failure
8.8 grade steel studding Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
hef 60 7.3 8.1
60
depth mm
failure
embedment depth 70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
90
100 12.1 13.5 15.5 19.3 22.4 22.6
110 13.3 14.9 17.0 21.2 24.7 24.9 26.1
100
110
120 14.5 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 15.8 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 17.0 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 19.5 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160
200 27.1 30.9 38.6 44.9 45.2 47.5 47.1 200
240 37.1 46.3 53.8 54.3 57.0 58.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
61.8 71.8 72.4 76.0 75.4 320
400
480
540
600
660
89.7 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660
720
Fd,s design load
(mm)
(kN)
161 228 291 434 582 832 1031 1270
19.5 30.9 45.0 83.7 130.7 188.3 244.8 299.2
720
10.9 grade steel studding Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
hef 60 7.3 8.1
60
depth mm
failure
embedment depth 70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
90
100 12.1 13.5 15.5 19.3 22.4 22.6
110 13.3 14.9 17.0 21.2 24.7 24.9 26.1
100
110
120 14.5 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 15.8 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 17.0 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 19.4 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160
200 27.1 30.9 38.6 44.9 45.2 47.5 47.1 200
240 37.1 46.3 53.8 54.3 57.0 58.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
61.8 71.8 72.4 76.0 75.4 320
400
480
540
600
660
89.7 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660
720
Fd,s design load
(mm)
(kN)
224 318 405 604 811 1159 1435 1768
27.2 43.1 62.6 116.6 182.0 262.2 341.0 416.7
720
A-70 stainless steel studding Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
hef 60 7.3 8.1
60
depth mm
failure
embedment depth 70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
90
100 12.1 13.5 15.5 19.3 22.4 22.6
100
110 13.3 14.9 17.0 21.2 24.7 24.9 26.1 110
120 13.7 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160
200 30.9 38.6 44.9 45.2 47.5 47.1 200
240 31.6 46.3 53.8 54.3 57.0 56.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
58.8 71.8 72.4 76.0 75.4 320
400
480
540
89.7 90.5 108.6 80.2 94.3 98.1 400 480 540
600
600
660
660
720
1 1 720
Fd,s design load
(mm)
(kN)
113 160 204 304 409 584 338 416
13.7 21.7 31.6 58.8 91.7 132.1 80.2 98.1
*1 = tensile strenght 500N/mm2
High bond reinforcing bars Fyk = 500 N/mm2 Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 25 28 32
10 12 15 20 25 30 35 40
depth mm
hef failure
embedment depth 60 6.3 7.6
60
70 7.4 8.8 9.4
70
80 8.4 10.1 10.8 13.3 14.1
90 9.5 11.4 12.1 14.9 15.8
100 10.6 12.6 13.5 16.6 17.6 18.5
110 11.6 13.9 14.8 18.2 19.4 20.3 21.5
120 12.7 15.2 16.2 19.9 21.1 22.2 23.4
80
90
100
110
120
130 13.7 16.4 17.5 21.6 22.9 24.0 25.4 26.1 130
140 14.8 17.7 18.9 23.2 24.6 25.8 27.3 28.2 140
160 16.9 20.2 21.6 26.5 28.2 29.5 31.2 32.2 160
200 25.3 27.0 33.2 35.2 36.9 39.1 40.2 200
61
240 32.4 39.8 42.2 44.3 46.9 48.3 240
280
46.5 49.3 51.7 54.7 56.3 280
320
53.1 56.3 59.1 62.5 64.3 320
400
500
560
640
720
70.4 73.8 92.3 78.1 97.7 109.4 80.4 100.5 112.6 128.7 400 500 560 640 720
800
800
Fd,s design load
(mm)
(kN)
207 270 364 527 776 1065 1371 1739
21.9 34.1 49.2 87.4 136.6 196.5 267.8 349.7
chemical anchors
chemical anchors
Vorpa PSF Styrene free polyester chemical anchor with European Technical Assesment for non cracked concrete and masonry technical data
natural stone
concrete
solid brick
perforated brick
wood
Characteristic and Design Load resistances based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non cracked concrete Characteristic Resistance (kN) Ø mm
Tension (Nrk)
8
10
12
16
20
24
30
15,71 20,95 41,90 17,53 26,30 58,43 23,09 36,29 79,17 33,38 52,15 133,51 43,60 82,35 193,77 49,01 102,92 235,24 61,07 142,50 305,36
Cracked concrete
Design Resistance Recommended Load (kN) (kN)
Shear (Vrk)
Tension (Nrd)
Shear (Vrd)
7,27 9,70 19,40 8,12 12,17 27,05 10,69 16,80 36,65 15,45 24,14 61,81 20,18 38,13 89,71 22,69 47,65 108,91 28,27 65,97 141,37
9,00
15,00
21,00
39,00
61,00
88,00
142,50
7,20
12,00
16,80
31,20
48,80
70,40
114,00
Tension (Nrec) 5,20 6,93 13,86 5,80 8,70 19,32 7,64 12,00 26,18 11,04 17,25 44,15 14,42 27,23 64,08 16,21 34,03 77,79 20,20 47,12 100,98
Characteristic Resistance (kN)
Shear (Vrec)
Tension (Nrk)
Shear (Vrk)
Design Resistance Recommended Load (kN) (kN) Tension (Nrd)
Shear (Vrd)
Tension (Nrec)
Nominal Embedment
Shear (Vrec)
5,14
Not applicable
Not applicable
Not applicable
8,57
Not applicable
Not applicable
Not applicable
12,00
Not applicable
Not applicable
Not applicable
22,29
Not applicable
Not applicable
Not applicable
34,86
Not applicable
Not applicable
Not applicable
50,29
Not applicable
Not applicable
Not applicable
81,43
Not applicable
Not applicable
Not applicable
(mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600
All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C
Bond Strength Factors Effect of anchor spacing - Tension Spacing (mm) 40 50 60 70 80 90 100 120 150 160 175 200 225 240 250 275 280 300 320 350 400 425 450 480 520
Effect of edge distance - Tension
Stud/rebar diameter 8 0,64 0,67 0,70 0,73 0,76 0,79 0,82 0,87 0,96 1,00
10 0,63 0,65 0,67 0,69 0,72 0,74 0,79 0,86 0,88 0,92 1,00
12
0,63 0,64 0,66 0,68 0,70 0,74 0,80 0,82 0,85 0,90 0,95 1,00
16
0,63 0,64 0,65 0,68 0,73 0,74 0,76 0,80 0,84 0,86 0,87 0,91 0,92 0,95 1,00
20
0,63 0,65 0,68 0,70 0,71 0,74 0,77 0,79 0,80 0,83 0,84 0,86 0,88 0,92 1,00
24
0,63 0,65 0,66 0,68 0,71 0,74 0,76 0,77 0,80 0,80 0,82 0,85 0,88 0,94 0,97 1,00
30
0,63 0,64 0,65 0,68 0,70 0,72 0,73 0,75 0,76 0,78 0,80 0,83 0,88 0,90 0,93 0,96 1,00
Edge distance (mm) 40 50 60 70 80 90 100 110 120 140 160 180 200 225 250 260
Effect of edge distance - Shear
Stud/rebar diameter 8 0,64 0,73 0,82 0,90 1,00
10 0,63 0,70 0,77 0,84 0,91 1,00
12
0,63 0,68 0,74 0,80 0,86 0,92 1,00
62
16
0,63 0,67 0,71 0,76 0,80 0,89 1,00
20
0,63 0,66 0,70 0,77 0,84 0,91 1,00
24
0,64 0,68 0,76 0,84 0,92 1,00
30
0,63 0,66 0,72 0,78 0,86 0,94 1,00
Edge distance (mm) 40 50 60 70 80 90 100 110 125 140 160 180 200 225 250 280
Stud/rebar diameter 8 0,25 0,44 0,63 0,81 1,00
10 0,30 0,48 0,65 0,83 1,00
12
0,30 0,44 0,58 0,72 0,86 1,00
16
20
24
0,40 0,53 0,67 0,35 0,80 0,44 1,00 0,58 0,35 0,72 0,45 0,91 0,58 1,00 0,71 0,84 1,00
30
0,30 0,36 0,47 0,59 0,74 0,88 1,00
chemical anchors
chemical anchors
Vorpa PSF Styrene free polyester chemical anchor with European Technical Assesment for non cracked concrete and masonry technical data
concrete
natural stone
solid brick
perforated brick
wood
Characteristic and Design Load resistances REBAR based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non cracked concrete Characteristic Resistance (kN) Ø mm
8
10
12
16
20
25
28
32
Tension (Nrk) 13,30 17,73 35,47 15,91 23,86 53,03 19,84 31,18 68,04 27,87 43,54 111,47 32,23 60,88 143,26 38,80 81,48 193,99 46,30 115,76 231,52 54,05 135,11 270,23
Shear (Vrk)
13.95
21,45
31,05
55,50
86,55
135,00
168,75
220,95
Cracked concrete
Design Resistance Recommended Load (kN) (kN) Tension (Nrd) 6,33 8,44 16,89 7,58 11,36 25,25 9,45 14,85 32,40 13,27 20,73 53,08 15,35 28,99 68,22 18,48 38,80 92,38 22,05 55,12 110,25 25,74 64,34 128,68
Shear (Vrd)
Tension (Nrec) 4,52 6,03 12,06 5,41 8,12 18,04 6,75 10,61 23,14 9,48 14,81 37,91 10,96 20,71 48,73 13,20 27,71 65,98 15,75 39,37 78,75 18,38 45,96 91,91
9,30
14,30
20,70
37,00
57,30
90,00
112,50
147,30
Characteristic Resistance (kN)
Shear (Vrec)
Tension (Nrk)
Shear (Vrk)
Design Resistance Recommended Load (kN) (kN) Tension (Nrd)
Shear (Vrd)
Tension (Nrec)
Shear (Vrec)
6,64
Not applicable
Not applicable
Not applicable
10,21
Not applicable
Not applicable
Not applicable
14,79
Not applicable
Not applicable
Not applicable
26,43
Not applicable
Not applicable
Not applicable
41,21
Not applicable
Not applicable
Not applicable
64,29
Not applicable
Not applicable
Not applicable
80,36
Not applicable
Not applicable
Not applicable
105,22
Not applicable
Not applicable
Not applicable
Nominal Embedment
(mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 500 112 280 560 128 320 640
All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C
Bond Strength Factors Influence of concrete strength on combined pull out and concrete cone resistance (threaded bar) Concrete Strength N/mm2 (Mpa) non fessurato fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.97
1.00
1.02
1.04
1.07
1.10
1.12
1.15
Influence of environmental conditions in non cracked concrete (threaded bar)
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
M8
M10
M12
M16
M20
M24
M30
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.90
0.88
0.87
0.86
0.85
0.84
0.82
Influence of concrete strength on combined pull out and concrete cone resistance (rebar) Concrete Strength N/mm2 (Mpa) non cracked fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.97
1.00
1.02
1.04
1.07
1.10
1.12
1.15
Influence of environmental conditions in non cracked concrete (rebar)
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
Ø8
Ø 10
Ø 12
Ø 16
Ø 20
Ø 25
Ø 28
Ø 32
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.90
0.90
0.88
0.88
0.86
0.86
0.84
0.84
63
chemical anchors
chemical anchors
Vorpa PSF Styrene free polyester chemical anchor with European Technical Assesment for non cracked concrete and masonry technical data
concrete
natural stone
solid brick
perforated brick
wood
TECHNICAL DATA FOR APPLICATION ON WOOD Recommended load for applications on glued lamellar wood in conformity with UNI EN 1194 Characteristics of glued lamellar wood UNI EN 1194 Strenght Flexion Parallel Tensile Strenght Perpendicular Tensile Strenght Parallel Compressive Strenght Perpendicular Compressive Strenght Shear Strenght Average Modulus of Elasticity Average Modulus of Shear Volume
N/mm2 fm,k ft,0,k ft,90,k fc,0,k fc,90,k fv,k Eo,mean G mean Pk
Technical data and recommended loads on glued lamellar wood type GL24h Stud size Hole diameter Hole depth (mm) (mm)
GL24 24 16,5 0,4 24 2,7 2,7 11.600 720 380
M8 M10 M12
Test Report nr. 276986 - 14/12/2010
Examples of installation
Examples of applications
64
10 12 14
80 90 100
Permissible loads kN 3,3 4,5 8,1
chemical anchors
chemical anchors
Vorpa PTR TROPICAL Styrene free polyester chemical anchor for application in high ambient temperatures
concrete
natural stone
solid brick
perforated brick
products group Suitable for • concrete • natural stone • solid brick • hollow brick
To fix • non-structural fixings • light metal works • light structural works • solar panel fixing • scaffolding links • floor reinforcement • construction joints • railings
TROPICAL fino a up to
+45°C
Tested for LEED compliancy
PTR TROPICAL 400
Styrene Free
product information Approval/certifications/testing • ITB Approval (Poland) 0974/W • LEED tested 2009 EQ. c4, 1 SCAQMD rule 1168 (2005) • VOC A+ Rating (Volatile Organic Content)
Characteristics • polyester chemical anchors injection system for application in concrete, masonry and hollow bricks. • used widely for installations in high temperature and humidity situations • suitable for medium loads for non-critical applications • longer working times in high temperature applications • use in extremely warm environments and fixing holes • extremely versatile in masonry, hollow, aerated concrete • crack and gap filling repairs in concrete vertical or horizontal • 10:1 resin available in variety of cartridges types
Suggestion for use • performance based on clean holes. • HAMMER DRILLED – blown and then brushed with a stiff metal brush and blown again
product code Code
Description
1159
PTR TROPICAL 400
Content ml
Gun to be used
Shelf life
410
coaxial
12 months
Store upright
Examples of applications
65
chemical anchors
chemical anchors
Vorpa PTR TROPICAL Styrene free polyester chemical anchor for application in high ambient temperatures
concrete
natural stone
solid brick
perforated brick
installation sequence Clean the hole before the installation
On solid brick
On hollow brick
technical data Physical Properties Compressive Strength Flexural Strength Flexural Modulus Tensile Strength E Modulus VOC Content
N/mm2 (MPa)
Test Method
43,5 15,9 2803,0 9,3 4874,5 A+
EN ISO 604 / ASTM 695 EN ISO 178 / ASTM 790 EN ISO 178 / ASTM 790 EN ISO 527 / ASTM 638 EN ISO 527 / ASTM 638 -
Temperature Ranges
Minimum Curing Time Concrete Temperature
Gel-working Time
5°C 15°C 25°C 35°C 45°C
45 min 18 min 10 min 5 min 2 min
Minimum curing Minimum curing time time in dry concrete in wet concrete
120 min 75 min 45 min 30 min 15 min
x2 x2 x2 x2 x2
Range
Concrete Service Temperature
Maximum Long Term Concrete Temperature
Maximum Short Term Concrete Temperature
Range I Range II
-40°C to +40°C -40°C to +80°C
+24°C +50°C
+40°C +80°C
Service temperature range: Range of ambient temperatures after installation and during the lifetime of the anchor. Short term temperature: Temperature within the service temperature range which vary over short intervals, e.g. day/ night cycles and freeze/than cycles. Long term temperature: Temperature, within the service temperature range, which will be approximately constant over significant periods of time.
Full cure 24 hours. All specifications based on supplied mixer Store at temperatures between +5 and +25 degrees, away from direct heat, rain and moisture
66
chemical anchors
chemical anchors
Vorpa PTR TROPICAL Styrene free polyester chemical anchor for application in high ambient temperatures
concrete
natural stone
solid brick
perforated brick
technical data Typical characteristic and design resistance performance with 5.8 grade studding and associated installation data
Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
30
Tension (Nrk)
Shear (Vrk)
15,71 19,00 19,00 17,53 26,30 30,20 23,09 36,29 43,80 33,38 52,15 81,60 43,60 82,35 127,40 49,01 102,92 183,60 61,07 142,50 292,00
9,00
15,00
21,00
39,00
61,00
88,00
142,50
Design Resistance Recommended Load Characteristic distances (kN) (kN) (mm)
Min Edge and Spacing
Tension (Nrd)
(mm) (Cmin Smin)
7,27 9,70 12,70 8,12 12,17 20,10 10,69 16,80 29,20 15,45 24,14 54,40 20,18 38,13 84,90 22,69 47,65 122,40 28,27 65,97 194,50
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
114,00
Tension (Nrec) 5,20 6,93 9,07 5,80 8,70 14,36 7,64 12,00 20,86 11,04 17,25 38,86 14,42 27,23 60,64 16,21 34,03 87,43 20,20 47,12 138,93
Shear (Vrec)
Edge Spacing Edge (Ccr,N) (Scr,N) (Ccr,V)
5,14
80
160
80
40
8,57
100
200
90
50
12,00
120
240
110
60
22,29
160
320
125
80
34,86
200
400
180
100
50,29
225
450
220
120
81,43
260
520
280
150
Nominal Hole Hole Max Embedment diameterdiameter Torque concrete fixture (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600
(mm)
(mm)
(Nm)
10
9
10
12
12
20
14
14
40
18
18
80
24
22
120
28
26
160
35
32
200
All data is based on correct installation - see instructions No influence of edge and spacing Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d
Steel failure
Design resistance of resin with various stud strenghts and rebar
Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
5.8 grade steel studding
hef failure
embedment depth 60 7.3 8.1
60
70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
90
100 12.1 13.5 15.5 19.3 22.4 22.6
110 12.7 14.9 17.0 21.2 24.7 24.9 26.1
100
110
120 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 20.1 24.7 30.9 35.9 36.2 38.0 37.7 160
200 29.2 38.6 44.9 45.2 47.5 47.1 200
240
46.3 53.8 54.3 57.0 58.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
54.4 71.8 72.4 76.0 75.4 320
400
480
540
600
660
84.9 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660
720
60
70
80
90
(kN)
105 148 189 282 379 541 670 825
12.7 20.1 29.2 54.4 84.9 122.4 159.1 194.5
hef failure
embedment depth 70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
(mm)
720
8.8 grade steel studding
60 7.3 8.1
100 12.1 13.5 15.5 19.3 22.4 22.6
110 13.3 14.9 17.0 21.2 24.7 24.9 26.1
100
110
120 14.5 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 15.8 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 17.0 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 19.5 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160
200 27.1 30.9 38.6 44.9 45.2 47.5 47.1 200
67
240 37.1 46.3 53.8 54.3 57.0 58.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
61.8 71.8 72.4 76.0 75.4 320
400
480
540
600
660
89.7 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660
Fd,s design load
720
720
Fd,s design load
(mm)
(kN)
161 228 291 434 582 832 1031 1270
19.5 30.9 45.0 83.7 130.7 188.3 244.8 299.2
chemical anchors
chemical anchors
Vorpa PTR TROPICAL Styrene free polyester chemical anchor for application in high ambient temperatures
natural stone
concrete
solid brick
perforated brick
technical data Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
60 7.3 8.1
Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 25 28 32
10 12 15 20 25 30 35 40
70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
90
100 12.1 13.5 15.5 19.3 22.4 22.6
110 13.3 14.9 17.0 21.2 24.7 24.9 26.1
100
110
130 15.8 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 17.0 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 19.4 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160
200
240
27.1 30.9 38.6 44.9 45.2 47.5 47.1 200
37.1 46.3 53.8 54.3 57.0 58.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
61.8 71.8 72.4 76.0 75.4 320
400
480
540
600
660
720
89.7 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660
70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
90
100 12.1 13.5 15.5 19.3 22.4 22.6
100
60
70
110 13.3 14.9 17.0 21.2 24.7 24.9 26.1 110
120 13.7 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
80 8.4 10.1 10.8 13.3 14.1
90 9.5 11.4 12.1 14.9 15.8
100 10.6 12.6 13.5 16.6 17.6 18.5
110 11.6 13.9 14.8 18.2 19.4 20.3 21.5
120 12.7 15.2 16.2 19.9 21.1 22.2 23.4
80
90
100
110
120
Stud/rebar diameter 8 10 12 16 0,64 0,67 0,63 0,70 0,65 0,63 0,73 0,67 0,64 0,76 0,69 0,66 0,63 0,79 0,72 0,68 0,64 0,82 0,74 0,70 0,65 0,87 0,79 0,74 0,68 0,96 0,86 0,80 0,73 1,00 0,88 0,82 0,74 0,92 0,85 0,76 1,00 0,90 0,80 0,95 0,84 1,00 0,86 0,87 0,91 0,92 0,95 1,00
130 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160
200
240
30.9 38.6 44.9 45.2 47.5 47.1 200
31.6 46.3 53.8 54.3 57.0 56.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
58.8 71.8 72.4 76.0 75.4 320
400
480
540
89.7 90.5 108.6 80.2 94.3 98.1 400 480 540
600
600
660
720
1 1 720
660
130 13.7 16.4 17.5 21.6 22.9 24.0 25.4 26.1 130
0,63 0,65 0,68 0,70 0,71 0,74 0,77 0,79 0,80 0,83 0,84 0,86 0,88 0,92 1,00
24
0,63 0,65 0,66 0,68 0,71 0,74 0,76 0,77 0,80 0,80 0,82 0,85 0,88 0,94 0,97 1,00
30
0,63 0,64 0,65 0,68 0,70 0,72 0,73 0,75 0,76 0,78 0,80 0,83 0,88 0,90 0,93 0,96 1,00
Edge distance (mm) 40 50 60 70 80 90 100 110 120 140 160 180 200 225 250 260
(kN)
113 160 204 304 409 584 338 416
13.7 21.7 31.6 58.8 91.7 132.1 80.2 98.1
hef 140 14.8 17.7 18.9 23.2 24.6 25.8 27.3 28.2 140
160 16.9 20.2 21.6 26.5 28.2 29.5 31.2 32.2 160
200
240
25.3 27.0 33.2 35.2 36.9 39.1 40.2 200
32.4 39.8 42.2 44.3 46.9 48.3 240
280
46.5 49.3 51.7 54.7 56.3 280
320
53.1 56.3 59.1 62.5 64.3 320
400
10 0,63 0,70 0,77 0,84 0,91 1,00
12
0,63 0,68 0,74 0,80 0,86 0,92 1,00
68
16
0,63 0,67 0,71 0,76 0,80 0,89 1,00
560
640
720
800
70.4 73.8 92.3 78.1 97.7 109.4 80.4 100.5 112.6 128.7 400 500 560 640 720
Fd,s design load
(mm)
(kN)
207 270 364 527 776 1065 1371 1739
21.9 34.1 49.2 87.4 136.6 196.5 267.8 349.7
800
Effect of edge distance - Shear
Stud/rebar diameter 8 0,64 0,73 0,82 0,90 1,00
500
Fd,s design load
(mm)
failure
Effect of edge distance - Tension
20
27.2 43.1 62.6 116.6 182.0 262.2 341.0 416.7
hef
embedment depth 70 7.4 8.8 9.4
(kN)
224 318 405 604 811 1159 1435 1768
failure
High bond reinforcing bars Fyk = 500 N/mm2
60 6.3 7.6
(mm)
720
embedment depth 60 7.3 8.1
Fd,s design load
*1 = tensile strenght 500N/mm2
Effect of anchor spacing - Tension Spacing (mm) 40 50 60 70 80 90 100 120 150 160 175 200 225 240 250 275 280 300 320 350 400 425 450 480 520
120 14.5 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
A-70 stainless steel studding
60
depth mm
hef failure
embedment depth
60
depth mm
depth mm
10.9 grade steel studding
20
0,63 0,66 0,70 0,77 0,84 0,91 1,00
24
0,64 0,68 0,76 0,84 0,92 1,00
30
0,63 0,66 0,72 0,78 0,86 0,94 1,00
Edge distance (mm) 40 50 60 70 80 90 100 110 125 140 160 180 200 225 250 280
Stud/rebar diameter 8 0,25 0,44 0,63 0,81 1,00
10 0,30 0,48 0,65 0,83 1,00
12
0,30 0,44 0,58 0,72 0,86 1,00
16
20
24
0,40 0,53 0,67 0,35 0,80 0,44 1,00 0,58 0,35 0,72 0,45 0,91 0,58 1,00 0,71 0,84 1,00
30
0,30 0,36 0,47 0,59 0,74 0,88 1,00
chemical anchors
chemical anchors
Vorpa PTR TROPICAL Styrene free polyester chemical anchor for application in high ambient temperatures
concrete
natural stone
solid brick
perforated brick
technical data Characteristic and Design Load resistances based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non cracked concrete Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
30
Tension (Nrk) 15,71 20,95 41,90 17,53 26,30 58,43 23,09 36,29 79,17 33,38 52,15 133,51 43,60 82,35 193,77 49,01 102,92 235,24 61,07 142,50 305,36
Shear (Vrk)
9,00
15,00
21,00
39,00
61,00
88,00
142,50
Cracked concrete
Design Resistance Recommended Load (kN) (kN) Tension (Nrd) 7,27 9,70 19,40 8,12 12,17 27,05 10,69 16,80 36,65 15,45 24,14 61,81 20,18 38,13 89,71 22,69 47,65 108,91 28,27 65,97 141,37
Shear (Vrd)
Tension (Nrec) 5,20 6,93 13,86 5,80 8,70 19,32 7,64 12,00 26,18 11,04 17,25 44,15 14,42 27,23 64,08 16,21 34,03 77,79 20,20 47,12 100,98
7,20
12,00
16,80
31,20
48,80
70,40
114,00
Characteristic Resistance (kN)
Shear (Vrec)
Tension (Nrk)
Shear (Vrk)
Design Resistance Recommended Load (kN) (kN) Tension (Nrd)
Shear (Vrd)
Tension (Nrec)
Shear (Vrec)
5,14
Not applicable
Not applicable
Not applicable
8,57
Not applicable
Not applicable
Not applicable
12,00
Not applicable
Not applicable
Not applicable
22,29
Not applicable
Not applicable
Not applicable
34,86
Not applicable
Not applicable
Not applicable
50,29
Not applicable
Not applicable
Not applicable
81,43
Not applicable
Not applicable
Not applicable
Nominal Embedment
(mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600
All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C
Bond Strength Factors Influence of concrete strength on combined pull out and concrete cone resistance (threaded bar) Concrete Strength N/mm2 (Mpa) non fessurato fc=
C15/20
C20/25
0.97
1.00
C25/30 1.02
C30/37
C35/45
C40/50
C45/55
C50/60
1.04
1.07
1.10
1.12
1.15
Influence of environmental conditions in non cracked concrete (threaded bar)
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
M8
M10
M12
M16
M20
M24
M30
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.90
0.88
0.87
0.86
0.85
0.84
0.82
69
chemical anchors
chemical anchors
Vorpa PTR TROPICAL Styrene free polyester chemical anchor for application in high ambient temperatures
concrete
natural stone
solid brick
perforated brick
technical data Characteristic and Design Load resistances REBAR based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non cracked concrete Characteristic Resistance (kN) Ø mm
8
10
12
16
20
25
28
32
Tension (Nrk) 13,30 17,73 35,47 15,91 23,86 53,03 19,84 31,18 68,04 27,87 43,54 111,47 32,23 60,88 143,26 38,80 81,48 193,99 46,30 115,76 231,52 54,05 135,11 270,23
Shear (Vrk)
13.95
21,45
31,05
55,50
86,55
135,00
168,75
220,95
Cracked concrete
Design Resistance Recommended Load (kN) (kN) Tension (Nrd) 6,33 8,44 16,89 7,58 11,36 25,25 9,45 14,85 32,40 13,27 20,73 53,08 15,35 28,99 68,22 18,48 38,80 92,38 22,05 55,12 110,25 25,74 64,34 128,68
Shear (Vrd)
9,30
14,30
20,70
37,00
57,30
90,00
112,50
147,30
Tension (Nrec) 4,52 6,03 12,06 5,41 8,12 18,04 6,75 10,61 23,14 9,48 14,81 37,91 10,96 20,71 48,73 13,20 27,71 65,98 15,75 39,37 78,75 18,38 45,96 91,91
Characteristic Resistance (kN)
Shear (Vrec)
Tension (Nrk)
Shear (Vrk)
Design Resistance Recommended Load (kN) (kN) Tension (Nrd)
Shear (Vrd)
Tension (Nrec)
Shear (Vrec)
6,64
Not applicable
Not applicable
Not applicable
10,21
Not applicable
Not applicable
Not applicable
14,79
Not applicable
Not applicable
Not applicable
26,43
Not applicable
Not applicable
Not applicable
41,21
Not applicable
Not applicable
Not applicable
64,29
Not applicable
Not applicable
Not applicable
80,36
Not applicable
Not applicable
Not applicable
105,22
Not applicable
Not applicable
Not applicable
Nominal Embedment
(mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 500 112 280 560 128 320 640
All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C
Bond Strength Factors Influence of concrete strength on combined pull out and concrete cone resistance (rebar) Concrete Strength N/mm2 (Mpa) non cracked fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.97
1.00
1.02
1.04
1.07
1.10
1.12
1.15
Influence of environmental conditions in non cracked concrete (rebar)
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
Ø8
Ø 10
Ø 12
Ø 16
Ø 20
Ø 25
Ø 28
Ø 32
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.90
0.90
0.88
0.88
0.86
0.86
0.84
0.84
Examples of applications
70
chemical anchors
chemical anchors
Vorpa PWI WINTER Styrene free polyester chemical anchor with European Technical Assesment for non cracked concrete for application in low ambient temperatures products group Approved for • non cracked concrete M8-M16 Also suitable for • natural stone • solid brick • perforated brick
concrete
natural stone
solid brick
perforated brick
To fix • medium duty metal structures • light structural works • solar panel fixing • construction joints • scaffolding links • railings
WINTER fino a up to
-20°C
PWI WINTER 400
Tested for LEED compliancy
ETAG 001-05 for non cracked concrete M8-M16 threaded bar
Styrene Free
product information Approval/certifications/testing • 15/0030 - non-Cracked Concrete. Includes flooded holes • ITB Approval (Poland) 0978/W • LEED tested 2009 EQ. c4, 1 SCAQMD rule 1168 (2005) • VOC A+ Rating (Volatile Organic Content)
Characteristics • polyester styrene free chemical anchors for application in low
ambient temperatures
• European Technical Assessment for use in non-cracked concrete • fast working times for early loading in time sensitive applications • no styrene allows for use indoors and enclosed spaces • use in damp & wet environment and flooded fixing holes • extremely versatile in masonry, hollow, aerated concrete • crack and gap filling repairs in concrete vertical or horizontal • cartridge can be used up to the end of the validity date by replacing the static mixer or releasing cartridge with the sealing cap • for applications on hollow materials use the appropriate perforated sleeves
Suggestion for use • performance based on clean holes. • HAMMER DRILLED – blown and then brushed with a stiff metal brush and blown again
product code Code
Description
1168
PWI WINTER 400
Content ml
Gun to be used
Shelf life
410
coaxial
12 months
Store upright
Examples of applications
Revision 03-2021
71
chemical anchors
chemical anchors
Vorpa PWI WINTER Styrene free polyester chemical anchor with European Technical Assesment for non cracked concrete for application in low ambient temperatures installation sequence
concrete
natural stone
solid brick
perforated brick
Clean the hole before the installation
On solid brick
On hollow brick
technical data Physical Properties Compressive Strength Flexural Strength Flexural Modulus Tensile Strength E Modulus VOC Content
N/mm2 (MPa)
Test Method
43,5 15,9 2803 9,3 4874,5 A+
EN ISO 604 / ASTM 695 EN ISO 178 / ASTM 790 EN ISO 178 / ASTM 790 EN ISO 527 / ASTM 638 EN ISO 527 / ASTM 638 -
Minimum Curing Time Concrete Temperature
Gel-working Time
-20°C* -10°C* 0°C 5°C 15°C 25°C
70 min 50 min 40 min 20 min 9 min 5 min
Temperature Ranges Minimum curing Minimum curing time in time in dry concrete wet concrete
360 min 240 min 180 min 90 min 60 min 30 min
x2 x2 x2 x2 x2 x2
Range
Concrete Service Temperature
Maximum Long Term Concrete Temperature
Maximum Short Term Concrete Temperature
Range I Range II
-40°C to +40°C -40°C to +80°C
+24°C +50°C
+40°C +80°C
Service temperature range: Range of ambient temperatures after installation and during the lifetime of the anchor. Short term temperature: Temperature within the service temperature range which vary over short intervals, e.g. day/ night cycles and freeze/than cycles. Long term temperature: Temperature, within the service temperature range, which will be approximately constant over significant periods of time.
*resin temperature must be at least 20°C Full cure 24 hours. All specifications based on supplied mixer Store at temperatures between +5 and +25 degrees, away from direct heat, rain and moisture
Revision 03-2021
72
chemical anchors
chemical anchors
Vorpa PWI WINTER Styrene free polyester chemical anchor with European Technical Assesment for non cracked concrete for application in low ambient temperatures technical data
natural stone
concrete
solid brick
perforated brick
Typical characteristic and design resistance performance with 5.8 grade studding and associated installation data Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
30
Tension (Nrk)
Shear (Vrk)
15,71 19,00 19,00 17,53 26,30 30,20 23,09 36,29 43,80 33,38 52,15 81,60 43,60 82,35 127,40 49,01 102,92 183,60 61,07 142,50 292,00
9,00
15,00
21,00
39,00
61,00
88,00
142,50
Design Resistance Recommended Load Characteristic distances (kN) (kN) (mm)
Min Edge and Spacing
Nominal Embedment
Tension (Nrd)
(mm) (Cmin Smin)
(mm)
7,27 9,70 12,70 8,12 12,17 20,10 10,69 16,80 29,20 15,45 24,14 54,40 20,18 38,13 84,90 22,69 47,65 122,40 28,27 65,97 194,50
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
114,00
Tension (Nrec) 5,20 6,93 9,07 5,80 8,70 14,36 7,64 12,00 20,86 11,04 17,25 38,86 14,42 27,23 60,64 16,21 34,03 87,43 20,20 47,12 138,93
Shear (Vrec)
Edge Spacing Edge (Ccr,N) (Scr,N) (Ccr,V)
5,14
80
160
80
40
8,57
100
200
90
50
12,00
120
240
110
60
22,29
160
320
125
80
34,86
200
400
180
100
50,29
225
450
220
120
81,43
260
520
280
150
Hole Max Hole diameter diameter Torque concrete fixture
60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600
(mm)
(mm)
(Nm)
10
9
10
12
12
20
14
14
40
18
18
80
24
22
120
28
26
160
35
32
200
All data is based on correct installation - see instructions No influence of edge and spacing Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d
Steel failure
Design resistance of resin with various stud strenghts and rebar High bond reinforcing bars Fyk = 500 N/mm2 Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 25 28 32
10 12 15 20 25 30 35 40
hef 60 6.3 7.6
60
depth mm
failure
embedment depth 70 7.4 8.8 9.4
70
80 8.4 10.1 10.8 13.3 14.1
90 9.5 11.4 12.1 14.9 15.8
100 10.6 12.6 13.5 16.6 17.6 18.5
110 11.6 13.9 14.8 18.2 19.4 20.3 21.5
120 12.7 15.2 16.2 19.9 21.1 22.2 23.4
80
90
100
110
120
130 13.7 16.4 17.5 21.6 22.9 24.0 25.4 26.1 130
140 14.8 17.7 18.9 23.2 24.6 25.8 27.3 28.2 140
160 16.9 20.2 21.6 26.5 28.2 29.5 31.2 32.2 160
200 25.3 27.0 33.2 35.2 36.9 39.1 40.2 200
240 32.4 39.8 42.2 44.3 46.9 48.3 240
280
46.5 49.3 51.7 54.7 56.3 280
320
53.1 56.3 59.1 62.5 64.3 320
400
500
560
640
720
70.4 73.8 92.3 78.1 97.7 109.4 80.4 100.5 112.6 128.7 400 500 560 640 720
800
Fd,s design load
(mm)
(kN)
207 270 364 527 776 1065 1371 1739
21.9 34.1 49.2 87.4 136.6 196.5 267.8 349.7
800
5.8 grade steel studding Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
hef failure
embedment depth 60 7.3 8.1
60
70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
90
100 12.1 13.5 15.5 19.3 22.4 22.6
110 12.7 14.9 17.0 21.2 24.7 24.9 26.1
100
110
120 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 20.1 24.7 30.9 35.9 36.2 38.0 37.7 160
200 29.2 38.6 44.9 45.2 47.5 47.1 200
Revision 03-2021
73
240
46.3 53.8 54.3 57.0 58.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
54.4 71.8 72.4 76.0 75.4 320
400
480
540
600
660
84.9 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660
720
720
Fd,s design load
(mm)
(kN)
105 148 189 282 379 541 670 825
12.7 20.1 29.2 54.4 84.9 122.4 159.1 194.5
chemical anchors
chemical anchors
Vorpa PWI WINTER Styrene free polyester chemical anchor with European Technical Assesment for non cracked concrete for application in low ambient temperatures technical data Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
hef failure
embedment depth 60 7.3 8.1
70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
90
100 12.1 13.5 15.5 19.3 22.4 22.6
110 13.3 14.9 17.0 21.2 24.7 24.9 26.1
100
110
120 14.5 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 15.8 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 17.0 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 19.5 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160
200
240
27.1 30.9 38.6 44.9 45.2 47.5 47.1 200
280
37.1 46.3 53.8 54.3 57.0 58.6 240
54.1 62.8 63.3 66.5 66.0 280
320
400
61.8 71.8 72.4 76.0 75.4 320
480
540
600
660
720
89.7 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660
70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
90
110 13.3 14.9 17.0 21.2 24.7 24.9 26.1
100
110
120 14.5 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 15.8 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 17.0 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 19.4 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160
200
240
27.1 30.9 38.6 44.9 45.2 47.5 47.1 200
280
37.1 46.3 53.8 54.3 57.0 58.6 240
54.1 62.8 63.3 66.5 66.0 280
320
400
61.8 71.8 72.4 76.0 75.4 320
480
540
600
660
720
89.7 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660
60
70
80
90
(kN)
224 318 405 604 811 1159 1435 1768
27.2 43.1 62.6 116.6 182.0 262.2 341.0 416.7
hef
100 12.1 13.5 15.5 19.3 22.4 22.6
100
110 13.3 14.9 17.0 21.2 24.7 24.9 26.1 110
120 13.7 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160
200
240
30.9 38.6 44.9 45.2 47.5 47.1 200
280
31.6 46.3 53.8 54.3 57.0 56.6 240
54.1 62.8 63.3 66.5 66.0 280
320
58.8 71.8 72.4 76.0 75.4 320
400
480
540
89.7 90.5 108.6 80.2 94.3 98.1 400 480 540
600
600
Fd,s design load
(mm)
failure
embedment depth 70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
19.5 30.9 45.0 83.7 130.7 188.3 244.8 299.2
720
A-70 stainless steel studding
60 7.3 8.1
(kN)
161 228 291 434 582 832 1031 1270
hef 100 12.1 13.5 15.5 19.3 22.4 22.6
Fd,s design load
(mm)
failure
embedment depth 60 7.3 8.1
perforated brick
720
10.9 grade steel studding
60
depth mm
solid brick
8.8 grade steel studding
60
depth mm
natural stone
concrete
660
720
1 1 720
660
Fd,s design load
(mm)
(kN)
113 160 204 304 409 584 338 416
13.7 21.7 31.6 58.8 91.7 132.1 80.2 98.1
*1 = tensile strenght 500N/mm2
Effect of anchor spacing - Tension Spacing (mm) 40 50 60 70 80 90 100 120 150 160 175 200 225 240 250 275 280 300 320 350 400 425 450 480 520
8 0,64 0,67 0,70 0,73 0,76 0,79 0,82 0,87 0,96 1,00
10 0,63 0,65 0,67 0,69 0,72 0,74 0,79 0,86 0,88 0,92 1,00
12
0,63 0,64 0,66 0,68 0,70 0,74 0,80 0,82 0,85 0,90 0,95 1,00
16
0,63 0,64 0,65 0,68 0,73 0,74 0,76 0,80 0,84 0,86 0,87 0,91 0,92 0,95 1,00
Effect of edge distance - Shear
Effect of edge distance - Tension
Stud/rebar diameter 20
0,63 0,65 0,68 0,70 0,71 0,74 0,77 0,79 0,80 0,83 0,84 0,86 0,88 0,92 1,00
24
0,63 0,65 0,66 0,68 0,71 0,74 0,76 0,77 0,80 0,80 0,82 0,85 0,88 0,94 0,97 1,00
30
0,63 0,64 0,65 0,68 0,70 0,72 0,73 0,75 0,76 0,78 0,80 0,83 0,88 0,90 0,93 0,96 1,00
Edge distance (mm) 40 50 60 70 80 90 100 110 120 140 160 180 200 225 250 260
Stud/rebar diameter 8 0,64 0,73 0,82 0,90 1,00
10 0,63 0,70 0,77 0,84 0,91 1,00
12
0,63 0,68 0,74 0,80 0,86 0,92 1,00
Revision 03-2021
74
16
0,63 0,67 0,71 0,76 0,80 0,89 1,00
20
0,63 0,66 0,70 0,77 0,84 0,91 1,00
24
0,64 0,68 0,76 0,84 0,92 1,00
30
0,63 0,66 0,72 0,78 0,86 0,94 1,00
Edge distance (mm) 40 50 60 70 80 90 100 110 125 140 160 180 200 225 250 280
Stud/rebar diameter 8 0,25 0,44 0,63 0,81 1,00
10 0,30 0,48 0,65 0,83 1,00
12
0,30 0,44 0,58 0,72 0,86 1,00
16
20
24
0,40 0,53 0,67 0,35 0,80 0,44 1,00 0,58 0,35 0,72 0,45 0,91 0,58 1,00 0,71 0,84 1,00
30
0,30 0,36 0,47 0,59 0,74 0,88 1,00
chemical anchors
chemical anchors
Vorpa PWI WINTER Styrene free polyester chemical anchor with European Technical Assesment for non cracked concrete for application in low ambient temperatures technical data
concrete
natural stone
solid brick
perforated brick
Characteristic and Design Load resistances based on characteristic bond strengths for hef 4d (minimum embedment) to 20d
Non cracked concrete Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
30
Tension (Nrk) 15,71 20,95 41,90 17,53 26,30 58,43 23,09 36,29 79,17 33,38 52,15 133,51 43,60 82,35 193,77 49,01 102,92 235,24 61,07 142,50 305,36
Shear (Vrk)
9,00
15,00
21,00
39,00
61,00
88,00
142,50
Cracked concrete
Design Resistance Recommended Load (kN) (kN) Tension (Nrd) 7,27 9,70 19,40 8,12 12,17 27,05 10,69 16,80 36,65 15,45 24,14 61,81 20,18 38,13 89,71 22,69 47,65 108,91 28,27 65,97 141,37
Shear (Vrd)
Tension (Nrec)
7,20
12,00
16,80
31,20
48,80
70,40
114,00
5,20 6,93 13,86 5,80 8,70 19,32 7,64 12,00 26,18 11,04 17,25 44,15 14,42 27,23 64,08 16,21 34,03 77,79 20,20 47,12 100,98
Characteristic Resistance (kN)
Shear (Vrec)
Tension (Nrk)
Shear (Vrk)
Design Resistance Recommended Load (kN) (kN) Tension (Nrd)
Shear (Vrd)
Tension (Nrec)
Shear (Vrec)
5,14
Not applicable
Not applicable
Not applicable
8,57
Not applicable
Not applicable
Not applicable
12,00
Not applicable
Not applicable
Not applicable
22,29
Not applicable
Not applicable
Not applicable
34,86
Not applicable
Not applicable
Not applicable
50,29
Not applicable
Not applicable
Not applicable
81,43
Not applicable
Not applicable
Not applicable
Nominal Embedment
(mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600
All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C
Bond Strength Factors Influence of concrete strength on combined pull out and concrete cone resistance (threaded bar) Concrete Strength N/mm2 (Mpa) non fessurato fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.97
1.00
1.02
1.04
1.07
1.10
1.12
1.15
Influence of environmental conditions in non cracked concrete (threaded bar)
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
M8
M10
M12
M16
M20
M24
M30
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.90
0.88
0.87
0.86
0.85
0.84
0.82
Examples of applications
Revision 03-2021
75
chemical anchors
chemical anchors
Vorpa PWI WINTER Styrene free polyester chemical anchor with European Technical Assesment for non cracked concrete for application in low ambient temperatures technical data
concrete
natural stone
solid brick
perforated brick
Characteristic and Design Load resistances REBAR based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non cracked concrete Characteristic Resistance (kN) Ø mm
8
10
12
16
20
25
28
32
Tension (Nrk) 13,30 17,73 35,47 15,91 23,86 53,03 19,84 31,18 68,04 27,87 43,54 111,47 32,23 60,88 143,26 38,80 81,48 193,99 46,30 115,76 231,52 54,05 135,11 270,23
Shear (Vrk)
13.95
21,45
31,05
55,50
86,55
135,00
168,75
220,95
Cracked concrete
Design Resistance Recommended Load (kN) (kN) Tension (Nrd) 6,33 8,44 16,89 7,58 11,36 25,25 9,45 14,85 32,40 13,27 20,73 53,08 15,35 28,99 68,22 18,48 38,80 92,38 22,05 55,12 110,25 25,74 64,34 128,68
Shear (Vrd)
9,30
14,30
20,70
37,00
57,30
90,00
112,50
147,30
Tension (Nrec) 4,52 6,03 12,06 5,41 8,12 18,04 6,75 10,61 23,14 9,48 14,81 37,91 10,96 20,71 48,73 13,20 27,71 65,98 15,75 39,37 78,75 18,38 45,96 91,91
Characteristic Resistance (kN)
Shear (Vrec)
Tension (Nrk)
Shear (Vrk)
Design Resistance Recommended Load (kN) (kN) Tension (Nrd)
Shear (Vrd)
Tension (Nrec)
Shear (Vrec)
6,64
Not applicable
Not applicable
Not applicable
10,21
Not applicable
Not applicable
Not applicable
14,79
Not applicable
Not applicable
Not applicable
26,43
Not applicable
Not applicable
Not applicable
41,21
Not applicable
Not applicable
Not applicable
64,29
Not applicable
Not applicable
Not applicable
80,36
Not applicable
Not applicable
Not applicable
105,22
Not applicable
Not applicable
Not applicable
Nominal Embedment
(mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 500 112 280 560 128 320 640
All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C
Bond Strength Factors Influence of concrete strength on combined pull out and concrete cone resistance (rebar) Concrete Strength N/mm2 (Mpa) non cracked fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.97
1.00
1.02
1.04
1.07
1.10
1.12
1.15
Influence of environmental conditions in non cracked concrete (rebar)
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
Ø8
Ø 10
Ø 12
Ø 16
Ø 20
Ø 25
Ø 28
Ø 32
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.90
0.90
0.88
0.88
0.86
0.86
0.84
0.84
76
chemical anchors
chemical anchors
Vorpa PE Polyester chemical anchor with European Technical Assesment for masonry
concrete
natural stone
solid brick
products group Approved for • ETAG 029 hollow Wall and masonry installations M8M10-M12 Also suitable for • natural stone • solid brick • perforated brick
rticale Sta in ve opic Thixotr
CALCULATION SOFTWARE
PE 300 PE 400
Tested for LEED compliancy ETAG 029 for masonry and hollow walls - Cat.c,w/d M10 Steel elements according to Table 2 Annex 5 ETA-11/0511
product code Code
Description
1125 PE 300 1002B PE 400
Content ml
Gun to be used
Shelf life
300 410
silicone type coaxial
12 months 12 months
Store upright
Examples of applications
77
To fix • non-structural fixings • light metal structures • light structural works • solar panel fixing • scaffolding links • floor reinforcement • construction joints • railings
perforated brick
chemical anchors
chemical anchors
Vorpa PE Polyester chemical anchor with European Technical Assesment for masonry
concrete
natural stone
solid brick
perforated brick
product information Characteristics • polyester chemical anchors injection system.European Technical Assessment for use in masonry. Suitable for concrete as well • suitable for medium loads for non-critical applications • fast working times for early loading in time sensitive applications • use in outdoor environments and fixing holes • extremely versatile in masonry, hollow, aerated concrete • crack and gap filling repairs in concrete vertical or horizontal
Approval/certifications/testing • 16/0907 - ETA ETAG 029 M8-M10-M12 hollow Wall / masonry Installations • ITB Approval (Poland) 0973W • LEED tested 2009 EQ. c4, 1 SCAQMD rule 1168 (2005) • VOC A+ Rating (Volatile Organic Content) Suggestion for use • performance based on clean holes. • HAMMER DRILLED – blown and then brushed with a stiff metal brush and blown again
installation sequence Clean the hole before the installation
On solid brick
On hollow brick
technical data Physical Properties Compressive Strength Flexural Strength Flexural Modulus Tensile Strength E Modulus VOC Content
N/mm2 (MPa)
Test Method
41,8 14,1 2589,6 7,4 4365,5 A+
EN ISO 604 / ASTM 695 EN ISO 178 / ASTM 790 EN ISO 178 / ASTM 790 EN ISO 527 / ASTM 638 EN ISO 527 / ASTM 638 -
*resin temperature must be at least 20°C Full cure 24 hours. All specifications based on supplied mixer Store at temperatures between +5 and +25 degrees, away from direct heat, rain and moisture
Minimum Curing Time Concrete Temperature
-10°C * -5°C * 5°C 15°C 25°C 35°C
Temperature Ranges
Gel-working Minimum curing Minimum curing time Time time in dry concrete in wet concrete
50 min 40 min 20 min 9 min 5 min 3 min
240 min 180 min 90 min 60 min 30 min 20 min
x2 x2 x2 x2 x2 x2
Range
Concrete Service Temperature
Range I Range II
-40°C to +40°C -40°C to +80°C
Maximum Long Term Maximum Short Concrete Temperature Term Concrete Temperature
+24°C +50°C
+40°C +80°C
Service temperature range: Range of ambient temperatures after installation and during the lifetime of the anchor. Short term temperature: Temperature within the service temperature range which vary over short intervals, e.g. day/ night cycles and freeze/than cycles. Long term temperature: Temperature, within the service temperature range, which will be approximately constant over significant periods of time
78
chemical anchors
chemical anchors
Vorpa PE Polyester chemical anchor with European Technical Assesment for masonry
concrete
natural stone
solid brick
perforated brick
technical data Typical characteristic and design resistance performance with 5.8 grade studding and associated installation data
Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
30
Tension (Nrk)
Shear (Vrk)
14,85 19,00 19,00 16,57 24,85 30,20 21,82 34,29 43,80 31,54 49,28 81,60 41,20 77,82 127,40 46,31 97,26 183,60 57,70 134,66 292,00
9,00
15,00
21,00
39,00
61,00
88,00
142,50
Design Resistance Recommended Load Characteristic distances (kN) (kN) (mm)
Min Edge and Spacing
Tension (Nrd)
(mm) (Cmin Smin)
6,87 9,17 12,70 7,67 11,50 20,10 10,10 15,88 29,20 14,60 22,81 54,40 19,07 36,03 84,90 21,44 45,03 122,40 26,71 62,34 194,50
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
114,00
Tension (Nrec) 4,91 6,55 9,07 5,48 8,22 14,36 7,22 11,34 20,86 10,43 16,30 38,86 13,62 25,73 60,64 15,31 32,16 87,43 19,08 44,53 138,93
Shear (Vrec)
Edge Spacing Edge (Ccr,N) (Scr,N) (Ccr,V)
5,14
80
160
80
40
8,57
100
200
90
50
12,00
120
240
110
60
22,29
160
320
125
80
34,86
200
400
180
100
50,29
225
450
220
120
81,43
260
520
280
150
Nominal Hole Hole Max Embedment diameterdiameter Torque concrete fixture (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600
(mm)
(mm)
(Nm)
10
9
10
12
12
20
14
14
40
18
18
80
24
22
120
28
26
160
35
32
200
All data is based on correct installation - see instructions No influence of edge and spacing Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d
Steel failure
Design resistance of resin with various stud strenghts and rebar Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
hef failure
embedment depth 60 6.9 7.7
60
depth mm
depth mm
5.8 grade steel studding
70 80 90 8.1 9.2 10.4 9.0 10.3 11.6 10.8 12.4 13.9 15.5 17.4 17.1 19.2
70
80
90
100 11.5 12.9 15.5 19.4 21.4 21.5
110 12.7 14.9 17.0 21.3 23.5 23.6 25.2
100
110
120 15.5 18.6 23.2 25.6 25.8 27.5 27.1 120
130 16.7 20.1 25.2 27.8 27.9 29.8 29.4 130
140 18.0 21.6 27.1 29.9 30.1 32.1 31.7 140
160 20.1 24.7 31.0 34.2 34.4 36.6 36.2 160
200 29.2 38.7 42.7 43.0 45.8 45.2 200
240
46.5 51.3 51.6 55.0 54.3 240
280
54.2 59.8 60.2 64.1 63.3 280
320
54.4 68.4 68.8 73.3 72.4 320
400
480
540
600
660
84.9 86.0 103.2 91.6 109.9 123.7 90.5 108.6 122.2 135.7 400 480 540 600 660
720
60
70
80
90
(kN)
110 156 189 281 398 569 695 860
12.7 20.1 29.2 54.4 84.9 122.4 159.1 194.5
hef failure
embedment depth 70 80 90 8.1 9.2 10.4 9.0 10.3 11.6 10.8 12.4 13.9 15.5 17.4 17.1 19.2
(mm)
720
8.8 grade steel studding
60 6.9 7.7
100 11.5 12.9 15.5 19.4 21.4 21.5
110 12.7 14.2 17.0 21.3 23.5 23.6 25.2
100
110
120 13.8 15.5 18.6 23.2 25.6 25.8 27.5 27.1 120
130 15.0 16.7 20.1 25.2 27.8 27.9 29.8 29.4 130
140 16.1 18.0 21.6 27.1 29.9 30.1 32.1 31.7 140
160 18.4 20.6 24.7 31.0 34.2 34.4 36.6 36.2 160
200 19.5 25.8 30.9 38.7 42.7 43.0 45.8 45.2 200
79
240 37.1 46.5 51.3 51.6 55.0 54.3 240
280
54.2 59.8 60.2 64.1 63.3 280
320
61.9 68.4 68.8 73.3 72.4 320
400
480
540
600
660
85.5 86.0 103.2 91.6 109.9 123.7 90.5 108.6 122.2 135.7 400 480 540 600 660
Fd,s design load
720
720
Fd,s design load
(mm)
(kN)
170 240 291 433 612 876 1069 1323
19.5 30.9 45.0 83.7 130.7 188.3 244.8 299.2
chemical anchors
chemical anchors
Vorpa PE Polyester chemical anchor with European Technical Assesment for masonry
concrete
natural stone
solid brick
perforated brick
technical data Design resistance of resin with various stud strenghts and rebar Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
10.9 grade steel studding
Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
60 6.9 7.7
70 80 90 8.1 9.2 10.4 9.0 10.3 11.6 10.8 12.4 13.9 15.5 17.4 17.1 19.2
70
80
90
100 11.5 12.9 15.5 19.4 21.4 21.5
110 12.7 14.2 17.0 21.3 23.5 23.6 25.2
100
110
120 13.8 15.5 18.6 23.2 25.6 25.8 27.5 27.1 120
130 15.0 16.7 20.1 25.2 27.8 27.9 29.8 29.4 130
140 16.1 18.0 21.6 27.1 29.9 30.1 32.1 31.7 140
160 18.4 20.6 24.7 31.0 34.2 34.4 36.6 36.2 160
200 25.8 30.9 38.7 42.7 43.0 45.8 45,2 200
240 37.1 46.5 51.3 51.6 55.0 54.3 240
280
54.2 59.8 60.2 64.1 63.3 280
320
61.9 68.4 68.8 73.3 72.4 320
400
480
540
600
660
85.5 86.0 103.2 91.6 109.9 123.7 90.5 108.6 122.2 135.7 400 480 540 600 660
720
70 80 90 8.1 9.2 10.4 9.0 10.3 11.6 10.8 12.4 13.9 15.5 17.4 17.1 19.2
70
80
90
100 11.5 12.9 15.5 19.4 21.4 21.5
100
(mm)
(kN)
236 334 405 603 852 1220 1489 1842
27.2 43.1 62.6 116.6 182.0 262.2 341.0 416.7
hef failure
embedment depth 60 6.9 7.7
110 12.7 14.2 17.0 21.3 23.5 23.6 25.2 110
120 13.7 15.5 18.6 23.2 25.6 25.8 27.5 27.1 120
130 16.7 20.1 25.2 27.2 27.9 29.8 29.4 130
140 18.0 21.6 27.1 29.9 30.1 32.1 31.7 140
160 20.6 24.7 31.0 34.2 34.4 36.6 36.2 160
200 21.7 30.9 38.7 42.7 43.0 45.8 45.2 200
240 31.6 46.5 51.3 51.6 55.0 54.3 240
280
54.2 59.8 60.2 64.1 63.3 280
320
58.8 68.4 68.8 73.3 72.4 320
400
480
540
85.5 86.0 103.2 80.2 90.5 98.1 400 480 540
600
600
660
660
Fd,s design load
720
A-70 stainless steel studding
60
depth mm
hef failure
embedment depth
60
depth mm
Steel failure
720
1 1 720
Fd,s design load
(mm)
(kN)
119 169 204 304 429 615 350 434
13.7 21.7 31.6 58.8 91.7 132.1 80.2 98.1
*1 = tensile strenght 500N/mm2
Ø
Ø
stud
hole
(mm)
(mm)
8 10 12 16 20 25 28 32
10 12 15 20 25 30 35 40
depth mm
High bond reinforcing bars Fyk = 500 N/mm2
hef failure
embedment depth 60 6.1 7.3
60
70 7.1 8.5 9.1
70
80 8.1 9.7 10.4 12.7 13.6
90 9.1 10.9 11.7 14.3 15.3
100 10.1 12.1 13.0 15.9 17.0 17.8
110 11.1 13.3 14.3 17.5 18.7 19.5 20.6
120 12.2 14.6 15.6 19.1 20.4 21.3 22.5
80
90
100
110
120
130 13.2 15.8 16.9 20.7 22.1 23.1 24.4 25.5 130
140 14.2 17.0 18.2 22.3 23.8 24.9 26.2 27.4 140
160 16.2 19.4 20.8 25.5 27.1 28.4 30.0 31.4 160
200 24.3 25.9 31.9 33.9 35.5 37.5 39.2 200
Examples of applications
80
240 31.1 38.2 40.7 42.6 45.0 47.1 240
280
44.6 47.4 49.7 52.5 54.9 280
320
51.0 54.3 56.8 60.0 62.7 320
400
500
560
640
720
67.9 71.0 88.8 75.0 93.7 104.9 78.4 98.0 109.8 125.5 400 500 560 640 720
800
800
Fd,s design load
(mm)
(kN)
216 281 379 549 805 1107 1429 1783
21.9 34.1 49.2 87.4 136.6 196.5 267.8 349.7
chemical anchors
chemical anchors
Vorpa PE Polyester chemical anchor with European Technical Assesment for masonry
concrete
natural stone
solid brick
perforated brick
technical data Characteristic and Design Load resistances based on characteristic bond strengths for hef 4d (minimum embedment) to 20d
Non cracked concrete Characteristic Resistance (kN) Ø mm
Tension (Nrk)
8
10
12
16
20
24
30
14,85 19,80 39,60 16,57 24,85 55,22 21,82 34,29 74,82 31,54 49,28 126,17 41,20 77,82 183,10 46,31 97,26 222,30 57,70 134,66 288,56
Cracked concrete
Design Resistance Recommended Load (kN) (kN)
Shear (Vrk)
Tension (Nrd)
Shear (Vrd)
6,87 9,17 18,33 7,67 11,50 25,56 10,10 15,88 34,64 14,60 22,81 58,41 19,07 36,03 84,77 21,44 45,03 102,92 26,71 62,34 133,59
9,00
15,00
21,00
39,00
61,00
88,00
142,50
Tension (Nrec) 4,91 6,55 13,10 5,48 8,22 18,26 7,22 11,34 24,74 10,43 16,30 41,72 13,62 25,73 60,55 15,31 32,16 73,51 19,08 44,53 95,42
7,20
12,00
16,80
31,20
48,80
70,40
114,00
Characteristic Resistance (kN)
Shear (Vrec)
Tension (Nrk)
Shear (Vrk)
Design Resistance Recommended Load (kN) (kN) Tension (Nrd)
Shear (Vrd)
Tension (Nrec)
Nominal Embedment
Shear (Vrec)
5,14
Not applicable
Not applicable
Not applicable
8,57
Not applicable
Not applicable
Not applicable
12,00
Not applicable
Not applicable
Not applicable
22,29
Not applicable
Not applicable
Not applicable
34,86
Not applicable
Not applicable
Not applicable
50,29
Not applicable
Not applicable
Not applicable
81,43
Not applicable
Not applicable
Not applicable
(mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600
All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C
Effect of anchor spacing - Tension Spacing (mm) 40 50 60 70 80 90 100 120 150 160 175 200 225 240 250 275 280 300 320 350 400 425 450 480 520
Effect of edge distance - Tension
Stud/rebar diameter 8 0,64 0,67 0,70 0,73 0,76 0,79 0,82 0,87 0,96 1,00
10 0,63 0,65 0,67 0,69 0,72 0,74 0,79 0,86 0,88 0,92 1,00
12
0,63 0,64 0,66 0,68 0,70 0,74 0,80 0,82 0,85 0,90 0,95 1,00
16
0,63 0,64 0,65 0,68 0,73 0,74 0,76 0,80 0,84 0,86 0,87 0,91 0,92 0,95 1,00
20
0,63 0,65 0,68 0,70 0,71 0,74 0,77 0,79 0,80 0,83 0,84 0,86 0,88 0,92 1,00
24
0,63 0,65 0,66 0,68 0,71 0,74 0,76 0,77 0,80 0,80 0,82 0,85 0,88 0,94 0,97 1,00
30
0,63 0,64 0,65 0,68 0,70 0,72 0,73 0,75 0,76 0,78 0,80 0,83 0,88 0,90 0,93 0,96 1,00
Edge distance (mm) 40 50 60 70 80 90 100 110 120 140 160 180 200 225 250 260
Effect of edge distance - Shear
Stud/rebar diameter 8 0,64 0,73 0,82 0,90 1,00
10 0,63 0,70 0,77 0,84 0,91 1,00
12
0,63 0,68 0,74 0,80 0,86 0,92 1,00
81
16
0,63 0,67 0,71 0,76 0,80 0,89 1,00
20
0,63 0,66 0,70 0,77 0,84 0,91 1,00
24
0,64 0,68 0,76 0,84 0,92 1,00
30
0,63 0,66 0,72 0,78 0,86 0,94 1,00
Edge distance (mm) 40 50 60 70 80 90 100 110 125 140 160 180 200 225 250 280
Stud/rebar diameter 8 0,25 0,44 0,63 0,81 1,00
10 0,30 0,48 0,65 0,83 1,00
12
0,30 0,44 0,58 0,72 0,86 1,00
16
20
24
0,40 0,53 0,67 0,35 0,80 0,44 1,00 0,58 0,35 0,72 0,45 0,91 0,58 1,00 0,71 0,84 1,00
30
0,30 0,36 0,47 0,59 0,74 0,88 1,00
chemical anchors
chemical anchors
Vorpa PE Polyester chemical anchor with European Technical Assesment for masonry
concrete
natural stone
solid brick
perforated brick
technical data Characteristic and Design Load resistances REBAR based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non cracked concrete Characteristic Resistance (kN) Ø mm
8
10
12
16
20
25
28
32
Tension (Nrk) 12,87 17,16 34,33 15,40 23,10 51,38 19,20 30,18 65,86 26,98 42,15 107,90 31,20 58,93 138,68 37,56 78,87 187,78 44,82 112,06 224,11 52,32 130,79 261,58
Shear (Vrk)
13.95
21,45
31,05
55,50
86,55
135,00
168,75
220,95
Cracked concrete
Design Resistance Recommended Load (kN) (kN) Tension (Nrd) 6,13 8,17 16,35 7,33 11,00 24,47 9,14 14,37 31,36 12,85 20,07 51,38 14,86 28,06 66,04 17,89 37,56 89,42 21,34 53,36 106,72 24,91 62,28 124,56
Shear (Vrd)
Tension (Nrec) 4,38 5,84 11,68 5,24 7,86 17,48 6,53 10,27 22,40 9,18 14,34 36,70 10,61 20,04 47,17 12,78 26,83 63,87 15,24 38,12 76,23 17,80 44,49 88,97
9,30
14,30
20,70
37,00
57,70
90,00
112,50
147,30
Characteristic Resistance (kN)
Shear (Vrec)
Tension (Nrk)
Shear (Vrk)
Design Resistance Recommended Load (kN) (kN) Tension (Nrd)
Shear (Vrd)
Tension (Nrec)
Shear (Vrec)
6,64 Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
10,21
14,79
26,43
41,21
64,29
80,36
105,22
Nominal Embedment
(mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 500 112 280 560 128 320 640
All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C
Bond Strength Factors Influence of concrete strength on combined pull out and concrete cone resistance (threaded bar) Concrete Strength N/mm2 (Mpa) non fessurato fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.97
1.00
1.02
1.04
1.07
1.10
1.12
1.15
Influence of environmental conditions in non cracked concrete (threaded bar)
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
M8
M10
M12
M16
M20
M24
M30
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.90
0.88
0.87
0.86
0.85
0.84
0.82
Influence of concrete strength on combined pull out and concrete cone resistance (rebar) Concrete Strength N/mm2 (Mpa) non cracked fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.97
1.00
1.02
1.04
1.07
1.10
1.12
1.15
Influence of environmental conditions in non cracked concrete (rebar)
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
Ø8
Ø 10
Ø 12
Ø 16
Ø 20
Ø 25
Ø 28
Ø 32
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.90
0.90
0.88
0.88
0.86
0.86
0.84
0.84
82
chemical anchors
chemical anchors
Vorpa Bitumphalte Bituminous adhesive bond
road floors asphalt
metals
cement
products group Suitable for • road floors • asphalt • cement • metals
BITUMPHALTE content 4,5 Kg
To fix • road marker, “cat’s eyes” • lane dividers, plastic cones • rubber on pavement
product information Characteristics • bituminous adhesive bond for the application of rubber and semirigid PVC to concrete, asphalt and metal • chemical composition bitumen, special solvent for quick drying, inert fillers selected resins, fibers, plasticizers, additives • any adjustment of the product is possible only before the drying
Suggestion for use and application • it is important surfaces to be treated being completely dry, clean and free from oil and dust flour or other. It’s ready to be used and should be applied with a spatula. Drying times vary depending on the type of support, the layer thickness realized and the ambient temperature • given to the high thixotropy, the application of the product is easy both horizontally and vertically. Tools, clothing and dirty hands can be cleaned with common synthetic thinners or nitro
product code and technical data Code Desciption
1177 Bitumphalte
Content kg
Working time min.
Curing time min
Cold flexibility
Service temperature range
Shelf life
4,5
5-7 min
15 min a 15°C 520 min a 20°C
-25°C ÷ +7°C
-5°C ÷ +40°C
24 months in original closed cup
Clean the surfaces before the installation
installation sequence
BITUMPHALTE 130
Full curing time 9 hours average value - standard
Specific weight at 20°C 1,10 kg/l ± 0,05 EN ISO 2811-1 Dry ressidue at 130°C 81% ± 5 EN ISO 3251 Elongation A 1400 ± 200 %
Examples of applications
83
Vorpa MULTISET PLUS Styrene free polyester pourable resin
concrete
natural stone
solid brick
marble
products group Suitable for • concrete • natural stone • solid brick • marble
MULTISET PLUS content 5 kg.
MULTISET PLUS content 1 kg.
To fix • anchoring threaded steel bolts into solid surfaces, typically cementitious surfaces • bedding-in coping stones, concrete units, steel, concrete or wooden posts • repairs to large cracks in concrete surfaces requiring a self-levelling characteristic or difficult to reach areas • traffic signs • crash-noise barriers on the road • bus shelters
product code and technical data Code
Description
1175 1174
Multiset plus 5 kg Multiset plus 1 kg
Content
Shelf life
base and hardener
12 months in original closed cup
Mechanical characteristics Tensile strength Tensile modulus Compressive strength Compressive strength Flexural strength Flexural modulus
Working and hardening times Base material temperature (C°) Working time (min) Loading time (min)
5 55 240
10 40 180
20 18 120
25 12 90
30 8 60
35 6 50
Standard ASTM D638 ASTM D638 ASTM D695 EN 196-1 ASTM D790 ASTM D790
Average value [N/mm2] 11,6 5045 76 76 21 1402
Physical properties Unsaturated polyester resin colour grey Specific weight: 1,65 kg/l a 20°C VOC: 6,0 g/l
installation sequence
B
chemical anchors
chemical anchors
A
A
B
A
A Clean the surfaces before the installation
Examples of applications
84
chemical anchors
chemical anchors
Vorpa MULTISET PLUS Styrene free polyester pourable resin
concrete
natural stone
solid brick
marble
product information Characteristics • multiset plus is a two component polyester mortar to fix threaded rod or rebar in a concrete floor, stone or plain brick. As a liquid product it can also be used to fill cracks. Ideal to fix playground equipment and bus shelters, traffic signs, crash and noise barriers on the road • fixing of rods or rebars in solid and hollow supports • useful to fill cavities, cracks or difficult access areas • high solid content • easy to apply • slight contraction • high mechanical and physical resistance
Suggestion for use e l’applicazione • remove water and dirt (dust and loose material) with a circular brush and a blower or with air pressure. Prepare the mixture of Multiset Plus with base and hardener. Mix both components thoroughly to reach a homogeneous mixture (if necessary, use a drill with a mixer). The items to be fastened must be clean. Spill the product from the base of the hole until 2/3 full. Insert the element to be fastened rotating, if necessary, keep the position with a suitable device. Wait the recommended working and drying times • before injection, verify the expiry date of the product, the support resistance and the ambient temperature • setting and any subsequent adjustment are only possible during working time • In unopened original packaging, one year from manufacturing date. • store the product in a ventilated place away from direct exposure to sunlight. Keep between 5ºC and 25ºC
technical data Performance data for rods into concrete Anchor Rod Class 5.8
M12 M16 M20 M24
Installation Drill diameter do
Embedment depth hef
[mm]
[mm]
[mm]
14 18 24 28
110 140 180 220
110 140 180 220
Resistance
Standard edge Standard anchor distance Ccr distance Scr
Admissible loads
Torque moment Tinst
Characteristics resistance NRk
Concrete C20/25
Concrete C20/25
[mm]
[N.m]
Tensile [kN]
Tensile [kN]
Shear [kN]
220 280 360 440
40 60 100 150
22,7 38,5 61,9 90,7
7,6 12,8 20,6 30,2
13,4 24,9 39,2 52,3
Safety factor for tension load 3,0
Performance data for rebar into concrete Bar diameter ds
Drill diameter do
[mm]
[mm]
12
16
14
18
16
20
20
25
25
32
Ultimate load Fs in C20/25 concrete High adherence 500 MPa steel rebar Embedment depth Tension load
10 ds [mm] [kN]
20 ds [mm] [kN]
30 ds [mm] [kN]
40 ds [mm] [kN]
45 ds [mm] [kN]
Lv Fs [C20/25] Lv Fs [C20/25] Lv Fs [C20/25] Lv Fs [C20/25] Lv Fs [C20/25]
120 7,6 140 10,0 160 12,7 200 19,9 250 31,8
240 15,3 280 20,0 320 25,4 400 39,7 500 63,6
360 22,9 420 30,0 480 38,1 600 59,6 750 95,4
480 30,6 560 40,1 640 50,9 800 79,5 1000 127,2
600 38,2 700 50,2 659 63,7 1000 99,6 1250 159,0
85
chemical anchors
chemical anchors
Vorpa POLYMER 700 Elastic hybrid adhesive sealant
marble granite
concrete masonry
natural stone
wood
boards and panels glass
PVC
polystyrene panels
products group Suitable for • granite, marble • concrete, masonry • natural stone • wood • boards and panels, glass • PVC • polystyrene panels
To fix • plant engineering • carpentry • marine • industry, boating • preparation of vans and campers
Elastic hybrid adhesive sealant for all building materials
Art. 1482 grey
Art. 1483 black
Art 1481 white
Elastic adhesive hybrid sealant
Fast solidification 30 Flexibility up to 50% minutes
Resistance to temperature -40°/+90°C
product code Code Description
1481 POLYMER 700 white 1482 POLYMER 700 grey 1483 POLYMER 700 black
Content ml
Gun to be used
Box pcs.
Shelf life
290
silicone type
24 pcs
12 months in original closed cup
Store upright Clean the surfaces before the installation
Examples of applications
Building
Benefits • UV ray stability • paintability • for wet surfaces • does not require PRIMER • antimold
Industry
Marine
86
chemical anchors
chemical anchors
Vorpa POLYMER 700 Elastic hybrid adhesive sealant
marble granite
concrete masonry
natural stone
wood
boards and panels glass
PVC
polystyrene panels
product information Characteristics • one-component elastic thixotropic adhesive sealant, based on hybrid polymers with silanic termination, Vorpa Polymer 700 combines the application advantages of a single-component with a very fast curing speed. During and after cross-linking, the hybrid adhesive is chemically neutral, non-corrosive and gives off little odor. After complete cross-linking, the product is permanently elastic, but nevertheless exhibits high mechanical strength • high adhesive strength on all surfaces, does not require primer, is resistant to UV rays and many chemical agents, has excellent elasticity and flexibility • it is free of isocyanates, solvents, acids and halogens. It is paintable and anti-mold • it does not stain marble or natural stones
Areas of use • Polymer 700 is suitable for plant engineering, carpentry, preparation of vans and campers, bonding of all materials present in the world of industry, boating and construction. Adheres to all building materials, even damp, such as brick, wood, concrete, stone, metals, ceramic, glass, to most plastics, PVC, ABS, PLEXIGLASS, sheet metal or fiberglass panels and delicate materials, such as mirror, marble, polycarbonate and polystyrene Suggestions for use • surfaces must be dry and clean. For cleaning use alcohol or similar solvents (check the compatibility of the surface with the solvent), the use of detergents or soap for cleaning the surfaces is not recommended. Open the cartridge and cut the inclined nozzle of the desired size. Apply with the gun in the right quantity. If necessary, apply adhesive tape to the edges of the joint to avoid smudging, smooth with a suitable spatula, for a better finish, wet the spatula with soap and water; remove the adhesive tape before hardening
technical data Characteristics Specific gravity at 25°C Consistency Time out of impression at 23°C/50%u.r. Tensile strength Elongation at break Modulus @ 100% Hardness Peeling resistance Resistance to temperature
Test Method
Values
ISO 1183-1 A ISO 7390, profile U 20
1,55 g/cm2 Mellow 10-15 min 2N/mm2 130% 1,9 N/mm2 55 3,2 N/mm -40°C/+90°C
ISO 8339 ISO 8339 ISO 8339 ISO 8339 ISO 34, method C
POLYMER 700 characteristics
87
chemical anchors
chemical anchors
Vorpa POLYMER 600 STEEL+ Elastic hybrid adhesive sealant
marble granite
concrete masonry
natural stone
wood
boards and panels glass
PVC
polystyrene panels
products group Suitable for • metal panels • concrete, masonry • natural stone • wood • boards and panels, glass • PVC • polystyrene panels
To fix • windows, doors • carpentry • facades, roofs • joints in buildings • metal joints of the skylights • paneling, sheet metal works
Sealing adhesive for gluing and sealing metal elements on facades, roofs, sheet metal works and metal carpentry
Art. 1477 dark brown
Benefits • resistant to UV ray and chemical and ambient agents • paintable • for wet substrates • no PRIMER needed • antimold • fast solidification
Art 1478 white-grey
product code Code Description
1477 POLYMER 600 steel+ dark brown 1478 POLYMER 600 steel+ white-grey
Content ml
Gun to be used
Box pcs.
Shelf life
290
silicone type
24 pcs
12 months in original closed cup
Store upright
Clean the surfaces before the installation
Examples of applications
Metal panels
Metal joints 88
Metal roofs
chemical anchors
chemical anchors
Vorpa POLYMER 600 STEEL+ Elastic hybrid adhesive sealant
marble granite
concrete masonry
natural stone
wood
boards and panels glass
PVC
polystyrene panels
product information Areas of use • Polymer 600 STEEL + is commonly used in the construction sector; for example, in sealing windows, doors, roofs, etc. • It can be used for the insulation of internal and external expansion joints in buildings. In the joints between wood and metal and in the metal joints of the skylights. Excellent adhesion on all roofing metals, sheet metal work and paneling
Characteristics • sealing adhesive for gluing and sealing metal elements on facades, roofs, sheet metal works and metal carpentry. Excellent adhesion on metals (aluminum, copper, galvanized steel, stainless steel, etc.), even damp materials such as brick, wood, cement, stone, ceramic, glass, for most plastics (PVC, ABS, plexiglass, etc. .) and delicate materials such as mirror, marble, polycarbonate and polystyrene • it has high adhesive strength on all surfaces, no primer needed • the product is resistant to UV rays and many chemical agents, has excellent elasticity and flexibility • free of isocyanates, solvents, acids and halogens, it can be painted, anti-mold and stains on marble or natural stones
Suggestions • surfaces must be dry and clean. For cleaning use alcohol or similar solvents (check the compatibility of the surface with the solvent), the use of detergents or soap for cleaning the surfaces is not recommended. Open the cartridge and cut the inclined nozzle of the desired size. Apply with the gun in the right quantity. If necessary, apply adhesive tape to the edges of the joint to avoid smudging, smooth with a suitable spatula, for a better finish, wet the spatula with soap and water; remove the adhesive tape before hardening
technical data Characteristics Specific gravity at 25°C Consistency Time out of impression at 23°C/50%u.r. Tensile strength Elongation at break Modulus @ 100% Hardness Peeling resistance Resistance to temperature
Test Method
Values
DIN 53 479 ISO 7390, profile U 20
1,60 g/cm2 Mellow 10-15 min 2N/mm2 125% 1,9 N/mm2 50 3,2 N/mm -40°C/+80°C
ISO 37 ISO 8339 ISO 37 Shore A ISO 34, method C
Examples of applications
89
chemical anchors
chemical anchors
Vorpa BITUM Elastic bituminous adhesive products group and information To fix • fills and seals gaps/cracks in most roofing applications • bonds to: concrete, roofing felt, lead, zinc, steel and masonry • for bedding tiles, slates and flashing into position • joint sealing on gutters and down pipes • sticking down loose roofing felt • joint sealing between corrugated asbestos cement and iron sheeting etc.
Suitable for • concrete • masonry • metal - copper surfaces
Characteristics • incorporates polymer additives to improve adhesion • can be applied in wet conditions, even under heavy rain • semi drying - remains permanently elastic beneath surface skin • high solids formulation - excellent gap filling properties without shrinkage • excellent external weathering properties • form ready to use thixotropic paste, black in colour • elastoplastic sealant adhesive based on bituminous elastomeric resins which adhere on most common building materials, even on wet surfaces, forming a flexible film • for bonding and sealing of roofs, insulation materials (excluded expanded PS), ceramic tiles, roofing tiles, polymeric surfaces (plastics) free of plasticizers • to seal and waterproof joints, cracks, various breakings, car body shells, etc. • adheres on concrete, zinc, wood, aluminium, metal sheet, etc • good occasional resistance to solvents, except turpentine and mineral oils • not overpaintable, not compatible with other sealants
BITUM
Suggestion for use • surfaces must be sound, clean and dry, free of oil and other contaminants. Apply with sealant gun in curbs. Complete curing depends on width and atmospheric conditions and may take from 12 hours to 2 days. Anyway, after some hours a good adhesion and consistence are obtained. Tools can be cleaned with mineral turpentine. Do not use on glass or PVC. Do not use internally
installation sequence
product code and technical data Code Description
Content ml
Curing time
23000 Bitum Vorpa
310
> 12 hours < 2 days
Temperature resistance
Application Temperature
Gun to be used
-35°C ÷ +110°C -5°C ÷ +30°C silicone type
Box pcs
12 pcs
Shelf life
24 months in original closen cup
Clean the surfaces before the installation Physical properties Specific weight 1,02 g/cm3 Flash point >39°C
90
chemical anchors
chemical anchors
Vorpa Battery tool 18.0V Extrusion tool for chemical anchors product information Characteristics of extrusion 18.0 Battery tool or chemical anchors co-axial up to 420ml • high thrust power thanks to the higher engine tool • trigger with speed control • anti-dripping, continuous and clean work • easy to carry thank to the apposite case containing extra battery pack and battery charger • Li-ion battery with low self-discharge rate • no memory effect, long life, light weight • LED auxiliary light
products group
Art.9120 Easypress 380/420
Li-ION TECHNOLOGY
Case including caulking gun and charge Easypress 380/420
Cartridges to be used with Easypress 380/420
Battery tool or chemical anchors co-axial up to 420ml Performances • maximum extrusion rate 5.0 mm/s • extrusion power 700 Kgf • voltage characteristics:18.0V 3.0Ah Li-ion 220V/230V
Professional use - Battery caulking gun To be used with 10:1 coaxial cartridges
Weight • cordless caulking gun: 3,20 kg • case including caulking gun and charger: 6,00 kg
product code Code
Description
Case content
To be used with
9120
Easypress 18.0V 380/420ml coaxial type
n° 1 Easy Press 18.0V n° 2 Battery pack 3.0Ah n° 1 Charger
VSM 400 - VSF 400 - VIN 400 PSF 400 - PE 400
9121
Extra Li-on battery pack 3.0Ah
Li-ION TECHNOLOGY
9111
Extra battery charger
91
Durable battery life for 500 chargedischarge cycles
chemical anchors
chemical anchors
Vorpa Pneumatic caulking gun Extrusion tool for chemical anchors product information Characteristics of the pneumatic gun • pressure switch for adjustable speed • no toil for long and repetitive applications • fast and uniform executions • for 10:1 cartridges art.1200 - art.1115 • for 3:1 cartridges art.1178 - art.1126
High quality pneumatic professional tool
products group
High quality professional coaxial caulking gun for 10:1 cartridges Characteristics of the pneumatic gun • supply pressure: max 6.8 bar • air consuption: max 40lt/min • length: 55 cm • weigth: 2 kg • for chemical anchors 380/420ml • for 10:1 cartridges Examples of cartridges to be used 380/420ml
Art.1200 pneumatic caulking gun 6.8bar
High quality professional bi-mixer caulking gun for 10:1 cartrridges Characteristics of the pneumatic gun • supply pressure: max 8 bar • air consuption: max 40lt/min • length: 65 cm • weigth: 3 kg • for chemical anchors 825ml • for 10:1 cartridges Examples of cartridges to be used 825ml
Art.1115 pneumatic caulking gun 8bar
High quality professional bi-mixer caulking gun for 3:1 cartrridges Characteristics of the pneumatic gun • supply pressure: max 8 bar • air consuption: max 40lt/min • extrusion capacity: 400 kg • length: 60 cm • weigth: 3 kg - 5kg • for chemical anchors 385-585-1400ml • for 3:1 cartridges
Examples of cartridges to be used 385-585-1400ml
Art.1178 -Art. 1126 pneumatic caulking gun 8bar
product code Code
Description
To be used with
1200 1115
Pneumatic caulking gun 10:1 - 6.8bar coaxial cartridges 380/420ml Pneumatic caulking gun 10:1 - 8bar side by side cartridges 825ml
VSM 400 - VSF 400 - VIN 400 PSF 400 - PE 400 V500 825
1178
Pneumatic caulking gun 3:1 - 8bar side by side cartridges 385-585ml
VE500 385 - VE500 585
1126
Pneumatic caulking gun 3:1 - 8bar side by side cartridges 1400ml
VE500 1400
92
chemical anchors
chemical anchors
Vorpa Manual caulking gun Extrusion tool for chemical anchors product code and information
Manual caulking gun - Bi-mixer for cartridges 3:1 Code Characteristics
1172
To be used with
• extrusion capacity 4 kN • weight 1,5Kg • to be used with cartridges 385/585ml • for 3:1 cartridges
metal
VE500 385/585
1004 • extrusion capacity 2,5 kN
• weight 1,0 Kg • to be used with cartridges 345ml • for 3:1 cartridges metal
1108 • extrusion capacity 5 kN
• weight1,0 Kg • to be used with cartridges 345ml • for 3:1 cartridges
VSF 345 nylon
Manual caulking gun - Bi-mixer for cartridges 1:1 Code Characteristics
To be used with
1203 • extrusion capacity 4 kN
• weight 1,5 Kg • to be used with cartridges 400ml • for 1:1 cartridges
VE100 400 VE100 600
1234 • extrusion capacity 4 kN
• weight 2 Kg • to be used with cartridges 600ml • for 1:1 cartridges
metal
Manual caulking gun - Coaxial for cartridges 10:1 Code Characteristics
To be used with
1101 • extrusion capacity 4,5 kN
• weight 1,0 Kg • to be used with cartridges 380/420ml • for 10:1 cartridges
metal
1107 • extrusion capacity 5 kN
• weight 1,0 Kg • to be used with cartridges 380/420ml • for 10:1 cartridges
VSM/VSF 400 PSF 400 - PE 4OO
nylon
1009 • extrusion capacity 2,5 kN
• weight 0,7 Kg • to be used with cartridges165ml-300ml • for 10:1 cartridges
VSM/VSF 300 PSF 165/300 PE 300 metal
93
chemical anchors
chemical anchors
Vorpa Easyfit cartridge adaptor Extrusion tool for silicone and chemical cartridges product information Characteristics of extrusion adaptor • Easyfit is an innovative patented device that allows to convert any battery electric drill into a powerful extrusion tool for silicone and chemical anchoring cartridges, without the need to use an expensive dedicated and separate battery tool • with Easyfit, the standard drill or work tool can be converted into a rapid extrusion tool and vice versa in seconds, so no worries about storing and loading separate battery packs. The use of the Easyfit adapter allows to significantly reduce timing for repeated extrusions and extended length applications • the Easyfit adapters are lightweight and fit into any conventional battery drill, can be fold and are easy to store
products group
Art 1341 EasyFit cartridge adaptor 280/300ml
Art 1342 EasyFit cartridge adaptor 380/420ml
Benefits of extrusion adaptor
Product code
• easy to store not in use • pressure control with speed-adjustable drills • standard fittings to fit any cordless drill • 12 months warranty • limited and fluid extrusions • separate battery-powered tools are not required • save time and energy
Code
Description
1341 1342
EASYFIT FOR CARTRIDGES 280/300ml EASYFIT FOR CARTRIDGES 380/420ml
PATENTED
Weight
MULTIPURPOSE
installation sequence
BREVETTATO
Insert the drill chuck into the hexagonal nozzle and tighten
Tighten the drill base with the belt
Insert the cartridge into the adapter
Adjust the tightening torque (10Nm)
Set the speed of the drill to 1
Extrude the product
94
0,72 1,34
chemical anchors
chemical anchors
Vorpa CVX Plastic perforated sleeve
perforated brick
hollow brick
perforated cement
products group Examples of application CVX
CVX plastic perforated sleeve for hollow materials
Examples of application CVX N
CVX N black plastic perforated sleeve to be used with THERMOISO PLUS on hollow materials for insulated walls
Clean the hole before the installation
installation sequence
Performance based on clean holes
product code and technical data Application on hollow materials with CVX Code
1006 1006E 51006 913 1017 915
Description
do mm
Lt mm
h1 mm
hef mm
Øb mm
CVX 12x50 CVX 12x60 CVX 12x80 CVX 16x85 CVX 16x130 CVX 20x85
12 12 12 16 16 20
50 60 80 80 130 85
60 70 90 90 140 95
50 60 80 80 130 85
up to 8 up to 8 up to 8 8 - 12 8 - 12 12 - 16
h ef h1
db
58732 58731
Description
do mm
Lt mm
h1 mm
hef mm
Øb mm
CVX N 16x85 CVX N 20x100
16 20
85 100
95 110
85 100
8 - 12 12 - 16
d0
Øb
Lt
Application on hollow materials with CVX N and THERMOISO PLUS on insulated walls Code
Tfix
Lb
Lt = Anchor length Lb = Stud length do = Hole diameter db = Internal sleeve thread h1 = Min. hole depth hef = Effective anchorage depth Øb = Stud diameter Tfix = Fixture thickness Stud length calculation: Lb = Lt +Tfix
95
chemical anchors
chemical anchors
Vorpa CVA - CVX mobile Plastic perforated sleeve
perforated brick
hollow brick
perforated cement
products group
CVA plastic perforated sleeve for hollow materials
CVX plastic perforated sleeve for hollow materials adjustable in depth
installation sequence Application on hollow materials with plastic perforated sleeve CVA
Application on hollow materials with plastic perforated sleeve CVX MOBILE
Tinst=4Nm
Tfix
Performance based on clean holes
Clean the hole before the installation
product code and technical data Application on hollow materials with perforated sleeve CVX MOBILE
Application on hollow materials with perforated sleeve CVA Code Description
do mm
Lt mm
h1 mm
hef mm
Øb mm
914 CVA 13x100 1914 CVA 15x100
14 16
100 100
110 110
100 100
M8-M10 M8-M12
hef
db
d0
Øb
Lt Lb
do Lt h1 h2 hef mm mm mm mm mm
Øb mm
Tfix min-max mm
51017 CVX 16x 330 18 330 135 340 130 M10-M12 20-200 h2
Tfix
h1
Code Description
Lt = Anchor length Lb = Stud length do = Hole diameter db = Internal sleeve thread h1 = Min. hole depth h2 = Max hole depth hef = Effective anchorage depth Øb = Stud diameter Tfix = Fixture thickness
h1 Tfix
d0
Stud length calculation: Lb = Lt +Tfix
Øb
hef Lt
Example of application CVA
Example of application CVX MOBILE
96
chemical anchors
chemical anchors
Vorpa CVH - CVK Steel perforated sleeve
perforated brick
hollow brick
perforated cement
products group
Ø15 - Ø17 CVH - CVH.A steel perforated sleeve for hollow materials with bent end
CVK steel perforated sleeve for hollow materials adjustable in depth with sheet metal shears
Ø22
installation sequence Application on hollow materials with steel perforated sleeve CVH-CVH.A db
Application on hollow materials with steel perforated sleeve CVK
Performance based on clean holes
Clean the hole before the installation
product code and technical data Application on hollow materials with steel perforated sleeve CVH-CVH.A Code
Description
do mm
h1 mm
Lt mm
Øb mm
2912 2913 2914 2915 2916 2917
CVH CVH CVH CVH CVH CVH
15 15 17 22 22 22
95 140 140 160 210 260
85 130 130 150 200 250
8-10 8-10 10-14 16-18 16-18 16-18
15x85 15x130 17x130 22x150 22x200 22x250
db
Tfix
h1
Lt = Anchor length Lb = Stud length do = Hole diameter Øb db = Internal sleeve thread h1 = Min. hole depth Øb = Stud diameter Tfix = Fixture thickness
d0
Lt Lb
Stud length calculation: Lb = Lt +Tfix
Application on hollow materials with steel perforated sleeve CVK Code
Description
do mm
db mm
Lt mm
Øb mm
2900 2901 2902
CVK 12x1000 CVK 16x1000 CVK 22x1000
12 16 22
9,5 12,5 18,5
1000 1000 1000
M8 M10-M12 M12-M16
Example of application CVH-CVK
97
chemical anchors
chemical anchors
Vorpa CVD Steel internal threaded sleeve
concrete
solid brick
perforated brick
hollow brick
perforated cement
products group
CVD steel internal threaded sleeve
installation sequence Performance based on clean holes
Application on hollow materials
Clean the hole before the installation
Application on solid materials
Usable for application on hollow brick with plastic sleeves and solid brick
product code and technical data Application with steel sleeve CVD
Lf
Code
Description
do mm
Lt mm
Lf mm
h1 mm
hef mm
db mm
1236 1237 1238
CVD 12x80 CVD 14x80 CVD 16x80
14 16 18
80 80 80
55 55 55
90 90 90
80 80 80
M8 M10 M12
db
Tfix
Øb
d0
Lt h1 hef
Lt = Anchor length do = Hole diameter db = Internal sleeve thread h1 = Min. hole depth hef = Effective anchorage depth Øb = Stud diameter Tfix = Fixture thickness Lf = Internal thread length Stud length calculation: Lb=Lt +Tfix
98
chemical anchors
chemical anchors
Vorpa CVF Steel threaded sleeve for asphalt surfaces
road floors asphalt
products group Characteristics • asphalt anchor system to be used with chemical anchors • easy and safe solution on asphalt and various base material surfaces • high performances. Fixture can be removed and replaced • no expansion stress in the base material. Versatile and flexible To fix • road signs, parking protection, bollards, fencing, shelters • edge protections, playgrounds, speed bumps
CVF
High performances on road floors and asphalt surfaces
installation sequence
Clean the hole before the installation
product code and technical data Performance based on clean holes
Application with steel sleeve CVF Code
52190 52191 52192 52193
Description
CVF 12x70 CVF 12x100 CVF 14x70 CVF 14x100
Fi mm
do mm
Lt mm
h1 mm
M10x20 M10x20 M12x20 M12x25
14 14 16 16
70 100 70 100
75 105 75 105
Pull out failure on asphalt surphaces *
Tension
Anchor length 70 mm Anchor length 100 mm
8 kN 15 kN
h1 Lt d0
M Lt do Fi h1
* The values may be different in relation to the consistency and heat of the asphalt surphace * 1kN≃100 Kg Examples of applications
99
= Anchor length = Hole diameter = Internal threadxlenth = Minimum hole length
chemical anchors
chemical anchors
Vorpa ACCESSORIES Fixing accessories products group Threaded bars • suitable on compact materials with CVB-CVD • ideal for various applications metal sleeves • the bars can be cut to size • suitable on hollow materials with CVX-CVA- • available also with nut and washer CVH plastic sleeves
• suitable for each applications with chemical anchors and mechanical anchors
Clean the hole before the installation
installation sequence
Performance based on clean holes
Example of applications for threaded bars with chemical anchors and plastic/metal sleeves
Application on compact material with CVB steel sleeve
Application on compact material with CVD steel sleeve
Application on hollow material with CVX plastic perforated sleeve
Application on hollow material with CVK steel perforated sleeve
Application on hollow material with CVA plastic perforated sleeve
Example of applications for threaded bars with VF CE chemical resin capsules
Example of applications for threaded bars with hammer-in resin capsules
S
5.8
A4 INOX 316
VFA INOX A4 A4 stainless steel anchor stud VFA hexagonal head with nut and washer Code
51920 51921 51922 51924 51926 51928
Description
Hexagonal Thread Stud thread mm length
VFA A4 M8 x 110 VFA A4 M10 x 130 VFA A4 M12 x 160 VFA A4 M16 x 190 VFA A4 M20 x 260 VFA A4 M24 x 300
*
5 7 8 12 14 14
M8 M10 M12 M16 M20 M24
110 130 160 190 260 300
VFM 5.8 steel anchor stud VFM hexagonal head with nut and washer
Ø hole mm without sleeve
Code
Description
10 12 14 18 24 28
2920 2921 2922 2924 2925 2926 2956
VFM M8 x 110 VFM M10 x 130 VFM M12 x 160 VFM M16 x 190 VFM M20 x 260 VFM M24 x 300 VFM M30 x 380
*
One driver tool in each box
ETAG 001-05 M8-M30 threaded bars for non cracked concrete
*
ETAG 001-05 M8-M30 threaded bars for non cracked concrete
Condition of ETA validity: use the threaded bars together with VORPA VF CE Resin capsules
100
Min hole Thread Stud depth mm length
80 90 110 125 170 210 275
M8 M10 M12 M16 M20 M24 M30
110 130 160 190 260 300 380
One driver tool in each box
Ø hole mm without sleeve
10 12 14 18 22 26 32
chemical anchors
chemical anchors
Vorpa ACCESSORIES Fixing accessories product code and technical data
8.8 VFG Steel anchor stud VFG with nut and washer Code
921 930753 90047 922 53413 50195 930091 1936 1934 1935 924 3925 930093 24532 926 51257 1000 928 956
Description
VFG M10x130 VFG M10x170 VFG M10x250 VFG M12x160 VFG M12x180 VFG M12x210 VFG M12x260 VFG M12x300 VFG M14x170 VFG M16x150 VFG M16x190 VFG M16x250 VFG M16x300 VFG M16x380 VFG M20x260 VFG M20x350 VFG M22x330 VFG M24x300 VFG M30x380
Thread
M10 M10 M10 M12 M12 M12 M12 M12 M14 M16 M16 M16 M16 M16 M20 M20 M22 M24 M30
VFG 8.8 8.8 steel anchor stud VFG with nut and washer Stud length
130 170 250 160 180 210 260 300 170 150 190 250 300 380 260 350 330 300 380
Ø hole mm without sleeve
12 12 12 14 14 14 14 14 16 18 18 18 18 18 24 24 26 28 40
Code
Description
9922 9924 9926 9928 9956
VFG 8.8 M12 x 160 VFG 8.8 M16 x 190 VFG 8.8 M20 x 260 VFG 8.8 M24 x 300 VFG 8.8 M30 x 380
*
Thread
Stud length
Ø hole mm without sleeve
M12 M16 M20 M24 M30
160 190 260 300 380
14 18 24 28 40
One driver tool in each box
ETAG 001-05 M8-M30 threaded bars for non cracked concrete
*
Condition of ETA validity: use the threaded bars together with VORPA VF CE Resin capsules
ZINCATO CALDO HOT DIP COATING VFG ZC hot dipped galvanized steel anchor stud VFG ZC with nut and washer Code
58025 58026 58027 58028 58029 58030
Description
VFG ZC M10 x 130 VFG ZC M12 x 160 VFG ZC M16 x 190 VFG ZC M20 x 260 VFG ZC M24 x 300 VFG ZC M30 x 360
Thread
Stud length
Ø hole mm without sleeve
M10 M12 M16 M20 M24 M30
130 160 190 260 300 360
12 14 18 24 28 40
A2 INOX 304
CVM Steel anchor stud CVM with nut and washer Code Description
911 916 51226 912 917 51232 918 58010 919 52268 52263 2918 52231 52518 52582 52607
CVM CVM CVM CVM CVM CVM CVM CVM CVM CVM CVM CVM CVM CVM CVM CVM
M8 x 75 M8 x 100 M8 x 150 M10 x 95 M10 x 110 M10 x 130 M10 x 140 M10 x 250 M12 x 115 M12 x 150 M12 x 165 M12 x 200 M12 x 250 M16 x 200 M16 x 300 M16 x 350
CVM INOX A2 A2 stainless steel anchor stud CVM with nut and washer
Thread
Stud length
Ø hole mm without sleeve
M8 M8 M10 M10 M10 M10 M10 M10 M12 M12 M12 M12 M12 M16 M16 M16
75 100 150 95 110 130 140 250 115 150 165 200 250 200 300 350
10 10 10 12 12 12 12 12 14 14 14 14 14 18 18 18
Code Description
9401 9402 9403 9404 9405 9406 3922 51178 51227 51229 53419 51253 51264 52014 52016 50286
101
CVM INOX A2 10x100 CVM INOX A2 10x110 CVM INOX A2 10x130 CVM INOX A2 10x140 CVM INOX A2 10x200 CVM INOX A2 10x250 CVM INOX A2 12x160 CVM INOX A2 12x170 CVM INOX A2 12x200 CVM INOX A2 12x230 CVM INOX A2 12x260 CVM INOX A2 16x200 CVM INOX A2 16x300 CVM INOX A2 16x350 CVM INOX A2 20x260 CVM INOX A2 20x350
Thread
Stud length
Ø hole mm without sleeve
M10 M10 M10 M!0 M10 M10 M12 M12 M12 M12 M12 M16 M16 M16 M20 M20
100 110 130 140 200 250 160 170 200 230 260 200 300 350 260 350
12 12 12 12 12 12 14 14 14 14 14 18 18 18 24 24
chemical anchors
chemical anchors
Vorpa ACCESSORIES Fixing accessories product code and technical data
4.8 4.8 threaded bar cm 100 Code
Description
1020 1021 1022 1023 1026 1024 1027 1025 1034 1035 1052 1053
M 6x1000 M 8x1000 M 10x1000 M 12x1000 M 14x1000 M 16x1000 M 18x1000 M 20x1000 M 22x1000 M 24x1000 M 27x1000 M 30x1000
DIN 975 Thread
M 6 M 8 M 10 M 12 M 14 M 16 M 18 M 20 M 22 M 24 M 27 M 30
Length cm
Ø hole mm without sleeve
100 100 100 100 100 100 100 100 100 100 100 100
8 10 12 14 16 18 22 24 26 28 32 40
8.8 8.8 threaded bar cm 100 Code
Description
90462 90463 90464 90490 90485 90484 90488 90489
M 8x1000 M 10x1000 M 12x1000 M 14x1000 M 16x1000 M 20x1000 M 24x1000 M 27x1000
DIN 975 Thread
M 8 M 10 M 12 M 14 M 16 M 20 M 24 M 27
Length cm
Ø hole mm without sleeve
100 100 100 100 100 100 100 100
10 12 14 16 18 24 28 32
4.8 4.8 threaded bar cm 300 Code
Description
50167 50173 50174 50175 50055
M 6x3000 M 8x3000 M 10x3000 M 12x3000 M 16x3000
DIN 975 Thread
M 6 M 8 M 10 M 12 M 16
A2 INOX 304
A2 stainless steel threaded bar cm 100
Length cm
Ø hole mm without sleeve
Code
Description
300 300 300 300 300
8 10 12 14 18
4060 4061 4062 4063 4065
M 6x1000 M 8x1000 M 10x1000 M 12x1000 M 16x1000
Thread
M 6 M 8 M 10 M 12 M 16
100 DIN 975 Length cm
Ø hole mm without sleeve
100 100 100 100 100
8 10 12 14 18
A4 INOX 316
S A4 stainless steel threaded bar cm 100 Code
Description
4069 4068 4076 4067 4078
M 8x1000 M 10x1000 M 12x1000 M 16x1000 M 20x1000
Thread
M 8 M 10 M 12 M 16 M 20
100 DIN 975
DRIVER TOOL
Length cm
Ø hole mm without sleeve
Code
Description
Internal thread S mm
Ø tang mm
100 100 100 100 100
10 12 14 18 24
945 946 947A 949 951 953 954 955
VFG M 8 VFG M 10 VFG M 12 VFG M 16 VFG M 20 VFG M 24 VFG M 27 VFG M 30
M8 M10 M12 M16 M20 M24 M27 M30
8 10 10 13 13 13 13 13
102
chemical anchors
chemical anchors
Vorpa VF CE Vinylester resin capsule spin-in type with European Technical Assesment for non cracked concrete
non-cracked concrete
products group
VF CE capsule
Approved for • M8-M10-M12 M16-M20-M24 threaded bars for non cracked concrete C20/25 - C50/60
To fix • starter bar applications • threaded studs • crush barriers • machinery - cladding • steel columns • guardrails • noise protection walls • balustrades
Also suitable for • natural stone
ETAG 001-05 M8-M24 threaded bars for non cracked concrete
installation sequence Standard cleaning
X2 X2 Premium cleaning
>6 BAR X2
X2 Clean the hole before the installation
product code Code
Description
Length mm
Shelf life
5900 5901 5902 5904 5906 5908
VF CE M 8 VF CE M 10 VF CE M 12 VF CE M 16 VF CE M 20 VF CE M 24
80 85 95 95 160 190
24 months 24 months 24 months 24 months 24 months 24 months
Minimum curing time and working time
Examples of applications
103
Concrete temperature (°C)
Minimum curing time (dry concrete) minutes
Minimum curing time (wet concrete) minutes
-5° - 0 0-5 5 - 10 10 - 20 > 20
360 180 90 40 20
720 360 180 80 40
chemical anchors
chemical anchors
Vorpa VF CE Vinylester resin capsule spin-in type with European Technical Assesment for non cracked concrete product information Characteristics • chemical anchors VF CE consist of a capsule containing a blend of resin, quarts, sand and special hardener encapsulated in a small glass capsule. The capsule is placed into a drilled hole previously cleaned and threaded rod is driven by machine with turning (simultaneous hammering and turning) • capsules can be set in either direction • quick curing and gel time • no waste of material. Safe and easy to use • chemical corrosion resistant • can be installed in wet concrete or in hole filled with water.product with ETA for non-cracked concrete • suitable for close edge applications, no tension on base material
Suggestion for use • avoid direct sunlight • clean out hole thoroughly before application • anchors to be tightened with calibrated torque wrench • see ETA for more details
technical data Specification data Hole diameter Hole diameter in fixture Minimum hole depth Minimum slab thickness Torque moment Minimum spacing Minimum edge distance
dO dfix hO hmin Tinst Smin Cmin
mm mm mm mm Nm mm mm
M8
M10
M12
M16
M20
M24
10 9 80 110 10 60 60
12 12 90 120 20 70 70
14 14 110 150 40 85 85
18 18 125 160 60 95 95
25 22 170 220 120 130 130
28 26 210 300 150 160 160
Examples of applications
104
non-cracked concrete
chemical anchors
chemical anchors
Vorpa VF CE Vinylester resin capsule spin-in type with European Technical Assesment for non cracked concrete
non-cracked concrete
technical data Performance data Threaded size Embedment depth Tension load Standard cleaning Characteristic resistance non cracked concrete C20/25 - (50/80°C) Design resistance ɤMC=1.8 Premium cleaning Characteristic resistance non cracked concrete C20/25 - (50/80°C) Design resistance ɤMC=1.8 Increasing factors C30/37 C40/50 C50/60 Shear load Steel Failure, Steel Grade 5.8 Characteristic resistance Design resistance ɤMs=1.3 Steel Failure, A4 - 70 Steel Grade Characteristic resistance Design resistance ɤMs=1.56 Bending Moment Steel Failure, Steel Grade 8.8 Characteristic resistance Design resistance ɤMs=1.3 Steel Failure, A4 - 70 Steel Grade Characteristic resistance Design resistance ɤMs=1.56
M8
M10
M12
M16
M20
M24
hef
mm
80
90
110
125
170
210
NRk,P
kN
9
12
16
25
40
60
NRd,s
kN
5
6,6
8,8
13,8
22,2
33,3
NRk,P
kN
12
16
25
35
60
75
NRd,s
kN
6,6
8,8
13,8
19,4
33,3
41,6
ψc ψc ψc
1,08 1,15 1,19
VRk,c VRd,c
kN kN
8 6,2
13 10
19 14,6
36 27,6
57 43,8
83 63,8
VRk,c VRd,c
kN kN
11 7
17 10,8
26 16,6
49 31,4
77 49,3
111 71,2
MRk,s MRa,s
kN kN
16 12,3
30 23
56 43
144 110
285 219
498 383
MRk,s VRd,s
kN kN
22 14
41 26,2
75 48
194 124,3
384 246
670 429,4
Spacing Edge distance (tension load)
CN mm 40 45 55 65 75 85 95 105 120 135 150 175 200 225 250 275 300 335
M8 0.55 0.58 0.63 0.69 0.76 0.82 0.89 0.96 1.00
Edge distance (shear)
M10 M12 M16 M20 M24
0.54 0.59 0.64 0.69 0.74 0.80 0.85 0.94 1.00
0.54 0.58 0.62 0.66 0.70 0.74 0.81 0.88 0.95 1.00
0.53 0.56 0.59 0.62 0.65 0.70 0.75 0.80 0.89 0.99 1.00
0.54 0.57 0.59 0.63 0.67 0.71 0.79 0.86 0.94 1.00
0.56 0.59 0.63 0.66 0.72 0.79 0.85 0.92 0.99 1.00
CV mm 40 50 60 70 80 90 100 120 140 160 180 200 220 260 320 360 405 450 490
M8 0.36 0.45 0.54 0.63 0.72 0.81 0.90 1.08 1.26 1.44
M10 M12 M16 M20 M24
0.38 0.46 0.54 0.62 0.69 0.77 0.92 1.08 1.23 1.38 1.54
0.37 0.44 0.50 0.56 0.62 0.75 0.87 1.00 1.12 1.25 1.37 1.62
105
0.35 0.40 0.44 0.49 0.59 0.69 0.79 0.89 0.99 1.09 1.28 1.58
0.37 0.41 0.49 0.57 0.66 0.74 0.82 0.90 1.07 1.31 1.48
0.43 0.50 0.58 0.65 0.72 0.79 0.94 1.15 1.30 1.46
S mm 40 50 60 70 80 90 100 120 140 160 180 200 220 260 320 360 405 450 490 550 600 670
M8 0.59 0.61 0.64 0.66 0.68 0.70 0.73 0.77 0.82 0.86 0.91 0.95 1.00
M10 M12 M16 M20 M24
0.60 0.62 0.63 0.65 0.67 0.69 0.73 0.77 0.81 0.85 0.88 0.92 1.00
0.59 0.61 0.62 0.64 0.66 0.69 0.72 0.75 0.78 0.81 0.84 0.90 1.00
0.59 0.60 0.61 0.62 0.65 0.67 0.70 0.72 0.75 0.77 0.82 0.90 0.94 1.00
0.59 0.60 0.62 0.64 0.66 0.68 0.70 0.73 0.77 0.83 0.87 0.91 0.96 1.00
0.61 0.63 0.64 0.66 0.68 0.70 0.73 0.79 0.82 0.86 0.91 0.94 1.00
chemical anchors
chemical anchors
Vorpa FOAM UNIVERSAL Self-expanding polyurethane foam products group and information To fix: • windows and doors frames • pipes insulation • fixing of Insulating panels • do it yourself works • electrical installations • fillings and finishing touches Characteristics • self-expanding one component polyurethane foam available in spray and gwun types, liquefied gas in pressure content • flammable Class B3 • it expands and hardens with air humidity • high adhesion to most of the building materials • high filling capacity, up to 45lt • after setting it can be treated mechanically • chemical agents, moulds and micro-organisms resistant • waterproof • sound-proofing and heat insulation properties
UNIVERSAL SPRAYTYPE 310
B3
UNIVERSAL SPRAY TYPE 750
UNIVERSAL GUN TYPE 750
for gun
Suggestion for use • shake before using. The surface of application must be well cleaned. Remove dust, oil and grease. Surfaces must be moistened with water. Apply upward. In presence of wide hollow materials it is suggested to repeat the application after setting. The application can be interrupted in any moment, leave the bottle turned on the gun till completely empty. Avoid any contact with sources of ignition, heat, flames
MULTIPURPOSE
FIRE RATED
Examples of applications
106
chemical anchors
chemical anchors
Vorpa FOAM UNIVERSAL Self-expanding polyurethane foam installation sequence Stability load bearing 18 hours
FOAM SPRAY TYPE
FOAM GUN TYPE
Clean the surfaces before the installation
product code and temperatures Code
Description
3600 FOAM UNIV.SPRAY TYPE 3601 FOAM UNIV.SPRAY TYPE 3602 FOAM UNIV.GUN TYPE
Content ml
Colour
Skin formation time min.
Can be cut min.
310 750 750
yellow yellow yellow
12-16 min 12-16 min 12-16 min
30-40 min 30-40 min 30-40 min
Temperature resistance C°
Application temperature C°
-50°C ÷ +90°C +5°C ÷ +20°C -50°C ÷ +90°C +5°C ÷ +20°C -50°C ÷ +90°C +5°C ÷ +20°C
Shelf life
18 months 18 months 18 months
Store upright
Examples of applications
FOAMPLUS UNIVERSAL Performance data Specific weight Dimensional stability Tensile strength
Pressure strength Thermal conductivity Flash point
25-30 kg/m3 max 2% 11 N/cm2
107
2 N/cm2 0,039 W/(mK) 400°C
chemical anchors
chemical anchors
Vorpa FOAM FOR ROOFING Self-expanding polyurethane foam products group and information To fix: • pipes insulation • roofing tiles fixings • fillings and finishing touches • fixing of Insulating panels • windows and doors frames • chimney flues insulation
FOAM FOR ROOFING GUN TYPE
B3 FIRE RATED
Characteristics • self-expanding one component polyurethane foam available in gun types • state: liquefied gas in pressure content • it expands and hardens with air humidity • suitable for repairing of roofing • high adhesion to most of the building materials • volume variation 0% • foam yeld (extruded) >40% • high filling capacity, up to 10 m2 • flammable Class B3 • after setting it can be treated mechanically • chemical agents, moulds and micro-organisms resistant • polymerize at low temperatures
FOR ROOFING
for gun
Suggestion for use • shake before using. The surface of application must be well cleaned. Remove dust, oil and grease. Surfaces must be moistened with water. Apply upward. In presence of wide hollow materials it is suggested to repeat the application after setting. The application can be interrupted in any moment, leave the bottle turned on the gun till completely empty. Avoid any contact with sources of ignition, heat, flames
Examples of applications
108
chemical anchors chemical anchors
chemical anchors
Vorpa FOAM FOR ROOFING Self-expanding polyurethane foam installation sequence Stability load bearing 18 hours
FOAM GUN TYPE
Clean the surfaces before the installation
product code and temperatures Code Description
Content ml
3604 FOAM ROOFING GUN TYPE 750
Colour
Skin formation time min.
Can be cut min.
grey
12-16 min
30-40 min
Temperature resistance C°
Application temperature C°
-50°C ÷ +90°C +5°C ÷ +20°C
Shelf life
18 months
Store upright
Examples of applications
FOAMPLUS FOR ROOFING Performance data Specific weight (extruded) Dimensional stability Tensile strength
Pressure strength Thermal conductivity Flash point
25-30 kg/m3 none 10 N/cm2
109
3 N/cm2 0,034 W/(mK) 400°C
chemical anchors
chemical anchors
Vorpa FOAM STOP FIRE B1 DOUBLE USE Self-expanding polyurethane foam fire rated B1 products group and information To fix: • installation of fire resistant door and window frames • fire and smoke resistant seals between partitions, ceilings and floors • sealing of cracks in roof constructions • sealing of cable runs, pipes in walls
FOAM DOUBLE USE GUN AND MANUAL TYPE STOP FIRE B1
B1 FIRE RATED
EI 180
STOP for gun
Characteristics • self-expanding one component polyurethane foam combined use spray and gun types • state: liquefied gas in pressure content • flammable class B1 DIN 4102-1 • formulated for applications in construction where resistance and selfextinguishing of materials is required • high adhesion to most of the building materials • after setting it can be treated mechanically • chemical agents, moulds and micro-organisms resistant • waterproof • sound-proofing and heat insulation properties. Acoustic reduction 60 dB Suggestion for use • shake before using. The surface of application must be well cleaned. Remove dust, oil and grease. Surfaces must be moistened with water. Apply upward. In presence of wide hollow materials it is suggested to repeat the application after setting. The application can be interrupted in any moment, leave the bottle turned on the gun till completely empty. Avoid any contact with sources of ignition, heat, flames
Examples of installations
110
chemical anchors
chemical anchors
Vorpa FOAM STOP FIRE B1 DOUBLE USE Self-expanding polyurethane foam fire rated B1 installation sequence Stability load bearing 18 hours
FOAM SPRAY TYPE
FOAM GUN TYPE
Clean the surfaces before the installation
product code and temperatures Code
Description
Content ml
3606
FOAM DOUBLE USE STOP FIRE B1 750
Skin formation Can be cut min. time min.
12-16 min
30-40 min
Temperature resistance C°
Application temperature C°
-50°C ÷ +90°C +5°C ÷ +20°C
Shelf life
15 months
Store upright
Examples of installations
FOAMPLUS STOP FIRE B1 Performance data Specific weight (extruded) Dimensional stability Tensile strength Pressure strength Thermal conductivity Flash point
Fire resistance EN 1366-4 25-30 kg/m3 none 8 N/cm2 2,5 N/cm2 0,034 W/(mK) 400°C
Depth joint mm 100 100 100 100 200 200 200 200 Width joint mm 40 30 20 10 40 30 20 10 EI min 45 45 60 60 120 120 150 180
111
chemical anchors
chemical anchors
Vorpa FOAM GRIP EPS Self-expanding polyurethane foam for EPS panels products group and information To fix: • external panels • roofing tiles fixings • thermal and sound insulation panels
GRIP FOAM FOR PANELS
THERMIC INSULATION
12m 2 SELF-EXTINGUISHING Output in square
Adhesive application on panels
HOURS
for gun
Characteristics • gun adhesive sticks to all common construction materials for filling and fixing gaps in exterior insulation finishing • the high output and powerful initial bond strength enable rapid, efficient panel mounting • the product is ready to use and requires no additional support structures • EIFS gun adhesive is used in place of mortar mixes • particulary suitable for bonding insulating panels, adheres on most of the building materials (PS, PU, bituminous). Does not adhere on PP, PE, TEFLON and silicons • protect from direct sunlight exposure. Overpaintable • installation yield: 12 sqm • it is not subject to ageing, but is susceptible to UV radiation damage. • excellent thermal and sound insulation properties • simple time-saving application • powerful initial bonding • low storage space requirement • clean application • flammable Class B2 according to DIN 4102
ENERGY SAVING
Suggestion for use • shake well before use. Apply fist on the edges of panels, then zig-zag spray on clean, dust- and greasefree surfaces using the specific gun, keeping the can upside down. (moistening surfaces improves adhesion, curing and structure). Wait about 2 minutes before install and align panels within 15 minutes. Delete possible big surfaces irregularity by applying mortar before placing panels. In case of rain or wind, protect panels as it takes 2 hours for the adhesive to reach the appropriate mechanical properties In case of further applications (over 24 hours after) immediately clean the erogation valve (and the gun) by using Foam Dissolver
Examples of applications
112
chemical anchors
chemical anchors
Vorpa FOAM GRIP EPS Self-expanding polyurethane foam for EPS panels installation sequence Stability load bearing 11 hours
Clean the surfaces before the installation
product code and temperatures Code
Description
3802 FOAM GRIP GUN TYPE
Content ml
Colour
750
yellow
Skin formation Can be cut min. time min. (3cm) min. (23°C-50%H.R)
12-16 min
40 min
Temperature resistance C°
Application temperature C°
-50°C ÷ +90°C +5°C ÷ +30°C
Shelf life
18 months
Store upright
Examples of applications
FOAMPLUS GRIP EPS Performance data Specific weight (extruded) Dimensional stability Post espansione
25-30 kg/m3 none 5%1
Tensile strength (BS 5241) Pressure strength (BS 53421) Thermal conductivity
113
1,1 N/cm2 4 N/cm2 0,03 W/(mK)
chemical anchors
chemical anchors
Vorpa FOAM CLEANER Foam gun cleaner products group and information Useful for uncured foam residue on: • can valves • PU-foam gun applicators • working clothes • working surfaces Characteristics • product designed for removing uncured polyurethane foams or adhesives • it is useful for cleaning of can valves and PU-foam gun applicators • it can be used with normal cans due to the attachable spray nozzle • suitable for removing uncured foam residue. The cleaner is excellent for degreasing metal surfaces before application of silicones and polyurethane. The propellant used is ozone friendly
FOAM CLEANER
Suggestion for use • screw Foamgun-Cleaner into the adapter of the gun. Put the trigger of the gun untill only clean solvent flows out the nozzle. Not suitable for cured foam. To clean other surfaces, normally spray product by the supplied valve Attention • pressurized container. Protect from sunlight and do not expose to temperatures exceeding 50°C. Do not pierce or burn, even after use. Do not spray on a naked flame or any incandescent material
installation sequence
Accessories
Foamplus gun PU PLUS professional model code 3785
Foamplus gun PU code 3784
product code and technical data Code Description Content ml
3786 FOAM CLEANER
500
Colour
Application temperature C°
trasparent +5°C ÷ +30°C
Shelf life
36 months
Store upright
Technical data Propellant Density Dynamic viscosity Contained water 114
propane/butane 850 Kg/m3 < 1 mPas < 0,2 %
CALCULanchor Suite
Vorpa Srl - Via San Leo, 5 Riccione ITALY www.vorpa.com - vorpa@vorpa.com
2
Heavy duty anchors
through-setting heavy duty anchors
Vorpa VEX+SEISMIC - Seismic category C1+C2 Heavy duty safety anchor with European Technical Assesment for cracked concrete and seismic zone
cracked concrete
heavy duty anchors
products group
*
Approved for • cracked and non-cracked VEX+SEISMIC concrete M8-M27 • reinforced and unreinforced normal weight concrete C20/25 - C50/60 VEX+SEISMIC • anchorage under static, quasi/ A4 STAINLESS STEEL static actions M8-M27 • seismic applications C1-C2 TR045 - M10 - M20 • anchorage under fire exposure in standard TR 020 R30-R120
FIXING IN SEISMIC
C1+C2 EAD 330232-00-0601 for cracked and uncracked concrete and seismic zone. Seismic Category C1-C2
R30-R120
CALCULATION SOFTWARE
To fix • parapets • steel beams • machine tools • industrial systems • heavy duty metal constructions • static, quasi/static anchorages • structural fixings
A4 INOX 316
*
product information Characteristics • special wedge anchor assembled with hex nut and washer with European Technical Assessment for cracked concrete and performance category C1-C2 under seismic action (M10 to M20, maximum anchor length 210 mm) • two effective anchorage depths for greater flexibility (M8 to M16, maximum anchor length 210 mm) • anchoring with the smaller effective anchorage depth reduces drilling and installation time • anchoring with the standard effective anchorage depth is suitable for the highest load limits • fire tested in compliance with DIN 4102-2. Fire resistance ratings R30–R120, for sprinkler system installations complying with VdS requirements (M10 to M16) • shock approval by the Swiss Federal office for Civil Protection
Installation • through-setting anchor Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Examples of applications
118
through-setting heavy duty anchors
Vorpa VEX+SEISMIC - Seismic category C1+C2 Heavy duty safety anchor with European Technical Assesment for cracked concrete and seismic zone
cracked concrete
installation sequence heavy duty anchors
Clean the hole before the installation
product code and technical data
VEX+SEISMIC zincplated hef
Code
32102 32103 32104 32105 32106 32107 32108 32109 32110 32111 32112 32113 32114 32115 32116 32117 32118 32119 32120 32121 32122 32123 32124 32125
Description
Lt mm
hef/ hefrid mm
doxh1/ doxh1rid mm
Tfix1/ Tfix2 mm
Tinst Nm
Ch
VEX+SEISMIC 8/15-26-80 VEX+SEISMIC 8/30-41-95 VEX+SEISMIC 8/50-61-115 VEX+SEISMIC 10/10-30-90 VEX+SEISMIC 10/15-35-95 VEX+SEISMIC 10/20-40-100 VEX+SEISMIC 10/30-50-110 VEX+SEISMIC 10/50-70-130 VEX+SEISMIC 10/75-95-155 VEX+SEISMIC 10/100-120-180 VEX+SEISMIC 12/10-30-105 VEX+SEISMIC 12/15-35-110 VEX+SEISMIC 12/20-40-115 VEX+SEISMIC 12/30-50-125 VEX+SEISMIC 12/50-70-145 VEX+SEISMIC 12/65-85-160 VEX+SEISMIC 12/85-105-180 VEX+SEISMIC 12/105-125-200 VEX+SEISMIC 16/15-35-135 VEX+SEISMIC 16/25-45-145 VEX+SEISMIC 16/50-70-170 VEX+SEISMIC 16/80-100-200 VEX+SEISMIC 20/30-165 VEX+SEISMIC 20/60-195
80 95 115 90 95 100 110 130 155 180 105 110 115 125 145 160 180 200 135 145 170 200 165 195
46/35 46/35 46/35 60/40 60/40 60/40 60/40 60/40 60/40 60/40 70/50 70/50 70/50 70/50 70/50 70/50 70/50 70/50 85/65 85/65 85/65 85/65 100/100/-
8x60/8x49 8x60/8x49 8x60/8x49 10x75/10x55 10x75/10x55 10x75/10x55 10x75/10x55 10x75/10x55 10x75/10x55 10x75/10x55 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 16x110/16x90 16x110/16x90 16x110/16x90 16x110/16x90 20x125/20x125/-
15/26 30/41 50/61 10/30 15/35 20/40 30/50 50/70 75/95 100/120 10/30 15/35 20/40 30/50 50/70 65/85 85/105 105/125 15/35 25/45 50/70 80/100 30/60/-
20 20 20 25 25 25 25 25 25 25 45 45 45 45 45 45 45 45 90 90 90 90 160 160
13 13 13 17 17 17 17 17 17 17 19 19 19 19 19 19 19 19 24 24 24 24 30 30
Examples of applications
119
h1 = Min. hole depth Lt = Anchor length do = Hole diameter Tfix = Fixture thickness Tinst = Torque Ch = Spanner hef = Effective anchorage depth
R30-R120 Only standard anchorage depth
through-setting heavy duty anchors
Vorpa VEX+SEISMIC - Seismic category C1+C2 Heavy duty safety anchor with European Technical Assesment for cracked concrete and seismic zone
cracked concrete
heavy duty anchors
product code and technical data
A4 INOX
VEX+SEISMIC INOX A4
316
hef
Code Description
Lt mm
hef/ hefrid mm
4250 4251 4252 4662 4675 4676 4677 4678 4679 4680 4681 4682 4683 4684 4685 4686 4687 4688 4689 4690 4691 4692 4693 4694 4695
80 95 115 90 95 100 110 130 155 180 105 110 115 125 145 160 180 200 125 135 145 170 200 165 195
46/35 46/35 46/35 60/40 60/40 60/40 60/40 60/40 60/40 60/40 80/50 80/50 80/50 80/50 80/50 80/50 80/50 80/50 97/65 97/65 97/65 97/65 97/65 100/100/-
VEX+SEISMIC A4 8/15-26-80 VEX+SEISMIC A4 8/30-41-95 VEX+SEISMIC A4 8/50-61-115 VEX+SEISMIC A4 10/10-30-90 VEX+SEISMIC A4 10/15-35-95 VEX+SEISMIC A4 10/20-40-100 VEX+SEISMIC A4 10/30-50-110 VEX+SEISMIC A4 10/50-70-130 VEX+SEISMIC A4 10/75-95-155 VEX+SEISMIC A4 10/100-120-180 VEX+SEISMIC A4 12/10-30-105 VEX+SEISMIC A4 12/15-35-110 VEX+SEISMIC A4 12/20-40-115 VEX+SEISMIC A4 12/30-50-125 VEX+SEISMIC A4 12/50-70-145 VEX+SEISMIC A4 12/65-85-160 VEX+SEISMIC A4 12/85-105-180 VEX+SEISMIC A4 12/105-125-200 VEX+SEISMIC A4 16/5-25-125 VEX+SEISMIC A4 16/15-35-135 VEX+SEISMIC A4 16/25-45-145 VEX+SEISMIC A4 16/50-70-170 VEX+SEISMIC A4 16/80-100-200 VEX+SEISMIC A4 20/30-165 VEX+SEISMIC A4 20/60-195
doxh1/ doxh1rid Tfix1/ Tfix2 Tinst mm mm Nm
Ch
8x60/8x49 8x60/8x49 8x60/8x49 10x75/10x55 10x75/10x55 10x75/10x55 10x75/10x55 10x75/10x55 10x75/10x55 10x75/10x55 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 16x110/16x90 16x110/16x90 16x110/16x90 16x110/16x90 16x110/16x90 20x125/20x125/-
13 13 13 17 17 17 17 17 17 17 19 19 19 19 19 19 19 19 24 24 24 24 24 30 30
Examples of applications
120
15/26 30/41 50/61 10/30 15/35 20/40 30/50 50/70 75/95 100/120 10/30 15/35 20/40 30/50 50/70 65/85 85/105 105/125 5/25 15/35 25/45 50/70 80/100 30/60/-
20 20 20 35 35 35 35 35 35 35 50 50 50 50 50 50 50 50 110 110 110 110 110 200 200
h1 = Min. hole depth Lt = Anchor length do = Hole diameter Tfix = Fixture thickness Tinst = Torque Ch = Spanner hef = Effective anchorage depth
R30-R120 Only standard anchorage depth
through-setting heavy duty anchors
Vorpa VEX+SEISMIC - Seismic category C1+C2 Heavy duty safety anchor with European Technical Assesment for cracked concrete and seismic zone
cracked concrete
technical data
Nominal drill hole diameter Torque moment Spanner Setting depth Minimum thickness of concrete member Drill hole depth Hole in the fixture
do Tinst SW hnom hmin h1 df
[mm] [Nm] [mm] [mm] [mm] [mm] [mm]
M8
M10
M12
M16
M20
M24
M27
8 20 13 46 100 60 9
10 25 17 60 120 75 12
12 45 19 70 140 90 14
16 90 24 85 170 110 18
20 160 30 100 200 125 22
24 200 36 115 230 145 26
28 300 41 125 250 160 30
M8
M10
M12
M16
M20
M24
M27
16 1,53 12,2 1,25 23 1,25 16 16 1,53 9,3 6,7 1,25
27 1,53 20,1 1,25 47 1,25 27 27 1,53 20 14 1,25
40 1,5 30 1,25 82 1,25 40 40 1,5 27 16,2 1,25
60 1,5 55 1,25 216 1,25 60 60 1,5 44 35,7 1,25
86 1,6 69 1,33 363 1,33 86 86 1,6 69 55,2 1,33
126 1,5 114 1,25 898 1,25 -
196 1,5 169,4 1,25 1331,5 1,25 -
12 5 5 2,3
16 9 9 3,6
25 16 16 10,2
35 25 25 13,8 1,22 1,41 1,55
1) 1) 36 22,4
1) 1) -
1) 1) -
46 138 69
60 180 90
70 210 105
85 255 127,5 7,2 10,1
100 300 150
115 345 172,5
125 375 187,5
Design method according to ETAG 001 part 1-2 Annex E Steel failure Characteristic resistance Tension Partial safety factor Shear Partial safety factor Bending moment Partial safety factor Tension loads C1 Tension loads C2 Partial safety factor Shear loads C1 Shear loads C1 Partial safety factor Pull-out failure Characteristics resistance non cracked concrete C20/25 Characteristics resistance cracked concrete C20/25 Characteristics resistance seismic performance C1 Characteristics resistance seismic performance C2 C30/37 Increasing factor C40/50 C50/60 Concrete cone failure and Anchorage depth
K factor cracked concrete K factor non-cracked concrete
NRk,s YMs VRk,s YMs M0Rk,s YMs NRk,s, C1 NRk,s, C2 YMs, seis VRk, seis, C1 VRk, seis, C2 YMs, seis
[kN] [kN] [Nm] [kN] [kN] [kN] [kN]
NRk,p,ucr NRk,p,cr NRk,seis,C1 NRk,seis,C2
[kN] [kN] [kN] [kN]
Ψc
[-]
hef scr,sp ccr,sp k k
[mm] [mm] [mm]
1) Pull out it not decisive
Examples of applications
121
heavy duty anchors
VEX+SEISMIC zincplated
through-setting heavy duty anchors
Vorpa VEX+SEISMIC - Seismic category C1+C2 Heavy duty safety anchor with European Technical Assesment for cracked concrete and seismic zone
cracked concrete
heavy duty anchors
technical data VEX+SEISMIC A4 stainless steel Nominal drill hole diameter Torque moment Spanner Standard sett. depth Minimum thickness of concrete member Drill hole depth Hole in the fixture
do Tinst SW hnom hmin h1 df
[mm] [Nm] [mm] [mm] [mm] [mm] [mm]
M8
M10
M12
M16
M20
M24
M27
8 20 13 46 100 60 9
10 35 17 60 120 75 12
12 50 19 70 140 90 14
16 110 24 85 160 110 18
20 200 30 100 200 125 22
24 290 36 125 250 155 26
-
M8
M10
M12
M16
M20
M24
M27
16 1,5 13 1,0 26 1,25 16 16 1,5 9,3 6,7 1,25
27 1,5 20 1,0 52 1,25 27 27 1,5 20 14 1,25
40 1,5 30 1,0 92 1,25 40 40 1,5 27 16,2 1,25
64 1,5 55 1,0 200 1,25 64 64 1,5 44 35,7 1,25
108 1,68 86 1,0 454 1,4 108 108 1,68 69 55,2 1,4
110 1,5 123,6 1,0 785,4 1,25 -
-
12 5 5 2,3
16 9 9 3,6
25 16 16 10,2
35 25 25 13,8 1,22 1,41 1,55
1) 1) 36 24,4
1) 40 -
-
46 138 69
60 180 90
70 210 105
85 255 127,5 7,2 10,1
100 300 150
125 375 187,5
-
Design method according to EAD 330232-00-0601 Steel failure Characteristic resistance Tension Partial safety factor Shear Partial safety factor Bending moment Partial safety factor Tension loads C1 Tension loads C2 Partial safety factor Shear loads C1 Shear loads C1 Partial safety factor Pull-out failure Characteristics resistance non cracked concrete C20/25 Characteristics resistance cracked concrete C20/25 Characteristics resistance seismic performance C1 Characteristics resistance seismic performance C2 C30/37 Increasing factor C40/50 C50/60 Concrete cone failure and Anchorage depth
K factor cracked concrete K factor non-cracked concrete
NRk,s YMs VRk,s YMs M0Rk,s YMs NRk,s, C1 NRk,s, C2 YMs, seis VRk, seis, C1 VRk, seis, C2 YMs, seis
[kN] [kN] [Nm] [kN] [kN] [kN] [kN]
NRk,p,ucr NRk,p,cr NRk,seis,C1 NRk,seis,C2
[kN] [kN] [kN] [kN]
Ψc
[-]
hef scr,sp ccr,sp k k
[mm] [mm] [mm]
1) Pull out it not decisive
Examples of applications
122
through-setting heavy duty anchors
Vorpa VEX+SEISMIC - Seismic category C1+C2 Heavy duty safety anchor with European Technical Assesment for cracked concrete and seismic zone
cracked concrete
technical data
Nominal drill hole diameter Torque moment Spanner Standard sett. depth Minimum thickness of concrete member Drill hole depth Hole in the fixture
M8
M10
M12
M16
8 20 13 35 80 49 9
10 35 17 40 80 55 12
12 50 19 50 100 70 14
16 110 24 65 140 90 18
M8
M10
M12
M16
50 60 40 185
50 100 65 180
50 160 100 185
65 170 170 65
Smin per C≥ Cmin per S≥
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
50 60 40 85
50 100 65 180
50 160 65 250
65 170 100 250
NRk,p,rid
[kN]
5
7,5
1)
1)
50
65
1)
1)
50
65
do Tinst SW hnom,rid hmin h1rid df
[mm] [Nm] [mm] [mm] [mm] [mm] [mm]
M20
M24
M27
M20
M24
M27
Minimum spacing and edge distance reduced anchorage depth Non cracked concrete Minimum spacing Minimum edge distance Cracked concrete Minimum spacing Minimum edge distance
Cracked concrete Pull-out failure Characteristic resistance C30/37 Increasing factor C40/50 C50/60 Concrete cone failure Anchorage depth K factor Non-cracked concrete Pull-out failure Characteristic resistance C30/37 Increasing factor C40/50 C50/60 Concrete cone failure Anchorage depth K factor
Smin per C≥ Cmin per S≥
1,22 1,41 1,55
Ψc hef, rid
35
40
k
7,2
NRk,p,rid
7,5
9 1,22 1,41 1,55
Ψc hef, rid
35
k
40 10,1
1) Pull out is not decisive ATTENTION: Partial technical data. Please consult ETA annexes to verify complete values.
Examples of applications
123
heavy duty anchors
VEX+SEISMIC reduced anchorage depth fixings
through-setting heavy duty anchors
Vorpa VEX+SEISMIC - Seismic category C1+C2 Heavy duty safety anchor with European Technical Assesment for cracked concrete and seismic zone
cracked concrete
heavy duty anchors
technical data VEX+SEISMIC Characteristic values for tension and shear load under fire exposure standard anchorage depth, cracked and non-cracked concrete C20/25 to C50/60, design acc. to TR 020 or CEN/TS 11924, Annex D M8 M10 M12 M16 M20 M24 M27 Tension load Steel failure Steel zinc plated R30 1,4 2,2 3,2 6,0 9,4 13,6 17,6 R60 1,1 1,8 2,8 5,2 8,2 11,8 15,3 NRk,s, fi [kN] R90 0,8 1,4 2,4 4,4 6,9 10,0 13,0 R120 0,7 1,2 2,2 4,0 6,3 9,1 11,8 Stainless steel A4 R30 3,8 6,9 11,5 21,5 33,5 48,2 R60 2,9 5,2 8,6 16 25,0 35,9 NRk,s, fi [kN] R90 2,0 3,5 5,6 10,5 16,4 23,6 R120 1,6 2,7 4,2 7,8 12,1 17,4 Shear load Steel failure without lever arm Steel zinc plated R30 1,6 2,6 3,8 7,0 11 16 20,6 R60 1,5 2,5 3,6 6,8 11 15 19,8 VRk,s, fi [kN] 6,5 10 15 19,0 R90 1,2 2,1 3,5 6,4 10 14 18,6 R120 1,0 2,0 3,4 Stainless steel A4 21,5 33,5 48,2 R30 3,8 6,9 11,5 16 25,0 35,9 R60 2,9 5,2 8,6 VRk,s, fi [kN] 10,5 16,4 23,6 R90 2,0 3,5 5,6 7,8 12,1 17,4 R120 1,6 2,7 4,2 Bending moment Steel failure with lever arm Steel zinc plated 15 29 50 75 R30 1,7 3,3 5,9 14 28 48 72 R60 1,6 3,2 5,6 o M Rk,s, fi [Nm] 14 27 47 69 R90 1,2 2,7 5,4 13 26 46 68 R120 1,1 2,5 5,3 Stainless steel A4 45,5 88,8 153,5 R30 3,8 9,0 17,9 33,9 66,1 114,3 R60 2,9 6,8 13,3 o M Rk,s, fi [Nm] 22,2 43,4 75,1 R90 2,1 4,5 8,8 16,4 32,1 55,5 R120 1,6 3,4 6,5
Examples of applications
124
through-setting heavy duty anchors
Vorpa VE.7CE M6-M16 Heavy duty anchor with European Technical Assesment for non cracked concrete
non cracked concrete
products group
EAD 330232-00-0601 for non cracked concrete
R30-R120
To fix • parapets • gates, stairs, profiles • steel beams • machine tools • industrial systems • heavy duty metal constructions • static, quasi/static anchorages
CALCULATION SOFTWARE
Only for M20
product information Characteristics • special wedge anchor assembled with hex nut and washer with European Technical Assessment for non cracked concrete • fire tested in compliance with TR020. Fire resistance ratings R30– R120 for M20 sizes • reduced hole diameter • suitable for through-setting applications in concrete • thread diameter and hole diameter are the same • reinforced anchor’s head to avoid damaging the thread during the installation
Installation • through-setting anchor Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
installation sequence
Clean the hole before the installation
Examples of applications
125
heavy duty anchors
VE.7CE
Approved for • non-cracked concrete C20/25-C50/60 • anchorage under static, quasi/ static actions M6-M20 • anchorage under fire exposure in standard TR 020 R30-R120 only for M20 size
through-setting heavy duty anchors
Vorpa VE.7CE M6-M16 Heavy duty anchor with European Technical Assesment for non cracked concrete
non cracked concrete
heavy duty anchors
product code and technical data
VE.7CE hef
Code
Description
Lt mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
4637 4638 4640 4641 4642 4643 4644 4645 4646 4696 4647 4648 4649 4650 4651 4652 4653 4654 4655 4656 4657 4658 4659
VE.7CE 6/10-55 VE.7CE 6/20-65 VE.7CE 8/1-65 VE.7CE 8/15-80 VE.7CE 8/30-95 VE.7CE 8/50-115 VE.7CE 8/65-130 VE.7CE 10/1-75 VE.7CE 10/15-90 VE.7CE 10/25-105 VE.7CE 10/45-120 VE.7CE 10/75-150 VE.7CE 12/10-90 VE.7CE 12/15-110 VE.7CE 12/25-120 VE.7CE 12/45-140 VE.7CE 12/65-160 VE.7CE 12/85-180 VE.7CE 16/5-125 VE.7CE 16/20-140 VE.7CE 16/30-150 VE.7CE 16/55-175 VE.7CE 16/100-220
55 65 65 80 95 115 130 75 90 105 120 150 90 110 120 140 160 180 125 140 150 175 220
6 6 8 8 8 8 8 10 10 10 10 10 12 12 12 12 12 12 16 16 16 16 16
55 55 65 65 65 65 65 70 70 70 70 70 90 90 90 90 90 90 110 110 110 110 110
10 20 1 15 30 50 65 1 15 25 45 75 10 15 25 45 65 85 5 20 30 55 100
5 5 15 15 15 15 15 25 25 25 25 25 45 45 45 45 45 45 100 100 100 100 100
10 10 13 13 13 13 13 17 17 17 17 17 19 19 19 19 19 19 24 24 24 24 24
VE.7CE M6 - M16 The letter on the top of the head indicated the anchors length.
Letter ≥ < Letter ≥ <
A 50 N 170 180
B 50 60 O 180 190
C 60 70 P 190 200
D 70 80 Q 200 220
E 80 90 R 220 240
F 90 10 S 240 260
G 100 110 T 260 280
H 110 120 U 280 300
I 120 130 V 300 320
Examples of applications
126
J 130 140 W 320 340
K 140 150 X 340 360
L 150 160 Y 360 380
M 160 170 Z 380 400
h1 = Min. hole depth Lt = Anchor length do = Hole diameter Tfix = Fixture thickness Tinst = Torque Ch = Spanner hef = Effective anchorage depth
through-setting heavy duty anchors
Vorpa VE.7CE M6-M16 Heavy duty anchor with European Technical Assesment for non cracked concrete
non cracked concrete
technical data VE.7CE M6-M16
M8
M10
M12
M16
d hef do h1 df Tinst Scr,N Ccr,N Smin Cmin hmin
mm mm mm mm mm mm Nm mm mm mm mm
6 40 6 55 7 5 120 60 60 60 100
8 45 8 65 9 15 135 70 67,5 67,5 100
10 51 10 70 12 25 155 80 76,5 76,5 105
12 66 12 90 14 45 200 100 99 99 135
16 80 16 110 18 100 240 120 120 120 160
Nrk,P C20/25
KN
4 1,08 1,15 1,19
9 1,08 1,15 1,19
12 1,08 1,15 1,19
16 1,08 1,15 1,19
30 1,08 1,15 1,19
VRk,S C20/25 Shear failure KN MRK,S Bending moment Nm Values where the reduction factor γ is included (Design loads) Nrk,P Pull out failure KN VRk,S Shear failure KN MRK,S Bending moment Nm Recommended loads N Pull out failure KN T Shear failure KN M Bending moment Nm
4 6,1
7,3 15
11,6 29,9
16,9 52,4
31,4 133,2
2,6 3,2 4,8
6 5,8 12
8 9,2 23,9
8,8 13,5 41,9
16,6 25,1 106,5
1,8 2,2 3,4
4,2 4,1 8,5
5,7 6,5 17
6,2 9,6 29,9
11,8 17,9 76
Anchor diameter Effective anchorage depth Drill hole diameter Drill hole depth Hole diameter in the fixture Torque moment Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum thickness member Characteristic values Pull out failur non cracked concrete Ψc C30/37 Ψc C40/50 Ψc C50/60
Examples of applications
127
heavy duty anchors
M6
through-setting heavy duty anchors
Vorpa VE.7CE M20 Heavy duty anchor with European Technical Assesment for non cracked concrete
non cracked concrete
heavy duty anchors
product code and technical data
VE.7CE zincplated M20
R30-R120 Code
Description
Lt mm
hef/ hef rid mm
do h1/ do h1 rid mm
Tfix / Tfix2 mm
Tinst Nm
Ch
4660 4670 4672
VE.7CE 20/5 -27-150 VE.7CE 20/35 -57-180 VE.7CE 20/95 -117-240
150 180 240
100/78 100/78 100/78
20x130/20x110 20x130/20x110 20x130/20x110
5/27 35/57 95/117
200 200 200
30 30 30
hef
VE.7CE M20 The letter on the top of the head indicated the anchors length.
A Letter B 38,1 50,8 ≥ 50,8 63,5 < N Letter O 203,2 215,9 ≥ 215,9 228,6 <
C 63,5 76,2 P 228,6 241,3
D 76,2 88,9 Q 241,3 254,0
E 88,9 101,6 R 254,0 279,4
F 101,6 114,3 S 279,4 304,8
G 114,3 127,0 T 304,8 330,2
H 127,0 139,7 U 330,2 355,6
I 139,7 152,4 V 355,6 381,0
J 152,4 165,1 W 381,0 406,4
K 165,1 177,8 X 406,4 431,8
L 177,8 190,5 Y 431,8 457,2
h1 = Profondità minima foro Lt = Lunghezza tassello do = Diametro foro tfix = Spessore fissabile Tinst = Coppia di serraggio Ch = Chiave hef = Profondità di ancoraggio
M 190,5 203,2 Z 457,2 483,0
VE.7CE M20 Installation data Performance data Effective anchorage depth Reduced anchorage depth Drill hole diameter Drill hole diameter in the fixture Drill hole depth Torque moment Width across nut
M20 hef hef,red do do h1 Tinst SW
mm mm mm mm mm Nm mm
100 - - 78 20 20 22 22 130 110 200 200 30 30
Spacing and edge distance Effective anchorage depth Characteristic spacing Characteristic edge distance Minimum spacing Minimum edge distance Minimum thickness of concrete slab
hef Scr,N Ccr,N Smin Cmin hmin
mm mm mm mm mm mm
100 78 300 234 150 117 105 140 125 140 200 160
kN Nm
M20 * 1,22 1,41 1,55 69 363
Characteristic values - Effective anchorage depth (hef) Pull out failure Ψc C30/37 C25/30 Ψc C40/50 Ψc C50/60 Shear failure V Bending moment M Design loads - Effective anchorage depth (hef) Pull out failure Shear failure Bending moment Recommended loads Pull out failure Shear failure Bending moment
N V M
kN kN Nm
N V M
kN kN Nm
* Pull-out failure is not decisive
128
M20 * 51,8 272,9 M20 * 37 194,9
through-setting heavy duty anchors
Vorpa VE.7CE M16 extra long Heavy duty anchor with European Technical Assesment for non cracked concrete
non cracked concrete
product code and technical data
hef
Code
Description
Lt mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
2227 2228 2229 2230 2235 2236 2237
VE.CE 7 16/125-240 VE.CE 7 16/145-260 VE.CE 7 16/165-280 VE.CE 7 16/185-300 VE.CE 7 16/215-330 VE.CE 7 16/245-360 VE.CE 7 16/280-400
240 260 280 300 330 360 400
16 16 16 16 16 16 16
120 120 120 120 120 120 120
125 145 165 185 215 245 280
100 100 100 100 100 100 100
24 24 24 24 24 24 24 h1 = Min. hole depth Lt = Anchor length do = Hole diameter Tfix = Fixture thickness Tinst = Torque Ch = Spanner hef = Effective anchorage depth
Note: All anchors Ø16 whose length is more than 220 mm will be assembled with DIN 9021 washer Max Tfix = 280 mm
VE.CE7 M16 extra long VE.CE7 EXTRA LONG Installation data Anchor diameter Anchor length Effective anchorage depth Fixture thickness Drill hole diameter Drill hole depth Drill hole diameter in the fixture Torque moment Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum thickness member Characteristic values Pull out failure kN (1kN≃100kg) non-cracked concrete Ψc C30/37 Ψc C40/50 Ψc C50/60 Shear failure Bending moment Values with reduction factor γ (Design loads) Pull out failure Shear failure Bending moment Recommended loads Pull out failure Shear failure Bending moment
d L
mm mm
M16 EXTRA LONG 16 221-400
hef Tfix do h1 df Tinst Scr,N Ccr,N Smin Cmin hmin
mm mm mm mm mm Nm mm mm mm mm mm
75,8 280 16 120 18 100 270 135 96 128 200
Nrk,P C20/25
KN
25 1,22 1,41 1,55
VRk,S C20/25 MRK,S
KN Nm
13,5 166
Nrk,P VRk,S MRK,S
KN KN Nm
13,9 10,8 132,8
N T M
KN KN Nm
9,9 7,7 75
129
heavy duty anchors
VE.CE7 M16 extra long
through-setting heavy duty anchors
Vorpa VE.CE7 INOX A4 Heavy duty anchor with European Technical Assesment for non cracked concrete
non cracked concrete
heavy duty anchors
products group
VE.CE7 INOX A4
EAD 330232-00-0601 for non cracked concrete
R30-R120
CALCULATION SOFTWARE
Approved for • non-cracked concrete C20/25-C50/60 • anchorage under static, quasi/ static actions M6-M20 • anchorage under fire exposure in standard TR 020 R30-R120
To fix • parapets • gates, stairs, profiles • steel beams • machine tools • industrial systems • heavy duty metal constructions • static, quasi/static anchorages
A4 INOX 316
product information Characteristics • special wedge anchor assembled with hex nut and washer with European Technical Assessment for non cracked concrete • fire tested in compliance with TR020. Fire resistance ratings R30– R120 • reduced hole diameter • suitable for through-setting applications in concrete • thread diameter and hole diameter are the same • reinforced anchor’s head to avoid damaging the thread during the installation
Installation • through-setting anchor Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
installation sequence
Clean the hole before the installation
Examples of applications
130
through-setting heavy duty anchors
Vorpa VE.CE7 INOX A4 Heavy duty anchor with European Technical Assesment for non cracked concrete
non cracked concrete
product code and technical data heavy duty anchors
A4 INOX
VE.CE7 INOX A4
316
hef
*
Code
Description
Lt mm
do mm
h1 /h1rid mm
tfix / tfix2 mm
Tinst Nm
Ch
4621 4622 4623 4625 4626 4627 4698 4628 4629 4630 4631 4697 4663 4632 4633 4634 4635 4636
VE.CE7 A4 8/10-19-75 VE.CE7 A4 8/30-39-95 VE.CE7 A4 8/55-64- 120 VE.CE7 A4 10/15-21-90 VE.CE7 A4 10/45-51-120 VE.CE7 A4 10/70-76-145 VE.CE7 A4 10/100-106-175 VE.CE7 A4 12/5-75 VE.CE7 A4 12/15-30-110 VE.CE7 A4 12/30-45-125 VE.CE7 A4 12/50-65-145 VE.CE7 A4 12/85-100-180 VE.CE7 A4 12/105-120-200 VE.CE7 A4 16/13-115 VE.CE7 A4 16/30-48-150 VE.CE7 A4 16/60-78-180 VE.CE7 A4 20/5-27-150 VE.CE7 A4 20/35-57-180
75 95 120 90 120 145 175 75 110 125 145 180 200 115 150 180 150 180
8 8 8 10 10 10 10 12 12 12 12 12 12 16 16 16 20 20
65/55 65/55 65/55 70/65 70/65 70/65 70/65 90/75 90/75 90/75 90/75 90/75 90/75 110/95 110/95 110/95 130/110 130/110
10/19 30/39 55/64 15/21 45/51 70/76 100/106 -/5 15/30 30/45 50/65 85/100 105/120 -/13 30/48 60/78 5/27 35/57
15 15 15 25 25 25 25 50 50 50 50 50 50 100 100 100 160 160
13 13 13 17 17 17 17 19 19 19 19 19 19 24 24 24 30 30
h1 = Min. hole depth Lt = Anchor length do = Hole diameter Tfix = Fixture thickness Tinst = Torque Ch = Spanner hef = Effective anchorage depth
*Not covered by ETA
Attention: The use of the Tfix2 causes reduced effective anchorage depth and reduced loads
VE.CE7 INOX A4 Installation data Performance data Effective anchorage depth Reduced anchorage depth Drill hole diameter Drill hole diameter in the fixture Drill hole depth Torque moment Width across nut
hef hef,red do do h1 Tinst SW
Spacing and edge distance Effective anchorage depth hef Characteristic spacing Scr,N Characteristic edge distance Ccr,N Minimum spacing Smin Minimum edge distance Cmin Minimum thickness of concrete slab hmin
M8
M10
M12
M16
M20
mm mm mm mm mm Nm mm
44 - - 351) 8 8 9 9 65 55 15 15 13 13
48 - - 42 10 10 12 12 70 65 25 25 17 17
65 - - 50 12 12 14 14 90 75 50 50 19 19
80 - - 64 16 16 18 18 110 95 100 100 24 24
100 - - 78 20 20 22 22 130 110 160 160 30 30
mm mm mm mm mm mm
44 351) 132 105 66 52,5 35 60 45 60 100 80
48 42 144 126 72 63 45 55 55 65 100 100
65 50 195 150 97,5 75 60 100 70 100 130 100
80 64 240 192 120 96 80 110 80 110 160 130
100 78 300 234 150 117 100 140 100 140 200 160
Characteristic values - Effective anchorage depth (hef) Pull out failure Ψc C30/37 C25/30 Ψc C40/50 Ψc C50/60 Shear failure V kN Bending moment M Nm
M8 9 1,22 1,41 1,55 12 24
M10 12 1,22 1,41 1,55 19 49
M12 20 1,22 1,41 1,55 27 85
M16 30 1,22 1,41 1,55 50 199
M20 40 1,22 1,41 1,55 86 454
Design loads - Effective anchorage depth (hef) Pull out failure N kN Shear failure V kN Bending moment M Nm Recommended loads Pull out failure N kN Shear failure V kN Bending moment M Nm 1) Application limited to statically indeterminated systems.
M8 6 9,6 19,2 M8 4,2 6,8 13,7
M10 8 15,2 39,2 M10 5,7 10,8 28
M12 13,3 21,6 68 M12 9,5 15,4 48
M16 20 40 159,2 M16 14,2 28,5 113,5
M20 26,6 61,4 324,2 M20 19 43,8 231
131
through-setting heavy duty anchors
Vorpa VE.CE7 ZF Heavy duty anchor with European Technical Assesment for non cracked concrete
non cracked concrete
heavy duty anchors
products group
VE.CE7 ZF
EAD 330232-00-0601 for non cracked concrete
R30-R120
Approved for • cracked and non-cracked concrete C20/25-C50/60 • anchorage under static, quasi/ static actions M6-M20 • anchorage under fire exposure in standard TR 020 R30-R120
To fix • parapets • gates, stairs, profiles • steel beams • machine tools • industrial systems • heavy duty metal constructions • static, quasi/static anchorages
CALCULATION SOFTWARE
product information Characteristics • special wedge hot dipped galvanized anchor assembled with hex nut and washer with European Technical Assessment for non cracked concrete • ideal corrosion protection • fire tested in compliance with TR020. Fire resistance ratings R30– R120 • reduced hole diameter • suitable for through-setting applications in concrete • thread diameter and hole diameter are the same • reinforced anchor’s head to avoid damaging the thread during the installation
Installation • through-setting anchor Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
installation sequence
Clean the hole before the installation
Examples of applications
132
through-setting heavy duty anchors
Vorpa VE.CE7 ZF Heavy duty anchor with European Technical Assesment for non cracked concrete
non cracked concrete
product code and technical data heavy duty anchors
VE.CE7 ZF hef
Code
*
4604 4605 4601 4610 4607 44624 4609 44628 4611 4471 44627 4613 4615 4616 4618 4619
Description
Lt mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
VE.CE7 ZF 8/4-60 VE.CE7 ZF 8/15-80 VE.CE7 ZF 8/30-95 VE.CE7 ZF 8/45-110 VE.CE7 ZF 10/5-60 VE.CE7 ZF 10/15-90 VE.CE7 ZF 10/45-120 VE.CE7 ZF 10/70-145 VE.CE7 ZF 12/15-110 VE.CE7 ZF 12/30-125 VE.CE7 ZF 12/50-145 VE.CE7 ZF 12/85-180 VE.CE7 ZF 16/10-130 VE.CE7 ZF 16/20-150 VE.CE7 ZF 20/5-150 VE.CE7 ZF 20/35-180
65 80 100 115 60 90 120 145 110 125 145 180 130 150 150 180
8 8 8 8 10 10 10 10 12 12 12 12 16 16 20 20
40 47 47 47 40 56 56 56 67 67 67 67 84 84 99 99
4 15 30 45 5 15 45 70 15 30 50 85 10 20 5 35
15 15 15 15 25 25 25 25 50 50 50 50 100 100 160 160
13 13 13 13 17 17 17 17 19 19 19 19 24 24 30 36
h1 = Min. hole depth Lt = Anchor length do = Hole diameter Tfix = Fixture thickness Tinst = Torque Ch = Spanner hef = Effective anchorage depth
* Not covered by ETA
VE.CE7 ZF Installation data Performance data Effective anchorage depth Reduced anchorage depth Drill hole diameter Drill hole diameter in the fixture Drill hole depth Torque moment Width across nut
M8
M10
M12
M16
M20
hef hef,red do do h1 Tinst SW
mm mm mm mm mm Nm mm
44 - - 351) 8 8 9 9 65 55 15 15 13 13
48 - - 42 10 10 12 12 70 65 30 30 17 17
65 - - 50 12 12 14 14 90 75 50 50 19 19
82 - - 64 16 16 18 18 110 95 100 100 24 24
100 - - 78 20 20 22 22 130 110 200 200 30 30
Spacing and edge distance Effective anchorage depth Characteristic spacing Characteristic edge distance Minimum spacing Minimum edge distance Minimum thickness of concrete slab
hef Scr,N Ccr,N Smin Cmin hmin
mm mm mm mm mm mm
44 351) 132 105 66 52,5 40 40 45 45 100 80
48 42 144 126 72 63 55 55 65 65 100 100
65 50 195 150 97,5 75 75 100 90 100 130 100
82 64 246 192 123 96 90 110 105 100 170 130
100 300 150 105 125 200
2) Characteristic values - Effective anchorage depth (hef) C25/30 Pull out failure N kN Shear failure V kN
M8 18,7 19,3
M10 23,6 28,1
M12 34,5 41,3
M16 51,4 73
M20 70 103,6
Recommended loads (hef) C25/30 Pull out failure Shear failure Bending moment
M8 6,3 6,3 13,1
M10 8,4 8,8 25,7
M12 13,8 14,3 44,6
M16 19,6 23,6 99,9
M20 26,3 37,1 195
N V M
kN kN Nm
1) Application limited to statically indeterminated systems. 2) M12-M16-M20 Test based on EAD 330232-00-0601: pull out failure is not decisive
133
78 234 117 140 140 160
through-setting heavy duty anchors
Vorpa VE.A Steel anchor
non cracked concrete
heavy duty anchors
products group Suitable for • concrete
VE.A
*
VE.A INOX A2
*
VE.A INOX A4
To fix • steel beams • sections • plates • heavy structural works • plants engineering • railings and balustrades • gates
VE.A ZG Geomet
*
VE.A M VE.A M INOX A2 with internl thread
A4 INOX Test report available
316 *
A2 INOX 304
product information Characteristics • through steel anchor composed of steel pin, nut, washer and expansion clip • the version with internal thread VE.A M to be used with bolts of any metrical length • high load values and fast setting • VE.A ZG for outdoor use and damp conditions • reduced hole diameter • suitable for through-setting applications in concrete • thread diameter and hole diameter are the same • reinforced anchor’s head to avoid damaging the thread during the installation
Installation • through-setting anchor Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Examples of applications
134
through-setting heavy duty anchors
Vorpa VE.A Steel anchor
non cracked concrete
installation sequence heavy duty anchors
Clean the hole before the installation
product code and technical data
VE.A hef
Code
1601 1594 1602 1625 1603 1639 1621 1604 51604 1605 1618 1606 51605 51606 51607 51609 51630 51631 51632 1607 51608 1608 5626 1609 1614 1641 1643 1610 1626 5611 1611 1640 1612 1627 1613 1637 1687 5621 5622
Description
Lt mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
VE.A 6/5-50 VE.A 6/7-55 VE.A 6/10-65 VE.A 6/25-80 VE.A 6/40-100 VE.A 6/70-130 VE.A 8/1-50 VE.A 8/5-55 VE.A 8/10-60 VE.A 8/15-75 VE.A 8/25-90 VE.A 8/50-115 VE.A 8/70-130 VE.A 8/100-160 VE.A 8/120-180 VE.A 8/140-200 VE.A 8/180-240 VE.A 8/220-280 VE.A 8/260-320 VE.A 10/5-65 VE.A 10/10-80 VE.A 10/20-90 VE.A 10/30-100 VE.A 10/50-120 VE.A 10/70-140 VE.A 10/100-170 VE.A 10/140-210 VE.A 12/10-75 VE.A 12/15-90 VE.A 12/20-100 VE.A 12/20-110 VE.A 12/30-120 VE.A 12/50-145 VE.A 12/65-160 VE.A 12/85-180 VE.A 12/100-200 VE.A 14/10-100 VE.A 14/15-110 VE.A 14/30-145
50 55 65 80 100 130 50 55 60 75 90 115 130 160 180 200 240 280 320 65 80 90 100 120 140 170 210 75 90 100 110 120 145 160 180 200 100 110 145
6 6 6 6 6 6 8 8 8 8 8 8 8 8 8 8 8 8 8 10 10 10 10 10 10 10 10 12 12 12 12 12 12 12 12 12 14 14 14
35 40 50 50 55 55 40 40 40 55 55 55 55 55 55 55 55 55 55 50 60 60 60 60 60 60 60 55 65 80 80 80 85 85 85 85 85 85 110
6 7 10 25 40 70 1 5 10 15 25 50 70 100 120 140 180 220 260 5 10 20 30 50 70 100 140 10 15 20 20 30 50 65 85 100 10 15 30
10 10 10 10 10 10 20 20 20 20 20 20 20 20 20 20 20 20 20 45 45 45 45 45 45 45 45 65 65 65 65 65 65 65 65 65 85 85 85
10 10 10 10 10 10 13 13 13 13 13 13 13 13 13 13 13 13 13 17 17 17 17 17 17 17 17 19 19 19 19 19 19 19 19 19 22 22 22
135
h1 = Min. hole depth Lt = Anchor length do = Hole diameter Tfix = Fixture thickness Tinst = Torque Ch = Spanner hef = Effective anchorage depth
Follows on the next page
through-setting heavy duty anchors
Vorpa VE.A Steel anchor
non cracked concrete
heavy duty anchors
product code and technical data
VE.A hef
Code
Description
Lt mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
5623 1629 1615 1636 1616 1620 1638 1617 1624 618 1644 619 1628 1619 1642 1690
VE.A 14/60-175 VE.A 16/5-90 VE.A 16/10-110 VE.A 16/20-125 VE.A 16/30-145 VE.A 16/60-175 VE.A 16/90-200 VE.A 16/105-220 VE.A 20/15-145 VE.A 20/30-170 VE.A 20/60-200 VE.A 20/80-220 VE.A 20/130-270 VE.A 24/25-180 VE.A 24/100-260 VE.A 24/180-350
175 90 110 125 145 175 200 220 145 170 200 220 270 180 260 350
14 16 16 16 16 16 16 16 20 20 20 20 20 24 24 24
105 70 85 90 100 100 100 100 110 120 120 120 120 135 135 135
60 5 10 20 30 60 90 105 15 30 60 80 130 25 100 180
85 115 115 115 115 115 115 115 200 200 200 200 200 320 320 320
22 24 24 24 24 24 24 24 30 30 30 30 30 36 36 36
A2 INOX
VE.A INOX A2
Code
2601 2600 2602 2603 52604 2604 2605 2618 2627 2606 52120 2607 2617 2608 2609 2610 2613 5607 5608 2611 2630 2611S 2612 2629 2615 2619 2616 2620
304
Description
Lt mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2
45 55 65 85 50 55 75 90 95 115 200 65 75 90 120 75 80 90 100 110 120 130 145 90 110 125 145 175
6 6 6 6 8 8 8 8 8 8 8 10 10 10 10 12 12 12 12 12 12 12 12 16 16 16 16 16
30 45 50 60 40 40 55 55 55 55 55 50 60 60 60 55 50 80 80 80 80 85 85 70 75 75 100 100
10 5 10 20 1 5 15 25 30 50 140 5 10 20 50 10 20 15 20 25 30 35 50 5 20 35 30 65
10 10 10 10 20 20 20 20 20 20 20 45 45 45 45 65 65 65 65 65 65 65 65 115 115 115 115 115
10 10 10 10 13 13 13 13 13 13 13 17 17 17 17 19 19 19 19 19 19 19 19 24 24 24 24 24
6/10-45 6/5-55 6/10-65 6/20-85 8/1-50 8/5-55 8/15-75 8/25-90 8/30-95 8/50-115 8/140-200 10/5-65 10/10-75 10/20-90 10/50-120 12/10-75 12/20-80 12/15-90 12/20-100 12/25-110 12/30-120 12/35-130 12/50-145 16/5-90 16/20-110 16/35-125 16/30-145 16/65-175
136
h1 = Min. hole depth Lt = Anchor length do = Hole diameter Tfix = Fixture thickness Tinst = Torque Ch = Spanner hef = Effective anchorage depth
through-setting heavy duty anchors
Vorpa VE.A Steel anchor
non cracked concrete
product code and technical data
hef
Art.
2621 2622
Descrizione
Lt mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
VE.A A2 20/20-160 VE.A A2 20/40-180
160 180
20 20
120 120
20 40
200 200
28 28
A4 INOX
VE.A INOX A4
Code
13750 13751 13752 13753 13774 13765 13780 13754 13755 13776 13756 13781 13757 13766 13775 13777 13758 52611 13767 13759 13760 13763 13768 13778 13761 13762 13769
Description
VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4
6/10-55 6/25-85 8/10-65 8/20-75 8/45-105 8/50-115 8/55-120 8/80-130 10/10-65 10/15-75 10/20-90 10/30-100 10/50-120 10/60-130 10/70-140 12/20-80 12/10-100 12/20-110 12/25-120 12/50-145 12/80-180 16/5-100 16/10-110 16/35-125 16/50-145 16/60-175 20/30-175
316
Lt mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
55 85 65 75 105 115 120 130 65 75 90 100 120 130 140 80 100 110 120 145 180 100 110 125 145 175 175
6 6 8 8 8 8 8 8 10 10 10 10 10 10 10 12 12 12 12 12 12 16 16 16 16 16 20
40 55 45 55 55 55 55 45 45 60 60 60 60 60 60 50 80 80 90 80 90 80 85 80 100 100 125
10 25 10 20 45 50 55 80 10 15 20 30 50 60 70 20 10 20 25 50 80 5 10 35 50 60 30
10 10 20 20 20 20 20 20 45 45 45 45 45 45 45 65 65 65 65 65 65 115 115 115 115 115 200
10 10 13 13 13 13 13 13 17 17 17 17 17 17 17 19 19 19 19 19 19 24 24 24 24 24 28
Examples of applications
137
h1 = Min. hole depth Lt = Anchor length do = Hole diameter Tfix = Fixture thickness Tinst = Torque Ch = Spanner hef = Effective anchorage depth
heavy duty anchors
VE.A INOX A2
through-setting heavy duty anchors
Vorpa VE.A Steel anchor
non cracked concrete
heavy duty anchors
product code and technical data
VE.A ZG Geomet hef
Code
54604 54605 54606 54620 54607 54617 54621 54611 54612 54622 54615 54616 54618 54619
Description
VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG
8/3-65 8/10-80 8/30-100 8/50-115 10/5-80 10/15-90 10/45-120 12/20-110 12/50-145 12/90-180 16/10-125 16/35-150 20/30-160 24/20-180
Lt mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
65 80 100 115 80 90 120 110 145 180 125 150 160 180
8 8 8 8 10 10 10 12 12 12 16 16 20 24
40 55 55 55 50 60 60 80 80 80 85 100 120 135
3 10 30 50 5 15 45 20 50 90 10 35 30 20
20 20 20 20 40 40 40 50 50 50 125 125 250 320
13 13 13 13 17 17 17 19 19 19 24 24 30 36
h1 = Min. hole depth Lt = Anchor length do = Hole diameter Tfix = Fixture thickness Tinst = Torque Ch = Spanner hef = Effective anchorage depth
Examples of applications
VE.A Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness Through hole in the object to be fixed
Scr Ccr Smin Cmin hmin
Permissible loads - applications in concrete C20/25 VE.A
mm mm mm mm mm mm
VE.A M6 180 70 90 35 100 7
VE.A M8 190 80 95 40 100 9
daN 245 420
VE.A M10 VE.A M12 220 300 100 120 110 150 50 60 100 150 12 14
520
770
VE.A M14 VE.A M16 VE.A M20 VE.A M24 340 380 440 520 150 170 240 240 170 190 220 290 75 85 105 115 180 180 210 240 16 18 22 26
850
• Always respect the installation parameters • In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load • The table shows the permissible loads for tension, shear and combined tension and shear loads 138
950
1390
1 daN ≃1 kg 1850
through-setting heavy duty anchors
Vorpa VE.A Steel anchor
non cracked concrete
product code and technical data
* VE.A M INOX A2 with internal thread
Code.
13770 13771 13772 13773 13770 A2 13771 A2 13772 A2 13773 A2
Description
* A2 INOX 304
Lt mm
M mm
do mm
h1 mm
Tinst Nm
VE.A M VE.A M VE.A M VE.A M
8/50 10/50 12/60 16/75
50 50 60 75
M6 M8 M10 M12
8 10 12 16
55 55 65 80
10 20 45 65
VE.A A2 M VE.A A2 M VE.A A2 M VE.A A2 M
8/50 10/50 12/60 16/75
50 50 60 75
M6 M8 M10 M12
8 10 12 16
55 55 65 80
10 20 45 65
heavy duty anchors
VE.A M with internal thread
h1
M
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length do = Hole diameter tinst = Torque M = Internal thread
Examples of applications
VE.A M Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness Through hole in the object to be fixed Permissible loads - applications in concrete C20/25 VE.A M
Scr Ccr Smin Cmin hmin
mm mm mm mm mm mm
VE.A M M6/Ø8 180 70 90 35 100 7
VE.A M M8/Ø10 190 80 95 40 100 9
VE.A M M10/Ø12 220 100 110 50 100 12
VE.A M M12/Ø16 300 120 150 60 150 14
daN
220
340
480
620
• Always respect the installation parameters • In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load • The table shows the permissible loads for tension, shear and combined tension and shear loads 139
1 daN≃1 kg
through-setting heavy duty anchors
Vorpa VE Steel anchor
non cracked concrete
heavy duty anchors
products group
VE
Suitable for • concrete
Test report available
To fix • steel beams • machineries • sections • plates • heavy structural works • plants engineering • railings and balustrades • gates, stairs • profiles
product information Characteristics • through steel anchor composed of steel pin, nut, washer and two stailess steel expansion clip • reduced hole diameter • suitable for through-setting applications in concrete • thread diameter and hole diameter are the same • reinforced anchor’s head to avoid damaging the thread during the installation • minimum slippage due to powerfull expansion when tightening • fast setting also thanks to pre-mounted nut and washer
Installation • through-setting anchor Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
installation sequence
Clean the hole before the installation
Examples of applications
140
through-setting heavy duty anchors
Vorpa VE Steel anchor
non cracked concrete
product code and technical data heavy duty anchors
VE
Code
601 602 603 604 605 599 606 607 608 609 610 611 612 613 614 615 600 616 589 617
Description
Lt mm
L. Thread mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
VE 6/5-45 VE 6/15-65 VE 6/40-100 VE 8/5-55 VE 8/10-75 VE 8/25-90 VE 8/50-115 VE 10/10-65 VE 10/20-90 VE 10/40-120 VE 12/5-75 VE 12/15-110 VE 12/25-145 VE 12/80-180 VE 14/15-110 VE 14/25-145 VE 16/10-110 VE 16/25-145 VE 16/55-175 VE 16/100-220
45 65 100 55 75 90 115 65 90 120 75 110 145 180 110 145 110 145 175 220
19 39 74 20 40 55 75 26 42 71 27 45 90 90 45 75 46 78 81 96
6 6 6 8 8 8 8 10 10 10 12 12 12 12 14 14 16 16 16 16
35 45 55 40 60 55 55 45 60 70 60 85 110 90 85 110 85 105 105 105
5 15 40 5 10 25 50 10 20 40 5 15 25 80 15 25 10 25 55 100
10 10 10 20 20 20 20 45 45 45 65 65 65 65 85 85 115 115 115 115
10 10 10 13 13 13 13 17 17 17 19 19 19 19 22 22 24 24 24 24
hef
h1 = Min. hole depth Lt = Anchor length do = Hole diameter Tfix = Fixture thickness Tinst = Torque Ch = Spanner hef = Effective anchorage depth
Examples of applications
VE Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness
Scr Ccr Smin Cmin hmin
Permissible loads - applications in concrete C20/25 VE
mm mm mm mm mm
VE M6 180 70 90 35 100
VE M8 190 80 95 40 100
VE M10 220 100 110 50 100
VE M12 300 120 150 60 150
VE M14 340 150 170 75 180
VE M16 380 170 190 85 180
daN
250
380
520
800
850
1400
• Always respect the installation parameters • In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load • The table shows the permissible loads for tension, shear and combined tension and shear loads 141
VE M20 440 240 220 105 210 1 daN≃1 kg 1750
through-setting heavy duty anchors
Vorpa VSX Steel anchor
concrete
heavy duty anchors
products group
VSX
Suitable for • concrete
To fix • parapets • steel beams • machine tools • industrial systems • heavy duty metal constructions • industrial signals
product information Characteristics • high performances through steel anchor with central bush and antirotation system • reduced hole diameter granting a better capacity • smooth expansion thanks to the three cuts on the expansion body • the red collar prevents the anchor turning in the hole on installation
Installation • through-setting anchor Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
installation sequence
Clean the hole before the installation
Examples of applications
142
through-setting heavy duty anchors
Vorpa VSX Steel anchor
concrete
product code and technical data heavy duty anchors
VSX
Code
959 958 960 961 962 963 964 965 967 966
Description
Lt mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
VSX 8/15-70 VSX 8/30-85 VSX 10/15-85 VSX 10/50-120 VSX 12/15-100 VSX 12/50-135 VSX 14/20-115 VSX 14/50-145 VSX 16/20-130 VSX 16/40-150
70 85 85 120 100 135 115 145 130 150
8 8 10 10 12 12 14 14 16 16
55 55 65 65 75 75 85 85 95 95
15 30 15 50 15 50 20 50 20 40
6 6 10 10 25 25 50 50 85 85
13 13 17 17 19 19 22 22 24 24
h1 = Min. hole depth Lt = Anchor length do = Hole diameter Tfix = Fixture thickness Tinst = Torque Ch = Spanner
Examples of applications
VSX Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness
Scr Ccr Smin Cmin hmin
Permissible loads - applications in concrete C20/25 VSX
mm mm mm mm mm
VSX 8/M5 180 90 90 50 150
VSX 10/M6 220 110 130 70 150
VSX 12/M8 280 140 170 90 200
VSX 10/M10 400 170 230 110 200
daN
250
350
470
600
• Always respect the installation parameters • In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load • The table shows the permissible loads for tension, shear and combined tension and shear loads 143
VSX 16/M12 450 200 270 140 250 1 daN≃1 kg 700
through-setting heavy duty anchors
Vorpa VSA - Seismic category C1 Heavy duty safety anchor with European Technical Assesment for cracked concrete and seismic zone
cracked concrete
products group Approved for • cracked and non-cracked concrete C20/25-C50/60 • anchorage under static, quasi/ static actions M8-M12 • seismic applications C1 TR045 M8 - M12 • anchorage under fire exposure in standard TR 020 R30-R120
heavy duty anchors
VSA V with 8.8 hexagonal head screw
VSA B with stud and nut
To fix • parapets • steel beams • machine tools • industrial systems • heavy duty metal constructions • static, quasi/static anchorages • structural fixings
VSA S with 10.9 flat countersunk head screw
FIXING IN SEISMIC
C1 EAD 330232-00-0601 for cracked and uncracked concrete and seismic zone. Seismic Category C1
R30-R120
CALCULATION SOFTWARE
product information Characteristics • high performances through steel anchor with central bush and antirotation system with European Tecnhical Assesment for cracked and non-cracked concrete • approved use under seismic loading, performance category C1 • smooth expansion thanks to the three cuts on the expansion body • high tensile loads with standard depth • high shear resistances, applications are possible with minimum centre to centre and edge distance • the red ring collar prevents the anchor turning in the hole on installation • regular grip on the base material thanks to the expansion shell
Installation • through-setting anchor Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Examples of applications
144
through-setting heavy duty anchors
Vorpa VSA - Seismic category C1 Heavy duty safety anchor with European Technical Assesment for cracked concrete and seismic zone
cracked concrete
installation sequence heavy duty anchors
Clean the hole before the installation
product code and technical data VSA V with 8.8 hexagonal head screw
Code
Description
10880 VSA V 12/10-80 10881 VSA V 12/20-90 10882 VSA V 12/50-120 10883 VSA V 15/10-90 10884 VSA V 15/20-100 10885 VSA V 15/50-130 10886 VSA V 18/10-110 10887 VSA V 18/25-125 10888 VSA V 18/50-150 10889 VSA V 18/100-200 10890 * VSA V 24/25-140 10891 * VSA V 24/50-165
Lt mm
80 90 120 90 100 130 110 125 150 200 140 165
Screw d x Lv mm
M8x80 M8x90 M8x120 M10x90 M10x100 M10x130 M12x120 M12x130 M12x160 M12x200 M16x 140 M16x 170
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
12 12 12 15 15 15 18 18 18 18 24 24
85 85 85 95 95 95 120 120 120 120 130 130
10 20 50 10 20 50 10 25 50 100 25 50
25 25 25 50 50 50 80 80 80 80 150 150
13 13 13 17 17 17 19 19 19 19 24 24
h1 = Min. hole depth Lt = Anchor length Lv = Screw length do = Hole diameter d = Screw diameter tfix = Fixture thickness Tinst = Torque Ch = Spanner
VSA B with stud and nut
Code
10900 10901 10902 10903 10904 10905 10906 10907 10908 10909 10910 * 10911 *
Description
Lt mm
Stud d x Lb mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch mm
VSA B 12/10-80 VSA B 12/20-90 VSA B 12/50-120 VSA B 15/10-90 VSA B 15/20-100 VSA B 15/50-130 VSA B 18/10-110 VSA B 18/25-125 VSA B 18/50-150 VSA B 18/100-200 VSA B 24/25-140 VSA B 24/50-165
80 90 120 90 100 130 110 125 150 200 140 165
M8x92 M8x102 M8x132 M10x105 M10x115 M10x145 M12x135 M12x150 M12x180 M12x220 M16x165 M16x190
12 12 12 15 15 15 18 18 18 18 24 24
85 85 85 95 95 95 120 120 120 120 130 130
10 20 50 10 20 50 10 25 50 100 25 50
25 25 25 50 50 50 80 80 80 80 150 150
13 13 13 17 17 17 19 19 19 19 24 24
* Not included in C1 fixing in seismic
VSA V - VSA B Anchor diameter Anchor length Effective anchorage depth Fixture thickness Drill hole diameter Drill hole depth Drill hole diameter in the fixture Torque moment
d L hef Tfix do h1 df Tinst
mm mm mm mm mm mm mm Nm
VSA V - VSA B M8 12 80-90-110 59 10-20-50 12 85 14 25
145
VSA V - VSA B M10 15 90-100-130 67 10-20-50 15 95 17 50
VSA V - VSA B M12 18 110-125-150-200 88 10-25-50-100 18 120 20 80
VSA V - VSA B M16 24 140-165 99 25-50 24 130 26 150
through-setting heavy duty anchors
Vorpa VSA - Seismic category C1 Heavy duty safety anchor with European Technical Assesment for cracked concrete and seismic zone
cracked concrete
heavy duty anchors
product code and technical data VSA S with 10.9 flat countersunk head screw Code
10920 10921 10922 10923 10924 10925 10926 10927 10928
Description
Lt mm
Screw d x Lv mm
do mm
h1 mm
Tfix max mm
Tinst Nm
Ch mm
VSA S VSA S VSA S VSA S VSA S VSA S VSA S VSA S VSA S
85 95 125 95 105 135 120 135 160
M8x80 M8x90 M8x130 M10x100 M10x110 M10x140 M12x120 M12x140 M12x170
12 12 15 15 15 15 18 18 18
85 85 95 95 95 95 120 120 120
16 26 56 15 25 55 18 33 58
25 25 50 50 50 50 80 80 80
5 5 5 6 6 6 8 8 8
12/16-85 12/26-95 12/56-125 15/15-95 15/25-105 15/55-135 18/18-120 18/33-135 18/58-160
h1 = Min. hole depth Lt = Anchor length Lv = Screw length do = Hole diameter d = Screw diameter tfix = Fixture thickness Tinst = Torque Ch = Spanner
Examples of applications
VSA S Anchor diameter Anchor length Effective anchorage depth Fixture thickness Drill hole diameter Drill hole depth Drill hole diameter in the fixture Torque moment
d L hef Tfix do h1 df Tinst
VSA S M8 12 86-96-126 59 16-26-56 12 85 14 25
mm mm mm mm mm mm mm Nm
146
VSA S M10 15 95-105-135 67 15-25-55 15 95 17 50
VSA S M12 18 120-135-160 88 18-33-58 18 120 20 80
through-setting heavy duty anchors
Vorpa VSA - Seismic category C1 Heavy duty safety anchor with European Technical Assesment for cracked concrete and seismic zone
cracked concrete
technical data
VSA Ø12
VSA Ø15
VSA Ø18
VSA Ø24
Scr,N Ccr,N Smin Cmin hmin
250 200 120 80 125
290 220 140 90 13
390 260 180 110 190
420 280 240 130 220
Pull out failure Non-cracked concrete Cracked concrete C30/37 C40/50 C50/60
Nrk,P C20/25 Nrk,P C20/25 Ψ 30/37 Ψ 40/50 Ψ 50/60
12 7 1,22 1,41 1,55
16 10 1,22 1,41 1,55
25 18 1,22 1,41 1,55
40 28 1,22 1,41 1,55
Shear failure Bending moment
VRk,S MRK,S
16,8 30
25 60
33,7 105
62,8 266
Nrk,P Nrk,P Vrk Mrk
10 5,8 13,4 24
13,3 8,3 20 48
20,8 15 26,9 84
33,3 23,3 50,2 212,8
N N V M
7,1 4,1 9,5 17,1
9,5 5,9 14,2 34,2
14,8 10,7 19,2 60
23,7 16,6 35,8 152
Nrk,P,seis Vrk,seis
5,6 13,4
10 25
14,4 33,7
Nrk,P,seis Vrk,seis
3,1 10,7
5,5 20
8 26,9
Installation data Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum thickness member Characteristic values
Design loads Pull out failure Non-cracked concrete Cracked concrete Shear failure Bending moment Recommended loads Pull out failure Non-cracked concrete Cracked concrete Shear failure Bending moment
Characteristic values for seismic category C1 Pull out failure Shear failure Design loads for seismic category C1 Pull out failure Shear failure
Examples of applications
147
heavy duty anchors
VSA-seismic category C1
through-setting heavy duty anchors
Vorpa VSA S A4 - Seismic category C1+C2 Heavy duty safety anchor with European Technical Assesment for cracked concrete and seismic zone
cracked concrete
products group heavy duty anchors
VSA S A4+SEISMIC Approved for with A4 stainless steel • cracked and non-cracked flat countersunk head concrete M8-M12 screw
• anchorage under static, quasi/ static actions M8-M12 • seismic applications C1-C2 TR045 - M8-M12 • anchorage under fire exposure in standard TR 020 R30-R120
FIXING IN SEISMIC
C1+C2 EAD 330232-00-0601 for cracked and uncracked concrete and seismic zone. Seismic Category C1-C2
A4 INOX R30-R120
316
To fix • parapets • steel beams • machine tools • industrial systems • heavy duty metal constructions • static, quasi/static anchorages • structural fixings
CALCULATION SOFTWARE
product information Characteristics • special wedge anchor with central bush with European Technical Assesment for cracked concrete and performance category C1-C2 under seismic action • approved for use in cracked and non-cracked concrete • suitable for surface, through, and stand-of fastening • fire tested in compliance with DIN 4102-2. Fire resistance ratings R30–R120
Installation • through-setting anchor Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
installation sequence
Clean the hole before the installation
Examples of applications
148
through-setting heavy duty anchors
Vorpa VSA S A4 - Seismic category C1+C2 Heavy duty safety anchor with European Technical Assesment for cracked concrete and seismic zone
cracked concrete
product code and technical data
Code
10401 10402 10403 10405 10406 10407
Description
VSA S+SM A4 VSA S+SM A4 VSA S+SM A4 VSA S+SM A4 VSA S+SM A4 VSA S+SM A4
12/25-95 12/50-120 15/15-100 15/35-120 15/50-135 18/40-135
heavy duty anchors
VSA S A4+SEISMIC with A4 stainless steel flat countersunk head screw
A4 INOX 316
Lt mm
Screw d x Lv mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch mm
95 120 100 120 135 135
M8x95 M8x120 M10x100 M10x120 M10x135 M12x135
12 12 15 15 15 18
80 80 95 95 95 105
25 50 15 35 50 40
17,5 17,5 42,5 42,5 42,5 50
5 5 6 6 6 8 h1 = Min. hole depth Lt = Anchor length Lv = Screw length do = Hole diameter d = Screw diameter tfix = Fixture thickness Tinst = Torque Ch = Spanner
Other sizes on request
VSA S inox A4+SEISMIC Installation data Nominal drill hole diameter Torque moment Setting depth Minimum thickness of concrete member Drill hole depth Hole in the fixture
VSA S M8 VSA S M10 VSA S M12 do Tinst hnom hmin h1 df
[mm] [Nm] [mm] [mm] [mm] [mm]
12 17,5 70 120 80 14
15 42,5 85 140 95 17
18 50 95 160 105 20
Design method according to EAD 330232-00-0601 VSA S M8 Steel failure Characteristic resistance Tension Partial safety factor Shear Partial safety factor Bending moment Partial safety factor Tension loads C1 Tension loads C2 Partial safety factor Shear loads C1 Shear loads C2 Partial safety factor Pull-out failure Characteristics resistance non cracked concrete C20/25 Characteristics resistance cracked concrete C20/25 Characteristics resistance seismic performance C1 Characteristics resistance seismic performance C2 C30/37 Increasing factor C40/50 C50/60
NRk,s YMs VRk,s YMs M0Rk,s YMs NRk,s, C1 NRk,s, C2 YMs, seis VRk, seis, C1 VRk, seis, C2 YMs, seis
[kN] [kN] [Nm] [kN] [kN] [kN] [kN]
NRk,p,ucr NRk,p,cr NRk,seis,C1 NRk,seis,C2
[kN] [kN] [kN] [kN]
ψc
[-]
1) Pull out it not decisive
149
VSA S M10 VSA S M12
26 1,87 24 1,36 26 1,25 26 26 1,87 11,5 10,8 1,36
41 1,87 37 1,36 52 1,25 41 41 1,87 23,3 17,4 1,36
60 1,87 62 1,36 92 1,25 60 60 1,87 31,6 15,4 1,36
16 9 9 4,8
25 16 16 16,5 1,22 1,41 1,58
35 1) 26 24,8
( fck 20 )
0,5
through-setting heavy duty anchors
Vorpa VSP C Steel anchor
concrete
heavy duty anchors
products group
VSP C with 8.8 hexagonal head screw
Suitable for • concrete • pre-stressed concrete ceiling slabs
To fix • light metal structural work • brackets and rails for industrial systems such as lighting, heating, ventilation • timber constructions • sprinkler systems
product information Characteristics • special short body steel anchor with anti-rotation design and expansion conical nut • the collar prevents slippage of the anchor into the hole and facilitates the installation since it is not necessary to respect the depth of drilling • the optimized geometry reduces the energy required for fixing and allows its use even in narrowed spaces
Installation • pre-setting anchor Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
installation sequence
Clean the hole before the installation
Examples of applications
150
through-setting heavy duty anchors
Vorpa VSP C Steel anchor
concrete
product code and technical data heavy duty anchors
VSP C with 8.8 hexagonal head screw
Code
Description
Lt mm
3813 3814
VSP C 15/70 - M10 VSP C 18/80 - M12
70 80
Screw d x Lv mm
M10x70 M12x80
do mm
h1 mm
tfix max mm
df mm
Tinst Nm
Ch
15 18
≥65 ≥75
8 10
18 22
50 65
17 19
h1 = Min. hole depth Lt = Anchor length Lv = Screw length do = Hole diameter d = Screw diameter df = Hole diameter in the fixture tfix = Fixture thickness tinst = Torque Ch = Spanner
VSP C Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness
Scr Ccr Smin Cmin hmin
VSP C M10 290 145 180 90 130
mm mm mm mm mm
VSP C M12 300 150 200 100 130
Permissible loads - applications in concrete C20/25 VSP C
1 daN≃1 kg
daN
300
• Always respect the installation parameters • In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load • The table shows the permissible loads for tension, shear and combined tension and shear loads 151
500
through-setting heavy duty anchors
Vorpa CSB COMBI Steel anchor with European Technical Assesment for cracked concrete
cracked concrete
products group heavy duty anchors
CSB COMBI thread M8/M10
Approvato per • cracked and non cracked concrete • multiple use for non structural applications for cracked and non cracked concrete and prestressed hollow core slabs
Per ancorare • industrial systems • structural fixings • profiles • pipes • plants engineering • structural fixings
Idoneo anche per • natural stone • solid brick EAD 330232-00-0601 for cracked and non cracked concrete
R30-R120
ETAG 001-046 for multiple use for non structural applications for cracked and non cracked concrete and pre-stressed hollow core slabs
product information Characteristics • steel screw with European Technical Assesment for cracked concrete and multiple use for non structural applications for pre-stressed hollow core slabs. • reduced hole diameter • vibrations resistance • ideal for permanent and removable fixing both inside and outside • virtually expansion-free operation allows cost-efficient fixing with small axial spacing and edge distances. • fire resistance ratings R30–R120
Installation • through-setting anchor Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
installation sequence
Clean the hole before the installation
product code and technical data Code Description
91151 CSB CE COMBI 6x35 91152 CSB CE COMBI 6x55
h1 = Minimum depth of drill hole Lv = Screw length do = Drill hole diameter dv = Screw diameter df = Diameter of clearance hole in the fixture tfix = Maximum thickness of fixture
tfix mm
do mm
Tinst Nm
Ch
Cmin mm
Smin mm
20
6 6
10 10
13 13
40 40
40 40
Tinst = Required torque moment Ch = Spanner hmin = Minimum thickness of concrete member hnom = Overall anchor embedment depth hef = Effective anchorage depth Cmin = Minimum allowable edge distance Smin = Minimum allowable spacing
152
hmin
LV
through-setting heavy duty anchors
Vorpa CSB COMBI Steel anchor with European Technical Assesment for cracked concrete
cracked concrete
installation data CSB COMBI 6x35
CSB COMBI 6x55
Installation data Embedment depth Fixture thickness Hole diameter Hole depth Torque moment Hole diameter in the fixture
hnom Tfix do h1 Tinst df
mm mm mm mm Nm mm
*35 0 6 40 ≤10 8
*35 20 6 40 ≤10 8
Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness
Scr,N Ccr,N Smin Cmin hmin
mm mm mm mm mm
81 40,5 35 35 80
81 93 40,5 46,5 35 40 35 40 80 100
132 66 40 40 100
Characteristic values application in concrete non-cracked C20/C25 hnom mm Embedment depth Nrk,P C20/25 KN Pull out failuree KN ψc C30 KN ψc C40 KN ψc C50
*35 3,0 1,22 1,41 1,58
*35 40 3 ,0 4,0 1,22 1,22 1,41 1,41 1,58 1,58
55 9,0 1,22 1,41 1,58
Characteristic values application in concrete cracked C20/C25 hnom mm Embedment depth KN Nrk,P C20/25 Pull out failure KN ψc C30 KN ψc C40 KN ψc C50
*35 3,0 1,22 1,41 1,58
*35 40 3 ,0 2,0 1,22 1,22 1,41 1,41 1,58 1,58
55 4,0 1,22 1,41 1,58
Shear failure Bending moment Values with reduction factor Pull out failure non cracked concrete Pull out failure cracked concrete Shear failure Bending moment Recommended loads Pull out failure non cracked concrete Pull out failure cracked concrete Shear failure Bending moment
40 15 6 45 ≤10 8
55 0 6 60 ≤10 8
VRk,S C20/25 MRK,S
KN KN
7,0 10,9
7,0 7,0 10,9 10,9
7,0 10,9
Nrk,P
KN
2,0
2,0 2,6
6,0
Nrk,P
KN
2,0
2 ,0
2,6
VRk,S MRK,S
KN KN
5,6 8,7
5,6 5,6 8,7 8,7
5,6 8,7
Nrk,P
KN
1,40
1,40 1,80
4,2
Nrk,P
KN
1,40
1,40 0,9
1,80
VRk,S MRK,S
KN KN
4,0 6,2
4,0 4,0 6,2 6,2
4,0 6,2
* hnom=35mm: Only for multiple use in non structural application. See ETA
Examples of applications
153
1,3
heavy duty anchors
CSB COMBI
through-setting heavy duty anchors
Vorpa CSB CE - Seismic category C1+C2 Heavy duty safety anchor with European Technical Assesment for cracked concrete and seismic zone
cracked concrete
products group ETA version approved for • cracked and non-cracked * concrete Ø8 - Ø16 • seismic applications C1-C2 TR045 - Ø12 - Ø16 • seismic applications C1 TR045 CSB Ø10 with mushroom head Torx recess • anchorage under fire exposure in standard TR 020 R30-R120
heavy duty anchors
CSB CE [*] CSB INOX A4 with hexagonal head
CSB E CE [*] with hexagonal stud and nut
All versions suitable for • non-cracked concrete • natural stone
To fix • parapets • steel beams • machine tools • industrial systems • heavy duty metal constructions • structural fixings • profiles • pipes • plants engineering • railings • gates • window and door frames
CSB S CE [*] with countersunk head Torx recess
[*]
FIXING IN SEISMIC
C1+C2 EAD 330232-00-0601 for cracked and uncracked concrete and seismic zone. Seismic Category C1-C2
A4 INOX R30-R120
316
*
CALCULATION SOFTWARE
product information Characteristics • steel screw fixing with special dual lead thread design with European Technical Assesment for cracked concrete and performance category C1-C2 under seismic action • reduced hole diameter • vibrations resistance, easy to identify by the screw’s head • ideal for permanent and removable fixing both inside and outside • virtually expansion-free operation allows cost-efficient fixing with small axial spacing and edge distances. • fire tested in compliance with DIN 4102-2. Fire resistance ratings R30–R120
Installation • through-setting anchor Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Examples of applications
154
through-setting heavy duty anchors
Vorpa CSB CE - Seismic category C1+C2 Heavy duty safety anchor with European Technical Assesment for cracked concrete and seismic zone
cracked concrete
installation sequence heavy duty anchors
Clean the hole before the installation
product code and technical data hmin
CSB CE [*] with hexagonal head
Code Description
93672 93673 93674 93676 93677 93678 93679 93680 93681 93682 93683 93684 93685 93686 93687 93688 93689 93690 93691
CSB CE 8x80 CSB CE 8x100 CSB CE 8x120 CSB CE+SM C1 10x80 CSB CE+SM C1 10x100 CSB CE+SM C1 10x120 CSB CE+SM C1 10x140 CSB CE+SM C1 10x160 CSB CE+SM C2 12x90 CSB CE+SM C2 12x110 CSB CE+SM C2 12x130 CSB CE+SM C2 12x150 CSB CE+SM C2 12x190 CSB CE+SM C2 12x210 CSB CE+SM C2 12x250 CSB CE+SM C2 12x290 CSB CE+SM C2 16x130 CSB CE+SM C2 16x150 CSB CE+SM C2 16x180
dv x Lv mm
tfix mm
do mm
h1 hmin hnom hef Tinst mm mm mm mm Nm
Ch
8 x 80 8 x 100 8 x 120 10 x 80 10 x 100 10 x 120 10 x 140 10 x 160 12 x 90 12 x 110 12 x 130 12 x 150 12 x 190 12 x 210 12 x 250 12 x 290 16 x 130 16 x 150 16 x 180
20 40 60 10 30 50 70 90 10 30 50 70 110 130 170 210 20 40 70
6 6 6 8 8 8 8 8 10 10 10 10 10 10 10 10 14 14 14
75 75 75 85 85 85 85 85 100 100 100 100 100 100 100 100 140 140 140
10 10 10 13 13 13 13 13 15 15 15 15 15 15 15 15 21 21 21
100 100 100 110 110 110 110 110 130 130 130 130 130 130 130 130 170 170 170
60 60 60 70 70 70 70 70 80 80 80 80 80 80 80 80 110 110 110
48 48 48 56 56 56 56 56 64 64 64 64 64 64 64 64 85 85 85
20 20 20 50 50 50 50 50 80 80 80 80 80 80 80 80 160 160 160
Cmin Smin mm mm
45 45 45 50 50 50 50 50 60 60 60 60 60 60 60 60 80 80 80
45 45 45 50 50 50 50 50 60 60 60 60 60 60 60 60 80 80 80
LV
h1 = Minimum depth of drill hole Lv = Screw length do = Drill hole diameter dv = Screw diameter df = Diameter of clearance hole in the fixture tfix = Maximum thickness of fixture tinst = Required torque moment Ch = Spanner hmin = Minimum thickness of concrete member hnom = Overall anchor embedment depth hef = Effective anchorage depth T = 6 lobe recess Cmin = Minimum allowable edge distance Smin = Minimum allowable spacing
[*]
EAD 330232-00-0601 for cracked and uncracked concrete and seismic zone. Seismic Category C1-C2
Examples of applications
155
through-setting heavy duty anchors
Vorpa CSB CE - Seismic category C1+C2 Heavy duty safety anchor with European Technical Assesment for cracked concrete and seismic zone
cracked concrete
heavy duty anchors
product code and technical data
CSB CE INOX A4 with hexagonal head
A4 INOX 316
Code Description
dv x Lv mm
tfix mm
do mm
h1 mm
hmin hnom hef mm mm mm
4340 4341 4342 4343 4350 4351 4352 4353 4354 4360 4361 4362 4363
6x30 6x40 6x60 6x80 8x40 8x50 8x65 8x80 8x100 10x60 10x80 10x100 10x140
4 5 5 25 5 15 5 20 40 15 10 30 70
5 5 5 5 6 6 6 6 6 8 8 8 8
35 50 70 70 40 40 70 70 70 75 90 90 90
80 80 90 90 80 80 100 100 100 90 90 90
CSB A4 6x30 CSB A4 6x40 CSB A4 6x60 CSB A4 6x80 CSB A4 8x40 CSB A4 8x50 CSB A4 8x65 CSB A4 8x80 CSB A4 8x100 CSB A4 10x60 CSB A4 10x80 CSB A4 10x100 CSB A4 10x140
26 35 55 55 35 35 60 60 60 55 70 70 70
df Tinst mm Nm
20 27 45 45 27 27 48 48 48 44 44 44
7 7 7 7 7 7 7 7 7 * * * *
10 10 10 10 20 20 20 20 20 13 13 13 13
SW Cmin Smin Ccr mm mm mm
8 8 8 8 10 10 10 10 10 40 50 50 50
35 35 35 35 40 40 50 50 50 40 40 40
35 35 35 35 40 40 50 50 50 40 40 40
20 40 68 68 40 40 75 75 75 55 85 85 85
Scr mm
Characteristic loads (kN) Estrazione Taglio
40 80 135 135 80 80 150 150 150 110 170 170 170
2,0 3,0 9,0 9,0 4,23 4,23 12,5 12,5 12,5 14,0 23,0 23,0 23,0
4,50 6,50 6,50 6,50 7,10 7,10 9,75 9,75 9,75 15,03 17,50 17,50 17,50
CSB E CE [*] with hexagonal stud and nut hmin
Code Description
93710 93711 93713 93725 93726 93727 93728
CSB E CE 8x90 CSB E CE 8x120 CSB E CE+SM C1 10x105 CSB E CE+SM C1 10x125 CSB E CE+SM C1 10x195 CSB E CE+SM C2 12x118 CSB E CE+SM C2 12x138
dv x Lv mm
tfix mm
do h1 hmin hnom hef Tinst mm mm mm mm mm Nm
Ch
8 x 90 8 x 120 10 x 105 10 x 125 10 x 195 12 x 118 12 x 138
10 40 10 30 100 10 30
6 6 8 8 8 10 10
5 5 7 7 7 8 8
75 75 90 90 90 100 100
100 100 110 110 110 130 130
60 60 70 70 70 80 80
48 48 56 56 56 64 64
20 20 50 50 50 80 80
Cmin Smin mm mm
45 45 50 50 50 60 60
45 45 50 50 50 60 60
LV
CSB S CE [*] with countersunk head Torx recess hmin
Code Description
93700 93701 93702 93703 93704 93705 93706 93707
CSB S CE CSB S CE CSB S CE CSB S CE+SM C1 CSB S CE+SM C1 CSB S CE+SM C1 CSB S CE+SM C2 CSB S CE+SM C2 [*]
EAD 330232-00-0601 for cracked and uncracked concrete and seismic zone. Seismic Category C1-C2
8x70 8x100 8x140 10x80 10x100 10x160 12x100 12x120
dv x Lv mm
tfix mm
do h1 hmin hnom hef Tinst mm mm mm mm mm Nm
Ch
8 x 70 8 x 100 8 x 140 10 x 80 10 x 100 10 x 160 12 x 100 12 x 120
10 40 80 10 30 90 20 40
6 6 6 8 8 8 10 10
T30 T30 T30 T40 T40 T40 T50 T50
75 75 75 90 90 90 100 100
100 100 100 110 110 110 130 130
60 60 60 70 70 70 80 80
48 48 48 56 56 56 64 64
20 20 20 50 50 50 80 80
Cmin Smin mm mm
45 45 45 50 50 50 60 60
45 45 45 50 50 50 60 60
h1 = Minimum depth of drill hole Lv = Screw length do = Drill hole diameter dv = Screw diameter df = Diameter of clearancehole in the fixture tfix = Maximum thickness of fixture tinst = Required torque moment Ch = Spanner hmin = Minimum thicknessof concrete member
156
Ch
LV
hnom = Overall anchor embedment depth hef = Effective anchorage depth T = 6 lobe recess Cmin = Minimum allowable edge distance Smin = Minimum allowable spacing
through-setting heavy duty anchors
Vorpa CSB CE - Seismic category C1+C2 Heavy duty safety anchor with European Technical Assesment for cracked concrete and seismic zone
cracked concrete
technical data ETA versions
Characteristic values Pull out Pull out Pull out Pull out Ψc C30/37 Ψc C40/50 Ψc C50/60 Shear failure Shear failure Shear failure Bending moment
NRKP NRKP
NRKP, p, eq NRKP, p, eq
VRKS VRKS, s, eq VRKS, s, eq MRKS
Values with reduction factor (design loads) Pull out NRKP Pull out NRKP Pull out NRKP, p, eq Pull out NRKP, p, eq Shear failure VRKS Bending moment MRKS Recommended loads Pull out Pull out Pull out Pull out Shear failure Bending moment
N N N N V M
C20/25 (non cracked) C20/25 (cracked) Category C1 Category C2
[kN] [kN] [kN] [kN]
CSB Ø8
CSB Ø10
CSB Ø12
CSB Ø16
16 4 -
20 7,5 6 -
25 9 6,3 2,7
40 16 16 7,2
32,4 19,1 17,7 83
56,9 39,8 39,8 216
1,22 1,41 1,55
[kN] [kN] [kN] [kN]
9,4 19
20,1 12,1 44
C20/25 (non cracked) C20/25 (cracked) Category C1 Category C2
[kN] [kN] [kN] [kN] [kN] [kN]
11,4 2,8 6,2 12,6
16,6 6,2 5 13,4 29,3
17,8 6,4 4,5 1,9 21,6 55,3
28,5 11,4 11,4 5,1 37,9 144
(non cracked) (cracked) Category C1 Category C2
[kN] [kN] [kN] [kN] [kN] [kN]
8,1 2 4,4 9
11,8 4,4 3,5 9,5 20
12,7 4,5 3,2 1,3 15,4 39,5
20,3 8,1 8,1 3,6 27 102
Category C1 Category C2
product code and technical data CSB B with mushroom head Torx recess
Code
3381 3383 4379 93735 93736 93738 93739
Description
CSB B 8x60 CSB B 8x80 CSB B 8x100 CSB B 10x60 CSB B 10x80 CSB B 10x100 CSB B 10x120
dv x Lv mm
tfix mm
do mm
8 x 60 8 x 80 8 x 100 10 x 60 10 x 80 10 x 100 10 x 120
10 20 40 10 10 30 50
6 6 6 8 8 8 8
h1 hmin hnom hef mm mm mm mm
df Tinst mm Nm
65 75 75 70 90 90 90
9 9 9 12 12 12 12
100 110 110 100 130 130 130
50 60 60 50 70 70 70
40 50 50 35 55 55 55
20 20 20 50 50 50 50
T
T30 T30 T30 T40 T40 T40 T40
Cmin Smin Ccr mm mm mm
45 45 45 55 55 55 55
45 45 45 55 55 55 55
75 90 90 75 105 105 105
Scr mm
150 180 180 150 210 210 210
Characteristic loads (kN) Estrazione Taglio
6,8 11,2 11,2 9,2 15,6 15,6 15,6
8,5 8,5 8,5 10,5 18,1 18,1 18,1
Pull-out and shear showed in the table are CHARACTERISTIC LOADS from tests run on non-cracked concrete C20/25 without edge and spacing effect (Pull-out and shear loads are in kN: 1kN = 100kg) Examples of applications
157
heavy duty anchors
CSB CE - CSB E - CSB S
through-setting heavy duty anchors
Vorpa VA Heavy duty anchor with European Technical Assesment for non cracked concrete
non cracked concrete
products group heavy duty anchors
VA CE [*] with internal thread
VA with internal thread
*
VA INOX A4 with internal thread
VA F CE [*] with internal thread
ETA version approved for • non-cracked concrete C20/25 C50/60 - M6-M16 • multiple use for non structural applications on non-cracked concrete C20/25 - C50/60 M6-M16 • anchorage under fire exposure TR 020 R30-R120
To fix • railings • plants engineering • beams • sections • ventilation systems and ceiling heating systems • ceiling lighting
All versions suitable for • non-cracked concrete • natural stone
VA F SVASATO with internal thread PERNO VA impacting tool
[*]
A4 INOX 316
ETAG 001-04 for non cracked concrete
ETAG 001-046 for multiple use in non cracked concrete for non structural applications
* R30-R120
CALCULATION SOFTWARE
product information Characteristics • steel anchor with internal thread and internal expansion cone to be used with bolts or threaded bars with European Technical Assesment for non cracked concrete and multiple use for non structural application • when the cone is driven in with the apposite impacting tool, the anchor sleeve is spread and thus expands against the hole wall • easy application and quick and safe installation thanks to the proper impacting tool, suitable for bars and accessories with metrical thread • the collar of the lipped type avoid the slipping of the anchor inside the hole • surface-flush anchor allows the attached items to be removed and refitted several times
Installation • pre-setting anchor • through-setting only in the version VA Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Examples of applications
158
through-setting heavy duty anchors
Vorpa VA Heavy duty anchor with European Technical Assesment for non cracked concrete
non cracked concrete
installation sequence heavy duty anchors
Clean the hole before the installation
product code and technical data VA CE [*] with internal thread Code
99591 99594 99592 99593
Description
Lt mm
do mm
h1 mm
For screws mm
Thread mm
VA.CE 8x30 VA.CE 8x40 VA.CE 10x40 VA.CE 12x50
30 40 40 50
10 10 12 15
30 40 40 50
M8 M8 M10 M12
13 20 15 18
VA F CE [*] lipped type with internal thread Code
98590 98591 98592 98593 98594
Description
Lt mm
do mm
h1 mm
For screws mm
Thread mm
VA F CE 8x30 VA F CE 8x40 VA F CE 10x30 VA F CE 10x40 VA F CE 12x50
30 40 30 40 50
10 10 12 12 15
30 40 30 40 50
M8 M8 M10 M10 M12
13 20 12 15 18 Screw length calculation: Lv= Lt + tfi
VA CE - VA F CE Installation data Anchor diameter Anchor length Effective anchorage depth Drill hole diameter Drill hole depth Hole diameter in the fixture Torque moment
d L hef do h1 df
Tinst ≤
mm mm mm mm mm mm Nm
M8 10 30 30 10 30 9 8
M10 12 40 40 12 40 12 15
M12 15 50 50 15 50 14 35
Critical axial spacing Critical edge distance Minimum thickness member
Scr,N Ccr,N hmin
mm mm mm
90 45 100
120 60 120
150 75 130
Characteristic values application in concrete non-cracked C20/25 Nrk,P C20/25 KN Pull out failure 11,3/13,5 Ψc C30/37 1,22 Ψc C40/50 1,41 Ψc C50/60 1,55
16,9 1,22 1,41 1,55
1 daN≃1 kg 24,1 1,22 1,41 1,55
Design loads Pull out failure
N
KN
3,3/3,6
5,1
1 daN≃ kg 7,1
Recommended loads Pull out failure
N
KN
2,3/2,5
3,6
1 daN≃1 kg 5
159
h1 = Min. hole depth Lt = Anchor length Lv = Screw length do = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
[*]
ETAG 001-04 for non cracked concrete
ETAG 001-046 for multiple use in non cracked concrete for non structural applications
through-setting heavy duty anchors
Vorpa VA Heavy duty anchor with European Technical Assesment for non cracked concrete
non cracked concrete
heavy duty anchors
product code and technical data VA INOX A4 with internal thread
VA with internal thread Code
590 591 592 593 594 595 7590 7591 7592 7593 7594 7595
A4 INOX 316
Description
Lt mm
Thread mm
For screws mm
do mm
h1 mm
Tinst Nm
VA 6 VA 8 VA 10 VA 12 VA 16 VA 20
25 30 40 50 65 80
12 13 15 18 23 34
M6 M8 M10 M12 M16 M20
8 10 12 15 20 25
30 35 45 55 70 85
4 8 15 35 60 120
VA INOX A4 VA INOX A4 VA INOX A4 VA INOX A4 VA INOX A4 VA INOX A4
25 30 40 50 65 80
12 13 15 18 23 34
M6 M8 M10 M12 M16 M20
8 10 12 15 20 25
30 35 45 55 70 85
4 8 15 35 60 120
6 8 10 12 16 20
Screw length calculation: Lv= Lt + tfi h1 = Min. hole depth Lt = Anchor length Lv = Screw length do = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
VA F SVASATO with internal thread Code
8590 8591 8592A 8592B 8593 8592 8594 8595
Description
Lt mm
Thread mm
For screws mm
do mm
h1 mm
Tinst Nm
VA F VA F VA F VA F VA F VA F VA F VA F
25 30 30 40 50 50 65 80
12 13 15 25 18 18 23 34
M6 M8 M10 M10 M12 M12 M16 M20
8 10 12 12 15 16 20 25
30 35 35 45 55 55 70 85
4 8 15 15 35 35 60 120
6 8 10/30 10/40 12Ø15 12Ø16 16 20
PERNO VA impacting tool Code
Description
295 296 298 299 300 1303
PERNO VA PERNO VA PERNO VA PERNO VA PERNO VA PERNO VA
VA thread mm
6 8 10 12 16 20
M6 M8 M10 M12 M16 M20
• Always respect the installation parameters • In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load
• The table shows the permissible loads for tension, shear and combined tension and shear loads
VA - VA F Installation data Critical axial spacing Scr Critical edge distance Ccr Minimum structural thickness hmin
mm mm mm
Permissible loads - applications in concrete C20/25 VA - VA A4 - VA F N daN
M6 220 105 170
M8 260 130 170
M10 340 170 220
M12 420 210 220
M16 530 265 245
85
160
400
600
790
160
M20 670 340 330 1 daN≃1 kg 1400
pre-setting heavy duty anchors
Vorpa TOP Heavy duty anchor with European Technical Assesment for non cracked concrete
concrete
natural stone
solid brick
products group TOP [*] TOP INOX A2 TOP INOX A4 [*] no accessories
* *
TOP BU [*] All versions suitable for TOP INOX A2 BU • non-cracked concrete TOP INOX A4 BU [*] • natural stone with hexagonal head screw
ETA version approved for • non-cracked concrete C20/25 C50/60 - M6-M12
• solid brick
TOP BP [*] with 8.8 hexagonal head screw and spacer
TOP TS with 10.9 countersunk head screw
* *
TOP BD TOP INOX A2 BD TOP INOX A4 BD with stud and nut
*
TOP OS TOP INOX A2 OS with eyebolt
TOP OP with eyebolt and spacer
*
[*]
A4 INOX
A2 INOX
*
*
316
ETAG 001-02 for non cracked concrete
TOP GS TOP INOX A2 GS with hook bolt
304
CALCULATION SOFTWARE
Examples of applications
161
To fix • steel structures • windows and door frames • railings and balustrades • gates • façades • machineries • iron bars
heavy duty anchors
* *
pre-setting heavy duty anchors
Vorpa TOP Heavy duty anchor with European Technical Assesment for non cracked concrete
natural stone
concrete
solid brick
heavy duty anchors
product information Characteristics • torque controlled expansion anchor made of galvanized steel or stainless steel composed of anti-rotation cold formed body, expansion conical nut and accessory with European Technical Assesment for non cracked concrete • wide range of accessories • anti-rotation during the installation procedure • fixing can be casily driven in, therefore less installation effort • surface-flush fixing allows the mounted item to be removed and refitted several times • anchor version with internal thread for high flexibility by using threaded rods or screws of different lengths and type
Installation • pre-setting anchor • through-setting only in the version TOP TS and TOP BP Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
installation sequence
Pre setting anchor TOP
Clean the hole before the installation
Through setting anchor TOP BP
product code and technical data TOP [*] no accessories Code
710 711 712 713
h1
Description
Lt mm
For screws mm
do mm
h1 mm
TOP 6 TOP 8 TOP 10 TOP 12
45 51 60 75
M6 M8 M10 M12
10 12 14 18
55 60 70 85 Screw length calculation: Lv= Lt + tfix
A2 INOX 304
TOP INOX A2 no accessories
A4 INOX TOP INOX A4 [*] 316
no accessories
Description
Lt mm
For screws mm
do mm
h1 mm
714 715 716 717
TOP INOX A2 6 TOP INOX A2 8 TOP INOX A2 10 TOP INOX A2 12
45 51 60 75
M6 M8 M10 M12
10 12 14 18
55 60 75 85
3714 3715 3716 3737
TOP INOX A4 6 TOP INOX A4 8 TOP INOX A4 10 TOP INOX A4 12
45 51 60 75
M6 M8 M10 M12
10 12 14 18
55 60 75 85
Code
162
h1 = Min. hole depth Lt = Anchor length Lv = Screw length do = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length
[*]
ETAG 001-02 for non cracked concrete
pre-setting heavy duty anchors
Vorpa TOP Heavy duty anchor with European Technical Assesment for non cracked concrete
natural stone
concrete
solid brick
product code and technical data
h1
Code
Description
Lt mm
Screw d x Lv mm
do mm
h1 mm
Tfix max mm
Tinst Nm
Ch
720 721 722 723
TOP 6 BU TOP 8 BU TOP 10 BU TOP 12 BU
45 51 60 75
M6x55 M8x65 M10x80 M12x100
10 12 14 18
55 60 70 85
10 14 20 25
10 25 40 75
10 13 17 19
TOP INOX A2 BU
TOP INOX A4 BU [*]
A2 INOX with A2 SS hexagonal 304
A4 INOX with A4 SS hexagonal 316
head screw
head screw
Description
Lt mm
Screw d x Lv mm
do mm
h1 mm
Tfix max mm
Tinst Nm
Ch
717 718 719 727
TOP INOX A2 6 BU TOP INOX A2 8 BU TOP INOX A2 10 BU TOP INOX A2 12 BU
45 51 60 75
M6x55 M8x65 M10x80 M12x100
10 12 14 18
55 60 70 85
10 14 20 25
10 25 40 75
10 13 17 19
3717 3718 3719 3720
TOP INOX A4 6 BU TOP INOX A4 8 BU TOP INOX A4 10 BU TOP INOX A4 12 BU
45 51 60 75
M6x55 M8x65 M10x80 M12x100
10 12 14 18
55 60 70 85
10 14 20 25
10 25 40 75
10 13 17 19
Code
TOP BP [*] with 8.8 hexagonal head screw and spacer
Code
Description
Lt mm
Screw d x Lv mm
do mm
h1 mm
Tfix max mm
Tinst Nm
Ch
2720 2721 2722 2723
TOP TOP TOP TOP
45 51 60 75
M6x80 M8x90 M10x100 M12x120
10 12 14 18
55 60 70 85
30 35 38 43
10 25 40 75
10 13 17 19
BP 10/30-80 BP 12/35-91 BP 14/38-100 BP 18/43-120
TOP TS with 10.9 countersunk head screw
Code
11864 11866 11868 11870
Description
Lt mm
Screw d x Lv mm
do mm
h1 mm
Tfix max mm
Tinst Nm
Ch
TOP TOP TOP TOP
45 51 60 75
M6x80 M8x90 M10x100 M12x120
10 12 14 18
55 60 75 85
32 40 40 46
10 25 40 75
4 5 6 8
TS 10/32-80 TS 12/40-90 TS 14/40-100 TS 18/46-120
163
heavy duty anchors
TOP BU [*] with 8.8 hexagonal head screw
h1 = Min. hole depth Lt = Anchor length Lv = Screw length do = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length
[*]
ETAG 001-02 for non cracked concrete
pre-setting heavy duty anchors
Vorpa TOP Heavy duty anchor with European Technical Assesment for non cracked concrete
concrete
natural stone
heavy duty anchors
product code and technical data
TOP OP with eyebolt and spacer
Code
Description
Lt mm
Eyebolt d x L0 mm
do mm
h1 mm
Tinst Nm
Ø
2572 2573
TOP 10 OP Ø14 TOP 10 OP Ø23
60 60
M10x100 M10x100
14 14
95 95
20 20
14,5±0,5 23±0,5
TOP OS with eyebolt
TOP INOX A2 OS A2 INOX with A2 SS eyebolt 304
Code
Description
Lt mm
Eyebolt d x L0 mm
do mm
h1 mm
Tinst Nm
Ø
795 796 797 798
TOP 6 OS TOP 8 OS TOP 10 OS TOP 12 OS
45 51 60 75
M6x55 M8x60 M10x73 M12x90
10 12 14 18
55 60 70 85
5 12 20 35
10±0,5 11,8±0,5 14,5±0,5 17±0,5
TOP INOX A2 6 OS TOP INOX A2 8 OS TOP INOX A2 10 OS TOP INOX A2 12 OS
45 51 60 75
M6x55 M8x60 M10x73 M12x90
10 12 14 18
55 60 70 85
6 15 30 50
10±0,5 11,8±0,5 14,5±0,5 17±0,5
3795 3796 3797 3798
TOP GS with hook bolt
TOP INOX A2 GS with A2 SS hook bolt
Code
Description
Lt mm
Hook d x Lg mm
do mm
h1 mm
Tinst Nm
P
775 776 777 778
TOP 6 GS TOP 8 GS TOP 10 GS TOP 12 GS
45 51 60 75
M6x55 M8x60 M10x73 M12x90
10 12 14 18
55 60 70 85
5 12 20 35
8±0,5 10±0,5 12,5±0,5 16±0,5
T OP INOX A2 6 GS TOP INOX A2 8 GS TOP INOX A2 10 GS TOP INOX A2 12 GS
45 51 60 75
M6x55 M8x60 M10x73 M12x90
10 12 14 18
55 60 70 85
6 15 30 50
8±0,5 10±0,5 12,5±0,5 16±0,5
3775 3776 3777 3778
Examples of applications
164
A2 INOX 304
h1 = Min. hole depth Lt = Anchor length Lv = Screw length do = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length
solid brick
pre-setting heavy duty anchors
Vorpa TOP Heavy duty anchor with European Technical Assesment for non cracked concrete
concrete
natural stone
solid brick
product code and technical data
Code Description
705 706 707 708
TOP 6 BD 57 TOP 8 BD 75 TOP 10 BD 90 TOP 12 BD 110
Lt mm
For screws d x Lb mm
do mm
h1 mm
Tfix max mm
Tinst Nm
Ch
45 51 60 75
M6x57 M8x75 M10x90 M12x110
10 12 14 18
55 60 70 85
10 10 20 25
6 15 30 50
10 13 17 19
A2 INOX 304
Code Description
TOP INOX A2 BD with A2 SS stud and nut
heavy duty anchors
TOP BD with stud and nut
h1 = Min. hole depth Lt = Anchor length Lv = Screw length do = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length
A4 INOX TOP INOX A4 BD 316
with A4 SS stud and nut
Lt mm
For screws d x Lb mm
do mm
h1 mm
Tfix max mm
Tinst Nm
Ch
25705 TOP 6 BD A2 57 25706 TOP 8 BD A2 75 25707 TOP 10 BD A2 90
45 51 60
M6x55 M8x75 M10x90
10 12 14
55 60 70
10 10 20
10 25 40
10 13 17
5705 TOP 6 BD A4 57 5706 TOP 8 BD A4 75 5707 TOP 10 BD A4 90
45 51 60
M6x55 M8x75 M10x90
10 12 14
55 60 70
10 10 20
10 25 40
10 13 17
Examples of applications
TOP anchor not certified Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness
Scr Ccr Smin Cmin hmin
mm mm mm mm mm
M6 120 60 65 45 135
M8 135 75 90 70 135
M10 155 90 135 85 140
M12 190 120 165 115 160
daN daN daN daN daN
370 250 140 35 200
490 400 240 75 350
600 500 360 105 470
720 650 600 160 630
Permissible loads - applications in concrete C20/25 TOP TS TOP BD-TOP BD A2-TOP BD A4 TOP OS-TOP OS A2-TOP OP TOP GS-TOP GS A2 TOP A2
1 daN≃1 kg
• Always respect the installation parameters • In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load • The table shows the permissible loads for tension, shear and combined tension and shear loads 165
pre-setting heavy duty anchors
Vorpa TOP Heavy duty anchor with European Technical Assesment for non cracked concrete
concrete
natural stone
solid brick
heavy duty anchors
technical data TOP CE M6
M8
M10
M12
mm mm mm mm mm mm mm Nm
10 45 39,5 10 10 55 7 10
12 51 44,5 14 12 60 9 25
14 60 51,5 20 14 70 12 40
18 75 63 25 18 85 14 75
Scr,N Ccr,N Smin Cmin hmin
mm mm mm mm mm
120 60 65 45 135
135 75 90 70 135
155 90 135 85 140
190 120 165 115 160
Installation data TOP BP Anchor diameter Anchor length Effective anchorage depth Fixture thickness Drill hole diameter Drill hole depth Hole diameter in the fixture Torque moment
d L hef Tfix do h1 df Tinst
mm mm mm mm mm mm mm Nm
10 80 40,5 30 10 55 12 10
12 90 45,5 35 12 60 14 25
14 100 48,5 38 14 70 18 40
18 120 57 43 18 85 20 75
Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum thickness member
Scr,N Ccr,N Smin Cmin hmin
mm mm mm mm mm
120 60 65 45 5
135 75 90 70 135
155 90 135 85 140
190 120 165 115 160
Nrk,P C20/25
KN
9 1,17 1,33 1,5
12
16
20 1,22 1,41 1,55
VRk,S C20/25 MRK,S
KN Nm
8 12,2
14,6 30
23,2 59,8
33,7 104,8
Nrk,P C20/25
KN
7,5 1,17 1,33 1,5
9
12
16 1,22 1,41 1,55
VRk,S C20/25 MRK,S
KN Nm
7 10,7
12,8 26,2
20,3 52,3
29,5 91,7
Values where the reduction factor is included TOP A4 – TOP BU A4 (Design loads) Nrk,P KN Pull out failure VRk,S KN Shear failure MRK,S Nm Bending moment
5 4,5 6,8
5 8,2 16,8
6,6 13 33,3
8,8 18,9 58,8
Values where the reduction factor Pull out failure Shear failure Bending moment
5 6,4 9,7
5,7 11,6 24
7,6 18,5 47,8
13,3 26,9 83,8
KN KN Nm
3,5 3,2 4,9
3,5 5,8 12
4,7 9,3 23,8
6,3 13,5 42
KN KN Nm
3,5 4,5 6,9
4 8,3 17,1
5,4 13,2 34,1
9,5 19,2 59,8
Installation data TOP –TOP A4 –TOP BU – TOP BU A4 Anchor diameter Anchor length Effective anchorage depth Fixture thickness Drill hole diameter Drill hole depth Hole diameter in the fixture Torque moment
d L hef Tfix do h1 df Tinst
Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum thickness member
Characteristic values TOP – TOP BU – TOP BP Pull out failure ψc C30/37 ψc C40/50 ψc C50/60 Shear failure Bending moment Characteristic values TOP A4 – TOP BU A4 Pull out failure ψc C30/37 ψc C40/50 ψc C50/60 Shear failure Bending moment
is included TOP BU – TOP BP (Design loads) Nrk,P KN VRk,S KN MRK,S Nm
Recommended loads TOP A4 - TOP BU A4 Pull out failure Shear failure Bending moment Recommended loads TOP - TOP BU - BP Pull out failure Shear failure Bending moment
N T M
166
pre-setting heavy duty anchors
Vorpa TOP SA Steel anchor
concrete
pre-stressed concrete hollow ceiling slabs
natural stone
products group
*
TOP SA BU TOP SA INOX A4 BU with hexagonal head screw
*
TOP SA BD TOP SA INOX A4 BD with stud and nut
Suitable for • concrete • pre-stressed concrete hollowceiling slabs • natural stone
To fix • light metal structural work • brackets and rails for industrial systems such as lighting, heating, ventilation • suspended ceilings • pipelines • timber constructions • sprinkler systems
A4 INOX Test report available
316 *
product information Characteristics • special short body steel anchor with anti-rotation design and expansion conical nut • the special design of the anchor allows the use both in hollow materials such as pre-stressed concrete hollow-core slabs both in solid materials with reduced thickness up to 5 cm • the collar prevents slippage of the anchor into the hole and facilitates the installation since it is not necessary to respect the depth of drilling • the optimized geometry reduces the energy required for fixing and allows its use even in narrowed spaces • suitable for all types of screws, threaded rods and eyebolts with metric thread
Installation • pre-setting anchor Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
areas of applications
5 cm min.
Examples of applications
167
heavy duty anchors
*
TOP SA TOP SA INOX A4 no accessories
pre-setting heavy duty anchors
Vorpa TOP SA Steel anchor
concrete
pre-stressed concrete hollow ceiling slabs
natural stone
heavy duty anchors
installation sequence
Clean the hole before the installation
product code and technical data
TOP SA no accessories Code zincplated
Code inox A4
9650 9651 9652
Description
Code inox A4
9659 9660 9661
do mm
h1 mm
6 8 10
38 43 52
M6 M8 M10
10 12 14
45 55 60
38 43 52
10 10 20
TOP SA A4 6 TOP SA A4 8 TOP SA A4 10
38 43 52
M6 M8 M10
10 12 14
45 55 60
38 43 52
10 10 20
Description
TOP SA TOP SA TOP SA 9665 9666 9667
Code inox A4
9690 9691 9692
Lt mm
Lv
T inst
A4 INOX 316
Screw dxLv
do mm
h1 mm
Tfix max
Tinst mm
Ch
38 43 52
M6x50 M8x60 M10x70
10 12 14
45 55 60
8 12 17
10 10 20
10 13 17
TOP SA A4 6 BU TOP SA A4 8 BU TOP SA A4 10 BU
38 43 52
M6x50 M8x60 M10x70
10 12 14
45 55 60
8 12 17
10 10 20
10 13 17
TOP SA INOX A4 BD with A4 SS stud and nut
Description
Lt mm
A4 INOX 316
Stud dxLb
do mm
h1 mm
Tfix max
Tinst mm
Ch
6 BD 8 BD 10 BD
38 43 52
M6x57 M8x80 M10x90
10 12 14
45 55 60
8 12 17
10 10 20
10 13 17
TOP SA A4 6 BD TOP SA A4 8 BD TOP SA A4 10 BD
38 43 52
M6x57 M8x80 M10x90
10 12 14
45 55 60
8 12 17
10 10 20
10 13 17
168
Ch
h1 = Min. hole depth Lt = Anchor length Lv = Screw length do = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
6 BU 8 BU 10 BU
TOP SA TOP SA TOP SA 9695 9696 9697
Prof. min. Tinst avvit. mm mm
TOP SA INOX A4 BU with A4 SS hexagonal head screw
TOP SA BD with stud and nut
Art. zincplated
316
Screws
TOP SA BU with hexagonal head screw Art. zincplated
A4 INOX
Lt mm
TOP SA TOP SA TOP SA 9655 9656 9657
TOP SA INOX A4 no accessories
T fix
pre-setting heavy duty anchors
Vorpa TOP SA Steel anchor
concrete
pre-stressed concrete hollow ceiling slabs
natural stone
technical data
1 kN≃100 kg
Permissible loads-single application of anchor with 8.8 class screw on hollow prestressed concrete slab class ≥B55 (≥C45/55) Anchor
TOP SA M6
TOP SA M8 TOP SA M10
Slab thickness du (mm) 25-29 30-39 ≥40 25-29 30-39 ≥40 30-39 ≥40
Effective anchorage depth hef (mm) 35 35 35 40 40 40 45 45
Torque Tinst (Nm) 10 10 10 10 10 10 20 20
Permissible load Kn 0,6 0,8 1,9 0,6 0,8 1,9 1,1 2,9
Minimum spacing (mm) 75 85 105 75 85 105 85 105
Minimum edge distance (mm) 110 110 110 110 110 110 110 110
Permissible loads-single application of anchor with A4 screw on hollow prestressed concrete slab class ≥B55 (≥C45/55) Anchor
TOP SA A4 M6
TOP SA A4 M8 TOP SA A4 M10
Slab thickness du (mm) 25-29 30-39 ≥40 25-29 30-39 ≥40 30-39 ≥40
Effective anchorage depth hef (mm) 35 35 35 40 40 40 45 45
Torque Tinst (Nm) 10 10 10 10 10 10 20 20
Permissible load Kn 0,54 0,72 1,70 0,54 0,72 1,70 0,99 2,61
Minimum spacing (mm) 75 85 105 75 85 105 85 105
Minimum edge distance (mm) 110 110 110 110 110 110 110 110
Permissible loads-single application of anchor with threaded road class screw on hollow prestressed concrete slab class ≥B55 (≥C45/55) Anchor
TOP SA BD A4 M6
TOP SA BD A4 M8 TOP SA BD A4 M10
Slab thickness du (mm) 25-29 30-39 ≥40 25-29 30-39 ≥40 30-39 ≥40
Effective anchorage depth hef (mm) 35 35 35 40 40 40 45 45
Torque Tinst (Nm) 10 10 10 10 10 10 20 20
Examples of applications
169
Permissible load Kn 0,51 0,68 1,61 0,51 0,68 1,61 0,93 2,46
Minimum spacing (mm) 75 85 105 75 85 105 85 105
Minimum edge distance (mm) 110 110 110 110 110 110 110 110
heavy duty anchors
TOP SA
pre-setting heavy duty anchors
Vorpa AV Steel anchor
concrete
natural stone
solid brick
products group heavy duty anchors
AV
* AV INOX A2
no accessories AV BU
Suitable for • concrete • natural stone • solid brick
* AV INOX A2 BU
with hexagonal head screw AV BD
* AV INOX A2 BD
with stud and nut
To fix • stairs • window elements • railings and balustrades • pipes • steel structures • gates • façades • machineries • bars
AV OS with eyebolt
AV OA with folded hook bolt
AV GS with hook bolt
A2 INOX
304 *
installation sequence
Clean the hole before the installation
product information Characteristics • expansion anchor made of galvanized steel or stainless steel composed of anti-rotation cold formed body, expansion conical nut and accessory • wide range of accessories, anti-rotation design with two lateral wings • surface-flush fixing allows the attached item to be removed and refitted several times • plastic cap protects against contamination with drilling dust and ensures the thread remains free-running
Installation • pre-setting anchor Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Examples of applications
170
pre-setting heavy duty anchors
Vorpa AV Steel anchor
concrete
natural stone
solid brick
product code and technical data
Code Description
550 551 552 553 554 3550 3551 3552 3547
AV INOX A2 no accessories
Lt mm
For screw mm
do mm
h1 mm
AV 6 AV 8 AV 10 AV 12 AV 16
47 55 65 75 92
M6 M8 M10 M12 M16
12 14 16 20 24
55 65 75 85 105
AV INOX A2 6 AV INOX A2 8 AV INOX A2 10 AV INOX A2 12
47 55 65 75
M6 M8 M10 M12
12 14 16 20
55 65 75 85
AV BU with 8.8 hexagonal head screw Code Description
260 262 263 264 261
AV 6 BU AV 8 BU AV 10 BU AV 12 BU AV 16 BU
3260 3262 3263 3264
AV INOX A2 AV INOX A2 AV INOX A2 AV INOX A2
6 BU 8 BU 10 BU 12 BU
Code Description
250 251 252 255 256 257 253 254 259
AV 6 BD 60 AV 8 BD 50 AV 8 BD 75 AV 8 BD 100 AV 8 BD 120 AV 8 BD 130 AV 10 BD 85 AV 12 BD 105 AV 16 BD 135
3250 AV INOX A2 6 BD 60 3252 AV INOX A2 8 BD 75 3253 AV INOX A2 10 BD 85
A2 INOX 304
Screw length calculation: Lv= Lt + tfix
AV INOX A2 BU with hexagonal head screw
A2 INOX 304
Lt mm
Screw d x Lv mm
do mm
h1 mm
Tfix max mm
Tinst Nm
Ch
47 55 65 75 92
M6x55 M8x65 M10x80 M12x100 M16x100
12 14 16 20 24
55 65 75 85 105
10 12 15 20 20
10 25 50 85 150
10 13 17 19 24
47 55 65 75
M6x55 M8x65 M10x80 M12x100
12 14 16 20
55 65 75 85
10 15 15 20
10 25 50 85
10 13 17 19
AV BD with stud and nut
AV INOX A2 BD A2 INOX with stud and nut 304
Lt mm
Stud d x Lv mm
do mm
h1 mm
Tfix max mm
Tinst Nm
Ch
47 30 55 55 55 55 65 75 92
M6x60 M8x55 M8x75 M8x100 M8x120 M8x132 M10x85 M12x115 M16x135
12 14 14 14 14 14 16 20 24
55 65 65 65 65 65 75 85 105
10 5 15 35 55 65 15 25 30
6 15 15 15 15 15 30 50 70
10 13 13 13 13 13 17 19 24
47 55 65
M6x60 M8x75 M10x85
12 14 16
55 65 75
10 15 15
10 25 40
10 13 17
171
heavy duty anchors
AV no accessories
h1 = Min. hole depth Lt = Anchor length Lv = Screw length do = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length
pre-setting heavy duty anchors
Vorpa AV Steel anchor
concrete
natural stone
product code and technical data heavy duty anchors
AV OS with eyebolt
Code
Description
Lt mm
Eyebolt d x L0 mm
do mm
h1 mm
Tinst Nm
Ø
280 281 282 283 284
AV 6 OS AV 8 OS AV 10 OS AV 12 OS AV 16 OS
47 55 65 75 92
M6x55 M8x60 M10x73 M12x90 M16x95
12 14 16 20 24
55 65 75 85 105
5 12 25 40 80
10±0,5 11,8±0,5 14,5±0,5 17±0,5 23±0,5
AV GS with hook bolt
Code
Description
Lt mm
Hook bolt d x Lg mm
do mm
h1 mm
Tinst Nm
P
290 291 292 293 294
AV 6 GS AV 8 GS AV 10 GS AV 12 GS AV 16 GS
47 55 65 75 92
M6x55 M8x60 M10x73 M12x90 M16x95
12 14 16 20 24
55 65 75 85 105
5 12 25 40 80
8±0,5 10±0,5 12,5±0,5 16±0,5 19±0,5
AV OA with folded hook bolt
Code
Description
Lt mm
Hook bolt d x Lg mm
do mm
h1 mm
Tinst Nm
P
311 312
AV 6 OA AV 8 OA
47 55
M6x55 M8x65
12 14
55 65
5 12
13±0,5 16±0,5
AV Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness
Scr Ccr Smin Cmin hmin
mm mm mm mm mm
AV M6 160 90 70 60 100
AV M8 180 100 80 70 100
AV M10 220 120 90 80 100
AV M12 280 150 120 100 120
Permissible loads - applications in concrete C20/25 AV BU - AV BU A2/A4 AV - AV A2/A4 - AV BD AV OS AV GS AV OA screws A2/A4
daN daN daN daN daN daN
AV M16 AV M20 320 440 170 185 130 145 115 125 140 160 1 daN≃1 kg
230 220 140 35 35 230
420 350 240 75 75 420
590 470 360 100 100 590
750 700 600 110 110
1080 800 700 200
1250 950
• Always respect the installation parameters • In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load • The table shows the permissible loads for tension, shear and combined tension and shear loads 172
h1 = Min. hole depth Lt = Anchor length Lv = Screw length do = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length
solid brick
pre-setting heavy duty anchors
Vorpa AVZ Steel anchor
concrete
natural stone
solid brick
products group Suitable for • concrete • natural stone • solid brick
AVZ BU with 8.8 hexagonal head screw
AVZ OS with eyebolt
To fix • stairs • window elements • railings and balustrades • pipes • steel structures • gates • façades • machineries • bars
product information Characteristics • steel anchor composed of 4 segments anti-rotation cold formed body, expansion conical nut and accessory • anti-rotation during the installation procedure • smooth expansion thanks to the four segments body • suitable for applications on poor-quality concrete and nonhomogeneous materials • high expansion and grip
Installation • pre-setting anchor Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
installation sequence
Clean the hole before the installation
Examples of applications
173
heavy duty anchors
AVZ no accessories
pre-setting heavy duty anchors
Vorpa AVZ Steel anchor
concrete
natural stone
solid brick
heavy duty anchors
product code and technical data AVZ no accessories Code
831 832 833 834 835
Description
Lt mm
For screws mm
do mm
h1 mm
AVZ 6 AVZ 8 AVZ 10 AVZ 12 AVZ 16
40 50 60 80 100
M6 M8 M10 M12 M16
10 14 16 20 25
50 60 70 90 110
Screw length calculation: Lv= Lt + tfix
AVZ BU with 8.8 hexagonal head screw
Code
841 842 843 844 845
Description
Lt mm
Screw d x Lv mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
AVZ AVZ AVZ AVZ AVZ
40 50 60 80 100
M6x55 M8x70 M10x80 M12x100 M16x130
10 14 16 20 25
50 60 70 90 110
15 20 20 20 25
10 25 50 85 150
10 13 17 19 24
6 BU 8 BU 10 BU 12 BU 16 BU
h1 = Min. hole depth Lt = Anchor length Lv = Screw length do = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner L0 = Eyebolt length
AVZ OS with eyebolt Code
Description
Lt mm
Eyebolt d x Lo mm
do mm
h1 mm
Tinst Nm
Ø
3280 3281 3282 3283
AVZ 6 OS AVZ 8 OS AVZ 10 OS AVZ 12 OS
40 50 60 80
M6x55 M8x60 M10x73 M12x90
10 14 16 20
50 60 70 90
15 20 20 6
10±0,5 11,8±0,5 14,5±0,5 17±0,5
AVZ Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness
Scr Ccr Smin Cmin hmin
mm mm mm mm mm
AVZ M6 200 100 80 50 100
AVZ M8 220 100 80 50 100
AVZ M10 260 130 100 65 150
AVZ M12 320 160 130 80 160
Permissible loads - applications in concrete C20/25 AVZ BU AVZ OS
AVZ M16 440 220 170 110 220 1 daN≃1 kg
daN daN
330 140
450 240
530 360
• Always respect the installation parameters • In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load • The table shows the permissible loads for tension, shear and combined tension and shear loads 174
750 600
1200
pre-setting heavy duty anchors
Vorpa VHM Zamak expansion shield anchor
concrete
natural stone
solid brick
products group Suitable for • concrete • natural stone • solid brick
VHM BU with 8.8 hexagonal head screw
To fix • stairs • window elements • railings and balustrades • pipes • steel structures • gates • façades • machineries • bars
product information Characteristics • zamak anchor composed of 4 shells cold formed body, with antirotation design, expansion conical nut and accessory • anti-rotation during the installation • no corrosion body, suitable for wet area, old and non-homogeneous materials • smooth expansion thanks to the four shells body • the body is made of zamak (96% zinc. 4% alluminium)
Installation • pre-setting anchor Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
installation sequence
Clean the hole before the installation
Examples of applications
175
heavy duty anchors
VHM no accessories
pre-setting heavy duty anchors
Vorpa VHM Zamak expansion shield anchor
concrete
natural stone
solid brick
heavy duty anchors
product code and technical data VHM no accessories Code
811 812 813 814 815
Description
Lt mm
For screws mm
do mm
h1 mm
VHM 6 VHM 8 VHM 10 VHM 12 VHM 16
47 50 57 72 107
M6 M8 M10 M12 M16
12 14 16 20 25
55 60 70 80 115
Screw length calculation: Lv= Lt + tfix
VHM BU with 8.8 hexagonal head screw Code
Description
Lt mm
Screw d x Lv mm
do mm
h1 mm
Tfix max mm
Tinst Nm
Ch
821 822 823 824 825
VHM 6 BU VHM 8 BU VHM 10 BU VHM 12 BU VHM 16 BU
47 50 57 72 107
M6x55 M8x70 M10x80 M12x100 M16x150
12 14 16 20 25
55 60 70 80 115
10 15 20 20 20
10 25 50 80 150
10 13 17 19 24
h1 = Min. hole depth Lt = Anchor length Lv = Screw length do = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
Examples of applications
VHM Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness
Scr Ccr Smin Cmin hmin
mm mm mm mm mm
VHM M6 200 100 85 50 100
VHM M8 220 100 85 50 100
VHM M10 260 130 105 65 150
VHM M12 320 160 135 80 160
Permissible loads - applications in concrete C20/25 VHM BU
VHM M16 440 225 180 110 200 1 daN≃1 kg
daN
300
400
500
• Always respect the installation parameters • In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load • The table shows the permissible loads for tension, shear and combined tension and shear loads 176
600
1200
pre-setting heavy duty anchors
Vorpa AVZ.G Sherardise steel shield anchor
concrete
natural stone
solid brick
products group Suitable for • concrete • natural stone • solid brick
AVZ.G BU with 8.8 hexagonal head screw
To fix • stairs • window elements • railings and balustrades • pipes • steel structures • gates • façades • machineries • bars
product information Characteristics • steel anchor made of sherardise steel composed of 4 segments anti-rotation cold formed body, expansion conical nut and steel spring plus accessory. • anti-rotation during the installation procedure • smooth expansion thanks to the four segments body • indicated also for oversize holes • suitable for porous and non-homogeneous materials; • it can be used even in case of defective base materials.
Installation • pre-setting anchor Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
installation sequence
Clean the hole before the installation
Examples of applications
177
heavy duty anchors
AVZ.G no accessories
pre-setting heavy duty anchors
Vorpa AVZ.G Sherardise steel shield anchor
concrete
natural stone
solid brick
heavy duty anchors
product code and technical data AVZ.G no accessories Code.
Description
Lt mm
For screws mm
do mm
h1 mm
1831 1832 1833 1834 1835
AVZ.G 6 AVZ.G 8 AVZ.G 10 AVZ.G 12 AVZ.G 16
40 50 60 80 100
M6 M8 M10 M12 M16
12 14 16 20 28
45 55 65 85 105
Screw length calculation: Lv= Lt + tfix
AVZ.G BU with 8.8 hexagonal head screw Code
Description
Lt mm
Screw d x Lv mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
1841 1842 1843 1844 1845
AVZ.G 6 BU AVZ.G 8 BU AVZ.G 10 BU AVZ.G 12 BU AVZ.G 16 BU
40 50 60 80 100
M6x55 M8x70 M10x80 M12x100 M16x130
12 14 16 20 28
45 55 65 85 105
15 20 20 20 25
10 25 50 85 150
10 13 17 19 24
h1 = Min. hole depth Lt = Anchor length Lv = Screw length do = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
Examples of applications
AVZ.G Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness
Scr Ccr Smin Cmin hmin
mm mm mm mm mm
AVZ.G M6 200 100 85 50 100
AVZ.G M8 220 100 85 50 100
AVZ.G 260 130 105 65 150
AVZ.G M12 320 160 135 80 160
Permissible loads - applications in concrete C20/25 AVZ.G BU
AVZ.G M16 440 220 170 110 220 1 daN≃1 kg
daN
370
580
760
• Always respect the installation parameters • In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load • The table shows the permissible loads for tension, shear and combined tension and shear loads 178
1140
2000
through-setting heavy duty anchors
Vorpa VHS Heavy duty anchor with European Technical Assesment for non cracked concrete
concrete
natural stone
solid brick
products group
VHS B with stud and nut
*
ETA version approved for • non-cracked concrete C20/25 - C50/60 - M6-M12 All versions suitable for • non-cracked concrete • natural stone • solid brick
To fix • plates • plants engineering • stairs • window and door frames • profiles • gates • railings
VHS F VHS FI INOX A2 with countersunk head screw
VHS OS with eyebolt
[*]
A2 INOX
304 *
CALCULATION SOFTWARE
ETAG 001-02 for non cracked concrete
VHS PF with 8.8 hexagonal head screw
(cen/ts 1992-4 Metodo A)
product information Characteristics • through steel anchor with slots on the body and on the expansion conical nut with European Technical Assessment for non cracked concrete • smooth expansion thanks to the slots on the body and on the expansion conical nut • high setting quickness through the object to be fixed • high performances
Installation • through-setting anchor Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
installation sequence
Clean the hole before the installation
Examples of applications
179
heavy duty anchors
*
VHS C [*] VHS D INOX A2 with hexagonal head screw
through-setting heavy duty anchors
Vorpa VHS Heavy duty anchor with European Technical Assesment for non cracked concrete
concrete
natural stone
solid brick
heavy duty anchors
product code and technical data VHS C [*] with 8.8 hexagonal head screw Code Description
* 1725 1726 *1726L 1724 * 1727 1728 5567 3473 4473 * 1729 1730 3475 4475 * 1732 5560 5561 5562
VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C
8/4-45 8/24-65 8/35-80 8/54-100 10/5-50 10/25-70 10/35-80 10/45-100 10/65-120 12/5-60 12/25-80 12/45-100 12/65-120 12/75-130 16/10-90 16/30-110 16/50-130
Lt mm
Screw d x Lv mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
45 65 80 100 50 70 80 100 120 60 80 100 120 130 90 110 130
M6x50 M6x70 M6x80 M6x100 M8x55 M8x75 M8x80 M8x100 M8x120 M10x65 M10x80 M10x100 M10x120 M10x130 M12x90 M12x110 M12x130
8 8 8 8 10 10 10 10 10 12 12 12 12 12 16 16 16
50 50 50 50 55 55 55 55 55 60 60 60 60 60 85 85 85
4 24 35 54 5 25 35 45 65 5 25 45 65 75 10 30 50
10 10 10 10 25 25 25 25 25 40 40 40 40 40 65 65 65
10 10 10 10 13 13 13 13 13 17 17 17 17 17 19 19 19
h1 = Min. hole depth Lt = Anchor length Lv = Screw length do = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length
[*]
* Not included in ETA VHS D INOX A2 with A2 SS hexagonal head screw
A2 INOX 304
ETAG 001-02 for non cracked concrete (cen/ts 1992-4 Metodo A)
Code Description
Lt mm
Screw d x Lv mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
2525 2526 5483 2500 2527 2528 5480 2473 5473 2529 2530 2475 5475 5476 5477 5479
45 65 80 100 50 70 80 100 120 60 80 100 120 90 110 130
M6x50 M6x70 M6x80 M6x100 M8x55 M8x75 M8x80 M8x100 M8x120 M10x65 M10x80 M10x100 M10x120 M12x90 M12x110 M12x130
8 8 8 8 10 10 10 10 10 12 12 12 12 16 16 16
50 50 50 50 55 55 55 55 55 60 60 60 60 85 85 85
4 24 35 54 5 25 35 45 65 5 25 45 65 10 30 50
10 10 10 10 25 25 25 25 25 40 40 40 40 65 65 65
10 10 10 10 13 13 13 13 13 17 17 17 17 19 19 19
VHS D A2 8/4-45 VHS D A2 8/24-65 VHS D A2 8/35-80 VHS D A2 8/54-100 VHS D A2 10/5-50 VHS D A2 10/25-70 VHS D A2 10/35-80 VHS D A2 10/45-100 VHS D A2 10/65-120 VHS D A2 12/5-60 VHS D A2 12/25-80 VHS D A2 12/45-100 VHS D A2 12/65-120 VHS D A2 16/10-90 VHS D A2 16/30-110 VHS D A2 16/50-130
VHS OS with eyebolt
Code Description
575 VHS OS 8/45 576 VHS OS 10/50 577 VHS OS 12/60
Lt mm
Eyebolt d x LO mm
do mm
h1 mm
Tinst Nm
Ø
45 50 60
M6x55 M8x60 M10x73
8 10 12
55 60 85
6 15 30
10±0,5 11,8±0,5 14,5±0,5
180
through-setting heavy duty anchors
Vorpa VHS Heavy duty anchor with European Technical Assesment for non cracked concrete
concrete
natural stone
solid brick
product code and technical data heavy duty anchors
VHS B with stud and nut
Code
535 536 2534 537 538 2538 52535 539 540 2540 2541 55561 55562 52536
Description
Lt mm
Screw d x Lb mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
VHS B VHS B VHS B VHS B VHS B VHS B VHS B VHS B VHS B VHS B VHS B VHS B VHS B VHS B
45 65 100 50 70 100 130 60 80 100 120 110 130 140
M6x57 M6x73 M6x110 M8x60 M8x80 M8x102 M8x132 M10x75 M10x95 M10x110 M10x130 M12x110 M12x130 M12x140
8 8 8 10 10 10 10 12 12 12 12 16 16 16
50 50 50 55 55 55 55 60 60 60 60 85 85 85
4 24 54 5 25 45 60 5 25 45 65 30 50 60
6 6 6 15 15 15 15 30 30 30 30 65 65 65
10 10 10 13 13 13 13 17 17 17 17 19 19 19
8/4-45 8/24-65 8/54-100 10/5-50 10/25-70 10/45-100 10/60-130 12/5-60 12/25-80 12/45-100 12/65-120 16/30-110 16/50-130 16/60-140
VHS F with 10.9 countersunk head screw
Code
Description
Lt mm
Screw d x Lv mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
4525 4526 4537 4527 4528 4534 4529 4530 4535 5565 5566
VHS F VHS F VHS F VHS F VHS F VHS F VHS F VHS F VHS F VHS F VHS F
45 65 100 50 70 100 60 80 100 90 110
M6x50 M6x70 M6x100 M8x60 M8x80 M8x100 M10x65 M10x80 M10x100 M12x90 M12x110
8 8 8 10 10 10 12 12 12 16 16
50 50 50 55 55 55 60 60 60 85 85
8 28 58 10 30 50 10 30 50 15 35
10 10 10 25 25 25 40 40 40 65 65
4 4 4 5 5 5 6 6 6 8 8
8/8-45 8/28-65 8/58-100 10/10-50 10/30-70 10/50-100 12/10-60 12/30-80 12/50-100 16/15-90 16/35-110
VHS FI INOX A2 with A2 SS countersunk head screw
A2 INOX 304
Code
Description
Lt mm
Screw d x Lv mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
5530 5531 5537 5532 5533 5529 5534 5535 5536
VHS FI A2 8/8-45 VHS FI A2 8/28-65 VHS FI A2 8/58-100 VHS FI A2 10/10-50 VHS FI A2 10/30-70 VHS FI A2 10/50-100 VHS FI A2 12/10-60 VHS FI A2 12/30-80 VHS FI A2 12/50-100
45 65 100 50 70 100 60 80 100
M6x50 M6x70 M6x100 M8x60 M8x80 M8x100 M10x65 M10x80 M10x100
8 8 8 10 10 10 12 12 12
50 50 50 55 55 55 60 60 60
8 28 58 10 30 50 10 30 50
10 10 10 25 25 25 40 40 40
4 4 4 5 5 5 6 6 6
181
h1 = Min. hole depth Lt = Anchor length Lv = Screw length do = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length
through-setting heavy duty anchors
Vorpa VHS Heavy duty anchor with European Technical Assesment for non cracked concrete
concrete
natural stone
solid brick
heavy duty anchors
technical data VHS CE M6
M8
M10
M12
Anchor diameter Effective anchorage depth Drill hole diameter Drill hole depth Hole diameter in the fixture Torque moment
d hef do h1 df Tinst
mm mm mm mm mm Nm
8 31 8 50 9 10
10 35 10 55 11 25
12 40 12 60 13 40
16 60 16 85 17 65
Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum thickness member
Scr,N Ccr,N Smin Cmin hmin
mm mm mm mm mm
93 46,5 95 50 80
105 52,5 120 60 100
120 60 145 75 120
180 90 175 90 150
Nrk,P C20/25
KN
6 1 1 1
7,5 1 1 1
12 1 1 1
20 1 1 1
VRk,S C20/25 MRK,S
KN Nm
7,5 12,2
12 30
20 59,8
30 104,8
Nrk,P VRk,S MRK,S
KN KN Nm
4 6 9,7
5 9,6 24
8 16 47,8
13 24 83,8
N T M
KN KN Nm
2,5 4,2 6,5
3,5 6,8 17
5,7 11,4 34
9,2 17 59,5
Characteristic values VHS C Pull out failure Ψc C30/37 Ψc C40/50 Ψc C50/60 Shear failure Bending moment Values where the reduction factor Pull out failure Shear failure Bending moment Recommended loads VHS C Pull out failure Shear failure Bending moment
VHS FI - VHS F - VHS OS - VHS B - VHS D Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness
Scr Ccr Smin Cmin hmin
M6 180 100 95 50 80
mm mm mm mm mm
M8 240 120 120 60 100
M10 250 150 145 75 120
Permissible loads - applications in concrete C20/25 Screws cl. 10.9 Screws A2 Threaded stud cl. 5.8 VHS OS
1 daN≃1 kg daN daN daN daN
180 140 105 35
250 220 160 75
400 380 280 100
Permissible loads - applications in solid brick compression resistance 18/20 N/mm2 Screws 8.8
M12 280 170 175 90 150
daN
100*
160*
280*
930 700 540
1 daN≃1 kg 390*
* Indicative values - For applications on solid bricks is not possible to show specific loading values because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.
• Always respect the installation parameters • In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load • The table shows the permissible loads for tension, shear and combined tension and shear loads 182
through-setting heavy duty anchors
Vorpa VHS Heavy duty anchor with European Technical Assesment for non cracked concrete
concrete
natural stone
solid brick
product code and technical data heavy duty anchors
VHS PF with 8.8 hexagonal head screw
Code
Description
Lt mm
Screw d x Lv mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
555 1558 564 1567 580 1586 587 1592 1593
VHS PF VHS PF VHS PF VHS PF VHS PF VHS PF VHS PF VHS PF VHS PF
70 80 100 120 80 100 120 140 160
M10x70 M10x80 M10x100 M10x120 M12x80 M12x100 M12x120 M12x140 M12x160
14 14 14 14 16 16 16 16 16
65 65 65 65 70 70 70 70 70
10 20 40 60 15 35 55 75 95
40 40 40 40 75 75 75 75 75
17 17 17 17 19 19 19 19 19
14/10-70 14/20-80 14/40-100 14/60-120 16/15-80 16/35-100 16/55-120 16/75-140 16/95-160
A2 Stainless Steel version on request
h1 = Min. hole depth Lt = Anchor length Lv = Screw length do = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length
Examples of applications
VHS PF Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness
Scr Ccr Smin Cmin hmin
VHS PF M10 250 150 145 75 120
mm mm mm mm mm
VHS PF M12 280 170 175 90 150
Permissible loads - applications in concrete C20/25 VHS PF
1 daN≃1 kg daN
600
• Always respect the installation parameters • In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load • The table shows the permissible loads for tension, shear and combined tension and shear loads 183
850
through-setting heavy duty anchors
Vorpa VTS Steel anchor
concrete
natural stone
solid brick
heavy duty anchors
products group
VTS with 8.8 hexagonal head screw
To fix • stairs • window and door frames • profiles • gates • railings
Suitable for • concrete • natural stone • solid brick
product information Characteristics • through steel anchor with slots on the body and on the expansion conical nut • smooth expansion • high setting quickness through the object to be fixed
Installation • through-setting anchor Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
installation sequence
Clean the hole before the installation
Code
Description
Lt mm
do mm
h1 mm
tfixmax mm
Tinst mm
Ch
8883 8884 8885 8886 8887 8888 8889 8890 8891 8892
VTS VTS VTS VTS VTS VTS VTS VTS VTS VTS
45 70 90 55 80 100 65 80 100 80
8 8 8 10 10 10 12 12 12 16
45 45 45 50 50 50 60 65 65 65
10 30 45 15 35 55 15 25 45 20
10 10 10 25 25 25 50 50 50 75
10 10 10 13 13 13 13 17 17 17
8/10-45 8/30-70 8/45-90 10/15-55 10/35-80 10/55-100 12/15-65 12/25-80 12/45-100 16/20-80
h1 = Min. hole depth Lt = Anchor length Lv = Screw length do = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
VTS Critical axial spacing Critical edge distance Minimum structural thickness
Scr Ccr hmin
VTS M6 120 60 100
mm mm mm
VTS M8 135 67,5 100
VTS M10 165/180 85/90 100
Permissible loads - applications in concrete C20/25 Screws 8.8
VTS M12 180/195 90/97,5 130 1 daN≃1 kg
90
daN
140
230/250
• Always respect the installation parameters • In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load • The table shows the permissible loads for tension, shear and combined tension and shear loads 184
255/280
through-setting heavy duty anchors
Vorpa VO Brass anchor
wood
concrete
natural stone
solid brick
products group Suitable for • wood • concrete • natural stone • solid brick
To fix • railings • profiles • stairs • wood columns
VO S with double threaded screw for wood column
product information Characteristics • brass anchor for metric screws • the version VO S is composed of a brass anchor and a double threaded screw for wood column • smooth expansion thanks to the slots on the body • special surface structure prevents it rotating in the hole • expansion carried out by screwing the accessory
Installation • pre-setting anchor Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
installation sequence
Anchor VO
Anchor VO S
Clean the hole before the installation
Examples of applications
185
heavy duty anchors
VO no accessories
through-setting heavy duty anchors
Vorpa VO Brass anchor
wood
concrete
natural stone
solid brick
heavy duty anchors
product code and technical data VO no accessories Code
50580 581 582 583 584 585 50587
Description
Lt mm
For screw mm
do mm
h1 mm
VO 4 VO 5 VO 6 VO 8 VO 10 VO 12 VO 16
16 22 24 30 35 40 45
M4 M5 M6 M8 M10 M12 M16
5 6,5 8 10 12 15 20
20 30 30 35 40 45 50
h1 = Min. hole depth Lt = Anchor length Lv = Screw length do = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
VO S with double threaded screw for wood column Code
408 409
Description
Lt mm
Screw d x LV mm
do mm
h1 mm
VO S 8/90 VO S 10/120
30 35
M8x90 M10x120
10 12
35 40
Examples of applications
VO - VO S Permissible loads - applications in concrete C20/25 VO
daN
VO M5
VO M6
VO M8
VO M10
VO M12
50
140
200
250
340
• Always respect the installation parameters • In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load • The table shows the permissible loads for tension, shear and combined tension and shear loads 186
VO M16 1 daN≃1 kg 450
through-setting heavy duty anchors
Vorpa TOP security anchor Steel anchor
concrete
natural stone
solid brick
products group
*
Suitable for • concrete • natural stone • solid brick
TOP AE with A2 stainless steel shear nut
To fix • window and door frames • gates • railings • iron bars • traffic signals • garden fittings
A2 INOX 304 *
product information Characteristics • through steel anchor composed of anti-rotation cold formed body and expansion conical nut with shear nut. • anti-rotation during the installation procedure • possibility of pre-setting applications and through-setting applications • smooth expansion thanks to the three sectors body • shear nut
Installation • through-setting anchor Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
installation sequence
Anchor TOP AF
Anchor TOP AE
Clean the hole before the installation
Examples of applications
187
heavy duty anchors
TOP AF with zincplated steel shear nut AF
through-setting heavy duty anchors
Vorpa TOP security anchor Steel anchor
concrete
natural stone
solid brick
product code and technical data heavy duty anchors
TOP AF security anchor TOP AF sleeve anchor is a through fixing, thus ensuring fast and simple installation. Ideal for many security applications in a wide variety of base materials. The unique AF drive permanent nut offers an accurate torque controlled security fixing which can be re-torqued if necessary. TOP AF ZINCATO with zincplated steel shear nut AF
AF DRIVER SOCKET AND AF PERMANENT NUT
Description
Lt mm
Screw d x Lb mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
7578 TOP AF 12/5-51 7562 TOP AF 12/25-71 7563 TOP AF 12/45-91
51 71 91
M8x55 M8x75 M8x95
12 12 12
55 55 55
5 25 45
15 15 15
AF M8 AF M8 AF M8
Code
Code
72589 72592 72590 72591
Description
Internal thread
AF M8 AF M10 DADO AF M8 DADO AF M10
Nut
TOP AF anchor
art. 72590 art. 72591
art. 7578/7562/7563 -
h1 = Min. hole depth Lt = Anchor length Lb = Stud length do = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
M8 M10
TOP AE security anchor Security anchors with shear nut for final fixing of windows, iron fences, gates, etc. Suitable for every compact building materials. Exceeding a torque of 19 Nm the hexagonal head takes off giving no chance to slip off the fixing. Hexagonal head and washer are made in A2 Stainless Steel.
TOP AE with A2 stainless steel shear nut
Code
Description
578 TOP AE 12/10-56 562 TOP AE 12/30-76 563 TOP AE 12/50-96
A2 INOX 304
Lt mm
Screw d x Lb mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
56 76 96
M8x55 M8x75 M8x100
12 12 12
55 55 55
10 30 50
* * *
15 15 15
* Approximate breaking torque at 19Nm
TOP security anchor Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness
Scr Ccr Smin Cmin hmin
TOP M8 135 75 90 70 135
mm mm mm mm mm
Permissible loads - applications in concrete C20/25 TOP AE 12 - M8 TOP AF 12 - M8
1 daN≃1 kg daN daN
400 400
• Always respect the installation parameters • In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load • The table shows the permissible loads for tension, shear and combined tension and shear loads 188
through-setting heavy duty anchors
Vorpa VHS security anchor Steel anchor
concrete
natural stone
solid brick
products group VHS AE with stud and A2 stainless steel shear nut
*
VHS Z with stud and A2 stainless steel shear nut
Suitable for • concrete • natural stone • solid brick
To fix • window and door frames • gates • railings • iron bars • traffic signals • garden fittings
VHS AF with stud and steel shear nut AF
*
VHS CX VHS CX INOX A2 with steel Torx bit screw
A2 INOX
304 *
product information Characteristics • through steel anchor with slots on the body and on the expansion conical nut completed of shear nut. • smooth expansion thanks to the slots on the body and on the expansion conical nut • high setting quickness through the object to be fixed • high performances • shear nut
Installation • through-setting anchor Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Clean the hole before the installation
installation sequence
Anchor VHS AF
Anchor VHS CX - VHS CX INOX A2
189
heavy duty anchors
*
through-setting heavy duty anchors
Vorpa VHS security anchor Steel anchor
concrete
natural stone
product code and technical data heavy duty anchors
VHS AF security anchor VHS AF sleeve anchor is a through fixing, thus ensuring fast and simple installation. Ideal for many security applications in a wide variety of base materials. The unique AF drive permanent nut offers an accurate torque controlled security fixing which can be re-torqued if necessary. Reduced hole diameter compared to TOP version. VHS AF with stud and steel shear nut AF Code
AF DRIVER SOCKET AND AF PERMANENT NUT
Description
Lt mm
Screw d x Lb mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
7517 VHS AF 10/5-50 7510 VHS AF 10/25-70 7512 VHS AF 10/55-100
50 70 100
M8x55 M8x75 M8x100
10 10 10
55 55 55
5 25 55
15 15 15
AF M8 AF M8 AF M8
Code
72589 72592 72590 72591
Description
Internal thread
AF M8 AF M10 DADO AF M8 DADO AF M10
Nut
TOP AF anchor
art. 72590 art. 72591
art. 7578/7562/7563 -
h1 = Min. hole depth Lt = Anchor length Lb = Stud length do = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
M8 M10
VHS CX-VHS CX INOX A2 security anchor Security anchors for final fixing of windows, iron fences, gates, etc. granting protection against burglary and thievery. Head screw is characterized by Torx bit T40. Zamak star must be hammered into Torx bit making the anchor impossible to remove. Reduced hole diameter compared to TOP version.
VHS CX with steel Torx bit screw Code
VHS CX INOX A2 with A2 stainless steel Torx bit screw
A2 INOX 304
Description
Lt mm
Screw d x Lv mm
do mm
h1 mm
tfix max mm
Tinst Nm
Torx bit
50517 VHS CX 10/15-60 50510 VHS CX 10/35-80 50511 VHS CX 10/55-100
60 80 100
M8x60 M8x80 M8x100
10 10 10
55 55 55
15 35 55
25 25 25
T40 T40 T40
60517 VHS CX A2 10/15-60 60510 VHS CX A2 10/35-80 60511 VHS CX A2 10/55-100
60 80 100
M8x60 M8x80 M8x100
10 10 10
55 55 55
15 35 55
25 25 25
T40 T40 T40
Examples of applications
190
solid brick
through-setting heavy duty anchors
Vorpa VHS security anchor Steel anchor
concrete
natural stone
solid brick
product code and technical data VHS Z security anchor
VHS AE with stud and A2 stainless steel shear nut Code
517 510 512
heavy duty anchors
Security anchors with shear nut for final fixing of windows, iron fences, gates, etc. Suitable for every compact building materials. Exceeding a torque of 19 Nm the hexagonal head takes off giving no chance to slip off the fixing. Hexagonal head and washer are made in A2 Stainless Steel. Reduced hole diameter compared to TOP version.
A2 INOX 304
Description
Lt mm
Screw d x Lb mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
VHS AE 10/10-55 VHS AE 10/30-75 VHS AE 10/60-105
55 75 105
M8x60 M8x75 M8x100
10 10 10
55 55 55
10 30 60
* * *
15 15 15
h1 = Min. hole depth Lt = Anchor length Lb = Stud length do = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
* Approximate breaking torque at 19Nm
VHS Z with stud and A2 stainless steel shear nut
A2 INOX 304
Code
Description
Lt mm
Screw d x Lb mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
2588 2510
VHS Z 10/18-65 VHS Z 10/38-85
65 85
M8x60 M8x80
10 10
55 55
18 38
* *
15 15
* Approximate breaking torque at 19Nm
installation sequence
Clean the hole before the installation VHS security anchor Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness
Scr Ccr Smin Cmin hmin
VHS M8 240 120 120 60 100
mm mm mm mm mm
Permissible loads - applications in concrete C20/25 VHS AF - VHS Z - VHS AE 10 - M8 VHS CX cl. 8.8 10 - M8 VHS CX INOX A2 10 - M8
1 daN≃1 kg daN daN daN
200 230 230
• Always respect the installation parameters • In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load • The table shows the permissible loads for tension, shear and combined tension and shear loads 191
through-setting heavy duty anchors
Vorpa VH AE security anchor Nylon plug
solid brick
perforated brick
heavy duty anchors
products group VH AE with stud and A2 stainless steel shear nut
Suitable for • solid brick • perforated brick
To fix • window and door frames • gates • railings • iron bars • traffic signals • garden fittings
A2 INOX 304
product information Characteristics • special permanent temper-proof fixings as protection against burglary and thievery • nylon plug with diagonal slots • anti-rotation system during the installation • possibility of pre-setting applications and through-setting applications • smooth expansion thanks to the slots on the body • shear nut • the exagonal head takes off giving no change to slip off the fixing.
Installation • through-setting anchor Suggestion for use • choose the right size of the anchor according to the load • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
installation sequence
Clean the hole before the installation Code
Description
588 VH AE 558 VH AE
12/5-70 12/25-95
Lt mm
Screw d x Lb mm
do mm
h1 mm
tfix max mm
Tinst Nm
Ch
70 70
M8x75 M8x95
12 12
75 75
5 25
* *
13 13
* Approximate breaking torque at 19Nm Examples of applications
h1 = Min. hole depth Lt = Anchor length Lb = Stud length do = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
VHS security anchor Permissible loads - applications in concrete C20/25 daN
150
• Always respect the installation parameters • In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load • The table shows the permissible loads for tension, shear and combined tension and shear loads 192
1 daN≃1 kg
heavy duty anchors
Vorpa SAFETY THREADED NUT Safety zincplated and A2 stainless steel threaded nuts products group e technical data
Anti-burglar nut with one-sided clamping system. With a torque of about 19 Nm, the hexagonal head detaches without giving the possibility of tampering and dissambly of the object
DTS P INOX A2 safety A2 stainless steel threaded nut with shear head and through hole Code
58999 59000 59001 59006
Description
DTS P DTS P DTS P DTS P
M M M M
6/13 8/17 10/19 12/19
DTS PZ safety zincplated threaded nut with shear head and through hole
A2 INOX 304
Internal thread
Hexagon size
Tinst Nm indicative
Code
M6 M8 M10 M12
13 17 19 19
15-25 30-40 75-85
59000Z 59001Z 59002Z
M8 M10
13 17
15-25 30-40
58996Z 58976Z
Description
Internal thread
Hexagon size
Tinst Nm indicative
DTS PZ M 8/17 DTS PZ M 10/19 DTS PZ M 12/22
M8 M10 M12
17 19 22
15-25 30-40 75-85
DTS PZ M 8/13 DTS PZ M 10/17
M8 M10
13 17
Reduced hexagonal size versionv
58996 58997
90840
DTS P M 8/13 DTS P M 10/17
90841
Ø
Ø
90842
90843
90840Z
DTS INOX A2 safety A2 stainless steel M8 threaded nut with shear head Code
90840 90841 90842 90843 4042 4049
Description
Internal thread
DTS SVASATO M8 DTS M8 DTS 8/12 M8 DTS 8/10 M8 RONDELLA A2 10x20x2 RONDELLA A2 12x22x2,5
Hexagon size
15 13 15 15
304
Tinst Nm indicative
Code
90840Z 90845Z 90842Z 90843Z
19 19 19 19
12 10
Ø
Ø
90842Z
90843Z
DTS Z safety zincplated M8 threaded nut with shear head
A2 INOX Ø
90841Z
Description
DTS Z SVASATO DTS Z DTS Z 8/12 DTS Z 8/10
THREADED NUT AF DRIVE The special design of the permanent AF nut once brought to tightening, guarantees the inviolability of the mechanical anchor AF DRIVER SOCKET AND AF PERMANENT NUT
Code
72589 72592 72590 72591
Description
AF M8 AF M 10 DADO AF M8 DADO AF M 10
Nut
VHS AF anchor
art. 72590 art. 72591
art. 5717/5710/5712
15-25 30-40
A mm
B mm
Internal thread
16,10 20,10
7,30 9,10
M8 M10
193
Internal thread
Hexagon size
M8 M8 M8 M8
15 15 15 15
Ø
12 10
Tinst Nm indicative
19 19 19 19
To fix • window and door frames • gates • railings • iron bars • traffic signals • garden fittings
heavy duty anchors
To fix • window and door frames • gates • railings • iron bars • traffic signals • garden fittings
SHEAR THREADED NUT
heavy duty anchors
Vorpa ACCESSORIES Fixing accessories products group heavy duty anchors
Fixing accessories • Zincplated washer/INOX A2 UNI 6592 DIN 125 A • Zincplated hexagonal nut/INOX A2 UNI 5588 • Zincplated hexagonal blind nut DIN 917 • Zincplated hexagonal threaded nut
Zincplated washer UNI 6592 DIN 125 A Code
Description
1505 1506 1507 1508 1509 1504 1499 1498 1497 1496 1495 1494
6 8 10 12 14 16 18 20 22 24 27 30
Internaldiameter mm
6 8 10 12 14 16 18 20 22 24 27 30
A2 SS washer UNI 6592 DIN 125 A External Thickness diameter mm mm
12 16 20 24 28 32 36 40 44 48 54 60
For screws mm
Code
Description
M6 M8 M10 M12 M14 M16 M18 M20 M22 M24 M27 M30
4040 4041 4042 4043 4044
6 A2 8 A2 10 A2 12 A2 16 A2
1,6 1,6 2 2,5 2,5 3 3 3 3 4 4 4
Zincplated hexagonal nut UNI 5588 Code
Description
1510 1511 1512 1513 1515 1514 1517 1519 1516 1518 1560 1561
M6 M8 M10 M12 M14 M16 M18 M20 M22 M24 M27 M30
90890S 90891S 90892S 90893S 90894 90895
Description
M6 M8 M10 M12 M14 M16
304
Internaldiameter mm
6 8 10 12 16
A2 SS washer UNI 5588
Internal thread mm
Hexagon size mm
M6 M8 M10 M12 M14 M16 M18 M20 M22 M24 M27 M30
10 13 17 19 22 24 27 27 32 36 41 46
Code
4050 4051 4052 4053 4054
Description
M6 A2 M8 A2 M10 A2 M12 A2 M16 A2
Zincplated hexagonal blind nut DIN 917 Code
A2 INOX External Thickness diameter mm mm
12 16 20 24 32
For screws mm
1,6 1,6 2 2,5 3
M6 M8 M10 M12 M16
A4 INOX 316
Internal thread mm
Hexagon size mm
M6 M8 M10 M12 M16
10 13 17 19 24
Zincplated hexagonal threaded nut
Internal thread mm
Hexagon size mm
M6 M8 M10 M12 M14 M16
10 13 17 19 22 24
Code
1365S 1365 1366S 1367S 1368S 1369S 1370S
194
Description
Internal thread mm
Length mm
Hexagon size mm
DF M6 x 20 DF M6 x 30 DF M8 x 30 DF M10 x 30 DF M12 x 40 DF M16 x 50 DF M20 x 60
M6 M6 M8 M10 M12 M16 M20
20 30 30 30 40 50 60
10 10 13 17 19 24 30
heavy duty anchors
Vorpa ACCESSORIES Fixing accessories product code and technical data
Pressed threaded eye
• DO NOT use the clamps in situations contrary to national safety or accident laws • DO NOT use the clamps in equipment intended for the transport or lifting of persons or animals • DO NOT exceed the loads indicated in the table • DO NOT ignore the instructions for use regarding the correct selection
*
Pressed threaded eye with nut and washer
A2 stainless steel pressed threaded eye
Pressed threaded eye Code
* 994 * * 995 * 996 * 997 * * 998 * 999
ØDxB thread x length
L thread
A length
E
M5x45 M5x50 M6x45 M6x55 M6x60 M8x57 M8x65 M10x68 M10x81 M10x101 M12x74 M12x98 M14x93 M16x100
40 48 40 50 55 52 60 60 73 93 66 90 85 95
60.7 65.7 64.6 74.6 79.6 78.6 86.7 94.1 107.1 127.1 106.3 130.3 127.1 145.3
52.7 57.7 54.6 64.6 69.6 67.4 75.4 80.6 93.6 113.6 89.5 113.5 109.4 122.1
G Ø min/max
15.3/16.7 15.3/16.7 18.3/19.7 18.3/19.7 18.3/19.7 21.8/23.2 21.8/23.2 26.0/28.0 26.0/28.0 26.0/28.0 32.5/34.5 32.5/34.5 34.5/36.5 44.8/47.2
F Ø min/max
S thickness min/max
8.05/8.55 3.20/3.80 8.05/8.55 3.20/3.80 9.75/10.25 3.90/4.50 9.75/10.25 3.90/4.50 9.75/10.25 3.90/4.50 10.75/11.25 4.90/5.50 11.55/12.05 4.90/5.50 14.25/14.75 6.15/6.85 14.25/14.75 6.15/6.85 14.25/14.75 6.15/6.85 16.75/17.25 8.15/8.85 16.75/17.25 8.15/8.85 17.75/18.25 8.30/9.10 22.70/23.30 12.10/12.90
Max load kg
L G
ØD
480 696
A
E
B
F S
1360 2020 2966
Racommended safety factor not less than 3
4290 5680
* on request
*
*
A2 stainless steel pressed threaded eye
A2 INOX
Code
ØDxB thread x length
L thread
A length
E
G Ø min/max
F Ø min/max
S thickness min/max
995i * * * * 996i * 997i * 998i
M6x55.5 M6x60.5 M6x65.5 M8x61.5 M8x66.5 M8x71.5 M10x67.0 M10x80.0 M12x73.5 M12x97.5
50 55 60 55 60 65 60 73 66 90
75.0 80.0 85.0 83.0 88.0 93.0 97.0 11.0 107.0 131.0
65.0 70.0 75.0 72.0 77.0 82.0 81.5 94.5 89.5 113.5
19.2/20.8 19.2/20.8 19.2/20.8 21.2/22.8 21.2/22.8 21.2/22.8 30.0/32.0 30.0/32.0 34.0/36.0 34.0/36.0
9.7/10.3 9.7/10.3 9.7/10.3 10.7/11.3 10.7/11.3 10.7/11.3 13.6/14.4 13.6/14.4 15.6/16.4 15.6/16.4
5.2/5.8 5.2/5.8 5.2/5.8 6.0/6.6 6.0/6.6 6.0/6.6 8.2/9.0 8.2/9.0 8.6/9.4 8.6/9.4
* on request
195
304
Max load kg
2100
2915 4540 7020
Racommended safety factor not less than 3
heavy duty anchors
• ideal for various applications • available also with nut and washer • suitable for each applications with chemical anchors and mechanical anchors
heavy duty anchors
Vorpa ACCESSORIES Fixing accessories
heavy duty anchors
product code and technical data • ideal for various applications • available also with nut and washer • suitable for each applications with chemical anchors and mechanical anchors
Pressed threaded hook
• DO NOT use the clamps in situations contrary to national safety or accident laws • DO NOT use the clamps in equipment intended for the transport or lifting of persons or animals • DO NOT exceed the loads indicated in the table • DO NOT ignore the instructions for use regarding the correct selection
*
Pressed threaded hook with nut and washer
A2 stainless steel pressed threaded hook
Pressed threaded hook Code
* 1070 * * 1010 * 1011 * * 1012 * 1013 *
ØD
M5 M5 M6 M6 M6 M8 M8 M8 M10 M10 M12 M12 M14
L thread
40 48 40 50 55 52 60 80 60 73 66 90 82
A length.
62.0 71.5 67.0 77.0 82.0 90.0 98.0 118.0 103.5 116.5 122.0 146.0 144.0
B
53.6 63.0 55.5 65.5 70.5 75.5 83.5 103.5 87.5 100.5 101.5 125.5 120.5
E
H
17.5 17.5 22.5 22.5 22.5 30.0 30.0 30.0 36.0 36.0 47.0 47.0 48.0
6.0 6.0 8.0 8.0 8.0 10.0 10.0 10.0 12.5 12.5 16.0 16.0 16.0
ØI Ø internal
Max load kg
H E
ØI
ØD L
7.5 7.5 9.5 9.5 9.5 11.0 11.0 11.0 14.0 14.0 18.0 18.0 17.0
173
A
B
241
387 547 1057
Racommended safety factor not less than 3
1342
* on request
Code
1010i * * 1011i * 1012i * 1013i
ØD
M6 M6 M8 M8 M10 M10 M12 M12
*
*
A2 stainless steel pressed threaded hook
A2 INOX 304
L thread
A length.
B
E
H
ØI Ø internal
50 55 55 60 60 73 66 90
77.0 82.0 93.0 98.0 103.5 116.5 122.0 146.0
65.5 70.5 78.5 83.5 87.5 100.5 101.5 125.5
22.5 22.5 30.0 30.0 36.0 36.0 47.0 47.0
8.0 8.0 10.0 10.0 12.5 12.5 16.0 16.0
9.5 9.5 11.0 11.0 14.0 14.0 18.0 18.0
* on request
GF threaded square hook Code
Description
1054
GF 10/95
Thread
Thread length mm
Ø hole mm without sleeve
M10
75
12
196
Max load kg
241 387 547 1057
Racommended safety factor not less than 3
heavy duty anchors
Vorpa WIRE ROPE CLIP Fixing accessories product code and technical data heavy duty anchors
To fix • radio systems cables • TV systems cables • tie rods for orchards • wire clotheslines • tensioning cables
Suitable for • wire ropes • cables • tie rods • ropes
Forged wire rope clip
Examples of installation
R
L Correct method of fitting Wire Rope Grips
E
F
C
I A
Incorrect method of fitting Wire Rope Grips
D B
Code
ØR mm
Ø R”
A mm
B mm
C mm
D mm
E mm
F mm
I mm
L mm
S mm
T mm
1520 1521 1522 1523 1524 * * * * * * * * * * * * *
2-3 4-5 6 8 10 11 12 14 16 18 20 22 24-25 26-28 30-32 36-38 42-45 48-50
1/8 3/16 1/4 5/16 3/8 7/16 1/2 9/16 5/8 11/16 3/4 7/8 1 1.1/8 1.1/4 1.1/2 1.3/4 2
21 25 30 33 38 40 43 46 53 59 60 64 70 80 92 95 115 116
12 18 19 20 22 22,5 25 27 31 33 34 34 40 43 45 51 58 59
9 9 10 10,5 11 13 13 17 18 20 22 23 24 30 34 39 43 46
M4 M5 M6 M6 M8 M8 M10 M10 M10 M12 M12 M12 M12 M14 M16 M16 M20 M20
5 5 6 6 6 6 6 7,5 8 8 9 9,5 10 12 14 16 16 16
12 14 19 22 22 23 30 30 32 38 38 42 46 50 70 75 83 83
9 11 15 16 19 21 23 25 28 30 33 37 40 42 49 57 70 70
20 25 33 35 43 43 55 55 63 78 78 80 88 97 130 135 158 178
1,25 2,46 4,24 4,24 10,2 10,2 20,11 20,11 20,11 34,43 34,43 34,43 34,43 54,77 85,14 85,14 167,2 167,2
3 3 4 4 4 4 5 5 5 5 5 6 6 7 8 8 10 10
S = Torque (with 0,10 safety factor included) T = Nr. clips to use
* on request
Examples of applications
197
heavy duty anchors
Vorpa WIRE ROP CLIP (italian ENEL-TELECOM standard) Galvanized forged clamp for ropes, cables and tie rods with serial number products group Suitable for • wire ropes • cables • rods
To fix • steel ropes • plant cables • rods • tension ropes and cables Caution Before starting to operate, perform the correspondence check functional and performance of the • ropes ENEL number 263202 clamp installed to confirm its suitability • ropes serial number TELECOM 02076-8
heavy duty anchors
Wire rope clip
product information and technical data
Installation mode It is advisable to apply the clamps at a distance from one another not less than 22 mm Tz
Correct installation
incorrect installation
CHECK
INTERVENTION FREQUENCY QUARTERLY ANNUAL X X X X X
Visual conditions Tightening torque Deformation Usury Conservation status
Selection criteria • the clips must be chosen according to the cable diameter • the clips must be used only for wire ropes • permissible temperature between -20°C e + 80°C • periodically check the functionality and efficiency of the clamp • the tightening torque must be transmitted with a tightening torque wrench • the clamp works efficiently until its geometric and physical characteristics and the applied tightening torque remain unchanged
Incorrect use
• In order not to compromise the safety and functionality of the product and not cause serious situations of danger for the safety of people or things • DO NOT use the clamps in situations contrary to national safety or accident laws • DO NOT combine the clamps with non-compliant accessories • modifying them in the structure or in the form • DO NOT use the clamps in equipment intended for the transport or lifting of persons or animals • DO NOT exceed the loads indicated in the table • DO NOT ignore the instructions for use regarding the correct selection or arrangement of the device to which the clamps will be connected with • DO NOT use the wire rope clips in tension with equipment that can change its own static configuration, the barycentre or the chemical state • DO NOT use the clips to join together two pieces of rope by welding it with metal parts or by intervening with welding fillings or using it as a mass for welding machines • DO NOT use the clips with plastic covered wire ropes, or for the construction of buttonholes to be used in lifting, do not use the clips connecting them to equipment of size, temperature point of coupling and shape not suitable for its characteristics, do not use them in situations of failure or incorrect maintenance Limitations DO NOT use the clamps • when the tightening torque is higher than indicated • as structural failures can occur on the U-bolt • when a smaller number of terminals is applied to how much indicated • at temperatures other than those indicated • when the force guideline does not extend along the main axis of the rope
Ø8-Ø6 Ø6-Ø4
C
B
2 3
D
A H
3
G
2
F E
Code
89002 ENEL 263202 Ø4-Ø6
89001 TELECOM 02076-8 Ø6-Ø8
A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) G (mm) H (mm) Peso (gr) Tinst (Nm) N Tz
M6 31 17 16,8 30 16 14 10 35 4,24 3 -
M8 42 25 20 37 22 20 13 70 10 3 240
1
1
N = min. numbers of clips to be installed Tinst = max tightening torque to be used
198
heavy duty anchors
Vorpa LIFTING EYEBOLT DIN 582-580 Fixing accessories product code and technical data
DIN 580
DIN 582
Caution Before starting to operate, perform the correspondence check functional and performance of the eyebolt installed to confirm its suitability DIN 580 D
P
PF
6 8 10 12 14 16 18 20 22 24 27 30 33 36 39 42 45 48
1 1,25 1,5 1,75 2 2 2,5 2,5 2,5 3 3 3,5 3,5 4 4 4,5 4,5 5
1,25 1,5 1,5 1,5 1,5 1,5 2 2 2 2 3 3 3 3 3
D
P
PF
6 8 10 12 14 16 18 20 22 24 27 30 33 36 39 42 45 48
1 1,25 1,5 1,75 2 2 2,5 2,5 2,5 3 3 3,5 3,5 4 4 4,5 4,5 5
1,25 1,5 1,5 1,5 1,5 1,5 2 2 2 2 3 3 3 3 3
A
B
36 36 36 36 45 45 54 53 63 62 63 62 72 71 72 71 81 80,5 90 90 96 97 108 109 108 109 126 128 144 147 144 147 166 168 166 168
C
E
G
H
K
J
L
WLL
WLL*
BL
13 13 17 20,5 27 27 30 30 35 36 39 45 45 54 63 63 68 68
6 6 8 10 12 12 14 14 14 18 19,5 22 22 26 30 30 35 35
20 20 25 30 35 35 40 40 45 50 55 65 65 75 85 85 100 100
4,6 6 7,7 9,4 11,3 13 15 16,5 18,5 19,6 22,6 25 28 30,3 33,3 35,6 38,6 41
8 8 10 12 14 14 16 16 18 20 21,5 24 24 28 32 32 38 38
10 10 12 14 16 16 19 19 21 24 25 28 28 32 38 38 46 46
20 20 25 30 35 35 40 40 45 50 53 60 60 70 80 80 90 90
0,075 0,14 0,23 0,34 0,50 0,70 0,93 1,20 1,45 1,80 2,70 3,20 3,20 4,60 5 6,30 7,60 8,60
0,05 0,10 0,17 0,24 0,35 0,50 0,65 0,86 1 1,29 1,80 2,30 2,80 3,30 3,50 4,50 5 6,10
6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6
C
E
G
H
L
WLL
WLL*
BL
20 20 25 30 35 35 40 40 45 50 55 65 65 75 85 85 100 100
8,5 8,5 10 11 13 13 16 16 18 20 21,5 24 24 28 32 32 38 38
10 10 12 14 16 16 19 19 21 24 25 28 28 32 38 38 46 46
8 8 10 12 14 14 16 16 18 20 21,5 24 24 28 32 32 38 38
20 20 25 30 35 35 40 40 45 50 53 60 60 70 80 80 90 90
0,075 0,14 0,23 0,34 0,50 0,70 0,93 1,20 1,45 1,80 2,70 3,20 3,20 4,60 5 6,30 7,60 8,60
0,05 0,10 0,17 0,24 0,35 0,50 0,65 0,86 1 1,29 1,85 2,30 2,80 3,30 3,50 4,50 5 6,10
6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6
DIN 582
BL WWT WWT* P
A
B
36 36 36 36 45 45 54 53 63 62 63 62 72 71 72 71 81 80,5 90 90 96 97 108 109 108 109 126 128 144 147 144 147 166 168 166 168
= Safety factor to be applied = Max load tonn. = Max load 45° tonn = Thread
199
heavy duty anchors
To fix • radio systems cables • TV systems cables • tie rods for orchards • wire clotheslines • tensioning cables
Suitable for • wire ropes • cables • rods
heavy duty anchors
Vorpa STEEL BUCKLE Fixing accessories
heavy duty anchors
product code and technical data
Eye and eye turn buckle
To fix • wire ropes • cables • rods • radio systems cables • TV systems cables • tie rods for orchards • wire clotheslines • tensioning cables
Hook and eye buckle
Hook and eye buckle
L
Code
D mm
A mm
B mm
C mm
E mm
F mm
G mm
L mm
Max load kg
Coeff.
1260 1261 1262 1263 * 1264 * * * * * * * * * * *
M5 M6 M8 M10 M11 M12 M14 M16 M18 M20 M22 M24 M27 M30 M33 M36 M39
35 44 52 62 68 70 85 90 98 105 118 130 135 135 148 158 170
8 11 11 14 15 16 18 23,5 25 26 28 28 31 31 36 42 49
16 19 22 28 33 33 36 48 51 57 60 65 71 71 88 94 104
9 10 13 14 18 18 20 22 27 27 28 30 49 56 56 55 58
49 59,5 71 90 90 91,5 113 132 135,5 156,5 160 179,5 188,5 188,5 201 230 238
7 8 10 12 15 15 17 19 20 20 23 25 31 31 34 44 44
80 90 110 125 120 140 170 190 200 220 240 260 300 310 310 295 330
25 45 75 115 140 150 210 340 450 650 900 1200 1400 1500 1750 2000 2250
4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
G
B C E D
A F
Coeff. = Safety factor to be applied * on request
Eye and eye turn buckle L
Code
D mm
A mm
B mm
C mm
E mm
F mm
L mm
Max load kg
Coeff.
1250 1251 1252 1253 * 1254 * * * * * * * * * * * * *
M5 M6 M8 M10 M11 M12 M14 M16 M18 M20 M22 M24 M27 M30 M33 M36 M39 M42 M45
35 44 52 62 68 70 85 90 98 105 118 130 135 135 148 158 170 170 170
8 11 11 14 15 16 18 23,5 25 26 28 28 31 31 36 38 42 50 50
16 19 22 28 33 33 36 48 51 57 60 65 71 71 88 94 104 110 110
9 10 13 14 18 18 20 22 27 27 28 30 49 56 56 55 58 66 66
49 59,5 71 90 90 91,5 113 132 135,5 156,5 160 179,5 188,5 188,5 201 230 238 245 245
80 90 110 125 120 140 170 190 200 220 240 260 300 310 310 295 330 340 340
100 150 300 470 580 650 800 1250 1500 1800 2250 2800 3500 4000 4500 5000 6000 7000 8000
4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
200
B C E D
A F
heavy duty anchors
Vorpa CABLE TIE FZ Fixing accessories products group
natural cable tie
black cable tie
product information Characteristics • high resistance to bases, oils, greases, oil derivatives • limited resistance to acids • not resistant to phenols and to chloride solvents • halogen-free resins • UV resistance (black color) • smooth rounded edges make them easier to be handled and safer to be installed • bent rounded tip allows easier insertion through the head of the cables ties • low friction coefficient of the material
Dati tecnici • material: Polyamide 6.6 • humidity absorption: 2,7% (50% relative humidity) • working temperature: - 40°C a + 85°C • tightening temperature: - 10°C a + 60°C • max admissable point:+ 110°C for short time • melting temperature: + 256°C • limit Oxygen Index (LOI): 27% • flammability rating: UL 94 class V2 • tested according to EN 50146
installation sequence
2.2 2.5 2.6
Insert the tip of the tie.
Tighten manually the tie till complete fixing of the cables.
Avoid sharp bending of the tie: it will not improve the fixing strength.
Cut the exceeding part of the tie, with a few mm of safety length.
00010 00011 00012 00013 00014 00015 00016
Description natural cable tie
FZ N FZ N FZ N FZ N FZ N FZ N FZ N
100/2,5 160/2,5 200/2,5 140/3,5 280/3,5 360/3,5 280/4,5
4.5 4.8
product information Code
3.5 2.6
Code
00001 00002 00003 00004 00005 00006 00007
Description black cable tie
FZ B FZ B FZ B FZ B FZ B FZ B FZ B
100/2,5 160/2,5 200/2,5 140/3,5 280/3,5 360/3,5 280/4,5
201
Ø bundle mm
Tensile strength Kg
21 40 52 35 80 103 79
8 8 8 13 13 13 22
7.8 9.0 12.5
heavy duty anchors
Suitable for • electrical installations • industrial wiring • automotive • panel buildings • special applications
3
Scaffolding anchors
scaffolding anchors
Vorpa TOP T Steel anchor for scaffolds standing on the ground
concrete
natural stone
solid brick
products group Suitable for • concrete • natural stone • solid brick
To fix • scaffolding standing on the ground
scaffolding anchors
TOP T eyebolt Ø50
Test report available
product information Characteristics • torque controlled expansion anchor made of galvanized steel composed of anti-rotation cold formed body, expansion conical nut and eyebolt Ø50mm • the eyebolt can be used several times thanks to the anchor spare part • the cap hole covering enables to cover off holes at the end of the work in a quick and simple way • eyebolt neck with flat slot to tight by wrench • anti-rotation during the installation procedure • three-part expansion sleeve allows even load distribution and small edge and axial spacing
Installation • to be mounted aligned the wall Suggestion for use • make sure the scaffold and eyebolt are well positioned each other • apply a proper safety factor according to the each situation • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Clean the hole before the installation
installation sequence
2) to re-use the eyebolt
1) installation procedure
Drill the masonry. Insert the anchor in the hole. Clean the hole by using proper Screw the eyebolt applying cleaning brushes and pump the correct torque and set the washer aligned to the wall
Installation completed
Examples of applications
204
Unscrew the eyebolt and pull it out
Close the hole with the proper cap
scaffolding anchors
Vorpa TOP T Steel anchor for scaffolds standing on the ground
concrete
natural stone
solid brick
product code and technical data
TOP T eyebolt Ø50
Code
do mm
Lt mm
h1 mm
Tinst mm
Øi mm
l mm
ch mm
TOP T 18/130 M12 TOP T 18/180 M12
18 18
130 180
140 190
75 75
50 50
100 100
22 22
Øi = Internal eyebolt diameter l = Axial spacing h1 = Min. hole depth Lt = Anchor length do = Hole diameter Tinst = Torque ch = Spanner
Accessories
code 713 Code
713 91294 1896
code 91294
code 1896
Description
do mm
Length mm
TOP 12 - Ø18 Washer Ø18 CFP cup hole covering
18
75
18
30
Sizes mm
C mm
18x45x3 22
Example of applications
TOP T Pull-out values in daN for applications on concrete C20/25
1 daN≃1 kg 4.500
ATTENTION: An appropriate safety factor ≥ 3 should be applied on these values • As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties • It is suggested to always make pull out tests before using the anchors • For any particular need please contact Vorpa technical department 205
scaffolding anchors
837 838
Description
scaffolding anchors
Vorpa AVZ T Steel anchor for scaffolds standing on the ground
concrete
natural stone
solid brick
products group Suitable for • concrete • natural stone • solid brick
To fix • scaffolding standing on the ground
scaffolding anchors
AVZ T eyebolt Ø50
product information Characteristics • torque controlled expansion anchor made of galvanized steel composed of anti-rotation cold formed body, expansion conical nut and eyebolt Ø50mm • the eyebolt can be used several times thanks to the anchor spare part • eyebolt neck with flat slot to tight by wrench • anti-rotation during the installation procedure
Installation • to be mounted aligned the wall Suggestion for use • make sure the scaffold and eyebolt are well positioned each other • apply a proper safety factor according to the each situation • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Clean the hole before the installation
installation sequence
2) to re-use the eyebolt
1) installation procedure
Drill the masonry. Insert the anchor in the hole. Clean the hole by using proper Screw the eyebolt applying cleaning brushes and pump the correct torque and set the washer aligned to the wall
Installation completed
Examples of applications
206
Unscrew the eyebolt and pull it out
Close the hole with the proper cap
scaffolding anchors
Vorpa AVZ T Steel anchor for scaffolds standing on the ground
concrete
natural stone
solid brick
product code and technical data
AVZ T eyebolt Ø50
Code
Description
do mm
Lt mm
h1 mm
Tinst mm
Øi mm
l mm
ch mm
1817
AVZ T 16/110 M10
16
110
120
50
50
100
22 scaffolding anchors
Øi = Internal eyebolt diameter l = Axial spacing h1 = Min. hole depth Lt = Anchor length do = Hole diameter Tinst = Torque ch = Spanner
Accessories
code 833 Code
833 91054
code 91054 Description
do mm
Length mm
AVZ M10-Ø16 Washer Ø16
16
60
Sizes mm
18x45x3
Example of applications
AVZ T Pull-out values in daN for applications on concrete C20/25
1 daN≃1 kg 1.600
ATTENTION: An appropriate safety factor ≥ 3 should be applied on these values • As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties • It is suggested to always make pull out tests before using the anchors • For any particular need please contact Vorpa technical department 207
scaffolding anchors
Vorpa TOP L Steel anchor for scaffolds standing on the ground
concrete
natural stone
solid brick
products group Suitable for • concrete • natural stone • solid brick
To fix • scaffolding standing on the ground
scaffolding anchors
TOP L eyebolt Ø50 and PVC washer
Ideal for applications on solid brick coated by heat insulating panels and rigid insulation materials
product information Characteristics • extralong torque controlled expansion anchor made of galvanized steel composed of anti-rotation cold formed body, expansion conical nut, eyebolt Ø50mm and PVC red washer • the eyebolt can be used several times thanks to the anchor spare part • eyebolt neck with flat slot to tight by wrench • anti-rotation during the installation procedure • three-part expansion sleeve allows even load distribution and small edge and axial spacing
Installation • to be mounted aligned the wall Suggestion for use • make sure the scaffold and eyebolt are well positioned each other • apply a proper safety factor according to the each situation • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Clean the hole before the installation
installation sequence 1) installation procedure
Drill the insulation panels with a cup with a centering tip
Drill the masonry with a Ø18 drill bit
Insert the anchor in the hole. Screw the eyebolt applying the correct torque and set the washer aligned to the wall. Installation completed
2) to re-use the eyebolt Unscrew the eyebolt and pull it out. Close the hole with the proper cap
208
scaffolding anchors
Vorpa TOP L Steel anchor for scaffolds standing on the ground
concrete
natural stone
solid brick
product code and technical data
TOP L Ø50 eyebolt Ø50 and PVC washer
Code
TOP L 18/130 M12 TOP L 18/180 M12
do panel mm
do mm
Lt mm
h1 mm
Tinst mm
Ø mm
l mm
ch mm
46 46
18 18
130 180
140 190
75 75
50 50
205 205
22 22
Øi = Internal eyebolt diameter l = Axial spacing h1 = Min. hole depth Lt = Anchor length do = Hole diameter Tinst = Torque ch = Spanner
Accessories
Code
713 91294 2870 91057
code 2870
art 91294
code 713 Description
do mm
Length mm
TOP 12 - Ø18 Washer Ø18 PVC washer Ø55 Spacer Ø18
18
75
code 91057 to be used with 59838 Sizes mm
18x45x3 22x55x3 18x54x1,5
Examples of applications
TOP L Pull-out values in daN for applications on concrete C20/25
1 daN≃1 kg 4.500
ATTENTION: An appropriate safety factor ≥ 3 should be applied on these values • As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties • It is suggested to always make pull out tests before using the anchors • For any particular need please contact Vorpa technical department 209
scaffolding anchors
59837 59838
Description
scaffolding anchors
Vorpa CVP Steel anchor for scaffolds standing on the ground
hollow brick
perforated brick
perforated cement
products group Suitable for • hollow brick • perforated brick • perforated cement
To fix • scaffolding standing on the ground
scaffolding anchors
CVP eyebolt Ø50
product information Characteristics • eyebolt anchor made of galvanized steel composed of eyebolt Ø50mm, CVX plastic perforated sleeve, CVD steel sleeve and steel washer Ø45mm for scaffolds standing on the ground • the eyebolt can be used several times thanks to the anchor spare part • eyebolt neck with flat slot to tight by wrench
Installation • to be mounted aligned the wall Suggestion for use • make sure the scaffold and eyebolt are well positioned each other • apply a proper safety factor according to the each situation • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Clean the hole before the installation
installation sequence
Drill the masonry
Clean the hole by using proper cleaning brushes and pump
Insert the plastic perforated sleeve into the hole. Fill the hole with chemical anchor and insert the steel sleeve. Screw the eyebolt and set the washer aligned to the wall. Installation completed
Examples of applications
210
scaffolding anchors
Vorpa CVP Steel anchor for scaffolds standing on the ground
hollow brick
perforated brick
perforated cement
product code and technical data
CVP eyebolt Ø50
Description
do wall mm
Lt mm
h1 mm
Øi mm
l mm
ch mm
808
CVP 20/95
20
85
95
50
100
22
Øi = Internal eyebolt diameter l = Axial spacing h1 = Min. hole depth Lt = Anchor length do = Hole diameter Tinst = Torque ch = spanner
Accessories
code 915
Code
915 1238 804 91332 1939
code 1238
code 91332
code 804
Description
do mm
Length mm
CVX plastic perforated sleeve CVD M12 steel sleeve Threaded bar Steel washer Eyebolt Ø50 - M12
20 16
85 80
code 1939
Sizes mm
M12x90 12x48x2,5
C mm
I mm
M12x100
• As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties • It is suggested to always make pull out tests before using the anchors • For any particular need please contact Vorpa technical department 211
scaffolding anchors
Code
scaffolding anchors
Vorpa VP R8 T Steel anchor for scaffolds standing on the ground
concrete
hollow brick
perforated brick
perforated cement
products group Suitable for • concrete • hollow brick • perforated brick • perforated cement
To fix • scaffolding standing on the ground
scaffolding anchors
VP R8 T eyebolt Ø50 and nylon plug
product information Characteristics • eyebolt anchor made of galvanized steel composed of anti-rotation nylon plug, double thread screw, eyebolt Ø50mm and steel washer • the eyebolt can be used several times thanks to the anchor spare part • eyebolt neck with flat slot to tight by wrench • anti-rotation during the installation procedure
Installation • to be mounted aligned the wall Suggestion for use • make sure the scaffold and eyebolt are well positioned each other • apply a proper safety factor according to the each situation • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Clean the hole before the installation
installation sequence 1) Installation procedure
Drill the masonry
Clean the hole by using proper cleaning brushes and pump
Insert the plastic plug into the hole
2) To re-use the eyebolt
Unscrew the eyebolt and pull it out
Screw the eyebolt and set the washer aligned to the wall. Installation completed
Screw both nuts M12 and tighten one nut against the other with a 19mm wrench Use the spanner counterclockwise to retrieve the screw and the nuts
212
scaffolding anchors
Vorpa VP R8 T Steel anchor for scaffolds standing on the ground
concrete
hollow brick
perforated brick
perforated cement
product code and technical data
VP R8 T eyebolt Ø50 and nylon plug
Code
849
Description
do mm
h1 mm
ØtxLt mm
Øi mm
l mm
ch mm
VP R8 T 16/140
16
165
12x140
50
100
22 scaffolding anchors
Øi Øt Øp l h1 Lt do ch
= Internal eyebolt diameter = Plug diameter = Double thread screw diameter = Axial spacing = Min. hole depth = Anchor length = Hole diameter = Spanner
Accessories
code 830 Code
830S 91332 92225 1939
code 91332
code 1939
code 92225
Description
Sizes mm
VP R8 T 16/140 Steel washer Double thread screw Eyebolt Ø50 - M12
16x140 12x48x2,5 12x180
I mm
M12x100
Examples of applications
VP R8 T Pull-out values in daN for applications on concrete C20/25
1 daN≃1 kg 820
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values • As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties • It is suggested to always make pull out tests before using the anchors • For any particular need please contact Vorpa technical department 213
scaffolding anchors
Vorpa VN P Steel anchor for scaffolds standing on the ground
concrete
solid brick
perforated brick
natural stone
products group Suitable for • concrete • solid brick • perforated brick • natural stone
To fix • scaffolding standing on the ground • tensioning ropes • chains
scaffolding anchors
VN P eyebolt Ø23
VN PX eyebolt Ø50
Test report available
product information Characteristics • galvanized steel welded eyebolt to be used with nylon plugs. suitable for scaffolds standing on the ground • the eyebolt can be used several times thanks to the anchor spare part • high load-bearing capacity is achieved by using it with the proper nylon fixing • the anchor grants safe and easy applications thanks to mark on the eyebolt stem enabling a right embedment depth during the anchoring
Installation • to be mounted aligned the wall Suggestion for use • make sure the scaffold and eyebolt are well positioned each other • apply a proper safety factor according to the each situation • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Clean the hole before the installation
installation sequence 1) Installation procedure
Drill the masonry
Clean the hole by using proper cleaning brushes and pump
Insert the nylon plug in the hole
Screw the eyebolt applying the correct torque
2) To re-use the eyebolt
Installation completed
Unscrew the eyebolt and pull it out
214
Close the hole with the proper cap
scaffolding anchors
Vorpa VN P Steel anchor for scaffolds standing on the ground
concrete
solid brick
perforated brick
natural stone
product code and technical data
VN P eyebolt Ø23
Description
do mm
h1 mm
hef mm
ØvxLo mm
hef+l mm
Øtxlt mm
Øi mm
Tinst mm
836 2837 2838 2834 2835 2836 2854 2855 2856
VN P VN P VN P VN P VN P VN P VN P VN P VN P
14 14 14 14 14 14 14 14 14
115 115 115 115 115 115 115 115 115
100 100 100 100 100 100 100 100 100
12x120 12x160 12x190 12x230 12x300 12x350 12x400 12x450 12x500
145 185 215 255 325 375 425 475 525
14x100 14x100 14x100 14x100 14x100 14x100 14x100 14x100 14x100
23 23 23 23 23 23 23 23 23
19 19 19 19 19 19 19 19 19
12/120 12/160 12/190 12/230 12/300 12/350 12/400 12/450 12/500
Øv = Eyebolt diameter Lo = Eyebolt length I = Axial spacing hef = Min. anchorage depth h1 = Min. hole depth Lt = Anchor length do = Hole diameter (use with nylon plug VN) Øt = Anchor diameter Tinst = Torque
VN PX eyebolt Ø50
Code
Description
do mm
h1 mm
hef mm
ØvxLo mm
hef+l mm
Øtxlt mm
Øi mm
Tinst mm
3836 3837 3838 3839 3840
VN PX 12/120 VN PX 12/160 VN PX 12/190 VN PX 12/230 VN PX 12/300
14 14 14 14 14
115 115 115 115 115
100 100 100 100 100
12x120 12x160 12x190 12x230 12x300
155 200 240 265 340
14x100 14x100 14x100 14x100 14x100
50 50 50 50 50
19 19 19 19 19
Accessories code 820 - 635R Code
Description
635R 820 2840
VN 14/75 VN 14/100 CFP cap hole covering
code 2840 do mm
Length mm
C mm
14 14 12/14
75 100 37
26
VN P - VN PX Pull-out values in daN for applications on concrete C20/25 using a nylong plug VN 14/100
1 daN≃1 kg
1.300
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values • As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties • It is suggested to always make pull out tests before using the anchors • For any particular need please contact Vorpa technical department 215
scaffolding anchors
Code
scaffolding anchors
Vorpa OS 8 Ø23 Steel anchor for scaffolds standing on the ground
concrete
solid brick
perforated brick
natural stone
products group Suitable for • concrete • solid brick • perforated brick • natural stone
To fix • scaffolding standing on the ground • tensioning ropes • chains
scaffolding anchors
OS eyebolt Ø23
product information Characteristics • galvanized steel welded eyebolt to be used with nylon plugs. suitable for scaffolds standing on the ground • the eyebolt can be used several times thanks to the anchor spare part • the anchor grants safe and easy applications thanks to mark on the eyebolt stem enabling a right embedment depth during the anchoring
Installation • to be mounted aligned the wall Suggestion for use • make sure the scaffold and eyebolt are well positioned each other • apply a proper safety factor according to the each situation • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Clean the hole before the installation
installation sequence 1) Installation procedure
Drill the masonry
Clean the hole by using proper cleaning brushes and pump
Insert the nylon plug in the hole
Screw the eyebolt applying the correct torque
2) To re-use the eyebolt
Installation completed
Unscrew the eyebolt and pull it out
216
Close the hole with the proper cap
scaffolding anchors
Vorpa OS 8 Ø23 Steel anchor for scaffolds standing on the ground
concrete
solid brick
perforated brick
natural stone
product code and technical data
OS eyebolt Ø23
Description
do mm
h1 mm
hef mm
ØvxLo mm
hef+l mm
Øtxlt mm
Øi mm
Tinst mm
1990 1991 1992
OS 8 Ø23 8/80 OS 8 Ø23 8/100 OS 8 Ø23 8/120
12 12 12
75 75 75
60 60 60
8x80 8x100 8x120
100 120 140
12x60 12x60 12x60
23 23 23
15 15 15
Accessories
code 634 Code
Description
634 2840
VN 12/60 CFP cap hole covering
Øv = Eyebolt diameter Lo = Eyebolt length I = Axial spacing hef = Min. anchorage depth h1 = Min. hole depth Lt = Anchor length do = Hole diameter (use with nylon plug VN) Øt = Anchor diameter Tinst = Torque
code 2840 do mm
Length mm
C mm
12 12/14
60 37
26
Examples of applications
OS 8 Ø23 Pull-out values in daN for applications on concrete C20/25 using a nylong plug VN 12/60
1 daN≃1 kg
500
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values • As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties • It is suggested to always make pull out tests before using the anchors • For any particular need please contact Vorpa technical department 217
scaffolding anchors
Code
scaffolding anchors
Vorpa VSP P Steel anchor for scaffolds standing on the ground
concrete
products group Suitable for • concrete
To fix • scaffolding standing on the ground • tensioning ropes • chains
scaffolding anchors
VSP P eyebolt Ø23
Test report available
product information Characteristics • galvanized steel welded eyebolt Ø23mm with VSP or VSX expansion body • the eyebolt can be used several times thanks to the anchor spare part • the special nylon washer avoids the seepage of water through the external hole • the anchor grants safe and easy applications thanks to mark on the eyebolt stem enabling a right embedment depth during the anchoring • smooth expansion thanks to the three cuts on the expansion body
Installation • to be mounted aligned the wall Suggestion for use • make sure the scaffold and eyebolt are well positioned each other • apply a proper safety factor according to the each situation • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Clean the hole before the installation
installation sequence
Examples of applications
218
scaffolding anchors
Vorpa VSP P Steel anchor for scaffolds standing on the ground
concrete
product code and technical data
VSP P eyebolt Ø23
Description
do mm
h1 mm
hef mm
Axial spacing hef+l
Øi mm
Expansion body M8
Tins mm
9882 9880 881
VSP P 12/130 VSP P 12/180 VSP P 12/215
12 12 12
80 95 85
80 80 80
130 180 215
23 23 23
12x45 12x55 12x45
25 25 25
Øi = Eyebolt internal diameter hef = Min. anchorage depth h1 = Min. hole depth do = Hole diameter tinst = Torque
Accessories
code 2833
code 3972
Code
Description
2833 3972 2840
Washer 12x32x4 VSP P 12 M8 CFP cap hole covering
code 840
do mm
Length mm
C mm
12 12/14
37
26
VSP P Pull-out values in daN for applications on concrete C20/25
1 daN≃1 kg 1.500
ATTENTION: An appropriate safety factor ≥ 3 should be applied on these values • As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties • It is suggested to always make pull out tests before using the anchors • For any particular need please contact Vorpa technical department • A too high torque moment during the installation may cause permanent deformations and even the breaking of the threaded part affecting the eyebolt resistance
219
scaffolding anchors
Code
scaffolding anchors
Vorpa AV P Steel anchor for scaffolds standing on the ground
concrete
natural stone
solid brick
products group Suitable for • concrete • solid brick • natural stone
To fix • scaffolding standing on the ground • tensioning ropes • chains
AV P eyebolt Ø23
scaffolding anchors
product information Characteristics • torque controlled expansion anchor AV composed of anti-rotation cold formed body, expansion conical nut, and eyebolt Ø23mm • the eyebolt can be used several times thanks to the anchor spare part • the anchor grants safe and easy applications
Installation • to be mounted aligned the wall Suggestion for use • make sure the scaffold and eyebolt are well positioned each other • apply a proper safety factor according to the each situation • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Clean the hole before the installation
installation sequence 1) Installation procedure
2) To re-use the eyebolt
Examples of applications
220
scaffolding anchors
Vorpa AV P Steel anchor for scaffolds standing on the ground
concrete
natural stone
solid brick
product code and technical data
AV P eyebolt Ø23
Code
do mm
Lt mm
h1 mm
Tinst mm
Øi mm
l mm
ch mm
AV P 16/75 AV P 16/100 AV P 16/115
16 16 16
75 100 115
85 110 125
25 25 25
23 23 23
35 35 35
17 17 17
h1 = Min. hole depth Lt = Anchor length do = Hole diameter Tinst = Torque Øi = Eyebolt internal diameter ch = spanner
Accessories
code 552 Code
552 91280zb 51153 51154 51155
code 91280zb
Description
do mm
Length mm
AV 10 - Ø16 Steel washer Ø10 Spacer code 11570 Spacer code 571 Spacer code 552
16
75
spacer Sizes mm
10x30x2,5 16x10x1,5 16x30x2 16x48x2
AV P AV P Critical axial spacing Critical edge distance
Scr Ccr
mm mm
220 120
Pull-out values in daN for applications on concrete C20/25
1 daN≃1 kg 600*
* bending moment
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values • As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties • It is suggested to always make pull out tests before using the anchors • For any particular need please contact Vorpa technical department • A too high torque moment during the installation may cause permanent deformations and even the breaking of the threaded part affecting the eyebolt resistance
221
scaffolding anchors
11570 571 572
Description
scaffolding anchors
Vorpa Scaffolding anchoring extension Scaffolding anchoring extension for eyebolt products group
Code 3890-1897-1890S
To fix • scaffolding standing on the ground
Ø48
scaffolding anchors
Code 1891-1898-1891S Test report available Ø20 ± 1 mm
product information and technical data Characteristics • anchoring extension system for scaffolding standing on the ground • excellent grip on the scaffolding • electrolytic galvanizing with protection cap Suggestion for use • make sure the scaffold and eyebolt are well positioned each other
Examples of application extension Ø48
One protection cap is included for each scaffolding anchoring extension Examples of application extension Ø20
Ø
Code
3890 1897 1890S 1895
Code
1891 1898 1891S 1895
Description
Anchoring extension Ø48 L.45 cm Anchoring extension Ø48 L.30 cm Anchoring extension Ø48 L.100 cm TP 50 protection cap
Description
Anchoring extension Ø20 L.48 cm Anchoring extension Ø20 L.30 cm Anchoring extension Ø20 L.100 cm TP 50 protection cap
A mm
B mm
Ø mm
450 300 1000
170 170 170
Ø48 Ø48 Ø48 Ø48
A mm
B mm
Ø mm
C mm
480 300 1000
90 90 90
Ø20 Ø20 Ø20 Ø48
53 53 53
Examples of applications
222
A
B
Ø
B A C Ø
scaffolding anchors
Vorpa Scaffold Kit tester 2000 - 25 kN Scaffold tester products group Suitable for • pull out tests on scaffolding anchors and chemical anchors
Analogic gauge
Digital gauge
Case
product information and technical data Tester characteristics • tester with fixed gauge calibrated to 25 kN with maximum load indicator • load spreading bridge feet granting the proper positioning in every situation • compact and pratical, it grants safety and reliability • strong rectangular stand • maximum tensile load 25 kN • calibration Certificate • supplied in a plastic carrying case • weight 10 kg, dimension cm 55x39x14
Gauge characteristics • indication of pull-out load • calibrated in kn • traceable calibration certificate supplied with each guage • protective rubber cover • impact resistant glass • protection against sudden load relief (i.e. sudden failure of fixing) • digital gauge compatible with Bluetooth Digital System
Kit content * • 25 kN gauge • load spreading bridge with level bubbles • hex legs with leg extension adjustment • swivelfFeet • M12 locking adaptor • M12 ringbolt adaptor clevis • bolt Test Adaptor M6-M8-M10-M12 • M16 stud bolt • operating instructions • calibration certificate • oil bottle
Code
Description
6500D Tester 25 kN with analogic gauge 6499 Tester 25 kN with digital gauge 6517 Analogic gauge 25 kN 6518 Digital gauge 25 kN
High quality professional tool Pull out tests on scaffolding anchors
Examples of applications
223
scaffolding anchors
Tester
scaffolding anchors
Vorpa Scaffold Kit tester 2000 - 25 kN Scaffold tester product information
scaffolding anchors
The Bluetooth Digital system on digital gauge allows on-site pull tests to be automatically recorded and compiled into a digital report using the Bluetooth Digital App on a mobile phone or tablet device. These reports can be sent directly to clients or managers and are stored in the cloud to be accessed remotely anywhere on a browser in a users own company dashboard. (Requires separate subscription charge)
Tester with digital gauge
Bluetooth Digital System Examples of applications
224
scaffolding anchors
Vorpa Scaffold Kit tester 2050 - 50 kN Scaffold tester products group Suitable for • pull out tests on scaffolding anchors and chemical anchors
Analogic gauge
Digital gauge
Case
product information and technical data Tester characteristics • medium duty tester 50kN tension for pull out tests on scaffolding anchors and chemical anchor • increased gauge scope - The new tester 50 kN tester features a 50kN(5 ton) analogue gauge as standard • digital gauges are also available • turning handle - A new turning handle has been developed to accomodate the larger load. It offers a larger handle for ease of use and features an integrated M24 opearating nut for use with a ratchet spanner for operation in confined spaces • reinforced load spreading bridge - To sustain a 50kN load a new robust bridge design has been made which is denser in profile • it features three telescopic legs with pin arrangement in six positions and 30mm of fine adjustment at the base
Gauge characteristics • indication of pull-out load • calibrated in kn • traceable calibration certificate supplied with each guage • protective rubber cover • impact resistant glass • protection against sudden load relief (i.e. sudden failure of fixing) • digital gauge compatible with Bluetooth Digital System
Code
Kit content * • 50 kN gauge - load spreading bridge • leg extension adjustment • analogic gauge • swivel feet • M12 Locking Adaptor • nr.6 bolt test adaptor M4-M12 • nr.5 threaded stud adaptors • operating instructions - calibration certificate • oil bottle • robust carry case with grab handle
Description
6511 Tester 50 kN with analogic gauge 6498 Tester 50 kN with digital gauge 6515 Analogic gauge 50 kN 6516 Digital gauge 50 kN
High quality professional tool Pull out tests on scaffolding anchors Ringbolt adaptor clevis available on request
Examples of applications
225
scaffolding anchors
Tester
scaffolding anchors
Vorpa Scaffold Kit tester 2050 - 50 kN Scaffold tester product information
scaffolding anchors
The Bluetooth Digital system on digital gauge allows on-site pull tests to be automatically recorded and compiled into a digital report using the Bluetooth Digital App on a mobile phone or tablet device. These reports can be sent directly to clients or managers and are stored in the cloud to be accessed remotely anywhere on a browser in a users own company dashboard. (Requires separate subscription charge)
Tester with digital gauge
Bluetooth Digital System Examples of applications
226
scaffolding anchors
Vorpa Scaffold tester 145 kN Scaffold tester products group
Digital gauge
Carry case with wheels
product information and technical data Tester characteristics • heavy duty tester 145 kN tension for pull out tests on heavy duty anchors and chemical anchors • 3 adjustable legs with swivel feet • load spreading bridge with 10mm eye hook • 22mm ratchet spanner • lightweight triangular shape aluminium load spreading bridge • 0-145kN DUal Scale Digital Gauge, compatible with Bluetooth Digital System • 5 threaded adaptors (M12, M16, M20, M24, M30) • operating nut • robust carry case with telescopic handle and wheels • operating instructions - calibration certificate
Code
Description
6502 Carrying case 145 kN with wheels
High quality professional tool Pull out tests on scaffolding anchors
Carry case content
Examples of applications
227
scaffolding anchors
Tester
Suitable for • proof and failure load testing of most fixing types • high load expanding and resin anchors • cast in sockets and channel • holding down bolts for stanchion base plates • base plate fixings for column lighting • anchorage for crash barrier and safety fences • anchorage for stadium crush barriers • bridge parapet anchors
scaffolding anchors
Vorpa Scaffold tester 145 kN Scaffold tester product information
scaffolding anchors
The Bluetooth Digital system on digital gauge allows on-site pull tests to be automatically recorded and compiled into a digital report using the Bluetooth Digital App on a mobile phone or tablet device. These reports can be sent directly to clients or managers and are stored in the cloud to be accessed remotely anywhere on a browser in a users own company dashboard. (Requires separate subscription charge)
Bluetooth Digital System
Tester 145 kN components
228
scaffolding anchors
Vorpa Safety hook ACR Steel anchor for anti-fall nets
concrete
solid brick
natural stone
boards and iron beams panels IPE structures
products group
ACR TOP with TOP anchor
ACR VHS with VHS anchor
To fix • anti-fall nets • ropes
Suitable for • concrete • solid brick • natural stone • boards and panels • prestressed concrete plates with honeycomb core • iron beams • IPE structures
scaffolding anchors
ACR VA with VA anchor
ACR hook
A2 INOX 304
Test report available
product information Characteristics • system composed of a steel curly hook and steel anchor for ropes and anti-falling nets on pillars, beams and solid walls • possibility to insert and unfasten the fall prevention cable on the hook once made the fixing • the hook is recovered once the work is finished
Installation • to be mounted aligned the wall Suggestion for use • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
installation sequence ACR TOP anchor on solid brick
ACR VA anchor on thin solid brick
Revisione scheda 03-2021
Clean the hole before the installation
229
scaffolding anchors
Vorpa Safety hook ACR Steel anchor for anti-fall nets
concrete
solid brick
natural stone
boards and iron beams panels IPE structures
product code and technical data
scaffolding anchors
ACR TOP with TOP anchor
Code
Description
9340 9326
ACR TOP Ø18 M12 ACR TOP Ø14 M10
do Ø mm
Lt mm
h1 l mm mm
18 14
75 60
85 70
Thread mm
Øg mm
C mm
Øi mm
Lg mm
Tinst Nm
M12 M10
10,7 9
13 15
26 16
150 130
50 30
50 45
C = passage of the rope
Lt = Anchor length h1 = Min. hole depth do = Hole diameter Øg = Stem of the hook Øi = Passage of the rope Lg = Total length of the hook l = Axial spacing Tinst = Torque
ACR VHS with VHS anchor
Code
Description
9324 9325
ACR VHS Ø10 M8 ACR VHS Ø12 M10
do Ø mm
Lt mm
h1 l mm mm
10 12
70 63
55 73
Thread mm
Øg mm
C mm
Øi mm
Lg mm
Tinst Nm
M8 M10
7 9
17 15
16 16
135 130
25 40
50 45
C
h1
C = passage of the rope
C
ACR VA with VA anchor Lg
Art.
9341 9344
Description
ACR VA Ø15 M12 ACR VA Ø8 M6
do Ø mm
Lt mm
h1 l mm mm
15 8
50 25
55 30
45 40
Thread mm
Øg mm
C mm
Øi mm
Lg mm
Tinst Nm
M12 M8
10,7 5
13 7
26 13
110 60
35 4
C = passage of the rope
C
h1
Examples of applications
230
scaffolding anchors
Vorpa Safety hook ACR Steel anchor for anti-fall nets
concrete
solid brick
natural stone
boards and iron beams panels IPE structures
product code and technical data
ACR hook T fix
Description
9338 9339 9343 9345 9346
ACR M6 gancio zincato ACR M8 gancio zincato ACR M10 gancio zincato ACR M12x110 gancio zincato ACR M12x150 gancio zincato
L. Thread mm
I mm
Thread mm
Øg mm
C mm
Øi mm
Lg mm
30 67 67 37 83
40 50 45 45 45
M6 M8 M10 M12 M12
5 7 9 10,7 10,7
7 17 15 13 13
13 16 16 26 26
60 135 130 110 150
9 9
15 15
16 16
90 130
ACR SS A2 hook
53340 53341
ACR M10x90 gancio INOX A2 ACR M10x130 gancio INOX A2
45 45
35 67
M10 M10
C h1
do Øg Øi Lg l
= Hole diameter = Stem of the hook = Passage of the rope = Total length of the hook = Axial spacing
C = passage of the rope
Accessories
TOP Code
Description
VA
VHS
do mm
Lt mm
h1 mm
For screws Ø mm
713 712
TOP 12 Ø18 TOP 10 Ø14
18 14
593 590
VA 12 Ø15 VA 6 Ø8
15 8
50 25
55 30
M12 M6
VHS 10 Ø12 VHS 8 Ø10
12 10
60 70
55 73
M10 M8
51180 51182
75 60
85 70
M12 M10
ACR TOP - ACR VHS - ACR VA - ACR HOOK Determination of the resistance at the safety hook on concrete C20/25
1 daN≃1 kg
ACR TOP Ø18-M12 - ACR VA Ø15-M12 ACR TOP Ø14-M10 - ACR VHS Ø12-M10 ACR VHS Ø10-M8 ACR VA Ø8-M6
1.100 daN 900 daN 440 daN 200 daN
ATTENTION: An appropriate safety factor ≥ 2,5 should be applied on these values
231
scaffolding anchors
Code
scaffolding anchors
Vorpa AC M12 hook- AC Ø10 wood hook Steel anchor for anti-fall nets
concrete
solid brick
natural stone
boards and panels
products group
*
AC TOP with TOP M12 Ø18 anchor
Suitable for • concrete • solid brick • natural stone • boards and panels • glulam GL24h
To fix • anti-fall nets • ropes
scaffolding anchors
AC VA with VA M12 Ø15 anchor
* AC M12 hook
*
AC LEGNO hook with wood screw
ETAG 001-02 for non cracked concrete
Test report n° 327950 According to EN 1263
*
Test report n° 332232 According to EN 1263
* Test report available
product information Characteristics • safety hook with an innovative concept. The particular fold given to the hook ensures closure of the same, once the load of fall on the network it reaches the value of 700 daN on concrete and 450 daN on laminated wood • possibility to insert and unfasten the fall prevention cable on the hook once made the fixing • the hook is recovered once the work is finished • high loadability thanks to the adaptation of the eyelet to the anchor • wide selection of expanding bodies • wide range of assortment of hooks and anchors
Installation • to be mounted aligned the wall Suggestion for use • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Examples of applications
232
glulam GL24h
scaffolding anchors
Vorpa AC M12 hook Steel anchor for anti-fall nets
concrete
solid brick
natural stone
boards and panels
installation sequence Clean the hole before the installation
AC TOP anchor on solid brick
AC VA anchor on thin solid brick
scaffolding anchors
product code and technical data
*
AC TOP * with TOP M12 Ø18 anchor
ETAG 001-02 for non cracked concrete
B
Code
* 9315
Description
Lt mm
do mm
h1 mm
I mm
Thread mm
A B C mm
Tinst mm
AC TOP Ø18
75
18
85
60
M12
26 - 160 - 13
50
A
d C
C = passage of the rope h1
AC VA with VA M12 Ø15 anchor
B
A
Code
Description
Lt mm
do mm
h1 mm
I mm
Thread mm
A B C mm
Tinst mm
* 9317
AC VA Ø15
50
15
55
55
M12
26 - 140 - 13
35
C = passage of the rope
*
Test report n° 327950 According to EN 1263
Accessories
Code
713 712 593 8593 299
TOP Description
VA
VA F
Lt mm
do mm
h1 mm
For screws Ø mm
85 70
M12 M10
VA 12 Ø15 50 VA F 12 Ø15 50 VA IMPACTING TOOL
15 15
55 55
M12 M12
TOP 12 Ø18 TOP 10 Ø14
75 60
18 14
h1
Lt = Anchor length h1 = Min. hole depth do = Hole diameter l = Axial spacing Tinst = Torque A = Internal diameter of the hook B = Total length of the hook C = Passage of the rope
Test report available
*
C
233
scaffolding anchors
Vorpa Gancio AC M12 Steel anchor for anti-fall nets
boards and panels
product code and technical data
AC M12 hook B T fix A
Code
scaffolding anchors
* 9334
Description
AC M12
Thread mm
Thread length mm
I mm
h1 mm
Tfix max mm
A B C mm
M12
65
55
55
35
26 - 140 - 13 C = passage of the rope
*
C
h1
Lt = Anchor length h1 = Min. hole depth do = Hole diameter l = Axial spacing Tinst = Torque A = Internal diameter of the hook B = Total length of the hook C = Passage of the rope
Test report n° 327950 According to EN 1263 Test report available
Examples of applications
AC TOP 12 - AC VA 12 Determination of the resistance at the safety hook opening on concrete C20/25
1 daN≃1 kg
720 Notice: • the hook is closed at the indicated load (1) • the complete opening of the hook is determined at the maximum load of 1500 daN (2)
1) Behavior of the hook with pull-out up to 720 daN
2) Behavior of the hook with pull-out 1500 daN
234
scaffolding anchors
Vorpa AC legno Ø10 Steel anchor for anti-fall nets
glulam GL24h
product code and technical data ØD
AC LEGNO hook with wood screw
hmin B A do2 do1
Code
* 9322
Description
AC LEGNO Ø10x160
hnom mm
do1 x h1 Øxmm
do2 x h2 Øxmm
hmin mm
L.Thread mm
ØD mm
A B C mm
70
Ø7x70
Ø10x15
80
45
10
22 - 160 - 13
hnom
do1 x h1 = Pre-hole diameter x length do2 x h2 = Second pre-hole diameter x length hmin = Minimum thickness in the wood/beam hnom = Minimum embedment in the beam L.Thread = Thread length ØD = Stem of the hook A = Internal diameter of the hook B = Total length of the hook C = Passage of the rope
Test report n° 332232 According to EN 1263 Test report available
installation sequence AC legno Ø10 on wooden material 70 mm
15 mm
Ø7
Pre hole with drill Ø7
Ø10
Pre hole with drill Ø10
Thighten up to the dark
Insert the cable into the hook
Examples of applications
AC LEGNO Ø10 Determination of the resistance at the safety hook on laminated wood GL 24h
1 daN≃1 kg
700 ATTENTION: An appropriate safety factor ≥ 3 should be applied on these values • It is suggested to always make pull out tests before using the anchors 235
scaffolding anchors
C = passage of the rope
*
C
h2 h1
scaffolding anchors
Vorpa Gancio AC M12 - AC legno Ø10 Steel anchor for anti-fall nets
concrete
solid brick
natural stone
boards and panels
glulam GL24h
installation sequence
scaffolding anchors
Correct sequence
1) Standing in front of the hook, grab the net with both hands and place it under the hook opening
2) The part of the network, held by the right hand, must enter the open hook on the left
3) Hold the net with both hands pulling the ends to facilitate the move into the hook
4) The network has entered into the hook. proceed to the next hook
5) The network is entered correctly into the support hooks
Wrong sequence
NO
NO
1) The network is placed in front of the hook opening. NO
2) The network is placed behind the opening of the hook. NO
236
scaffolding anchors
Vorpa BEAM CLAMP Steel clamp for anti-fall nets
iron beams IPE structures
products group Suitable for • iron beams • IPE structures • metal carpentry
steel clamp
To fix • threaded accessories M8/M10/ M12 • tensioning ropes • fall protection nets • industrial plant engineering • conducting installations • plumbing and drains
Code
89004 9335 9336
Description
A mm
B mm
C mm
D mm
E mm
F mm
G mm
H mm
Max load anchor point kg
Certification
Morsetto M 8 Morsetto M10 Morsetto M12
21 23 35
19 21 23,5
35 42 54
M8 M10 M12
35 41 48
M8 M10 M10
18 20 26
38 44 58
120 250 350
Vds - UL VdS - UL - FM VdS - UL - FM
Steel clamp with through threaded hole and hedgehog safety hook M10
Steel clamp with through threaded hole and M12 safety hook
Examples of applications
237
scaffolding anchors
product code and technical data
scaffolding anchors
Vorpa AV GR Steel anchor for ropes and chains
concrete
natural stone
solid brick
products group To fix • ropes • chains
Suitable for • concrete • natural stone • solid brick
Tensioning ropes and chains
AV GR
scaffolding anchors
product code and technical data Characteristics • torque controlled expansion anchor AV GR composed of antirotation cold formed body, expansion conical nut, and steel hook for tensioning ropes and chains • the eyebolt can be used several times thanks to the anchor spare part • the anchor grants safe and easy applications • various sizes of the hook available Code
315 318 316
Installation • to be mounted aligned the wall Suggestion for use • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Description
do mm
Lt mm
h1 mm
l mm
Øg mm
Øi mm
Lg mm
Tinst Nm
AV GR M10 Ø16/45-135 AV GR M10 Ø16/75-162 AV GR M10 Ø16/125-212
16 16 16
65 65 65
75 75 75
45 75 125
9 9 9
15 15 15
135 162 212
30 30 30 h1
Lt = Anchor length h1 = Min. hole depth do = Hole diameter Øg = Stem of the hook Øi = Passage of the rope Lg = Total length of the hook I = Axial spacing Tinst = Torque
Clean the hole before the installation
installation sequence
AV GR Pull-out values in daN for applications on concrete C20/25
1 daN≃1 kg
Pull-out and shear
150*
* bending moment
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values • As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties • It is suggested to always make pull out tests before using the anchors 238
scaffolding anchors
Vorpa VT Steel anchor for ropes and chains
concrete
solid brick
perforated brick
products group To fix • ropes • chains
Suitable for • concrete • solid brick • perforated brick
Tensioning ropes and chains
VT with nylon plug
Characteristics • eyebolt anchor made of galvanized steel composed of oval eyebolt, double nylon plug and steel washer Ø60mm for tensioning ropes and chains • the eyebolt can be used several times thanks to the anchor spare part • anti-rotation double nylon plug
Installation • to be mounted aligned the wall Suggestion for use • apply a proper safety factor according to the each situation • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Italian Standard ENEL 278171 Code
301
Description
do mm
Lt mm
h1 mm
l mm
AxB mm
Tinst Nm
VT
18
140
150
65
33 x 70
60
18/140 M12
h1
Lt = Anchor length h1 = Min. hole depth do = Hole diameter Tinst = Torque I = Axial spacing
Clean the hole before the installation
installation sequence
VT Critical axial spacing Critical edge distance Minimum thickness member
Scr,N Ccr,N hmin
VT 230 120 250
mm mm mm
Pull-out values in daN for applications on concrete C20/25
1 daN≃1 kg 2.100 3.500
Pull-out Shear/flexural strength
ATTENTION: An appropriate safety factor ≥ 3 should be applied on these values • As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties • It is suggested to always make pull out tests before using the anchors 239
scaffolding anchors
product code and technical data
scaffolding anchors
Vorpa VT L Steel anchor for ropes and chains
concrete
solid brick
perforated brick
products group To fix • ropes • chains
Suitable for • concrete • solid brick • perforated brick
scaffolding anchors
Ideal for applications on perforated brick coated by heat insulating panels and rigid insulation materials
Tensioning ropes and chains
VT L with nylon plug and PVC washer
product information Characteristics • extralong eyebolt anchor made of galvanized steel composed of oval eyebolt, double nylon plug, steel washer Ø60mm and PVC red washer for tensioning ropes and chains on perforated brick coated by heat insulating panels and rigid insulation materials • the eyebolt can be used several times thanks to the anchor spare part • anti-rotation double nylon plug
Installation • to be mounted aligned the wall Suggestion for use • make sure the scaffold and eyebolt are well positioned each other • apply a proper safety factor according to the each situation • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Clean the hole before the installation
installation sequence
Drill the insulation panels with a cup with a centering tip
Drill the masonry with a Ø18 drill bit
Insert the anchor in the hole and screw the eyebolt
Set the washer aligned to the wall. Installation completed
Fill the hole in the insulation panel with expansion foam
Examples of applications
240
Clean the hole by using proper cleaning brushes and pump
scaffolding anchors
Vorpa VT L Steel anchor for ropes and chains
concrete
solid brick
perforated brick
product code and technical data
VT L Ideal for applications on perforated brick coated by with nylon plug heat insulating panels and rigid insulation materials and PVC washer
Code
Description
3301
VT L 18/140 M12
do panel Ø mm
do wall Ø mm
Lt mm
h1 mm
P mm
Tinst mm
AxB mm
l mm
60
18
140
150
150 + panel thickness
60
33 x 70
180 scaffolding anchors
Lt = Anchor length h1 = Min. hole depth do = Hole diameter Tinst = Torque I = Axial spacing P = Total length of the hole
Examples of applications
VT L Pull-out values in daN for applications on concrete C20/25 2.100 Bending moment in daN for applications on concrete C20/25
1 daN≃1 kg
1 daN≃1 kg
300 kg bending = permanent arrow 0,4 mm 550 kg bending = permanent arrow 18 mm
ATTENTION: An appropriate safety factor ≥ 3 should be applied on these values • As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties • It is suggested to always make pull out tests before using the anchors 241
scaffolding anchors
Vorpa TOP VT Steel anchor for ropes and chains
concrete
natural stone
solid brick
products group To fix • ropes • chains
Suitable for • concrete • natural stone • solid brick TOP VT with steel anchor
Tensioning ropes and chains
scaffolding anchors
product code and technical data Caratteristiche
• torque controlled expansion anchor made of galvanized steel composed of anti-rotation cold formed body, expansion conical nut and oval eyebolt for tensioning ropes and chains • the eyebolt can be used several times thanks to the anchor spare part • anti-rotation during the installation procedure • three-part expansion sleeve allows even load distribution and small edge and axial spacing
Installation • to be mounted aligned the wall Suggestion for use • apply a proper safety factor according to the each situation • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Italian Standard ENEL 278170 Code
302
Description
TOP VT 18/90 M12
do Ø mm
Lt mm
h1 mm
l mm
AxB mm
Tinst Nm
18
90
100
65
33 x 70
75 h1
Lt = Anchor length h1 = Min. hole depth do = Hole diameter Tinst = Torque I = Axial spacing
Clean the hole before the installation
installation sequence
TOP VT Critical axial spacing Critical edge distance Minimum thickness member
Scr,N Ccr,N hmin
TOP VT 280 150 250
mm mm mm
Pull-out values in daN for applications on concrete C20/25
1 daN≃1 kg
Pull-out Shear/flexural strength
2.100 3.500
ATTENTION: An appropriate safety factor ≥ 3 should be applied on these values • As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties • It is suggested to always make pull out tests before using the anchors 242
scaffolding anchors
Vorpa TOP VT L Steel anchor for ropes and chains
concrete
natural stone
solid brick
products group To fix • ropes • chains
Suitable for • concrete • natural stone • solid brick Ideal for applications on solid brick coated by heat insulating panels and rigid insulation materials
Tensioning ropes and chains
TOP VT L with steel anchor and PVC washer
Characteristics • extralong torque controlled expansion anchor made of galvanized steel composed of anti-rotation cold formed body, expansion conical nut, oval eyebolt and PVC red washer for tensioning ropes and chains on solid brick coated by heat insulating panels and rigid insulation materials • the eyebolt can be used several times thanks to the anchor spare part • anti-rotation during the installation procedure • three-part expansion sleeve allows even load distribution and small edge and axial spacing
Installation • to be mounted aligned the wall Suggestion for use • make sure the scaffold and eyebolt are well positioned each other • apply a proper safety factor according to the each situation • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Clean the hole before the installation
installation sequence
Drill the insulation panels with a cup with a centering tip
Insert the anchor in the hole. Screw the eyebolt applying the correct torque
Fill the hole in the insulation panel with expansion foam
Drill the masonry with a Ø18 drill bit
Set the washer aligned to the wall. Installation completed
Examples of applications
243
Clean the hole by using proper cleaning brushes and pump
scaffolding anchors
product information
scaffolding anchors
Vorpa TOP VT L Steel anchor for ropes and chains
concrete
natural stone
solid brick
product code and technical data
TOP VT L with steel anchor and PVC washer
Description
3302
TOP VT L 18/130 M12
do panel Ø mm
46
do wall Ø mm
Lt mm
h1 mm
Tinst mm
AxB mm
l mm
18
130
140
75
33 x 70
180
scaffolding anchors
Code
Ideal for applications on solid brick coated by heat insulating panels and rigid insulation materials
Lt = Anchor length h1 = Min. hole depth do = Hole diameter Tinst = Torque I = Axial spacing P = Total length of the hole
Examples of applications
TOP VT L Pull-out values in daN for applications on concrete C20/25 4.500 Bending moment in daN for applications on concrete C20/25
1 daN≃1 kg
1 daN≃1 kg
300 kg bending = permanent arrow 0,4 mm 550 kg bending = permanent arrow 18 mm
ATTENTION: An appropriate safety factor ≥ 3 should be applied on these values • As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties • It is suggested to always make pull out tests before using the anchors 244
scaffolding anchors
Vorpa AV OS Steel anchor for ropes and chains
concrete
natural stone
solid brick
products group To fix • ropes • chains
Suitable for • concrete • natural stone • solid brick
Tensioning ropes and chains
AV OS eyebolt Ø25
Characteristics • torque controlled expansion anchor AV OS composed of anti-rotation cold formed body, expansion conical nut, eyebolt Ø25mm and steel washer Ø60mm for tensioning ropes and chains • the eyebolt can be used several times thanks to the anchor spare part • the anchor grants safe and easy applications
Installation • to be mounted aligned the wall Suggestion for use • apply a proper safety factor according to the each situation • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Italian Standard Telecom 18634.6
Code
507
Description
do mm
Lt mm
h1 mm
Tinst Nm
l mm
Øi mm
AV OS 20/145 M12
20
145
160
85
50
25
Lt = Anchor length h1 = Min. hole depth do = Hole diameter Tinst = Torque I = Axial spacing Øi = Internal diameter of the eyebolt
Clean the hole before the installation
installation sequence
TOP VT Pull-out values in daN for applications on concrete C20/25
1 daN≃1 kg 2.800
ATTENTION: An appropriate safety factor ≥ 3 should be applied on these values • As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties • It is suggested to always make pull out tests before using the anchors 245
scaffolding anchors
product code and technical data
scaffolding anchors
Vorpa AV OS L Steel anchor for ropes and chains
concrete
natural stone
solid brick
products group To fix • ropes • chains
Suitable for • concrete • natural stone • solid brick
scaffolding anchors
Ideal for applications on solid brick coated by heat insulating panels and rigid insulation materials
AV OS L eyebolt Ø25
Tensioning ropes and chains
product information Characteristics • extralong torque controlled expansion anchor made of galvanized steel composed of anti-rotation cold formed body, expansion conical nut, eyebolt Ø25mm and steel washer Ø60mm for tensioning ropes and chains on solid brick coated by heat insulating panels and rigid insulation materialst • the eyebolt can be used several times thanks to the anchor spare part • anti-rotation during the installation procedure • three-part expansion sleeve allows even load distribution and small edge and axial spacing
Installation • to be mounted aligned the wall Suggestion for use • make sure the scaffold and eyebolt are well positioned each other • apply a proper safety factor according to the each situation • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation Clean the hole before the installation
installation sequence 1) installation procedure
Drill the insulation panels with a cup with a centering tip
Insert the anchor in the hole. Screw the eyebolt applying the correct torque
Drill the masonry with a drill bit
Installation completed
2) to re-use the eyebolt
Examples of applications
246
Clean the hole by using proper cleaning brushes and pump
Unscrew the eyebolt and pull it out
scaffolding anchors
Vorpa AV OS L Steel anchor for ropes and chains
concrete
natural stone
solid brick
product code and technical data
AV OS L eyebolt Ø25
Description
3507 3509
AV OS L 20/145 M12 AV OS L 24/165 M16
do panel Ø mm
do wall Ø mm
Lt mm
h1 mm
Tinst Nm
Øi mm
l mm
60 60
20 24
150 165
160 180
85 150
25 25
155 170
Lt = Anchor length h1 = Min. hole depth do = Hole diameter Tinst = Torque I = Axial spacing Øi = Internal diameter of the eyebolt
h1
Examples of applications
AV OS L 20/145 - 24/165 Recommanded loads in daN for applications on concrete C20/25
1 daN≃1 kg
AV OS L 20/145 AV OS L 24/165 * bending moment
800*
Bending moment in daN for applications on concrete C20/25
1 daN≃1 kg
350 kg bending = permanent arrow 0,4 mm 600 kg bending = permanent arrow 18 mm
• As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties • It is suggested to always make pull out tests before using the anchors 247
scaffolding anchors
Code
Ideal for applications on solid brick coated by heat insulating panels and rigid insulation materials
scaffolding anchors
Vorpa VNG Steel anchor for ropes and chains
concrete
natural stone
solid brick
perforated brick
products group To fix • ropes • chains
Suitable for • concrete • natural stone • solid brick • perforated brick
scaffolding anchors
VNG with nylon plug
Tensioning ropes and chains
product information Installation • to be mounted aligned the wall
Characteristics • steel anchor composed of anti-rotation nylon plug VN and galvanized steel hook • the hook can be used several times thanks to the nylon spare part • anti-rotation during the installation procedure
Suggestion for use • apply a proper safety factor according to the each situation • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Italian Standard TELECOM 15781.8
Clean the hole before the installation
installation sequence
Code
Description
do mm
Lt mm
h1 mm
Øg mm
Lg mm
l mm
Øi mm
317
VNG 14/65
14
75
85
10
165
65
16
h1
Lt h1 do Øg Øi Lg I
= Anchor length = Min. hole depth = Hole diameter = Stem of the hook = Passage of the rope = Total length of the hook = Axial spacing
VN G Pull-out values in daN for applications on concrete C20/25
1 daN≃1 kg
Pull-out and shear
300*
* bending moment
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values • As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties • It is suggested to always make pull out tests before using the anchors 248
4
Universal and frame fixings
universal and frame fixings
Vorpa VK Universal nylon plug
concrete
natural stone
solid brick
hollow brick
perforated brick
aerated concrete
plasterboard perforated cement
products group • Suitable for • concrete • natural stone • solid brick • hollow brick • perforated brick VK V with chipboard screw • aerated concrete • plasterboard • perforated cement
To fix • light carpentry • curtains slide guides • bath accessories • lamps, paintings • post boxes • satellite dishes • wall cupboards
VK no accessories
universal and frame fixings
VK C with pan head screw
VK T with hexagonal head screw and washer
product information Characteristics • 4 way expansion form nylon plug • easy and quick fixings thanks to the four segments of the body • anti-rotation lugs stop the plug rotating in the drill hole • the fixing’s collar prevents it slipping into the drilled hole • nylon safety and reliability • temperature resistant from -40°C to +80°C • to be used with wood and clipboard screws
Installation • to be mounted aligned the wall Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation
installation sequence
On solid brick
On hollow brick
Clean the hole before the installation 252
universal and frame fixings
Vorpa VK Universal nylon plug
concrete
natural stone
solid brick
hollow brick
perforated brick
aerated concrete
plasterboard perforated cement
product code and technical data VK no accessories Code
Description
do x Lt mm
h1 mm
Øv mm
4720 4721 4722 4723 4724 4725 4726
VK 5 VK 6 VK 8 VK 10/50 VK 10/60 VK 12 VK 14
5 x 25 6 x 30 8 x 40 10 x 50 10 x 60 12 x 60 14 x 70
35 45 55 65 75 80 90
3÷4 4÷5 4,5÷6 6÷8 6÷8 8÷10 10÷12
Screw length calculation: Lv > Lt + Tfix
Code
Description
do x Lt mm
h1 mm
Tfix mm
Øv x Lv mm
4735 4736 4737 4738
VK V VK V VK V VK V
5 x 25 6 x 30 8 x 40 10 x 50
35 45 55 65
5 10 10 10
3,5 x 30 4,5 x 40 5 x 50 6 x 60
5 6 8 10
VK C with pan head screw
Code
4720C 4721C 4722C
Description
do x Lt mm
h1 mm
Tfix mm
Øv x Lv mm
VK C 5 VK C 6 VK C 8
5 x 25 6 x 30 8 x 40
35 45 55
5 10 10
3,5 x 30 4,2 x 40 4,8 x 50
VK T with hexagonal head screw and washer
Code
4722T 4723T 4725T 4726T 4727T
Description
do x Lt mm
h1 mm
Ch mm
Tfix mm
Øv x Lv mm
VK T VK T VK T VK T VK T
8 x 40 10 x 50 12 x 60 14 x 70 14 x 70
55 65 80 90 90
10 12 13 17 17
5 10 10 5 20
6 x 45 7 x 60 8 x 70 10 x 80 10 x 110
8 10 12 14 14 10/110
253
universal and frame fixings
VK V with chipboard screw
Lt = Plug length h1 = Min. hole depth do = Hole diameter tfix = Fixture thickness Øv = Screw diameter Lv = Screw length Ch = Spanner
universal and frame fixings
Vorpa VK Universal nylon plug
concrete
natural stone
solid brick
hollow brick
perforated brick
aerated concrete
plasterboard perforated cement
technical data VK V - VK C Ø5 Substrate materials Permissible loads in daN with wood screws of specified diameter
Ø6
Ø8
Ø10
Ø12
Ø14
4 30 16 10 10
5 65 22 12 10
6 75 42 21 15
8 125 80 25 25
-
-
Ø6
Ø8
Ø10
Ø12
Ø14
-
6 90 50 25 15
7 125 80 40 30
8 150 100 50 35
10 195 150 75 45
Ø screws (mm) Concrete C20/25 Solid brick** Perforated brick** Aerated concrete
1 daN≃1 kg
** Indicative loading values due to the various materials properties.
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values
VK T
universal and frame fixings
Substrate materials Ø5 Permissible loads in daN with wood screws of specified diameter Ø screws (mm) Concrete C20/25 Solid brick** Perforated brick** Aerated concrete
-
1 daN≃1 kg
**Indicative loading values due to the various materials properties.
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values
VK Substrate materials Permissible loads in daN with wood screws in assortment Ø screws (mm) Concrete C20/25 Solid brick** Perforated brick** Aerated concrete
Ø5
Ø6
Ø8
Ø10
Ø12
Ø14
4 20 10,5 6,5 6,5
5 43 14,5 8 6,5
6 50 28 14 11
8 83 53 16 16
10 95 60 30 20
12 120 90 45 25
** Indicative loading values due to the various materials properties.
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values
Examples of applications
254
1 daN≃1 kg
universal and frame fixings
Vorpa TVZ Universal nylon plug
concrete
natural stone
solid brick
hollow brick
perforated brick
aerated concrete
perforated cement
products group To fix • window and door frames • llght structural works • wooden substrucrures • handrail • light carpentry • curtains slide guides • bath accessories • lamps, paintings • post boxes • satellite dishes • wall cupboards
• Suitable for • concrete • natural stone • solid brick • hollow brick TVZ V • perforated brick TVZ V INOX A2 with chipboard screw • aerated concrete • perforated cement TVZ no accessories
*
A2 INOX 304
*
product information • multiple radial expansion behaviour on perforated masonry • knotting behaviour on hollow masonry • temperature resistant from -40°C to + 80°C Installation • to be mounted aligned the wall Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation
installation sequence
On solid brick
On hollow brick
Clean the hole before the installation
Examples of applications
255
universal and frame fixings
Characteristics • multi-purpose anchor, suitable for all base materials. Concrete and solid masonry materials, by fully radial expansion perforated masonry, by multiple radial expansion hollow masonry, by knotting • special wings to avoid turning • the special anti-rotation wings on the nylon sleeve provides easy and safe installation on all types of material, avoiding any rotation of the nylon sleeve while the screw is installed • no waiting time before loading • ideal for fixing of facade, frames and general fastenings • fully radial expansion behaviour on concrete and solid masonry
universal and frame fixings
Vorpa TVZ Universal nylon plug
concrete
natural stone
solid brick
hollow brick
perforated brick
aerated concrete
perforated cement
product code and technical data
universal and frame fixings
TVZ no accessories
Code
Description
hmin mm
do x Lt mm
for screws mm
h1 mm
Tfix mm
hef mm
df mm
4739 4740 4741 4742 4760 4761 4762 4763 4764
TVZ 6x32 TVZ 6x45 TVZ 8x42 TVZ 8x52 TVZ 10x50 TVZ 10x60 TVZ 12x60 TVZ 14x70 TVZ 14x100
60 80 75 100 100 110 110 120 160
6x32 6x45 8x42 8x52 10x50 10x60 12x60 14x70 14x100
4,5 4,5 5,0 5,0 6,0 6,0 8,0 10,0 10,0
50 60 60 70 70 80 80 90 130
10 5 5 5 5 5 5 5 5
32 45 42 52 50 60 60 70 100
5,5 5,5 6 6 7 7 9 12 12
*
TVZ V with chipboard screw
TVZ INOX A2 with A2 SS chipboard screw
Code
Description
hmin mm
do x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
hef mm
df mm
4743 4744 4745 4746 4770
TVZ V TVZ V TVZ V TVZ V TVZ V
6x32 6x45 8x42 8x52 10x50
60 80 75 100 100
6x32 6x45 8x42 8x52 10x50
4,5x40 4,5x50 5,0x50 5,0x60 6,0x60
50 60 60 70 70
10 5 5 5 5
32 45 42 52 50
5,5 5,5 6 6 7
4747 4748 4749 4750 4780
TVZ V A2 6x32 TVZ V A2 6x45 TVZ V A2 8x42 TVZ V A2 8x52 TVZ V A2 10x50
60 80 75 100 100
6x32 6x45 8x42 8x52 10x50
4,5x40 4,5x50 5,0x50 5,0x60 6,0x60
50 60 60 70 70
10 5 5 5 5
32 45 42 52 50
5,5 5,5 6 6 7
On solid brick
A2 INOX 304
*
Lt = Plug length h1 = Min. hole depth do = Hole diameter tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Diameter of clearance hole in the fixture Screw length calculation: Lv > Lt + Tfix
On hollow brick
TVZ Substrate materials Maximum raccommended loads kg Ø screws (mm) Concrete C20/25 Autoclaved aerated concrete 3 N/mm2 Vulcanic tuff 7,5 N/mm2 Hollow brick 1,5 N/mm2 Solid brick 1,7 N/mm2 Hollow concrete thickness member equal to 2,5 cm Plasterboard panels 12mm
TVZ 6
TVZ 8
TVZ 10
TVZ 12
TVZ 14
Ø 4,5 40 6 6 30 20 30 15
Ø5 50 6 8 40 25 30 15
Ø6 60 20 10 35 30 30 15
Ø8 85 35 12 60 45 35 -
Ø 10 120 40 40 70 80 -
256
universal and frame fixings
Vorpa VN Universal nylon plug
concrete
natural stone
solid brick
products group
VN no accessories
VN A with chipboard screw
VN C with chipboard screw
VN 4 with zincplated hook
VN T with hexagonal head screw and washer
product information Characteristics • anti-rotation nylon plug 2 way expansion • fast and simple installation • temperature resistant from -40°C to +80°C • the anti-rotation lock prevents the plug rotation in the drill hole • high level of installation safety • possibility to direct the expansion forces to let them run parallel to the edge of the building material • to be used with wood and chipboard screws
Installation • to be mounted aligned the wall Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation
installation sequence
Clean the hole before the installation Examples of applications
257
universal and frame fixings
VN B flanged body no accessories
To fix • light carpentry • curtains slide guides • bath accessories • lamps, paintings • post boxes • satellite dishes • wall cupboards • motion sensors • information boards
Suitable for • concrete • natural stone • solid brick
universal and frame fixings
Vorpa VN Universal nylon plug
concrete
natural stone
solid brick
product code and technical data
universal and frame fixings
VN B flanged body no accessories
VN no accessories
Code
Description
do x Lt mm
h1 mm
Øv mm
435 436 437 438 438S 439
VN B flanged body 5 VN B flanged body 6 VN B flanged body 8 VN B flanged body 10/50 VN B flanged body 10/60 VN B flanged body 12
5 x 26 6 x 31 8 x 41 10 x 51 10 x 61 12 x 61
35 40 55 70 80 75
3÷4 4÷5 4,5÷6 6÷8 6÷8 8÷10
649 630 631 648 632 633 3633 634 635 654
VN nylon plug VN nylon plug VN nylon plug VN nylon plug VN nylon plug VN nylon plug VN nylon plug VN nylon plug VN nylon plug VN nylon plug
4 x 20 5 x 25 6 x 30 7 x 30 8 x 40 10 x 50 10 x 60 12 x 60 14 x 75 16 x 80
25 35 40 40 55 70 80 75 85 90
2÷3 3÷4 4÷5 4÷5 4,5÷6 6÷8 6÷8 8÷10 10÷12 12÷14
4 5 6 7 8 10/50 10/60 12 14 16
VN A with chipboard screw Code
Description
VN C with chipboard screw
do x Lt mm
Tfix mm
h1 mm
Øv x Lv mm
477 478 479 480
VN A flanged body VN A flanged body VN A flanged body VN A flanged body
5 6 8 10
5 x 26 6 x 31 8 x 41 10 x 51
1,5 6 5 4
35 40 55 70
3,5 x 30 4,5 x 40 5 x 50 6 x 60
644 645 646 647
VN C nylon plug VN C nylon plug VN C nylon plug VN C nylon plug
5 6 8 10
5 x 25 6 x 30 8 x 40 10 x 50
1,5 6 5 4
35 40 55 70
3,5 x 30 4,5 x 40 5 x 50 6 x 60
Examples of applications
258
Lt = Plug length h1 = Min. hole depth do = Hole diameter tfix = Fixture thickness Øv = Screw diameter Lv = Screw length Screw length calculation: Lv > Lt + Tfix
universal and frame fixings
Vorpa VN Universal nylon plug
concrete
natural stone
solid brick
identificazione prodoto e technical data
VN T with hexagonal head screw and washer
Code
850 851 852 853 856 854
Description
VN T nylon plug 8 VN T nylon plug 10 VN T nylon plug 12 VN T nylon plug 14/75 VN T nylon plug 14/100 VN T nylon plug 16
do x Lt mm
h1 mm
Tfix mm
Øv x Lv mm
8 x 40 10 x 50 12 x 60 14 x 75 14 x 100 16 x 80
55 70 75 90 115 90
5 10 10 10 10 5
6 x 45 7 x 60 8 x 70 10 x 80 10 x 110 12 x 90
VN 4 with zincplated hook
Code
449
Description
do x Lt mm
h1 mm
VN 4
4 x 20
25
Examples of applications
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values VN Substrate materials Tensile resistance in daN with wood screws Ø screws (mm) Concrete C20/25 Solid brick** Double brick UNI with plaster**
VN 4
VN 5
VN 6
VN 8
VN 10
VN 12
VN 14
3 50
4 200 170 200
5 300 250 300
6 410 400 -
8 700 -
10 1020 -
VN 16 1 daN≃1 kg
12 1600 -
14 1900 -
115
**Indicative loading values due to the various materials properties.
259
universal and frame fixings
Lt = Plug length h1 = Min. hole depth do = Hole diameter tfix = Fixture thickness Øv = Screw diameter Lv = Screw length Ch = Spanner Øg = Hook diameter Lg = Hook length
universal and frame fixings
Vorpa SU P Universal nylon plug
concrete
natural stone
solid brick
perforated brick
aerated concrete
plasterboard perforated cement
boards and panels
products group Suitable for • concrete • natural stone • solid brick • perforated brick • aerated concrete SU PV • plasterboard with chipboard screw • perforated cement • boards and panels
To fix • light carpentry • curtains slide guides • bath accessories • lamps, paintings • post boxes • satellite dishes • wall cupboards
SU P no accessories
universal and frame fixings
SU PC with pan head screw cross recess
SU PO with wire hook
product information Characteristics • universal multipurpose nylon plug • easy and quick fixings thanks to the segments of the body • anti-rotation lugs stop the plug rotating in the drill hole • the fixing’s collar prevents it slipping into the drilled hole • nylon safety and reliability • temperature resistant from -40°C to +80°C • high level of installation security
Installation • to be mounted aligned the wall Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation
installation sequence
Clean the hole before the installation Examples of applications
On solid brick
On hollow brick
On plasterboard and panels
260
universal and frame fixings
Vorpa SU P Universal nylon plug
concrete
natural stone
solid brick
perforated brick
aerated concrete
plasterboard perforated cement
boards and panels
product code and technical data SU P no accessories Code
Description
do x Lt mm
h1 mm
Øv mm
6900 6901 6902 6903
SU P 6/35 SU P 6/45 SU P 8 SU P 10
6 x 35 6 x 45 8 x 50 10 x 60
45 55 60 80
3÷3,5 3÷3,5 4÷5 5÷6
SU PV with chipboard screw
Description
do x Lt mm
h1 mm
Tfix mm
Sc mm
Øv x Lv mm
6912 6913 6914 6915
SU PV 6/35 SU PV 6/45 SU PV 8 SU PV 10
6 x 35 6 x 45 8 x 50 10 x 60
45 55 60 80
10 10 10 20
6 6 6 6
3,5x45 3,5x55 4,5x60 6x80
SU PC with pan head screw cross recess
Code
Description
do x Lt mm
h1 mm
Tfix mm
Sc mm
Øv x Lv mm
6916 6917 6918
SU PC 6/35 SU PC 6/45 SU PC 8/50
6 x 35 6 x 45 8 x 50
45 55 60
10 10 10
6 6 6
3,5x45 3,5x55 4,5x60
Lt = Plug length h1 = Min. hole depth do = Hole diameter tfix = Fixture thickness Øv = Screw diameter Lv = Screw length Sc = Substrate thickness Øo = Wire hook diameter Lo = Wire hook length Screw length calculation: Lv > Lt + Tfix
SU PO with wire hook
Code
Description
do x Lt mm
h1 mm
Øo x Lo mm
Sc mm
Øv x Lv mm
6920 6921
SU PO 6/45 SU PO 8/50
6 x 45 8 x 50
45 60
3,9x45 4,4x55
6 6
3,5x45 3,5x55
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values SU P Substrate materials Tensile resistance in daN with wood screws Ø screws (mm) Concrete C20/25 Solid brick** Double brick UNI with plaster** Plasterboard mm 10
SU P Ø6
SU P Ø8
SU P Ø10
3,5x45/55 100 70 40 35
4,5x60 180 140 60 42
6x80 280 160 80 42
1 daN≃1 kg
**Indicative loading values due to the various materials properties.
261
universal and frame fixings
Code
universal and frame fixings
Vorpa VR Universal nylon plug
concrete
natural stone
solid brick
perforated brick
aerated poroton
aerated concrete
plasterboard perforated cement
products group Suitable for • concrete • natural stone • solid brick • perforated brick VR V • aerated poroton with chipboard screw • aerated concrete • plasterboard • perforated cement
To fix • pictures • lighting • skirting • shelves • mirror cabinets • letter boxes • curtain rails • electrical installation
VR no accessories
universal and frame fixings
product information Characteristics • HD polyethylene plug suitable for applications on compact and hollow materials • safe and quick fixings • special anti-rotation wings that prevents the plug turning in the hole on installation • the plug’s neck avoid the introduction of the plug inside the hole • resistant to temperatures from -40°C to +70°C • to be used with wood screws
Installation • to be mounted aligned the wall Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation
installation sequence
Clean the hole before the installation
Examples of applications
On solid brick
On hollow brick
On plasterboard and panels
262
universal and frame fixings
Vorpa VR Universal nylon plug
concrete
natural stone
solid brick
perforated brick
aerated poroton
aerated concrete
plasterboard perforated cement
product code and technical data VR no accessories Code
531 532 533
Description
do x Lt mm
h1 mm
Øv mm
VR 6 VR 8 VR 10
6 x 38 8 x 51 10 x 61
48 61 71
3÷5 3,5÷7 5÷8
VR V with chipboard screw
Code
do x Lt mm
h1 mm
Tfix mm
Sc mm
Øv x Lv mm
VR V 6 VR V 8 VR V 10
6 x 38 8 x 51 10 x 61
48 61 71
8 8 8
6 6 6
4x45 5x60 6x70
Lt = Plug length h1 = Min. hole depth do = Hole diameter tfix = Fixture thickness Øv = Screw diameter Lv = Screw length Sc = Substrate thickness Screw length calculation: Lv > Lt + Tfix
Examples of applications
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values VR Substrate materials Tensile resistance in daN with wood screws
VR Ø6
VR Ø8
VR Ø10
Ø screws (mm) Concrete C20/25 Solid brick** Double brick UNI with plaster** Plasterboard mm 10
4x45 100 70 40 30
5x60 160 130 55 40
6x70 190 140 75 40
**Indicative loading values due to the various materials properties.
263
1 daN≃1 kg
universal and frame fixings
541 542 543
Description
universal and frame fixings
Vorpa ZV Universal nylon plug
concrete
natural stone
solid brick
perforated brick
aerated poroton
aerated concrete
perforated cement
products group
ZV
ZVP extralong
Suitable for • concrete • natural stone • solid brick • perforated brick • aerated poroton • aerated concrete • perforated cement
To fix • curtain slide guides • lighting, paintings • post poxes • satellite dishes • shelves, profiles • door stops • ceilings, hangers • motion sensors • bath accessories • wall mounting for tv and radio
Leaf through the Technical Data Sheet to verify the wide range of pre-assembled accessories ZV
universal and frame fixings
product information Characteristics • nylon wallplug available in two different sizes 9-12 mm Ø • the wallplug expands upon return of the cone, when the accessory is tightened • the wallplug’s particular shape guarantees effective expansion • the side lugs prevent the wallplug from twisting around on its own axis • the opening along its length guarantees perfect adherence even on non solid materials • the collar prevents stressing claddings • useful in a wide range of applications • can be used on most popular building materials
Installation • to be mounted aligned the wall Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation
installation sequence ZV with screw
Clean the hole before the installation
On solid brick
product code and technical data
ZV screw Code
ZVP extra long screw Description
do mm
Lt mm
h1 mm
Tfix mm
975 976
ZV 9 screw ZV 12 screw
9 12
45 50
61 71
10 10
636 638
ZVP 9 extra long screw ZVP 12 extra long screw
9 12
60 60
70 70
10 10
264
Lt h1 do tfix
= Anchor length = Min. hole depth = Hole diameter = Fixture thickness
universal and frame fixings
Vorpa ZV Universal nylon plug
concrete
natural stone
solid brick
perforated brick
aerated poroton
aerated concrete
perforated cement
installation sequence ZV with accessories On solid brick
On hollow brick
Clean the hole before the installation
product code and technical data
ZV medium hook
ZVP extra long short hook
ZVP extra long medium hook
universal and frame fixings
ZV short hook
ZV long hook
Description
do mm
Lt mm
h1 mm
G mm
977 978
ZV 9 short hook ZV 12 short hook
9 12
45 50
55 60
7 7
979 980
ZV 9 medium hook ZV 12 medium hook
9 12
45 50
55 60
11 11
981 982
ZV 9 long hook ZV 12 long hook
9 12
45 50
55 60
18 22
637 639 667
ZVP 9 extra long short hook ZVP 12 extra long short hook ZVP 12 extra long medium hook
9 12 12
60 60 60
70 70 70
7 7 11
Code
Examples of applications
265
Lt = Anchor length h1 = Min. hole depth do = Hole diameter tfix = Fixture thickness P = Wire hook G = Hook Ø0 = Eyebolt diameter ØbxLb= Stud diameter x stud length
universal and frame fixings
Vorpa ZV Universal nylon plug
concrete
natural stone
solid brick
perforated brick
aerated poroton
aerated concrete
perforated cement
product code and technical data
ZV eyebolt
ZV wire hook
ZVP extra long eyebolt
ZVP extra long wire hook
universal and frame fixings
Code
Description
do mm
Lt mm
h1 mm
Øo mm
983 984
ZV 9 eyebolt ZV 12 eyebolt
9 12
45 50
55 60
12 13
985 986
ZV 9 wire hook ZV 12 wire hook
9 12
45 50
55 60
12 13
667 973 974
ZVP 12 ZVP 12 ZVP 12
12 12 12
60 60 60
70 70 70
13
extra long medium hook extra long eyebolt extra long wire hook
P mm
G mm
P
11 13
installation sequence ZV with accessories
Clean the hole before the installation
On solid brick
product code and technical data
ZV stud mm 30
ZV stud mm 50
ZV stud M6
Description
do mm
Lt mm
h1 mm
ØbxLb mm
Tfix mm
987 988
ZV 9 stud M4x30 ZV 12 stud M5x30
9 12
45 50
55 60
M4x30 M5x30
10 10
991 993
ZV 9 stud M4x50 ZV 12 stud M5x50
9 12
45 50
55 60
M4x50 M5x50
25 25
992
ZV 12 stud M6x20
12
50
60
M6x20
10
Code
266
Lt = Anchor length h1 = Min. hole depth do = Hole diameter tfix = Fixture thickness P = Wire hook G = Hook Ø0 = Eyebolt diameter ØbxLb= Stud diameter x stud length
universal and frame fixings
Vorpa ZV Universal nylon plug
concrete
natural stone
solid brick
perforated brick
aerated poroton
aerated concrete
perforated cement
installation sequence ZV doorstop
Clean the hole before the installation
On solid brick
product code and technical data
ZV flat hook
957 969
Description
do mm
Lt mm
h1 mm
G mm
ZV 9 flat hook ZV 12 adjustable hook
9 12
45 50
55 60
14 5
do mm
Lt mm
h1 mm
AxB mm
9 9
45 45
55 55
Ø20x25 Ø20x25
Lt h1 do tfix G
universal and frame fixings
Code
ZV adjustable hook
= Anchor length = Min. hole depth = Hole diameter = Fixture thickness = Hook
ZV doorstop PVC Code
989 990
Description
ZV 9 white doorstop ZV 9 black doorstop
technical data ZV ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values ZV 9 Code Pull out values in daN Aerated poroton Concrete C20/25 *bending moment
975
*977
*979
*981
*983
*985
991
987
636
*637
160 220
50 50
50 50
50 50
50 50
50 50
160 220
160 220
160 220
50 50
976
*978
*980
*982
*984
*986
993
988
992
638
*639
*667
210 350
90 90
90 90
90 90
90 90
90 90
210 350
210 350
210 350
210 350
90 90
90 90
1 daN≃1 kg
ZV 12 Code Pull out values in daN Aerated poroton Concrete C20/25 *bending moment
*973
*974 1 daN≃1 kg 90 90 90 90
As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties 267
universal and frame fixings
Vorpa SV Universal ligth fixing
concrete
natural stone
solid brick
products group Suitable for • concrete • natural stone • solid brick
SV
To fix • curtain slide guides • lighting, paintings • post poxes • satellite dishes • shelves, profiles • door stops • ceilings, hangers • motion sensors • bath accessories • wall mounting for tv and radio
SVP extra long
Leaf through the Technical Data Sheet to verify the wide range of pre-assembled accessories SV
universal and frame fixings
product information Characteristics • steel wallplug available in three different sizes 6-8-9 mm Ø • the wallplug expands upon return of the cone, when the accessory is tightened • thanks to a vast assortment of special accessories this wallplug is useful in a wide range of applications • expansion is excellent thanks to the zincplated steel shieldings • the side lugs prevent the wallplug from twisting around on its own axis • the wallplug can be used on most popular building materials
Installation • to be mounted aligned the wall Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation
installation sequence SV with screw
Clean the hole before the installation
On solid brick
product code and technical data
SV screw
SV extra long with hexagonal screw
Code
Description
1675 1674 675 676
SV 6 screw SV 6 long screw SV 8 screw SV 9 screw
2860 2861
SVP extra long with screw
do mm
Lt mm
h1 mm
Tfix mm
6 6 8 9
25 25 40 45
35 35 50 55
5 15 10 10
SVP 9 extra long with hexagonal screw 9 9 SVP 9 extra long with screw
60 60
70 70
10 10
268
Lt h 1 d o tfix
= Anchor length = Min. hole depth = Hole diameter = Fixture thickness
universal and frame fixings
Vorpa SV Universal ligth fixing
concrete
natural stone
solid brick
installation sequence SV with accessories
Clean the hole before the installation
On solid brick
product code and technical data
SV short hook
SV medium hook
SVP extra long short hook
SVP extra long medium hook
SV long hook
Lt mm
h1 mm
G mm
SV 6 short hook SV 8 short hook SV 9 short hook
6 8 9
25 40 45
35 50 55
8 11 13
679 680
SV 8 medium hook SV 9 medium hook
8 9
40 45
50 55
15 17
681 682
SV 8 long hook SV 9 long hook
8 9
40 45
50 55
22 30
SVP 9 extra long short hook SVP 9 extra long medium hook
9 9
60 60
70 70
15 20
do mm
Lt mm
h1 mm
Øo mm
P mm
8 13 14
6 8 9
Description
1677 677 678
2862 2863
SV eyebolt
SV wire hook
SV extra long eyebolt
SV extra long wire hook
Code
Description
1683 683 684
SV 6 eyebolt SV 8 eyebol SV 9 eyebol
6 8 9
25 40 45
35 50 55
1685 685 686
SV 6 wire hook SV 8 wire hook SV 9 wire hook
6 8 9
25 40 45
35 50 55
2864 2865
SVP 9 extra long eyebolt SVP 9 extra long wire hook
9 9
60 60
70 70
269
14 9
universal and frame fixings
do mm
Code
Lt = Anchor length h1 = Min. hole depth do = Hole diameter tfix = Fixture thickness P = Wire hook G = Hook Ø0 = Eyebolt diameter ØbxLb= Stud diameter x stud length
universal and frame fixings
Vorpa SV Universal ligth fixing
concrete
natural stone
solid brick
installation sequence SV with accessories
On solid brick
Clean the hole before the installation
universal and frame fixings
On solid brick
product code and technical data
SV stud M6x20 Code
687 689 688
Description
SV 8 stud M4x40 SV 9 stud M6x20 SV 9 stud M5x40
SV flat hook Code
745 747
SV stud M4 - M5 do mm
Lt mm
h1 mm
ØbxLb mm
8 9 9
40 45 45
50 55 55
M4x40 M6x20 M5x40
SV adjustable hook Description
SV 8 flat hook SV 9 adjustable hook
do mm
Lt mm
h1 mm
G mm
8 9
40 45
50 55
14 5
Examples of applications
270
Lt h1 do tfix G
= Anchor length = Min. hole depth = Hole diameter = Fixture thickness = Hook
universal and frame fixings
Vorpa SV Universal ligth fixing
concrete
natural stone
solid brick
installation sequence SV doorstop
Clean the hole before the installation
On solid brick
product code and technical data
SV doorstop PVC Code
SV 9 white doorstop SV 9 black doorstop
do mm
Lt mm
h1 mm
AxB mm
9 9
45 45
55 55
Ø20x25 Ø20x25
universal and frame fixings
756 754
Description
Lt = Anchor length h1 = Min. hole depth do = Hole diameter
Examples of applications
technical data SV ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values SV 6 1675 - *1677 - *1683 - *1685
Code Pull out values in daN Concrete C20/25 *bending moment
1 daN≃1 kg
40
SV 8 Code Pull out values in daN Concrete C20/25 *bending moment
675
*677 - *679 - *681 - *683 - *685
687
300
40
300
676 - 2860 - 2861
*678 - *680 - *682 - *684 - *686 - *2862 - *2863 - *2864 - *2865
370
90
1 daN≃1 kg
SV 9 Code Pull out values in daN Concrete C20/25 *bending moment
688 - 689 1 daN≃1 kg 370
As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties 271
universal and frame fixings
Vorpa VEO Universal ligth fixing for ceilings
concrete
products group VEO
Suitable for • concrete
To fix • ceilings, hangers • lightings, ventilation systems • suspended ceilings • cable conduits
product information
universal and frame fixings
Characteristics • steel anchor with expansion clip for solid material • suitable for ceilings and suspended hangers on limited material thickness • simple hammerset installation and a short processing time • the extremely short anchor depth prevents reinfocement hits • the expansion clip guarantees a solid hold when fixed in the drill hole, and prevents it falling out during overhead installation • the nail anchor expands automatically under load. The cone is pulled into the expansion clip and expands it against the drill hole wall
Installation • to be mounted aligned the wall Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation
Clean the hole before the installation
installation sequence
product code and technical data
Code
Description
559 1559
VEO 6/50 VEO 6/60
do mm
Lt mm
h1 mm
6 6
50 60
40 50
ATTENTION: An appropriate safety factor ≥ 4 should be applied on these values VE.O Pull out values in daN Concrete C20/25 Examples of applications
272
VEO 6/50
VEO 6/60
80
80
1 daN≃1 kg
universal and frame fixings
Vorpa HC Universal ligth fixing for plasterboard
aerated concrete
plasterboard boards and panels
products group HC - L 31 mm no accessories
Suitable for • aerated concrete • plasterboard • boards and panels
HC TC - L 31 mm with cylinder head screw
To fix • skirting • lamps, paintings • curtains slide guides • bath accessories • profiles • convectors • information boards • motion sensors
HC TSP - L 31 mm with chipboard screw
universal and frame fixings
HC - L 39 mm no accessories
HC TC - L 39 mm with cylinder head screw
HC TSP - L 39 mm with chipboard screw
product information Characteristics • self-threading zamak fixing for plasterboard, panels and light weight substrate materials • need to pre-drill • suitable for wood, self-tapping and chipboard screws of 4.0 to 5.0 mm diameter • quick and easy installation work • can be used with the most wideranging screws, hooks and eye screws. This allows for a broad range of applications • the sharp, self-tapping thread enables a secure,positive fit fixing • high load-bearing capacity, no special setting tool is required • only a small amount of space is required behind the board • suitable for prepositioned installation
Installation • to be mounted aligned the wall Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • the installation torque should be limited when using a battery operated screwdriver • no suitable for tiled plasterboard
Examples of applications
273
universal and frame fixings
Vorpa HC Universal ligth fixing for plasterboard
aerated concrete
plasterboard boards and panels
installation sequence
product code and technical data HC - L 31 mm no accessories
universal and frame fixings
Code
520M 522M
HC - L 39 mm no accessories
Description
Lt mm
Tfix mm
Si mm
ØvxLv mm
HC 31 HC 39
31 39
0-15 0-20
35 44
4,5x25 4,5x30
HC TC - L 31 mm with cylinder head screw
HC TC - L 39 mm with cylinder head screw
Code
Description
Lt mm
Tfix mm
Si mm
ØvxLv mm
520V 522
HC TC 31 HC TC 39
31 39
0-15 0-20
35 44
4,5x25 4,5x30
HC TSP - L 31 mm with chipboard screw
HC TSP - L 39 mm with chipboard screw
Code
Description
Lt mm
Tfix mm
Si mm
ØvxLv mm
2537 2539
HC TSP 31 HC TSP 39
31 39
0-15 0-20
35 44
4,5x25 4,5x30
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values HC Pull out values in daN Plasterboard 9,5 mm Plasterboard 12,5 mm Plasterboard ≥ 25 mm
274
HC L.31
HC L.39
30 45 60
45 55 70
1 daN≃1 kg
universal and frame fixings
Vorpa HZ - HB Universal ligth fixing for plasterboard
aerated concrete
wood
plasterboard boards and panels
products group HZ 29 no accessories
Suitable for • aerated concrete • wood • plasterboard • boards and panels
To fix • skirting • lightings, paintings • curtains slide guides • bath accessories • shelves • convectors • motion sensors
HZV 29 TC with cylinder head screw
HZV 29 TSP with chipboard screw
HB 30 with countersunk head screw
product information Installation • to be mounted aligned the panel Suggestion for use • respect the installation data • the installation torque should be limited when using a battery operated screwdriver • no suitable for tiled plasterboard
installation sequence
product code and technical data
Code
2523s 2523 2755 521
Description
Lt mm
Tfix mm
ØvxLv mm
HZ 29 no accessories HZV 29 TC with cylinder head screw HZV 29 TSP with chipboard screw HB 30 with countersunk head screw
29 29 29 30
13 13 13 12
4,5x25 4,5x25 4,5x25 3x25 Lt = Plug length tfix = Fixture thickness Øv = Screw diameter Lv = Screw length Si = Interspace Screw length calculation: Lv > Lt + Tfix
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values HZ - HB Pull out values in daN Plasterboard 10mm Plasterboard > 12,5 mm Plasterboard ≥ 25 mm
275
HZ
HB
40 50 67
20 30 45
1 daN≃1 kg
universal and frame fixings
Characteristics • self-tapping nylon fixing for plasterboard • no need to pre-drill • quick and easy installation • suitable for wood, self-tapping and chipboard screws
universal and frame fixings
Vorpa HS Universal ligth fixing for plasterboard
aerated concrete
perforated plasterboard boards and brick panels
products group Suitable for • aerated concrete • perforated brick • plasterboard • boarda and panels
HS no accessories
To fix • curtain slide guides • lighting, paintings • post poxes • satellite dishes • shelves, profiles • door stops • ceilings, hangers • motion sensors • bath accessories • wall mounting for tv and radio
HSV with chipboard screw
universal and frame fixings
product information Characteristics • nylon plug with toggle designed for fixing on hollow materials plasterboard, boards and panels • suitable for metric and chipboard screws • the expanding arms swing open and press onto the reverse side of the board • reduced thermal transfer
Installation • to be mounted aligned the panel Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation Clean the hole before the installation
installation sequence
product code and technical data HS no accessories
HS V with chipboard screw
Code Description
Lt mm
h1 mm
1050 HS 10x38 1051 HS 10x47
38 47
30 42
1056 HSV 10x38 1057 HSV 10x47
38 47
30 42
ØvxLv mm
Øv mm
do mm
Tfix mm
4 4
10 10
12 19
10 10
12 19
4x50 4x55
Lt = Plug length h1 = Min. hole depth do = Hole diameter tfix = Fixture thickness Øv = Screw diameter Lv = Screw length
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values
Screw length calculation: Lv > Lt + Tfix
HU HS Ø10 Pull out values in daN Plasterboard Hollow brick
40 40
276
1 daN≃1 kg
universal and frame fixings
Vorpa HU Universal ligth fixing for plasterboard
perforated plasterboard boards and brick panels
products group HU with screw
Suitable for • perforated brick • plasterboard • boards and panels
To fix • skirting • lightings, paintings • curtains slide guides
HU GM with hook
HU GA with wire hook
product information Installation • to be mounted aligned the panel Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data
installation sequence
Examples of applications
277
universal and frame fixings
Characteristics • metal cavity fixing with metric screw • quick, easy and secure installation • the metric internal thread allows the attachment to be removed and refitted several times • the expanding arms ensure a large supporting surface • the claws around the edge of the fixing penetrate the board building material, preventing the fixing from rotating • load bearing capacity • during the installation procedure the expanding arms swing open and press onto the reverse side of the board • the metal fixing can be installed using installation pliers. If using a battery operated screwdriver or screwdriver for installation, the preassembled screws must be removed first
universal and frame fixings
Vorpa HU Universal ligth fixing for plasterboard
perforated plasterboard boards and brick panels
product code and technical data
universal and frame fixings
HU with screw Code
Description
Lt mm
ØvxLv mm
do mm
h1 mm
dp mm
Tfix mm
1766 1767 1768 1769 770 771 1775 772 773 774
HU 4/20/7 HU 4/32/7 HU 4/38/7 HU 4/45/7 HU 5/37/9 HU 5/52/9 HU 5/65/9 HU 6/52/10 HU 6/65/10 HU 6/80/10
20 32 38 45 37 52 65 52 65 80
M4 x 28 M4 x 40 M4 x 45 M4 x 52 M5 x 45 M5 x 60 M5 x 72 M6 x 60 M6 x 72 M6 x 92
8 8 8 8 10 10 10 12 12 12
30 42 48 55 47 62 75 62 75 90
2-4 3-8 10-15 18-22 6-10 8-12,5 20-30 7-16 18-26 32-42
14 18 20 20 22 25 25 30 30 30
Lt = Anchor length before installation h1 = Min. hole depth do = Hole diameter tfix = Fixture thickness Øv = Screw diameter Lv = Screw length G = Hook Ø = Diameter of the hook dp = Panel thickness
HU GM with hook
Code
Description
Lt mm
ØvxLv mm
do mm
h1 mm
dp mm
G mm
1116
HU GM 5/37/9
37
M5 x 45
10
47
6-10
12
HU GA with wire hook
Code
Description
Lt mm
ØvxLv mm
do mm
h1 mm
dp mm
Ø mm
1117
HU GA 5/37/9
37
M5 x 45
10
47
6-10
12
Code
Description
749 53128
code 53128
HTU assembly plier HTU eye and bolt adapter
code 749
Examples of applications
ATTENTION: An appropriate safety factor ≥ 3 should be applied on these values HU HU 4
HU 5
45 45 75 70 70
45 45 75 90 90 90
Pull out values in daN Screw - Plasterboard 9,5 mm Screw - Plasterboard 12,5 mm Screw - Plasterboard 19-20 mm Screw - Plasterboard ≥ 25 mm Hook - bending moment Eyebolt - bending moment
278
HU 6 1 daN≃1 kg 45 45 75 90 110 110
universal and frame fixings
Vorpa DOUBLE-SIDED TAPE NAF Universal ligth fixing for plasterboard
metal profiles
boards and panels
products group Suitable for • plasterboard wall partition • guides to the paving
To fix • metal profiles • plasterboard panels • boards and panels
DOUBLE-SIDED TAPE NAF
Specific for noise reduction
product information • ideal for metal profiles to be applied on non-drillable floors and ceilings • suitable for joining of plasterboard walls, for the laying of partition walls and in the fixing of guides to the paving
product code and technical data
Double-sided sealing tape for partition walls
Code
Width/Length
Weigth
Adhesive weigth
Polyethylene thickness
Thermal conductivity 40°C
* * 58770 58771 *
mm 30x20 ml mm 40x20 ml mm 50x20 ml mm 70x20 ml mm 95x20 ml
73 g/m2 73 g/m2 73 g/m2 73 g/m2 73 g/m2
25 ± 10% g/m2 25 ± 10% g/m2 25 ± 10% g/m2 25 ± 10% g/m2 25 ± 10% g/m2
3 mm 3 mm 3 mm 3 mm 3 mm
0,039 W/mK 0,039 W/mK 0,039 W/mK 0,039 W/mK 0,039 W/mK
* Available on request
Examples of applications
279
universal and frame fixings
Characteristics • double-sided tape in polythene foam for insulation panels • product waterproof, hotmelt adhesive and fronts in monosiliconati • specific for noise reduction. To be applied on metal profiles for plasterboard partition walls
universal and frame fixings
Vorpa PC Universal ligth fixing for plasterboard
metal profiles
boards and panels
products group Suitable for PCV self-drilling screw with fine thread • profiles
To fix • metal plates • thin profiles • substructures of plasterboards • connection of metal profiles
• metal plates
PCA self-tapping screw with fine thread and drill tip PCF self-tapping screw with drill tip and cylindric head
product information Characteristics • self-drilling and self-tapping screws • the screws are phosphate-threated and thus provide the necessary corrosion protection
• efficient solution for serial machine assembly • safe and economical • no pre-drilling required
universal and frame fixings
product code and technical data PCV self-drilling screw with fine thread Code
Description
ØvxLv mm
Tfix max mm
Øt mm
Ch mm
2850 2851 2852 2853
PCV 3,5x25 PCV 3,5x35 PCV 3,5x45 PCV 3,5x55
3,5x25 3,5x35 3,5x45 3,5x55
1 1 1 1
8 8 8 8
Ph2 Ph2 Ph2 Ph2
PCA self-tapping screw with fine thread and drill tip Code
Description
ØvxLv mm
Tfix max mm
Øt mm
Ch mm
2890 2891 2892
PCA 3,5x25 PCA 3,5x35 PCA 3,5x45
3,5x25 3,5x35 3,5x45
2,25 2,25 2,25
8 8 8
Ph2 Ph2 Ph2
PCF self-tapping screw with drill tip and cylindric head Code
Description
ØvxLv mm
Tfix max mm
Øt mm
Ch mm
2895 2897 2898 2896
PCF 4,2x13 PCF 4,2x16 PCF 4,2x19 PCF 4,2x25
4,2x13 4,2x16 4,2x19 4,2x25
3 3 3 3
10,5 10,5 10,5 10,5
Ph2 Ph2 Ph2 Ph2
Examples of applications
280
Lt tfix Øv Øt Ch
= Screw length = Fixture thickness = Screw diameter = Head screw diameter = Spanner
universal and frame fixings
Vorpa VB Universal ligth fixing for plasterboard
perforated cement
hollow brick plasterboard boards and panels
products group
VB M5
VBC M6
VBE M8
VBB M6
VBD M8
To fix • lightings, paintings • ceilings • mirror cabinets • light shelves • pipe clamps • profiles for slabs
product information Characteristics • cavity fixing VBA-VB-VBC-VBE: spring toggle • cavity fixing VBB and VBD: gravity toggle • maximum flexibility • high load-bearing capacity • suitable for pre-positioned installation • when placed in the drill hole, the bearing elements of the gravity and spring toggles independently swing open behind the board • no special installation tool is required
Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data
installation sequence
Examples of applications
281
universal and frame fixings
VBA M4 - VBA A2 M4
Suitable for • gypsum plasterboard and gypsum fibreboards • cavity floor slabs made from bricks and concrete • chipboard • plywood
universal and frame fixings
Vorpa VB Universal ligth fixing for plasterboard
perforated cement
hollow brick plasterboard boards and panels
product code and technical data
P
Ø0
Spring toggle VBA M4 Code
1670 1671 1672 21672 1673
Description
Øv mm
do mm
Sv mm
Sc mm
P mm
Øo mm
VBA M4 SCREW VBA M4 STUD/NUT VBA M4 EYEBOLT VBA M4 EYEBOLT INOX A2 VBA M4 WIRE BOLT
M4 M4 M4 M4 M4
12 12 12 14 12
25 25 25 34 25
50 60 30 55 30
12
12,5 12,5 -
P
universal and frame fixings
Ø0
Spring toggle VB M5 Code
670 671 672 673
Description
Øv mm
do mm
Sv mm
Sc mm
P mm
Øo mm
VB M5 VB M5 VB M5 VB M5
M5 M5 M5 M5
14 14 14 14
27 27 27 27
50 60 30 30
12
15 -
SCREW STUD/NUT EYEBOLT WIRE BOLT
Ø0
P
Spring toggle VBC M6 Code
Description
Øv mm
do mm
Sv mm
Sc mm
P mm
Øo mm
2674 2670 2671 2672 2673
VBC M6 WING TOGGLE VBC M6 SCREW M6 x 80 VBC M6 STUD M6 x 100 VBC M6 EYEBOLT VBC M6 WIRE BOLT
M6 M6 M6 M6
17 17 17 17
30 30 30 30
40 50 25 25
13
14,5 -
P
Ø0
Gravity toggle VBB M6 Code
Description
Øv mm
do mm
Sv mm
Sc mm
P mm
Øo mm
1700 703 700 701 702
VBB M6 WING TOGGLE VBB M6 STUD 4.8 M6 x 100 VBB M6 STUD M6 x 100 VBB M6 EYEBOLT VBB M6 WIRE BOLT
M6 M6 M6 M6
15 15 15 15
75 75 75 75
40 60 30 30
13
14,5 -
282
Ø0 Øv do Sc Sv P
= Eyebolt diameter = Screw diameter = Hole diameter = Thickness of the fixture = Interspace = Passage of the hook
universal and frame fixings
Vorpa VB Universal ligth fixing for plasterboard
perforated cement
hollow brick plasterboard boards and panels
product code and technical data
P
Ø0
Spring toggle VBE M8 Code
Description
Øv mm
do mm
Sv mm
Sc mm
P mm
Øo mm
3674 3670 3671 3672 3673
VBE M8 WING TOGGLE VBE M8 STUD 8.8 M8 x 100 VBE M8 STUD M8 x 100 VBE M8 EYEBOLT VBE M8 WIRE BOLT
M8 M8 M8 M8
20 20 20 20
40 40 40 40
50 50 20 20
10
11,8 -
M10
25
45
Spring toggle VBE M10
5674 VBE M10 WING TOGGLE
P
Ø0 Øv do S c Sv P
Gravity toggle VBD M8 heavy duty fixings Code
Description
4674 VBD M8 WING TOGGLE 4671 VBD M8 STUD M8 x 100 4673 VBC M8 WIRE BOLT
Øv mm
do mm
Sv mm
Sc mm
P mm
M8 M8
20 20
75 75
60 60
16
= Eyebolt diameter = Screw diameter = Hole diameter = Thickness of the fixture = Interspace = Passage of the hook
Examples of applications
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values VB Pull out values in daN Spring toggle with screw Spring toggle with stud/nut Spring toggle with eyebolt * Spring toggle with wirebolt * * Bending moment ** Fixing on metal profiles
VB M4
VB M5
VB M6
VB M8
VB M10
VBD M8
120 120 40 40
230 230 60 60
350 350 100 100
600 600 300 300
800
2000**
283
300
1 daN≃1 kg
universal and frame fixings
Heavy duty loads on metal profiles
universal and frame fixings
Vorpa WING TOGGLE VBF M10 Universal ligth fixing for plasterboard
hollow brick plasterboard boards and panels
products group VBF M10 Art. 5678 with stud, nuts, washers
VBF M10 Art. 5677 wing toggle M10
Suitable for • floors with alveolar core • gypsum fibra • paving in perforated blocks • metal profiling • cavity in general • cavity foor slabs made from bricks and concrete
To fix • countertops • collars for exhaust pipes • heavy ducts • suspended profiles
Test report available
universal and frame fixings
product information Characteristics • steel wing toggle with self-locking folding crosspiece inside the cavity • suitable for fixings on perforated panels, panels of gypsum-fibra, prestressed concrete with alveolar core, corrugated metal profiles, cavities in general • allows the application of very heavy loads • possibility to add other accessories as bolts and eyelets hooks
Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data
installation sequence
Examples of applications
284
universal and frame fixings
Vorpa WING TOGGLE VBF M10 Universal ligth fixing for plasterboard
hollow brick plasterboard boards and panels
product code and technical data
Øv Sv
Thread M10 Sc d0
VBF M10 - Art. 5678 with stud, nuts, washers
VBF M10 - Art. 5677 wing toggle M10
Code
Description
5677 5678
VBF M10 WING TOGGLE VBF M10 STUD M10x120, NUTS, WASHERS
Øv mm
do mm
Sc mm
Sv mm
Lv mm
M10
22
60
90
120
Øv do S c S v Lv
= Screw diameter = Hole diameter = Thickness of the fixture = Interspace = Stud length
universal and frame fixings
Examples of applications
ATTENTION: An appropriate safety factor ≥ 4 should be applied on these values VBF Determination of the mean tensile strength of the tilting anchor on a metal profile
1 daN≃1 kg
1500 daN
Wing toggle M10 VBF
The type of support has an influence on the strength of the steel anchor. The values show in the table refer to the maximum resistance of the product; it is advisable to adopt an appropriate security coefficient. 285
universal and frame fixings
Vorpa WING TOGGLE VBG - VBH M10 Universal ligth fixing for plasterboard
hollow brick plasterboard boards and panels
products group VBG M10 Art. 5676 with stud, nuts, washers
Suitable for • floors with alveolar core • gypsum fibra • paving in perforated blocks • metal profiling • cavity in general • cavity foor slabs made from bricks and concrete
To fix • countertops • collars for exhaust pipes • heavy ducts • suspended profiles • suspended sanitary ware
universal and frame fixings
VBH M10 Art. 5679 for suspended sanitary ware
VBG M10 Art. 5675 wing toggle M10
Test report available
product information Characteristics • steel wing toggle with self-locking folding crosspiece inside the cavity • suitable for fixings on perforated panels, panels of gypsum-fibra, prestressed concrete with alveolar core, corrugated metal profiles, cavities in general • allows the application of very heavy loads • possibility to add other accessories as bolts and eyelets hooks
Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data
installation sequence Wing toggle VBG
Wing toggle VBH
286
universal and frame fixings
Vorpa WING TOGGLE VBG - VBH M10 Universal ligth fixing for plasterboard
hollow brick plasterboard boards and panels
product code and technical data
Øv Sv
Thread M10 Sc d0
VBG M10 - Art. 5676 with stud, nuts, washers
VBH M10 - Art. 5679 for suspended sanitary ware
VBG M10 - Art. 5675 wing toggle M10
Code
Description
5675 5676
VBG M10 WING TOGGLE VBG M10 STUD M10x160, NUTS, WASHERS
Øv mm
do mm
Sc mm
Sv mm
Lv mm
M10
30
80
90
160
Sc
Sv
d0
Code
Description
Øv mm
do mm
Sc mm
Sv mm
Lv mm
5679
VBH STUD M10x180 SANITARY WARE
M10
30
80
90
180 Øv do S c Sv Lv
= Screw diameter = Hole diameter = Thickness of the fixture = Interspace = Stud length
Examples of applications
VBG - VBH M10 Tensile strength of the tilting anchor on a 3 mm metal profile
1 daN≃1 kg
1080 daN
Wing toggle VBG M10
The type of support has an influence on the strength of the steel anchor. It is advisable to adopt an appropriate security factor if used on base material with lower mechanical resistance. Recommanded loads in daN on perforated bricks (doppio UNI)
90 daN
Wing toggle VBH M10
The table shows the permissible load for tension, shear and combined tension and shear load.
287
1 daN≃1 kg
universal and frame fixings
Ø
universal and frame fixings
Vorpa HZB Nylon plug
perforated cement
lightweight concrete
aerated concrete
products group
HZB
Suitable for • perforated cement • lightweight concrete • aerated concrete
To fix • light carpentry • lamps, paintings • post boxes • satellite dishes • wall cupboards • wall mounting for TV and radio • pipe clamps
universal and frame fixings
product information Characteristics • external threaded nylon plug suitable for applications on lightweight concrete blocks (e.g. GASBETON). • easy and quick fixings thanks to the external thread • the fixing’s collar prevents it slipping into the drilled hole • nylon safety and reliability • to be used with chipboard screws, and metrical screws • possible close to edge applications • temperature resistant from -40°C to +80°C
Installation • to be mounted aligned the wall Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation • drill the base material without using roto-percussion
Clean the hole before the installation
installation sequence
Examples of applications
288
universal and frame fixings
Vorpa HZB Nylon plug
perforated cement
lightweight concrete
aerated concrete
product code and technical data
HZB
Code Description
do mm
Lt mm
h1 mm
ch mm
Øv thread mm
Øv screw mm
2766 HZB 10/50 2767 HZB 12/60 2768 HZB 14/70
10 12 14
50 60 70
60 70 80
6 8 10
M6 M8 M10
5,0-6,0 7,0-8,0 9,0-10,0
universal and frame fixings
Lt = Plug length h1 = Min. hole depth do = Hole diameter Tfix = Fixture thickness Øv = Screw diameter ch = Hexagonal socket
Types of materials where the fixing application is possible
ATTENTION: An appropriate safety factor ≥ 3 should be applied on these values HZB Substrate materials Oblique axial pull out values in daN Lightweight concrete
HZB Ø10
HZB Ø12
HZB Ø14
110
170
230
289
1 daN≃1 kg
universal and frame fixings
Vorpa VP HAMMER-IN Nylon plug
concrete
aerated concrete
natural stone
solid brick
wood
products group
VPX PIATTO
VP TL LARGO
*
Suitable for • concrete • aerated concrete • natural stone • solid brick • wood
VP INOX A2 LARGO
To fix • slides • cable and pipe clamps • wall connection or plaster profiles • electrical installations • plumbing, door stops • skirtings, ducts • covering installations
VP ZIP LARGO
universal and frame fixings
VP NERO LARGO
VP RAME LARGO
VP RAMATO
VP G RAME LARGO
A2 INOX 304
* Clean the hole before the installation
installation sequence
Examples of applications
290
universal and frame fixings
Vorpa VP HAMMER-IN Nylon plug
concrete
aerated concrete
natural stone
solid brick
wood
product information Characteristics • hammer-in screw fixing for installations economic series • various versions available • rapid hammerset installation • the integrated hammer-in stop prevents the plug from expanding prematurely • wide range of diameters, usage lengths and head shapes • suitable for push-through installation • when hammered in, the nail screw causes the plug to expand in two directions
Installation • to be mounted aligned the wall Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation
product code and technical data VPX PIATTO with flanged collar Description
dnom x Lt mm
h1 mm
Tfix mm
do mm
ØT mm
598 620 621 627 622 624
VPX 5/27 VPX 5/30 VPX 6/40 VPX 6/50 VPX 6/60 VPX 8/70
5 x 27 5 x 30 6 x 40 6 x 50 6 x 60 8 x 70
30 45 55 65 75 85
1 2 5 15 25 25
5 5 6 6 6 8
9 9 10 10 10 11
VP TL with large flanged collar Code
Description
dnom x Lt mm
h1 mm
Tfix mm
do mm
ØT mm
440 441 425 426 427
VP TL 5/25 VP TL 6/30 VP TL 6/40 VP TL 6/50 VP TL 6/60
5 x 25 6 x 30 6 x 40 6 x 50 8 x 60
40 45 55 65 75
2 2 5 15 25
5 6 6 6 6
10 13 14 14 14
VP INOX A2 SS with large flanged collar and stainless steel screw Code
Description
1741 1742 1743
VP INOX VP INOX VP INOX
6/40 6/50 6/60
universal and frame fixings
Code
Lt = Plug length h1 = Min. hole depth do = Hole diameter Tfix = Fixture thickness dnom = Plug diameter ØT = Head screw diameter
A2 INOX 304
dnom x Lt mm
h1 mm
Tfix mm
do mm
ØT mm
6 x 40 6 x 50 6 x 60
50 60 70
5 15 25
6 6 6
14 14 14
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values Pull out values in daN
1 daN≃1 kg
VP Substrate materials Concrete C20/25 Concrete C20/25 Concrete C20/25
VPX5 90
VPX6 140
VP TL 5 90
VP TL 6 140 VP INOX 6 140
291
VPX8 180
universal and frame fixings
Vorpa VP HAMMER-IN Nylon plug
concrete
aerated concrete
natural stone
solid brick
wood
product code and technical data VP ZIP with flanged collar Code
Description
5740 5741
VP ZIP 5/27 VP ZIP 6/32
dnom x Lt mm
h1 mm
Tfix mm
do mm
ØT mm
5 x 27 6 x 32
35 40
3,5 5,0
5 6
11 13
universal and frame fixings
VP NERO with flanged collar Code
Description
1750 1751 1752 1753
VP NERO VP NERO VP NERO VP NERO
6/30 6/40 6/50 6/60
dnom x Lt mm
h1 mm
Tfix mm
do mm
ØT mm
6 x 30 6 x 40 6 x 50 6 x 60
35 50 60 70
2 5 15 25
6 6 6 6
13 14 14 14
Lt = Plug length h1 = Min. hole depth do = Hole diameter Tfix = Fixture thickness dnom = Plug diameter ØT = Head screw diameter
VP RAME with large flanged collar and copper screw Code
1780 1781 1782 1783
Description
VP RAME VP RAME VP RAME VP RAME
6/30 6/40 6/50 6/60
dnom x Lt mm
h1 mm
Tfix mm
do mm
ØT mm
6 x 30 6 x 40 6 x 50 6 x 60
35 50 60 70
2 5 15 25
6 6 6 6
13 14 14 14
VP RAMATO with copper plated screw
Code
430R 431R 430 431
Description
VP RAMATO 6/40 VP RAMATO 6/60 VPG RAME 6/40 VPG RAME 6/60
VPG RAME with copper screw
dnom x Lt mm
h1 mm
Tfix mm
do mm
ØT mm
6 x 40 6 x 60 6 x 40 6 x 60
50 70 50 70
5 25 5 25
6 6 6 6
14 14 14 14
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values Pull out values in daN
1 daN≃1 kg
VP Substrate materials Concrete C20/25 Solid brick Hollow brick
VP ZIP 5 70 60 50
VP ZIP 6 90 80 50 VP NERO 6 140
Concrete C20/25
VP RAME 6 140 VPG 6 140
Concrete C20/25 Concrete C20/25
292
universal and frame fixings
Vorpa VP ZAMAK Hammer-in zamak preassembling plug
concrete
natural stone
solid brick
wood
products group To fix • slides, cable and pipe clamps • wall connection or plaster profiles • electrical installations • plumbing, door stops • skirtings, ducts • covering installations
Suitable for • concrete • natural stone • solid brick • wood
VP ZAMAK
product information Installation • to be mounted aligned the wall
Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation
Clean the hole before the installation
installation sequence
product code and technical data Code Description
2650 VP ZAMA 6/30 2651 VP ZAMA 6/40 2652 VP ZAMA 6/65
dnom x Lt mm
h1 mm
Tfix mm
do mm
6 x 30 6 x 40 6 x 65
35 50 70
5 15 35
6 6 6
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values
Lt = Anchor length h1 = Min. hole depth do = Hole diameter Tfix = Fixture thickness dnom = Plug diameter
VP ZAMAK Substrate materials Pull out values in daN Concrete C20/25 Solid brick
VP ZAMA Ø6 120 100
293
1 daN≃1 kg
universal and frame fixings
Characteristics • hammer-in preassembled zamak plug • cost-efficient hammerset installation • guarantees minimum movement when under load • high safety in use • the ceiling nail is driven into the drill hole with a hammer until it is firmly in position • at the end of the expansion of the pin against the drill hole wall, the hammer-in zamak plug guarantees protection against burglary and thievery
universal and frame fixings
Vorpa VPO CE Hammer-in nylon fixing with European Technical Assesment for non cracked concrete
concrete
natural stone
solid brick
products group VPO CE countersunk flanged collar
Approved for • non-cracked concrete for fixing of external thermal insulation composite system ETICS-ETAG 014-Cat.A Also suitable for • natural stone • solid brick
To fix • door frames/windows frames • counter frames • wood substructures - profiles • external the thermal insulation profiles • skirtings insulation profiles
ETAG 014 use category A
universal and frame fixings
product information Characteristics • integrated hammer-in nylon plug for push-through installation • nailed-in plastic anchors for fixing of External thermal insulation composite system with rendering in concrete ETAG 014 • easy fast and economical fixing • suitable for substructures made of wood and metal • ideal for an economic series installation • the hammer in plug structure prevents the plug from expanding prematurely • the thread of the nail screw allows the screw to be removed • when hammered in, the nail screw causes the plug to expand in two directions
Installation • through setting anchor Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation
Clean the hole before the installation
installation sequence
Examples of applications
294
universal and frame fixings
Vorpa VPO CE Hammer-in nylon fixing with European Technical Assesment for non cracked concrete
concrete
natural stone
solid brick
product code and technical data VPO CE countersunk flanged collar
Code
Description
4190 4191 4192 4193 4194 4195 4196 4197 4198
VPO CE 6/40 VPO CE 6/50 VPO CE 6/60 VPO CE 6/80 VPO CE 8/60 VPO CE 8/80 VPO CE 8/100 VPO CE 8/120 VPO CE 8/140
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
do mm
hef mm
6 x 40 6 x 50 6 x 60 6 x 80 8 x 60 8 x 80 8 x 100 8 x 120 8 x 140
4 x 45 4 x 65 4 x 85 5 x 50 5 x 65 5 x 85 5 x 105 5 x 125 5 x 145
55 65 75 95 75 95 115 135 155
10 20 30 50 20 40 60 80 100
6 6 6 6 8 8 8 8 8
30 30 30 30 40 40 40 40 40
Examples of applications
ATTENTION: An appropriate safety factor ≥ 3 should be applied on these values on solid brick Non cracked concrete Use category A VPO CE Installation data Minimum spacing Smin Minimum edge distance Cmin Minimum thicknes of the member hmin
1 kN≃100 kg
mm 100 mm 100 mm 100
Characteristic values non-cracked concrete Pull out failure C12/15 C20/25-C50/60
KN KN
Nrk,P Nrk,P
Values where the reduction factor γ is included (Design loads) Pull out failure Nrk,P C12/15 Nrk,P C20/25-C50/60 Recommended loads Pull out failure C12/15 C20/25-C50/60 application on solid brick: not covered by ETA Characteristic values solid brick Pull out failure **solid brick
KN KN
N N
KN KN
KN
295
VPO CE 6
VPO CE 8
0,50 0,75
0,40 0,60
VPO CE 6
VPO CE 8
0,25 0,38
0,20 0,30
VPO CE 6
VPO CE 8
0,16 0,24
0,13 0,20
VPO CE 6
VPO CE 8
0,30
0,20
universal and frame fixings
Lt = Plug length h1 = Min. hole depth do = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length dnom = Plug diameter hef = Embedment depth
universal and frame fixings
Vorpa VPI CE Hammer-in nylon fixing with European Technical Assesment for non cracked concrete
concrete
natural stone
solid brick
products group VPI CE
Approved for • non-cracked concrete for fixing of external thermal insulation composite system ETICS-ETAG 014-Cat.A Also suitable for • natural stone • solid brick
To fix • door frames/windows frames • counter frames • wood substructures - profiles • external the thermal insulation profiles • skirtings insulation profiles
ETAG 014 use category A
universal and frame fixings
product information Characteristics • integrated hammer-in nylon plug for push-through installation • nailed-in plastic anchors for fixing of External thermal insulation composite system with rendering in concrete ETAG 014 • easy fast and economical fixing • suitable for substructures made of wood and metal • ideal for an economic series installation • the hammer in plug structure prevents the plug from expanding prematurely • the thread of the nail screw allows the screw to be removed • when hammered in, the nail screw causes the plug to expand in two directions
Installation • through setting anchor Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation
Clean the hole before the installation
installation sequence
Examples of applications
296
universal and frame fixings
Vorpa VPI CE Hammer-in nylon fixing with European Technical Assesment for non cracked concrete
concrete
natural stone
solid brick
product code and technical data VPI CE
Code
Description
4154 4155 4156 4157 4158 4159 4160 4161 4162
VPI CE 6/40 VPI CE 6/50 VPI CE 6/60 VPI CE 6/80 VPI CE 8/60 VPI CE 8/80 VPI CE 8/100 VPI CE 8/120 VPI CE 8/140
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
do mm
hef mm
6 x 40 6 x 50 6 x 60 6 x 80 8 x 60 8 x 80 8 x 100 8 x 120 8 x 140
4 x 45 4 x 65 4 x 85 5 x 50 5 x 65 5 x 85 5 x 105 5 x 125 5 x 145
55 65 75 95 75 95 115 135 155
10 20 30 50 20 40 60 80 100
6 6 6 6 8 8 8 8 8
30 30 30 30 40 40 40 40 40
hef
Examples of applications
ATTENTION: An appropriate safety factor ≥ 3 should be applied on these values on solid brick Non cracked concrete Use category A VPI CE Installation data Minimum spacing Smin Minimum edge distance Cmin Minimum thicknes of the member hmin
1 kN≃100 kg
mm 100 mm 100 mm 100
Characteristic values non-cracked concrete Pull out failure C12/15 C20/25-C50/60
KN KN
Nrk,P Nrk,P
Values where the reduction factor γ is included (Design loads) Pull out failure Nrk,P C12/15 Nrk,P C20/25-C50/60 Recommended loads Pull out failure C12/15 C20/25-C50/60 application on solid brick: not covered by ETA Characteristic values solid brick Pull out failure **solid brick
KN KN
N N
KN KN
KN
297
VPI CE 6
VPI CE 8
0,50 0,75
0,40 0,60
VPI CE 6
VPI CE 8
0,25 0,38
0,20 0,30
VPI CE 6
VPI CE 8
0,16 0,24
0,13 0,20
VPI CE 6
VPI CE 8
0,30
0,20
universal and frame fixings
Lt = Plug length h1 = Min. hole depth do = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length dnom = Plug diameter hef = Embedment depth
universal and frame fixings
Vorpa VPO Hammer-in nylon fixing
concrete
natural stone
solid brick
products group VPO hammer-in plug countersunk flanged collar
*
Suitable for • non cracked concrete • natural stone • solid brick
VPO INOX A2 SS hammer-in plug countersunk flanged collar
A2 INOX 304
*
To fix • door frames/windows frames • counter frames • wood substructures • profiles, skirtings • electrical installations • wall connection or plaster profiles • slides, sheets • cable and pipe clamps • punched tapes • external wood deck
universal and frame fixings
product information Characteristics • integrated hammer-in nylon plug for push-through installation • easy fast and economical fixing • suitable for substructures made of wood and metal • ideal for an economic series installation • the hammer in plug structure prevents the plug from expanding prematurely • the thread of the nail screw allows the screw to be removed • when hammered in, the nail screw causes the plug to expand in two directions
Installation • through setting anchor Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation
Clean the hole before the installation
installation sequence
Examples of applications
298
universal and frame fixings
Vorpa VPO Hammer-in nylon fixing
concrete
natural stone
solid brick
product code and technical data VPO hammer-in plug countersunk flanged collar
Description
dnom x Lt mm
h1 mm
Tfix mm
do mm
690 662 1663 663 691 1664 664 692 693 694 698 668 699 2950 2951 2952
VPO 5/35 VPO 5/50 VPO 6/40 VPO 6/50 VPO 6/60 VPO 6/70 VPO 6/80 VPO 8/60 VPO 8/80 VPO 8/100 VPO 8/120 VPO 8/135 VPO 10/100 VPO 10/120 VPO 10/140 VPO 10/160
5 x 35 5 x 50 6 x 40 6 x 50 6 x 60 6 x 70 6 x 80 8 x 60 8 x 80 8 x 100 8 x 120 8 x 135 10 x 100 10 x 120 10 x 140 10 x 160
45 60 50 60 70 80 90 70 90 110 130 145 110 130 150 170
5 20 10 20 30 40 50 20 40 60 80 95 60 70 90 100
5 5 6 6 6 6 6 8 8 8 8 8 10 10 10 10
VPO INOX A2 SS hammer-in plug countersunk flanged collar
Code
Description
3643 3644 3645 3646 3647 3648
VPO A2 VPO A2 VPO A2 VPO A2 VPO A2 VPO A2
6/40 6/60 6/80 8/60 8/80 8/100
Lt = Plug length h1 = Min. hole depth do = Hole diameter Tfix = Fixture thickness dnom = Plug diameter
A2 INOX 304
dnom x Lt mm
h1 mm
Tfix mm
do mm
6 x 40 6 x 60 6 x 80 8 x 60 8 x 80 8 x 100
55 75 95 75 95 115
10 30 50 20 40 60
6 6 6 8 8 8
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values on solid brick VPO Substrate materials Pull out values in daN Concrete C20/25 Solid brick
VPO 5
VPO 6
VPO 8
90 80
140 110
180 150
299
VPO 10 1 daN≃1 kg 310 280
universal and frame fixings
Code
universal and frame fixings
Vorpa VPI Hammer-in nylon fixing
concrete
natural stone
solid brick
products group VPI
Suitable for • non cracked concrete • natural stone • solid brick
To fix • door frames/windows frames • counter frames • wood substructures • profiles, skirtings • electrical installations • wall connection or plaster profiles • slides, sheets • cable and pipe clamps • punched tapes
universal and frame fixings
product information Characteristics • integrated hammer-in nylon plug for push-through installation • easy fast and economical fixing • suitable for substructures made of wood and metal • ideal for an economic series installation • the hammer in plug structure prevents the plug from expanding prematurely • the thread of the nail screw allows the screw to be removed • when hammered in, the nail screw causes the plug to expand in two directions
Installation • through setting anchor Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation
Clean the hole before the installation
installation sequence
Examples of applications
300
universal and frame fixings
Vorpa VPI Hammer-in nylon fixing
concrete
natural stone
solid brick
product code and technical data VPI hef
Description
dnom x Lt mm
h1 mm
Tfix mm
do mm
2689 2690N 2626 2663 2691N 2664 2665 2692 2693 2628 2694 2698 2699N
VPI 5/25 VPI 5/30 VPI 5/50 VPI 6/50 VPI 6/60 VPI 6/80 VPI 8/50 VPI 8/60 VPI 8/70 VPI 8/80 VPI 8/100 VPI 8/120 VPI 8/140
5 x 25 5 x 30 5 x 50 6 x 50 6 x 60 6 x 80 8 x 50 8 x 60 8 x 70 8 x 80 8 x 100 8 x 120 8 x 140
35 40 60 60 70 90 60 70 80 90 110 130 150
3 5 20 20 30 50 10 20 30 40 60 80 100
5 5 5 6 6 6 8 8 8 8 8 8 8
Lt = Plug length h1 = Min. hole depth do = Hole diameter Tfix = Fixture thickness dnom = Plug diameter
universal and frame fixings
Code
Examples of applications
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values on solid brick VPI Substrate materials Pull out values in daN Concrete C20/25 Solid brick
VPI 5
VPI 6
VPI 8
90 80
140 110
180 150
301
1 daN≃1 kg
universal and frame fixings
Vorpa VPC CE Multi-purpose nylon fixing with European Technical Assesment for cracked concrete
cracked concrete
solid brick
hollow brick
perforated brick
vulcanic tuff
aerated poroton
products group Approved for • cracked and non-cracked VPC CE TSP concrete C12/15 - C50/60 VPC CE TSP A4 • building materials use category with countersunk head a-b-c-d ETAG 020 screw and Torx recess
To fix • window and door frames • light structural works • wooden substructures • handrail
Also suitable for • solid brick • hollow brick VPC CE TE • perforated brick VPC CE TE A4 • vulcanic tuf with hexagonal head • aerated poroton special wood screw
* * universal and frame fixings
and Torx recess
VPC TC with mushroom head special wood screw and Torx recess
CALCULATION SOFTWARE
ETAG 020 for use categories a-b-c-d
A4 INOX 316
only Ø10
*
product information Characteristics • extra long nylon fixing with countersunk or cylinder edge suitable for applications on compact and hollow materials. Supplied with different types of screws • special anti-rotation wings that prevents the plug turning in the hole on installation • the plug’s neck avoid the introduction of the plug inside the hole • resistant to temperatures from -40°C to +80°C • European Technical Assesment ETAG 020 • temperature resistant from -40°C to + 80°C • fire resistant only Ø10 R90 • the special anti-rotation wings on the nylon sleeve provides easy and safe installation on all types of material, avoiding any rotation of the nylon sleeve while the screw is installed • ideal for fixing of facade, frames and general fastenings
• fully radial expansion behaviour on concrete and solid masonry • multiple radial expansion behaviour on perforated masonry • knotting behaviour on hollow masonry Installation • through setting anchor Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation
Examples of applications
302
universal and frame fixings
Vorpa VPC CE Multi-purpose nylon fixing with European Technical Assesment for cracked concrete
cracked concrete
solid brick
hollow brick
perforated brick
vulcanic tuff
aerated poroton
installation sequence On solid brick
Make a drill hole with a hammer drill
Place the fixture and then Put the anchor by hammering Make sure that the fixture insert the anchor into the hole softly on the screw head until is supported by the anchor the fixture stops the nylon (nylon plug and screw) plug
Clean the hole
Place the fixture and the anchor into the hole by hand
On hollow brick
Make a drill hole just by rotary drilling
Clean the hole before the installation
Put the anchor by hammering softly on the screw head until the fixture stops the nylon plug
product code and technical data
VPC CE TSP with countersunk head screw and Torx recess Code
Description
6100 6101 6102 6103 6104 6105 6106 6107 6108 6109 6110
* * * * * * *
VPC TSP VPC TSP VPC TSP VPC TSP VPC TSP VPC TSP VPC TSP VPC TSP VPC TSP VPC TSP VPC TSP
* * * * * * *
VPC TSP INOX A4 8/80 VPC TSP INOX A4 8/100 VPC TSP INOX A4 8/120 VPC TSP INOX A4 8/140 VPC TSP INOX A4 10/80 VPC TSP INOX A4 10/100 VPC TSP INOX A4 10/120 VPC TSP INOX A4 10/140 VPC TSP INOX A4 10/160 VPC TSP INOX A4 10/200 VPC TSP INOX A4 10/230
6196 6197 6198 6199 6200 6201 6202 6203 6204 6205 6206
8/80 8/100 8/120 8/140 10/80 10/100 10/120 10/140 10/160 10/200 10/230
*
VPC CE TSP A4 with A4 SS countersunk head screw and Torx recess
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
do mm
hef mm
df mm
T
8x80 8x100 8x120 8x140 10x80 10x100 10x120 10x140 10x160 10x200 10x230
6x85 6x105 6x125 6x145 7x85 7x105 7x125 7x145 7x165 7x205 7x235
90 90 90 90 90 90 90 90 90 90 90
10 30 50 70 10 30 50 70 90 130 160
8 8 8 8 10 10 10 10 10 10 10
70 70 70 70 70 70 70 70 70 70 70
9 9 9 9 11 11 11 11 11 11 11
TX30 TX30 TX30 TX30 TX40 TX40 TX40 TX40 TX40 TX40 TX40
8x80 8x100 8x120 8x140 10x80 10x100 10x120 10x140 10x160 10x200 10x230
6x85 6x105 6x125 6x145 7x85 7x105 7x125 7x145 7x165 7x205 7x235
90 90 90 90 90 90 90 90 90 90 90
10 30 50 70 10 30 50 70 90 130 160
8 8 8 8 10 10 10 10 10 10 10
70 70 70 70 70 70 70 70 70 70 70
9 9 9 9 11 11 11 11 11 11 11
TX30 TX30 TX30 TX30 TX40 TX40 TX40 TX40 TX40 TX40 TX40
* VPC CE Ø10: at least 90 minutes fire resistance (R90) for fastening of façade systems on concrete, if the admissible load ≤0,8 [kN] (no permanent centric tension load).
303
Sent the screw by screw driver or by hand. Make sure that the fixture is supported by the anchor (nylon plug and screw)
A4 INOX 316
*
Lt = Plug length h1 = Min. hole depth do = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Diameter hole in the fixture dnom = Plug diameter hef = Embedment depth
universal and frame fixings
Clean the hole
universal and frame fixings
Vorpa VPC CE Multi-purpose nylon fixing with European Technical Assesment for cracked concrete
cracked concrete
solid brick
hollow brick
perforated brick
vulcanic tuff
aerated poroton
product code and technical data
universal and frame fixings
VPC CE TE * VPC CE TE A4 INOX A4 with A4 SS hexagonal head with hexagonal head special special wood screw and Torx wood screw and Torx recess recess Code
Description
6112 6113 6114 6115 6116 6117 6118 6119 6120 6121 6122
* * * * * * *
VPC TE VPC TE VPC TE VPC TE VPC TE VPC TE VPC TE VPC TE VPC TE VPC TE VPC TE
* * * * * * *
VPC TE INOX A4 8/80 VPC TE INOX A4 8/100 VPC TE INOX A4 8/120 VPC TE INOX A4 8/140 VPC TE INOX A4 10/80 VPC TE INOX A4 10/100 VPC TE INOX A4 10/120 VPC TE INOX A4 10/140 VPC TE INOX A4 10/160 VPC TE INOX A4 10/200 VPC TE INOX A4 10/230
6184 6185 6186 6187 6188 6189 6190 6191 6192 6193 6194
8/80 8/100 8/120 8/140 10/80 10/100 10/120 10/140 10/160 10/200 10/230
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
do mm
hef df mm mm
Ch
T
8x80 8x100 8x120 8x140 10x80 10x100 10x120 10x140 10x160 10x200 10x230
6x85 6x105 6x125 6x145 7x85 7x105 7x125 7x145 7x165 7x205 7x235
90 90 90 90 90 90 90 90 90 90 90
10 30 50 70 10 30 50 70 90 130 160
8 8 8 8 10 10 10 10 10 10 10
70 70 70 70 70 70 70 70 70 70 70
9 9 9 9 11 11 11 11 11 11 11
10 10 10 10 13 13 13 13 13 13 13
TX30 TX30 TX30 TX30 TX40 TX40 TX40 TX40 TX40 TX40 TX40
8x80 8x100 8x120 8x140 10x80 10x100 10x120 10x140 10x160 10x200 10x230
6x85 6x105 6x125 6x145 7x85 7x105 7x125 7x145 7x165 7x205 7x235
90 90 90 90 90 90 90 90 90 90 90
10 30 50 70 10 30 50 70 90 130 160
8 8 8 8 10 10 10 10 10 10 10
70 70 70 70 70 70 70 70 70 70 70
9 9 9 9 11 11 11 11 11 11 11
10 10 10 10 13 13 13 13 13 13 13
TX30 TX30 TX30 TX30 TX40 TX40 TX40 TX40 TX40 TX40 TX40
A4 INOX 316
*
* VPC CE Ø10: at least 90 minutes fire resistance (R90) for fastening of façade systems on concrete, if the admissible load ≤0,8 [kN] (no permanent centric tension load).
VPC TC with mushroom head special wood screw and Torx recess Code
Description
6124 6125 6126 6127 6128 6129 6130 6131 6132 6133
VPC TC 8/80 VPC TC 8/100 VPC TC 8/120 VPC TC 8/140 VPC TC 10/80 VPC TC 10/100 VPC TC 10/120 VPC TC 10/140 VPC TC 10/160 VPC TC 10/200
* * * * *
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
do mm
hef df mm mm
8x80 8x100 8x120 8x140 10x80 10x100 10x120 10x140 10x160 10x200
6x85 6x105 6x125 6x145 7x85 7x105 7x125 7x145 7x165 7x205
90 90 90 90 90 90 90 90 90 90
10 30 50 70 10 30 50 70 90 130
8 8 8 8 10 10 10 10 10 10
70 70 70 70 70 70 70 70 70 70
9 9 9 9 11 11 11 11 11 11
T
TX30 TX30 TX30 TX30 TX40 TX40 TX40 TX40 TX40 TX40
* VPC CE Ø10: at least 90 minutes fire resistance (R90) for fastening of façade systems on concrete, if the admissible load ≤0,8 [kN] (no permanent centric tension load).
304
Lt = Plug length h1 = Min. hole depth do = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Diameter hole in the fixture dnom = Plug diameter hef = Embedment depth
universal and frame fixings
Vorpa VPC CE Multi-purpose nylon fixing with European Technical Assesment for cracked concrete
cracked concrete
solid brick
hollow brick
perforated brick
vulcanic tuff
aerated poroton
technical data
Use Category “a”
Use Category “d”
Cracked and non-cracked concrete C16/20
Autoclaved aerated concrete Density 0.5 Kg/dm3 Min.Compression strenght 3.5 N/mm2
Installation data Minimum spacing Smin Minimum edge distance Cmin Minimum thicknes of the member hmin
mm mm mm
VPC Ø8 90 90 140
VPC Ø10 100 100 140
Pull out characteristic values VPC Temperature range T Characteristic resistance NRK,p
VPC Ø8 VPC Ø10 °C 24-40 50-80 24-40 50-80 kN 3.5 3.0 4.5 4.0
Installation data Single anchor Minimum edge distance Group of anchors Minimum spacing (perpendicular to free edge) Minimum spacing (parallel to free edge) Minimum edge distance Minimum thicknes of the member Pull out characteristic values VPC Characteristic resistance
VPC Ø8
VPC Ø10
mm
240
240
S1min mm
120
120
S2min mm
240
240
Cmin hmin
480 120
480 120
VPC Ø8 0.5
VPC Ø8 0.6
Cmin
mm mm
NRK,p kN
Use Category “b” - Paragraph 2
A - Solid masonry 110x60x240 “Danesi” Density 1.7 Kg/dm3 Min.Compression strenght 39 N/mm2
B - Solid masonry 250x120x55 “Terreal Italia” Density 1.7 Kg/dm3 Min.Compression strenght 27 N/mm2
Installation data Single anchor Minimum edge distance Group of anchors Minimum edge distance Minimum spacing (perpendicular to free edge) Minimum spacing (parallel to free edge) Minimum thicknes of the member Pull out characteristic values VPC Characteristic resistance
VPC Ø8
VPC Ø10
Cmin
mm
120
120
Cmin S1min
mm mm
120 240
120 240
S2min
mm
480
480
hmin
mm
110
110
Installation data Single anchor Minimum edge distance Group of anchors Minimum edge distance Minimum spacing (perpendicular to free edge) Minimum spacing (parallel to free edge) Minimum thicknes of the member
NRK,p
kN
VPC Ø8 3.0
VPC Ø10 2.0
Pull out characteristic values VPC Characteristic resistance
universal and frame fixings
Use Category “b” - Paragraph 1
VPC Ø8
VPC Ø10
Cmin
mm
120
120
Cmin S1min
mm mm
125 250
125 250
S2min
mm
500
500
hmin
mm
120
120
NRK,p
kN
VPC Ø8 4.0
VPC Ø10 5.0
Use Category “b” - Paragraph 3
Use Category “b” - Paragraph 4
E - Fine tuff 370x370x110 “Cave riunite” Density 2.4 Kg/dm3 Min.Compression strenght 7.5 N/mm2
F - Calcium silicate KS-R(P)-202.0 - 8DF (240) “Heidelberg - Kalksandstein Density 1.9 Kg/dm3 Min.Compression strenght 28.2 N/mm2)
Installation data Single anchor Minimum edge distance Group of anchors Minimum edge distance Minimum spacing (perpendicular to free edge) Minimum spacing (parallel to free edge) Minimum thicknes of the member
VPC Ø8 VPC Ø10 Cmin
mm
185
185
Cmin S1min
mm mm
185 370
185 370
S2min
mm
740
740
hmin
mm
370
370
Pull out characteristic values VPC Characteristic resistance
NRK,p
kN
Installation data Single anchor Minimum edge distance Group of anchors Minimum edge distance Minimum spacing (perpendicular to free edge) Minimum spacing (parallel to free edge) Minimum thicknes of the member
VPC Ø8 VPC Ø10 0.3
Pull out characteristic values VPC Characteristic resistance
305
VPC Ø8
VPC Ø10
Cmin
mm
120
120
S1min
mm
240
240
S2min
mm
480
480
Cmin hmin
mm mm
120 240
120 240
NRK,p
kN
VPC Ø8 5.5
VPC Ø10 6.0
universal and frame fixings
Vorpa VPC CE Multi-purpose nylon fixing with European Technical Assesment for cracked concrete
cracked concrete
solid brick
hollow brick
perforated brick
vulcanic tuff
aerated poroton
Use Category “c” - Paragraph 5
Use Category “c” - Paragraph 6
C - Doppio UNI 120x245x250 “Danesi” Density 0.9 Kg/dm3 Min.Compression strenght 13 N/mm2
D - Hollow brick 120x250x250 “Wienerberger” Density 0.6 Kg/dm3 Min.Compression strenght 2,0 N/mm2
Installation data Single anchor Minimum edge distance Group of anchors Minimum edge distance Minimum spacing (perpendicular to free edge) Minimum spacing (parallel to free edge) Minimum thicknes of the member
VPC Ø8
VPC Ø10
mm
125
125
Cmin mm S1min mm
125 250
125 250
S2min mm
500
500
mm
120
120
Installation data Single anchor Minimum edge distance Group of anchors Minimum edge distance Minimum spacing (perpendicular to free edge) Minimum spacing (parallel to free edge) Minimum thicknes of the member
VPC Ø8 -
VPC Ø10 0.3
Pull out characteristic values VPC Characteristic resistance
Cmin
hmin
Pull out characteristic values VPC Characteristic resistance
NRK,p kN
VPC Ø8
VPC Ø10
mm
125
125
Cmin mm S1min mm
75 250
75 250
S2min mm
500
500
hmin
120
120
VPC Ø8 0.3
VPC Ø10 -
Cmin
mm
NRK,p kN
Use Category “c” - Paragraph 7
Use Category “c” - Paragraph 8
G - Poroton T-24,0-0,9 “Wieneberger” Density 0.9 Kg/dm3 Min.Compression strenght 7.0 N/mm2
H - Poroton HIZB - ZDF - 0.9 “Wieneberger” Density 0.9 Kg/dm3 Min.Compression strenght 16:4 N/mm2
500
235 15
10 15
10
35
25
110
5
235
universal and frame fixings
technical data
10 18
15
Installation data Single anchor Minimum edge distance Group of anchors Minimum spacing (perpendicular to free edge) Minimum spacing (parallel to free edge) Minimum edge distance Minimum thicknes of the member Pull out characteristic values VPC Characteristic resistance
VPC Ø8
VPC Ø10
mm
120
120
S1min mm
240
240
S2min mm
480
480
Cmin hmin
120 240
120 240
Installation data Single anchor Minimum edge distance Anchor Group Minimum spacing (perpendicular to free edge) Minimum spacing (parallel to free edge) Minimum edge distance Minimum thicknes of the member
VPC Ø8 0.9
VPC Ø10 0.9
Pull out characteristic values VPC Characteristic resistance
Cmin
mm mm
NRK,p kN
306
VPC Ø8
VPC Ø10
Cmin mm
120
120
S1min mm
240
240
S2min mm
480
480
Cmin mm hmin mm
120 115
120 115
NRK,p kN
VPC Ø8 0.9
VPC Ø10 0:9
universal and frame fixings
Vorpa VPC CE Multi-purpose nylon fixing with European Technical Assesment for cracked concrete
cracked concrete
solid brick
hollow brick
perforated brick
vulcanic tuff
aerated poroton
technical data
Use Category “c” - Paragraph 9 I - Hollow calcium silicate brick KF-L “Heidelberger - Kalksanstein” Density 1.5 Kg/dm3 Min.Compression strenght 16.3 N/mm2
240 30
25
175
35 10
21
25 28
38
Pull out characteristic values VPC Characteristic resistance
Use categories a b Paragraph 1 Paragraph 2 Paragraph 3 Paragraph 4 c Paragraph 5 Paragraph 6 Paragraph 7 Paragraph 8 Paragraph 9 d
Subcategories A B E F C D G H I
solid brick 39 N/mm2 solid brick 27 N/mm2 fine tuff 7,5 N/mm2 calcium silicate K-SR (P) 28,2 N/mm2 doppio UNI 13 N/mm2 hollow brick 2 N/mm2 poroton 7 N/mm2 poroton 16.4 N/mm2 Hollow calcium silicate brick 16.3 N/mm2
VPC Ø8
VPC Ø10
Cmin
mm
120
120
S1min
mm
240
240
S2min
mm
480
480
Cmin hmin
mm mm
120 175
120 175
NRK,p
kN
VPC Ø8 5.0
VPC Ø8 5.5
Substrates Concrete C12/15 - C50/60 cracked and non cracked
Autoclaved aerated concrete AAC 3,5 N/mm2
Examples of applications
307
universal and frame fixings
Installation data Single anchor Minimum edge distance Group of anchors Minimum spacing (perpendicular to free edge) Minimum spacing (parallel to free edge) Minimum edge distance Minimum thicknes of the member
universal and frame fixings
Vorpa MFR CE Multi-purpose nylon fixing with European Technical Assesment for cracked concrete
cracked concrete
solid brick
hollow brick
perforated brick
products group Approved for • cracked and non-cracked MFR CE TSP concrete C12/15 - C50/60 with countersunk head screw and Torx recess • building materials use category a-b-c-d ETAG 020
To fix • window and door frames • light structural works • wooden substructures • handrail
Also suitable for • solid brick • hollow brick MFR CE TE • perforated brick with hexagonal head • aerated poroton special wood screw
universal and frame fixings
and Torx recess
CALCULATION SOFTWARE
ETAG 020 for use categories a-b-c-d
product information Characteristics • extra long nylon fixing suitable for applications on compact and hollow materials. Supplied with different types of screws • special anti-rotation wings that prevents the plug turning in the hole on installation • the plug’s neck avoid the introduction of the plug inside the hole • resistant to temperatures from -40°C to +80°C • European Technical Assesment ETAG 020 • temperature resistant from -40°C to + 80°C • the special anti-rotation wings on the nylon sleeve provides easy and safe installation on all types of material, avoiding any rotation of the nylon sleeve while the screw is installed • ideal for fixing of facade, frames and general fastenings
Installation • through setting anchor Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation
Examples of applications
308
aerated concrete
universal and frame fixings
Vorpa MFR CE Multi-purpose nylon fixing with European Technical Assesment for cracked concrete
cracked concrete
solid brick
hollow brick
perforated brick
aerated concrete
installation sequence On solid brick
Make a drill hole with a hammer drill
Place the fixture and then Put the anchor by hammering Make sure that the fixture insert the anchor into the hole softly on the screw head until is supported by the anchor the fixture stops the nylon (nylon plug and screw) plug
Clean the hole
Place the fixture and the anchor into the hole by hand
On hollow brick
Make a drill hole just by rotary drilling
Put the anchor by hammering softly on the screw head until the fixture stops the nylon plug
Clean the hole before the installation
product code and technical data
Sent the screw by screw driver or by hand. Make sure that the fixture is supported by the anchor (nylon plug and screw)
MFR CE TSP with countersunk head screw and Torx recess h ef
Code
Description
7860 7861 7862 7863 7864
MFR TSP 14/110 MFR TSP 14/140 MFR TSP 14/170 MFR TSP 14/200 MFR TSP 14/230
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
do mm
hef mm
df mm
Torx
14x110 14x140 14x170 14x200 14x230
10x115 10x145 10x175 10x205 10x235
80 80 80 80 80
40 70 100 130 160
14 14 14 14 14
70 70 70 70 70
15 15 15 15 15
50 50 50 50 50
MFR CE TE with hexagonal head special wood screw and Torx recess Code
Description
7870 7871 7872 7873 7874
MFR TE 14/110 MFR TE 14/140 MFR TE 14/170 MFR TE 14/200 MFR TE 14/230
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
do mm
hef mm
df mm
Ch
Torx
14x110 14x140 14x170 14x200 14x230
10x115 10x145 10x175 10x205 10x235
80 80 80 80 80
40 70 100 130 160
14 14 14 14 14
70 70 70 70 70
15 15 15 15 15
17 17 17 17 17
50 50 50 50 50
309
Lt = Plug length h1 = Min. hole depth do = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Diameter hole in the fixture dnom = Plug diameter hef = Embedment depth Ch = Spanner
universal and frame fixings
Clean the hole
universal and frame fixings
Vorpa MFR CE Multi-purpose nylon fixing with European Technical Assesment for cracked concrete
cracked concrete
solid brick
hollow brick
perforated brick
aerated concrete
technical data
Use category “a”
Use category “b”
Cracked and non-cracked concrete C16/20 - C12/15
1) Solid brick 115x240x71 Density ≥1.8 Kg/dm3 Min.compression strenght ≥ 20 N/mm2
universal and frame fixings
2) Solid brick 116x240x71 Density ≥1.8 Kg/dm3 Min.compression strenght ≥ 10 < 20 N/mm2 Installation data Minimum spacing Smin Minimum edge distance Cmin Minimum thicknes of the member hmin
mm mm mm
≥ C16/20 100 100 120
C12/15 140 140 120
Pull out characteristic values Temperature range T Characteristic resistance NRK,p
≥ C16/20 C12/15 °C 24-40 50-80 24-40 50-80 kN 4.5 3.0 3.0 2.0
Installation data Single anchor Minimum edge distance Group of anchors Minimum edge distance Minimum spacing (perpendicular to free edge) Minimum spacing (parallel to free edge) Minimum thicknes of the member Pull out characteristic values Characteristic resistance
≥ C16/20
C12/15
Cmin mm
100
-
S1min mm
100 200
-
400
-
115
-
S2min mm Cmin mm hmin mm
24/40°C 50/80°C NRK,p kN 1) 4.5 - 2) 3.0 1) 3.0 - 2) 2.0
Use category “b”
Use category “b”
1) Hollow sand-lime brick 250x240x237 Density ≥ 1.8 Kg/dm3 Min.compression strenght ≥ 20 N/mm2
1) Hollow sand-lime brick 240x115x113 Density ≥ 1.8 Kg/dm3 Min.compression strenght ≥ 20 N/mm2
2) Hollow sand-lime brick 250x240x237 Density ≥ 1.8 Kg/dm3 Min.compression strenght ≥ 10 < 20 N/mm2
2) Hollow sand-lime brick 240x115x113 Density ≥ 1.8 Kg/dm3 Min.compression strenght ≥ 10 < 20 N/mm2
Installation data Single anchor Minimum edge distance Group of anchors Minimum edge distance Minimum spacing (perpendicular to free edge) Minimum spacing (parallel to free edge) Minimum thicknes of the member Pull out characteristic values Characteristic resistance
≥ C16/20
C12/15
mm
100
-
Cmin mm S1min mm
100 200
-
S2min mm
400
-
hmin
mm
240
-
NRK,p
24/40°C 50/80°C kN 1) 5.0 - 2) 3.5 1) 4.5 - 2) 3.0
Cmin
Installation data Single anchor Cmin Minimum edge distance Group of anchors Cmin Minimum edge distance S1min Minimum spacing (perpendicular to free edge) S2min Minimum spacing (parallel to free edge) Minimum thicknes of the memberhmin Pull out characteristic values Characteristic resistance
310
NRK,p
≥ C16/20
C12/15
mm
100
-
mm mm
100 200
-
mm
400
-
mm
115
-
kN
24/40°C 50/80°C 1) 4.5 - 2) 3.0 1) 4.0 - 2) 2.5
universal and frame fixings
Vorpa MFR CE Multi-purpose nylon fixing with European Technical Assesment for cracked concrete
cracked concrete
solid brick
hollow brick
perforated brick
aerated concrete
technical data
Use category “c”
Use category “c”
Hollow brick 235x115x113 Density ≥ 1.0 Kg/dm3 Min.compression strenght 12 N/mm2
Hollow brick 250x240x237 Density ≥ 1.4 Kg/dm3 Min.compression strenght 12 N/mm2
Installation data Single anchor Minimum edge distance Group of anchors Minimum edge distance Minimum spacing (perpendicular to free edge) Minimum spacing (parallel to free edge) Minimum thicknes of the member Pull out characteristic values Characteristic resistance
MFR 14 Cmin mm
120
S1min mm
120 240
S2min mm 480 Cmin mm hmin mm
115
NRK,p kN
24/40°C 50/80°C 0.75 0.5
Installation data Single anchor Minimum edge distance Group of anchors Minimum edge distance Minimum spacing (perpendicular to free edge) Minimum spacing (parallel to free edge) Minimum thicknes of the member Pull out characteristic values Characteristic resistance
Cmin mm
100
S1min mm
100 200
S2min mm 400 Cmin mm hmin mm
NRK,p kN
240 24/40°C 50/80°C 1.2 0.75
universal and frame fixings
Use category “d” Non-cracked aerated concrete Density 0.35 Kg/dm3
Installation data Single anchor Minimum edge distance Group of anchors Minimum spacing (perpendicular to free edge) Minimum spacing (parallel to free edge) Minimum thicknes of the member
MFR 14
AAC 2
AAC 4
AAC 6
Cmin
mm
50
75
150
S1min
mm
100
150
200
S2min
mm
200
300
400
hmin
mm
100
100
100
Pull out characteristic values 24/40°C- 50/80°C Characteristic resistance NRK,p kN 0.4 0.3
24/40°C - 50/80°C 24/40°C - 50/80°C 1.2 0.9 2.0 1.5
Examples of applications
311
universal and frame fixings
Vorpa VP R8 Multi-purpose nylon fixing for frame and light carpentry
concrete
natural stone
solid brick
perforated brick
products group VP R8 no accessories
Suitable for • concrete • natural stone • solid brick • perforated brick
VP R8 TE with hexagonal bolt screw
To fix • light carpentry • wood coatings • handrails • wood substructures • door frames • window frames • counter frames
universal and frame fixings
VP R8 TSP with chipboard screw and Torx recess
product information Characteristics • nylon plug for frames and light carpentry • guarantees a simple installation • wide range of applications • suitable for push-through installation • plug with special anti-rotation wings • the higher lenght allows the anchor to contain the entire thickness of the element to be fastened
Installation • through setting anchor Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation
Clean the hole before the installation
installation sequence On solid brick
Make a drill hole with a hammer drill
Clean the hole
Place the fixture and then Put the anchor by hammering Make sure that the fixture insert the anchor into the hole softly on the screw head until is supported by the anchor the fixture stops the nylon (nylon plug and screw) plug
Clean the hole
Place the fixture and the anchor into the hole by hand
On hollow brick
Make a drill hole just by rotary drilling
312
Put the anchor by hammering softly on the screw head until the fixture stops the nylon plug
Sent the screw by screw driver or by hand. Make sure that the fixture is supported by the anchor (nylon plug and screw)
universal and frame fixings
Vorpa VP R8 Multi-purpose nylon fixing for frame and light carpentry
concrete
natural stone
solid brick
perforated brick
product code and technical data VP R8 no accessories
Code
51386 51387 1571 1572 830S 586 51384 51385 51389
Description
VP R8 VP R8 VP R8 VP R8 VP R8 VP R8 VP R8 VP R8 VP R8
10/240 10/280 12/200 12/240 16/140 16/160 16/200 16/240 16/300
dnom x Lt mm
per viti mm
h1 mm
Tfix mm
hef mm
df mm
do mm
10x240 10x280 12x200 12x240 16x140 16x160 16x200 16x240 16x300
7 7 10 10 12 12 12 12 12
255 295 215 255 155 175 215 255 320
140 180 100 140 40 60 100 140 200
100 100 100 100 100 100 100 100 100
11 11 13 13 17 17 17 17 17
10 10 12 12 16 16 16 16 16
VP R8 TE with hexagonal bolt screw
Screw length calculation: Lv > Lt + Tfix
Code
52395 52396 1387 1388 1382 1383 1384 1385 52397
Description
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
hef mm
df mm
do mm
Ch mm
VP R8 TE VP R8 TE VP R8 TE VP R8 TE VP R8 TE VP R8 TE VP R8 TE VP R8 TE VP R8 TE
10x240 10x280 12x200 12x240 16x140 16x160 16x200 16x240 16x300
7x245 7x285 10x200 10x240 12x140 12x160 12x200 12x240 12x300
255 295 215 255 155 175 215 255 320
140 180 100 140 40 60 100 140 200
100 100 100 100 100 100 100 100 100
11 11 13 13 17 17 17 17 17
10 10 12 12 16 16 16 16 16
13 13 17 17 19 19 19 19 19
10/240 10/280 12/200 12/240 16/140 16/160 16/200 16/240 16/300
VP R8 TSP with chipboard screw and Torx recess Code
51395 51396
Description
VP R8 TSP 10/240 VP R8 TSP 10/280
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
hef mm
df mm
do mm
10x240 10x280
7x245 7x285
255 295
140 180
100 100
11 11
10 10
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values VP R8 Substrate materials Pull out values in daN Concrete C20/25 Solid brick Double brick UNI with plaster
VP R8 Ø10
VP R8 Ø12
VP R8 Ø 16
480 380 300
680 400 300
820 480
313
1 daN≃1 kg
universal and frame fixings
Lt = Plug length h1 = Min. hole depth do = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Hole diameter in the fixture dnom = Plug diameter hef = Effective anchorage depth Ch = Spanner
universal and frame fixings
Vorpa VP R6 Multi-purpose nylon fixing for frame and light carpentry
concrete
natural stone
solid brick
products group Suitable for • concrete • natural stone • solid brick • perforated brick
VP R6 no accessories
VP R6 E with chipboard screw
*
To fix • light carpentry • wood coatings • handrails • wood substructures • door frames • window frames • counter frames
VP R6 ET - VP R6 I INOX A2 * with chipboard screw and Torx recess
universal and frame fixings
VP R6 Z with 5.8 hexagonal bolt screw
VP R6 VS with safety Torx recess screw
* ETAG 020 for use categories a-b-c-d
A2 INOX 304
*
product information Characteristics • nylon plug for frames and light carpentry • guarantees a simple installation • wide range of applications • suitable for push-through installation • plug with special anti-rotation wings • the higher lenght allows the anchor to contain the entire thickness of the element to be fastened
Installation • through setting anchor Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation
Examples of applications
314
perforated brick
universal and frame fixings
Vorpa VP R6 Multi-purpose nylon fixing for frame and light carpentry
concrete
natural stone
solid brick
perforated brick
installation sequence On solid brick
Make a drill hole with a hammer drill
Place the fixture and then Put the anchor by hammering Make sure that the fixture insert the anchor into the hole softly on the screw head until is supported by the anchor the fixture stops the nylon (nylon plug and screw) plug
Clean the hole
Place the fixture and the anchor into the hole by hand
On hollow brick
Make a drill hole just by rotary drilling
Clean the hole before the installation
Put the anchor by hammering softly on the screw head until the fixture stops the nylon plug
Sent the screw by screw driver or by hand. Make sure that the fixture is supported by the anchor (nylon plug and screw)
product code and technical data VP R6 no accessories
Code
Description
565 520 1564 566 568 569 570 567 1568
VP R6 8/80 VP R6 8/100 VP R6 8/120 VP R6 10/80 VP R6 10/100 VP R6 10/115 VP R6 10/135 VP R6 10/160 VP R6 10/200
dnom x Lt mm
per viti mm
h1 mm
Tfix mm
do mm
hef mm
df mm
8x80 8x100 8x120 10x80 10x100 10x115 10x135 10x160 10x200
5,5 5,5 5,5 7 7 7 7 7 7
90 110 130 90 110 125 145 170 210
10 30 50 10 30 45 65 90 130
8 8 8 10 10 10 10 10 10
70 70 70 70 70 70 70 70 70
8 8 8 10 10 10 10 10 10
Screw length calculation: Lv > Lt + Tfix
VP R6 VS with safety Torx recess screw
Code
Description
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
do mm
hef mm
df mm
1390 1391 1392 1393 1994 1995
VP R6 VS VP R6 VS VP R6 VS VP R6 VS VP R6 VS VP R6 VS
10x80 10x100 10x115 10x135 10x160 10x200
7x90 7x105 7x120 7x140 7x165 7x205
105 115 125 145 170 210
10 30 45 65 90 130
10 10 10 10 10 10
70 70 70 70 70 70
10 10 10 10 10 10
10/80 TX40 10/100 TX40 10/115 TX40 10/135 TX40 10/160 TX40 10/200 TX40
315
Lt = Plug length h1 = Min. hole depth do = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Hole diameter in the fixture dnom = Plug diameter hef = Effective anchorage depth Ch = Spanner
universal and frame fixings
Clean the hole
universal and frame fixings
Vorpa VP R6 Multi-purpose nylon fixing for frame and light carpentry
concrete
natural stone
solid brick
perforated brick
product code and technical data
VP R6 E with chipboard screw Description
1283 289 1284 1285 285 286 287 288 303
VP R6 E VP R6 E VP R6 E VP R6 E VP R6 E VP R6 E VP R6 E VP R6 E VP R6 E
8/80 8/100 8/120 10/80 10/100 10/115 10/135 10/160 10/200
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
do mm
hef mm
df mm
8x80 8x100 8x120 10x80 10x100 10x115 10x135 10x160 10x200
5,5x85 5,5x105 5,5x125 7x85 7x105 7x120 7x140 7x165 7x205
90 110 130 90 110 125 145 170 210
10 30 50 10 30 45 65 90 130
8 8 8 10 10 10 10 10 10
70 70 70 70 70 70 70 70 70
8 8 8 10 10 10 10 10 10
universal and frame fixings
Code
Lt = Plug length h1 = Min. hole depth do = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Hole diameter in the fixture dnom = Plug diameter hef = Effective anchorage depth Ch = Spanner Screw length calculation: Lv > Lt + Tfix
VP R6 ET with chipboard screw and Torx recess Code
Description
1287 1288 1289 1290 1291 1292 1293 1294 1295
VP R6 ET 8/80 TX30 VP R6 ET 8/100 TX30 VP R6 ET 8/120 TX30 VP R6 ET 10/80 TX40 VP R6 ET 10/100 TX40 VP R6 ET 10/115 TX40 VP R6 ET 10/135 TX40 VP R6 ET 10/160 TX40 VP R6 ET 10/200 TX40
*
VP R6 I INOX A2 with A2 SS chipboard screw and Torx recess
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
do mm
hef mm
df mm
8x80 8x100 8x120 10x80 10x100 10x115 10x135 10x160 10x200
5,5x85 5,5x105 5,5x125 7x85 7x105 7x120 7x140 7x165 7x205
90 110 130 90 110 125 145 170 210
10 30 50 10 30 45 65 90 130
8 8 8 10 10 10 10 10 10
70 70 70 70 70 70 70 70 70
8 8 8 10 10 10 10 10 10
* 10000 10001 10002 10003 10004 10005 10006 10007
VP R6 I A2 8/80 TX30 VP R6 I A2 8/100 TX30 VP R6 I A2 8/120 TX30 VP R6 I A2 10/80 TX40 VP R6 I A2 10/100 TX40 VP R6 I A2 10/115 TX40 VP R6 I A2 10/135 TX40 VP R6 I A2 10/160 TX40
8x80 8x100 8x120 10x80 10x100 10x115 10x135 10x160
5,5x85 5,5x105 5,5x125 7x85 7x105 7x120 7x140 7x165
90 110 130 90 110 125 145 170
10 30 50 10 30 45 65 90
316
8 8 8 10 10 10 10 10
70 70 70 70 70 70 70 70
8 8 8 10 10 10 10 10
A2 INOX 304
universal and frame fixings
Vorpa VP R6 Multi-purpose nylon fixing for frame and light carpentry
concrete
natural stone
solid brick
perforated brick
product code and technical data
VP R6 Z with 5.8 hexagonal bolt screw
Code
Description
1372 1373 1374 1375 378 379 1380 1381 1386
VP R6 Z VP R6 Z VP R6 Z VP R6 Z VP R6 Z VP R6 Z VP R6 Z VP R6 Z VP R6 Z
8/80 8/100 8/120 10/80 10/100 10/115 10/135 10/160 10/200
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
do mm
hef mm
df mm
Ch mm
8x80 8x100 8x120 10x80 10x100 10x115 10x135 10x160 10x200
5,5x85 5,5x105 5,5x125 7x80 7x105 7x120 7x140 7x165 7x205
90 110 130 90 110 125 145 170 210
10 30 50 10 30 45 65 90 130
8 8 8 10 10 10 10 10 10
70 70 70 70 70 70 70 70 70
8 8 8 10 10 10 10 10 10
10 10 10 13 13 13 13 13 13
Screw length calculation: Lv > Lt + Tfix
Examples of applications
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values VP R6 Substrate materials Pull out values in daN Concrete C20/25 Solid brick Double brick UNI with plaster
VP R6 Ø8
VP R6 Ø10
380 300 120
480 380 150
1 daN≃1 kg
317
universal and frame fixings
Lt = Plug length h1 = Min. hole depth do = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Hole diameter in the fixture dnom = Plug diameter hef = Effective anchorage depth Ch = Spanner
universal and frame fixings
Vorpa VP R6 ET Multi-purpose nylon fixing with European Technical Assesment for concrete
concrete
solid clay brick
solid brick
products group Approved for • non-cracked concrete C12/15 - C50/60 VP R6 ET • building materials use with chipboard screw category A-B-C-D ETAG 020 and Torx recess
universal and frame fixings
Also suitable for • solid brick • hollow brick • perforated brick • aerated poroton
To fix • light carpentry • wood coatings • handrails • wood substructures • door frames • window frames • counter frames
ETAG 020 for use categories A-B-C-D
product information Characteristics • nylon plug for frames and light carpentry • European Technical Assesment ETAG 020 • guarantees a simple installation • wide range of applications • suitable for push-through installation • plug with special anti-rotation wings • the higher lenght allows the anchor to contain the entire thickness of the element to be fastened
Installation • through setting anchor Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation
Examples of applications
318
hollow brick autoclaved aerated concrete
universal and frame fixings
Vorpa VP R6 ET Multi-purpose nylon fixing with European Technical Assesment for concrete
concrete
solid clay brick
installation sequence
solid brick
hollow brick autoclaved aerated concrete
On solid brick
Make a drill hole with a hammer drill
Place the fixture and then Put the anchor by hammering Make sure that the fixture insert the anchor into the hole softly on the screw head until is supported by the anchor the fixture stops the nylon (nylon plug and screw) plug
Clean the hole
Place the fixture and the anchor into the hole by hand
On hollow brick
Make a drill hole just by rotary drilling
Clean the hole before the installation
Put the anchor by hammering softly on the screw head until the fixture stops the nylon plug
Sent the screw by screw driver or by hand. Make sure that the fixture is supported by the anchor (nylon plug and screw)
product code and technical data
VP R6 ET with chipboard screw and Torx recess Code
Description
1139 1140 1141
VP R6 ET 10/230 TX40 VP R6 ET 10/260 TX40 VP R6 ET 10/300 TX40
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
do mm
hef mm
df mm
10x230 10x260 10x300
7x235 7x265 7x305
80 80 80
160 190 230
10 10 10
70 70 70
11 11 11
Lt = Plug length h1 = Min. hole depth do = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Hole diameter in the fixture dnom = Plug diameter hef = Effective anchorage depth
Examples of applications
319
universal and frame fixings
Clean the hole
universal and frame fixings
Vorpa VP R6 ET Multi-purpose nylon fixing with European Technical Assesment for concrete
concrete
solid clay brick
solid brick
technical data
universal and frame fixings
Installation parameters USE CATEGORY A Concrete ≥C16/20 Concrete ≥C12/15
mm mm
hmin
Ccrn
Cmin
Smin
100 100
100 140
60 80
60 80
Single anchor Cmin
hollow brick autoclaved aerated concrete
Anchor group * Smin
Smin(1)
Smin(2)
100
100
100
200
180
100
100
100
200
100
100
100
100
200
Installation parameters USE CATEGORY B-C-D Solid clay brick
mm
120
Hollow brick
mm
Autoclaved aerated concrete
mm
hmin
* The design method valid for single anchor and groups with two or four anchors. (1) In direction perpendicular to free edge (2) In direction parallel to free edge Characteristic tension resistance USE CATEGORY A Concrete ≥C16/20 Concrete ≥C12/15 Design tension loads USE CATEGORY A Concrete ≥C16/20 Concrete ≥C12/15
Ø10 4,0 3,0
kN kN
Ø10 2,2 1,6
kN kN
Characteristic resistance USE CATEGORY B Clay brick Clay brick Clay brick Clay brick Calcium silicate brick
Density (kg/dm3) ≥1,70 ≥1,70 ≥2,0 ≥2,0 ≥2,0
Compressive strength (N/mm2) ≥10 ≥20 ≥10 ≥20 ≥20
Frk (1) (kN) 2,5 3,5 2,5 3,5 3,5
Characteristic resistanceUSE CATEGORY C USE CATEGORY C Porotherm 25P+W MAX 250 Perforated ceramic brick Calcium silicate hollow block Hollow lightweight aggregate concrete
Density (kg/dm3) ≥0,8 ≥0,8 ≥1,2 ≥1,6 ≥0,8
Compressive strength (N/mm2) ≥15 ≥15 ≥12 ≥12 ≥2
Frk (1) (kN) 0,9 0,9 2,0 2,5 1,5
Characteristic resistance USE CATEGORY D Autoclaved aerated concrete AAC2 Autoclaved aerated concrete AAC7
Density (kg/dm3) ≥0,35 ≥0,65
Compressive strength (N/mm2) ≥2 ≥6,5
Frk (1) (kN) 0,6 1,5
(1) Characteristic resistance Frk for tension, shear or combined tension and shear loading. The characteristic reistance is valid for single anchor or for group of two or four plastic anchors with a spacing equal or larger than the minimum spacing (Smin) according to installation parameters.
320
universal and frame fixings
Vorpa VPA Multi-purpose nylon fixing for frame and light carpentry
concrete
natural stone
solid brick
products group Suitable for • concrete • natural stone VPA with chipboard screw • solid brick
*
To fix • light carpentry • wood coatings • handrails • wood substructures • door frames • window frames • counter frames
VPA INOX A2 with A2 SS chipboard screw and Torx recess
A2 INOX 304
*
product information Installation • through setting anchor Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation
Clean the hole before the installation
installation sequence
Make a drill hole with a hammer drill
Clean the hole
Place the fixture and then Put the anchor by hammering Make sure that the fixture is insert the anchor into the hole softly on the screw head until supported by the anchor the fixture stops the nylon (nylon plug and screw) plug
Examples of applications
321
universal and frame fixings
Characteristics • nylon plug for frames and light carpentry • the expanding portion has a limited length, the use is suggested mainly with solid materials • guarantees a simple installation • wide range of applications • suitable for push-through installation • plug with special anti-rotation wings • the higher lenght allows the anchor to contain the entire thickness of the element to be fastened
universal and frame fixings
Vorpa VPA Multi-purpose nylon fixing for frame and light carpentry
concrete
natural stone
solid brick
product code and technical data
VPA with chipboard screw
universal and frame fixings
Code
304 348 *3230 305 349 323 306 307 308 309 310
Description
VPA 6/60 VPA 8/60 VPA TX 8/60 VPA 8/80 VPA 8/100 VPA 8/120 VPA 10/80 VPA 10/100 VPA 10/115 VPA 10/135 VPA 10/160
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
do mm
hef mm
df mm
6x60 8x60 8x60 8x80 8x100 8x120 10x80 10x100 10x115 10x135 10x160
4x65 5,5x65 5,5x65 5,5x85 5,5x105 5,5x125 7x85 7x105 7x120 7x140 7x165
70 70 70 90 110 130 95 115 130 150 175
30 20 20 40 60 80 30 50 65 85 110
6 8 8 8 8 8 10 10 10 10 10
30 40 40 40 40 40 50 50 50 50 50
7 9 9 9 9 9 11 11 11 11 11
* With chipboard screw Torx recess T30
Lt = Plug length h1 = Min. hole depth do = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Hole diameter in the fixture dnom = Plug diameter hef = Effective anchorage depth Ch = Spanner Screw length calculation: Lv > Lt + Tfix
VPA A2 with A2 SS chipboard screw and Torx recess Code
Description
4140 4141 4142 4143 4144 4145 4146 4147 4148
VP A A2 VP A A2 VP A A2 VP A A2 VP A A2 VP A A2 VP A A2 VP A A2 VP A A2
8/60 TX30 8/80 TX30 8/100 TX30 8/120 TX30 10/80 TX40 10/100 TX40 10/115 TX40 10/135 TX40 10/160 TX40
A2 INOX 304
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
do mm
hef mm
df mm
8x60 8x80 8x100 8x120 10x80 10x100 10x115 10x135 10x160
5,5x65 5,5x85 5,5x105 5,5x125 7x85 7x105 7x120 7x140 7x165
70 90 110 130 95 115 130 150 175
20 40 60 80 30 50 65 85 110
8 8 8 8 10 10 10 10 10
40 40 40 40 50 50 50 50 50
9 9 9 9 11 11 11 11 11
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values VPA Substrate materials Pull out values in daN Concrete C20/25 Solid brick
VPA Ø6
VPA Ø8
VPA Ø10
200 150
340 300
420 350
322
1 daN≃1 kg
universal and frame fixings
Vorpa FSS-FSC Through steel screw for windows frame
concrete
natural stone
solid brick
products group FSS with flat-head
FSC with cylinder-head
To fix • door frames • window frames
Suitable for • concrete • natural stone • solid brick
product information Installation • through setting anchor Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation
Clean the hole before the installation
installation sequence On solid brick
Examples of applications
323
On hollow brick
universal and frame fixings
Characteristics • special threaded steel screws Torx recess for window frames • quick, easy, economical • efficient work • no additional plugs are required for screw installation • the continuous thread prevents the window frame from being pulled against the substrate • stress-free and long-lasting fixing of frame • the special thread reduces the amount of force required for screwing in the screws • cylinder-head screws are recommended for recessed installation in wooden profiles • flat-head screws are recommended for installation in plastic and alluminium profiles
universal and frame fixings
Vorpa FSS-FSC Through steel screw for windows frame
concrete
natural stone
product code and technical data
universal and frame fixings
FSS with flat-head T30 Code
Description
2410 2408 2428 2411 2412 2413 2414 2415 2416 2417 2430 2418 2419 2420 2427 2429
FSS 7,5x42 FSS 7,5x52 FSS 7,5x62 FSS 7,5x72 FSS 7,5x82 FSS 7,5x92 FSS 7,5x102 FSS 7,5x112 FSS 7,5x122 FSS 7,5x132 FSS 7,5x142 FSS 7,5x152 FSS 7,5x182 FSS 7,5x212 FSS 7,5x252 FSS 7,5x302
do mm
h1 mm
Øv x Lv mm
Øt mm
Ch mm
6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6
55 65 75 85 95 105 115 125 135 145 155 165 195 225 265 315
7,5x42 7,5x52 7,5x62 7,5x72 7,5x82 7,5x92 7,5x102 7,5x112 7,5x122 7,5x132 7,5x142 7,5x152 7,5x182 7,5x212 7,5x252 7,5x302
10,8-11,8 10,8-11,8 10,8-11,8 10,8-11,8 10,8-11,8 10,8-11,8 10,8-11,8 10,8-11,8 10,8-11,8 10,8-11,8 10,8-11,8 10,8-11,8 10,8-11,8 10,8-11,8 10,8-11,8 10,8-11,8
T30 T30 T30 T30 T30 T30 T30 T30 T30 T30 T30 T30 T30 T30 T30 T30
Examples of applications
324
h1 Lv Øv do Øt ch
= Min. hole depth = Screw length = Screw diameter = Hole diameter = Head screw diameter = Spanner
solid brick
universal and frame fixings
Vorpa FSS-FSC Through steel screw for windows frame
concrete
natural stone
solid brick
product code and technical data FSC with cylinder-head T15 Code
T25 Code
T30 Code
2432 2457 2433 2471 2434 2435 2472
2468 2469 2470
32460 32458 32459 32461 32462 32463 32464 32465 32466 32467 32473 32468 32469 32470 32474 32471 32475 32472 32476
FSC 5x52 FSC 5x62 FSC 5x72 FSC 5x82 FSC 5x92 FSC 5x102 FSC 5x112 FSC 7,5x42 FSC 7,5x52 FSC 7,5x62 FSC 7,5x72 FSC 7,5x82 FSC 7,5x92 FSC 7,5x102 FSC 7,5x112 FSC 7,5x122 FSC 7,5x132 FSC 7,5x142 FSC 7,5x152 FSC 7,5x182 FSC 7,5x212 FSC 7,5x242 FSC 7,5x252 FSC 7,5x272 FSC 7,5x302 FSC 7,5x322
do mm
h1 mm
Øv x Lv mm
4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6
62 72 82 92 102 112 122 55 65 75 85 95 105 115 125 135 145 155 165 195 225 255 265 285 315 335
5x52 5x62 5x72 5x82 5x92 5x102 5x112 7,5x42 7,5x52 7,5x62 7,5x72 7,5x82 7,5x92 7,5x102 7,5x112 7,5x122 7,5x132 7,5x142 7,5x152 7,5x182 7,5x212 7,5x242 7,5x252 7,5x272 7,5x302 7,5x322
Øt T25 mm
Øt T30 mm
7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70
8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5
7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70
h1 = Min. hole depth Lv = Screw length Øv = Screw diameter do = Hole diameter Øt = Head screw diameter ch = Spanner T15 = Torx Recess 15 T25 = Torx Recess 25 T30 = Torx Recess 30
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values FSS - FSC screws Ø7,50mm ≥ 30 mm
≥ 40 mm
Pull out values in daN FSS - FSC screws Ø 7,50 mm 320 Concrete C20/25 Solid brick EN 771-2 Italian standard hollow brick with plaster (doppio UNI EN 771-1) Aerated concrete -
320 -
325
Concrete Solid brick 1 daN ≃1 kg Embedment depth hef ≥ 30 mm hef ≥ 40 mm 160 80
≥ 60 mm
Hollow brick doppio UNI Lightweight concrete hef ≥ 60 mm
he ≥ 60 mm
universal and frame fixings
2460 2458 2459 2461 2462 2463 2464 2465 2466 2467
Description
universal and frame fixings
Vorpa VGN Nylon frame fixing
concrete
solid brick
perforated brick
aerated poroton
perforated cement
products group To fix • door frames • window frames • facades
Suitable for • concrete • solid brick VGN • perforated brIck with chipboard screw • aerated poroton • perforated cement
product information
universal and frame fixings
Characteristics • nylon frame anchor with metal screw for window and door frames • ensures a stress-free and long-lasting fixing of frame • the special plug geometry anchors the metal and plastic profiles against compressive and tensile loads • allows for a secure hold of the window frame • suitable for push-through installation
Installation • through setting anchor Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation
Clean the hole before the installation
installation sequence
product code and technical data Code
266 273 268 274 275 276 277 278 279
Description
VGN 8/75 VGN 8/100 VGN 8/120 VGN 8/140 VGN 10/75 VGN 10/100 VGN 10/120 VGN 10/140 VGN 10/165
dnom x Lt mm
h1 mm
hef mm
Tfix mm
do mm
df mm
8x75 8x100 8x120 8x140 10x75 10x100 10x120 10x140 10x165
55 55 55 55 55 55 55 55 55
50 50 50 50 50 50 50 50 50
30 50 70 90 30 50 70 90 115
8 8 8 8 10 10 10 10 10
8 8 8 8 10 10 10 10 10
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values
Lt = Plug length h1 = Min. hole depth do = Hole diameter Tfix = Fixture thickness df = Hole diameter in the fixture dnom = Plug diameter hef = Effective anchorage depth
VGN Substrate materials Pull out values in daN Concrete C20/25 Solid brick Italian standard hollow brick with plaster (doppio UNI)
VGN Ø8
VGN Ø10
300 280 80
520 480 120
326
1 daN≃1 kg
universal and frame fixings
Vorpa VGA Steel frame fixing
concrete
solid brick
aerated poroton
products group
VGA TSC with pan-head screw
To fix • door frames • window frames • facades
Suitable for • concrete • solid brick • aerated poroton
VGA TSP with flat-head screw
product information Characteristics • metal frame anchor with metric screw for window and door frames • ensures a stress-free and long-lasting fixing of frame • the special plug geometry anchors the metal and plastic profiles against compressive and tensile loads • suitable for push-through installation
Installation • through setting anchor
Clean the hole before the installation
installation sequence
product code and technical data Code
Description
2267 2270 2266 2273 2268 2274 2269 2275 2276 2277 2278 2279 2280
VGA 8/92 TSC * VGA 8/112 TSC * VGA 8/72 TSP VGA 8/92 TSP VGA 8/112 TSP VGA 8/132 TSP VGA 8/152 TSP VGA 10/72 TSP VGA 10/92 TSP VGA 10/112 TSP VGA 10/132 TSP VGA 10/152 TSP VGA 10/182 TSP
dnom x Lt mm
h1 mm
hef mm
Tfix mm
do mm
df mm
8x92 8x112 8x72 8x92 8x112 8x132 8x152 10x72 10x92 10x112 10x132 10x152 10x182
90 90 90 90 90 90 90 90 90 90 90 90 90
60 60 60 60 60 60 60 60 60 60 60 60 60
25 45 5 25 45 65 85 5 25 45 65 85 115
8 8 8 8 8 8 8 10 10 10 10 10 10
8 8 8 8 8 8 8 10 10 10 10 10 10
Lt = Anchor length h1 = Min. hole depth do = Hole diameter Tfix = Fixture thickness df = Hole diameter in the fixture dnom = Plug diameter hef = Effective anchorage depth
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values VGA Substrate materials Pull out values in daN Concrete C20/25 Solid brick
VGA Ø8
VGA Ø10
280 -
530 500
327
1 daN≃1 kg
universal and frame fixings
Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation
universal and frame fixings
Vorpa CLAPS Nylon fixing for frames and subframes products group To fix • door frames • window frames • doors and windows • subframes
CLAPS
product information
universal and frame fixings
Characteristics • fixing in plastic material for fixing frames and subframes
installation sequence
Place the subframe
Insert the fixing of plastic material at the point of the window in which the fixing will be carried out
Once the fixation has been completed, remove the unused claps
product code and technical data Code
Description
1870 1871 1872
CLAPS 2 CLAPS 3 CLAPS 5
Thickness mm
Colour
2 3 5
neutro grigio nero Ls L S P D A B
Examples of applications
328
= = = = = = =
40 32 8 4 ,5 36 18 9
mm mm mm mm mm mm mm
universal and frame fixings
Vorpa VH BU Nylon plug
perforated brick
hollow brick
products group VH BU with 8.8 hexagonal head screw
To fix • furniture • shelves • profiles
Suitable for • perforated brick • hollow brick
product information Characteristics • nylon plug with diagonal slots • anti-rotation system during the installation • smooth expansion thanks to the slots on the body shear nut
Installation • to be mounted aligned the wall Suggestion for use • check load bearing capacity values • respect the installation data • clean the hole before the installation universal and frame fixings
installation sequence
Clean the hole before the installation
product code and technical data
Code
Description
52310 VH 8 BU 52312 VH 10 BU
Lt mm
Screw d x Lv mm
do mm
h1 mm
tfix max mm
Ch
45 65
M8x80 M10x90
12 14
80 80
10 15
13 17
h1 Lt Lv do d tfix Ch
= Min. hole depth = Anchor length = Screw length = Hole diameter = Screw diameter = Fixture thickness = Spanner
VH BU Substrate materials Recommended loads in daN Hollow brick
VH BU 8
VH BU 10
20
30
1 daN≃1 kg
329
universal and frame fixings
Vorpa Thermoiso Plus Anchorage system for masonry coated by heat-insulating panels - ETICS
concrete
natural stone
lightweight concrete
aerated concrete
solid brick
hollow brick
perforated brick
products group To fix • blinds • hinges • rain descendants • shelters • curtains
Suitable for • concrete • natural stone • lightweight concrete • aerated concrete • solid brick • hollow brick • perforated brick Thermoiso Plus
universal and frame fixings
product information Fixing system consisting of: 1. 2mm thick wrought iron sheet structure and punched M12 and M16 threaded rod, welded to provide extra load resistance. Zinc coating electrolytic for corrosion protection.
• innovative anchorage system for masonry coated by heat-insulating panels and insulation materials. • high mechanical strength even on panels lined with panels high thickness insulators. • elimination of the so-called “thermal bridge” internal-external, ie prevents thermal dispersions in edifices, condensates and molds. • Thermoiso Plus is universal, it can be used on any type of masonry, both full and perforated. • quick, practical and intuitive application does not require any particulars equipment, only one drill-machine, a drill bit and a chemical cartridge • drilling diameter reduced compared to conventional methodologies. • the thermoiso system is convenient because it offers a solution to • ideal fixation at a low cost. it is advisable to use an adhesive sealant on the back of the support ring to prevent any water infiltration in the panel.
2. The system allows applications on insulated walls with a thickness of 60 mm to 160 mm (205 mm on compact walls). It is also possible to use it on larger coats reducing the shear load; polyamide sleeve specially designed to accommodate M8, M10 or M12 accessories and Ø 6 to Ø12 wood screws. Avoids the contact of the threaded with the bearing structure in metal,eliminating the thermal bridge between the interior and exterior of the building. 3. The support ring gives a pleasant aesthetic finish and allows perfect alignment to the wall; special perforated sleeve for anchoring with injection resins on perforated walls (on compact masonry is not required
Hinges and general frames
Roofs and canopies
Rainwater pipes
Wall parabolic dishes
External air conditioners
Wall heaters
330
universal and frame fixings
Vorpa Thermoiso Plus Anchorage system for masonry coated by heat-insulating panels - ETICS
concrete
natural stone
lightweight concrete
aerated concrete
solid brick
hollow brick
perforated brick
installation sequence Application sequence of Thermoiso Plus on hollow materials with perforated sleeve
Application sequence of Thermoiso Plus on solid materials
product code and technical data Test report for thermal transmittance
A
Code
C
Description
A) Total length mm
B) Max insulation panel thickness mm
C) Thread length mm
Ø Hole on hollow brick mm
Ø Hole on solid brick mm
58742 58744 58743 58745
Thermoiso Plus Ø6 - Ø16x215 - 140 Thermoiso Plus Ø6 - Ø16x260 - 185 Thermoiso Plus Ø8 - Ø16x215 - 140 Thermoiso Plus Ø8 - Ø16x260 - 185
215 260 215 260
140 185 140 185
80 125 80 125
16 16 16 16
16 16 16 16
58740 58746 58741 58747
Thermoiso Plus M10 - Ø20x240 - 145 Thermoiso Plus M10 - Ø20x285 - 190 Thermoiso Plus M12 - Ø20x240 - 145 Thermoiso Plus M12 - Ø20x285 - 190
240 285 240 285
145 (160)* 190 (205)* 145 (160)* 190 (205)*
90 135 90 135
20 20 20 20
20 20 20 20
* On solid brick, the threaded bar can be inserted into the supporting masonry with a minimum depth of 75 mm. so you can consider a max thickness of insulation panel of 160 mm and 205 mm. Code 58742/58744 for wood screws Ø6
Code 58743/58745 for wood screws Ø8 - M8
Code 58740/58746 for metric screws M10 and wood screws Ø10
Code 58741/58747 for metric screws M12 and wood screws Ø12
Accessories Hinges
Firm shutters
Threaded screw
Threaded bar
Wood screws
Double thread screw
M10 - M12
Ø6 - Ø7 - Ø8
M8 - M10 - M12
M8 - M10 - M12
Ø7 - Ø8 - Ø10 - Ø12
Ø6 - Ø8 - Ø10 - Ø12
331
universal and frame fixings
B
universal and frame fixings
Vorpa Thermoiso Plus Anchorage system for masonry coated by heat-insulating panels - ETICS
concrete
natural stone
lightweight concrete
aerated concrete
solid brick
hollow brick
accessories Perforated sleeves CVX N
Code
58732 58731
universal and frame fixings
23001
Adhesive sealant
Description
Content ml
Perforated sleeve CVX N Ø16x85 Thermoiso Plus 6 e 8 Perforated sleeve CVX N Ø20x100 Thermoiso Plus M10 e M8 Adhesive sealant MS-POLYMER SiMP•SEAL 55
290
Chemical anchor PSF rticale Sta in ve ropic Thixot
ETAG 001-05 for non cracked concrete M8-M16 threaded bar
Code
1124 1002P 1005
Description
PSF 300 PSF 400 Mixer
ETAG 029 for masonry and hollow walls - Cat.c,w/d M10 Steel elements according to Table 2 Annex 5 ETA-11/0511
Test report nr. 276986 14/12/2010 on wood substrates
Content ml
Mixer n°
300 410
1 1
Store upright
Manual caulking gun
Code
Description
1009
Metal caulking gun 300 ml professional 2,5 kN Metal caulking gun 410 ml professional 2,5 kN
1101
Dust cleaning manual pump
Suitable for
Cleaning brush
Code Description
PSF 300
1072 Dust cleaning manual pump
PSF 400
1049 Cleaning brush holes Ø 10 - Ø 20 brush length mm 100 1059 Cleaning brush holes Ø 20 - Ø 30 brush length mm 100
332
length mm. 225
perforated brick
universal and frame fixings
Vorpa Thermoiso Plus Anchorage system for masonry coated by heat-insulating panels - ETICS
concrete
natural stone
lightweight concrete
aerated concrete
solid brick
hollow brick
perforated brick
technical data
Thermoiso Plus - anchorage system for masonry coated by heat-insulating panels Loads on concrete and solid material Shear 2) Tfix 50 mm
Tfix 60 mm
Tfix 70 mm
Tfix 80 mm
Tfix 90 mm
Tfix 100 mm
Tfix 110 mm
Tfix 120 mm
Tfix 130 mm
Tfix 140 mm
Tfix 150 mm
Tamm
Vamm
Vamm
Vamm
Vamm
Vamm
Vamm
Vamm
Vamm
Vamm
Vamm
Vamm
Smin
Cmin
daN
daN
daN
daN
daN
daN
daN
daN
daN
daN
daN
daN
mm
mm
60
56
53
50
48
46
44
42
28
25
20
80
80
90
80
70
60
40
50
45
40
35
30
25
80
80
165
155
145
135
125
117
110
105
95
80
65
100
100
Minimum Edge axial distance spacing
20 50 80 90 90 90
1daN ≈ 1Kg
Tfix ≈ insulation panel thickness
Load perforated brick (Poroton) Shear 2)
Thermoiso Plus 6-Ø16 - Wood screws Ø6x50 Thermoiso Plus 6-Ø16 - Wood screws Ø6x60 Thermoiso Plus 6-Ø16 - Wood screws Ø7x85 Thermoiso Plus 8-Ø16 - Hex.head screw Ø8x70 Thermoiso Plus M10-Ø20 - Metric hex.screw M10x803) Thermoiso Plus M20-Ø20 - Metric hex.screw M12x803) 1daN ≈ 1Kg
Pull out 1)
Tfix 50 mm
Tfix 60 mm
Tfix 70 mm
Tfix 80 mm
Tfix 90 mm
Tfix 100 mm
Tfix 110 mm
Tfix 120 mm
Tfix 130 mm
Tfix 140 mm
Tfix 150 mm
Tamm
Vamm
Vamm
Vamm
Vamm
Vamm
Vamm
Vamm
Vamm
Vamm
Vamm
Vamm
Smin
Cmin
daN
daN
daN
daN
daN
daN
daN
daN
daN
daN
daN
daN
mm
mm
60
56
53
50
48
46
44
42
28
25
20
80
80
90
80
70
60
40
50
45
40
35
30
25
80
80
120
112
105
97
90
85
80
75
70
62
45
100
100
Minimum Edge axial distance spacing
20 50 65 75 60 60 Tfix ≈ insulation panel thickness
Test report available
1) Tensile loads include an appropriate safety coefficient 2) Cut-off loads are considered as a function of a maximum displacement of 3mm. For more information on higher displacement, contact Vorpa Technical Support.
3) Data refer to tests performed with UNi metric screws 5739 class 8.8 with insertion depth inside the 60 mm thermal insulation sleeve.
333
universal and frame fixings
Thermoiso Plus 6-Ø16 - Wood screws Ø6x50 Thermoiso Plus 6-Ø16 - Wood screws Ø6x60 Thermoiso Plus 6-Ø16 - Wood screws Ø7x85 Thermoiso Plus 8-Ø16 - Hex.head screw Ø8x80 Thermoiso Plus M10-Ø20 - Metric hex.screw M10x803) Thermoiso Plus M12-Ø20 - Metric hex.screw M12x803)
Pull out 1)
universal and frame fixings
Vorpa Thermoiso Plus Anchorage system for masonry coated by heat-insulating panels - ETICS
concrete
natural stone
lightweight concrete
aerated concrete
solid brick
technical data
EXTRACT FROM TEST REPORT N. 337967 OF 25/11/2016
universal and frame fixings
Calculation of thermal transmittance for thermal insulation coat (Ethics) bymeans of the Finite Element Method, in accordance with UN in EN 6946: 2008 and UN and EN isO 10211: 2008
334
hollow brick
perforated brick
universal and frame fixings
Vorpa VSL Wood building screw
wood
products group Suitable for • wood
VSL ribs under head no pre-countersinking
extra-deep torx bit
high quality surface treatment for fast and easy application
milling thread reducing risk of splitting
cutting edge
fast screw pitch successfully reduced labor time by 40%
To fix • outside fittings • covering • big structures • wood carpentry
EAD 130118-00-0603 for wood applications
product information Installation • through setting anchor Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • clean the hole before the installation
installation sequence
Examples of applications
335
universal and frame fixings
Characteristics • wood building screw , TORX recess • drilling is not necessary • suitable for permanent and removable fixings both inside and outside • high performances in wood • no risk to make slits on the wood thanks to the milling body • special pre-drilling design • quick pitch thread
universal and frame fixings
Vorpa VSL Wood building screw
wood
product code and technical data VSL
universal and frame fixings
Code
93264 93265 93266 93267 93268 93269 93270 93271 93272 93273 93274 93275 93276 93277 93278 93279 93280 93281 93282 93283 93284 93285 93286 93287 93288 93289 93290 93291 93292 93293 93294 93295 93296 93297 93298 93299 93300 93301 93302 93303 93304 93305 93306 93307 93308 93309 93310
Description
VSL 4 VSL 4 VSL 4 VSL 4 VSL 4 VSL 4 VSL 4 VSL 4,5 VSL 4,5 VSL 4,5 VSL 4,5 VSL 4,5 VSL 5 VSL 5 VSL 5 VSL 5 VSL 5 VSL 5 VSL 5 VSL 6 VSL 6 VSL 6 VSL 6 VSL 6 VSL 6 VSL 6 VSL 6 VSL 6 VSL 6 VSL 6 VSL 6 VSL 6 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
30 40 45 50 60 70 80 40 50 60 70 80 40 50 60 70 80 100 120 60 80 100 120 140 160 180 200 220 240 260 280 300 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360
1 kN≃100 kg
Lv mm
dv mm
h1 mm
Tfix max mm
Characteristic resistance kN
*Recommended load kN
Ch mm
30 40 45 50 60 70 80 40 50 60 70 80 40 50 60 70 80 100 120 60 80 100 120 140 160 180 200 220 240 260 280 300 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360
4 4 4 4 4 4 4 4,5 4,5 4,5 4,5 4,5 5 5 5 5 5 5 5 6 6 6 6 6 6 6 6 6 6 6 6 6 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8
20 24 27 30 36 42 48 24 30 36 42 48 24 30 36 42 48 60 70 36 48 60 70 70 70 70 70 70 70 70 70 70 50 60 70 80 80 80 80 80 80 80 80 80 80 80 80
10 16 18 20 24 28 32 16 20 24 28 32 16 20 24 28 32 40 50 24 32 40 50 70 90 110 130 150 170 190 210 230 30 40 50 60 80 100 120 140 160 180 200 220 240 260 280
0,78 0,94 1,06 1,18 1,41 1,65 1,88 1,06 1,32 1,59 1,85 2,12 1,18 1,47 1,76 2,06 2,35 2,94 3,43 2,12 2,82 3,53 4,12 4,12 4,12 4,12 4,12 4,12 4,12 4,12 4,12 4,12 3,92 4,70 5,49 6,27 6,27 6,27 6,27 6,27 6,27 6,27 6,27 6,27 6,27 6,27 6,27
0,19 0,23 0,26 0,29 0,35 0,41 0,47 0,26 0,33 0,39 0,46 0,53 0,29 0,36 0,44 0,51 0,58 0,73 0,85 0,53 0,70 0,88 1,03 1,03 1,03 1,03 1,03 1,03 1,03 1,03 1,03 1,03 0,98 1,17 1,37 1,56 1,56 1,56 1,56 1,56 1,56 1,56 1,56 1,56 1,56 1,56 1,56
T20 T20 T20 T20 T20 T20 T20 T25 T25 T25 T25 T25 T25 T25 T25 T25 T25 T25 T25 T30 T30 T30 T30 T30 T30 T30 T30 T30 T30 T30 T30 T30 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40
ATTENTION: An appropriate safety factor ≥ 4 should be applied on these values * The table shows the permissible loads for tension, shear and combined tension and shear loads 336
Lv dv Tfix Ch
= Screw length = Screw diameter = Fixture thickness = Spanner (impronta Torx)
Follows on the next page
universal and frame fixings
Vorpa VSL Wood building screw
wood
product code and technical data VSL
Code
VSL 8 VSL 8 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10
x x x x x x x x x x x x x x x x x x x
380 400 90 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400
Lv mm
dv mm
h1 mm
380 400 90 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400
8 8 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10
80 80 60 60 70 80 80 80 80 80 80 80 80 80 80 80 80 80 80
Tfix max mm
300 320 30 40 50 60 80 100 120 140 160 180 200 220 240 260 280 300 320
Characteristic resistance kN
*Recommended load kN
Ch mm
6,27 6,27 4,96 5,91 6,86 7,84 7,84 7,84 7,84 7,84 7,84 7,84 7,84 7,84 7,84 7,84 7,84 7,84 7,84
1,56 1,56 1,24 1,47 1,71 1,96 1,96 1,96 1,96 1,96 1,96 1,96 1,96 1,96 1,96 1,96 1,96 1,96 1,96
T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40
ATTENTION: An appropriate safety factor ≥ 4 should be applied on these values * The table shows the permissible loads for tension, shear and combined tension and shear loads
Examples of applications
337
Lv dv Tfix Ch
= Screw length = Screw diameter = Fixture thickness = Spanner (impronta Torx)
universal and frame fixings
93311 93312 93461 93460 93313 93314 93315 93316 93317 93318 93319 93320 93321 93322 93323 93324 93325 93326 93327
Description
1 kN≃100 kg
universal and frame fixings
Vorpa CLICK-UP Safety witholding hook for tiles products group Suitable for • facade with adhesive
To fix • ceramic slabs • tiles
CLICK-UP
universal and frame fixings
Tested by
PATENTED
A2 INOX 304
BREVETTATO product information Characteristics • The glued façade is a system that makes it possible to get goodlooking results and less recurring maintenance than other equivalent systems. This type of covering uses adhesive to attach ceramic slabs directly onto the plaster of the building exterior. However, to ensure the laying of slabs over 30cm it is necessary to adopt an additional safety devise against detachment of the adhesive due to tensions arising from structural adjustments, stretching and extension to thermal excursions, earthquake shakings, etc. • The concealed Vorpa Click-Up system is a patented device that ensures the connection of the ceramic slab to the wall by an invisible mechanical hook inserted in the slab itself through an engrave before laying. After having covered the slab with glue and installed it, the hook is subsequently secured to the wall by a plug.
• The Vorpa Click-Up system provides pull-out load over 350kg* for each application point stated by specific laboratory tests. This allows great safety in case of detachment of the glue between wall and slab together with fast and practical installation. (*Click-Up M-type on 11mm porcelain tiles with adhesive). • Vorpa Click-Up safety hooks are made of 0,5mm AISI304 stainless steel in four different sizes according to thickness of slabs (minimum 6mm). They are supplied ready for assembly to back side slabs once made the incision by Click-Cut grooving toll.
Examples of application
338
universal and frame fixings
Vorpa CLICK-UP Safety witholding hook for tiles installation sequence 1
Engraving slab by grooving tol Click-Cut
4
3
Insert the hook in the engrave
Laying the glue on the slab and wall
5
Fix the hook with plug and screw
universal and frame fixings
Install the slab to the wall with glue
2
Work completed
Examples of application
Slab back side
Slab front side
Insulating panels on solid masonry
Insulating panels on hollow masonry
339
universal and frame fixings
Vorpa CLICK-UP Safety witholding hook for tiles product code and technical data Art. 4086
Art. 4087
CLICK-UP S (small) (slabs thickness from 6mm to 10mm)
CLICK-UP M (medium)
30
30 CLICK-UP
CLICK-UP
CLICK-UP
9
9
9
9
9
8,5
8,5
9
8,5
8,5
universal and frame fixings
13
r1 5,6
97
8,5 8,5
8,5
35°
9 8,5
8,5
8,5
35°
13
8,5
8,5 8,5
8,5
Pieces per tile
≤ 60 cm ≤ 150 cm ≤ 240 cm ≤ 320 cm
8,5
99
8,5
5
10 60 150 240
9 8,5
100
101
8,5
Tile length
30 0,5
CLICK-UP
8,5
r1
(slabs thickness from 15mm to 30mm and more)
30 0,5
0,5
35°
Art. 4089 CLICK-UP XL (extra-large)
(slabs thickness from 9mm to 15mm) (slabs thickness from 12mm to 20mm)
0,5
Tested by
Art. 4088 CLICK-UP L (large)
35°
13
8,5
13
r1
r1
9
7,2
1 daN=1kg daN
Pieces per box
Click-Up recommended load (B)
(A)
S (small)
M (medium)
L (large)
XL (extra large)
1 2 3 4
45 daN
55 daN
60 daN
65 daN
500
(A) The number of hooks is indicative. However, it is recommended being the designer to identify the number of hooks for tile/slab according to dimensions, base material, local regulations and environment conditions. A2 INOX 304 (B) Recommended loads are stated applying a safety factor equal to 4.
Sectional view
Examples of application plug facade
ceramic slab
engraves
Click-Up
glue
340
universal and frame fixings
Vorpa CLICK-UP Safety witholding hook for tiles accessories Threaded bar for application on masonry coated with insulating panels M6x16
Code
91038 91075 91042
Description
Internal thread
Max thickness of insulating panel mm
Min. embedment depth on masonry mm
Ø hole on hollow masonry mm
Ø hole on solid masonry mm
M6x14 M6x14 M6x14
80 100 120
80 80 80
16 16 16
14 14 14
Threaded bar Ø12x160 Threaded bar Ø12x180 Threaded bar Ø12x200
Other sizes on request
Chemical anchor PSF universal and frame fixings
rticale Sta in ve ropic Thixot
ETAG 001-05 for non cracked concrete M8-M16 threaded bar
Code
1124 1002P 1005
Test report nr. 276986 14/12/2010 on wood substrates
ETAG 029 for masonry and hollow walls - Cat.c,w/d M10 Steel elements according to Table 2 Annex 5 ETA-11/0511
Description
PSF 300 PSF 400 Mixer
Content ml
Mixer n°
300 410
1 1
Store upright
Perforated plastic sleeve CVX N to be used on hollow masonry
Code
58732
Description
Perforated sleeve CVX N Ø16x85
Click-cut grooving tool
Ø hole on hollow masonry mm
Code
Description
Ø16
4099
Grooving tool Click-Cut
A - Wing nut to adjust the slab thickness and block.
B
D
A
B - Wing nut to adjust the cutting inclination, the right inclination of Click-Cut flute Device for engraving slabs is 55° for each size Click-Up hook. C - Flange to adjust the cutting position. D - Wing nut to adjust the cutting depth.
C 341
5
Fixings for insulation
fixings for insulation
Vorpa VPL Insulation panels fixings
polystyrene
extruded polystyrene
products group
VPL Ø25
To fix • plumbing and light flues • external wall lighting • shop-signs and traffic-signs • postboxes
Suitable for • polystyrene panels • extruded polystyrene • heat insulating and soundproofing panels
VPL TE Ø34
Ideal for applications on compact masonry covered by heat insulating panels and rigid insulation materials whose minimum thickness is 50 mm.
fixings for insulation
product information Characteristics • nylon light fixing to be used on masonry covered by rigid insulating panels • made of chemical agents resistant and paintable nylon • easy and quick installation by T40 bit or hexagonal head screw M8 • no need to pre-drill • ideal also for applications on ETICS systems • ideal to fix rigid insulation materials whose minimum thickness is 50mm • possibility to remove the object to maintenance without compromise the anchoring resistance • the fixing material prevents the thermal bridge phenomenon, avoiding heat waste
Installation • to be mounted aligned with the insulation panels by screwing and without pre-drilling Suggestion for use • in order to prevent the seepage of water in the insulation material, the plug’s edge must be sealed with acrylic sealant or silicone after the installation has been completed • when VPL fixing is mounted aligned with the insulation panels, the object to be fixed must be anchored by: - VPL: frame screw Ø4,5 or Ø5,5 mm - VPL TE: metrical screw M8 and Ø8 and Ø10 mm
installation sequence
Point the fixing on the masonry
Screw by using a drill without pre-drilling
Screw the frame screw inside VPL fixing
Installation completed
Examples of applications VPL TE
Examples of applications
344
fixings for insulation
Vorpa VPL Insulation panels fixings
polystyrene
extruded polystyrene
product code and technical data
VPL Ø25
h1
Code
Description
Lt mm
Screw length
For screw Ø mm
IS-penetration of screw min-max mm
S mm
4520 4521 4523 4517 4518 4519
VPL 50 VPL 60 VPL 85 VPL 120 VPL 150 VPL 180
50 60 85 120 150 180
IS + Tfix IS + Tfix IS + Tfix IS + Tfix IS + Tfix IS + Tfix
4,5 - 5,5 4,5 - 5,5 4,5 - 5,5 4,5 - 5,5 4,5 - 5,5 4,5 - 5,5
25-45 30-50 55-70 70-100 100-130 100-160
≥ 50 ≥ 60 ≥ 85 ≥ 120 ≥ 150 ≥ 180
TX40 T4X0 TX40 TX40 T4X0 TX40
Ø
tfix
Tinst d0
d Ch Lt
Lt = Anchor length Tfix = Fixture thickness S = Insulation material thickness dv = Screw diameter Lv = Screw length
M Lv Code
Description
dv xLv mm
Thread
To be used on
92224 92273
Vite M6x40 Vite M8x40
4,5x40 5,5x40*
M6 M8
VPL VPL TE
* to be used with minimum density 35 kg/m3
fixings for insulation
VPL 95 Ø34
Code
Description
Lt mm
4522
VP L 95 TE
95
Screw length mm
For screw Ø mm
IS-penetration of screw min-max mm
S mm
Bit
50-80
≥ 100
hex head spanner 13
IS + Tfix Hex head screw M8 wood screw Ø8-Ø10
One hex head bolt M8x30 is included in each box
Accessories VPL TE
Hexagonal bolt screw
Hexagonal bolt wood screw
Double thread screw
ATTENTION: An appropriate safety factor ≥ 4 should be applied on VPL Tension VPL 50 VPL 60 VPL 85 VPL TE 95 VPL 120 VPL 150 VPL 180 Recommended loads daN 1 daN≃1 kg Plystyrene PS 15 - PS 20 4,0 5,0 7,0 10,0 12,0 14,0 16,0
345
fixings for insulation
Vorpa PVC SPACER PVC spacer for fastening on insulated walls
mineral wool
mineral wool lamella
polystyrene extruded panels polystyrene
products group
SPACER PVC
Suitable for • thermal panels • acoustic panels • glass wool panel
To fix • brackets • profiles • fixings on coated walls • threaded bars
product information Characteristics • various lenghts available 1 meter, 10 mm, 30 mm, 50 mm, 100 mm • PVC spacer for fastenings • rigid and soft panels, to be used as support fixing for traditional systems • fixing with threaded bars, chemical anchors on coated walls
Installation • to be mounted aligned with the insulation panels • pierce wall and insulation panel • pierce the insulation panel Ø35 or Ø45 as the desired PVC spacer
fixings for insulation
product code and technical data Code
Description
L mm
External diameter
Internal hole diameter
Threaded bar Ø mm
1163 1164
PVC spacer Ø35x1000 PVC spacer Ø45x1000
1000 1000
35 45
13 20
10-12 14-16-20
1225 1226 1227 1228
PVC spacer Ø35x10 PVC spacer Ø35x30 PVC spacer Ø35x50 PVC spacer Ø35x100
10 30 50 100
35 35 35 35
13 13 13 13
10-12 10-12 10-12 10-12
1229 1230 1231 1232
PVC spacer Ø45x10 PVC spacer Ø45x30 PVC spacer Ø45x50 PVC spacer Ø45x100
10 30 50 100
45 45 45 45
20 20 20 20
14-16-20 14-16-20 14-16-20 14-16-20
Examples of applications
346
fixings for insulation
Vorpa ISO CE 8 NYLON Nylon fixing for insulation panels with European Technical Assesment
polystyrene extruded panels polystyrene
PANELS
products group
concrete
lightweight concrete
BASE MATERIALS
Approved for • concrete • lightweight concrete • lightweight aggregate blocks • solid clay bricks • solid brick • hollow brick
lightweight aggregate block
solid clay brick
solid brick
hollow brick
To fix • polystyrene panels • extruded polystyrene • heat insulating and soundproofing panels
ISO CE 8 NYLON
Ideal for applications on masonry coated by solid heat insulating panels and insulation materials.
CALCULATION SOFTWARE
ETA 014 for use categories A-B-C-D-E
product information Characteristics • polyamide fixing with fiberglass reinforced polyamide pin for all types of solid insulation materials. Use categories A-B-C-D-E. • reduced thermal transfer • easy and quick installation, the expansion is carried out by hammering the pin inside the nylon fixing • reduced embedment depth enables reduced drilling times • special washer Ø140mm permits the fixing on lightweight insulation materials • special fiberglass reinforced polyamide pin
Installation • to be mounted aligned with the insulation panels Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • when calculating the usable length it is suggested to take into consideration eventual extra thicknesses such as glues, sealants, old plasters fixings for insulation
installation sequence
Wait till the sealant between the insulation panel and the base material is completely dry
Drill the base material with an appropriate drill bit
Insert the nylon fixing without pin until the washer rests again the insulation
Examples of applications
347
Fix the pin by hammering gently until full expansion, i.e. when the head is leveled with washer surface
fixings for insulation
Vorpa ISO CE 8 NYLON Nylon fixing for insulation panels with European Technical Assesment
PANELS
product code and technical data Code
Description
5775 5776 5777 5778 5779 5780
ISO CE 8 NY 8/95 ISO CE 8 NY 8/115 ISO CE 8 NY 8/135 ISO CE 8 NY 8/155 ISO CE 8 NY 8/175 ISO CE 8 NY 8/195
polystyrene extruded panels polystyrene
Lt mm
95 115 135 155 175 195
do mm
8 8 8 8 8 8
h1 mm
hef mm
≥351)/≥752) ≥351)/≥752) ≥351)/≥752) ≥351)/≥752) ≥351)/≥752) ≥351)/≥752)
≥251)/≥652) ≥251)/≥652) ≥251)/≥652) ≥251)/≥652) ≥251)/≥652) ≥251)/≥652)
concrete
lightweight concrete
lightweight aggregate block
BASE MATERIALS
Tfix mm
Lt-hef-Ttol Lt-hef-Ttol Lt-hef-Ttol Lt-hef-Ttol Lt-hef-Ttol Lt-hef-Ttol
T T T T T T
P mm
+T +T +T +T +T +T
+h +h +h +h +h +h
fix
tol
ef
fix
tol
ef
fix
tol
ef
fix
tol
ef
fix
tol
ef
fix
tol
ef
solid clay brick
ØT mm
60 60 60 60 60 60
solid brick
dp mm
Lnp mm
4,8 4,8 4,8 4,8 4,8 4,8
1) = Use categories A,B,C,D 2) = Use category E
100 120 140 160 180 200
hollow brick
b mm
44 44 44 44 44 44
hmin = 100 mm Cmin = 100 mm Smin = 100 mm
fixings for insulation
Lt = Anchor length h1 = Min. hole depth do = Hole diameter hef = Embedment depth Tfix = Fixture thickness P = Total depth of holes dp = Pin diameter Lnp = Pin length b = Pin’s knurling length Ttol = Thickness of equalizing and/ or non-load-bearing layer hmin = Min. base material thickness Smin = Min. anchor spacing Cmin = Min. edge distance
Accessories Code
55762
DISCO 140
Description
ØT mm
ISO DISCO CE 140
140
Characteristic loading values according to ETA ATTENTION: An appropriate safety factor ≥ 2 should be applied on these values ISO CE 8 NYLON Substrate materials
Class
Density Kg/dm3
daN
Pull out values in daN 1 daN≃1 kg ≥ 2.25 50 C12/15 concrete A ≥ 2.30 75 C16/20 - C50/60 concrete A ≥ 2.00 75 Clay bricks / calcium silicate bricks B ≥ 1.60 75 Calcium Silicate hollow blocks C ≥ 1.20 60 Vertically perforated clay bricks C ≥ 0.80 40 Porotherm 25 C ≥ 0.88 60 Lightweight aggregate concrete blocks LAC D ≥ 0.35 75 Autoclaved aerated concrete elements AAC2 E ≥ 0.65 90 Autoclaved aerated concrete elements AAC7 E ETAG 014 light fixings Use Category A B C D E
Building materials Normal weight concrete Solid masonry - Silicate blocks Hollow or perforated masonry Lightweight aerated concrete Autoclave aerated concrete
348
fixings for insulation
Vorpa ISO CE 8 Nylon fixing for insulation panels with European Technical Assesment products group
mineral wool
mineral wool lamella
polystyrene extruded panels polystyrene
PANELS
ISO CE 8
concrete
lightweight concrete
BASE MATERIALS
Approved for • concrete • lightweight concrete • lightweight aggregate blocks • solid clay bricks • solid brick • hollow brick
lightweight aggregate block
solid clay brick
solid brick
hollow brick
To fix • polystyrene panels • extruded polystyrene • mineral wool lamella/mineral wool
Ideal for applications on masonry coated by solid and soft heat insulating panels and insulation materials.
CALCULATION SOFTWARE
ETA 014 for use categories A-B-C-D-E
product information Installation • to be mounted aligned with the insulation panels Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • when calculating the usable length it is suggested to take into consideration eventual extra thicknesses such as glues, sealants, old plasters fixings for insulation
Characteristics • polyamide fixing with white galvanized steel pin, head coated with plastic suitable for all types of insulation materials. Use categories A-B-C-D-E • reduced thermal transfer due to plastic endings of metal pin • easy and quick installation, the expansion is carried out by hammering the pin inside the nylon fixing • reduced embedment depth enables reduced drilling times • special washer Ø140mm permits the fixing on lightweight insulation materials • pin’s head covered by fiberglass reinforced polyamide • the steel pin is suitable for all types of insulation materials and particularly for rigid insulation materials
installation sequence
Wait till the sealant between the insulation panel and the base material is completely dry
Drill the base material with an appropriate drill bit
Insert the nylon fixing without pin until the washer rests again the insulation
Examples of applications
349
Fix the pin by hammering gently until full expansion, i.e. when the head is leveled with washer surface
fixings for insulation
Vorpa ISO CE 8 Nylon fixing for insulation panels with European Technical Assesment product code and technical data
mineral wool
mineral wool lamella
polystyrene extruded panels polystyrene
PANELS
concrete
lightweight concrete
BASE MATERIALS
lightweight aggregate block
solid clay brick
hollow brick
Code
Description
Lt mm
do mm
h1 mm
hef mm
Tfix mm
P mm
ØT mm
dp mm
Lnp mm
5747 5748 5749 5750 5751 5752
ISO CE 8 8/95 ISO CE 8 8/115 ISO CE 8 8/135 ISO CE 8 8/155 ISO CE 8 8/175 ISO CE 8 8/195
95 115 135 155 175 195
8 8 8 8 8 8
≥351)/≥752) ≥351)/≥752) ≥351)/≥752) ≥351)/≥752) ≥351)/≥752) ≥351)/≥752)
≥251)/≥652) ≥251)/≥652) ≥251)/≥652) ≥251)/≥652) ≥251)/≥652) ≥251)/≥652)
Lt - hef - Ttol Lt - hef - Ttol Lt - hef - Ttol Lt - hef - Ttol Lt - hef - Ttol Lt - hef - Ttol
Tfix+Ttol+hef Tfix+Ttol+hef Tfix+Ttol+hef Tfix+Ttol+hef Tfix+Ttol+hef Tfix+Ttol+hef
60 60 60 60 60 60
4,8 4,8 4,8 4,8 4,8 4,8
100 120 140 160 180 200
1) = Use categories A,B,C,D 2) = Use category E
hmin = 100 mm Cmin = 100 mm Smin = 100 mm
Lt = Anchor length h1 = Min. hole depth do = Hole diameter hef = Embedment depth Tfix = Fixture thickness P = Total depth of holes dp = Pin diameter Lnp = Pin length b = Pin’s knurling length Ttol = Thickness of equalizing and/ or non-load-bearing layer hmin = Min. base material thickness Smin = Min. anchor spacing Cmin = Min. edge distance
fixings for insulation
solid brick
Accessories Code
55762
DISCO 140 Description
ØT mm
ISO DISCO CE 140
140
Characteristic loading values according to ETA ATTENTION: An appropriate safety factor ≥ 2 should be applied on these values ISO CE 8 Substrate materials
Class
Density Kg/dm3
daN
Pull out values in daN 1 daN≃1 kg ≥ 2.25 50 C12/15 concrete A ≥ 2.30 75 C16/20 - C50/60 concrete A ≥ 2.00 75 Clay bricks / calcium silicate bricks B ≥ 1.60 75 Calcium Silicate hollow blocks C ≥ 1.20 60 Vertically perforated clay bricks C ≥ 0.80 40 Porotherm 25 C ≥ 0.88 60 Lightweight aggregate concrete blocks LAC D ≥ 0.35 75 Autoclaved aerated concrete elements AAC2 E ≥ 0.65 90 Autoclaved aerated concrete elements AAC7 E ETAG 014 light fixings Use Category A B C D E
Building materials Normal weight concrete Solid masonry - Silicate blocks Hollow or perforated masonry Lightweight aerated concrete Autoclave aerated concrete
350
fixings for insulation
Vorpa ISO CE 10 MC Nylon fixing for insulation panels with European Technical Assesment products group
polystyrene extruded panels polystyrene
PANELS
concrete
lightweight concrete
BASE MATERIALS
Approved for • concrete • lightweight concrete • lightweight aggregate blocks • solid clay bricks • solid brick
lightweight aggregate block
solid clay brick
solid brick
To fix • polystyrene panels • extruded polystyrene • heat insulating and soundproofing panels
ISO CE 10 MC
Ideal for applications on compact masonry coated by heat insulating panels and rigid insulation materials
CALCULATION SOFTWARE
ETA 014 for use categories A-B-C-D-E
product information Characteristics • polyamide fixing with pin made of fiberglass reinforced polyamide suitable for the fixing of rigid insulation panels on compact materials. Use categories A-B-C-D-E • reduced thermal transfer • easy and quick installation, the expansion is carried out by hammering the pin inside the nylon fixing • reduced embedment depth enables reduced drilling times • pin made of fiberglass reinforced polyamide
Installation • to be mounted aligned with the insulation panels Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • when calculating the usable length it is suggested to take into consideration eventual extra thicknesses such as glues, sealants, old plasters fixings for insulation
installation sequence
Wait till the sealant between the insulation panel and the base material is completely dry
Drill the base material with an appropriate drill bit
Insert the nylon fixing without pin until the washer rests again the insulation
Examples of applications
351
Fix the pin by hammering gently until full expansion, i.e. when the head is leveled with washer surface
fixings for insulation
Vorpa ISO CE 10 MC Nylon fixing for insulation panels with European Technical Assesment product code and technical data
polystyrene extruded panels polystyrene
PANELS
concrete
lightweight concrete
BASE MATERIALS
lightweight aggregate block
solid brick
Code
Description
Lt mm
do mm
h1 mm
hef mm
Tfix mm
P mm
ØT mm
dp mm
Lnp mm
b mm
5765 5766 5767 5768 5769 5770 5771 5772 5773 5774
ISO CE MC 10 10/70 ISO CE MC 10 10/90 ISO CE MC 10 10/110 ISO CE MC 10 10/120 ISO CE MC 10 10/140 ISO CE MC 10 10/160 ISO CE MC 10 10/180 ISO CE MC 10 10/200 ISO CE MC 10 10/220 ISO CE MC 10 10/260
70 90 110 120 140 160 180 200 220 260
10 10 10 10 10 10 10 10 10 10
≥401/≥602 ≥401/≥602 ≥401/≥602 ≥401/≥602 ≥401/≥602 ≥401/≥602 ≥401/≥602 ≥401/≥602 ≥401/≥602 ≥401/≥602
≥301/≥502 ≥301/≥502 ≥301/≥502 ≥301/≥502 ≥301/≥502 ≥301/≥502 ≥301/≥502 ≥301/≥502 ≥301/≥502 ≥301/≥502
Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef
Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1
60 60 60 60 60 60 60 60 60 60
5,5 5,5 5,5 5,5 5,5 5,5 5,5 5,5 5,5 5,5
75 95 115 125 145 165 185 205 225 265
44 44 44 44 44 44 44 44 44 44
1) = Use categories A,B,C,D 2) = Use category E
fixings for insulation
solid clay brick
Lt = Anchor length h1 = Min. hole depth do = Hole diameter hef = Embedment depth Tfix = Fixture thickness P = Total depth of holes dp = Pin diameter Lnp = Pin length b = Pin’s knurling length Ttol = Thickness of equalizing and/ or non-load-bearing layer hmin = Min. base material thickness Smin = Min. anchor spacing Cmin = Min. edge distance
hmin = 100 mm Cmin = 100 mm Smin = 100 mm
np
dp b
Characteristic loading values according to ETA ATTENTION: An appropriate safety factor ≥ 2 should be applied on these values ISO CE 10 MC Substrate materials
Class
Density Kg/dm3
daN
Pull out values in daN 1 daN≃1 kg C12/15 concrete A ≥ 2.25 50 C20/25 - C50/60 concrete A ≥ 2.30 75 Clay bricks B ≥ 2.00 75 Calcium silicate solid brick B ≥ 2.00 60 Calcium silicate hollow blocks C ≥ 1.60 60 Vertically perforate clay bricks C ≥ 1.20 60 Porotherm 25 C ≥ 0.80 40 Lightweight aggregate concrete solid blocks D ≥ 0.88 60 Autoclaved aerated concrete blocks AAC2 E ≥ 0.35 50 Autoclaved aerated concrete blocks AAC7 E ≥ 0.65 60 ETAG 014 light fixings Use category A B C D E
Building materials Normal weight concrete Solid masonry - Silicate blocks Hollow or perforated masonry Lightweight aerated concrete Autoclave aerated concrete
352
fixings for insulation
Vorpa ISO CE 10 MF Nylon fixing for insulation panels with European Technical Assesment
polystyrene extruded panels polystyrene
PANELS
products group
silica brick class 15
lightweight aggregate block
solid clay brick
solid brick
hollow brick
BASE MATERIALS
Approved for • silica brick class 15 • lightweight aggregate block • solid clay brick • solid brick • hollow brick
To fix • polystyrene panels • extruded polystyrene • heat insulating and soundproofing panels
ISO CE 10 MF
Ideal for applications on compact masonry coated by heat insulating panels and rigid insulation materials
CALCULATION SOFTWARE
ETA 014 for use categories B-C-E
product information Characteristics • polyamide fixing with pin made of fiberglass reinforced polyamide suitable for the fixing of rigid insulation panels on perforated and compact materials. Use categories B-C-E • reduced thermal transfer • easy and quick installation, the expansion is carried out by hammering the pin inside the nylon fixing • reduced embedment depth enables reduced drilling times • pin made of fiberglass reinforced polyamide • particularly indicated to fix rigid insulation materials
Installation • to be mounted aligned with the insulation panels Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • when calculating the usable length it is suggested to take into consideration eventual extra thicknesses such as glues, sealants, old plasters fixings for insulation
installation sequence
Wait till the sealant between the insulation panel and the base material is completely dry
Drill the base material with an appropriate drill bit
Insert the nylon fixing without pin until the washer rests again the insulation
Examples of applications
353
Fix the pin by hammering gently until full expansion, i.e. when the head is leveled with washer surface
fixings for insulation
Vorpa ISO CE 10 MF Nylon fixing for insulation panels with European Technical Assesment
polystyrene extruded panels polystyrene
PANELS
product code and technical data
Code
Description
Lt mm
do mm
h1 mm
hef mm
5755 5756 5757 5758 5759 5760 5761
ISO CE MF 10 10/140 ISO CE MF 10 10/160 ISO CE MF 10 10/180 ISO CE MF 10 10/200 ISO CE MF 10 10/220 ISO CE MF 10 10/260 ISO CE MF 10 10/300
140 160 180 200 220 260 300
10 10 10 10 10 10 10
90 90 90 90 90 90 90
80 80 80 80 80 80 80
Tfix mm
Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef
silica brick hollow brick class 15
BASE MATERIALS
lightweight aggregate block
solid brick
P mm
ØT mm
dp mm
Lnp mm
b mm
S mm
Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1
60 60 60 60 60 60 60
5,3 5,3 5,3 5,3 5,3 5,3 5,3
140 160 180 200 220 260 300
85 85 85 85 85 85 85
10 10 10 10 10 10 10
1) = Use categories A,B,C,D 2) = Use category E Lt = Anchor length h1 = Min. hole depth do = Hole diameter hef = Embedment depth Tfix = Fixture thickness P = Total depth of holes dp = Pin diameter Lnp = Pin length b = Pin’s knurling length Ttol = Thickness of equalizing and/ or non-load-bearing layer hmin = Min. base material thickness Smin = Min. anchor spacing Cmin = Min. edge distance
fixings for insulation
solid clay brick
hmin = 100 mm Cmin = 100 mm Smin = 100 mm
Characteristic loading values according to ETA ATTENTION: An appropriate safety factor ≥ 2 should be applied on these values ISO CE 10 MF Substrate materials
Class
Density Kg/dm3
daN
Pull out values in daN 1 daN≃1 kg ≥ 2.00 75 Solid clay brick B ≥ 1.20 80 Perforated brick C ≥ 1.60 50 Calcium silicated solid bricks C ≥ 0.80 50 Porotherm 25 C ≥ 0.35 30 Autoclaved aerated concrete AAC2 E ≥ 0.65 85 Autoclaved aerated concrete AAC7 E
ETAG 014 light fixings Use category A B C D E
Building materials Normal weight concrete Solid masonry - Silicate blocks Hollow or perforated masonry Lightweight aerated concrete Autoclave aerated concrete
354
fixings for insulation
Vorpa ISO TL Nylon fixing for insulation panels with European Technical Assesment
mineral wool
mineral wool lamella
polystyrene extruded panels polystyrene
PANELS
products group
ISO TL Lt ≤ 130 mm
ISO TL Lt ≥ 150 mm
Suitable for • concrete • solid clay brick • solid brick • hollow brick
concrete
solid clay brick
solid brick
hollow brick
BASE MATERIALS
To fix • polystyrene panels • extruded polystyrene • mineral wool lamella/mineral wool
Ideal for applications on masonry coated by heat insulating panels, soft and rigid insulation materials
CALCULATION SOFTWARE
ETA 014 for use categories A-B-C
product information Installation • to be mounted aligned with the insulation panels Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • when calculating the usable length it is suggested to take into consideration eventual extra thicknesses such as glues, sealants, old plasters
installation sequence
Wait till the sealant between the insulation panel and the base material is completely dry
Drill the base material with an appropriate drill bit
Insert the nylon fixing without pin until the washer rests again the insulation
Examples of applications
355
Fix the pin by hammering gently until full expansion, i.e. when the head is leveled with washer surface
fixings for insulation
Characteristics • polyethylene fixing with fiberglass reinforced nylon PA6 pin suitable to fix rigid and soft insulation materials on hollow and compact materials. Use categories A-B-C • reduced thermal transfer granting energy saving • easy and quick installation, the expansion is carried out by hammering the pin inside the nylon fixing • special fiberglass reinforced polyamide pin granting more resistance to the fixing
fixings for insulation
Vorpa ISO TL Nylon fixing for insulation panels with European Technical Assesment
mineral wool
mineral wool lamella
polystyrene extruded panels polystyrene
PANELS
product code and technical data
concrete
solid clay brick
solid brick
hollow brick
BASE MATERIALS
Code
Description
Lt mm
do mm
h1 mm
hef mm
Tfix mm
P mm
ØT mm
dp mm
Lnp mm
Sp mm
5744 655 656 657 658 * 740 748 752 5745 5746
ISO TL ISO TL ISO TL ISO TL ISO TL ISO TL ISO TL ISO TL ISO TL ISO TL
60 70 90 110 120 130 150 180 210 240
10 10 10 10 10 10 10 10 10 10
40 40 40 40 40 40 40 40 40 40
30 30 30 30 30 30 30 30 30 30
30+Ttol 40+Ttol 60+Ttol 80+Ttol 90+Ttol 100+Ttol 120+Ttol 150+Ttol 180+Ttol 210+Ttol
Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1
53 53 53 53 53 53 58 58 58 58
5,3 5,3 5,3 5,3 5,3 5,3 5,6 5,6 5,6 5,6
68 68 68 88 108 128 148 178 210 238
2,6 2,6 2,6 2,6 2,6 2,6 2,6 2,6 2,6 2,6
10/60 10/70 10/90 10/110 10/120 10/130 10/150 10/180 10/210 10/240
*Non included in ETA
fixings for insulation
Lt = Anchor length h1 = Min. hole depth do = Hole diameter hef = Embedment depth Tfix = Fixture thickness P = Total depth of holes dp = Pin diameter Lnp = Pin length Sp = Head thickness Ttol = Thickness of equalizing and/ or non-load-bearing layer
Characteristic loading values according to ETA ATTENTION: An appropriate safety factor ≥ 2 should be applied on these values ISO TL Substrate materials Class Density Kg/dm3 daN Pull out values in daN 1 daN≃1 kg C20/25 concrete C50/60 concrete Solid brick/ Solid clay brick Hollow brick
≥ 2.30 ≥ 2.40 ≥ 2.00 ≥ 0.95
A A B C
39 42 47 22
ETAG 014 light fixings Use category A B C D E
Building materials Normal weight concrete Solid masonry - Silicate blocks Hollow or perforated masonry Lightweight aerated concrete Autoclave aerated concrete
356
fixings for insulation
Vorpa ISO Nylon fixing for insulation panels
polystyrene extruded panels polystyrene
PANELS
products group Suitable for • concrete • natural stone • solid brick
ISO
concrete
natural stone
solid brick
BASE MATERIALS
To fix • polystyrene panels • extruded polystyrene • heat insulating and soundproofing panels
Ideal for applications on masonry coated by heat insulating panels and rigid insulation materials
product information Characteristics • polypropylene fixing without pin suitable to fix rigid insulation materials on compact materials. • reduced thermal transfer • easy and quick installation • different lengths available grants the possibility to be used with different panels thickness • the anchoring is carried out by the thread compression inside the hole on compact material
Installation • to be mounted aligned with the insulation panels Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data • when calculating the usable length it is suggested to take into consideration eventual extra thicknesses such as glues, sealants, old plasters
installation sequence
Drill the base material with an appropriate drill bit
Insert the nylon fixing without pin until the washer rests again the insulation
product code and technical data Code
Description
Lt mm
do mm
h1 mm
hef mm
Tfix mm
P mm
ØT mm
Sp mm
650 651 660 652 733 734 5736
ISO 8/50 ISO 8/70 ISO 8/80 ISO 8/90 ISO 8/110 ISO 8/130 ISO 8/160
50 70 80 90 110 130 160
8 8 8 8 8 8 8
40 40 40 40 40 40 40
30 30 30 30 30 30 30
20-Ttol 40-Ttol 50-Ttol 60-Ttol 80-Ttol 100-Ttol 130-Ttol
Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1
35 35 35 35 35 35 35
2,6 2,6 2,6 2,6 2,6 2,6 2,6
ATTENTION: An appropriate safety factor ≥ 2 should be applied on these values
Lt = Anchor length h1 = Min. hole depth do = Hole diameter hef = Embedment depth Tfix = Fixture thickness P = Total depth of holes dp = Pin diameter Lnp = Pin length Sp = Head thickness Ttol = Thickness of equalizing and/ or non-load-bearing layer
ISO Substrate materials daN Pull out values in daN 1 daN≃1 kg Concrete C20/25 Solid brick Perforated clay blocks and partitions Italian standard hallow brick with plaster
40 20 15 15
357
fixings for insulation
Wait till the sealant between the insulation panel and the base material is completely dry
fixings for insulation
Vorpa ISO DISK Ø58 Nylon fixing for insulation panels
mineral wool
mineral wool lamella
polystyrene extruded panels polystyrene
products group
ISO DISK Ø58
Suitable for • polystyrene panels • extruded polystyrene • heat insulating and soundproofing panels • mineral wool lamella/mineral wool
product information Characteristics • HD polypropylene disc, for fixing insulating panels on wood or masonry. The disk is fixed to the support with a Ø6mm selftapping screw with countersunk head or a Ø8mm hammer-in plug. Particularly suitable for fixing mineral wool or cellular glass insulating panels. The closing cap provides complete insulation of the thermal bridge and allows a perfect leveling of the wall
Characteristics • flexible for any type of support • with closing cap for better shaving and thermal insulation • can be combined with hammer-in nylon plug with reduced head Ø8mm • can be combined with a countersunk head wood screw for wooden supports, plywood, wood chipboard
installation sequence
fixings for insulation
On hollow brick
On wood substrate
The tightening of the self-tapping or percussion screw, inserted in the central seat of the disco, creates the right pressure for fixing the insulation
product code and technical data Code
55764
Description
ISO DISK PEHO 6
df mm
ØT mm
Sp mm
8
58
2,5
df = Internal hole diameter ØT = Head diameter Sp = Head thickness
Examples of applications
With hammer-in nylon plug Ø8*mm • concrete • solid brick • hollow brick
With self-tapping screw • wood substrates • boards • panels
* Vorpa VP Ø8mm
358
Vorpa Srl Via San Leo 5, 47838 Riccione - RN - Italy Tel. +39 0541 607111 Fax +39 0541 691847 www.vorpa.com - vorpa@vorpa.com
6
Cladding andpipe fixings
cladding and pipe fixings
Vorpa IF - IFO Steel pipe clamp
concrete
natural stone
solid brick
products group Suitable for • concrete • natural stone • solid brick
IF pipe clamp with rubber and plastic plug
To fix • industrial plants • high temperature exhaust fumes • high temperature liquid discharge
IFO pipe clamp with rubber
Isophonic pipe clamp with EPDM rubber for iron and polyethylene pipes According to DIN 4109 sound protection
product information Characteristics • isophonic pipe clamps with EPDM rubber and wall plastic plug • two screws allows for easy adjustment to suit the outer pipe diameter • combination nut with thread M8/M10 • the sound insulation rubber offers noise protection and avoids contact corrosion • screws safety feature • wall nylon plug VN with anti-rotation wings
• temperature range -40°C ÷ +100°C • fire resistance DIN 4109-B2 Suggestion for use • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
cladding and pipe fixings
installation sequence
Clean the hole before the installation
Examples of applications
362
cladding and pipe fixings
Vorpa IF - IFO Steel pipe clamp
concrete
natural stone
solid brick
product code and technical data IFO pipe clamp with rubber Code Description
2699 2700 2701 2702 2703 2704 2705 2706 2707 2708 2709 2710 2711 2712 2713 2714 2715 2716 2718S 2718 2719
IFO pipe clamp IFO pipe clamp IFO pipe clamp IFO pipe clamp IFO pipe clamp IFO pipe clamp IFO pipe clamp IFO pipe clamp IFO pipe clamp IFO pipe clamp IFO pipe clamp IFO pipe clamp IFO pipe clamp IFO pipe clamp IFO pipe clamp IFO pipe clamp IFO pipe clamp IFO pipe clamp IFO pipe clamp IFO pipe clamp IFO pipe clamp
12-15 15-19 20-25 26-30 32-36 38-43 47-51 53-58 60-64 68-72 76-80 81-86 87-92 99-105 107-112 113-118 125-130 135-140 159-166 168-172 200-212
Nominal diameter
ExD
A-B mm
M thread
Side screws
1/4 3/8 1/2 3/4 1” 1” 1/4 1” 1/2 53-58 2” 68-72 2” 1/2 81-86 3” 3” 1/2 107-112 4” 125-130 5” 159-166 6” 200-212
19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 20x2,3 20x2,3 20x2,3 20x2,3 20x2,3 20x2,3 20x2,3
9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16
M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10
M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20
IF pipe clamp with rubber and plastic plug Code Description
IF pipe clamp/plug IF pipe clamp/plug IF pipe clamp/plug IF pipe clamp/plug IF pipe clamp/plug IF pipe clamp/plug IF pipe clamp/plug IF pipe clamp/plug IF pipe clamp/plug IF pipe clamp/plug IF pipe clamp/plug IF pipe clamp/plug IF pipe clamp/plug IF pipe clamp/plug IF pipe clamp/plug IF pipe clamp/plug IF pipe clamp/plug IF pipe clamp/plug IF pipe clamp/plug IF pipe clamp/plug IF pipe clamp/plug
12-15 15-19 20-25 26-30 32-36 38-43 47-51 53-58 60-64 68-72 76-80 81-86 87-92 99-105 107-112 113-118 125-130 135-140 159-166 168-172 200-212
ExD
doxLt mm
h1 mm
M x Lp mm
Side screws
1/4 3/8 1/2 3/4 1” 1” 1/4 1” 1/2 53-58 2” 68-72 2” 1/2 81-86 3” 3” 1/2 107-112 4” 125-130 5” 159-166 6” 200-212
19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 20x2,3 20x2,3 20x2,3 20x2,3 20x2,3 20x2,3 20x2,3
10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60
80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80
M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90
M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20
do = Hole diameter h1 = Min. hole depth Lt = Anchor length Lp = Pin length ExD = Width x thickness M = Thread
IF - IFO Pipe size daN Axial recommended load 1 daN≃1 kg 1/4” - 3” 1/2 107 - 212
180 250
363
cladding and pipe fixings
4699 4700 4701 4702 4703 4704 4705 4706 4707 4708 4709 4710 4711 4712 4713 4714 4715 4716 4717S 4717 4718
Nominal diameter
cladding and pipe fixings
Vorpa BRM - BRG Steel pipe clamp
concrete
natural stone
solid brick
products group To fix • industrial plants • plumbing and heating systems • run water vapor systems
Suitable for • concrete • natural stone • solid brick
BRM steel clamp with nylon plug and double threaded screw
Steel pipe clamp for steel pipes
BRG steel clamp
product information BRG steel pipe clamp Code
Description
4472 4474 4476 4477 4478 4479 4480 4481 4482 4483 4484 4485 4486 4487 4488
BRG steel clamp BRG steel clamp BRG steel clamp BRG steel clamp BRG steel clamp BRG steel clamp BRG steel clamp BRG steel clamp BRG steel clamp BRG steel clamp BRG steel clamp BRG steel clamp BRG steel clamp BRG steel clamp BRG steel clamp
16-20 20-24 25-30 32-36 38-44 46-50 58-62 74-80 82-89 112-118 74-80 82-89 112-118 130-141 164-172
Nominal diameter
ExD
M thread
Side screws
3/8 1/2 3/4 1” 1” 1/4 1” 1/2 2” 2” 1/2 3” 4” 2” 1/2 3” 4” 5” 6”
20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5
M8 M8 M8 M8 M8 M8 M8 M8 M8 M8 M10 M10 M10 M10 M10
M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25
cladding and pipe fixings
BRM steel clamp with nylon plug and double threaded screw Code
Description
1210 1211 1212 1213 1214 1215 1216 1217 1218 1219 1220 1221 1222 1223 1224
BRM steel clamp/plug 16-20 BRM steel clamp/plug 20-24 BRM steel clamp/plug 25-30 BRM steel clamp/plug 32-36 BRM steel clamp/plug 38-44 BRM steel clamp/plug 46-50 BRM steel clamp/plug 58-62 BRM steel clamp/plug 74-80 BRM steel clamp/plug 82-89 BRM steel clamp/plug 112-118 BRM steel clamp/plug 74-80 BRM steel clamp/plug 82-89 BRM steel clamp/plug 112-118 BRM steel clamp/plug 130-141 BRM steel clamp/plug 164-172
Nominal diameter
ExD mm
do x Lt mm
h1 mm
M x Lp mm
Side screws
3/8 1/2 3/4 1” 1” 1/4 1” 1/2 2” 2” 1/2 3” 4” 2” 1/2 3” 4” 5” 6”
20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5
10 x 60 10 x 60 10 x 60 10 x 60 10 x 60 10 x 60 10 x 60 10 x 60 10 x 60 10 x 60 12 x 60 12 x 60 12 x 60 12 x 60 12 x 60
80 80 80 80 80 80 80 80 80 80 80 80 80 80 80
M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M10x120 M10x120 M10x120 M10x120 M10x120
M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25
do = Hole diameter h1 = Min. hole depth Lt = Anchor length Lp = Pin length ExD = Width x thickness M = Thread
• always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation BRM - BRG Pipe size daN Axial recommended load 1 daN≃1 kg 3/8” - 6”
250
364
cladding and pipe fixings
Vorpa VRM - VR inox A2 Steel pipe clamp
concrete
natural stone
solid brick
products group Suitable for • concrete • natural stone • solid brick
VRM INOX A2 A2 Stainless steel clamp with wall plastic plug and double threaded screw
A2 INOX 304
VR INOX A2 A2 Stainless steel clamp
To fix • industrial plants • plumbing and heating systems • run water vapor systems • coastal areas • food industries • plants on farms • sewage plants • shipyards plants
A2 stainless steel clamps for iron pipes, flues, air ducts Ideal corrosion protection
installation sequence
Clean the hole before the installation
Examples of applications
cladding and pipe fixings
365
cladding and pipe fixings
Vorpa VRM - VR inox A2 Steel pipe clamp
concrete
natural stone
solid brick
product code and technical data A2 INOX
VR INOX A2 Stainless steel clamp Code
Description
3410 3411 3412 3413 3414 3415 3416 3417 3418 3421 3419 3420 3422 3423 3427 3424 3428 3425 3426 3429 3430
VR INOX A2 steel clamp VR INOX A2 steel clamp VR INOX A2 steel clamp VR INOX A2 steel clamp VR INOX A2 steel clamp VR INOX A2 steel clamp VR INOX A2 steel clamp VR INOX A2 steel clamp VR INOX A2 steel clamp VR INOX A2 steel clamp VR INOX A2 steel clamp VR INOX A2 steel clamp VR INOX A2 steel clamp VR INOX A2 steel clamp VR INOX A2 steel clamp VR INOX A2 steel clamp VR INOX A2 steel clamp VR INOX A2 steel clamp VR INOX A2 steel clamp VR INOX A2 steel clamp VR INOX A2 steel clamp
304
16-20 18-24 25-30 30-36 38-44 44-50 56-62 76-80 90-100 100-110 110-120 125-130 140-150 152-160 180 200 220 250 300 350 400
Nominal diameter
ExD
M x Lp mm
Side screws
3/8 1/2 3/4 1” 1” 1/4 1” 1/2 2” 2” 1/2 3” 100-110 4” 125-130 5” 6” 180 200 220 250 300 350 400
20x1,5 20x1,8 20x1,8 20x1,8 20x1,8 20x1,8 20x1,8 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 30x1,5 30x1,5 30x1,5 30x1,5 30x2 30x2
M8 M8 M8 M8 M8 M8 M8 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10
6x20 6x20 6x20 6x20 6x20 6x20 6x20 6x30 6x40 6x40 6x40 6x40 6x40 6x40 6x30 6x30 6x30 6x30 6x30 6x30 6x30
do x Lt mm
h1 mm
cladding and pipe fixings
VRM INOX A2 Stainless steel clamp with wall plastic plug and double threaded screw
3210 3211 3212 3213 3214 3215 3216 3217 3218 3222 3219 3220 3221 3223 3227 3224 3228 3225 3226
3/8 VRM INOX A2 SS with plug 16-20 1/2 VRM INOX A2 SS with plug 18-24 3/4 VRM INOX A2 SS with plug 25-30 1” VRM INOX A2 SS with plug 30-36 VRM INOX A2 SS with plug 38-44 1” 1/4 VRM INOX A2 SS with plug 44-50 1” 1/2 2” VRM INOX A2 SS with plug 56-62 VRM INOX A2 SS with plug 76-80 2” 1/2 3” VRM INOX A2 SS with plug 90-100 VRM INOX A2 SS with plug 100-110 100-110 4” VRM INOX A2 SS with plug 110-120 VRM INOX A2 SS with plug 125-130 125-130 5” VRM INOX A2 SS with plug 140-150 6” VRM INOX A2 SS with plug 152-160 180 VRM INOX A2 SS with plug 180 200 VRM INOX A2 SS with plug 200 220 VRM INOX A2 SS with plug 220 250 VRM INOX A2 SS with plug 250 300 VRM INOX A2 SS with plug 300
20x1,5 20x1,8 20x1,8 20x1,8 20x1,8 20x1,8 20x1,8 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 30x1,5 30x1,5 30x1,5 30x1,5
M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120
A2 INOX 6x20 6x20 6x20 6x20 6x20 6x20 6x20 6x30 6x40 6x40 6x40 6x40 6x40 6x40 6x30 6x30 6x30 6x30 6x30
10x60 10x60 10x60 10x60 10x60 10x60 10x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60
80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80
304
do = Hole diameter h1 = Min. hole depth Lt = Anchor length Lp = Pin length ExD = Width x thickness M = Thread
• always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation VRM - VR Pipe size daN Axial recommended load 1 daN≃1 kg 3/8” 1/2” - 2” 2 1/2” - 300 350 - 400
70 80 70 80
366
cladding and pipe fixings
Vorpa CDS GAS - VRP - CDG Steel pipe clamp
concrete
natural stone
solid brick
products group Suitable for • concrete • natural stone • solid brick
VRP steel clamp with wall plastic plug and double threaded screw
To fix • industrial plants • plumbing and heating systems • run water vapor systems
Steel clamp for PVC and polyethylene pipes
CDG steel clamp with welded nut
CDS steel clamp with 1/2” welded nut
product code and technical data CDS steel clamp with 1/2” welded nut Description
1779 781 782 783 784 757 785 786 788 787 789 793 758 758S
CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS
40 50 63 76-80 90-100 100-110 110-120 125-130 140-150 152-160 200 250 300 315
Nominal diameter
ExD mm
M thread
Side screws
40 50 63 76 - 2”1/2” 90 - 3” 100 - 110 4” 125 - 130 5” 6” 200 250 300 315
30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5
1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2”
M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6
cladding and pipe fixings
Code
Examples of applications
CDS 1/2” GAS Pipe size daN Axial recommended load 1 daN≃1 kg 40 - 315
300
367
cladding and pipe fixings
Vorpa CDS GAS - VRP - CDG Steel pipe clamp
concrete
natural stone
solid brick
installation sequence
Clean the hole before the installation
product code and technical data CDG steel clamp with welded nut Code
Description
1480 481 482 483 484 476 485 486 488 487 1487 489 1489 1490 1491
CDG steel clamp CDG steel clamp CDG steel clamp CDG steel clamp CDG steel clamp CDG steel clamp CDG steel clamp CDG steel clamp CDG steel clamp CDG steel clamp CDG steel clamp CDG steel clamp CDG steel clamp CDG steel clamp CDG steel clamp
40 50 63 76 90 100 110 125 140 160 180 200 220 250 300
Nominal diameter
ExD mm
M thread
Side screws
40 50 63 76 90 100 110 125 140 160 180 200 220 250 300
29x2,3 29x2,3 29x2,3 29x2,3 29x2,3 29x2,3 29x2,3 29x2,3 29x2,3 29x2,3 29x2,3 29x2,3 29x2,3 29x2,3 29x2,3
M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10
M6x20 M6x20 M6x20 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25
do = Hole diameter h1 = Min. hole depth Lt = Anchor length Lp = Pin length ExD = Width x thickness M = Thread
cladding and pipe fixings
VRP steel clamp with wall plastic plug and double threaded screw Code
Description
4460 461 462 463 464 460 465 466 468 467 1470 469 1471 470 471
VRP steel clamp/plug 40 VRP steel clamp/plug 50 VRP steel clamp/plug 63 VRP steel clamp/plug 76 VRP steel clamp/plug 90 VRP steel clamp/plug 100 VRP steel clamp/plug 110 VRP steel clamp/plug 125 VRP steel clamp/plug 140 VRP steel clamp/plug 160 VRP steel clamp/plug 180 VRP steel clamp/plug 200 VRP steel clamp/plug 220 VRP steel clamp/plug 250 VRP steel clamp/plug 300
Nominal diameter
ExD mm
dox Lt mm
h1 mm
Lp mm
Side screws
40 50 63 76 90 100 110 125 140 160 180 200 220 250 300
29x2,3 29x2,3 29x2,3 29x2,3 29x2,3 29x2,3 29x2,3 29x2,3 29x2,3 29x2,3 29x2,3 29x2,3 29x2,3 29x2,3 29x2,3
12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60
75 75 75 75 75 75 75 75 75 75 75 75 75 75 75
M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120
M6x20 M6x20 M6x20 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25
• always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation VRP - CDG Pipe size daN Axial recommended load 1 daN≃1 kg 40 - 300
180
368
cladding and pipe fixings
Vorpa CDG M8 non standard model Steel pipe clamp
concrete
natural stone
solid brick
products group
CDG-A zincplated rounded steel clamp
To fix • zincplated drain pipes • painted drain pipes
Suitable for • concrete • natural stone • solid brick
CDG-B plastic coated rounded steel clamp
Steel clamp for drain pipes CDG squared steel clamp
• always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
product code and technical data Code
Description
Pipe size
ExD band size mm
M nut thread
Side screws mm
CDG-A zincplated CDG-A zincplated CDG-A zincplated
Ø100 Ø120 Ø150
Ø100 Ø120 Ø150
32x1,5 32x1,5 32x1,5
M8 M8 M8
M8x20 M8x20 M8x20
218 249 215
CDG-B grey RAL 7024 CDG-B brown RR 32 CDG-B red RR 29
Ø100 Ø100 Ø100
Ø100 Ø100 Ø100
32x1,5 32x1,5 32x1,5
M8 M8 M8
M8x20 M8x20 M8x20
100x70 100x70 100x70 100x70
32x1,5 32x1,5 32x1,5 32x1,5
M8 M8 M8 M8
M8x20 M8x20 M8x20 M8x20
1166 22952 22953 1170
CDG CDG CDG CDG
zincplated grey RAL 7024 red RR 32 brown RR 29
100x70 100x70 100x70 100x70
cladding and pipe fixings
228 229 235
Examples of applications
CDG M8 non standard model Pipe size daN Axial recommended load 1 daN≃1 kg Ø100 - Ø120 - Ø150 - 100x70
140
369
cladding and pipe fixings
Vorpa CAV - CAV inox A2 Steel pipe clamp
concrete
natural stone
solid brick
products group To fix • industrial plants • plumbing and heating systems • run water vapor systems
Suitable for • concrete • natural stone • solid brick
CAV TOP with TOP anchor, welded nut and double threaded screw
Steel clamp for pipes and flues Ideal corrosion protection
*
CAV INOX A2 TOP with stainless steel TOP anchor, welded nut and double threaded screw
A2 INOX 304
*
installation sequence
Clean the hole before the installation
cladding and pipe fixings
Examples of applications
370
cladding and pipe fixings
Vorpa CAV - CAV inox A2 Steel pipe clamp
concrete
natural stone
solid brick
product code and technical data CAV TOP with TOP anchor, welded nut and double threaded screw Code
7391 7392 7393 7394 7395 7396 7451 7452 7453 7454 7450 7455 7456 7458 7457 71457 7459 71459 71460 71461
Description
CAV 18-24 CAV 25-30 CAV 30-36 CAV 38-44 CAV 44-50 CAV 56-62 CAV 50 CAV 63 CAV 76-80 CAV 90-100 CAV 100 CAV 110-120 CAV 125 CAV 140-150 CAV 152-160 CAV 180 CAV 200 CAV 220 CAV 250 CAV 300
Nominal diameter
ExD mm
do x Lt mm
h1 mm
1/2 3/4 1” 1” 1/4 1” 1/2 2” 50 63 2” 1/2 3” 100 4” 125 5” 6” 180 200 220 250 300
20 X 2,5 20 X 2,5 20 X 2,5 20 X 2,5 20 X 2,5 20 X 2,5 29 X 2,3 29 X 2,3 29 X 2,3 29 X 2,3 29 X 2,3 29 X 2,3 29 X 2,3 29 X 2,3 29 X 2,3 29 X 2,3 29 X 2,3 29 X 2,3 29 X 2,3 29 X 2,3
12 x 51 12 x 51 12 x 51 12 x 51 12 x 51 12 x 51 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60
60 60 60 60 60 60 70 70 70 70 70 70 70 70 70 70 70 70 70 70
M x Lp mm
Side screws
M8x100 M8x100 M8x100 M8x100 M8x100 M8x100 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110
M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25
CAV INOX A2 TOP with stainless steel TOP anchor, welded nut and double threaded screw
CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX
16-20 18-24 25-30 30-36 38-44 44-50 56-62 76-80 90-100 100-110 110-120 125-130 140-150 152-160 180 200 220 250 300 350 400
3/8 1/2 3/4 1” 1” 1/4 1” 1/2 2” 2” 1/2 3” 100-110 4” 125-130 5” 6” 180 200 220 250 300 350 400
20x1,5 20x1,8 20x1,8 20x1,8 20x1,8 20x1,8 20x1,8 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 30x1,5 30x1,5 30x1,5 30x1,5 30x2 30x2
60 60 60 60 60 60 60 70 70 70 70 70 70 70 70 70 70 70 70 70 70
12 x 51 12 x 51 12 x 51 12 x 51 12 x 51 12 x 51 12 x 51 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60
A2 INOX 304
M8x100 M8x100 M8x100 M8x100 M8x100 M8x100 M8x100 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110
M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x30 M6x40 M6x40 M6x40 M6x40 M6x40 M6x40 M6x30 M6x30 M6x30 M6x30 M6x30 M6x30 M6x30
cladding and pipe fixings
3540 3541 3542 3543 3544 3545 3546 3553 3554 3555 3556 3557 3558 3559 3563 3560 3564 3561 3562 3565 3566
do = Hole diameter h1 = Min. hole depth Lt = Anchor length Lp = Pin length ExD = Width x thickness M = Thread
• always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation CAV - CAV INOX A2 Pipe size
daN
Axial recommended load 1 daN≃1 kg CAV 50 - 300 180 CAV INOX A2 3/8” - 400 120
371
cladding and pipe fixings
Vorpa CFZ White or black plastic-coated steel pipe clamp
concrete
solid brick
perforated brick
aerated poroton
products group To fix • air ducts • flues, smoking pipes
Suitable for • concrete • solid brick • perforated brick • aerated poroton • perforated cement
CFZ WHITE plastic-coated
CFZ BLACK plastic-coated
Plastic-coated steel clamp for smoking pipes
product code and technical data
CFZ WHITE plastic-coated Code
Description
Nominal diameter
2406 800 794 2485 2486 2488 2487
CFZ white 60 60 CFZ white 76-80 76-80 CFZ white 100 100 CFZ white 110-120 110-120 CFZ white 125-130 125-130 CFZ white 140-150 140-150 CFZ white 160 160
ExD mm
do x Lt mm
24x2,2 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5
10 x 80 10 x 80 10 x 80 10 x 80 10 x 80 10 x 80 10 x 80
24x1,5 24x1,5
10 x 80 10 x 80
h1 mm
M x Lp mm
Li mm
Side screws
85 85 85 85 85 85 85
M 8x200 M 8x200 M 8x200 M 8x200 M 8x200 M 8x200 M 8x200
150 158 170 175 182 190 200
M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25
85 85
M 8x200 M 8x200
158 170
M6x25 M6x25
cladding and pipe fixings
CFZ BLACK plastic-coated
800N 794N
CFZ black 76-80 CFZ black 100
76-80 100
• always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation Examples of applications
372
do = Hole diameter h1 = Min. hole depth Lt = Anchor length Lp = Pin length ExD = Width x thickness Ø = Pipe Li = Axial spacing M = Thread
perforated cement
cladding and pipe fixings
Vorpa CFI INOX A2 Steel pipe clamp
concrete
solid brick
perforated brick
aerated poroton
perforated cement
products group To fix • flues • air ducts • industrial plants • run water vapor system • exhaust fumes • smoking pipes
Suitable for • concrete • solid brick • perforated brick CFI INOX A2 stainless steel clamp • aerated poroton • perforated cement
A2 stainless steel clamps for iron pipes, flues, air ducts
A2 INOX 304
Ideal corrosion protection
product code and technical data
CFI INOX A2 stainless steel clamp Description
Nominal diameter
2771 2772 2773 2774 2775 2776 2777 2778 2779 2780 2781
CFI INOX 76-80 76-80 CFI INOX 1 00 100 CFI INOX 1 10-120 110-120 CFI INOX 1 25-130 125-130 CFI INOX 1 40-150 140-150 CFI INOX 1 60 160 CFI INOX 1 80 180 CFI INOX 2 00 200 CFI INOX 2 20 220 CFI INOX 2 50 250 CFI INOX 3 00 300
ExD mm
do x Lt mm
h1 mm
M x Lp mm
Li mm
Side screws
24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 30x1,5 30x1,5 30x1,5 30x1,5 30x1,5
10 x 80 10 x 80 10 x 80 10 x 80 10 x 80 10 x 80 12 x 74 12 x 74 12 x 74 12 x 74 12 x 74
85 85 85 85 85 85 85 85 85 85 85
M8x200 M8x200 M8x200 M8x200 M8x200 M8x200 M10x180 M10x180 M10x180 M10x180 M10x180
158 170 175 182 190 200 210 220 230 245 270
M6x30 M6x30 M6x40 M6x40 M6x40 M6x30 M6x30 M6x30 M6x30 M6x30 M6x30
• always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
Examples of applications
373
do = Hole diameter h1 = Min. hole depth Lt = Anchor length Lp = Pin length Li = Axial spacing ExD = Width x thickness Ø = Pipes M = Thread
cladding and pipe fixings
Code
cladding and pipe fixings
Vorpa CP Light steel drain pipe clamp
concrete
natural stone
solid brick
products group
CP TONDO rounded clamp
To fix • drain pipes
Suitable for • concrete • natural stone • solid brick
• double threaded M8 screws and nylon plug VN 10x60 • 3 different versions available • always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation CP QUADRO squared clamp
Steel clamp for drain pipes product code and technical data CP TONDO rounded clamp Code Description
do mm
h1 mm
Lp mm
Side screws
Ø mm
ExD mm
Ø60 Ø80 Ø100 Ø120 Ø80 Ø100 Ø80 Ø100
60 60 60 60 60 60 60 60
10 10 10 10 10 10 10 10
70 70 70 70 70 70 70 70
M 8x75 M 8x75 M 8x75 M 8x75 M 8x75 M 8x75 M 8x75 M 8x75
M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20
60 80 100 120 80 100 80 100
28x1,5 28x1,5 28x1,5 28x1,5 28x1,5 28x1,5 28x1,5 28x1,5
CP squared zincplated 80x80 CP squared zincplated 100x100 CP squared dark brown 80x80 CP squared dark brown 100x100 CP squared copper 80x80 CP squared copper 100x100
60 60 60 60 60 60
10 10 10 10 10 10
70 70 70 70 70 70
M 8x75 M 8x75 M 8x75 M 8x75 M 8x75 M 8x75
M6x20 80x80 28x1,5 M6x20 100x100 28x1,5 M6x20 80x80 28x1,5 M6x20 100x100 28x1,5 M6x20 80x80 28x1,5 M6x20 100x100 28x1,5
CP rounded zincplated CP rounded zincplated CP rounded zincplated CP rounded zincplated CP rounded dark brown CP rounded dark brown CP rounded copper CP rounded copper
cladding and pipe fixings
CP QUADRO squared clamp
501 502 505 506 508 509
Examples of applications
374
do = Hole diameter h1 = Min. hole depth Lt = Anchor length Lp = Pin length ExD = Width x thickness Ø = Pipe
cladding and pipe fixings
494 491 492 493 495 496 498 499
Lt mm
cladding and pipe fixings
Vorpa VCR Light copper pipe clamp
concrete
natural stone
solid brick
products group To fix • light copper pipes
Suitable for • concrete • natural stone • solid brick
VCR T copper light clamp with plastic wall plug VN and double threaded copper screw
VN R plastic wall plug VN with double threaded copper screw
Light copper clamp
VCR copper light clamp with pre-assembled side • always check load bearing capacity values in the table screw • respect the installation data
• clean the hole before the installation
product code and technical data
VCR T light copper clamp with plastic wall plug VN and double threaded copper screw Code
Description
5400 5401 5402 5403 5404 5405 5406 5407 5409 5408 5410 5411
VCR T 10 VCR T 12 VCR T 14 VCR T 16 VCR T 18 VCR T 22 VCR T 28 VCR T 32 VCR T 35 VCR T 38 VCR T 42 VCR T 54
Thread
Lt mm
do mm
h1 mm
Øv xLv side mm screws
Ø mm
ExD lower portion (mm)
ExD upper portion (mm)
M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6
30 30 30 30 30 30 30 30 30 30 30 30
6 6 6 6 6 6 6 6 6 6 6 6
40 40 40 40 40 40 40 40 40 40 40 40
6x30 6x30 6x30 6x30 6x30 6x30 6x30 6x30 6x30 6x30 6x30 6x30
M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5
10 12 14 16 3/8” - 18 1/2” - 22 3/4” - 28 1” - 32 35 38 42 54
15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 16x1,2 16x1,2
10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 12x0,9 12x0,9
M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5
10 12 14 16 3/8” - 18 1/2” - 22 3/4” - 28 1” - 32 35 38 42 54
15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 16x1,2 16x1,2
10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 12x0,9 12x0,9
v
Lt
do = Hole diameter h1 = Min. hole depth Lt = Plug length Lv = Screw length ExD = Width x thickness Ø = Pipe Øv = Screw diameter
VN R plastic wall plug VN with double threaded copper screw
4768
VN R 6x30
M6
30
6
40
6x30
VCR copper light clamp with pre-assembled side screw
VCR copper light clamp 10 VCR copper light clamp 12 VCR copper light clamp 14 VCR copper light clamp 16 VCR copper light clamp 18 VCR copper light clamp 22 VCR copper light clamp 28 VCR copper light clamp 32 VCR copper light clamp 35 VCR copper light clamp 38 VCR copper light clamp 42 VCR copper light clamp 54
Examples of applications
375
cladding and pipe fixings
4400 4401 4402 4403 4404 4405 4406 4407 4409 4408 4410 4411
cladding and pipe fixings
Vorpa CT Light steel pipe clamp
concrete
natural stone
products group To fix • light steel pipes
Suitable for • concrete • natural stone • solid brick
Light steel clamp VN V plastic wall plug VN with double threaded screw
CT steel clamp with nylon wall plug VN V 8x40 and double threaded screw
• always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
product code and technical data
cladding and pipe fixings
CT steel clamp with nylon wall plug VN V 8x40 and double threaded screw Code
Description
1400 1401 1402 1403 1404 1405 1406 1407 1408 1409 1410 1415 1411 1412 1413 1414
CT light clamp CT light clamp CT light clamp CT light clamp CT light clamp CT light clamp CT light clamp CT light clamp CT light clamp CT light clamp CT light clamp CT light clamp CT light clamp CT light clamp CT light clamp CT light clamp
10 12 14 16 18 20 22 24 26 28 32 35 38 42 48 50
Side screws
Øt mm
M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5
10 12 14 16 18 20 22 24 26 28 32 35 38 42 48 50
ExD ExD Thread lower portion upper portion (mm) (mm)
15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 16x1,2 16x1,2 16x1,2
Lt mm
do h1 Øv xLv mm mm mm
10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 12x0,9 12x0,9 12x0,9
Lt
do = Hole diameter h1 = Min. hole depth Lt = Plug length Lv = Screw length ExD = Width x thickness Ø = Pipe Øv = Screw diameter
VN V plastic wall plug VN with double threaded screw
768
VN V nylon plug/double screw 8x40
v
M6
Examples of applications
376
40
8
50
6x40
solid brick
cladding and pipe fixings
Vorpa KP Nylon clip for pipes and cables products group To fix • metric insulation pipes • cable
Suitable for • nylon plug Ø6 KP nylon clip
product information Characteristics • plastic clip with an upper part suitable for pipes saddle, can be installed with a light-weight anchor • made of polypropylene colour Grey RAL 7035 • flammability rating: UL 94-HB • a side hook for connecting other pipe saddles in series
• cables: Ø mini 8 - Ø maxi 60 • raw Material: Polyamid 6 • burning properties: according to IEC 60695-2-12 (GWFI): 650°C • colour: Grey, RAL 7035 • installation temperature: -5°C / +40°C • working temperature: -30°C / +65°C
installation sequence e technical data
Clean the hole before the installation
Description
1190 1191 1192 1193 1194 1195 1196 1197
KP 8 KP 10 KP 16 KP 20 KP 25 KP 32 KP 40 KP 50
Ø mim mm
Ø max mm
Resistance of the top part opening daN
4 8 12 16 20 25 32 40
8 12 16 23 25 32 40 60
10 10 23 20 25 31 40 50
KP A (mm) A1 (mm) B (mm) C (mm D (mm) E (mm) F (mm) G (mm) H (mm)
Examples of applications
377
8 8,05 9,7 16,85 11,75 16,7 4,9 17,2 4 18,95
10 10,6 11,8 16,8 12 21,8 4,9 17,2 4 24,05
16 14,25 15,3 16,25 18,6 26,75 4,9 16,9 3,9 29,2
20 16,3 17,45 15,75 22,45 31 4 16,65 3,9 33,4
25 18,2 19,7 15,9 25,3 34,7 4,85 17 3,85 37,2
32 23,8 25,15 15,6 34,6 45,6 4,8 17 4 47,85
40 27,8 28,8 15,45 44,15 55,1 4,85 16,95 4,1 57,35
50 35,2 37 15,45 57,3 69,35 4,9 17,15 4,1 71,6
cladding and pipe fixings
Code
cladding and pipe fixings
Vorpa KPO Plastic clip for fixing metric insulation pipes products group To fix • metric insulation pipes • cable
Suitable for • nylon plug Ø6 KPO plastic clip
product information Characteristics • plastic clip for fixing or protecting rigid, metric insulating pipes in electrical installations, on vertical or horizontal surfaces (from Ø 16 to 50 mm) • can be installed with a light-weight anchor • rounded shape to facilitate pipe accomodiation, elongated hole for adjusting wall fixings • side hook for connecting other pipe clamps in series, guide for laying in raceways
• cables: Ø mini 16 - Ø maxi 50 • raw Material: Polypropylen • burning properties: according to IEC 60695-2-12 (GWFI): 650°C • colour: Grey, RAL 7035 • installation temperature: -5°C / +35°C • working temperature: -30°C / +55°C
installation sequence e technical data
cladding and pipe fixings
Clean the hole before the installation
Code Description Ø pipe mm
Dc mm
X mm
C Width Axial load Axial load mm mm retention daN insertion daN
2190 2191 2192 2193 2194 2195
15 19 24 30 38 48
10,5 12,5 15,0 20,0 25,0 32,5
17,5 19,5 22,0 26,5 30,4 35,4
KPO 16 KPO 20 KPO 25 KPO 32 KPO 40 KPO 50
16 20 25 32 40 50
16 16 16 16 16 16
8 9 9 6 7 5
KPO A (mm) B (mm) D (mm) F (mm G (mm) H (mm) I (mm) L (mm)
6 7 6 9 7 7
Examples of applications
378
Ø 16 15 26,9 22 16,1 4 9,1 10,4 27,1
Ø20 19 29,3 28,1 16,1 4 9,1 10,9 32,8
Ø25 24 35,55 34,2 16,1 4 9,1 11,1 39,1
Ø32 30 43,5 41,2 16,1 4 9,1 10,7 46,2
Ø40 38 49,7 48,1 16,1 4 9,1 10,4 53,1
Ø50 48 58,5 59,2 16,1 4 9,1 10,4 64,4
cladding and pipe fixings
Vorpa TC Nylon clip with plug and screw products group To fix • metric insulation pipes • cable
Suitable for • nylon plug Ø6
TC nylon clip
According to EN 50146
product information Characteristics • nylon cable tie for plastic and metal pipe • cables: Ø min 16 - Ø maxi 63 • raw Material: Polyammide • burning properties: according to IEC 60695-2-12 (GWFI): 650°C • colour: Grey, RAL 7035 • installation temperature: -5°C/+35°C • working temperature: -40°C/+70°C
• flammability rating: UL 94-HB • plastic cable for fixing or protecting rigid, metric insulating pipes in electrical installations, on vertical or horizontal surfaces (from Ø 16 to 63 mm) • can be installed with a light-weight anchor Suggestion for use • the use of plastic anchors is not recommended for permanent suspended loading applications
installation sequence
Clean the hole before the installation
product code and technical data C
Code
Description
2400 2401
TC for pipes Ø6 - Ø32 TC for pipes Ø40 - Ø63
do = hole diameter for screw
TC nylon clip
D B
do mm
A mm
B mm
C mm
D mm
Working temperature
Installation temperature
Resistance of the cable tie opening Kg
6 6
17.6 17.6
24.5 40.5
180 280
5.9 5.9
-40°C / +70°C -40°C / +70°C
-5°C / +35°C -5°C / +35°C
36 36
Examples of applications
379
cladding and pipe fixings
A
cladding and pipe fixings
Vorpa TC Nylon clip with plug and screw
concrete
natural stone
solid brick
perforated brick
perforated cement
products group
TC1 single nylon clip
Suitable for • concrete • natural stone • solid brick • perforated brick • perforated cement
To fix • metric insulation pipes • cable
TC2 double nylon clip
product information Characteristics • nylon clip with plug and screw • double version available • installation temperature: +5°C / +40°C • working temperature: -40°C / +40°C (max +80°C fot short period)
Suggestion for use • The use of plastic anchors is not recommended for permanent suspended loading applications above 40°C
Clean the hole before the installation
installation sequence Single clip TC 1
cladding and pipe fixings
Double clip TC 2
Examples of applications
380
cladding and pipe fixings
Vorpa TC Nylon clip with plug and screw
concrete
natural stone
solid brick
perforated brick
perforated cement
product code and technical data
TC1 single nylon clip
Code
Description
dv xLv mm
do mm
hmin mm
h1 mm
hef mm
Ø mm
1090 1091 1092 2868 1093 1094 1095 1096 1097 1098 1100
TC1 10 TC1 12 TC1 14 TC1 15 TC1 16 TC1 18 TC1 20 TC1 22 TC1 24 TC1 26 TC1 28
3,5x35 3,5x35 4x45 4x45 4x45 4,5x50 4,5x50 4,5x50 6x60 6x60 6x60
5 5 6 6 6 8 8 8 10 10 10
30 30 50 50 50 60 60 60 80 80 80
30 30 35 35 35 45 45 45 50 50 50
20 20 25 25 25 30 30 30 40 40 40
10 12 14 15 16 18 20 22 24 26 28
do = Hole diameter h1 = Min. hole depth Lt = Plug length Lv = Screw length Ø = Pipes hef = Effective embedment depth dv = Screw diameter hmin = Minimum thickness of the fixture
TC2 double nylon clip
Description
dv xLv mm
do mm
hmin mm
h1 mm
hef mm
Ø mm
2090 2091 2092 2867 2093 2094 2095 2096 2100
TC2 10 TC2 12 TC2 14 TC2 15 TC2 16 TC2 18 TC2 20 TC2 22 TC2 28
4,5x50 4,5x50 4,5x50 4,5x50 4,5x50 6x60 6x60 6x60 6x60
8 8 8 8 8 10 10 10 10
60 60 60 60 60 80 80 80 80
60 60 60 60 60 70 70 70 70
30 30 30 30 30 40 40 40 40
10 12 14 15 16 18 20 22 28
cladding and pipe fixings
Code
ATTENTION: An appropriate safety factor ≥ 6 should be applied on these values
TC1 - TC2 Substrate materials TC1 10÷12 TC1 14÷16 TC1 18÷22 TC1 24÷28 TC2 10÷16 TC2 18÷28 Pull out values in daN 1 daN≃1 kg Perforated brick Double brick UNI Concrete C20/25
30 42 54
48 78 90
72 84 96
381
96 120 180
72 84 96
96 120 180
cladding and pipe fixings
Vorpa CLIPS Clips for rigid conduits products group HEAVY CLIPS
LIGHT CLIPS
SFT 1 zincplated SFT 2 zincplated SFZ - hotdipped galvanized heavy clip with double hole heavy clip with single hole
SL 1 zincplated SL 2 zincplated light clip with single hole light clip with double hole
• rigid conduits / cable • tubes for installations • SPS clips suitable for road-signs
ANTIROTATION PROTUBERANCE CLIPS
SPS2 zincplated heavy clip with antirotation protuberance with double hole
SPS 3 zincplated heavy clip with antirotation protuberance with double hole
installation sequence
Clean the hole before the installation
product code and technical data HEAVY CLIP WITH ANTIROTATION PROTUBERANCE 2 HOLES - HEAVY CLIP
Code Description
A mm
B mm
C mm
E mm
F mm
Øt mm
357S SPS2 60
25
2,2
Ø 8,5
11
100
Ø 60
SPS3 zincplated heavy clip with antirotation protuberance with double hole Code Description
360 SPS3 60
A = Width B = Thickness CxE = Hole dimension F = Distance Øt = Pipes
2 HOLES - HEAVY CLIP
A mm
B mm
C mm
F mm
Øt mm
20
3,0
Ø9
102
Ø 60
90°
Øt
cladding and pipe fixings
SPS2 zincplated heavy clip with antirotation protuberance with double hole
10
F E
A
Examples of applications
382
cladding and pipe fixings
Vorpa CLIPS Clips for rigid conduits product code and technical data SFT 1 zincplated heavy clip with single hole - ideal for plumbing Code
Description
338 339 340 341 342 343 344 345 346 347
SFT1 1 foro SFT1 1 foro SFT1 1 foro SFT1 1 foro SFT1 1 foro SFT1 1 foro SFT1 1 foro SFT1 1 foro SFT1 1 foro SFT1 1 foro
10 12 14 3/8” 1/2” 3/4” 1” 1”1/4 1”1/2 2”
1 HOLE - HEAVY CLIP
A mm
B mm
C mm
E mm
F mm
Øt mm
14 16 18 20 22 23 24 24 25 25
1,2 1,2 1,5 1,8 1,8 2,0 2,0 2,2 2,2 2,2
5 5 5 6 6 6 8,5 8,5 8,5 8,5
8 8 8 10 10 10 11 11 11 11
18 20 20 25 28 30 35 40 45 50
10 12 14 3/8” 1/2” 3/4” 1” 1”1/4 1”1/2 2”
SFZ hotdipped galvanized heavy clip with single hole - ideal for light poles and telephone poles
341ZC 342ZC 343ZC 344ZC 345ZC 346ZC 347ZC
SFZ 1 foro 3/8” SFZ 1 foro 1/2” SFZ 1 foro 3/4” SFZ 1 foro 1” SFZ 1 foro 1”1/4 SFZ 1 foro 1”1/2 SFZ 1 foro 2”
20 22 23 24 24 25 25
1,8 1,8 2,0 2,0 2,2 2,2 2,2
6 6 6 8 8 8 8
1 HOLE - HEAVY CLIP
10 10 10 11 11 11 11
25 28 30 35 40 45 50
6,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5
14 17 18 20 22 24 26 28 33 46 53
3/8” 1/2” 3/4” 1” 1”1/4 1”1/2 2” 1 HOLE - LIGHT CLIP
SL 1 zincplated light clip with single hole - ideal for electrical rigid conduits
3338 3339 3340 3341 3342 3343 3344 3345 3346 3347 3348
SL1 1 foro SL1 1 foro SL1 1 foro SL1 1 foro SL1 1 foro SL1 1 foro SL1 1 foro SL1 1 foro SL1 1 foro SL1 1 foro SL1 1 foro
7 10 12 16 20 22 26 28 32 38 50
10 14 14 14 14 14 14 14 15 15 15
0,9 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,8 1,8 1,8
4,5 6,5 6,5 6,5 6,5 6,5 6,5 6,5 6,5 6,5 6,5
SFT2 2 fori SFT2 2 fori SFT2 2 fori SFT2 2 fori SFT2 2 fori SFT2 2 fori SFT2 2 fori SFT2 2 fori
3/8” 1”1/2 3/4” 1” 1”1/4 1”1/2 2” 2”1/2
15 22 23 23 24 24 25 30
1,5 2,0 2,0 2,2 2,2 2,2 2,2 2,2
6 8 8 8 8,5 8,5 8,5 Ø10
2 HOLES - HEAVY CLIP
10 10 10 10 11 11 11 Ø10
50 56 60 70 80 90 100 130
SL 2 zincplated light clip with double hole - ideal for electrical rigid conduits
3352 3353 3354 3355 3356 3357 3358 3359 3360 3361
SL2 2 fori SL2 2 fori SL2 2 fori SL2 2 fori SL2 2 fori SL2 2 fori SL2 2 fori SL2 2 fori SL2 2 fori SL2 2 fori
10 13 16 19 22 26 28 32 38 50
10 10 12 12 14 14 14 14 14 14
0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9
5 5 5 5 6,5 6,5 6,5 6,5 6,5 6,5
7-8 10-11 12-13 16-17 19-20 21-22 25-26 28-30 31-32 38-40 50 cladding and pipe fixings
SFT 2 zincplated heavy clip with double hole - ideal for plumbing
351 352 353 354 355 356 357 358
A = Width B = Thickness CxE = Hole dimension F = Distance Øt = Pipes
3/8” 1/2” 3/4” 1” 1”1/4 1”1/2 2” 2”1/2
2 HOLES - LIGHT CLIP
Ø5 Ø5 6,5 6,5 8,5 8,5 8,5 10 10 10
383
31 32 34 38 41 47 50 54 61 80
10 13 16 19 22 26 28 32 38 50
A = Width B = Thickness CxE = Hole dimension F = Distance Øt = Pipes
cladding and pipe fixings
Vorpa BANDING IN ROLL Banding for pipe applications products group To fix • flues • traffic signs • vertical PVC downpipes
Zincplated/A2 SS banding
*
Cloth banding
A2 INOX Steel nail
304
Striker
*
product information Characteristics • zincplated and cloth banding for pipe applications • ideal for vertical PVC downpipes, parallel conducts and suspended installations
• easy installation • available in ondulated zincplated version and in resistant cloth Suggestion for use • always check load bearing capacity • respect the installation data
product code and technical data Zincplated/A2 SS banding
cladding and pipe fixings
Code
52361 421 * 419 52368
Description
Lenght mt
Ø hole mm
A mm
B mm
C mm
Zincplated banding 12 Zincplated banding 17 A2 SS banding 17
10 10 10
5 7 7
12 17 17
0,7 0,7 0,8
9 20 20
Cloth banding 15
15
15
1
Steel nail and striker Code
52366 52367 52365
Description
Steel nail 18 Steel nail 22 Striker
Ø nail mm
E mm
L mm
4,2 4,2
26 30
18 22
Examples of applications
384
cladding and pipe fixings
Vorpa U-BOLT Heavy duty pipe clamp according to the regulation 2002/95/CE (RoHS) products group
*
To fix • clamping circular section elements of various sizes
U-BOLT U-BOLT INOX A2 Special U-shaped threaded screw with ISO metric thread
Accessories • N° 2 hexagonal nuts UNI 5588 class 8. • N° 2 plain washers UNI 6592 class 100HV
A2 INOX 304
*
product code and technical data Code zincplated
55800 55202 55203 55209 55801 5233 5223 55206 55204 55802 55207 55803 55211 55804
Description
h mm
b mm
e mm
a mm
d1 mm
d2 mm
d3 mm
U-BOLT 18 U-BOLT 22 U-BOLT 27 U-BOLT 34 U-BOLT 43 U-BOLT 49 U-BOLT 61 U-BOLT 77 U-BOLT 89 U-BOLT 102 U-BOLT 115 U-BOLT 140 U-BOLT 168 U-BOLT 220
37 43 47 55 63 73 85 101 113 130 142 169 202 254
19 25 25 25 25 30 30 30 30 35 35 35 45 45
24 28 33 40 49 57 69 85 97 110 123 148 178 230
18 22 27 34 43 49 61 77 89 102 115 140 168 220
3/8” 1/2” 3/4” 1” 1”1/4” 1”1/2” 2” 2”1/2” 3” 3”1/2” 4” 5” 6” 8”
5,3 5,3 5,3 5,3 5,3 7,1 7,1 7,1 7,1 7,1 7,1 7,1 8,9 8,9
M6 M6 M6 M6 M6 M8 M8 M8 M8 M8 M8 M8 M10 M10
Examples of applications
385
h b a e d1 d2 d3
= pipe clamp height = metric thread = pipe clamp width = distance = for pipe = diameter = thread
cladding and pipe fixings
5200 5201 5202 5203 5204 5205 5206 5207 5208 5209 5210 5211 5212 5213
Code A2 SS*
cladding and pipe fixings
Vorpa VT Steel rounded bracket
concrete
solid brick
perforated brick
products group VT rounded bracket
To fix • wall basins
Suitable for • concrete • solid brick • perforated brick
• always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
product code and technical data Code
Description
Lt mm
do mm
h1 mm
Øm mm
L mm
322X
VT 18/300
85
18
90
Ø20
300
ht Lt L d0
Øm
do h1 Lt Øm L
= Hole diameter = Min. hole depth = Plug length = Bracked diameter = Bracket lenght
cladding and pipe fixings
Examples of applications
VT Substrate materials Recommended values in daN 1 daN≃1 kg Concrete C20/25 Solid brick Double brick UNI with plaster
90 80 50
386
cladding and pipe fixings
Vorpa MVL Heavy duty steel bracket
concrete
natural stone
solid brick
perforated brick
products group Suitable for • concrete • natural stone • solid brick • perforated brick
MVL bracket
To fix • wall basins
Clean the hole before the installation
installation sequence
105 mm MVL 340 155 mm MVL 460
product code and technical data MVL heavy duty steel bracket Code
Description
Lt mm
do mm
h1 Øm Ch L mm mm mm mm
85 85
16 16
95 95
1801 MVL 340 1802 MVL 460
12 12
21 340 21 460
V mm
M5x30 M5x30
cladding and pipe fixings
• quick and easy assembly, high loadability • applications on every basic material • adjust the support after assembling the upper shelf by acting on the support nut Examples of applications
MVL Substrate materials MVL 340 MVL 460 Recommended values in daN 1 daN≃1 kg Concrete C20/25 Solid brick Double brick UNI with plaster
150 120 80
387
200 160 110
cladding and pipe fixings
Vorpa TVH Fixing set for water heathers
concrete
natural stone
solid brick
perforated brick
perforated cement
products group Suitable for • concrete • natural stone • solid brick • perforated brick • perforated cement
TVH with hook
To fix • boilers • water heathers
installation sequence
Clean the hole before the installation
product code and technical data
I
TVH nylon plug with zincplated heavy hook Code
244
Description
Lt mm
do mm
h1 mm
Lp mm
Øp mm
I mm
TVH 14
75
14
85
98
8,8
18
cladding and pipe fixings
• always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation do h1 L t Lp Øp l
= Hole diameter = Min. hole depth = Plug length = Hook length = Hook diameter = Distance
Examples of applications
TVH Substrate materials TVH Ø14 Recommended values in daN 1 daN≃1 kg Concrete C20/25 Double brick UNI with plaster
120 90
388
cladding and pipe fixings
Vorpa VNS Fixing set for flush tanks
concrete
natural stone
solid brick
products group Suitable for • concrete • natural stone • solid brick
VNS with hook
To fix • boilers • flush tanks
installation sequence
Clean the hole before the installation
product code and technical data
VNS nylon plug with zincplated hook Code
Description
Lt mm
do mm
h1 mm
Lp mm
Øp mm
397 398 417
VNS 8/65 VNS 10/75 VNS 10/95
60 60 60
10 12 12
75 75 75
70 75 95
8 10 10
do h1 Lt Lp Øp
= Hole diameter = Min. hole depth = Plug length = Hook length = Hook diameter
Examples of applications
VNS Substrate materials VNS 8 Ø10 VNS 10 Ø12 Recommended values in daN 1 daN≃1 kg Concrete C20/25 Double brick UNI with plaster
60 45
389
105 75
cladding and pipe fixings
• always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
cladding and pipe fixings
Vorpa TV Fixing set for wall toilets and built-in toilets
concrete
natural stone
solid brick
perforated brick
perforated cement
products group
*
TVN - TVN INOX A2 nylon bushing steel nut wall plug VN WALL TOILETS
*
TVM - TVM INOX A2 nylon bushing steel nut wall plug VH WALL TOILETS
*
TVML - TVML INOX A2 double flanged threaded nylon nuts wall plug VH BUILT-IN TOILETS
Suitable for • concrete • natural stone • solid brick • perforated brick • perforated cement
To fix • wash basins • built-in toilets • urinal
A2 INOX
304 * Clean the hole before the installation
installation sequence
TVM - TVN
On solid brick
TVML
cladding and pipe fixings
On hollow brick
Examples of applications
390
cladding and pipe fixings
Vorpa TV Fixing set for wall toilets and built-in toilets
natural stone
concrete
solid brick
perforated brick
perforated cement
product code and technical data
*
TVN - TVN INOX A2 nylon bushing - steel nut - wall plug VN
*
WALL TOILETS
*
A2 INOX 304
Code
Description
Lt mm
do mm
h1 mm
Lp mm
Øp mm
Tfix mm
205 206 207 1206
TVN 8/90 TVN 10/120 TVN 10/140 TVN 10/120 INOX A2
60 60 60 60
10 12 12 12
75 75 75 75
90 120 140 120
M8 M10 M10 M10
25 45 65 45 do h1 Lt Lp Øp Tfix
= Hole diameter = Min. hole depth = Plug length = Hook length = Hook diameter = Fixture thickness
TVN - TVN INOX A2 Substrate materials TVN 8/90 Ø10 TVN 10/120 Ø12 TVN 10/140 Ø12 Recommended values in daN 1 daN ≃ 1 kg Concrete C20/25 Double brick UNI with plaster
60 50
*
105 80
TVM - TVM INOX A2 nylon bushing - steel nut - wall plug VH
*
WALL TOILETS
*
304
Description
Lt mm
do mm
h1 mm
Lp mm
Øp mm
Tfix mm
231 2231
TVM 10/145 TVM 10/145 INOX A2
70 70
14 14
85 85
145 145
M10 M10
45 45
*
cladding and pipe fixings
TVML - TVML INOX A2 double flanged threaded nylon nuts - wall plug VH BUILT-IN TOILETS
*
A2 INOX
Code
*
100 70
A2 INOX 304
Code
Description
Lt mm
do mm
h1 mm
Lp mm
Tfix mm
232 2232
TVML 10/180 TVML 10/180 INOX A2
70 70
14 14
85 85
180 180
85 85
• always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation WALL TOILETS
BUILT-IN TOILETS
TVM - TVM INOX A2
TVML - TVML INOX A2
Substrate materials TVM 10/145 Ø14 TVML 10/80 Ø14 Recommended values in daN 1 daN≃1 kg Concrete C20/25 Double brick UNI with plaster
120 90
80 40
391
cladding and pipe fixings
Vorpa WING TOGGLE VBH M10 Universal ligth fixing for plasterboard
hollow brick plasterboard boards and panels
products group
VBH M10 Art. 5679 for suspended sanitary ware
VBG M10 Art. 5675 wing toggle M10
Suitable for • floors with alveolar core • gypsum fibra • paving in perforated blocks • metal profiling • cavity in general • cavity foor slabs made from bricks and concrete
To fix • suspended sanitary ware
Test report available
product information Characteristics • steel wing toggle with self-locking folding crosspiece inside the cavity • suitable for fixings on perforated panels, panels of gypsum-fibra, prestressed concrete with alveolar core, corrugated metal profiles, cavities in general
Suggestion for use • always consider an appropriate safety factor • check load bearing capacity values • respect the installation data
cladding and pipe fixings
installation sequence
Code
Description
5675 5679
VBG M10 WING TOGGLE VBH STUD M10x180 SANITARY WARE
Øv mm
do mm
Sc mm
Sv mm
Lv mm
M10
30
80
90
180
Sc
Sv
d0 Ø
Examples of applications
Øv do S c Sv Lv
= Screw diameter = Hole diameter = Thickness of the fixture = Interspace = Stud length
VBH M10 Recommanded loads in daN on perforated bricks (doppio UNI)
90 daN
Wing toggle VBH M10
The table shows the permissible load for tension, shear and combined tension and shear load.
392
1 daN≃1 kg
cladding and pipe fixings
Vorpa TVNC Fixing set for flush tanks
concrete
natural stone
solid brick
products group TVNC nylon bushing steel nut wall plug VN
Suitable for • concrete • natural stone • solid brick
To fix • flush tanks
installation sequence
Clean the hole before the installation
product code and technical data
TVNC nylon bushing - steel nut - wall plug VN Code
Description
Lt mm
do mm
h1 mm
Lp mm
Øp mm
Tfix mm
2440
TVNC 8/90
60
10
75
90
8
35
do h1 Lt Lp Øp Tfix
Examples of applications
= Hole diameter = Min. hole depth = Plug length = Hook length = Hook diameter = Fixture thickness
TVNC Substrate materials TVNC Ø10 Recommended values in daN 1 daN≃ 1 kg Concrete C20/25 Double brick UNI with plaster
60 50
393
cladding and pipe fixings
• always check load bearing capacity values in the table • respect the installation data • clean the hole before the installation
cladding and pipe fixings
Vorpa TVNO - TVNK Fixing set for free-standing toilets and bidets products group
SANITARY FIXING SET FOR TOILETS AND BIDETS WITH VERTICAL HOLES TVNO brass * TVNO stainless steel A2 The pronounced rim prevents contact between the screw and ceramics.
*
TVNK
do h1 Lt Lp Øp Øv Lv
SANITARY FIXING SET FOR TOILETS AND BIDETS WITH SIDE HOLES
A2 INOX 304
= Hole diameter = Min. hole depth = Plug length = Hook length = Hook diameter = Screw diameter = Screw length
installation sequence TVNO
cladding and pipe fixings
TVNK
Clean the hole before the installation
product code and technical data TVNO brass
*
TVNO stainless steel A2
TVNK
Code
Description
Lt mm
do mm
h1 mm
Lp mm
Øp mm
Code
Description
Lt mm
do mm
h1 mm
Lv mm
Øv mm
247 2247
TVNO 10/80 TVNO 10/80 INOX A2
50 50
10 10
75 75
80 80
6 6
2248
TVNK 10/50
50
10
75
60
7
Set content 4 plugs 10x50 - 4 screws 6x80 - 4 white sleeves - 4 nuts
Set content 2 plugs 10x50 - 2 hexagonal screws 7x65 - 2 nylon angles L - 2 washer Ø8 - 2 cover caps Ø18 - 2 nylon sleeves Ø15 - 2 screws Ø4,5x45
Examples of applications
394
7
Drill bits
drill bits
Vorpa GOLDCRAFT Universal drill bit
concrete
solid brick
natural stone
metals
wood
glass block
PVC
backed clay
porcellain
products group Suitable for • concrete • solid brick • natural stone • metal • wood • glass block • PVC • backed clay • porcellain
GOLDCRAFT
SET GOLDCRAFT
Drive
Execution 130°
product code and technical data Characteristics • universal drill bit with special cutting edge geometry • thanks to diamond-ground carbide tips GOLDCRAFT drill bit is suitable for almost all materials • special cutting edge geometry (see diagram) • the asymmetric spiral shape enable an optimum removal of drilling dust • high-temperature brazing at about 1.120 °C • special cutting helix with micro surface hardness • extremely wear resistant
Suggestion for use • regrinding of the carbide tip becomes necessary during prolonged use • higher wear of carbide tip when drilling in abrasive materials • only use sharp drill bits for drilling in porcellain, ceramics, glass block
P1 long series mm 150 - 200 Code
Description
5001 5002 5003 5004 5005 5006 5007 5008 5009 5010 5011
GOLDCRAFT GOLDCRAFT GOLDCRAFT GOLDCRAFT GOLDCRAFT GOLDCRAFT GOLDCRAFT GOLDCRAFT GOLDCRAFT GOLDCRAFT GOLDCRAFT
drill bits
/mm
Ø mm
Shank diameter mm
Code
Description
40 40 50 50 60 60 60 80 80 80 90
2,8 3,8 4,5 4,5 5,5 5,5 6,5 7,5 8 9 10
5021 5022 5023 5024 5025 5026
GOLDCRAFT P1 5 X 150 GOLDCRAFT P1 6 X 150 GOLDCRAFT P1 6,5 X 150 GOLDCRAFT P1 8 X 200 GOLDCRAFT P1 10 X 200 GOLDCRAFT P1 12 X 200
3 X 70 4 X 75 5 X 85 5,5 X 85 6 X 100 6,5 X 100 7 X 100 8 X 120 9 X 120 10 X 120 12 X 150
1.500
soft wood
1.880
1.030
ceramics
1.580
800
1.120
640
steel, cast steel
1.700
510
hard wood
850
410
glass, crystal
*
masonry, marble, artificial stone, concrete granite, tiles, plastic materials, acrylic
Shank diameter mm
110 110 110 135 135 135
4,5 5,5 5,5 7,5 9 10
Code
Description
5030
Set Goldcraft
Set content
5 GOLDCRAFT drills short version Ø mm 4 - 5 - 6 - 8 - 10
16
2.350
Usable length mm
SET GOLDCRAFT®
Guide values for universal drill bits Goldcraft
D
4
Usable length mm
* 398
drill bits
Vorpa HARDTEC Drill bit for hardtest materials
concrete
natural stone
glass block backed clay
porcellain
products group Suitable for • concrete • natural stone • glass block • backed clay • porcellain
HARDTEC
Drive
Execution 120°
SET HARDTEC
Prüfgemeinschaft Mauerbohrer (PGM) Certified product
product code and technical data Characteristics • hard stone drill bit with special cutting edge geometry • asymmetric spiral shape • staight flute entry • milled flute • special carbide tip • diamond-ground carbide tip • high-temperature vacuum brazing at 1120°C • wear resistant carbide drill bit with long life time • high drilling speed • the drill bit can be resharpened with a diamond or silicon carbide grinding wheel • very long service life
Suggestion for use • regrinding of the carbide tip becomes necessary during prolonged use • higher wear of carbide tip when drilling in abrasive materials • only use sharp drill bits for drilling in porcelain, ceramics, glass block
SET HARDTEC Code
Description
8062 8063 8064 8065 8066
HARDTEC 4 X 75 HARDTEC 5 X 85 HARDTEC 6 X 100 HARDTEC 8 X 120 HARDTEC 10 X 120
Usable length mm
Shank diameter mm
Code
Description
40 50 60 75 75
4 5 6 8 10
8067
Set Hardtec drills
Set content
5 HARDTEC drills Ø mm. 4 - 5 - 6 - 8 -10
Examples of applications
drill bits
399
drill bits
Vorpa PMS Universal drill bit for masonry
concrete
natural stone
solid brick
products group Suitable for • concrete • natural stone • solid brick
PMS
Drive
Execution 130°
product code and technical data Characteristics • metal universal drill bit for masonry • good chip and dust removal • for hobbyist and professional use
Short series Code
Description
6001 6002 6003 6004 6005 6006 6007 6008 6009 6010 6011 6012 6013 6014 6015 6016 6017 6018 6019 6020
PM S PM S PM S PM S PM S PM S PM S PM S PM S PM S PM S PM S PM S PM S PM S PM S PM S PM S PM S PM S
P1 long series mm 150 - 200
3 X 60 4 X 75 4,5 X 85 5 X 85 5,5 X 85 6 X 100 6,5 X 100 7 X 100 8 X 120 8,5 X 120 9 X 120 10 X 120 11 X 150 12 X 150 13 X 150 14 X 150 15 X 150 16 X 150 18 X 160 20 X 160
Shank diameter mm
Code
Description
2,5 3,5 3,5 4 4 5 5 5,5 6 6 7 8 8 8 8 10 10 13 13 13
6032 6033 6034 6035 6036
PM SP1 PM SP1 PM SP1 PM SP1 PM SP1
drill bits
Examples of applications
400
Shank diameter mm
6 X 200 8 X 200 10 X 200 12 X 200 14 X 200
5 6 8 8 10
drill bits
Vorpa SDS TURBO 4 cutting edges drill bit for concrete - professional use
concrete
natural stone
solid brick
products group
SDS TURBO
Suitable for • concrete • natural stone • solid brick
Drive
Execution
product code and technical data Characteristics • x-Shape 4 cutting edges drill bit for perforated hammers, professional use • made of chrome-nickel-molybdenum steel, shot-peened and hardened • specially designed head geometry for better center drilling • conical spiral drill bit • high drilling speed thanks to the helix carrying forward the impact of the machine up to the drilling head • low hand-arm vibrations thanks to the helix concept reducing the vibration loads generated during drilling • high stiffness and longer service life • 2 larger-volume flutes granting ideal and fast drilling-dust removal • greater fracture resistance thanks to the rounded step transitions and the strengthened core • the geometry with 4 cutting edges protects the bit against damage when impacting on reinforced steel • head geometry characterized by 6 drill-levels. Different setting depths of major and side plates. Shearing force is shared on 2 levels and secure a long life • cylindrical drilling holes, also in reinforced concrete • drilling process will not be distracted
1) Higher drilling speed
• the symmetric X-shape achieves higher drilling speed, in comparison to standard 90° design • x-shape with big entry-flutes for optimized drill-dust removal
2) Higher strength
• precise spot-drilling due to the centering point • armor-resistant and easy drilling into reinforced concrete • the multi-angle drill bit tip achieves an ideal drilling result, with long service life at the same time
3) More clean
• 4 cutting edges concept provide an accurate and correct guidance of the drill bit. Optimum vibration behavior
4 times secured quality due to: • optimized hardening and brazing process at 1.120° • second “stress-free” hardening • shot-blased surface • straightening process for exact true-running accuracy
Description
7130 7131 7132 7133 7134 7135 7136 7137 7138 7139 7140 7141 7142 7143 7144 7145 7146 7147 7148 7149 7150 7151 7152 7153 7154
SDS TURBO SDS TURBO SDS TURBO SDS TURBO SDS TURBO SDS TURBO SDS TURBO SDS TURBO SDS TURBO SDS TURBO SDS TURBO SDS TURBO SDS TURBO SDS TURBO SDS TURBO SDS TURBO SDS TURBO SDS TURBO SDS TURBO SDS TURBO SDS TURBO SDS TURBO SDS TURBO SDS TURBO SDS TURBO
Usable length mm
5 x 110 5 x 160 5 x 210 6 x 110 6 x 160 6 x 210 6 x 260 8 x 110 8 x 160 8 x 210 8 x 260 10 x 160 10 x 210 10 x 260 10 x 310 10 x 460 12 x 160 12 x 210 12 x 260 12 x 310 12 x 450 14 x 160 14 x 210 14 x 260 14 x 450
50 100 150 50 100 150 200 50 100 150 200 100 150 200 250 400 100 150 200 250 400 100 150 200 400
drill bits
401
Code
drill bits
Vorpa SDS PLUS Drill bit for hardtest materials - professional use
concrete
natural stone
solid brick
products group Suitable for • concrete • natural stone • solid brick
SDS PLUS
Drive
Execution
product code and technical data Characteristics • made of chrome-nickel-molybdenum steel, shot-peened and intermediate level hardened • specially designed carbide plate with centring tip,multi-step helix • reduces vibration loads and torsion loads generated during drilling • no drilling dust, higher drilling speed • transports the impact energy of the hammer drilling machine in an optimal way • greater fracture resistance, larger cutting angle • 64% faster thanks to multi-step helix • the helix is protected by patents. The number of spiral steps and radiuses on the drill depends on the hole diameter
drill bits
4 – 5 mm 6 – 7 mm 8 – 9 mm 10 – 12 mm 13 – 14 mm 15 – 16 mm 17 – 26 mm Code
Description
2000 1997 1998 2001 2002 2175 2181 2727 2003 2004 2033 1282 2981 1933 2005 2006 2007 2008 2009 2046 2034 2041 2035 2010 2011 2012 2042
SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS
2 spiral steps 4 spiral steps 6 spiral steps 8 spiral steps 6 spiral steps 8 spiral steps 10 spiral steps
4 X 110 4 X 160 4 X 180 5 X 110 5 X 160 5 X 260 5 X 310 5 X 410 6 X 110 6 X 160 6 X 210 6 X 260 6 X 360 6 X 460 7 X 110 7 X 160 8 X 110 8 X 160 8 X 210 8 X 310 8 X 400 8 X 460 9 X 160 9 X 210 10 X 110 10 X 160 10 X 210
Suggestion for use • for a working length of 400mm and more, pre-drilling must be carried out to a depth of at least 150mm with a drill bit of the same diameter • for a working length of 950mm and more, pre-drilling must be carried out to a depth of at least 400mm with a short drill bit of the same diameter • the warranty does not apply to extra-long drill bits of 1.000mm and more.
6 radiuses 10 radiuses 14 radiuses 18 radiuses 14 radiuses 18 radiuses 22 radiuses Usable length mm
Code
Description
50 100 120 50 100 200 260 350 50 100 150 200 300 400 50 100 50 100 150 250 350 410 100 150 50 100 150
2043 2013 2036 2014 2044 2015 2016 2031 2018 2019 2020 2021 2032 2022 2023 2048 2024 2039 2025 2040 2026 2037 2027 2038 2028 2049 2029 2030
SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS SDS -PLUS
402
Usable length mm
10 X 260 10 X 310 10 X 460 12 X 165 12 X 210 12 X 265 12 X 450 12 X 600 14 X 165 14 X 215 14 X 315 14 X 450 14 X 600 15 X 165 16 X 215 16 X 310 16 X 450 16 X 600 18 X 200 18 X 300 20 X 200 20 X 300 20 X 450 20 X 600 22 X 450 24 X 250 25 X 450 26 X 450
200 250 400 100 150 200 400 550 100 150 250 400 550 100 150 250 400 550 150 250 150 250 400 550 400 210 400 400
drill bits
Vorpa SDS PLUS V4 Drill bit for hardtest materials - professional use
concrete
natural stone
solid brick
products group
SDS PLUS V4
Suitable for • concrete • natural stone • solid brick
Drive
Execution
product code and technical data Characteristics • hammer drill bit 4 cutter, professional use • carbide plate with centring tip • straight flute entry • high-temperature brazing at about 1100°C • particulary suitable for fastenings • simple precise drilling of pilot holes
Description
2149 2051 2052 2053 2054 2055 2150 2151 2056 2057 2058 2059 2171 2155 2060 2061 2062 2063 2172 2064 2065 2066 2067 2159 2068
SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4
4 X 110 5 X 110 5 X 160 6 X 110 6 X 160 6 X 210 7 X 110 7 X 160 8 X 110 8 X 160 8 X 210 8 X 260 8 X 450 9 X 160 10 X 110 10 X 160 10 X 210 10 X 260 10 X 450 12 X 160 12 X 210 12 X 260 12 X 450 12 X 600 14 X 160
Usable length mm
Code
Description
50 50 100 50 100 150 50 100 50 100 150 200 400 100 50 100 150 200 400 100 150 200 400 550 100
2069 2070 2071 2162 2072 2073 2074 2075 2165 2076 2077 2166 2167 2078 2079 2080 2081 2169 2082 2168 2083 2170 2084
SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4 SDS-plus V4
403
Usable length mm
14 X 210 14 X 260 14 X 450 14 X 600 16 X 160 16 X 210 16 X 260 16 X 450 16 X 600 18 X 210 18 X 260 18 X 450 20 X 210 20 X 260 20 X 450 20 X 600 22 X 450 24 X 260 24 X 450 25 X 260 25 X 450 25 X 600 26 X 600
150 200 400 550 100 150 200 400 550 150 200 400 150 200 400 550 400 200 400 200 400 550 550
drill bits
Code
• considerably faster drilling progress • significantly longer life • high drilling speed • fast transport of drilling dust • high grade of stiffness and long service life • high resistance against breakage
drill bits
Vorpa SDS MAX Drill bit for hardtest materials - professional use
concrete
natural stone
solid brick
products group
SDS MAX
Suitable for • concrete • natural stone • solid brick
Drive
Execution
product code and technical data Characteristics • Ni-Cr-Mo steel drill bit, reinforced and tempered • head created for better centering, greater speed, precision of execution • the construction of the tip guarantees an accurate and correct guide significantly reducing the friction in the hole • the multi-cutting edge geometry protects the tip from impact with the rods in reinforced concrete
Code
Description
7060 7061 7062 7063 7064 7065 7066 7067 7068 7069 7070 7071
SDS-MAX SDS-MAX SDS-MAX SDS-MAX SDS-MAX SDS-MAX SDS-MAX SDS-MAX SDS-MAX SDS-MAX SDS-MAX SDS-MAX
12 X 340 12 X 540 14 X 340 14 X 540 16 X 340 16 X 540 18 X 340 18 X 540 20 X 320 20 X 520 22 X 320 22 X 520
• the discharge grooves with their considerable volume in the double helix ensure rapid chip removal • excellent vibration behavior • reduced friction and maximum energy transfer • centering guide and stability to torsional loads • precise holes, noise reduction, work protection Suggestion for use • for useful lengths greater than 400mm, first make a pre-hole up to a depth of at least 150mm with a short tip of the same diameter
Usable length mm
Code
Description
200 400 200 400 200 400 200 400 200 400 200 400
7072 7073 7074 7075 7076 7077 7078 7079 7080 7081 7082 7083
SDS-MAX SDS-MAX SDS-MAX SDS-MAX SDS-MAX SDS-MAX SDS-MAX SDS-MAX SDS-MAX SDS-MAX SDS-MAX SDS-MAX
drill bits
Examples of applications
404
Usable length mm
24 X 320 25 X 520 25 X 920 28 X 370 28 X 570 30 X 370 30 X 570 32 X 570 32 X 920 35 X 570 38 X 570 40 X 570
200 400 800 250 400 250 450 450 800 450 450 450
drill bits
Vorpa HSS DIN 338 Twist drill bit - up to 800N/m2 tensile strenght
metals
cast iron
brass
products group
HSS DIN 338
Suitable for • metal • cast iron • brass
Drive
Execution
product code and technical data Characteristics • high performance high-speed steel drill bit suitable for metal • high elasticity due to heat forming • robust core thickness and distinct hardness • special surface treatment reducing dust deposition • reduced danger of breakage thanks to the torsional strength • particularly suitable for professional use in metal, alloyed and unalloyed steel with a tensile strength up to 800 N/mm2, non-iron metal, cast iron and hard plastic
Code
Description
7001 7040 7002 7041 7003 7042 7004 7043 7005 7044 7006 7045 7007 7046 7008 7047
HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS
1 X 34 1,25 X 38 1,50 X 40 1,75 X 46 2 X 49 2,25 X 53 2,50 X 57 2,75 X 61 3 X 61 3,25 X 65 3,50 X 70 3,75 X 70 4 X 75 4,25 X 75 4,50 X 80 4,75 X 80
Examples of applications
Suggestion for use • in case of horizontal drilling and drilling depths 5 times bigger than diameter it is necessary to reduce the drilling speed of 20-40% • use special drilling oils in case of extremely hard alloy and heat resistant materials • use normal freezing mixtures for standard steel or low adhesiveness materials • dry-drilling in case of short chips, brass and cast iron • lift the drill bit for time to time in order that the oil can penetrate into the material • sharpen the cutting edges regularly • do not use drill bits with rotopercussion
Usable length mm
Code
Description
Usable length mm
12 16 18 23 24 27 30 33 33 36 39 39 43 43 47 47
7009 7048 7010 7049 7011 7050 7012 7051 7013 7014 7015 7016 7017 7018 7019 7020 7021 7022 7023 7024 7025
HSS 5 X 86 HSS 5,25 X 86 HSS 5,50 X 93 HSS 5,75 X 93 HSS 6 X 93 HSS 6,25 X 101 HSS 6,50 X 101 HSS 6,75 X 109 HSS 7 X 109 HSS 7,50 X 109 HSS 8 X 117 HSS 8,50 X 117 HSS 9 X 125 HSS 9,50 X 125 HSS 10 X 133 HSS 10,50 X 133 HSS 11 X 142 HSS 11,50 X 142 HSS 12 X 151 HS 12,50 X 151 HSS 13 X 151
52 52 57 57 57 63 63 69 69 69 75 75 81 81 87 87 94 94 101 101 101
405
M
D
3 4 5 6 8 10 12
2,4 - 2,5 3,2 - 3,3 4,0 - 4,2 4,8 - 5,0 6,4 - 6,8 7,9 - 8,5 9,6 - 10,2
drill bits
Guidelines for the execution of pre-drills to thread according to thread type
drill bits
Vorpa HSS CO 5% DIN 338 5% cobal twist drill bit - above 800N/m2 tensile strenght
A2 - A4 stainless steel
special alloys
alloyed steel
products group
HSS CO 5%
Suitable for • stainless steel A2 • stainless steel A4 • special alloysi • alloyed steel
Drive
Execution
product code and technical data Characteristics • cross-ground finish to DIN 1412 C (5% cobalt from Ø3,0mm). 135° conical section • direct drilling without prior centering or drilling of a pilot hole • safe pilot hole drilling, even in slanting surfaces, in pipes and/or welds • the feeding power is reduced by up to 50% • even chip removal and reduction of chip friction • extremely true running and precise round holes • the drill bit facilitates an increase in drilling progress by up to 45% • no jamming of the main cutting edge and no slipping of the drill bit for through-holes • high fracture strength and long life • reduced friction due to external diameter tapering in the shank direction • fast drilling progress through chemical thermal method of hardening and accurate cross-ground finish • due to the alloying addition of 5% Co these drill bits are well-suited for workpieces with a tensile strength of more than 800N/mm2. • extra high temperature strength to cope with suboptimal supply of coolant • up to 20% higher durability than identically constructed HSS drill bits used under the same operating conditions
Suggestion for use • use special drilling oils in case of extremely hard alloy and heat resistant materials • use normal freezing mixtures for standard steel or low adhesiveness materials • dry-drilling in case of short chips, brass and cast iron • lift the drill bit for time to time in order that the oil can penetrate into the material • sharpen the cutting edges regularly • do not use drill bits with rotopercussion
drill bits
Examples of applications
406
Code
Description
7100 7101 7102 7103 7104 7105 7106 7107 7108 7109 7110 7111 7112 7113 7114 7115 7116 7117 7118 7119 7120 7121 7122 7123 7124 7125 7126
HSS Co 5% 1x34 HSS Co 5% 1,5x40 HSS Co 5% 2x40 HSS Co 5% 2,5x57 HSS Co 5% 3x61 HSS Co 5% 3,2x65 HSS Co 5% 3,5x70 HSS Co 5% 4x75 HSS Co 5% 4,2x75 HSS Co 5% 4,5x80 HSS Co 5% 5x86 HSS Co 5% 5,5x93 HSS Co 5% 6x93 HSS Co 5% 6,5x101 HSS Co 5% 7x109 HSS Co 5% 7,5x109 HSS Co 5% 8x117 HSS Co 5% 8,5x117 HSS Co 5% 9x125 HSS Co 5% 9,5x125 HSS Co 5% 10x133 HSS Co 5% 0,5x133 HSS Co 5% 11x142 HSS Co 5% 11,5x142 HSS Co 5% 12x151 HSS Co 5% 12,5x151 HSS Co 5% 13x151
Usable length mm
Shank diameter mm
12 18 24 30 33 36 39 43 43 47 52 57 57 63 69 69 75 75 81 81 87 87 94 94 101 101 101
1,0 1,5 2,0 2,5 3,0 3,2 3,5 4 4,2 4,5 5 5,5 6 6,5 7 7,5 8 8,5 9 9,5 10 10,5 11 11,5 12 12,5 13
drill bits
Vorpa HSS TITANIUM DIN 338 Titanium coated twist drill bit - up to 900N/m2 tensile strenght
alloyed steel
A2 - A4 stainless steel
special alloys
cast iron
products group
HSS TITANIUM
Suitable for • stainless steel A2 • stainless steel A4 • special alloys • alloyed steel • cast iron
Drive
Execution
135°
product code and technical data Characteristics • ground tip coated with titanium. 135° conical section • direct drilling without prior centering or drilling of a pilot hole • safe pilot hole drilling, even in slanting surfaces, in pipes and/or welds • even chip removal and reduction of chip friction • extremely true running and precise round holes • no jamming of the main cutting edge and no slipping of the drill bit for through-holes • high fracture strength and long life • reduced friction due to external diameter tapering in the shank direction • due to the titanium coating addition, these drill bits are well-suited for workpieces with a tensile strength up to 900N/mm2-hardness 64-65HRC • extra high temperature strength to cope with suboptimal supply of coolant
Suggestion for use • to be used with lubricant and coolant emulsion • use special drilling oils in case of extremely hard alloy and heat resistant materials • use normal freezing mixtures for standard steel or low adhesiveness materials • dry-drilling in case of short chips, brass and cast iron • lift the drill bit for time to time in order that the oil can penetrate into the material • sharpen the cutting edges regularly • do not use drill bits with rotopercussion
Examples of applications
Description
8100 8101 8102 8103 8104 8105 8106 8107 8108 8109 8110 8111 8112 8113 8114 8115 8116 8117 8118 8119 8120 8121 8122 8123 8124 8125
HSS TITANIUM HSS TITANIUM HSS TITANIUM HSS TITANIUM HSS TITANIUM HSS TITANIUM HSS TITANIUM HSS TITANIUM HSS TITANIUM HSS TITANIUM HSS TITANIUM HSS TITANIUM HSS TITANIUM HSS TITANIUM HSS TITANIUM HSS TITANIUM HSS TITANIUM HSS TITANIUM HSS TITANIUM HSS TITANIUM HSS TITANIUM HSS TITANIUM HSS TITANIUM HSS TITANIUM HSS TITANIUM HSS TITANIUM
1x34 1,5x40 2x49 2,25x53 3x61 3,2x65 3,5x70 4x75 4,25x75 4,5x80 5x86 5,5x93 6x93 6,5x101 7x109 7,5x109 8x117 8,5x117 9,5x125 10x133 10,5x133 11x142 11,5x142 12x151 12,5x151 13x151
Usable length mm
Shank diameter mm
12 18 24 27 33 36 39 43 43 47 52 57 57 63 69 69 75 75 81 87 87 94 94 101 101 101
1,0 1,5 2,0 2,25 3,0 3,2 3,5 4 4,25 4,5 5 5,5 6 6,5 7 7,5 8 8,5 9,5 10 10,5 11 11,5 12 12,5 13
drill bits
407
Code
8
DIY line
PERSONALIZE YOUR SHOP
self service, merchandising
DIY products require a good looking environment that can make a positive impression on the customers. It is very important to lay down an interior by using the right displays and the best layout. Vorpa is here to offer the solution suitable for different needs. Moreover you can rely on a well-known brand, professional and high quality products and wide range satisfying any DIY fixing requirement.
410
displayers and merchandising
PERSONALIZE YOUR SHOP
self service, merchandising
411
Making fixing the incredible fun
By the Vorpa fixings presented in the self-service packaging everithing is possible! Every little housework will become easier and faster, each snobs creative hobby can be satisfied, any renovation will turn into a masterpiece. And all by utmost convenience and simplicity. To provide this Vorpa carried out the Instant Shop and Handy Blister projects, the ideal solutions to create a corned dedicated to the self-service sale.Fixings and fasteners are shown by attractive packaging and eyecatching display structures and supported by impact communication images to combine design with minimum space and maximum visibility.Try the service and Vorpa know-how, always flexible to the needs of the customers.
e z i l a n o s r e P ! p o h s r u o y Handy Blister self-service DIY line
Instant Shop self-service DIY line
About us Who we are
How to reach us
Vorpa is a company specialized in the design and production of fixing systems that achieved a significant position in the Italian and European market, thanks to precise orientations focused on two priority objectives: to provide an excellent level of manufacturing quality and
RICCIONE
strengthen all initiatives that provide value-added with the service to building and hardware distributors.
TRIESTE PADOVA
MILANO
VENEZIA TORINO GENOVA
BOLOGNA RICCIONE FIRENZE REP. SAN MARINO
Contacts na
og
ol
B
www.vorpa.com
A
ut
RIMINI SUD Casello - Exit
Rimini
os
tr
ad
RICCIONE Casello - Exit
a
RICCIONE
A
CATTOLICA Casello - Exit
14
Cattolica
M
ot
or
w
on
nc
A
ay
ANCONA
a
www.vorpa.com
Srl
Contact: Via San Leo, 5 - 47838 - Riccione - Italy Tel. +39 0541 607111 - Fax +39 0541 699015 vorpa@vorpa.com - www.vorpa.com