www.vorpa.com
2018
General Catalogue
General Catalogue 2018
products index
from page 11
1
from page 89
2
from page 173
3
from page 259
4
CHEMICAL ANCHORS
MECHANICAL HEAVY DUTY ANCHORS
FRAME AND GENERAL FIXINGS
SCAFFOLDING ANCHORS
products index
from page 280
5
from page 295
6
from page 329
7
from page 342
8
FIXINGS FOR INSULATION
CLADDING AND PIPE FIXINGS
MASONRY AND HSS DRILLS
SELF SERVICE
index by base material
Pag.
chemical anchors
in corso
In progress
CV.RE PRO 500
14
CV VSF PRO
23
CV ESF
31
CV.PSF
38
CV.PSF WINTER 410
45
CV.PSF TROPICAL 410
52
CV.PE
59
CV MULTISET PLUS 66 BITUMPHALTE 130 BITUM
69
EXTRUSION TOOLS FOR CHEMICAL ANCHORS
70
EASY PRESS 14,4V
71
ACCESSORIES
71
VF CE RESIN CAPSULES
83
FOAMPLUS UNIVERSAL
85
FOAMPLUS FOR ROOFING
86
FOAMFAST 750
87
self-expanding foams
= good
= good with limitations
Concrete
Natural stone
Solid brick
Perforated Perforated brick cement
Aerated poroton
Wood
index by base material
Pag.
mechanical heavy duty anchors
= good
VEX + SEISMIC
90
VE.1CE + SEISMIC
97
VE.7CE
101
VE.A
107
VE
113
VE.AL
115
VSA
116
VSP
120
VSX
124
CSB CE + SEISMIC
126
VA - VA CE
129
VA - VA F CE
130
TOP
132
TOP SA
139
AV
141
AVZ
145
VHM
147
AVZ G
149
VHS
151
VTS
157
VO
158
VHS AF
161
VHS AE
161
TOP AF
165
TOP AE
165
VH AE
167
ACCESSORIES
168
= good with limitations
Concrete
Natural stone
Solid brick
Perforated brick
Aerated poroton
Perforated cement
Aerated concrete
Wood
Boards and panels
index by base material
Pag.
Concrete
frame fixings / universal fixings THERMOISO PLUS
174
CLICK-UP
179
VK - TV Z
183
VN
189
SU P
192
VR
194
ZV
196
SV
201
VE O
206
HC - HR
207
HZ - HB
209
HU - HS
210
PC - NAF
213
VB - VBD
215
HZB
222
VPX - VP ZIP - VP RAME 224
= good
VPO - VPI - VPI CE
229
VP C CE
235
VP R6 - VP R8
242
VP A
248
FSS - FSC
250
VGA - VGN
252
CLAPS
254
VSL
255
= good with limitations
Wood
Natural stone
Solid brick
Perforated brick
Aerated Poroton
Perforated cement
Aerated Plasterboard Boards and concrete panels
index by base material
Pag.
scaffolding anchors TOP T
260
VN P
262
VSP-P
267
KIT TESTER
269
AC
272
AC R
277
CLAMP
279
VPL
281
PVC SPACERS
283
ISO CE
284
ISO CE TL
292
Concrete
Natural stone
Solid brick
anti - falling nets anchors - ENEL-TELECOM
fixing for insulation
= good
= good with limitations
Insulation panels
Perforated brick
Aerated poroton
Perforated cement
Aerated concrete
Wood
Boards and panels
index by base material
Pag.
cladding and pipe fixings IF - IFO
296
BRM - BRG
298
VRM - VR
299
CAV - CAV P
301
CDS 1/2� GAS
304
CFI
306
CFZ
307
CP
308
VCR
309
CT
310
KPO - KP
311
TC
313
FZ
316
SL
317
SFT
318
SPS
319
BANDING ROLL
320
U-BOLT
321
VNS
322
TV - TV NK
323
TVH
328
fissaggi idrotermosanitari - sanitary fixings
= good
Concrete
Natural stone
Solid brick
Perforated brick
Aerated poroton
Perforated cement
Aerated Plasterboard Boards and concrete panels
index by base material
Pag.
punte professionali - masonry and HSS drills
= good
GOLDCRAFT
330
HARDTEC
332
PMS
333
SDS TURBO
334
SDS PLUS
336
SDS PLUS V4
338
HSS DIN 388
339
HSS 5%
341
Concrete
Natural stone
Solid brick
Wood
Glass bricks cement
PVC
Metal
Stainless steel
Special alloys
Granite and Refractory Porcellain material Gres Klimker
Chemical anchors
chemical anchors Didactic table CV.RE PRO 500
CV.ESF
CV.VSF PRO
Extremely low temperature
Low temperature
385 ml
300 ml
165 ml
585 ml
345 ml
300 ml
1400 ml
400 ml
410 ml
Medium temperature
High temperature
Certifications
SEISMIC C1-C2
ETAG 01-05 Option 1
M8-M30/Rebar Ø 8 to 32mm For use in cracked or non-cracked concrete seismic class C1-C2
C1-C2
M8-M24/Rebar Ø 8 to 25mm Uncracked concrete
(in progress)
ETAG 001-05 Option 1
ETAG 01-01 TR 023
ETAG 029
Use category C, w/d - size:M10
Tested for LEED compliancy
ETAG 01-05 Option 7
M12-M16 Cracked concrete
M8-M16 Uncracked Concrete Pending
For use in cracked concrete seismic class C1-C2
Post-Installed Rebar Ø 8 to 25mm
ETAG 01-05
Bonded anchor for diamond coring for use in uncracked concrete
SEISMIC ETAG 001-05 Option 7
ETAG 01-01 TR 023
Post-Installed Rebar Ø 8 to 16mm
FIRE RATED
ETAG 029
Use category C, w/d size: M8-M10-M12
FIRE RATED
Tested for LEED compliancy
0974/W
Base materials
CLS
CLS FESSURATO
CLS ARMATO
CLS
CLS CLS LATERIZIO FESSURATO ARMATO FORATO
CLS
LATERIZIO PIENO
LATERIZIO FORATO
To be used with
Water in hole condition
Anche acqua di mare Sizes according to certifications
Anche acqua di mare
M8 - M30 Threaded bar
M12 - M16 Threaded bar
Ø8 - Ø32 Rebars
Ø8 - Ø25 Rebars
12
Anche acqua di mare
M10 Threaded bar
chemical anchors Didactic table CV.PSF
CV.PE
CV.PSF SPECIAL
Extremely low temperature
Low temperature
165 ml
410 ml
300 ml Medium temperature
300 ml
410 ml
410 ml High temperature
410 ml
ETAG 029
ETAG 01-05 Option 7
Use category C, w/d - size:M10
M8-M16 Uncracked Concrete
Tested for LEED compliancy
* Winter type
ETAG 01-05 Option 7
M8-M16 Uncracked Concrete
0978/W
Certifications
*
Certificato su legno da
Tested for LEED compliancy
0978/W 0974/W
ETAG 029
Use category C, w/d size: M8-M10-M12
Tested for LEED compliancy
0978/W
Base materials
CLS
LATERIZIO LEGNO LATERIZIO PIENO FORATO
CLS
LATERIZIO PIENO
LATERIZIO FORATO
LATERIZIO PIENO
LATERIZIO FORATO To be used with
Water in hole condition
Sizes according to certifications
M8 - M16 Threaded bar
M8 - M16 Threaded bar
M8 - M16 Threaded bar
13
chemical anchors
Vorpa CV.RE PRO 500 - Fixing in seismic C1 - C2 - Annex E 3:1 high performance pure epoxy A+ rating resin with ETA option 1 for cracked and non-cracked concrete TR023 post installed rebar
Cracked and non-cracked concrete
products group Suitable • Cracked and non-cracked concrete • Fixing in seismic C1-C2
CV.RE PRO 500 - 1400ml
To fix • structural fixings • heavy duty metal structures • heavy structural works • construction joints • scaffolding links • wall ties, starter bars, studs, bolts & large screws • electric installations plumbing
AN
IEQc4.1
D
F
LI
TE TE S
CY
Styrene Free
OR
L EE D C O
M
P
CV.RE PRO 500 - 585ml CV.RE PRO 500 - 385ml
FIRE RATED
ETAG 001-01 Option 1 M8-M30/Rebar Ø8-32mm for use in cracked and uncracked concrete
ETAG 01-05 bonded anchor for diamond coring for use in uncracked concrete
ETAG 01-01 TR 023 post installed rebar Ø8 to 25mm
For more details please see ETA.
Examples of applications
14
FIXING IN SEISMIC C1-C2
chemical anchors
Vorpa CV.RE PRO 500 - Fixing in seismic C1 - C2 - Annex E 3:1 high performance pure epoxy A+ rating resin with ETA option 1 for cracked and non-cracked concrete TR023 post installed rebar
Cracked and non-cracked concrete
product information Characteristics • 3:1, high performance, rapid curing, two part chemical anchoring system based on Pure Epoxy Acrylate resin. Applied in one single action this resin will produce a high performance, strong fixing with exceptionally high chemical resistance.
Benefits • Zero shrinkage enables large diameter installations • Close edge distance and small spacing • Independently tested and approved - anchor life 50 years • For diamond drilled holes, with rebar, and in areas of high chemical exposure eg. Seasalt and swimming pools. • Long working times • Low odour A+ rating VOC content • ETA Option 1 ETAG 001 for cracked concrete with studs and rebar TR029 • ETA Option 1 ETAG 01-01 for rebar TR023 • ETA approved in flooded holes, wet and dry concrete • WRC Water Approval • F120 Fire Test report
Benefits • C2 seismic performance • High bond strength with High load resistance • Used with all grades of threaded rod and rebar in accordance with TR029 • Ideal for deep embedment installations • Used in dry and wet concrete • Used in flooded holes • Used for overhead applications • Ideal for diamond drilled holes • Ideal for elevate temperatures - temperature ranges I, II AND III/dielectric fixings • Ideal for rebar installation under TR029 and EN1992-1-1:2004 EC2
Suggestion for use • Performance based on clean holes. HAMMER DRILLED – blown and then brushed with a stiff metal brush and blown again.
installation sequence Solid brick
technical data Minimum Curing Time Concrete Temperature
Gel-working Time
≥ 5°C ≥ 15°C ≥ 25°C ≥ 35°C ≥ 40°C
120 min 60 min 25 min 16 min 10 min
Temperature Ranges Minimum curing time Minimum curing time in dry concrete in wet concrete
50 h 20 h 8h 4h 2,5 h
x2 x2 x2 x2 x2
- Full cure 24 hours - All specifications based on supplied mixer Physical Properties
N/mm2 (MPa)
Test Method
Tensile Strength Compressive Strength Flexural Strength Flexural Modulus E Modulus Density Shrinkage VOC Content
29,36 120 39 3706 3420 1,42 kg/dm3 < 0,4% A+
ASTM D638 EN 196 PARTE 1 EN 196 PARTE 1 ASTM D790 EN 196 PARTE 1 -
Temperature Range
Concrete Service Temperature
Range I Range II Range III
-40°C to +40°C -40°C to +60°C -40°C to +72°C
Maximum Long Term Maximum Short Term Concrete Temp Concrete Temp
+24°C +43°C +43°C
+40°C +60°C +72°C
Service temperature range: Range of ambient temperatures after installation and during the lifetime of the anchor. Short term temperature: Temperature within the service temperature range which vary over short intervals, e.g. day/night cycles and freeze/than cycles. Long term temperature: Temperature, within the service temperature range, which will be approximately constant over significant periods of time.
Code
1171 1173 1169
15
Description
CV. RE PRO 500 CV. RE PRO 500 CV. RE PRO 500
Content ml
Gun to be used
385 585 1400
side by side 3:1 side by side 3:1 side by side 3:1
chemical anchors
Vorpa CV.RE PRO 500 - Fixing in seismic C1 - C2 - Annex E 3:1 high performance pure epoxy A+ rating resin with ETA option 1 for cracked and non-cracked concrete TR023 post installed rebar
Cracked and non-cracked concrete
technical data Typical characteristic and design resistance performance with 5.8 grade studding and associated installation data Characteristic Resistance (kN) Ă&#x2DC; mm
8
10
12
16
20
24
27
30
33
36
Trazione (Nrk) 19,00 19,00 19,00 28,27 30,20 30,20 39,58 43,80 43,80 56,30 81,60 81,60 73,51 127,40 127,40 90,48 183,60 183,60 119,97 238,00 238,00 135,72 292,00 292,00 148,25 342,12 360,00 174,74 396,07 425,00
Taglio (Vrk)
9,00
15,00
21,00
39,00
61,00
88,00
115,00
142,50
173,50
212,50
Design Resistance (kN)
Recommended Load (kN)
Characteristic distances (mm)
Min Edge and Spacing
Nominal Embedment
Trazione (Nrd)
Trazione (Nrec)
Bordo Spacing Bordo (Ccr,N) (Scr,N) (Ccr,V)
(mm) (Cmin Smin)
(mm)
12,70 12,70 12,70 15,71 20,10 20,10 21,99 29,20 29,20 31,28 54,40 54,40 35,01 84,90 84,90 43,08 122,40 122,40 53,32 159,10 159,10 64,63 194,50 194,50 70,60 162,91 240,60 83,21 188,60 283,33
Taglio (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
92,00
114,00
138,80
170,00
9,07 9,07 9,07 11,22 14,36 14,36 15,71 20,86 20,86 22,34 38,86 38,86 25,00 60,64 60,64 30,77 87,43 87,43 38,08 109,52 109,52 46,16 133,33 133,33 50,43 116,36 165,20 59,43 134,72 202,38
Taglio (Vrec)
5,14
80
160
80
40
8,57
100
200
90
50
12,00
120
240
110
60
22,29
160
320
125
80
34,86
200
400
180
100
50,29
240
480
220
120
65,71
270
540
240
135
81,43
300
600
280
150
99,14
330
660
310
165
121,43
360
720
330
180
60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 110 240 540 120 280 600 130 300 660 150 340 720
Hole Hole Max diameter diameter Torque concrete fixture (mm)
(mm)
(Nm)
10
9
10
12
12
20
14
14
40
18
18
80
24
22
120
28
26
160
32
30
180
35
32
200
37
36
250
40
38
300
= Steel failure All data is based on correct installation - see instructions No influence of edge and spacing Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d
16
chemical anchors
Vorpa CV.RE PRO 500 - Fixing in seismic C1 - C2 - Annex E 3:1 high performance pure epoxy A+ rating resin with ETA option 1 for cracked and non-cracked concrete TR023 post installed rebar
Cracked and non-cracked concrete
technical data Design resistance with various stud strenghts and rebar 5.8 grade steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30 33 36
10 12 14 18 24 28 32 35 38 40
depth mm
hef failure
embedment depth 60 70 80 90 100 110 12.6 12.7 15.7 18.3 20.1 22.0 25.1 28.3 29.2 31.4 35.3 39.2 43.1 33.2 37.3 41.5 45.6 43.0 47.3 53.2
60
70
80
90
100
110
120
130
140
160
200
240
280
320
47.1 49.8 51.6 58.0 64.5
51.0 53.9 55.9 62.9 69.8 71.4
120
130
54.4 58.1 60.2 67.7 75.2 76.9 77.6 140
66.4 68.8 77.4 86.0 87.9 88.7 160
82.9 86.0 96.7 107.5 109.9 110.8 200
84.9 103.2 116.1 128.9 131.9 133.0 240
120.4 135.4 150.4 153.9 155.2 280
122.4 154.7 171.9 175.9 177.4 320
400
480
540
600
660
720
159.1 194.5 219.8 240.6 221.7 266.0 283.2 400 480 540 600
660
720
Fd,s design load
(mm)
(kN)
61 77 93 139 205 285 329 362 438 511
12.7 20.1 29.2 54.4 84.9 122.4 159.1 194.5 240.6 283.2
hef
Fd,s
8.8 grade steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30 33 36
10 12 14 18 24 28 32 35 38 40
depth mm
failure
embedment depth 60 70 80 12.6 14.7 16.8 15.7 18.3 20.9 22.0 25.1 31.4 33.2
60
70
80
90 18.8 23.6 28.3 35.3 37.3
90
100 19.5 26.2 31.4 39.2 41.5 43.0
100
110
120
28.8 34.5 43.1 45.6 47.3 53.2
30.9 37.7 47.1 49.8 51.6 58.0 64.5
110
120
130
140
160
200
240
280
320
400
480
540
40.8 51.0 53.9 55.9 62.9 69.8 71.4
44.0 54.9 58.1 60.2 67.7 75.2 76.9 77.6 140
45.0 62.7 66.4 68.8 77.4 86.0 87.9 88.7 160
78.4 82.9 86.0 96.7 107.5 109.9 110.8 200
83.7 99.5 103.2 116.1 128.9 131.9 133.0 240
116.1 120.4 135.4 150.4 153.9 155.2 280
130.7 137.5 154.7 171.9 175.9 177.4 320
171.9 193.4 214.9 219.8 221.7 400
188.3 232.1 257.9 263.8 266.0 480
244.8 290.1 296.7 299.3 540
130
600
660
720
299.2 329.7 362.7 370.1 332.5 365.8 399.1 600 660 720
design load
(mm)
(kN)
93 118 143 214 315 438 506 557 674 786
19.5 30.9 45.0 83.7 130.7 188.3 244.8 299.2 370.1 435.7
hef
Fd,s
A-70 stainless steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30 33 36
10 12 14 18 24 28 32 35 38 40
depth mm
failure
embedment depth 60 70 80 12.6 13.7 15.7 18.3 20.9 22.0 25.1 31.4 33.2
60
70
80
90
100
110
120
21.7 28.3 31.6 35.3 39.2 43.1 47.1 37.3 41.5 45.6 49.8 43.0 47.3 51.6 53.2 58.0 64.5
90
100
110
120
130
140
160
200
51.0 53.9 55.9 62.9 69.8 71.4
54.9 58.1 60.2 67.7 75.2 76.9 77.6 140
58.8 66.4 68.8 77.4 86.0 87.9 88.7 160
82.9 86.0 80.2 98.1 109.9 110.8 200
130
*1 = tensile strenght 500N/mm2
17
240
280
320
400
480
540
600
660
720
660
1 1 1 1 720
91.7 103.2 120.4 132.1
121 133.0 143 240 280
320
400
480
540
600
design load
(mm)
(kN)
65 83 100 150 221 307 166 183 221 258
13.7 21.7 31.6 58.8 91.7 132.1 80.2 98.1 121.3 142.8
chemical anchors
Vorpa CV.RE PRO 500 - Fixing in seismic C1 - C2 - Annex E 3:1 high performance pure epoxy A+ rating resin with ETA option 1 for cracked and non-cracked concrete TR023 post installed rebar
Cracked and non-cracked concrete
technical data High bond reinforcing bars Fyk = 800 N/mm2 Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 25 28 32 36 40
10 12 15 20 25 30 35 40 44 50
hef 60 70 80 11.7 13.7 15.6 14.7 17.1 19.6 19.1 21.8 26.8 28.7
depth mm
60
70
80
90 17.6 22.0 24.5 30.2 32.3
90
100 19.6 24.4 27.2 33.5 35.9 41.1
100
110 21.5 26.9 30.0 36.9 39.5 45.3 50.7
110
120 23.5 29.3 32.7 40.2 43.1 49.4 55.3
120
130 25.2 31.8 35.4 43.6 46.7 53.5 59.9 68.5
130
140 34.2 38.1 46.9 50.3 57.6 64.5 73.7 79.2 140
160 39.1 43.6 53.6 57.5 65.8 73.7 84.3 90.5 95.8 160
200
240
39.3 54.5 67.0 71.9 82.3 92.2 105.3 113.1 119.7 200
56.6 80.4 86.2 98.7 110.6 126.4 135.7 143.6 240
Fd,s
failure
embedment depth 280
93.8 100.5 115.2 129.0 147.5 158.4 167.6 280
320
400
100.6 114.9 131.7 147.5 168.5 181.0 191.5 320
143.6 164.6 184.3 210.7 226.0 239.4 400
500
205.7 230.4 263.3 282.8 299.2 500
560
258.1 294.9 316.7 335.1 560
640
720
800
337.1 362.0 407.2 383.0 430.9 478.8 640 720 800
design load
(mm)
(kN)
129 161 208 300 438 549 668 763 902 1050
25.2 39.3 56.6 100.6 157.1 226.0 308.0 402.1 510.0 628.3
Characteristic and Design Load resistances based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non Cracked Concrete Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
27
30
33
36
Tension (Nrk) 22,62 30,16 60,32 28,27 42,41 94,25 39,58 62,20 135,72 56,30 87,96 225,19 73,51 138,86 326,73 90,48 190,00 434,29 111,97 244,29 549,65 132,72 316,76 678,59 148,25 342,12 752,66 174,74 396,07 838,73
Shear (Vrk)
9,00
15,00
21,00
39,00
61,00
88,00
115,00
142,50
173,50
212,50
Cracked Concrete
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
12,57 16,76 33,51 15,71 23,56 52,36 21,99 34,56 75,40 31,28 48,87 125,11 35,01 66,12 155,58 43,08 90,48 206,81 53,32 116,33 261,74 64,63 150,80 323,14 70,60 162,91 358,41 83,21 188,60 399,40
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
92,00
114,00
138,80
170,00
8,98 11,97 23,94 11,22 16,83 37,40 15,71 24,68 53,86 22,34 34,91 89,36 25,00 47,23 111,13 30,77 64,63 147,72 38,08 83,09 186,96 46,16 107,71 230,81 50,43 116,37 256,01 59,43 134,72 285,28
Shear (Vrec)
Characteristic Resistance (kN) Tension (Nrk)
Shear (Vrk)
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
Shear (Vrd)
Shear (Vrec)
5,14 Not applicable
Not applicable
Not applicable
8,57 19,79 31,10 67,86 26,14 42,22 104,55 33,93 63,90 150,80 41,47 85,50 199,05 51,32 107,49 251,92 62,20 133,00 311,02 67,39 140,27 342,12 76,34 154,47 366,44
12,00
22,29
34,86
50,29
65,71
81,43
99,14
121,43
21,00
39,00
61,00
88,00
115,00
142,50
173,50
212,50
All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C
18
11,00 17,28 37,70 14,52 23,46 58,08 16,16 30,41 71,81 19,75 40,71 94,79 24,44 51,18 119,96 29,62 63,33 148,10 32,09 66,80 162,91 36,35 73,56 174,49
16,80
31,20
48,80
70,40
92,00
114,00
138,80
170,00
7,85 12,34 26,93 10,37 16,75 41,49 11,54 21,72 51,29 14,11 29,10 67,70 17,46 36,56 85,69 21,16 45,24 105,79 22,92 47,71 116,37 25,97 52,54 124,64
12,00
22,29
34,86
50,29
65,71
81,43
99,14
121,43
Nominal Embedment (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 110 240 540 120 280 600 130 300 660 150 340 720
chemical anchors
Vorpa CV.RE PRO 500 - Fixing in seismic C1 - C2 - Annex E 3:1 high performance pure epoxy A+ rating resin with ETA option 1 for cracked and non-cracked concrete TR023 post installed rebar
Cracked and non-cracked concrete
technical data Bond Strength Factors Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.98
1.00
1.02
1.04
1.06
1.08
1.09
1.10
Influence of environmental conditions in non cracked concrete
Temp I 40°C/24°C
Temp II 60°C/43°C
Temp II 72°C/43°C
M8
M10
M12
M16
M20
M24
M27
M30
M33
M36
Dry and Wet
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
Flooded
1.00
0.94
0.87
0.79
0.71
0.65
0.65
0.60
0.57
0.55
Dry and Wet
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
Flooded
0.65
0.63
0.61
0.59
0.57
0.54
0.50
0.49
0.46
0.44
Dry and Wet
0.57
0.56
0.54
0.53
0.52
0.51
0.50
0.49
0.47
0.46
Flooded
0.57
0.54
0.52
0.51
0.50
0.49
0.46
0.45
0.43
0.42
Influence of environmental conditions in cracked concrete
Temp I 40°C/24°C
Temp II 60°C/43°C
Temp II 72°C/43°C
M8
M10
M12
M16
M20
M24
M27
M30
M33
M36
Dry and Wet
n/a
n/a
0.50
0.48
0.46
0.45
0.44
0.42
0.41
0.39
Flooded
n/a
n/a
0.50
0.42
0.38
0.38
0.35
0.30
0.27
0.24
Dry and Wet
n/a
n/a
0.32
0.31
0.30
0.29
0.29
0.28
0.27
0.26
Flooded
n/a
n/a
0.32
0.29
0.28
0.27
0.27
0.25
0.24
0.23
Dry and Wet
n/a
n/a
0.27
0.27
0.26
0.25
0.24
0.23
0.23
0.22
Flooded
n/a
n/a
0.27
0.27
0.26
0.25
0.24
0.23
0.23
0.22
19
chemical anchors
Vorpa CV.RE PRO 500 - Fixing in seismic C1 - C2 - Annex E 3:1 high performance pure epoxy A+ rating resin with ETA option 1 for cracked and non-cracked concrete TR023 post installed rebar
Cracked and non-cracked concrete
technical data Characteristic and Design Load resistances for REBAR based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non Cracked Concrete Characteristic Resistance (kN) Ø mm
8
10
12
16
20
25
28
32
Tension (Nrk)
Shear (Vrk)
21,11 28,15 56,30 26,39 39,58 87,96 34,31 53,91 117,62 48,25 75,40 193,02 67,86 128,18 301,59 86,39 181,43 431,97 108,37 270,93 541,86 141,55 353,87 707,74
13,95
21,45
31,05
55,50
86,55
135,00
168,75
220,95
Cracked Concrete
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
Shear (Vrd)
11,73 15,64 31,30 14,66 21,99 48,87 19,06 29,95 65,35 26,81 41,89 107,23 32,31 61,04 143,62 41,14 86,39 205,70 51,61 129,02 258,03 67,40 168,51 337,02
9,30
14,30
20,70
37,00
57,70
90,00
112,50
147,30
8,38 11,17 22,34 10,47 15,71 34,91 13,61 21,39 46,68 19,15 29,92 76,60 23,08 43,60 102,58 29,39 61,71 146,93 36,86 92,15 184,31 48,15 120,36 240,73
Characteristic Resistance (kN)
Shear (Vrec)
Tension (Nrk)
Shear (Vrk)
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
Shear (Vrd)
Nominal Embedment
Shear (Vrec)
(mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 500 112 280 560 128 320 640
6,64 Not applicable
Not applicable
Not applicable
10,21 19,79 31,10 67,86 26,14 40,84 104,55 33,93 64,09 150,80 43,20 90,71 215,99 54,19 135,47 270,93 70,77 176,93 353,87
14,79
26,43
41,21
64,29
80,36
105,21
31,05
55,50
86,55
135,00
168,75
220,95
11,00 17,28 37,70 14,52 22,69 58,08 16,16 30,52 71,81 20,57 43,20 102,85 25,80 64,51 129,02 33,70 84,25 168,51
20,70
37,00
57,70
90,00
112,50
147,30
7,85 12,34 26,93 10,37 16,21 41,49 11,54 21,80 51,29 14,69 30,86 73,46 18,43 46,08 92,15 24,07 60,18 120,36
14,79
26,43
41,21
64,29
80,36
105,21
All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C
Bond Strength Factors - REBAR Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
C55/67
C60/75
C70/85
0.98
1.00
1.02
1.04
1.06
1.08
1.09
1.10
1.10
1.12
1.13
Influence of environmental conditions in non cracked concrete
Temp I 40°C/24°C
Temp II 60°C/43°C
Temp II 72°C/43°C
Ø8
Ø10
Ø12
Ø16
Ø20
Ø25
Ø28
Ø32
Dry and Wet
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
Flooded
1.00
0.94
0.90
0.85
0.80
0.71
0.65
0.63
Dry and Wet
0.67
0.65
0.63
0.62
0.61
0.60
0.60
0.59
Flooded
0.65
0.64
0.61
0.59
0.58
0.56
0.55
0.47
Dry and Wet
0.60
0.58
0.57
0.56
0.56
0.55
0.54
0.53
Flooded
0.58
0.56
0.53
0.50
0.47
0.45
0.43
0.41
20
C80/96 C90/105 1.14
1.15
chemical anchors
Vorpa CV.RE PRO 500 - Fixing in seismic C1 - C2 - Annex E 3:1 high performance pure epoxy A+ rating resin with ETA option 1 for cracked and non-cracked concrete TR023 post installed rebar technical data Influence of environmental conditions in cracked concrete
Temp I 40°C/24°C
Temp II 60°C/43°C
Temp II 72°C/43°C
Ø8
Ø10
Ø12
Ø16
Ø20
Ø25
Ø28
Ø32
Dry and Wet
n/a
n/a
0.55
0.47
0.44
0.43
0.42
0.41
Flooded
n/a
n/a
0.55
0.42
0.40
0.38
0.36
0.35
Dry and Wet
n/a
n/a
0.30
0.28
0.26
0.24
0.23
0.23
Flooded
n/a
n/a
0.30
0.27
0.25
0.23
0.22
0.22
Dry and Wet
n/a
n/a
0.30
0.26
0.25
0.24
0.23
0.22
Flooded
n/a
n/a
0.30
0.26
0.24
0.23
0.23
0.22
Post installed rebar connections Minimum anchorage length 1) and lap splice length for C20/25 and maximum installation length (l max) Rebar
lb,min (mm)
lo,min (mm)
lmax,min (mm)
Ø ds
fy,k (N/mm2)
8mm
500
113
200
1000
10mm
500
142
200
1000
12mm
500
170
200
1200
14mm
500
198
210
1400
16mm
500
227
240
1600
20mm
500
284
300
2000
22mm
500
312
330
2000
24mm
500
340
360
2000
25mm
500
354
375
2000
N/mm2 = MPa
1) According to EN 1992-1-1:2004 lb,min (8.6) e lo,min (8.11) for good bond conditions and as = 1,0 with maximum yeld stress for rebar B500 e yM - 1,15
Design values of the ultimate bond resistance fbd 1) in N/mm2 for all drilling methods for good conditions Rebar Ø
Concrete Class
Ø ds
C12/15
C16/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/60
C50/60
8mm to 25mm
1.6
2
2.3
2.7
3
3.4
3.7
4
4.3
1) Tabulated values for fbd are valid for good bond condition according to EN 1992-1-1:2004. For all other bond conditions multiply the values for fbd by 0.7.
21
Cracked and non-cracked concrete
chemical anchors
Vorpa CV.RE PRO 500 - Fixing in seismic C1 - C2 - Annex E 3:1 high performance pure epoxy A+ rating resin with ETA option 1 for cracked and non-cracked concrete TR023 post installed rebar
Cracked and non-cracked concrete
technical data Effect of anchor spacing - Tension Anchor spacing (mm) (mm) 40 50 60 70 80 90 100 120 150 160 175 200 225 240 250 275 280 300 320 350 400 440 480 540 600 660 720 800
Effect of edge distance - Tension Edge distance (mm) 40 50 60 70 80 90 100 110 120 140 160 180 200 220 240 270 300 330 360 400
Stud/Rebar diameter 8 0,64 0,67 0,70 0,73 0,76 0,79 0,82 0,87 0,96 1,00
10
0,63 0,65 0,67 0,69 0,72 0,74 0,79 0,86 0,88 0,92 1,00
12
0,63 0,64 0,66 0,68 0,70 0,74 0,80 0,82 0,85 0,90 0,95 1,00
16
0,63 0,64 0,65 0,68 0,73 0,74 0,76 0,80 0,84 0,86 0,87 0,91 0,92 0,95 1,00
20
0,63 0,65 0,68 0,70 0,71 0,74 0,77 0,79 0,80 0,83 0,84 0,86 0,88 0,92 1,00
24
0,63 0,65 0,66 0,67 0,69 0,72 0,73 0,74 0,76 0,77 0,79 0,81 0,83 0,88 0,92 1,00
27
0,63 0,64 0,65 0,66 0,69 0,71 0,72 0,73 0,75 0,76 0,78 0,80 0,82 0,87 0,91 0,94 1,00
30
0,63 0,63 0,64 0,66 0,68 0,69 0,70 0,72 0,73 0,74 0,76 0,78 0,82 0,85 0,88 0,93 1,00
33
0,63 0,63 0,65 0,67 0,68 0,69 0,71 0,71 0,73 0,74 0,77 0,80 0,83 0,86 0,91 0,96 1,00
36
0,63 0,63 0,65 0,67 0,68 0,68 0,70 0,70 0,72 0,73 0,75 0,78 0,81 0,84 0,88 0,92 0,96 1,00
40
0,63 0,63 0,65 0,66 0,67 0,68 0,69 0,69 0,71 0,72 0,73 0,76 0,79 0,81 0,84 0,88 0,91 0,95 1,00
Stud/Rebar diameter 8 0,64 0,73 0,82 0,90 1,00
10 0,63 0,70 0,77 0,84 0,91 1,00
12
0,63 0,68 0,74 0,80 0,86 0,92 1,00
16
0,63 0,67 0,71 0,76 0,80 0,89 1,00
20
0,63 0,66 0,70 0,77 0,84 0,91 1,00
24
0,64 0,67 0,72 0,78 0,84 0,89 1,00
27
30
0,63 0,70 0,75 0,81 0,86 0,92 1,00
0,63 0,65 0,70 0,76 0,81 0,86 0,94 1,00
27
30
0,35 0,51 0,63 0,75 0,88 1,00
0,30 0,35 0,46 0,57 0,68 0,78 1,00
33
36
0,63 0,66 0,71 0,75 0,80 0,87 0,94 1,00
0,67 0,71 0,74 0,78 0,82 0,87 0,93 0,98 1,00
33
36
0,32 0,37 0,46 0,56 0,65 0,84 1,00
0,33 0,43 0,50 0,56 0,63 0,77 1,00 1,00
40
0,68 0,71 0,75 0,78 0,83 0,88 0,93 0,98 1,00
Effect of edge distance - Shear Edge distance (mm) 40 50 60 70 80 90 100 110 125 140 160 180 200 220 240 280 310 330 400
22
Stud/Rebar diameter 8 0,25 0,44 0,63 0,81 1,00
10 0,30 0,48 0,65 0,83 1,00
12
0,30 0,44 0,58 0,72 0,86 1,00
16
20
24
0,40 0,53 0,67 0,35 0,80 0,44 1,00 0,58 0,35 0,72 0,46 0,91 0,62 1,00 0,77 0,92 1,00
40
0,32 0,53 0,59 0,72 0,82 0,89 1,00
chemical anchors
Vorpa CV.VSF CE PRO
Vinylester styrene free chemical anchor with European Technical Approval for non-cracked concrete cracked concrete, post installed rebar
Cracked and non-cracked concrete
Natural stone
Solid brick
Marble
Wood
products group
CV.VSF PRO 300 CE
Suitable • Cracked and non-cracked concrete • Natural stone • Solid brick • Marble • Wood
To fix • structural fixings • heavy duty metal structures • heavy structural works • construction joints • scaffolding links • wall ties, starter bars, studs, bolts & large screws • electric installations plumbing
ETAG 01-01 TR023 Post installed Rebar Ø 8 to Ø 16 mm
ETAG 001-05 Option 7 M8-M24 / Rebars Ø 8 to 25 mm For non-cracked concrete
ETAG 001-05 Option 1 M12-M16 / Threaded bars For cracked concrete
FIXING IN SEISMIC * C1-C2
CV.VSF PRO 345 CE
* C1-C2 SEISMIC ETA PENDING CV.VSF PRO 400 CE FIRE RATED
23
Styrene Free
Tested for LEED compliancy
chemical anchors
Vorpa CV.VSF CE PRO
Vinylester styrene free chemical anchor with European Technical Approval for non-cracked concrete cracked concrete, post installed rebar
Cracked and non-cracked concrete
Natural stone
Solid brick
Marble
Wood
product information Characteristics • High performance, rapid curing, two part chemical anchoring system based on a high reactivity Vinylester Styrene Free resin. Applied in one single action this resin will produce a strong, chemical resistant fixing. Features • High bond strength with High load resistance • Used in non-cracked and cracked concrete • Fast gelling and curing • Used in dry and wet concrete • Used in critical or overhead applications • Used in corrosive environments • Used for rebar installations under TR029 • Used for post-installed rebar under TRO23 • Low shrinkage enables large diameter installations • Close edge distance and small spacing • High chemical resistance • Use with potable water WRC water Approval BS 6920 • Fire approved F180 • Eta Option 7 ETAG for uncracked concrete with studs and M8-M24 rebar TR029 Ø8-Ø25 • ETA Option 1 ETAG 001 for cracked concrete with studs M12-M16 • ETA option ETAG 01-01 for post-installed rebar connections TR023 Ø8 to Ø16 mm
Benefit • High performances. Non-flammable and non-hazardous • Styrene free. Very low odor, ideal as well for indoor usage A+ rating • Available in different formats • Cartridge can be used up to the end of the validity date by replacing the static mixer or releasing cartridge with the sealing cap Suggestion for use • Performance based on clean holes. HAMMER DRILLED – blown and then brushed with a stiff metal brush and blown again.
installation sequence Solid brick
Code
1008 1120 1160
Description
CV. VSF PRO 345 CE CV. VSF PRO 400 CE CV. VSF PRO 300 CE
Content
Gun to be used
345 400 300
side by side coaxial silicone
24
chemical anchors
Vorpa CV.VSF CE PRO
Vinylester styrene free chemical anchor with European Technical Approval for non-cracked concrete cracked concrete, post installed rebar
Cracked and non-cracked concrete
Natural stone
Solid brick
Marble
Wood
technical data Minimum Curing Time
Temperature Ranges
Concrete Temperature
Gel-working Time
-10°C * -5°C * 5°C 15°C 25°C 35°C
50 min 40 min 20 min 9 min 5 min 3 min
Minimum curing time Minimum curing time in dry concrete in wet concrete
240 min 180 min 90 min 60 min 30 min 20 min
x2 x2 x2 x2 x2 x2
Compressive Strength Flexural Strength Flexural Modulus Tensile Strength E Modulus VOC Content
Concrete Service Temperature
Range I Range II
-40°C to +40°C -40°C to +80°C
Maximum Long Term Maximum Short Term Concrete Temp Concrete Temp
+40°C +80°C
+24°C +50°C
Service temperature range: Range of ambient temperatures after installation and during the lifetime of the anchor. Short term temperature: Temperature within the service temperature range which vary over short intervals, e.g. day/night cycles and freeze/than cycles. Long term temperature: Temperature, within the service temperature range, which will be approximately constant over significant periods of time.
* Resin temperature must be at least 20°C - Full cure 24 hours - All specifications based on supplied mixer Physical Properties
Temperature Range
N/mm2 (MPa)
Test Method
73,0 25,0 3850,0 14,6 8029,7 A+
EN ISO 604 / ASTM 695 EN ISO 178 / ASTM 790 EN ISO 178 / ASTM 790 EN ISO 527 / ASTM 638 EN ISO 527 / ASTM 638 -
Loads, Edge and Spacings based on Characteristic bond strengths - Showing steel failure with 5.8 grade studding and associated installation data Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
27
30
33
36
Tension (Nrk) 19,00 19,00 19,00 22,62 30,20 30,20 29,82 43,80 43,80 43,43 67,86 81,60 55,42 104,68 127,40 63,33 133,00 183,60 70,91 154,72 238,00 78,04 182,09 292,00 88,95 205,27 360,00 108,57 246,10 425,00
Shear (Vrk)
9,00
15,00
21,00
39,00
61,00
88,00
115,00
142,50
173,50
212,50
Design Resistance (kN)
Recommended Load (kN)
Characteristic distances (mm)
Tension (Nrd)
Tension (Nrec)
Shear (Vrec)
Edge (Ncr,N)
Spacing (Scr,N)
5,14
80
8,57
12,70 12,70 12,70 15,08 20,10 20,10 19,88 29,20 29,20 28,95 45,24 54,40 36,95 69,79 84,90 42,22 88,67 122,40 47,27 103,15 159,10 52,02 121,39 194,50 59,30 136,85 240,60 72,38 164,07 283,33
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
92,00
114,00
138,80
170,00
9,07 9,07 9,07 10,77 14,36 14,36 14,20 20,86 20,86 20,68 32,31 38,86 26,39 49,85 60,64 30,16 63,33 87,43 33,77 73,68 113,64 37,16 86,71 138,93 42,36 97,75 171,86 51,70 117,19 202,38
Min Edge and Spacing
Nominal Embedment
Edge (Ccr,V)
(mm) (Cmin Smin)
(mm)
160
80
40
100
200
90
50
12,00
120
240
110
60
22,29
160
320
125
80
34,86
200
400
180
100
50,29
230
460
220
120
65,71
270
540
240
135
81,43
280
560
280
150
121,43
310
620
310
165
121,43
330
660
330
180
All data is based on correct installation - see instructions Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d
25
60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 110 240 540 120 280 600 130 300 660 150 340 720
Hole Hole Max diameter diameter Torque concrete fixture (mm)
(mm)
(Nm)
10
9
10
12
12
20
14
14
40
18
18
80
24
22
120
28
26
160
32
30
180
35
32
200
37
36
250
40
38
300
= steel failure
chemical anchors
Vorpa CV.VSF CE PRO
Vinylester styrene free chemical anchor with European Technical Approval for non-cracked concrete cracked concrete, post installed rebar
Cracked and non-cracked concrete
Natural stone
Solid brick
Marble
Wood
hef
Fd,s
technical data Design resistance of resin with various stud strenghts and rebar 5.8 grade steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30 33 36
10 12 14 18 24 28 32 35 38 40
depth mm
failure
60 70 80 90 12.7 15.1 17.6 20.1 19.9 22.7 25.6 29.0 32.6 32.8 36.9
60
70
80
90
100
110
28.4 36.2 41.1 42.2
29,2 39.8 45.2 46.5 47.3
100
110
120
130
140
160
200
240
280
320
400
43.4 49.3 50.7 51.6 52.0
47.1 53.4 54.9 55.9 56.4 59.3
120
130
50.7 57.5 59.1 60.2 60.7 63.9 67.6 140
54.4 65.7 67.6 68.8 69.4 73.0 77.2 160
82.1 84.5 86.0 86.7 91.2 96.5 200
84.9 101.3 103.2 104.1 109.5 115.8 240
118.2 120.3 121.4 127.7 135.1 280
122.4 137.5 138.8 146.0 154.4 320
159.1 173.4 182.5 193.0 400
480
540
600
660
720
194.5 219.0 240.6 231.6 260.6 283.2 480 540 600 660
720
design load
(mm)
(kN)
59 80 103 150 207 290 370 449 527 587
12.7 20.1 29.2 54.4 84.9 122.4 159.1 194.5 240.6 283.2
hef
Fd,s
8.8 grade steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30 33 36
10 12 14 18 24 28 32 35 38 40
depth mm
failure
60 70 80 12.9 15.0 17.2 15.1 17.6 20.1 19.9 22.7 29.0 32.8
60
70
80
90 19.3 22.6 25.6 32.6 36.9
90
100 19.5 25.1 28.4 36.2 41.1 42.2
100
110
120
130
27.6 31.2 39.8 45.2 46.5 47.3
30.2 34.1 43.4 49.3 50.7 51.6 52.0
30.9 36.9 47.1 53.4 54.9 55.9 56.4 59.3
120
130
110
140
160
200
240
280
320
400
480
540
39.8 50.7 57.5 59.1 60.2 60.7 63.9 67.6 140
45.0 57.9 65.7 67.6 68.8 69.4 73.0 77.2 160
72.4 82.1 84.5 86.0 86.7 91.2 96.5 200
83.7 98.5 101.3 103.2 104.1 109.5 115.8 240
114.9 118.2 120.3 121.4 127.7 135.1 280
130.7 135.1 137.5 138.8 146.0 154.4 320
168.9 171.9 173.4 182.5 193.0 400
188.3 206.3 208.1 219.0 231.6 480
232.1 234.1 246.4 260.6 540
600
660
720
260.2 273.7 301.1 289.5 318.5 347.4 600 660 720
design load
(mm)
(kN)
91 123 158 231 318 446 570 690 811 903
19.5 30.9 45.0 83.7 130.7 188.3 244.8 299.2 370.1 435.7
hef
Fd,s
10.9 grade steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30 33 36
10 12 14 18 24 28 32 35 38 40
depth mm
failure
60 70 80 12.9 15.0 17.2 15.1 17.6 20.1 19.9 22.7 29.0 32.8
60
70
80
90 19.3 22.6 25.6 32.6 36.9
90
100 21.4 25.1 28.4 36.2 41.1 42.2
110 23.6 27.6 31.2 39.8 45.2 46.5 47.3
120 25.7 30.2 34.1 43.4 49.3 50.7 51.6 52.0
130 27.2 32.7 36.9 47.1 53.4 54.9 55.9 56.4 59.3
100
110
120
130
140
160
200
240
280
320
400
480
35.2 39.8 50.7 57.5 59.1 60.2 60.7 63.9 67.6 140
40.2 45.4 57.9 65.7 67.6 68.8 69.4 73.0 77.2 160
43.1 56.8 72.4 82.1 84.5 86.0 86.7 91.2 96.5 200
62.6 86.9 98.5 101.3 103.2 104.1 109.5 115.8 240
101.3 114.9 118.2 120.3 121.4 127.7 135.1 280
115.8 131.4 135.1 137.5 138.8 146.0 154.4 320
116.6 164.2 168.9 171.9 173.4 182.5 193.0 400
202.7 206.3 208.1 219.0 231.6 480
26
540
600
660
720
(mm)
127 171 220 322 443 621 793 232.1 961 234.1 260.2 1130 246.4 273.7 301.1 260.6 289.5 318.5 347.4 1258 540 600 660 720
design load
(kN)
27.2 43.1 62.6 116.6 182.0 262.2 341.0 416.7 515.5 606.9
chemical anchors
Vorpa CV.VSF CE PRO
Vinylester styrene free chemical anchor with European Technical Approval for non-cracked concrete cracked concrete, post installed rebar
Cracked and non-cracked concrete
Natural stone
Solid brick
Marble
Wood
hef
Fd,s
technical data
A4-70 stainless steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30 33 36
10 12 14 18 24 28 32 35 38 40
depth mm
failure
60 70 80 12.9 13.7 15.1 17.6 20.1 19.9 22.7 29.0 32.8
60
70
80
90
100
110
120
21.7 25.6 28.4 31.2 31.6 32.6 36.2 39.8 43.4 36.9 41.1 45.2 49.3 42.2 46.5 50.7 47.3 51.6 52.0
90
100
110
120
130
140
160
200
47.1 53.4 54.9 55.9 56.4 59.3
50.7 57.5 59.1 60.2 60.7 63.9 67.6 140
57.9 65.7 67.6 68.8 69.4 73.0 77.2 160
58.8 82.1 84.5 80.2 86.7 91.2 96.5 200
130
240
280
320
400
480
540
600
660
720
400
480
540
600
660
720
91.7 101.3 118.2 132.1 98.1 109.5 121 115.8 135.1 143 240 280 320
design load
(mm)
(kN)
64 86 111 162 223 313 187 226 266 296
13.7 21.7 31.6 58.8 91.7 132.1 80.2 98.1 121.3 142.8
hef
Fd,s
High bond reinforcing bars Fyk = 500 N/mm2 Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 25 28 32 36 40
10 12 15 20 25 30 35 40 44 50
depth mm
failure
60 70 80 8.7 10.2 11.7 10.4 12.1 13.8 13.7 15.7 19.3 21.0
60
70
80
90 13.1 15.6 17.6 21.7 23.6
90
100 14.6 17.3 19.6 24.1 26.2 28.3
110 16.0 19.0 21.6 26.5 28.9 31.1 33.4
120 17.5 20.7 23.5 29.0 31.5 33.9 36.4
130 19.0 22.5 25.5 31.4 34.1 36.8 39.5 43.1
140 20.4 24.2 27.4 33.8 36.7 39.6 42.5 46.5 52.3
100
110
120
130
140
160 21.9 27.6 31.4 38.6 42.0 45.2 48.6 53.1 59.7 66.4 160
200
240
280
320
400
500
34.1 39.2 48.3 52.5 56.6 60.7 66.4 74.7 82.9 200
47.1 57.9 63.0 67.9 72.8 79.6 89.6 99.5 240
49.2 67.6 73.5 79.2 85.0 92.9 104.5 116.1 280
77.2 84.0 90.5 97.1 106.2 119.4 132.7 320
105.0 113.1 121.4 132.7 149.3 165.9 400
141.4 151.8 165.9 186.6 207.4 500
27
560
640
720
800
(mm)
150 198 251 362 521 695 882 170.0 1054 185.8 212.3 1188 209.0 238.9 268.8 232.3 265.4 298.6 331.8 1317 560 640 720 800
design load
(kN)
21.9 34.1 49.2 87.4 136.6 196.5 267.8 349.7 443.5 546.3
chemical anchors
Vorpa CV.VSF CE PRO
Vinylester styrene free chemical anchor with European Technical Approval for non-cracked concrete cracked concrete, post installed rebar
Cracked and non-cracked concrete
Natural stone
Solid brick
Marble
Wood
technical data Characteristic and Design Load resistances based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non Cracked Concrete Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
27
30
33
36
Tension (Nrk)
Shear (Vrk)
19,30 25,74 51,47 22,62 33,93 75,40 29,82 46,86 102,24 43,43 67,86 173,72 55,42 104,68 246,30 63,33 133,00 304,01 70,91 154,72 348,11 78,04 182,09 390,19 88,95 205,27 451,60 108,57 246,10 521,15
9,00
15,00
21,00
39,00
61,00
88,00
115,00
142,50
173,50
212,50
Cracked Concrete
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
12,87 17,16 34,31 15,08 22,62 50,27 19,88 31,24 68,16 28,95 45,24 115,81 36,95 69,79 164,20 42,22 88,67 202,67 47,27 103,15 232,08 52,02 121,39 260,12 59,30 136,85 301,07 72,38 164,07 347,44
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
92,00
114,00
138,80
170,00
9,19 12,26 24,51 10,77 16,16 35,90 14,20 22,31 48,69 20,68 32,31 82,72 26,39 49,85 117,29 30,16 63,33 144,76 33,77 73,68 165,77 37,16 86,71 185,80 42,36 97,75 215,05 51,70 117,19 248,17
Characteristic Resistance (kN)
Shear (Vrec)
Tension (Nrk)
Shear (Vrk)
Not applicable
5,14
10,40 15,60 34,68 13,12 20,62 44,98 17,37 27,14 69,50 21,06 39,78 93,60
8,57
12,00
22,29
34,86
15,00
21,00
39,00
61,00
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
Shear (Vrd)
Not applicable 6,94 10,40 23,12 8,75 13,75 29,98 11,58 18,10 46,33 14,04 26,52 62,40
12,00
16,80
31,20
48,80
Nominal Embedment
Shear (Vrec)
Not applicable 4,96 7,43 16,52 6,24 9,82 21,42 8,27 12,93 33,10 10,00 18,94 44,59
8,57
12,00
22,29
34,86
50,29 Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
65,71
81,43
99,14
121,43
All data is based on correct installation - see instructions. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C
Bond Strength Factors
Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) non cracked fc= cracked fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.94 0.96
1.00 1.00
1.06 1.03
1.12 1.05
1.17 1.06
1.23 1.07
1.26 1.08
1.30 1.09
Influence of environmental conditions in non cracked concrete
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
M8
M10
M12
M16
M20
M24
M27
M30
M33
M36
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.90
0.88
0.87
0.86
0.85
0.84
0.83
0.82
0.81
0.80
Influence of environmental conditions in cracked concrete
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
M8
M10
M12
M16
M20
M24
M27
M30
n/a
0.46
0.44
0.40
0.38
n/a
n/a
n/a
n/a
0.45
0.43
0.40
0.38
n/a
n/a
n/a
28
(mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 110 240 540 120 280 600 130 300 660 150 340 720
chemical anchors
Vorpa CV.VSF CE PRO
Vinylester styrene free chemical anchor with European Technical Approval for non-cracked concrete cracked concrete, post installed rebar
Cracked and non-cracked concrete
Natural stone
Solid brick
Marble
Wood
technical data Characteristic and Design Load resistances for REBAR based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non Cracked Concrete Characteristic Resistance (kN) Ø mm
8
10
12
14
16
18
20
22
25
28
32
Tension (Nrk)
Shear (Vrk)
15,68 20,91 41,82 18,66 27,99 62,20 24,70 38,82 84,69 31,67 45,52 110,84 34,74 54,29 138,97 37,55 70,40 168,97 36,76 69,43 163,36 44,92 85,36 197,67 51,05 107,21 255,26 61,08 152,71 305,41 77,21 193,02 386,04
13,95
21,45
31,05
42,45
55,50
69,66
86,55
104,01
135,00
168,75
220,95
Cracked Concrete
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
Shear (Vrd)
8,71 11,62 23,23 10,37 15,55 34,56 13,72 21,56 47,05 17,59 25,29 61,58 19,30 30,16 77,21 20,86 39,11 93,87 20,42 38,57 90,76 24,96 47,42 109,82 28,36 59,56 141,81 33,93 84,84 169,67 42,89 107,23 214,47
9,30
14,30
20,70
28,30
37,00
46,44
57,70
69,34
90,00
112,50
147,30
6,22 8,30 16,60 7,41 11,11 24,68 9,80 15,40 33,61 12,57 18,06 43,98 13,79 21,54 55,15 14,90 27,94 67,05 14,59 27,55 64,83 17,83 33,87 78,44 20,26 42,54 101,29 24,24 60,60 121,20 30,64 76,60 153,19
Characteristic Resistance (kN)
Shear (Vrec)
Tension (Nrk)
Shear (Vrk)
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
Shear (Vrd)
Nominal Embedment
Shear (Vrec)
6,64 Not applicable
Not applicable
Not applicable
10,21 10,56 16,59 36,19 13,72 19,73 48,03 15,28 23,88 61,12 16,51 30,96 74,31 19,79 37,39 87,96 24,19 45,96 106,44 27,49 57,73 137,45
14,79
20,21
26,43
33,17
41,21
49,53
64,29
31,05
42,45
55,50
69,66
86,55
104,00
135,00
5,86 9,22 20,11 7,62 10,96 26,68 8,49 13,26 33,96 9,17 17,20 41,28 11,00 20,77 48,87 13,44 25,53 59,13 15,27 32,07 76,36
20,70
28,10
37,00
46,44
57,70
69,34
90,00
4,19 6,58 14,36 5,45 7,83 19,06 6,06 9,47 24,26 6,55 12,29 29,49 7,85 14,84 34,91 9,60 18,24 42,24 10,91 22,91 54,54
14,79
20,07
26,43
33,17
41,21
49,53
64,29
80,36 Not applicable
Not applicable
Not applicable
105,21
All data is based on correct installation - see instructions. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C
Bond Strength Factors - REBAR Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) non cracked fc= cracked fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.94 0.96
1.00 1.00
1.06 1.03
1.12 1.05
1.17 1.06
1.23 1.07
1.26 1.08
1.30 1.09
Influence of environmental conditions in non cracked concrete
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
Ø8
Ø 10
Ø 12
Ø 14
Ø 16
Ø 18
Ø 20
Ø 22
Ø 25
Ø 28
Ø 32
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.53
1.00
1.00
1.00
0.90
0.90
0.88
0.88
0.88
0.86
0.86
0.56
0.86
0.84
0.84
29
(mm) 60 80 160 60 90 200 70 110 240 80 115 280 80 125 320 80 150 360 90 170 400 100 190 440 100 210 500 112 280 560 128 320 640
chemical anchors
Vorpa CV.VSF CE PRO
Vinylester styrene free chemical anchor with European Technical Approval for non-cracked concrete cracked concrete, post installed rebar
Cracked and non-cracked concrete
Natural stone
Solid brick
Marble
Wood
technical data Influence of environmental conditions in cracked concrete
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
Ø8
Ø 10
Ø 12
Ø 14
Ø 16
Ø 18
Ø 20
Ø 22
Ø 25
Ø 28
Ø 32
n/a
n/a
0.50
0.43
0.50
0.43
0.50
0.53
0.50
n/a
n/a
n/a
n/a
0.44
0.38
0.44
0.38
0.43
0.46
0.43
n/a
n/a
Effect of anchor spacing - Tension Anchor spacing (mm) 40 50 60 70 80 90 100 120 150 160 180 200 225 240 250 275 280 300 320 350 400 440 460 500 540 560 620 660 720
Effect of edge distance - Tension Edge distance (mm) 40 50 60 70 80 90 100 110 120 140 160 180 200 220 240 270 280 310 330 360
Stud/Rebar diameter 8 0,64 0,67 0,70 0,73 0,76 0,79 0,82 0,87 0,96 1,00
10 0,63 0,65 0,67 0,69 0,72 0,74 0,79 0,86 0,88 0,93 1,00
12
0,63 0,64 0,66 0,68 0,70 0,74 0,80 0,82 0,86 0,90 0,95 1,00
16
0,63 0,64 0,65 0,68 0,73 0,74 0,77 0,80 0,84 0,86 0,87 0,91 0,92 0,95 1,00
20
0,63 0,65 0,68 0,70 0,72 0,74 0,77 0,79 0,80 0,83 0,84 0,86 0,88 0,92 1,00
24
0,63 0,65 0,66 0,68 0,69 0,72 0,73 0,74 0,76 0,77 0,79 0,81 0,83 0,88 0,92 1,00
27
0,64 0,65 0,65 0,67 0,69 0,71 0,72 0,74 0,75 0,76 0,78 0,81 0,86 0,89 0,91 0,95 1,00
30
0,63 0,63 0,65 0,66 0,68 0,69 0,70 0,72 0,73 0,74 0,76 0,78 0,82 0,85 0,87 0,90 0,93 1,00
33
0,62 0,64 0,65 0,67 0,69 0,70 0,72 0,72 0,74 0,75 0,78 0,82 0,85 0,87 0,90 0,93 0,95 1,00
36
0,64 0,65 0,67 0,68 0,68 0,70 0,70 0,72 0,73 0,75 0,78 0,81 0,82 0,85 0,88 0,89 0,93 1,00
40
0,63 0,64 0,65 0,66 0,67 0,68 0,69 0,69 0,71 0,72 0,73 0,76 0,79 0,80 0,82 0,84 0,86 0,89 0,91 1,00
Stud/Rebar diameter 8 0,64 0,73 0,82 0,90 1,00
10 0,63 0,70 0,77 0,84 0,91 1,00
12
0,63 0,68 0,74 0,80 0,86 0,92 1,00
16
0,63 0,67 0,71 0,76 0,80 0,89 1,00
20
0,63 0,66 0,70 0,77 0,84 0,91 1,00
24
0,64 0,67 0,72 0,78 0,84 0,89 1,00
27
30
0,63 0,70 0,75 0,81 0,86 0,92 1,00
0,63 0,65 0,66 0,76 0,81 0,86 0,94 1,00
27
30
0,44 0,57 0,69 0,82 0,94 1,00
0,30 0,35 0,46 0,57 0,68 0,78 1,00
33
0,62 0,70 0,76 0,81 0,86 0,94 0,97 1,00
36
40
0,67 0,78 0,82 0,87 0,93 0,96 0,98 1,00
0,68 0,71 0,75 0,78 0,83 0,85 0,90 0,93 1,00
36
40
Effect of edge distance - Shear Edge distance (mm) 40 50 60 70 80 90 100 110 125 140 160 180 200 220 240 280 310 330 360
30
Stud/Rebar diameter 8 0,25 0,44 0,63 0,81 1,00
10 0,30 0,48 0,65 0,83 1,00
12
0,30 0,44 0,58 0,72 0,86 1,00
16
20
24
0,40 0,53 0,67 0,35 0,80 0,44 1,00 0,58 0,35 0,72 0,46 0,91 0,62 1,00 0,77 0,92 1,00
33
0,34 0,41 0,50 0,59 0,68 0,86 1,00
0,33 0,42 0,51 0,60 0,78 0,91 1,00
0,32 0,53 0,59 0,72 0,82 0,89 1,00
chemical anchors
Vorpa CV.ESF CE
Epoxy acrylate styrene free chemical anchor with European Technical Approval injection anchor for use in masonry - Approval Option 7 pending products group
Concrete
Natural stone
Wood
Solid brick
Suitable • concrete • natural stone • wood • solid brick • marble • hollow brick • solid brick • perforated cement
CV.ESF 825 CE
ETAG 029 For masonry & Hollow Walls Use category c, w/d Size M10 Steel elements according to Table 2 Annex 5 of ETA-11/0032
ETAG 001-05 option 7 M8-M16 non cracked concrete pending
CV.ESF 300 CE CV.ESF 410 CE
Tested for LEED compliancy
CV.ESF 165 CE
31
Styrene Free
Marble
Hollow brick
Perforated brick
Perforated cement
To fix • heavy duty metal structures • heavy duty structural works • construction joints • scaffolding links • wall ties, starter bars, studs, bolts & large screws
chemical anchors
Vorpa CV.ESF CE
Epoxy acrylate styrene free chemical anchor with European Technical Approval injection anchor for use in masonry - Approval Option 7 pending product information
Concrete
Characteristics • High performance, rapid curing, two part chemical anchoring system based on Epoxy Acrylate Styrene Free resin. Applied in one single action this resin will produce a cost effective, strong, chemical resistant fixing. Benefits • ETA approval for use in masonry M10 • ETA approval for use in non concrete opt.7 pending • Chemical corrosion resistant • Ideal to be used with reinforcing bars • Suitable for close edge applications, no tension on base material • Suitable for high load applications on concrete, natural stone and solid brick • High loading values at reduced embedment depths • Easy to be extruded granting quicker working times • High performances. Non-flammable and non-hazardous • Styrene free. Very low odor, ideal as well for indoor usage A+rating • Available in different formats
Natural stone
Wood
Hollow brick
1114 1002E 1110 1111
CV. ESF 825 CE CV. ESF 410 CE CV. ESF 300 CE CV. ESF 165 CE
Hollow brick
Perforated brick
Perforated cement
Suggestion for use • Performance based on clean holes. HAMMER DRILLED – blown and then brushed with a stiff metal brush and blown again.
Solid brick
Description
Marble
Characteristics • Cartridge can be used up to the end of the validity date by replacing the static mixer or releasing cartridge with the sealing cap • Fast celling and curing • Used in dry and wet concrete • Extremely versatile
installation sequence
Code
Solid brick
Content ml
Gun to be used
825 410 300 165
side by side coaxial silicone silicone
32
chemical anchors
Vorpa CV.ESF CE
Epoxy acrylate styrene free chemical anchor with European Technical Approval injection anchor for use in masonry - Approval Option 7 pending technical data
Concrete
Minimum Curing Time Gel-working Time
-10°C * -5°C * 5°C 15°C 25°C 35°C
40 min 40 min 15 min 8 min 5 min 3 min
Minimum curing time Minimum curing time in dry concrete in wet concrete
x2 x2 x2 x2 x2 x2
240 min 240 min 120 min 60 min 45 min 30 min
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
Temperature Range
Concrete Service Temperature
Range I Range II
-40°C to +40°C -40°C to +60°C
Maximum Long Term Maximum Short Term Concrete Temp Concrete Temp
+24°C +50°C
+40°C +80°C
Service temperature range: Range of ambient temperatures after installation and during the lifetime of the anchor. Short term temperature: Temperature within the service temperature range which vary over short intervals, e.g. day/night cycles and freeze/than cycles. Long term temperature: Temperature, within the service temperature range, which will be approximately constant over significant periods of time.
* Resin temperature must be at least 20°C - Full cure 24 hours - All specifications based on supplied mixer
Compressive Strength Flexural Strength Flexural Modulus Tensile Strength E Modulus VOC Content
Wood
Temperature Ranges
Concrete Temperature
Physical Properties
Natural stone
N/mm2 (MPa)
Test Method
45 15,4 3111,7 9,4 5488,5 A+
EN ISO 604 / ASTM 695 EN ISO 178 / ASTM 790 EN ISO 178 / ASTM 790 EN ISO 527 / ASTM 638 EN ISO 527 / ASTM 638 -
Loads, Edge and Spacings based on Characteristic bond strengths - Showing steel failure with 5.8 grade studding Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
30
Tension (Nrk) 17,79 19,00 19,00 20,81 30,20 30,20 27,45 43,13 43,80 39,97 62,46 81,60 50,89 96,13 127,40 58,28 122,39 183,60 71,82 167,57 292,00
Shear (Vrk)
9,00
15,00
21,00
39,00
61,00
88,00
142,50
Design Resistance (kN)
Recommended Load (kN)
Characteristic distances (mm)
Tension (Nrd)
Tension (Nrec)
Shear (Vrec)
Edge (Ncr,N)
Spacing (Scr,N)
5,14
80
8,57
9,88 12,70 12,70 11,56 20,10 20,10 15,25 23,96 29,20 22,21 34,70 54,40 28,27 53,41 84,90 32,38 68,00 122,40 39,90 93,10 194,50
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
114,00
7,06 9,07 9,07 8,26 14,36 14,36 10,89 17,11 20,86 15,86 24,78 38,86 20,20 38,15 60,64 23,13 48,57 87,43 28,50 66,50 138,93
Min Edge and Spacing
Nominal Embedment
Edge (Ccr,V)
(mm) (Cmin Smin)
(mm)
160
80
40
100
200
90
50
12,00
120
240
110
60
22,29
160
320
125
80
34,86
200
400
180
100
50,29
240
480
220
120
81,43
280
560
280
150
All data is based on correct installation - see instructions No influence of edge and spacing Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C
33
60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 110 280 600
Hole Hole Max diameter diameter Torque concrete fixture (mm)
(mm)
(Nm)
10
9
10
12
12
20
14
14
40
18
18
80
24
22
120
28
26
160
35
32
200
= Steel failure
chemical anchors
Vorpa CV.ESF CE
Epoxy acrylate styrene free chemical anchor with European Technical Approval injection anchor for use in masonry - Approval Option 7 pending technical data
Concrete
Natural stone
Design resistance of resin with various stud strenghts and rebar
Wood
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
= Steel failure
5.8 grade steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
hef failure
embedment depth 60 7.3 8.1
60
70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
90
100 12.1 13.5 15.5 19.3 22.4 22.6
110 12.7 14.9 17.0 21.2 24.7 24.9 26.1
100
110
120 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 20.1 24.7 30.9 35.9 36.2 38.0 37.7 160
200 29.2 38.6 44.9 45.2 47.5 47.1 200
240
46.3 53.8 54.3 57.0 56.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
54.4 71.8 72.4 76.0 75.4 320
400
480
540
600
660
84.9 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660
720
Fd,s design load
(mm)
(kN)
105 148 189 282 379 541 670 825
12.7 20.1 29.2 54.4 84.9 122.4 159.1 194.5
hef
Fd,s
720
8.8 grade steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
failure
embedment depth 60 7.3 8.1
60
70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
90
100 12.1 13.5 15.5 19.3 22.4 22.6
110 13.3 14.9 17.0 21.2 24.7 24.9 26.1
100
110
120 14.5 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 15.8 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 17.0 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 19.5 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160
200 27.1 30.9 38.6 44.9 45.2 47.5 47.1 200
240 37.1 46.3 53.8 54.3 57.0 56.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
61.8 71.8 72.4 76.0 75.4 320
400
480
540
600
660
89.7 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660
720
design load
(mm)
(kN)
161 228 291 434 582 832 1031 1270
19.5 30.9 45.0 83.7 130.7 188.3 244.8 299.2
hef
Fd,s
720
10.9 grade steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
failure
embedment depth 60 7.3 8.1
60
70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
90
100 12.1 13.5 15.5 19.3 22.4 22.6
110 13.3 14.9 17.0 21.2 24.7 24.9 26.1
100
110
120 14.5 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 15.8 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 17.0 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 19.4 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160
200 27.1 30.9 38.6 44.9 45.2 47.5 47.1 200
240 37.1 46.3 53.8 54.3 57.0 56.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
61.8 71.8 72.4 76.0 75.4 320
400
480
540
600
660
89.7 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660
720
design load
(mm)
(kN)
224 318 405 604 811 1159 1435 1768
27.2 43.1 62.6 116.6 182.0 262.2 341.0 416.7
hef
Fd,s
720
A4-70 grade steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
failure
embedment depth 60 7.3 8.1
60
70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
90
100 12.1 13.5 15.5 19.3 22.4 22.6
100
110 13.3 14.9 17.0 21.2 24.7 24.9 26.1 110
120 13.7 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160
200 30.9 38.6 44.9 45.2 47.5 47.1 200
*1 = tensile strenght 500N/mm2
34
240 31.6 46.3 53.8 54.3 57.0 56.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
58.8 71.8 72.4 76.0 75.4 320
400
480
540
89.7 90.5 108.6 80.2 94.3 98.1 400 480 540
600
600
660
660
720
1 1 720
design load
(mm)
(kN)
113 160 204 304 409 584 338 416
13.7 21.7 31.6 58.8 91.7 132.1 80.2 98.1
chemical anchors
Vorpa CV.ESF CE
Epoxy acrylate styrene free chemical anchor with European Technical Approval injection anchor for use in masonry - Approval Option 7 pending technical data
Concrete
Natural stone
Design resistance of resin with various stud strenghts and rebar
Wood
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
Rottura acciaio
Ferri da ripresa Fyk = 500 N/mm2 Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 25 28 32
10 12 15 20 25 30 35 40
depth mm
hef 60 6.3 7.6
60
70 7.4 8.8 9.4
70
80 8.4 10.1 10.8 13.3 14.1
90 9.5 11.4 12.1 14.9 15.8
100 10.6 12.6 13.5 16.6 17.6 18.5
110 11.6 13.9 14.8 18.2 19.4 20.3 21.5
120 12.7 15.2 16.2 19.9 21.1 22.2 23.4
80
90
100
110
120
130 13.7 16.4 17.5 21.6 22.9 24.0 25.4 26.1 130
140 14.8 17.7 18.9 23.2 24.6 25.8 27.3 28.2 140
160 16.9 20.2 21.6 26.5 28.2 29.5 31.2 32.2 160
200
240
25.3 27.0 33.2 35.2 36.9 39.1 40.2 200
32.4 39.8 42.2 44.3 46.9 48.3 240
Fd,s
failure
embedment depth 280
46.5 49.3 51.7 54.7 56.3 280
320
400
53.1 56.3 59.1 62.5 64.3 320
500
560
640
720
70.4 73.8 92.3 78.1 97.7 109.4 80.4 100.5 112.6 128.7 400 500 560 640 720
800
design load
(mm)
(kN)
207 270 364 527 775 1065 1371 1739
21.9 34.1 49.2 87.4 136.6 196.5 267.8 349.7
800
Characteristic and Design Load resistances based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non Cracked Concrete Characteristic Resistance (kN) Ø mm
Tension (Nrk)
Shear (Vrk)
Cracked Concrete
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
Shear (Vrd)
Characteristic Resistance (kN)
Shear (Vrec)
Tension (Nrk)
Shear (Vrk)
17,79 9,89 7,06 23,73 9,00 13,18 7,20 9,41 5,14 Not applicable 47,45 26,36 18,83 20,81 11,56 8,26 10 31,21 15,00 17,34 12,00 12,39 8,57 Not applicable 69,37 38,54 27,53 27,45 15,25 10,89 12 43,13 21,00 23,96 16,80 17,11 12,00 Not applicable 94,10 52,28 37,34 39,97 22,21 15,86 16 62,46 39,00 34,70 31,20 24,78 22,29 Not applicable 159,88 88,82 63,45 50,89 28,27 20,20 20 96,13 61,00 53,41 48,80 38,15 34,86 Not applicable 226,20 125,66 89,76 58,28 32,38 23,13 24 122,39 88,00 68,00 70,40 48,57 50,29 Not applicable 279,76 155,42 111,02 71,82 39,90 28,50 Not applicable 30 167,57 207,00 93,10 165,60 66,50 118,29 359,08 199,49 142,49 All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C 8
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Influence of concrete strength on combined pull out and concrete cone resistance C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.98
1.00
1.03
1.06
1.09
1.13
1.16
1.20
Influence of environmental conditions in non cracked concrete
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
M8
M10
M12
M16
M20
M24
M30
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.90
0.88
0.87
0.86
0.85
0.84
0.82
35
Shear (Vrec)
Not applicable
Bond Strength Factors
Concrete Strength N/mm2 (Mpa) non cracked fc=
Shear (Vrd)
Nominal Embedment (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600
chemical anchors
Vorpa CV.ESF CE
Epoxy acrylate styrene free chemical anchor with European Technical Approval injection anchor for use in masonry - Approval Option 7 pending technical data
Concrete
Natural stone
Wood
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
Characteristic and Design Load resistances for REBAR based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non Cracked Concrete Characteristic Resistance (kN) Ø mm
8
10
12
14
16
18
20
22
25
28
32
Tension (Nrk)
Shear (Vrk)
15,47 20,63 41,26 18,66 27,99 62,20 23,28 36,58 79,80 29,45 42,34 103,08 32,41 50,64 129,65 33,93 63,62 152,68 36,64 69,22 162,86 42,16 80,10 185,51 45,03 94,56 225,13 62,07 155,17 310,34 72,96 182,40 364,81
13,95
21,45
31,05
42,45
55,50
69,66
86,55
104,01
135,00
168,75
220,95
Cracked Concrete
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
8,60 11,46 22,92 10,37 15,55 34,56 12,93 20,32 44,33 16,36 23,52 57,27 18,01 28,13 72,03 18,85 35,34 84,82 20,36 38,45 90,48 23,42 44,50 103,06 25,01 52,53 125,07 29,56 73,89 147,78 34,74 86,86 173,72
Shear (Vrd)
9,30
14,30
20,70
28,30
37,00
46,44
57,70
69,34
90,00
112,50
147,30
6,14 8,19 16,37 7,41 11,11 24,68 9,24 14,51 31,67 11,69 16,80 40,90 12,86 20,10 51,45 13,46 25,25 60,59 14,54 27,47 64,63 16,73 31,79 73,61 17,87 37,52 89,34 21,11 52,78 105,56 24,82 62,04 124,08
Characteristic Resistance (kN)
Shear (Vrec)
Tension (Nrk)
Shear (Vrk)
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
Shear (Vrd)
Shear (Vrec)
6,64
Not applicable
Not applicable
Not applicable
10,21
Not applicable
Not applicable
Not applicable
14,79
Not applicable
Not applicable
Not applicable
20,21
Not applicable
Not applicable
Not applicable
26,43
Not applicable
Not applicable
Not applicable
33,17
Not applicable
Not applicable
Not applicable
41,21
Not applicable
Not applicable
Not applicable
49,53
Not applicable
Not applicable
Not applicable
64,29
Not applicable
Not applicable
Not applicable
80,36
Not applicable
Not applicable
Not applicable
105,21
Not applicable
Not applicable
Not applicable
All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C
Bond Strength Factors REBAR Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) non cracked fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.97
1.00
1.03
1.06
1.09
1.12
1.16
1.20
Influence of environmental conditions in non cracked concrete
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
Ø8
Ø 10
Ø 12
Ø 14
Ø 16
Ø 18
Ø 20
Ø 22
Ø 25
Ø 28
Ø 32
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.90
0.90
0.88
0.88
0.88
0.86
0.86
0.84
0.84
0.84
0.84
36
Nominal Embedment (mm) 60 80 160 60 90 200 70 110 240 80 115 280 80 125 320 80 150 360 90 170 400 100 190 440 100 210 500 112 280 560 128 320 640
chemical anchors
Vorpa CV.ESF CE
Epoxy acrylate styrene free chemical anchor with European Technical Approval injection anchor for use in masonry - Approval Option 7 pending technical data Effect of anchor spacing - Tension Anchor spacing (mm) 40 50 60 70 80 90 100 120 150 160 175 200 225 240 250 275 280 300 320 350 400 440 460 500 560
10 0,63 0,65 0,67 0,69 0,72 0,74 0,79 0,86 0,88 0,92 1,00
12
0,63 0,64 0,66 0,68 0,70 0,74 0,80 0,82 0,85 0,90 0,95 1,00
16
0,63 0,64 0,65 0,68 0,73 0,74 0,76 0,80 0,84 0,86 0,87 0,91 0,92 0,95 1,00
Natural stone
Wood
Effect of edge distance - Tension
Stud/Rebar diameter 8 0,64 0,67 0,70 0,73 0,76 0,79 0,82 0,87 0,96 1,00
Concrete
20
0,63 0,65 0,68 0,70 0,71 0,74 0,77 0,79 0,80 0,83 0,84 0,86 0,88 0,92 1,00
24
0,63 0,65 0,66 0,67 0,69 0,72 0,73 0,74 0,76 0,77 0,79 0,81 0,83 0,88 0,92 1,00
30
0,63 0,63 0,64 0,66 0,68 0,69 0,70 0,72 0,73 0,74 0,76 0,78 0,82 0,85 0,87 0,90 1,00
Edge distance (mm) 40 50 60 70 80 90 100 110 120 140 160 180 200 220 240 280
10 0,63 0,70 0,77 0,84 0,91 1,00
12
0,63 0,68 0,74 0,80 0,86 0,92 1,00
37
16
0,63 0,67 0,71 0,76 0,80 0,89 1,00
Marble
Hollow brick
Perforated brick
Perforated cement
Effect of edge distance - Shear
Stud/Rebar diameter 8 0,64 0,73 0,82 0,90 1,00
Solid brick
20
0,63 0,66 0,70 0,77 0,84 0,91 1,00
24
0,64 0,67 0,72 0,78 0,84 0,89 1,00
30
0,63 0,65 0,70 0,76 0,81 0,86 1,00
Edge distance (mm) 40 50 60 70 80 90 100 110 125 140 160 180 200 220 240 280
Stud/Rebar diameter 8 0,25 0,44 0,63 0,81 1,00
10 0,30 0,48 0,65 0,83 1,00
12
0,30 0,44 0,58 0,72 0,86 1,00
16
20
24
0,40 0,53 0,67 0,35 0,80 0,44 1,00 0,58 0,35 0,72 0,46 0,91 0,62 1,00 0,77 0,92 1,00
30
0,30 0,35 0,46 0,57 0,68 0,78 1,00
chemical anchors
Vorpa CV.PSF CE
ancorante ad iniezione a base poliestere senza stirene con valutazione tecnica europea per uso su murature e calcestruzzo non fessurato products group
CV.PSF 300 CE
Concrete
Natural stone
Wood
Solid brick
Suitable • concrete • natural stone • wood • solid brick • marble • hollow brick • solid brick • perforated cement
Marble
Hollow brick
To fix • non-structural fixings • light metal structures • light structural works • solar panel fixing • scaffolding links • floor reinforcement • construction joints • railings
ETAG 001-05 option 7 M8-M16 non cracked concrete
ETAG 029 For masonry & Hollow Walls Use category c, w/d Size M10 Steel elements according to Table 2 Annex 5 of ETA-11/0511
CV.PSF 410 CE
Test report nr. 276986 del 14/12/2010 on wood substrates
CV.PSF 165 CE
Tested for LEED compliancy
38
Styrene Free
Perforated brick
ropic
Thixot
Perforated cement
chemical anchors
Vorpa CV.PSF CE
ancorante ad iniezione a base poliestere senza stirene con valutazione tecnica europea per uso su murature e calcestruzzo non fessurato product information
Concrete
Characteristics • Rapid curing, two part chemical anchoring system based on unsatured Polyester resin in Styrene Free monomers. Applied in one single action this resin will produce a cost effective, strong, chemical resistant fixing. 300ml and 165ml types can be used with a normal silicone gun. Benefits • ETA Approval as injection anchor for use in masonry and non-cracked concrete • Styrene free. Very low odor, ideal as well for indoor usage A+rating • Chemical corrosion resistant • Suitable for close edge applications, no tension on base material • High performances • Available in different formats • Absolutely no leakage
Natural stone
Wood
Hollow brick
1002P 1124 1129
CV. PSF 410 CE CV. PSF 300 CE CV. PSF 165 CE
Hollow brick
Perforated brick
Perforated cement
Suggestion for use • Performance based on clean holes. HAMMER DRILLED – blown and then brushed with a stiff metal brush and blown again.
Solid brick
Description
Marble
Characteristics • Non-flammable and non-hazardous • Cartridge can be used up to the end of the validity date by replacing the static mixer or releasing cartridge with the sealing cap • For applications on hollow materials use the appropriate perforated sleeves.
installation sequence
Code
Solid brick
Content ml
Gun to be used
410 300 165
co-axial silicone silicone
39
chemical anchors
Vorpa CV.PSF CE
ancorante ad iniezione a base poliestere senza stirene con valutazione tecnica europea per uso su murature e calcestruzzo non fessurato technical data
Concrete
Minimum Curing Time Gel-working Time
-10°C * -5°C * 5°C 15°C 25°C 35°C
50 min 40 min 20 min 9 min 5 min 3 min
Minimum curing time Minimum curing time in dry concrete in wet concrete
x2 x2 x2 x2 x2 x2
240 min 180 min 90 min 60 min 30 min 20 min
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
Temperature Range
Concrete Service Temperature
Range I Range II
-40°C to +40°C -40°C to +80°C
Maximum Long Term Maximum Short Term Concrete Temp Concrete Temp
+24°C +50°C
+40°C +80°C
Service temperature range: Range of ambient temperatures after installation and during the lifetime of the anchor. Short term temperature: Temperature within the service temperature range which vary over short intervals, e.g. day/night cycles and freeze/than cycles. Long term temperature: Temperature, within the service temperature range, which will be approximately constant over significant periods of time.
* Resin temperature must be at least 20°C - Full cure 24 hours - All specifications based on supplied mixer
Compressive Strength Flexural Strength Flexural Modulus Tensile Strength E Modulus VOC Content
Wood
Temperature Ranges
Concrete Temperature
Physical Properties
Natural stone
N/mm2 (MPa)
Test Method
43,5 15,9 2803,0 9,3 4874,5 A+
EN ISO 604 / ASTM 695 EN ISO 178 / ASTM 790 EN ISO 178 / ASTM 790 EN ISO 527 / ASTM 638 EN ISO 527 / ASTM 638 -
Loads, Edge and Spacings based on Characteristic bond strengths - Showing steel failure with 5.8 grade steel studding Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
30
Tension (Nrk) 15,71 19,00 19,00 17,53 26,30 30,20 23,09 36,29 43,80 33,38 52,15 81,60 43,60 82,35 127,40 49,01 102,92 183,60 61,07 142,50 292,00
Shear (Vrk)
9,00
15,00
21,00
39,00
61,00
88,00
142,50
Design Resistance (kN)
Recommended Load (kN)
Characteristic distances (mm)
Tension (Nrd)
Tension (Nrec)
Shear (Vrec)
Edge (Ncr,N)
Spacing (Scr,N)
5,14
80
8,57
7,27 9,70 12,70 8,12 12,17 20,10 10,69 16,80 29,20 15,45 24,14 54,40 20,18 38,13 84,90 22,69 47,65 122,40 28,27 65,97 194,50
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
114,00
5,20 6,93 9,07 5,80 8,70 14,36 7,64 12,00 20,86 11,04 17,25 38,86 14,42 27,23 60,64 16,21 34,03 87,43 20,20 47,12 138,93
Min Edge and Spacing
Nominal Embedment
Edge (Ccr,V)
(mm) (Cmin Smin)
(mm)
160
80
40
100
200
90
50
12,00
120
240
110
60
22,29
160
320
125
80
34,86
200
400
180
100
50,29
225
450
220
120
81,43
260
520
280
150
All data is based on correct installation - see instructions No influence of edge and spacing Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C
40
60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600
Hole Hole Max diameter diameter Torque concrete fixture (mm)
(mm)
(Nm)
10
9
10
12
12
20
14
14
40
18
18
80
24
22
120
28
26
160
35
32
200
= Steel failure
chemical anchors
Vorpa CV.PSF CE
ancorante ad iniezione a base poliestere senza stirene con valutazione tecnica europea per uso su murature e calcestruzzo non fessurato technical data
Concrete
Natural stone
Design resistance of resin with various stud strenghts and rebar
Wood
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
= Steel failure
5.8 grade steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
hef failure
embedment depth 60 7.3 8.1
60
70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
90
100 12.1 13.5 15.5 19.3 22.4 22.6
110 12.7 14.9 17.0 21.2 24.7 24.9 26.1
100
110
120 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 20.1 24.7 30.9 35.9 36.2 38.0 37.7 160
200 29.2 38.6 44.9 45.2 47.5 47.1 200
240
46.3 53.8 54.3 57.0 58.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
54.4 71.8 72.4 76.0 75.4 320
400
480
540
600
660
84.9 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660
720
Fd,s design load
(mm)
(kN)
105 148 189 282 379 541 670 825
12.7 20.1 29.2 54.4 84.9 122.4 159.1 194.5
hef
Fd,s
720
8.8 grade steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
failure
embedment depth 60 7.3 8.1
60
70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
90
100 12.1 13.5 15.5 19.3 22.4 22.6
110 13.3 14.9 17.0 21.2 24.7 24.9 26.1
100
110
120 14.5 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 15.8 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 17.0 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 19.5 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160
200 27.1 30.9 38.6 44.9 45.2 47.5 47.1 200
240 37.1 46.3 53.8 54.3 57.0 58.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
61.8 71.8 72.4 76.0 75.4 320
400
480
540
600
660
89.7 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660
720
design load
(mm)
(kN)
161 228 291 434 582 832 1031 1270
19.5 30.9 45.0 83.7 130.7 188.3 244.8 299.2
hef
Fd,s
720
10.9 grade steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
failure
embedment depth 60 7.3 8.1
60
70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
90
100 12.1 13.5 15.5 19.3 22.4 22.6
110 13.3 14.9 17.0 21.2 24.7 24.9 26.1
100
110
120 14.5 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 15.8 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 17.0 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 19.4 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160
200 27.1 30.9 38.6 44.9 45.2 47.5 47.1 200
240 37.1 46.3 53.8 54.3 57.0 58.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
61.8 71.8 72.4 76.0 75.4 320
400
480
540
600
660
89.7 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660
720
design load
(mm)
(kN)
224 318 405 604 811 1159 1435 1768
27.2 43.1 62.6 116.6 182.0 262.2 341.0 416.7
hef
Fd,s
720
A4-70 grade steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
failure
embedment depth 60 7.3 8.1
60
70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
90
100 12.1 13.5 15.5 19.3 22.4 22.6
100
110 13.3 14.9 17.0 21.2 24.7 24.9 26.1 110
120 13.7 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160
200 30.9 38.6 44.9 45.2 47.5 47.1 200
*1 = tensile strenght 500N/mm2
41
240 31.6 46.3 53.8 54.3 57.0 56.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
58.8 71.8 72.4 76.0 75.4 320
400
480
540
89.7 90.5 108.6 80.2 94.3 98.1 400 480 540
600
600
660
660
720
1 1 720
design load
(mm)
(kN)
113 160 204 304 409 584 338 416
13.7 21.7 31.6 58.8 91.7 132.1 80.2 98.1
chemical anchors
Vorpa CV.PSF CE
ancorante ad iniezione a base poliestere senza stirene con valutazione tecnica europea per uso su murature e calcestruzzo non fessurato technical data
Concrete
Natural stone
Design resistance of resin with various stud strenghts and rebar
Wood
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
Rottura acciaio
Ferri da ripresa Fyk = 500 N/mm2 Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 25 28 32
10 12 15 20 25 30 35 40
depth mm
hef 60 6.3 7.6
60
70 7.4 8.8 9.4
70
80 8.4 10.1 10.8 13.3 14.1
90 9.5 11.4 12.1 14.9 15.8
100 10.6 12.6 13.5 16.6 17.6 18.5
110 11.6 13.9 14.8 18.2 19.4 20.3 21.5
120 12.7 15.2 16.2 19.9 21.1 22.2 23.4
80
90
100
110
120
130 13.7 16.4 17.5 21.6 22.9 24.0 25.4 26.1 130
140 14.8 17.7 18.9 23.2 24.6 25.8 27.3 28.2 140
160 16.9 20.2 21.6 26.5 28.2 29.5 31.2 32.2 160
200
240
25.3 27.0 33.2 35.2 36.9 39.1 40.2 200
32.4 39.8 42.2 44.3 46.9 48.3 240
Fd,s
failure
embedment depth 280
46.5 49.3 51.7 54.7 56.3 280
320
53.1 56.3 59.1 62.5 64.3 320
400
500
560
640
720
70.4 73.8 92.3 78.1 97.7 109.4 80.4 100.5 112.6 128.7 400 500 560 640 720
800
design load
(mm)
(kN)
207 270 364 527 776 1065 1371 1739
21.9 34.1 49.2 87.4 136.6 196.5 267.8 349.7
800
technical data Characteristic and Design Load resistances based on characteristic bond strengths for hef 4d (minimum embedment) to 20d - threaded mod Non Cracked Concrete Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
30
Tension (Nrk) 15,71 20,95 41,90 17,53 26,30 58,43 23,09 36,29 79,17 33,38 52,15 133,51 43,60 82,35 193,77 49,01 102,92 235,24 61,07 142,50 305,36
Shear (Vrk)
9,00
15,00
21,00
39,00
61,00
88,00
142,50
Cracked Concrete
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
7,27 9,70 19,40 8,12 12,17 27,05 10,69 16,80 36,65 15,45 24,14 61,81 20,18 38,13 89,71 22,69 47,65 108,91 28,27 65,97 141,37
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
114,00
5,20 6,93 13,86 5,80 8,70 19,32 7,64 12,00 26,18 11,04 17,25 44,15 14,42 27,23 64,08 16,21 34,03 77,79 20,20 47,12 100,98
Shear (Vrec)
Characteristic Resistance (kN) Tension (Nrk)
Shear (Vrk)
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
Shear (Vrd)
Shear (Vrec)
5,14
Not applicable
Not applicable
Not applicable
8,57
Not applicable
Not applicable
Not applicable
12,00
Not applicable
Not applicable
Not applicable
22,29
Not applicable
Not applicable
Not applicable
34,86
Not applicable
Not applicable
Not applicable
50,29
Not applicable
Not applicable
Not applicable
81,43
Not applicable
Not applicable
Not applicable
Nominal Embedment (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600
All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C
42
chemical anchors
Vorpa CV.PSF CE
ancorante ad iniezione a base poliestere senza stirene con valutazione tecnica europea per uso su murature e calcestruzzo non fessurato technical data
Concrete
Natural stone
Wood
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
Characteristic and Design Load resistances for REBAR based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non Cracked Concrete Characteristic Resistance (kN) Ø mm
Tension (Nrk)
Shear (Vrk)
Cracked Concrete
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
Shear (Vrd)
Characteristic Resistance (kN)
Shear (Vrec)
Tension (Nrk)
Shear (Vrk)
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
Shear (Vrd)
Shear (Vrec)
Nominal Embedment (mm)
13,30 6,33 4,52 60 17,73 13.95 8,44 9,30 6,03 6,64 80 Not applicable Not applicable Not applicable 35,47 16,89 12,06 160 15,91 7,58 5,41 60 10 23,86 21,45 11,36 14,30 8,12 10,21 90 Not applicable Not applicable Not applicable 53,03 25,25 18,04 200 19,84 9,45 6,75 70 12 31,18 31,05 14,85 20,70 10,61 14,79 110 Not applicable Not applicable Not applicable 68,04 32,40 23,14 240 27,87 13,27 9,48 80 16 43,54 55,50 20,73 37,00 14,81 26,43 125 Not applicable Not applicable Not applicable 111,47 53,08 37,91 320 32,23 15,35 10,96 90 20 60,88 86,55 28,99 57,30 20,71 41,21 170 Not applicable Not applicable Not applicable 143,26 68,22 48,73 400 38,80 18,48 13,20 100 25 81,48 135,00 38,80 90,00 27,71 64,29 210 Not applicable Not applicable Not applicable 193,99 92,38 65,98 500 46,30 22,05 15,75 112 28 115,76 168,75 55,12 112,50 39,37 80,36 280 Not applicable Not applicable Not applicable 231,52 110,25 78,75 560 54,05 25,74 18,38 128 Not applicable Not applicable Not applicable 32 135,11 220,95 64,34 147,30 45,96 105,22 320 270,23 128,68 91,91 640 All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C 8
Bond Strength Factors - Threaded mod Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) non cracked fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.97
1.00
1.02
1.04
1.07
1.10
1.12
1.15
Influence of environmental conditions in non cracked concrete
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
M8
M10
M12
M16
M20
M24
M30
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.90
0.88
0.87
0.86
0.85
0.84
0.82
Bond Strength Factors - REBAR Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) non cracked fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.97
1.00
1.02
1.04
1.07
1.10
1.12
1.15
Influence of environmental conditions in non cracked concrete
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
Ø8
Ø 10
Ø 12
Ø 16
Ø 20
Ø 25
Ø 28
Ø 32
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.90
0.90
0.88
0.88
0.86
0.86
0.84
0.84
43
chemical anchors
Vorpa CV.PSF CE
ancorante ad iniezione a base poliestere senza stirene con valutazione tecnica europea per uso su murature e calcestruzzo non fessurato technical data Effect of anchor spacing - Tension Anchor spacing (mm) 40 50 60 70 80 90 100 120 150 160 175 200 225 240 250 275 280 300 320 350 400 425 450 480 520
10 0,63 0,65 0,67 0,69 0,72 0,74 0,79 0,86 0,88 0,92 1,00
12
0,63 0,64 0,66 0,68 0,70 0,74 0,80 0,82 0,85 0,90 0,95 1,00
16
0,63 0,64 0,65 0,68 0,73 0,74 0,76 0,80 0,84 0,86 0,87 0,91 0,92 0,95 1,00
Natural stone
Wood
Effect of edge distance - Tension
Stud/Rebar diameter 8 0,64 0,67 0,70 0,73 0,76 0,79 0,82 0,87 0,96 1,00
Concrete
20
0,63 0,65 0,68 0,70 0,71 0,74 0,77 0,79 0,80 0,83 0,84 0,86 0,88 0,92 1,00
24
0,63 0,65 0,66 0,68 0,71 0,74 0,76 0,77 0,80 0,80 0,82 0,85 0,88 0,94 0,97 1,00
30
0,63 0,64 0,65 0,68 0,70 0,72 0,73 0,75 0,76 0,78 0,80 0,83 0,88 0,90 0,93 0,96 1,00
Edge distance (mm) 40 50 60 70 80 90 100 110 120 140 160 180 200 225 250 260
10 0,63 0,70 0,77 0,84 0,91 1,00
12
0,63 0,68 0,74 0,80 0,86 0,92 1,00
16
0,63 0,67 0,71 0,76 0,80 0,89 1,00
Marble
Hollow brick
Perforated brick
Perforated cement
Effect of edge distance - Shear
Stud/Rebar diameter 8 0,64 0,73 0,82 0,90 1,00
Solid brick
20
0,63 0,66 0,70 0,77 0,84 0,91 1,00
24
0,64 0,68 0,76 0,84 0,92 1,00
30
0,63 0,66 0,72 0,78 0,86 0,94 1,00
Edge distance (mm) 40 50 60 70 80 90 100 110 125 140 160 180 200 225 250 280
Stud/Rebar diameter 8 0,25 0,44 0,63 0,81 1,00
10 0,30 0,48 0,65 0,83 1,00
12
0,30 0,44 0,58 0,72 0,86 1,00
16
20
24
0,40 0,53 0,67 0,35 0,80 0,44 1,00 0,58 0,35 0,72 0,45 0,91 0,58 1,00 0,71 0,84 1,00
30
0,30 0,36 0,47 0,59 0,74 0,88 1,00
TECHNICAL DATA FOR APPLICATION ON WOOD Recommended load for applications on glued lamellar wood in conformity with UNI EN 1194 Characteristics of glued lamellar wood UNI EN 1194 Strenght Flexion Parallel Tensile Strenght Perpendicular Tensile Strenght Parallel Compressive Strenght Perpendicular Compressive Strenght Shear Strenght Average Modulus of Elasticity Average Modulus of Shear Volume
N/mm2 fm,k ft,0,k ft,90,k fc,0,k fc,90,k fv,k Eo,mean G mean Pk
Technical data and recommended loads on glued lamellar wood type GL24h Stud size Hole diameter Hole depth (mm) (mm) 80 M8 90 10 M10 100 12 M12 14
GL24 24 16,5 0,4 24 2,7 2,7 11.600 720 380
Test report nr. 276986 del 14/12/2010 on wood substrates
Examples of installation
44
Permissible loads kN 3,3 4,5 8,1
chemical anchors
Vorpa CV.PSF WINTER
Polyester styrene free winter chemical anchor for applications in low ambient temperatures with European Technical Approval opt. 7 for use in non cracked concrete products group
Concrete
Natural stone
Solid brick
Suitable • concrete • natural stone • solid brick • marble • hollow brick • perforated brick • perforated cement
CV.PSF 410 WINTER
Marble
Hollow brick
Perforated brick
Perforated cement
To fix • medium duty metal structures • light structural works • solar panel fixing • construction joints • scaffolding links • railings
WINTER
-10°C
Styrene Free
ETAG 001-05 M8-M16 use in non-cracked concrete
Tested for LEED compliancy
product information Characteristics • High performance, slower curing, two part chemical anchoring system based on unsatured Polyester resin in Styrene Free monomers. Applied in one single action this resin will produce a cost effective, strong, chemical resistant fixing ideal for usage in lower base material temperatures.
Characteristics • Cartridge can be used up to the end of the validity date by replacing the static mixer or releasing cartridge with the sealing cap • For applications on hollow materials use the appropriate perforated sleeves.
Benefits • Ideal for medium duty load applications in low temperature atmosphere, down to -10°C • Styrene free. Very low odor A+ Rating • Chemical corrosion resistant • Suitable for close edge applications, no tension on base material • High performances. Non-flammable and non-hazardous • ETA Approved opt. 7 for use in non cracked concrete
Suggestion for use • Performance based on clean holes. HAMMER DRILLED – blown and then brushed with a stiff metal brush and blown again.
45
chemical anchors
Vorpa CV.PSF WINTER
Polyester styrene free winter chemical anchor for applications in low ambient temperatures with European Technical Approval opt. 7 for use in non cracked concrete installation sequence
Concrete
Natural stone
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
Solid brick
Hollow brick
Code
1168
Description
CV. PSF 410 WINTER
Content ml
Gun to be used
410
co-axial
technical data Minimum Curing Time
Temperature Ranges
Concrete Temperature
Gel-working Time
-20°C* -10°C* -5°C 5°C 15°C 25°C 35°C
70 min 50 min 40 min 20 min 9 min 5 min 3 min
Minimum curing time Minimum curing time in dry concrete in wet concrete
360 min 240 min 180 min 90 min 60 min 30 min 20 min
x2 x2 x2 x2 x2 x2 x2
* Resin temperature must be at least 20°C - Full cure 24 hours - All specifications based on supplied mixer Physical Properties
Compressive Strength Flexural Strength Flexural Modulus Tensile Strength E Modulus VOC Content
N/mm2 (MPa)
Test Method
43,5 15,9 2803 9,3 4874,5 A+
EN ISO 604 / ASTM 695 EN ISO 178 / ASTM 790 EN ISO 178 / ASTM 790 EN ISO 527 / ASTM 638 EN ISO 527 / ASTM 638 -
Temperature Range
Concrete Service Temperature
Range I Range II
-40°C to +40°C -40°C to +80°C
Maximum Long Term Maximum Short Term Concrete Temp Concrete Temp
+24°C +50°C
+40°C +80°C
Service temperature range: Range of ambient temperatures after installation and during the lifetime of the anchor. Short term temperature: Temperature within the service temperature range which vary over short intervals, e.g. day/night cycles and freeze/than cycles. Long term temperature: Temperature, within the service temperature range, which will be approximately constant over significant periods of time.
46
chemical anchors
Vorpa CV.PSF WINTER
Polyester styrene free winter chemical anchor for applications in low ambient temperatures with European Technical Approval opt. 7 for use in non cracked concrete technical data
Concrete
Natural stone
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
Loads, Edge and Spacings based on Characteristic bond strengths - Showing steel failure with 5.8 grade steel studding Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
30
Tension (Nrk)
Shear (Vrk)
15,71 19,00 19,00 17,53 26,30 30,20 23,09 36,29 43,80 33,38 52,15 81,60 43,60 82,35 127,40 49,01 102,92 183,60 61,07 142,50 292,00
9,00
15,00
21,00
39,00
61,00
88,00
142,50
Design Resistance (kN)
Recommended Load (kN)
Characteristic distances (mm)
Tension (Nrd)
Tension (Nrec)
Shear (Vrec)
Edge (Ncr,N)
Spacing (Scr,N)
5,14
80
8,57
7,27 9,70 12,70 8,12 12,17 20,10 10,69 16,80 29,20 15,45 24,14 54,40 20,18 38,13 84,90 22,69 47,65 122,40 28,27 65,97 194,50
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
114,00
5,20 6,93 9,07 5,80 8,70 14,36 7,64 12,00 20,86 11,04 17,25 38,86 14,42 27,23 60,64 16,21 34,03 87,43 20,20 47,12 138,93
Min Edge and Spacing
Nominal Embedment
Edge (Ccr,V)
(mm) (Cmin Smin)
(mm)
160
80
40
100
200
90
50
12,00
120
240
110
60
22,29
160
320
125
80
34,86
200
400
180
100
50,29
225
450
220
120
81,43
260
520
280
150
Hole Hole Max diameter diameter Torque concrete fixture
60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600
(mm)
(mm)
(Nm)
10
9
10
12
12
20
14
14
40
18
18
80
24
22
120
28
26
160
35
32
200
All data is based on correct installation - see instructions No influence of edge and spacing Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C
= Steel failure
technical data Design resistance of resin with various stud strenghts and rebar
= Steel failure
High bond reinforcing bars Fyk = 500 N/mm2 Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 25 28 32
10 12 15 20 25 30 35 40
depth mm
hef failure
embedment depth 60 6.3 7.6
60
70 7.4 8.8 9.4
70
80 8.4 10.1 10.8 13.3 14.1
90 9.5 11.4 12.1 14.9 15.8
100 10.6 12.6 13.5 16.6 17.6 18.5
110 11.6 13.9 14.8 18.2 19.4 20.3 21.5
120 12.7 15.2 16.2 19.9 21.1 22.2 23.4
80
90
100
110
120
130 13.7 16.4 17.5 21.6 22.9 24.0 25.4 26.1 130
140 14.8 17.7 18.9 23.2 24.6 25.8 27.3 28.2 140
160 16.9 20.2 21.6 26.5 28.2 29.5 31.2 32.2 160
200 25.3 27.0 33.2 35.2 36.9 39.1 40.2 200
47
240 32.4 39.8 42.2 44.3 46.9 48.3 240
280
46.5 49.3 51.7 54.7 56.3 280
320
53.1 56.3 59.1 62.5 64.3 320
400
500
560
640
720
70.4 73.8 92.3 78.1 97.7 109.4 80.4 100.5 112.6 128.7 400 500 560 640 720
800
800
Fd,s design load
(mm)
(kN)
207 270 364 527 776 1065 1371 1739
21.9 34.1 49.2 87.4 136.6 196.5 267.8 349.7
chemical anchors
Vorpa CV.PSF WINTER
Polyester styrene free winter chemical anchor for applications in low ambient temperatures with European Technical Approval opt. 7 for use in non cracked concrete technical data
Concrete
Design resistance of resin with various stud strenghts and rebar
Natural stone
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
= Steel failure
5.8 grade steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
hef failure
embedment depth 60 7.3 8.1
60
70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
90
100 12.1 13.5 15.5 19.3 22.4 22.6
110 12.7 14.9 17.0 21.2 24.7 24.9 26.1
100
110
120 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 20.1 24.7 30.9 35.9 36.2 38.0 37.7 160
200 29.2 38.6 44.9 45.2 47.5 47.1 200
240
46.3 53.8 54.3 57.0 58.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
54.4 71.8 72.4 76.0 75.4 320
400
480
540
600
660
84.9 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660
720
Fd,s design load
(mm)
(kN)
105 148 189 282 379 541 670 825
12.7 20.1 29.2 54.4 84.9 122.4 159.1 194.5
hef
Fd,s
720
8.8 grade steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
failure
embedment depth 60 7.3 8.1
60
70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
90
100 12.1 13.5 15.5 19.3 22.4 22.6
110 13.3 14.9 17.0 21.2 24.7 24.9 26.1
100
110
120 14.5 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 15.8 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 17.0 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 19.5 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160
200 27.1 30.9 38.6 44.9 45.2 47.5 47.1 200
240 37.1 46.3 53.8 54.3 57.0 58.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
61.8 71.8 72.4 76.0 75.4 320
400
480
540
600
660
89.7 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660
720
design load
(mm)
(kN)
161 228 291 434 582 832 1031 1270
19.5 30.9 45.0 83.7 130.7 188.3 244.8 299.2
hef
Fd,s
720
10.9 grade steel studding Ø
Ø
Stud
Hole
diameter
diameter
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
failure
embedment depth 60 7.3 8.1
60
70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
90
100 12.1 13.5 15.5 19.3 22.4 22.6
110 13.3 14.9 17.0 21.2 24.7 24.9 26.1
100
110
120 14.5 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 15.8 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 17.0 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 19.4 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160
200 27.1 30.9 38.6 44.9 45.2 47.5 47.1 200
240 37.1 46.3 53.8 54.3 57.0 58.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
61.8 71.8 72.4 76.0 75.4 320
400
480
540
600
660
89.7 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660
720
design load
(mm)
(kN)
224 318 405 604 811 1159 1435 1768
27.2 43.1 62.6 116.6 182.0 262.2 341.0 416.7
hef
Fd,s
720
A4-70 grade steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
failure
embedment depth 60 7.3 8.1
60
70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
90
100 12.1 13.5 15.5 19.3 22.4 22.6
100
110 13.3 14.9 17.0 21.2 24.7 24.9 26.1 110
120 13.7 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160
200 30.9 38.6 44.9 45.2 47.5 47.1 200
*1 = tensile strenght 500N/mm2
48
240 31.6 46.3 53.8 54.3 57.0 56.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
58.8 71.8 72.4 76.0 75.4 320
400
480
540
89.7 90.5 108.6 80.2 94.3 98.1 400 480 540
600
600
660
660
720
1 1 720
design load
(mm)
(kN)
113 160 204 304 409 584 338 416
13.7 21.7 31.6 58.8 91.7 132.1 80.2 98.1
chemical anchors
Vorpa CV.PSF WINTER
Polyester styrene free winter chemical anchor for applications in low ambient temperatures with European Technical Approval opt. 7 for use in non cracked concrete technical data
Concrete
Natural stone
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
Characteristic and Design Load resistances based on characteristic bond strengths for hef 4d (minimum embedment) to 20d - threaded mod Non Cracked Concrete Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
30
Tension (Nrk)
Shear (Vrk)
15,71 20,95 41,90 17,53 26,30 58,43 23,09 36,29 79,17 33,38 52,15 133,51 43,60 82,35 193,77 49,01 102,92 235,24 61,07 142,50 305,36
9,00
15,00
21,00
39,00
61,00
88,00
142,50
Cracked Concrete
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
7,27 9,70 19,40 8,12 12,17 27,05 10,69 16,80 36,65 15,45 24,14 61,81 20,18 38,13 89,71 22,69 47,65 108,91 28,27 65,97 141,37
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
114,00
5,20 6,93 13,86 5,80 8,70 19,32 7,64 12,00 26,18 11,04 17,25 44,15 14,42 27,23 64,08 16,21 34,03 77,79 20,20 47,12 100,98
Characteristic Resistance (kN)
Shear (Vrec)
Tension (Nrk)
Shear (Vrk)
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
Shear (Vrd)
Shear (Vrec)
5,14
Not applicable
Not applicable
Not applicable
8,57
Not applicable
Not applicable
Not applicable
12,00
Not applicable
Not applicable
Not applicable
22,29
Not applicable
Not applicable
Not applicable
34,86
Not applicable
Not applicable
Not applicable
50,29
Not applicable
Not applicable
Not applicable
81,43
Not applicable
Not applicable
Not applicable
Nominal Embedment (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600
All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C
Bond Strength Factors - Threaded mod Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) non cracked fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.97
1.00
1.02
1.04
1.07
1.10
1.12
1.15
Influence of environmental conditions in non cracked concrete
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
M8
M10
M12
M16
M20
M24
M30
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.90
0.88
0.87
0.86
0.85
0.84
0.82
49
chemical anchors
Vorpa CV.PSF WINTER
Polyester styrene free winter chemical anchor for applications in low ambient temperatures with European Technical Approval opt. 7 for use in non cracked concrete technical data
Concrete
Natural stone
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
Characteristic and Design Load resistances for REBAR based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non Cracked Concrete Characteristic Resistance (kN) Ø mm
8
10
12
16
20
25
28
32
Tension (Nrk)
Shear (Vrk)
13,30 17,73 35,47 15,91 23,86 53,03 19,84 31,18 68,04 27,87 43,54 111,47 32,23 60,88 143,26 38,80 81,48 193,99 46,30 115,76 231,52 54,05 135,11 270,23
13.95
21,45
31,05
55,50
86,55
135,00
168,75
220,95
Cracked Concrete
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
Shear (Vrd)
6,33 8,44 16,89 7,58 11,36 25,25 9,45 14,85 32,40 13,27 20,73 53,08 15,35 28,99 68,22 18,48 38,80 92,38 22,05 55,12 110,25 25,74 64,34 128,68
9,30
14,30
20,70
37,00
57,30
90,00
112,50
147,30
4,52 6,03 12,06 5,41 8,12 18,04 6,75 10,61 23,14 9,48 14,81 37,91 10,96 20,71 48,73 13,20 27,71 65,98 15,75 39,37 78,75 18,38 45,96 91,91
Characteristic Resistance (kN)
Shear (Vrec)
Tension (Nrk)
Shear (Vrk)
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
Shear (Vrd)
Shear (Vrec)
6,64
Not applicable
Not applicable
Not applicable
10,21
Not applicable
Not applicable
Not applicable
14,79
Not applicable
Not applicable
Not applicable
26,43
Not applicable
Not applicable
Not applicable
41,21
Not applicable
Not applicable
Not applicable
64,29
Not applicable
Not applicable
Not applicable
80,36
Not applicable
Not applicable
Not applicable
105,22
Not applicable
Not applicable
Not applicable
Nominal Embedment (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 500 112 280 560 128 320 640
All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C
Bond Strength Factors - REBAR Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) non cracked fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.97
1.00
1.02
1.04
1.07
1.10
1.12
1.15
Influence of environmental conditions in non cracked concrete
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
Ø8
Ø 10
Ø 12
Ø 16
Ø 20
Ø 25
Ø 28
Ø 32
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.90
0.90
0.88
0.88
0.86
0.86
0.84
0.84
50
chemical anchors
Vorpa CV.PSF WINTER
Polyester styrene free winter chemical anchor for applications in low ambient temperatures with European Technical Approval opt. 7 for use in non cracked concrete technical data Effect of anchor spacing - Tension Anchor spacing (mm) 40 50 60 70 80 90 100 120 150 160 175 200 225 240 250 275 280 300 320 350 400 425 450 480 520
10 0,63 0,65 0,67 0,69 0,72 0,74 0,79 0,86 0,88 0,92 1,00
12
0,63 0,64 0,66 0,68 0,70 0,74 0,80 0,82 0,85 0,90 0,95 1,00
16
0,63 0,64 0,65 0,68 0,73 0,74 0,76 0,80 0,84 0,86 0,87 0,91 0,92 0,95 1,00
Natural stone
Effect of edge distance - Tension
Stud/Rebar diameter 8 0,64 0,67 0,70 0,73 0,76 0,79 0,82 0,87 0,96 1,00
Concrete
20
0,63 0,65 0,68 0,70 0,71 0,74 0,77 0,79 0,80 0,83 0,84 0,86 0,88 0,92 1,00
24
0,63 0,65 0,66 0,68 0,71 0,74 0,76 0,77 0,80 0,80 0,82 0,85 0,88 0,94 0,97 1,00
30
0,63 0,64 0,65 0,68 0,70 0,72 0,73 0,75 0,76 0,78 0,80 0,83 0,88 0,90 0,93 0,96 1,00
Edge distance (mm) 40 50 60 70 80 90 100 110 120 140 160 180 200 225 250 260
10 0,63 0,70 0,77 0,84 0,91 1,00
12
0,63 0,68 0,74 0,80 0,86 0,92 1,00
51
16
0,63 0,67 0,71 0,76 0,80 0,89 1,00
Marble
Hollow brick
Perforated brick
Perforated cement
Effect of edge distance - Shear
Stud/Rebar diameter 8 0,64 0,73 0,82 0,90 1,00
Solid brick
20
0,63 0,66 0,70 0,77 0,84 0,91 1,00
24
0,64 0,68 0,76 0,84 0,92 1,00
30
0,63 0,66 0,72 0,78 0,86 0,94 1,00
Edge distance (mm) 40 50 60 70 80 90 100 110 125 140 160 180 200 225 250 280
Stud/Rebar diameter 8 0,25 0,44 0,63 0,81 1,00
10 0,30 0,48 0,65 0,83 1,00
12
0,30 0,44 0,58 0,72 0,86 1,00
16
20
24
0,40 0,53 0,67 0,35 0,80 0,44 1,00 0,58 0,35 0,72 0,45 0,91 0,58 1,00 0,71 0,84 1,00
30
0,30 0,36 0,47 0,59 0,74 0,88 1,00
chemical anchors
Vorpa CV.PSF TROPICAL Polyester styrene free tropical chemical anchor for application in high ambient temperatures.
Concrete
Natural stone
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
products group Suitable • concrete • natural stone • solid brick • marble • hollow brick • perforated brick • perforated cement
CV.PSF TROPICAL 410
Tested for LEED compliancy
To fix • non-structural fixings • light metal works • light structural works • solar panel fixing • scaffolding links • floor reinforcement • construction joints • railings
Styrene Free
product information Characteristics • High performance, slower curing, two part chemical anchoring system based on Polyester Styrene Free resin. Applied in one single action this resin will produce a strong, chemical resistant fixing which can be used at temperatures of up to 45°C.
Characteristics • Cartridge can be used up to the end of the validity date by replacing the static mixer or releasing cartridge with the sealing cap • For applications on hollow materials use the appropriate perforated sleeves.
Benefits • Ideal for medium duty load applications in high temperature atmosphere, up to 45°C • Styrene free. Very low odor A+rating • Chemical corrosion resistant • Suitable for close edge applications, no tension on base material • High performances • Absolutely no leakage • Non-flammable and non-hazardous
Suggestion for use • Performance based on clean holes. HAMMER DRILLED – blown and then brushed with a stiff metal brush and blown again.
52
chemical anchors
Vorpa CV.PSF TROPICAL Polyester styrene free tropical chemical anchor for application in high ambient temperatures.
Concrete
Natural stone
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
installation sequence Solid brick
Hollow brick
Code
1159
Description
CV. PSF TROPICAL
Content ml
Gun to be used
410
co-axial
technical data Temperature Ranges
Minimum Curing Time Concrete Temperature
Gel-working Time
5°C 15°C 25°C 35°C 45°C
45 min 18 min 10 min 5 min 2 min
Minimum curing time Minimum curing time in dry concrete in wet concrete
120 min 75 min 45 min 30 min 15 min
x2 x2 x2 x2 x2
- Full cure 24 hours - All specifications based on supplied mixer
Physical Properties
Compressive Strength Flexural Strength Flexural Modulus Tensile Strength E Modulus VOC Content
N/mm2 (MPa)
Test Method
43,5 15,9 2803,0 9,3 4874,5 A+
EN ISO 604 / ASTM 695 EN ISO 178 / ASTM 790 EN ISO 178 / ASTM 790 EN ISO 527 / ASTM 638 EN ISO 527 / ASTM 638 -
Temperature Range
Concrete Service Temperature
Range I Range II
-40°C to +40°C -40°C to +80°C
Maximum Long Term Maximum Short Term Concrete Temp Concrete Temp
+24°C +50°C
+40°C +80°C
Service temperature range: Range of ambient temperatures after installation and during the lifetime of the anchor. Short term temperature: Temperature within the service temperature range which vary over short intervals, e.g. day/night cycles and freeze/than cycles. Long term temperature: Temperature, within the service temperature range, which will be approximately constant over significant periods of time.
53
chemical anchors
Vorpa CV.PSF TROPICAL Polyester styrene free tropical chemical anchor for application in high ambient temperatures.
Concrete
Natural stone
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
technical data Loads, Edge and Spacings based on Characteristic bond strengths - Showing steel failure with 5.8 grade steel studding Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
30
Tension (Nrk)
Shear (Vrk)
15,71 19,00 19,00 17,53 26,30 30,20 23,09 36,29 43,80 33,38 52,15 81,60 43,60 82,35 127,40 49,01 102,92 183,60 61,07 142,50 292,00
9,00
15,00
21,00
39,00
61,00
88,00
142,50
Design Resistance (kN)
Recommended Load (kN)
Characteristic distances (mm)
Tension (Nrd)
Tension (Nrec)
Shear (Vrec)
Edge (Ncr,N)
Spacing (Scr,N)
5,14
80
8,57
7,27 9,70 12,70 8,12 12,17 20,10 10,69 16,80 29,20 15,45 24,14 54,40 20,18 38,13 84,90 22,69 47,65 122,40 28,27 65,97 194,50
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
114,00
5,20 6,93 9,07 5,80 8,70 14,36 7,64 12,00 20,86 11,04 17,25 38,86 14,42 27,23 60,64 16,21 34,03 87,43 20,20 47,12 138,93
Min Edge and Spacing
Nominal Embedment
Edge (Ccr,V)
(mm) (Cmin Smin)
(mm)
160
80
40
100
200
90
50
12,00
120
240
110
60
22,29
160
320
125
80
34,86
200
400
180
100
50,29
225
450
220
120
81,43
260
520
280
150
Hole Hole Max diameter diameter Torque concrete fixture
60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600
(mm)
(mm)
(Nm)
10
9
10
12
12
20
14
14
40
18
18
80
24
22
120
28
26
160
35
32
200
All data is based on correct installation - see instructions No influence of edge and spacing Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C
= Steel failure
technical data Design resistance of resin with various stud strenghts and rebar
= Steel failure
5.8 grade steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
hef failure
embedment depth 60 7.3 8.1
60
70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
90
100 12.1 13.5 15.5 19.3 22.4 22.6
110 12.7 14.9 17.0 21.2 24.7 24.9 26.1
100
110
120 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 20.1 24.7 30.9 35.9 36.2 38.0 37.7 160
200 29.2 38.6 44.9 45.2 47.5 47.1 200
54
240
46.3 53.8 54.3 57.0 58.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
54.4 71.8 72.4 76.0 75.4 320
400
480
540
600
660
84.9 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660
720
720
Fd,s design load
(mm)
(kN)
105 148 189 282 379 541 670 825
12.7 20.1 29.2 54.4 84.9 122.4 159.1 194.5
chemical anchors
Vorpa CV.PSF TROPICAL Polyester styrene free tropical chemical anchor for application in high ambient temperatures.
Concrete
Natural stone
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
technical data 8.8 grade steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
= Steel failure hef failure
embedment depth 60 7.3 8.1
60
70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
100 12.1 13.5 15.5 19.3 22.4 22.6
110 13.3 14.9 17.0 21.2 24.7 24.9 26.1
100
110
90
120 14.5 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 15.8 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 17.0 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 19.5 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160
200 27.1 30.9 38.6 44.9 45.2 47.5 47.1 200
240 37.1 46.3 53.8 54.3 57.0 58.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
61.8 71.8 72.4 76.0 75.4 320
400
480
540
600
660
89.7 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660
720
Fd,s design load
(mm)
(kN)
161 228 291 434 582 832 1031 1270
19.5 30.9 45.0 83.7 130.7 188.3 244.8 299.2
hef
Fd,s
720
10.9 grade steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
failure
embedment depth 60 7.3 8.1
60
70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
100 12.1 13.5 15.5 19.3 22.4 22.6
110 13.3 14.9 17.0 21.2 24.7 24.9 26.1
100
110
90
120 14.5 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 15.8 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 17.0 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 19.4 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160
200 27.1 30.9 38.6 44.9 45.2 47.5 47.1 200
240 37.1 46.3 53.8 54.3 57.0 58.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
61.8 71.8 72.4 76.0 75.4 320
400
480
540
600
660
89.7 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660
720
design load
(mm)
(kN)
224 318 405 604 811 1159 1435 1768
27.2 43.1 62.6 116.6 182.0 262.2 341.0 416.7
hef
Fd,s
720
A4-70 grade steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
failure
embedment depth 60 7.3 8.1
60
70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2
70
80
100 12.1 13.5 15.5 19.3 22.4 22.6
90
100
110 13.3 14.9 17.0 21.2 24.7 24.9 26.1 110
120 13.7 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120
130 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130
140 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140
160 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160
200 30.9 38.6 44.9 45.2 47.5 47.1 200
240 31.6 46.3 53.8 54.3 57.0 56.6 240
280
54.1 62.8 63.3 66.5 66.0 280
320
58.8 71.8 72.4 76.0 75.4 320
400
480
540
89.7 90.5 108.6 80.2 94.3 98.1 400 480 540
600
600
660
660
720
1 1 720
design load
(mm)
(kN)
113 160 204 304 409 584 338 416
13.7 21.7 31.6 58.8 91.7 132.1 80.2 98.1
hef
Fd,s
*1 = tensile strenght 500N/mm2
High bond reinforcing bars = 500 N/mm2 Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 25 28 32
10 12 15 20 25 30 35 40
depth mm
failure
embedment depth 60 6.3 7.6
60
70 7.4 8.8 9.4
70
80 8.4 10.1 10.8 13.3 14.1
90 9.5 11.4 12.1 14.9 15.8
100 10.6 12.6 13.5 16.6 17.6 18.5
110 11.6 13.9 14.8 18.2 19.4 20.3 21.5
120 12.7 15.2 16.2 19.9 21.1 22.2 23.4
80
90
100
110
120
130 13.7 16.4 17.5 21.6 22.9 24.0 25.4 26.1 130
140 14.8 17.7 18.9 23.2 24.6 25.8 27.3 28.2 140
160 16.9 20.2 21.6 26.5 28.2 29.5 31.2 32.2 160
200 25.3 27.0 33.2 35.2 36.9 39.1 40.2 200
55
240 32.4 39.8 42.2 44.3 46.9 48.3 240
280
46.5 49.3 51.7 54.7 56.3 280
320
53.1 56.3 59.1 62.5 64.3 320
400
500
560
640
720
70.4 73.8 92.3 78.1 97.7 109.4 80.4 100.5 112.6 128.7 400 500 560 640 720
800
800
design load
(mm)
(kN)
207 270 364 527 776 1065 1371 1739
21.9 34.1 49.2 87.4 136.6 196.5 267.8 349.7
chemical anchors
Vorpa CV.PSF TROPICAL Polyester styrene free tropical chemical anchor for application in high ambient temperatures.
Concrete
Natural stone
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
technical data Characteristic and Design Load resistances based on characteristic bond strengths for hef 4d (minimum embedment) to 20d - threaded mod Non Cracked Concrete Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
30
Tension (Nrk)
Shear (Vrk)
15,71 20,95 41,90 17,53 26,30 58,43 23,09 36,29 79,17 33,38 52,15 133,51 43,60 82,35 193,77 49,01 102,92 235,24 61,07 142,50 305,36
9,00
15,00
21,00
39,00
61,00
88,00
142,50
Cracked Concrete
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
7,27 9,70 19,40 8,12 12,17 27,05 10,69 16,80 36,65 15,45 24,14 61,81 20,18 38,13 89,71 22,69 47,65 108,91 28,27 65,97 141,37
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
114,00
5,20 6,93 13,86 5,80 8,70 19,32 7,64 12,00 26,18 11,04 17,25 44,15 14,42 27,23 64,08 16,21 34,03 77,79 20,20 47,12 100,98
Characteristic Resistance (kN)
Shear (Vrec)
Tension (Nrk)
Shear (Vrk)
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
Shear (Vrd)
Shear (Vrec)
5,14
Not applicable
Not applicable
Not applicable
8,57
Not applicable
Not applicable
Not applicable
12,00
Not applicable
Not applicable
Not applicable
22,29
Not applicable
Not applicable
Not applicable
34,86
Not applicable
Not applicable
Not applicable
50,29
Not applicable
Not applicable
Not applicable
81,43
Not applicable
Not applicable
Not applicable
Nominal Embedment (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600
All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C
Bond Strength Factors - Threaded mod Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) non cracked fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.97
1.00
1.02
1.04
1.07
1.10
1.12
1.15
Influence of environmental conditions in non cracked concrete
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
M8
M10
M12
M16
M20
M24
M30
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.90
0.88
0.87
0.86
0.85
0.84
0.82
56
chemical anchors
Vorpa CV.PSF TROPICAL Polyester styrene free tropical chemical anchor for application in high ambient temperatures.
Concrete
Natural stone
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
technical data Characteristic and Design Load resistances for REBAR based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non Cracked Concrete Characteristic Resistance (kN) Ø mm
8
10
12
16
20
25
28
32
Tension (Nrk)
Shear (Vrk)
13,30 17,73 35,47 15,91 23,86 53,03 19,84 31,18 68,04 27,87 43,54 111,47 32,23 60,88 143,26 38,80 81,48 193,99 46,30 115,76 231,52 54,05 135,11 270,23
13.95
21,45
31,05
55,50
86,55
135,00
168,75
220,95
Cracked Concrete
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
Shear (Vrd)
6,33 8,44 16,89 7,58 11,36 25,25 9,45 14,85 32,40 13,27 20,73 53,08 15,35 28,99 68,22 18,48 38,80 92,38 22,05 55,12 110,25 25,74 64,34 128,68
9,30
14,30
20,70
37,00
57,30
90,00
112,50
147,30
4,52 6,03 12,06 5,41 8,12 18,04 6,75 10,61 23,14 9,48 14,81 37,91 10,96 20,71 48,73 13,20 27,71 65,98 15,75 39,37 78,75 18,38 45,96 91,91
Characteristic Resistance (kN)
Shear (Vrec)
Tension (Nrk)
Shear (Vrk)
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
Shear (Vrd)
Shear (Vrec)
6,64
Not applicable
Not applicable
Not applicable
10,21
Not applicable
Not applicable
Not applicable
14,79
Not applicable
Not applicable
Not applicable
26,43
Not applicable
Not applicable
Not applicable
41,21
Not applicable
Not applicable
Not applicable
64,29
Not applicable
Not applicable
Not applicable
80,36
Not applicable
Not applicable
Not applicable
105,22
Not applicable
Not applicable
Not applicable
Nominal Embedment (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 500 112 280 560 128 320 640
All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C
Bond Strength Factors - REBAR Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) non cracked fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.97
1.00
1.02
1.04
1.07
1.10
1.12
1.15
Influence of environmental conditions in non cracked concrete
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
Ø8
Ø 10
Ø 12
Ø 16
Ø 20
Ø 25
Ø 28
Ø 32
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.90
0.90
0.88
0.88
0.86
0.86
0.84
0.84
57
chemical anchors
Vorpa CV.PSF TROPICAL Polyester styrene free tropical chemical anchor for application in high ambient temperatures.
Concrete
Natural stone
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
technical data Effect of anchor spacing - Tension Anchor spacing (mm) 40 50 60 70 80 90 100 120 150 160 175 200 225 240 250 275 280 300 320 350 400 425 450 480 520
Effect of edge distance - Tension
Stud/Rebar diameter 8 0,64 0,67 0,70 0,73 0,76 0,79 0,82 0,87 0,96 1,00
10 0,63 0,65 0,67 0,69 0,72 0,74 0,79 0,86 0,88 0,92 1,00
12
0,63 0,64 0,66 0,68 0,70 0,74 0,80 0,82 0,85 0,90 0,95 1,00
16
0,63 0,64 0,65 0,68 0,73 0,74 0,76 0,80 0,84 0,86 0,87 0,91 0,92 0,95 1,00
20
0,63 0,65 0,68 0,70 0,71 0,74 0,77 0,79 0,80 0,83 0,84 0,86 0,88 0,92 1,00
24
0,63 0,65 0,66 0,68 0,71 0,74 0,76 0,77 0,80 0,80 0,82 0,85 0,88 0,94 0,97 1,00
30
0,63 0,64 0,65 0,68 0,70 0,72 0,73 0,75 0,76 0,78 0,80 0,83 0,88 0,90 0,93 0,96 1,00
Edge distance (mm) 40 50 60 70 80 90 100 110 120 140 160 180 200 225 250 260
Effect of edge distance - Shear
Stud/Rebar diameter 8 0,64 0,73 0,82 0,90 1,00
10 0,63 0,70 0,77 0,84 0,91 1,00
12
0,63 0,68 0,74 0,80 0,86 0,92 1,00
58
16
0,63 0,67 0,71 0,76 0,80 0,89 1,00
20
0,63 0,66 0,70 0,77 0,84 0,91 1,00
24
0,64 0,68 0,76 0,84 0,92 1,00
30
0,63 0,66 0,72 0,78 0,86 0,94 1,00
Edge distance (mm) 40 50 60 70 80 90 100 110 125 140 160 180 200 225 250 280
Stud/Rebar diameter 8 0,25 0,44 0,63 0,81 1,00
10 0,30 0,48 0,65 0,83 1,00
12
0,30 0,44 0,58 0,72 0,86 1,00
16
20
24
0,40 0,53 0,67 0,35 0,80 0,44 1,00 0,58 0,35 0,72 0,45 0,91 0,58 1,00 0,71 0,84 1,00
30
0,30 0,36 0,47 0,59 0,74 0,88 1,00
chemical anchors
Vorpa CV.PE
Polyester chemical anchor
Concrete
Natural stone
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
products group Suitable • concrete • natural stone • solid brick • marble • hollow brick • perforated brick • perforated cement
To fix • non-structural fixings • light metal structures • light structural works • solar panel fixing • scaffolding links • floor reinforcement • construction joints • railings
ETAG 029 Use Category:c,w/d size M8, M10, M12 for use in masonry
CV.PE 300 Tested for LEED compliancy
CV.PE 410
59
n° AT-15-6895/2011
chemical anchors
Vorpa CV.PE
Polyester chemical anchor
Concrete
Natural stone
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
product information Characteristics • Rapid curing, two part chemical anchoring system. Applied in one single action this resin will produce a chemical resistant fixing which is cost effective for usage in aerated concrete or hollow wall applications, as well as general purpose. Benefits • Chemical corrosion resistant • Suitable for close edge applications, no tension on base material • High performances • Available in different formats • Absolutely no leakage • Non-flammable
Characteristics • Cartridge can be used up to the end of the validity date by replacing the static mixer or releasing cartridge with the sealing cap • For applications on hollow materials use the appropriate perforated sleeves. Suggestion for use • Performance based on clean holes. HAMMER DRILLED – blown and then brushed with a stiff metal brush and blown again.
installation sequence Solid brick
Hollow brick
Code
Description
Content ml
Gun to be used
1002B 1125
CV. PE 410 CV. PE 300
410 300
co-axial silicone
60
chemical anchors
Vorpa CV.PE
Polyester chemical anchor
Concrete
Natural stone
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
technical data Minimum Curing Time
Temperature Ranges
Concrete Temperature
Gel-working Time
-10°C * -5°C * 5°C 15°C 25°C 35°C
50 min 40 min 20 min 9 min 5 min 3 min
Minimum curing time Minimum curing time in dry concrete in wet concrete
x2 x2 x2 x2 x2 x2
240 min 180 min 90 min 60 min 30 min 20 min
Compressive Strength Flexural Strength Flexural Modulus Tensile Strength E Modulus VOC Content
Concrete Service Temperature
Range I Range II
-40°C to +40°C -40°C to +80°C
Maximum Long Term Maximum Short Term Concrete Temp Concrete Temp
+24°C +50°C
+40°C +80°C
Service temperature range: Range of ambient temperatures after installation and during the lifetime of the anchor. Short term temperature: Temperature within the service temperature range which vary over short intervals, e.g. day/night cycles and freeze/than cycles. Long term temperature: Temperature, within the service temperature range, which will be approximately constant over significant periods of time.
* Resin temperature must be at least 20°C - Full cure 24 hours - All specifications based on supplied mixer Physical Properties
Temperature Range
N/mm2 (MPa)
Test Method
41,8 14,1 2589,6 7,4 4365,5 A+
EN ISO 604 / ASTM 695 EN ISO 178 / ASTM 790 EN ISO 178 / ASTM 790 EN ISO 527 / ASTM 638 EN ISO 527 / ASTM 638 -
Loads, Edge and Spacings based on Characteristic bond strengths - Showing steel failure with 5.8 grade steel studding Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
30
Tension (Nrk) 14,85 19,00 19,00 16,57 24,85 30,20 21,82 34,29 43,80 31,54 49,28 81,60 41,20 77,82 127,40 46,31 97,26 183,60 57,70 134,66 292,00
Shear (Vrk)
9,00
15,00
21,00
39,00
61,00
88,00
142,50
Design Resistance (kN)
Recommended Load (kN)
Characteristic distances (mm)
Tension (Nrd)
Tension (Nrec)
Shear (Vrec)
Edge (Ncr,N)
Spacing (Scr,N)
5,14
80
8,57
6,87 9,17 12,70 7,67 11,50 20,10 10,10 15,88 29,20 14,60 22,81 54,40 19,07 36,03 84,90 21,44 45,03 122,40 26,71 62,34 194,50
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
114,00
4,91 6,55 9,07 5,48 8,22 14,36 7,22 11,34 20,86 10,43 16,30 38,86 13,62 25,73 60,64 15,31 32,16 87,43 19,08 44,53 138,93
Min Edge and Spacing
Nominal Embedment
Edge (Ccr,V)
(mm) (Cmin Smin)
(mm)
160
80
40
100
200
90
50
12,00
120
240
110
60
22,29
160
320
125
80
34,86
200
400
180
100
50,29
225
450
220
120
81,43
260
520
280
150
All data is based on correct installation - see instructions No influence of edge and spacing Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C
61
60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600
Hole Hole Max diameter diameter Torque concrete fixture (mm)
(mm)
(Nm)
10
9
10
12
12
20
14
14
40
18
18
80
24
22
120
28
26
160
35
32
200
= Steel failure
chemical anchors
Vorpa CV.PE
Polyester chemical anchor
Concrete
Natural stone
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
technical data Design resistance of resin with various stud strenghts and rebar
= Steel failure
5.8 grade steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
hef failure
embedment depth 60 6.9 7.7
60
70 80 90 8.1 9.2 10.4 9.0 10.3 11.6 10.8 12.4 13.9 15.5 17.4 17.1 19.2
70
80
90
100 11.5 12.9 15.5 19.4 21.4 21.5
110 12.7 14.9 17.0 21.3 23.5 23.6 25.2
100
110
120 15.5 18.6 23.2 25.6 25.8 27.5 27.1 120
130 16.7 20.1 25.2 27.8 27.9 29.8 29.4 130
140 18.0 21.6 27.1 29.9 30.1 32.1 31.7 140
160 20.1 24.7 31.0 34.2 34.4 36.6 36.2 160
200 29.2 38.7 42.7 43.0 45.8 45.2 200
240
46.5 51.3 51.6 55.0 54.3 240
280
54.2 59.8 60.2 64.1 63.3 280
320
54.4 68.4 68.8 73.3 72.4 320
400
480
540
600
660
84.9 86.0 103.2 91.6 109.9 123.7 90.5 108.6 122.2 135.7 400 480 540 600 660
720
Fd,s design load
(mm)
(kN)
110 156 189 281 398 569 695 860
12.7 20.1 29.2 54.4 84.9 122.4 159.1 194.5
hef
Fd,s
720
8.8 grade steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
failure
embedment depth 60 6.9 7.7
60
70 80 90 8.1 9.2 10.4 9.0 10.3 11.6 10.8 12.4 13.9 15.5 17.4 17.1 19.2
70
80
90
100 11.5 12.9 15.5 19.4 21.4 21.5
110 12.7 14.2 17.0 21.3 23.5 23.6 25.2
100
110
120 13.8 15.5 18.6 23.2 25.6 25.8 27.5 27.1 120
130 15.0 16.7 20.1 25.2 27.8 27.9 29.8 29.4 130
140 16.1 18.0 21.6 27.1 29.9 30.1 32.1 31.7 140
160 18.4 20.6 24.7 31.0 34.2 34.4 36.6 36.2 160
200 19.5 25.8 30.9 38.7 42.7 43.0 45.8 45.2 200
240 37.1 46.5 51.3 51.6 55.0 54.3 240
280
54.2 59.8 60.2 64.1 63.3 280
320
61.9 68.4 68.8 73.3 72.4 320
400
480
540
600
660
85.5 86.0 103.2 91.6 109.9 123.7 90.5 108.6 122.2 135.7 400 480 540 600 660
720
design load
(mm)
(kN)
170 240 291 433 612 876 1069 1323
19.5 30.9 45.0 83.7 130.7 188.3 244.8 299.2
hef
Fd,s
720
10.9 grade steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
failure
embedment depth 60 6.9 7.7
60
70 80 90 8.1 9.2 10.4 9.0 10.3 11.6 10.8 12.4 13.9 15.5 17.4 17.1 19.2
70
80
90
100 11.5 12.9 15.5 19.4 21.4 21.5
110 12.7 14.2 17.0 21.3 23.5 23.6 25.2
100
110
120 13.8 15.5 18.6 23.2 25.6 25.8 27.5 27.1 120
130 15.0 16.7 20.1 25.2 27.8 27.9 29.8 29.4 130
140 16.1 18.0 21.6 27.1 29.9 30.1 32.1 31.7 140
160 18.4 20.6 24.7 31.0 34.2 34.4 36.6 36.2 160
200 25.8 30.9 38.7 42.7 43.0 45.8 45,2 200
240 37.1 46.5 51.3 51.6 55.0 54.3 240
280
54.2 59.8 60.2 64.1 63.3 280
320
61.9 68.4 68.8 73.3 72.4 320
400
480
540
600
660
85.5 86.0 103.2 91.6 109.9 123.7 90.5 108.6 122.2 135.7 400 480 540 600 660
720
design load
(mm)
(kN)
236 334 405 603 852 1220 1489 1842
27.2 43.1 62.6 116.6 182.0 262.2 341.0 416.7
hef
Fd,s
720
A4-70 grade steel studding Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 24 27 30
10 12 14 18 24 28 32 35
depth mm
failure
embedment depth 60 6.9 7.7
60
70 80 90 8.1 9.2 10.4 9.0 10.3 11.6 10.8 12.4 13.9 15.5 17.4 17.1 19.2
70
80
90
100 11.5 12.9 15.5 19.4 21.4 21.5
100
110 12.7 14.2 17.0 21.3 23.5 23.6 25.2 110
120 13.7 15.5 18.6 23.2 25.6 25.8 27.5 27.1 120
130 16.7 20.1 25.2 27.2 27.9 29.8 29.4 130
140 18.0 21.6 27.1 29.9 30.1 32.1 31.7 140
160 20.6 24.7 31.0 34.2 34.4 36.6 36.2 160
200 21.7 30.9 38.7 42.7 43.0 45.8 45.2 200
*1 = tensile strenght 500N/mm2
62
240 31.6 46.5 51.3 51.6 55.0 54.3 240
280
54.2 59.8 60.2 64.1 63.3 280
320
58.8 68.4 68.8 73.3 72.4 320
400
480
540
85.5 86.0 103.2 80.2 90.5 98.1 400 480 540
600
600
660
660
720
1 1 720
design load
(mm)
(kN)
119 169 204 304 429 615 350 434
13.7 21.7 31.6 58.8 91.7 132.1 80.2 98.1
chemical anchors
Vorpa CV.PE
Polyester chemical anchor
Concrete
Natural stone
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
technical data Design resistance of resin with various stud strenghts and rebar
Rottura acciaio
Ferri da ripresa Fyk = 500 N/mm2 Ø
Ø
Stud diameter
Hole diameter
(mm)
(mm)
8 10 12 16 20 25 28 32
10 12 15 20 25 30 35 40
depth mm
hef 60 6.1 7.3
60
70 7.1 8.5 9.1
70
80 8.1 9.7 10.4 12.7 13.6
90 9.1 10.9 11.7 14.3 15.3
100 10.1 12.1 13.0 15.9 17.0 17.8
110 11.1 13.3 14.3 17.5 18.7 19.5 20.6
120 12.2 14.6 15.6 19.1 20.4 21.3 22.5
80
90
100
110
120
130 13.2 15.8 16.9 20.7 22.1 23.1 24.4 25.5 130
140 14.2 17.0 18.2 22.3 23.8 24.9 26.2 27.4 140
160 16.2 19.4 20.8 25.5 27.1 28.4 30.0 31.4 160
200
240
24.3 25.9 31.9 33.9 35.5 37.5 39.2 200
31.1 38.2 40.7 42.6 45.0 47.1 240
Fd,s
failure
embedment depth 280
44.6 47.4 49.7 52.5 54.9 280
320
51.0 54.3 56.8 60.0 62.7 320
400
500
560
640
720
67.9 71.0 88.8 75.0 93.7 104.9 78.4 98.0 109.8 125.5 400 500 560 640 720
800
design load
(mm)
(kN)
216 281 379 549 805 1107 1429 1783
21.9 34.1 49.2 87.4 136.6 196.5 267.8 349.7
800
technical data Characteristic and Design Load resistances based on characteristic bond strengths for hef 4d (minimum embedment) to 20d - threaded mod Non Cracked Concrete Characteristic Resistance (kN) Ø mm
8
10
12
16
20
24
30
Tension (Nrk) 14,85 19,80 39,60 16,57 24,85 55,22 21,82 34,29 74,82 31,54 49,28 126,17 41,20 77,82 183,10 46,31 97,26 222,30 57,70 134,66 288,56
Shear (Vrk)
9,00
15,00
21,00
39,00
61,00
88,00
142,50
Cracked Concrete
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
6,87 9,17 18,33 7,67 11,50 25,56 10,10 15,88 34,64 14,60 22,81 58,41 19,07 36,03 84,77 21,44 45,03 102,92 26,71 62,34 133,59
Shear (Vrd)
7,20
12,00
16,80
31,20
48,80
70,40
114,00
4,91 6,55 13,10 5,48 8,22 18,26 7,22 11,34 24,74 10,43 16,30 41,72 13,62 25,73 60,55 15,31 32,16 73,51 19,08 44,53 95,42
Shear (Vrec)
Characteristic Resistance (kN) Tension (Nrk)
Shear (Vrk)
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
Shear (Vrd)
Shear (Vrec)
5,14
Not applicable
Not applicable
Not applicable
8,57
Not applicable
Not applicable
Not applicable
12,00
Not applicable
Not applicable
Not applicable
22,29
Not applicable
Not applicable
Not applicable
34,86
Not applicable
Not applicable
Not applicable
50,29
Not applicable
Not applicable
Not applicable
81,43
Not applicable
Not applicable
Not applicable
Nominal Embedment (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600
All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C
63
chemical anchors
Vorpa CV.PE
Polyester chemical anchor
Concrete
Natural stone
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
technical data Characteristic and Design Load resistances for REBAR based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non Cracked Concrete Characteristic Resistance (kN) Ø mm
8
10
12
16
20
25
28
32
Tension (Nrk)
Shear (Vrk)
12,87 17,16 34,33 15,40 23,10 51,38 19,20 30,18 65,86 26,98 42,15 107,90 31,20 58,93 138,68 37,56 78,87 187,78 44,82 112,06 224,11 52,32 130,79 261,58
13.95
21,45
31,05
55,50
86,55
135,00
168,75
220,95
Cracked Concrete
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
Shear (Vrd)
6,13 8,17 16,35 7,33 11,00 24,47 9,14 14,37 31,36 12,85 20,07 51,38 14,86 28,06 66,04 17,89 37,56 89,42 21,34 53,36 106,72 24,91 62,28 124,56
9,30
14,30
20,70
37,00
57,70
90,00
112,50
147,30
4,38 5,84 11,68 5,24 7,86 17,48 6,53 10,27 22,40 9,18 14,34 36,70 10,61 20,04 47,17 12,78 26,83 63,87 15,24 38,12 76,23 17,80 44,49 88,97
Characteristic Resistance (kN)
Shear (Vrec)
Tension (Nrk)
Shear (Vrk)
Design Resistance (kN)
Recommended Load (kN)
Tension (Nrd)
Tension (Nrec)
Shear (Vrd)
Shear (Vrec)
6,64 Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
10,21
14,79
26,43
41,21
64,29
80,36
105,22
Nominal Embedment (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 500 112 280 560 128 320 640
All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C
Bond Strength Factors - Threaded mod Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) non cracked fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.97
1.00
1.02
1.04
1.07
1.10
1.12
1.15
Influence of environmental conditions in non cracked concrete
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
M8
M10
M12
M16
M20
M24
M30
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.90
0.88
0.87
0.86
0.85
0.84
0.82
Bond Strength Factors - REBAR Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) non cracked fc=
C15/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
0.97
1.00
1.02
1.04
1.07
1.10
1.12
1.15
Influence of environmental conditions in non cracked concrete
Temp I 40°C/24°C Temp II 80°C/50°C
Dry and Wet Dry and Wet
Ø8
Ø 10
Ø 12
Ø 16
Ø 20
Ø 25
Ø 28
Ø 32
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.90
0.90
0.88
0.88
0.86
0.86
0.84
0.84
64
chemical anchors
Vorpa CV.PE
Polyester chemical anchor
Concrete
Natural stone
Solid brick
Marble
Hollow brick
Perforated brick
Perforated cement
technical data Effect of anchor spacing - Tension Anchor spacing (mm) 40 50 60 70 80 90 100 120 150 160 175 200 225 240 250 275 280 300 320 350 400 425 450 480 520
Effect of edge distance - Tension
Stud/Rebar diameter 8 0,64 0,67 0,70 0,73 0,76 0,79 0,82 0,87 0,96 1,00
10 0,63 0,65 0,67 0,69 0,72 0,74 0,79 0,86 0,88 0,92 1,00
12
0,63 0,64 0,66 0,68 0,70 0,74 0,80 0,82 0,85 0,90 0,95 1,00
16
0,63 0,64 0,65 0,68 0,73 0,74 0,76 0,80 0,84 0,86 0,87 0,91 0,92 0,95 1,00
20
0,63 0,65 0,68 0,70 0,71 0,74 0,77 0,79 0,80 0,83 0,84 0,86 0,88 0,92 1,00
24
0,63 0,65 0,66 0,68 0,71 0,74 0,76 0,77 0,80 0,80 0,82 0,85 0,88 0,94 0,97 1,00
30
0,63 0,64 0,65 0,68 0,70 0,72 0,73 0,75 0,76 0,78 0,80 0,83 0,88 0,90 0,93 0,96 1,00
Edge distance (mm) 40 50 60 70 80 90 100 110 120 140 160 180 200 225 250 260
Effect of edge distance - Shear
Stud/Rebar diameter 8 0,64 0,73 0,82 0,90 1,00
10 0,63 0,70 0,77 0,84 0,91 1,00
12
0,63 0,68 0,74 0,80 0,86 0,92 1,00
65
16
0,63 0,67 0,71 0,76 0,80 0,89 1,00
20
0,63 0,66 0,70 0,77 0,84 0,91 1,00
24
0,64 0,68 0,76 0,84 0,92 1,00
30
0,63 0,66 0,72 0,78 0,86 0,94 1,00
Edge distance (mm) 40 50 60 70 80 90 100 110 125 140 160 180 200 225 250 280
Stud/Rebar diameter 8 0,25 0,44 0,63 0,81 1,00
10 0,30 0,48 0,65 0,83 1,00
12
0,30 0,44 0,58 0,72 0,86 1,00
16
20
24
0,40 0,53 0,67 0,35 0,80 0,44 1,00 0,58 0,35 0,72 0,45 0,91 0,58 1,00 0,71 0,84 1,00
30
0,30 0,36 0,47 0,59 0,74 0,88 1,00
chemical anchors
Vorpa CV MULTISET PLUS Polyester styrene free pourable resin
Concrete
Natural stone
Solid brick
Marble
products group Suitable • concrete • natural stone • solid brick • marble
CV MULTISET PLUS 5 kg. container unit
CV MULTISET PLUS 1 kg. container unit
To fix • anchoring threaded steel bolts into solid surfaces, typically cementitious surfaces • bedding-in coping stones, concrete units, steel, concrete or wooden posts. • repairs to large cracks in concrete surfaces requiring a self-levelling characteristic or difficult to reach areas. • traffic signs • crash-noise barriers on the road • bus shelters
product information Characteristics • Multiset Plus is a two component polyester mortar to fix threaded rod or rebar in a concrete floor, stone or plain brick. As a liquid product it can also be used to fill cracks. Ideal to fix playground equipment and bus shelters, traffic signs, crash and noise barriers on the road. Benefits • Fixing of rods or rebars in solid and hollow supports • Useful to fill cavities, cracks or difficult access areas • High solid content • Easy to apply • Slight contraction • High mechanical and physical resistance
Suggestion for use • Remove water and dirt (dust and loose material) with a circular brush and a blower or with air pressure. • Prepare the mixture of Multiset Plus with base and hardener. • Mix both components thoroughly to reach a homogeneous mixture (if necessary, use a drill with a mixer). • The items to be fastened must be clean. • Spill the product from the base of the hole until 2/3 full. • Insert the element to be fastened rotating, if necessary, keep the position with a suitable device. • Wait the recommended working and drying times. Before injection, verify the expiry date of the product, the support resistance and the ambient temperature. Setting and any subsequent adjustment are only possible during working time. In unopened original packaging, one year from manufacturing date. Store the product in a ventilated place away from direct exposure to sunlight. Keep between 5ºC and 25ºC.
66
chemical anchors
Vorpa CV MULTISET PLUS Polyester styrene free pourable resin
Concrete
Natural stone
Solid brick
Marble
B
installation sequence
A
A
B
A
A
technical data Code
Description
1175 1174
content kg
content box
5 1
base + hardener base + hardener
CV. MULTISET PLUS KG CV. MULTISET PLUS KG
Physical properties • Nature: unsaturated polyester resin • Colour: grey • Specific weight: 1,65 kg/l at 20ºC • VOC: 6,0 g/l Mixing Application
Working and hardening times Base material temperature (C°) Working time (min) Loading time (min)
5 55 240
20 18 120
10 40 180
25 12 90
30 8 60
35 6 50
Performance data for rods into concrete Anchor Rod Class 5.8
Installation
Resistance
Admissible loads
Drill diameter d0
Embedment depth hef
Standard edge distance Ccr
Standard anchor distance Scr
Torque moment Tinst
Characteristics resistance NRk
Concrete C20/25
Concrete C20/25
[mm]
[mm]
[mm]
[mm]
[N.m]
Tensile [kN]
Tensile [kN]
Shear [kN]
14 18 24 28
110 140 180 220
110 140 180 440
220 280 360 220
40 60 100 150
22,7 38,5 61,9 90,7
7,6 12,8 20,6 30,2
13,4 24,9 39,2 52,3
M12 M16 M20 M24
Safety factor for tension load 3,0
Performance data for rebar into concrete Bar diameter ds
Drill diameter d0
[mm]
[mm]
12
16
14
18
16
20
20
25
25
32
Ultimate load Fs in C20/25 concrete High adherence 500 MPa steel rebar Embedment depth Tension load
10 ds [mm] [kN]
20 ds [mm] [kN]
30 ds [mm] [kN]
40 ds [mm] [kN]
50 ds [mm] [kN]
Lv Fs [C20/25] Lv Fs [C20/25] Lv Fs [C20/25] Lv Fs [C20/25] Lv Fs [C20/25]
120 7,6 140 10,0 160 12,7 200 19,9 250 31,8
240 15,3 280 20,0 320 25,4 400 39,7 500 63,6
360 22,9 420 30,0 480 38,1 600 59,6 750 95,4
480 30,6 560 40,1 640 50,9 800 79,5 1000 127,2
600 38,2 700 50,2 659 63,7 1000 99,6 1250 159,0
Mechanical characteristics CV MULTISET PLUS Tensile strength Tensile modulus Compressive strength Compressive strength Flexural strength Flexural modulus
Units
Standard
Average value
[N/mm2] [N/mm2] [N/mm2] [N/mm2] [N/mm2] [N/mm2]
ASTM D638 ASTM D638 ASTM D695 EN 196-1 ASTM D790 ASTM D790
11,6 5045 76 76 21 1402
67
chemical anchors
Vorpa Bitumphalte 130 Bituminous adhesive bond
Road floors Asphalt
Metals
Cement
product group Suitable • road floors • asphalt • cement • metals
To fix • road marker, “cat’s eyes” • lane dividers, plastic cones • rubber on pavement
BITUMPHALTE 130 4,5 Kg steel can Examples of application
product information Characteristics • bituminous adhesive bond for the application of rubber and semi-rigid PVC to concrete, asphalt and metal Chemical composition • Bitumen, special solvent for quick drying, inert fillers selected resins, fibers, plasticizers, additives Suggestion • Any adjustment of the product is possible only before the drying
Use • It is important surfaces to be treated being completely dry, clean and free from oil and dust flour or other. It’s ready to be used and should be applied with a spatula. Drying times vary depending on the type of support, the layer thickness realized and the ambient temperature. Given to the high thixotropy, the application of the product is easy both horizontally and vertically. Tools, clothing and dirty hands can be cleaned with common synthetic thinners or nitro
installation sequence
technical data Code
1177
Description
BITUMPHALTE 130
Product Features content kg
content box
4,5
bituminous adhesive bond
Shelf life 24 months in original closed cup
BITUMPHALTE 130
Colour Characteristic Specific weight 20°C Dry residue at 130°C Viscosity brookfield (GIR. n°7 - 10 rpm)
68
standard
average value
EN ISO 2811-1 EN ISO 3251
black tixotropic resin 1,10 kg/l/-0,003 73%-81%
25°C
850P/-150
chemical anchors
Vorpa ROOF AND GUTTER SEALANT
Bitumen based mastic providing an effective seal between all roofing materials products group Limitations • do not use on glass • do not use on PVC • do not use internally
Areas for use • fills and seals gaps/cracks in most roofing applications • bonds to: concrete, roofing felt, lead, zinc, steel and masonry • for bedding tiles, slates and flashing into position • joint sealing on gutters and down pipes • sticking down loose roofing felt • joint sealing between corrugated asbestos cement and iron sheeting etc.
product information Benefits • Incorporates polymer additives to improve adhesion • Can be applied in wet conditions, even under heavy rain • Semi drying - remains permanently elastic beneath surface skin • High solids formulation - excellent gap filling properties without shrinkage • Excellent external weathering properties • Form ready to use thixotropic paste, black in colour • Elastoplastic sealant adhesive based on bituminous elastomeric resins which adhere on most common building materials, even on wet surfaces, forming a flexible film • For bonding and sealing of roofs, insulation materials (excluded expanded PS), ceramic tiles, roofing tiles, polymeric surfaces (plastics) free of plasticizers. To seal and waterproof joints, cracks, various breakings, car body shells, etc. Adheres on concrete, zinc, wood, aluminium, metal sheet, etc. Good occasional resistance to solvents, except turpentine and mineral oils. Not overpaintable, not compatible with other sealants
Benefits • Color black • Specific weight ca. 1,02 g/cm3 • Viscosity fixotropic paste • Boiling point 150 °C • Flash point > 39 °C • Application temperature 5 ÷ 30 °C • Open time < 20 min. • Temperature resistance -35 ÷ 110 °C • Strain absent Surface preparation • Surfaces must be sound, clean and dry, free of oil and other contaminants. Apply with sealant gun in curbs. Complete curing depends on width and atmospheric conditions and may take from 12 hours to 2 days. Anyway, after some hours a good adhesion and consistence are obtained. Tools can be cleaned with mineral turpentine. Consumption as adhesive: ca. 310 ml/mq Consumption as sealant (0,5 x 0,5) cm: ca. 10 meters
application
Code
2300
Description
VORPA BITUM
Content ml
Gun to be used
310
silicone
69
chemical anchors
Vorpa Battery tool 14.4V Extrusion tools for chemical anchors products information Battery tool 14.4 V for chemical anchors co-axial up to 410ml
Weight • Cordless caulking gun: 2.40 Kg • Case including caulking gun and charger: 5.8 Kg
Main features • Trigger with speed control. Maximum extrusion rate 0-4,5 mm/s. • Extrusion power 550 Kgf. • Anti-dripping. Applications • Suitable for 410ml 10:1 co-axial cartridges. • Continuous and clean work. • Easy to carry thank to the apposite case containing extra battery pack and battery charger. • Li-ion battery with low self-discharge rate, no memory effect, long life, light weight. • LED auxiliary light. • Voltage characteristics: 14.4V 1.5AH 220V/230V.
Vorpa EASY PRESS 14,4V 380/410 COAX Cordless sealing gun Easy Press 14,4 V Li-Ion for chemical anchors co-axial cartridges up to 410 ml
Vorpa EASY PRESS 14,4V SPARE PARTS 14,4V extra battery Li-Ion pack
Code
9109
Code
9110
Performances • Each charge of battery can plunge up to 45 tubes of 410ml chemical anchor cartridge. • Durable battery life for 500 charge-discharge cycles. Kit Case Content • n°1 Easy Press 14.4V • n°2 Li-ion Battery Packs 14.4V • 14.4V Battery Charger • Blow mould plastic case
Description
Description
• Suitable for: CV.VSF 400 CE - CV.PSF 410 - CV.PE 410 CV.ESF 410 • Kit case content: n° 1 Easy Press 14,4V 410 Coax n° 2 Battery packs n° 1 Battery charger
Easy Press 14.4V 380/410 ml coax 550 Kgf thrust 10:1 co-axial cartridges weight kg 2,4
Description
Li-Ion extra charger
Vorpa EASY PRESS 14,4V SPARE PARTS 14,4V Li-Ion extra charger
70
Code
9111
Description
14,4 charger
chemical anchors
Vorpa CVB - CVD
steel internal threaded sleeves for concrete masonry and hollow bricks technical data
CVD steel internal threaded sleeve
CVB steel internal and external threaded sleeve
technical data Steel sleeve CVD Code
1236 1237 1238
Steel sleeve CVB Description
d0 mm
Lt mm
Lf mm
h1 mm
hef mm
db mm
CV D 12x80 CV D 14x80 CV D 16x80
14 16 18
80 80 80
55 55 55
90 90 90
80 M8 80 M10 80 M12
Code
1036 1037 1038 1039
Description
d0 mm
Lt mm
Lf mm
h1 mm
hef mm
db mm
M mm
CV B 12x80 CV B 12x80 CV B 16x80 CV B 16x80
14 14 18 18
80 80 80 80
32 32 32 32
90 90 90 90
80 M6 M14 80 M8 M14 80 M10 M16 80 M12 M16
Usable for application on hollow brick with plastic sleeves and solid brick. Lf
LTffix
Tfix
Lf
M db
d0
db
Øb
d0
Lt h1
db
d0
db
Øb
Lt
Lt h1
hef
= Anchor length = Stud length = Hole diameter = Internal sleeve thread = Min. hole depth
installation sequence hollow brick
solid brick
Performance based on clean holes.
71
Stud length calculation: Lb = Lt +Tfix Lt = Anchor length Tfix = Fixture thickness
Lt h1
hef
hef = Effective anchorage depth Øb = Stud diameter Tfix = Fixture thickness Lf = Internal thread length M = External sleave thread
Tfix
M
d0
h1 hef
Lt Lb d0 db h1
Øb
LTffix
hef
Øb
chemical anchors
Vorpa asphalt anchor system CV F Steel threaded sleeve for anchor stud on asphalt surfaces
Asphalt
Product group Characteristics Asphalt anchor system to be used with chemical anchors Easy and safe solution on asphalt and various base material surfaces Benefits High performances. Fixture can be removed and replaced. No expansion stress in the base material. Versatile and flexible To fix Road signs, parking protection, bollards, fencing, shelters Edge protections, playgrounds, speed bumps
Examples of applications
Installation sequence
Technical data Code
Description
52190 52191 52192 52193
CVF 12x70 CVF 12x100 CVF 14x70 CVF 14x100
Pull out failure
Anchor length 70 mm Anchor length 100 mm
Fi mm
d0 mm
Lt mm
h1 mm
M 10x20 M 10x20 M 12x20 M 12x25
14 14 16 16
70 100 70 100
75 105 75 105
h1 Lt d0 Lt d0 Fi h1
Tension
10 kN 18 kN * 1kN â&#x2030;&#x192; 100 Kg
72
= Anchor length = Hole diameter = Internal thread = Minimum hole length
chemical anchors
Vorpa CLOU PERFORATED SLEEVE Safe fixing on hollow materials to be used with chemical anchor
Hollow brick
Perforated brick
Perforated cement
products group Examples of application
technical data
Code
2903
Description
d0 mm
db mm
Lt mm
h1 mm
CLOU 10x145
10
8
145
150
technical data Permissable loads in daN Clou Hollow brick Perforated brick Perforated cement
daN daN daN
315 415 500
8 x 12 holes
installation sequence
Lt = Hole diameter d0 = Anchor length
8 x 10 holes
db = Sleeve internal diameter h1 = Min. hole depth
SOCOTEC Specification report EAD 6802/1
73
chemical anchors
Vorpa CVA
plastic perforated sleeve for hollow bricks technical data
Usable for application on hollow brick with M8-M14 studs
technical data
Code
914 1914
Description
d0 mm
Lt mm
h1 mm
hef mm
Ă&#x2DC;b mm
CV A 13x100 CV A 15x100
14 16
100 100
110 110
100 100
M8-M12 M8-M14
hef
Tfix
h1
db
db
d0
Lt Lb
Lt = Anchor length Lb = Stud length d0 = Hole diameter db = Internal sleeve thread h1 = Min. hole depth hef = Effective anchorage depth Ă&#x2DC;b = Stud diameter Tfix = Fixture thickness Stud length calculation: Lb = Lt +Tfix Lt = Anchor length Tfix = Fixture thickness
installation sequence
74
chemical anchors
Vorpa CVH
steel perforated sleeve for hollow bricks with bent end technical data
CVH
technical data
Code
2912 2913 2914
Description
CV H 15 x 85 CV H 15 x 130 CV H 17 x 130
d0 mm
h1 mm
15 15 17
90 140 130
do mm
Lt mm
Øb mm
85 130 130
M8-M10 M8-M10 M10-M14
Tfix
h1
db
Øb
d0
Lt Lb
Lt = Anchor length Lb = Stud length d0 = Hole diameter db = Internal sleeve thread h1 = Min. hole depth hef = Effective anchorage depth Øb = Stud diameter Tfix = Fixture thickness Stud length calculation: Lb = Lt +Tfix Lt = Anchor length Tfix = Fixture thickness
installation sequence
Performance based on clean holes.
75
chemical anchors
Vorpa CV K
steel perforated sleeve for hollow bricks adustable in depth with sheet metal shears technical data
CV K
technical data
Code
2900 2901 2902
Description
d0 mm
db mm
Lt mm
Øb mm
CV K 12/1000 CV K 16/1000 CV K 22/1000
12 16 22
9,5 12,5 18,5
1000 1000 1000
M8 M10-M12 M12-M16
Tfix
h1
db
Øb
d0
Lt Lb
Lt = Anchor length Lb = Stud length d0 = Hole diameter db = Internal sleeve thread h1 = Min. hole depth hef = Effective anchorage depth Øb = Stud diameter Tfix = Fixture thickness Stud length calculation: Lb = Lt +Tfix Lt = Anchor length Tfix = Fixture thickness
installation sequence
Performance based on clean holes. 76
chemical anchors
Vorpa CV X
plastic perforated sleeve for hollow bricks technical data plastic perforated sleeve for hollow bricks
technical data
Code
1006 1006E 51006 913 1017 915
Description
CV X 12 X 50 CV X 12 X 60 CV X 12 X 80 CV X 16 X 85 CV X 16 X 130 CV X 20 X 85
d0 mm
Lt mm
h1 mm
hef mm
Øb mm
12 12 12 16 16 20
50 60 80 80 130 85
60 70 90 90 140 95
50 60 80 80 130 85
fino a 8 fino a 8 fino a 8 8 - 12 8 - 12 12 - 16
hef
Tfix
h1
db
Øb
d0
Lt Lb
Lt = Anchor length Lb = Stud length d0 = Hole diameter db = Internal sleeve thread h1 = Min. hole depth hef = Effective anchorage depth Øb = Stud diameter Tfix = Fixture thickness Stud length calculation: Lb = Lt +Tfix Lt = Anchor length Tfix = Fixture thickness
installation sequence hollow brick
Performance based on clean holes. 77
chemical anchors
Vorpa CVX
plastic perforated sleeve for hollow bricks adustable in depth technical data
CVX
technical data
Code
Description
d0 mm
h1 mm
h2 mm
hef mm
Lt mm
Øb mm
Tfix min mm
Tfix max mm
51017
CVX 16x330
18
135
340
130
330
M10-M12
20
200
h2 h1 Tfix
d0
Øb
hef Lt
Lt = Anchor length d0 = Hole diameter h1 = Min. hole depth h2 = Max hole depth hef = Effective anchorage depth Øb = Stud diameter Tfix = Fixture thickness
installation sequence
Tinst=4Nm
Tfix
Performance based on clean holes. 78
chemical anchors
Vorpa ACCESSORIES Fixing accessories products group • Ideal for various applications • the bars can be cut to size • Available also with nut and washer
• Suitable on compact materials with CVB-CVD metal sleeves • Suitable on hollow materials with CVX-CVA-CVH plastic sleeves
• Suitable for each applications with chemical anchors and mechanical anchors
Installation sequence Example of applications for threaded bars with chemical anchors and plastic/metal sleeves
Application on compact material for CVB metal sleeve
Application on compact material for CVD metal sleeve
Application on hollow material for CVX plastic sleeve
Application on hollow material for CVK metal sleeve
Application on hollow material for CVA plastic sleeve
Example of applications for threaded bars with chemical resin capsules
Installation sequence on compact base material VF CE resin capsule
Installation sequence on compact base material VFP resin capsule
technical data
5.8
S VFA INOX A4 A4 stainless steel anchor stud VFA hexagonal head with nut and washer. Code
Description
51920 51921 51922 51924 51926 51928
VFA A4 M8 x 110 VFA A4 M10 x 130 VFA A4 M12 x 160 VFA A4 M16 x 190 VFA A4 M20 x 260 VFA A4 M24 x 300
* *
hexagons thread S
thread
stud length
hole Ø
5 7 8 12 14 14
M8 M10 M12 M16 M20 M24
110 130 160 190 260 300
10 12 14 18 24 28
VFM 5.8 steel anchor stud VFM hexagonal head with nut and washer. Code
2920 2921 2922 2924 2925 2926 2956
One driver tool in each box
Condition of ETA validity: use the threaded bars together with VORPA VF CE Resin capsules
Description
VFM M8 x 110 VFM M10 x 130 VFM M12 x 160 VFM M16 x 190 VFM M20 x 260 VFM M24 x 300 VFM M30 x 380
* * 79
hexagons thread S
thread
stud length
hole Ø
80 90 110 125 170 210 275
M8 M10 M12 M16 M20 M24 M30
110 130 160 190 260 300 380
10 12 14 18 22 26 32
One driver tool in each box
Condition of ETA validity: use the threaded bars together with VORPA VF CE Resin capsules
chemical anchors
Vorpa ACCESSORIES Fixing accessories technical data
8.8 VFG steel anchor stud VFG with nut and washer Code
922 924 926 928 956
VFG 8.8 8.8 steel anchor stud VHA with nut and washer
Description
thread
stud length
hole Ø
VFG M12 x 160 VFG M16 x 190 VFG M20 x 260 VFG M24 x 300 VFG M30 x 380
M12 M16 M20 M24 M30
160 190 260 300 380
14 18 24 28 40
Code
9922 9924 9926 9928 9956
Description
thread
stud length
hole Ø
VFG 8.8 M12 x 160 VFG 8.8 M16 x 190 VFG 8.8 M20 x 260 VFG 8.8 M24 x 300 VFG 8.8 M30 x 380
M12 M16 M20 M24 M30
160 190 260 300 380
14 18 24 28 40
*
ZINCATO CALDO
One driver tool in each box
HOT DIP COATING
*
VFG ZC hot dipped galvanized steel anchor stud VFG with nut and washer Code
Description
thread
stud length
hole Ø
58025 58026 58027 58028 58029 58030
VFG ZC M10 x 130 VFG ZC M12 x 160 VFG ZC M16 x 190 VFG ZC M20 x 260 VFG ZC M24 x 300 VFG ZC M30 x 360
M10 M12 M16 M20 M24 M30
130 160 190 260 300 360
12 14 18 24 28 40
CVM steel anchor stud CVM with nut and washer Code
911 916 912 917 918 919
Condition of ETA validity: use the threaded bars together with VORPA VF CE Resin capsules
S
DRIVER TOOL
Description
thread
stud length
hole Ø
CVM 8 x 75 CVM 8 x 100 CVM 10 x 95 CVM 10 x 110 CVM 10 x 140 CVM 12 x 115
M8 M8 M10 M10 M10 M12
75 100 95 110 140 115
10 10 12 12 12 14
Code
945 946 947A 949 951 953 954 955
80
Description
Internal thread S min
Ø tang mm
VFG M 8 VFG M 10 VFG M 12 VFG M 16 VFG M 20 VFG M 24 VFG M 27 VFG M 30
M8 M10 M12 M16 M20 M24 M27 M30
8 10 10 13 13 13 13 13
chemical anchors
Vorpa ACCESSORIES Fixing accessories technical data
4.8 DIN 975
4.8 threaded bar cm 100 Code
1020 1021 1022 1023 1026 1024 1027 1025 1034 1035 1052 1053
Description
M 6x1000 M 8x1000 M 10x1000 M 12x1000 M 14x1000 M 16x1000 M 18x1000 M 20x1000 M 22x1000 M 24x1000 M 27x1000 M 30x1000
8.8
thread
M 6 M 8 M 10 M 12 M 14 M 16 M 18 M 20 M 22 M 24 M 27 M 30
stud length
hole Ø
100 100 100 100 100 100 100 100 100 100 100 100
8 10 12 14 16 18 22 24 26 28 32 40
8.8 threaded bar cm 100 Code
Description
90462 90463 90464 90490 90485 90484 90488 90489
M 8x1000 M 10x1000 M 12x1000 M 14x1000 M 16x1000 M 20x1000 M 24x1000 M 27x1000
DIN 975 thread
M 8 M 10 M 12 M 14 M 16 M 20 M 24 M 27
stud length
hole Ø
100 100 100 100 100 100 100 100
10 12 14 16 18 24 28 32
4.8 4.8 threaded bar cm 300 Code
Description
50167 50173 50174 50175 50055
M 6x3000 M 8x3000 M 10x3000 M 12x3000 M 16x3000
A2 stainless steel threaded bar cm 100
DIN 975 thread
M 6 M 8 M 10 M 12 M 16
stud length
hole Ø
300 300 300 300 300
8 10 12 14 18
Code
4060 4061 4062 4063 4065
Description
M 6x1000 M 8x1000 M 10x1000 M 12x1000 M 16x1000
A4 stainless steel on request
81
thread
M 6 M 8 M 10 M 12 M 16
DIN 975 stud length
hole Ø
100 100 100 100 100
8 10 12 14 18
chemical anchors
Vorpa VF CE RESIN CAPSULES
Vinylester resin capsule with ETA option 7 for non-cracked concrete “spin-in” type
Non-cracked Concrete
products group
VF CE RESIN CAPSULE
Suitable • non-cracked concrete
To fix • starter bar applications • threaded studs • crush barriers • machinery - cladding • steel columns • guardrails • noise protection walls • balustrades
European Technical Approval Option 7 for non-cracked concrete
Software Vorpa Calcul Anchor
product information Characteristics • Chemical anchors VF CE consist of a capsule containing a blend of resin, quarts, sand and special hardener encapsulated in a small glass capsule. The capsule is placed into a drilled hole previously cleaned and threaded rod is driven by machine with turning (simultaneous hammering and turning).
Suggestions for use • Avoid direct sunlight. • Clean out hole thoroughly before application. • Anchors to be tightened with calibrated torque wrench. • See ETA for more details
Benefits • Capsules can be set in either direction. • Quick curing and gel time. • No waste of material. Safe and easy to use. • Chemical corrosion resistant. • Can be installed in wet concrete or in hole filled with water. • Product with ETA option 7 for non-cracked concrete. • Suitable for close edge applications, no tension on base material.
technical data Art.
5900 5901 5902 5904 5906 5908
Description
VF CE M 8 VF CE M 10 VF CE M 12 VF CE M 16 VF CE M 20 VF CE M 24
Length mm
Storage Shelf life
80 80 95 95 160 190
Store in cool and dry place between +5°C and + 25°C. Shelf life 24 months from the manufacture date.
82
chemical anchors
Vorpa VF CE RESIN CAPSULES
Vinylester resin capsule with ETA option 7 for non-cracked concrete “spin-in” type
Non-cracked Concrete
installation sequence Standard cleaning
X2
X2 Premium cleaning
X2 >6 BAR X2
X2 technical data Minimum curing time and working time Concrete temperature (C°)
Minimum curing time (dry concrete)
Minimum curing time (wet concrete)
-5° - 0 0-5 5 - 10 10 - 20 > 20
360 180 90 40 20
720 360 180 80 40
Specification data
Hole diameter Hole diameter in fixture Minimum hole depth Minimum slab thickness Torque moment Minimum spacing Minimum edge distance
dO dfix hO hmin Tinst Smin Cmin
mm mm mm mm Nm mm mm
M8
M10
M12
M16
M20
M24
10 9 80 110 10 60 60
12 12 90 120 20 70 70
14 14 110 150 40 85 85
18 18 125 160 60 95 95
25 22 170 220 120 130 130
28 26 210 300 150 160 160
83
chemical anchors
Vorpa VF CE RESIN CAPSULES
Vinylester resin capsule with ETA option 7 for non-cracked concrete “spin-in” type
Non-cracked Concrete
technical data Performance data Threaded size Embedment depth Tension load Standard cleaning Characteristic resistance non cracked concrete C20/25 - (50/80°C) Design resistance ɤMC=1.8 Premium cleaning Characteristic resistance non cracked concrete C20/25 - (50/80°C) Design resistance ɤMC=1.8 Increasing factors C30/37 C40/50 C50/60 Shear load Steel Failure, Steel Grade 5.8 Characteristic resistance Design resistance ɤMs=1.3 Steel Failure, A4 - 70 Steel Grade Characteristic resistance Design resistance ɤMs=1.56 Bending Moment Steel Failure, Steel Grade 8.8 Characteristic resistance Design resistance ɤMs=1.3 Steel Failure, A4 - 70 Steel Grade Characteristic resistance Design resistance ɤMs=1.56
M8 M10 M12 M16 M20 M24 0.55 0.58 0.63 0.69 0.76 0.82 0.89 0.96 1.00
0.54 0.59 0.64 0.69 0.74 0.80 0.85 0.94 1.00
0.54 0.58 0.62 0.66 0.70 0.74 0.81 0.88 0.95 1.00
0.53 0.56 0.59 0.62 0.65 0.70 0.75 0.80 0.89 0.99 1.00
M10
M12
M16
M20
M24
hef
mm
80
90
110
125
170
210
NRk,P
kN
9
12
16
25
40
60
NRd,s
kN
5
6,6
8,8
13,8
22,2
33,3
NRk,P
kN
12
16
25
35
60
75
NRd,s
kN
6,6
8,8
13,8
19,4
33,3
41,6
ψc ψc ψc
1,08 1,15 1,19
VRk,c VRd,c
kN kN
8 6,2
13 10
19 14,6
36 27,6
57 43,8
83 63,8
VRk,c VRd,c
kN kN
11 7
17 10,8
26 16,6
49 31,4
77 49,3
111 71,2
MRk,s MRa,s
kN kN
16 12,3
30 23
56 43
144 110
285 219
498 383
MRk,s VRd,s
kN kN
22 14
41 26,2
75 48
194 124,3
384 246
670 429,4
Edge distance (shear)
Edge distance (tension load)
CN mm 40 45 55 65 75 85 95 105 120 135 150 175 200 225 250 275 300 335
M8
0.54 0.57 0.59 0.63 0.67 0.71 0.79 0.86 0.94 1.00
0.56 0.59 0.63 0.66 0.72 0.79 0.85 0.92 0.99 1.00
CV mm 40 50 60 70 80 90 100 120 140 160 180 200 220 260 320 360 405 450 490
M8 M10 M12 M16 M20 M24 0.36 0.45 0.54 0.63 0.72 0.81 0.90 1.08 1.26 1.44
0.38 0.46 0.54 0.62 0.69 0.77 0.92 1.08 1.23 1.38 1.54
0.37 0.44 0.50 0.56 0.62 0.75 0.87 1.00 1.12 1.25 1.37 1.62
84
0.35 0.40 0.44 0.49 0.59 0.69 0.79 0.89 0.99 1.09 1.28 1.58
0.37 0.41 0.49 0.57 0.66 0.74 0.82 0.90 1.07 1.31 1.48
0.43 0.50 0.58 0.65 0.72 0.79 0.94 1.15 1.30 1.46
Spacing
S mm 40 50 60 70 80 90 100 120 140 160 180 200 220 260 320 360 405 450 490 550 600 670
M8 M10 M12 M16 M20 M24 0.59 0.61 0.64 0.66 0.68 0.70 0.73 0.77 0.82 0.86 0.91 0.95 1.00
0.60 0.62 0.63 0.65 0.67 0.69 0.73 0.77 0.81 0.85 0.88 0.92 1.00
0.59 0.61 0.62 0.64 0.66 0.69 0.72 0.75 0.78 0.81 0.84 0.90 1.00
0.59 0.60 0.61 0.62 0.65 0.67 0.70 0.72 0.75 0.77 0.82 0.90 0.94 1.00
0.59 0.60 0.62 0.64 0.66 0.68 0.70 0.73 0.77 0.83 0.87 0.91 0.96 1.00
0.61 0.63 0.64 0.66 0.68 0.70 0.73 0.79 0.82 0.86 0.91 0.94 1.00
chemical anchors
Vorpa FOAMPLUS UNIVERSAL Self-expanding polyurethane foam products group To fix • Windows and doors frames • Pipes insulation • Fixing of Insulating panels • Do it yourself works • Electrical installations • Fillings and finishing touches
FOAMPLUS UNIVERSAL SPRAY TYPE
FOAMPLUS UNIVERSAL GUN TYPE product information Characteristics • Self-expanding one component polyurethane foam available in Spray and Gun types. • It expands and hardens with air humidity. Benefits • High adhesion to most of the building materials. • High filling capacity, up to 45lt. • After setting it can be treated mechanically. • Chemical agents, moulds and micro-organisms resistant. • CFC free propellent. Non harmful for users and ozone layer. • Waterproof. • Sound-proofing and heat insulation properties.
Instructions for use • Shake before using. • The surface of application must be well cleaned. Remove dust, oil and grease. • Surfaces must be moistened with water. • Apply upward. In presence of wide hollow materials it is suggested to repeat the application after setting. • The application can be interrupted in any moment, leave the bottle turned on the gun till completely empty. • Avoid any contact with sources of ignition, heat, flames.
application FOAMPLUS spray type
FOAMPLUS gun type
Stability load bearing (Ø12 mm joint)
technical data Code
3780 3781
Description
FOAMPLUS UNIVERSAL SPRAY TYPE FOAMPLUS UNIVERSAL GUN TYPE
Content ml
Extrusion
750 750
Spray For gun
Colour beige Content ml. 750 State liquefied gas in pressure content Specific weight (extruded) 25-30 kg/m3 Foam yeld / 1000 ml ca. 30 liters Skin formation time (23°C, 50% H.R.) 12-16 min. Can be cut (23°C, 50% H.R.) 30-40 min. Tensile strength (BS 5241) 11 N/cm2 Pressure strength (DIN 53421) 2 N/cm2
Thermal conductivity Temperature resistance Application temperature Flammable Class Storage
85
30 mW/m°K -50°C ÷ +90°C +5°C ÷ +30°C B3 (DIN 4102, 1st part) Cool and dry place. Vertical position, temperature below 30°C 12 months in original, unopened packing at cool and dry place
chemical anchors
Vorpa FOAMPLUS FOR ROOFING Self-expanding polyurethane foam products group To fix • Pipes insulation • Roofing tiles fixings • Fillings and finishing touches • Fixing of Insulating panels • Windows and doors frames • Chimney flues insulation
FOAMPLUS FOR ROOFING SPRAY TYPE
FOAMPLUS FOR ROOFING GUN TYPE product information Characteristics • Self-expanding one component polyurethane foam available in Spray and Gun types. • It expands and hardens with air humidity. Benefits • Suitable for repairing of roofing. • High adhesion to most of the building materials. • High filling capacity, up to 45lt. • After setting it can be treated mechanically. • Chemical agents, moulds and micro-organisms resistant. • CFC free propellent. Non harmful for users and ozone layer. • Polymerize at low temperatures.
Instructions for use • Shake before using. • The surface of application must be well cleaned. Remove dust, oil and grease. • Surfaces must be moistened with water. • Apply upward. In presence of wide hollow materials it is suggested to repeat the application after setting. • The application can be interrupted in any moment, leave the bottle turned on the gun till completely empty. • Avoid any contact with sources of ignition, heat, flames.
application FOAMPLUS spray type
FOAMPLUS gun type
Stability load bearing (Ø12 mm joint)
technical data Code
3788 3789
Description
FOAMPLUS FOR ROOFING SPRAY TYPE FOAMPLUS FOR ROOFING GUN TYPE
Content ml
Extrusion
750 750
Spray For gun
Colour grey Content ml. 750 State liquefied gas in pressure content Specific weight (extruded) 25-30 kg/m3 Foam yeld (extruded) > 40 % Skin formation time (23°C, 50% H.R.) 12-16 min. Can be cut (23°C, 50% H.R.) 30-40 min. Tensile strength (DIN 53455) > 100 KPa Pressure strength (DIN 53421) > 25 KPa Volume variation < 2 % Vol.
Thermal conductivity (DIN 52612) Acoustic Insulation (EN ISO 717-1) Temperature resistance Application temperature Flammable Class Storage
86
0,034 W/(m°K) 60 dB -40°C ÷ +90°C -10°C ÷ +35°C B3 (DIN 4102, 1st part) Cool and dry place. Vertical position, temperature below 30°C 12 months in original, unopened packing at cool and dry place
chemical anchors
Vorpa FOAMFAST 750
Self-expanding special adhesive for rapid installation of exterior insulation finishing EPS panels. products group
THERMIC
INSULATYION
5-6m2
For gun
SELF-EXTINGUISHING
2h
ENERGY SAVING
Output in square
product information Characteristics • Gun adhesive sticks to all common construction materials for filling and fixing gaps in exterior insulation finishing Benefits • The high output and powerful initial bond strength enable rapid, efficient panel mounting • The product is ready to use and requires no additional support structures • EIFS gun adhesive is used in place of mortar mixes • Particulary suitable for bonding insulating panels, adheres on most of the building materials (PS, PU, bituminous). Does not adhere on PP, PE, TEFLON and silicons. • Protect from direct sunlight exposure. Overpaintable • Installation yield: 5-6 sqm. • It is not subject to ageing, but is susceptible to UV radiation damage. Excellent thermal and sound insulation properties • Simple time-saving application • Powerful initial bonding • Low storage space requirement • Clean application • Construction material B2 according to DIN 4102
application
87
Instructions for use • Shake well before use. Apply fist on the edges of panels, then zig-zag spray on clean, dust- and greasefree surfaces using the specific gun, keeping the can upside down. (moistening surfaces improves adhesion, curing and structure). • Wait about 2 minutes before install and align panels within 5 minutes. • Delete possible big surfaces irregularity by applying mortar before placing panels. • In case of rain or wind, protect panels as it takes 2 hours for the adhesive to reach the appropriate mechanical properties. • In case of further applications (over 24 hours after) immediately clean the erogation valve (and the gun) by using Foam Dissolver.
chemical anchors
Vorpa FOAMFAST 750
Self-expanding special adhesive for rapid installation of exterior insulation finishing EPS panels. examples of application
technical data Code
3802
description
FOAMFAST FOR GUN
content ml
extrusion
pcs for box
750
For gun
12 pcs.
Content ml. 750 Status liquefied gas presure content Colour Yellow Specific weight (extruded) 25-30 kg/m3 Skin formation time (23°C, 50% H.R.) ca. 12 min. Shear strenght (depth 3 cm) ca. 40 min. Post expansion 5 % Shrinkage absent Tensile strenght (BS 5241) 11,1 N/cm2 Crush strenght (DIN 53421) 4 N/cm2 Thermal conductivity/20°C (DIN 52612) 0,03 W/(m°K) Acoustic insulation (EN ISO 717-1) 60 dB Temperature resistance -40 ÷ 90 °C Application temperature 5 ÷ 25 °C Flammable Class: (DIN 4102 - 1) B2 (EN 13501 - 1) E Storage The ideal storage temperature for canisters is between +10°C and +20°C. Canisters should be stored vertically, protected from heat and frost. 12 months in original, unopened packing at cool and dry place
88
Adhesive application on panels
Mechanical heavy duty anchors
through-setting heawy duty anchors
Vorpa VEX+SEISMIC Heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete
Cracked and non-cracked concrete
Product group Approved for • Cracked and non-cracked concrete M8-M27 • Reinforced and unreinforced normal weight concrete C20/25 - C50/60 • Anchorage under static, quasi/static actions M8-M27 • Seismic applications C1-C2 TR045 - M10 - M20 • Anchorage under fire exposure in standard TR 020 R30-R120
VEX+SEISMIC
VEX+SEISMIC (A4 Stainless Steel)
Also suitable for • Natural stone • Concrete C12/C15
European Technical Assesment ETAG 001 - PART 1 - 2 ANNEX E Option 1 - Cracked and non cracked concrete Seismic fixings - category C1-C2 annex E - TR045
R30-R120
Annex E -
Suitable to fix • Parapets • Steel beams • Machine tools • Industrial systems • Heavy duty metal constructions • Static, quasi/static anchorages • Structural fixings
As it can also be used on concrete with different strength characteristics, as specified in ETA, on compact natural stone and others materials (exception not included in ETA), specific on-site tests by the user are necessary
C1-C2
Product information Characteristics • Special wedge anchor assembled with hex nut and washer certified ETA-CE option1 and performance category C1-C2 under seismic action Benefit • Approved under the building regulations with a new European Technical Assessment (Option 1) • Approved for use in cracked and non-cracked concrete • Approved for use under seismic loading, performance categories C1 and C2 (M10 to M20, maximum anchor length 210 mm) • Suitable for use in compression resistant natural stone (without approval) • Two effective anchorage depths for greater flexibility (M8 to M16, maximum anchor length 210 mm) • Anchoring with the smaller effective anchorage depth reduces drilling and installation time. • Anchoring with the standard effective anchorage depth is suitable for the highest load limits
Benefit • Suitable for sprinkler system installations complying with VdS requirements • FM approval for the installation of sprinkler systems (M10 to M16) • Shock approval by the Swiss Federal office for Civil Protection Installation • Through-setting anchor Suggestion for use • Choose the most suitable accessory in relation to the application to carry out • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
• Suitable for surface, through, and stand-of fastening • Fire tested in compliance with DIN 4102-2. Fire resistance ratings R30–R120
90
through-setting heawy duty anchors
Vorpa VEX+SEISMIC Heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete
Cracked and non-cracked concrete
Installation sequence Installation instruction on concrete
Drill a hole into the concrete in rotary plus hammer mode
Remove the dust into the hole using a brush and a blowing pump
1)
Hammer the anchor into the hole
1)
Place the fixture
1) Through
fixing is allowed (place the fixture before placing the anchor)
Apply the required torque moment Tinst
Technical data VEX+SEISMIC zincplated
Code
**32101 **32102 **32103 **32104 32105 32106 32107 32108 32109 32110 32111 32112 32113 32114 32115 32116 32117 32118 32119 32120 32121 32122 32123 32124 32125
Description
Lt mm
hef/ hefrid mm
VEX+SEISMIC 8/6-60 VEX+SEISMIC 8/15-26-80 VEX+SEISMIC 8/30-41-95 VEX+SEISMIC 8/50-61-115 VEX+SEISMIC 10/10-30-90 VEX+SEISMIC 10/15-35-95 VEX+SEISMIC 10/20-40-100 VEX+SEISMIC 10/30-50-110 VEX+SEISMIC 10/50-70-130 VEX+SEISMIC 10/75-95-155 VEX+SEISMIC 10/100-120-180 VEX+SEISMIC 12/10-30-105 VEX+SEISMIC 12/15-35-110 VEX+SEISMIC 12/20-40-115 VEX+SEISMIC 12/30-50-125 VEX+SEISMIC 12/50-70-145 VEX+SEISMIC 12/65-85-160 VEX+SEISMIC 12/85-105-180 VEX+SEISMIC 12/105-125-200 VEX+SEISMIC 16/15-35-135 VEX+SEISMIC 16/25-45-145 VEX+SEISMIC 16/50-70-170 VEX+SEISMIC 16/80-100-200 VEX+SEISMIC 20/30-165 VEX+SEISMIC 20/60-195
60 80 95 115 90 95 100 110 130 155 180 105 110 115 125 145 160 180 200 135 145 170 200 165 195
-/35 46/35 46/35 46/35 60/40 60/40 60/40 60/40 60/40 60/40 60/40 70/50 70/50 70/50 70/50 70/50 70/50 70/50 70/50 85/65 85/65 85/65 85/65 100/100/-
d0xh1/ d0xh1rid Tfix1/ Tfix2 mm mm
Tinst Nm
Ch
8x60/8x49 8x60/8x49 8x60/8x49 8x60/8x49 10x75/10x55 10x75/10x55 10x75/10x55 10x75/10x55 10x75/10x55 10x75/10x55 10x75/10x55 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 16x110/16x90 16x110/16x90 16x110/16x90 16x110/16x90 20x125/20x125/-
20 20 20 20 25 25 25 25 25 25 25 45 45 45 45 45 45 45 45 90 90 90 90 160 160
13 13 13 13 17 17 17 17 17 17 17 19 19 19 19 19 19 19 19 24 24 24 24 30 30
** Not suitable for fixing Cat. C1 - C2
6/15/26 30/41 50/61 10/30 15/35 20/40 30/50 50/70 75/95 100/120 10/30 15/35 20/40 30/50 50/70 65/85 85/105 105/125 15/35 25/45 50/70 80/100 30/60/-
h1 = Min. hole depth Lt = Anchor length d0 = Hole diameter d = Screw diameter Tfix = Fixture thickness Tinst = Torque Ch = Spanner Lb = Stud length hef = Effective anchorage depth
* Annex E -
C1-C2
* R30-R120
* Only standard anchorage depth
91
through-setting heawy duty anchors
Vorpa VEX+SEISMIC Heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete
Cracked and non-cracked concrete
Technical data VEX+SEISMIC A4 Stainless Steel
Code
4662 4675 4676 4677 4678 4679 4680 4681 4682 4683 4684 4685 4686 4687 4688 4689 4690 4691 4692 4693 4694 4695
Description
Lt mm
hef/ hefrid mm
VEX+SEISMIC A4 10/10-30-90 VEX+SEISMIC A4 10/15-35-95 VEX+SEISMIC A4 10/20-40-100 VEX+SEISMIC A4 10/30-50-110 VEX+SEISMIC A4 10/50-70-130 VEX+SEISMIC A4 10/75-95-155 VEX+SEISMIC A4 10/100-120-180 VEX+SEISMIC A4 12/10-30-105 VEX+SEISMIC A4 12/15-35-110 VEX+SEISMIC A4 12/20-40-115 VEX+SEISMIC A4 12/30-50-125 VEX+SEISMIC A4 12/50-70-145 VEX+SEISMIC A4 12/65-85-160 VEX+SEISMIC A4 12/85-105-180 VEX+SEISMIC A4 12/105-125-200 VEX+SEISMIC A4 16/5-25-125 VEX+SEISMIC A4 16/15-35-135 VEX+SEISMIC A4 16/25-45-145 VEX+SEISMIC A4 16/50-70-170 VEX+SEISMIC A4 16/80-100-200 VEX+SEISMIC A4 20/30-165 VEX+SEISMIC A4 20/60-195
90 95 100 110 130 155 180 105 110 115 125 145 160 180 200 125 135 145 170 200 165 195
60/40 60/40 60/40 60/40 60/40 60/40 60/40 80/50 80/50 80/50 80/50 80/50 80/50 80/50 80/50 97/65 97/65 97/65 97/65 97/65 100/100/-
d0xh1/ d0xh1rid Tfix1/ Tfix2 mm mm
Tinst Nm
Ch
10x75/10x55 10x75/10x55 10x75/10x55 10x75/10x55 10x75/10x55 10x75/10x55 10x75/10x55 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 16x110/16x90 16x110/16x90 16x110/16x90 16x110/16x90 16x110/16x90 20x125/20x125/-
35 35 35 35 35 35 35 50 50 50 50 50 50 50 50 110 110 110 110 110 200 200
17 17 17 17 17 17 17 19 19 19 19 19 19 19 19 24 24 24 24 24 30 30
10/30 15/35 20/40 30/50 50/70 75/95 100/120 10/30 15/35 20/40 30/50 50/70 65/85 85/105 105/125 5/25 15/35 25/45 50/70 80/100 30/60/-
h1 = Min. hole depth Lt = Anchor length d0 = Hole diameter d = Screw diameter Tfix = Fixture thickness Tinst = Torque Ch = Spanner Lb = Stud length hef = Effective anchorage depth
* Annex E -
C1-C2
* R30-R120
* Only standard anchorage depth Examples of applications
92
through-setting heawy duty anchors
Vorpa VEX+SEISMIC Heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete
Cracked and non-cracked concrete
Installation data VEX+SEISMIC zincplated Anchor size Nominal drill hole diameter Torque moment Spanner Setting depth Minimum thickness of concrete member Drill hole depth Hole in the fixture
d0 Tinst SW hnom hmin h1 df
[mm] [Nm] [mm] [mm] [mm] [mm] [mm]
M8
M10
M12
M16
M20
M24
M27
8 20 13 46 100 60 9
10 25 17 60 120 75 12
12 45 19 70 140 90 14
16 90 24 85 170 110 18
20 160 30 100 200 125 22
24 200 36 115 230 145 26
28 300 41 125 250 160 30
M8
M10
M12
M16
M20
M24
M27
16 1,53 12,2 1,25 23 1,25 -
27 1,53 20,1 1,25 47 1,25 27 27 1,53 20 14 1,25
40 1,5 30 1,25 82 1,25 40 40 1,5 27 16,2 1,25
60 1,5 55 1,25 216 1,25 60 60 1,5 44 35,7 1,25
86 1,6 69 1,33 363 1,33 86 86 1,6 69 55,2 1,33
126 1,5 114 1,25 898 1,25 -
196 1,5 169,4 1,25 1331,5 1,25 -
12 5 -
16 9 9 3,6
25 16 16 10,2
35 25 25 13,8 1,22 1,41 1,55
1) 1) 36 22,4
1) 1) -
1) 1) -
46 138 69
60 180 90
70 210 105
85 255 127,5 7,2 10,1
100 300 150
115 345 172,5
125 375 187,5
Design method according to ETAG 001 part 1-2 Annex E Anchor size Steel failure Characteristic resistance Tension Partial safety factor Shear Partial safety factor Bending moment Partial safety factor Tension loads C1 Tension loads C2 Partial safety factor Shear loads C1 Shear loads C1 Partial safety factor Pull-out failure Characteristics resistance non cracked concrete C20/25 Characteristics resistance cracked concrete C20/25 Characteristics resistance seismic performance C1 Characteristics resistance seismic performance C2 C30/37 Increasing factor C40/50 C50/60 Concrete cone failure and Anchorage depth
K factor cracked concrete K factor non-cracked concrete
NRk,s YMs VRk,s YMs M0Rk,s YMs NRk,s, C1 NRk,s, C2 YMs, seis VRk, seis, C1 VRk, seis, C2 YMs, seis
[kN] [kN] [Nm] [kN] [kN] [kN] [kN]
NRk,p,ucr NRk,p,cr NRk,seis,C1 NRk,seis,C2
[kN] [kN] [kN] [kN]
Ď&#x2C6;c
[-]
hef scr,sp ccr,sp k k
[mm] [mm] [mm]
1) Pull out it not decisive
93
through-setting heawy duty anchors
Vorpa VEX+SEISMIC Heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete
Cracked and non-cracked concrete
Installation data VEX+SEISMIC A4 stainless steel Anchor size Nominal drill hole diameter Torque moment Spanner Standard sett. depth Minimum thickness of concrete member Drill hole depth Hole in the fixture
d0 Tinst SW hnom hmin h1 df
[mm] [Nm] [mm] [mm] [mm] [mm] [mm]
M8
M10
M12
M16
M20
M24
M27
8 20 13 46 100 60 9
10 35 17 60 120 75 12
12 50 19 70 140 90 14
16 110 24 85 160 110 18
20 200 30 100 200 125 22
24 290 36 125 250 155 26
-
M8
M10
M12
M16
M20
M24
M27
16 1,5 13 1,0 26 1,25 -
27 1,5 20 1,0 52 1,25 27 27 1,5 20 14 1,25
40 1,5 30 1,0 92 1,25 40 40 1,5 27 16,2 1,25
64 1,5 55 1,0 200 1,25 64 64 1,5 44 35,7 1,25
108 1,68 86 1,0 454 1,4 108 108 1,68 69 55,2 1,4
110 1,5 123,6 1,0 785,4 1,25 -
-
12 5 -
16 9 -
25 16 -
35 25 1,22 1,41 1,55
1) 1) -
1) 40 -
-
46 138 69
60 180 90
70 210 105
85 255 127,5 7,2 10,1
100 300 150
125 375 187,5
-
Design method according to ETAG 001 part 1-2 Annex E Anchor size Steel failure Characteristic resistance Tension Partial safety factor Shear Partial safety factor Bending moment Partial safety factor Tension loads C1 Tension loads C2 Partial safety factor Shear loads C1 Shear loads C1 Partial safety factor Pull-out failure Characteristics resistance non cracked concrete C20/25 Characteristics resistance cracked concrete C20/25 Characteristics resistance seismic performance C1 Characteristics resistance seismic performance C2 C30/37 Increasing factor C40/50 C50/60 Concrete cone failure and Anchorage depth
K factor cracked concrete K factor non-cracked concrete
NRk,s YMs VRk,s YMs M0Rk,s YMs NRk,s, C1 NRk,s, C2 YMs, seis VRk, seis, C1 VRk, seis, C2 YMs, seis
[kN] [kN] [Nm] [kN] [kN] [kN] [kN]
NRk,p,ucr NRk,p,cr NRk,seis,C1 NRk,seis,C2
[kN] [kN] [kN] [kN]
Ď&#x2C6;c
[-]
hef scr,sp ccr,sp k k
[mm] [mm] [mm]
1) Pull out it not decisive
94
through-setting heawy duty anchors
Vorpa VEX+SEISMIC Heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete
Cracked and non-cracked concrete
Installation data VEX+SEISMIC reduced anchorage depth fixings M8
M10
M12
M16
8 20 13 35 80 49 9
10 35 17 40 80 55 12
12 50 19 50 100 70 14
16 110 24 65 140 90 18
M8
M10
M12
M16
50 60 40 185
50 100 65 180
50 160 100 185
65 170 170 65
Smin per C≥ Cmin per S≥
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
50 60 40 85
50 100 65 180
50 160 65 250
65 170 100 250
NRk,p,rid
[kN]
5
7,5
1)
1)
50
65
1)
1)
50
65
Anchor size Nominal drill hole diameter Torque moment Spanner Standard sett. depth Minimum thickness of concrete member Drill hole depth Hole in the fixture
d0 Tinst SW hnom,rid hmin h1rid df
[mm] [Nm] [mm] [mm] [mm] [mm] [mm]
M20
M24
M27
M20
M24
M27
Minimum spacing and edge distance reduced anchorage depth Anchor size Non cracked concrete Minimum spacing Minimum edge distance Cracked concrete Minimum spacing Minimum edge distance
Cracked concrete Pull-out failure Characteristic resistance C30/37 Increasing factor C40/50 C50/60 Concrete cone failure Anchorage depth K factor Non-cracked concrete Pull-out failure Characteristic resistance C30/37 Increasing factor C40/50 C50/60 Concrete cone failure Anchorage depth K factor
Smin per C≥ Cmin per S≥
1,22 1,41 1,55
ψc hef, rid
35
40
k
7,2
NRk,p,rid
7,5
9 1,22 1,41 1,55
ψc hef, rid
35
k
40 10,1
1) Pull out is not decisive ATTENTION: Partial technical data. Please consult ETA annexes to verify complete values.
95
through-setting heawy duty anchors
Vorpa VEX+SEISMIC Heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete
Cracked and non-cracked concrete
Installation data VEX+SEISMIC Characteristic values for tension and shear load under fire exposure standard anchorage depth, cracked and non-cracked concrete C20/25 to C50/60, design acc. to TR 020 or CEN/TS 1192-4, Annex D Anchor size Tension load Steel failure Steel zinc plated R30 R60 R90 R120 Stainless steel A4 R30 R60 R90 R120 Shear load Steel failure without lever arm Steel zinc plated R30 R60 R90 R120 Stainless steel A4 R30 R60 R90 R120 Bending moment Steel failure with lever arm Steel zinc plated R30 R60 R90 R120 Stainless steel A4 R30 R60 R90 R120
NRk,s, fi
NRk,s, fi
VRk,s, fi
VRk,s, fi
o
M Rk,s, fi
o
M Rk,s, fi
M8
M10
M12
M16
M20
M24
M27
[kN]
1,4 1,1 0,8 0,7
2,2 1,8 1,4 1,2
3,2 2,8 2,4 2,2
6,0 5,2 4,4 4,0
9,4 8,2 6,9 6,3
13,6 11,8 10,0 9,1
17,6 15,3 13,0 11,8
[kN]
3,8 2,9 2,0 1,6
6,9 5,2 3,5 2,7
11,5 8,6 5,6 4,2
21,5 16 10,5 7,8
33,5 25,0 16,4 12,1
48,2 35,9 23,6 17,4
[kN]
1,6 1,5 1,2 1,0
2,6 2,5 2,1 2,0
3,8 3,6 3,5 3,4
7,0 6,8 6,5 6,4
11 11 10 10
16 15 15 14
[kN]
3,8 2,9 2,0 1,6
6,9 5,2 3,5 2,7
11,5 8,6 5,6 4,2
21,5 16 10,5 7,8
33,5 25,0 16,4 12,1
48,2 35,9 23,6 17,4
[Nm]
1,7 1,6 1,2 1,1
3,3 3,2 2,7 2,5
5,9 5,6 5,4 5,3
15 14 14 13
29 28 27 26
50 48 47 46
[Nm]
3,8 2,9 2,1 1,6
9,0 6,8 4,5 3,4
17,9 13,3 8,8 6,5
45,5 33,9 22,2 16,4
88,8 66,1 43,4 32,1
153,5 114,3 75,1 55,5
96
20,6 19,8 19,0 18,6
75 72 69 68
through-setting heawy duty anchors
Vorpa VE.1CE heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete
Cracked and non cracked concrete
Products group
ETA-19/0885 ETAG 1 Option 1 for cracked concrete
Approved for • Cracked and non-cracked concrete • Static and quasi static loads M8-M20 • Seismic applications C1 - M12 - M16 • Anchorage under fire exposure in standard TR 020 R30-R120
R30-R120
EAD 330232 - 00 - 0601 Option 1 - Cracked and non cracked concrete Seismic fixings - category C1- M12-M16
Suitable to fix • Parapets • Steel beams • Machine tools • Industrial systems • Heavy duty metal constructions • Structural fixings • Seismic application M12-M16
Also suitable for • Natural stone • Concrete C12/C15
FIXING IN SEISMIC Annex E-C1
As it can also be used on concrete with different strength characteristics, as specified in ETA, on compact natural stone and others materials (exception not included in ETA), specific on-site tests by the user are necessary
Product information Installation • Through-setting anchor
Characteristics • Special wedge anchor assembled with hex nut and washer certified ETA-CE option 1 and performance category C1 under seismic action. Benefits • European Technical Approval - Option 1 cat. C1 • High Performance in cracked and non-cracked concrete • Easy installation: just few turns ensures the required installation torque • Fire resistance R30-R120 according to Technical Report TR 020 • Fast and precise installation thanks to be coloured ring (overall anchor embedment depth in the concrete)
Suggestion for use • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
Installation sequence Installation instruction for static and quasi-static loads
Drill a hole into the concrete in rotary plus hammer mode
Remove the dust into the hole using a brush and a blowing pump
1)
Hammer the anchor into the hole
1) Through
fixing is allowed (place the fixture before placing the anchor)
Apply the required torque moment Tinst
97
1)
Place the fixture
through-setting heawy duty anchors
Vorpa VE.1CE heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete
Cracked and non cracked concrete
Technical data
hef
Code
Description
Lt mm
hef mm
d0 x h1 mm
Tfix max mm
Tinst Nm
Ch
92101 92102 92103 92104 92105 92106 92107 92108 92109 92110 92111 92112 92113 92114 92115 92116 92117 92118 92119 92120
VE.1CE 8/5 - 60 VE.1CE 8/20 - 75 VE.1CE 8/40 - 95 VE.1CE 8/60 - 115 VE.1CE 8/75 - 130 VE.1CE 10/10 - 90 VE.1CE 10/20 - 100 VE.1CE 10/30 - 110 VE.1CE 10/40 - 120 VE.1CE 10/80 - 160 VE.1CE 10/100 - 180 VE.1CE SEISMIC 12/5 - 90 VE.1CE SEISMIC 12/20 - 105 VE.1CE SEISMIC 12/35 - 120 VE.1CE SEISMIC 12/50 - 135 VE.1CE SEISMIC 12/80 - 165 VE.1CE SEISMIC 12/100 - 185 VE.1CE SEISMIC 16/15 - 125 VE.1CE SEISMIC 16/40 - 150 VE.1CE SEISMIC 16/100 - 210
60 75 95 115 130 90 100 110 120 160 180 90 105 120 135 165 185 125 150 210
40 40 40 40 40 60 60 60 60 60 60 60 60 60 60 60 60 80 80 80
8x55 8x55 8x55 8x55 8x55 10x75 10x75 10x75 10x75 10x75 10x75 12x75 12x75 12x75 12x75 12x75 12x75 16x100 16x100 16x100
5 20 40 60 75 10 20 30 40 80 100 5 20 35 50 80 100 15 40 100
30 30 30 30 30 50 50 50 50 50 50 70 70 70 70 70 70 130 130 130
13 13 13 13 13 17 17 17 17 17 17 19 19 19 19 19 19 24 24 24
Examples of applications
98
Lt
h1 = Min. hole depth Lt = Anchor length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness Tinst = Torque Ch = Spanner hef = Anchorage depth
through-setting heawy duty anchors
Vorpa VE.1CE heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete
Cracked and non cracked concrete
Installation data Declaration of performance VE.1CE Anchor size Nominal drill hole diameter Maximum cutting diameter of drill bit Installation torque moment Minimum allowable spacing (even in case of fire exposure) Minimum allowable edge distance Wrench size Minimum thickness of concrete member Depth of the drilled hole to deepest point Diameter of clearance hole in the fixture Thickness of fixture
d0 dcut Tinst Smin Cmin SW hmin h1 df tfix
[mm] [mm] [Nm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
M8
M10
M12
M16
8 8,45 30 65 65 13 100 55 9 75
10 10,45 50 150 60 17 120 75 12 100
12 12,5 70 80 80 19 120 75 14 100
16 16,5 130 85 85 24 160 100 18 100
M8
M10
M12
M16
31,6
43,4
75,4
24,7 76,6
45,9 194,8
12 12
35 12
Declared performance according to ETAG001 part 1, part 2 and Annex E Anchor size Steel failure NRk,s ɣms VRk,s M0Rk,s YMs,N
[kN] [-] [kN] [Nm] [-]
22,2
NRk,p,ucr NRk,p,cr
[kN] [kN]
6 3
ψc
[-]
Y2
[-]
1,2
1,2
1,4
1,4
hef Scr,N ccr,N Scr,sp ccr,sp
[mm] [mm] [mm] [mm] [mm]
40 120 60 200 100
60 180 90 300 150
60 180 90 360 180
80 240 120 400 200
Concrete pry-out failure K factor
k
[-]
1,0
2,0
2,0
2,00
Concrete edge failure Effective length of anchor Outside diameter of anchor Installation safety factor
lf = hef dnom ɣ2
[mm] [mm] [-]
40 8
60 10
60 12
80 16
Installation safety factor Characteristic resistance Partial safety factor Pull-out failure Characteristic resistance in uncracked concrete C20/25 Characteristic resistance in cracked concrete C20/25 C30/37 Increasing factor for concrete C40/50 C50/60 Installation safety factor Concrete cone failure and splitting failure Effective anchorage depth Critical spacing for concrete cone failure Critical edge distance for concrete cone failure Critical spacing for splitting failure Critical edge distance for splitting failure
99
1,88 8,1 22,8
17,6 45,5 1,25
12 9 1,22 1,41 1,55
1,0
through-setting heawy duty anchors
Vorpa VE.1CE heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete
Cracked and non cracked concrete
Installation data Declared performance according to EAD 330232-00-0601 part 1, part 2 and Annex E Anchor size
M8
M10
M12
M16
Steel Failure under fire exposure in concrete C20/25 to C50/60 Characteristic resistance to tension and shear loads
Characteristic bending moments
R30 R60 R90 R120 R30 R60 R90 R120
FRk,s,fi,30 FRk,s,fi,60 FRk,s,fi,90 FRk,s,fi,120 M0Rk,s,fi,30 M0Rk,s,fi,60 M0Rk,s,fi,90 M0Rk,s,fi,120
[kN] [kN] [kN] [kN] [Nm] [Nm] [Nm] [Nm]
0,4 0,3 0,3 0,2 0,4 0,3 0,3 0,2
0,9 0,8 0,6 0,5 1,1 1,0 0,7 0,6
1,7 1,3 1,1 0,8 2,6 2,0 1,7 1,3
3,1 2,4 2,0 1,6 6,7 5,0 4,3 3,3
R 30 to R 90 R 120
NRk,p,fi NRk,p,fi 120
[kN] [kN]
0,8 0,6
2,3 1,8
3,0 2,4
4,0 3,2
R 30 to R 90 R 120
NRk,c,fi NRk,c,fi 120
[kN] [kN]
1,8 1,5
5,0 4,0
5,0 4,0
10,3 8,2
Pull-out failure Characteristic resistance Concrete cone failure Characteristic resistance
Characteristic values of resistance under tension loads in case of seismic performance category C1 for design acc. to TR045 Anchor size
M16
M12
Steel failure Characteristic resistance Partial safety factor
NRk,s,seis ɣMs,seis
[kN] [-]
43,4
Pullout failure Characteristic resistance Partial safety factor
NRk,p,seis ɣ2 = ɣinst
[kN] [-]
12
75,4 1,881)
12 1,4
Characteristic values of resistance under shear loads in case of seismic performance category C1 for design acc. to TR045 Anchor size Steel failure without lever arm Characteristic resistance Partial safety factor
M16
M12
VRk,s,seis ɣMs,seis
[kN] [-]
1) In absence of other national regulations
100
24,8
13,6 1,251)
through-setting heawy duty anchors
Vorpa VE.7CE
Steel anchors with ETA option 7 for non-cracked concrete
Non-cracked concrete
Products group Approved for • Non-cracked concrete • Static and quasi static loads M6-M16
VE.7CE
Also suitable for • Natural stone • Concrete C12/C15
European Technical Approval Option 7 for non-cracked concrete
As it can also be used on concrete with different strength characteristics, as specified in ETA, on compact natural stone and others materials (exception not included in ETA), specific on-site tests by the user are necessary
To fix • Plants engineering • Heavy structural works • Metal structures • Profiles • Gates • Stairs • Parapets
Software Vorpa Calcul Anchor
Product information Characteristics • High performances through steel anchor composed of steel pin, nut, washer and expansion clip. • When the hexagonal nut is tightened, the tapered bolt is pulled into the expansion clip and expands it against the drill hole wall. Benefits • Reduced hole diameter • Suitable for through-setting applications in concrete • Thread diameter and hole diameter are the same • Reinforced anchor’s head to avoid damaging the thread during the installation
Benefits • Special designed expansion clip granting a smooth expansion and avoiding the rotation of the anchor during the installation Installation • Through-setting anchor Suggestion for use • Choose the right size of the anchor related to the object to be fixed • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
Installation sequence
Examples of applications
101
through-setting heawy duty anchors
Vorpa VE.7CE
Steel anchors with ETA option 7 for non-cracked concrete
Non-cracked concrete
Technical data
VE.7CE
Code
4637 4638 4639 4640 4641 4642 4643 4644 4645 4646 4696 4647 4648 4649 4650 4651 4652 4653 4654 4655 4656 4657 4658 4659
Description
Lt mm
d0 mm
h1 mm
VE.7CE 6/ 10-55 VE.7CE 6/ 20-65 VE.7CE 8/ 1-55 VE.7CE 8/ 1-65 VE.7CE 8/ 15-80 VE.7CE 8/ 30-95 VE.7CE 8/ 50-115 VE.7CE 8/ 65-130 VE.7CE 10/ 1-75 VE.7CE 10/ 15-105 VE.7CE 10/ 25-105 VE.7CE 10/ 45-120 VE.7CE 10/ 75-150 VE.7CE 12/ 10-90 VE.7CE 12/ 15-110 VE.7CE 12/ 25-120 VE.7CE 12/ 45-140 VE.7CE 12/ 65-160 VE.7CE 12/ 85-180 VE.7CE 16/ 5-125 VE.7CE 16/ 20-140 VE.7CE 16/ 30-150 VE.7CE 16/ 55-175 VE.7CE 16/ 100-220
55 65 55 65 80 95 115 130 75 105 105 120 150 90 110 120 140 160 180 125 140 150 175 220
6 6 8 8 8 8 8 8 10 10 10 10 10 12 12 12 12 12 12 16 16 16 16 16
55 55 65 65 65 65 65 65 70 70 70 70 70 90 90 90 90 90 90 110 110 110 110 110
** **
**
**
tfix max mm
10 20 1 ** 1 ** 15 30 50 65 1 ** 15 25 45 75 10 ** 15 25 45 65 85 5 20 30 55 100
Tinst Nm
Ch
5 5 15 15 15 15 15 15 25 25 25 25 25 45 45 45 45 45 45 100 100 100 100 100
10 10 13 13 13 13 13 13 17 17 17 17 17 19 19 19 19 19 19 24 24 24 24 24
The letter on the top of the head indicated the anchors lenght.
Lettera ≥ < Lettera ≥ <
A 50 N 170 180
B 50 60 O 180 190
C 60 70 P 190 200
D 70 80 Q 200 220
E 80 90 R 220 240
F 90 10 S 240 260
G 100 110 T 260 280
H 110 120 U 280 300
I 120 130 V 300 320
102
J 130 140 W 320 340
K 140 150 X 340 360
L 150 160 Y 360 380
M 160 170 Z 380 400
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
** Reduced anchorage depth - not included in European Technical Approval
through-setting heawy duty anchors
Vorpa VE.7CE
Steel anchors with ETA option 7 for non-cracked concrete
Non-cracked concrete
Installation data Anchor type Installation data VE.7CE Anchor diameter Effective anchorage depth Drill hole diameter Drill hole depth Hole diameter in the fixture Torque moment Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum thickness member Characteristic values Pull out failur non cracked concrete Ψc C30/37 Ψc C40/50 Ψc C50/60
M6
M8
M10
M12
M16
d hef d0 h1 df Tinst Scr,N Ccr,N Smin Cmin hmin
mm mm mm mm mm mm Nm mm mm mm mm
6 40 6 55 7 5 120 60 60 60 100
8 45 8 65 9 15 135 70 67,5 67,5 100
10 51 10 70 12 25 155 80 76,5 76,5 105
12 66 12 90 14 45 200 100 99 99 135
16 80 16 110 18 100 240 120 120 120 160
Nrk,P C20/25
KN
4 1,08 1,15 1,19
9 1,08 1,15 1,19
12 1,08 1,15 1,19
16 1,08 1,15 1,19
30 1,08 1,15 1,19
4 6,1
7,3 15
11,6 29,9
16,9 52,4
31,4 133,2
2,6 3,2 4,8
6 5,8 12
8 9,2 23,9
8,8 13,5 41,9
16,6 25,1 106,5
1,8 2,2 3,4
4,2 4,1 8,5
5,7 6,5 17
6,2 9,6 29,9
11,8 17,9 76
VRk,S C20/25 Shear failure KN MRK,S Bending moment Nm Values where the reduction factor γ is included (Design loads) Nrk,P Pull out failure KN VRk,S Shear failure KN MRK,S Bending moment Nm Recommended loads N Pull out failure KN T Shear failure KN M Bending moment Nm
103
through-setting heawy duty anchors
Vorpa VE.7CE INOX A4
Steel anchors with ETA option 7 for non-cracked concrete
Non-cracked concrete
Products group VE.7CE INOX A4 (A4 stainless steel)
Approved for • Non-cracked concrete • Static and quasi static loads M6-M20 • Anchorage under fire exposure in standard TR 020 R30-R120
European Technical Approval Option 7 for non-cracked concrete
As it can also be used on concrete with different strength characteristics, as specified in ETA, on compact natural stone and others materials (exception not included in ETA), specific on-site tests by the user are necessary
To fix • Plants engineering • Heavy structural works • Metal structures • Profiles • Gates • Stairs • Parapets
Also suitable for • Natural stone • Concrete C12/C15
Software Vorpa Calcul Anchor
Product information Characteristics • High performances through steel anchor composed of steel pin, nut, washer and expansion clip. • When the hexagonal nut is tightened, the tapered bolt is pulled into the expansion clip and expands it against the drill hole wall. Benefits • Reduced hole diameter • Suitable for through-setting applications in concrete • Thread diameter and hole diameter are the same • Reinforced anchor’s head to avoid damaging the thread during the installation
Benefits • Special designed expansion clip granting a smooth expansion and avoiding the rotation of the anchor during the installation Installation • Through-setting anchor Suggestion for use • Choose the right size of the anchor related to the object to be fixed • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
Installation sequence
Examples of applications
104
through-setting heawy duty anchors
Vorpa VE.7CE INOX A4
Steel anchors with ETA option 7 for non-cracked concrete
Non-cracked concrete
Technical data
VE.CE 7 INOX A4 (A4 Stainless Steel) Code
4620 4621 4622 4623 4624 4625 4626 4627 4628 4629 4630 4631 4632 4633 4634 4635 4636
Description
Lt mm
VE.7CE A4 8/50-5 VE.7CE A4 8/75-10-19 VE.7CE A4 8/95 -30-39 VE.7CE A4 8/120-55-64 VE.7CE A4 10/60-10 VE.7CE A4 10/90-15-21 VE.7CE A4 10/120-45-51 VE.7CE A4 10/145-70-76 VE.7CE A4 12/75-5 VE.7CE A4 12/110-15-30 VE.7CE A4 12/125-30-45 VE.7CE A4 12/145-50-65 VE.7CE A4 16/115-14 VE.7CE A4 16/150-30-46 VE.7CE A4 16/180-60-76 VE.7CE A4 20/150-5-27 VE.7CE A4 20/180-35-57
50 75 95 120 60 90 120 145 75 110 125 145 115 150 180 150 180
d0 mm
8 8 8 8 10 10 10 10 12 12 12 12 16 16 16 20 20
h1 /h1rid mm
-/45 65/55 65/55 65/55 -/50 70/65 70/65 70/65 -/65 90/75 90/75 90/75 -/95 110/95 110/95 130/110 130/110
tfix / tfix2 mm
-/5 10/19 30/39 55/64 -/10 15/21 45/51 70/76 -/5 15/30 30/45 50/65 -/14 30/46 60/76 5/27 35/57
Attention: The use of the Tfix2 causes reduced effective anchorage depth and reduced loads
Examples of applications
105
Tinst Nm
Ch
15 15 15 15 25 25 25 25 50 50 50 50 100 100 100 160 160
13 13 13 13 17 17 17 17 19 19 19 19 24 24 24 30 30
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
through-setting heawy duty anchors
Vorpa VE.7CE INOX A4
Steel anchors with ETA option 7 for non-cracked concrete
Non-cracked concrete
Installation data Anchor type Installation data Performance data Effective anchorage depth Reduced anchorage depth Drill hole diameter Drill hole diameter in the fixture Drill hole depth Torque moment Width across nut
hef hef,red d0 d0 h1 Tinst SW
Spacing and edge distance Effective anchorage depth Characteristic spacing Characteristic edge distance Minimum spacing Minimum edge distance Minimum thickness of concrete slab
hef Scr,N Ccr,N Smin Cmin hmin
Characteristic values - Effective anchorage depth (hef) Pull out failure C25/30 Ψc C30/37 Ψc C40/50 Ψc C20/60 V Shear failure M Bending moment Design loads - Effective anchorage depth (hef) N Pull out failure V Shear failure M Bending moment Recommended loads N Pull out failure V Shear failure M Bending moment 1) Application
M8
M10
M12
M16
M20
mm mm mm mm mm Nm mm
44 - - 351) 8 8 9 9 65 55 15 15 13 13
48 - - 42 10 10 12 12 70 65 25 25 17 17
65 - - 50 12 12 14 14 90 75 50 50 19 19
80 - - 64 16 16 18 18 110 95 100 100 24 24
100 - - 78 20 20 22 22 130 110 160 160 30 30
mm mm mm mm mm mm
44 351) 132 105 66 52,5 35 60 45 60 100 80
48 42 144 126 72 63 45 55 55 65 100 100
65 50 195 150 97,5 75 60 100 70 100 130 100
82 64 246 192 123 96 80 110 80 110 160 130
100 78 300 234 150 117 100 140 100 140 200 160
kN Nm
kN kN Nm kN kN Nm
M8 9 1,22 1,41 1,55 12 24
M10 12 1,22 1,41 1,55 19 49
M12 20 1,22 1,41 1,55 27 85
M16 30 1,22 1,41 1,55 50 199
M20 40 1,22 1,41 1,55 86 454
M8 6 9,6 19,2 M8 4,2 6,8 13,7
M10 8 15,2 39,2 M10 5,7 10,8 28
M12 13,3 21,6 68 M12 9,5 15,4 48
M16 20 40 159,2 M16 14,2 28,5 113,5
M20 26,6 61,4 324,2 M20 19 43,8 231
limited to statically indeterminated systems.
106
through-setting heawy duty anchors
Vorpa VE.A Steel anchors
Non-cracked concrete
Products group VE.A
Suitable for • Non-cracked concrete
VE.A ZF / VE.A ZG hot dip galvanized Geomet galvanized
VE.A INOX A2 (A2 stainless steel)
To fix • Steel beams • Sections • Plates • Heavy structural works • Plants engineering • Railings and balustrades • Gates
Test reports available
VE.A INOX A4 (A4 stainless steel)
Software Vorpa Calcul Anchor
VE.A M internal thread VE.A M INOX A2 internal thread (A2 stainless steel)
[*] Option 7 for non-cracked concrete
[*] VE.CE 7 Ø16 extralong fixings
Examples of applications
Installation sequence
107
through-setting heawy duty anchors
Vorpa VE.A Steel anchors
Non-cracked concrete
Product information Characteristics • Through steel anchor composed of steel pin, nut, washer and expansion clip. The version with internal thread VE.A M to be used with bolts of any metrical length. • When the hexagonal nut is tightened, the tapered bolt is pulled into the expansion clip and expands it against the drill hole wall. Benefits • Thread diameter and hole diameter are the same • Reinforced anchor’s head to avoid damaging the thread during the installation • Anti-rotation during the installation procedure and smooth expansion thanks to the particular shape of the clip
Benefits • High load values and fast setting • Hot dip galvanized version VE.A ZF and Geomet galvanized VE.A ZG for outdoor use and damp conditions Installation • Through-setting anchor Suggestion for use • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
Technical data
VE.A
Code
1601 1646TW 1602 1625 1603 1639 1604 51604 1605 1618 1606 51605 51606 51607 51609 1607 51608 1608 5626 1609 1614 1641 1643 1610 1626 5611 1611 1640 1612 1627 1613 1637 5621 5622 5623
Description
Lt mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Ch
VE.A 6/5-45 VE.A 6/7-55 VE.A 6/10-65 VE.A 6/25-80 VE.A 6/40-100 VE.A 6/70-130 VE.A 8/5-55 VE.A 8/10-60 VE.A 8/15-75 VE.A 8/25-90 VE.A 8/50-115 VE.A 8/70-130 VE.A 8/100-160 VE.A 8/120-180 VE.A 8/140-200 VE.A 10/5-65 VE.A 10/10-80 VE.A 10/20-90 VE.A 10/30-100 VE.A 10/50-120 VE.A 10/70-140 VE.A 10/100-170 VE.A 10/140-210 VE.A 12/10-75 VE.A 12/15-90 VE.A 12/20-100 VE.A 12/20-110 VE.A 12/30-120 VE.A 12/50-145 VE.A 12/65-160 VE.A 12/85-180 VE.A 12/100-200 VE.A 14/15-110 VE.A 14/30-145 VE.A 14/60-175
45 55 65 80 100 130 55 60 75 90 115 130 160 180 200 65 80 90 100 120 140 170 210 75 90 100 110 120 145 160 180 200 110 145 175
6 6 6 6 6 6 8 8 8 8 8 8 8 8 8 10 10 10 10 10 10 10 10 12 12 12 12 12 12 12 12 12 14 14 14
35 40 50 50 55 55 40 40 55 55 55 55 55 55 55 50 60 60 60 60 60 60 60 55 65 80 80 80 85 85 85 85 85 110 105
5 7 10 25 40 70 5 10 15 25 50 70 100 120 140 5 10 20 30 50 70 100 140 10 15 20 20 30 50 65 85 100 15 30 60
10 10 10 10 10 10 20 20 20 20 20 20 20 20 20 45 45 45 45 45 45 45 45 65 65 65 65 65 65 65 65 65 85 85 85
10 10 10 10 10 10 13 13 13 13 13 13 13 13 13 17 17 17 17 17 17 17 17 19 19 19 19 19 19 19 19 19 22 22 22
108
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
Follows on the next page
through-setting heawy duty anchors
Vorpa VE.A Steel anchors
Non-cracked concrete
Technical data
VE.A
Code
1629 1615 1636 1616 1620 1638 1617 1624 618 1644 619 1628 1619 1642
Description
Lt mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Ch
VE.A 16/5-90 VE.A 16/10-110 VE.A 16/20-125 VE.A 16/30-145 VE.A 16/60-175 VE.A 16/90-200 VE.A 16/105-220 VE.A 20/15-145 VE.A 20/30-170 VE.A 20/60-200 VE.A 20/80-220 VE.A 20/130-270 VE.A 24/25-180 VE.A 24/100-260
90 110 125 145 175 200 220 145 170 200 220 270 180 260
16 16 16 16 16 16 16 20 20 20 20 20 24 24
70 85 90 100 100 100 100 110 120 120 120 120 135 135
5 10 20 30 60 90 105 15 30 60 80 130 25 100
115 115 115 115 115 115 115 200 200 200 200 200 320 320
24 24 24 24 24 24 24 30 30 30 30 30 36 36
Tinst Nm
Ch
20 20 20 40 40 40 50 50 50 125 125 250 320
13 13 13 17 17 17 19 19 19 24 24 30 36
20 20 20 20 40 40 40 50 50 50 125 125 250 320
13 13 13 13 17 17 17 19 19 19 24 24 30 36
VE.A ZF hot dip galvanized
Code
4604 4605 4606 4607 4608 4609 4611 4612 4613 4615 4616 4618 4619
Description
VE.A ZF VE.A ZF VE.A ZF VE.A ZF VE.A ZF VE.A ZF VE.A ZF VE.A ZF VE.A ZF VE.A ZF VE.A ZF VE.A ZF VE.A ZF
8/3-65 8/10-80 8/30-100 10/5-80 10/15-90 10/45-120 12/20-110 12/50-145 12/90-180 16/10-125 16/35-150 20/30-160 24/20-180
Lt mm
d0 mm
h1 mm
65 80 100 80 90 120 110 145 180 125 150 160 180
8 8 8 10 10 10 12 12 12 16 16 20 24
40 55 55 50 60 60 80 80 80 85 100 120 135
tfix max mm
3 10 30 5 15 45 20 50 90 10 35 30 20
VE.A ZG Geomet galvanized
54604 54605 54606 54620 54607 54617 54621 54611 54612 54622 54615 54616 54618 54619
VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG
8/3-65 8/10-80 8/30-100 8/15-115 10/5-80 10/15-90 10/45-120 12/20-110 12/50-145 12/90-180 16/10-125 16/35-150 20/30-160 24/20-180
65 80 100 115 80 90 120 110 145 180 125 150 160 180
8 8 8 8 10 10 10 12 12 12 16 16 20 24
40 55 55 55 50 60 60 80 80 80 85 100 120 135
3 10 30 15 5 15 45 20 50 90 10 35 30 20
109
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
through-setting heawy duty anchors
Vorpa VE.A Steel anchors
Non-cracked concrete
Technical data
VE.A INOX A2 (A2 Stainless Steel)
Code
Description
Lt mm
d0 mm
h1 mm
2601 2600 2602 2603 2604 2605 2618 2627 2606 2607 2617 2608 2609 2610 2613 5607 5608 2611 2630 2611S 2612 2629 2615 2619 2616 2620 2621 2622
VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2
45 55 65 85 55 75 90 95 115 65 75 90 120 75 80 90 100 110 120 130 145 90 110 125 145 175 160 180
6 6 6 6 8 8 8 8 8 10 10 10 10 12 12 12 12 12 12 12 12 16 16 16 16 16 20 20
30 45 50 60 40 55 55 55 55 50 60 60 60 55 50 80 80 80 80 85 85 70 75 75 100 100 120 120
6/10-45 6/5-55 6/10-65 6/20-85 8/5-55 8/15-75 8/25-90 8/30-95 8/50-115 10/5-65 10/10-75 10/20-90 10/50-120 12/10-75 12/20-80 12/15-90 12/20-100 12/20-110 12/30-120 12/35-130 12/50-145 16/5-90 16/20-110 16/35-125 16/30-145 16/65-175 20/20-160 20/40-180
tfix max mm
10 5 10 20 5 15 25 30 50 5 10 20 50 10 20 15 20 20 30 35 50 5 20 35 30 65 20 40
Tinst Nm
Ch
10 10 10 10 20 20 20 20 20 45 45 45 45 65 65 65 65 65 65 65 65 115 115 115 115 115 200 200
10 10 10 10 13 13 13 13 13 17 17 17 17 19 19 19 19 19 19 19 19 24 24 24 24 24 28 28
Tinst Nm
Ch
10 10 20 20 20 20 20 20 45 45 45 45 45 45 45
10 10 13 13 13 13 13 13 17 17 17 17 17 17 17
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
VE.A INOX A4 (A4 Stainless Steel)
Code
Description
Lt mm
d0 mm
13750 13751 13752 13753 13774 13765 13780 13754 13755 13776 13756 13781 13757 13766 13775
VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4
55 85 65 80 105 115 120 130 65 80 90 100 120 130 140
6 6 8 8 8 8 8 8 10 10 10 10 10 10 10
6/10-55 6/25-85 8/10-65 8/20-80 8/45-105 8/50-115 8/55-120 8/80-130 10/10-65 10/15-80 10/20-90 10/30-100 10/50-120 10/60-130 10/70-140
h1 mm
40 55 45 55 55 55 55 45 45 60 60 60 60 60 60
tfix max mm
10 25 10 20 45 50 55 80 10 15 20 30 50 60 70
110
Follows on the next page
through-setting heawy duty anchors
Vorpa VE.A Steel anchors
Non-cracked concrete
Technical data
VE.A INOX A4 (A4 Stainless Steel)
Code
Description
Lt mm
d0 mm
h1 mm
13777 13758 52611 13767 13759 13760 13763 13768 13778 13761 13762 13769
VE.A A4 12/20-80 VE.A A4 12/10-100 VE.A A4 12/20-110 VE.A A4 12/20-120 VE.A A4 12/50-140 VE.A A4 12/80-180 VE.A A4 16/5-100 VE.A A4 16/10-110 VE.A A4 16/35-125 VE.A A4 16/50-150 VE.A A4 16/60-175 VE.A A4 20/30-175
80 100 110 120 140 180 100 110 125 150 175 175
12 12 12 12 12 12 16 16 16 16 16 20
50 80 80 90 80 90 80 85 80 100 100 125
mm mm mm mm mm mm
M6 180 70 90 35 100 7
VE.A Anchor Scr Critical axial spacing Ccr Critical edge distance Smin Minimum axial spacing Cmin Minimum edge distance Minimum structural thickness hmin Through hole in the object to be fixed
M8 190 80 95 40 100 9
tfix max mm
20 10 20 20 50 80 5 10 35 50 60 30
M10 220 100 110 50 100 12
M12 300 120 150 60 150 14
M14 340 150 170 75 180 16
Tinst Nm
Ch
65 65 65 65 65 65 115 115 115 115 115 200
19 19 19 19 19 19 24 24 24 24 24 28
M16 380 170 190 85 180 18
Permissible loads - applications in concrete C20/25 VE.A
daN
M20 440 240 220 105 210 22
Description
13770 13771 13772 13773
VE.A M VE.A M VE.A M VE.A M
6/50 8/50 10/60 12/75
1 daN ≃1 kg 245
420
520
770
850
950
1390
1850 h1
Lt mm
M mm
d0 mm
h1 mm
Tinst Nm
50 50 60 75
M6 M8 M10 M12
8 10 12 16
55 55 65 80
10 20 45 65
VE.A M INOX A2 internal thread (A2 Stainless Steel)
13770 A2 13771 A2 13772 A2 13773 A2
VE.A A2 M VE.A A2 M VE.A A2 M VE.A A2 M
6/50 8/50 10/60 12/75
VE.A M Anchor Scr Critical axial spacing Ccr Critical edge distance Smin Minimum axial spacing Cmin Minimum edge distance Minimum structural thickness hmin Through hole in the object to be fixed
50 50 60 75
M6 M8 M10 M12
mm mm mm mm mm mm
M6/Ø8 180 70 90 35 100 7
8 10 12 16 M8/Ø10 190 80 95 40 100 9
55 55 65 80
M10/Ø12 220 100 110 50 100 12
daN
M
Screw length calculation: Lv = Lt + tfix
10 20 45 65
h1 = Min. hole depth Lt = Anchor length d0 = Hole diameter tinst = Torque M = Internal thread
M12/Ø16 300 120 150 60 150 14
Permissible loads - applications in concrete C20/25 VE.A M
h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
M24 520 240 290 115 240 26
VE.A M internal thread Code
Screw length calculation: Lv = Lt + tfix
1 daN ≃1 kg 220
340
480
620
- Always respect the installation parameters - In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) - The table shows the permissible loads for tension, shear and combined tension and shear loads.
111
through-setting heawy duty anchors
Vorpa VE.A Steel anchors
Non-cracked concrete
Technical data VE.CE7 diameter 16 extra long steel anchor fixing system for wooden beams on non-cracked concrete Option 7 with A2 stainless steel clip Code
2227 2228 2229 2230 2235 2236 2237
Description
Lt mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Ch
VE.CE 7 16/125-240 VE.CE 7 16/145-260 VE.CE 7 16/165-280 VE.CE 7 16/185-300 VE.CE 7 16/215-330 VE.CE 7 16/245-360 VE.CE 7 16/280-400
240 260 280 300 330 360 400
16 16 16 16 16 16 16
120 120 120 120 120 120 120
125 145 165 185 215 245 280
100 100 100 100 100 100 100
24 24 24 24 24 24 24
h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
Attention: Steel anchor diameter 16 length over 220mm assembled with washer DIN 9021. Thickness of wooden beams up to 280mm
Installation data Anchor type Installation data VE.CE7 Anchor diameter Anchor length
M16
M16 Lungo
d L
mm mm
16 120-220
16 221-400
hef Tfix d0 h1 df Tinst Scr,N Ccr,N Smin Cmin hmin
mm mm mm mm mm Nm mm mm mm mm mm
75,8 1-245 16 120 18 100 270 135 96 128 200
75,8 280 16 120 18 100 270 135 96 128 200
Nrk,P C20/25
KN
25 1,22 1,41 1,55
25 1,22 1,41 1,55
VRk,S C20/25 MRK,S
KN Nm
39,3 166
13,5 166
Values where the reduction factor γ is included (Design loads) Nrk,P Pull out failure KN VRk,S Shear failure KN MRK,S Bending moment Nm
13,9 31,4 132,8
13,9 10,8 132,8
Recommended loads Pull out failure Shear failure Bending moment
9,9 22,4 75
9,9 7,7 75
Effective anchorage depth Fixture thickness Drill hole diameter Drill hole depth Hole diameter in the fixture Torque moment Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum thickness member Characteristic values Pull out failure non cracked concrete Ψc C30/37 Ψc C40/50 Ψc C50/60 Shear failure Bending moment
N T M
KN KN Nm
112
Screw length calculation: Lv = Lt + tfix
through-setting heawy duty anchors
Vorpa VE Steel anchors
Non-cracked concrete
Products group Suitable for • Non-cracked concrete
Test reports available
To fix • Plants engineering • Heavy structural works • Metal structures • Profiles • Gates • Stairs • Parapets • Machineries • Balustrades
Software Vorpa Calcul Anchor
Examples of applications
Product information Characteristics • High performances through steel anchor composed of steel pin, nut, washer and two stainless steel expansion clips. • When the hexagonal nut is tightened, the tapered bolt is pulled into the expansion clip and expands it against the drill hole wall Benefits • Reduced hole diameter • Suitable for through-setting applications in concrete • Thread diameter and hole diameter are the same • Reinforced anchor’s head to avoid damaging the thread during the installation • Minimum slippage due to powerfull expansion when tightening • Fast setting also thanks to pre-mounted nut and washer
Installation • Through-setting anchor Suggestion for use • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
113
through-setting heawy duty anchors
Vorpa VE Steel anchors
Non-cracked concrete
Installation sequence
Technical data
Code
601 602 603 604 605 599 606 607 608 609 610 611 612 613 614 615 600 616 589 617
Description
Lt mm
L. thread mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Ch
VE 6/5-45 VE 6/15-65 VE 6/40-100 VE 8/5-55 VE 8/10-75 VE 8/25-90 VE 8/50-115 VE 10/10-65 VE 10/20-90 VE 10/40-120 VE 12/5-75 VE 12/15-110 VE 12/25-145 VE 12/80-180 VE 14/15-110 VE 14/25-145 VE 16/10-110 VE 16/25-145 VE 16/55-175 VE 16/100-220
45 65 100 55 75 90 115 65 90 120 75 110 145 180 110 145 110 145 175 220
19 39 74 20 40 55 75 26 42 71 27 45 90 90 45 75 46 78 81 96
6 6 6 8 8 8 8 10 10 10 12 12 12 12 14 14 16 16 16 16
35 45 55 40 60 55 55 45 60 70 60 85 110 90 85 110 85 105 105 105
5 15 40 5 10 25 50 10 20 40 5 15 25 80 15 25 10 25 55 100
10 10 10 20 20 20 20 45 45 45 65 65 65 65 85 85 115 115 115 115
10 10 10 13 13 13 13 17 17 17 19 19 19 19 22 22 24 24 24 24
Installation data
VE Anchor Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness
Scr Ccr Smin Cmin hmin
mm mm mm mm mm
M6 180 70 90 35 100
M8 190 80 95 40 100
M10 220 100 110 50 100
M12 300 120 150 60 150
M14 340 150 170 75 180
Permissible loads - applications in concrete C20/25 VE - - -
daN
M16 380 170 190 85 180
M20 440 240 220 105 210
1 daN â&#x2030;&#x192;1 kg 250
380
520
800
850
1400
1750
Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.
114
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
heavy duty anchors
Vorpa VE.A L
Safe fastening of reinforcing mats for sprayed concrete
Concrete
Naturale stone
Products group To fix • reinforcing
Suitable for • concrete • natural stone Examples of applications
Product information Installation • Hammer-in anchor
Characteristics • Self expanding hammer-in anchor designed to attach steel reinforcing mats to existing concrete Benefits • Safe and fastening • Thread diameter and hole diameter are the same • The non threaded end is bent to hold the reinforcement mat in place
Suggestion for use • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
Technical data h1
Description
Lt mm
d0 mm
h1 mm
tfix max mm
lb mm
hef mm
91629 VE.A L 8/20-80 91630 VE.A L 8/50-110 91631 VE.A L 8/80-140
80 110 140
8 8 8
65 65 65
20 50 80
32 35 35
55 55 55
Code
Installation sequence h1 Lt d0 tfix
Installation data Permissible loads - applications in concrete C20/25 VE.A L 8
1 daN ≃1 kg Tension 570
Shear 630
115
= Min. hole depth = Anchor length = Hole diameter = Fixture thickness
through-setting heawy duty anchors
Vorpa VSA heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete
Cracked and non-cracked concrete
Products group VSA V with 8.8 hexagonal head
VSA B with stud and nut
VSA S with 10.9 flat countersunk head
Approved for • Cracked concrete C20/25 to C50/60 • Non cracked concrete C20/25 to C50/60 Also suitable for • Concrete C12/15 • Natural stone
Suitable • parapets • steel beams • machine tools • industrial systems • heavy duty metal constructions • structural fixings
FIXING IN SEISMIC Annex E-C1 IN PROGRESS
ETA-19/0885 ETAG 1 Option 1 for cracked concrete
R30-R120 European technical assesment EAD 330232 - 00 - 0601 Cracked and non-cracked concrete seismic fixing - Cat. C1, M8-M12 (in progress)
Software Vorpa Calcul Anchor As it can also be used on concrete with different strength characteristics, as specified in ETA, on compact natural stone and others materials (exception not included in ETA), specific on-site tests by the user are necessary
Examples of applications
116
through-setting heawy duty anchors
Vorpa VSA heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete
Cracked and non-cracked concrete
Product information Characteristics • High performances through steel anchor with central bush and anti-rotation system
Installation • Through-setting anchor Suggestion for use • Choose the most suitable accessory in relation to the application to carry out • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
Benefits • When the hexagon nut or screw is tightened, the cone is pulled into the expansion sleeve and expands tensioning it against the hole wall • Smooth expansion thanks to the three cuts on the expansion body • High tensile loads with standard depth • High shear resistances, applications are possible with minimim centre to centre and edge distance • The red ring collar prevents the anchor turning in the hole on installation • Regular grip on the base material thanks to the expansion shell • Fixing in seismic C1 in progress • Approved for cracked and non-cracked concrete
Installation sequence
Technical data
VSA V with 8.8 hexagonal head screw
Code
Description
Lt mm
for screw d x Lv mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Ch
10880 10881 10882 10883 10884 10885 10886 10887 10888 10889 10890 * 10891 *
VSA V 12/10-80 VSA V 12/20-90 VSA V 12/50-120 VSA V 15/10-90 VSA V 15/20-100 VSA V 15/50-130 VSA V 18/10-110 VSA V 18/25-125 VSA V 18/50-150 VSA V 18/100-200 VSA V 24/25-140 VSA V 24/50-165
80 90 120 90 100 130 110 125 150 200 140 165
M8x80 M8x90 M8x120 M10x90 M10x100 M10x130 M12x120 M12x130 M12x160 M12x200 M16x 140 M16x 170
12 12 12 15 15 15 18 18 18 18 24 24
85 85 85 95 95 95 120 120 120 120 130 130
10 20 50 10 20 50 10 25 50 100 25 50
25 25 25 50 50 50 80 80 80 80 150 150
13 13 13 17 17 17 19 19 19 19 24 24
* Not included in C1 fixing in seismic
117
h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness Tinst = Torque Ch = Spanner
through-setting heawy duty anchors
Vorpa VSA heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete
Cracked and non-cracked concrete
dati tecnici
VSA B with stud and nut
Code
Description
Lt mm
for screws d x Lb mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Ch
10900 10901 10902 10903 10904 10905 10906 10907 10908 10909 10910 * 10911 *
VSA B 12/10-80 VSA B 12/20-90 VSA B 12/50-120 VSA B 15/10-90 VSA B 15/20-100 VSA B 15/50-130 VSA B 18/10-110 VSA B 18/25-125 VSA B 18/50-150 VSA B 18/100-200 VSA B 24/25-140 VSA B 24/50-165
80 90 120 90 100 130 110 125 150 200 140 165
M8x92 M8x102 M8x132 M10x105 M10x115 M10x145 M12x135 M12x150 M12x180 M12x220 M16x165 M16x190
12 12 12 15 15 15 18 18 18 18 24 24
85 85 85 95 95 95 120 120 120 120 130 130
10 20 50 10 20 50 10 25 50 100 25 50
25 25 25 50 50 50 80 80 80 80 150 150
13 13 13 17 17 17 19 19 19 19 24 24
h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness Tinst = Torque Ch = Spanner Lb = Stud length
* Not included in C1 fixing in seismic
VSA S with 10.9 flat countersunk head
Code
Description
Lt mm
for screws d x Lv mm
d0 mm
h1 mm
Tfix max mm
Tinst Nm
10920 10921 10922 10923 10924 10925 10926 10927 10928
VSA S 12/16-85 VSA S 12/26-95 VSA S 12/56-125 VSA S 15/15-95 VSA S 15/25-105 VSA S 15/55-135 VSA S 18/18-120 VSA S 18/33-135 VSA S 18/58-160
85 95 125 95 105 135 120 135 160
M8x80 M8x90 M8x130 M10x100 M10x110 M10x140 M12x120 M12x140 M12x170
12 12 15 15 15 15 18 18 18
85 85 95 95 95 95 120 120 120
16 26 56 15 25 55 18 33 58
25 25 50 50 50 50 80 80 80
118
h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness Tinst = Torque Ch = Spanner Lb = Stud length
through-setting heawy duty anchors
Vorpa VSA heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete
Cracked and non-cracked concrete
Installation data Anchor type Installation data Anchor diameter Anchor length Effective anchorage depth Fixture thickness Drill hole diameter Drill hole depth Hole diameter in the fixture Torque moment
VSA-V/VSA-B M8 VSA-V/VSA-B M10 VSA-V/VSA-B M12 VSA-V/VSA-BM16 d L hef Tfix d0 h1 df Tinst
mm mm mm mm mm mm mm Nm
12 80-90-110 59 10-20-50 12 85 14 25
15 90-100-130 67 10-20-50 15 95 17 50
18 110-125-150-200 88 10-25-50-100 18 120 20 80
24 140-165 99 25-50 24 130 26 150
Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum thickness member
Scr,N Ccr,N Smin Cmin hmin
mm mm mm mm mm
250 200 120 80 125
290 220 140 90 13
390 260 180 110 190
420 280 240 130 220
VSA-S M8
VSA-S M10
VSA-S M12
Anchor type Installation data Anchor diameter Anchor length Effective anchorage depth Fixture thickness Drill hole diameter Drill hole depth Hole diameter in the fixture Torque moment
d L hef Tfix d0 h1 df Tinst
mm mm mm mm mm mm mm Nm
12 86-96-126 59 16-26-56 12 85 14 25
15 95-105-135 67 15-25-55 15 95 17 50
18 120-135-160 88 18-33-58 18 120 20 80
Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum thickness member
Scr,N Ccr,N Smin Cmin hmin
mm mm mm mm mm
250 200 120 80 125
290 220 140 90 13
390 260 180 110 190
Ø12
Ø15
Ø18
Ø24
Characteristic values Pull out failure Non-cracked concrete Cracked concrete C30/37 C40/50 C50/60
Nrk,P C20/25 Nrk,P C20/25 Ψ 30/37 Ψ 40/50 Ψ 50/60
KN KN -
12 7 1,22 1,41 1,55
16 10 1,22 1,41 1,55
25 18 1,22 1,41 1,55
40 28 1,22 1,41 1,55
VRk,S MRK,S
KN Nm
16,8 30
25 60
33,7 105
62,8 266
Values where the reduction factor is included Pull out failure Nrk,P Non-cracked concrete Nrk,P Cracked concrete Vrk Shear failure Mrk Bending moment
KN KN KN Nm
10 5,8 13,4 24
13,3 8,3 20 48
20,8 15 26,9 84
33,3 23,3 50,2 212,8
Design load with safety factor included Pull out failure Non-cracked concrete Cracked concrete Shear failure Bending moment
KN KN KN Nm
7,1 4,1 9,5 17,1
9,5 5,9 14,2 34,2
14,8 10,7 19,2 60
23,7 16,6 35,8 152
Shear failure Bending moment
N N V M
119
through-setting heawy duty anchors
Vorpa VSP
Steel anchors with ETA option 7 for non-cracked concrete
Non-cracked concrete
Products group VSP V [*] with 8.8 hexagonal head screw
Suitable to fix • Parapets • Steel beams • Machine tools • Industrial systems • Heavy duty metal constructions
Approved for • Non-cracked concrete Also suitable for • Natural stone • Concrete C12/C15
VSP B [*] with stud and nut
VSP S with 10.9 flat countersunk head
[*] VSP D with blind nut
European Technical Approval Option 7 for non-cracked concrete
As it can also be used on concrete with different strength characteristics, as specified in ETA, on compact natural stone and others materials (exception not included in ETA), specific on-site tests by the user are necessary
Examples of applications
120
Software Vorpa Calcul Anchor
through-setting heawy duty anchors
Vorpa VSP
Steel anchors with ETA option 7 for non-cracked concrete
Non-cracked concrete
Product information Characteristics • High performances through steel anchor with central bush and anti-rotation system • When the hexagon nut or screw is tightened, the cone is pulled into the expansion sleeve and expands tensioning it against the hole wall. Benefits • Smooth expansion thanks to the three cuts on the expansion body • High tensile loads with standard depth • High shear resistances, applications are possible with minimin centre to centre and edge distance • The red ring collar prevents the anchor turning in the hole on installation • Regular grip on the base material thanks to the expansion shell
Installation • Through-setting anchor Suggestion for use • Choose the most suitable accessory in relation to the application to carry out • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
Installation sequence
Technical data
VSP V with 8.8 hexagonal head screw
Code
8860 8861 8862 8864 8865 8866 8868 8869 8870 8872 8873 8874 8875 8877 8878
Description
Lt mm
for screws d x Lv mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Ch
VSP V 10/10-70 VSP V 10/20-80 VSP V 10/50-110 VSP V 12/10-80 VSP V 12/20-90 VSP V 12/50-120 VSP V 15/10-90 VSP V 15/20-100 VSP V 15/50-130 VSP V 18/10-110 VSP V 18/25-125 VSP V 18/50-150 VSP V 18/100-200 VSP V 24/25-140 VSP V 24/50-165
70 80 110 80 90 120 90 100 130 110 125 150 200 140 165
M6x70 M6x80 M6x110 M8x80 M8x90 M8x120 M10x90 M10x100 M10x130 M12x120 M12x130 M12x160 M12x200 M16x 140 M16x 170
10 10 10 12 12 12 15 15 15 18 18 18 18 24 24
75 75 75 85 85 85 95 95 95 120 120 120 120 130 130
10 20 50 10 20 50 10 20 50 10 25 50 100 25 50
10 10 10 25 25 25 50 50 50 80 80 80 80 150 150
10 10 10 13 13 13 17 17 17 19 19 19 19 24 24
121
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length
through-setting heawy duty anchors
Vorpa VSP
Steel anchors with ETA option 7 for non-cracked concrete
Non-cracked concrete
Technical data
VSP B with stud and nut
Code
9860 9861 9862 9864 9865 9866 9868 9869 9870 9872 9873 9874 9875 9877 9878
Description
Lt mm
for screws d x Lb mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Ch
VSP B 10/10-70 VSP B 10/20-80 VSP B 10/50-110 VSP B 12/10-80 VSP B 12/20-90 VSP B 12/50-120 VSP B 15/10-90 VSP B 15/20-100 VSP B 15/50-130 VSP B 18/10-110 VSP B 18/25-125 VSP B 18/50-150 VSP B 18/100-200 VSP B 24/25-140 VSP B 24/50-165
70 80 110 80 90 120 90 100 130 110 125 150 200 140 165
M6x80 M6x90 M6x120 M8x92 M8x102 M8x132 M10x105 M10x115 M10x145 M12x135 M12x150 M12x180 M12x220 M16x165 M16x190
10 10 10 12 12 12 15 15 15 18 18 18 18 24 24
75 75 75 85 85 85 95 95 95 120 120 120 120 130 130
10 20 50 10 20 50 10 20 50 10 25 50 100 25 50
10 10 10 25 25 25 50 50 50 80 80 80 80 150 150
10 10 10 13 13 13 17 17 17 19 19 19 19 24 24
VSP S with 10.9 flat countersunk head
Code
Description
Lt mm
for screws d x Lv mm
d0 mm
h1 mm
Tfix max mm
Tinst Nm
Ch
11875 11876 11877 11878
VSP S 12/10-80 VSP S 12/50-120 VSP S 15/10-90 VSP S 15/50-130
80 120 90 130
M8x90 M8x130 M10x100 M10x140
12 12 15 15
85 85 95 95
10 50 10 50
25 25 50 50
13 13 17 17
VSP D with stud and nut
Code
Description
Lt mm
for screws d x Lb mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Ch
10860 10861 10862 10864 10865 10866 10868 10869 10870 10872 10873 10874 10875 10877 10878
VSP D 10/10-70 VSP D 10/20-80 VSP D 10/50-110 VSP D 12/10-80 VSP D 12/20-90 VSP D 12/50-120 VSP D 15/10-90 VSP D 15/20-100 VSP D 15/50-130 VSP D 18/10-110 VSP D 18/25-125 VSP D 18/50-150 VSP D 18/100-200 VSP D 24/25-140 VSP D 24/50-165
70 80 110 80 90 120 90 100 130 110 125 150 200 140 165
M6x80 M6x90 M6x120 M8x92 M8x102 M8x132 M10x105 M10x115 M10x145 M12x135 M12x150 M12x180 M12x220 M16x165 M16x190
10 10 10 12 12 12 15 15 15 18 18 18 18 24 24
75 75 75 85 85 85 95 95 95 120 120 120 120 130 130
10 20 50 10 20 50 10 20 50 10 25 50 100 25 50
10 10 10 25 25 25 50 50 50 80 80 80 80 130 130
10 10 10 13 13 13 17 17 17 19 19 19 19 24 24
122
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length
through-setting heawy duty anchors
Vorpa VSP
Steel anchors with ETA option 7 for non-cracked concrete
Non-cracked concrete
Installation data VSP10 M6
VSP12 M8
VSP15 M10
VSP18 M12
VSP24 M16
mm mm mm mm mm mm mm Nm
10 70-80-110 49 10-20-50 10 75 12 10
12 80-90-110 59 10-20-50 12 85 14 25
15 90-100-130 67 10-20-50 15 95 17 50
18 110-125-150-200 88 10-25-50-100 18 120 20 80
24 140-165 99 25-50 24 130 26 150
Scr,N Ccr,N Smin Cmin hmin
mm mm mm mm mm
210 140 100 70 100
250 200 120 80 125
290 220 140 90 13
390 260 180 110 190
420 280 240 130 220
Nrk,P C20/25
KN
9 1,22 1,41 1,55
12 1,22 1,41 1,55
16 1,22 1,41 1,55
25 1,22 1,41 1,55
40 1,22 1,41 1,55
VRk,S C20/25 MRK,S
KN Nm
8 12
14,6 30
23,2 60
33,7 105
62,8 266
Values where the reduction factor γ is included (Design loads) Nrk,P Pull out failure KN VRk,S Shear failure KN MRK,S Bending moment Nm
6 6,4 9,6
6,7 11,7 24
8,9 18,6 48
16,7 27 84
22,2 50,2 212,8
Recommended loads Pull out failure Shear failure Bending moment
4,2 4,6 6,8
4,8 8,3 17
6,3 13,2 34,3
11,9 19,3 60
15,8 35,8 152
Anchor type Installation data Anchor diameter Anchor length Effective anchorage depth Fixture thickness Drill hole diameter Drill hole depth Hole diameter in the fixture Torque moment
d L hef Tfix d0 h1 df Tinst
Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum thickness member Characteristic values Pull out failure Ψc C30 Ψc C40 Ψc C50 Shear failure Bending moment
KN KN Nm
123
through-setting heawy duty anchors
Vorpa VSX Steel anchors
Concrete
Products group VSX with blind nut
Suitable for • Concrete
VSX INOX A2 with blind nut
Suitable to fix • Parapets • Steel beams • Machine tools • Industrial systems • Heavy duty metal constructions • Industrial signals
Software Vorpa Calcul Anchor
Examples of applications
Product information Characteristics • High performances through steel anchor with central bush and anti-rotation system Benefits • Reduced hole diameter granting a better capacity • Smooth expansion thanks to the three cuts on the expansion body • The red collar prevents the anchor turning in the hole on installation
Installation • Through-setting anchor Suggestion for use • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
Installation sequence
124
through-setting heawy duty anchors
Vorpa VSX Steel anchors
Concrete
Technical data
VSX with blind nut
Code
959 958 960 961 962 963 964 965 967 966
Description
Lt mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Ch
VSX 8/15-70 VSX 8/30-85 VSX 10/15-85 VSX 10/50-120 VSX 12/15-100 VSX 12/50-135 VSX 14/20-115 VSX 14/50-145 VSX 16/20-130 VSX 16/40-150
65 80 75 110 85 120 100 130 110 130
8 8 10 10 12 12 14 14 16 16
55 55 65 65 75 75 85 85 95 95
15 30 15 50 15 50 20 50 20 40
6 6 10 10 25 25 50 50 85 85
13 13 17 17 19 19 22 22 24 24
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length
VSX inox A2 with blind nut (A2 Stainless Steel) Code
3959 3958 3960 3961 3962 3963
Description
Lt mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Ch
VSX A2 8/15-70 VSX A2 8/30-85 VSX A2 10/15-85 VSX A2 10/50-120 VSX A2 12/15-100 VSX A2 12/50-135
65 80 75 110 85 120
8 8 10 10 12 12
55 55 65 65 75 75
15 30 15 50 15 50
6 6 10 10 25 25
13 13 17 17 19 19
Installation data
VSX Anchor Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness
Scr Ccr Smin Cmin hmin
mm mm mm mm mm
VSX 8/M5 180 90 90 50 150
VSX 10/M6 220 110 130 70 150
VSX 12/M8 VSX 10/M10 VSX 16/M12 280 400 450 140 170 200 170 230 270 90 110 140 200 200 250
Permissible loads - applications in concrete C20/25 VSX - VSX A2 - - -
daN
1 daN â&#x2030;&#x192;1 kg 250
350
470
600
700
Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.
125
through-setting heawy duty anchors
Vorpa CSB CE+SEISMIC Steel safety screw for cracked concrete and seismic zone Steel screw fixings with Eta Option 1 for cracked and non cracked concrete
Cracked and non cracked concrete
Products group CSB CE [*] with hexagonal head
Approved for • Cracked and non cracked concrete Ø8-Ø16 • Seismic applications TR045 categ. C1-C2: Ø12 - Ø16, categ. C1: Ø10 • Anchorage under fire exposure in standard TR 020 R30-R120
CSB with mushroom head Torx recess
CSB E CE [*] with hexagonal stud and nut
Also suitable for • Natural stone • Concrete C12/C15
CSB S CE [*] with countersunk head Torx recess
To fix • Parapets • Steel beams • Machine tools • Industrial systems • Heavy duty metal constructions • Structural fixings • Profiles • Pipes • Plants engineering • Railings • Gates • Window and door frames
As it can also be used on concrete with different strength characteristics, as specified in ETA, on compact natural stone and others materials (exception not included in ETA), specific on-site tests by the user are necessary
European Technical Assesment EAD 330323-00-0601 ANNEX E Option 1 - Cracked and non cracked concrete Seismic fixings - category C1-C2 annex E - TR045
R30-R120
Annex E -
C1-C2
Examples of applications
Product information Characteristics • Steel screw fixing with special dual lead thread design • When the concrete screw is screwed into the hole, the thread taps into the concrete and creates a positive fit anchorage • Certified ETA-CE option1 and performance category C1-C2 under seismic action
Benefits • Suitable for use in compression resistant natural stone (without approval) • Approved under the building regulations with a new European Technical Assessment (Option 1) • Approved for use in cracked and non-cracked concrete
Benefits • Reduced hole diameter • Vibrations resistance, easy to identify by the screw’s head • Ideal for permanent and removable fixing both inside and outside • Virtually expansion-free operation allows cost-efficient fixing with small axial spacing and edge distances. • Fire tested in compliance with DIN 4102-2. Fire resistance ratings R30–R120 • Approved for use under seismic loading, performance categories c1-c2
Installation • Through-setting anchor Suggestion for use • Choose the most suitable accessory in relation the application to carry out • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
126
through-setting heawy duty anchors
Vorpa CSB CE+SEISMIC Steel safety screw for cracked concrete and seismic zone Steel screw fixings with Eta Option 1 for cracked and non cracked concrete
Cracked and non cracked concrete
Installation sequence
Technical data
CSB CE with hexagonal head
Code
Description
93672 93673 93674 93676 93677 93678 93679 93680 93681 93682 93683 93684 93685 93686 93687 93688 93689 93690 93691
CSB CE 8x80 CSB CE 8x100 CSB CE 8x120 CSB CE 10x80 CSB CE 10x100 CSB CE 10x120 CSB CE 10x140 CSB CE 10x160 CSB CE 12x90 CSB CE 12x110 CSB CE 12x130 CSB CE 12x150 CSB CE 12x190 CSB CE 12x210 CSB CE 12x250 CSB CE 12x290 CSB CE 16x130 CSB CE 16x150 CSB CE 16x180
dv x Lv mm
tfix mm
8 x 80 8 x 100 8 x 120 10 x 80 10 x 100 10 x 120 10 x 140 10 x 160 12 x 90 12 x 110 12 x 130 12 x 150 12 x 190 12 x 210 12 x 250 12 x 290 12 x 130 16 x 150 16 x 180
20 40 60 10 30 50 70 90 10 30 50 70 110 130 170 210 20 40 70
d0 mm
6 6 6 8 8 8 8 8 10 10 10 10 10 10 10 10 14 14 14
h1 mm
hmin mm
hnom mm
hef mm
tinst Nm
Ch
Cmin mm
Smin mm
75 75 75 85 85 85 85 85 100 100 100 100 100 100 100 100 140 140 140
100 100 100 110 110 110 110 110 130 130 130 130 130 130 130 130 170 170 170
60 60 60 70 70 70 70 70 80 80 80 80 80 80 80 80 110 110 110
48 48 48 56 56 56 56 56 64 64 64 64 64 64 64 64 85 85 85
20 20 20 50 50 50 50 50 80 80 80 80 80 80 80 80 160 160 160
10 10 10 13 13 13 13 13 15 15 15 15 15 15 15 15 21 21 21
45 45 45 50 50 50 50 50 60 60 60 60 60 60 60 60 80 80 80
45 45 45 50 50 50 50 50 60 60 60 60 60 60 60 60 80 80 80
h1 = Minimum depth of drill hole Lv = Screw length d0 = Drill hole diameter dv = Screw diameter df = Diameter of clearance hole in the fixture tfix = Maximum thickness of fixture tinst = Required torque moment Ch = Spanner hmin = Minimum thickness of concrete member hnom = Overall anchor embedment depth hef = Effective anchorage depth T = 6 lobe recess Cmin = Minimum allowable edge distance Smin = Minimum allowable spacing Ccr = Edge distance for ensuring the transmission of the characteristic resistance of a single anchor Scr = Spacing for ensuring the transmission of the characteristic resistance of a single anchor
CSB with mushroom head Torx recess
Code
Description
3381 3383 4379 93735 93736 93738 93739
CSB B 8x60 CSB B 8x80 CSB B 8x100 CSB B 10x60 CSB B 10x80 CSB B 10x100 CSB B 10x120
dv x Lv mm
8 x 60 8 x 80 8 x 100 10 x 60 10 x 80 10 x 100 10 x 120
tfix mm
10 20 40 10 10 30 50
d0 mm
6 6 6 8 8 8 8
h1 mm
65 75 75 70 90 90 90
hmin mm
hnom mm
hef mm
df mm
100 110 110 100 130 130 130
50 60 60 50 70 70 70
45 55 55 45 65 65 65
9 9 9 12 12 12 12
tinst Nm
20 20 20 50 50 50 50
T
Cmin mm
Smin mm
Ccr mm
Scr Characteristic loads (kN) mm Pull out Shear
T30 T30 T30 T40 T40 T40 T40
45 45 45 55 55 55 55
45 45 45 55 55 55 55
75 90 90 75 105 105 105
150 180 180 150 210 210 210
7,6 11,2 11,2 9,2 15,6 15,6 15,6
14,1 14,1 14,1 23,4 23,4 23,4 23,4
Pull-out and shear showed in the table are CHARACTERISTIC LOADS from tests run on non-cracked concrete C20/25 without edge and spacing effect (Pull-out and shear loads are in kN: 1kN = 100kg).
127
through-setting heawy duty anchors
Vorpa CSB CE+SEISMIC Steel safety screw for cracked concrete and seismic zone Steel screw fixings with Eta Option 1 for cracked and non cracked concrete
Cracked and non cracked concrete
Technical data
CSB CE with hexagonal stud and nut
Code
Description
93710 93711 93713 93725 93726 93727 93728
CSB E CE 8x90 CSB E CE 8x120 CSB E CE 10x105 CSB E CE 10x125 CSB E CE 10x195 CSB E CE 12x118 CSB E CE 12x138
dv x Lv mm
tfix mm
8 x 90 8 x 120 10 x 105 10 x 125 10 x 195 12 x 118 12 x 138
10 40 10 30 100 10 30
d0 mm
6 6 8 8 8 10 10
h1 mm
hmin mm
hnom mm
hef mm
75 75 90 90 90 100 100
100 100 110 110 110 130 130
60 60 70 70 70 80 80
48 48 56 56 56 64 64
tinst Nm
20 20 50 50 50 80 80
Ch
Cmin mm
Smin mm
5 5 7 7 7 8 8
45 45 50 50 50 60 60
45 45 50 50 50 60 60
Ch
Cmin mm
Smin mm
T30 T30 T30 T40 T40 T40 T50 T50
45 45 45 50 50 50 60 60
45 45 45 50 50 50 60 60
CSB CE with countersunk head Torx recess
dv x Lv mm
Code
Description
93700 93701 93702 93703 93704 93705 93706 93707
CSB S CE 8x70 CSB S CE 8x100 CSB S CE 8x140 CSB S CE 10x80 CSB S CE 10x100 CSB S CE 10x160 CSB S CE 12x100 CSB S CE 12x120
8 x 70 8 x 100 8 x 140 10 x 80 10 x 100 10 x 160 12 x 100 12 x 120
tfix mm
d0 mm
10 40 80 10 30 90 20 40
6 6 6 8 8 8 10 10
h1 mm
hmin mm
hnom mm
hef mm
75 75 75 90 90 90 100 100
100 100 100 110 110 110 130 130
60 60 60 70 70 70 80 80
48 48 48 56 56 56 64 64
tinst Nm
20 20 20 50 50 50 80 80
Installation data Characteristic Values CSB - CSB E - CSBS Pull out Pull out Pull out Pull out Ψc C30/37 Ψc C40/50 Ψc C50/60 Shear failure Shear failure Shear failure Bending moment
NRKP NRKP NRKP, p, eq NRKP, p, eq
C20/25 (non-cracked) C20/25 (cracked) Cat. C1 Cat. C2
[kN] [kN] [kN] [kN]
Ø8
Ø10
Ø12
Ø16
16 4 -
20 7,5 6 -
25 9 6,3 2,7
40 16 16 7,2
1,22 1,41 1,55 VRKS VRKS, s, eq VRKS, s, eq MRKS
[kN] [kN] [kN] [kN]
9,4 19
20,1 12,1 44
32,4 19,1 17,7 83
56,9 39,8 39,8 216
Values with reduction factor (design loads) NRKP Pull out C20/25 (non-cracked) NRKP Pull out C20/25 (cracked) NRKP, p, eq Cat. C1 Pull out NRKP, p, eq Cat. C2 Pull out VRKS Shear failure MRKS Bending moment
[kN] [kN] [kN] [kN] [kN] [kN]
11,4 2,8 6,2 12,6
16,6 6,2 5 13,4 29,3
17,8 6,4 4,5 1,9 21,6 55,3
28,5 11,4 11,4 5,1 37,9 144
Recommended loads Pull out Pull out Pull out Pull out Shear failure Bending moment
[kN] [kN] [kN] [kN] [kN] [kN]
8,1 2 4,4 9
11,8 4,4 3,5 9,5 20
12,7 4,5 3,2 1,3 15,4 39,5
20,3 8,1 8,1 3,6 27 102
N N N N V M
Cat. C1 Cat. C2
(non-cracked) (cracked) Cat. C1 Cat. C2
128
pre-setting heavy duty anchors
Vorpa VA Steel anchors
Non-cracked concrete
Products group ETA version approved for • Non-cracked concrete C20/25 - C50/60 - M6-M16 • Multiple use for non structural applications on non-cracked concrete C20/25 - C50/60 - M6-M16
VA CE [*] with internal thread
VA with internal thread VA INOX A4 (A4 stainless steel) internal thread
To fix • Railings • Plants engineering • Beams • Sections • Ventilation systems and ceiling heating systems • Ceiling lighting
All versions • Non cracked concrete C20/25 C50/60 • Natural stone
VA F CE lipped type
[*]
VA F lipped type European Technical Approval Option 7 for non-cracked concrete
PERNO VA Impacting tool
Multiple use in non-cracked concrete for non structural applications
As it can also be used on concrete with different strength characteristics, as specified in ETA, on compact natural stone and others materials (exception not included in ETA), specific on-site tests by the user are necessary
Examples of applications
Product information Characteristics • Steel anchor with internal thread and internal expansion cone to be used with bolts or threaded bars. • When the cone is driven in with the apposite impacting tool, the anchor sleeve is spread and thus expands against the hole wall. Benefits • Easy application and quick and safe installation thanks to the proper impacting tool • The collar of the lipped type avoid the slipping of the anchor inside the hole • Suitable for bars and accessories with metrical thread • Possibility of inserting the anchor through the object to be fixed • Low anchorage depth reduces drilling time and thus cost- efficient installation
Benefits • Surface-flush anchor allows the attached items to be removed and refitted several times. Installation • Pre-setting anchor • Through-setting only in the version VA Suggestion for use • Choose the most suitable type in relation to the application to carry out • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
129
pre-setting heavy duty anchors
Vorpa VA Steel anchors
Non-cracked concrete
Installation sequence
Technical data VA.CE
Code
Description
99591 99594 99592 99593
VA.CE 8x30 VA.CE 8x40 VA.CE 10x40 VA.CE 12x50
Lt mm
d0 mm
h1 mm
for screws Ø mm
internal thread L mm
30 40 40 50
10 10 12 15
30 40 40 50
M8 M8 M10 M12
13 20 15 18 Screw length calculation: Lv = Lt + tfix
VA. F CE
Code
Description
98590 98591 98592 98593 98594
VA F CE 8x30 VA F CE 8x40 VA F CE 10x30 VA F CE 10x40 VA F CE 12x50
Lt mm
d0 mm
h1 mm
for screws Ø mm
internal thread L mm
30 40 30 40 50
8 8 10 10 12
30 40 30 40 50
M8 M8 M10 M10 M12
13 20 12 15 18
Installation data Anchor type Installation data VA CE / VA F CE Anchor diameter Anchor length Effective anchorage depth Drill hole diameter Drill hole depth Hole diameter in the fixture Torque moment Critical axial spacing Critical edge distance Minimum thickness member
M8
M10
M12
Tinst ≤
mm mm mm mm mm mm Nm
10 30 30 10 30 9 8
12 40 40 12 40 12 15
15 50 50 15 50 14 35
Scr,N Ccr,N hmin
mm mm mm
90 45 100
120 60 120
150 75 130
d L hef d0 h1 df
Characteristic values application in concrete non-cracked C20/25 11,3/13,5 Pull out failure Nrk,P C20/25 KN 1,22 Ψc C30/37 1,41 Ψc C40/50 1,55 Ψc C50/60
16,9 1,22 1,41 1,55
1 daN ≃1 kg 24,1 1,22 1,41 1,55
Design loads VA CE / VA F CE Pull out failure
N
KN
3,3/3,6
5,1
1 daN ≃1 kg 7,1
Recommended loads VA CE / VA F CE Pull out failure N
KN
2,3/2,5
3,6
1 daN ≃1 kg 5
130
h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
pre-setting heavy duty anchors
Vorpa VA Steel anchors
Non-cracked concrete
Technical data
VA
Code
590 591 592 593 594 595
7590 7591 7592 7593 7594 7595
VA A4
Description
Lt mm
internal thread L mm
for screws Ø mm
d0 mm
VA 6 VA 8 VA 10 VA 12 VA 16 VA 20
25 30 40 50 65 80
12 13 15 18 23 34
M6 M8 M10 M12 M16 M20
8 10 12 15 20 25
30 35 45 55 70 85
4 8 15 35 60 120
VA A4 VA A4 VA A4 VA A4 VA A4 VA A4
25 30 40 50 65 80
12 13 15 18 23 34
M6 M8 M10 M12 M16 M20
8 10 12 15 20 25
30 35 45 55 70 85
4 8 15 35 60 120
Lt mm
internal thread L mm
for screws Ø mm
d0 mm
25 30 30 40 50 50 65 80
12 13 15 25 18 18 23 34
M6 M8 M10 M10 M12 M12 M16 M20
8 10 12 12 15 16 20 25
6 8 10 12 16 20
h1 mm
Tinst Nm
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
VA F
Code
Description
8590 8591 8592A 8592B 8593 8592 8594 8595
VA F VA F VA F VA F VA F VA F VA F VA F
Code
Description
295 296 298 299 300 1303
6 8 10/30 10/40 12Ø15 12Ø16 16 20
PERNO VA PERNO VA PERNO VA PERNO VA PERNO VA PERNO VA
h1 mm
Tinst Nm
30 35 35 45 55 55 70 85
4 8 15 15 35 35 60 120
for thread VA mm
6 8 10 12 16 20
M6 M8 M10 M12 M16 M20
Scr Ccr hmin
mm mm mm
M6 220 105 170
M8 260 130 170
M10 340 170 220
M12 420 210 220
Permissible loads - applications in concrete C20/25 VA - VA A4 - VA F - - -
N
daN
M16 530 265 245
M20 670 340 330
1 daN ≃1 kg 85
h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
Impacting tool for VA anchors
Installation data VA Anchor Critical axial spacing Critical edge distance Minimum structural thickness
Screw length calculation: Lv = Lt + tfix
160
400
600
790
1400
Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.
131
pre-setting heavy duty anchors
Vorpa TOP
Steel anchors with ETA option 7 (CE marking) for non-cracked concrete
Non-cracked concrete
Natural stone
Solid brick
Products group TOP [*] no accessories
TOP BU [*] with 8.8 hexagonal head screw
TOP BP [*] through-setting with 8.8 hexagonal head screw and spacer
To fix • Steel structures • Windows and door frames • Railings and balustrades • Gates All versions • Façades • Natural stone • Machineries • Solid brick • Non cracked concrete C12/15 • Iron bars C50/60 ETA version approved for • Non-cracked concrete C20/25 - C50/60 - M6-M16
[*] European Technical Approval Option 7 for non-cracked concrete
TOP BD with stud
TOP OS with eyebolt
TOP OP with eyebolt and spacer
TOP GS with hook-bolt
Option 7 for non-cracked concrete
Software Vorpa Calcul Anchor
As it can also be used on concrete with different strength characteristics, as specified in ETA, on compact natural stone and others materials (exception not included in ETA), specific on-site tests by the user are necessary Examples of applications
TOP TS through-setting with 10.9 countersunk head screw TOP DC through-setting with blind nut TOP INOX A2 TOP INOX A4 [*] no accessories TOP INOX A2 BU TOP INOX A4 BU [*] with hexagonal head screw TOP OS INOX A2 with eyebolt TOP GS INOX A2 with hook-bolt TOP INOX A2 BD TOP INOX A4 BD with threaded stud
TOP BD PROL. A2 with threaded stud
132
pre-setting heavy duty anchors
Vorpa TOP
Steel anchors with ETA option 7 (CE marking) for non-cracked concrete
Non-cracked concrete
Natural stone
Solid brick
Product information Characteristics • Torque controlled expansion anchor made of galvanized steel or stainless steel composed of anti-rotation cold formed body, expansion conical nut and accessory. • When the bolt or hexagon nut is tightened, the cone is pulled into the expansion sleeve and expands it against the hole wall.
Benefits • Three-part expansion sleeve allows even load distribution and small edge and axial spacing. Installation • Pre-setting anchor • Through-setting only in the version TOP BP and TOP TS
Benefits • Wide range of accessories • Anti-rotation during the installation procedure • Suitable for all bolts or studs with metric thread • Fixing can be casily driven in, therefore less installation effort • Surface-flush fixing allows the mounted item to be removed and refitted several times • Anchor version with internal thread for high flexibility by using threaded rods or screws of different lengths and type
Suggestion for use • Choose the most suitable accessory in relation to the application to carry out • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
Installation sequence
Pre-setting anchor TOP
Through-setting anchor TOP
Technical data TOP no accessories
Code
710 711 712 713
Description
Lt mm
for screws Ø mm
d0 mm
h1 mm
TOP 6 TOP 8 TOP 10 TOP 12
45 51 60 75
M6 M8 M10 M12
10 12 14 18
55 60 70 85
TOP BU with 8.8 hexagonal head screw
Code
720 721 722 723
Description
Lt mm
for screws d x Lv mm
d0 mm
h1 mm
Tfix max mm
Tinst Nm
Ch
TOP 6 BU TOP 8 BU TOP 10 BU TOP 12 BU
45 51 60 75
M6x55 M8x65 M10x80 M12x100
10 12 14 18
55 60 70 85
10 14 20 25
10 25 40 75
10 13 17 19
133
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length
pre-setting heavy duty anchors
Vorpa TOP
Steel anchors with ETA option 7 (CE marking) for non-cracked concrete
Non-cracked concrete
Technical data TOP BP through-setting with 8.8 hexagonal head screew and spacer Code
2720 2721 2722 2723
Description
Lt mm
for screws d x Lv mm
d0 mm
h1 mm
Tfix max mm
Tinst Nm
Ch
TOP 6 BP TOP 8 BP TOP 10 BP TOP 12 BP
45 51 60 75
M6x80 M8x90 M10x100 M12x120
10 12 14 18
55 60 70 85
30 35 38 43
10 25 40 75
10 13 17 19
TOP BD with stud
Code
705 706 707 708
Description
Lt mm
for screws d x Lb mm
d0 mm
h1 mm
Tfix max mm
Tinst Nm
Ch
TOP 6 BD 57 TOP 8 BD 75 TOP 10 BD 90 TOP 12 BD 110
45 51 60 75
M6x57 M8x75 M10x90 M12x110
10 12 14 18
55 60 70 85
10 10 20 25
6 15 30 50
10 13 17 19
TOP OS with eyebolt
Code
795 796 797 798
Description
Lt mm
for screws d x L0 mm
d0 mm
h1 mm
Tinst Nm
Ø
TOP 6 OS TOP 8 OS TOP 10 OS TOP 12 OS
45 51 60 75
M6x55 M8x60 M10x73 M12x90
10 12 14 18
55 60 70 85
5 12 20 35
10±0,5 11,8±0,5 14,5±0,5 17±0,5
TOP OP through-setting with spacer and eyebolt
Code
Description
2572 TOP 10 OP
Lt mm
eyebolt d x L0 mm
d0 mm
h1 mm
Tinst Nm
Ø
60
M10x100
14
90
20
14,5
TOP GS with hook-bolt
Code
775 776 777 778
Description
Lt mm
hook bolt d x Lg mm
d0 mm
h1 mm
Tinst Nm
P
TOP 6 GS TOP 8 GS TOP 10 GS TOP 12 GS
45 51 60 75
M6x55 M8x60 M10x73 M12x90
10 12 14 18
55 60 70 85
5 12 20 35
8±0,5 10±0,5 12,5±0,5 16±0,5
134
Natural stone
Solid brick
pre-setting heavy duty anchors
Vorpa TOP
Steel anchors with ETA option 7 (CE marking) for non-cracked concrete
Non-cracked concrete
Natural stone
Technical data
TOP TS through-setting with 10.9 countersunk head screw
Code
Description
Lt mm
screws d x Lv mm
d0 mm
h1 mm
Tfix mm
Tinst Nm
Ch
11864 11866 11868 11870
TOP TOP TOP TOP
45 51 60 75
M6x80 M8x90 M10x100 M12x110
10 12 14 18
55 60 75 85
32 40 40 46
10 25 40 75
4 5 6 8
6 TS 8 TS 10 TS 12 TS
TOP DC through-setting with blind nut
Code
5720 5721 5722 5723
Description
Lt mm
screws d x Lv mm
d0 mm
h1 mm
Tfix mm
Tinst Nm
Ch
TOP 6 DC TOP 8 DC TOP 10 DC TOP 12 DC
45 51 60 75
M6x85 M8x102 M10x110 M12x135
10 12 14 18
55 60 75 85
32 40 40 46
10 25 40 75
4 5 6 8
TOP INOX A2 (A2 Stainless Steel) no accessories Code
714 715 716 717
Description
Lt mm
screws Ã&#x2DC; mm
d0 mm
h1 mm
TOP INOX A2 6 TOP INOX A2 8 TOP INOX A2 10 TOP INOX A2 12
45 51 60 75
M6 M8 M10 M12
10 12 14 18
55 60 75 85
TOP INOX A4 (A4 Stainless Steel) no accessories
3714 3715 3716 3737
TOP INOX A4 6 TOP INOX A4 8 TOP INOX A4 10 TOP INOX A4 12
45 51 60 75
Screw length calculation: Lv = Lt + tfix
M6 M8 M10 M12
10 12 14 18
55 60 75 85
TOP INOX A2 BU with hexagonal head screw (A2 Stainless Steel) Code
717 718 719 727
Description
Lt mm
screws d x Lv mm
d0 mm
h1 mm
Tfix max mm
Tinst Nm
Ch
TOP INOX A2 6 BU TOP INOX A2 8 BU TOP INOX A2 10 BU TOP INOX A2 12 BU
45 51 60 75
M6x55 M8x65 M10x80 M12x100
10 12 14 18
55 60 70 85
10 14 20 25
10 25 40 75
10 13 17 19
10 14 20 25
10 25 40 75
10 13 17 19
TOP INOX A4 BU with hexagonal head screw (A4 Stainless Steel)
3717 3718 3719 3720
TOP INOX A4 6 BU TOP INOX A4 8 BU TOP INOX A4 10 BU TOP INOX A4 12 BU
45 51 60 75
M6x55 M8x65 M10x80 M12x100
10 12 14 18
55 60 70 85
135
h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length
Solid brick
pre-setting heavy duty anchors
Vorpa TOP
Steel anchors with ETA option 7 (CE marking) for non-cracked concrete
Non-cracked concrete
Natural stone
Technical data
TOP INOX A2 GS with hook-bolt (A2 Stainless Steel) Code
3775 3776 3777 3778
Description
Lt mm
hook-bolt d x Lg mm
d0 mm
h1 mm
Tinst Nm
P
T OP INOX A2 6 GS TOP INOX A2 8 GS TOP INOX A2 10 GS TOP INOX A2 12 GS
45 51 60 75
M6x55 M8x60 M10x73 M12x90
10 12 14 18
55 60 70 85
6 15 30 50
8±0,5 10±0,5 12,5±0,5 16±0,5
TOP INOX A2 OS with eyebolt (A2 Stainless Steel) Code
3795 3796 3797 3798
Description
Lt mm
eyebolt d x L0 mm
d0 mm
h1 mm
Tinst Nm
Ø mm
TOP INOX A2 6 OS TOP INOX A2 8 OS TOP INOX A2 10 OS TOP INOX A2 12 OS
45 51 60 75
M6x55 M8x60 M10x73 M12x90
10 12 14 18
55 60 70 85
6 15 30 50
10±0,5 11,8±0,5 14,5±0,5 17±0,5
TOP INOX A2 BD with threaded stud (A2 Stainless Steel) Code
Description
25705 TOP 6 BD A2 57 25706 TOP 8 BD A2 75 25707 TOP 10 BD A2 90
Lt mm
stud d x Lb mm
d0 mm
h1 mm
Tfix max mm
Tinst Nm
Ch
45 51 60
M6x55 M8x75 M10x90
10 12 14
55 60 70
10 10 20
10 25 40
10 13 17
10 10 20
10 25 40
10 13 17
TOP INOX A4 BD with threaded stud (A4 Stainless Steel)
5705 TOP 6 BD A4 57 5706 TOP 8 BD A4 75 5707 TOP 10 BD A4 90
45 51 60
M6x55 M8x75 M10x90
10 12 14
55 60 70
L TOP BD PROL. A2 with threaded stud (A2 Stainless Steel) Code
224 225 226 227
Description
Lt mm
stud d x Lb mm
d0 mm
h1 mm
Tinst Nm
Ch
TOP 6 BD PROL. A2 L. 200 TOP 6 BD PROL. A2 L. 220 TOP 6 BD PROL. A2 L. 250 TOP 6 BD PROL. A2 L. 300
45 45 45 45
200 220 250 300
10 10 10 10
55 55 55 55
6 6 6 6
10 10 10 10
136
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length
Solid brick
pre-setting heavy duty anchors
Vorpa TOP
Steel anchors with ETA option 7 (CE marking) for non-cracked concrete
Non-cracked concrete
Technical data Anchor type Installation data TOP –TOP A4 –TOP BU – TOP BU A4 d Anchor diameter L Anchor length hef Effective anchorage depth Tfix Fixture thickness d0 Drill hole diameter h1 Drill hole depth df Hole diameter in the fixture Tinst Torque moment
M6
M8
M10
M12
mm mm mm mm mm mm mm Nm
10 45 39,5 10 10 55 7 10
12 51 44,5 14 12 60 9 25
14 60 51,5 20 14 70 12 40
18 75 63 25 18 85 14 75
Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum thickness member
Scr,N Ccr,N Smin Cmin hmin
mm mm mm mm mm
120 60 65 45 135
135 75 90 70 135
155 90 135 85 140
190 120 165 115 160
Installation data TOP BP Anchor diameter Anchor length Effective anchorage depth Fixture thickness Drill hole diameter Drill hole depth Hole diameter in the fixture Torque moment
d L hef Tfix d0 h1 df Tinst
mm mm mm mm mm mm mm Nm
10 80 40,5 30 10 55 12 10
12 90 45,5 35 12 60 14 25
14 100 48,5 38 14 70 18 40
18 120 57 43 18 85 20 75
Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum thickness member
Scr,N Ccr,N Smin Cmin hmin
mm mm mm mm mm
120 60 65 45 5
135 75 90 70 135
155 90 135 85 140
190 120 165 115 160
KN
9 1,17 1,33 1,5
12
16
20 1,22 1,41 1,55
KN Nm
8 12,2
14,6 30
23,2 59,8
33,7 104,8
KN
7,5 1,17 1,33 1,5
9
12
16 1,22 1,41 1,55
KN Nm
7 10,7
12,8 26,2
20,3 52,3
29,5 91,7
Values where the reduction factor is included TOP A4 – TOP BU A4 (Design loads) Nrk,P KN 5 Pull out failure 5 VRk,S KN 4,5 Shear failure 8,2 MRK,S Nm 6,8 Bending moment 16,8
6,6 13 33,3
8,8 18,9 58,8
Values where the reduction factor Pull out failure Shear failure Bending moment
7,6 18,5 47,8
13,3 26,9 83,8
Characteristic values TOP – TOP BU – TOP BP Nrk,P C20/25 Pull out failure ψc C30/37 ψc C40/50 ψc C50/60 Shear failure Bending moment
VRk,S C20/25 MRK,S
Characteristic values TOP A4 – TOP BU A4 Nrk,P C20/25 Pull out failure ψc C30/37 ψc C40/50 ψc C50/60 Shear failure Bending moment
VRk,S C20/25 MRK,S
is included TOP BU – TOP BP (Design loads) Nrk,P KN 5 5,7 VRk,S KN 6,4 11,6 MRK,S Nm 9,7 24
Recommended loads TOP A4 - TOP BU A4 N Pull out failure T Shear failure M Bending moment Recommended loads TOP - TOP BU - BP Pull out failure Shear failure Bending moment
KN KN Nm
3,5 3,2 4,9
3,5 5,8 12
4,7 9,3 23,8
6,3 13,5 42
KN KN Nm
3,5 4,5 6,9
4 8,3 17,1
5,4 13,2 34,1
9,5 19,2 59,8
137
Natural stone
Solid brick
pre-setting heavy duty anchors
Vorpa TOP
Steel anchors with ETA option 7 (CE marking) for non-cracked concrete
Non-cracked concrete
Installation data
Top Anchor Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness
Scr Ccr Smin Cmin hmin
mm mm mm mm mm
M6 120 60 65 45 135
M8 135 75 90 70 135
M10 155 90 135 85 140
Permissible loads - applications in concrete C20/25 TOP TS - TOP DC TOP BD-TOP BD A2-TOP BD A4 TOP OS-TOP OS A2-TOP OP TOP GS-TOP GS A2 TOP A2 - - -
daN daN daN daN daN
M12 190 120 165 115 160 1 daN â&#x2030;&#x192;1 kg
370 250 140 35 200
490 400 240 75 350
600 500 360 105 470
720 650 600 160 630
Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.
138
Natural stone
Solid brick
pre-setting heavy duty anchors
Vorpa TOP SA e SA A4
internal threaded short body steel anchor for hollow ceiling slaps
Concrete
Products group Suitable for • concrete • pre-stressed concrete hollow-ceiling slabs
TOP SA no accessories
TOP SA BU with 8.8 hexagonal screw
Pre-stressed concrete hollowceiling slabs
Application • Light metal structural work • Brackets and rails for industrial systems such as lighting, heating, ventilation • Suspended ceilings • Pipelines • Timber constructions • Sprinkler systems
product information Benefit • The optimized geometry reduces the energy required for fixing and allows its use even in narrowed spaces. • Suitable for all types of screws, threaded rods and eyebolts with metric thread.
Characteristics • Special short body steel anchor with ant-rotation design and expansion conical nut. • Suitable for hollow-ceiling slabs Benefit • The special design of the anchor allows the use both in hollow materials such as pre-stressed concrete hollow-core slabs both in solid materials with reduced thickness up to 5 cm. • The collar prevents slippage of the anchor into the hole and facilitates the installation since it is not necessary to respect the depth of drilling. Installation sequence
Installation • Pre-setting anchor Suggestion for use • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
Examples of applications
Air conditioning ceiling
Cable rails
possible applications
5 cm min.
Pre - stressed hollow-core concrete slabs = C45/55
Solid material with reduced thickness 139
pre-setting heavy duty anchors
Vorpa TOP SA e SA A4
internal threaded short body steel anchor for hollow ceiling slaps
Concrete
dati tecnici Products group
Pre-stressed concrete hollowceiling slabs
TOP SA - TOP SA A no accessories
Code Steel
Code A4 S. Steel
9650 9651 9652 9655 9656 9657
Description
d0 mm
Lt mm
M
h1 mm
Lv mm
Tinst mm
TOP SA 6 TOP SA 8 TOP SA 10 TOP SA A4 6 TOP SA A4 8 TOP SA A4 10
10 12 14 10 12 14
38 43 52 38 43 52
M6 M8 M10 M6 M8 M10
50 60 65 50 60 65
38 43 52 38 43 52
10 10 20 10 10 20
h1 = Min. hole depth Lt = Anchor length d0 = Hole diameter tfix = Fixture thickness tinst = Torque M = Screw Lv = Minimum depth screw + Tfix + washer hef = Effective anchorage depth Ch = Hex. wrench
TOP SA BU - TOP SA BU A with 8.8 hexagonal screw
Code Steel
Code A4 S. Steel
9659 9660 9661 9665 9666 9667
Description
Lt mm
screw dxL1
d0 mm
h1 mm
Tfix max
Ch
Tinst mm
TOP SA 6 BU TOP SA 8 BU TOP SA 10 BU TOP SA A 6 BU TOP SA A 8 BU TOP SA A 10 BU
38 43 52 38 43 52
M6x50 M8x60 M10x70 M6x50 M8x60 M10x70
10 12 14 10 12 14
50 60 65 50 60 65
8 12 17 8 12 17
10 13 17 10 13 17
10 10 20 10 10 20
Installation data Permissible loads-single application of anchor with 8.8 class screw on hollow prestressed concrete slab class ≥B55 (≥C45/55) Anchor
TOP SA BU M6
TOP SA BU M8 TOP SA BU M10
Slab thickness du (mm) 25-29 30-39 ≥40 25-29 30-39 ≥40 30-39 ≥40
Effective anchorage depth hef (mm) 35 35 35 40 40 40 45 45
Torque Tinst (Nm) 10 10 10 10 10 10 20 20
Permissible load Kn 0,6 0,8 1,9 0,6 0,8 1,9 1,1 2,9
Minimum spacing (mm) 75 85 105 75 85 105 85 105
Minimum edge distance (mm) 110 110 110 110 110 110 110 110
Permissible loads-single application of anchor with A4-70 class screw on hollow prestressed concrete slab class ≥B55 (≥C45/55) Anchor
TOP SA A4 M6
TOP SA A4 M8 TOP SA A4 M10
Slab thickness du (mm) 25-29 30-39 ≥40 25-29 30-39 ≥40 30-39 ≥40
Effective anchorage depth hef (mm) 35 35 35 40 40 40 45 45
Torque Tinst (Nm) 10 10 10 10 10 10 20 20
140
Permissible load Kn 0,6 0,8 1,9 0,6 0,8 1,9 1,1 2,9
Minimum spacing (mm) 75 85 105 75 85 105 85 105
Minimum edge distance (mm) 110 110 110 110 110 110 110 110
pre-setting heavy duty anchors
Vorpa AV Steel anchors
Non-cracked concrete
Natural stone
Solid brick
Products group AV no accessories
Suitable for • Non-cracked concrete • Natural stone • Solid brick
AV BU with 8.8 hexagonal screw
AV BD with stud
AV OS with eyebolt
To fix • Stairs • Window elements • Railings and balustrades • Pipes • Steel structures • Gates • Façades • Machineries • Bars Software Vorpa Calcul Anchor
AV GS with hook-bolt
Examples of applications
AV OA with folded hook-bolt
AV INOX A2 (A2 Stainless Steel) AV INOX A4 (A4 Stainless Steel) no accessories AV INOX A2 BU (A2 Stainless Steel) AV INOX A4 BU (A4 Stainless Steel) with hexagonal head screw
AV INOX A2 BD (A2 Stainless Steel) with threaded stud
Product information Characteristics • Expansion anchor made of galvanized steel or stainless steel composed of anti-rotation cold formed body, expansion conical nut and accessory. • When the screw or hexagon nut is tightened, the cone is pulled into the expansion sleeve and expands it against the hole wall. Benefits • Wide range of accessories • Anti-rotation design with two lateral wings • Surface-flush fixing allows the attached item to be removed and refitted several times • Plastic cap protects against contamination with drilling dust and ensures the thread remains free-running
Installation • Pre-setting anchor Suggestion for use • Choose the most suitable accessory in relation to the application to carry out • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
141
pre-setting heavy duty anchors
Vorpa AV Steel anchors
Non-cracked concrete
Natural stone
Installation sequence
Technical data
AV no accessories
Code
550 551 552 553 554
Description
Lt mm
for screws Ã&#x2DC; mm
d0 mm
h1 mm
AV 6 AV 8 AV 10 AV 12 AV 16
47 55 65 75 92
M6 M8 M10 M12 M16
12 14 16 20 24
55 65 75 85 105
AV BU with 8.8 hexagonal screw
Code
260 262 263 264 261
Description
Lt mm
screws d x Lv mm
d0 mm
h1 mm
Tfix max mm
Tinst Nm
Ch
AV 6 BU AV 8 BU AV 10 BU AV 12 BU AV 16 BU
47 55 65 75 92
M6x55 M8x65 M10x80 M12x100 M16x100
12 14 16 20 24
55 65 75 85 105
10 12 15 20 20
10 25 50 85 150
10 13 17 19 24
Tfix max mm
Tinst Nm
Ch
6 15 15 15 15 15 30 50 70
10 13 13 13 13 13 17 19 24
AV BD with stud
Code
250 251 252 255 256 257 253 254 259
Description
Lt mm
for screws d x Lv mm
d0 mm
h1 mm
AV 6 BD 60 AV 8 BD 50 AV 8 BD 75 AV 8 BD 100 AV 8 BD 120 AV 8 BD 130 AV 10 BD 85 AV 12 BD 105 AV 16 BD 135
47 30 55 55 55 55 65 75 92
M6x60 M8x55 M8x75 M8x100 M8x120 M8x132 M10x85 M12x115 M16x135
12 14 14 14 14 14 16 20 24
55 65 65 65 65 65 75 85 105
142
10 5 15 35 55 65 15 25 30
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length
Solid brick
pre-setting heavy duty anchors
Vorpa AV Steel anchors
Non-cracked concrete
Natural stone
Technical data
AV OS with eyebolt
Code
280 281 282 283 284
Description
Lt mm
for screws d x L0 mm
d0 mm
h1 mm
Tinst Nm
Ø
AV 6 OS AV 8 OS AV 10 OS AV 12 OS AV 16 OS
47 55 65 75 92
M6x55 M8x60 M10x73 M12x90 M16x95
12 14 16 20 24
55 65 75 85 105
5 12 25 40 80
10±0,5 11,8±0,5 14,5±0,5 17±0,5 23±0,5
AV GS with hook-bolt
Code
290 291 292 293 294
Description
Lt mm
hook bolt d x Lg mm
d0 mm
h1 mm
Tinst Nm
P
AV 6 GS AV 8 GS AV 10 GS AV 12 GS AV 16 GS
47 55 65 75 92
M6x55 M8x60 M10x73 M12x90 M16x95
12 14 16 20 24
55 65 75 85 105
5 12 25 40 80
8±0,5 10±0,5 12,5±0,5 16±0,5 19±0,5
AV OA with folded hook-bolt
Code
Description
311 AV 6 OA 312 AV 8 OA
Lt mm
hook bolt d x Lg mm
d0 mm
h1 mm
Tinst Nm
P
47 55
M6x55 M8x65
12 14
55 65
5 12
13±0,5 16±0,5
AV INOX A2 no accessories (A2 Stainless Steel) Code
3550 3551 3552 3547
Description
Lt mm
for screws d x Lv mm
d0 mm
h1 mm
AV INOX A2 6 AV INOX A2 8 AV INOX A2 10 AV INOX A2 12
47 55 65 75
M6 M8 M10 M12
12 14 16 20
55 65 75 85
AV INOX A4 no accessories (A4 Stainless Steel)
4550 AV INOX A4 6 4551 AV INOX A4 8 4552 AV INOX A4 10
47 55 65
M6 M8 M10
12 14 16
143
55 65 75
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length
Solid brick
pre-setting heavy duty anchors
Vorpa AV Steel anchors
Non-cracked concrete
Natural stone
Technical data AV INOX A2 BU with hexagonal head screw (A2 Stainless Steel) Code
3260 3262 3263 3264
Description
AV INOX A2 AV INOX A2 AV INOX A2 AV INOX A2
6 BU 8 BU 10 BU 12 BU
Lt mm
screws d x Lv mm
d0 mm
h1 mm
Tfix max mm
Tinst Nm
Ch
47 55 65 75
M6x55 M8x65 M10x80 M12x100
12 14 16 20
55 65 75 85
10 15 15 20
10 25 50 85
10 13 17 19
AV INOX A4 BU with hexagonal head screw (A4 Stainless Steel)
4260 AV INOX A4 6 BU 4262 AV INOX A4 8 BU 4263 AV INOX A4 10 BU
47 55 65
M6x55 M8x65 M10x80
12 14 16
55 65 75
10 15 15
10 25 50
10 13 17
AV INOX A2 BD with threaded stud (A2 Stainless Steel) Code
Description
3250 AV INOX A2 6 BD 3252 AV INOX A2 8 BD 3253 AV INOX A2 10 BD
Lt mm
stud d x Lb mm
d0 mm
h1 mm
Tfix max mm
Tinst Nm
Ch
47 55 65
M6x60 M8x75 M10x85
12 14 16
55 65 75
10 15 15
10 25 40
10 13 17
Installation data
AV Anchor Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness
Scr Ccr Smin Cmin hmin
mm mm mm mm mm
M6 160 90 70 60 100
M8 180 100 80 70 100
M10 220 120 90 80 100
M12 280 150 120 100 120
Permissible loads - applications in concrete C20/25 AV BU - AV BU A2/A4 AV - AV A2/A4 - AV BD AV OS AV GS AV OA A2/A4 Stainless Steel screws - - -
daN daN daN daN daN daN
M16 320 170 130 115 140
M20 440 185 145 125 160
1 daN â&#x2030;&#x192;1 kg 230 220 140 35 35 230
420 350 240 75 75 420
590 470 360 100 100 590
750 700 600 110 110
1080 800 700 200
1250 950
Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.
144
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length
Solid brick
pre-setting heavy duty anchors
Vorpa AVZ
Steel expansion shield anchors
Non-cracked concrete
Natural stone
Solid brick
Perforated bricks
Products group AVZ no accessories
Suitable for • Non-cracked concrete • Natural stone • Solid brick • Perforated brick
AVZ BU with 8.8 hexagonal screw
To fix • Heavy structural works • Machineries • Stairs • Balustrades • Gates • Façades • Railings
Software Vorpa Calcul Anchor
Examples of applications
Product information Characteristics • Steel anchor composed of 4 segments anti-rotation cold formed body, expansion conical nut and accessory. Benefits • Anti-rotation during the installation procedure • Smooth expansion thanks to the four segments body • Suitable for applications on poor-quality concrete and non- homogeneous materials • High expansion and grip
Installation • Pre-setting anchor Suggestion for use • Choose the most suitable accessory in relation to the application to carry out • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
Installation sequence
145
pre-setting heavy duty anchors
Vorpa AVZ
Steel expansion shield anchors
Non-cracked concrete
Natural stone
Solid brick
Technical data
AVZ no accessories
Code
831 832 833 834 835
Description
Lt mm
for screws Ă&#x2DC; mm
d0 mm
h1 mm
AVZ 6 AVZ 8 AVZ 10 AVZ 12 AVZ 16
40 50 60 80 100
M6 M8 M10 M12 M16
10 14 16 20 25
50 60 70 90 110
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
AVZ BU with 8.8 hexagonal head screw
Code
841 842 843 844 845
Description
Lt mm
screws d x Lv mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Ch
AVZ AVZ AVZ AVZ AVZ
40 50 60 80 100
M6x55 M8x70 M10x80 M12x100 M16x130
10 14 16 20 25
50 60 70 90 110
15 20 20 20 25
10 25 50 85 150
10 13 17 19 24
6 BU 8 BU 10 BU 12 BU 16 BU
Installation data
AVZ Anchor Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness
Scr Ccr Smin Cmin hmin
mm mm mm mm mm
M6 200 100 80 50 100
M8 220 100 80 50 100
M10 260 130 100 65 150
Permissible loads - applications in concrete C20/25 AVZ BU - - -
daN
M12 320 160 130 80 160
M16 440 220 170 110 220
1 daN â&#x2030;&#x192;1 kg 330
450
530
750
1200
Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.
146
Perforated bricks
pre-setting heavy duty anchors
Vorpa VHM
Zamak expansion shield anchors
Non-cracked concrete
Natural stone
Solid brick
Perforated bricks
Products group VHM no accessories
VHM BU with 8.8 hexagonal screw
Suitable for • Non-cracked concrete • Natural stone • Solid brick • Perforated brick
To fix • Heavy structural works • Machineries • Railings • Profiles • Façades
Software Vorpa Calcul Anchor
Examples of applications
Product information Characteristics • Zamak anchor composed of 4 shells cold formed body, with anti-rotation design, expansion conical nut and accessory. Benefits • Anti-rotation during the installation • No corrosion body, suitable for wet area, old and non-homogeneous materials • Smooth expansion thanks to the four shells body • The body is made of zamak (96% zinc. 4% alluminium)
Installation • Pre-setting anchor Suggestion for use • Choose the most suitable accessory in relation to the application to carry out • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
Installation sequence
147
pre-setting heavy duty anchors
Vorpa VHM
Zamak expansion shield anchors
Non-cracked concrete
Natural stone
Solid brick
Technical data
VHM no accessories
Code
811 812 813 814 815
Description
Lt mm
for screws mm
d0 mm
h1 mm
VHM 6 VHM 8 VHM 10 VHM 12 VHM 16
47 50 57 72 107
M6 M8 M10 M12 M16
12 14 16 20 25
55 60 70 80 115
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
VHM BU with 8.8 hexagonal screw
Code
821 822 823 824 825
Description
Lt mm
screws d x Lv mm
d0 mm
h1 mm
Tfix max mm
Tinst Nm
Ch
VHM 6 BU VHM 8 BU VHM 10 BU VHM 12 BU VHM 16 BU
47 50 57 72 107
M6x55 M8x70 M10x80 M12x100 M16x150
12 14 16 20 25
55 60 70 80 115
10 15 20 20 20
10 25 50 80 150
10 13 17 19 24
Installation data
VHM Anchor Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness
Scr Ccr Smin Cmin hmin
mm mm mm mm mm
M6 200 100 85 50 100
M8 220 100 85 50 100
M10 260 130 105 65 150
M12 320 160 135 80 160
Permissible loads - applications in concrete C20/25 VHM BU - - -
daN
M16 440 225 180 110 200 1 daN â&#x2030;&#x192;1 kg
300
400
500
600
1200
Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.
148
Perforated bricks
pre-setting heavy duty anchors
Vorpa AVZ.G
Sherardise steel shield anchors
Non-cracked concrete
Natural stone
Solid brick
Perforated bricks
Products group AVZ.G no accessories
AVZ.G BU with 8.8 hexagonal head screw
Suitable for • Non-cracked concrete • Natural stone • Solid brick • Perforated brick
To fix • Heavy structural works • Machineries • Railings • Balustrades • Gates • Profiles • Stairs • Façades Software Vorpa Calcul Anchor
Examples of applications
Product information Characteristics • Steel anchor made of sherardise steel composed of 4 segments anti-rotation cold formed body, expansion conical nut and steel spring plus accessory. Benefits • Anti-rotation during the installation procedure • Smooth expansion thanks to the four segments body • Indicated also for oversize holes • Suitable for porous and non-homogeneous materials; it can be used even in case of defective base materials.
Installation • Pre-setting anchor Suggestion for use • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
Installation sequence
149
pre-setting heavy duty anchors
Vorpa AVZ.G
Sherardise steel shield anchors
Non-cracked concrete
Natural stone
Solid brick
Technical data
AVZ.G no accessories
Code
1831 1832 1833 1834 1835
Description
Lt mm
for screws Ă&#x2DC; mm
d0 mm
h1 mm
AVZ.G 6 AVZ.G 8 AVZ.G 10 AVZ.G 12 AVZ.G 16
40 50 60 80 100
M6 M8 M10 M12 M16
12 14 16 20 28
45 55 65 85 105
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
AVZ.G BU with 8.8 hexagonal head screw
Code
1841 1842 1843 1844 1845
Description
Lt mm
screws d x Lv mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Ch
AVZ.G 6 BU AVZ.G 8 BU AVZ.G 10 BU AVZ.G 12 BU AVZ.G 16 BU
40 50 60 80 100
M6x55 M8x70 M10x80 M12x100 M16x130
12 14 16 20 28
45 55 65 85 105
15 20 20 20 25
10 25 50 85 150
10 13 17 19 24
Installation data
AVZ.G Anchor Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness
Scr Ccr Smin Cmin hmin
mm mm mm mm mm
M6 200 100 80 50 100
M8 220 100 80 50 100
M10 260 130 100 65 150
Permissible loads - applications in concrete C20/25 AVZ.G - - -
daN
M12 320 160 130 80 160
M16 440 220 170 110 220
1 daN â&#x2030;&#x192;1 kg 370
580
760
1140
2000
Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.
150
Perforated bricks
through-setting heawy duty anchors
Vorpa VHS
Steel anchors with European Technical Assessment
Non-cracked concrete
Natural stone
Solid brick
Products group VHS C [*] with 8.8 hexagonal head screw
Approved for • Non-cracked concrete C20/25 - C50/60 - M6-M12 • Non-cracked concrete C12/15
VHS B with threaded stud
Also suitable for • Natural stone • Solid brick
VHS F with 10.9 countersunk head
To fix • Plates • Plants engineering • Stairs • Window and door frames • Profiles • Gates • Railings
[*]
European Technical Assessment Option 8 for non-cracked concrete
VHS OS with eyebolt
Software Vorpa Calcul Anchor
VHS D INOX A2 (A2 Stainless Steel) with hexagonal head screw
For version with ETA: As it can also be used on concrete with different strength characteristics, as specified in ETA, on compact natural stone and others materials (exception not included in ETA), specific on-site tests by the user are necessary VHS FI INOX A2 (A2 Stainless Steel) with countersunk head
VHS PF with 8.8 hexagonal head screw Examples of applications
151
through-setting heawy duty anchors
Vorpa VHS
Steel anchors with European Technical Assessment
Non-cracked concrete
Natural stone
Solid brick
Product information Installation • Through-setting anchor
Characteristics • Through steel anchor with slots on the body and on the expansion conical nut
Suggestion for use • Choose the most suitable accessory in relation to the application to carry out • Choose the right size of the anchor according the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
Benefits • European Technical Assessment option 8 • Smooth expansion thanks to the slots on the body and on the expansion conical nut • High setting quickness through the object to be fixed • High performances Installation sequence
Technical data
VHS C with 8.8 hexagonal head screw
Code
Description
Lt mm
for screws d x Lv mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Ch
* 1725 1726 1724 * 1727 1728 3473 4473 * 1729 1730 3475 4475 * 1732 5560 5561 5562
VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C
45 65 100 50 70 100 120 60 80 100 120 130 90 110 130
M6x50 M6x70 M6x100 M8x55 M8x75 M8x100 M8x120 M10x65 M10x80 M10x100 M10x120 M10x130 M12x90 M12x110 M12x130
8 8 8 10 10 10 10 12 12 12 12 12 16 16 16
50 50 50 55 55 55 55 60 60 60 60 60 85 85 85
4 24 54 5 25 45 65 5 25 45 65 75 10 30 50
10 10 10 25 25 25 25 40 40 40 40 40 65 65 65
10 10 10 13 13 13 13 17 17 17 17 17 19 19 19
8/4-45 8/24-65 8/54-100 10/5-50 10/25-70 10/45-100 10/65-120 12/5-60 12/25-80 12/45-100 12/65-120 12/75-130 16/10-90 16/30-110 16/50-130
* Non included in ETA
152
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length
through-setting heawy duty anchors
Vorpa VHS
Steel anchors with European Technical Assessment
Non-cracked concrete
Natural stone
Technical data
VHS D INOX A2 (A2 Stainless Steel) with hexagonal head screw Code
2525 2526 2500 2527 2528 2473 5473 2529 2530 2475 5475 5476 5477 5479
Description
Lt mm
for screws d x Lv mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Ch
VHS D A2 8/4-45 VHS D A2 8/24-65 VHS D A2 8/54-100 VHS D A2 10/5-50 VHS D A2 10/25-70 VHS D A2 10/45-100 VHS D A2 10/65-120 VHS D A2 12/5-60 VHS D A2 12/25-80 VHS D A2 12/45-100 VHS D A2 12/65-120 VHS D A2 16/10-90 VHS D A2 16/30-110 VHS D A2 16/50-130
45 65 100 50 70 100 120 60 80 100 120 90 110 130
M6x50 M6x70 M6x100 M8x55 M8x75 M8x100 M8x120 M10x65 M10x80 M10x100 M10x120 M12x90 M12x110 M12x130
8 8 8 10 10 10 10 12 12 12 12 16 16 16
50 50 50 55 55 55 55 60 60 60 60 85 85 85
4 24 54 5 25 45 65 5 25 45 65 10 30 50
10 10 10 25 25 25 25 40 40 40 40 65 65 65
10 10 10 13 13 13 13 17 17 17 17 19 19 19
VHS B with threaded stud
Code
Description
Lt mm
stud d x Lb mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Ch
535 536 2534 537 538 2538 539 540 2540 2541 55561 55562 52536
VHS B VHS B VHS B VHS B VHS B VHS B VHS B VHS B VHS B VHS B VHS B VHS B VHS B
45 65 100 50 70 100 60 80 100 120 110 130 140
M6x57 M6x73 M6x110 M8x60 M8x80 M8x102 M10x75 M10x95 M10x110 M10x130 M12x110 M12x130 M12x140
8 8 8 10 10 10 12 12 12 12 16 16 16
50 50 50 55 55 55 60 60 60 60 85 85 85
4 24 54 5 25 45 5 25 45 65 30 50 60
6 6 6 15 15 15 30 30 30 30 65 65 65
10 10 10 13 13 13 17 17 17 17 19 19 19
8/4-45 8/24-65 8/54-100 10/5-50 10/25-70 10/45-100 12/5-60 12/25-80 12/45-100 12/65-120 16/30-110 16/50-130 16/60-140
VHS F with 10.9 countersunk head
Code
4525 4526 4537 4527 4528 4534 4529 4530 4535 5565 5566
Description
Lt mm
screws d x Lv mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Ch
VHS F 8/4-45 VHS F 8/24-65 VHS F 8/54-100 VHS F 10/5-50 VHS F 10/25-70 VHS F 10/45-100 VHS F 12/5-60 VHS F 12/25-80 VHS F 12/45-100 VHS F 16/10-90 VHS F 16/30-110
45 65 100 50 70 100 60 80 100 90 110
M6x50 M6x70 M6x100 M8x60 M8x80 M8x100 M10x65 M10x80 M10x100 M12x90 M12x110
8 8 8 10 10 10 12 12 12 16 16
50 50 50 55 55 55 60 60 60 85 85
4 24 54 5 25 45 5 25 45 10 30
10 10 10 25 25 25 40 40 40 65 65
4 4 4 5 5 5 6 6 6 8 8
153
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length
Solid brick
through-setting heawy duty anchors
Vorpa VHS
Steel anchors with European Technical Assessment
Non-cracked concrete
Natural stone
Technical data
VHS FI INOX A2 with A2 Stainless Steel countersunk Code
5530 5531 5537 5532 5533 5529 5534 5535 5536
Description
Lt mm
screws d x Lv mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Ch
VHS FI A2 8/4-45 VHS FI A2 8/24-65 VHS FI A 8/54-100 VHS FI A2 10/5-50 VHS FI A2 10/25-70 VHS FI A2 10/45-100 VHS FI A2 12/5-60 VHS FI A2 12/25-80 VHS FI A2 12/45-100
45 65 100 50 70 100 60 80 100
M6x50 M6x70 M6x100 M8x60 M8x80 M8x100 M10x65 M10x80 M10x100
8 8 8 10 10 10 12 12 12
50 50 50 55 55 55 60 60 60
4 24 54 5 25 45 5 25 45
10 10 10 25 25 25 40 40 40
4 4 4 5 5 5 6 6 6
VHS OS with eyebolt
Code
Description
575 VHS OS 8/45 576 VHS OS 10/50 577 VHS OS 12/60
Lt mm
45 50 60
eyebolt d x LO mm
d0 mm
h1 mm
Tinst Nm
Ch
M6x55 M8x60 M10x73
8 10 12
55 60 85
6 15 30
10±0,5 11,8±0,5 14,5±0,5
154
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length
Solid brick
through-setting heawy duty anchors
Vorpa VHS
Steel anchors with European Technical Assessment
Non-cracked concrete
Installation data
VHS Anchor Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness
Scr Ccr Smin Cmin hmin
M6 180 100 95 50 80
mm mm mm mm mm
M8 240 120 120 60 100
M10 250 150 145 75 120
Permissible loads - applications in concrete C20/25 Screws cl. 10.9 Screws A2 Threaded stud cl. 5.8 VHS OS
M12 280 170 175 90 150 1 daN â&#x2030;&#x192;1 kg
daN daN daN daN
180 140 105 35
250 220 160 75
Permissible loads - applications in solid brick compression resistance 18/20 N/mm2
400 380 280 100
930 700 540
1 daN â&#x2030;&#x192;1 kg
Screws cl. 8,8 daN 100* 160* 280* 390* * Indicative values - For applications on solid bricks is not possible to show specific loading values because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department. - - -
Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.
Installation data M6
M8
M10
M12
mm mm mm mm mm Nm
8 31 8 50 9 10
10 35 10 55 11 25
12 40 12 60 13 40
16 60 16 85 17 65
Scr,N Ccr,N Smin Cmin hmin
mm mm mm mm mm
93 46,5 95 50 80
105 52,5 120 60 100
120 60 145 75 120
180 90 175 90 150
Nrk,P C20/25
KN
6 1 1 1
7,5 1 1 1
12 1 1 1
20 1 1 1
VRk,S C20/25 MRK,S
KN Nm
7,5 12,2
12 30
20 59,8
30 104,8
Nrk,P VRk,S MRK,S
KN KN Nm
4 6 9,7
5 9,6 24
8 16 47,8
13 24 83,8
N T M
KN KN Nm
2,5 4,2 6,5
3,5 6,8 17
5,7 11,4 34
9,2 17 59,5
Anchor type Installation data VHS C Anchor diameter Effective anchorage depth Drill hole diameter Drill hole depth Hole diameter in the fixture Torque moment
d hef d0 h1 df Tinst
Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum thickness member Characteristic values VHS C Pull out failure c C30/37 c C40/50 c C50/60 Shear failure Bending moment Values where the reduction factor Pull out failure Shear failure Bending moment Recommended loads VHS C Pull out failure Shear failure Bending moment
155
Natural stone
Solid brick
through-setting heawy duty anchors
Vorpa VHS
Steel anchors with European Technical Assessment
Non-cracked concrete
Natural stone
Technical data
VHS PF with 8.8 hexagonal head screw
Code
555 1558 564 1567 580 1586 587 1592 1593
Description
VHS PF VHS PF VHS PF VHS PF VHS PF VHS PF VHS PF VHS PF VHS PF
14/10-70 14/20-80 14/40-100 14/60-120 16/15-80 16/35-100 16/55-120 16/75-140 16/95-160
Lt mm
screws d x Lv mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Ch
70 80 100 120 80 100 120 140 160
M10x70 M10x80 M10x100 M10x120 M12x80 M12x100 M12x120 M12x140 M12x160
14 14 14 14 16 16 16 16 16
65 65 65 65 70 70 70 70 70
10 20 40 60 15 35 55 75 95
40 40 40 40 75 75 75 75 75
17 17 17 17 19 19 19 19 19
A2 stainless steel version available
Installation data
VHS PF Anchor Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness
Scr Ccr Smin Cmin hmin
M10 250 150 145 75 120
mm mm mm mm mm
Permissible loads - applications in concrete C20/25 VHS PF - - -
M12 280 170 175 90 150 1 daN â&#x2030;&#x192;1 kg
daN
600
850
Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.
Esempi di applicazione
156
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length
Solid brick
through-setting heawy duty anchors
Vorpa VTS steel anchors
Non-cracked concrete
Natural stone
Solid brick
Products group Suitable for • non-cracked concrete • natural stone • solid brick
VTS
with 8.8 hexagonal head screw
suitable to fix • stairs • window and door frames • profiles • gates
Product information Installation • Through-setting anchor
Characteristics • Through steel anchor with slots on the body and on the expansion conical nut
Consigli per l’utilizzo • Choose the most suitable accessory in relation to the application to carry out • Choose the right size of the anchor according the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
Benefits • Smooth expansion thanks to the slots on the body and on the expansion conical nut • High setting quickness through the object to be fixed
Installation sequence
Technical data Code
8883 8884 8885 8886 8887 8888 8889 8890 8891 8892 8893
Description
Lt mm
d0 mm
h1 mm
tfixmax mm
Tinst mm
Ch
VTS VTS VTS VTS VTS VTS VTS VTS VTS VTS VTS
45 70 90 55 80 100 65 80 100 75 110
8 8 8 10 10 10 12 12 12 16 16
45 45 45 50 50 50 60 65 65 65 70
5 30 50 10 35 55 10 20 40 15 45
10 10 10 25 25 25 50 50 50 75 75
10 10 10 13 13 13 13 17 17 17 17
8/5-45 8/30-70 8/50-90 10/10-55 10/35-80 10/55-100 12/10-65 12/20-80 12/40-100 16/15-75 16/45-110
Installation data Anchor type Critical axial spacing Critical edge distance Minimum structural thichness
Scr Ccr hmin
mm mm mm
M6 120 60 100
M8 135 67,5 100
M10 165/180 85/90 100
daN
90
140
230/250
Permissable loads - Applications in concrete C20/25 Screws cl. 8.8 - - -
M12 180/195 90/97,5 130 1 daN ≃1 kg 255/280
Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads
157
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
pre-setting heavy duty anchors
Vorpa VO Brass anchors
Wood
Concrete
Natural stone
Products group VO no accessories
Suitable for • Wood • Concrete • Natural stone • Solid brick
To fix • Railings • Profiles • Stairs • Wood columns
VO S with double threaded screw for wood column
Examples of applications
Product information Characteristics • Brass anchor for metric screws • The version VO S is composed of a brass anchor and a double threaded screw for wood column Benefits • Smooth expansion thanks to the slots on the body • Special surface structure prevents it rotating in the hole • Expansion carried out by screwing the accessory
Installation • Pre-setting anchor Suggestion for use • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
Installation sequence
VO anchor
VO S anchor 158
Solid brick
pre-setting heavy duty anchors
Vorpa VO Brass anchors
Wood
Concrete
Natural stone
Technical data
VO no accessories
Code
Description
50580 581 582 583 584 585 50587
VO 4 VO 5 VO 6 VO 8 VO 10 VO 12 VO 16
Lt mm
for screws Ø mm
d0 mm
h1 mm
M4 M5 M6 M8 M10 M12 M16
5 6,5 8 10 12 15 20
20 30 30 35 40 45 50
16 22 24 30 35 40 45
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
VO S with double threaded screw for wood column Code
Description
408 VO S 8/90 409 VO S 10/120
Lt mm
30 35
screws Ø mm
d0 mm
h1 mm
M8x90 M10x120
10 12
35 40
Installation data
VO Anchor Permissible loads - applications in concrete C20/25 VO daN - - -
M5
M6
M8
M10
50
140
200
250
M12 M16 1 daN ≃1 kg 340 450
Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.
159
Solid brick
through-setting heawy duty anchors
Vorpa safety threaded nuts Safety zincplated and A2 stainless steel threaded nuts product group Per fix • Windows frame • Railings • Garden furniture • Road sign • gazebo
Characteristics: shear threaded nut • Anti-burglar nut with one-sided clamping system • With a torque of about 19 Nm, the hexagonal head detaches without giving the possibility of tampering and dissambly of the object Characteristics: threaded nut AF DRIVE • The special design of the permanent AF nut once brought to tightening, guarantees the inviolability of the mechanical anchor technical data DTS P INOX A Safety A2 stainless steel threaded nut with shear head and through hole Code
58999 59000 59001 59006
Description
DTS P DTS P DTS P DTS P
M M M M
Internal threaded
6/13 8/17 10/19 12/19
DTS PZ Safety zincplated threaded nut with shear head and through hole
Hexagon size
Tinst
Code
Description
Internal threaded
Nm indicative
Tinst
Hexagon size
Nm indicative
M 6 M 8 M 10 M 12
13 17 19 19
15-25 30-40 75-85
59000Z 59001Z 59002Z
DTS PZ M 8/17 DTS PZ M 10/19 DTS PZ M 12/22
M 8 M 10 M 12
17 19 22
15-25 30-40 75-85
M 8 M 10
13 17
15-25 30-40
58996Z 58976Z
DTS PZ M 8/13 DTS PZ M 10/17
M 8 M 10
13 17
15-25 30-40
Reduced hexagonal size version:
58996 58997
DTS P M 8/13 DTS P M 10/17
90840
90841
Ø 90842
Ø 90843
Code
90840 90841 90842 90843 4042 4049
DTS INOX A Safety A2 stainless steel M8 threaded nut with shear head
Description
Internal threaded
DTS COUNTERSUNK DTS DTS 8/12 DTS 8/10 A2 S.S. WASHER 10x20x2 A2 S.S. WASHER 12x22x2,5
M 8 M 8 M 8 M 8
Hexagon size
15 13 15 15
Ø
90840Z
90841Z
Ø 90842Z
Ø 90843Z
Tinst
Code
19 19 19 19
90840Z 90841Z 90842Z 90843Z
Description
Nm indicative
12 10
DTS Z COUNTERSUNK DTS Z DTS Z 8/12 DTS Z 8/10
TORQUE TOOL FOR ANCHOR AND NUT AF
Code
Description
72589 72592 72590 72591
AF AF NUT AF NUT AF
M 8 M 10 M 8 M 10
DTS Z Safety zincplated M8 threaded nut with shear head
Nut
Mechanical anchor VHS AF
art. 72590 art. 72591
code 5717/5710/5712
A mm
B mm
16,10 20,10
7,30 9,10
160
Internal threaded
M 8 M 10
Internal threaded
M 8 M 8 M 8 M 8
Hexagon size
15 13 15 15
Ø
Tinst
Nm indicative
12 10
19 19 19 19
through-setting heawy duty anchors
Vorpa Security Anchor VHS
Special permanent temper-proof fixings as protection against burglary and thievery
Non-cracked concrete
Natural stone
Solid brick
Products group VHS AE with A2 stainless steel shear nut
Suitable for • Non-cracked concrete • Natural stone • Solid brick
VHS Z with A2 stainless steel shear nut
VHS AF with steel shear nut AF
VHS CX with Torx bit 8.8 screw VHS CX INOX A2 with A2 stainless steel Torx bit screw
Examples of applications
161
To fix • Window and door frames • Gates • Railings • Iron bars • Traffic signals • Garden fittings
through-setting heawy duty anchors
Vorpa Security Anchor VHS
Special permanent temper-proof fixings as protection against burglary and thievery
Non-cracked concrete
Natural stone
Product information Installation • Through-setting anchor
Characteristics • Through steel anchor with slots on the body and on the expansion conical nut completed of shear nut.
Suggestion for use • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
Benefits • Smooth expansion thanks to the slots on the body and on the expansion conical nut • High setting quickness through the object to be fixed • High performances • Shear nut
Installation sequence
Technical data VHS AF sleeve anchor is a through fixing, thus ensuring fast and simple installation. Ideal for many security applications in a wide variety of base materials. The unique AF drive permanent nut offers an accurate torque controlled security fixing which can be re-torqued if necessary. Reduced hole diameter compared to TOP version.
VHS AF with AF steel shear nut
Code
Description
7517 VHS AF 10/5-50 7510 VHS AF 10/25-70 7512 VHS AF 10/55-100
Lt mm
screws d x Lb mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Ch
50 70 100
M8x55 M8x75 M8x100
10 10 10
50 50 50
5 25 55
15 15 15
AF M8 AF M8 AF M8
AF DRIVER SOCKET AND AF PERMANENT NUT
Code
Description
72589 72592 72590 72591
AF M8 AF M10 DADO AF M8 DADO AF M10
internal thread
for nut
for anchor TOP AF
art. 72590 art. 72591
art. 7578/7562/7563 -
M8 M10
162
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
Solid brick
through-setting heawy duty anchors
Vorpa Security Anchor VHS
Special permanent temper-proof fixings as protection against burglary and thievery
Non-cracked concrete
Natural stone
Technical data Security anchors with shear nut for final fixing of windows, iron fences, gates, etc. Suitable for every compact building materials. Exceeding a torque of 19 Nm the hexagonal head takes off giving no chance to slip off the fixing. Hexagonal head and washer are made in A2 Stainless Steel. Reduced hole diameter compared to TOP version.
VHS AE with A2 stainless steel shear nut
Code
Description
517 VHS AE 10/8-60 510 VHS AE 10/28-75 512 VHS AE 10/48-100
Lt mm
screws d x Lb mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Ch
60 75 100
M8x60 M8x75 M8x100
10 10 10
55 55 55
8 28 48
* * *
15 15 15
* Approximate breaking torque at 19Nm
VHS Z with countersunk head and A2 stainless steel shear nut
Code
Description
2588 VHS Z 10/18-65 2510 VHS Z 10/38-85
Lt mm
screws d x Lb mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Ch
65 85
M8x60 M8x80
10 10
55 55
18 38
* *
15 15
* Approximate breaking torque at 19Nm
Installation sequence
Examples of applications
163
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
Solid brick
through-setting heawy duty anchors
Vorpa Security Anchor VHS
Special permanent temper-proof fixings as protection against burglary and thievery
Non-cracked concrete
Natural stone
Technical data Security anchors for final fixing of windows, iron fences, gates, etc. granting protection against burglary and thievery. Head screw is characterized by Torx bit T40. Zamak star must be hammered into Torx bit making the anchor impossible to remove. Reduced hole diameter compared to TOP version.
VHS CX with Torx bit 8.8 screw
Description
Lt mm
screw d x Lb mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Torx bit
50517 VHS CX 10/15-60 50510 VHS CX 10/35-80 50511 VHS CX 10/55-100
60 80 100
M8x60 M8x80 M8x100
10 10 10
50 50 50
15 35 55
25 25 25
T40 T40 T40
15 35 55
25 25 25
T40 T40 T40
Code
VHS CX with Torx bit 8.8 screw
60517 VHS CX A2 10/15-60 60 60510 VHS CX A2 1 0/35-80 80 60511 VHS CX A2 1 0/55-100 100
M8x60 M8x80 M8x100
10 10 10
50 50 50
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
Installation sequence
Installation data
VHS Anchor Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness
Scr Ccr Smin Cmin hmin
M8 240 120 120 60 100
mm mm mm mm mm
Permissible loads - applications in concrete C20/25 VHS AF - VHS Z - VHS AE 10 - M8 VHS CX cl. 8.8 10 - M8 VHS CX INOX A2 10 - M8 - - -
1 daN â&#x2030;&#x192;1 kg 200 230 230
daN daN daN
Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.
164
Solid brick
through-setting heawy duty anchors
Vorpa Security Anchor TOP
Special permanent temper-proof fixings as protection against burglary and thievery
Non-cracked concrete
Natural stone
Solid brick
Products group TOP AF with zincplated steel shear nut AF
Suitable for • Non-cracked concrete • Natural stone • Solid brick
TOP AE with A2 stainless steel shear nut
To fix • Window and door frames • Gates • Railings • Iron bars • Traffic signals • Garden fittings
Examples of applications
Product information Characteristics • Through steel anchor composed of anti-rotation cold formed body and expansion conical nut with shear nut. Benefits • Anti-rotation during the installation procedure • Possibility of pre-setting applications and through-setting applications • Smooth expansion thanks to the three sectors body • Shear nut
Installation • Through-setting anchor Suggestion for use • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
Installation sequence
TOP AF
TOP AE
165
through-setting heawy duty anchors
Vorpa Security Anchor TOP
Special permanent temper-proof fixings as protection against burglary and thievery
Non-cracked concrete
Natural stone
Solid brick
Technical data TOP AF sleeve anchor is a through fixing, thus ensuring fast and simple installation. Ideal for many security applications in a wide variety of base materials. The unique AF drive permanent nut offers an accurate torque controlled security fixing which can be re-torqued if necessary.
TOP AF with zincplated steel shear nut
Code
Description
7578 TOP AF 12/6-55 7562 TOP AF 12/25-75 7563 TOP AF 12/45-95
Lt mm
screws d x Lb mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Driver Socket Ch
55 75 95
M8x55 M8x75 M8x95
12 12 12
55 55 55
6 25 45
15 15 15
AF M8 AF M8 AF M8
AF DRIVER SOCKET AND AF PERMANENT NUT
Code
Description
72589 72592 72590 72591
AF M8 AF M10 DADO AF M8 DADO AF M10
internal thread
for nut
for anchor TOP AF
art. 72590 art. 72591
art. 7578/7562/7563 -
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
M8 M10
Security anchors with shear nut for final fixing of windows, iron fences, gates, etc. Suitable for every compact building materials. Exceeding a torque of 19 Nm the hexagonal head takes off giving no chance to slip off the fixing. Hexagonal head and washer are made in A2 Stainless Steel.
TOP AE with A2 stainless steel shear nut
Code
Description
578 TOP AE 12/6-55 562 TOP AE 12/25-75 563 TOP AE 12/45-100
Lt mm
screws d x Lb mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Ch
55 75 100
M8x55 M8x75 M8x100
12 12 12
55 55 55
6 25 45
* * *
15 15 15
* Approximate breaking torque at 19Nm Installation data
Top Anchor Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness
Scr Ccr Smin Cmin hmin
M8 135 75 90 70 135
mm mm mm mm mm
Permissible loads - applications in concrete C20/25 TOP AE 12 - M8 TOP AF 12 - M8
1 daN â&#x2030;&#x192;1 kg 400 400
daN daN
166
- Always respect the installation parameters - In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) - The table shows the permissible loads for tension, shear and combined tension and shear loads.
pre-setting heavy duty anchors
Vorpa Security Anchor VH AE Nylon plugs
Solid brick
Perforated bricks
Products group VH AE with steel screw and A2 stainless steel shear nut
To fix • Window and door frames • Gates • Railings • Iron bars • Traffic signals • Garden fittings
Suitable for • Solid brick • Perforated brick
Product information Characteristics • Nylon plug with diagonal slots
Installation • Through-setting anchor
Benefits • Anti-rotation system during the installation • Possibility of pre-setting applications and through-setting applications • Smooth expansion thanks to the slots on the body • Shear nut
Suggestion for use • Choose the most suitable accessory in relation to the application to carry out • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
Installation sequence
Technical data Security anchors with shear nut for final fixing of windows, iron fences, gates, etc. Suitable for every compact building materials. Exceending a torque of 19 Nm the exagonal head takes off giving no change to slip off the fixing. Hexagonal head and washer are made in A2 Stainless Steel.
Code
Description
588 VH AE 558 VH AE
8/5-75 8/25-95
Lt mm
screw d x Lb mm
d0 mm
h1 mm
tfix max mm
Tinst Nm
Ch
70 70
M8x75 M8x95
12 12
75 75
5 25
* *
13 13
* Approximate breaking torque at 19Nm Installation data Permissible loads - applications in concrete C20/25 SAFETY ANCHOR VH - - -
1 daN ≃1 kg
daN
150
Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.
167
Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner
through-setting heawy duty anchors
Vorpa Wire rope clip Accessories
Product group Suitable for • Wire ropes • Cables • Tie rods • Ropes
Suitable to fix • Radio systems cables • TV systems cables • Tie rods for orchards • Wire clotheslines • Tensioning cables
Characteristics • Forged wire rope clip Examples of installation
Examples of application
Correct method of fitting Wire Rope Grips
Incorrect method of fitting Wire Rope Grips
Technical data Code
1520 1521 1522 1523 1524 * * * * * * * * * * * * *
ØR mm
Ø R”
A mm
B mm
C mm
D mm
E mm
F mm
I mm
L mm
S mm
T mm
2-3 4-5 6 8 10 11 12 14 16 18 20 22 24-25 26-28 30-32 36-38 42-45 48-50
1/8 3/16 1/4 5/16 3/8 7/16 1/2 9/16 5/8 11/16 3/4 7/8 1 1.1/8 1.1/4 1.1/2 1.3/4 2
21 25 30 33 38 40 43 46 53 59 60 64 70 80 92 95 115 116
12 18 19 20 22 22,5 25 27 31 33 34 34 40 43 45 51 58 59
9 9 10 10,5 11 13 13 17 18 20 22 23 24 30 34 39 43 46
M4 M5 M6 M6 M8 M8 M10 M10 M10 M12 M12 M12 M12 M14 M16 M16 M20 M20
5 5 6 6 6 6 6 7,5 8 8 9 9,5 10 12 14 16 16 16
12 14 19 22 22 23 30 30 32 38 38 42 46 50 70 75 83 83
9 11 15 16 19 21 23 25 28 30 33 37 40 42 49 57 70 70
20 25 33 35 43 43 55 55 63 78 78 80 88 97 130 135 158 178
1,25 2,46 4,24 4,24 10,2 10,2 20,11 20,11 20,11 34,43 34,43 34,43 34,43 54,77 85,14 85,14 167,2 167,2
3 3 4 4 4 4 5 5 5 5 5 6 6 7 8 8 10 10
S = Torque (with 0,10 safety factor included) T = Nr. clips to use
* Available on request
168
R
L
E
F I A
C D B
heavy duty anchors
Vorpa Wire rope clip (italian TELECOM-ENEL standard) Galvanized forged clamp for rope, cables and tie rods with serial number product group Suitable for • wire ropes • cables • rods
Wire rope clip
To fix • steel ropes • plant cables • rods • tension ropes and cables • ropes ENEL number 263202 • ropes serial number TELECOM 02076-8
Caution Before starting to operate, perform the correspondence check functional and performance of the clamp installed to confirm its suitability
examples of applications and instructions Installation mode It is advisable to apply the clamps at a distance from one another not less than 22 mm
Tz
Correct installation
incorrect installation
INTERVENTION FREQUENCY QUARTERLY ANNUAL X X X X X
CHECK Visual conditions Tightening torque Deformation Usury Conservation status
Selection criteria • The clips must be chosen according to the cable diameter • The clips must be used only for wire ropes • Permissible temperature between -20°C e + 80°C • Periodically check the functionality and efficiency of the clamp • The tightening torque must be transmitted with a tightening torque wrench • The clamp works efficiently until its geometric and physical characteristics and the applied tightening torque remain unchanged
technical data
Incorrect use In order not to compromise the safety and functionality of the product and not cause serious situations of danger for the safety of people or things • DO NOT use the clamps in situations contrary to national safety or accident laws • DO NOT combine the clamps with non-compliant accessories • modifying them in the structure or in the form • DO NOT use the clamps in equipment intended for the transport or lifting of persons or animals • DO NOT exceed the loads indicated in the table • DO NOT ignore the instructions for use regarding the correct selection or arrangement of the device to which the clamps will be connected with • DO NOT use the wire rope clips in tension with equipment that can change its own static configuration, the barycentre or the chemical state • DO NOT use the clips to join together two pieces of rope by welding it with metal parts or by intervening with welding fillings or using it as a mass for welding machines • DO NOT use the clips with plastic covered wire ropes, or for the construction of buttonholes to be used in lifting, do not use the clips connecting them to equipment of size, temperature point of coupling and shape not suitable for its characteristics, do not use them in situations of failure or incorrect maintenance Limitations DO NOT use the clamps • when the tightening torque is higher than indicated • as structural failures can occur on the U-bolt • when a smaller number of terminals is applied to how much indicated • at temperatures other than those indicated • when the force guideline does not extend along the main axis of the rope
1
1 Ø8-Ø6 Ø6-Ø4
C
B
2 3
D
A
H
3
G
2
F E
Code
89002 ENEL 263202 Ø4-Ø6
89001 TELECOM 02076-8 Ø6-Ø8
A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) G (mm) H (mm) Peso (gr) Tinst (Nm) N Tz
M6 31 17 16,8 30 16 14 10 35 4,24 3 -
M8 42 25 20 37 22 20 13 70 10 3 240
N = min. numbers of clips to be installed Tinst = max tightening torque to be used
169
heavy duty anchors
Vorpa Steel buckle accessories
Products group
Eye and eye turn buckle
Hook and eye buckle
Suitable for • Wire ropes • Cables • Tie rods • Ropes
Characteristics • Forged turn buckle
Suitable to fix • Radio systems cables • TV systems cables • Tie rods for orchards • Wire clotheslines • Tensioning cables
Technical data Code
1260 1261 1262 1263 * 1264 * * * * * * * * * * *
D mm
A mm
B mm
C mm
E mm
F mm
G mm
L mm
Max load kg
Coeff.
M5 M6 M8 M10 M11 M12 M14 M16 M18 M20 M22 M24 M27 M30 M33 M36 M39
35 44 52 62 68 70 85 90 98 105 118 130 135 135 148 158 170
8 11 11 14 15 16 18 23,5 25 26 28 28 31 31 36 42 49
16 19 22 28 33 33 36 48 51 57 60 65 71 71 88 94 104
9 10 13 14 18 18 20 22 27 27 28 30 49 56 56 55 58
49 59,5 71 90 90 91,5 113 132 135,5 156,5 160 179,5 188,5 188,5 201 230 238
7 8 10 12 15 15 17 19 20 20 23 25 31 31 34 44 44
80 90 110 125 120 140 170 190 200 220 240 260 300 310 310 295 330
25 45 75 115 140 150 210 340 450 650 900 1200 1400 1500 1750 2000 2250
4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
Coeff. = Safety factor to be applied
* on request
L G
B C E D
A F
L B C E D
L
A F
G
B C E D
Code
1250 1251 1252 1253 * 1254 * * * * * * * * * * * * *
D mm
A mm
B mm
C mm
E mm
F mm
L mm
Max load kg
Coeff.
M5 M6 M8 M10 M11 M12 M14 M16 M18 M20 M22 M24 M27 M30 M33 M36 M39 M42 M45
35 44 52 62 68 70 85 90 98 105 118 130 135 135 148 158 170 170 170
8 11 11 14 15 16 18 23,5 25 26 28 28 31 31 36 38 42 50 50
16 19 22 28 33 33 36 48 51 57 60 65 71 71 88 94 104 110 110
9 10 13 14 18 18 20 22 27 27 28 30 49 56 56 55 58 66 66
49 59,5 71 90 90 91,5 113 132 135,5 156,5 160 179,5 188,5 188,5 201 230 238 245 245
80 90 110 125 120 140 170 190 200 220 240 260 300 310 310 295 330 340 340
100 150 300 470 580 650 800 1250 1500 1800 2250 2800 3500 4000 4500 5000 6000 7000 8000
4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
170
A F
L B C E D
A F
heavy duty anchors
Vorpa Accessories fixing accessories Products group
Pressed threaded eye with nut and washer
Pressed threaded eye
A2 stainless steel pressed threaded eye
• Suitable for each applications with chemical anchors and mechanical anchors
• Ideal for various applications • Available also with nut and washer
Technical data Pressed threaded zincplated eye
Code
* 994 * * 995 * 996 * 997 * * 998 * 999
ØDxB thread x length
L thread
A length
E
M5x45 M5x50 M6x45 M6x55 M6x60 M8x57 M8x65 M10x68 M10x81 M10x101 M12x74 M12x98 M14x93 M16x100
40 48 40 50 55 52 60 60 73 93 66 90 85 95
60.7 65.7 64.6 74.6 79.6 78.6 86.7 94.1 107.1 127.1 106.3 130.3 127.1 145.3
52.7 57.7 54.6 64.6 69.6 67.4 75.4 80.6 93.6 113.6 89.5 113.5 109.4 122.1
15.3/16.7 15.3/16.7 18.3/19.7 18.3/19.7 18.3/19.7 21.8/23.2 21.8/23.2 26.0/28.0 26.0/28.0 26.0/28.0 32.5/34.5 32.5/34.5 34.5/36.5 44.8/47.2
G min/max
F min/max
S min/max
8.05/8.55 3.20/3.80 8.05/8.55 3.20/3.80 9.75/10.25 3.90/4.50 9.75/10.25 3.90/4.50 9.75/10.25 3.90/4.50 10.75/11.25 4.90/5.50 11.55/12.05 4.90/5.50 14.25/14.75 6.15/6.85 14.25/14.75 6.15/6.85 14.25/14.75 6.15/6.85 16.75/17.25 8.15/8.85 16.75/17.25 8.15/8.85 17.75/18.25 8.30/9.10 22.70/23.30 12.10/12.90
Max load kg
L G
ØD
480
A
E
B
696
F 1360
S
2020 2966
Racommended safety factor not less than 3
4290 5680
* on request A2 stainless steel pressed threaded eye
Code
995i * * * * 996i * 997i * 998i
ØDxB thread x length
L thread
A length
E
G min/max
F min/max
S min/max
M6x55.5 M6x60.5 M6x65.5 M8x61.5 M8x66.5 M8x71.5 M10x67.0 M10x80.0 M12x73.5 M12x97.5
50 55 60 55 60 65 60 73 66 90
75.0 80.0 85.0 83.0 88.0 93.0 97.0 11.0 107.0 131.0
65.0 70.0 75.0 72.0 77.0 82.0 81.5 94.5 89.5 113.5
19.2/20.8 19.2/20.8 19.2/20.8 21.2/22.8 21.2/22.8 21.2/22.8 30.0/32.0 30.0/32.0 34.0/36.0 34.0/36.0
9.7/10.3 9.7/10.3 9.7/10.3 10.7/11.3 10.7/11.3 10.7/11.3 13.6/14.4 13.6/14.4 15.6/16.4 15.6/16.4
5.2/5.8 5.2/5.8 5.2/5.8 6.0/6.6 6.0/6.6 6.0/6.6 8.2/9.0 8.2/9.0 8.6/9.4 8.6/9.4
* on request
171
Max load kg
2100
2915 4540 7020
Racommended safety factor not less than 3
heavy duty anchors
Vorpa Accessories fixing accessories Products group
Pressed threaded hook
A2 stainless steel pressed threaded hook
Pressed threaded hook with nut and washer
Technical data Pressed threaded zincplated hook
ØD
Code
L thread
A length
B
E
H
ØI
Max load kg
H E
ØI
ØD L
* 1070 * * 1010 * 1011 * * 1012 * 1013 *
M5 M5 M6 M6 M6 M8 M8 M8 M10 M10 M12 M12 M14
40 48 40 50 55 52 60 80 60 73 66 90 82
62.0 71.5 67.0 77.0 82.0 90.0 98.0 118.0 103.5 116.5 122.0 146.0 144.0
53.6 63.0 55.5 65.5 70.5 75.5 83.5 103.5 87.5 100.5 101.5 125.5 120.5
17.5 17.5 22.5 22.5 22.5 30.0 30.0 30.0 36.0 36.0 47.0 47.0 48.0
6.0 6.0 8.0 8.0 8.0 10.0 10.0 10.0 12.5 12.5 16.0 16.0 16.0
7.5 7.5 9.5 9.5 9.5 11.0 11.0 11.0 14.0 14.0 18.0 18.0 17.0
173
A
B
241
387 547 1057
Racommended safety factor not less than 3
1342
* on request A2 stainless steel pressed threaded hook
Code
1010i * * 1011i * 1012i * 1013i
ØD
L thread
A length
B
E
H
ØI
M6 M6 M8 M8 M10 M10 M12 M12
50 55 55 60 60 73 66 90
77.0 82.0 93.0 98.0 103.5 116.5 122.0 146.0
65.5 70.5 78.5 83.5 87.5 100.5 101.5 125.5
22.5 22.5 30.0 30.0 36.0 36.0 47.0 47.0
8.0 8.0 10.0 10.0 12.5 12.5 16.0 16.0
9.5 9.5 11.0 11.0 14.0 14.0 18.0 18.0
Max load kg
241 387 547
Racommended safety factor not less than 3
1057
* on request Code
1054
Description
GF 10/95
threaa
thread length mm
Ø hole
M10
75
12
Gancio GF threaded square hook
172
Universal and frame fixings
universal and frame fixings
Vorpa THERMOISO PLUS
innovative anchorage system for masonry coated by heatinsulating panels and insulation materials.
Concrete
Natural stone
Solid brick
Perforated brick
Hollow brick
Cellular concrete
Aerated concrete
Products group Suitable for • concrete • natural stone • solid brick • perforated brick • hollow brick • cellular concrete • aerated concrete
To fix • blinds • hinges • rain descendants • shelters • curtains
Product information Benefits • Innovative anchorage system for masonry coated by heatinsulating panels and insulation materials. • High mechanical strength even on panels lined with panels high thickness insulators. • Elimination of the so-called “thermal bridge” internal-external, ie prevents thermal dispersions in edifices, condensates and molds. • Thermoiso Plus is universal, it can be used on any type of masonry, both full and perforated. • Quick, practical and intuitive application does not require any particulars equipment, only one drill-machine, a drill bit and a chemical cartridge • Drilling diameter reduced compared to conventional methodologies. • The thermoiso system is convenient because it offers a solution to ideal fixation at a low cost. it is advisable to use an adhesive sealant on the back of the support ring to prevent any water infiltration in the panel.
Fixing system consisting of: 2mm thick wrought iron sheet structure and punched M12 and M16 threaded rod, welded to provide extra load resistance. Zinc coating electrolytic for corrosion protection. The system allows applications on insulated walls with a thickness of 60 mm to 145 mm (160 mm on compact walls). It is also possible to use it on larger coats reducing the shear load; polyamide sleeve specially designed to accommodate M8, M10 or M12 accessories and Ø 6 to Ø12 wood screws. Avoids the contact of the threaded with the bearing structure in metal, eliminating the thermal bridge between the interior and exterior of the building. The support ring gives a pleasant aesthetic finish and allows perfect alignment to the wall; special perforated sleeve for anchoring with injection resins on perforated walls (on compact masonry is not required
Examples of applications
Hinges and general frames
Roofs and canopies
Rainwater pipes
Wall parabolic dishes
External air conditioners
Wall heaters
174
universal and frame fixings
Vorpa THERMOISO PLUS
innovative anchorage system for masonry coated by heatinsulating panels and insulation materials.
Concrete
Natural stone
Solid brick
Perforated brick
Hollow brick
Cellular concrete
Aerated concrete
Installation sequence Application sequence of Thermoiso Plus on hollow materials with perforated sleeve 3)
Max 145 mm Max 145 mm
1)
3)
1) 2) 2)
Application Max sequence of Thermoiso Plus on solid materials
3) 1)
160 mm Max 160 mm
3)
1) 2) 2)
Technical data
A B
Code
C
Description
A) Total length mm
B) Max insulation panel thickness mm
C) Thread length mm
Ø Hole on hollow brick mm
Ø Hole on solid brick mm
58742 Thermoiso Plus 6 58743 Thermoiso Plus 8
217 217
140 140
80 80
16 16
16 16
58740 Thermoiso Plus M10 58741 Thermoiso Plus M12
240 240
145 (160)* 145 (160)*
90 90
20 20
20 20
* On solid brick, the threaded bar can be inserted into the supporting masonry with a minimum depth of 75 mm. so you can consider a max thickness of insulation panel of 160 mm.
art. 58742 for wood screws Ø6 - Ø7
art. 58740 for metric screws M10 and wood screws Ø10
art. 58743 for wood screws Ø8 - M8
art. 58741 for metric screws M12 and wood screws Ø12
Accessories Hinges
Firm shutters
Threaded screw
Threaded bar
Wood screws
Double thread screw
M10 - M12
Ø6 - Ø7 - Ø8
M8 - M10 - M12
M8 - M10 - M12
Ø7 - Ø8 - Ø10 - Ø12
Ø6 - Ø8 - Ø10 - Ø12
175
universal and frame fixings
Vorpa THERMOISO PLUS
innovative anchorage system for masonry coated by heatinsulating panels and insulation materials.
Concrete
Natural stone
Solid brick
Accessories
Perforated sleeves CVX
Code
Adhesive sealant
Description
Content
ml 58732 Perforated sleeve CVX Ø16x85 per Thermoiso Plus 6 e 8 58731 Perforated sleeve CVX Ø20x100 per Thermoiso Plus M10 e M8 23001 Adhesive sealant MS-POLYMER SiMP•SEAL 55
290
Chemical anchor CV.PSF
Code
Description
1124 CV.PSF 300 1002P CV.PSF 410 1005 Mixer
Content
Mixer
ml 300 410
n° 1 1
Suitable for
Weigth kg
CV.PSF 300
0,7
CV.PSF 410
1
Manual caulking gun
Code
Description
1009 Metal caulking gun 300 ml professional 2,5 kN 1101 Metal caulking gun 410 ml professional 2,5 kN
Dust cleaning manual pump
Code
Cleaning brush
Description
1072 Dust cleaning manual pump
length mm. 225
1049 Cleaning brush holes Ø 10 - Ø 20 1059 Cleaning brush holes Ø 20 - Ø 30
brush length mm 100 brush length mm 100
176
Perforated brick
Hollow brick
Cellular concrete
Aerated concrete
universal and frame fixings
Vorpa THERMOISO PLUS
innovative anchorage system for masonry coated by heatinsulating panels and insulation materials.
Concrete
Natural stone
Solid brick
Perforated brick
Hollow brick
Cellular concrete
Aerated concrete
Thermoiso Plus - anchorage system for masonry coated by heat-insulating panels and insulated materials Loads on concrete and solid material Shear 2)
Thermoiso Plus 6-Ø16 - Wood screws Ø 5x50 Thermoiso Plus 6-Ø16 - Wood screws Ø 6x60 Thermoiso Plus 6-Ø16 - Wood screws Ø 7x85 Thermoiso Plus 8-Ø16 - Hexag. head screw Ø 8x80 Thermoiso Plus M10-Ø20 - Metric hexag. screw M10x803) Thermoiso Plus M12-Ø20 - Metric hexag. screw M12x803)
Pull out 1)
Tfix 50 mm
Tfix 60 mm
Tfix 70 mm
Tfix 80 mm
Tfix 90 mm
Tfix 100 mm
Tfix 110 mm
Tfix 120 mm
Tfix 130 mm
Tfix 140 mm
Tfix 150 mm
Tamm
Vamm
Vamm
Vamm
Vamm
Vamm
Vamm
Vamm
Vamm
Vamm
Vamm
Vamm
Smin
Cmin
daN
daN
daN
daN
daN
daN
daN
daN
daN
daN
daN
daN
mm
mm
60
56
53
50
48
46
44
42
28
25
20
80
80
90
80
70
60
40
50
45
40
35
30
25
80
80
165
155
145
135
125
117
110
105
95
80
65
100
100
Minimum Edge axial distance spacing
20 50 80 90 90 90
1daN ≈ 1Kg
Tfix ≈ insulation panel thickness
Load perforated brick (Poroton) Shear 2)
Thermoiso Plus 6-Ø16 - Wood screws Ø 5x50 Thermoiso Plus 6-Ø16 - Wood screws Ø 6x60 Thermoiso Plus 6-Ø16 - Wood screws Ø 7x85 Thermoiso Plus 8-Ø16 - Hexag. head screw Ø 8x70 Thermoiso Plus M10-Ø20 - Metric hexag. screw M10x803) Thermoiso Plus M20-Ø20 - Metric hexag. screw M12x803) 1daN ≈ 1Kg 1) Tensile
Pull out 1)
Tfix 50 mm
Tfix 60 mm
Tfix 70 mm
Tfix 80 mm
Tfix 90 mm
Tfix 100 mm
Tfix 110 mm
Tfix 120 mm
Tfix 130 mm
Tfix 140 mm
Tfix 150 mm
Tamm
Vamm
Vamm
Vamm
Vamm
Vamm
Vamm
Vamm
Vamm
Vamm
Vamm
Vamm
Smin
Cmin
daN
daN
daN
daN
daN
daN
daN
daN
daN
daN
daN
daN
mm
mm
60
56
53
50
48
46
44
42
28
25
20
80
80
90
80
70
60
40
50
45
40
35
30
25
80
80
120
112
105
97
90
85
80
75
70
62
45
100
100
20 50 65 75 60 60 Tfix ≈ insulation panel thickness
loads include an appropriate safety coefficient Test reports available
2) Cut-off
loads are considered as a function of a maximum displacement of 3mm. For more information on higher displacement, contact Vorpa Technical Support. 3) Data
Minimum Edge axial distance spacing
refer to tests performed with UNi metric screws 5739 class 8.8 with insertion depth inside the 60 mm thermal insulation sleeve.
177
universal and frame fixings
Vorpa THERMOISO PLUS
innovative anchorage system for masonry coated by heat-insulating panels and insulation materials.
EXTRACT FROM TEST REPORT N. 337967 OF 25/11/2016 Calculation of thermal transmittance for thermal insulation coat (Ethics) bymeans of the Finite Element Method, in accordance with UN in EN 6946: 2008 and UN and EN isO 10211: 2008
[°C]
[°C]
20
20
19
19
18
18
17
17
16
16
15
15
14
14
13
13
12
12
11
11
10
10
9
9
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
0
0
[°C] 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
The exact thermal transmittance value present at the anchorage system, in a masonry plastered internally and externally with a thickness of 15 and 5 mm respectively, with a total thickness of 330 mm (made of 250 mm thick brick elements and with 60 mm of thick external insulation panels) and thermal conductivity 0.034 W / (m · K); It results to be
X = 0,012 W/K 178
universal and frame fixings
Safety witholding hooks for tiles and ceramic slabs mounted in façade with adhesive The glued façade is a system that makes it possible to get good-looking results and less recurring maintenance than other equivalent systems. This type of covering uses adhesive to attach ceramic slabs directly onto the plaster of the building exterior. However, to ensure the laying of slabs over 30cm it is necessary to adopt an additional safety devise against detachment of the adhesive due to tensions arising from structural adjustments, stretching and extension to thermal excursions, earthquake shakings, etc.
•plug
•plug with screw
The concealed Vorpa Click-Up system is a patented device that ensures the connection of the ceramic slab to the wall by an invisible mechanical hook inserted in the slab itself through an engrave before laying. After having covered the slab with glue and installed it, the hook is subsequently secured to the wall by a plug.
•wall
The Vorpa Click-Up system provides pull-out load over 350kg* for each application point stated by specific laboratory tests. This allows great safety in case of detachment of the glue between wall and slab together with fast and practical installation.
(*Click-Up M-type on 11mm porcelain tiles with adhesive).
•slab
•engrave
Vorpa Click-Up safety hooks are made of 0,5mm AISI304 stainless steel in four different sizes according to thickness of slabs (minimum 6mm). They are supplied ready for assembly to back side slabs once made the incision by Click-Cut grooving toll.
•Click-Up
•adhesive
D
TE N E T A P
179
universal and frame fixings
Vorpa CLICK-UP
Safety witholding hooks for tiles and ceramics mounted in façade with adhesive Tile length
Pieces per tile (A)
10 ≤ 60 cm 60 ≤ 150 cm 150 ≤ 240 cm 240 ≤ 320 cm
Click-Up recommended load (B)
daN
Size S (small)
Size M (medium)
Size L (large)
Size XL (extra large)
45 daN
55 daN
60 daN
65 daN
1 2 3 4
Pieces per box
500
1 daN=1kg
(A) The number of hooks is indicative. However, it is recommended being the designer to identify the number of hooks for tile/slab according to dimensions, base material, local regulations and environment conditions. (B) Recommended loads are stated applying a safety factor equal to 4.
Art. 4086
CLICK-UP serie S (small) Click-Up size S (small)
Art. 4087
CLICK-UP Click-Upserie sizeMM(medium) (medium)
30
30
0,5
0,5
CLICK-UP
CLICK-UP
CLICK-UP
CLICK-UP
9
9
9
9
9
9 8,5
8,5
100
8,5 8,5
8,5
35°
13
r1
5
9 8,5
8,5
8,5
8,5
8,5 8,5
8,5
13
5,6
8,5 8,5
8,5
8,5
9 8,5
99
8,5
101
30
0,5
8,5
r1
Art. 4089
CLICK-UP Click-Up serie size XL XL (extra-large) (extra large)
30
0,5
35°
Art. 4088
CLICK-UP seriesize L (large) Click-Up L (large)
97
Tested by
35°
35°
13
8,5
13
r1
r1
9
7,2
Installation sequence 1
Engraving slab by grooving tol Click-Cut 2
Insert the hook in the engrave
Slab back side 3
4
Laying the glue on the slab and wall
5
Fix the hook with plug and screw
Art 4099 Click-cut grooving tool
Slab front side
Work completed
180
Install the slab to the wall with glue
universal and frame fixings
Vorpa CLICK-UP
Safety witholding hooks for tiles and ceramics mounted in façade with adhesive accessories
Threaded bar for application on masonry coated with insulating panels
Code
Description
Internal thread
Max thickness of insulating panel mm
Min. embedment depth on masonry mm
Ø hole on hollow masonry mm
Ø hole on solid masonry mm
M6x14 M6x14 M6x14
80 100 120
80 80 80
16 16 16
14 14 14
91038 Threaded bar Ø12x160 91075 Threaded bar Ø12x180 91042 Threaded bar Ø12x200 Other sizes on request
Perforated plastic sleeve CVX to be used on hollow masonry
Code
Description
58732 Perforated sleeve CVX Ø16x85
Ø hole on hollow masonry
mm Ø16
Chemical anchor CV.PSF
Code
Description
1124 CV.PSF 300 1002P CV.PSF 410 1005 Mixer
Content
MIxer
ml 300 410
n° 1 1
Examples of installation Insulating panels on solid masonry
Insulating panels on hollow masonry
181
universal and frame fixings
Vorpa CLICK-CUT grooving tool
B D A C
A
Wing nut to adjust the slab thickness and block.
B
Wing nut to adjust the cutting inclination, the right inclination of Click-Cut flute Device for engraving slabs is 55° for each size Click-Up hook.
C
Flange to adjust the cutting position.
D
Wing nut to adjust the cutting depth.
182
universal and frame fixings
Vorpa VK
4 segments nylon plug
Concrete
Solid brick
Perforated brick
Hollow brick
Plasterboard
Light construction materials
Products group VK
VK V with chipboard screw
Suitable for • Concrete • Solid brick • Perforated brick • Hollow brick • Plasterboard • Light construction materials • Perforated cement
To fix • Light carpentry • Curtains slide guides • Bath accessories • Lamps, paintings • Post boxes • Satellite dishes • Wall cupboards
VK C with pan head screw
VK T with hexagonal head screw and washer
Examples of applications
Product information Characteristics • 4 way expansion form nylon plug
Installation • To be mounted aligned the wall
Benefits • Easy and quick fixings thanks to the four segments of the body • Anti-rotation lugs stop the plug rotating in the drill hole • The fixing’s collar prevents it slipping into the drilled hole • Nylon safety and reliability • Temperature resistant from -40°C to +80°C • To be used with wood and clipboard screws
Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation
183
Perforated cement
universal and frame fixings
Vorpa VK
4 segments nylon plug
Concrete
Solid brick
Perforated brick
Hollow brick
Plasterboard
Light construction materials
Installation sequence Solid materials
Hollow materials
Technical data
VK nylon plug
Code
4720 4721 4722 4723 4725 4726
Description
d0 mm
Lt mm
h1 mm
h1 mm
VK 5 VK 6 VK 8 VK 10 VK 12 VK 14
5 6 8 10 12 14
25 30 40 50 60 70
35 45 55 65 80 90
3÷4 4÷5 4,5÷6 6÷8 8÷10 10÷12
Lt h1 d0 Tfix Øv Lv
= Plug length = Min. hole depth = Hole diameter = Fixture thickness = Screw diameter = Screw length
Screw length Lv = Lt + Tfix + Øv
VK V with chipboard screw
Code
4735 4736 4737 4738
Description
VK V VK V VK V VK V
5 6 8 10
d0 x Lt mm
h1 mm
Tfix mm
Øv x Lv mm
5 x 25 6 x 30 8 x 40 10 x 50
35 45 55 65
5 10 10 10
3,5 x 30 4,5 x 40 5 x 50 6 x 60
184
Perforated cement
universal and frame fixings
Vorpa VK
4 segments nylon plug
Concrete
Solid brick
Perforated brick
Hollow brick
Plasterboard
Light construction materials
Technical data
VK C with pan head screw
Code
Description
d0 x Lt mm
h1 mm
Tfix mm
Øv x Lv mm
4720C 4721C 4722C
VK C 5 VK C 6 VK C 8
5 x 25 6 x 30 8 x 40
35 45 55
5 10 10
3,5 x 30 4,2 x 40 4,8 x 50
VK T with hexagonal head screw and washer
Code
Description
4722T 4723T 4725T 4726T
VK T VK T VK T VK T
8 10 12 14
d0 x Lt mm
h1 mm
Tfix mm
Øv x Lv mm
Ch mm
8 x 40 10 x 50 12 x 60 14 x 70
55 65 80 90
5 10 10 5
6 x 45 7 x 60 8 x 70 10 x 80
10 12 13 17
Installation data Tensile resistance in daN with wood screws Ø screws (mm) Concrete C20/25 Solid brick** Double brick UNI with plaster** Gasbeto > G4
1 daN ≃1 kg VK 5 4 180 150 40
VK 6 5 280 150 80 50
VK 8 6 300 200 80 50
VK 10 8 800 400 150 110
VK 12 10 1200 460 130
VK 14 12 2400 -200
ATTENTION: An appropriate safety factor = 5 should be applied on these values. As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.
185
Lt h1 d0 Tfix Ø v Lv Ch
= Plug length = Min. hole depth = Hole diameter = Fixture thickness = Screw diameter = Screw length = Spanner
Perforated cement
universal and frame fixings
Vorpa TV Z
Universal nylon plug
Concrete
Solid brick
Perforated brick
Hollow brick
Aerated concrete
Perforated cement
Products group TV Z
TV Z V with chipboard screw
Suitable for • Concrete • Solid brick • Perforated brick • Hollow brick • Aerated concrete • Perforated cement
TV Z V A2 with stainless steel chipboard screw
To fix • Window and door frames • Light structural works • Wooden substrucrures • Handrail • Light carpentry • Curtains slide guides • Bath accessories • Lamps, paintings • Post boxes • Satellite dishes • Wall cupboards
Installation sequence On compact materials
Make a drill hole with a hammer drill
Clean the hole
Place the fixture and then insert the anchor into the hole
Put the anchor by hammering softly on the screw head until the fixture stops the nylon plug
Make sure that the fixture is supported by the anchor (nylon plug and screw)
Clean the hole
Place the fixture and then insert the anchor into the hole
Put the anchor by hammering softly on the screw head until the fixture stops the nylon plug
Sent the screw by screw driver or by hand. Make sure that the fixture is supported by the anchor (nylon plug and screw)
Hollow materials
Make a drill hole with a hammer drill
Product information Characteristics • Multi-purpose anchor, suitable for all base materials. Concrete and solid masonry materials, by fully radial expansion perforated masonry, by multiple radial expansion hollow masonry, by knotting
Benefits • Multiple radial expansion behaviour on perforated masonry • Knotting behaviour on hollow masonry • Temperature resistant from -40°C to + 80°C
Benefits • Special wings to avoid turning The special anti-rotation wings on the nylon sleeve provides easy and safe installation on all types of material, avoiding any rotation of the nylon sleeve while the screw is installed • No waiting time before loading • Ideal for fixing of facade, frames and general fastenings • Fully radial expansion behaviour on concrete and solid masonry
Installation • To be mounted aligned the wall Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation
186
universal and frame fixings
Vorpa TV Z
Universal nylon plug
Concrete
Solid brick
Perforated brick
Hollow brick
Aerated concrete
Perforated cement
Technical data
TV Z LUNGO
Code
4739 4740 4741 4742
Description
hmin mm
d0 x Lt mm
screw mm
h1 mm
Tfix mm
hef mm
df mm
TV Z 6x32 TV Z 6x45 TV Z 8x42 TV Z 8x52
60 60 70 70
6x32 6x45 8x42 8x52
4,5 4,5 5,0 5,0
45 55 60 65
2 12 3 13
30 30 39 39
7 7 9 9
TVZ with chipboard screw
Code
4743 4744 4745 4746
Description
hmin mm
d0 x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
hef mm
df mm
TV Z V TV Z V TV Z V TV Z V
60 60 70 70
6x32 6x45 8x42 8x52
4,5x40 4,5x50 5,0x50 5,0x60
45 55 60 65
2 12 3 13
30 30 39 39
7 7 9 9
6x32 6x45 8x42 8x52
TVZ V A2 with stainless steel chipboard screw
Code
4747 4748 4749 4750
Description
hmin mm
d0 x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
hef mm
df mm
TV Z V TV Z V TV Z V TV Z V
60 60 70 70
6x32 6x45 8x42 8x52
4,5x40 4,5x50 5,0x50 5,0x60
45 55 60 65
2 12 3 13
30 30 39 39
7 7 9 9
A2 6x32 A2 6x45 A2 8x42 A2 8x52
187
Lt = Anchor length h1 = Min. hole depth d0 = Hole depth Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Diameter of clearance hole in the fixture hmin = Minimum fixture thickness h = Minimum thickness equal to the thickness of member (hnom, red) and thickness of fixture (Tfix) hef = Embedment depth
universal and frame fixings
Vorpa TV Z
Universal nylon plug
Concrete
Solid brick
Perforated brick
Hollow brick
Aerated concrete
Perforated cement
Installation data Characteristic values to tensile load in daN
1 daN ≃1 kg
Substrate materials Ø screws (mm) Concrete C20/25 Autoclaved aerated concrete 3 N/mm2 Vulcanic tuff 7,5 N/mm2 Hollow brick 1,5 N/mm2 Solid brick 2,5 N/mm2 Hollow concrete thickness member equal to 2 cm
TV Z Ø6 Ø 4,5 390 60 70 79 48 53
TV Z Ø8 Ø5 63 24 11 86 56 63
Tensile and shear loads shown in the table are CHARACTERISTIC LOADS from tests carried out on non-cracked concrete C20/25 without edge and spacing effect (Pull out and shear loads are in kN: 1KN = 100Kg.) CHARACTERISTIC LOADS can be used for Ultimate limit state design of anchorages for use in concrete according to ETAG020-Part C. In case of concrete with a strength class lower than C20/25, or in case of further types of masonry, additional and special tests before installing are required.
ATTENTION: An appropriate safety factor = 5 should be applied on these values.
Examples of applications
188
universal and frame fixings
Vorpa VN
anti-rotation nylon plug 2 way expansion
Concrete
Solid brick
Products group
Flanged body VN
VN
VN a with chipboard screw
VN C with chipboard screw
VN 4 with zincplated hook
VN T with hexagonal head screw and washer
Suitable for • Concrete • Solid brick • Natural stone
To fix • Light carpentry • Curtains slide guides • Bath accessories • Lamps, paintings • Post boxes • Satellite dishes • Wall cupboards • Motion sensors • Information boards
Examples of applications
Product information Characteristics • Anti-rotation nylon plug 2 way expansion
Installation • To be mounted aligned the wall
Benefits • Fast and simple installation • Temperature resistant from -40°C to +80°C • The anti-rotation lock prevents the plug rotation in the drill hole • High level of installation safety • Possibility to direct the expansion forces to let them run parallel to the edge of the building material • To be used with wood and chipboard screws
Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation
189
Natural stone
universal and frame fixings
Vorpa VN
anti-rotation nylon plug 2 way expansion
Concrete
Solid brick
Installation sequence
Technical data
VN B flanged body
Code
435 436 437 438 438S 439
Description
d0 mm
Lt mm
h1 mm
Øv mm
VN B 5 VN B 6 VN B 8 VN B 10/50 VN B 10/60 VN B 12
5 6 8 10 10 12
26 31 41 51 61 61
35 40 55 70 80 75
3÷4 4÷5 4,5÷6 6÷8 6÷8 8÷10
VN
Code
649 630 631 648 632 633 3633 634 635 654
Description
d0 mm
Lt mm
h1 mm
Øv mm
VN 4 VN 5 VN 6 VN 7 VN 8 VN 10/50 VN 10/60 VN 12 VN 14 VN 16
4 5 6 7 8 10 10 12 14 16
20 25 30 30 40 50 60 60 75 80
25 35 40 40 55 70 80 75 85 90
2÷3 3÷4 4÷5 4÷5 4,5÷6 6÷8 6÷8 8÷10 10÷12 12÷14
644 645 646 647
Description
VN C 5 VN C 6 VN C 8 VN C 10
= Plug length = Min. hole depth = Hole diameter = Fixture thickness = Screw diameter = Screw length = Spanner
Screw length Lv = Lt + Tfix + Øv
VN C with chipboard screw
Code
Lt h1 d0 Tfix Ø v Lv Ch
d0 x Lt mm
h1 mm
Tfix mm
Øv x Lv mm
5 x 25 6 x 30 8 x 40 10 x 50
35 40 55 70
1,5 6 5 4
3,5 x 30 4,5 x 40 5 x 50 6 x 60
190
Natural stone
universal and frame fixings
Vorpa VN
anti-rotation nylon plug 2 way expansion
Concrete
Solid brick
Technical data
VN A with chipboard screw
Code
477 478 479 480
Description
VN A 5 VN A 6 VN A 8 VN A 10
d0 x Lt mm
h1 mm
Tfix mm
Øv x Lv mm
5 x 25 6 x 30 8 x 40 10 x 50
35 40 55 70
1,5 6 5 4
3,5 x 30 4,5 x 40 5 x 50 6 x 60
Lt h1 d0 Tfix Ø v Lv Ch
= Plug length = Min. hole depth = Hole diameter = Fixture thickness = Screw diameter = Screw length = Spanner
Screw length Lv = Lt + Tfix + Øv
VN T with hexagonal head screw and washer
Code
850 851 852 853 856 854
Description
VN T 8 VN T 10 VN T 12 VN T 14 /75 VN T 14 /100 VN T 16
d0 x Lt mm
h1 mm
Tfix mm
Øv x Lv mm
8 x 40 10 x 50 12 x 60 14 x 75 14 x 100 16 x 80
55 70 75 90 115 90
5 10 10 10 10 5
6 x 45 7 x 60 8 x 70 10 x 80 10 x 110 12 x 90
VN 4 with zincplated hook
Code
449
Description
VN 4
d0 mm
Lg mm
h1 mm
4
20
25
Installation data Tensile resistance in daN with wood screws Ø screws (mm) Concrete C20/25 Solid brick** Double brick UNI with plaster
VN 4 3 50 115
VN 5 4 200 170 200
1 daN ≃1 kg VN 6 5 300 250 300
VN 8 6 410 400 -
VN 10 8 700 -
VN 12 10 1020 -
VN 14 12 1600 -
VN 16 14 1900 -
ATTENTION: An appropriate safety factor = 5 should be applied on these values. As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.
191
Lt h1 d0 Tfix Ø v Lv Ch Øg Lg
= Plug length = Min. hole depth = Hole diameter = Fixture thickness = Screw diameter = Screw length = Spanner = Hook diameter = Hook length
Screw length Lv = Lt + Tfix + Øv
Natural stone
universal and frame fixings
Vorpa SU P Universal nylon plug
Concrete
Natural stone
Solid brick
Perforated brick
Plasterboard/ Light construction Perforated materials/ Panels cement Aerated Poroton
Products group SU P
SU P with chipboard screw
SU P with pan head screw cross recess
Suitable for • Concrete • Natural stone • Solid brick • Perforated brick • Plasterboard/Panels • Light construction materials/ Aerated Poroton • Perforated cement
To fix • Light carpentry • Curtains slide guides • Bath accessories • Lamps, paintings • Post boxes • Satellite dishes • Wall cupboards
SU P with wire hook
Expansion examples
On compact construction materials
On hollow construction materials and plasterboard / wood panels
Product information Characteristics • Universal multipurpose nylon plug
Installation • To be mounted aligned the wall
Benefits • Easy and quick fixings thanks to the segments of the body • Anti-rotation lugs stop the plug rotating in the drill hole • The fixing’s collar prevents it slipping into the drilled hole • Nylon safety and reliability • Temperature resistant from -40°C to +80°C • High level of installation security
Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation
Installation sequence
192
universal and frame fixings
Vorpa SU P Universal nylon plug
Concrete
Natural stone
Solid brick
Perforated brick
Plasterboard/ Light construction Perforated materials/ Panels cement Aerated Poroton
Technical data
SU P
Code
6900 6901 6902 6903
Description
d0 mm
Lt mm
h1 mm
Øv mm
SU P 6/35 SU P 6/45 SU P 8 SU P 10
6 6 8 10
35 45 50 60
45 55 60 80
3÷3,5 3÷3,5 4÷5 5÷6
SU P with chipboards screw
Code
6912 6913 6914 6915
Description
d0 x Lt mm
h1 mm
Tfix mm
Sc mm
Øv x Lv mm
SU PV 6/35 SU PV 6/45 SU PV 8 SU PV 10
6 x 35 6 x 45 8 x 50 10 x 10
45 55 60 80
10 10 10 20
6 6 6 6
3,5x45 3,5x55 4,5x60 6x80
SU P with pan head screw cross recess
Code
6916 6917 6918
Description
d0 x Lt mm
h1 mm
Tfix mm
Sc mm
Øv x Lv mm
SU PC 6/35 SU PC 6/45 SU PC 8/50
6 x 35 6 x 45 8 x 50
45 55 60
10 10 10
6 6 6
3,5x45 3,5x55 4,5x60
Sc mm
Øv x Lv mm
Øo x Lo mm
6 6
3,5x45 3,5x55
3,9x45 4,4x55
Lt h1 d0 Tfix Øv Lv Sc
= Plug length = Min. hole depth = Hole depth = Fixture thickness = Screw diameter = Screw length = Substrate thickness
SU P with wire hook
Code
6920 6921
Description
d0 x Lt mm
h1 mm
SU PU 6/45 SU PU 8/50
6 x 45 8 x 50
45 60
Tfix mm
Installation data Tensile resistance in daN with wood screws Ø screws (mm) Concrete C20/25 Solid brick** Double brick UNI with plaster** Plasterboard mm 10
1 daN ≃1 kg SU P6 3,5x45/55 100 70 40 35
SU P8 4,5x60 180 140 60 42
ATTENTION: An appropriate safety factor = 5 should be applied on these values.
SU P10 6x80 280 160 80 42
As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.
193
universal and frame fixings
Vorpa VR
Universal multipurpose plug
Concrete
Natural stone
Solid brick
Perforated brick
Aerated concrete
Aerated Poroton
Plasterboard Perforated cement
Products group To fix • Pictures • Lighting • Skirting • Shelves • Mirror cabinets • Letter boxes • Curtain rails • Electrical installation
Suitable for • Concrete • Natural stone • Solid brick • Perforated brick • Aerated concrete • Plasterboard • Aerated Poroton • Perforated cement
VR
VR with chipboard screw
Examples of applications
Expansion examples
On compact construction materials
On hollow construction materials
On plasterboard / wood panels
Product information Installation • To be mounted aligned the wall
Characteristics • Hd polyethylene plug suitable for applications on compact and hollow materials Benefits • Safe and quick fixings • Special anti-rotation wings that prevents the plug turning in the hole on installation • The plug’s neck avoid the introduction of the plug inside the hole • Resistant to temperatures from -40°C to +70°C • To be used with wood screws
Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation
194
universal and frame fixings
Vorpa VR
Universal multipurpose plug
Concrete
Natural stone
Solid brick
Perforated brick
Aerated concrete
Aerated Poroton
Plasterboard Perforated cement
Installation sequence
Technical data
VR
Code
531 532 533
Description
VR 6 VR 8 VR 10
d0 x Lt mm
h1 mm
Øv mm
6 x 38 8 x 51 10 x 61
48 61 71
3÷5 3,5÷7 5÷8
VR with chipboards screw
Code
541 542 543
Description
VR V 6 VR V 8 VR V 10
d0 x Lt mm
h1 mm
Tfix mm
Sc mm
Øv x Lv mm
6 x 38 8 x 51 10 x 61
48 61 71
8 8 8
6 6 6
4x45 5x60 6x70
= Plug length = Min. hole depth = Hole depth = Fixture thickness = Screw diameter = Screw length = Substrate thickness
Screw length Lv = Lt + Tfix + Øv
Installation data Tensile resistance in daN with wood screws Ø screws (mm) Concrete C20/25 Solid brick** Double brick UNI with plaster** Plasterboard mm 10
Lt h 1 d 0 Tfix Øv Lv S c
1 daN ≃1 kg VR 6 4x45 100 70 40 30
VR 8 5x60 160 130 55 40
VR 10 6x70 190 140 75 40
ATTENTION: An appropriate safety factor = 5 should be applied on these values. As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.
195
universal and frame fixings
Vorpa ZV
Nylon light fixing
Concrete
Natural stone
Solid brick
Perforated brick
Aerated Poroton
Aerated concrete
Perforated cement
Products group
ZV with screw
ZV doorstop
ZV short hook
ZV extra long cylinder head screw
ZV medium hook
ZV extra long short hook
ZV long hook
ZV extra long medium hook
ZV eyebolt
ZV extra long eyebolt
ZV wire bolt
ZV extra long wire hook
Suitable for • Concrete • Natural stone • Solid brick • Perforated brick • Aerated Poroton • Perforated cement • Aerated concrete To fix • Curtain slide guides • Lighting, paintings • Post poxes • Satellite dishes • Shelves, profiles • Door stops • Ceilings, hangers • Motion sensors • Bath accessories • Wall mounting for tv and radio
ZV stud and nut
ZV flat hook
ZV adjustable hook
Product information Installation • To be mounted aligned the wall
Characteristics • Nylon wallplug available in three different sizes 6-9-12 mm Ø • Wide range of pre-assembled accessories in zincplated steel • The wallplug expands upon return of the cone, when the accessory is tightened Benefits • The wallplug’s particular shape guarantees effective expansion • The side lugs prevent the wallplug from twisting around on its own axis • The opening along its length guarantees perfect adherence even on non solid materials • The collar prevents stressing claddings • Useful in a wide range of applications • Can be used on most popular building materials
Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation
196
universal and frame fixings
Vorpa ZV
Nylon light fixing
Concrete
Natural stone
Solid brick
Perforated brick
Aerated Poroton
Aerated concrete
Installation sequence ZV with accessories on solid materials
ZV with accessories on hollow materials
ZV with screw
ZV with stud and nut
ZV with door stop
Technical data
ZV with screw
Code
871 975 976
Description
d0 mm
Lt mm
h1 mm
Tfix mm
ZV 6 screw ZV 9 screw ZV 12 screw
6 9 12
30 45 50
48 61 71
5 10 10
197
Lt h1 d0 Tfix
= Plug length = Min. hole depth = Hole diameter = Fixture thickness
Perforated cement
universal and frame fixings
Vorpa ZV
Nylon light fixing
Concrete
Natural stone
Solid brick
Perforated brick
Aerated Poroton
Aerated concrete
Perforated cement
Technical data
ZV short hook
ZV medium hook
ZV long hook
Description
d0 mm
Lt mm
h1 mm
G mm
874 977 978
ZV 6 short hook ZV 9 short hook ZV 12 short hook
6 9 12
30 45 50
45 55 60
8 7 7
979 980
ZV 9 medium hook ZV 12 medium hook
9 12
45 50
55 60
11 11
981 982
ZV 9 long hook ZV 12 long hook
9 12
45 50
55 60
18 22
Description
d0 mm
Lt mm
h1 mm
Ø mm
ZV 6 eyebolt ZV 9 eyebolt ZV 12 eyebolt
6 9 12
30 45 50
45 55 60
8 12 13
Description
d0 mm
Lt mm
h1 mm
Ø mm
ZV 9 wire bolt ZV 12 wire bolt
9 12
45 50
55 60
12 13
Code
ZV eyebolt
Code
877 983 984
ZV wire bolt
Code
985 986
ZV stud and nut 30 mm
ZV stud and nut 50 mm
ZV stud and nut M6
Description
d0 mm
Lt mm
h1 mm
ØbxLb mm
Tfix mm
987 988
ZV 9 stud M4x30 ZV 12 stud M5x30
9 12
45 50
55 60
M4x30 M5x30
10 10
991 993
ZV 9 stud M4x50 ZV 12 stud M5x50
9 12
45 50
55 60
M4x50 M5x50
25 25
992
ZV 12 stud M6x20
12
50
60
M6x20
10
Code
198
Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Ø0 = Eyebolt diameter ØbxLb = Stud diameter x stud length
universal and frame fixings
Vorpa ZV
Nylon light fixing
Concrete
Natural stone
Solid brick
Perforated brick
Aerated Poroton
Aerated concrete
Perforated cement
Technical data
ZV flat hook Code
957 969
ZV adjustable hook Description
d0 mm
Lt mm
h1 mm
G mm
ZV 9 flat hook ZV 12 adjustable hook
9 12
45 50
55 60
14 5
d0 mm
Lt mm
h1 mm
AxB mm
9 9
45 45
55 55
Ø20x25 Ø20x25
ZV doorstop Code
989 990
Description
ZV 9 black doorstop ZV 9 white doorstop
ZV extralong cylinder head screw
Code
Description
d0 mm
Lt mm
h1 mm
Tfix mm
9 12
60 60
70 70
10 10
636 ZV 9 extralong cylinder head screw 638 ZV 12 extralong cylinder head screw
ZV extralong short hook
Code
Description
637 ZV 9 extralong short hook 639 ZV 12 extralong short hook
ZV extralong medium hook
d0 mm
Lt mm
h1 mm
G mm
9 12
60 60
70 70
7 7
ZV extralong eyebolt
ZV extralong wire hook
d0 mm
Lt mm
h1 mm
G mm
667 ZV 12 extralong medium hook 12 973 ZV 12 extralong eyebolt 12 974 ZV 12 extralong wire hook 12
60 60 60
70 70 70
11
Code
Description
P mm
Øo mm
13 13
199
Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Ø0 = Eyebolt diameter ØbxLb = Stud diameter x stud length
universal and frame fixings
Vorpa ZV
Nylon light fixing
Concrete
Natural stone
Solid brick
Perforated brick
Aerated Poroton
Aerated concrete
Perforated cement
Installation data Pull out values in daN ZV 6 Code Aerated poroton Concrete C20/25
1 daN ≃1 kg 871 40 40
*874 40 40
*877 40 40
975 160 220
*977 50 50
*979 50 50
*981 50 50
*983 50 50
*985 50 50
991 160 220
987 160 220
636 160 220
*637 50 50
976 210 350
*978 90 90
*980 90 90
*982 90 90
*984 90 90
*986 90 90
993 210 350
988 210 350
992 210 350
638 210 350
* Bending moment
Pull out values in daN ZV 9 Code Aerated poroton Concrete C20/25
1 daN ≃1 kg
* Bending moment
Pull out values in daN ZV 12 Code Aerated poroton Concrete C20/25
1 daN ≃1 kg
* Bending moment
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values. As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.
200
*639 90 90
*667 90 90
*973 90 90
*974 90 90
universal and frame fixings
Vorpa SV
Universal light fixing
Concrete
Natural stone
Solid brick
Products group
SV with screw
SV doorstop
SV short hook
SV extra long hex head screw
SV medium hook
SV extra long cylinder head screw
SV long hook
SV extra long short hook
SV eyebolt
SV extra long medium hook
SV wire bolt
SV extra long eyebolt
SV stud and nut
SV extra long wire hook
SV stud and nut
Suitable for • Concrete • Natural stone • Solid brick To fix • Curtain slide guides • Lighting, paintings • Post poxes • Satellite dishes • Shelves, profiles • Door stops • Ceilings, hangers • Motion sensors • Bath accessories • Wall mounting for tv and radio
SV adjustable hook
Examples of applications SV flat hook
Product information Characteristics • Steel wallplug available in three different sizes 6-8-9 mm Ø • Wide range of pre-assembled accessories in zincplated steel • The wallplug expands upon return of the cone, when the accessory is tightened
Installation • To be mounted aligned the wall
Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data Benefits • Thanks to a vast assortment of special accessories this wallplug • Clean the hole before the installation is useful in a wide range of applications • Expansion is excellent thanks to the zincplated steel shieldings • The side lugs prevent the wallplug from twisting around on its own axis • The wallplug can be used on most popular building materials 201
universal and frame fixings
Vorpa SV
Universal light fixing
Concrete
Natural stone
Installation sequence SV light fixing with accessories on compact building materials
SV with screw
SV with stud and nut
SV with door stop
SV with adjustable hook
Technical data
SV with screw
Code
1675 1674 675 676
Description
SV 6 screw SV 6 long screw SV 8 screw SV 9 screw
d0 mm
Lt mm
h1 mm
Tfix mm
6 6 8 9
25 25 40 45
35 35 50 55
5 15 10 10
202
Lt h1 d0 Tfix
= Plug length = Min. hole depth = Hole diameter = Fixture thickness
Solid brick
universal and frame fixings
Vorpa SV
Universal light fixing
Concrete
Natural stone
Solid brick
Technical data
SV short hook
SV medium hook
SV long hook
d0 mm
Lt mm
h1 mm
G mm
SV 6 short hook SV 8 short hook SV 9 short hook
6 8 9
25 40 45
35 50 55
8 11 13
679 680
SV 8 medium hook SV 9 medium hook
8 9
40 45
50 55
15 17
681 682
SV 8 long hook SV 9 long hook
8 9
40 45
50 55
22 30
d0 mm
Lt mm
h1 mm
Øo mm
6 8 9
25 40 45
35 50 55
8 13 14
d0 mm
Lt mm
h1 mm
P mm
6 8 9
25 40 45
35 50 55
6 8 9
d0 mm
Lt mm
h1 mm
ØbxLb mm
8 9 9
40 45 45
50 55 55
M4x40 M6x20 M5x40
Code
1677 677 678
Description
SV eyebolt
Code
1683 683 684
Description
SV 6 eyebolt SV 8 eyebolt SV 9 eyebolt
SV wire bolt
Code
1685 685 686
Description
SV 6 wire bolt SV 8 wire bolt SV 9 wire bolt
SV stud M60x20 Code
687 689 688
SV stud M4 - M5
Description
SV 8 stud M4x40 SV 9 stud M6x20 SV 9 stud M5x40
203
Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Ø0 = Eyebolt diameter ØbxLb = Stud diameter x stud length
universal and frame fixings
Vorpa SV
Universal light fixing
Concrete
Natural stone
Solid brick
Technical data
SV flat hook Code
745 747
SV adjustable hook Description
SV 8 flat hook SV 9 adjustable hook
d0 mm
Lt mm
h1 mm
G mm
8 9
40 45
50 55
15 5
d0 mm
Lt mm
h1 mm
AxB mm
9 9
45 45
55 55
Ø20x25 Ø20x25
Lt h1 d0 Tfix G
= Plug length = Min. hole depth = Hole diameter = Fixture thickness = Hook
ZV doorstop Code
756 754
Description
SV 9 black doorstop SV 9 white doorstop
Installation data Pull out values in daN SV 6 Code Concrete C20/25
1 daN ≃1 kg 1675 40
*1677 40
*1683 40
*1685 40
675 300
*677 40
*679 40
*681 40
*683 40
*685 40
687 300
676 370
*678 90
*680 90
*682 90
*684 90
*686 90
688 370
* Bending moment
Pull out values in daN SV 8 Code Concrete C20/25
1 daN ≃1 kg
* Bending moment
Pull out values in daN SV 9 Code Concrete C20/25
1 daN ≃1 kg 689 370
* Bending moment
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values. As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties.
204
universal and frame fixings
Vorpa SV
Universal light fixing
Concrete
Natural stone
Solid brick
Technical data
SV extra long hex head screw
Code
SV extra long cylinder head screw
Description
2860 2861
SV 9 screw TE SV 9 screw TC
SV extra long short hook Code
d0 mm
Lt mm
h1 mm
Tfix mm
9 9
60 60
70 70
10 10
SV extra long medium hook
Description
2862 SV 9 extralong short hook 2863 SV 9 extralong medium hook
d0 mm
Lt mm
h1 mm
G mm
9 9
60 60
70 70
15 20
d0 mm
Lt mm
h1 mm
Øo mm
9
60
70
14
d0 mm
Lt mm
h1 mm
P mm
9
60
70
9
SV extra long eyebolt
Code
Description
2864 SV 9 extralong eyebolt
SV extra long wire hook
Code
Description
2865 SV 9 extralong wire hook
Installation data Pull out values in daN SV 9 extra long fixing Code Concrete C20/25
2860 370
2861 370
1 daN ≃1 kg *2862 90
*2863 90
*2864 90
*2865 90
* Bending moment
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values. As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties.
205
universal and frame fixings
Vorpa VE.O
Steel expansion anchor for ceilings
Concrete
Products group To fix • Ceilings • Hangers • Lightings • Ventilation systems • Suspended ceilings • Cable conduits
Suitable for • Concrete
Installation sequence
Product information Installation • To be mounted aligned the wall
Characteristics • Steel anchor with expansion clip for solid material • Suitable for ceilings and suspended hangers on limited material thickness Benefits • Simple hammerset installation and a short processing time • The extremely short anchor depth prevents reinfocement hits • The expansion clip guarantees a solid hold when fixed in the drill hole, and prevents it falling out during overhead installation • The nail anchor expands automatically under load. The cone is pulled into the expansion clip and expands it against the drill hole wall
Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation
Technical data
Code
559 1559
Description
d0 mm
Lt mm
h1 mm
VE.O 6/50 VE.O 6/60
6 6
50 60
65 75
VE.O 6/50 80
VE.O 6/60 80
Installation data Pull out values in daN Concrete C20/25
1 daN ≃1 kg
ATTENTION: An appropriate safety factor ≥ 4 should be applied on these values.
206
universal and frame fixings
Vorpa HC - HR
Light fixings in zamak for plasterboard
Boards and panels
Plasterboards
Aerated concrete
Products group
HC - L 31 mm
Suitable for • Boards and panels • Plasterboard • Aerated concrete
HC - L 39 mm
To fix • Skirting • Lamps, paintings • Curtains slide guides • Bath accessories • Profiles • Convectors • Information boards • Motion sensors
HR fixing anchor
Product information Installation • To be mounted aligned the wall
Characteristics • Self-threading zamak fixing for plasterboard, panels and light weight substrate materials Benefits • Need to pre-drill • Quick and easy installation work • Can be used with the most wideranging screws, hooks and eye screws. This allows for a broad range of applications • The sharp, self-tapping thread enables a secure, positive fit fixing • High load-bearing capacity • No special setting tool is required • Only a small amount of space is required behind the board (HC) • Suitable for prepositioned installation
Suggestion for use • The installation torque should be limited when using a battery operated screwdriver • Suitable for wood, self-tapping and chipboard screws of 4.0 to 5.0 mm diameter • No suitable for tiled plasterboard
Installation sequence HR
HC
207
universal and frame fixings
Vorpa HC - HR
tassello in zama per cartongesso
Pannelli Lastre
Cartongesso Cemento Cellulare
dati tecnici
Lt mm 31
Art.
520M 522M
Lt mm 39
Descrizione
Lt mm
Tfix mm
Si mm
ØvxLv mm
HC 31 HC 39
31 39
0-15 0-20
35 44
4x25 4,5x30
Lt mm 31
Art.
520V 522
Lt mm 39
2537 2539
Art.
523
Lt = Lunghezza tassello d0 = Diametro foro Tfix = Spessore fissabile Lv = Lunghezza vite Si = Spazio intercapedine LvxØv = Lunghezza vite x diametro vite Lunghezza vite > Lt + Tfix
HC con vite testa calottata
Descrizione
Lt mm
Tfix mm
Si mm
ØvxLv mm
HC TC 31 HC TC 39
31 39
0-15 0-20
35 44
4x25 4,5x30
Lt mm 31
Art.
HC
Lt mm 39
HC con vite testa svasata piana
Descrizione
Lt mm
Tfix mm
Si mm
ØvxLv mm
HC TSP 31 HC TSP 39
31 39
0-15 0-20
35 44
4x25 4,5x30
Descrizione
d0 mm
Lt mm
Tfix mm
Si mm
ØvxLv mm
HR 39
16
39
0-12
40
4,5x45
Installation dati tecnici data per l’installazione Resistenza alla trazione in daN Cartongesso singola parete 9,5 mm Cartongesso singola parete 12,5 mm Cartongesso doppia parete ≥ 25 mm
1 daN ≃1 kg HC 31 30 45 60
HC 39 45 55 70
ATTENZIONE: Si consiglia applicare un coefficiente di sicurezza pari a 5. Consultare la guida tecnica.
208
HC 39 55
universal and frame fixings
Vorpa HZ - HB
Nylon plug for plasterboard
Boards Plasterboards Aerated concrete and panels
Products group To fix • Skirting • Lightings, paintings • Curtains slide guides • Bath accessories • Shelves • Convectors • Motion sensors
Suitable for • Boards and panels • Plasterboard • Aerated concrete
HZ 29
HZ 29 TC
HZ 29 V TSP
HB 30
Product information Characteristics • Self-tapping nylon fixing for plasterboard
Installation • To be mounted aligned the wall
Benefits • No need to pre-drill • Quick and easy installation • Suitable for wood, self-tapping and chipboard screws
Suggestion for use • Not suitable for tiled plasterboard • The installation torque should be reduced when using a battery operated screw driver
Installation sequence
Technical data
Code
Description
Lt mm
Tfix mm
ØvxLv mm
2523s 2523 2755 521
HZ 29 nylon plug HZ 29 V TC nylon plug with cylinder head screw HZ 29 V TSP nylon plug with flat head screw HB 30 V nylon plug with countersunk head screw
29 29 29 30
13 13 13 12
4,5x25 4,5x25 4,5x25 3x25
Installation data Pull out values in daN
1 daN ≃1 kg HZ 40 50 67
Plasterboard 10 mm Plasterboard > 12,5 mm Plasterboard ≥ 25 mm
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.
209
HB 20 30 45
Lt = Plug length Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length Si = Interspace Lv > Lt + Tfix
universal and frame fixings
Vorpa HS
Nylon plug with toggle designed for fixing on hollow materials
Aerated concrete
Hollow brick
Plasterboards
Boards and panels
Products group To fix • Curtain slide guides • Lighting, paintings • Post poxes • Satellite dishes • Shelves, profiles • Door stops • Ceilings, hangers • Motion sensors • Bath accessories • Wall mounting for tv and radio
Suitable for • Aerated concrete • Hollow brick • Plasterboard • Boards and panels HS with toggle
HS V with toggle and chipboard screw
Product information Characteristics • Nylon plug with toggle designed for fixing on hollow materials plasterboard, boards and panels • Suitable for metric and chipboard screws
Installation • To be mounted aligned the wall
Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values Benefits • The expanding arms swing open and press onto the reverse side • Respect the installation data • Clean the hole before the installation of the board • Reduced thermal transfer Installation sequence
Technical data HS nylon plug with toggle Code
Description
1050 HS 10x38 1051 HS 10x47
Lt mm
h1 mm
Øv mm
d0 mm
Tfix mm
38 47
30 42
4 4
10 10
12 19
Lt mm
h1 mm
ØvxLv mm
d0 mm
Tfix mm
38 47
30 42
4x50 4x55
10 10
12 19
HS nylon plug with toggle and chipboard screw Code
Description
1056 HS V 10x38 1057 HS V 10x47
Installation data Pull out values in daN
1 daN ≃1 kg HS 10 40 40
Plasterboard Hollow brick
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values. 210
Lt h1 d0 Tfix Ø v Lv
= Plug length = Min. hole depth = Hole diameter = Fixture thickness = Screw diameter = Screw length
Screw lenght Lv = Lt + Tfix + Øv
universal and frame fixings
Vorpa HU
Metal cavity fixing for plasterboard
Hollow brick
Plasterboards
Boards and panels
Products group Suitable for • Hollow brick • Boards and panels • Plasterboard
Metal cavity fixing HU with screw
To fix • Skirting • Lightings, paintings • Curtains slide guides
Metal cavity fixing HU with hook screw
Metal cavity fixing HU with eye screw
Product information Characteristics • Metal cavity fixing with metric screw Benefits • Quick, easy and secure installation • The metric internal thread allows the attachment to be removed and refitted several times • The expanding arms ensure a large supporting surface • The claws around the edge of the fixing penetrate the board building material, preventing the fixing from rotating
Benefits • Load bearing capacity • During the installation procedure the expanding arms swing open and press onto the reverse side of the board • The metal fixing can be installed using installation pliers. If using a battery operated screwdriver or screwdriver for installation, the pre-assembled screws must be removed first Installation • To be mounted aligned the wall
Installation sequence Examples of applications
211
universal and frame fixings
Vorpa HU
Metal cavity fixing for plasterboard
Hollow brick
Plasterboards
Boards and panels
Technical data
Metal cavity fixing HU with screw
Code
1766 1767 1768 1769 770 771 1775 772 773 774
Description
Lt mm
ØvxLv mm
d0 mm
h1 mm
dp mm
Tfix mm
HU 4/20/7 HU 4/32/7 HU 4/38/7 HU 4/45/7 HU 5/37/9 HU 5/52/9 HU 5/65/9 HU 6/52/10 HU 6/65/10 HU 6/80/10
20 32 38 45 37 52 65 52 65 80
M4 x 28 M4 x 40 M4 x 45 M4 x 52 M5 x 45 M5 x 60 M5 x 72 M6 x 60 M6 x 72 M6 x 92
8 8 8 8 10 10 10 12 12 12
30 42 48 55 47 62 75 62 75 90
2-4 3-8 10-15 18+22 6-10 8-12.5 20-30 7-16 18-26 32-42
14 18 20 20 22 30 25 30 30 30
G
Lt h1 d0 Tfix Øv Lv dp
= Anchor length = Min. hole depth = Hole diameter = Fixture thickness = Screw diameter = Screw length = Panel thickness
Metal cavity fixing HU with hook screw
Code
1116
Description
Lt mm
ØvxLv mm
d0 mm
h1 mm
dp mm
G mm
HU
37
M5 x 45
10
47
6-10
12
5/37/9 G
Ø
Code
1117
Metal cavity fixing HU with eye screw
Description
Lt mm
ØvxLv mm
d0 mm
h1 mm
dp mm
Ø mm
HU 5/37/9 OA
37
M5 x 45
10
47
6-10
12
Code
Description
749 53128
HTU assembly plier HTU eye and bolt adapter
art. 749
Installation data
art. 53128
Pull out values in daN Code Screw - Plasterboard 9,5 mm Screw - Plasterboard 12,5 mm Screw - Plasterboard 19-20 mm Screw - Plasterboard ≥ 25 mm Hook - bending moment Eye bolt - bending moment
1 daN ≃1 kg HU 4 45 45 75 70 70
HU 5 45 45 75 90 90 90
ATTENTION: An appropriate safety factor ≥ 3 should be applied on these values. 212
HU 6 45 45 75 90 110 110
Examples of applications
universal and frame fixings
Vorpa DOUBLE-SIDED TAPE frame and universal fixings product group Suitable for To fix • plasterboard wall • plasterboard panels partition • metal profiles • guides to the paving Benefits: • Double-sided tape in polythene foam for insulation panels • Product waterproof, hotmelt adhesive and fronts in monosiliconati • Specific for noise reduction. To be applied on metal profiles for plasterboard partition walls • Ideal for metal profiles to be applied on non-drillable floors and ceilings • Suitable for joining of plasterboard walls, for the laying of partition walls and in the fixing of guides to the paving
Specific for noise reduction
Examples of application
technical data
Double-sided sealing tape for partition walls Code
* * 58770 58771 *
Width/length
Weigth
Adhesive weigth
polyethylene thickness
Thermal conductivity 40°C
mm 30x20 ml mm 40x20 ml mm 50x20 ml mm 70x20 ml mm 95x20 ml
73 g/m2 73 g/m2 73 g/m2 73 g/m2 73 g/m2
25 ± 10% g/m2 25 ± 10% g/m2 25 ± 10% g/m2 25 ± 10% g/m2 25 ± 10% g/m2
3 mm 3 mm 3 mm 3 mm 3 mm
0,039 W/mK 0,039 W/mK 0,039 W/mK 0,039 W/mK 0,039 W/mK
* Available on request
213
universal and frame fixings
Vorpa PC
Plasterboard and metal profiles special screws
Profiles
Boards and panels
Products group To fix • Metal plates • Thin profiles • Substructures of plasterboard • Connection of metal profiles
Suitable for • Profiles • Metal plates
PC V self-drilling screw with fine thread
PC A self-tapping screw with fine thread and drill tip
PC F self-tapping screw with drill tip and cylindric head
Examples of applications
Product information Characteristics • Self-drilling and self-tapping screws Benefits • The screws are phosphate-threated and thus provide the necessary corrosion protection • Efficient solution for serial machine assembly • Safe and economical • No pre-drilling required Technical data Lt = Plug length Tfix = Fixture thickness Øv = Screw diameter Øt = Head screw diameter Ch = Spanner Tfix = Lv - hef
PC V self-drilling screw with fine thread
Code
2850 2851 2852 2853
Description
PC V 3,5x25 PC V 3,5x35 PC V 3,5x45 PC V 3,5x55
ØvxLv mm
Tfix max mm
Øt mm
Ch mm
3,5x25 3,5x35 3,5x45 3,5x55
1 1 1 1
8 8 8 8
Ph2 Ph2 Ph2 Ph2
PC A self-tapping screw with fine thread and drill tip
Code
2890 2891 2892
Description
PC A 3,5x25 PC A 3,5x35 PC A 3,5x45
ØvxLv mm
Tfix max mm
Øt mm
Ch mm
3,5x25 3,5x35 3,5x45
2,25 2,25 2,25
8 8 8
Ph2 Ph2 Ph2
PC F self-tapping screw with drill tip and cylindric head
Code
2895 2897 2898 2896
Description
PC F 4,2x13 PC F 4,2x16 PC F 4,2x19 PC F 4,2x25
ØvxLv mm
Tfix max mm
Øt mm
Ch mm
4,2x13 4,2x16 4,2x19 4,2x25
3 3 3 3
10,5 10,5 10,5 10,5
Ph2 Ph2 Ph2 Ph2
214
universal and frame fixings
Vorpa WING TOGGLE VB Cavity fixing for hollow materials
Hollow brick
Plasterboards
Products group
VBA
VB E
VB
VBC
Suitable for • Gypsum plasterboard and gypsum fibreboards • Cavity floor slabs made from bricks and concrete • Chipboard • Plywood
VB
VBB
To fix • Lightings, paintings • Ceilings • Mirror cabinets • Light shelves • Pipe clamps • Profiles for slabs
Product information Characteristics • Cavity fixing VBA-VB-VBC-VBE: spring toggle • Cavity fixing VBB and VBD: gravity toggle Benefits • Maximum flexibility • High load-bearing capacity • Suitable for pre-positioned installation • When placed in the drill hole, the bearing elements of the gravity and spring toggles independently swing open behind the board • No special installation tool is required
Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation
Installation sequence
215
Boards and panels
universal and frame fixings
Vorpa WING TOGGLE VB Cavity fixing for hollow materials
Hollow brick
Plasterboards
Boards and panels
Technical data
P Ø0
Spring toggle VBA M4 Code
1670 1671 1672 1673
Description
Øv mm
d0 mm
Sv mm
Sc mm
P mm
Øo mm
VBA M4 SCREW VBA M4 STUD/NUT VBA M4 EYEBOLT VBA M4 WIRE BOLT
M4 M4 M4 M4
12 12 12 12
25 25 25 25
50 60 30 30
12
12,5 -
P
Ø0
Spring toggle VB M5 Code
670 671 672 673
Description
Øv mm
d0 mm
Sv mm
Sc mm
P mm
Øo mm
VB M5 VB M5 VB M5 VB M5
M5 M5 M5 M5
14 14 14 14
27 27 27 27
50 60 30 30
12
15 -
SCREW STUD/NUT EYEBOLT WIRE BOLT
P Ø0
Spring toggle VBC M6 Code
2674 2670 2671 2672 2673
Description
Øv mm
d0 mm
Sv mm
Sc mm
P mm
Øo mm
VBC M6 WING TOGGLE VBC M6 SCREW M6 x 80 VBC M6 STUD M6 x 100 VBC M6 EYEBOLT VBC M6 WIRE BOLT
M6 M6 M6 M6
17 17 17 17
30 30 30 30
40 50 25 25
13
14,5 -
Ø0 Øv d 0 Sc S v P
216
= Eyebolt diameter = Screw diameter = Hole diameter = Thickness of the fixture = Interspace = Passage of the hook
universal and frame fixings
Vorpa WING TOGGLE VB Cavity fixing for hollow materials
Hollow brick
Plasterboards
Boards and panels
Technical data
P Ø0
Gravity toggle VBB M6 Code
1700 703 700 701 702
Description
Øv mm
d0 mm
Sv mm
Sc mm
P mm
Øo mm
VBB M6 WING TOGGLE VBB M6 SCREW M6 x 100 VBB M6 STUD M6 x 100 VBB M6 EYEBOLT VBB M6 WIRE BOLT
M6 M6 M6 M6
15 15 15 15
75 75 75 75
40 60 30 30
13
14,5 -
P Ø0
Spring toggle VBE M8 Code
3674 3670 3671 3672 3673
Description
Øv mm
d0 mm
Sv mm
Sc mm
P mm
Øo mm
VBE M8 WING TOGGLE VBE M8 SCREW M8 x 100 VBE M8 STUD M8 x 100 VBE M8 EYEBOLT VBE M8 WIRE BOLT
M8 M8 M8 M8
20 20 20 20
40 40 40 40
50 50 20 20
10
11,8 -
M10
25
45
Spring toggle VBE M10
5674
VBE M10 WING TOGGLE
P
Gravity toggle VBD M8 heavy duty fixings Code
4674 4671 4673
Description
Øv mm
d0 mm
Sv mm
Sc mm
P mm
VBD M6 WING TOGGLE VBD M6 STUD M8 x 100 VBC M6 WIRE BOLT
M8 M8
20 20
75 75
60 60
16
Installation data Pull out values in daN Spring toggle with screw Spring toggle with stud/nut Spring toggle with eyebolt * Spring toggle with wirebolt *
1 daN ≃1 kg M4 120 120 40 40
M5 230 230 60 60
M6 350 350 100 100
M8 600 600 300 300
* Bending moment ** Fixing on metal profiles
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values. 217
M10 800
M8 VBD 2000** 300
Ø0 Øv d 0 Sc S v P
= Eyebolt diameter = Screw diameter = Hole diameter = Thickness of the fixture = Interspace = Passage of the hook
universal and frame fixings
Vorpa WING TOGGLE VB M10 Cavity fixing hevy duty loads on hollow materials
Hollow brick
Plasterboards
Boards and panels
Products group
Thread M10
Code 5675 WING TOGGLE M10
Code 5676 WING TOGGLE M10 WITH BAR, NUTS, WASHER
Code 5679 For suspended sanitary ware
Product information Characteristics • Steel wing toggle with self-locking folding crosspiece inside the cavity • Suitable for fixings on perforated panels, panels of gypsum-fibra, prestressed concrete with alveolar core, corrugated metal profiles, cavities in general • Allows the application of very heavy loads • Possibility to add other accessories as bolts and eyelets hooks
Suitable for • floors with alveolar core • gypsum fibra • paving in perforated blocks • metal profiling • cavity in general • cavity foor slabs made from bricks and concrete
Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation
To fix • countertops • collars for exhaust pipes • heavy ducts • suspended profiles • suspended sanitary ware
Test reports available
Installation sequence
Installation data Determination of the mean tensile strength of the tilting anchor on a metal profile
VB M10
1 daN ≃1 kg
1080 daN
The type of support has an influence on the strength of the steel anchor. The values show in the table refer to the maximum resistance of the product; it is advisable to adopt an appropriate security coefficient. At least 4.
218
universal and frame fixings
Vorpa WING TOGGLE VB M10 Cavity fixing hevy duty loads on hollow materials
Hollow brick
Plasterboards
Boards and panels
Technical data
Øv Sv
Thread M10 Sc d0
Code 5675 WING TOGGLE M10
code 5676 WING TOGGLE M10 WITH BAR, NUTS, WASHER Øv mm
Code
Description
5675 5676
VBD M10 WING TOGGLE M10 VBD M10 WING TOGGLE M10 WITH BAR, NUTS, WASHER
d0 Sc mm mm
M10 30
80
Øv d0 S c Sv
Sv mm
= Screw diameter = Hole diameter = Thickness of the fixture = Interspace
90
Sc
Sv
d0 Ø
For suspended sanitary ware Code
Description
Øv mm
d0 mm
Sc mm
Sv mm
Lv mm
5679
VBD STUD M10x180 SANITARY WARE
M10
30
80
90
180
Examples of applications
219
Øv d0 S c Sv Lv
= Screw diameter = Hole diameter = Thickness of the fixture = Interspace = Stud length
universal and frame fixings
Vorpa WING TOGGLE VB M10 Cavity fixing heavy duty loads on hollow materials
Hollow brick
Plasterboards
Boards and panels
Products group
Thread M10
Code 5677 WING TOGGLE M10
Code 5678 WING TOGGLE M10 WITH BAR, NUTS, WASHER
Product information Characteristics • Steel wing toggle with self-locking folding crosspiece inside the cavity • Suitable for fixings on perforated panels, panels of gypsum-fibra, prestressed concrete with alveolar core, corrugated metal profiles, cavities in general • Allows the application of very heavy loads • Possibility to add other accessories as bolts and eyelets hooks Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation
Suitable for • floors with alveolar core • gypsum fibra • paving in perforated blocks • metal profiling • cavity in general • cavity foor slabs made from bricks and concrete
To fix • countertops • collars for exhaust pipes • heavy ducts • suspended profiles
Test reports available
Installation sequence
Installation data Determination of the mean tensile strength of the tilting anchor on a metal profile
VB M10
1 daN ≃1 kg
1500 daN
The type of support has an influence on the strength of the steel anchor. The values show in the table refer to the maximum resistance of the product; it is advisable to adopt an appropriate security coefficient. At least 4.
220
universal and frame fixings
Vorpa WING TOGGLE VB M10 Cavity fixing heavy duty loads on hollow materials
Hollow brick
Plasterboards
Boards and panels
Technical data
Øv Sv
Thread M10
Sc d0
Code 5677 WING TOGGLE M10
Code 5678 WING TOGGLE M10 WITH BAR, NUTS, WASHER
Code
Description
Øv mm
d0 mm
Sc mm
Sv mm
5677 5678
VBD M10 WING TOGGLE M10 VBD M10 WING TOGGLE M10 WITH BAR, NUTS, WASHER M10
22
60
90
Examples of applications
221
Øv d 0 Sc Sv
= Screw diameter = Hole diameter = Thickness of the fixture = Interspace
universal and frame fixings
Vorpa HZB
Nylon plug for fixings on light weight concrete blocks
Light construction materials
Products group Suitable for • Lightweight concrete blocks HZB
To fix • Light carpentry • Lamps, paintings • Post boxes • Satellite dishes • Wall cupboards • Wall mounting for TV and radio • Pipe clamps
Examples of applications
Product information Characteristics • External threaded nylon plug suitable for applications on lightweight concrete blocks (e.g. GASBETON). Benefits • Easy and quick fixings thanks to the external thread • The fixing’s collar prevents it slipping into the drilled hole • Nylon safety and reliability • To be used with chipboard screws, and metrical screws • Possible close to edge applications • Temperature resistant from -40°C to +80°C
Installation • To be mounted aligned the wall Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation • Drill the base material without using roto-percussion
222
universal and frame fixings
Vorpa HZB
Nylon plug for fixings on light weight concrete blocks
Light construction materials
Types of materials where the fixing application is possible
Installation sequence
Technical data
Code
Description
2766 HZB 10/50 2767 HZB 12/60 2768 HZB 14/70
d0 mm
Lt mm
h1 mm
ch mm
Øv metrica mm
Øv legno mm
10 12 14
50 60 70
60 70 80
6 8 10
M6 M8 M10
5,0-6,0 7,0-8,0 9,0-10,0 Lt h1 d0 Tfix Øv ch
= Anchor length = Min. hole depth = Hole diameter = Fixture thickness = Screw diameter = Hexagonal socket
Installation data Oblique axial pull out values in daN Cellular concrete
HZB 10 110
HZB 12 170
ATTENTION: An appropriate safety factor ≥ 3 should be applied on these values.
1 daN ≃1 kg HZB 14 230
As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.
223
universal and frame fixings
Vorpa VP
Hammer-in screw fixing
Concrete
Natural stone
Solid brick
Aerated concrete
Plasterboards
Products group Suitable for • Concrete • Natural stone • Solid brick • Aerated concrete • Plasterboards
VP X with flanged collar
VP TL with large flanged collar
VP INOX with large flanged collar and stainless steel screw
VP ZIP with flanged collar
To fix • Slides • Cable and pipe clamps • Wall connection or plaster profiles • Electrical installations • Plumbing • Door stops • Skirtings • Ducts • Covering installations
Examples of applications
VP NERO with flanged collar
VP RAME with large flanged collar and copper screw
VP RAMATO with copper plated screw, large covering head and large flanged collar
VP G RAME with copper screw, large covering head and large flanged collar
Installation sequence
Product information Characteristics • Hammer-in screw fixing for installations economic series • Various versions available Benefits • Rapid hammerset installation • The integrated hammer-in stop prevents the plug from expanding prematurely • Wide range of diameters, usage lengths and head shapes • Suitable for push-through installation • When hammered in, the nail screw causes the plug to expand in two directions
Installation • Through setting anchors Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation
224
universal and frame fixings
Vorpa VP
Hammer-in screw fixing
Concrete
Natural stone
Solid brick
Aerated concrete
Plasterboards
Technical data VP X with flanged collar Code
620 621 627 622 623 624
Description
VP X 5/30 VP X 6/40 VP X 6/50 VP X 6/60 VP X 8/50 VP X 8/70
dnom x Lt mm
h1 mm
Tfix mm
d0 mm
ØT mm
5 x 30 6 x 40 6 x 50 6 x 60 8 x 50 8 x 70
45 55 65 75 65 85
5 5 15 25 15 25
5 6 6 6 8 8
9 10 10 10 11 11
Pull out values in daN
1 daN ≃1 kg VPX5 90
Concrete C20/25
VPX6 140
VPX8 180
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.
As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.
VP TL with large flanged collar
Code
440 441 425 426 427 1786 1787
Description
dnom x Lt mm
h1 mm
Tfix mm
d0 mm
ØT mm
VP TL 5/25 VP TL 6/30 VP TL 6/40 VP TL 6/50 VP TL 6/60 VP TL 6/80 VP TL 6/100
5 x 25 6 x 30 6 x 40 6 x 50 8 x 60 8 x 80 6 x 100
40 45 55 65 75 95 115
2 2 5 15 25 45 65
5 6 6 6 6 6 6
10 13 14 14 14 14 14
Pull out values in daN
1 daN ≃1 kg VP TL 5 90
Concrete C20/25
VP TL 6 140
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.
As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.
VP INOX with large flanged collar and stainless steel screw
Code
1740 1741 1742 1743
Description
VP INOX VP INOX VP INOX VP INOX
6/30 6/40 6/50 6/60
dnom x Lt mm
h1 mm
Tfix mm
d0 mm
ØT mm
6 x 30 6 x 40 6 x 50 6 x 60
45 55 65 75
2 5 15 25
6 6 6 6
13 14 14 14
Pull out values in daN Concrete C20/25
1 daN ≃1 kg VP INOX 5 90
VP INOX 6 140
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.
VP INOX 8 180
As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.
225
Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness dnom = Plug diameter ØT = Head screw diameter
universal and frame fixings
Vorpa VP
Hammer-in screw fixing
Concrete
Natural stone
Solid brick
Aerated concrete
Plasterboards
Technical data Hammer-in screw fixing VP with large flanged collar. INNOVATIVE DESIGN Code
Description
5740 VP ZIP 5/27 5741 VP ZIP 6/32
dnom x Lt mm
h1 mm
Tfix mm
d0 mm
ØT mm
5 x 27 6 x 32
35 40
3,5 5,0
5 6
11 13
Pull out values in daN
1 daN ≃1 kg VP ZIP 5 70 60 50
Concrete C20/25 Solid brick Hollow brick
VP ZIP 6 90 80 50
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.
As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.
VP NERO with flanged collar Code
1750 1751 1752 1753
Description
VP NERO VP NERO VP NERO VP NERO
6/30 6/40 6/50 6/60
dnom x Lt mm
h1 mm
Tfix mm
d0 mm
ØT mm
6 x 30 6 x 40 6 x 50 6 x 60
45 55 65 75
2 5 15 25
6 6 6 6
13 14 14 14
Pull out values in daN
1 daN ≃1 kg VP NERO 6 140
Concrete C20/25
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.
As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.
VP RAME with large flanged collar and copper screw
Code
1780 1781 1782 1783
Description
VP RAME VP RAME VP RAME VP RAME
6/30 6/40 6/50 6/60
dnom x Lt mm
h1 mm
Tfix mm
d0 mm
ØT mm
6 x 30 6 x 40 6 x 50 6 x 60
45 55 65 75
2 5 15 25
6 6 6 6
13 14 14 14
Pull out values in daN Concrete C20/25
1 daN ≃1 kg VP TL 5 90
VP TL 6 140
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.
As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.
226
Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness dnom = Plug diameter ØT = Head screw diameter
universal and frame fixings
Vorpa VP
Hammer-in screw fixing
Concrete
Natural stone
Solid brick
Aerated concrete
Plasterboards
Technical data VP RAMATO with copper plated screw, large covering head and large flanged collar Code
430R 431R 430 431
Description
VP RAMATO 6/40 VP RAMATO 6/60 VP G RAME 6/40 VP G RAME 6/60
VP G RAME with copper screw, large covering head and large flanged collar
dnom x Lt mm
h1 mm
Tfix mm
d0 mm
ØT mm
6 x 40 6 x 60 6 x 40 6 x 60
55 75 55 75
5 25 5 25
6 6 6 6
14 14 14 14
Pull out values in daN Concrete C20/25
1 daN ≃1 kg VP INOX 5 90
VP INOX 6 140
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.
VP INOX 8 180
As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.
227
Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness dnom = Plug diameter ØT = Head screw diameter
universal and frame fixings
Vorpa VP zamak
Hammer-in zamak preassembled plug
Concrete
Natural stone
Solid brick
Products group To fix • Slides • Cable and pipe clamps • Wall connection or plaster profiles • Electrical installations • Plumbing • Door stops • Skirtings • Ducts • Covering installations
Suitable for • Concrete • Natural stone • Solid brick
Installation sequence
Product information Characteristics • Hammer-in preassembled zamak plug
Installation • Through setting anchors
Benefits • Cost-efficient hammerset installation • Guarantees minimum movement when under load • High safety in use • The ceiling nail is driven into the drill hole with a hammer until it is firmly in position • At the end of the expansion of the pin against the drill hole wall, the hammer-in zamak plug guarantees protection against burglary and thievery
Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation
Technical data
Code
Description
2650 VP ZAMA 6/30 2651 VP ZAMA 6/40 2652 VP ZAMA 6/65
dnom x Lt mm
h1 mm
Tfix mm
d0 mm
6 x 30 6 x 40 6 x 65
40 50 75
5 15 35
6 6 6
Pull out values in daN Concrete C20/25 Solid brick
1 daN ≃1 kg 120 100
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.
As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.
228
Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness dnom = Plug diameter
universal and frame fixings
Vorpa VPO
Hammer-in screw fixing countersunk flanged collar
Concrete
Natural stone
Solid brick
Products group Suitable for • Concrete • Natural stone • Solid brick
VPO hammer-in plug countersunk flanged collar
VPO hammer-in plug countersunk flanged collar stainless steel A2 screw
Examples of applications
To fix • Door frames/windows frames • Counter frames • Wood substructures • Profiles • Skirtings • Electrical installations • Wall connection or plaster profiles • Slides • Sheets • Cable and pipe clamps • Punched tapes • External wood deck
Examples of applications
Installation sequence
Product information Characteristics • Integrated hammer-in nylon plug for push-through installation
Installation • Through setting anchors
Benefits • Easy fast and economical fixing • Suitable for substructures made of wood and metal • Ideal for an economic series installation • The hammer in plug structure prevents the plug from expanding prematurely • The thread of the nail screw allows the screw to be removed • When hammered in, the nail screw causes the plug to expand in two directions
Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation
229
universal and frame fixings
Vorpa VPO
Hammer-in screw fixing countersunk flanged collar
Concrete
Natural stone
Solid brick
Technical data VPO hammer-in plug countersunk flanged collar
Code
690 662 1663 663 691 1664 664 692 693 694 698 668 699 2950 2951 2952
Description
dnom x Lt mm
h1 mm
Tfix mm
d0 mm
VP O VP O VP O VP O VP O VP O VP O VP O VP O VP O VP O VP O VP O VP O VP O VP O
5 x 35 5 x 50 6 x 40 6 x 50 6 x 60 6 x 70 6 x 80 8 x 60 8 x 80 8 x 100 8 x 120 8 x 135 10 x 100 10 x 120 10 x 140 10 x 160
45 60 50 60 70 80 90 70 90 110 130 145 110 130 150 170
5 20 10 20 30 40 50 20 40 60 80 95 60 70 90 100
5 5 6 6 6 6 6 8 8 8 8 8 10 10 10 10
5/35 5/50 6/40 6/50 6/60 6/70 6/80 8/60 8/80 8/100 8/120 8/135 10/100 10/120 10/140 10/160
Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Hole diameter in the fixture dnom = Plug diameter
VPO hammer-in plug countersunk flanged collar stainless steel A2 screw Code
3643 3644 3645 3646 3647 3648
Description
VP O VP O VP O VP O VP O VP O
A2 A2 A2 A2 A2 A2
6/40 6/60 6/80 8/60 8/80 8/100
dnom x Lt mm
h1 mm
Tfix mm
d0 mm
6 x 40 6 x 60 6 x 80 8 x 60 8 x 80 8 x 100
55 75 95 75 95 115
10 30 50 20 40 60
6 6 6 8 8 8
Pull out values in daN Concrete C20/25 Solid brick
1 daN ≃1 kg VP 5 90 80
VP 6 140 110
VP 8 180 150
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.
VP 10 310 280
As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.
230
Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Hole diameter in the fixture dnom = Plug diameter
universal and frame fixings
Vorpa VPI
Hammer-in screw fixing flanged collar
Concrete
Natural stone
Solid brick
Products group Suitable for • Concrete • Natural stone • Solid brick
VPI hammer-in plug flanged collar
Examples of applications
To fix • Door frames/windows frames • Counter frames • Wood substructures • Profiles • Skirtings • Electrical installations • Wall connection or plaster profiles • Slides • Sheets • Cable and pipe clamps • Punched tapes
Examples of applications
Installation sequence
Product information Characteristics • Integrated hammer-in nylon plug for push-through installation
Installation • Through setting anchors
Benefits • Easy fast and economical fixing • Suitable for substructures made of wood and metal • Ideal for an economic series installation • The hammer in plug structure prevents the plug from expanding prematurely • The thread of the nail screw allows the screw to be removed • When hammered in, the nail screw causes the plug to expand in two directions
Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation
231
universal and frame fixings
Vorpa VPI
Hammer-in screw fixing flanged collar
Concrete
Natural stone
Solid brick
Technical data
VPI hammer-in plug flanged collar
Code
Description
dnom x Lt mm
h1 mm
Tfix mm
d0 mm
2689 2690N 2626 2663 2691N 2664 2665 2692 2693 2628 2694 2698 2699N
VP I 5/25 VP I 5/30 VP I 5/50 VP I 6/50 VP I 6/60 VP I 6/80 VP I 8/50 VP I 8/60 VP I 8/70 VP I 8/80 VP I 8/100 VP I 8/120 VP I 8/140
5 x 25 5 x 30 5 x 50 6 x 50 6 x 60 6 x 80 8 x 50 8 x 60 8 x 70 8 x 80 8 x 100 8 x 120 8 x 140
35 40 60 60 70 90 60 70 80 90 110 130 150
3 5 20 20 30 50 10 20 30 40 60 80 100
5 5 5 6 6 6 8 8 8 8 8 8 8
Pull out values in daN Concrete C20/25 Solid brick
1 daN ≃1 kg VP 5 90 80
VP 6 140 110
VP 8 180 150
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.
VP 10 310 280
As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.
232
Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Hole diameter in the fixture dnom = Plug diameter
universal and frame fixings
Vorpa VP I CE
Hammer-in screw fixing with European Technical Approval
Concrete
Natural stone
Solid brick
Products group
VP I CE hammer-in plug
ETAG 014
Approved for • Non-cracked concrete for fixing of external thermal insulation composite system use cat. A Also suitable for • Natural stone • Solid brick
To fix • Door frames/windows frames • Counter frames • Wood substructures - profiles • External the thermal insulation profiles • Skirtings insulation profiles
Use categories A As it can also be used on concrete with different strength characteristics, as specified in ETA, on compact natural stone and others materials (exception not included in ETA), specific on-site tests by the user are necessary
Examples of applications
Installation sequence
Product information Installation Characteristics • Through setting anchors • Integrated hammer-in nylon plug for push-through installation • Nailed-in plastic anchors for fixing of External thermal insulation Suggestion for use composite system with rendering in concrete ETAG 014 • Always consider an appropriate safety factor • Check load bearing capacity values Benefits • Respect the installation data • Easy fast and economical fixing • Clean the hole before the installation • Suitable for substructures made of wood and metal • Ideal for an economic series installation • The hammer in plug structure prevents the plug from expanding prematurely • The thread of the nail screw allows the screw to be removed • When hammered in, the nail screw causes the plug to expand in two directions
233
universal and frame fixings
Vorpa VP I CE Hammer-in screw fixing
Concrete
Natural stone
Solid brick
Technical data
VP I CE hammer-in plug
Code
4154 4155 4156 4157 4158 4159 4160 4161 4162
Description
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
d0 mm
hef mm
VP I CE VP I CE VP I CE VP I CE VP I CE VP I CE VP I CE VP I CE VP I CE
6 x 40 6 x 50 6 x 60 6 x 80 8 x 60 8 x 80 8 x 100 8 x 120 8 x 140
4 x 45 4 x 65 4 x 85 5 x 50 5 x 65 5 x 85 5 x 105 5 x 125 5 x 145
50 60 70 90 70 90 110 130 150
10 20 30 50 20 40 60 80 100
6 6 6 6 8 8 8 8 8
30 30 30 30 40 40 40 40 40
6/40 6/50 6/60 6/80 8/60 8/80 8/100 8/120 8/140
Installation data
Non-cracked concrete Use category A Installation data Minimum spacing Minimum edge distance Minimum thicknes of the member
Smin Cmin hmin
1 kN ≃100 kg mm 100 mm 100 mm 100
Characteristic values NON-CRACKED CONCRETE Pull out failure Nrk,P C12/15 Nrk,P C20/25-C50/60 Values where the reduction factor γ is included (Design loads) Pull out failure Nrk,P C12/15 Nrk,P C20/25-C50/60 Recommended loads Pull out failure C12/15 C20/25-C50/60 application on solid brick: not covered by ETA Characteristic values SOLID BRICK Pull out failure **solid brick
N N
KN KN
KN KN
KN KN
KN
VP I CE 6
VP I CE 8
0,50 0,75
0,40 0,60
VP I CE 6
VP I CE 8
0,25 0,38
0,20 0,30
VP I CE 6
VP I CE 8
0,16 0,24
0,13 0,20
VP I CE 6
VP I CE 8
0,30
0,20
ATTENTION: An appropriate safety factor ≥ 3 should be applied on these values on solid brick.
234
Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Hole diameter in the fixture dnom = Plug diameter hef = Embedment depth
universal and frame fixings
Vorpa VP C CE
Multi-purpose nylon fixing with European Technical Assesment
Concrete
Solid brick
Perforated brick
Hollow brick
Vulcanic Tuf
Poroton
Products group Approved for • Cracked and non-cracked concrete C12/15 - C50/60 use cat. A-B-C-D ETAG 020
VP C TSP
Also suitable for • Solid brick • Perforated brick • Hollow brick • Vulcanic tuf • Aerated concrete
VP C TE VP C TE A4
To fix • Window and door frames • Light structural works • Wooden substructures • Handrail
R90 only Ø10
VP C TC
ETAG 020 Use cat. A-B-C-D
Examples of applications
Product information Characteristics • Extra long nylon fixing with countersunk or cylinder edge suitable for applications on compact and hollow materials. Supplied with different types of screws Benefits • Safe and quick fixings • Special anti-rotation wings that prevents the plug turning in the hole on installation • The plug’s neck avoid the introduction of the plug inside the hole • Resistant to temperatures from -40°C to +80°C • European Technical Approval ETAG 020 • Special wings to avoid turning The special anti-rotation wings on the nylon sleeve provides easy and safe installation on all types of material, avoiding any rotation of the nylon sleeve while the screw is installed • No waiting time before loading • Ideal for fixing of facade, frames and general fastenings
Benefits • Fully radial expansion behaviour on concrete and solid masonry • Multiple radial expansion behaviour on perforated masonry • Knotting behaviour on hollow masonry • Temperature resistant from -40°C to + 80°C • Fire resistant only Ø10 R90 Installation • Through setting anchors Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation
235
universal and frame fixings
Vorpa VP C CE Multi-purpose nylon fixing
Concrete
Solid brick
Perforated brick
Hollow brick
Vulcanic Tuf
Poroton
Installation sequence On compact materials
Make a drill hole with a hammer drill
Clean the hole
Place the fixture and then insert the anchor into the hole
Put the anchor by hammering softly on the screw head until the fixture stops the nylon plug
Make sure that the fixture is supported by the anchor (nylon plug and screw)
Clean the hole
Place the fixture and the anchor into the hole by hand
Put the anchor by hammering softly on the screw head until the fixture stops the nylon plug
Sent the screw by screw driver or by hand. Make sure that the fixture is supported by the anchor (nylon plug and screw)
On hollow materials
Make a drill hole just by rotary drilling
Technical data
Nylon plug VP C with Torx recess flat countersunk head screw
Code Code Zincplated St. Steel
6100 6101 6102 6103 6104 * 6105 * 6106 * 6107 * 6108 * 6109 * 6110 *
6196 6197 6198 6199 6200 * 6201 * 6202 * 6203 * 6204 * 6205 * 6206 *
Description
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
d0 mm
hef mm
df mm
T
VP C 8/80 TSP VP C 8/100 TSP VP C 8/120 TSP VP C 8/140 TSP VP C 10/80 TSP VP C 10/100 TSP VP C 10/120 TSP VP C 10/140 TSP VP C 10/160 TSP VP C 10/200 TSP VP C 10/230 TSP
8x80 8x100 8x120 8x140 10x80 10x100 10x120 10x140 10x160 10x200 10x230
6x85 6x105 6x125 6x145 7x85 7x105 7x125 7x145 7x165 7x205 7x235
90 90 90 90 90 90 90 90 90 90 90
10 30 50 70 10 30 50 70 90 130 160
8 8 8 8 10 10 10 10 10 10 10
70 70 70 70 70 70 70 70 70 70 70
9 9 9 9 11 11 11 11 11 11 11
TX30 TX30 TX30 TX30 TX40 TX40 TX40 TX40 TX40 TX40 TX40
*VS-Handyplug Ø10: at least 90 minutes fire resistance (R90) for fastening of façade systems on concrete, if the admissible load ≤0,8 [kN] (no permanent centric tension load).
236
Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Diameter of clearance hole in the fixture dnom = Plug diameter hef = Embedment depth
universal and frame fixings
Vorpa VP C CE Multi-purpose nylon fixing
Concrete
Solid brick
Perforated brick
Hollow brick
Vulcanic Tuf
Poroton
Technical data
Nylon plug VP C with Torx recess hexagonal washer head special wood screw
Code Code Zincplated St. Steel
6112 6113 6114 6115 6116 * 6117 * 6118 * 6119 * 6120 * 6121 * 6122 *
6184 6185 6186 6187 6188 * 6189 * 6190 * 6191 * 6192 * 6193 * 6194 *
Description
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
d0 mm
hef mm
df mm
Ch
T
VP C 8/80 TE VP C 8/100 TE VP C 8/120 TE VP C 8/140 TE VP C 10/80 TE VP C 10/100 TE VP C 10/120 TE VP C 10/140 TE VP C 10/160 TE VP C 10/200 TE VP C 10/230 TE
8x80 8x100 8x120 8x140 10x80 10x100 10x120 10x140 10x160 10x200 10x230
6x85 6x105 6x125 6x145 7x85 7x105 7x125 7x145 7x165 7x205 7x235
90 90 90 90 90 90 90 90 90 90 90
10 30 50 70 10 30 50 70 90 130 160
8 8 8 8 10 10 10 10 10 10 10
70 70 70 70 70 70 70 70 70 70 70
9 9 9 9 11 11 11 11 11 11 11
10 10 10 10 13 13 13 13 13 13 13
TX30 TX30 TX30 TX30 TX40 TX40 TX40 TX40 TX40 TX40 TX40 Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Diameter of clearance hole in the fixture dnom = Plug diameter hef = Embedment depth
Nylon plug VP C with Torx recess mushroom head special wood screw
Code
6124 6125 6126 6127 6128 6129 * 6130 * 6131 * 6132 * 6133 *
Description
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
d0 mm
hef mm
T
VP C 8/80 TC VP C 8/100 TC VP C 8/120 TC VP C 8/140 TC VP C 10/80 TC VP C 10/100 TC VP C 10/120 TC VP C 10/140 TC VP C 10/160 TC VP C 10/200 TC
8x80 8x100 8x120 8x140 10x80 10x100 10x120 10x140 10x160 10x200
6x85 6x105 6x125 6x145 7x85 7x105 7x125 7x145 7x165 7x205
90 90 90 90 90 90 90 90 90 90
10 30 50 70 10 30 50 70 90 130
8 8 8 8 10 10 10 10 10 10
70 70 70 70 70 70 70 70 70 70
TX30 TX30 TX30 TX30 TX40 TX40 TX40 TX40 TX40 TX40
*VS-Handyplug Ø10: at least 90 minutes fire resistance (R90) for fastening of façade systems on concrete, if the admissible load ≤0,8 [kN] (no permanent centric tension load).
237
Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Diameter of clearance hole in the fixture dnom = Plug diameter hef = Embedment depth
universal and frame fixings
Vorpa VP C CE Multi-purpose nylon fixing
Concrete
Solid brick
Perforated brick
Cracked and non-cracked concrete (C16/20) Installation data Minimum spacing Smin Minimum edge distance Cmin Minimum thicknes of the member hmin
mm mm mm
VP C Ø8 90 90 140
VP C Ø10 100 100 140
Pull out characteristic values VP C Temperature range Characteristic resistance
°C kN
VP C Ø8 24-40 50-80 3.5 3.0
VP C Ø10 24-40 50-80 4.5 4.0
T NRK,p
Use category A
Installation data
Solid masonry 110x60x240 “Danesi” (density 1,7 Kg/dm3 - min. compression strenght 39 N/mm2) Installation data VP C Ø8 VP C Ø10 Single anchor Minimum edge distance Cmin mm 120 120 Group of anchors Minimum edge distance Cmin mm 120 120 Minimum spacing S1min mm 240 240 (perpendicular to free edge) Minimum spacing S2min mm 480 480 (parallel to free edge) Minimum thicknes of the member hmin mm 110 110
NRK,p
kN
VP C Ø8 3.0
VP C Ø10 2.0
Solid masonry 250x120x55 “Terreal Italia” (density 1,7 Kg/dm3 - min. compression strenght 27 N/mm2) Installation data VP C Ø8 VP C Ø10 Single anchor Minimum edge distance mm 120 120 Cmin Group of anchors Minimum edge distance mm 125 125 Cmin Minimum spacing mm 250 250 S1min (perpendicular to free edge) Minimum spacing mm 500 500 S2min (parallel to free edge) Minimum thicknes of the member hmin mm 120 120 Pull out characteristic values VP C Characteristic resistance
NRK,p
kN
VP C Ø8 4.0
VP C Ø10 5.0
Solid masonry fine tuff 370x370x110 “Cave riunite” (density 2,4 Kg/dm3 - min. compression strenght 7,5 N/mm2) Installation data VP C Ø8 VP C Ø10 Single anchor Minimum edge distance mm 185 185 Cmin Group of anchors Minimum edge distance mm 185 185 Cmin Minimum spacing mm 370 370 S1min (perpendicular to free edge) Minimum spacing mm 740 740 S2min (parallel to free edge) Minimum thicknes of the member hmin mm 370 370 Pull out characteristic values VP C Characteristic resistance
NRK,p
kN
VP C Ø8 -
VP C Ø10 0.3
Calcium silicate solid brick KS-R(P)-202.0 - 8DF (240) “Heidelberg - Kalksandstein” (density 1.9 Kg/dm3 - min. compression strenght 28.2 N/mm2) Installation data VP C Ø8 VP C Ø10 Single anchor Minimum edge distance mm 120 120 Cmin Group of anchors Minimum edge distance mm 240 240 Cmin Minimum spacing mm S1min (perpendicular to free edge) 480 480 Minimum spacing mm S2min (parallel to free edge) 120 120 Minimum thicknes of the member hmin mm 240 240 Pull out characteristic values VP C Characteristic resistance
NRK,p
kN
VP C Ø8 5.5
VP C Ø10 6.0
238
Use category B
Pull out characteristic values VP C Characteristic resistance
Hollow brick
Vulcanic Tuf
Poroton
universal and frame fixings
Vorpa VP C CE Multi-purpose nylon fixing
Concrete
Solid brick
Perforated brick
Installation data
Solid masonry doppio UNI 120x245x250 “Danesi” (density 0.9 Kg/dm3 min. compression strenght 13 N/mm2))
Installation data Single anchor Minimum edge distance Group of anchors Minimum edge distance Minimum spacing (perpendicular to free edge) Minimum spacing (parallel to free edge) Minimum thicknes of the member
VP C Ø10
Cmin
mm
125
125
Cmin S1min
mm mm
125 250
125 250
S2min
mm
500
500
hmin
mm
120
120
NRK,p
kN
VP C Ø8 -
VP C Ø10 0.3
Use category C
Pull out characteristic values VP C Characteristic resistance
VP C Ø8
Hollow brick 120x250x250 “Wienerberger” (density 0.6 Kg/dm3 min. compression strenght 2,0 N/mm2)
Installation data Single anchor Minimum edge distance Group of anchors Minimum edge distance Minimum spacing (perpendicular to free edge) Minimum spacing (parallel to free edge) Minimum thicknes of the member Pull out characteristic values VP C Characteristic resistance
VP C Ø8
VP C Ø10
Cmin
mm
125
125
Cmin S1min
mm mm
75 250
75 250
S2min
mm
500
500
hmin
mm
120
120
NRK,p
kN
VP C Ø8 0.3
VP C Ø10 -
239
Hollow brick
Vulcanic Tuf
Poroton
universal and frame fixings
Vorpa VP C CE Multi-purpose nylon fixing
Concrete
Solid brick
Perforated brick
Installation data
500 10 15 35
235
5
Poroton T-24,0-0,9 “Wieneberger” (density 0.9 Kg/dm3 min. compression strenght 7.0 N/mm2)
15
235
110
Installation data 235 Single anchor 15 Minimum edge distance Group of anchors 10 Minimum spacing 25 (perpendicular to free edge) 500 Minimum spacing 10 10 15 edge) (parallel to free 18 Minimum edge 35 distance Minimum thicknes of the member 5 Pull out characteristic values VP C Characteristic resistance 15
VP C Ø8
VP C Ø10
Cmin
mm
120
120
S1min
mm
240
240
S2min
mm
480
480
Cmin hmin
mm mm
120 240
120 240
NRK,p
kN
VP C Ø8 0.9
VP C Ø10 0.9
240 30
25
Use category C
175
35 10 235
21
15
25 10
28
38
110
25 10
Poroton HIZB - ZDF - 0.9 “Wieneberger” (density 0.9 Kg/dm3 min. compression strenght 16.4 N/mm2)
18
175
Installation data Single anchor Minimum edge distance 240 Cmin Anchor Group 30 25 Minimum spacing 35 S1min (perpendicular to free edge) 10 21 Minimum spacing S2min 25 (parallel to free edge) 28 Minimum edge distance Cmin38 Minimum thicknes of the member hmin Pull out characteristic values VP C Characteristic resistance
NRK,p
VP C Ø8
VP C Ø10
mm
120
120
mm
240
240
mm
480
480
mm mm
120 115
120 115
kN
VP C Ø8 0.9
VP C Ø10 0:9
240
Hollow brick
Vulcanic Tuf
Poroton
235
universal and frame fixings 15
Vorpa VP C CE 10
Multi-purpose nylon fixing
Concrete
10
18
Solid brick
Perforated brick
Installation data
240 30
25
21
10 25 28
Hollow calcium silicate brick “Heidelberger - Kalksanstein” (density 1.5 Kg/dm3 min. compression strenght 16.3 N/mm2)
38
Installation data Single anchor Minimum edge distance Group of anchors Minimum spacing (perpendicular to free edge) Minimum spacing (parallel to free edge) Minimum edge distance Minimum thicknes of the member Pull out characteristic values VP C Characteristic resistance
VP C Ø8
VP C Ø10
Cmin
mm
120
120
S1min
mm
240
240
S2min
mm
480
480
Cmin hmin
mm mm
120 175
120 175
NRK,p
kN
VP C Ø8 5.0
VP C Ø8 5.5
Use category C
175
35
Autoclaved aerated concrete (density 0.5 Kg/dm3 min. compression strenght 3.5 N/mm2)
Installation data Single anchor Minimum edge distance Group of anchors Minimum spacing (perpendicular to free edge) Minimum spacing (parallel to free edge) Minimum edge distance Minimum thicknes of the member Pull out characteristic values VP C Characteristic resistance
VP C Ø8
VP C Ø10
Cmin
mm
240
240
S1min
mm
120
120
S2min
mm
240
240
Cmin hmin
mm mm
480 120
480 120
NRK,p
kN
VP C Ø8 0.5
VP C Ø8 0.6
Use categories a b
Subcategories
c
C hollow brick UNI 13 N/mm2 D hollow brick 2 N/mm2 G Poroton 7 N/mm2 H Poroton 16.4 N/mm2 I Hollow calcium silicate brick 16.3 N/mm2
Substrates Concrete C12/15 - C50/60
A solid brick 39 N/mm2 B solid brick 27 N/mm2 E fine tuff 7,5 N/mm
Autoclaved aerated concrete
241
Use category D
110
25
Hollow brick
Vulcanic Tuf
Poroton
universal and frame fixings
Vorpa VP R6
Nylon frame fixings with multiple wings
Concrete
Solid brick
Hollow brick
Products group
VP R6 Nylon frame fixing
Suitable for • Concrete • Solid brick • Hollow brick • Natural stone
To fix • Light carpentry • Wood coatings • Handrails • Wood substructures • Door frames • Window frames • Counter frames
VP R6 E Nylon frame with chipboard screw Examples of applications
VP R6 ET Nylon frame fixing with Torx recess chipboard screw
VP R6 IA2 nylon frame fixing with stainless steel chipboard screw
VP R6 Z nylon frame fixing with hexagonal bolt screw
VP R6 VS nylon frame fixing with safety Torx recess screw
Product information Characteristics • Nylon frame fixing with multiple wings
Installation • Through setting anchors
Benefits • Suitable for use in all solid and hollow building materials • Guarantees a simple installation • Wide range of applications • Suitable for push-through installation • Plug with special anti-rotation wings • The higher lenght allows the anchor to contain the entire thickness of the element to be fastened
Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation
242
Natural stone
universal and frame fixings
Vorpa VP R6
Nylon frame fixings with multiple wings
Concrete
Solid brick
Hollow brick
Natural stone
Installation sequence On compact materials
Make a drill hole with a hammer drill
Clean the hole
Place the fixture and then insert the anchor into the hole
Put the anchor by hammering softly on the screw head until the fixture stops the nylon plug
Make sure that the fixture is supported by the anchor (nylon plug and screw)
Clean the hole
Place the fixture and the anchor into the hole by hand
Put the anchor by hammering softly on the screw head until the fixture stops the nylon plug
Sent the screw by screw driver or by hand. Make sure that the fixture is supported by the anchor (nylon plug and screw)
On hollow materials
Make a drill hole just by rotary drilling
Product information
Technical data VP R6 Nylon frame fixing
Code
565 520 1564 566 568 569 570 567 1568
Description
d0 mm
h1 mm
Lt mm
Tfix mm
hef mm
df mm
screws mm
VP R6 VP R6 VP R6 VP R6 VP R6 VP R6 VP R6 VP R6 VP R6
8 8 8 10 10 10 10 10 10
90 110 130 90 110 125 145 170 210
80 100 120 80 100 115 135 160 200
10 30 50 10 30 45 65 90 130
70 70 70 70 70 70 70 70 70
8 8 8 10 10 10 10 10 10
5,5 5,5 5,5 7 7 7 7 7 7
8/80 8/100 8/120 10/80 10/100 10/115 10/135 10/160 10/200
243
Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Ă&#x2DC;v = Screw diameter Lv = Screw length df = Hole diameter in the fixture dnom = Plug diameter hef = Effective embedment depth ch = Spanner
universal and frame fixings
Vorpa VP R6
Nylon frame fixings with multiple wings
Concrete
Solid brick
Hollow brick
Natural stone
Technical data
VP R6 nylon frame with chipboard screw
Code
1283 289 1284 1285 285 286 287 288 303
Description
VP R6 E VP R6 E VP R6 E VP R6 E VP R6 E VP R6 E VP R6 E VP R6 E VP R6 E
8/80 8/100 8/120 10/80 10/100 10/115 10/135 10/160 10/200
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
d0 mm
hef mm
df mm
8x80 8x100 8x120 10x80 10x100 10x115 10x135 10x160 10x200
5,5x85 5,5x105 5,5x125 7x85 7x105 7x120 7x140 7x165 7x205
90 110 130 90 110 125 145 170 210
10 30 50 10 30 45 65 90 130
8 8 8 10 10 10 10 10 10
70 70 70 70 70 70 70 70 70
8 8 8 10 10 10 10 10 10
VP R6 E nylon frame fixing with Torx recess chipboard screw
Code
1287 1288 1289 1290 1291 1292 1293 1294 1295
Description
VP R6 ET VP R6 ET VP R6 ET VP R6 ET VP R6 ET VP R6 ET VP R6 ET VP R6 ET VP R6 ET
8/80 8/100 8/120 10/80 10/100 10/115 10/135 10/160 10/200
TX30 TX30 TX30 TX40 TX40 TX40 TX40 TX40 TX40
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
d0 mm
hef mm
df mm
8x80 8x100 8x120 10x80 10x100 10x115 10x135 10x160 10x200
5,5x85 5,5x105 5,5x125 7x85 7x105 7x120 7x140 7x165 7x205
90 110 130 90 110 125 145 170 210
10 30 50 10 30 45 65 90 130
8 8 8 10 10 10 10 10 10
70 70 70 70 70 70 70 70 70
8 8 8 10 10 10 10 10 10
VP R6 IA2 nylon frame fixing with stainless steel chipboard screw
Code
Description
10000 10001 10002 10003 10004 10005 10006 10007
VP R6 I A2 VP R6 I A2 VP R6 I A2 VP R6 I A2 VP R6 I A2 VP R6 I A2 VP R6 I A2 VP R6 I A2
8/80 TX30 8/100 TX30 8/120 TX30 10/80 TX40 10/100 TX40 10/115 TX40 10/135 TX40 10/160 TX40
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
d0 mm
hef mm
df mm
8x80 8x100 8x120 10x80 10x100 10x115 10x135 10x160
5,5x85 5,5x105 5,5x125 7x85 7x105 7x120 7x140 7x165
90 110 130 90 110 125 145 170
10 30 50 10 30 45 65 90
8 8 8 10 10 10 10 10
70 70 70 70 70 70 70 70
8 8 8 10 10 10 10 10
244
Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Hole diameter in the fixture dnom = Plug diameter hef = Effective embedment depth
universal and frame fixings
Vorpa VP R6
Nylon frame fixings with multiple wings
Concrete
Solid brick
Hollow brick
Natural stone
Technical data
VP R6 Z nylon frame fixing with hexagonal bolt screw
Code
1372 1373 1374 1375 378 379 1380 1381 1386
Description
VP R6 Z VP R6 Z VP R6 Z VP R6 Z VP R6 Z VPR6 Z VPR6 Z VPR6 Z VPR6 Z
8/80 8/100 8/120 10/80 10/100 10/115 10/135 10/160 10/200
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
d0 mm
hef mm
df mm
Ch mm
8x80 8x100 8x120 10x80 10x100 10x115 10x135 10x160 10x200
5,5x85 5,5x105 5,5x125 7x90 7x105 7x120 7x140 7x165 7x205
90 110 130 90 110 125 145 170 210
10 30 50 10 30 45 65 90 130
8 8 8 10 10 10 10 10 10
70 70 70 70 70 70 70 70 70
8 8 8 10 10 10 10 10 10
10 10 10 13 13 13 13 13 13
VP R6 VSnylon frame fixing with safety Torx recess screw
Code
1390 1391 1392 1393 1994 1995
Description
VP R6 VS 10/90 VP R6 VS 10/100 VP R6 VS 10/115 VP R6 VS 10/135 VP R6 VS 10/160 VP R6 VS 10/200
TX40 TX40 TX40 TX40 TX40 TX40
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
d0 mm
hef mm
df mm
10x80 10x100 10x115 10x135 10x160 10x200
7x90 7x105 7x120 7x140 7x165 7x205
105 115 125 145 170 210
10 30 45 65 90 130
10 10 10 10 10 10
70 70 70 70 70 70
10 10 10 10 10 10
Installation data Pull out values in daN Concrete C20/25 Solid brick Double brick UNI with plaster
1 daN ≃1 kg VP R6 Ø mm 8 380 300 120
VP R6 Ø mm 10 480 380 150
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.
As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.
245
Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Hole diameter in the fixture dnom = Plug diameter hef = Effective embedment depth ch = Spanner
universal and frame fixings
Vorpa VP R8
Nylon fixings with multiple wings for frame and light carpentry
Concrete
Solid brick
Hollow brick
Natural stone
Products group Suitable for • Concrete • Solid brick • Hollow brick • Natural stone
VP R8 nylon plug
Examples of applications
To fix • Light carpentry • Wood coatings • Handrails • Wood substructures • Door frames • Window frames • Counter frames
VP R8 TE nylon plug with hexagonal bolt screw
VP R8 TSP nylon plug with chipboard screw
Installation sequence On compact materials
Make a drill hole with a hammer drill
Clean the hole
Place the fixture and then insert the anchor into the hole
Put the anchor by hammering softly on the screw head until the fixture stops the nylon plug
Make sure that the fixture is supported by the anchor (nylon plug and screw)
Clean the hole
Place the fixture and the anchor into the hole by hand
Put the anchor by hammering softly on the screw head until the fixture stops the nylon plug
Sent the screw by screw driver or by hand. Make sure that the fixture is supported by the anchor (nylon plug and screw)
On hollow materials
Make a drill hole just by rotary drilling
Product information Characteristics • Nylon plug for frames and light carpentry
Installation • Through setting anchors
Benefits • Guarantees a simple installation • Wide range of applications • Suitable for push-through installation • Plug with special anti-rotation wings • The higher lenght allows the anchor to contain the entire thickness of the element to be fastened
Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation
246
universal and frame fixings
Vorpa VP R8
Nylon fixings with multiple wings for frame and light carpentry
Concrete
Solid brick
Hollow brick
Natural stone
Technical data VP R8 nylon plug
Code
Description
d0 mm
h1 mm
Lt mm
Tfix mm
hef mm
df mm
screws mm
51386 51387 1571 1572 830S 586 51384 51385 51389
VP R8 VP R8 VP R8 VP R8 VP R8 VP R8 VP R8 VP R8 VP R8
10 10 12 12 16 16 16 16 16
255 295 215 255 155 175 215 255 320
240 280 200 240 140 160 200 240 300
140 180 100 140 40 60 100 140 200
100 100 100 100 100 100 100 100 100
11 11 13 13 17 17 17 17 17
7 7 10 10 12 12 12 12 12
10/240 10/280 12/200 12/240 16/140 16/160 16/200 16/240 16/300
VP R8 TE nylon plug with hexagonal bolt screw
Code
Description
52395 52396 1387 1388 1382 1383 1384 1385 52397
VP R8 TE VP R8 TE VP R8 TE VP R8 TE VP R8 TE VP R8 TE VP R8 TE VP R8 TE VP R8 TE
10/240 10/280 12/200 12/240 16/140 16/160 16/200 16/240 16/300
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
hef mm
d0 mm
df mm
Ch mm
10x240 10x280 12x200 12x240 16x140 16x160 16x200 16x240 16x300
7x245 7x285 10x200 10x240 12x140 12x160 12x200 12x240 12x300
255 295 215 255 155 175 215 255 320
140 180 100 140 40 60 100 140 200
100 100 100 100 100 100 100 100 100
10 10 12 12 16 16 16 16 16
11 11 13 13 17 17 17 17 17
13 13 17 17 19 19 19 19 19
VP R8 TSP nylon plug with chipboard screw
Description
dnom x Lt mm
Øv x Lv mm
h1 mm
hef mm
Tfix mm
d0 mm
df mm
51395 VP R8 TSP 10/240 51396 VP R8 TSP 10/280
10x240 10x280
7x245 7x285
255 295
100 100
140 180
10 10
11 11
Code
Installation data Pull out values in daN Concrete C20/25 Solid brick Double brick UNI with plaster
1 daN ≃1 kg VP R8 Ø10 480 380 300
VP R8 Ø12 680 400 300
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.
VP R8 Ø16 820 480
As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.
247
Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Hole diameter in the fixture dnom = Plug diameter hef = Effective anchorage depth ch = Spanner
universal and frame fixings
Vorpa VP A
Nylon frame fixings with multiple wings
Concrete
Solid brick
Natural stone
Products group VP A nylon frame plug with chipboards screw
Suitable for • Concrete • Solid brick • Natural stone
VP A nylon frame plug with A2 stainless steel screw Torx recess
To fix • Light carpentry • Wood coatings • Handrails • Wood substructures • Door frames • Window frames • Counter frames
Examples of applications
Installation sequence
Make a drill hole with a hammer drill
Clean the hole
Place the fixture and then insert the anchor into the hole
Put the anchor by hammering softly on the screw head until the fixture stops the nylon plug
Make sure that the fixture is supported by the anchor (nylon plug and screw)
Product information Characteristics • Nylon frame plug with wings for light carpentry and substructures fixings Benefits • The expanding portion has a limited length, the use is suggested mainly with solid materials • Guarantees a simple installation • Wide range of applications • Suitable for push-through installation • Plug with special anti-rotation wings • The higher lenght allows the anchor to contain the entire thickness of the element to be fastened
Installation • Through setting anchors Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation
248
universal and frame fixings
Vorpa VP A
Nylon frame fixings with multiple wings
Concrete
Solid brick
Natural stone
Technical data
VP A nylon frame plug with chipboards screw
Code
304 348 305 349 323 306 307 308 309 310
Description
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
d0 mm
hef mm
df mm
VP A 6/60 VP A 8/60 VP A 8/80 VP A 8/100 VP A 8/120 VP A 10/80 VP A 10/100 VP A 10/115 VP A 10/135 VP A 10/160
6x60 8x60 8x80 8x100 8x120 10x80 10x100 10x115 10x135 10x160
4x65 5,5x65 5,5x85 5,5x105 5,5x125 7x85 7x105 7x120 7x140 7x165
70 70 90 110 130 95 115 130 150 175
30 20 40 60 80 30 50 65 85 110
6 8 8 8 8 10 10 10 10 10
30 40 40 40 40 50 50 50 50 50
7 9 9 9 9 11 11 11 11 11
VP A nylon frame plug with A2 stainless steel screw Torx recess
Code
4140 4141 4142 4143 4144 4145 4146 4147 4148
Description
dnom x Lt mm
Øv x Lv mm
h1 mm
Tfix mm
d0 mm
hef mm
df mm
VP A A2 VP A A2 VP A A2 VP A A2 VP A A2 VP A A2 VP A A2 VP A A2 VP A A2
8x60 8x80 8x100 8x120 10x80 10x100 10x115 10x135 10x160
5,5x65 5,5x85 5,5x105 5,5x125 7x85 7x105 7x120 7x140 7x165
70 90 110 130 95 115 130 150 175
20 40 60 80 30 50 65 85 110
8 8 8 8 10 10 10 10 10
40 40 40 40 50 50 50 50 50
9 9 9 9 11 11 11 11 11
8/60 TX30 8/80 TX30 8/100 TX30 8/120 TX30 10/80 TX40 10/100 TX40 10/115 TX40 10/135 TX40 10/160 TX40
Installation data Pull out values in daN Concrete C20/25 Solid brick
1 daN ≃1 kg VP A Ø6 200 150
VP A Ø8 340 300
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.
VP A Ø10 420 350
As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.
249
Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Hole diameter in the fixture dnom = Plug diameter hef = Effective embedment depth ch = Spanner
universal and frame fixings
Vorpa FSS-FSC
Through steel screw for windows frame
Concrete
Solid brick
Hollow brick
Aerated concrete
Products group To fix • Door frames • Window frames
Suitable for • Concrete • Solid brick • Hollow brick • Aerated concrete
FSS flat-head
FSC cylinder-head
Product information Characteristics • Special threaded steel screws Torx recess for window frames Benefits • Quick, easy, economical • Efficient work • No additional plugs are required for screw installation • The continuous thread prevents the window frame from being pulled against the substrate • Stress-free and long-lasting fixing of frame • The special thread reduces the amount of force required for screwing in the screws Installation sequence
Benefits • Cylinder-head screws are recommended for recessed installation in wooden profiles • Flat-head screws are recommended for installation in plastic and alluminium profiles Installation • To be mounted aligned the wall Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation Solid brick
Hollow brick
Technical data
FSS flat-head
Code
2410 2408 2428 2411 2412 2413 2414 2415 2416 2417 2418 2419 2420 2429
Description
FSS 7,5x42 FSS 7,5x52 FSS 7,5x62 FSS 7,5x72 FSS 7,5x82 FSS 7,5x92 FSS 7,5x102 FSS 7,5x112 FSS 7,5x122 FSS 7,5x132 FSS 7,5x152 FSS 7,5x182 FSS 7,5x212 FSS 7,5x302
d0 mm
h1 mm
Øv x Lv mm
Øt mm
Ch mm
6 6 6 6 6 6 6 6 6 6 6 6 6 6
55 65 75 85 95 105 113 125 133 145 165 195 225 315
7,5x42 7,5x52 7,5x62 7,5x72 7,5x82 7,5x92 7,5x102 7,5x112 7,5x120 7,5x132 7,5x152 7,5x182 7,5x212 7,5x302
10,8-11,3 10,8-11,3 10,8-11,3 10,8-11,3 10,8-11,3 10,8-11,3 10,8-11,3 10,8-11,3 10,8-11,3 10,8-11,3 10,8-11,3 10,8-11,3 10,8-11,3 10,8-11,3
T30 T30 T30 T30 T30 T30 T30 T30 T30 T30 T30 T30 T30 T30
250
h1 Lv Øv d 0 Øt ch
= Min. hole depth = Screw length = Screw diameter = Hole diameter = Head screw diameter = Spanner
universal and frame fixings
Vorpa FSS-FSC
Through steel screw for windows frame
Concrete
Solid brick
Hollow brick
Aerated concrete
Technical data
FSC cylinder-head
T15 Art.
T25 Art.
T30 Art.
Description
2457 2471 2472 2460 2458 2459 2461 2462 2463 2464 2465 2466 2467 2468 2469 2470
32458 32459 32461 32462 32463 32464 32465 32466 32467 32468 32469 32470 32471 32472
FSC 5x62 FSC 5x82 FSC 5x112 FSC 7,5x42 FSC 7,5x52 FSC 7,5x62 FSC 7,5x72 FSC 7,5x82 FSC 7,5x92 FSC 7,5x102 FSC 7,5x112 FSC 7,5x122 FSC 7,5x132 FSC 7,5x152 FSC 7,5x182 FSC 7,5x212 FSC 7,5x252 FSC 7,5x302
d0 mm
h1 mm
Øv x Lv mm
Øt T25 mm
Øt T30 mm
4 4 4 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6
72 92 120 55 65 75 85 95 105 113 125 135 145 165 195 225 265 315
5x62 5x82 5x112 7,5x42 7,5x52 7,5x62 7,5x72 7,5x82 7,5x92 7,5x102 7,5x112 7,5x120 7,5x132 7,5x152 7,5x182 7,5x212 7,5x252 7,5x302
7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70
8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5
Installation data Embedment depth
Concrete
Solid brick
Hollow brick doppio UNI
Light weight concrete
hef ≥ 30 mm
hef ≥ 40 mm
hef ≥ 60 mm
hef ≥ 60 mm
Installation data Pull out values in daN Concrete C20/25 Solid brick EN 771-2 Italian standard hollow brick with plaster (doppio UNI EN 771-1) Aerated concrete
1 daN ≃1 kg ≥ 30 mm 320 -
≥ 40 mm 320 -
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.
251
≥ 60 mm 160 80
h1 = Min. hole depth Lv = Screw length Øv = Screw diameter d0 = Hole diameter Øt = Head screw diameter ch = Spanner T15 = Torx Recess 15 T25 = Torx Recess 25 T30 = Torx Recess 30
universal and frame fixings
Vorpa VG A
Steel frame fixing with screw
Concrete
Solid brick
Hollow brick
Natural stone
Products group VG A with flat-head screw
VG A with cylinder-head screw
To fix • Facades • Window frames • Door frames
Suitable for • Concrete • Solid brick • Natural stone
Installation sequence
Product information Characteristics • Metal frame anchor with metric screw for window and door frames
Benefits • By tightening the screw, the cone is drawn into the sleeve and the fixing is expanded which wedges it inside the drill hole Installation • Through setting anchors
Benefits • Ensures a stress-free and long-lasting fixing of frame • The special plug geometry anchors the metal and plastic profiles Suggestion for use • Always consider an appropriate safety factor against compressive and tensile loads • Check load bearing capacity values • Suitable for push-through installation • Respect the installation data • Clean the hole before the installation Technical data
VG A with flat-head screw Code
2267 2270 2266 2273 2268 2274 2269 2275 2276 2277 2278 2279 2280
VG A with cylinder-head screw
Description
dnom x Lt mm
h1 mm
hef mm
Tfix mm
d0 mm
df mm
8x92 8x112 8x72 8x92 8x112 8x132 8x152 10x72 10x92 10x112 10x132 10x152 10x182
90 90 90 90 90 90 90 90 90 90 90 90 90
60 60 60 60 60 60 60 60 60 60 60 60 60
25 45 5 25 45 65 85 5 25 45 65 85 115
8 8 8 8 8 8 8 10 10 10 10 10 10
8 8 8 8 8 8 8 10 10 10 10 10 10
VG A VG A VG A VG A VG A VG A VG A VG A VG A VG A VG A VG A VG A
8/92 TSC * 8/112 TSC * 8/72 TSP 8/92 TSP 8/112 TSP 8/132 TSP 8/152 TSP 10/72 TSP 10/92 TSP 10/112 TSP 10/132 TSP 10/152 TSP 10/182 TSP
Installation data Pull out values in daN Materials Concrete C20/25 Solid brick
1 daN ≃1 kg VG A Ø8 280 -
VG A Ø10 530 500
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values. 252
Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness df = Hole diameter in the fixture dnom = Plug diameter hef = Effective anchorage depth
universal and frame fixings
Vorpa VG N
Nylon frame fixing with screw
Concrete
Solid brick
Perforated brick
Hollow brick
Aerated Poroton
Products group To fix • Facades • Window frames • Door frames
Suitable for • Concrete • Solid brick • Perforated brick • Hollow brick • Aerated poroton • Perforated cement
Installation sequence
Product information Installation • Through setting anchors
Characteristics • Nylon frame anchor with metal screw for window and door frames Benefits • Ensures a stress-free and long-lasting fixing of frame • The special plug geometry anchors the metal and plastic profiles against compressive and tensile loads • Allows for a secure hold of the window frame • Suitable for push-through installation
Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation
Technical data
Code
266 273 268 274 275 276 277 278 279
Description
dnom x Lt mm
h1 mm
hef mm
Tfix mm
d0 mm
df mm
VG N 8/75 VG N 8/100 VG N 8/120 VG N 8/140 VG N 10/75 VG N 10/100 VG N 10/120 VG N 10/140 VG N 10/165
8x75 8x100 8x120 8x140 10x75 10x100 10x120 10x140 10x165
55 55 55 55 55 55 55 55 55
50 50 50 50 50 50 50 50 50
30 50 70 90 30 50 70 90 115
8 8 8 8 10 10 10 10 10
8 8 8 8 10 10 10 10 10
Installation data Pull out values in daN Materials Concrete C20/25 Solid brick Italian standard hollow brick with plaster (doppio UNI)
1 daN ≃1 kg VG N Ø8 300 280 80
VG N Ø10 520 480 120
ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values. 253
Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness df = Hole diameter in the fixture dnom = Plug diameter hef = Effective anchorage depth
universal and frame fixings
Vorpa CLAPS
fixing in plastic material for fixing frames and subframes Products group to fix • Window and door frames • Subframes • Doors - windows
Product information Characteristics • Fixng in plastic material for fixing frames and subframes
Benefici • alette guida che si adattano al particolare del fissaggio • blocco garantito del CLAPS sul telaio • fornita in una striscia di quattro pezzi collegati fra loro • inserimento facilitato e veloce
Technical data
Code
1870 1871 1872
Description
CLAPS 2 CLAPS 3 CLAPS 5
Thickness mm
Colour
2 3 5
neutral grey black
Ls L S P D A B
= = = = = = =
40 32 8 4 ,5 36 18 9
mm mm mm mm mm mm mm
Installation sequence
Place the subframe.
Insert the fixing of plastic material at the point of the window in which the fixing will be carried out.
254
Once the fixation has been completed, remove the unused claps.
universal and frame fixings
Vorpa VSL Steel screws
Wood
Products group To fix • Outside fittings • Covering • Big structures • Wood carpentry
Suitable for • Wood
ribs under head no pre-countersinking
extra-deep torx bit
high quality surface treatment for fast and easy application
milling thread reducing risk of splitting
cutting edge
fast screw pitch successfully reduced labor time by 40%
European Technical Approval EAD 130118-00-0603
Examples of applications
255
universal and frame fixings
Vorpa VSL Steel screws
Wood
Product information Characteristics • Wood building screw , TORX recess
Installation • Through-setting and pre-setting fixing
Benefits • Drilling is not necessary • Suitable for permanent and removable fixings both inside and outside • High performances in wood • No risk to make slits on the wood thanks to the milling body • Special pre-drilling design • Quick pitch thread
Suggestions for use • Choose the right size of the screw according to the load • Always check load bearing capacity values in the table • Respect the installation data
Installation sequence
Technical data
Code
Description
93264 93265 93266 93267 93268 93269 93270 93271 93272 93273 93274 93275 93276 93277 93278 93279 93280 93281 93282 93283 93284
VSL 4 VSL 4 VSL 4 VSL 4 VSL 4 VSL 4 VSL 4 VSL 4,5 VSL 4,5 VSL 4,5 VSL 4,5 VSL 4,5 VSL 5 VSL 5 VSL 5 VSL 5 VSL 5 VSL 5 VSL 5 VSL 6 VSL 6
x x x x x x x x x x x x x x x x x x x x x
30 40 45 50 60 70 80 40 50 60 70 80 40 50 60 70 80 100 120 60 80
Lv mm
dv mm
h1 mm
Tfix max mm
Characteristic resistance kN
*Recommended load kN
Ch Torx
30 40 45 50 60 70 80 40 50 60 70 80 40 50 60 70 80 100 120 60 80
4 4 4 4 4 4 4 4,5 4,5 4,5 4,5 4,5 5 5 5 5 5 5 5 6 6
20 24 27 30 36 42 48 24 30 36 42 48 24 30 36 42 48 60 70 36 48
10 16 18 20 24 28 32 16 20 24 28 32 16 20 24 28 32 40 50 24 32
0,78 0,94 1,06 1,18 1,41 1,65 1,88 1,06 1,32 1,59 1,85 2,12 1,18 1,47 1,76 2,06 2,35 2,94 3,43 2,12 2,82
0,19 0,23 0,26 0,29 0,35 0,41 0,47 0,26 0,33 0,39 0,46 0,53 0,29 0,36 0,44 0,51 0,58 0,73 0,85 0,53 0,70
T20 T20 T20 T20 T20 T20 T20 T25 T25 T25 T25 T25 T25 T25 T25 T25 T25 T25 T25 T30 T30
256
Lv dv Tfix Ch
= Screw length = Screw diameter = Fixture thickness = Spanner (impronta Torx)
Safety factor applied = 4 1 Kn = 100 kg approx. 1 Kn = 100 kg
universal and frame fixings
Vorpa VSL Steel screws
Wood
Technical data
Code
Description
93285 93286 93287 93288 93289 93290 93291 93292 93293 93294 93295 93296 93297 93298 93299 93300 93301 93302 93303 93304 93305 93306 93307 93308 93309 93310 93311 93312 93313 93314 93315 93316 93317 93318 93319 93320 93321 93322 93323 93324 93325 93326 93327
VSL 6 VSL 6 VSL 6 VSL 6 VSL 6 VSL 6 VSL 6 VSL 6 VSL 6 VSL 6 VSL 6 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
100 120 140 160 180 200 220 240 260 280 300 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400
Lv mm
dv mm
h1 mm
Tfix max mm
Characteristic resistance kN
*Recommended load kN
Ch mm
100 120 140 160 180 200 220 240 260 280 300 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400
6 6 6 6 6 6 6 6 6 6 6 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10
60 70 70 70 70 70 70 70 70 70 70 50 60 70 80 80 80 80 80 80 80 80 80 80 80 80 80 80 70 80 80 80 80 80 80 80 80 80 80 80 80 80 80
40 50 70 90 110 130 150 170 190 210 230 30 40 50 60 80 100 120 140 160 180 200 220 240 260 280 300 320 50 60 80 100 120 140 160 180 200 220 240 260 280 300 320
3,53 4,12 4,12 4,12 4,12 4,12 4,12 4,12 4,12 4,12 4,12 3,92 4,70 5,49 6,27 6,27 6,27 6,27 6,27 6,27 6,27 6,27 6,27 6,27 6,27 6,27 6,27 6,27 6,86 7,84 7,84 7,84 7,84 7,84 7,84 7,84 7,84 7,84 7,84 7,84 7,84 7,84 7,84
0,88 1,03 1,03 1,03 1,03 1,03 1,03 1,03 1,03 1,03 1,03 0,98 1,17 1,37 1,56 1,56 1,56 1,56 1,56 1,56 1,56 1,56 1,56 1,56 1,56 1,56 1,56 1,56 1,71 1,96 1,96 1,96 1,96 1,96 1,96 1,96 1,96 1,96 1,96 1,96 1,96 1,96 1,96
T30 T30 T30 T30 T30 T30 T30 T30 T30 T30 T30 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40
257
Lv dv Tfix Ch
= Screw length = Screw diameter = Fixture thickness = Spanner (impronta Torx)
Safety factor applied = 4 1 Kn = 100 kg approx. 1 Kn = 100 kg
universal and frame fixings
Vorpa VSL M extra short type Wood building screws with cylinder flat head
Wood
products group Suitable for • wood
flat head Ø 1,6cm
high quality surface treatment for fast and easy application
cutting edge
milling thread reducing risk of splitting
extra-deep torx bit
To fix • Covering • Big structures • Wood carpentry
fast screw pitch successfully reduced labor time by 40%
Examples of applications
product information Characteristics • wood building screws with cylinder flat head extra short type for safe applications on pillars Benefits • Drilling is not necessary • Suitable for permanent and removable fixings both inside and outside • High performances in wood technical data
Code
Description
93451 93452 93453 93454
VSL M 8 x 40 VSL M 8 x 50 VSL M 8 x 60 VSL M 8 x 80
Benefits • No risk to make slits on the wood thanks to the milling body • Special pre-drilling design • Quick pitch thread • the extra short size of the screw with head diameter 1,6 cm ensures safe applications on pillars reducing number of screws to be used. • the flat head screw allows a perfect alignment to the metal plates; when fixing on pillars it can be used as normal screw but the larger diameter head permits optimal grip and better pressure distribution of the fasten.
Lv mm
dv mm
h1 mm
Tfixmax mm
Characteristic resistance kN
Recommended load kN
Ch Torx
8x40 8x50 8x60 8x80
8 8 8 8
30 35 40 50
10 15 20 30
1,80 2,40 3,10 3,92
0,45 0,60 0,77 0,98
40 40 40 40
258
Lv = Screw length dv = Screw diameter h1 = Min. hole depth tfix = Fixture thickness Ch = Torx + bit Safety factor applied = 4
Scaffolding anchors
scaffolding anchors
Vorpa TOP T
Steel anchors with eyebolt Ø 50 for scaffolds standing on the ground
Concrete
Solid brick
Natural stone
products group Suitable • concrete • solid brick • natural stone
To fix • scaffolding standing on the ground
Test report available
Software Vorpa Calcul Anchor Examples of applications
product information Characteristics • Torque controlled expansion anchor made of galvanized steel composed of anti-rotation cold formed body, expansion conical nut and eyebolt Ø 50 Benefits • The eyebolt can be used several times thanks to the anchor spare part • The cap hole covering enables to cover off holes at the end of the work in a quick and simple way • Eyebolt neck with flat slot to tight by wrench • Anti-rotation during the installation procedure
Benefits • Three-part expansion sleeve allows even load distribution and small edge and axial spacing Installation • To be mounted aligned the wall Suggestion for use • Make sure the scaffold and eyebolt are well positioned each other • Apply a proper safety factor according to the each situation • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
260
scaffolding anchors
Vorpa TOP T
Steel anchors with eyebolt Ø 50 for scaffolds standing on the ground
Concrete
Solid brick
installation sequence 1) installation procedure
Drill the masonry.
Clean the hole by using proper cleaning brushes and pump.
Insert the anchor in the hole. Screw the eyebolt applying the correct torque and set the washer aligned to the wall.
2) to re-use the eyebolt
Unscrew the eyebolt and pull it out.
Installation completed.
Close the hole with the proper cap.
technical data
Code
837 838
Description
d0 mm
Lt mm
h1 mm
Tinst mm
Øi mm
l mm
ch mm
TOP T 12/130 TOP T 12/180
18 18
130 180
140 190
75 75
50 50
100 100
22 22
art 713
art 91294
art 91057
art 1896
Code
Type
d0 mm
Lengt mm
713 91294 91057 1896
TOP 12 - Ø 18 Ø 18 steel washer Ø 18 steel spacer Cap hole covering
18
75
Sizes mm
C mm
18x45x3 18x54x2 18
75
22
Installation data Pull-out values in daN for applications on concrete C20/25 TOP T
1 daN ≃1 kg
4.500
ATTENTION: An appropriate safety factor ≥ 3 should be applied on these values. As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.
261
Øv = Internal eyebolt diameter l = Axial spacing h1 = Min. hole depth Lt = Anchor length d0 = Hole diameter Tinst = Torque ch = spanner
Natural stone
scaffolding anchors
Vorpa eyebolt VN
welded eyebolt for scaffolds standing on the ground
Concrete
Solid brick
Natural stone
gruppo prodotti Suitable for: • concrete • solid brick • natural stone VN P eyebolt Ø 23
To fix: • scaffolds standing on the ground • tensioning ropes • chains
Test reports available
VN PX eyebolt Ø 50
Examples of applications
product information Charateristics • Galvanized steel welded eyebolt to be used with nylon plugs. Suitable for scaffolds standing on the ground Benefits • The eyebolt can be used several times thanks to the anchor spare part • High load-bearing capacity is achieved by using it with the proper nylon fixing • The anchor grants safe and easy applications thanks to mark on the eyebolt stem enabling a right embedment depth during the anchoring
Benefits • Wide range of eyebolts for every requirement • The cap hole covering enables to cover off holes at the end of the work in a quick and simple way. Installation • To be mounted aligned with the mark on the eyebolt body Suggestions for use • Make sure the scaffold and the eyebolt are well positioned each other • Apply a proper safety factor according to the each situation • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
262
scaffolding anchors
Vorpa eyebolt VN
welded eyebolt for scaffolds standing on the ground
Concrete
Solid brick
Natural stone
installation sequence 1) Installation procedure
Drill the masonry.
Clean the hole by using proper cleaning brushes and pump.
Insert the nylon plug in the hole.
Screw the eyebolt applying the correct torque.
2) To re-use the eyebolt
Installation completed.
Unscrew the eyebolt and pull it out.
Close the hole with the proper cap.
technical data
VN P eyebolt Ø 23
Code
836 2837 2838 2834 2835 2836 2854 2855 2856
Description
VN P VN P VN P VN P VN P VN P VN P VN P VN P
12/120 12/160 12/190 12/230 12/300 12/350 12/400 12/450 12/500
d0 Ø mm
h1 mm
hef mm
ØvxLo mm
hef+l mm
Øtxlt mm
Ø mm
Tinst mm
14 14 14 14 14 14 14 14 14
115 115 115 115 115 115 115 115 115
100 100 100 100 100 100 100 100 100
12x120 12x160 12x190 12x230 12x300 12x350 12x400 12x450 12x500
145 185 215 255 325 375 425 475 525
14x100 14x100 14x100 14x100 14x100 14x100 14x100 14x100 14x100
23 23 23 23 23 23 23 23 23
19 19 19 19 19 19 19 19 19
VN P eyebolt Ø 50
Code
3836 3837 3838 3839
Description
VN PX 12/120 VN PX 12/160 VN PX 12/190 VN PX 12/230
d0 Ø mm
h1 mm
hef mm
ØvxLo mm
hef+l mm
Øtxlt mm
Ø mm
Tinst mm
14 14 14 14
115 115 115 115
100 100 100 100
12x120 12x160 12x190 12x230
155 200 240 265
14x100 14x100 14x100 14x100
50 50 50 50
19 19 19 19
263
Øv = Eyebolt diameter Lo = Eyebolt length I = Axial spacing hef = Min. anchorage depth h1 = Min. hole depth Lt = Anchor length d0 = Hole diameter Øt = Anchor diameter Tinst = Torque
scaffolding anchors
Vorpa eyebolt VN
welded eyebolt for scaffolds standing on the ground
Solid brick
spare parts
art 820 - 635R
Code
635R 820 2840
art 2840
Type
d0
VN 14/75 VN 14/100 CFP cap hole covering
14 14 12/14
Length mm
C mm
75 100 37
26
installation data Pull-out values in daN for applications on concrete C20/25 using a nylong plug VN 14/100
1 daN â&#x2030;&#x192;1 kg
VN P / VN PX 1.300 ATTENTION: An appropriate safety factor > 5 should be applied on these values. As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.
264
Natural stone
scaffolding anchors
Vorpa eyebolt OS 8 Ø23
welded eyebolt for scaffolds standing on the ground
Concrete
Solid brick
Natural stone
products group Suitable for: • concrete • solid brick • natural stone
To fix: • scaffolds standing on the ground • tensioning ropes • chains
Insert the nylon plug in the hole.
Screw the eyebolt applying the correct torque and set the washer aligned to the wall.
eyebolt OS 8 Ø23
installation sequence 1) Installation procedure
Drill the masonry.
Clean the hole by using proper cleaning brushes and pump. 2) To re-use the eyebolt
Installation completed.
Unscrew the eyebolt and pull it out.
Close the hole with the proper cap.
product information Charateristics • Galvanized steel welded eyebolt to be used with nylon fixings Suitable for scaffolds standing on the ground Benefits • The eyebolt can be used several times thanks to the anchor spare part
Suggestions for use • Make sure the scaffold and the eyebolt are well positioned each other • Apply a proper safety factor according to the each situation • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
Installation • To be mounted aligned with the mark on the eyebolt body
265
scaffolding anchors
Vorpa eyebolt OS 8 Ø23
welded eyebolt for scaffolds standing on the ground
Concrete
Solid brick
technical data
eyebolt OS 8 Ø 23
Code
1990 1991 1992
Description
OS 8 Ø23 8/80 OS 8 Ø23 8/100 OS 8 Ø23 8/120
d0 Ø mm
h1 mm
hef mm
ØvxLo mm
hef+l mm
Øtxlt mm
Ø mm
Tinst mm
12 12 12
75 75 75
60 60 60
8x80 8x100 8x120
100 120 140
12x60 12x60 12x60
23 23 23
15 15 15
Øv = Eyebolt diameter Lo = Eyebolt length I = Axial spacing hef = Min. anchorage depth h1 = Min. hole depth Lt = Anchor length d0 = Hole diameter Øt = Anchor diameter Tinst = Torque
accessories
art 634
Art
634 2840
art 2840
Tipo
d0
VN 12/60 CFP cap hole covering
12 12/14
Length mm
C mm
60 37
26
installation data Pull-out values in daN for applications on concrete C20/25 using a nylong plug VN 12/60
1 daN ≃1 kg
OS 8 Ø23 1.020 ATTENTION: An appropriate safety factor > 5 should be applied on these values. As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.
266
Natural stone
scaffolding anchors
Vorpa VSP P
steel anchors with eyebolt Ø 23 for scaffolds standing on the ground
Concrete
Solid brick
Natural stone
product group Suitable • concrete • solid brick • natural stone
To fix • scaffolds standing on the ground • tensioning ropes • chains
Test reports available Examples of applications
product information Characteristics • Galvanized steel welded eyebolt Ø 23 with VS-P or VSX expansion body
Benefits • High tensile loads with standard depth • The cap hole covering enables to cover off holes at the end of the work in a quick and simple way
Benefits • The eyebolt can be used several times thanks to the anchor spare part • The special nylon washer avoids the seepage of water through the external hole • The anchor grants safe and easy applications thanks to mark on the eyebolt stem enabling a right embedment depth during the anchoring • Smooth expansion thanks to the three cuts on the expansion body
Installation • To be mounted aligned with the mark on the eyebolt body Suggestion for use • Make sure the scaffold and the eyebolt are well positioned each other • Apply a proper safety factor according to the each situation • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
267
scaffolding anchors
Vorpa VSP P
steel anchors with eyebolt Ø 23 for scaffolds standing on the ground
Concrete
Solid brick
Natural stone
installation sequence 1) installation procedure
Drill the masonry.
Clean the hole by using proper cleaning brushes and pump.
Insert the anchor in the hole.
Screw the eyebolt applying the correct torque and set the washer aligned to the wall. Øv = Eyebolt internal diameter hef = Min. anchorage depth h1 = Min. hole depth d0 = Hole diameter tinst = Torque
Installation completed.
technical data
Code
9882 9880 881
Description
d0 mm
h1 mm
hef mm
axial spacing hef+l
Øi mm
expansion body M8
Tins mm
VSP P 12/130 VSP P 12/180 VSP P 12/215
12 12 12
80 95 85
80 80 80
130 180 215
23 23 23
12x45 12x55 12x45
25 25 25
spare parts Code
2833 3972 2840
d0 mm
Type
Washer 12x32x4 VSP 12 M8 CFP cap hole covering
12 12/14
Length mm
C mm
code 3972
37
26
Installation data
code 2840
Pull-out values in daN for applications on concrete C20/25 VSP P
code 2833
1 daN ≃1 kg
1.500
ATTENTION: An appropriate safety factor ≥ 3 should be applied on these values. As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department. A too high torque moment during the installation may cause permanent deformations and even the breaking of the threaded part affecting the eyebolt resistance.
268
scaffolding anchors
Vorpa scaffold tester 25 kN product group Suitable • medium duty tester 25 kN tension for pull out tests on scaffolding anchors and chemical anchors
product information Characteristics • Tester with fixed gauge calibrated to 25 kN with maximum load indicator • Load spreading bridge feet granting the proper positioning in every situation • Compact and pratical, it grants safety and reliability • Strong rectangular stand • Maximum tensile load 25 kN • Calibration Certificate • Supplied in a Plastic Carrying Case • Weight 10 kg, dimension cm 55x39x14
technical data
accessories
Accessories Carrying case Code Code
Description
6500D
Tester 25 kN
Description
6517 25 kN analogic gauge 6518 25 kN digital gauge
Load gauge Indication of pull-out load Calibrated in kn Traceable calibration certificate supplied with each guage
Protective rubber cover Impact resistant glass Protection against sudden load relief (i.e. sudden failure of fixing)
Kit contents 25 kN Gauge Load Spreading Bridge with level bubbles Hex Legs with leg extension adjustment Swivel Feet M12 Locking Adaptor M12 Ringbolt Adaptor Clevis
Bolt Test Adaptor Threaded Stud Adaptor Operating Instructions Calibration Certificate Oil Bottle
269
scaffolding anchors
Vorpa mid heavy duty tester 50 kN product group Suitable • the new tester features a 50 kN (5 ton) analogue gauges as standard. Digital gauges are also available.
product information Characteristics • Medium duty tester 50kN tension for pull out tests on scaffolding anchors and chemical anchors. • Increased gauge scope - The new tester 50 kN tester features a 50kN(5 ton) analogue gauge as standard. Digital gauges are also available. • Turning handle - A new turning handle has been developed to accomodate the larger load. It offers a larger handle for ease of use and features an integrated M24 opearating nut for use with a ratchet spanner for operation in confined spaces. • Reinforced load spreading bridge - To sustain a 50kN load a new robust bridge design has been made which is denser in profile. It features three telescopic legs with pin arrangement in six positions and 30mm of fine adjustment at the base.
technical data
accessories
Accessories Kit tester 50kN Code Code
6511
Description
Description
• Analogic gauge 50 kN • Digital gauge 50 kN
Tester 50 kN
Kit contents Threaded Stud Adaptors New longer design M16, M20 and M24 as standard with optional M10, M12 and M30 Slotted Button Adaptors 6.8, 8.5, 10.5, and 12.5 as standard with optional 4.5 and 5.5
Threaded Button Adaptors M10 and M12 as standard with optional M4, M5, M6 and M8 Ringbolt Adaptor Clevis (optional) Rated to 50kN
270
scaffolding anchors
Vorpa scaffold tester 145kN products group Suitable The portable self-contained 145kN Heavy Duty Tester has been designed to meet the demand for proof load testing of larger construction fixings. A lightweight triangular shape aluminium load spreading bridge has been designed specifically for the model 145 kN tester and directs reaction loads away from the fixing, this combined with the tester weighs only 14kg. Load application is achieved via a ratchet handle driving a hydraulic multiplier and the applied load is recorded on a digital gauge which is integral with the tester. This compact design of tester and load spreading bridge is lighter and more convenient to apply than a separate hydraulic pump and cylinder arrangement.
product information Characteristics â&#x20AC;˘ Heavy duty tester 145 kN tension for pull out tests on heavy duty anchors and chemical anchors
technical data
Metal carrying case
Code
6502
Description
Scaffold Tester 145 kN
Kit contents Operating Nut Digital Gauge Load spreading Bridge with 10mm eye hook 3 adjustable legs with swivel feet 22mm Ratchet Spanner
5 Threaded Adaptors M12, M16, M20, M24, M30 Spirit Level Carry Case with Filler Operating Instructions Calibration Certificate
271
safety swing hook for antifalling
Vorpa AC M12 Hooks - wood hook safety hooks with steel anchors for anti-fall nets
Concrete
Solid brick
Natural stone
Boards and panels
Glulam GL24h
product group
art. 9315 Steel expansion body TOP M12 Ø18 ETA op.7
Suitable • concrete • solid brick • natural stone • boards and panels • wood lamella GL24h
art. 9316 Steel expansion body VHS M12 Ø16 ETA op.8
Tested by
Test report available AC M12 n° 3279510 In accordance with EN 1263
art. 9317 Steel expansion body VA CE M12 Ø15 ETA op. 7
art. 9331 Safety swing hook with 2 nuts and washer
Tested by art. 9322 Safety swing hook with wood screw
Test report available AC Ø10 n° 332232 Example of application
Product information Features • Safety hook with an innovative concept. The particular fold given to the hook ensures closure of the same, once the load of fall on the network it reaches the value of 700 daN on concrete and 450 daN on laminated wood Benefits • Possibility to insert and unfasten the fall prevention cable on the hook once made the fixing • The hook is recovered once the work is finished • High loadability thanks to the adaptation of the eyelet to the anchor • Wide selection of expanding bodies • Wide range of assortment of hooks and anchors
Suggestion for use • Choose the most suitable accessory in relation the application to carry out • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
272
safety swing hook for antifalling
Vorpa AC M12 Hooks - wood hook safety hooks with steel anchors for anti-fall nets
Concrete
Solid brick
Natural stone
installation sequence installation sequence for AC TOP Ø18
installation sequence for AC VA CE Ø15
technical data
B
art. 9315 mechanical anchor TOP M12 Ø18 assesment for non-cracked concrete
Code
Description
9315 AC TOP Ø18
Lt mm
do mm
h1 mm
I mm
Thread mm
A B C mm
Tinst Nm
75
18
85
80
M12
26 - 160 - 13
50
A
C
C = passage of the rope
art. 9316 mechanical anchor VHS M12 Ø16 assesment for non-cracked concrete
B
A
Code
Description
9316 AC VHS Ø16
Lt mm
do mm
h1 mm
I mm
Thread mm
A B C mm
Tinst Nm
70
16
80
80
M12
26 - 160 - 13
40
C
C = passage of the rope
art. 9317 mechanical anchor VA CE M12 Ø15 assesment for non-cracked concrete
Code
Description
9317 AC VA CE Ø15
Lt mm
do mm
h1 mm
I mm
Thread mm
A B C mm
Tinst Nm
50
15
55
75
M12
26 - 140 - 13
35
C = passage of the rope
273
B
A
C
safety swing hook for antifalling
Vorpa AC M12 Hooks - wood hook safety hooks with steel anchors for anti-fall nets
Boards and panels
technical data B Tfix
art. 9331 safety hook with nuts and washers
A
C
Code
9331
Description
AC M12 DR
Thread mm
L Thread mm
I mm
H1 mm
Tfix max mm
A B C mm
M12
65
75
55
35
22 - 140 - 13
C = passage of the rope
Example of application
accessories Code
Description
screws Ø mm
d0 mm
Lt mm
h1 mm
TOP M12 Ø18
713
TOP 12
M12
18
75
85
VHS M12 Ø16
51160
VHS 12
M12
16
70
80
VA M12 Ø15
99593
VA CE 12
M12
15
50
55
VA F M12 Ø15 with neck
98594
VA F CE 12
M12
15
50
55
299
PERCUSSION TOOL FOR ANCHOR 99593 - 98594
technical data Concrete C20/25 Determination of the resistance at the safety hook opening M12 with anchor VORPA AC M12
720 daN
Notice: the hook (1) is closed at the indicated load. The complete opening of the hook is determined at the maximum load of 1500 daN (2) 1) Behavior of the hook with pull-out up to 720 daN
2) Behavior of the hook with pull-out 1500 daN
274
1 daN ≃1 kg
safety swing hook for antifalling
Vorpa AC L Ø10 hooks
safety hooks with steel anchors for anti-fall nets
Glulam GL24h
technical data
ØD
art. 9322 safety hook for application on wood structures
Code
Description
9322
hnom do1 x h1 do2 x h2 mm Øxmm Øxmm
70
AC LEGNO Ø10
Ø7x70
Ø10x15
Test reports available
hmin mm
L Thread mm
ØD mm
A B C mm
80
45
10
22 - 160 - 13
C = passage of the rope hmin B A do2 do1 h2
do1 x h1 = do2 x h2 = hmin = hnom = L filetto = ØD =
Pre-hole diameter x length Second pre-hole diameter x length Minimum thickness in the wood/beam Minimum embedment in the beam Thread length Stem of the hook
C
h1 hnom
Example of application
installation sequence ACL hook on wooden material 70 mm
15 mm
Ø7
Pre hole with drill Ø7
Ø10
Pre hole with drill Ø10
Thighten up to the dark
Insert the cable into the hook
technical data 1 daN ≃1 kg Determination of the resistance on laminated wood GL 24h
700 daN
Use a safety factor ≥3 275
safety swing hook for antifalling
Vorpa AC M12 Hooks - wood hook safety swing hook for anti falling net
Concrete
Solid brick
Natural stone
Boards and panels
Glulam GL24h
installation sequence Correct sequence
1) Standing in front of the hook, grab the net with both hands and place it under the hook opening.
2) The part of the network, held by the right hand, must enter the open hook on the left.
3) Hold the net with both hands pulling the ends to facilitate the move into the hook.
4) The network has entered into the hook. proceed to the next hook.
5) The network is entered correctly into the support hooks
Wrong sequence
NO
NO
1) The network is placed in front of the hook opening. NO
2) The network is placed behind the opening of the hook. NO
276
safety swing hook for antifalling
Vorpa ACR M12 safety hook safety hooks with steel anchors for anti-fall nets
Concrete
product group
Solid brick
Natural stone
Boards and panel
Example of application Steel expansion body TOP CE
Steel expansion body VA CE
With 2 nuts and washer
Suitable • concrete • solid brick • natural stone • boards and panels • prestressed concrete plates with honeycomb core
Tested by
Test report available
Product information Characteristics • System composed of a steel curly hook and steel anchor for ropes and anti-falling nets on pillars, beams and solid walls Benefits • Possibility to insert and unfasten the fall prevention cable on the hook once made the fixing • The hook is recovered once the work is finished
Suggestion for use • Choose the most suitable accessory in relation the application to carry out • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
installation sequence ACR TOP on solid material
ACR VA on thin solid brick
277
safety swing hook for antifalling
Vorpa ACR M12 safety hook safety hooks with steel anchors for anti-fall nets
Concrete
Solid brick
Natural stone
Boards and panel
technical data
Steel expansion body TOP CE
Code
Description
9340 ACR M12 TOP 18 9326 ACR M10 TOP 14
d0 Lt Ø mm mm
18 14
75 60
h1 mm
l Thread Øg mm mm mm
85 70
55 40
Øi mm
M12 10,7 13 M10 9 13
Lg mm
Tins Nm Lt = Anchor length h1 = Min. hole depth d0 = Hole diameter Øg = Stem of the hook Øi = Passage of the rope Lg = Total length of the hook l = Axial spacing Tinst = Torque
150 50 135 30
Steel expansion body VA CE
Lg
Description
Lt mm
d0 mm
h1 mm
l Thread Øg mm mm mm
9341 ACR M12 VA 15
50
15
55
55
Code
Øi mm
Lg mm
Tins Nm
M12 10,7 13 110
35
Example of application With 2 nuts and washer
Code
Description
9342 ACR DR M12 hook
Thread length mm
Thread mm
I mm
42
M12
55
Øg mm
Lg mm
Øi mm
10,7
110
13
accessories Code
Description
for screws Ø mm
d0 mm
Lt mm
h1 mm
713 712
TOP 12 TOP 10
M12 M10
18 14
75 60
85 70
593
VA M12 Ø15
M12
15
50
55
technical data 1 daN ≃1 kg
Determination of the resistance at the safety hook ACR M12 TOP - ACR M12 VA ACR M10 TOP
600 daN 350 daN 278
safety swing hook for antifalling
Vorpa BEAM clamp for anti-falling fixings Clamp for anchoring to beams for the fixing of hooks for anti-falling nets
Iron beams IPE structures
product group Suitable for • iron beams • IPE structures • Metal carpentry
To fix • threaded accessories M8/M10/M12 • tensioning ropes • fall protection nets • industrial plant engineering • conducting installations, plumbing and drains
technical data Code
Description
A mm
B mm
C mm
D mm
E mm
F mm
G mm
H mm
Max load anchor point kg
Certification
89004 9335 9336
Steel clamp M 8 Steel clamp M10 Steel clamp M12
21 23 35
19 21 23,5
35 42 54
M8 M10 M12
35 41 48
M8 M10 M10
18 20 26
38 44 58
120 250 350
Vds - UL VdS - UL - FM VdS - UL - FM
Steel clamp with through threaded hole and hedgehog safety hook M10
Steel clamp with through threaded hole and M12 safety hook
examples of application
279
Fixings for insulation
fixings for insulation
Vorpa VP L 60 e 95 insulation panels fixings
Polystyrene Extruded panels polystyrene
products group Suitable • Polystyrene panels • Extruded polystyrene • Heat insulating and soundproofing panels
VP L 60
To fix • Plumbing and light flues • External wall lighting • Shop-signs and traffic-signs • Postboxes
Ideal for applications on compact masonry covered by heat insulating panels and rigid insulation materials whose minimum thickness is 60 mm.
VP L 95
product information Charateristics • Nylon light fixing to be used on masonry covered by rigid insulating panels
Installation • To be mounted aligned with the insulation panels by screwing and without pre-drilling
Benefits • Made of chemical agents resistant and paintable nylon • Easy and quick installation by T40 bit or hexagonal head screw M8 • No need to pre-drill • Ideal also for applications on ETICS systems • Ideal to fix rigid insulation materials whose minimum thickness is 60mm • Possibility to remove the object to maintenance without compromise the anchoring resistance • The fixing material prevents the thermal bridge phenomenon, avoiding heat waste.
Suggestions for use • In order to prevent the seepage of water in the insulation material, the plug’s edge must be sealed with acrylic sealant or silicone after the installation has been completed • When VPL fixing is mounted aligned with the insulation panels, the object to be fixed must be anchored by: - VPL 60: frame screw Ø 4,5 or 5,5 mm - VPL 95: metrical screw M8 and Ø 8 and 10 mm
installation sequence
Point the fixing on the masonry
Screw by using a drill without pre-drilling
Screw the frame screw inside VP L fixing
Examples of applications
Examples of applications
281
Installation completed
fixings for insulation
Vorpa VP L 60 e 95 insulation panels fixings
Polystyrene Extruded panels polystyrene
technical data
Code
4521
Description
Lt mm
bit
screw ø mm
screw length mm
S mm
VP L 60
58
Torx T40
4,5 - 5,5
30 + Tfix
≥ 60
M
Ø Lv
dv xLv mm
Thread
To be used on
4x40 5,5x40*
M6 M8
VPL 60 VPL 60
Code
Description
92224 92273
Screw M6x40 Screw M8x40
Code
Description
Lt mm
bit
screw ø mm
screw length mm
S mm
VP L 95
97
hex. head screw 13
M8 Ø 8-10
40 + Tfix
≥ 100
4522
Accessories VP L 95
Hexagonal bolt screw
Hexagonal bolt wood screw
Double thread screw
installation technical data Installation conditions
Base material thickness Min insertion of the screw in the plug Max insertion of the screw in the plug
VPL 60 mm ≥ 60 mm 30 mm 50
VPL 95 mm ≥ 100 mm 40 mm 80 1 daN ≃ 1 kg
Recommended loads daN Fixing type Base material Polystyrene PS 15 Polystyrene PS 20
VPL 60
VPL 95
4,0 5,0
9,0 10,0
282
Lt = Anchor length Tfix = Fixture thickness S = Insulation material thickness dv = Screw diameter Lv = Screw length
fixings for insulation
Vorpa PVC spacer
PVC spacer for fastenings on insulated walls product group Suitable for • thermal panels • acoustic panels • glass wool panel
To fix • brackets • profiles • fixings on coated walls • threaded bars
Examples of application
Fixing on hollow material with perforated sleeve
Product information Characteristics • PVC spacer for fastenings • Rigid and soft panels, to be used as support fixing for traditional systems • Fixing with threaded bars, chemical anchors on coated walls
Code
1163 1164 Code
1225 1226 1227 1228 Code
1229 1230 1231 1232
• Various lenghts available 1 meter, 10 mm, 30 mm, 50 mm, 100 mm
L mm
external diameter
internal hole diameter
Threaded bar Ø mm
1000 1000
35 45
15 20
12-14 16-20
Description
L mm
external diameter
internal hole diameter
Threaded bar Ø mm
PVC spacer Ø35x10 PVC spacer Ø35x30 PVC spacer Ø35x50 PVC spacer Ø35x100
10 30 50 100
35 35 35 35
15 15 15 15
12-14 12-14 12-14 12-14
Description
L mm
external diameter
internal hole diameter
Threaded bar Ø mm
PVC spacer Ø45x10 PVC spacer Ø45x30 PVC spacer Ø45x50 PVC spacer Ø45x100
10 30 50 100
45 45 45 45
20 20 20 20
16-20 16-20 16-20 16-20
Description
PVC spacer Ø35x1000 PVC spacer Ø45x1000
283
• Pierce wall and insulation panel • Pierce the insulation panel Ø35 o Ø45 as the desired PVC spacer
fixings for insulation PANELS
Vorpa ISO CE 8 NYLON
Light fixings for insulation panels with European Technical Assesment
Polystyrene panels
BASE MATERIALS
Concrete
Aerated concrete blocks
Lightweight aggregate blocks
Solid bricks Clay bricks
Hollow bricks
Product group Approved for • Concrete • Aerated concrete blocks • Lightweight aggregate blocks • Solid bricks / Clay bricks • Hollow bricks
To fix • Polystyrene panels • Extruded polystyrene
Ideal for applications on masonry coated by solid heat insulating panels and insulation materials. ETAG 014
A-B-C-D-E
Examples of applications
Examples of applications
Product information Characteristics • Polyamide fixing with fiberglass reinforced polyamide pin for all types of solid insulation materials. Use categories A-B-C-D-E.
Benefits • Product with European Technical Approval for use materials categories A-B-C-D-E
Benefits • Reduced thermal transfer • Easy and quick installation, the expansion is carried out by hammering the pin inside the nylon fixing • Reduced embedment depth enables reduced drilling times • Special washer Ø 140 permits the fixing on lightweight insulation materials • Special fiberglass reinforced polyamide pin
Installation • To be mounted aligned the wall Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • When calculating the usable length it is suggested to take into consideration eventual extra thicknesses such as glues, sealants, old plasters
Installation sequence
Wait till the sealant between the insulation panel and the base material is completely dry
Drill the base material with an appropriate drill bit
Insert the nylon fixing without pin until the washer rests again the insulation
284
Fix the pin by hammering gently until full expansion, i.e. when the head is leveled with washer surface
fixings for insulation PANELS
Vorpa ISO CE 8 NYLON
Light fixings for insulation panels with European Technical Assesment
BASE MATERIALS
Concrete
Polystyrene panels
Aerated concrete blocks
Lightweight aggregate blocks
Solid bricks Clay bricks
Hollow bricks
Technical data
Code
5775 5776 5777 5778 5779 5780
Description
Lt d0 mm mm
ISO CE 8 NY 8/95 ISO CE 8 NY 8/115 ISO CE 8 NY 8/135 ISO CE 8 NY 8/155 ISO CE 8 NY 8/175 ISO CE 8 NY 8/195
95 115 135 155 175 195
1) = Use categories A.B,C,D 2) = Use category E
8 8 8 8 8 8
h1 mm
hef mm
Tfix mm
≥351)/≥752) ≥351)/≥752) ≥351)/≥752) ≥351)/≥752) ≥351)/≥752) ≥351)/≥752)
≥251)/≥652) ≥251)/≥652) ≥251)/≥652) ≥251)/≥652) ≥251)/≥652) ≥251)/≥652)
Lt-hef-Ttol Lt-hef-Ttol Lt-hef-Ttol Lt-hef-Ttol Lt-hef-Ttol Lt-hef-Ttol
P mm
T T T T T T
+T +T +T +T +T +T
ØT dp Lnp b mm mm mm mm
+h +h +h +h +h +h
fix
tol
ef
fix
tol
ef
fix
tol
ef
fix
tol
ef
fix
tol
ef
fix
tol
ef
60 60 60 60 60 60
4,8 4,8 4,8 4,8 4,8 4,8
100 120 140 160 180 200
44 44 44 44 44 44
hmin = 100 mm Cmin = 100 mm Smin = 100 mm
Ancillaries
Code
Description
ØT mm
55762
ISO DISCO CE 140
140
Installation data Pull out values in daN Materials C12/15 concrete C16/20 - C50/60 concrete Clay bricks / calcium silicate bricks Calcium Silicate hollow blocks Vertically perforated clay bricks Porotherm 25 Lightweight aggregate concrete blocks LAC Autoclaved aerated concrete elements AAC2 Autoclaved aerated concrete elements AAC7
1 daN ≃1 kg Class A A B C C C D E E
Density Kg/dm3 ≥ 2.25 ≥ 2.30 ≥ 2.00 ≥ 1.60 ≥ 1.20 ≥ 0.80 ≥ 0.88 ≥ 0.35 ≥ 0.65
daN 50 75 75 75 60 40 60 75 90
Characteristic loading values according to ETA Recommended safety factor = 2 ETAG 014 light fixings Use category A B C D E
Building materials Normal weight concrete Solid masonry - Silicate blocks Hollow or perforated masonry Lightweight aerated concrete Autoclave aerated concrete
285
Lt = Anchor length h1 = Min. hole depth d0 = Hole diameter hef = Embedment depth Tfix = Fixture thickness P = Total depth of holes dp = Pin diameter Lnp = Pin length b = Pin’s knurling length Ttol = Thickness of equalizing and/ or non-load-bearing layer hmin = Min. base material thickness Smin = Min. anchor spacing Cmin = Min. edge distance
fixings for insulation PANELS
Vorpa ISO CE 8
Light fixings for insulation panels with European Technical Assesment
Mineral wool lamella
Mineral wool
BASE MATERIALS
Polystyrene panels
Extruded polystyrene
Concrete
Aerated concrete blocks
Lightweight aggregate blocks
Solid bricks Clay bricks
Hollow bricks
Product group Approved for • Concrete • Aerated concrete blocks • Lightweight aggregate blocks • Solid bricks / Clay bricks • Hollow bricks
To fix • Mineral wool lamella /mineral wool • Polystyrene panels • Extruded polystyrene
Ideal for applications on masonry coated by heat insulating panels and insulation materials. ETAG 014
A-B-C-D-E
Examples of applications
Examples of applications
Product information Characteristics • Polyamide fixing with white galvanized steel pin with head coated with plastic suitable for all types of insulation materials. Use categories A-B-C-D-E. Benefits • Reduced thermal transfer due to plastic endings of metal pin • Easy and quick installation, the expansion is carried out by hammering the pin inside the nylon fixing • Reduced embedment depth enables reduced drilling times • Special washer Ø 140 permits the fixing on lightweight insulation materials • Pin’s head covered by fiberglass reinforced polyamide
Benefits • Product with European Technical Approval for use materials categories A-B-C-D-E • The steel pin is suitable for all types of insulation materials and particularly for rigid insulation materials Installation • To be mounted aligned the wall Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • When calculating the usable length it is suggested to take into consideration eventual extra thicknesses such as glues, sealants, old plasters
Installation sequence
Wait till the sealant between the insulation panel and the base material is completely dry
Drill the base material with an appropriate drill bit
Insert the nylon fixing without pin until the washer rests again the insulation
286
Fix the pin by hammering gently until full expansion, i.e. when the head is leveled with washer surface
fixings for insulation PANELS
Vorpa ISO CE 8
Light fixings for insulation panels with European Technical Assesment
Mineral wool lamella
Mineral wool
BASE MATERIALS
Polystyrene panels
Concrete
Extruded polystyrene
Aerated concrete blocks
Lightweight aggregate blocks
Solid bricks Clay bricks
Hollow bricks
Technical data
Code
5747 5748 5749 5750 5751 5752
Description
Lt mm
d0 mm
h1 mm
hef mm
Tfix mm
P mm
ISO CE 8 8/95 ISO CE 8 8/115 ISO CE 8 8/135 ISO CE 8 8/155 ISO CE 8 8/175 ISO CE 8 8/195
95 115 135 155 175 195
8 8 8 8 8 8
≥351)/≥752) ≥351)/≥752) ≥351)/≥752) ≥351)/≥752) ≥351)/≥752) ≥351)/≥752)
≥251)/≥652) ≥251)/≥652) ≥251)/≥652) ≥251)/≥652) ≥251)/≥652) ≥251)/≥652)
Lt - hef - Ttol Lt - hef - Ttol Lt - hef - Ttol Lt - hef - Ttol Lt - hef - Ttol Lt - hef - Ttol
Tfix+Ttol+hef Tfix+Ttol+hef Tfix+Ttol+hef Tfix+Ttol+hef Tfix+Ttol+hef Tfix+Ttol+hef
1) = Use categories A.B,C,D 2) = Use category E
ØT dp Lnp mm mm mm
60 60 60 60 60 60
4,8 4,8 4,8 4,8 4,8 4,8
100 120 140 160 180 200
hmin = 100 mm Cmin = 100 mm Smin = 100 mm
Ancillaries
Code
Description
ØT mm
55762
ISO DISCO CE 140
140
Installation data Pull out values in daN Materials C12/15 concrete C16/20 - C50/60 concrete Clay bricks / calcium silicate bricks Calcium Silicate hollow blocks Vertically perforated clay bricks Porotherm 25 Lightweight aggregate concrete blocks LAC Autoclaved aerated concrete elements AAC2 Autoclaved aerated concrete elements AAC7
1 daN ≃1 kg Class A A B C C C D E E
Density Kg/dm3 ≥ 2.25 ≥ 2.30 ≥ 2.00 ≥ 1.60 ≥ 1.20 ≥ 0.80 ≥ 0.88 ≥ 0.35 ≥ 0.65
daN 50 75 75 75 60 40 60 75 90
Characteristic loading values according to ETA Recommended safety factor = 2 ETAG 014 light fixings Use category A B C D E
Building materials Normal weight concrete Solid masonry - Silicate blocks Hollow or perforated masonry Lightweight aerated concrete Autoclave aerated concrete
287
Lt = Anchor length h1 = Min. hole depth d0 = Hole diameter hef = Embedment depth Tfix = Fixture thickness P = Total depth of holes dp = Pin diameter Lnp = Pin length Ttol = Thickness of equalizing and/ or non-load-bearing layer hmin = Min. base material thickness Smin = Min. anchor spacing Cmin = Min. edge distance
fixings for insulation PANNE PANELS LLI
Vorpa ISO CE 10 MF
Light fixings for insulation panels with European Technical Assesment
Polystyrene panels
BASE MATERIALS
Silica bricks class 15
Solid clay bricks
Perforated bricks
Product group Approved for • Silica bricks class 15 • Solid bricks / Clay bricks • Perforated bricks
Use categories B-C
To fix • Polystyrene panels • Rigid insulation panels
Ideal for applications on masonry coated by heat insulating panels and rigid insulation materials
Examples of applications
Examples of applications
Product information Characteristics • Polyamide fixing with pin made of fiberglass reinforced polyamide suitable for the fixing of rigid insulation panels on perforated and compact materials. Use categories B-C Benefits • Reduced thermal transfer • Easy and quick installation, the expansion is carried out by hammering the pin inside the nylon fixing • Reduced embedment depth enables reduced drilling times • Pin made of fiberglass reinforced polyamide • Particularly indicated to fix rigid insulation materials • Product with European Technical Approval for use materials categories B-C
Installation • To be mounted aligned the wall Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • When calculating the usable length it is suggested to take into consideration eventual extra thicknesses such as glues, sealants, old plasters, etc.
288
fixings for insulation PANNE PANELS LLI
Vorpa ISO CE 10 MF
Light fixings for insulation panels with European Technical Assesment
Polystyrene panels
BASE MATERIALS
Silica bricks class 15
Solid clay bricks
Perforated bricks
Installation sequence
Wait till the sealant between the insulation panel and the base material is completely dry
Drill the base material with an appropriate drill bit
Insert the nylon fixing without pin until the washer rests again the insulation
Fix the pin by hammering gently until full expansion, i.e. when the head is leveled with washer surface
Technical data
Code
5755 5756 5757 5758 5759 5760 5761
Description
Lt d0 h1 hef mm mm mm mm
ISO CE MF 10 10/140 ISO CE MF 10 10/160 ISO CE MF 10 10/180 ISO CE MF 10 10/200 ISO CE MF 10 10/220 ISO CE MF 10 10/260 ISO CE MF 10 10/300
140 160 180 200 220 260 300
10 10 10 10 10 10 10
90 90 90 90 90 90 90
80 80 80 80 80 80 80
Tfix mm
P mm
ØT mm
dp mm
Lnp mm
b mm
S mm
Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef
Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1
60 60 60 60 60 60 60
5,3 5,3 5,3 5,3 5,3 5,3 5,3
140 160 180 200 220 260 300
85 85 85 85 85 85 85
10 10 10 10 10 10 10
hmin = 100 mm Cmin = 100 mm Smin = 100 mm
Installation data Pull out values in daN Materials Clay bricks Perforated ceramics blocks
1 daN ≃1 kg Class B C
Density Kg/dm3 ≥ 1.61 ≥ 1.17
daN 60 50
Characteristic loading values according to ETA Recommended safety factor = 2 ETAG 014 light fixings Use category A B C D E
Building materials Normal weight concrete Solid masonry - Silicate blocks Hollow or perforated masonry Lightweight aerated concrete Autoclave aerated concrete
289
Lt = Anchor length h1 = Min. hole depth d0 = Hole diameter hef = Embedment depth Tfix = Fixture thickness P = Total depth of holes dp = Pin diameter Lnp = Pin length b = Pin’s knurling length Ttol = Thickness of equalizing and/ or non-load-bearing layer hmin = Min. base material thickness Smin = Min. anchor spacing Cmin = Min. edge distance
fixings for insulation PANELS
Vorpa ISO CE 10 MC
Light fixings for insulation panels with European Technical Assesment
Polystyrene panels
BASE MATERIALS
Concrete
Aerated concrete blocks
Lightweight aggregate blocks
Solid bricks Clay bricks
Product group Approved for • Concrete • Aerated concrete • Lightweight aggregate blocks • Solid bricks / Clay bricks
Use categories A-B-C-D-E
To fix • Polystyrene panels • Rigid insulation panels
Ideal for applications on compact masonry coated by heat insulating panels and rigid insulation materials
Examples of applications
Examples of applications
Product information Characteristics • Polyamide fixing with pin made of fiberglass reinforced polyamide suitable for the fixing of rigid insulation panels on compact materials. Use categories A-B-C-D-E Benefits • Reduced thermal transfer • Easy and quick installation, the expansion is carried out by hammering the pin inside the nylon fixing • Reduced embedment depth enables reduced drilling times • Pin made of fiberglass reinforced polyamide • Product with European Technical Approval for use materials categories A-B-C-D-E
Installation • To be mounted aligned the wall Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • When calculating the usable length it is suggested to take into consideration eventual extra thicknesses such as glues, sealants, old plasters, etc.
290
fixings for insulation PANELS
Vorpa ISO CE 10 MC
Light fixings for insulation panels with European Technical Assesment
BASE MATERIALS
Concrete
Polystyrene panels
Aerated concrete blocks
Lightweight aggregate blocks
Solid bricks Clay bricks
Installation sequence
Wait till the sealant between the insulation panel and the base material is completely dry
Drill the base material with an appropriate drill bit
Insert the nylon fixing without pin until the washer rests again the insulation
Fix the pin by hammering gently until full expansion, i.e. when the head is leveled with washer surface
Technical data
Code
Description
Lt d0 mm mm
5765 5766 5767 5768 5769 5770 5771 5772 5773 5774
ISO CE MC 10 10/70 ISO CE MC 10 10/90 ISO CE MC 10 10/110 ISO CE MC 10 10/120 ISO CE MC 10 10/140 ISO CE MC 10 10/160 ISO CE MC 10 10/180 ISO CE MC 10 10/200 ISO CE MC 10 10/220 ISO CE MC 10 10/260
70 90 110 120 140 160 180 200 220 260
1) = Use categories A.B,C,D 2) = Use category E
10 10 10 10 10 10 10 10 10 10
h1 mm
hef mm
Tfix mm
P mm
≥401/≥602 ≥401/≥602 ≥401/≥602 ≥401/≥602 ≥401/≥602 ≥401/≥602 ≥401/≥602 ≥401/≥602 ≥401/≥602 ≥401/≥602
≥301/≥502 ≥301/≥502 ≥301/≥502 ≥301/≥502 ≥301/≥502 ≥301/≥502 ≥301/≥502 ≥301/≥502 ≥301/≥502 ≥301/≥502
Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef
Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1
ØT dp Lnp b mm mm mm mm
60 60 60 60 60 60 60 60 60 60
5,5 5,5 5,5 5,5 5,5 5,5 5,5 5,5 5,5 5,5
75 95 115 125 145 165 185 205 225 265
44 44 44 44 44 44 44 44 44 44
hmin = 100 mm Cmin = 100 mm Smin = 100 mm
Installation data Pull out values in daN Materials C12/15 concrete C20/25 - C50/60 concrete Clay bricks Calcium silicate solid brick Calcium silicate hollow blocks Vertically perforate clay bricks Porotherm 25 Lightweight aggregate concrete solid blocks Autoclaved aerated concrete blocks AAC2 Autoclaved aerated concrete blocks AAC7
1 daN ≃1 kg Class A A B B C C C D E E
Density Kg/dm3 ≥ 2.25 ≥ 2.30 ≥ 2.00 ≥ 2.00 ≥ 1.60 ≥ 1.20 ≥ 0.80 ≥ 0.88 ≥ 0.35 ≥ 0.65
daN 50 75 75 60 60 60 40 60 50 60
Characteristic loading values according to ETA Recommended safety factor = 2 ETAG 014 light fixings Use category A B C D E
Building materials Normal weight concrete Solid masonry - Silicate blocks Hollow or perforated masonry Lightweight aerated concrete Autoclave aerated concrete
291
Lt = Anchor length h1 = Min. hole depth d0 = Hole diameter hef = Embedment depth Tfix = Fixture thickness P = Total depth of holes dp = Pin diameter Lnp = Pin length b = Pin’s knurling length Ttol = Thickness of equalizing and/ or non-load-bearing layer hmin = Min. base material thickness Smin = Min. anchor spacing Cmin = Min. edge distance
fixings for insulation PANELS
Vorpa ISO TL
Light fixings for insulation panels with European Technical Assesment
Mineral wool lamella
Mineral wool
Polystyrene panels
BASE MATERIALS
Extruded polystyrene
Concrete
Solid bricks Clay bricks
Hollow bricks
Product group Approved for • Concrete • Solid bricks / Clay bricks • Hollow bricks ISO TL Lt ≤ 130 mm
To fix • Mineral wool lamella • Mineral wool • Polystyrene panels • Extruded polystirene
Ideal for applications on masonry covered by heat insulating panels and rigid and soft insulation materials Use categories A-B-C ISO TL Lt ≥ 150 mm
ETAG 014
A-B-C
Examples of applications
Examples of applications
Product information Characteristics • Polyethylene fixing with fiberglass reinforced nylon PA6 pin suitable to fix rigid and soft insulation materials on hollow and compact materials. Use categories A-B-C Benefits • Reduced thermal transfer granting energy saving • Easy and quick installation, the expansion is carried out by hammering the pin inside the nylon fixing • Special fiberglass reinforced polyamide pin granting more resistance to the fixing
Installation • To be mounted aligned the wall Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • When calculating the usable length it is suggested to take into consideration eventual extra thicknesses such as glues, sealants, old plasters
292
fixings for insulation PANELS
Vorpa ISO TL
Light fixings for insulation panels with European Technical Assesment
Mineral wool lamella
Mineral wool
BASE MATERIALS
Polystyrene panels
Extruded polystyrene
Concrete
Solid bricks Clay bricks
Hollow bricks
Installation sequence
Wait till the sealant between the insulation panel and the base material is completely dry
Drill the base material with an appropriate drill bit
Insert the nylon fixing without pin until the washer rests again the insulation
Fix the pin by hammering gently until full expansion, i.e. when the head is leveled with washer surface
Technical data
ISO TL Lt ≤ 130 mm Code
5744 655 656 657 658 * 740 748 752 5745 5746
ISO TL Lt ≥ 150 mm
Description
Lt mm
d0 mm
h1 mm
hef mm
Tfix mm
P mm
ØT mm
dp mm
Lnp mm
Sp mm
ISO TL ISO TL ISO TL ISO TL ISO TL ISO TL ISO TL ISO TL ISO TL ISO TL
60 70 90 110 120 130 150 180 210 240
10 10 10 10 10 10 10 10 10 10
40 40 40 40 40 40 40 40 40 40
30 30 30 30 30 30 30 30 30 30
30+Ttol 40+Ttol 60+Ttol 80+Ttol 90+Ttol 100+Ttol 120+Ttol 150+Ttol 180+Ttol 210+Ttol
Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1
53 53 53 53 53 53 58 58 58 58
5,3 5,3 5,3 5,3 5,3 5,3 5,6 5,6 5,6 5,6
68 68 68 88 108 128 148 178 210 238
2,6 2,6 2,6 2,6 2,6 2,6 2,6 2,6 2,6 2,6
10/60 10/70 10/90 10/110 10/120 10/130 10/150 10/180 10/210 10/240
*Not covered by ETA
Installation data Pull out values in daN Materials Concrete C20/25 Concrete C50/60 Solid brick/Clay brick Hollow brick
1 daN ≃1 kg Classe materiale A A B C
Density Kg/dm3 ≥ 2.30 ≥ 2.40 ≥ 2.00 ≥ 0.95
daN 39 42 47 22
Characteristic loading values according to ETA recommended safety factor = 2 ETAG 014 light fixings Use category A B C D E
Building materials Concrete Solid bricks Hollow bricks Lightweight aerated concrete Lightweight aggregate blocks
293
Lt = Anchor length h1 = Min. hole depth d0 = Hole diameter hef = Embedment depth Tfix = Fixture thickness P = Total depth of holes dp = Pin diameter Lnp = Pin length Sp = Head thickness Ttol = Thickness of equalizing and/ or non-load-bearing layer
fixings for insulation PANELS
Vorpa ISO
Light fixings for insulation panels with European Technical Assesment
Polystyrene panels
BASE MATERIALS
Extruded polystyrene
Concrete
Natural stone
Solid bricks
Product group To fix • Concrete • Natural stone • Solid bricks
Suitable for • Polystyrene panels • Extruded polystyrene • Rigid insulation panels
Ideal for applications on masonry covered by heat insulating panels and rigid and soft insulation materials Product information Installation • To be mounted aligned the wall
Characteristics • Polypropylene fixing without pin suitable to fix rigid insulation materials on compact materials. Benefits • Reduced thermal transfer • Easy and quick installation • Different lengths available grants the possibility to be used with different panels thickness • The anchoring is carried out by the thread compression inside the hole on compact material
Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • When calculating the usable length it is suggested to take into consideration eventual extra thicknesses such as glues, sealants, old plasters
Product group
Wait till the sealant between the insulation panel and the base material is completely dry
Drill the base material with an appropriate drill bit
Insert the nylon fixing without pin until the washer rests again the insulation
Technical data
Code
650 651 660 652 733 734 5736
Description
Lt mm
d0 mm
h1 mm
hef mm
Tfix mm
P mm
ØT mm
Sp mm
ISO 8/50 ISO 8/70 ISO 8/80 ISO 8/90 ISO 8/110 ISO 8/130 ISO 8/160
50 70 80 90 110 130 160
8 8 8 8 8 8 8
40 40 40 40 40 40 40
30 30 30 30 30 30 30
20-Ttol 40-Ttol 50-Ttol 60-Ttol 80-Ttol 100-Ttol 130-Ttol
Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1
35 35 35 35 35 35 35
2,6 2,6 2,6 2,6 2,6 2,6 2,6
Installation data Pull out values in daN
1 daN ≃1 kg daN 40 20 15 15
Materials Concrete C20/25 Solid brick Perforated clay blocks and partitions Italian standard hallow brick with plaster
recommended safety factor = 3 294
Lt = Anchor length h1 = Min. hole depth d0 = Hole diameter hef = Embedment depth Tfix = Fixture thickness P = Total depth of holes dp = Pin diameter Lnp = Pin length Sp = Head thickness Ttol = Thickness of equalizing and/ or non-load-bearing layer
Cladding and pipe fixings
cladding and pipe fixings
Vorpa IF-IFO
Isophonic pipe clamp for iron and Polyethylene pipes (EPDM RUBBER) M8-M10 thread
Concrete
Natural stone
Products group Suitable for • Concrete • Natural stone • Solid brick pipe clamp IF with rubber and plastic plug
pipe clamp IFO with rubber
To fix • Industrial plants • High temperature exhaust fumes • High temperature liquid discharge
Examples of applications
Installation sequence
Product information Characteristics • Isophonic pipe clamps with EPDM rubber and wall plastic plug
Benefits • Temperature range -40°C ÷ +100°C • Fire resistance DIN 4109-B2
Benefits • Two screws allows for easy adjustment to suit the outer pipe diameter • Combination nut with thread M8/M10 • The sound insulation rubber offers noise protection and avoids contact corrosion • Screws safety feature • Wall nylon plug VN with anti-rotation wings
Suggestion for use • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
296
Solid brick
cladding and pipe fixings
Vorpa IF-IFO
Isophonic pipe clamp for iron and Polyethylene pipes (EPDM RUBBER) M8-M10 thread
Concrete
Natural stone
Solid brick
Technical data
pipe clamp IFO with rubber Code
Description
nominal diameter
ExD
A-B mm
M thread
side screws
2699 2700 2701 2702 2703 2704 2705 2706 2707 2708 2709 2710 2711 2712 2713 2714 2715 2716 2718S 2718 2719
IFO 12-15 IFO 15-19 IFO 20-25 IFO 26-30 IFO 32-36 IFO 38-43 IFO 47-51 IFO 53-58 IFO 60-64 IFO 68-72 IFO 76-80 IFO 81-86 IFO 87-92 IFO 99-105 IFO 107-112 IFO 113-118 IFO 125-130 IFO 135-140 IFO 159-166 IFO 168-172 IFO 200-212
1/4 3/8 1/2 3/4 1” 1” 1/4 1” 1/2 53-58 2” 68-72 2” 1/2 81-86 3” 3” 1/2 107-112 4” 125-130 5” 159-166 6” 200-212
19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 20x2,3 20x2,3 20x2,3 20x2,3 20x2,3 20x2,3 20x2,3
9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16
M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10
M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20
Code
Description
nominal diameter
ExD
d0xLt mm
h1 mm
M x Lp mm
side screws
4699 4700 4701 4702 4703 4704 4705 4706 4707 4708 4709 4710 4711 4712 4713 4714 4715 4716 4717S 4717 4718
IF 12-15 IF 15-19 IF 20-25 IF 26-30 IF 32-36 IF 38-43 IF 47-51 IF 53-58 IF 60-64 IF 68-72 IF 76-80 IF 81-86 IF 87-92 IF 99-105 IF 107-112 IF 113-118 IF 125-130 IF 135-140 IF 159-166 IF 168-172 IF 200-212
1/4 3/8 1/2 3/4 1” 1” 1/4 1” 1/2 53-58 2” 68-72 2” 1/2 81-86 3” 3” 1/2 107-112 4” 125-130 5” 159-166 6” 200-212
19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 20x2,3 20x2,3 20x2,3 20x2,3 20x2,3 20x2,3 20x2,3
10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60
80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80
M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90
M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20
297
1” 1/2
d0 = Hole diameter h1 = Min. hole depth Lt = Anchor length Lp = Pin length ExD = Width x thickness M = Thread
Installation data 1daN ≃ 1 Kg Pipes sizes 1/4 - 3” 1/2 107 - 212
pipe clamp IF with rubber and pladtic plug
Axial recommended load 180 daN 250 daN
cladding and pipe fixings
Vorpa BRM-BRG Steel clamps for steel pipes
Concrete
Natural stone
Solid brick
Products group Characteristics • Steel clamps with nylon plug for steel pipes
To fix • Industrial plants • Plumbing and heating systems • Run water vapor systems
Suitable for • Concrete • Natural stone • Solid brick
Technical data d0 = Hole diameter h1 = Min. hole depth Lt = Anchor length Lp = Pin length ExD = Width x thickness M = Thread
BRG steel pipe clamps
Code
4472 4474 4476 4477 4478 4479 4480 4481 4482 4483 4484 4485 4486 4487 4488
Description
BRG 16-20 BRG 20-24 BRG 25-30 BRG 32-36 BRG 38-44 BRG 46-50 BRG 58-62 BRG 74-80 BRG 82-89 BRG 112-118 BRG 74-80 BRG 82-89 BRG 112-118 BRG 130-141 BRG 164-172
nominal diameter
ExD
C mm
M thread
side screws
3/8 1/2 3/4 1” 1” 1/4 1” 1/2 2” 2” 1/2 3” 4” 2” 1/2 3” 4” 5” 6”
20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5
8 8 8 8 8 8 8 8 8 8 8 8 8 8 8
M8 M8 M8 M8 M8 M8 M8 M8 M8 M8 M10 M10 M10 M10 M10
M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25
Installation data 1daN ≃ 1 Kg Pipes sizes 3/8 - 6”
BRM steel clamp with nylon plug and double threaded screw Code
1210 1211 1212 1213 1214 1215 1216 1217 1218 1219 1220 1221 1222 1223 1224
Description
BRM 16-20 BRM 20-24 BRM 25-30 BRM 32-36 BRM 38-44 BRM 46-50 BRM 58-62 BRM 74-80 BRM 82-89 BRM 112-118 BRM 74-80 BRM 82-89 BRM 112-118 BRM 130-141 BRM 164-172
nominal diameter
ExD mm
d0 x Lt mm
h1 mm
M x Lp mm
side screws
3/8 1/2 3/4 1” 1” 1/4 1” 1/2 2” 2” 1/2 3” 4” 2” 1/2 3” 4” 5” 6”
20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5
10 x 60 10 x 60 10 x 60 10 x 60 10 x 60 10 x 60 10 x 60 10 x 60 10 x 60 10 x 60 12 x 60 12 x 60 12 x 60 12 x 60 12 x 60
80 80 80 80 80 80 80 80 80 80 80 80 80 80 80
M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M10x120 M10x120 M10x120 M10x120 M10x120
M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25
298
BRM steel clamp with plastic plug and double threaded screw
Axial recommended load 250 daN
cladding and pipe fixings
Vorpa VRM - VR inox A2
A2 stainless steel clamp for iron pipes, flues, air ducts
Concrete
Natural stone
Solid brick
Products group Suitable for • Concrete • Natural stone • Solid brick
VRM inox A2 stainless steel clamp with wall plastic plug and double threaded screw
To fix • Industrial plants • Plumbing and heating systems • Run water vapor systems • coastal areas • food industries • plants on farms • sewage plants • shipyards plants
VR A2 stainless steel clamp
Examples of applications
Product information Characteristics • A2 stainless steel clamps for iron pipes, flues, air ducts and exhaust fumes outside
Suggestion for use • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
Benefits • The A2 stainless steel diameter prevents corrosive aggressions • Ideal for fixing on solid substrates
299
cladding and pipe fixings
Vorpa VRM - VR inox A2
A2 stainless steel clamp for iron pipes, flues, air ducts
Concrete
Natural stone
Solid brick
Technical data
VR A2 stainless steel clamp Code
3410 3411 3412 3413 3414 3415 3416 3417 3418 3421 3419 3420 3422 3423 3427 3424 3428 3425 3426 3429 3430
Code
3210 3211 3212 3213 3214 3215 3216 3217 3218 3222 3219 3220 3221 3223 3227 3224 3228 3225 3226
Description
VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX
Description
16-20 18-24 25-30 30-36 38-44 44-50 56-62 76-80 90-100 100-110 110-120 125-130 140-150 152-160 180 200 220 250 300 350 400
nominal diameter
ExD
M thread
side screws
3/8 1/2 3/4 1” 1” 1/4 1” 1/2 2” 2” 1/2 3” 100-110 4” 125-130 5” 6” 180 200 220 250 300 350 400
20x1,5 20x1,8 20x1,8 20x1,8 20x1,8 20x1,8 20x1,8 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 30x1,5 30x1,5 30x1,5 30x1,5 30x2 30x2
M8 M8 M8 M8 M8 M8 M8 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10
6x20 6x20 6x20 6x20 6x20 6x20 6x20 6x30 6x40 6x40 6x40 6x40 6x40 6x40 6x30 6x30 6x30 6x30 6x30 6x30 6x30
nominal diameter
ExD
VRM INOX 16-20 3/8 20x1,5 VRM INOX 18-24 1/2 20x1,8 VRM INOX 25-30 3/4 20x1,8 VRM INOX 30-36 1” 20x1,8 VRM INOX 38-44 1” 1/4 20x1,8 VRM INOX 44-50 1” 1/2 20x1,8 VRM INOX 56-62 2” 20x1,8 VRM INOX 76-80 2” 1/2 24x1,5 VRM INOX 90-100 3” 24x1,5 VRM INOX 100-110 100-110 24x1,5 VRM INOX 110-120 4” 24x1,5 VRM INOX 125-130 125-130 24x1,5 VRM INOX 140-150 5” 24x1,5 VRM INOX 152-160 6” 24x1,5 VRM INOX 180 180 24x1,5 VRM INOX 200 200 30x1,5 VRM INOX 220 220 30x1,5 VRM INOX 250 250 30x1,5 VRM INOX 300 300 30x1,5
d0 x Lt mm
h1 mm
M x Lp mm
side screws
10 x 60 10 x 60 10 x 60 10 x 60 10 x 60 10 x 60 10 x 60 12 x 60 12 x 60 12 x 60 12 x 60 12 x 60 12 x 60 12 x 60 12 x 60 12 x 60 12 x 60 12 x 60 12 x 60
80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80
M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120
6x20 6x20 6x20 6x20 6x20 6x20 6x20 6x30 6x40 6x40 6x40 6x40 6x40 6x40 6x30 6x30 6x30 6x30 6x30
300
d0 = Hole diameter h1 = Min. hole depth Lt = Anchor length Lp = Pin length ExD = Width x thickness Ø = Pipe M = Thread
Installation data 1daN ≃ 1 Kg Pipes sizes 3/8 1/2-2” 2/1/2”-300 350-400
Axial recommended load 700 daN 800 daN 700 daN 800 daN
VRM inox A2 stainless steel clamp with wall plastic plug and double threaded screw
cladding and pipe fixings
Vorpa CAV - CAV inox A2
Steel clamp with anchor for iron pipes and flues
Concrete
Natural stone
Solid brick
Products group Suitable for • Concrete • Natural stone • Solid brick
CAV steel clamp with AV anchor, welded nut and double threaded screw
CAV inox A2 stainless steel clamp with stainless steel TOP anchor, welded nut and double threaded screw
To fix • Industrial plants • Plumbing and heating systems • Run water vapor systems
Examples of applications
Installation sequence
Product information Characteristics • Steel clamp for iron pipes, flues, exhaust fumes Benefits • The A2 stainless steel material prevents corrosive aggressions • Suitable for application in food sector • Ideal for fixing on solid substrates
Suggestion for use • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
301
cladding and pipe fixings
Vorpa CAV - CAV inox A2
Steel clamp with anchor for iron pipes and flues
Concrete
Natural stone
Solid brick
Technical data
CAV steel clamp with AV anchor, welded nut and double threaded screw
Art.
451 452 453 454 450 455 456 458 457 1457 459 1459 1460 1461
Description
CAV 50 CAV 63 CAV 2” 1/2 CAV 3” CAV 100 CAV 4” CAV 125 CAV 5” CAV 6” CAV 180 CAV 200 CAV 220 CAV 250 CAV 300
nominal diameter
ExD mm
d0 x Lt mm
h1 mm
M x Lp mm
side screws
50 63 2” 1/2 3” 100 4” 125 5” 6” 180 200 220 250 300
30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5
16 x 65 16 x 65 16 x 65 16 x 65 16 x 65 16 x 65 16 x 65 16 x 65 16 x 65 16 x 65 16 x 65 16 x 65 16 x 65 16 x 65
75 75 75 75 75 75 75 75 75 75 75 75 75 75
M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110
M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25
Installation data 1daN ≃ 1 Kg Pipes sizes 50 - 300
Axial recommended load 180 daN
CAV inox A2 stainless steel clamp with stainless steel TOP anchor, welded nut and double threaded screw
Art.
3540 3541 3542 3543 3544 3545 3546 3553 3554 3555 3556 3557 3558 3559 3563 3560 3564 3561 3562 3565 3566
Description
CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX
16-20 18-24 25-30 30-36 38-44 44-50 56-62 76-80 90-100 100-110 110-120 125-130 140-150 152-160 180 200 220 250 300 350 400
nominal diameter
ExD mm
d0 x Lt mm
h1 mm
M x Lp mm
side screws
3/8 1/2 3/4 1” 1” 1/4 1” 1/2 2” 2” 1/2 3” 100-110 4” 125-130 5” 6” 180 200 220 250 300 350 400
20x1,5 20x1,8 20x1,8 20x1,8 20x1,8 20x1,8 20x1,8 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 30x1,5 30x1,5 30x1,5 30x1,5 30x2 30x2
12 x 51 12 x 51 12 x 51 12 x 51 12 x 51 12 x 51 12 x 51 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60
60 60 60 60 60 60 60 70 70 70 70 70 70 70 70 70 70 70 70 70 70
M8x100 M8x100 M8x100 M8x100 M8x100 M8x100 M8x100 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110
M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x30 M6x40 M6x40 M6x40 M6x40 M6x40 M6x40 M6x30 M6x30 M6x30 M6x30 M6x30 M6x30 M6x30
302
d0 = Hole diameter h1 = Min. hole depth Lt = Anchor length Lp = Pin length ExD = Width x thickness M = Thread
Installation data 1daN ≃ 1 Kg Pipes sizes 3/8 - 400
Axial recommended load 120 daN
cladding and pipe fixings
Vorpa CAV - P
Steel clamp with anchor for iron pipes and flues
Concrete
Products group Suitable for • Concrete • Solid brick To fix • Plumbing and heating systems
CAV steel clampa with AV anchors
Installation sequence
Product information Suggestion for use • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
Characteristics • Plumbing and heating systems
Code
Description
390 391 392 393 394 395 396
CAV-P 3/8 CAV-P 1/2 CAV-P 3/4 CAV-P 1” CAV-P 1/4 CAV-P 1/2 CAV-P 2”
nominal diameter
ExD mm
d0 x Lt mm
h1 mm
M
side screws
3/8 1/2 3/4 1” 1” 1/4 1” 1/2 2”
22 x 1,8 24 x 2,0 24 x 2,0 24 x 2,2 24 x 2,2 24 x 2,2 24 x 2,2
12 x 47 14 x 55 14 x 55 14 x 55 14 x 55 14 x 55 16 x 65
55 65 65 65 65 65 75
M6 M8 M8 M8 M8 M8 M10
M6x16 M6x16 M6x16 M6x16 M6x16 M6x16 M6x16
Installation data 1daN ≃ 1 Kg Pipes sizes 3/8 - 2”
Axial recommended load 120 daN
d0 = Hole diameter h1 = Min. hole depth Lt = Anchor length Lp = Pin length ExD = Width x thickness M = Thread
303
Solid brick
cladding and pipe fixings
Vorpa CDS GAS - VRP - CDG Steel clamps for PVC and Polyethylene pipes
Concrete
Natural stone
Solid brick
Products group To fix • Industrial plants • Plumbing and heating systems • Run water vapor systems
Suitable for • Concrete • Natural stone • Solid brick
CDS steel clamp with 1/2” welded nut
Examples of applications
VRP steel clamp with wall plastic plug and double threaded screw
CDG steel clamp with welded nut
Product information Suggestion for use • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before installation
Characteristics • Steel clamps for PVC and Polyethylene pipes
Technical data
CDS steel clamp with 1/2” welded nut ExD = Width x thickness
Code
1779 781 782 783 784 757 785 786 788 787 789 793 758 758S
Description
CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS
40 50 63 76-80 90-100 100-110 110-120 125-130 140-150 152-160 200 250 300 315
nominal diameter
ExD mm
M thread
side screws
40 50 63 76 - 2”1/2” 90 - 3” 100 - 110 4” 125 - 130 5” 6” 200 250 300 315
30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5
1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2”
M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6
304
Installation data 1daN ≃ 1 Kg Pipes sizes 40 - 315
Axial recommended load 300 daN
cladding and pipe fixings
Vorpa CDS GAS - VRP - CDG Steel clamps for PVC and Polyethylene pipes
Concrete
Natural stone
Solid brick
Technical data
CDG steel clamp with welded nut
Code
1480 481 482 483 484 476 485 486 488 487 1487 489 1489 1490 1491
Description
nominal diameter
ExD mm
M thread
side screws
40 50 63 76 90 100 110 125 140 160 180 200 220 250 300
24x2,0 24x2,2 24x2,2 24x2,2 24x2,2 24x2,2 24x2,2 24x2,2 30x2,2 30x2,2 30x2,2 30x2,2 30x2,2 30x2,2 30x2,2
M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10
M6x20 M6x20 M6x20 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25
CDG 40 CDG 50 CDG 63 CDG 76 CDG 90 CDG 100 CDG 110 CDG 125 CDG 140 CDG 160 CDG 180 CDG 200 CDG 220 CDG 250 CDG 300
d0 = Hole diameter h1 = Min. hole depth Lt = Anchor length Lp = Pin length ExD = Width x thickness M = Thread
Installation data 1daN â&#x2030;&#x192; 1 Kg Pipes sizes 40 - 300 VRP steel clamp with wall plastic plug and double threaded screw
Code
4460 461 462 463 464 460 465 466 468 467 1470 469 1471 470 471
Description
nominal diameter
ExD mm
d0x Lt mm
h1 mm
Lp mm
side screws
VRP 40 VRP 50 VRP 63 VRP 76 VRP 90 VRP 100 VRP 110 VRP 125 VRP 140 VRP 160 VRP 180 VRP 200 VRP 220 VRP 250 VRP 300
40 50 63 76 90 100 110 125 140 160 180 200 220 250 300
24x2,0 24x2,2 24x2,2 24x2,2 24x2,2 24x2,2 24x2,2 24x2,2 30x2,2 30x2,2 30x2,2 30x2,2 30x2,2 30x2,2 30x2,2
12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60
75 75 75 75 75 75 75 75 75 75 75 75 75 75 75
M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120
M6x20 M6x20 M6x20 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25
305
Axial recommended load 180 daN
cladding and pipe fixings
Vorpa CFI inox A2
A2 stainless steel clamps for flues and air ducts
Concrete
Solid brick
Perforated brick
Aerated poroton
Perforated cement
Products group Suitable for • Concrete • Solid brick • Perforated brick • Aerated poroton • Perforated cement
To fix • Flues • Air ducts • Industrial plants • Run water vapor system • Exhaust fumes • Smoking pipes
Examples of applications
d0 h1 Lt Lp
Product information
= Hole diameter = Min. hole depth = Anchor length = Pin length
Suggestion for use • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation
Characteristics • A2 stainless steel clamps for flues and air ducts Benefits • The A2 stainless steel material prevents corrosive aggressions • Suitable for application in food sector • Ideal for fixing on solid substrates Technical data CFZ collare in acciaio A2 con tassello e vite di congiunzione Code
2771 2772 2773 2774 2775 2776 2777 2778 2779 2780 2781
Description
nominal diameter
ExD mm
d0 x Lt mm
CFI INOX 76-80 CFI INOX 100 CFI INOX 110-120 CFI INOX 125-130 CFI INOX 140-150 CFI INOX 160 CFI INOX 180 CFI INOX 200 CFI INOX 220 CFI INOX 250 CFI INOX 300
76-80 100 110-120 125-130 140-150 160 180 200 220 250 300
24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 30x1,5 30x1,5 30x1,5 30x1,5 30x1,5
10 x 80 10 x 80 10 x 80 10 x 80 10 x 80 10 x 80 12 x 74 12 x 74 12 x 74 12 x 74 12 x 74
Li = Axial spacing ExD = Width x thickness Ø = Pipes M = Thread
h1 mm
85 85 85 85 85 85 85 85 85 85 85
306
M x Lp mm
Li mm
side screws
M 8x200 M 8x200 M 8x200 M 8x200 M 8x200 M 8x200 M 10x180 M 10x180 M 10x180 M 10x180 M 10x180
158 170 175 182 190 200 210 220 230 245 270
M6x30 M6x30 M6x40 M6x40 M6x40 M6x30 M6x30 M6x30 M6x30 M6x30 M6x30
cladding and pipe fixings
Vorpa CFZ
White or black plastic-coated steel clamp for flues, air ducts, smoking pipes
Concrete
Solid brick
Perforated brick
Poroton
Products group Suitable for • Concrete • Solid brick • Perforated brick • Poroton • Perforated cement
To fix • Air ducts • Flues • Smoking pipes
Examples of applications
d0 h1 Lt Lp
ExD = Width x thickness Ø = Pipe Li = Axial spacing M = Thread
= Hole diameter = Min. hole depth = Anchor length = Pin length
Product information Characteristics • White or black plastic-coated steel clamp for flues, air ducts, smoking pipes Technical data White plastic-coated Code
2406 800 794 2485 2486 2488 2487
Description
nominal diameter
ExD mm
d0 x Lt mm
h1 mm
M x Lp mm
Li mm
side screws
CFZ 60 CFZ 76-80 CFZ 100 CFZ 110-120 CFZ 125-130 CFZ 140-150 CFZ 160
60 76-80 100 110-120 125-130 140-150 160
24x2,2 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5
10 x 80 10 x 80 10 x 80 10 x 80 10 x 80 10 x 80 10 x 80
85 85 85 85 85 85 85
M 8x200 M 8x200 M 8x200 M 8x200 M 8x200 M 8x200 M 8x200
150 158 170 175 182 190 200
M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25
nominal diameter
ExD mm
d0 x Lt mm
h1 mm
M x Lp mm
Li mm
side screws
76-80 100
24x1,5 24x1,5
10 x 80 10 x 80
M 8x200 M 8x200
158 170
M6x25 M6x25
Black plastic-coated Code
Description
800N CFZ 76-80 794N CFZ 100
85 85
307
Perforated cement
cladding and pipe fixings
Vorpa CP
Light steel clamps for drain pipes
Concrete
Natural stone
Products group To fix • Drain pipes
Suitable for • Concrete • Natural stone • Solid brick Rounded clamp
Squared clamp
Examples of applications
Product information Characteristics • Double threaded M8 screws and nylon plug VN 10x60 • 3 different versions available
Technical data CP rounded clamp with wall plastic plug VN and double threaded screw
Code
494 491 492 493 495 496 498 499
Description
Lt mm
d0 mm
h1 mm
Lp mm
side screws
Ø mm
ExD mm
CP zincplated Ø 60 CP zincplated Ø 80 CP zincplated Ø 100 CP zincplated Ø 120 CP dark brown Ø 80 CP dark brown Ø 100 CP copper Ø 80 CP copper Ø 100
60 60 60 60 60 60 60 60
10 10 10 10 10 10 10 10
70 70 70 70 70 70 70 70
M 8x75 M 8x75 M 8x75 M 8x75 M 8x75 M 8x75 M 8x75 M 8x75
M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20
60 80 100 120 80 100 80 100
28x1,5 28x1,5 28x1,5 28x1,5 28x1,5 28x1,5 28x1,5 28x1,5
CP squared clamp with wall nylon plug VN and double threaded screw
Code
501 502 505 506 508 509
Description
Lt mm
d0 mm
h1 mm
Lp mm
side screws
Ø mm
ExD mm
CP zincplated Ø 80x80 CP zincplated Ø 100x100 CP dark brown Ø 80x80 CP dark brown Ø 100x100 CP copper Ø 80x80 CP copper Ø 100x100
60 60 60 60 60 60
10 10 10 10 10 10
70 70 70 70 70 70
M 8x75 M 8x75 M 8x75 M 8x75 M 8x75 M 8x75
M6x20 M6x20 M6x20 M6x20 M6x20 M6x20
80x80 100x100 80x80 100x100 80x80 100x100
28x1,5 28x1,5 28x1,5 28x1,5 28x1,5 28x1,5
308
d0 = Hole diameter h1 = Min. hole depth Lt = Anchor length Lp = Pin length ExD = Width x thickness Ø = Pipe Øp = Pin diameter
Solid brick
cladding and pipe fixings
Vorpa VCR
Light copper clamps for pipes
Concrete
Natural stone
Solid brick
Technical data
VCR-VCR T light copper clamp with plastic wall plug VN and double threaded copper screw
VCR copper light clamp with pre-assembled side screw
VN R plastic wall plug VN with double threaded copper screw
Product information Characteristics • Light copper clamps Ø 10 to Ø 54 mm with plastic wall plug VN 6 x30 threaded copper screw • Pre-assembled side screws
Suggestion for use • Respect the installation data • Clean the hole before the installation
Technical data VCR T light copper clamp with plastic wall plug VN and double threaded copper screw Code
5400 5401 5402 5403 5404 5405 5406 5407 5409 5408 5410 5411
Description
VCR T 10 VCR T 12 VCR T 14 VCR T 16 VCR T 18 VCR T 22 VCR T 28 VCR T 32 VCR T 35 VCR T 38 VCR T 42 VCR T 54
Lt mm
d0 mm
h1 mm
Øv xLv mm
side screws
Ø mm
ExD lower portion (mm)
ExD upper portion (mm)
30 30 30 30 30 30 30 30 30 30 30 30
6 6 6 6 6 6 6 6 6 6 6 6
40 40 40 40 40 40 40 40 40 40 40 40
6x30 6x30 6x30 6x30 6x30 6x30 6x30 6x30 6x30 6x30 6x30 6x30
M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5
10 12 14 16 3/8” - 18 1/2” - 22 3/4” - 28 1” - 32 35 38 42 54
15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 16x1,2 16x1,2
10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 12x0,9 12x0,9
VCR copper light clamp with pre-assembled side screw Code
4400 4401 4402 4403 4404 4405 4406 4407 4409 4408 4410 4411
Description
VCR 10 VCR 12 VCR 14 VCR 16 VCR 18 VCR 22 VCR 28 VCR 32 VCR 35 VCR 38 VCR 42 VCR 54
side screws
Ø mm
ExD lower semicollar (mm)
ExD upper semicollar (mm)
M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5
10 12 14 16 3/8” - 18 1/2” - 22 3/4” - 28 1” - 32 35 38 42 54
15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 16x1,2 16x1,2
10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 12x0,9 12x0,9
d0 = Hole diameter h1 = Min. hole depth Lt = Plug length Lv = Screw length ExD = Width x thickness Ø = Pipe
VN R plastic wall plug VN with double threaded copper screw Description
Lt mm
d0 mm
h1 mm
Øv xLv mm
metric threaded
4768 VN R 6x30
30
6
40
6x30
M6
Code
309
d0 = Hole diameter h1 = Min. hole depth Lt = Plug length Lv = Screw length ExD = Width x thickness Øt = Pipes Øv = Screw diameter
cladding and pipe fixings
Vorpa CT
Steel clamp for light pipes
Concrete
Natural stone
Products group To fix • Light steel pipes
Suitable for • Concrete • Natural stone • Solid brick
Product information Characteristics • Stell clamps for light pipes Ø 10 to Ø 50mm with nylon wall plug VN V 8x40 and double threaded screw • Pre-assembled side screws
Suggestion for use • Respect the installation data • Clean the hole before the installation
Technical data
Code
1400 1401 1402 1403 1404 1405 1406 1407 1408 1409 1410 1415 1411 1412 1413 1414
Description
CT 10 CT 12 CT 14 CT 16 CT 18 CT 20 CT 22 CT 24 CT 26 CT 28 CT 32 CT 35 CT 38 CT 42 CT 48 CT 50
side screws
Øt mm
ExD lower semicollar (mm)
ExD upper semicollar (mm)
M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5
10 12 14 16 18 20 22 24 26 28 32 35 38 42 48 50
15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 16x1,2 16x1,2 16x1,2
10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 12x0,9 12x0,9 12x0,9
Lt = Plug length Lv = Screw length ExD = Width x thickness Øt = Pipes Øv = Screw diameter
Accessories
VN V plastic wall plug VN with double threaded screw Description
Lt mm
d0 mm
h1 mm
Øv xLv mm
metric thread
768 VN V 8x40
40
8
50
6x40
M6
Code
310
Solid brick
cladding and pipe fixings
Vorpa KPO
Plastic clip for fixing metric insulation pipes Products group To fix • Metric insulation pipes cable
Suitable for • Nylon plug Ø6
Examples of applications
Product information Characteristics • Cables: Ø mini 16 - Ø maxi 50 • Raw Material: Polypropylen • Burning properties: according to IEC 60695-2-12 (GWFI): 650°C • Colour: Grey, RAL 7035 • Installation temperature: -5°C / +35°C • Working temperature: -30°C / +55°C
Benefit • Plastic clip for fixing or protecting rigid, metric insulating pipes in electrical installations, on vertical or horizontal surfaces (from Ø 16 to 50 mm) • Can be installed with a light-weight anchor • Rounded shape to facilitate pipe accomodiation • Elongated hole for adjusting wall fixings • Side hook for connecting other pipe clamps in series • Guide for laying in raceways • Allows a fast, economic and precise fixing of plastic pipes in the electrical applications
Installation sequence
Technical data
Code
2190 2191 2192 2193 2194 2195
Description
Ø pipe mm
Dc mm
X mm
C mm
width mm
KPO 16 KPO 20 KPO 25 KPO 32 KPO 40 KPO 50
16 20 25 32 40 50
15 19 24 30 38 48
10,5 12,5 15,0 20,0 25,0 32,5
17,5 19,5 22,0 26,5 30,4 35,4
16 16 16 16 16 16
axial load axial load retention daN insertion daN
8 9 9 6 7 5
6 7 6 9 7 7
311
KPO A (mm) B (mm) D (mm) F (mm G (mm) H (mm) I (mm) L (mm)
D16 15 26,9 22 16,1 4 9,1 10,4 27,1
D20 19 29,3 28,1 16,1 4 9,1 10,9 32,8
D25 24 35,55 34,2 16,1 4 9,1 11,1 39,1
D32 30 43,5 41,2 16,1 4 9,1 10,7 46,2
D40 38 49,7 48,1 16,1 4 9,1 10,4 53,1
D50 48 58,5 59,2 16,1 4 9,1 10,4 64,4
cladding and pipe fixings
Vorpa KP
Nylon clip for pipe and cable Products group Suitable for • nylon plug Ø6
Examples of applications
To fix • Metric insulation pipes cable
Product information Characteristics • Cables: Ø mini 8 - Ø maxi 60 • Raw Material: Polyamid 6 • Burning properties: according to IEC 60695-2-12 (GWFI): 650°C • Colour: Grey, RAL 7035 • Installation temperature: -5°C / +40°C • Working temperature: -30°C / +65°C
Benefit • Plastic clip with an upper part suitable for pipes saddle • Can be installed with a light-weight anchor • Made of polypropylene colour Grey RAL 7035 • Flammability rating: UL 94-HB • Simple interlocking of the upper part by pressure • The pressure of the inside flexible tabs fix the pipes in position, leaving room for longitudinal movements • A side hook for connecting other pipe saddles in series • Available in many diameters and packaging (box or industrial carton)
Installation sequence
Technical data
Code
1190 1191 1192 1193 1194 1195 1196 1197
Description
KP 8 KP 10 KP 16 KP 20 KP 25 KP 32 KP 40 KP 50
Ø mim mm
Ø max mm
resistance of the top part opening
4 8 12 16 20 25 32 40
8 12 16 23 25 32 40 60
10 10 23 20 25 31 40 50
KP A (mm) A1 (mm) B (mm) C (mm D (mm) E (mm) F (mm) G (mm) H (mm)
312
20 16 10 8 8,05 10,6 14,25 16,3 11,8 15,3 17,45 9,7 16,85 16,8 16,25 15,75 18,6 22,45 11,75 12 16,7 21,8 26,75 31 4 4,9 4,9 4,9 17,2 17,2 16,9 16,65 3,9 3,9 4 4 18,95 24,05 29,2 33,4
25 18,2 19,7 15,9 25,3 34,7 4,85 17 3,85 37,2
32 23,8 25,15 15,6 34,6 45,6 4,8 17 4 47,85
50 40 27,8 35,2 37 28,8 15,45 15,45 44,15 57,3 55,1 69,35 4,9 4,85 16,95 17,15 4,1 4,1 57,35 71,6
cladding and pipe fixings
Vorpa TC
Nylon clip with plug and screw
Concrete
Natural stone
Solid brick
Hollow brick
Perforated brick
Perforated cement
Products group
TC1
Suitable for • Concrete • Natural stone • Solid brick • Hollow brick • Perforated brick • Perforated cement
TC2
To fix • Metric insulation pipes • Cable
Product information Characteristics • Nylon clip with plug and screw • Double version available
Suggestion for use • The use of plastic anchors is not recommended for permanent suspended loading applications above 40°C
Benefit • Installation temperature: +5°C / +40°C • Working temperature: -40°C / +40°C (max +80°C fot short period)
Examples of applications
Installation sequence
Technical data
TC1 single nylon clip
Code
1090 1091 1092 2868 1093 1094 1095 1096 1097 1098 1100
Description
dv xLv mm
d0 mm
hmin mm
h1 mm
hef mm
Ø mm
TC1 10 TC1 12 TC1 14 TC1 15 TC1 16 TC1 18 TC1 20 TC1 22 TC1 24 TC1 26 TC1 28
3,5x35 3,5x35 4x45 4x45 4x45 4,5x50 4,5x50 4,5x50 6x60 6x60 6x60
5 5 6 6 6 8 8 8 10 10 10
30 30 50 50 50 60 60 60 80 80 80
30 30 35 35 35 45 45 45 50 50 50
20 20 25 25 25 30 30 30 40 40 40
10 12 14 15 16 18 20 22 24 26 28
313
d0 = Hole diameter h1 = Min. hole depth Lt = Plug length Lv = Screw length Ø = Pipes hef = Effective embedment depth dv = Screw diameter hmin = Minimum thickness of the fixture
cladding and pipe fixings
Vorpa TC
Nylon clip with plug and screw
Concrete
Natural stone
Solid brick
Hollow brick
Perforated brick
Perforated cement
Installation sequence
Technical data
TC2 double nylon clip
Code
2090 2091 2092 2867 2093 2094 2095 2096 2097 2100
Description
dv xLv mm
d0 mm
hmin mm
h1 mm
hef mm
Ø mm
TC2 10 TC2 12 TC2 14 TC2 15 TC2 16 TC2 18 TC2 20 TC2 22 TC2 24 TC2 28
4,5x50 4,5x50 4,5x50 4,5x50 4,5x50 6x60 6x60 6x60 6x60 6x60
8 8 8 8 8 10 10 10 10 10
60 60 60 60 60 80 80 80 80 80
60 60 60 60 60 70 70 70 70 70
30 30 30 30 30 40 40 40 40 40
10 12 14 15 16 18 20 22 24 28
d0 = Hole diameter h1 = Min. hole depth Lt = Plug length Lv = Screw length Ø = Pipes hef = Effective embedment depth dv = Screw diameter hmin = Minimum thickness of the fixture
Installation data Pull-out values in daN
Perforated brick Double brick UNI Concrete C20/25
1 daN ≃1 kg TC1 10÷12 30 42 54
TC1 14÷16 48 78 90
TC1 18÷22 72 84 96
TC1 24÷28 96 120 180
ATTENTION: an appropriate safety factor ≥ 6 should be applied on these values.
314
TC2 10÷16 72 84 96
TC2 18÷28 96 120 180
cladding and pipe fixings
Vorpa TC
Nylon clip with plug and screw
Concrete
Natural stone
Solid brick
Hollow brick
Perforated brick
Perforated cement
Products group Suitable for • Concrete • Natural stone • Solid brick • Hollow brick • Perforated brick • Perforated cement
To fix • Metric insulation pipes • Cable
EN 50146 conformity
Product information Characteristics • Nylon cable tie for plastic and metal pipe Benefit • Cables: Ø min 16 - Ø maxi 63 • Raw Material: Polyammide • Burning properties: according to IEC 60695-2-12 (GWFI): 650°C • Colour: Grey, RAL 7035 • Installation temperature: -5°C/+35°C • Working temperature: -40°C/+70°C • Flammability rating: UL 94-HB • Plastic cable for fixing or protecting rigid, metric insulating pipes in electrical installations, on vertical or horizontal surfaces (from Ø 16 to 63 mm) • Cam be installed with a light-weight anchor
Suggestion for use • The use of plastic anchors is not recommended for permanent suspended loading applications Examples of applications
Installation sequence
Technical data C A D B
Code
Description
2400 TC for Ø 16 - Ø 32 pipes 2401 TC for Ø 40 - Ø 63 pipes
d0 = hole diameter for screw
d0 mm
A mm
B mm
C mm
D mm
Working temperature
Installation temperature
Resistance of the cable tie opening
6 6
17.6 17.6
24.5 40.5
180 280
5.9 5.9
-40°C / +70°C -40°C / +70°C
-5°C / +35°C -5°C / +35°C
36 36
315
cladding and pipe fixings
Vorpa FZ CABLE TIE Products group suitable to fix • electrical installations • industrial wiring • automotive • panel buildings • special applications
natural cable tie
black cable tie
Product information Characteristics Material: Humidity absorption:
Polyamide 6.6 2,7% (50% relative humidity)
• Working temperature • Tightening temperature • Max admissable point • Melting temperature
-40°C ÷ 85°C -10°C ÷ 60°C +110°C for short time +256°C
Limit Oxygen Index (LOI): Flammability rating:
27% UL 94 class V2
Characteristics • High resistance to bases, oils, greases, oil derivatives • Limited resistance to acids • Not resistant to phenols and to chloride solvents • Halogen-free resins • UV resistance (black color) Benefits • Smooth rounded edges make them easier to be handled and safer to be installed • Bent rounded tip allows easier insertion through the head of the cables ties • Low friction coefficient of the material
Tested according to EN 50146 Installation sequence
Insert the tip of the tie.
Tighten manually the tie till complete fixing of the cables.
Avoid sharp bending of the tie: it will not improve the fixing strength.
Cut the exceeding part of the tie, with a few mm of safety length.
Technical data Code
Description natural cable tie
Code
Description black cable tie
00010 00011 00012 00013 00014 00015 00016
FZ N FZ N FZ N FZ N FZ N FZ N FZ N
00001 00002 00003 00004 00005 00006 00007
FZ B FZ B FZ B FZ B FZ B FZ B FZ B
100/2,5 160/2,5 200/2,5 140/3,5 280/3,5 360/3,5 280/4,5
Ø bundle mm
tensile strenght kg
21 40 52 35 80 103 79
8 8 8 13 13 13 22
100/2,5 160/2,5 200/2,5 140/3,5 280/3,5 360/3,5 280/4,5
316
cladding and pipe fixings
Vorpa CLIPS
Clips with single or double hole Products group
SFT 1 zincplated single hole clip hotdipped galvanized version available
SL 1 zincplated light single hole clip
SFT 2 zincplated double hole clip
SFT 2 with antirotation protuberance
SL 2 zincplated light double hole clip
Product information To fix • Rigid conduits / cable • Tubes for installations • Signs for road-signs Installation sequence
Technical data SFT 1 zincplated single hole clip (ideal for plumbing) Code
338 339 340 341 342 343 344 345 346 347
Description
A mm
B mm
C mm
E mm
F mm
Øt mm
SFT1 10 SFT1 12 SFT1 14 SFT1 3/8” SFT1 1/2” SFT1 3/4” SFT1 1” SFT1 1”1/4 SFT1 1”1/2 SFT1 2”
14 16 18 20 22 23 24 24 25 25
1,2 1,2 1,5 1,8 1,8 2,0 2,0 2,2 2,2 2,2
5 5 5 6 6 6 8,5 8,5 8,5 8,5
8 8 8 10 10 10 11 11 11 11
18 20 20 25 28 30 35 40 45 50
10 12 14 3/8” 1/2” 3/4” 1” 1”1/4 1”1/2 2”
SFZ hotdipped galvanizzed single hole clip (ideal for light and telephone poles) Code
Description
A mm
B mm
C mm
E mm
F mm
Øt mm
341ZC 342ZC 343ZC 344ZC 345ZC 346ZC 347ZC
SFZ 3/8” SFZ 1/2” SFZ 3/4” SFZ 1” SFZ 1”1/4 SFZ 1”1/2 SFZ 2”
20 22 23 24 24 25 25
1,8 1,8 2,0 2,0 2,2 2,2 2,2
6 6 6 8 8 8 8
10 10 10 11 11 11 11
25 28 30 35 40 45 50
3/8” 1/2” 3/4” 1” 1”1/4 1”1/2 2”
317
A = Width B = Thickness CxE = Anchor length F = Distance Øt = Pipes
cladding and pipe fixings
Vorpa CLIPS
Clips with single or double hole Technical data SL 1 zincplated light single hole clip (ideal for electrical rigid colduits) Code
3338 3339 3340 3341 3342 3343 3344 3345 3346 3347 3348
Description
A mm
B mm
C mm
E mm
F mm
Øt mm
SL1 7 SL1 10 SL1 12 SL1 16 SL1 20 SL1 22 SL1 26 SL1 28 SL1 32 SL1 38 SL1 50
10 14 14 14 14 14 14 14 15 15 15
0,9 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,8 1,8 1,8
4,5 6,5 6,5 6,5 6,5 6,5 6,5 6,5 6,5 6,5 6,5
6,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5
14 17 18 20 22 24 26 28 33 46 53
7-8 10-11 12-13 16-17 19-20 21-22 25-26 28-30 31-32 38-40 50
SFT 2 zincplated double hole clip (ideal for plumbing) Code
351 352 353 354 355 356 357 358
Description
A mm
B mm
C mm
E mm
F mm
Øt mm
SFT2 3/8” SFT2 1”1/2 SFT2 3/4” SFT2 1” SFT2 1”1/4 SFT2 1”1/2 SFT2 2” SFT2 2”1/2
15 22 23 23 24 24 25 30
1,5 2,0 2,0 2,2 2,2 2,2 2,2 2,2
6 8 8 8 8,5 8,5 8,5 Ø10
10 10 10 10 11 11 11 Ø10
50 56 60 70 80 90 100 130
3/8” 1/2” 3/4” 1” 1”1/4 1”1/2 2” 2”1/2
SL 2 zincplated light double hole clip (ideal for electrical rigid conduits) Code
3352 3353 3354 3355 3356 3357 3358 3359 3360 3361
Description
A mm
B mm
C mm
E mm
F mm
Øt mm
SL2 10 SL2 13 SL2 16 SL2 19 SL2 22 SL2 26 SL2 28 SL2 32 SL2 38 SL2 50
10 10 12 12 14 14 14 14 14 14
0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9
5 5 5 5 6,5 6,5 6,5 6,5 6,5 6,5
Ø5 Ø5 6,5 6,5 8,5 8,5 8,5 10 10 10
31 32 34 38 41 47 50 54 61 80
10 13 16 19 22 26 28 32 38 50
318
A = Width B = Thickness CxE = Anchor length F = Distance Øt = Pipes
cladding and pipe fixings
Vorpa CLIPS
Clips with single or double hole dati tecnici
SFT 2 with antirotation protuberance for traffic poles
Code
Description
357S SPS2 60
A mm
B mm
C mm
E mm
F mm
Øt mm
25
2,2
Ø 8,5
11
100
Ø 60
SFT 2 with antirotation protuberance for traffic poles
Description
360 SPS3 60
A mm
B mm
C mm
F mm
Øt mm
20
3,0
Ø9
102
Ø 60 90°
Øt
Code
10 125
F E
A
A B C F Øt
319
= Width = Thickness = Hole = Distance = Pipes
**
cladding and pipe fixings
Vorpa BANDING IN ROLL Banding for pipe applications Products group To fix • Flues • Traffic signs • Vertical PVC downpipes
Code 52361
Code 52362
Product information
Examples of applications
Characteristics • Zincplated and cloth banding for pipe applications Benefit • Ideal for vertical PVC downpipes, parallel conducts and suspended installations • Easy installation • Available in ondulated zincplated version and in resistant cloth Suggestion for use • Always check load bearing capacity • Respect the installation data
Lenght mm
Ø hole mm
A mm
B mm
C mm
52361 Zincplated banding 12 421 Zincplated banding 17 419 A2 S.S. 17 banding
10 10 10
5 7 7
12 17 17
0,7 0,7 0,8
9 20 20
52368 Cloth 15 banding
15
15
1
Code
Description
Ancillaries
Code
Description
52366 Steel nail 18 52367 Steel nail 22 52365 Striker
nail Ø mm
E mm
L mm
4,2 4,2
26 30
18 22
320
cladding and pipe fixings
Vorpa U-BOLT Heavy duty pipe clamp Products group Materials • S275JR EN 10025 (Fe 430) Accessories • No. 2 hexagonal nuts UNI 5588 class 8 • No. 2 plain washers UNI 6592 class 100HV white zinc-plated
Characteristics • Special U-shaped threaded screw. Suitable for clamping circular section elements of various sizes, from small diameter tubes to big pipes. • Made out of coated steel. • ISO metric thread. • Accessories for assembling included. • In line with 2002/95/CE (RoHS) regulations.
Technical data
Code
5200 5201 5202 5203 5204 5205 5206 5207 5208 5209 5210 5211 5212 5213
Description
h mm
b mm
e mm
a mm
d1 mm
d2 mm
d3 mm
U-BOLT 18 U-BOLT 22 U-BOLT 28 U-BOLT 35 U-BOLT 40 U-BOLT 48 U-BOLT 60 U-BOLT 75 U-BOLT 90 U-BOLT 100 U-BOLT 115 U-BOLT 140 U-BOLT 168 U-BOLT 220
37 43 47 55 63 73 85 101 113 130 142 169 202 254
19 25 25 25 25 30 30 30 30 35 35 35 45 45
24 28 33 40 49 57 69 85 97 110 123 148 178 230
18 22 27 34 43 49 61 77 89 102 115 140 168 220
3/8” 1/2” 3/4” 1” 1”1/4” 1”1/2” 2” 2”1/2” 3” 3”1/2” 4” 5” 6” 8”
5,3 5,3 5,3 5,3 5,3 7,1 7,1 7,1 7,1 7,1 7,1 7,1 8,9 8,9
M6 M6 M6 M6 M6 M8 M8 M8 M8 M8 M8 M8 M10 M10
321
h b a e d1 d2 d3
= pipe clamp height = metric thread = pipe clamp width = distance = for pipe = diameter = thread
cladding and pipe fixings
Vorpa VNS
Fixings for boilers, water heaters and flush tanks
Concrete
Natural stone
Products group Suitable for • Concrete • Natural stone • Solid brick
To fix • Boilers • Flush tanks Examples of applications
Installation sequence
Product information Characteristics • Steel hook with nylon plug to fix boilers and flush tanks
Suggestion for use • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation
Technical data
Description
Lt mm
d0 mm
h1 mm
Lp mm
Øp mm
397 VNS 8/65 398 VNS 10/75 417 VNS 10/95
60 60 60
10 12 12
75 75 75
70 75 95
8 10 10
Code
Installation data Recommended values in daN Materials Concrete C20/25 Double brick Uni with plaster
1 daN ≃1 kg VNS 8 Ø10 60 45
VNS 10 Ø12 105 75
322
d0 h 1 L t Lp Øp
= Hole diameter = Min. hole depth = Plug length = Hook length = Hook diameter
Solid brick
cladding and pipe fixings
Vorpa TV
Fixing set for wall toilets and built-in toilets
Concrete
Natural stone
Solid brick
Perforated brick
Products group TV N fixing set for wall toilets
TV NL fixing set for built-in toilets
Suitable for • Concrete • Natural stone • Solid brick • Perforated brick • Perforated cement Examples of applications
TV M fixing set for wall toilets
TV ML fixing set for built-in toilets
Characteristics • TV N: nylon bushing and steel nut with wall plug VN • TV NL: 2 flanged threaded nylon nuts with wall plug VN • TV M: nylon bushing and steel nut with wall plug VH • TV ML: 2 flanged threaded nylon nuts with wall plug VH Suggestion for use • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation
Installation sequence TV N - TV M
Clean the hole before the installation TV NL - TV ML
Clean the hole before the installation 323
To fix • Wash basins • Built-in toilets • Urinal
Perforated cement
cladding and pipe fixings
Vorpa TV
Fixing set for wall toilets and built-in toilets
Concrete
Natural stone
Solid brick
Perforated brick
Technical data
TV N fixing set for wall toilets
Code
Description
Lt mm
d0 mm
h1 mm
Lp mm
Øp mm
Tfix mm
205 206 207 *1206
TVN 8/90 TVN 10/120 TVN 10/140 TVN 10/120 INOX A2
60 60 60 60
10 12 12 12
75 75 75 75
90 120 140 120
M8 M10 M10 M10
25 45 65 45
* A2 stainless steel Recommended load in daN
d0 h1 Lt Lp Øp Tfix
= Hole diameter = Min. hole depth = Plug length = Hook length = Hook diameter = Fixture thickness
d0 h1 Lt Lp Øp Tfix
= Hole diameter = Min. hole depth = Plug length = Hook length = Hook diameter = Fixture thickness
1 daN ≃1 kg TVN 8/90 Ø10 60 50
Materials Concrete C20/25 Double brick UNI with plaster
TVN 10/120 Ø12 105 80
TVN 10/140 Ø12 100 70
TV NL fixing set for built-in toilets
Code
Description
1208 TV NL 10/180
Lt mm
d0 mm
h1 mm
Lp mm
Øp mm
Tfix mm
60
12
75
180
M10
105
Recommended load in daN Materials Concrete C20/25 Double brick UNI with plaster
1 daN ≃1 kg TV NL 10/180 Ø12 90 60
324
Perforated cement
cladding and pipe fixings
Vorpa TV
Fixing set for wall toilets and built-in toilets
Concrete
Natural stone
Solid brick
Perforated brick
Technical data
TV M fixing set for wall toilets
Code
Description
231 TV M 10/145 *2231 TV M 10/145 INOX A2
Lt mm
d0 mm
h1 mm
Lp mm
Øp mm
Tfix mm
70 70
14 14
85 85
145 145
M10 M10
45 45
* A2 stainless steel Recommended load in daN
1 daN ≃1 kg
d0 h1 Lt Lp Øp Tfix
= Hole diameter = Min. hole depth = Plug length = Hook length = Hook diameter = Fixture thickness
d0 h1 Lt Lp Øp Tfix
= Hole diameter = Min. hole depth = Plug length = Hook length = Hook diameter = Fixture thickness
TV M 10/145 Ø14 120 90
Materials Concrete C20/25 Double brick UNI with plaster
TV ML fixing set for built-in toilets
Code
Description
232 TV M L10/145 *2232 TV M L10/145 INOX A2
Lt mm
d0 mm
h1 mm
Lp mm
Tfix mm
70 70
14 14
85 85
180 180
85 85
* A2 stainless steel Recommended load in daN Materials Concrete C20/25 Double brick UNI with plaster
1 daN ≃1 kg TV ML 10/80 Ø14 80 40
325
Perforated cement
cladding and pipe fixings
Vorpa TV NC
Fixing set for wall flush tanks
Concrete
Natural stone
Products group Suitable for • Concrete • Natural stone • Solid brick
To fix • Wall flush tanks
Examples of applications
Installation sequence
Product information Characteristics • Heavy steel hook with plastic plug, to fix wall flush tanks, the white sleeve prevents contact between the screw and the ceramics
Suggestion for use • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation
Technical data
Code
Description
2440 TV NC 8/90
Lt mm
d0 mm
h1 mm
Lp mm
Øp mm
Tfix mm
60
10
75
90
8
35
Installation data Recommended values in daN Materials Concrete C20/25 Double brick UNI with plaster
1 daN ≃1 kg TV NC Ø10 60 50
326
d0 h1 Lt Lp Øp Tfix
= Hole diameter = Min. hole depth = Plug length = Hook length = Hook diameter = Fixture thickness
Solid brick
cladding and pipe fixings
Vorpa TV NO - NK
Fixing set for free-standing toilets and bidets Technical data Sanitary fixing set for toilets and bidets with vertical holes
TV NO brass Code
Description
247 TV NO 10/80 2247 TV NO 10/80 INOX A2
TV NO stainless steel A2 Lt mm
d0 mm
h1 mm
Lp mm
Øp mm
Set content
50 50
10 10
75 75
80 80
6 6
4 plugs 10x50 4 screws 6x80 4 white sleeves 4 nuts
Installation sequence TV NO
Respect the installation data, clean the hole before the installation.
Description
2248 TV NK 10/50
= Hole diameter = Min. hole depth = Plug length = Hook length = Hook diameter = Screw diameter = Screw length
The pronounced rim prevents contact between the screw and ceramics.
Sanitary fixing set for toilets and bidets with side holes
Code
d0 h 1 L t Lp Øp Ø v Lv
Lt mm
d0 mm
h1 mm
Lv mm
Øv mm
Set content
50
10
75
60
7
2 plugs 10x50 - 2 hexagonal screws 7x65 2 nylon angles L - 2 washer Ø8 2 cover caps Ø18 2 nylon sleeves Ø15 2 screws Ø4,5x45
Installation sequence TV NK
Respect the installation data, clean the hole before the installation.
327
cladding and pipe fixings
Vorpa TVH
Fixing set for water heathers
Concrete
Natural stone
Solid brick
Perforated brick
Products group Suitable for • Concrete • Natural stone • Solid brick • Perforated brick • Perforated cement
To fix • Boilers • Water heather Examples of applications
Installation sequence
Product information Characteristics • Heavy steel hook with plastic plug to fix boilers and water heaters
Suggestion for use • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation
Technical data
Description
Lt mm
d0 mm
h1 mm
Lp mm
Øp mm
I mm
244 TVH 14
75
14
85
98
8,8
18
Code
Installation data Recommended values in daN Materials Concrete C20/25 Double brick Uni with plaster
1 daN ≃1 kg TVH 14 120 90
328
d0 h 1 Lt Lp Øp l
= Hole diameter = Min. hole depth = Plug length = Hook length = Hook diameter = Distance
Perforated cement
Masonry and HSS drills
masonry and HSS drills
Vorpa GOLDCRAFT universal drill bit
Concrete
Solid brick
Natural stone
Metal
Wood
Glass block
PVC
product group Suitable • concrete • solid brick • natural stone • metal • wood • glass block • PVC • backed clay • porcellain
Drive
Execution
product information Characteristics • Universal drill bit with special cutting edge geometry. Thanks to diamond-ground carbide tips GOLDCRAFT drill bit is suitable for almost all materials. Benefits • Special cutting edge geometry (see diagram) • The asymmetric spiral shape enable an optimum removal of drilling dust • High-temperature brazing at about 1.120 °C • Special cutting helix with micro surface hardness • Extremely wear resistant Suggestion for use • Regrinding of the carbide tip becomes necessary during prolonged use • Higher wear of carbide tip when drilling in abrasive materials • Only use sharp drill bits for drilling in porcelain, ceramics, glass block technical data Guide values for universal drill bits Goldcraft D
4
/mm
Ø mm
16
2350
1500
soft wood
1880
1030
ceramics
1580
800
1120
640
steel, cast steel
1700
510
hard wood
850
410
glass, crystal
masonry, marble, artificial stone,concrete granite, tiles, plastic materials, acrylic
330
Backed clay
Porcellain
masonry and HSS drills
Vorpa GOLDCRAFT universal drill bit
Concrete
Solid brick
Natural stone
technical data Vorpa GOLDCRAFT® Code
Description
5001 GOLDCRAFT 3 5002 GOLDCRAFT 4 5003 GOLDCRAFT 5 5004 GOLDCRAFT 5,5 5005 GOLDCRAFT 6 5006 GOLDCRAFT 6,5 5007 GOLDCRAFT 7 5008 GOLDCRAFT 8 5009 GOLDCRAFT 9 5010 GOLDCRAFT 10 5011 GOLDCRAFT 12 P1 long series mm 150 - 200
Code
5021 5022 5023 5024 5025 5026
X 70 X 75 X 85 X 85 X 100 X 100 X 100 X 120 X 120 X 120 X 150
Description
GOLDCRAFT P1 5 X 150 GOLDCRAFT P1 6 X 150 GOLDCRAFT P1 6,5 X 150 GOLDCRAFT P1 8 X 200 GOLDCRAFT P1 10 X 200 GOLDCRAFT P1 12 X 200
Usable length mm
Shank diameter mm
40 40 50 50 60 60 60 80 80 80 90
2,8 3,8 4,5 4,5 5,5 5,5 6,5 7,5 8 9 10
Usable length mm
Shank diameter mm
110 110 110 135 135 135
4,5 5,5 5,5 7,5 9 10
Vorpa GOLDCRAFT® Code
5030
Description
Goldcraft set
Set contents
5 GOLDCRAFT drills short version Ø mm 4 - 5 - 6 - 8 - 10
331
Metal
Wood
Glass block
PVC
Backed clay
Porcellain
masonry and HSS drills
Vorpa HARDTECH drill bit for hardtest materials
Concrete
Natural stone
Glass block
Backed clay
Porcellain
Product group Materials: • Expert for granite, gneissic rock, slate, basalt • Specially suitable for hard ceramic tiles, porcelain and other hard materials
Prüfgemeinschaft Mauerbohrer (PGM) Certified product
Drive
Execution 120°
Product information Characteristics • Hard stone drill bit with special cutting edge geometry Application • ISO 5468 • Asymmetric spiral shape • Staight flute entry • Milled flute • Spacial carbide tip • Diamond-ground carbide tip • High-temperature vacuum brazing at 1120°C • Ground surface
Advantages • Wear resistant carbide drill bit with long life time • High drilling speed • The drill bit can be resharpened with a diamond or silicon carbide grinding wheel • Very long service life Special carbide tip • High portion of tungsten carbide • Homogenious fine structured grain • Special cutting edge of 120°C • Preceise diamond grinding
Technical data
Code
8062 8063 8064 8065 8066
Code
8067
Description
HARDTEC 4 X 75 HARDTEC 5 X 85 HARDTEC 6 X 100 HARDTEC 8 X 120 HARDTEC 10 X 120
Description
HARDTEC set
Usable length mm
Shank diameter mm
40 50 60 75 75
4 5 6 8 10
Set contents
5 HARDTEC drills Ø mm. 4 - 5 - 6 - 8 -10
332
masonry and HSS drills
Vorpa PMS
metal universal drill bit for masonry
Concrete
Solid brick
Natural stone
product group Suitable • concrete • solid brick • natural stone
Drive
Execution
product information Characteristics • metal universal drill bit for masonry
Benefits • good chip and dust removal • for hobbyist and professional use
technical data
Code
6001 6002 6003 6004 6005 6006 6007 6008 6009 6010 6011 6012 6013 6014 6015 6016 6017 6018 6019 6020
Description
Shank diameter mm
PM S 3 X 60 PM S 4 X 75 PM S 4,5 X 85 PM S 5 X 85 PM S 5,5 X 85 PM S 6 X 100 PM S 6,5 X 100 PM S 7 X 100 PM S 8 X 120 PM S 8,5 X 120 PM S 9 X 120 PM S 10 X 120 PM S 11 X 150 PM S 12 X 150 PM S 13 X 150 PM S 14 X 150 PM S 15 X 150 PM S 16 X 150 PM S 18 X 160 PM S 20 X 160
2,5 3,5 3,5 4 4 5 5 5,5 6 6 7 8 8 8 8 10 10 13 13 13
Code
6060
Code
Description
P1 long series mm 150 - 200 6032 PM SP1 6 X 200 6033 PM SP1 8 X 200 6034 PM SP1 1 0 X 200 6035 PM SP1 1 2 X 200 6036 PM SP1 14 X 200 P2 long series mm 400 6040 PM SP2 8 X 400 6041 PM SP2 1 0 X 400 6042 PM SP2 1 2 X 400 6043 PM SP2 1 4 X 400 6044 PM SP2 1 6 X 400 6045 PM SP2 1 8 X 400 6046 PM SP2 2 0 X 400 P3 long series mm 600 6050 PM SP3 8 X 600 6051 PM SP3 10 X 600 6052 PM SP3 1 2 X 600 6053 PM SP3 1 4 X 600 6054 PM SP3 1 6 X 600 6055 PM SP3 1 8 X 600 6056 PM SP3 20 X 600
Description
Content
5 PM S drills short version
SET PM S
PMS set
Ø mm. 4 - 5 - 6 - 8 -10
333
Shank diameter mm
5 6 8 8 10 6 8 8 10 13 13 13 6 8 8 10 13 13 13
masonry and HSS drills
Vorpa SDS TURBO PRO
4 cutting edges drill bit suitable for concrete, professional use
Concrete
Solid brick
Natural stone
product group Suitable • concrete • solid brick • natural stone
Drive
Execution
product information Characteristics • X-Shape 4 cutting edges drill bit for perforated hammers, professional use • Made of chrome-nickel-molybdenum steel, shot-peened and hardened • Specially designed head geometry for better center drilling • Conical spiral drill bit Benefits • High drilling speed thanks to the helix carrying forward the impact of the machine up to the drilling head • Low hand-arm vibrations thanks to the helix concept reducing the vibration loads generated during drilling • High stiffness and longer service life • 2 larger-volume flutes granting ideal and fast drilling-dust removal • Greater fracture resistance thanks to the rounded step transitions and the strengthened core • The geometry with 4 cutting edges protects the bit against damage when impacting on reinforced steel • Head geometry characterized by 6 drill-levels. Different setting depths of major and side plates. Shearing force is shared on 2 levels and secure a long life • Cylindrical drilling holes, also in reinforced concrete. Drilling process will not be distracted
1) Higher drilling speed - The symmetric X-shape achieves higher drilling speed, in comparison to standard 90° design - X-shape with big entry-flutes for optimized drill-dust removal 2) Higher strength - Precise spot-drilling due to the centering point. Armor-resistant and easy drilling into reinforced concrete - The multi-angle drill bit tip achieves an ideal drilling result, with long service life at the same time
3) More clean - 4 cutting edges concept provide an accurate and correct guidance of the drill bit. Optimum vibration behavior 4 times secured quality due to: - Optimized hardening and brazing process at 1.120° - Second “stress-free” hardening - Shot-blased surface - Straightening process for exact true-running accuracy
334
masonry and HSS drills
Vorpa SDS TURBO PRO
4 cutting edges drill bit suitable for concrete, professional use
Concrete
technical data
Code
7130 7131 7132 7133 7134 7135 7136 7137 7138 7139 7140 7141 7142 7143 7144 7145 7146 7147 7148 7149 7150 7151 7152 7153 7154
Code
7160
Description
SDS TURBO 5 x 110 SDS TURBO 5 x 160 SDS TURBO 5 x 210 SDS TURBO 6 x 110 SDS TURBO 6 x 160 SDS TURBO 6 x 210 SDS TURBO 6 x 260 SDS TURBO 8 x 110 SDS TURBO 8 x 160 SDS TURBO 8 x 210 SDS TURBO 8 x 260 SDS TURBO 10 x 160 SDS TURBO 10 x 210 SDS TURBO 10 x 260 SDS TURBO 10 x 310 SDS TURBO 10 x 460 SDS TURBO 12 x 160 SDS TURBO 12 x 210 SDS TURBO 12 x 260 SDS TURBO 12 x 310 SDS TURBO 12 x 450 SDS TURBO 14 x 160 SDS TURBO 14 x 210 SDS TURBO 14 x 260 SDS TURBO 14 x 450
Description
Set SDS TURBO
Box (pcs)
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Box (pcs)
1
Usable length mm
50 100 150 50 100 150 200 50 100 150 200 100 150 200 250 400 100 150 200 250 400 100 150 200 400
Set contents
7 drills SDS TURBO Ã&#x2DC; mm. 5x110 - 6x110 - 6x160 8x110 - 8x160 - 10x160 - 12x160
335
Solid brick
Natural stone
masonry and HSS drills
Vorpa SDS PLUS
hammer drill bit, professional use
Concrete
product group Suitable • concrete • solid brick • natural stone
Drive
Execution
product information Characteristics • Made of chrome-nickel-molybdenum steel, shot-peened and intermediate level hardened • Specially designed carbide plate with centring tip • Multi-step helix Benefits • Reduces vibration loads generated during drilling • Reduces torsion loads generated during drilling • No drilling dust • Higher drilling speed • Transports the impact energy of the hammer drilling machine in an optimal way • Greater fracture resistance • Larger cutting angle • 64% faster thanks to Multi-step helix The helix is protected by patents. The number of spiral steps and radiuses on the drill depends on the hole diameter
4 – 5 mm 6 – 7 mm 8 – 9 mm 10 – 12 mm 13 – 14 mm 15 – 16 mm 17 – 26 mm
2 spiral steps 4 spiral steps 6 spiral steps 8 spiral steps 6 spiral steps 8 spiral steps 10 spiral steps
6 radiuses 10 radiuses 14 radiuses 18 radiuses 14 radiuses 18 radiuses 22 radiuses
Suggestion for use • For a working length of 400 mm and more, pre-drilling must be carried out to a depth of at least 150 mm with a drill bit of the same diameter. • For a working length of 950 mm and more, pre-drilling must be carried out to a depth of at least 400 mm with a short drill bit of the same diameter. • The warranty does not apply to extra-long drill bits of 1.000 mm and more.
336
Solid brick
Natural stone
masonry and HSS drills
Vorpa SDS PLUS
hammer drill bit, professional use
Concrete
technical data
Code
2000 1997 1998 2001 2002 2003 2004 2033 2005 2006 2007 2008 2009 2046 2034 2041 2035 2010 2011 2012 2042 2043 2013 2036 2014 2044 2015 2016 2031 2018 2019 2020 2021 2032 2022 2023 2048 2024 2039 2025 2040 2026 2037 2027 2038 2028 2049 2029 2030
Description
SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS
-PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS
4 X 4 X 4 X 5 X 5 X 6 X 6 X 6 X 7 X 7 X 8 X 8 X 8 X 8 X 8 X 8 X 9 X 9 X 10 X 10 X 10 X 10 X 10 X 10 X 12 X 12 X 12 X 12 X 12 X 14 X 14 X 14 X 14 X 14 X 15 X 16 X 16 X 16 X 16 X 18 X 18 X 20 X 20 X 20 X 20 X 22 X 24 X 25 X 26 X
110 160 180 110 160 110 160 210 110 160 110 160 210 310 400 460 160 210 110 160 210 260 310 460 165 210 265 450 600 165 215 315 450 600 165 215 310 450 600 200 300 200 300 450 600 450 250 450 450
Box (pcs)
Usable length mm
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
50 100 120 50 100 50 100 150 50 100 50 100 150 250 350 410 100 150 50 100 150 200 250 400 100 150 200 400 550 100 150 250 400 550 100 150 250 400 550 150 250 150 250 400 550 400 210 400 400
337
Solid brick
Natural stone
masonry and HSS drills
Vorpa SDS PLUS V4
hammer drill bit 4 cutter, professional use
Concrete
Solid brick
product group Suitable • concrete • solid brick • natural stone
Drive
Execution
product information Characteristics • Hammer drill bit 4 cutter, professional use
Benefits • Considerably faster drilling progress • Significantly longer life • High drilling speed • Fast transport of drilling dust • High grade of stiffness and long service life • High resistance against breakage
Benefits • Carbide plate with centring tip • Straight flute entry • High-temperature brazing at about 1100°C • Particulary suitable for fastenings • Simple precise drilling of pilot holes
technical data
Code
2149 2051 2052 2053 2054 2055 2150 2151 2056 2057 2058 2059 2171 2155 2060 2061 2062 2063 2172 2064 2065 2066 2067 2159 2068
Description
SDS-plus 4 X 110 SDS-plus 5 X 110 SDS-plus 5 X 160 SDS-plus 6 X 110 SDS-plus 6 X 160 SDS-plus 6 X 210 SDS-plus 7 X 110 SDS-plus 7 X 160 SDS-plus 8 X 110 SDS-plus 8 X 160 SDS-plus 8 X 210 SDS-plus 8 X 260 SDS-plus 8 X 450 SDS-plus 9 X 160 SDS-plus 10 X 110 SDS-plus 10 X 160 SDS-plus 10 X 210 SDS-plus 10 X 260 SDS-plus 10 X 450 SDS-plus 12 X 160 SDS-plus 12 X 210 SDS-plus 12 X 260 SDS-plus 12 X 450 SDS-plus 12 X 600 SDS-plus 14 X 160
Usable length mm
Code
2069 2070 2071 2162 2072 2073 2074 2075 2165 2076 2077 2166 2167 2078 2079 2080 2081 2169 2082 2168 2083 2170 2084
50 50 100 50 100 150 50 100 50 100 150 200 400 100 50 100 150 200 400 100 150 200 400 550 100
338
Description
SDS-plus 14 X 210 SDS-plus 14 X 260 SDS-plus 14 X 450 SDS-plus 14 X 600 SDS-plus 16 X 160 SDS-plus 16 X 210 SDS-plus 16 X 260 SDS-plus 16 X 450 SDS-plus 16 X 600 SDS-plus 18 X 210 SDS-plus 18 X 260 SDS-plus 18 X 450 SDS-plus 20 X 210 SDS-plus 20 X 260 SDS-plus 20 X 450 SDS-plus 20 X 600 SDS-plus 22 X 450 SDS-plus 24 X 260 SDS-plus 24 X 450 SDS-plus 25 X 260 SDS-plus 25 X 450 SDS-plus 25 X 600 SDS-plus 26 X 600
Usable length mm
150 200 400 550 100 150 200 400 550 150 200 400 150 200 400 550 400 200 400 200 400 550 550
Natural stone
masonry and HSS drills
Vorpa HSS DIN 338
Twist drill bit for use on materials, with a tensile strength up to 800 N/m2
Metal
Cast iron
Brass
product group Suitable • metal • cast iron • brass
Drive
Execution
product information Characteristics • High performance high-speed steel drill bit suitable for metal Benefits • High elasticity due to heat forming • Robust core thickness and distinct hardness • Special surface treatment reducing dust deposition • Reduced danger of breakage thanks to the torsional strength • Particularly suitable for professional use in metal, alloyed and unalloyed steel with a tensile strength up to 800 N/mm2, non-iron metal, cast iron and hard plastic
Suggestions for use • In case of horizontal drilling and drilling depths 5 times bigger than diameter it is necessary to reduce the drilling speed of 20-40% • Use special drilling oils in case of extremely hard alloy and heat resistant materials • Use normal freezing mixtures for standard steel or low adhesiveness materials • Dry-drilling in case of short chips, brass and cast iron • Lift the drill bit for time to time in order that the oil can pene trate into the material • Sharpen the cutting edges regularly • Do not use drill bits with rotopercussion
technical data
HSS DIN 338
Code
7001 7040 7002 7041 7003 7042 7004 7043 7005 7044 7006 7045 7007 7046 7008 7047
Description
HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS
1 X 34 1,25 X 38 1,50 X 40 1,75 X 46 2 X 49 2,25 X 53 2,50 X 57 2,75 X 61 3 X 61 3,25 X 65 3,50 X 70 3,75 X 70 4 X 75 4,25 X 75 4,50 X 80 4,75 X 80
Usable length mm
12 16 18 23 24 27 30 33 33 36 39 39 43 43 47 47
339
masonry and HSS drills
Vorpa HSS DIN 338
Twist drill bit for use on materials, with a tensile strength up to 800 N/m2
Metal
technical data
HSS DIN 338
Code
Description
7009 7048 7010 7049 7011 7050 7012 7051 7013 7014 7015 7016 7017 7018 7019 7020 7021 7022 7023 7024 7025
HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS
Usable length mm
5 X 86 5,25 X 86 5,50 X 93 5,75 X 93 6 X 93 6,25 X 101 6,50 X 101 6,75 X 109 7 X 109 7,50 X 109 8 X 117 8,50 X 117 9 X 125 9,50 X 125 10 X 133 10,50 X 133 11 X 142 11,50 X 142 12 X 151 12,50 X 151 13 X 151
52 52 57 57 57 63 63 69 69 69 75 75 81 81 87 87 94 94 101 101 101
Guidelines for the execution of pre-drills to thread according to trhead type M
D
3 4 5 6 8 10 12
2,4 - 2,5 3,2 - 3,3 4,0 - 4,2 4,8 - 5,0 6,4 - 6,8 7,9 - 8,5 9,6 - 10,2
art 7030
Code
7030 7031 7034 7032
art 7031
art 7034
Description
Diameter every 0,5 mm
19 drill bit 25 drill bit 13 drill bit 19 drill bit
from 1 to 10 from 1 to 13
art 7032
Diameter every 0,5 + Ã&#x2DC; 3,2 and 4,8 mm
Diameter every 1 mm
Box type
Metal Metal Plastic Metal
from 1,5 to 6,5 from 1 to 10
340
Cast iron
Brass
masonry and HSS drills
Vorpa HSS CO 5% DIN 338
5% cobalt twist drill bit for use on materials with a tensile strenght above 800N/m2, professional use
A2 stainless steel Special A4 stainless steel alloys
Alloyed stell
product group Suitable • A2 stainless steel • A4 stainless steel • special alloys • alloyed steel
Drive
Execution
product information Code
7100 7101 7102 7103 7104 7105 7106 7107 7108 7109 7110 7111 7112 7113 7114 7115 7116 7117 7118 7119 7120 7121 7122 7123 7124 7125 7126
Description
HSS Co 5% 1x34 HSS Co 5% 1,5x40 HSS Co 5% 2x40 HSS Co 5% 2,5x57 HSS Co 5% 3x61 HSS Co 5% 3,2x65 HSS Co 5% 3,5x70 HSS Co 5% 4x75 HSS Co 5% 4,2x75 HSS Co 5% 4,5x80 HSS Co 5% 5x86 HSS Co 5% 5,5x93 HSS Co 5% 6x93 HSS Co 5% 6,5x101 HSS Co 5% 7x109 HSS Co 5% 7,5x109 HSS Co 5% 8x117 HSS Co 5% 8,5x117 HSS Co 5% 9x125 HSS Co 5% 9,5x125 HSS Co 5% 10x133 HSS Co 5% 0,5x133 HSS Co 5% 11x142 HSS Co 5% 11,5x142 HSS Co 5% 12x151 HSS Co 5% 12,5x151 HSS Co 5% 13x151
Usable length mm
12 18 24 30 33 36 39 43 43 47 52 57 57 63 69 69 75 75 81 81 87 87 94 94 101 101 101
19 drill bits set
Code
7037 7038
Shank diameter mm
Characteristics • Cross-ground finish to DIN 1412 C (5% cobalt from Ø 3,0 mm). 135° conical section.
1,0 1,5 2,0 2,5 3,0 3,2 3,5 4 4,2 4,5 5 5,5 6 6,5 7 7,5 8 8,5 9 9,5 10 10,5 11 11,5 12 12,5 13
Benefits • Direct drilling without prior centering or drilling of a pilot hole • Safe pilot hole drilling, even in slanting surfaces, in pipes and/ or welds • The feeding power is reduced by up to 50% • Even chip removal and reduction of chip friction • Extremely true running and precise round holes • The drill bit facilitates an increase in drilling progress by up to 45% • No jamming of the main cutting edge and no slipping of the drill bit for through-holes • High fracture strength and long life • Reduced friction due to external diameter tapering in the shank direction • Fast drilling progress through chemical thermal method of hardening and accurate cross-ground finish • Due to the alloying addition of 5% Co these drill bits are well- suited for workpieces with a tensile strength of more than 800N/mm2. • Extra high temperature strength to cope with suboptimal supply of coolant • Up to 20% higher durability than identically constructed HSS drill bits used under the same operating conditions Suggestions for use • Use special drilling oils in case of extremely hard alloy and heat resistant materials • Use normal freezing mixtures for standard steel or low adhesiveness materials • Dry-drilling in case of short chips, brass and cast iron • Lift the drill bit for time to time in order that the oil can penetrate into the material • Sharpen the cutting edges regularly • Do not use drill bits with rotopercussion
25 drill bits set
Description
Diameter every 0,5 mm
19 drill bits 25 drill bits
from 1 to 10 from 1 to 13
Box type
Metal Metal
341
PERSONALIZED YOUR SHOP
DIY products require a good looking environment that can make a positive impression on the customers. It is very important to lay down an interior by using the right displays and the best layout. Vorpa is here to offer the solution suitable for different needs. Moreover you can rely on a well-known brand, professional and high quality products and wide range satisfying eny DIY fixing requirement.
about us
Who we are Vorpa is a company specialized in the design and production of fixing systems that achieved a significant position in the Italian and European market, thanks to precise orientations focused on two priority objectives: to provide an excellent level of manufacturing quality and strengthen all initiatives that provide value-added with the service to building and hardware distributors.
How to reach us
TRIESTE PADOVA
MILANO
VENEZIA
RICCIONE
TORINO GENOVA
BOLOGNA RICCIONE FIRENZE REP. SAN MARINO
Contact ol
B
Instagram Twitter
na
og
www.vorpa.com
A
ut
RIMINI SUD Casello - Exit
Rimini
os
tr
ad
RICCIONE Casello - Exit
a
RICCIONE
A
CATTOLICA Casello - Exit
14
Cattolica
M
ot
or
w
A
ay
ANCONA
a
on
nc
www.vorpa.com
Srl