Catalogue vorpa 2018

Page 1

www.vorpa.com

2018

General Catalogue


General Catalogue 2018


products index

from page 11

1

from page 89

2

from page 173

3

from page 259

4

CHEMICAL ANCHORS

MECHANICAL HEAVY DUTY ANCHORS

FRAME AND GENERAL FIXINGS

SCAFFOLDING ANCHORS


products index

from page 280

5

from page 295

6

from page 329

7

from page 342

8

FIXINGS FOR INSULATION

CLADDING AND PIPE FIXINGS

MASONRY AND HSS DRILLS

SELF SERVICE


index by base material

Pag.

chemical anchors

in corso

In progress

CV.RE PRO 500

14

CV VSF PRO

23

CV ESF

31

CV.PSF

38

CV.PSF WINTER 410

45

CV.PSF TROPICAL 410

52

CV.PE

59

CV MULTISET PLUS 66 BITUMPHALTE 130 BITUM

69

EXTRUSION TOOLS FOR CHEMICAL ANCHORS

70

EASY PRESS 14,4V

71

ACCESSORIES

71

VF CE RESIN CAPSULES

83

FOAMPLUS UNIVERSAL

85

FOAMPLUS FOR ROOFING

86

FOAMFAST 750

87

self-expanding foams

= good

= good with limitations

Concrete

Natural stone

Solid brick

Perforated Perforated brick cement

Aerated poroton

Wood


index by base material

Pag.

mechanical heavy duty anchors

= good

VEX + SEISMIC

90

VE.1CE + SEISMIC

97

VE.7CE

101

VE.A

107

VE

113

VE.AL

115

VSA

116

VSP

120

VSX

124

CSB CE + SEISMIC

126

VA - VA CE

129

VA - VA F CE

130

TOP

132

TOP SA

139

AV

141

AVZ

145

VHM

147

AVZ G

149

VHS

151

VTS

157

VO

158

VHS AF

161

VHS AE

161

TOP AF

165

TOP AE

165

VH AE

167

ACCESSORIES

168

= good with limitations

Concrete

Natural stone

Solid brick

Perforated brick

Aerated poroton

Perforated cement

Aerated concrete

Wood

Boards and panels


index by base material

Pag.

Concrete

frame fixings / universal fixings THERMOISO PLUS

174

CLICK-UP

179

VK - TV Z

183

VN

189

SU P

192

VR

194

ZV

196

SV

201

VE O

206

HC - HR

207

HZ - HB

209

HU - HS

210

PC - NAF

213

VB - VBD

215

HZB

222

VPX - VP ZIP - VP RAME 224

= good

VPO - VPI - VPI CE

229

VP C CE

235

VP R6 - VP R8

242

VP A

248

FSS - FSC

250

VGA - VGN

252

CLAPS

254

VSL

255

= good with limitations

Wood

Natural stone

Solid brick

Perforated brick

Aerated Poroton

Perforated cement

Aerated Plasterboard Boards and concrete panels


index by base material

Pag.

scaffolding anchors TOP T

260

VN P

262

VSP-P

267

KIT TESTER

269

AC

272

AC R

277

CLAMP

279

VPL

281

PVC SPACERS

283

ISO CE

284

ISO CE TL

292

Concrete

Natural stone

Solid brick

anti - falling nets anchors - ENEL-TELECOM

fixing for insulation

= good

= good with limitations

Insulation panels

Perforated brick

Aerated poroton

Perforated cement

Aerated concrete

Wood

Boards and panels


index by base material

Pag.

cladding and pipe fixings IF - IFO

296

BRM - BRG

298

VRM - VR

299

CAV - CAV P

301

CDS 1/2� GAS

304

CFI

306

CFZ

307

CP

308

VCR

309

CT

310

KPO - KP

311

TC

313

FZ

316

SL

317

SFT

318

SPS

319

BANDING ROLL

320

U-BOLT

321

VNS

322

TV - TV NK

323

TVH

328

fissaggi idrotermosanitari - sanitary fixings

= good

Concrete

Natural stone

Solid brick

Perforated brick

Aerated poroton

Perforated cement

Aerated Plasterboard Boards and concrete panels


index by base material

Pag.

punte professionali - masonry and HSS drills

= good

GOLDCRAFT

330

HARDTEC

332

PMS

333

SDS TURBO

334

SDS PLUS

336

SDS PLUS V4

338

HSS DIN 388

339

HSS 5%

341

Concrete

Natural stone

Solid brick

Wood

Glass bricks cement

PVC

Metal

Stainless steel

Special alloys

Granite and Refractory Porcellain material Gres Klimker


Chemical anchors


chemical anchors Didactic table CV.RE PRO 500

CV.ESF

CV.VSF PRO

Extremely low temperature

Low temperature

385 ml

300 ml

165 ml

585 ml

345 ml

300 ml

1400 ml

400 ml

410 ml

Medium temperature

High temperature

Certifications

SEISMIC C1-C2

ETAG 01-05 Option 1

M8-M30/Rebar Ø 8 to 32mm For use in cracked or non-cracked concrete seismic class C1-C2

C1-C2

M8-M24/Rebar Ø 8 to 25mm Uncracked concrete

(in progress)

ETAG 001-05 Option 1

ETAG 01-01 TR 023

ETAG 029

Use category C, w/d - size:M10

Tested for LEED compliancy

ETAG 01-05 Option 7

M12-M16 Cracked concrete

M8-M16 Uncracked Concrete Pending

For use in cracked concrete seismic class C1-C2

Post-Installed Rebar Ø 8 to 25mm

ETAG 01-05

Bonded anchor for diamond coring for use in uncracked concrete

SEISMIC ETAG 001-05 Option 7

ETAG 01-01 TR 023

Post-Installed Rebar Ø 8 to 16mm

FIRE RATED

ETAG 029

Use category C, w/d size: M8-M10-M12

FIRE RATED

Tested for LEED compliancy

0974/W

Base materials

CLS

CLS FESSURATO

CLS ARMATO

CLS

CLS CLS LATERIZIO FESSURATO ARMATO FORATO

CLS

LATERIZIO PIENO

LATERIZIO FORATO

To be used with

Water in hole condition

Anche acqua di mare Sizes according to certifications

Anche acqua di mare

M8 - M30 Threaded bar

M12 - M16 Threaded bar

Ø8 - Ø32 Rebars

Ø8 - Ø25 Rebars

12

Anche acqua di mare

M10 Threaded bar


chemical anchors Didactic table CV.PSF

CV.PE

CV.PSF SPECIAL

Extremely low temperature

Low temperature

165 ml

410 ml

300 ml Medium temperature

300 ml

410 ml

410 ml High temperature

410 ml

ETAG 029

ETAG 01-05 Option 7

Use category C, w/d - size:M10

M8-M16 Uncracked Concrete

Tested for LEED compliancy

* Winter type

ETAG 01-05 Option 7

M8-M16 Uncracked Concrete

0978/W

Certifications

*

Certificato su legno da

Tested for LEED compliancy

0978/W 0974/W

ETAG 029

Use category C, w/d size: M8-M10-M12

Tested for LEED compliancy

0978/W

Base materials

CLS

LATERIZIO LEGNO LATERIZIO PIENO FORATO

CLS

LATERIZIO PIENO

LATERIZIO FORATO

LATERIZIO PIENO

LATERIZIO FORATO To be used with

Water in hole condition

Sizes according to certifications

M8 - M16 Threaded bar

M8 - M16 Threaded bar

M8 - M16 Threaded bar

13


chemical anchors

Vorpa CV.RE PRO 500 - Fixing in seismic C1 - C2 - Annex E 3:1 high performance pure epoxy A+ rating resin with ETA option 1 for cracked and non-cracked concrete TR023 post installed rebar

Cracked and non-cracked concrete

products group Suitable • Cracked and non-cracked concrete • Fixing in seismic C1-C2

CV.RE PRO 500 - 1400ml

To fix • structural fixings • heavy duty metal structures • heavy structural works • construction joints • scaffolding links • wall ties, starter bars, studs, bolts & large screws • electric installations plumbing

AN

IEQc4.1

D

F

LI

TE TE S

CY

Styrene Free

OR

L EE D C O

M

P

CV.RE PRO 500 - 585ml CV.RE PRO 500 - 385ml

FIRE RATED

ETAG 001-01 Option 1 M8-M30/Rebar Ø8-32mm for use in cracked and uncracked concrete

ETAG 01-05 bonded anchor for diamond coring for use in uncracked concrete

ETAG 01-01 TR 023 post installed rebar Ø8 to 25mm

For more details please see ETA.

Examples of applications

14

FIXING IN SEISMIC C1-C2


chemical anchors

Vorpa CV.RE PRO 500 - Fixing in seismic C1 - C2 - Annex E 3:1 high performance pure epoxy A+ rating resin with ETA option 1 for cracked and non-cracked concrete TR023 post installed rebar

Cracked and non-cracked concrete

product information Characteristics • 3:1, high performance, rapid curing, two part chemical anchoring system based on Pure Epoxy Acrylate resin. Applied in one single action this resin will produce a high performance, strong fixing with exceptionally high chemical resistance.

Benefits • Zero shrinkage enables large diameter installations • Close edge distance and small spacing • Independently tested and approved - anchor life 50 years • For diamond drilled holes, with rebar, and in areas of high chemical exposure eg. Seasalt and swimming pools. • Long working times • Low odour A+ rating VOC content • ETA Option 1 ETAG 001 for cracked concrete with studs and rebar TR029 • ETA Option 1 ETAG 01-01 for rebar TR023 • ETA approved in flooded holes, wet and dry concrete • WRC Water Approval • F120 Fire Test report

Benefits • C2 seismic performance • High bond strength with High load resistance • Used with all grades of threaded rod and rebar in accordance with TR029 • Ideal for deep embedment installations • Used in dry and wet concrete • Used in flooded holes • Used for overhead applications • Ideal for diamond drilled holes • Ideal for elevate temperatures - temperature ranges I, II AND III/dielectric fixings • Ideal for rebar installation under TR029 and EN1992-1-1:2004 EC2

Suggestion for use • Performance based on clean holes. HAMMER DRILLED – blown and then brushed with a stiff metal brush and blown again.

installation sequence Solid brick

technical data Minimum Curing Time Concrete Temperature

Gel-working Time

≥ 5°C ≥ 15°C ≥ 25°C ≥ 35°C ≥ 40°C

120 min 60 min 25 min 16 min 10 min

Temperature Ranges Minimum curing time Minimum curing time in dry concrete in wet concrete

50 h 20 h 8h 4h 2,5 h

x2 x2 x2 x2 x2

- Full cure 24 hours - All specifications based on supplied mixer Physical Properties

N/mm2 (MPa)

Test Method

Tensile Strength Compressive Strength Flexural Strength Flexural Modulus E Modulus Density Shrinkage VOC Content

29,36 120 39 3706 3420 1,42 kg/dm3 < 0,4% A+

ASTM D638 EN 196 PARTE 1 EN 196 PARTE 1 ASTM D790 EN 196 PARTE 1 -

Temperature Range

Concrete Service Temperature

Range I Range II Range III

-40°C to +40°C -40°C to +60°C -40°C to +72°C

Maximum Long Term Maximum Short Term Concrete Temp Concrete Temp

+24°C +43°C +43°C

+40°C +60°C +72°C

Service temperature range: Range of ambient temperatures after installation and during the lifetime of the anchor. Short term temperature: Temperature within the service temperature range which vary over short intervals, e.g. day/night cycles and freeze/than cycles. Long term temperature: Temperature, within the service temperature range, which will be approximately constant over significant periods of time.

Code

1171 1173 1169

15

Description

CV. RE PRO 500 CV. RE PRO 500 CV. RE PRO 500

Content ml

Gun to be used

385 585 1400

side by side 3:1 side by side 3:1 side by side 3:1


chemical anchors

Vorpa CV.RE PRO 500 - Fixing in seismic C1 - C2 - Annex E 3:1 high performance pure epoxy A+ rating resin with ETA option 1 for cracked and non-cracked concrete TR023 post installed rebar

Cracked and non-cracked concrete

technical data Typical characteristic and design resistance performance with 5.8 grade studding and associated installation data Characteristic Resistance (kN) Ă˜ mm

8

10

12

16

20

24

27

30

33

36

Trazione (Nrk) 19,00 19,00 19,00 28,27 30,20 30,20 39,58 43,80 43,80 56,30 81,60 81,60 73,51 127,40 127,40 90,48 183,60 183,60 119,97 238,00 238,00 135,72 292,00 292,00 148,25 342,12 360,00 174,74 396,07 425,00

Taglio (Vrk)

9,00

15,00

21,00

39,00

61,00

88,00

115,00

142,50

173,50

212,50

Design Resistance (kN)

Recommended Load (kN)

Characteristic distances (mm)

Min Edge and Spacing

Nominal Embedment

Trazione (Nrd)

Trazione (Nrec)

Bordo Spacing Bordo (Ccr,N) (Scr,N) (Ccr,V)

(mm) (Cmin Smin)

(mm)

12,70 12,70 12,70 15,71 20,10 20,10 21,99 29,20 29,20 31,28 54,40 54,40 35,01 84,90 84,90 43,08 122,40 122,40 53,32 159,10 159,10 64,63 194,50 194,50 70,60 162,91 240,60 83,21 188,60 283,33

Taglio (Vrd)

7,20

12,00

16,80

31,20

48,80

70,40

92,00

114,00

138,80

170,00

9,07 9,07 9,07 11,22 14,36 14,36 15,71 20,86 20,86 22,34 38,86 38,86 25,00 60,64 60,64 30,77 87,43 87,43 38,08 109,52 109,52 46,16 133,33 133,33 50,43 116,36 165,20 59,43 134,72 202,38

Taglio (Vrec)

5,14

80

160

80

40

8,57

100

200

90

50

12,00

120

240

110

60

22,29

160

320

125

80

34,86

200

400

180

100

50,29

240

480

220

120

65,71

270

540

240

135

81,43

300

600

280

150

99,14

330

660

310

165

121,43

360

720

330

180

60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 110 240 540 120 280 600 130 300 660 150 340 720

Hole Hole Max diameter diameter Torque concrete fixture (mm)

(mm)

(Nm)

10

9

10

12

12

20

14

14

40

18

18

80

24

22

120

28

26

160

32

30

180

35

32

200

37

36

250

40

38

300

= Steel failure All data is based on correct installation - see instructions No influence of edge and spacing Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d

16


chemical anchors

Vorpa CV.RE PRO 500 - Fixing in seismic C1 - C2 - Annex E 3:1 high performance pure epoxy A+ rating resin with ETA option 1 for cracked and non-cracked concrete TR023 post installed rebar

Cracked and non-cracked concrete

technical data Design resistance with various stud strenghts and rebar 5.8 grade steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30 33 36

10 12 14 18 24 28 32 35 38 40

depth mm

hef failure

embedment depth 60 70 80 90 100 110 12.6 12.7 15.7 18.3 20.1 22.0 25.1 28.3 29.2 31.4 35.3 39.2 43.1 33.2 37.3 41.5 45.6 43.0 47.3 53.2

60

70

80

90

100

110

120

130

140

160

200

240

280

320

47.1 49.8 51.6 58.0 64.5

51.0 53.9 55.9 62.9 69.8 71.4

120

130

54.4 58.1 60.2 67.7 75.2 76.9 77.6 140

66.4 68.8 77.4 86.0 87.9 88.7 160

82.9 86.0 96.7 107.5 109.9 110.8 200

84.9 103.2 116.1 128.9 131.9 133.0 240

120.4 135.4 150.4 153.9 155.2 280

122.4 154.7 171.9 175.9 177.4 320

400

480

540

600

660

720

159.1 194.5 219.8 240.6 221.7 266.0 283.2 400 480 540 600

660

720

Fd,s design load

(mm)

(kN)

61 77 93 139 205 285 329 362 438 511

12.7 20.1 29.2 54.4 84.9 122.4 159.1 194.5 240.6 283.2

hef

Fd,s

8.8 grade steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30 33 36

10 12 14 18 24 28 32 35 38 40

depth mm

failure

embedment depth 60 70 80 12.6 14.7 16.8 15.7 18.3 20.9 22.0 25.1 31.4 33.2

60

70

80

90 18.8 23.6 28.3 35.3 37.3

90

100 19.5 26.2 31.4 39.2 41.5 43.0

100

110

120

28.8 34.5 43.1 45.6 47.3 53.2

30.9 37.7 47.1 49.8 51.6 58.0 64.5

110

120

130

140

160

200

240

280

320

400

480

540

40.8 51.0 53.9 55.9 62.9 69.8 71.4

44.0 54.9 58.1 60.2 67.7 75.2 76.9 77.6 140

45.0 62.7 66.4 68.8 77.4 86.0 87.9 88.7 160

78.4 82.9 86.0 96.7 107.5 109.9 110.8 200

83.7 99.5 103.2 116.1 128.9 131.9 133.0 240

116.1 120.4 135.4 150.4 153.9 155.2 280

130.7 137.5 154.7 171.9 175.9 177.4 320

171.9 193.4 214.9 219.8 221.7 400

188.3 232.1 257.9 263.8 266.0 480

244.8 290.1 296.7 299.3 540

130

600

660

720

299.2 329.7 362.7 370.1 332.5 365.8 399.1 600 660 720

design load

(mm)

(kN)

93 118 143 214 315 438 506 557 674 786

19.5 30.9 45.0 83.7 130.7 188.3 244.8 299.2 370.1 435.7

hef

Fd,s

A-70 stainless steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30 33 36

10 12 14 18 24 28 32 35 38 40

depth mm

failure

embedment depth 60 70 80 12.6 13.7 15.7 18.3 20.9 22.0 25.1 31.4 33.2

60

70

80

90

100

110

120

21.7 28.3 31.6 35.3 39.2 43.1 47.1 37.3 41.5 45.6 49.8 43.0 47.3 51.6 53.2 58.0 64.5

90

100

110

120

130

140

160

200

51.0 53.9 55.9 62.9 69.8 71.4

54.9 58.1 60.2 67.7 75.2 76.9 77.6 140

58.8 66.4 68.8 77.4 86.0 87.9 88.7 160

82.9 86.0 80.2 98.1 109.9 110.8 200

130

*1 = tensile strenght 500N/mm2

17

240

280

320

400

480

540

600

660

720

660

1 1 1 1 720

91.7 103.2 120.4 132.1

121 133.0 143 240 280

320

400

480

540

600

design load

(mm)

(kN)

65 83 100 150 221 307 166 183 221 258

13.7 21.7 31.6 58.8 91.7 132.1 80.2 98.1 121.3 142.8


chemical anchors

Vorpa CV.RE PRO 500 - Fixing in seismic C1 - C2 - Annex E 3:1 high performance pure epoxy A+ rating resin with ETA option 1 for cracked and non-cracked concrete TR023 post installed rebar

Cracked and non-cracked concrete

technical data High bond reinforcing bars Fyk = 800 N/mm2 Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 25 28 32 36 40

10 12 15 20 25 30 35 40 44 50

hef 60 70 80 11.7 13.7 15.6 14.7 17.1 19.6 19.1 21.8 26.8 28.7

depth mm

60

70

80

90 17.6 22.0 24.5 30.2 32.3

90

100 19.6 24.4 27.2 33.5 35.9 41.1

100

110 21.5 26.9 30.0 36.9 39.5 45.3 50.7

110

120 23.5 29.3 32.7 40.2 43.1 49.4 55.3

120

130 25.2 31.8 35.4 43.6 46.7 53.5 59.9 68.5

130

140 34.2 38.1 46.9 50.3 57.6 64.5 73.7 79.2 140

160 39.1 43.6 53.6 57.5 65.8 73.7 84.3 90.5 95.8 160

200

240

39.3 54.5 67.0 71.9 82.3 92.2 105.3 113.1 119.7 200

56.6 80.4 86.2 98.7 110.6 126.4 135.7 143.6 240

Fd,s

failure

embedment depth 280

93.8 100.5 115.2 129.0 147.5 158.4 167.6 280

320

400

100.6 114.9 131.7 147.5 168.5 181.0 191.5 320

143.6 164.6 184.3 210.7 226.0 239.4 400

500

205.7 230.4 263.3 282.8 299.2 500

560

258.1 294.9 316.7 335.1 560

640

720

800

337.1 362.0 407.2 383.0 430.9 478.8 640 720 800

design load

(mm)

(kN)

129 161 208 300 438 549 668 763 902 1050

25.2 39.3 56.6 100.6 157.1 226.0 308.0 402.1 510.0 628.3

Characteristic and Design Load resistances based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non Cracked Concrete Characteristic Resistance (kN) Ø mm

8

10

12

16

20

24

27

30

33

36

Tension (Nrk) 22,62 30,16 60,32 28,27 42,41 94,25 39,58 62,20 135,72 56,30 87,96 225,19 73,51 138,86 326,73 90,48 190,00 434,29 111,97 244,29 549,65 132,72 316,76 678,59 148,25 342,12 752,66 174,74 396,07 838,73

Shear (Vrk)

9,00

15,00

21,00

39,00

61,00

88,00

115,00

142,50

173,50

212,50

Cracked Concrete

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

12,57 16,76 33,51 15,71 23,56 52,36 21,99 34,56 75,40 31,28 48,87 125,11 35,01 66,12 155,58 43,08 90,48 206,81 53,32 116,33 261,74 64,63 150,80 323,14 70,60 162,91 358,41 83,21 188,60 399,40

Shear (Vrd)

7,20

12,00

16,80

31,20

48,80

70,40

92,00

114,00

138,80

170,00

8,98 11,97 23,94 11,22 16,83 37,40 15,71 24,68 53,86 22,34 34,91 89,36 25,00 47,23 111,13 30,77 64,63 147,72 38,08 83,09 186,96 46,16 107,71 230,81 50,43 116,37 256,01 59,43 134,72 285,28

Shear (Vrec)

Characteristic Resistance (kN) Tension (Nrk)

Shear (Vrk)

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

Shear (Vrd)

Shear (Vrec)

5,14 Not applicable

Not applicable

Not applicable

8,57 19,79 31,10 67,86 26,14 42,22 104,55 33,93 63,90 150,80 41,47 85,50 199,05 51,32 107,49 251,92 62,20 133,00 311,02 67,39 140,27 342,12 76,34 154,47 366,44

12,00

22,29

34,86

50,29

65,71

81,43

99,14

121,43

21,00

39,00

61,00

88,00

115,00

142,50

173,50

212,50

All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C

18

11,00 17,28 37,70 14,52 23,46 58,08 16,16 30,41 71,81 19,75 40,71 94,79 24,44 51,18 119,96 29,62 63,33 148,10 32,09 66,80 162,91 36,35 73,56 174,49

16,80

31,20

48,80

70,40

92,00

114,00

138,80

170,00

7,85 12,34 26,93 10,37 16,75 41,49 11,54 21,72 51,29 14,11 29,10 67,70 17,46 36,56 85,69 21,16 45,24 105,79 22,92 47,71 116,37 25,97 52,54 124,64

12,00

22,29

34,86

50,29

65,71

81,43

99,14

121,43

Nominal Embedment (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 110 240 540 120 280 600 130 300 660 150 340 720


chemical anchors

Vorpa CV.RE PRO 500 - Fixing in seismic C1 - C2 - Annex E 3:1 high performance pure epoxy A+ rating resin with ETA option 1 for cracked and non-cracked concrete TR023 post installed rebar

Cracked and non-cracked concrete

technical data Bond Strength Factors Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) fc=

C15/20

C20/25

C25/30

C30/37

C35/45

C40/50

C45/55

C50/60

0.98

1.00

1.02

1.04

1.06

1.08

1.09

1.10

Influence of environmental conditions in non cracked concrete

Temp I 40°C/24°C

Temp II 60°C/43°C

Temp II 72°C/43°C

M8

M10

M12

M16

M20

M24

M27

M30

M33

M36

Dry and Wet

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

Flooded

1.00

0.94

0.87

0.79

0.71

0.65

0.65

0.60

0.57

0.55

Dry and Wet

0.65

0.65

0.65

0.65

0.65

0.65

0.65

0.65

0.65

0.65

Flooded

0.65

0.63

0.61

0.59

0.57

0.54

0.50

0.49

0.46

0.44

Dry and Wet

0.57

0.56

0.54

0.53

0.52

0.51

0.50

0.49

0.47

0.46

Flooded

0.57

0.54

0.52

0.51

0.50

0.49

0.46

0.45

0.43

0.42

Influence of environmental conditions in cracked concrete

Temp I 40°C/24°C

Temp II 60°C/43°C

Temp II 72°C/43°C

M8

M10

M12

M16

M20

M24

M27

M30

M33

M36

Dry and Wet

n/a

n/a

0.50

0.48

0.46

0.45

0.44

0.42

0.41

0.39

Flooded

n/a

n/a

0.50

0.42

0.38

0.38

0.35

0.30

0.27

0.24

Dry and Wet

n/a

n/a

0.32

0.31

0.30

0.29

0.29

0.28

0.27

0.26

Flooded

n/a

n/a

0.32

0.29

0.28

0.27

0.27

0.25

0.24

0.23

Dry and Wet

n/a

n/a

0.27

0.27

0.26

0.25

0.24

0.23

0.23

0.22

Flooded

n/a

n/a

0.27

0.27

0.26

0.25

0.24

0.23

0.23

0.22

19


chemical anchors

Vorpa CV.RE PRO 500 - Fixing in seismic C1 - C2 - Annex E 3:1 high performance pure epoxy A+ rating resin with ETA option 1 for cracked and non-cracked concrete TR023 post installed rebar

Cracked and non-cracked concrete

technical data Characteristic and Design Load resistances for REBAR based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non Cracked Concrete Characteristic Resistance (kN) Ø mm

8

10

12

16

20

25

28

32

Tension (Nrk)

Shear (Vrk)

21,11 28,15 56,30 26,39 39,58 87,96 34,31 53,91 117,62 48,25 75,40 193,02 67,86 128,18 301,59 86,39 181,43 431,97 108,37 270,93 541,86 141,55 353,87 707,74

13,95

21,45

31,05

55,50

86,55

135,00

168,75

220,95

Cracked Concrete

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

Shear (Vrd)

11,73 15,64 31,30 14,66 21,99 48,87 19,06 29,95 65,35 26,81 41,89 107,23 32,31 61,04 143,62 41,14 86,39 205,70 51,61 129,02 258,03 67,40 168,51 337,02

9,30

14,30

20,70

37,00

57,70

90,00

112,50

147,30

8,38 11,17 22,34 10,47 15,71 34,91 13,61 21,39 46,68 19,15 29,92 76,60 23,08 43,60 102,58 29,39 61,71 146,93 36,86 92,15 184,31 48,15 120,36 240,73

Characteristic Resistance (kN)

Shear (Vrec)

Tension (Nrk)

Shear (Vrk)

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

Shear (Vrd)

Nominal Embedment

Shear (Vrec)

(mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 500 112 280 560 128 320 640

6,64 Not applicable

Not applicable

Not applicable

10,21 19,79 31,10 67,86 26,14 40,84 104,55 33,93 64,09 150,80 43,20 90,71 215,99 54,19 135,47 270,93 70,77 176,93 353,87

14,79

26,43

41,21

64,29

80,36

105,21

31,05

55,50

86,55

135,00

168,75

220,95

11,00 17,28 37,70 14,52 22,69 58,08 16,16 30,52 71,81 20,57 43,20 102,85 25,80 64,51 129,02 33,70 84,25 168,51

20,70

37,00

57,70

90,00

112,50

147,30

7,85 12,34 26,93 10,37 16,21 41,49 11,54 21,80 51,29 14,69 30,86 73,46 18,43 46,08 92,15 24,07 60,18 120,36

14,79

26,43

41,21

64,29

80,36

105,21

All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C

Bond Strength Factors - REBAR Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) fc=

C15/20

C20/25

C25/30

C30/37

C35/45

C40/50

C45/55

C50/60

C55/67

C60/75

C70/85

0.98

1.00

1.02

1.04

1.06

1.08

1.09

1.10

1.10

1.12

1.13

Influence of environmental conditions in non cracked concrete

Temp I 40°C/24°C

Temp II 60°C/43°C

Temp II 72°C/43°C

Ø8

Ø10

Ø12

Ø16

Ø20

Ø25

Ø28

Ø32

Dry and Wet

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

Flooded

1.00

0.94

0.90

0.85

0.80

0.71

0.65

0.63

Dry and Wet

0.67

0.65

0.63

0.62

0.61

0.60

0.60

0.59

Flooded

0.65

0.64

0.61

0.59

0.58

0.56

0.55

0.47

Dry and Wet

0.60

0.58

0.57

0.56

0.56

0.55

0.54

0.53

Flooded

0.58

0.56

0.53

0.50

0.47

0.45

0.43

0.41

20

C80/96 C90/105 1.14

1.15


chemical anchors

Vorpa CV.RE PRO 500 - Fixing in seismic C1 - C2 - Annex E 3:1 high performance pure epoxy A+ rating resin with ETA option 1 for cracked and non-cracked concrete TR023 post installed rebar technical data Influence of environmental conditions in cracked concrete

Temp I 40°C/24°C

Temp II 60°C/43°C

Temp II 72°C/43°C

Ø8

Ø10

Ø12

Ø16

Ø20

Ø25

Ø28

Ø32

Dry and Wet

n/a

n/a

0.55

0.47

0.44

0.43

0.42

0.41

Flooded

n/a

n/a

0.55

0.42

0.40

0.38

0.36

0.35

Dry and Wet

n/a

n/a

0.30

0.28

0.26

0.24

0.23

0.23

Flooded

n/a

n/a

0.30

0.27

0.25

0.23

0.22

0.22

Dry and Wet

n/a

n/a

0.30

0.26

0.25

0.24

0.23

0.22

Flooded

n/a

n/a

0.30

0.26

0.24

0.23

0.23

0.22

Post installed rebar connections Minimum anchorage length 1) and lap splice length for C20/25 and maximum installation length (l max) Rebar

lb,min (mm)

lo,min (mm)

lmax,min (mm)

Ø ds

fy,k (N/mm2)

8mm

500

113

200

1000

10mm

500

142

200

1000

12mm

500

170

200

1200

14mm

500

198

210

1400

16mm

500

227

240

1600

20mm

500

284

300

2000

22mm

500

312

330

2000

24mm

500

340

360

2000

25mm

500

354

375

2000

N/mm2 = MPa

1) According to EN 1992-1-1:2004 lb,min (8.6) e lo,min (8.11) for good bond conditions and as = 1,0 with maximum yeld stress for rebar B500 e yM - 1,15

Design values of the ultimate bond resistance fbd 1) in N/mm2 for all drilling methods for good conditions Rebar Ø

Concrete Class

Ø ds

C12/15

C16/20

C20/25

C25/30

C30/37

C35/45

C40/50

C45/60

C50/60

8mm to 25mm

1.6

2

2.3

2.7

3

3.4

3.7

4

4.3

1) Tabulated values for fbd are valid for good bond condition according to EN 1992-1-1:2004. For all other bond conditions multiply the values for fbd by 0.7.

21

Cracked and non-cracked concrete


chemical anchors

Vorpa CV.RE PRO 500 - Fixing in seismic C1 - C2 - Annex E 3:1 high performance pure epoxy A+ rating resin with ETA option 1 for cracked and non-cracked concrete TR023 post installed rebar

Cracked and non-cracked concrete

technical data Effect of anchor spacing - Tension Anchor spacing (mm) (mm) 40 50 60 70 80 90 100 120 150 160 175 200 225 240 250 275 280 300 320 350 400 440 480 540 600 660 720 800

Effect of edge distance - Tension Edge distance (mm) 40 50 60 70 80 90 100 110 120 140 160 180 200 220 240 270 300 330 360 400

Stud/Rebar diameter 8 0,64 0,67 0,70 0,73 0,76 0,79 0,82 0,87 0,96 1,00

10

0,63 0,65 0,67 0,69 0,72 0,74 0,79 0,86 0,88 0,92 1,00

12

0,63 0,64 0,66 0,68 0,70 0,74 0,80 0,82 0,85 0,90 0,95 1,00

16

0,63 0,64 0,65 0,68 0,73 0,74 0,76 0,80 0,84 0,86 0,87 0,91 0,92 0,95 1,00

20

0,63 0,65 0,68 0,70 0,71 0,74 0,77 0,79 0,80 0,83 0,84 0,86 0,88 0,92 1,00

24

0,63 0,65 0,66 0,67 0,69 0,72 0,73 0,74 0,76 0,77 0,79 0,81 0,83 0,88 0,92 1,00

27

0,63 0,64 0,65 0,66 0,69 0,71 0,72 0,73 0,75 0,76 0,78 0,80 0,82 0,87 0,91 0,94 1,00

30

0,63 0,63 0,64 0,66 0,68 0,69 0,70 0,72 0,73 0,74 0,76 0,78 0,82 0,85 0,88 0,93 1,00

33

0,63 0,63 0,65 0,67 0,68 0,69 0,71 0,71 0,73 0,74 0,77 0,80 0,83 0,86 0,91 0,96 1,00

36

0,63 0,63 0,65 0,67 0,68 0,68 0,70 0,70 0,72 0,73 0,75 0,78 0,81 0,84 0,88 0,92 0,96 1,00

40

0,63 0,63 0,65 0,66 0,67 0,68 0,69 0,69 0,71 0,72 0,73 0,76 0,79 0,81 0,84 0,88 0,91 0,95 1,00

Stud/Rebar diameter 8 0,64 0,73 0,82 0,90 1,00

10 0,63 0,70 0,77 0,84 0,91 1,00

12

0,63 0,68 0,74 0,80 0,86 0,92 1,00

16

0,63 0,67 0,71 0,76 0,80 0,89 1,00

20

0,63 0,66 0,70 0,77 0,84 0,91 1,00

24

0,64 0,67 0,72 0,78 0,84 0,89 1,00

27

30

0,63 0,70 0,75 0,81 0,86 0,92 1,00

0,63 0,65 0,70 0,76 0,81 0,86 0,94 1,00

27

30

0,35 0,51 0,63 0,75 0,88 1,00

0,30 0,35 0,46 0,57 0,68 0,78 1,00

33

36

0,63 0,66 0,71 0,75 0,80 0,87 0,94 1,00

0,67 0,71 0,74 0,78 0,82 0,87 0,93 0,98 1,00

33

36

0,32 0,37 0,46 0,56 0,65 0,84 1,00

0,33 0,43 0,50 0,56 0,63 0,77 1,00 1,00

40

0,68 0,71 0,75 0,78 0,83 0,88 0,93 0,98 1,00

Effect of edge distance - Shear Edge distance (mm) 40 50 60 70 80 90 100 110 125 140 160 180 200 220 240 280 310 330 400

22

Stud/Rebar diameter 8 0,25 0,44 0,63 0,81 1,00

10 0,30 0,48 0,65 0,83 1,00

12

0,30 0,44 0,58 0,72 0,86 1,00

16

20

24

0,40 0,53 0,67 0,35 0,80 0,44 1,00 0,58 0,35 0,72 0,46 0,91 0,62 1,00 0,77 0,92 1,00

40

0,32 0,53 0,59 0,72 0,82 0,89 1,00


chemical anchors

Vorpa CV.VSF CE PRO

Vinylester styrene free chemical anchor with European Technical Approval for non-cracked concrete cracked concrete, post installed rebar

Cracked and non-cracked concrete

Natural stone

Solid brick

Marble

Wood

products group

CV.VSF PRO 300 CE

Suitable • Cracked and non-cracked concrete • Natural stone • Solid brick • Marble • Wood

To fix • structural fixings • heavy duty metal structures • heavy structural works • construction joints • scaffolding links • wall ties, starter bars, studs, bolts & large screws • electric installations plumbing

ETAG 01-01 TR023 Post installed Rebar Ø 8 to Ø 16 mm

ETAG 001-05 Option 7 M8-M24 / Rebars Ø 8 to 25 mm For non-cracked concrete

ETAG 001-05 Option 1 M12-M16 / Threaded bars For cracked concrete

FIXING IN SEISMIC * C1-C2

CV.VSF PRO 345 CE

* C1-C2 SEISMIC ETA PENDING CV.VSF PRO 400 CE FIRE RATED

23

Styrene Free

Tested for LEED compliancy


chemical anchors

Vorpa CV.VSF CE PRO

Vinylester styrene free chemical anchor with European Technical Approval for non-cracked concrete cracked concrete, post installed rebar

Cracked and non-cracked concrete

Natural stone

Solid brick

Marble

Wood

product information Characteristics • High performance, rapid curing, two part chemical anchoring system based on a high reactivity Vinylester Styrene Free resin. Applied in one single action this resin will produce a strong, chemical resistant fixing. Features • High bond strength with High load resistance • Used in non-cracked and cracked concrete • Fast gelling and curing • Used in dry and wet concrete • Used in critical or overhead applications • Used in corrosive environments • Used for rebar installations under TR029 • Used for post-installed rebar under TRO23 • Low shrinkage enables large diameter installations • Close edge distance and small spacing • High chemical resistance • Use with potable water WRC water Approval BS 6920 • Fire approved F180 • Eta Option 7 ETAG for uncracked concrete with studs and M8-M24 rebar TR029 Ø8-Ø25 • ETA Option 1 ETAG 001 for cracked concrete with studs M12-M16 • ETA option ETAG 01-01 for post-installed rebar connections TR023 Ø8 to Ø16 mm

Benefit • High performances. Non-flammable and non-hazardous • Styrene free. Very low odor, ideal as well for indoor usage A+ rating • Available in different formats • Cartridge can be used up to the end of the validity date by replacing the static mixer or releasing cartridge with the sealing cap Suggestion for use • Performance based on clean holes. HAMMER DRILLED – blown and then brushed with a stiff metal brush and blown again.

installation sequence Solid brick

Code

1008 1120 1160

Description

CV. VSF PRO 345 CE CV. VSF PRO 400 CE CV. VSF PRO 300 CE

Content

Gun to be used

345 400 300

side by side coaxial silicone

24


chemical anchors

Vorpa CV.VSF CE PRO

Vinylester styrene free chemical anchor with European Technical Approval for non-cracked concrete cracked concrete, post installed rebar

Cracked and non-cracked concrete

Natural stone

Solid brick

Marble

Wood

technical data Minimum Curing Time

Temperature Ranges

Concrete Temperature

Gel-working Time

-10°C * -5°C * 5°C 15°C 25°C 35°C

50 min 40 min 20 min 9 min 5 min 3 min

Minimum curing time Minimum curing time in dry concrete in wet concrete

240 min 180 min 90 min 60 min 30 min 20 min

x2 x2 x2 x2 x2 x2

Compressive Strength Flexural Strength Flexural Modulus Tensile Strength E Modulus VOC Content

Concrete Service Temperature

Range I Range II

-40°C to +40°C -40°C to +80°C

Maximum Long Term Maximum Short Term Concrete Temp Concrete Temp

+40°C +80°C

+24°C +50°C

Service temperature range: Range of ambient temperatures after installation and during the lifetime of the anchor. Short term temperature: Temperature within the service temperature range which vary over short intervals, e.g. day/night cycles and freeze/than cycles. Long term temperature: Temperature, within the service temperature range, which will be approximately constant over significant periods of time.

* Resin temperature must be at least 20°C - Full cure 24 hours - All specifications based on supplied mixer Physical Properties

Temperature Range

N/mm2 (MPa)

Test Method

73,0 25,0 3850,0 14,6 8029,7 A+

EN ISO 604 / ASTM 695 EN ISO 178 / ASTM 790 EN ISO 178 / ASTM 790 EN ISO 527 / ASTM 638 EN ISO 527 / ASTM 638 -

Loads, Edge and Spacings based on Characteristic bond strengths - Showing steel failure with 5.8 grade studding and associated installation data Characteristic Resistance (kN) Ø mm

8

10

12

16

20

24

27

30

33

36

Tension (Nrk) 19,00 19,00 19,00 22,62 30,20 30,20 29,82 43,80 43,80 43,43 67,86 81,60 55,42 104,68 127,40 63,33 133,00 183,60 70,91 154,72 238,00 78,04 182,09 292,00 88,95 205,27 360,00 108,57 246,10 425,00

Shear (Vrk)

9,00

15,00

21,00

39,00

61,00

88,00

115,00

142,50

173,50

212,50

Design Resistance (kN)

Recommended Load (kN)

Characteristic distances (mm)

Tension (Nrd)

Tension (Nrec)

Shear (Vrec)

Edge (Ncr,N)

Spacing (Scr,N)

5,14

80

8,57

12,70 12,70 12,70 15,08 20,10 20,10 19,88 29,20 29,20 28,95 45,24 54,40 36,95 69,79 84,90 42,22 88,67 122,40 47,27 103,15 159,10 52,02 121,39 194,50 59,30 136,85 240,60 72,38 164,07 283,33

Shear (Vrd)

7,20

12,00

16,80

31,20

48,80

70,40

92,00

114,00

138,80

170,00

9,07 9,07 9,07 10,77 14,36 14,36 14,20 20,86 20,86 20,68 32,31 38,86 26,39 49,85 60,64 30,16 63,33 87,43 33,77 73,68 113,64 37,16 86,71 138,93 42,36 97,75 171,86 51,70 117,19 202,38

Min Edge and Spacing

Nominal Embedment

Edge (Ccr,V)

(mm) (Cmin Smin)

(mm)

160

80

40

100

200

90

50

12,00

120

240

110

60

22,29

160

320

125

80

34,86

200

400

180

100

50,29

230

460

220

120

65,71

270

540

240

135

81,43

280

560

280

150

121,43

310

620

310

165

121,43

330

660

330

180

All data is based on correct installation - see instructions Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d

25

60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 110 240 540 120 280 600 130 300 660 150 340 720

Hole Hole Max diameter diameter Torque concrete fixture (mm)

(mm)

(Nm)

10

9

10

12

12

20

14

14

40

18

18

80

24

22

120

28

26

160

32

30

180

35

32

200

37

36

250

40

38

300

= steel failure


chemical anchors

Vorpa CV.VSF CE PRO

Vinylester styrene free chemical anchor with European Technical Approval for non-cracked concrete cracked concrete, post installed rebar

Cracked and non-cracked concrete

Natural stone

Solid brick

Marble

Wood

hef

Fd,s

technical data Design resistance of resin with various stud strenghts and rebar 5.8 grade steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30 33 36

10 12 14 18 24 28 32 35 38 40

depth mm

failure

60 70 80 90 12.7 15.1 17.6 20.1 19.9 22.7 25.6 29.0 32.6 32.8 36.9

60

70

80

90

100

110

28.4 36.2 41.1 42.2

29,2 39.8 45.2 46.5 47.3

100

110

120

130

140

160

200

240

280

320

400

43.4 49.3 50.7 51.6 52.0

47.1 53.4 54.9 55.9 56.4 59.3

120

130

50.7 57.5 59.1 60.2 60.7 63.9 67.6 140

54.4 65.7 67.6 68.8 69.4 73.0 77.2 160

82.1 84.5 86.0 86.7 91.2 96.5 200

84.9 101.3 103.2 104.1 109.5 115.8 240

118.2 120.3 121.4 127.7 135.1 280

122.4 137.5 138.8 146.0 154.4 320

159.1 173.4 182.5 193.0 400

480

540

600

660

720

194.5 219.0 240.6 231.6 260.6 283.2 480 540 600 660

720

design load

(mm)

(kN)

59 80 103 150 207 290 370 449 527 587

12.7 20.1 29.2 54.4 84.9 122.4 159.1 194.5 240.6 283.2

hef

Fd,s

8.8 grade steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30 33 36

10 12 14 18 24 28 32 35 38 40

depth mm

failure

60 70 80 12.9 15.0 17.2 15.1 17.6 20.1 19.9 22.7 29.0 32.8

60

70

80

90 19.3 22.6 25.6 32.6 36.9

90

100 19.5 25.1 28.4 36.2 41.1 42.2

100

110

120

130

27.6 31.2 39.8 45.2 46.5 47.3

30.2 34.1 43.4 49.3 50.7 51.6 52.0

30.9 36.9 47.1 53.4 54.9 55.9 56.4 59.3

120

130

110

140

160

200

240

280

320

400

480

540

39.8 50.7 57.5 59.1 60.2 60.7 63.9 67.6 140

45.0 57.9 65.7 67.6 68.8 69.4 73.0 77.2 160

72.4 82.1 84.5 86.0 86.7 91.2 96.5 200

83.7 98.5 101.3 103.2 104.1 109.5 115.8 240

114.9 118.2 120.3 121.4 127.7 135.1 280

130.7 135.1 137.5 138.8 146.0 154.4 320

168.9 171.9 173.4 182.5 193.0 400

188.3 206.3 208.1 219.0 231.6 480

232.1 234.1 246.4 260.6 540

600

660

720

260.2 273.7 301.1 289.5 318.5 347.4 600 660 720

design load

(mm)

(kN)

91 123 158 231 318 446 570 690 811 903

19.5 30.9 45.0 83.7 130.7 188.3 244.8 299.2 370.1 435.7

hef

Fd,s

10.9 grade steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30 33 36

10 12 14 18 24 28 32 35 38 40

depth mm

failure

60 70 80 12.9 15.0 17.2 15.1 17.6 20.1 19.9 22.7 29.0 32.8

60

70

80

90 19.3 22.6 25.6 32.6 36.9

90

100 21.4 25.1 28.4 36.2 41.1 42.2

110 23.6 27.6 31.2 39.8 45.2 46.5 47.3

120 25.7 30.2 34.1 43.4 49.3 50.7 51.6 52.0

130 27.2 32.7 36.9 47.1 53.4 54.9 55.9 56.4 59.3

100

110

120

130

140

160

200

240

280

320

400

480

35.2 39.8 50.7 57.5 59.1 60.2 60.7 63.9 67.6 140

40.2 45.4 57.9 65.7 67.6 68.8 69.4 73.0 77.2 160

43.1 56.8 72.4 82.1 84.5 86.0 86.7 91.2 96.5 200

62.6 86.9 98.5 101.3 103.2 104.1 109.5 115.8 240

101.3 114.9 118.2 120.3 121.4 127.7 135.1 280

115.8 131.4 135.1 137.5 138.8 146.0 154.4 320

116.6 164.2 168.9 171.9 173.4 182.5 193.0 400

202.7 206.3 208.1 219.0 231.6 480

26

540

600

660

720

(mm)

127 171 220 322 443 621 793 232.1 961 234.1 260.2 1130 246.4 273.7 301.1 260.6 289.5 318.5 347.4 1258 540 600 660 720

design load

(kN)

27.2 43.1 62.6 116.6 182.0 262.2 341.0 416.7 515.5 606.9


chemical anchors

Vorpa CV.VSF CE PRO

Vinylester styrene free chemical anchor with European Technical Approval for non-cracked concrete cracked concrete, post installed rebar

Cracked and non-cracked concrete

Natural stone

Solid brick

Marble

Wood

hef

Fd,s

technical data

A4-70 stainless steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30 33 36

10 12 14 18 24 28 32 35 38 40

depth mm

failure

60 70 80 12.9 13.7 15.1 17.6 20.1 19.9 22.7 29.0 32.8

60

70

80

90

100

110

120

21.7 25.6 28.4 31.2 31.6 32.6 36.2 39.8 43.4 36.9 41.1 45.2 49.3 42.2 46.5 50.7 47.3 51.6 52.0

90

100

110

120

130

140

160

200

47.1 53.4 54.9 55.9 56.4 59.3

50.7 57.5 59.1 60.2 60.7 63.9 67.6 140

57.9 65.7 67.6 68.8 69.4 73.0 77.2 160

58.8 82.1 84.5 80.2 86.7 91.2 96.5 200

130

240

280

320

400

480

540

600

660

720

400

480

540

600

660

720

91.7 101.3 118.2 132.1 98.1 109.5 121 115.8 135.1 143 240 280 320

design load

(mm)

(kN)

64 86 111 162 223 313 187 226 266 296

13.7 21.7 31.6 58.8 91.7 132.1 80.2 98.1 121.3 142.8

hef

Fd,s

High bond reinforcing bars Fyk = 500 N/mm2 Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 25 28 32 36 40

10 12 15 20 25 30 35 40 44 50

depth mm

failure

60 70 80 8.7 10.2 11.7 10.4 12.1 13.8 13.7 15.7 19.3 21.0

60

70

80

90 13.1 15.6 17.6 21.7 23.6

90

100 14.6 17.3 19.6 24.1 26.2 28.3

110 16.0 19.0 21.6 26.5 28.9 31.1 33.4

120 17.5 20.7 23.5 29.0 31.5 33.9 36.4

130 19.0 22.5 25.5 31.4 34.1 36.8 39.5 43.1

140 20.4 24.2 27.4 33.8 36.7 39.6 42.5 46.5 52.3

100

110

120

130

140

160 21.9 27.6 31.4 38.6 42.0 45.2 48.6 53.1 59.7 66.4 160

200

240

280

320

400

500

34.1 39.2 48.3 52.5 56.6 60.7 66.4 74.7 82.9 200

47.1 57.9 63.0 67.9 72.8 79.6 89.6 99.5 240

49.2 67.6 73.5 79.2 85.0 92.9 104.5 116.1 280

77.2 84.0 90.5 97.1 106.2 119.4 132.7 320

105.0 113.1 121.4 132.7 149.3 165.9 400

141.4 151.8 165.9 186.6 207.4 500

27

560

640

720

800

(mm)

150 198 251 362 521 695 882 170.0 1054 185.8 212.3 1188 209.0 238.9 268.8 232.3 265.4 298.6 331.8 1317 560 640 720 800

design load

(kN)

21.9 34.1 49.2 87.4 136.6 196.5 267.8 349.7 443.5 546.3


chemical anchors

Vorpa CV.VSF CE PRO

Vinylester styrene free chemical anchor with European Technical Approval for non-cracked concrete cracked concrete, post installed rebar

Cracked and non-cracked concrete

Natural stone

Solid brick

Marble

Wood

technical data Characteristic and Design Load resistances based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non Cracked Concrete Characteristic Resistance (kN) Ø mm

8

10

12

16

20

24

27

30

33

36

Tension (Nrk)

Shear (Vrk)

19,30 25,74 51,47 22,62 33,93 75,40 29,82 46,86 102,24 43,43 67,86 173,72 55,42 104,68 246,30 63,33 133,00 304,01 70,91 154,72 348,11 78,04 182,09 390,19 88,95 205,27 451,60 108,57 246,10 521,15

9,00

15,00

21,00

39,00

61,00

88,00

115,00

142,50

173,50

212,50

Cracked Concrete

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

12,87 17,16 34,31 15,08 22,62 50,27 19,88 31,24 68,16 28,95 45,24 115,81 36,95 69,79 164,20 42,22 88,67 202,67 47,27 103,15 232,08 52,02 121,39 260,12 59,30 136,85 301,07 72,38 164,07 347,44

Shear (Vrd)

7,20

12,00

16,80

31,20

48,80

70,40

92,00

114,00

138,80

170,00

9,19 12,26 24,51 10,77 16,16 35,90 14,20 22,31 48,69 20,68 32,31 82,72 26,39 49,85 117,29 30,16 63,33 144,76 33,77 73,68 165,77 37,16 86,71 185,80 42,36 97,75 215,05 51,70 117,19 248,17

Characteristic Resistance (kN)

Shear (Vrec)

Tension (Nrk)

Shear (Vrk)

Not applicable

5,14

10,40 15,60 34,68 13,12 20,62 44,98 17,37 27,14 69,50 21,06 39,78 93,60

8,57

12,00

22,29

34,86

15,00

21,00

39,00

61,00

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

Shear (Vrd)

Not applicable 6,94 10,40 23,12 8,75 13,75 29,98 11,58 18,10 46,33 14,04 26,52 62,40

12,00

16,80

31,20

48,80

Nominal Embedment

Shear (Vrec)

Not applicable 4,96 7,43 16,52 6,24 9,82 21,42 8,27 12,93 33,10 10,00 18,94 44,59

8,57

12,00

22,29

34,86

50,29 Not applicable

Not applicable

Not applicable

Not applicable

Not applicable

Not applicable

Not applicable

Not applicable

Not applicable

65,71

81,43

99,14

121,43

All data is based on correct installation - see instructions. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C

Bond Strength Factors

Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) non cracked fc= cracked fc=

C15/20

C20/25

C25/30

C30/37

C35/45

C40/50

C45/55

C50/60

0.94 0.96

1.00 1.00

1.06 1.03

1.12 1.05

1.17 1.06

1.23 1.07

1.26 1.08

1.30 1.09

Influence of environmental conditions in non cracked concrete

Temp I 40°C/24°C Temp II 80°C/50°C

Dry and Wet Dry and Wet

M8

M10

M12

M16

M20

M24

M27

M30

M33

M36

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

0.90

0.88

0.87

0.86

0.85

0.84

0.83

0.82

0.81

0.80

Influence of environmental conditions in cracked concrete

Temp I 40°C/24°C Temp II 80°C/50°C

Dry and Wet Dry and Wet

M8

M10

M12

M16

M20

M24

M27

M30

n/a

0.46

0.44

0.40

0.38

n/a

n/a

n/a

n/a

0.45

0.43

0.40

0.38

n/a

n/a

n/a

28

(mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 110 240 540 120 280 600 130 300 660 150 340 720


chemical anchors

Vorpa CV.VSF CE PRO

Vinylester styrene free chemical anchor with European Technical Approval for non-cracked concrete cracked concrete, post installed rebar

Cracked and non-cracked concrete

Natural stone

Solid brick

Marble

Wood

technical data Characteristic and Design Load resistances for REBAR based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non Cracked Concrete Characteristic Resistance (kN) Ø mm

8

10

12

14

16

18

20

22

25

28

32

Tension (Nrk)

Shear (Vrk)

15,68 20,91 41,82 18,66 27,99 62,20 24,70 38,82 84,69 31,67 45,52 110,84 34,74 54,29 138,97 37,55 70,40 168,97 36,76 69,43 163,36 44,92 85,36 197,67 51,05 107,21 255,26 61,08 152,71 305,41 77,21 193,02 386,04

13,95

21,45

31,05

42,45

55,50

69,66

86,55

104,01

135,00

168,75

220,95

Cracked Concrete

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

Shear (Vrd)

8,71 11,62 23,23 10,37 15,55 34,56 13,72 21,56 47,05 17,59 25,29 61,58 19,30 30,16 77,21 20,86 39,11 93,87 20,42 38,57 90,76 24,96 47,42 109,82 28,36 59,56 141,81 33,93 84,84 169,67 42,89 107,23 214,47

9,30

14,30

20,70

28,30

37,00

46,44

57,70

69,34

90,00

112,50

147,30

6,22 8,30 16,60 7,41 11,11 24,68 9,80 15,40 33,61 12,57 18,06 43,98 13,79 21,54 55,15 14,90 27,94 67,05 14,59 27,55 64,83 17,83 33,87 78,44 20,26 42,54 101,29 24,24 60,60 121,20 30,64 76,60 153,19

Characteristic Resistance (kN)

Shear (Vrec)

Tension (Nrk)

Shear (Vrk)

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

Shear (Vrd)

Nominal Embedment

Shear (Vrec)

6,64 Not applicable

Not applicable

Not applicable

10,21 10,56 16,59 36,19 13,72 19,73 48,03 15,28 23,88 61,12 16,51 30,96 74,31 19,79 37,39 87,96 24,19 45,96 106,44 27,49 57,73 137,45

14,79

20,21

26,43

33,17

41,21

49,53

64,29

31,05

42,45

55,50

69,66

86,55

104,00

135,00

5,86 9,22 20,11 7,62 10,96 26,68 8,49 13,26 33,96 9,17 17,20 41,28 11,00 20,77 48,87 13,44 25,53 59,13 15,27 32,07 76,36

20,70

28,10

37,00

46,44

57,70

69,34

90,00

4,19 6,58 14,36 5,45 7,83 19,06 6,06 9,47 24,26 6,55 12,29 29,49 7,85 14,84 34,91 9,60 18,24 42,24 10,91 22,91 54,54

14,79

20,07

26,43

33,17

41,21

49,53

64,29

80,36 Not applicable

Not applicable

Not applicable

105,21

All data is based on correct installation - see instructions. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C

Bond Strength Factors - REBAR Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) non cracked fc= cracked fc=

C15/20

C20/25

C25/30

C30/37

C35/45

C40/50

C45/55

C50/60

0.94 0.96

1.00 1.00

1.06 1.03

1.12 1.05

1.17 1.06

1.23 1.07

1.26 1.08

1.30 1.09

Influence of environmental conditions in non cracked concrete

Temp I 40°C/24°C Temp II 80°C/50°C

Dry and Wet Dry and Wet

Ø8

Ø 10

Ø 12

Ø 14

Ø 16

Ø 18

Ø 20

Ø 22

Ø 25

Ø 28

Ø 32

1.00

1.00

1.00

1.00

1.00

1.00

1.00

0.53

1.00

1.00

1.00

0.90

0.90

0.88

0.88

0.88

0.86

0.86

0.56

0.86

0.84

0.84

29

(mm) 60 80 160 60 90 200 70 110 240 80 115 280 80 125 320 80 150 360 90 170 400 100 190 440 100 210 500 112 280 560 128 320 640


chemical anchors

Vorpa CV.VSF CE PRO

Vinylester styrene free chemical anchor with European Technical Approval for non-cracked concrete cracked concrete, post installed rebar

Cracked and non-cracked concrete

Natural stone

Solid brick

Marble

Wood

technical data Influence of environmental conditions in cracked concrete

Temp I 40°C/24°C Temp II 80°C/50°C

Dry and Wet Dry and Wet

Ø8

Ø 10

Ø 12

Ø 14

Ø 16

Ø 18

Ø 20

Ø 22

Ø 25

Ø 28

Ø 32

n/a

n/a

0.50

0.43

0.50

0.43

0.50

0.53

0.50

n/a

n/a

n/a

n/a

0.44

0.38

0.44

0.38

0.43

0.46

0.43

n/a

n/a

Effect of anchor spacing - Tension Anchor spacing (mm) 40 50 60 70 80 90 100 120 150 160 180 200 225 240 250 275 280 300 320 350 400 440 460 500 540 560 620 660 720

Effect of edge distance - Tension Edge distance (mm) 40 50 60 70 80 90 100 110 120 140 160 180 200 220 240 270 280 310 330 360

Stud/Rebar diameter 8 0,64 0,67 0,70 0,73 0,76 0,79 0,82 0,87 0,96 1,00

10 0,63 0,65 0,67 0,69 0,72 0,74 0,79 0,86 0,88 0,93 1,00

12

0,63 0,64 0,66 0,68 0,70 0,74 0,80 0,82 0,86 0,90 0,95 1,00

16

0,63 0,64 0,65 0,68 0,73 0,74 0,77 0,80 0,84 0,86 0,87 0,91 0,92 0,95 1,00

20

0,63 0,65 0,68 0,70 0,72 0,74 0,77 0,79 0,80 0,83 0,84 0,86 0,88 0,92 1,00

24

0,63 0,65 0,66 0,68 0,69 0,72 0,73 0,74 0,76 0,77 0,79 0,81 0,83 0,88 0,92 1,00

27

0,64 0,65 0,65 0,67 0,69 0,71 0,72 0,74 0,75 0,76 0,78 0,81 0,86 0,89 0,91 0,95 1,00

30

0,63 0,63 0,65 0,66 0,68 0,69 0,70 0,72 0,73 0,74 0,76 0,78 0,82 0,85 0,87 0,90 0,93 1,00

33

0,62 0,64 0,65 0,67 0,69 0,70 0,72 0,72 0,74 0,75 0,78 0,82 0,85 0,87 0,90 0,93 0,95 1,00

36

0,64 0,65 0,67 0,68 0,68 0,70 0,70 0,72 0,73 0,75 0,78 0,81 0,82 0,85 0,88 0,89 0,93 1,00

40

0,63 0,64 0,65 0,66 0,67 0,68 0,69 0,69 0,71 0,72 0,73 0,76 0,79 0,80 0,82 0,84 0,86 0,89 0,91 1,00

Stud/Rebar diameter 8 0,64 0,73 0,82 0,90 1,00

10 0,63 0,70 0,77 0,84 0,91 1,00

12

0,63 0,68 0,74 0,80 0,86 0,92 1,00

16

0,63 0,67 0,71 0,76 0,80 0,89 1,00

20

0,63 0,66 0,70 0,77 0,84 0,91 1,00

24

0,64 0,67 0,72 0,78 0,84 0,89 1,00

27

30

0,63 0,70 0,75 0,81 0,86 0,92 1,00

0,63 0,65 0,66 0,76 0,81 0,86 0,94 1,00

27

30

0,44 0,57 0,69 0,82 0,94 1,00

0,30 0,35 0,46 0,57 0,68 0,78 1,00

33

0,62 0,70 0,76 0,81 0,86 0,94 0,97 1,00

36

40

0,67 0,78 0,82 0,87 0,93 0,96 0,98 1,00

0,68 0,71 0,75 0,78 0,83 0,85 0,90 0,93 1,00

36

40

Effect of edge distance - Shear Edge distance (mm) 40 50 60 70 80 90 100 110 125 140 160 180 200 220 240 280 310 330 360

30

Stud/Rebar diameter 8 0,25 0,44 0,63 0,81 1,00

10 0,30 0,48 0,65 0,83 1,00

12

0,30 0,44 0,58 0,72 0,86 1,00

16

20

24

0,40 0,53 0,67 0,35 0,80 0,44 1,00 0,58 0,35 0,72 0,46 0,91 0,62 1,00 0,77 0,92 1,00

33

0,34 0,41 0,50 0,59 0,68 0,86 1,00

0,33 0,42 0,51 0,60 0,78 0,91 1,00

0,32 0,53 0,59 0,72 0,82 0,89 1,00


chemical anchors

Vorpa CV.ESF CE

Epoxy acrylate styrene free chemical anchor with European Technical Approval injection anchor for use in masonry - Approval Option 7 pending products group

Concrete

Natural stone

Wood

Solid brick

Suitable • concrete • natural stone • wood • solid brick • marble • hollow brick • solid brick • perforated cement

CV.ESF 825 CE

ETAG 029 For masonry & Hollow Walls Use category c, w/d Size M10 Steel elements according to Table 2 Annex 5 of ETA-11/0032

ETAG 001-05 option 7 M8-M16 non cracked concrete pending

CV.ESF 300 CE CV.ESF 410 CE

Tested for LEED compliancy

CV.ESF 165 CE

31

Styrene Free

Marble

Hollow brick

Perforated brick

Perforated cement

To fix • heavy duty metal structures • heavy duty structural works • construction joints • scaffolding links • wall ties, starter bars, studs, bolts & large screws


chemical anchors

Vorpa CV.ESF CE

Epoxy acrylate styrene free chemical anchor with European Technical Approval injection anchor for use in masonry - Approval Option 7 pending product information

Concrete

Characteristics • High performance, rapid curing, two part chemical anchoring system based on Epoxy Acrylate Styrene Free resin. Applied in one single action this resin will produce a cost effective, strong, chemical resistant fixing. Benefits • ETA approval for use in masonry M10 • ETA approval for use in non concrete opt.7 pending • Chemical corrosion resistant • Ideal to be used with reinforcing bars • Suitable for close edge applications, no tension on base material • Suitable for high load applications on concrete, natural stone and solid brick • High loading values at reduced embedment depths • Easy to be extruded granting quicker working times • High performances. Non-flammable and non-hazardous • Styrene free. Very low odor, ideal as well for indoor usage A+rating • Available in different formats

Natural stone

Wood

Hollow brick

1114 1002E 1110 1111

CV. ESF 825 CE CV. ESF 410 CE CV. ESF 300 CE CV. ESF 165 CE

Hollow brick

Perforated brick

Perforated cement

Suggestion for use • Performance based on clean holes. HAMMER DRILLED – blown and then brushed with a stiff metal brush and blown again.

Solid brick

Description

Marble

Characteristics • Cartridge can be used up to the end of the validity date by replacing the static mixer or releasing cartridge with the sealing cap • Fast celling and curing • Used in dry and wet concrete • Extremely versatile

installation sequence

Code

Solid brick

Content ml

Gun to be used

825 410 300 165

side by side coaxial silicone silicone

32


chemical anchors

Vorpa CV.ESF CE

Epoxy acrylate styrene free chemical anchor with European Technical Approval injection anchor for use in masonry - Approval Option 7 pending technical data

Concrete

Minimum Curing Time Gel-working Time

-10°C * -5°C * 5°C 15°C 25°C 35°C

40 min 40 min 15 min 8 min 5 min 3 min

Minimum curing time Minimum curing time in dry concrete in wet concrete

x2 x2 x2 x2 x2 x2

240 min 240 min 120 min 60 min 45 min 30 min

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

Temperature Range

Concrete Service Temperature

Range I Range II

-40°C to +40°C -40°C to +60°C

Maximum Long Term Maximum Short Term Concrete Temp Concrete Temp

+24°C +50°C

+40°C +80°C

Service temperature range: Range of ambient temperatures after installation and during the lifetime of the anchor. Short term temperature: Temperature within the service temperature range which vary over short intervals, e.g. day/night cycles and freeze/than cycles. Long term temperature: Temperature, within the service temperature range, which will be approximately constant over significant periods of time.

* Resin temperature must be at least 20°C - Full cure 24 hours - All specifications based on supplied mixer

Compressive Strength Flexural Strength Flexural Modulus Tensile Strength E Modulus VOC Content

Wood

Temperature Ranges

Concrete Temperature

Physical Properties

Natural stone

N/mm2 (MPa)

Test Method

45 15,4 3111,7 9,4 5488,5 A+

EN ISO 604 / ASTM 695 EN ISO 178 / ASTM 790 EN ISO 178 / ASTM 790 EN ISO 527 / ASTM 638 EN ISO 527 / ASTM 638 -

Loads, Edge and Spacings based on Characteristic bond strengths - Showing steel failure with 5.8 grade studding Characteristic Resistance (kN) Ø mm

8

10

12

16

20

24

30

Tension (Nrk) 17,79 19,00 19,00 20,81 30,20 30,20 27,45 43,13 43,80 39,97 62,46 81,60 50,89 96,13 127,40 58,28 122,39 183,60 71,82 167,57 292,00

Shear (Vrk)

9,00

15,00

21,00

39,00

61,00

88,00

142,50

Design Resistance (kN)

Recommended Load (kN)

Characteristic distances (mm)

Tension (Nrd)

Tension (Nrec)

Shear (Vrec)

Edge (Ncr,N)

Spacing (Scr,N)

5,14

80

8,57

9,88 12,70 12,70 11,56 20,10 20,10 15,25 23,96 29,20 22,21 34,70 54,40 28,27 53,41 84,90 32,38 68,00 122,40 39,90 93,10 194,50

Shear (Vrd)

7,20

12,00

16,80

31,20

48,80

70,40

114,00

7,06 9,07 9,07 8,26 14,36 14,36 10,89 17,11 20,86 15,86 24,78 38,86 20,20 38,15 60,64 23,13 48,57 87,43 28,50 66,50 138,93

Min Edge and Spacing

Nominal Embedment

Edge (Ccr,V)

(mm) (Cmin Smin)

(mm)

160

80

40

100

200

90

50

12,00

120

240

110

60

22,29

160

320

125

80

34,86

200

400

180

100

50,29

240

480

220

120

81,43

280

560

280

150

All data is based on correct installation - see instructions No influence of edge and spacing Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C

33

60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 110 280 600

Hole Hole Max diameter diameter Torque concrete fixture (mm)

(mm)

(Nm)

10

9

10

12

12

20

14

14

40

18

18

80

24

22

120

28

26

160

35

32

200

= Steel failure


chemical anchors

Vorpa CV.ESF CE

Epoxy acrylate styrene free chemical anchor with European Technical Approval injection anchor for use in masonry - Approval Option 7 pending technical data

Concrete

Natural stone

Design resistance of resin with various stud strenghts and rebar

Wood

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

= Steel failure

5.8 grade steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30

10 12 14 18 24 28 32 35

depth mm

hef failure

embedment depth 60 7.3 8.1

60

70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2

70

80

90

100 12.1 13.5 15.5 19.3 22.4 22.6

110 12.7 14.9 17.0 21.2 24.7 24.9 26.1

100

110

120 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120

130 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130

140 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140

160 20.1 24.7 30.9 35.9 36.2 38.0 37.7 160

200 29.2 38.6 44.9 45.2 47.5 47.1 200

240

46.3 53.8 54.3 57.0 56.6 240

280

54.1 62.8 63.3 66.5 66.0 280

320

54.4 71.8 72.4 76.0 75.4 320

400

480

540

600

660

84.9 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660

720

Fd,s design load

(mm)

(kN)

105 148 189 282 379 541 670 825

12.7 20.1 29.2 54.4 84.9 122.4 159.1 194.5

hef

Fd,s

720

8.8 grade steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30

10 12 14 18 24 28 32 35

depth mm

failure

embedment depth 60 7.3 8.1

60

70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2

70

80

90

100 12.1 13.5 15.5 19.3 22.4 22.6

110 13.3 14.9 17.0 21.2 24.7 24.9 26.1

100

110

120 14.5 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120

130 15.8 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130

140 17.0 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140

160 19.5 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160

200 27.1 30.9 38.6 44.9 45.2 47.5 47.1 200

240 37.1 46.3 53.8 54.3 57.0 56.6 240

280

54.1 62.8 63.3 66.5 66.0 280

320

61.8 71.8 72.4 76.0 75.4 320

400

480

540

600

660

89.7 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660

720

design load

(mm)

(kN)

161 228 291 434 582 832 1031 1270

19.5 30.9 45.0 83.7 130.7 188.3 244.8 299.2

hef

Fd,s

720

10.9 grade steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30

10 12 14 18 24 28 32 35

depth mm

failure

embedment depth 60 7.3 8.1

60

70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2

70

80

90

100 12.1 13.5 15.5 19.3 22.4 22.6

110 13.3 14.9 17.0 21.2 24.7 24.9 26.1

100

110

120 14.5 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120

130 15.8 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130

140 17.0 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140

160 19.4 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160

200 27.1 30.9 38.6 44.9 45.2 47.5 47.1 200

240 37.1 46.3 53.8 54.3 57.0 56.6 240

280

54.1 62.8 63.3 66.5 66.0 280

320

61.8 71.8 72.4 76.0 75.4 320

400

480

540

600

660

89.7 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660

720

design load

(mm)

(kN)

224 318 405 604 811 1159 1435 1768

27.2 43.1 62.6 116.6 182.0 262.2 341.0 416.7

hef

Fd,s

720

A4-70 grade steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30

10 12 14 18 24 28 32 35

depth mm

failure

embedment depth 60 7.3 8.1

60

70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2

70

80

90

100 12.1 13.5 15.5 19.3 22.4 22.6

100

110 13.3 14.9 17.0 21.2 24.7 24.9 26.1 110

120 13.7 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120

130 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130

140 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140

160 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160

200 30.9 38.6 44.9 45.2 47.5 47.1 200

*1 = tensile strenght 500N/mm2

34

240 31.6 46.3 53.8 54.3 57.0 56.6 240

280

54.1 62.8 63.3 66.5 66.0 280

320

58.8 71.8 72.4 76.0 75.4 320

400

480

540

89.7 90.5 108.6 80.2 94.3 98.1 400 480 540

600

600

660

660

720

1 1 720

design load

(mm)

(kN)

113 160 204 304 409 584 338 416

13.7 21.7 31.6 58.8 91.7 132.1 80.2 98.1


chemical anchors

Vorpa CV.ESF CE

Epoxy acrylate styrene free chemical anchor with European Technical Approval injection anchor for use in masonry - Approval Option 7 pending technical data

Concrete

Natural stone

Design resistance of resin with various stud strenghts and rebar

Wood

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

Rottura acciaio

Ferri da ripresa Fyk = 500 N/mm2 Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 25 28 32

10 12 15 20 25 30 35 40

depth mm

hef 60 6.3 7.6

60

70 7.4 8.8 9.4

70

80 8.4 10.1 10.8 13.3 14.1

90 9.5 11.4 12.1 14.9 15.8

100 10.6 12.6 13.5 16.6 17.6 18.5

110 11.6 13.9 14.8 18.2 19.4 20.3 21.5

120 12.7 15.2 16.2 19.9 21.1 22.2 23.4

80

90

100

110

120

130 13.7 16.4 17.5 21.6 22.9 24.0 25.4 26.1 130

140 14.8 17.7 18.9 23.2 24.6 25.8 27.3 28.2 140

160 16.9 20.2 21.6 26.5 28.2 29.5 31.2 32.2 160

200

240

25.3 27.0 33.2 35.2 36.9 39.1 40.2 200

32.4 39.8 42.2 44.3 46.9 48.3 240

Fd,s

failure

embedment depth 280

46.5 49.3 51.7 54.7 56.3 280

320

400

53.1 56.3 59.1 62.5 64.3 320

500

560

640

720

70.4 73.8 92.3 78.1 97.7 109.4 80.4 100.5 112.6 128.7 400 500 560 640 720

800

design load

(mm)

(kN)

207 270 364 527 775 1065 1371 1739

21.9 34.1 49.2 87.4 136.6 196.5 267.8 349.7

800

Characteristic and Design Load resistances based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non Cracked Concrete Characteristic Resistance (kN) Ø mm

Tension (Nrk)

Shear (Vrk)

Cracked Concrete

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

Shear (Vrd)

Characteristic Resistance (kN)

Shear (Vrec)

Tension (Nrk)

Shear (Vrk)

17,79 9,89 7,06 23,73 9,00 13,18 7,20 9,41 5,14 Not applicable 47,45 26,36 18,83 20,81 11,56 8,26 10 31,21 15,00 17,34 12,00 12,39 8,57 Not applicable 69,37 38,54 27,53 27,45 15,25 10,89 12 43,13 21,00 23,96 16,80 17,11 12,00 Not applicable 94,10 52,28 37,34 39,97 22,21 15,86 16 62,46 39,00 34,70 31,20 24,78 22,29 Not applicable 159,88 88,82 63,45 50,89 28,27 20,20 20 96,13 61,00 53,41 48,80 38,15 34,86 Not applicable 226,20 125,66 89,76 58,28 32,38 23,13 24 122,39 88,00 68,00 70,40 48,57 50,29 Not applicable 279,76 155,42 111,02 71,82 39,90 28,50 Not applicable 30 167,57 207,00 93,10 165,60 66,50 118,29 359,08 199,49 142,49 All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C 8

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

Not applicable

Not applicable

Not applicable

Not applicable

Not applicable

Not applicable

Not applicable

Not applicable

Not applicable

Not applicable

Not applicable

Not applicable

Not applicable

Influence of concrete strength on combined pull out and concrete cone resistance C15/20

C20/25

C25/30

C30/37

C35/45

C40/50

C45/55

C50/60

0.98

1.00

1.03

1.06

1.09

1.13

1.16

1.20

Influence of environmental conditions in non cracked concrete

Temp I 40°C/24°C Temp II 80°C/50°C

Dry and Wet Dry and Wet

M8

M10

M12

M16

M20

M24

M30

1.00

1.00

1.00

1.00

1.00

1.00

1.00

0.90

0.88

0.87

0.86

0.85

0.84

0.82

35

Shear (Vrec)

Not applicable

Bond Strength Factors

Concrete Strength N/mm2 (Mpa) non cracked fc=

Shear (Vrd)

Nominal Embedment (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600


chemical anchors

Vorpa CV.ESF CE

Epoxy acrylate styrene free chemical anchor with European Technical Approval injection anchor for use in masonry - Approval Option 7 pending technical data

Concrete

Natural stone

Wood

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

Characteristic and Design Load resistances for REBAR based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non Cracked Concrete Characteristic Resistance (kN) Ø mm

8

10

12

14

16

18

20

22

25

28

32

Tension (Nrk)

Shear (Vrk)

15,47 20,63 41,26 18,66 27,99 62,20 23,28 36,58 79,80 29,45 42,34 103,08 32,41 50,64 129,65 33,93 63,62 152,68 36,64 69,22 162,86 42,16 80,10 185,51 45,03 94,56 225,13 62,07 155,17 310,34 72,96 182,40 364,81

13,95

21,45

31,05

42,45

55,50

69,66

86,55

104,01

135,00

168,75

220,95

Cracked Concrete

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

8,60 11,46 22,92 10,37 15,55 34,56 12,93 20,32 44,33 16,36 23,52 57,27 18,01 28,13 72,03 18,85 35,34 84,82 20,36 38,45 90,48 23,42 44,50 103,06 25,01 52,53 125,07 29,56 73,89 147,78 34,74 86,86 173,72

Shear (Vrd)

9,30

14,30

20,70

28,30

37,00

46,44

57,70

69,34

90,00

112,50

147,30

6,14 8,19 16,37 7,41 11,11 24,68 9,24 14,51 31,67 11,69 16,80 40,90 12,86 20,10 51,45 13,46 25,25 60,59 14,54 27,47 64,63 16,73 31,79 73,61 17,87 37,52 89,34 21,11 52,78 105,56 24,82 62,04 124,08

Characteristic Resistance (kN)

Shear (Vrec)

Tension (Nrk)

Shear (Vrk)

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

Shear (Vrd)

Shear (Vrec)

6,64

Not applicable

Not applicable

Not applicable

10,21

Not applicable

Not applicable

Not applicable

14,79

Not applicable

Not applicable

Not applicable

20,21

Not applicable

Not applicable

Not applicable

26,43

Not applicable

Not applicable

Not applicable

33,17

Not applicable

Not applicable

Not applicable

41,21

Not applicable

Not applicable

Not applicable

49,53

Not applicable

Not applicable

Not applicable

64,29

Not applicable

Not applicable

Not applicable

80,36

Not applicable

Not applicable

Not applicable

105,21

Not applicable

Not applicable

Not applicable

All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C

Bond Strength Factors REBAR Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) non cracked fc=

C15/20

C20/25

C25/30

C30/37

C35/45

C40/50

C45/55

C50/60

0.97

1.00

1.03

1.06

1.09

1.12

1.16

1.20

Influence of environmental conditions in non cracked concrete

Temp I 40°C/24°C Temp II 80°C/50°C

Dry and Wet Dry and Wet

Ø8

Ø 10

Ø 12

Ø 14

Ø 16

Ø 18

Ø 20

Ø 22

Ø 25

Ø 28

Ø 32

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

0.90

0.90

0.88

0.88

0.88

0.86

0.86

0.84

0.84

0.84

0.84

36

Nominal Embedment (mm) 60 80 160 60 90 200 70 110 240 80 115 280 80 125 320 80 150 360 90 170 400 100 190 440 100 210 500 112 280 560 128 320 640


chemical anchors

Vorpa CV.ESF CE

Epoxy acrylate styrene free chemical anchor with European Technical Approval injection anchor for use in masonry - Approval Option 7 pending technical data Effect of anchor spacing - Tension Anchor spacing (mm) 40 50 60 70 80 90 100 120 150 160 175 200 225 240 250 275 280 300 320 350 400 440 460 500 560

10 0,63 0,65 0,67 0,69 0,72 0,74 0,79 0,86 0,88 0,92 1,00

12

0,63 0,64 0,66 0,68 0,70 0,74 0,80 0,82 0,85 0,90 0,95 1,00

16

0,63 0,64 0,65 0,68 0,73 0,74 0,76 0,80 0,84 0,86 0,87 0,91 0,92 0,95 1,00

Natural stone

Wood

Effect of edge distance - Tension

Stud/Rebar diameter 8 0,64 0,67 0,70 0,73 0,76 0,79 0,82 0,87 0,96 1,00

Concrete

20

0,63 0,65 0,68 0,70 0,71 0,74 0,77 0,79 0,80 0,83 0,84 0,86 0,88 0,92 1,00

24

0,63 0,65 0,66 0,67 0,69 0,72 0,73 0,74 0,76 0,77 0,79 0,81 0,83 0,88 0,92 1,00

30

0,63 0,63 0,64 0,66 0,68 0,69 0,70 0,72 0,73 0,74 0,76 0,78 0,82 0,85 0,87 0,90 1,00

Edge distance (mm) 40 50 60 70 80 90 100 110 120 140 160 180 200 220 240 280

10 0,63 0,70 0,77 0,84 0,91 1,00

12

0,63 0,68 0,74 0,80 0,86 0,92 1,00

37

16

0,63 0,67 0,71 0,76 0,80 0,89 1,00

Marble

Hollow brick

Perforated brick

Perforated cement

Effect of edge distance - Shear

Stud/Rebar diameter 8 0,64 0,73 0,82 0,90 1,00

Solid brick

20

0,63 0,66 0,70 0,77 0,84 0,91 1,00

24

0,64 0,67 0,72 0,78 0,84 0,89 1,00

30

0,63 0,65 0,70 0,76 0,81 0,86 1,00

Edge distance (mm) 40 50 60 70 80 90 100 110 125 140 160 180 200 220 240 280

Stud/Rebar diameter 8 0,25 0,44 0,63 0,81 1,00

10 0,30 0,48 0,65 0,83 1,00

12

0,30 0,44 0,58 0,72 0,86 1,00

16

20

24

0,40 0,53 0,67 0,35 0,80 0,44 1,00 0,58 0,35 0,72 0,46 0,91 0,62 1,00 0,77 0,92 1,00

30

0,30 0,35 0,46 0,57 0,68 0,78 1,00


chemical anchors

Vorpa CV.PSF CE

ancorante ad iniezione a base poliestere senza stirene con valutazione tecnica europea per uso su murature e calcestruzzo non fessurato products group

CV.PSF 300 CE

Concrete

Natural stone

Wood

Solid brick

Suitable • concrete • natural stone • wood • solid brick • marble • hollow brick • solid brick • perforated cement

Marble

Hollow brick

To fix • non-structural fixings • light metal structures • light structural works • solar panel fixing • scaffolding links • floor reinforcement • construction joints • railings

ETAG 001-05 option 7 M8-M16 non cracked concrete

ETAG 029 For masonry & Hollow Walls Use category c, w/d Size M10 Steel elements according to Table 2 Annex 5 of ETA-11/0511

CV.PSF 410 CE

Test report nr. 276986 del 14/12/2010 on wood substrates

CV.PSF 165 CE

Tested for LEED compliancy

38

Styrene Free

Perforated brick

ropic

Thixot

Perforated cement


chemical anchors

Vorpa CV.PSF CE

ancorante ad iniezione a base poliestere senza stirene con valutazione tecnica europea per uso su murature e calcestruzzo non fessurato product information

Concrete

Characteristics • Rapid curing, two part chemical anchoring system based on unsatured Polyester resin in Styrene Free monomers. Applied in one single action this resin will produce a cost effective, strong, chemical resistant fixing. 300ml and 165ml types can be used with a normal silicone gun. Benefits • ETA Approval as injection anchor for use in masonry and non-cracked concrete • Styrene free. Very low odor, ideal as well for indoor usage A+rating • Chemical corrosion resistant • Suitable for close edge applications, no tension on base material • High performances • Available in different formats • Absolutely no leakage

Natural stone

Wood

Hollow brick

1002P 1124 1129

CV. PSF 410 CE CV. PSF 300 CE CV. PSF 165 CE

Hollow brick

Perforated brick

Perforated cement

Suggestion for use • Performance based on clean holes. HAMMER DRILLED – blown and then brushed with a stiff metal brush and blown again.

Solid brick

Description

Marble

Characteristics • Non-flammable and non-hazardous • Cartridge can be used up to the end of the validity date by replacing the static mixer or releasing cartridge with the sealing cap • For applications on hollow materials use the appropriate perforated sleeves.

installation sequence

Code

Solid brick

Content ml

Gun to be used

410 300 165

co-axial silicone silicone

39


chemical anchors

Vorpa CV.PSF CE

ancorante ad iniezione a base poliestere senza stirene con valutazione tecnica europea per uso su murature e calcestruzzo non fessurato technical data

Concrete

Minimum Curing Time Gel-working Time

-10°C * -5°C * 5°C 15°C 25°C 35°C

50 min 40 min 20 min 9 min 5 min 3 min

Minimum curing time Minimum curing time in dry concrete in wet concrete

x2 x2 x2 x2 x2 x2

240 min 180 min 90 min 60 min 30 min 20 min

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

Temperature Range

Concrete Service Temperature

Range I Range II

-40°C to +40°C -40°C to +80°C

Maximum Long Term Maximum Short Term Concrete Temp Concrete Temp

+24°C +50°C

+40°C +80°C

Service temperature range: Range of ambient temperatures after installation and during the lifetime of the anchor. Short term temperature: Temperature within the service temperature range which vary over short intervals, e.g. day/night cycles and freeze/than cycles. Long term temperature: Temperature, within the service temperature range, which will be approximately constant over significant periods of time.

* Resin temperature must be at least 20°C - Full cure 24 hours - All specifications based on supplied mixer

Compressive Strength Flexural Strength Flexural Modulus Tensile Strength E Modulus VOC Content

Wood

Temperature Ranges

Concrete Temperature

Physical Properties

Natural stone

N/mm2 (MPa)

Test Method

43,5 15,9 2803,0 9,3 4874,5 A+

EN ISO 604 / ASTM 695 EN ISO 178 / ASTM 790 EN ISO 178 / ASTM 790 EN ISO 527 / ASTM 638 EN ISO 527 / ASTM 638 -

Loads, Edge and Spacings based on Characteristic bond strengths - Showing steel failure with 5.8 grade steel studding Characteristic Resistance (kN) Ø mm

8

10

12

16

20

24

30

Tension (Nrk) 15,71 19,00 19,00 17,53 26,30 30,20 23,09 36,29 43,80 33,38 52,15 81,60 43,60 82,35 127,40 49,01 102,92 183,60 61,07 142,50 292,00

Shear (Vrk)

9,00

15,00

21,00

39,00

61,00

88,00

142,50

Design Resistance (kN)

Recommended Load (kN)

Characteristic distances (mm)

Tension (Nrd)

Tension (Nrec)

Shear (Vrec)

Edge (Ncr,N)

Spacing (Scr,N)

5,14

80

8,57

7,27 9,70 12,70 8,12 12,17 20,10 10,69 16,80 29,20 15,45 24,14 54,40 20,18 38,13 84,90 22,69 47,65 122,40 28,27 65,97 194,50

Shear (Vrd)

7,20

12,00

16,80

31,20

48,80

70,40

114,00

5,20 6,93 9,07 5,80 8,70 14,36 7,64 12,00 20,86 11,04 17,25 38,86 14,42 27,23 60,64 16,21 34,03 87,43 20,20 47,12 138,93

Min Edge and Spacing

Nominal Embedment

Edge (Ccr,V)

(mm) (Cmin Smin)

(mm)

160

80

40

100

200

90

50

12,00

120

240

110

60

22,29

160

320

125

80

34,86

200

400

180

100

50,29

225

450

220

120

81,43

260

520

280

150

All data is based on correct installation - see instructions No influence of edge and spacing Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C

40

60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600

Hole Hole Max diameter diameter Torque concrete fixture (mm)

(mm)

(Nm)

10

9

10

12

12

20

14

14

40

18

18

80

24

22

120

28

26

160

35

32

200

= Steel failure


chemical anchors

Vorpa CV.PSF CE

ancorante ad iniezione a base poliestere senza stirene con valutazione tecnica europea per uso su murature e calcestruzzo non fessurato technical data

Concrete

Natural stone

Design resistance of resin with various stud strenghts and rebar

Wood

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

= Steel failure

5.8 grade steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30

10 12 14 18 24 28 32 35

depth mm

hef failure

embedment depth 60 7.3 8.1

60

70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2

70

80

90

100 12.1 13.5 15.5 19.3 22.4 22.6

110 12.7 14.9 17.0 21.2 24.7 24.9 26.1

100

110

120 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120

130 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130

140 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140

160 20.1 24.7 30.9 35.9 36.2 38.0 37.7 160

200 29.2 38.6 44.9 45.2 47.5 47.1 200

240

46.3 53.8 54.3 57.0 58.6 240

280

54.1 62.8 63.3 66.5 66.0 280

320

54.4 71.8 72.4 76.0 75.4 320

400

480

540

600

660

84.9 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660

720

Fd,s design load

(mm)

(kN)

105 148 189 282 379 541 670 825

12.7 20.1 29.2 54.4 84.9 122.4 159.1 194.5

hef

Fd,s

720

8.8 grade steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30

10 12 14 18 24 28 32 35

depth mm

failure

embedment depth 60 7.3 8.1

60

70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2

70

80

90

100 12.1 13.5 15.5 19.3 22.4 22.6

110 13.3 14.9 17.0 21.2 24.7 24.9 26.1

100

110

120 14.5 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120

130 15.8 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130

140 17.0 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140

160 19.5 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160

200 27.1 30.9 38.6 44.9 45.2 47.5 47.1 200

240 37.1 46.3 53.8 54.3 57.0 58.6 240

280

54.1 62.8 63.3 66.5 66.0 280

320

61.8 71.8 72.4 76.0 75.4 320

400

480

540

600

660

89.7 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660

720

design load

(mm)

(kN)

161 228 291 434 582 832 1031 1270

19.5 30.9 45.0 83.7 130.7 188.3 244.8 299.2

hef

Fd,s

720

10.9 grade steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30

10 12 14 18 24 28 32 35

depth mm

failure

embedment depth 60 7.3 8.1

60

70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2

70

80

90

100 12.1 13.5 15.5 19.3 22.4 22.6

110 13.3 14.9 17.0 21.2 24.7 24.9 26.1

100

110

120 14.5 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120

130 15.8 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130

140 17.0 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140

160 19.4 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160

200 27.1 30.9 38.6 44.9 45.2 47.5 47.1 200

240 37.1 46.3 53.8 54.3 57.0 58.6 240

280

54.1 62.8 63.3 66.5 66.0 280

320

61.8 71.8 72.4 76.0 75.4 320

400

480

540

600

660

89.7 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660

720

design load

(mm)

(kN)

224 318 405 604 811 1159 1435 1768

27.2 43.1 62.6 116.6 182.0 262.2 341.0 416.7

hef

Fd,s

720

A4-70 grade steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30

10 12 14 18 24 28 32 35

depth mm

failure

embedment depth 60 7.3 8.1

60

70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2

70

80

90

100 12.1 13.5 15.5 19.3 22.4 22.6

100

110 13.3 14.9 17.0 21.2 24.7 24.9 26.1 110

120 13.7 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120

130 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130

140 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140

160 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160

200 30.9 38.6 44.9 45.2 47.5 47.1 200

*1 = tensile strenght 500N/mm2

41

240 31.6 46.3 53.8 54.3 57.0 56.6 240

280

54.1 62.8 63.3 66.5 66.0 280

320

58.8 71.8 72.4 76.0 75.4 320

400

480

540

89.7 90.5 108.6 80.2 94.3 98.1 400 480 540

600

600

660

660

720

1 1 720

design load

(mm)

(kN)

113 160 204 304 409 584 338 416

13.7 21.7 31.6 58.8 91.7 132.1 80.2 98.1


chemical anchors

Vorpa CV.PSF CE

ancorante ad iniezione a base poliestere senza stirene con valutazione tecnica europea per uso su murature e calcestruzzo non fessurato technical data

Concrete

Natural stone

Design resistance of resin with various stud strenghts and rebar

Wood

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

Rottura acciaio

Ferri da ripresa Fyk = 500 N/mm2 Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 25 28 32

10 12 15 20 25 30 35 40

depth mm

hef 60 6.3 7.6

60

70 7.4 8.8 9.4

70

80 8.4 10.1 10.8 13.3 14.1

90 9.5 11.4 12.1 14.9 15.8

100 10.6 12.6 13.5 16.6 17.6 18.5

110 11.6 13.9 14.8 18.2 19.4 20.3 21.5

120 12.7 15.2 16.2 19.9 21.1 22.2 23.4

80

90

100

110

120

130 13.7 16.4 17.5 21.6 22.9 24.0 25.4 26.1 130

140 14.8 17.7 18.9 23.2 24.6 25.8 27.3 28.2 140

160 16.9 20.2 21.6 26.5 28.2 29.5 31.2 32.2 160

200

240

25.3 27.0 33.2 35.2 36.9 39.1 40.2 200

32.4 39.8 42.2 44.3 46.9 48.3 240

Fd,s

failure

embedment depth 280

46.5 49.3 51.7 54.7 56.3 280

320

53.1 56.3 59.1 62.5 64.3 320

400

500

560

640

720

70.4 73.8 92.3 78.1 97.7 109.4 80.4 100.5 112.6 128.7 400 500 560 640 720

800

design load

(mm)

(kN)

207 270 364 527 776 1065 1371 1739

21.9 34.1 49.2 87.4 136.6 196.5 267.8 349.7

800

technical data Characteristic and Design Load resistances based on characteristic bond strengths for hef 4d (minimum embedment) to 20d - threaded mod Non Cracked Concrete Characteristic Resistance (kN) Ø mm

8

10

12

16

20

24

30

Tension (Nrk) 15,71 20,95 41,90 17,53 26,30 58,43 23,09 36,29 79,17 33,38 52,15 133,51 43,60 82,35 193,77 49,01 102,92 235,24 61,07 142,50 305,36

Shear (Vrk)

9,00

15,00

21,00

39,00

61,00

88,00

142,50

Cracked Concrete

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

7,27 9,70 19,40 8,12 12,17 27,05 10,69 16,80 36,65 15,45 24,14 61,81 20,18 38,13 89,71 22,69 47,65 108,91 28,27 65,97 141,37

Shear (Vrd)

7,20

12,00

16,80

31,20

48,80

70,40

114,00

5,20 6,93 13,86 5,80 8,70 19,32 7,64 12,00 26,18 11,04 17,25 44,15 14,42 27,23 64,08 16,21 34,03 77,79 20,20 47,12 100,98

Shear (Vrec)

Characteristic Resistance (kN) Tension (Nrk)

Shear (Vrk)

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

Shear (Vrd)

Shear (Vrec)

5,14

Not applicable

Not applicable

Not applicable

8,57

Not applicable

Not applicable

Not applicable

12,00

Not applicable

Not applicable

Not applicable

22,29

Not applicable

Not applicable

Not applicable

34,86

Not applicable

Not applicable

Not applicable

50,29

Not applicable

Not applicable

Not applicable

81,43

Not applicable

Not applicable

Not applicable

Nominal Embedment (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600

All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C

42


chemical anchors

Vorpa CV.PSF CE

ancorante ad iniezione a base poliestere senza stirene con valutazione tecnica europea per uso su murature e calcestruzzo non fessurato technical data

Concrete

Natural stone

Wood

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

Characteristic and Design Load resistances for REBAR based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non Cracked Concrete Characteristic Resistance (kN) Ø mm

Tension (Nrk)

Shear (Vrk)

Cracked Concrete

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

Shear (Vrd)

Characteristic Resistance (kN)

Shear (Vrec)

Tension (Nrk)

Shear (Vrk)

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

Shear (Vrd)

Shear (Vrec)

Nominal Embedment (mm)

13,30 6,33 4,52 60 17,73 13.95 8,44 9,30 6,03 6,64 80 Not applicable Not applicable Not applicable 35,47 16,89 12,06 160 15,91 7,58 5,41 60 10 23,86 21,45 11,36 14,30 8,12 10,21 90 Not applicable Not applicable Not applicable 53,03 25,25 18,04 200 19,84 9,45 6,75 70 12 31,18 31,05 14,85 20,70 10,61 14,79 110 Not applicable Not applicable Not applicable 68,04 32,40 23,14 240 27,87 13,27 9,48 80 16 43,54 55,50 20,73 37,00 14,81 26,43 125 Not applicable Not applicable Not applicable 111,47 53,08 37,91 320 32,23 15,35 10,96 90 20 60,88 86,55 28,99 57,30 20,71 41,21 170 Not applicable Not applicable Not applicable 143,26 68,22 48,73 400 38,80 18,48 13,20 100 25 81,48 135,00 38,80 90,00 27,71 64,29 210 Not applicable Not applicable Not applicable 193,99 92,38 65,98 500 46,30 22,05 15,75 112 28 115,76 168,75 55,12 112,50 39,37 80,36 280 Not applicable Not applicable Not applicable 231,52 110,25 78,75 560 54,05 25,74 18,38 128 Not applicable Not applicable Not applicable 32 135,11 220,95 64,34 147,30 45,96 105,22 320 270,23 128,68 91,91 640 All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C 8

Bond Strength Factors - Threaded mod Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) non cracked fc=

C15/20

C20/25

C25/30

C30/37

C35/45

C40/50

C45/55

C50/60

0.97

1.00

1.02

1.04

1.07

1.10

1.12

1.15

Influence of environmental conditions in non cracked concrete

Temp I 40°C/24°C Temp II 80°C/50°C

Dry and Wet Dry and Wet

M8

M10

M12

M16

M20

M24

M30

1.00

1.00

1.00

1.00

1.00

1.00

1.00

0.90

0.88

0.87

0.86

0.85

0.84

0.82

Bond Strength Factors - REBAR Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) non cracked fc=

C15/20

C20/25

C25/30

C30/37

C35/45

C40/50

C45/55

C50/60

0.97

1.00

1.02

1.04

1.07

1.10

1.12

1.15

Influence of environmental conditions in non cracked concrete

Temp I 40°C/24°C Temp II 80°C/50°C

Dry and Wet Dry and Wet

Ø8

Ø 10

Ø 12

Ø 16

Ø 20

Ø 25

Ø 28

Ø 32

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

0.90

0.90

0.88

0.88

0.86

0.86

0.84

0.84

43


chemical anchors

Vorpa CV.PSF CE

ancorante ad iniezione a base poliestere senza stirene con valutazione tecnica europea per uso su murature e calcestruzzo non fessurato technical data Effect of anchor spacing - Tension Anchor spacing (mm) 40 50 60 70 80 90 100 120 150 160 175 200 225 240 250 275 280 300 320 350 400 425 450 480 520

10 0,63 0,65 0,67 0,69 0,72 0,74 0,79 0,86 0,88 0,92 1,00

12

0,63 0,64 0,66 0,68 0,70 0,74 0,80 0,82 0,85 0,90 0,95 1,00

16

0,63 0,64 0,65 0,68 0,73 0,74 0,76 0,80 0,84 0,86 0,87 0,91 0,92 0,95 1,00

Natural stone

Wood

Effect of edge distance - Tension

Stud/Rebar diameter 8 0,64 0,67 0,70 0,73 0,76 0,79 0,82 0,87 0,96 1,00

Concrete

20

0,63 0,65 0,68 0,70 0,71 0,74 0,77 0,79 0,80 0,83 0,84 0,86 0,88 0,92 1,00

24

0,63 0,65 0,66 0,68 0,71 0,74 0,76 0,77 0,80 0,80 0,82 0,85 0,88 0,94 0,97 1,00

30

0,63 0,64 0,65 0,68 0,70 0,72 0,73 0,75 0,76 0,78 0,80 0,83 0,88 0,90 0,93 0,96 1,00

Edge distance (mm) 40 50 60 70 80 90 100 110 120 140 160 180 200 225 250 260

10 0,63 0,70 0,77 0,84 0,91 1,00

12

0,63 0,68 0,74 0,80 0,86 0,92 1,00

16

0,63 0,67 0,71 0,76 0,80 0,89 1,00

Marble

Hollow brick

Perforated brick

Perforated cement

Effect of edge distance - Shear

Stud/Rebar diameter 8 0,64 0,73 0,82 0,90 1,00

Solid brick

20

0,63 0,66 0,70 0,77 0,84 0,91 1,00

24

0,64 0,68 0,76 0,84 0,92 1,00

30

0,63 0,66 0,72 0,78 0,86 0,94 1,00

Edge distance (mm) 40 50 60 70 80 90 100 110 125 140 160 180 200 225 250 280

Stud/Rebar diameter 8 0,25 0,44 0,63 0,81 1,00

10 0,30 0,48 0,65 0,83 1,00

12

0,30 0,44 0,58 0,72 0,86 1,00

16

20

24

0,40 0,53 0,67 0,35 0,80 0,44 1,00 0,58 0,35 0,72 0,45 0,91 0,58 1,00 0,71 0,84 1,00

30

0,30 0,36 0,47 0,59 0,74 0,88 1,00

TECHNICAL DATA FOR APPLICATION ON WOOD Recommended load for applications on glued lamellar wood in conformity with UNI EN 1194 Characteristics of glued lamellar wood UNI EN 1194 Strenght Flexion Parallel Tensile Strenght Perpendicular Tensile Strenght Parallel Compressive Strenght Perpendicular Compressive Strenght Shear Strenght Average Modulus of Elasticity Average Modulus of Shear Volume

N/mm2 fm,k ft,0,k ft,90,k fc,0,k fc,90,k fv,k Eo,mean G mean Pk

Technical data and recommended loads on glued lamellar wood type GL24h Stud size Hole diameter Hole depth (mm) (mm) 80 M8 90 10 M10 100 12 M12 14

GL24 24 16,5 0,4 24 2,7 2,7 11.600 720 380

Test report nr. 276986 del 14/12/2010 on wood substrates

Examples of installation

44

Permissible loads kN 3,3 4,5 8,1


chemical anchors

Vorpa CV.PSF WINTER

Polyester styrene free winter chemical anchor for applications in low ambient temperatures with European Technical Approval opt. 7 for use in non cracked concrete products group

Concrete

Natural stone

Solid brick

Suitable • concrete • natural stone • solid brick • marble • hollow brick • perforated brick • perforated cement

CV.PSF 410 WINTER

Marble

Hollow brick

Perforated brick

Perforated cement

To fix • medium duty metal structures • light structural works • solar panel fixing • construction joints • scaffolding links • railings

WINTER

-10°C

Styrene Free

ETAG 001-05 M8-M16 use in non-cracked concrete

Tested for LEED compliancy

product information Characteristics • High performance, slower curing, two part chemical anchoring system based on unsatured Polyester resin in Styrene Free monomers. Applied in one single action this resin will produce a cost effective, strong, chemical resistant fixing ideal for usage in lower base material temperatures.

Characteristics • Cartridge can be used up to the end of the validity date by replacing the static mixer or releasing cartridge with the sealing cap • For applications on hollow materials use the appropriate perforated sleeves.

Benefits • Ideal for medium duty load applications in low temperature atmosphere, down to -10°C • Styrene free. Very low odor A+ Rating • Chemical corrosion resistant • Suitable for close edge applications, no tension on base material • High performances. Non-flammable and non-hazardous • ETA Approved opt. 7 for use in non cracked concrete

Suggestion for use • Performance based on clean holes. HAMMER DRILLED – blown and then brushed with a stiff metal brush and blown again.

45


chemical anchors

Vorpa CV.PSF WINTER

Polyester styrene free winter chemical anchor for applications in low ambient temperatures with European Technical Approval opt. 7 for use in non cracked concrete installation sequence

Concrete

Natural stone

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

Solid brick

Hollow brick

Code

1168

Description

CV. PSF 410 WINTER

Content ml

Gun to be used

410

co-axial

technical data Minimum Curing Time

Temperature Ranges

Concrete Temperature

Gel-working Time

-20°C* -10°C* -5°C 5°C 15°C 25°C 35°C

70 min 50 min 40 min 20 min 9 min 5 min 3 min

Minimum curing time Minimum curing time in dry concrete in wet concrete

360 min 240 min 180 min 90 min 60 min 30 min 20 min

x2 x2 x2 x2 x2 x2 x2

* Resin temperature must be at least 20°C - Full cure 24 hours - All specifications based on supplied mixer Physical Properties

Compressive Strength Flexural Strength Flexural Modulus Tensile Strength E Modulus VOC Content

N/mm2 (MPa)

Test Method

43,5 15,9 2803 9,3 4874,5 A+

EN ISO 604 / ASTM 695 EN ISO 178 / ASTM 790 EN ISO 178 / ASTM 790 EN ISO 527 / ASTM 638 EN ISO 527 / ASTM 638 -

Temperature Range

Concrete Service Temperature

Range I Range II

-40°C to +40°C -40°C to +80°C

Maximum Long Term Maximum Short Term Concrete Temp Concrete Temp

+24°C +50°C

+40°C +80°C

Service temperature range: Range of ambient temperatures after installation and during the lifetime of the anchor. Short term temperature: Temperature within the service temperature range which vary over short intervals, e.g. day/night cycles and freeze/than cycles. Long term temperature: Temperature, within the service temperature range, which will be approximately constant over significant periods of time.

46


chemical anchors

Vorpa CV.PSF WINTER

Polyester styrene free winter chemical anchor for applications in low ambient temperatures with European Technical Approval opt. 7 for use in non cracked concrete technical data

Concrete

Natural stone

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

Loads, Edge and Spacings based on Characteristic bond strengths - Showing steel failure with 5.8 grade steel studding Characteristic Resistance (kN) Ø mm

8

10

12

16

20

24

30

Tension (Nrk)

Shear (Vrk)

15,71 19,00 19,00 17,53 26,30 30,20 23,09 36,29 43,80 33,38 52,15 81,60 43,60 82,35 127,40 49,01 102,92 183,60 61,07 142,50 292,00

9,00

15,00

21,00

39,00

61,00

88,00

142,50

Design Resistance (kN)

Recommended Load (kN)

Characteristic distances (mm)

Tension (Nrd)

Tension (Nrec)

Shear (Vrec)

Edge (Ncr,N)

Spacing (Scr,N)

5,14

80

8,57

7,27 9,70 12,70 8,12 12,17 20,10 10,69 16,80 29,20 15,45 24,14 54,40 20,18 38,13 84,90 22,69 47,65 122,40 28,27 65,97 194,50

Shear (Vrd)

7,20

12,00

16,80

31,20

48,80

70,40

114,00

5,20 6,93 9,07 5,80 8,70 14,36 7,64 12,00 20,86 11,04 17,25 38,86 14,42 27,23 60,64 16,21 34,03 87,43 20,20 47,12 138,93

Min Edge and Spacing

Nominal Embedment

Edge (Ccr,V)

(mm) (Cmin Smin)

(mm)

160

80

40

100

200

90

50

12,00

120

240

110

60

22,29

160

320

125

80

34,86

200

400

180

100

50,29

225

450

220

120

81,43

260

520

280

150

Hole Hole Max diameter diameter Torque concrete fixture

60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600

(mm)

(mm)

(Nm)

10

9

10

12

12

20

14

14

40

18

18

80

24

22

120

28

26

160

35

32

200

All data is based on correct installation - see instructions No influence of edge and spacing Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C

= Steel failure

technical data Design resistance of resin with various stud strenghts and rebar

= Steel failure

High bond reinforcing bars Fyk = 500 N/mm2 Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 25 28 32

10 12 15 20 25 30 35 40

depth mm

hef failure

embedment depth 60 6.3 7.6

60

70 7.4 8.8 9.4

70

80 8.4 10.1 10.8 13.3 14.1

90 9.5 11.4 12.1 14.9 15.8

100 10.6 12.6 13.5 16.6 17.6 18.5

110 11.6 13.9 14.8 18.2 19.4 20.3 21.5

120 12.7 15.2 16.2 19.9 21.1 22.2 23.4

80

90

100

110

120

130 13.7 16.4 17.5 21.6 22.9 24.0 25.4 26.1 130

140 14.8 17.7 18.9 23.2 24.6 25.8 27.3 28.2 140

160 16.9 20.2 21.6 26.5 28.2 29.5 31.2 32.2 160

200 25.3 27.0 33.2 35.2 36.9 39.1 40.2 200

47

240 32.4 39.8 42.2 44.3 46.9 48.3 240

280

46.5 49.3 51.7 54.7 56.3 280

320

53.1 56.3 59.1 62.5 64.3 320

400

500

560

640

720

70.4 73.8 92.3 78.1 97.7 109.4 80.4 100.5 112.6 128.7 400 500 560 640 720

800

800

Fd,s design load

(mm)

(kN)

207 270 364 527 776 1065 1371 1739

21.9 34.1 49.2 87.4 136.6 196.5 267.8 349.7


chemical anchors

Vorpa CV.PSF WINTER

Polyester styrene free winter chemical anchor for applications in low ambient temperatures with European Technical Approval opt. 7 for use in non cracked concrete technical data

Concrete

Design resistance of resin with various stud strenghts and rebar

Natural stone

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

= Steel failure

5.8 grade steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30

10 12 14 18 24 28 32 35

depth mm

hef failure

embedment depth 60 7.3 8.1

60

70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2

70

80

90

100 12.1 13.5 15.5 19.3 22.4 22.6

110 12.7 14.9 17.0 21.2 24.7 24.9 26.1

100

110

120 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120

130 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130

140 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140

160 20.1 24.7 30.9 35.9 36.2 38.0 37.7 160

200 29.2 38.6 44.9 45.2 47.5 47.1 200

240

46.3 53.8 54.3 57.0 58.6 240

280

54.1 62.8 63.3 66.5 66.0 280

320

54.4 71.8 72.4 76.0 75.4 320

400

480

540

600

660

84.9 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660

720

Fd,s design load

(mm)

(kN)

105 148 189 282 379 541 670 825

12.7 20.1 29.2 54.4 84.9 122.4 159.1 194.5

hef

Fd,s

720

8.8 grade steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30

10 12 14 18 24 28 32 35

depth mm

failure

embedment depth 60 7.3 8.1

60

70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2

70

80

90

100 12.1 13.5 15.5 19.3 22.4 22.6

110 13.3 14.9 17.0 21.2 24.7 24.9 26.1

100

110

120 14.5 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120

130 15.8 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130

140 17.0 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140

160 19.5 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160

200 27.1 30.9 38.6 44.9 45.2 47.5 47.1 200

240 37.1 46.3 53.8 54.3 57.0 58.6 240

280

54.1 62.8 63.3 66.5 66.0 280

320

61.8 71.8 72.4 76.0 75.4 320

400

480

540

600

660

89.7 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660

720

design load

(mm)

(kN)

161 228 291 434 582 832 1031 1270

19.5 30.9 45.0 83.7 130.7 188.3 244.8 299.2

hef

Fd,s

720

10.9 grade steel studding Ø

Ø

Stud

Hole

diameter

diameter

(mm)

(mm)

8 10 12 16 20 24 27 30

10 12 14 18 24 28 32 35

depth mm

failure

embedment depth 60 7.3 8.1

60

70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2

70

80

90

100 12.1 13.5 15.5 19.3 22.4 22.6

110 13.3 14.9 17.0 21.2 24.7 24.9 26.1

100

110

120 14.5 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120

130 15.8 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130

140 17.0 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140

160 19.4 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160

200 27.1 30.9 38.6 44.9 45.2 47.5 47.1 200

240 37.1 46.3 53.8 54.3 57.0 58.6 240

280

54.1 62.8 63.3 66.5 66.0 280

320

61.8 71.8 72.4 76.0 75.4 320

400

480

540

600

660

89.7 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660

720

design load

(mm)

(kN)

224 318 405 604 811 1159 1435 1768

27.2 43.1 62.6 116.6 182.0 262.2 341.0 416.7

hef

Fd,s

720

A4-70 grade steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30

10 12 14 18 24 28 32 35

depth mm

failure

embedment depth 60 7.3 8.1

60

70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2

70

80

90

100 12.1 13.5 15.5 19.3 22.4 22.6

100

110 13.3 14.9 17.0 21.2 24.7 24.9 26.1 110

120 13.7 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120

130 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130

140 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140

160 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160

200 30.9 38.6 44.9 45.2 47.5 47.1 200

*1 = tensile strenght 500N/mm2

48

240 31.6 46.3 53.8 54.3 57.0 56.6 240

280

54.1 62.8 63.3 66.5 66.0 280

320

58.8 71.8 72.4 76.0 75.4 320

400

480

540

89.7 90.5 108.6 80.2 94.3 98.1 400 480 540

600

600

660

660

720

1 1 720

design load

(mm)

(kN)

113 160 204 304 409 584 338 416

13.7 21.7 31.6 58.8 91.7 132.1 80.2 98.1


chemical anchors

Vorpa CV.PSF WINTER

Polyester styrene free winter chemical anchor for applications in low ambient temperatures with European Technical Approval opt. 7 for use in non cracked concrete technical data

Concrete

Natural stone

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

Characteristic and Design Load resistances based on characteristic bond strengths for hef 4d (minimum embedment) to 20d - threaded mod Non Cracked Concrete Characteristic Resistance (kN) Ø mm

8

10

12

16

20

24

30

Tension (Nrk)

Shear (Vrk)

15,71 20,95 41,90 17,53 26,30 58,43 23,09 36,29 79,17 33,38 52,15 133,51 43,60 82,35 193,77 49,01 102,92 235,24 61,07 142,50 305,36

9,00

15,00

21,00

39,00

61,00

88,00

142,50

Cracked Concrete

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

7,27 9,70 19,40 8,12 12,17 27,05 10,69 16,80 36,65 15,45 24,14 61,81 20,18 38,13 89,71 22,69 47,65 108,91 28,27 65,97 141,37

Shear (Vrd)

7,20

12,00

16,80

31,20

48,80

70,40

114,00

5,20 6,93 13,86 5,80 8,70 19,32 7,64 12,00 26,18 11,04 17,25 44,15 14,42 27,23 64,08 16,21 34,03 77,79 20,20 47,12 100,98

Characteristic Resistance (kN)

Shear (Vrec)

Tension (Nrk)

Shear (Vrk)

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

Shear (Vrd)

Shear (Vrec)

5,14

Not applicable

Not applicable

Not applicable

8,57

Not applicable

Not applicable

Not applicable

12,00

Not applicable

Not applicable

Not applicable

22,29

Not applicable

Not applicable

Not applicable

34,86

Not applicable

Not applicable

Not applicable

50,29

Not applicable

Not applicable

Not applicable

81,43

Not applicable

Not applicable

Not applicable

Nominal Embedment (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600

All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C

Bond Strength Factors - Threaded mod Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) non cracked fc=

C15/20

C20/25

C25/30

C30/37

C35/45

C40/50

C45/55

C50/60

0.97

1.00

1.02

1.04

1.07

1.10

1.12

1.15

Influence of environmental conditions in non cracked concrete

Temp I 40°C/24°C Temp II 80°C/50°C

Dry and Wet Dry and Wet

M8

M10

M12

M16

M20

M24

M30

1.00

1.00

1.00

1.00

1.00

1.00

1.00

0.90

0.88

0.87

0.86

0.85

0.84

0.82

49


chemical anchors

Vorpa CV.PSF WINTER

Polyester styrene free winter chemical anchor for applications in low ambient temperatures with European Technical Approval opt. 7 for use in non cracked concrete technical data

Concrete

Natural stone

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

Characteristic and Design Load resistances for REBAR based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non Cracked Concrete Characteristic Resistance (kN) Ø mm

8

10

12

16

20

25

28

32

Tension (Nrk)

Shear (Vrk)

13,30 17,73 35,47 15,91 23,86 53,03 19,84 31,18 68,04 27,87 43,54 111,47 32,23 60,88 143,26 38,80 81,48 193,99 46,30 115,76 231,52 54,05 135,11 270,23

13.95

21,45

31,05

55,50

86,55

135,00

168,75

220,95

Cracked Concrete

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

Shear (Vrd)

6,33 8,44 16,89 7,58 11,36 25,25 9,45 14,85 32,40 13,27 20,73 53,08 15,35 28,99 68,22 18,48 38,80 92,38 22,05 55,12 110,25 25,74 64,34 128,68

9,30

14,30

20,70

37,00

57,30

90,00

112,50

147,30

4,52 6,03 12,06 5,41 8,12 18,04 6,75 10,61 23,14 9,48 14,81 37,91 10,96 20,71 48,73 13,20 27,71 65,98 15,75 39,37 78,75 18,38 45,96 91,91

Characteristic Resistance (kN)

Shear (Vrec)

Tension (Nrk)

Shear (Vrk)

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

Shear (Vrd)

Shear (Vrec)

6,64

Not applicable

Not applicable

Not applicable

10,21

Not applicable

Not applicable

Not applicable

14,79

Not applicable

Not applicable

Not applicable

26,43

Not applicable

Not applicable

Not applicable

41,21

Not applicable

Not applicable

Not applicable

64,29

Not applicable

Not applicable

Not applicable

80,36

Not applicable

Not applicable

Not applicable

105,22

Not applicable

Not applicable

Not applicable

Nominal Embedment (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 500 112 280 560 128 320 640

All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C

Bond Strength Factors - REBAR Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) non cracked fc=

C15/20

C20/25

C25/30

C30/37

C35/45

C40/50

C45/55

C50/60

0.97

1.00

1.02

1.04

1.07

1.10

1.12

1.15

Influence of environmental conditions in non cracked concrete

Temp I 40°C/24°C Temp II 80°C/50°C

Dry and Wet Dry and Wet

Ø8

Ø 10

Ø 12

Ø 16

Ø 20

Ø 25

Ø 28

Ø 32

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

0.90

0.90

0.88

0.88

0.86

0.86

0.84

0.84

50


chemical anchors

Vorpa CV.PSF WINTER

Polyester styrene free winter chemical anchor for applications in low ambient temperatures with European Technical Approval opt. 7 for use in non cracked concrete technical data Effect of anchor spacing - Tension Anchor spacing (mm) 40 50 60 70 80 90 100 120 150 160 175 200 225 240 250 275 280 300 320 350 400 425 450 480 520

10 0,63 0,65 0,67 0,69 0,72 0,74 0,79 0,86 0,88 0,92 1,00

12

0,63 0,64 0,66 0,68 0,70 0,74 0,80 0,82 0,85 0,90 0,95 1,00

16

0,63 0,64 0,65 0,68 0,73 0,74 0,76 0,80 0,84 0,86 0,87 0,91 0,92 0,95 1,00

Natural stone

Effect of edge distance - Tension

Stud/Rebar diameter 8 0,64 0,67 0,70 0,73 0,76 0,79 0,82 0,87 0,96 1,00

Concrete

20

0,63 0,65 0,68 0,70 0,71 0,74 0,77 0,79 0,80 0,83 0,84 0,86 0,88 0,92 1,00

24

0,63 0,65 0,66 0,68 0,71 0,74 0,76 0,77 0,80 0,80 0,82 0,85 0,88 0,94 0,97 1,00

30

0,63 0,64 0,65 0,68 0,70 0,72 0,73 0,75 0,76 0,78 0,80 0,83 0,88 0,90 0,93 0,96 1,00

Edge distance (mm) 40 50 60 70 80 90 100 110 120 140 160 180 200 225 250 260

10 0,63 0,70 0,77 0,84 0,91 1,00

12

0,63 0,68 0,74 0,80 0,86 0,92 1,00

51

16

0,63 0,67 0,71 0,76 0,80 0,89 1,00

Marble

Hollow brick

Perforated brick

Perforated cement

Effect of edge distance - Shear

Stud/Rebar diameter 8 0,64 0,73 0,82 0,90 1,00

Solid brick

20

0,63 0,66 0,70 0,77 0,84 0,91 1,00

24

0,64 0,68 0,76 0,84 0,92 1,00

30

0,63 0,66 0,72 0,78 0,86 0,94 1,00

Edge distance (mm) 40 50 60 70 80 90 100 110 125 140 160 180 200 225 250 280

Stud/Rebar diameter 8 0,25 0,44 0,63 0,81 1,00

10 0,30 0,48 0,65 0,83 1,00

12

0,30 0,44 0,58 0,72 0,86 1,00

16

20

24

0,40 0,53 0,67 0,35 0,80 0,44 1,00 0,58 0,35 0,72 0,45 0,91 0,58 1,00 0,71 0,84 1,00

30

0,30 0,36 0,47 0,59 0,74 0,88 1,00


chemical anchors

Vorpa CV.PSF TROPICAL Polyester styrene free tropical chemical anchor for application in high ambient temperatures.

Concrete

Natural stone

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

products group Suitable • concrete • natural stone • solid brick • marble • hollow brick • perforated brick • perforated cement

CV.PSF TROPICAL 410

Tested for LEED compliancy

To fix • non-structural fixings • light metal works • light structural works • solar panel fixing • scaffolding links • floor reinforcement • construction joints • railings

Styrene Free

product information Characteristics • High performance, slower curing, two part chemical anchoring system based on Polyester Styrene Free resin. Applied in one single action this resin will produce a strong, chemical resistant fixing which can be used at temperatures of up to 45°C.

Characteristics • Cartridge can be used up to the end of the validity date by replacing the static mixer or releasing cartridge with the sealing cap • For applications on hollow materials use the appropriate perforated sleeves.

Benefits • Ideal for medium duty load applications in high temperature atmosphere, up to 45°C • Styrene free. Very low odor A+rating • Chemical corrosion resistant • Suitable for close edge applications, no tension on base material • High performances • Absolutely no leakage • Non-flammable and non-hazardous

Suggestion for use • Performance based on clean holes. HAMMER DRILLED – blown and then brushed with a stiff metal brush and blown again.

52


chemical anchors

Vorpa CV.PSF TROPICAL Polyester styrene free tropical chemical anchor for application in high ambient temperatures.

Concrete

Natural stone

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

installation sequence Solid brick

Hollow brick

Code

1159

Description

CV. PSF TROPICAL

Content ml

Gun to be used

410

co-axial

technical data Temperature Ranges

Minimum Curing Time Concrete Temperature

Gel-working Time

5°C 15°C 25°C 35°C 45°C

45 min 18 min 10 min 5 min 2 min

Minimum curing time Minimum curing time in dry concrete in wet concrete

120 min 75 min 45 min 30 min 15 min

x2 x2 x2 x2 x2

- Full cure 24 hours - All specifications based on supplied mixer

Physical Properties

Compressive Strength Flexural Strength Flexural Modulus Tensile Strength E Modulus VOC Content

N/mm2 (MPa)

Test Method

43,5 15,9 2803,0 9,3 4874,5 A+

EN ISO 604 / ASTM 695 EN ISO 178 / ASTM 790 EN ISO 178 / ASTM 790 EN ISO 527 / ASTM 638 EN ISO 527 / ASTM 638 -

Temperature Range

Concrete Service Temperature

Range I Range II

-40°C to +40°C -40°C to +80°C

Maximum Long Term Maximum Short Term Concrete Temp Concrete Temp

+24°C +50°C

+40°C +80°C

Service temperature range: Range of ambient temperatures after installation and during the lifetime of the anchor. Short term temperature: Temperature within the service temperature range which vary over short intervals, e.g. day/night cycles and freeze/than cycles. Long term temperature: Temperature, within the service temperature range, which will be approximately constant over significant periods of time.

53


chemical anchors

Vorpa CV.PSF TROPICAL Polyester styrene free tropical chemical anchor for application in high ambient temperatures.

Concrete

Natural stone

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

technical data Loads, Edge and Spacings based on Characteristic bond strengths - Showing steel failure with 5.8 grade steel studding Characteristic Resistance (kN) Ø mm

8

10

12

16

20

24

30

Tension (Nrk)

Shear (Vrk)

15,71 19,00 19,00 17,53 26,30 30,20 23,09 36,29 43,80 33,38 52,15 81,60 43,60 82,35 127,40 49,01 102,92 183,60 61,07 142,50 292,00

9,00

15,00

21,00

39,00

61,00

88,00

142,50

Design Resistance (kN)

Recommended Load (kN)

Characteristic distances (mm)

Tension (Nrd)

Tension (Nrec)

Shear (Vrec)

Edge (Ncr,N)

Spacing (Scr,N)

5,14

80

8,57

7,27 9,70 12,70 8,12 12,17 20,10 10,69 16,80 29,20 15,45 24,14 54,40 20,18 38,13 84,90 22,69 47,65 122,40 28,27 65,97 194,50

Shear (Vrd)

7,20

12,00

16,80

31,20

48,80

70,40

114,00

5,20 6,93 9,07 5,80 8,70 14,36 7,64 12,00 20,86 11,04 17,25 38,86 14,42 27,23 60,64 16,21 34,03 87,43 20,20 47,12 138,93

Min Edge and Spacing

Nominal Embedment

Edge (Ccr,V)

(mm) (Cmin Smin)

(mm)

160

80

40

100

200

90

50

12,00

120

240

110

60

22,29

160

320

125

80

34,86

200

400

180

100

50,29

225

450

220

120

81,43

260

520

280

150

Hole Hole Max diameter diameter Torque concrete fixture

60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600

(mm)

(mm)

(Nm)

10

9

10

12

12

20

14

14

40

18

18

80

24

22

120

28

26

160

35

32

200

All data is based on correct installation - see instructions No influence of edge and spacing Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C

= Steel failure

technical data Design resistance of resin with various stud strenghts and rebar

= Steel failure

5.8 grade steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30

10 12 14 18 24 28 32 35

depth mm

hef failure

embedment depth 60 7.3 8.1

60

70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2

70

80

90

100 12.1 13.5 15.5 19.3 22.4 22.6

110 12.7 14.9 17.0 21.2 24.7 24.9 26.1

100

110

120 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120

130 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130

140 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140

160 20.1 24.7 30.9 35.9 36.2 38.0 37.7 160

200 29.2 38.6 44.9 45.2 47.5 47.1 200

54

240

46.3 53.8 54.3 57.0 58.6 240

280

54.1 62.8 63.3 66.5 66.0 280

320

54.4 71.8 72.4 76.0 75.4 320

400

480

540

600

660

84.9 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660

720

720

Fd,s design load

(mm)

(kN)

105 148 189 282 379 541 670 825

12.7 20.1 29.2 54.4 84.9 122.4 159.1 194.5


chemical anchors

Vorpa CV.PSF TROPICAL Polyester styrene free tropical chemical anchor for application in high ambient temperatures.

Concrete

Natural stone

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

technical data 8.8 grade steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30

10 12 14 18 24 28 32 35

depth mm

= Steel failure hef failure

embedment depth 60 7.3 8.1

60

70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2

70

80

100 12.1 13.5 15.5 19.3 22.4 22.6

110 13.3 14.9 17.0 21.2 24.7 24.9 26.1

100

110

90

120 14.5 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120

130 15.8 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130

140 17.0 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140

160 19.5 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160

200 27.1 30.9 38.6 44.9 45.2 47.5 47.1 200

240 37.1 46.3 53.8 54.3 57.0 58.6 240

280

54.1 62.8 63.3 66.5 66.0 280

320

61.8 71.8 72.4 76.0 75.4 320

400

480

540

600

660

89.7 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660

720

Fd,s design load

(mm)

(kN)

161 228 291 434 582 832 1031 1270

19.5 30.9 45.0 83.7 130.7 188.3 244.8 299.2

hef

Fd,s

720

10.9 grade steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30

10 12 14 18 24 28 32 35

depth mm

failure

embedment depth 60 7.3 8.1

60

70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2

70

80

100 12.1 13.5 15.5 19.3 22.4 22.6

110 13.3 14.9 17.0 21.2 24.7 24.9 26.1

100

110

90

120 14.5 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120

130 15.8 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130

140 17.0 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140

160 19.4 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160

200 27.1 30.9 38.6 44.9 45.2 47.5 47.1 200

240 37.1 46.3 53.8 54.3 57.0 58.6 240

280

54.1 62.8 63.3 66.5 66.0 280

320

61.8 71.8 72.4 76.0 75.4 320

400

480

540

600

660

89.7 90.5 108.6 95.0 114.0 128.3 94.3 113.1 127.3 141.4 400 480 540 600 660

720

design load

(mm)

(kN)

224 318 405 604 811 1159 1435 1768

27.2 43.1 62.6 116.6 182.0 262.2 341.0 416.7

hef

Fd,s

720

A4-70 grade steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30

10 12 14 18 24 28 32 35

depth mm

failure

embedment depth 60 7.3 8.1

60

70 80 90 8.5 9.7 10.9 9.5 10.8 12.2 10.8 12.4 13.9 15.4 17.4 17.9 20.2

70

80

100 12.1 13.5 15.5 19.3 22.4 22.6

90

100

110 13.3 14.9 17.0 21.2 24.7 24.9 26.1 110

120 13.7 16.3 18.6 23.2 26.9 27.1 28.5 28.3 120

130 17.6 20.1 25.1 29.2 29.4 30.9 30.6 130

140 19.0 21.6 27.0 31.4 31.7 33.3 33.0 140

160 21.7 24.7 30.9 35.9 36.2 38.0 37.7 160

200 30.9 38.6 44.9 45.2 47.5 47.1 200

240 31.6 46.3 53.8 54.3 57.0 56.6 240

280

54.1 62.8 63.3 66.5 66.0 280

320

58.8 71.8 72.4 76.0 75.4 320

400

480

540

89.7 90.5 108.6 80.2 94.3 98.1 400 480 540

600

600

660

660

720

1 1 720

design load

(mm)

(kN)

113 160 204 304 409 584 338 416

13.7 21.7 31.6 58.8 91.7 132.1 80.2 98.1

hef

Fd,s

*1 = tensile strenght 500N/mm2

High bond reinforcing bars = 500 N/mm2 Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 25 28 32

10 12 15 20 25 30 35 40

depth mm

failure

embedment depth 60 6.3 7.6

60

70 7.4 8.8 9.4

70

80 8.4 10.1 10.8 13.3 14.1

90 9.5 11.4 12.1 14.9 15.8

100 10.6 12.6 13.5 16.6 17.6 18.5

110 11.6 13.9 14.8 18.2 19.4 20.3 21.5

120 12.7 15.2 16.2 19.9 21.1 22.2 23.4

80

90

100

110

120

130 13.7 16.4 17.5 21.6 22.9 24.0 25.4 26.1 130

140 14.8 17.7 18.9 23.2 24.6 25.8 27.3 28.2 140

160 16.9 20.2 21.6 26.5 28.2 29.5 31.2 32.2 160

200 25.3 27.0 33.2 35.2 36.9 39.1 40.2 200

55

240 32.4 39.8 42.2 44.3 46.9 48.3 240

280

46.5 49.3 51.7 54.7 56.3 280

320

53.1 56.3 59.1 62.5 64.3 320

400

500

560

640

720

70.4 73.8 92.3 78.1 97.7 109.4 80.4 100.5 112.6 128.7 400 500 560 640 720

800

800

design load

(mm)

(kN)

207 270 364 527 776 1065 1371 1739

21.9 34.1 49.2 87.4 136.6 196.5 267.8 349.7


chemical anchors

Vorpa CV.PSF TROPICAL Polyester styrene free tropical chemical anchor for application in high ambient temperatures.

Concrete

Natural stone

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

technical data Characteristic and Design Load resistances based on characteristic bond strengths for hef 4d (minimum embedment) to 20d - threaded mod Non Cracked Concrete Characteristic Resistance (kN) Ø mm

8

10

12

16

20

24

30

Tension (Nrk)

Shear (Vrk)

15,71 20,95 41,90 17,53 26,30 58,43 23,09 36,29 79,17 33,38 52,15 133,51 43,60 82,35 193,77 49,01 102,92 235,24 61,07 142,50 305,36

9,00

15,00

21,00

39,00

61,00

88,00

142,50

Cracked Concrete

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

7,27 9,70 19,40 8,12 12,17 27,05 10,69 16,80 36,65 15,45 24,14 61,81 20,18 38,13 89,71 22,69 47,65 108,91 28,27 65,97 141,37

Shear (Vrd)

7,20

12,00

16,80

31,20

48,80

70,40

114,00

5,20 6,93 13,86 5,80 8,70 19,32 7,64 12,00 26,18 11,04 17,25 44,15 14,42 27,23 64,08 16,21 34,03 77,79 20,20 47,12 100,98

Characteristic Resistance (kN)

Shear (Vrec)

Tension (Nrk)

Shear (Vrk)

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

Shear (Vrd)

Shear (Vrec)

5,14

Not applicable

Not applicable

Not applicable

8,57

Not applicable

Not applicable

Not applicable

12,00

Not applicable

Not applicable

Not applicable

22,29

Not applicable

Not applicable

Not applicable

34,86

Not applicable

Not applicable

Not applicable

50,29

Not applicable

Not applicable

Not applicable

81,43

Not applicable

Not applicable

Not applicable

Nominal Embedment (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600

All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C

Bond Strength Factors - Threaded mod Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) non cracked fc=

C15/20

C20/25

C25/30

C30/37

C35/45

C40/50

C45/55

C50/60

0.97

1.00

1.02

1.04

1.07

1.10

1.12

1.15

Influence of environmental conditions in non cracked concrete

Temp I 40°C/24°C Temp II 80°C/50°C

Dry and Wet Dry and Wet

M8

M10

M12

M16

M20

M24

M30

1.00

1.00

1.00

1.00

1.00

1.00

1.00

0.90

0.88

0.87

0.86

0.85

0.84

0.82

56


chemical anchors

Vorpa CV.PSF TROPICAL Polyester styrene free tropical chemical anchor for application in high ambient temperatures.

Concrete

Natural stone

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

technical data Characteristic and Design Load resistances for REBAR based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non Cracked Concrete Characteristic Resistance (kN) Ø mm

8

10

12

16

20

25

28

32

Tension (Nrk)

Shear (Vrk)

13,30 17,73 35,47 15,91 23,86 53,03 19,84 31,18 68,04 27,87 43,54 111,47 32,23 60,88 143,26 38,80 81,48 193,99 46,30 115,76 231,52 54,05 135,11 270,23

13.95

21,45

31,05

55,50

86,55

135,00

168,75

220,95

Cracked Concrete

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

Shear (Vrd)

6,33 8,44 16,89 7,58 11,36 25,25 9,45 14,85 32,40 13,27 20,73 53,08 15,35 28,99 68,22 18,48 38,80 92,38 22,05 55,12 110,25 25,74 64,34 128,68

9,30

14,30

20,70

37,00

57,30

90,00

112,50

147,30

4,52 6,03 12,06 5,41 8,12 18,04 6,75 10,61 23,14 9,48 14,81 37,91 10,96 20,71 48,73 13,20 27,71 65,98 15,75 39,37 78,75 18,38 45,96 91,91

Characteristic Resistance (kN)

Shear (Vrec)

Tension (Nrk)

Shear (Vrk)

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

Shear (Vrd)

Shear (Vrec)

6,64

Not applicable

Not applicable

Not applicable

10,21

Not applicable

Not applicable

Not applicable

14,79

Not applicable

Not applicable

Not applicable

26,43

Not applicable

Not applicable

Not applicable

41,21

Not applicable

Not applicable

Not applicable

64,29

Not applicable

Not applicable

Not applicable

80,36

Not applicable

Not applicable

Not applicable

105,22

Not applicable

Not applicable

Not applicable

Nominal Embedment (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 500 112 280 560 128 320 640

All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C

Bond Strength Factors - REBAR Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) non cracked fc=

C15/20

C20/25

C25/30

C30/37

C35/45

C40/50

C45/55

C50/60

0.97

1.00

1.02

1.04

1.07

1.10

1.12

1.15

Influence of environmental conditions in non cracked concrete

Temp I 40°C/24°C Temp II 80°C/50°C

Dry and Wet Dry and Wet

Ø8

Ø 10

Ø 12

Ø 16

Ø 20

Ø 25

Ø 28

Ø 32

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

0.90

0.90

0.88

0.88

0.86

0.86

0.84

0.84

57


chemical anchors

Vorpa CV.PSF TROPICAL Polyester styrene free tropical chemical anchor for application in high ambient temperatures.

Concrete

Natural stone

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

technical data Effect of anchor spacing - Tension Anchor spacing (mm) 40 50 60 70 80 90 100 120 150 160 175 200 225 240 250 275 280 300 320 350 400 425 450 480 520

Effect of edge distance - Tension

Stud/Rebar diameter 8 0,64 0,67 0,70 0,73 0,76 0,79 0,82 0,87 0,96 1,00

10 0,63 0,65 0,67 0,69 0,72 0,74 0,79 0,86 0,88 0,92 1,00

12

0,63 0,64 0,66 0,68 0,70 0,74 0,80 0,82 0,85 0,90 0,95 1,00

16

0,63 0,64 0,65 0,68 0,73 0,74 0,76 0,80 0,84 0,86 0,87 0,91 0,92 0,95 1,00

20

0,63 0,65 0,68 0,70 0,71 0,74 0,77 0,79 0,80 0,83 0,84 0,86 0,88 0,92 1,00

24

0,63 0,65 0,66 0,68 0,71 0,74 0,76 0,77 0,80 0,80 0,82 0,85 0,88 0,94 0,97 1,00

30

0,63 0,64 0,65 0,68 0,70 0,72 0,73 0,75 0,76 0,78 0,80 0,83 0,88 0,90 0,93 0,96 1,00

Edge distance (mm) 40 50 60 70 80 90 100 110 120 140 160 180 200 225 250 260

Effect of edge distance - Shear

Stud/Rebar diameter 8 0,64 0,73 0,82 0,90 1,00

10 0,63 0,70 0,77 0,84 0,91 1,00

12

0,63 0,68 0,74 0,80 0,86 0,92 1,00

58

16

0,63 0,67 0,71 0,76 0,80 0,89 1,00

20

0,63 0,66 0,70 0,77 0,84 0,91 1,00

24

0,64 0,68 0,76 0,84 0,92 1,00

30

0,63 0,66 0,72 0,78 0,86 0,94 1,00

Edge distance (mm) 40 50 60 70 80 90 100 110 125 140 160 180 200 225 250 280

Stud/Rebar diameter 8 0,25 0,44 0,63 0,81 1,00

10 0,30 0,48 0,65 0,83 1,00

12

0,30 0,44 0,58 0,72 0,86 1,00

16

20

24

0,40 0,53 0,67 0,35 0,80 0,44 1,00 0,58 0,35 0,72 0,45 0,91 0,58 1,00 0,71 0,84 1,00

30

0,30 0,36 0,47 0,59 0,74 0,88 1,00


chemical anchors

Vorpa CV.PE

Polyester chemical anchor

Concrete

Natural stone

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

products group Suitable • concrete • natural stone • solid brick • marble • hollow brick • perforated brick • perforated cement

To fix • non-structural fixings • light metal structures • light structural works • solar panel fixing • scaffolding links • floor reinforcement • construction joints • railings

ETAG 029 Use Category:c,w/d size M8, M10, M12 for use in masonry

CV.PE 300 Tested for LEED compliancy

CV.PE 410

59

n° AT-15-6895/2011


chemical anchors

Vorpa CV.PE

Polyester chemical anchor

Concrete

Natural stone

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

product information Characteristics • Rapid curing, two part chemical anchoring system. Applied in one single action this resin will produce a chemical resistant fixing which is cost effective for usage in aerated concrete or hollow wall applications, as well as general purpose. Benefits • Chemical corrosion resistant • Suitable for close edge applications, no tension on base material • High performances • Available in different formats • Absolutely no leakage • Non-flammable

Characteristics • Cartridge can be used up to the end of the validity date by replacing the static mixer or releasing cartridge with the sealing cap • For applications on hollow materials use the appropriate perforated sleeves. Suggestion for use • Performance based on clean holes. HAMMER DRILLED – blown and then brushed with a stiff metal brush and blown again.

installation sequence Solid brick

Hollow brick

Code

Description

Content ml

Gun to be used

1002B 1125

CV. PE 410 CV. PE 300

410 300

co-axial silicone

60


chemical anchors

Vorpa CV.PE

Polyester chemical anchor

Concrete

Natural stone

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

technical data Minimum Curing Time

Temperature Ranges

Concrete Temperature

Gel-working Time

-10°C * -5°C * 5°C 15°C 25°C 35°C

50 min 40 min 20 min 9 min 5 min 3 min

Minimum curing time Minimum curing time in dry concrete in wet concrete

x2 x2 x2 x2 x2 x2

240 min 180 min 90 min 60 min 30 min 20 min

Compressive Strength Flexural Strength Flexural Modulus Tensile Strength E Modulus VOC Content

Concrete Service Temperature

Range I Range II

-40°C to +40°C -40°C to +80°C

Maximum Long Term Maximum Short Term Concrete Temp Concrete Temp

+24°C +50°C

+40°C +80°C

Service temperature range: Range of ambient temperatures after installation and during the lifetime of the anchor. Short term temperature: Temperature within the service temperature range which vary over short intervals, e.g. day/night cycles and freeze/than cycles. Long term temperature: Temperature, within the service temperature range, which will be approximately constant over significant periods of time.

* Resin temperature must be at least 20°C - Full cure 24 hours - All specifications based on supplied mixer Physical Properties

Temperature Range

N/mm2 (MPa)

Test Method

41,8 14,1 2589,6 7,4 4365,5 A+

EN ISO 604 / ASTM 695 EN ISO 178 / ASTM 790 EN ISO 178 / ASTM 790 EN ISO 527 / ASTM 638 EN ISO 527 / ASTM 638 -

Loads, Edge and Spacings based on Characteristic bond strengths - Showing steel failure with 5.8 grade steel studding Characteristic Resistance (kN) Ø mm

8

10

12

16

20

24

30

Tension (Nrk) 14,85 19,00 19,00 16,57 24,85 30,20 21,82 34,29 43,80 31,54 49,28 81,60 41,20 77,82 127,40 46,31 97,26 183,60 57,70 134,66 292,00

Shear (Vrk)

9,00

15,00

21,00

39,00

61,00

88,00

142,50

Design Resistance (kN)

Recommended Load (kN)

Characteristic distances (mm)

Tension (Nrd)

Tension (Nrec)

Shear (Vrec)

Edge (Ncr,N)

Spacing (Scr,N)

5,14

80

8,57

6,87 9,17 12,70 7,67 11,50 20,10 10,10 15,88 29,20 14,60 22,81 54,40 19,07 36,03 84,90 21,44 45,03 122,40 26,71 62,34 194,50

Shear (Vrd)

7,20

12,00

16,80

31,20

48,80

70,40

114,00

4,91 6,55 9,07 5,48 8,22 14,36 7,22 11,34 20,86 10,43 16,30 38,86 13,62 25,73 60,64 15,31 32,16 87,43 19,08 44,53 138,93

Min Edge and Spacing

Nominal Embedment

Edge (Ccr,V)

(mm) (Cmin Smin)

(mm)

160

80

40

100

200

90

50

12,00

120

240

110

60

22,29

160

320

125

80

34,86

200

400

180

100

50,29

225

450

220

120

81,43

260

520

280

150

All data is based on correct installation - see instructions No influence of edge and spacing Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d Temperature range i maximum long term / short term temperature +24/40°C

61

60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600

Hole Hole Max diameter diameter Torque concrete fixture (mm)

(mm)

(Nm)

10

9

10

12

12

20

14

14

40

18

18

80

24

22

120

28

26

160

35

32

200

= Steel failure


chemical anchors

Vorpa CV.PE

Polyester chemical anchor

Concrete

Natural stone

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

technical data Design resistance of resin with various stud strenghts and rebar

= Steel failure

5.8 grade steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30

10 12 14 18 24 28 32 35

depth mm

hef failure

embedment depth 60 6.9 7.7

60

70 80 90 8.1 9.2 10.4 9.0 10.3 11.6 10.8 12.4 13.9 15.5 17.4 17.1 19.2

70

80

90

100 11.5 12.9 15.5 19.4 21.4 21.5

110 12.7 14.9 17.0 21.3 23.5 23.6 25.2

100

110

120 15.5 18.6 23.2 25.6 25.8 27.5 27.1 120

130 16.7 20.1 25.2 27.8 27.9 29.8 29.4 130

140 18.0 21.6 27.1 29.9 30.1 32.1 31.7 140

160 20.1 24.7 31.0 34.2 34.4 36.6 36.2 160

200 29.2 38.7 42.7 43.0 45.8 45.2 200

240

46.5 51.3 51.6 55.0 54.3 240

280

54.2 59.8 60.2 64.1 63.3 280

320

54.4 68.4 68.8 73.3 72.4 320

400

480

540

600

660

84.9 86.0 103.2 91.6 109.9 123.7 90.5 108.6 122.2 135.7 400 480 540 600 660

720

Fd,s design load

(mm)

(kN)

110 156 189 281 398 569 695 860

12.7 20.1 29.2 54.4 84.9 122.4 159.1 194.5

hef

Fd,s

720

8.8 grade steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30

10 12 14 18 24 28 32 35

depth mm

failure

embedment depth 60 6.9 7.7

60

70 80 90 8.1 9.2 10.4 9.0 10.3 11.6 10.8 12.4 13.9 15.5 17.4 17.1 19.2

70

80

90

100 11.5 12.9 15.5 19.4 21.4 21.5

110 12.7 14.2 17.0 21.3 23.5 23.6 25.2

100

110

120 13.8 15.5 18.6 23.2 25.6 25.8 27.5 27.1 120

130 15.0 16.7 20.1 25.2 27.8 27.9 29.8 29.4 130

140 16.1 18.0 21.6 27.1 29.9 30.1 32.1 31.7 140

160 18.4 20.6 24.7 31.0 34.2 34.4 36.6 36.2 160

200 19.5 25.8 30.9 38.7 42.7 43.0 45.8 45.2 200

240 37.1 46.5 51.3 51.6 55.0 54.3 240

280

54.2 59.8 60.2 64.1 63.3 280

320

61.9 68.4 68.8 73.3 72.4 320

400

480

540

600

660

85.5 86.0 103.2 91.6 109.9 123.7 90.5 108.6 122.2 135.7 400 480 540 600 660

720

design load

(mm)

(kN)

170 240 291 433 612 876 1069 1323

19.5 30.9 45.0 83.7 130.7 188.3 244.8 299.2

hef

Fd,s

720

10.9 grade steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30

10 12 14 18 24 28 32 35

depth mm

failure

embedment depth 60 6.9 7.7

60

70 80 90 8.1 9.2 10.4 9.0 10.3 11.6 10.8 12.4 13.9 15.5 17.4 17.1 19.2

70

80

90

100 11.5 12.9 15.5 19.4 21.4 21.5

110 12.7 14.2 17.0 21.3 23.5 23.6 25.2

100

110

120 13.8 15.5 18.6 23.2 25.6 25.8 27.5 27.1 120

130 15.0 16.7 20.1 25.2 27.8 27.9 29.8 29.4 130

140 16.1 18.0 21.6 27.1 29.9 30.1 32.1 31.7 140

160 18.4 20.6 24.7 31.0 34.2 34.4 36.6 36.2 160

200 25.8 30.9 38.7 42.7 43.0 45.8 45,2 200

240 37.1 46.5 51.3 51.6 55.0 54.3 240

280

54.2 59.8 60.2 64.1 63.3 280

320

61.9 68.4 68.8 73.3 72.4 320

400

480

540

600

660

85.5 86.0 103.2 91.6 109.9 123.7 90.5 108.6 122.2 135.7 400 480 540 600 660

720

design load

(mm)

(kN)

236 334 405 603 852 1220 1489 1842

27.2 43.1 62.6 116.6 182.0 262.2 341.0 416.7

hef

Fd,s

720

A4-70 grade steel studding Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 24 27 30

10 12 14 18 24 28 32 35

depth mm

failure

embedment depth 60 6.9 7.7

60

70 80 90 8.1 9.2 10.4 9.0 10.3 11.6 10.8 12.4 13.9 15.5 17.4 17.1 19.2

70

80

90

100 11.5 12.9 15.5 19.4 21.4 21.5

100

110 12.7 14.2 17.0 21.3 23.5 23.6 25.2 110

120 13.7 15.5 18.6 23.2 25.6 25.8 27.5 27.1 120

130 16.7 20.1 25.2 27.2 27.9 29.8 29.4 130

140 18.0 21.6 27.1 29.9 30.1 32.1 31.7 140

160 20.6 24.7 31.0 34.2 34.4 36.6 36.2 160

200 21.7 30.9 38.7 42.7 43.0 45.8 45.2 200

*1 = tensile strenght 500N/mm2

62

240 31.6 46.5 51.3 51.6 55.0 54.3 240

280

54.2 59.8 60.2 64.1 63.3 280

320

58.8 68.4 68.8 73.3 72.4 320

400

480

540

85.5 86.0 103.2 80.2 90.5 98.1 400 480 540

600

600

660

660

720

1 1 720

design load

(mm)

(kN)

119 169 204 304 429 615 350 434

13.7 21.7 31.6 58.8 91.7 132.1 80.2 98.1


chemical anchors

Vorpa CV.PE

Polyester chemical anchor

Concrete

Natural stone

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

technical data Design resistance of resin with various stud strenghts and rebar

Rottura acciaio

Ferri da ripresa Fyk = 500 N/mm2 Ø

Ø

Stud diameter

Hole diameter

(mm)

(mm)

8 10 12 16 20 25 28 32

10 12 15 20 25 30 35 40

depth mm

hef 60 6.1 7.3

60

70 7.1 8.5 9.1

70

80 8.1 9.7 10.4 12.7 13.6

90 9.1 10.9 11.7 14.3 15.3

100 10.1 12.1 13.0 15.9 17.0 17.8

110 11.1 13.3 14.3 17.5 18.7 19.5 20.6

120 12.2 14.6 15.6 19.1 20.4 21.3 22.5

80

90

100

110

120

130 13.2 15.8 16.9 20.7 22.1 23.1 24.4 25.5 130

140 14.2 17.0 18.2 22.3 23.8 24.9 26.2 27.4 140

160 16.2 19.4 20.8 25.5 27.1 28.4 30.0 31.4 160

200

240

24.3 25.9 31.9 33.9 35.5 37.5 39.2 200

31.1 38.2 40.7 42.6 45.0 47.1 240

Fd,s

failure

embedment depth 280

44.6 47.4 49.7 52.5 54.9 280

320

51.0 54.3 56.8 60.0 62.7 320

400

500

560

640

720

67.9 71.0 88.8 75.0 93.7 104.9 78.4 98.0 109.8 125.5 400 500 560 640 720

800

design load

(mm)

(kN)

216 281 379 549 805 1107 1429 1783

21.9 34.1 49.2 87.4 136.6 196.5 267.8 349.7

800

technical data Characteristic and Design Load resistances based on characteristic bond strengths for hef 4d (minimum embedment) to 20d - threaded mod Non Cracked Concrete Characteristic Resistance (kN) Ø mm

8

10

12

16

20

24

30

Tension (Nrk) 14,85 19,80 39,60 16,57 24,85 55,22 21,82 34,29 74,82 31,54 49,28 126,17 41,20 77,82 183,10 46,31 97,26 222,30 57,70 134,66 288,56

Shear (Vrk)

9,00

15,00

21,00

39,00

61,00

88,00

142,50

Cracked Concrete

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

6,87 9,17 18,33 7,67 11,50 25,56 10,10 15,88 34,64 14,60 22,81 58,41 19,07 36,03 84,77 21,44 45,03 102,92 26,71 62,34 133,59

Shear (Vrd)

7,20

12,00

16,80

31,20

48,80

70,40

114,00

4,91 6,55 13,10 5,48 8,22 18,26 7,22 11,34 24,74 10,43 16,30 41,72 13,62 25,73 60,55 15,31 32,16 73,51 19,08 44,53 95,42

Shear (Vrec)

Characteristic Resistance (kN) Tension (Nrk)

Shear (Vrk)

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

Shear (Vrd)

Shear (Vrec)

5,14

Not applicable

Not applicable

Not applicable

8,57

Not applicable

Not applicable

Not applicable

12,00

Not applicable

Not applicable

Not applicable

22,29

Not applicable

Not applicable

Not applicable

34,86

Not applicable

Not applicable

Not applicable

50,29

Not applicable

Not applicable

Not applicable

81,43

Not applicable

Not applicable

Not applicable

Nominal Embedment (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 480 120 280 600

All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C

63


chemical anchors

Vorpa CV.PE

Polyester chemical anchor

Concrete

Natural stone

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

technical data Characteristic and Design Load resistances for REBAR based on characteristic bond strengths for hef 4d (minimum embedment) to 20d Non Cracked Concrete Characteristic Resistance (kN) Ø mm

8

10

12

16

20

25

28

32

Tension (Nrk)

Shear (Vrk)

12,87 17,16 34,33 15,40 23,10 51,38 19,20 30,18 65,86 26,98 42,15 107,90 31,20 58,93 138,68 37,56 78,87 187,78 44,82 112,06 224,11 52,32 130,79 261,58

13.95

21,45

31,05

55,50

86,55

135,00

168,75

220,95

Cracked Concrete

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

Shear (Vrd)

6,13 8,17 16,35 7,33 11,00 24,47 9,14 14,37 31,36 12,85 20,07 51,38 14,86 28,06 66,04 17,89 37,56 89,42 21,34 53,36 106,72 24,91 62,28 124,56

9,30

14,30

20,70

37,00

57,70

90,00

112,50

147,30

4,38 5,84 11,68 5,24 7,86 17,48 6,53 10,27 22,40 9,18 14,34 36,70 10,61 20,04 47,17 12,78 26,83 63,87 15,24 38,12 76,23 17,80 44,49 88,97

Characteristic Resistance (kN)

Shear (Vrec)

Tension (Nrk)

Shear (Vrk)

Design Resistance (kN)

Recommended Load (kN)

Tension (Nrd)

Tension (Nrec)

Shear (Vrd)

Shear (Vrec)

6,64 Not applicable

Not applicable

Not applicable

Not applicable

Not applicable

Not applicable

Not applicable

Not applicable

Not applicable

Not applicable

Not applicable

Not applicable

10,21

14,79

26,43

41,21

64,29

80,36

105,22

Nominal Embedment (mm) 60 80 160 60 90 200 70 110 240 80 125 320 90 170 400 100 210 500 112 280 560 128 320 640

All data is based on correct installation - see instructions. No influence of edge and spacing. Minimum base material thickness hef +30mm >100mm for M8 to M12 and for M16 to M30 hef +2 d. Temperature range i maximum long term / short term temperature +24/40°C

Bond Strength Factors - Threaded mod Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) non cracked fc=

C15/20

C20/25

C25/30

C30/37

C35/45

C40/50

C45/55

C50/60

0.97

1.00

1.02

1.04

1.07

1.10

1.12

1.15

Influence of environmental conditions in non cracked concrete

Temp I 40°C/24°C Temp II 80°C/50°C

Dry and Wet Dry and Wet

M8

M10

M12

M16

M20

M24

M30

1.00

1.00

1.00

1.00

1.00

1.00

1.00

0.90

0.88

0.87

0.86

0.85

0.84

0.82

Bond Strength Factors - REBAR Influence of concrete strength on combined pull out and concrete cone resistance Concrete Strength N/mm2 (Mpa) non cracked fc=

C15/20

C20/25

C25/30

C30/37

C35/45

C40/50

C45/55

C50/60

0.97

1.00

1.02

1.04

1.07

1.10

1.12

1.15

Influence of environmental conditions in non cracked concrete

Temp I 40°C/24°C Temp II 80°C/50°C

Dry and Wet Dry and Wet

Ø8

Ø 10

Ø 12

Ø 16

Ø 20

Ø 25

Ø 28

Ø 32

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

0.90

0.90

0.88

0.88

0.86

0.86

0.84

0.84

64


chemical anchors

Vorpa CV.PE

Polyester chemical anchor

Concrete

Natural stone

Solid brick

Marble

Hollow brick

Perforated brick

Perforated cement

technical data Effect of anchor spacing - Tension Anchor spacing (mm) 40 50 60 70 80 90 100 120 150 160 175 200 225 240 250 275 280 300 320 350 400 425 450 480 520

Effect of edge distance - Tension

Stud/Rebar diameter 8 0,64 0,67 0,70 0,73 0,76 0,79 0,82 0,87 0,96 1,00

10 0,63 0,65 0,67 0,69 0,72 0,74 0,79 0,86 0,88 0,92 1,00

12

0,63 0,64 0,66 0,68 0,70 0,74 0,80 0,82 0,85 0,90 0,95 1,00

16

0,63 0,64 0,65 0,68 0,73 0,74 0,76 0,80 0,84 0,86 0,87 0,91 0,92 0,95 1,00

20

0,63 0,65 0,68 0,70 0,71 0,74 0,77 0,79 0,80 0,83 0,84 0,86 0,88 0,92 1,00

24

0,63 0,65 0,66 0,68 0,71 0,74 0,76 0,77 0,80 0,80 0,82 0,85 0,88 0,94 0,97 1,00

30

0,63 0,64 0,65 0,68 0,70 0,72 0,73 0,75 0,76 0,78 0,80 0,83 0,88 0,90 0,93 0,96 1,00

Edge distance (mm) 40 50 60 70 80 90 100 110 120 140 160 180 200 225 250 260

Effect of edge distance - Shear

Stud/Rebar diameter 8 0,64 0,73 0,82 0,90 1,00

10 0,63 0,70 0,77 0,84 0,91 1,00

12

0,63 0,68 0,74 0,80 0,86 0,92 1,00

65

16

0,63 0,67 0,71 0,76 0,80 0,89 1,00

20

0,63 0,66 0,70 0,77 0,84 0,91 1,00

24

0,64 0,68 0,76 0,84 0,92 1,00

30

0,63 0,66 0,72 0,78 0,86 0,94 1,00

Edge distance (mm) 40 50 60 70 80 90 100 110 125 140 160 180 200 225 250 280

Stud/Rebar diameter 8 0,25 0,44 0,63 0,81 1,00

10 0,30 0,48 0,65 0,83 1,00

12

0,30 0,44 0,58 0,72 0,86 1,00

16

20

24

0,40 0,53 0,67 0,35 0,80 0,44 1,00 0,58 0,35 0,72 0,45 0,91 0,58 1,00 0,71 0,84 1,00

30

0,30 0,36 0,47 0,59 0,74 0,88 1,00


chemical anchors

Vorpa CV MULTISET PLUS Polyester styrene free pourable resin

Concrete

Natural stone

Solid brick

Marble

products group Suitable • concrete • natural stone • solid brick • marble

CV MULTISET PLUS 5 kg. container unit

CV MULTISET PLUS 1 kg. container unit

To fix • anchoring threaded steel bolts into solid surfaces, typically cementitious surfaces • bedding-in coping stones, concrete units, steel, concrete or wooden posts. • repairs to large cracks in concrete surfaces requiring a self-levelling characteristic or difficult to reach areas. • traffic signs • crash-noise barriers on the road • bus shelters

product information Characteristics • Multiset Plus is a two component polyester mortar to fix threaded rod or rebar in a concrete floor, stone or plain brick. As a liquid product it can also be used to fill cracks. Ideal to fix playground equipment and bus shelters, traffic signs, crash and noise barriers on the road. Benefits • Fixing of rods or rebars in solid and hollow supports • Useful to fill cavities, cracks or difficult access areas • High solid content • Easy to apply • Slight contraction • High mechanical and physical resistance

Suggestion for use • Remove water and dirt (dust and loose material) with a circular brush and a blower or with air pressure. • Prepare the mixture of Multiset Plus with base and hardener. • Mix both components thoroughly to reach a homogeneous mixture (if necessary, use a drill with a mixer). • The items to be fastened must be clean. • Spill the product from the base of the hole until 2/3 full. • Insert the element to be fastened rotating, if necessary, keep the position with a suitable device. • Wait the recommended working and drying times. Before injection, verify the expiry date of the product, the support resistance and the ambient temperature. Setting and any subsequent adjustment are only possible during working time. In unopened original packaging, one year from manufacturing date. Store the product in a ventilated place away from direct exposure to sunlight. Keep between 5ºC and 25ºC.

66


chemical anchors

Vorpa CV MULTISET PLUS Polyester styrene free pourable resin

Concrete

Natural stone

Solid brick

Marble

B

installation sequence

A

A

B

A

A

technical data Code

Description

1175 1174

content kg

content box

5 1

base + hardener base + hardener

CV. MULTISET PLUS KG CV. MULTISET PLUS KG

Physical properties • Nature: unsaturated polyester resin • Colour: grey • Specific weight: 1,65 kg/l at 20ºC • VOC: 6,0 g/l Mixing Application

Working and hardening times Base material temperature (C°) Working time (min) Loading time (min)

5 55 240

20 18 120

10 40 180

25 12 90

30 8 60

35 6 50

Performance data for rods into concrete Anchor Rod Class 5.8

Installation

Resistance

Admissible loads

Drill diameter d0

Embedment depth hef

Standard edge distance Ccr

Standard anchor distance Scr

Torque moment Tinst

Characteristics resistance NRk

Concrete C20/25

Concrete C20/25

[mm]

[mm]

[mm]

[mm]

[N.m]

Tensile [kN]

Tensile [kN]

Shear [kN]

14 18 24 28

110 140 180 220

110 140 180 440

220 280 360 220

40 60 100 150

22,7 38,5 61,9 90,7

7,6 12,8 20,6 30,2

13,4 24,9 39,2 52,3

M12 M16 M20 M24

Safety factor for tension load 3,0

Performance data for rebar into concrete Bar diameter ds

Drill diameter d0

[mm]

[mm]

12

16

14

18

16

20

20

25

25

32

Ultimate load Fs in C20/25 concrete High adherence 500 MPa steel rebar Embedment depth Tension load

10 ds [mm] [kN]

20 ds [mm] [kN]

30 ds [mm] [kN]

40 ds [mm] [kN]

50 ds [mm] [kN]

Lv Fs [C20/25] Lv Fs [C20/25] Lv Fs [C20/25] Lv Fs [C20/25] Lv Fs [C20/25]

120 7,6 140 10,0 160 12,7 200 19,9 250 31,8

240 15,3 280 20,0 320 25,4 400 39,7 500 63,6

360 22,9 420 30,0 480 38,1 600 59,6 750 95,4

480 30,6 560 40,1 640 50,9 800 79,5 1000 127,2

600 38,2 700 50,2 659 63,7 1000 99,6 1250 159,0

Mechanical characteristics CV MULTISET PLUS Tensile strength Tensile modulus Compressive strength Compressive strength Flexural strength Flexural modulus

Units

Standard

Average value

[N/mm2] [N/mm2] [N/mm2] [N/mm2] [N/mm2] [N/mm2]

ASTM D638 ASTM D638 ASTM D695 EN 196-1 ASTM D790 ASTM D790

11,6 5045 76 76 21 1402

67


chemical anchors

Vorpa Bitumphalte 130 Bituminous adhesive bond

Road floors Asphalt

Metals

Cement

product group Suitable • road floors • asphalt • cement • metals

To fix • road marker, “cat’s eyes” • lane dividers, plastic cones • rubber on pavement

BITUMPHALTE 130 4,5 Kg steel can Examples of application

product information Characteristics • bituminous adhesive bond for the application of rubber and semi-rigid PVC to concrete, asphalt and metal Chemical composition • Bitumen, special solvent for quick drying, inert fillers selected resins, fibers, plasticizers, additives Suggestion • Any adjustment of the product is possible only before the drying

Use • It is important surfaces to be treated being completely dry, clean and free from oil and dust flour or other. It’s ready to be used and should be applied with a spatula. Drying times vary depending on the type of support, the layer thickness realized and the ambient temperature. Given to the high thixotropy, the application of the product is easy both horizontally and vertically. Tools, clothing and dirty hands can be cleaned with common synthetic thinners or nitro

installation sequence

technical data Code

1177

Description

BITUMPHALTE 130

Product Features content kg

content box

4,5

bituminous adhesive bond

Shelf life 24 months in original closed cup

BITUMPHALTE 130

Colour Characteristic Specific weight 20°C Dry residue at 130°C Viscosity brookfield (GIR. n°7 - 10 rpm)

68

standard

average value

EN ISO 2811-1 EN ISO 3251

black tixotropic resin 1,10 kg/l/-0,003 73%-81%

25°C

850P/-150


chemical anchors

Vorpa ROOF AND GUTTER SEALANT

Bitumen based mastic providing an effective seal between all roofing materials products group Limitations • do not use on glass • do not use on PVC • do not use internally

Areas for use • fills and seals gaps/cracks in most roofing applications • bonds to: concrete, roofing felt, lead, zinc, steel and masonry • for bedding tiles, slates and flashing into position • joint sealing on gutters and down pipes • sticking down loose roofing felt • joint sealing between corrugated asbestos cement and iron sheeting etc.

product information Benefits • Incorporates polymer additives to improve adhesion • Can be applied in wet conditions, even under heavy rain • Semi drying - remains permanently elastic beneath surface skin • High solids formulation - excellent gap filling properties without shrinkage • Excellent external weathering properties • Form ready to use thixotropic paste, black in colour • Elastoplastic sealant adhesive based on bituminous elastomeric resins which adhere on most common building materials, even on wet surfaces, forming a flexible film • For bonding and sealing of roofs, insulation materials (excluded expanded PS), ceramic tiles, roofing tiles, polymeric surfaces (plastics) free of plasticizers. To seal and waterproof joints, cracks, various breakings, car body shells, etc. Adheres on concrete, zinc, wood, aluminium, metal sheet, etc. Good occasional resistance to solvents, except turpentine and mineral oils. Not overpaintable, not compatible with other sealants

Benefits • Color black • Specific weight ca. 1,02 g/cm3 • Viscosity fixotropic paste • Boiling point 150 °C • Flash point > 39 °C • Application temperature 5 ÷ 30 °C • Open time < 20 min. • Temperature resistance -35 ÷ 110 °C • Strain absent Surface preparation • Surfaces must be sound, clean and dry, free of oil and other contaminants. Apply with sealant gun in curbs. Complete curing depends on width and atmospheric conditions and may take from 12 hours to 2 days. Anyway, after some hours a good adhesion and consistence are obtained. Tools can be cleaned with mineral turpentine. Consumption as adhesive: ca. 310 ml/mq Consumption as sealant (0,5 x 0,5) cm: ca. 10 meters

application

Code

2300

Description

VORPA BITUM

Content ml

Gun to be used

310

silicone

69


chemical anchors

Vorpa Battery tool 14.4V Extrusion tools for chemical anchors products information Battery tool 14.4 V for chemical anchors co-axial up to 410ml

Weight • Cordless caulking gun: 2.40 Kg • Case including caulking gun and charger: 5.8 Kg

Main features • Trigger with speed control. Maximum extrusion rate 0-4,5 mm/s. • Extrusion power 550 Kgf. • Anti-dripping. Applications • Suitable for 410ml 10:1 co-axial cartridges. • Continuous and clean work. • Easy to carry thank to the apposite case containing extra battery pack and battery charger. • Li-ion battery with low self-discharge rate, no memory effect, long life, light weight. • LED auxiliary light. • Voltage characteristics: 14.4V 1.5AH 220V/230V.

Vorpa EASY PRESS 14,4V 380/410 COAX Cordless sealing gun Easy Press 14,4 V Li-Ion for chemical anchors co-axial cartridges up to 410 ml

Vorpa EASY PRESS 14,4V SPARE PARTS 14,4V extra battery Li-Ion pack

Code

9109

Code

9110

Performances • Each charge of battery can plunge up to 45 tubes of 410ml chemical anchor cartridge. • Durable battery life for 500 charge-discharge cycles. Kit Case Content • n°1 Easy Press 14.4V • n°2 Li-ion Battery Packs 14.4V • 14.4V Battery Charger • Blow mould plastic case

Description

Description

• Suitable for: CV.VSF 400 CE - CV.PSF 410 - CV.PE 410 CV.ESF 410 • Kit case content: n° 1 Easy Press 14,4V 410 Coax n° 2 Battery packs n° 1 Battery charger

Easy Press 14.4V 380/410 ml coax 550 Kgf thrust 10:1 co-axial cartridges weight kg 2,4

Description

Li-Ion extra charger

Vorpa EASY PRESS 14,4V SPARE PARTS 14,4V Li-Ion extra charger

70

Code

9111

Description

14,4 charger


chemical anchors

Vorpa CVB - CVD

steel internal threaded sleeves for concrete masonry and hollow bricks technical data

CVD steel internal threaded sleeve

CVB steel internal and external threaded sleeve

technical data Steel sleeve CVD Code

1236 1237 1238

Steel sleeve CVB Description

d0 mm

Lt mm

Lf mm

h1 mm

hef mm

db mm

CV D 12x80 CV D 14x80 CV D 16x80

14 16 18

80 80 80

55 55 55

90 90 90

80 M8 80 M10 80 M12

Code

1036 1037 1038 1039

Description

d0 mm

Lt mm

Lf mm

h1 mm

hef mm

db mm

M mm

CV B 12x80 CV B 12x80 CV B 16x80 CV B 16x80

14 14 18 18

80 80 80 80

32 32 32 32

90 90 90 90

80 M6 M14 80 M8 M14 80 M10 M16 80 M12 M16

Usable for application on hollow brick with plastic sleeves and solid brick. Lf

LTffix

Tfix

Lf

M db

d0

db

Øb

d0

Lt h1

db

d0

db

Øb

Lt

Lt h1

hef

= Anchor length = Stud length = Hole diameter = Internal sleeve thread = Min. hole depth

installation sequence hollow brick

solid brick

Performance based on clean holes.

71

Stud length calculation: Lb = Lt +Tfix Lt = Anchor length Tfix = Fixture thickness

Lt h1

hef

hef = Effective anchorage depth Øb = Stud diameter Tfix = Fixture thickness Lf = Internal thread length M = External sleave thread

Tfix

M

d0

h1 hef

Lt Lb d0 db h1

Øb

LTffix

hef

Øb


chemical anchors

Vorpa asphalt anchor system CV F Steel threaded sleeve for anchor stud on asphalt surfaces

Asphalt

Product group Characteristics Asphalt anchor system to be used with chemical anchors Easy and safe solution on asphalt and various base material surfaces Benefits High performances. Fixture can be removed and replaced. No expansion stress in the base material. Versatile and flexible To fix Road signs, parking protection, bollards, fencing, shelters Edge protections, playgrounds, speed bumps

Examples of applications

Installation sequence

Technical data Code

Description

52190 52191 52192 52193

CVF 12x70 CVF 12x100 CVF 14x70 CVF 14x100

Pull out failure

Anchor length 70 mm Anchor length 100 mm

Fi mm

d0 mm

Lt mm

h1 mm

M 10x20 M 10x20 M 12x20 M 12x25

14 14 16 16

70 100 70 100

75 105 75 105

h1 Lt d0 Lt d0 Fi h1

Tension

10 kN 18 kN * 1kN ≃ 100 Kg

72

= Anchor length = Hole diameter = Internal thread = Minimum hole length


chemical anchors

Vorpa CLOU PERFORATED SLEEVE Safe fixing on hollow materials to be used with chemical anchor

Hollow brick

Perforated brick

Perforated cement

products group Examples of application

technical data

Code

2903

Description

d0 mm

db mm

Lt mm

h1 mm

CLOU 10x145

10

8

145

150

technical data Permissable loads in daN Clou Hollow brick Perforated brick Perforated cement

daN daN daN

315 415 500

8 x 12 holes

installation sequence

Lt = Hole diameter d0 = Anchor length

8 x 10 holes

db = Sleeve internal diameter h1 = Min. hole depth

SOCOTEC Specification report EAD 6802/1

73


chemical anchors

Vorpa CVA

plastic perforated sleeve for hollow bricks technical data

Usable for application on hollow brick with M8-M14 studs

technical data

Code

914 1914

Description

d0 mm

Lt mm

h1 mm

hef mm

Ă˜b mm

CV A 13x100 CV A 15x100

14 16

100 100

110 110

100 100

M8-M12 M8-M14

hef

Tfix

h1

db

db

d0

Lt Lb

Lt = Anchor length Lb = Stud length d0 = Hole diameter db = Internal sleeve thread h1 = Min. hole depth hef = Effective anchorage depth Ă˜b = Stud diameter Tfix = Fixture thickness Stud length calculation: Lb = Lt +Tfix Lt = Anchor length Tfix = Fixture thickness

installation sequence

74


chemical anchors

Vorpa CVH

steel perforated sleeve for hollow bricks with bent end technical data

CVH

technical data

Code

2912 2913 2914

Description

CV H 15 x 85 CV H 15 x 130 CV H 17 x 130

d0 mm

h1 mm

15 15 17

90 140 130

do mm

Lt mm

Øb mm

85 130 130

M8-M10 M8-M10 M10-M14

Tfix

h1

db

Øb

d0

Lt Lb

Lt = Anchor length Lb = Stud length d0 = Hole diameter db = Internal sleeve thread h1 = Min. hole depth hef = Effective anchorage depth Øb = Stud diameter Tfix = Fixture thickness Stud length calculation: Lb = Lt +Tfix Lt = Anchor length Tfix = Fixture thickness

installation sequence

Performance based on clean holes.

75


chemical anchors

Vorpa CV K

steel perforated sleeve for hollow bricks adustable in depth with sheet metal shears technical data

CV K

technical data

Code

2900 2901 2902

Description

d0 mm

db mm

Lt mm

Øb mm

CV K 12/1000 CV K 16/1000 CV K 22/1000

12 16 22

9,5 12,5 18,5

1000 1000 1000

M8 M10-M12 M12-M16

Tfix

h1

db

Øb

d0

Lt Lb

Lt = Anchor length Lb = Stud length d0 = Hole diameter db = Internal sleeve thread h1 = Min. hole depth hef = Effective anchorage depth Øb = Stud diameter Tfix = Fixture thickness Stud length calculation: Lb = Lt +Tfix Lt = Anchor length Tfix = Fixture thickness

installation sequence

Performance based on clean holes. 76


chemical anchors

Vorpa CV X

plastic perforated sleeve for hollow bricks technical data plastic perforated sleeve for hollow bricks

technical data

Code

1006 1006E 51006 913 1017 915

Description

CV X 12 X 50 CV X 12 X 60 CV X 12 X 80 CV X 16 X 85 CV X 16 X 130 CV X 20 X 85

d0 mm

Lt mm

h1 mm

hef mm

Øb mm

12 12 12 16 16 20

50 60 80 80 130 85

60 70 90 90 140 95

50 60 80 80 130 85

fino a 8 fino a 8 fino a 8 8 - 12 8 - 12 12 - 16

hef

Tfix

h1

db

Øb

d0

Lt Lb

Lt = Anchor length Lb = Stud length d0 = Hole diameter db = Internal sleeve thread h1 = Min. hole depth hef = Effective anchorage depth Øb = Stud diameter Tfix = Fixture thickness Stud length calculation: Lb = Lt +Tfix Lt = Anchor length Tfix = Fixture thickness

installation sequence hollow brick

Performance based on clean holes. 77


chemical anchors

Vorpa CVX

plastic perforated sleeve for hollow bricks adustable in depth technical data

CVX

technical data

Code

Description

d0 mm

h1 mm

h2 mm

hef mm

Lt mm

Øb mm

Tfix min mm

Tfix max mm

51017

CVX 16x330

18

135

340

130

330

M10-M12

20

200

h2 h1 Tfix

d0

Øb

hef Lt

Lt = Anchor length d0 = Hole diameter h1 = Min. hole depth h2 = Max hole depth hef = Effective anchorage depth Øb = Stud diameter Tfix = Fixture thickness

installation sequence

Tinst=4Nm

Tfix

Performance based on clean holes. 78


chemical anchors

Vorpa ACCESSORIES Fixing accessories products group • Ideal for various applications • the bars can be cut to size • Available also with nut and washer

• Suitable on compact materials with CVB-CVD metal sleeves • Suitable on hollow materials with CVX-CVA-CVH plastic sleeves

• Suitable for each applications with chemical anchors and mechanical anchors

Installation sequence Example of applications for threaded bars with chemical anchors and plastic/metal sleeves

Application on compact material for CVB metal sleeve

Application on compact material for CVD metal sleeve

Application on hollow material for CVX plastic sleeve

Application on hollow material for CVK metal sleeve

Application on hollow material for CVA plastic sleeve

Example of applications for threaded bars with chemical resin capsules

Installation sequence on compact base material VF CE resin capsule

Installation sequence on compact base material VFP resin capsule

technical data

5.8

S VFA INOX A4 A4 stainless steel anchor stud VFA hexagonal head with nut and washer. Code

Description

51920 51921 51922 51924 51926 51928

VFA A4 M8 x 110 VFA A4 M10 x 130 VFA A4 M12 x 160 VFA A4 M16 x 190 VFA A4 M20 x 260 VFA A4 M24 x 300

* *

hexagons thread S

thread

stud length

hole Ø

5 7 8 12 14 14

M8 M10 M12 M16 M20 M24

110 130 160 190 260 300

10 12 14 18 24 28

VFM 5.8 steel anchor stud VFM hexagonal head with nut and washer. Code

2920 2921 2922 2924 2925 2926 2956

One driver tool in each box

Condition of ETA validity: use the threaded bars together with VORPA VF CE Resin capsules

Description

VFM M8 x 110 VFM M10 x 130 VFM M12 x 160 VFM M16 x 190 VFM M20 x 260 VFM M24 x 300 VFM M30 x 380

* * 79

hexagons thread S

thread

stud length

hole Ø

80 90 110 125 170 210 275

M8 M10 M12 M16 M20 M24 M30

110 130 160 190 260 300 380

10 12 14 18 22 26 32

One driver tool in each box

Condition of ETA validity: use the threaded bars together with VORPA VF CE Resin capsules


chemical anchors

Vorpa ACCESSORIES Fixing accessories technical data

8.8 VFG steel anchor stud VFG with nut and washer Code

922 924 926 928 956

VFG 8.8 8.8 steel anchor stud VHA with nut and washer

Description

thread

stud length

hole Ø

VFG M12 x 160 VFG M16 x 190 VFG M20 x 260 VFG M24 x 300 VFG M30 x 380

M12 M16 M20 M24 M30

160 190 260 300 380

14 18 24 28 40

Code

9922 9924 9926 9928 9956

Description

thread

stud length

hole Ø

VFG 8.8 M12 x 160 VFG 8.8 M16 x 190 VFG 8.8 M20 x 260 VFG 8.8 M24 x 300 VFG 8.8 M30 x 380

M12 M16 M20 M24 M30

160 190 260 300 380

14 18 24 28 40

*

ZINCATO CALDO

One driver tool in each box

HOT DIP COATING

*

VFG ZC hot dipped galvanized steel anchor stud VFG with nut and washer Code

Description

thread

stud length

hole Ø

58025 58026 58027 58028 58029 58030

VFG ZC M10 x 130 VFG ZC M12 x 160 VFG ZC M16 x 190 VFG ZC M20 x 260 VFG ZC M24 x 300 VFG ZC M30 x 360

M10 M12 M16 M20 M24 M30

130 160 190 260 300 360

12 14 18 24 28 40

CVM steel anchor stud CVM with nut and washer Code

911 916 912 917 918 919

Condition of ETA validity: use the threaded bars together with VORPA VF CE Resin capsules

S

DRIVER TOOL

Description

thread

stud length

hole Ø

CVM 8 x 75 CVM 8 x 100 CVM 10 x 95 CVM 10 x 110 CVM 10 x 140 CVM 12 x 115

M8 M8 M10 M10 M10 M12

75 100 95 110 140 115

10 10 12 12 12 14

Code

945 946 947A 949 951 953 954 955

80

Description

Internal thread S min

Ø tang mm

VFG M 8 VFG M 10 VFG M 12 VFG M 16 VFG M 20 VFG M 24 VFG M 27 VFG M 30

M8 M10 M12 M16 M20 M24 M27 M30

8 10 10 13 13 13 13 13


chemical anchors

Vorpa ACCESSORIES Fixing accessories technical data

4.8 DIN 975

4.8 threaded bar cm 100 Code

1020 1021 1022 1023 1026 1024 1027 1025 1034 1035 1052 1053

Description

M 6x1000 M 8x1000 M 10x1000 M 12x1000 M 14x1000 M 16x1000 M 18x1000 M 20x1000 M 22x1000 M 24x1000 M 27x1000 M 30x1000

8.8

thread

M 6 M 8 M 10 M 12 M 14 M 16 M 18 M 20 M 22 M 24 M 27 M 30

stud length

hole Ø

100 100 100 100 100 100 100 100 100 100 100 100

8 10 12 14 16 18 22 24 26 28 32 40

8.8 threaded bar cm 100 Code

Description

90462 90463 90464 90490 90485 90484 90488 90489

M 8x1000 M 10x1000 M 12x1000 M 14x1000 M 16x1000 M 20x1000 M 24x1000 M 27x1000

DIN 975 thread

M 8 M 10 M 12 M 14 M 16 M 20 M 24 M 27

stud length

hole Ø

100 100 100 100 100 100 100 100

10 12 14 16 18 24 28 32

4.8 4.8 threaded bar cm 300 Code

Description

50167 50173 50174 50175 50055

M 6x3000 M 8x3000 M 10x3000 M 12x3000 M 16x3000

A2 stainless steel threaded bar cm 100

DIN 975 thread

M 6 M 8 M 10 M 12 M 16

stud length

hole Ø

300 300 300 300 300

8 10 12 14 18

Code

4060 4061 4062 4063 4065

Description

M 6x1000 M 8x1000 M 10x1000 M 12x1000 M 16x1000

A4 stainless steel on request

81

thread

M 6 M 8 M 10 M 12 M 16

DIN 975 stud length

hole Ø

100 100 100 100 100

8 10 12 14 18


chemical anchors

Vorpa VF CE RESIN CAPSULES

Vinylester resin capsule with ETA option 7 for non-cracked concrete “spin-in” type

Non-cracked Concrete

products group

VF CE RESIN CAPSULE

Suitable • non-cracked concrete

To fix • starter bar applications • threaded studs • crush barriers • machinery - cladding • steel columns • guardrails • noise protection walls • balustrades

European Technical Approval Option 7 for non-cracked concrete

Software Vorpa Calcul Anchor

product information Characteristics • Chemical anchors VF CE consist of a capsule containing a blend of resin, quarts, sand and special hardener encapsulated in a small glass capsule. The capsule is placed into a drilled hole previously cleaned and threaded rod is driven by machine with turning (simultaneous hammering and turning).

Suggestions for use • Avoid direct sunlight. • Clean out hole thoroughly before application. • Anchors to be tightened with calibrated torque wrench. • See ETA for more details

Benefits • Capsules can be set in either direction. • Quick curing and gel time. • No waste of material. Safe and easy to use. • Chemical corrosion resistant. • Can be installed in wet concrete or in hole filled with water. • Product with ETA option 7 for non-cracked concrete. • Suitable for close edge applications, no tension on base material.

technical data Art.

5900 5901 5902 5904 5906 5908

Description

VF CE M 8 VF CE M 10 VF CE M 12 VF CE M 16 VF CE M 20 VF CE M 24

Length mm

Storage Shelf life

80 80 95 95 160 190

Store in cool and dry place between +5°C and + 25°C. Shelf life 24 months from the manufacture date.

82


chemical anchors

Vorpa VF CE RESIN CAPSULES

Vinylester resin capsule with ETA option 7 for non-cracked concrete “spin-in” type

Non-cracked Concrete

installation sequence Standard cleaning

X2

X2 Premium cleaning

X2 >6 BAR X2

X2 technical data Minimum curing time and working time Concrete temperature (C°)

Minimum curing time (dry concrete)

Minimum curing time (wet concrete)

-5° - 0 0-5 5 - 10 10 - 20 > 20

360 180 90 40 20

720 360 180 80 40

Specification data

Hole diameter Hole diameter in fixture Minimum hole depth Minimum slab thickness Torque moment Minimum spacing Minimum edge distance

dO dfix hO hmin Tinst Smin Cmin

mm mm mm mm Nm mm mm

M8

M10

M12

M16

M20

M24

10 9 80 110 10 60 60

12 12 90 120 20 70 70

14 14 110 150 40 85 85

18 18 125 160 60 95 95

25 22 170 220 120 130 130

28 26 210 300 150 160 160

83


chemical anchors

Vorpa VF CE RESIN CAPSULES

Vinylester resin capsule with ETA option 7 for non-cracked concrete “spin-in” type

Non-cracked Concrete

technical data Performance data Threaded size Embedment depth Tension load Standard cleaning Characteristic resistance non cracked concrete C20/25 - (50/80°C) Design resistance ɤMC=1.8 Premium cleaning Characteristic resistance non cracked concrete C20/25 - (50/80°C) Design resistance ɤMC=1.8 Increasing factors C30/37 C40/50 C50/60 Shear load Steel Failure, Steel Grade 5.8 Characteristic resistance Design resistance ɤMs=1.3 Steel Failure, A4 - 70 Steel Grade Characteristic resistance Design resistance ɤMs=1.56 Bending Moment Steel Failure, Steel Grade 8.8 Characteristic resistance Design resistance ɤMs=1.3 Steel Failure, A4 - 70 Steel Grade Characteristic resistance Design resistance ɤMs=1.56

M8 M10 M12 M16 M20 M24 0.55 0.58 0.63 0.69 0.76 0.82 0.89 0.96 1.00

0.54 0.59 0.64 0.69 0.74 0.80 0.85 0.94 1.00

0.54 0.58 0.62 0.66 0.70 0.74 0.81 0.88 0.95 1.00

0.53 0.56 0.59 0.62 0.65 0.70 0.75 0.80 0.89 0.99 1.00

M10

M12

M16

M20

M24

hef

mm

80

90

110

125

170

210

NRk,P

kN

9

12

16

25

40

60

NRd,s

kN

5

6,6

8,8

13,8

22,2

33,3

NRk,P

kN

12

16

25

35

60

75

NRd,s

kN

6,6

8,8

13,8

19,4

33,3

41,6

ψc ψc ψc

1,08 1,15 1,19

VRk,c VRd,c

kN kN

8 6,2

13 10

19 14,6

36 27,6

57 43,8

83 63,8

VRk,c VRd,c

kN kN

11 7

17 10,8

26 16,6

49 31,4

77 49,3

111 71,2

MRk,s MRa,s

kN kN

16 12,3

30 23

56 43

144 110

285 219

498 383

MRk,s VRd,s

kN kN

22 14

41 26,2

75 48

194 124,3

384 246

670 429,4

Edge distance (shear)

Edge distance (tension load)

CN mm 40 45 55 65 75 85 95 105 120 135 150 175 200 225 250 275 300 335

M8

0.54 0.57 0.59 0.63 0.67 0.71 0.79 0.86 0.94 1.00

0.56 0.59 0.63 0.66 0.72 0.79 0.85 0.92 0.99 1.00

CV mm 40 50 60 70 80 90 100 120 140 160 180 200 220 260 320 360 405 450 490

M8 M10 M12 M16 M20 M24 0.36 0.45 0.54 0.63 0.72 0.81 0.90 1.08 1.26 1.44

0.38 0.46 0.54 0.62 0.69 0.77 0.92 1.08 1.23 1.38 1.54

0.37 0.44 0.50 0.56 0.62 0.75 0.87 1.00 1.12 1.25 1.37 1.62

84

0.35 0.40 0.44 0.49 0.59 0.69 0.79 0.89 0.99 1.09 1.28 1.58

0.37 0.41 0.49 0.57 0.66 0.74 0.82 0.90 1.07 1.31 1.48

0.43 0.50 0.58 0.65 0.72 0.79 0.94 1.15 1.30 1.46

Spacing

S mm 40 50 60 70 80 90 100 120 140 160 180 200 220 260 320 360 405 450 490 550 600 670

M8 M10 M12 M16 M20 M24 0.59 0.61 0.64 0.66 0.68 0.70 0.73 0.77 0.82 0.86 0.91 0.95 1.00

0.60 0.62 0.63 0.65 0.67 0.69 0.73 0.77 0.81 0.85 0.88 0.92 1.00

0.59 0.61 0.62 0.64 0.66 0.69 0.72 0.75 0.78 0.81 0.84 0.90 1.00

0.59 0.60 0.61 0.62 0.65 0.67 0.70 0.72 0.75 0.77 0.82 0.90 0.94 1.00

0.59 0.60 0.62 0.64 0.66 0.68 0.70 0.73 0.77 0.83 0.87 0.91 0.96 1.00

0.61 0.63 0.64 0.66 0.68 0.70 0.73 0.79 0.82 0.86 0.91 0.94 1.00


chemical anchors

Vorpa FOAMPLUS UNIVERSAL Self-expanding polyurethane foam products group To fix • Windows and doors frames • Pipes insulation • Fixing of Insulating panels • Do it yourself works • Electrical installations • Fillings and finishing touches

FOAMPLUS UNIVERSAL SPRAY TYPE

FOAMPLUS UNIVERSAL GUN TYPE product information Characteristics • Self-expanding one component polyurethane foam available in Spray and Gun types. • It expands and hardens with air humidity. Benefits • High adhesion to most of the building materials. • High filling capacity, up to 45lt. • After setting it can be treated mechanically. • Chemical agents, moulds and micro-organisms resistant. • CFC free propellent. Non harmful for users and ozone layer. • Waterproof. • Sound-proofing and heat insulation properties.

Instructions for use • Shake before using. • The surface of application must be well cleaned. Remove dust, oil and grease. • Surfaces must be moistened with water. • Apply upward. In presence of wide hollow materials it is suggested to repeat the application after setting. • The application can be interrupted in any moment, leave the bottle turned on the gun till completely empty. • Avoid any contact with sources of ignition, heat, flames.

application FOAMPLUS spray type

FOAMPLUS gun type

Stability load bearing (Ø12 mm joint)

technical data Code

3780 3781

Description

FOAMPLUS UNIVERSAL SPRAY TYPE FOAMPLUS UNIVERSAL GUN TYPE

Content ml

Extrusion

750 750

Spray For gun

Colour beige Content ml. 750 State liquefied gas in pressure content Specific weight (extruded) 25-30 kg/m3 Foam yeld / 1000 ml ca. 30 liters Skin formation time (23°C, 50% H.R.) 12-16 min. Can be cut (23°C, 50% H.R.) 30-40 min. Tensile strength (BS 5241) 11 N/cm2 Pressure strength (DIN 53421) 2 N/cm2

Thermal conductivity Temperature resistance Application temperature Flammable Class Storage

85

30 mW/m°K -50°C ÷ +90°C +5°C ÷ +30°C B3 (DIN 4102, 1st part) Cool and dry place. Vertical position, temperature below 30°C 12 months in original, unopened packing at cool and dry place


chemical anchors

Vorpa FOAMPLUS FOR ROOFING Self-expanding polyurethane foam products group To fix • Pipes insulation • Roofing tiles fixings • Fillings and finishing touches • Fixing of Insulating panels • Windows and doors frames • Chimney flues insulation

FOAMPLUS FOR ROOFING SPRAY TYPE

FOAMPLUS FOR ROOFING GUN TYPE product information Characteristics • Self-expanding one component polyurethane foam available in Spray and Gun types. • It expands and hardens with air humidity. Benefits • Suitable for repairing of roofing. • High adhesion to most of the building materials. • High filling capacity, up to 45lt. • After setting it can be treated mechanically. • Chemical agents, moulds and micro-organisms resistant. • CFC free propellent. Non harmful for users and ozone layer. • Polymerize at low temperatures.

Instructions for use • Shake before using. • The surface of application must be well cleaned. Remove dust, oil and grease. • Surfaces must be moistened with water. • Apply upward. In presence of wide hollow materials it is suggested to repeat the application after setting. • The application can be interrupted in any moment, leave the bottle turned on the gun till completely empty. • Avoid any contact with sources of ignition, heat, flames.

application FOAMPLUS spray type

FOAMPLUS gun type

Stability load bearing (Ø12 mm joint)

technical data Code

3788 3789

Description

FOAMPLUS FOR ROOFING SPRAY TYPE FOAMPLUS FOR ROOFING GUN TYPE

Content ml

Extrusion

750 750

Spray For gun

Colour grey Content ml. 750 State liquefied gas in pressure content Specific weight (extruded) 25-30 kg/m3 Foam yeld (extruded) > 40 % Skin formation time (23°C, 50% H.R.) 12-16 min. Can be cut (23°C, 50% H.R.) 30-40 min. Tensile strength (DIN 53455) > 100 KPa Pressure strength (DIN 53421) > 25 KPa Volume variation < 2 % Vol.

Thermal conductivity (DIN 52612) Acoustic Insulation (EN ISO 717-1) Temperature resistance Application temperature Flammable Class Storage

86

0,034 W/(m°K) 60 dB -40°C ÷ +90°C -10°C ÷ +35°C B3 (DIN 4102, 1st part) Cool and dry place. Vertical position, temperature below 30°C 12 months in original, unopened packing at cool and dry place


chemical anchors

Vorpa FOAMFAST 750

Self-expanding special adhesive for rapid installation of exterior insulation finishing EPS panels. products group

THERMIC

INSULATYION

5-6m2

For gun

SELF-EXTINGUISHING

2h

ENERGY SAVING

Output in square

product information Characteristics • Gun adhesive sticks to all common construction materials for filling and fixing gaps in exterior insulation finishing Benefits • The high output and powerful initial bond strength enable rapid, efficient panel mounting • The product is ready to use and requires no additional support structures • EIFS gun adhesive is used in place of mortar mixes • Particulary suitable for bonding insulating panels, adheres on most of the building materials (PS, PU, bituminous). Does not adhere on PP, PE, TEFLON and silicons. • Protect from direct sunlight exposure. Overpaintable • Installation yield: 5-6 sqm. • It is not subject to ageing, but is susceptible to UV radiation damage. Excellent thermal and sound insulation properties • Simple time-saving application • Powerful initial bonding • Low storage space requirement • Clean application • Construction material B2 according to DIN 4102

application

87

Instructions for use • Shake well before use. Apply fist on the edges of panels, then zig-zag spray on clean, dust- and greasefree surfaces using the specific gun, keeping the can upside down. (moistening surfaces improves adhesion, curing and structure). • Wait about 2 minutes before install and align panels within 5 minutes. • Delete possible big surfaces irregularity by applying mortar before placing panels. • In case of rain or wind, protect panels as it takes 2 hours for the adhesive to reach the appropriate mechanical properties. • In case of further applications (over 24 hours after) immediately clean the erogation valve (and the gun) by using Foam Dissolver.


chemical anchors

Vorpa FOAMFAST 750

Self-expanding special adhesive for rapid installation of exterior insulation finishing EPS panels. examples of application

technical data Code

3802

description

FOAMFAST FOR GUN

content ml

extrusion

pcs for box

750

For gun

12 pcs.

Content ml. 750 Status liquefied gas presure content Colour Yellow Specific weight (extruded) 25-30 kg/m3 Skin formation time (23°C, 50% H.R.) ca. 12 min. Shear strenght (depth 3 cm) ca. 40 min. Post expansion 5 % Shrinkage absent Tensile strenght (BS 5241) 11,1 N/cm2 Crush strenght (DIN 53421) 4 N/cm2 Thermal conductivity/20°C (DIN 52612) 0,03 W/(m°K) Acoustic insulation (EN ISO 717-1) 60 dB Temperature resistance -40 ÷ 90 °C Application temperature 5 ÷ 25 °C Flammable Class: (DIN 4102 - 1) B2 (EN 13501 - 1) E Storage The ideal storage temperature for canisters is between +10°C and +20°C. Canisters should be stored vertically, protected from heat and frost. 12 months in original, unopened packing at cool and dry place

88

Adhesive application on panels


Mechanical heavy duty anchors


through-setting heawy duty anchors

Vorpa VEX+SEISMIC Heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete

Cracked and non-cracked concrete

Product group Approved for • Cracked and non-cracked concrete M8-M27 • Reinforced and unreinforced normal weight concrete C20/25 - C50/60 • Anchorage under static, quasi/static actions M8-M27 • Seismic applications C1-C2 TR045 - M10 - M20 • Anchorage under fire exposure in standard TR 020 R30-R120

VEX+SEISMIC

VEX+SEISMIC (A4 Stainless Steel)

Also suitable for • Natural stone • Concrete C12/C15

European Technical Assesment ETAG 001 - PART 1 - 2 ANNEX E Option 1 - Cracked and non cracked concrete Seismic fixings - category C1-C2 annex E - TR045

R30-R120

Annex E -

Suitable to fix • Parapets • Steel beams • Machine tools • Industrial systems • Heavy duty metal constructions • Static, quasi/static anchorages • Structural fixings

As it can also be used on concrete with different strength characteristics, as specified in ETA, on compact natural stone and others materials (exception not included in ETA), specific on-site tests by the user are necessary

C1-C2

Product information Characteristics • Special wedge anchor assembled with hex nut and washer certified ETA-CE option1 and performance category C1-C2 under seismic action Benefit • Approved under the building regulations with a new European Technical Assessment (Option 1) • Approved for use in cracked and non-cracked concrete • Approved for use under seismic loading, performance categories C1 and C2 (M10 to M20, maximum anchor length 210 mm) • Suitable for use in compression resistant natural stone (without approval) • Two effective anchorage depths for greater flexibility (M8 to M16, maximum anchor length 210 mm) • Anchoring with the smaller effective anchorage depth reduces drilling and installation time. • Anchoring with the standard effective anchorage depth is suitable for the highest load limits

Benefit • Suitable for sprinkler system installations complying with VdS requirements • FM approval for the installation of sprinkler systems (M10 to M16) • Shock approval by the Swiss Federal office for Civil Protection Installation • Through-setting anchor Suggestion for use • Choose the most suitable accessory in relation to the application to carry out • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

• Suitable for surface, through, and stand-of fastening • Fire tested in compliance with DIN 4102-2. Fire resistance ratings R30–R120

90


through-setting heawy duty anchors

Vorpa VEX+SEISMIC Heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete

Cracked and non-cracked concrete

Installation sequence Installation instruction on concrete

Drill a hole into the concrete in rotary plus hammer mode

Remove the dust into the hole using a brush and a blowing pump

1)

Hammer the anchor into the hole

1)

Place the fixture

1) Through

fixing is allowed (place the fixture before placing the anchor)

Apply the required torque moment Tinst

Technical data VEX+SEISMIC zincplated

Code

**32101 **32102 **32103 **32104 32105 32106 32107 32108 32109 32110 32111 32112 32113 32114 32115 32116 32117 32118 32119 32120 32121 32122 32123 32124 32125

Description

Lt mm

hef/ hefrid mm

VEX+SEISMIC 8/6-60 VEX+SEISMIC 8/15-26-80 VEX+SEISMIC 8/30-41-95 VEX+SEISMIC 8/50-61-115 VEX+SEISMIC 10/10-30-90 VEX+SEISMIC 10/15-35-95 VEX+SEISMIC 10/20-40-100 VEX+SEISMIC 10/30-50-110 VEX+SEISMIC 10/50-70-130 VEX+SEISMIC 10/75-95-155 VEX+SEISMIC 10/100-120-180 VEX+SEISMIC 12/10-30-105 VEX+SEISMIC 12/15-35-110 VEX+SEISMIC 12/20-40-115 VEX+SEISMIC 12/30-50-125 VEX+SEISMIC 12/50-70-145 VEX+SEISMIC 12/65-85-160 VEX+SEISMIC 12/85-105-180 VEX+SEISMIC 12/105-125-200 VEX+SEISMIC 16/15-35-135 VEX+SEISMIC 16/25-45-145 VEX+SEISMIC 16/50-70-170 VEX+SEISMIC 16/80-100-200 VEX+SEISMIC 20/30-165 VEX+SEISMIC 20/60-195

60 80 95 115 90 95 100 110 130 155 180 105 110 115 125 145 160 180 200 135 145 170 200 165 195

-/35 46/35 46/35 46/35 60/40 60/40 60/40 60/40 60/40 60/40 60/40 70/50 70/50 70/50 70/50 70/50 70/50 70/50 70/50 85/65 85/65 85/65 85/65 100/100/-

d0xh1/ d0xh1rid Tfix1/ Tfix2 mm mm

Tinst Nm

Ch

8x60/8x49 8x60/8x49 8x60/8x49 8x60/8x49 10x75/10x55 10x75/10x55 10x75/10x55 10x75/10x55 10x75/10x55 10x75/10x55 10x75/10x55 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 16x110/16x90 16x110/16x90 16x110/16x90 16x110/16x90 20x125/20x125/-

20 20 20 20 25 25 25 25 25 25 25 45 45 45 45 45 45 45 45 90 90 90 90 160 160

13 13 13 13 17 17 17 17 17 17 17 19 19 19 19 19 19 19 19 24 24 24 24 30 30

** Not suitable for fixing Cat. C1 - C2

6/15/26 30/41 50/61 10/30 15/35 20/40 30/50 50/70 75/95 100/120 10/30 15/35 20/40 30/50 50/70 65/85 85/105 105/125 15/35 25/45 50/70 80/100 30/60/-

h1 = Min. hole depth Lt = Anchor length d0 = Hole diameter d = Screw diameter Tfix = Fixture thickness Tinst = Torque Ch = Spanner Lb = Stud length hef = Effective anchorage depth

* Annex E -

C1-C2

* R30-R120

* Only standard anchorage depth

91


through-setting heawy duty anchors

Vorpa VEX+SEISMIC Heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete

Cracked and non-cracked concrete

Technical data VEX+SEISMIC A4 Stainless Steel

Code

4662 4675 4676 4677 4678 4679 4680 4681 4682 4683 4684 4685 4686 4687 4688 4689 4690 4691 4692 4693 4694 4695

Description

Lt mm

hef/ hefrid mm

VEX+SEISMIC A4 10/10-30-90 VEX+SEISMIC A4 10/15-35-95 VEX+SEISMIC A4 10/20-40-100 VEX+SEISMIC A4 10/30-50-110 VEX+SEISMIC A4 10/50-70-130 VEX+SEISMIC A4 10/75-95-155 VEX+SEISMIC A4 10/100-120-180 VEX+SEISMIC A4 12/10-30-105 VEX+SEISMIC A4 12/15-35-110 VEX+SEISMIC A4 12/20-40-115 VEX+SEISMIC A4 12/30-50-125 VEX+SEISMIC A4 12/50-70-145 VEX+SEISMIC A4 12/65-85-160 VEX+SEISMIC A4 12/85-105-180 VEX+SEISMIC A4 12/105-125-200 VEX+SEISMIC A4 16/5-25-125 VEX+SEISMIC A4 16/15-35-135 VEX+SEISMIC A4 16/25-45-145 VEX+SEISMIC A4 16/50-70-170 VEX+SEISMIC A4 16/80-100-200 VEX+SEISMIC A4 20/30-165 VEX+SEISMIC A4 20/60-195

90 95 100 110 130 155 180 105 110 115 125 145 160 180 200 125 135 145 170 200 165 195

60/40 60/40 60/40 60/40 60/40 60/40 60/40 80/50 80/50 80/50 80/50 80/50 80/50 80/50 80/50 97/65 97/65 97/65 97/65 97/65 100/100/-

d0xh1/ d0xh1rid Tfix1/ Tfix2 mm mm

Tinst Nm

Ch

10x75/10x55 10x75/10x55 10x75/10x55 10x75/10x55 10x75/10x55 10x75/10x55 10x75/10x55 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 12x90/12x70 16x110/16x90 16x110/16x90 16x110/16x90 16x110/16x90 16x110/16x90 20x125/20x125/-

35 35 35 35 35 35 35 50 50 50 50 50 50 50 50 110 110 110 110 110 200 200

17 17 17 17 17 17 17 19 19 19 19 19 19 19 19 24 24 24 24 24 30 30

10/30 15/35 20/40 30/50 50/70 75/95 100/120 10/30 15/35 20/40 30/50 50/70 65/85 85/105 105/125 5/25 15/35 25/45 50/70 80/100 30/60/-

h1 = Min. hole depth Lt = Anchor length d0 = Hole diameter d = Screw diameter Tfix = Fixture thickness Tinst = Torque Ch = Spanner Lb = Stud length hef = Effective anchorage depth

* Annex E -

C1-C2

* R30-R120

* Only standard anchorage depth Examples of applications

92


through-setting heawy duty anchors

Vorpa VEX+SEISMIC Heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete

Cracked and non-cracked concrete

Installation data VEX+SEISMIC zincplated Anchor size Nominal drill hole diameter Torque moment Spanner Setting depth Minimum thickness of concrete member Drill hole depth Hole in the fixture

d0 Tinst SW hnom hmin h1 df

[mm] [Nm] [mm] [mm] [mm] [mm] [mm]

M8

M10

M12

M16

M20

M24

M27

8 20 13 46 100 60 9

10 25 17 60 120 75 12

12 45 19 70 140 90 14

16 90 24 85 170 110 18

20 160 30 100 200 125 22

24 200 36 115 230 145 26

28 300 41 125 250 160 30

M8

M10

M12

M16

M20

M24

M27

16 1,53 12,2 1,25 23 1,25 -

27 1,53 20,1 1,25 47 1,25 27 27 1,53 20 14 1,25

40 1,5 30 1,25 82 1,25 40 40 1,5 27 16,2 1,25

60 1,5 55 1,25 216 1,25 60 60 1,5 44 35,7 1,25

86 1,6 69 1,33 363 1,33 86 86 1,6 69 55,2 1,33

126 1,5 114 1,25 898 1,25 -

196 1,5 169,4 1,25 1331,5 1,25 -

12 5 -

16 9 9 3,6

25 16 16 10,2

35 25 25 13,8 1,22 1,41 1,55

1) 1) 36 22,4

1) 1) -

1) 1) -

46 138 69

60 180 90

70 210 105

85 255 127,5 7,2 10,1

100 300 150

115 345 172,5

125 375 187,5

Design method according to ETAG 001 part 1-2 Annex E Anchor size Steel failure Characteristic resistance Tension Partial safety factor Shear Partial safety factor Bending moment Partial safety factor Tension loads C1 Tension loads C2 Partial safety factor Shear loads C1 Shear loads C1 Partial safety factor Pull-out failure Characteristics resistance non cracked concrete C20/25 Characteristics resistance cracked concrete C20/25 Characteristics resistance seismic performance C1 Characteristics resistance seismic performance C2 C30/37 Increasing factor C40/50 C50/60 Concrete cone failure and Anchorage depth

K factor cracked concrete K factor non-cracked concrete

NRk,s YMs VRk,s YMs M0Rk,s YMs NRk,s, C1 NRk,s, C2 YMs, seis VRk, seis, C1 VRk, seis, C2 YMs, seis

[kN] [kN] [Nm] [kN] [kN] [kN] [kN]

NRk,p,ucr NRk,p,cr NRk,seis,C1 NRk,seis,C2

[kN] [kN] [kN] [kN]

Ďˆc

[-]

hef scr,sp ccr,sp k k

[mm] [mm] [mm]

1) Pull out it not decisive

93


through-setting heawy duty anchors

Vorpa VEX+SEISMIC Heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete

Cracked and non-cracked concrete

Installation data VEX+SEISMIC A4 stainless steel Anchor size Nominal drill hole diameter Torque moment Spanner Standard sett. depth Minimum thickness of concrete member Drill hole depth Hole in the fixture

d0 Tinst SW hnom hmin h1 df

[mm] [Nm] [mm] [mm] [mm] [mm] [mm]

M8

M10

M12

M16

M20

M24

M27

8 20 13 46 100 60 9

10 35 17 60 120 75 12

12 50 19 70 140 90 14

16 110 24 85 160 110 18

20 200 30 100 200 125 22

24 290 36 125 250 155 26

-

M8

M10

M12

M16

M20

M24

M27

16 1,5 13 1,0 26 1,25 -

27 1,5 20 1,0 52 1,25 27 27 1,5 20 14 1,25

40 1,5 30 1,0 92 1,25 40 40 1,5 27 16,2 1,25

64 1,5 55 1,0 200 1,25 64 64 1,5 44 35,7 1,25

108 1,68 86 1,0 454 1,4 108 108 1,68 69 55,2 1,4

110 1,5 123,6 1,0 785,4 1,25 -

-

12 5 -

16 9 -

25 16 -

35 25 1,22 1,41 1,55

1) 1) -

1) 40 -

-

46 138 69

60 180 90

70 210 105

85 255 127,5 7,2 10,1

100 300 150

125 375 187,5

-

Design method according to ETAG 001 part 1-2 Annex E Anchor size Steel failure Characteristic resistance Tension Partial safety factor Shear Partial safety factor Bending moment Partial safety factor Tension loads C1 Tension loads C2 Partial safety factor Shear loads C1 Shear loads C1 Partial safety factor Pull-out failure Characteristics resistance non cracked concrete C20/25 Characteristics resistance cracked concrete C20/25 Characteristics resistance seismic performance C1 Characteristics resistance seismic performance C2 C30/37 Increasing factor C40/50 C50/60 Concrete cone failure and Anchorage depth

K factor cracked concrete K factor non-cracked concrete

NRk,s YMs VRk,s YMs M0Rk,s YMs NRk,s, C1 NRk,s, C2 YMs, seis VRk, seis, C1 VRk, seis, C2 YMs, seis

[kN] [kN] [Nm] [kN] [kN] [kN] [kN]

NRk,p,ucr NRk,p,cr NRk,seis,C1 NRk,seis,C2

[kN] [kN] [kN] [kN]

Ďˆc

[-]

hef scr,sp ccr,sp k k

[mm] [mm] [mm]

1) Pull out it not decisive

94


through-setting heawy duty anchors

Vorpa VEX+SEISMIC Heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete

Cracked and non-cracked concrete

Installation data VEX+SEISMIC reduced anchorage depth fixings M8

M10

M12

M16

8 20 13 35 80 49 9

10 35 17 40 80 55 12

12 50 19 50 100 70 14

16 110 24 65 140 90 18

M8

M10

M12

M16

50 60 40 185

50 100 65 180

50 160 100 185

65 170 170 65

Smin per C≥ Cmin per S≥

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

50 60 40 85

50 100 65 180

50 160 65 250

65 170 100 250

NRk,p,rid

[kN]

5

7,5

1)

1)

50

65

1)

1)

50

65

Anchor size Nominal drill hole diameter Torque moment Spanner Standard sett. depth Minimum thickness of concrete member Drill hole depth Hole in the fixture

d0 Tinst SW hnom,rid hmin h1rid df

[mm] [Nm] [mm] [mm] [mm] [mm] [mm]

M20

M24

M27

M20

M24

M27

Minimum spacing and edge distance reduced anchorage depth Anchor size Non cracked concrete Minimum spacing Minimum edge distance Cracked concrete Minimum spacing Minimum edge distance

Cracked concrete Pull-out failure Characteristic resistance C30/37 Increasing factor C40/50 C50/60 Concrete cone failure Anchorage depth K factor Non-cracked concrete Pull-out failure Characteristic resistance C30/37 Increasing factor C40/50 C50/60 Concrete cone failure Anchorage depth K factor

Smin per C≥ Cmin per S≥

1,22 1,41 1,55

ψc hef, rid

35

40

k

7,2

NRk,p,rid

7,5

9 1,22 1,41 1,55

ψc hef, rid

35

k

40 10,1

1) Pull out is not decisive ATTENTION: Partial technical data. Please consult ETA annexes to verify complete values.

95


through-setting heawy duty anchors

Vorpa VEX+SEISMIC Heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete

Cracked and non-cracked concrete

Installation data VEX+SEISMIC Characteristic values for tension and shear load under fire exposure standard anchorage depth, cracked and non-cracked concrete C20/25 to C50/60, design acc. to TR 020 or CEN/TS 1192-4, Annex D Anchor size Tension load Steel failure Steel zinc plated R30 R60 R90 R120 Stainless steel A4 R30 R60 R90 R120 Shear load Steel failure without lever arm Steel zinc plated R30 R60 R90 R120 Stainless steel A4 R30 R60 R90 R120 Bending moment Steel failure with lever arm Steel zinc plated R30 R60 R90 R120 Stainless steel A4 R30 R60 R90 R120

NRk,s, fi

NRk,s, fi

VRk,s, fi

VRk,s, fi

o

M Rk,s, fi

o

M Rk,s, fi

M8

M10

M12

M16

M20

M24

M27

[kN]

1,4 1,1 0,8 0,7

2,2 1,8 1,4 1,2

3,2 2,8 2,4 2,2

6,0 5,2 4,4 4,0

9,4 8,2 6,9 6,3

13,6 11,8 10,0 9,1

17,6 15,3 13,0 11,8

[kN]

3,8 2,9 2,0 1,6

6,9 5,2 3,5 2,7

11,5 8,6 5,6 4,2

21,5 16 10,5 7,8

33,5 25,0 16,4 12,1

48,2 35,9 23,6 17,4

[kN]

1,6 1,5 1,2 1,0

2,6 2,5 2,1 2,0

3,8 3,6 3,5 3,4

7,0 6,8 6,5 6,4

11 11 10 10

16 15 15 14

[kN]

3,8 2,9 2,0 1,6

6,9 5,2 3,5 2,7

11,5 8,6 5,6 4,2

21,5 16 10,5 7,8

33,5 25,0 16,4 12,1

48,2 35,9 23,6 17,4

[Nm]

1,7 1,6 1,2 1,1

3,3 3,2 2,7 2,5

5,9 5,6 5,4 5,3

15 14 14 13

29 28 27 26

50 48 47 46

[Nm]

3,8 2,9 2,1 1,6

9,0 6,8 4,5 3,4

17,9 13,3 8,8 6,5

45,5 33,9 22,2 16,4

88,8 66,1 43,4 32,1

153,5 114,3 75,1 55,5

96

20,6 19,8 19,0 18,6

75 72 69 68


through-setting heawy duty anchors

Vorpa VE.1CE heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete

Cracked and non cracked concrete

Products group

ETA-19/0885 ETAG 1 Option 1 for cracked concrete

Approved for • Cracked and non-cracked concrete • Static and quasi static loads M8-M20 • Seismic applications C1 - M12 - M16 • Anchorage under fire exposure in standard TR 020 R30-R120

R30-R120

EAD 330232 - 00 - 0601 Option 1 - Cracked and non cracked concrete Seismic fixings - category C1- M12-M16

Suitable to fix • Parapets • Steel beams • Machine tools • Industrial systems • Heavy duty metal constructions • Structural fixings • Seismic application M12-M16

Also suitable for • Natural stone • Concrete C12/C15

FIXING IN SEISMIC Annex E-C1

As it can also be used on concrete with different strength characteristics, as specified in ETA, on compact natural stone and others materials (exception not included in ETA), specific on-site tests by the user are necessary

Product information Installation • Through-setting anchor

Characteristics • Special wedge anchor assembled with hex nut and washer certified ETA-CE option 1 and performance category C1 under seismic action. Benefits • European Technical Approval - Option 1 cat. C1 • High Performance in cracked and non-cracked concrete • Easy installation: just few turns ensures the required installation torque • Fire resistance R30-R120 according to Technical Report TR 020 • Fast and precise installation thanks to be coloured ring (overall anchor embedment depth in the concrete)

Suggestion for use • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

Installation sequence Installation instruction for static and quasi-static loads

Drill a hole into the concrete in rotary plus hammer mode

Remove the dust into the hole using a brush and a blowing pump

1)

Hammer the anchor into the hole

1) Through

fixing is allowed (place the fixture before placing the anchor)

Apply the required torque moment Tinst

97

1)

Place the fixture


through-setting heawy duty anchors

Vorpa VE.1CE heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete

Cracked and non cracked concrete

Technical data

hef

Code

Description

Lt mm

hef mm

d0 x h1 mm

Tfix max mm

Tinst Nm

Ch

92101 92102 92103 92104 92105 92106 92107 92108 92109 92110 92111 92112 92113 92114 92115 92116 92117 92118 92119 92120

VE.1CE 8/5 - 60 VE.1CE 8/20 - 75 VE.1CE 8/40 - 95 VE.1CE 8/60 - 115 VE.1CE 8/75 - 130 VE.1CE 10/10 - 90 VE.1CE 10/20 - 100 VE.1CE 10/30 - 110 VE.1CE 10/40 - 120 VE.1CE 10/80 - 160 VE.1CE 10/100 - 180 VE.1CE SEISMIC 12/5 - 90 VE.1CE SEISMIC 12/20 - 105 VE.1CE SEISMIC 12/35 - 120 VE.1CE SEISMIC 12/50 - 135 VE.1CE SEISMIC 12/80 - 165 VE.1CE SEISMIC 12/100 - 185 VE.1CE SEISMIC 16/15 - 125 VE.1CE SEISMIC 16/40 - 150 VE.1CE SEISMIC 16/100 - 210

60 75 95 115 130 90 100 110 120 160 180 90 105 120 135 165 185 125 150 210

40 40 40 40 40 60 60 60 60 60 60 60 60 60 60 60 60 80 80 80

8x55 8x55 8x55 8x55 8x55 10x75 10x75 10x75 10x75 10x75 10x75 12x75 12x75 12x75 12x75 12x75 12x75 16x100 16x100 16x100

5 20 40 60 75 10 20 30 40 80 100 5 20 35 50 80 100 15 40 100

30 30 30 30 30 50 50 50 50 50 50 70 70 70 70 70 70 130 130 130

13 13 13 13 13 17 17 17 17 17 17 19 19 19 19 19 19 24 24 24

Examples of applications

98

Lt

h1 = Min. hole depth Lt = Anchor length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness Tinst = Torque Ch = Spanner hef = Anchorage depth


through-setting heawy duty anchors

Vorpa VE.1CE heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete

Cracked and non cracked concrete

Installation data Declaration of performance VE.1CE Anchor size Nominal drill hole diameter Maximum cutting diameter of drill bit Installation torque moment Minimum allowable spacing (even in case of fire exposure) Minimum allowable edge distance Wrench size Minimum thickness of concrete member Depth of the drilled hole to deepest point Diameter of clearance hole in the fixture Thickness of fixture

d0 dcut Tinst Smin Cmin SW hmin h1 df tfix

[mm] [mm] [Nm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

M8

M10

M12

M16

8 8,45 30 65 65 13 100 55 9 75

10 10,45 50 150 60 17 120 75 12 100

12 12,5 70 80 80 19 120 75 14 100

16 16,5 130 85 85 24 160 100 18 100

M8

M10

M12

M16

31,6

43,4

75,4

24,7 76,6

45,9 194,8

12 12

35 12

Declared performance according to ETAG001 part 1, part 2 and Annex E Anchor size Steel failure NRk,s ɣms VRk,s M0Rk,s YMs,N

[kN] [-] [kN] [Nm] [-]

22,2

NRk,p,ucr NRk,p,cr

[kN] [kN]

6 3

ψc

[-]

Y2

[-]

1,2

1,2

1,4

1,4

hef Scr,N ccr,N Scr,sp ccr,sp

[mm] [mm] [mm] [mm] [mm]

40 120 60 200 100

60 180 90 300 150

60 180 90 360 180

80 240 120 400 200

Concrete pry-out failure K factor

k

[-]

1,0

2,0

2,0

2,00

Concrete edge failure Effective length of anchor Outside diameter of anchor Installation safety factor

lf = hef dnom ɣ2

[mm] [mm] [-]

40 8

60 10

60 12

80 16

Installation safety factor Characteristic resistance Partial safety factor Pull-out failure Characteristic resistance in uncracked concrete C20/25 Characteristic resistance in cracked concrete C20/25 C30/37 Increasing factor for concrete C40/50 C50/60 Installation safety factor Concrete cone failure and splitting failure Effective anchorage depth Critical spacing for concrete cone failure Critical edge distance for concrete cone failure Critical spacing for splitting failure Critical edge distance for splitting failure

99

1,88 8,1 22,8

17,6 45,5 1,25

12 9 1,22 1,41 1,55

1,0


through-setting heawy duty anchors

Vorpa VE.1CE heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete

Cracked and non cracked concrete

Installation data Declared performance according to EAD 330232-00-0601 part 1, part 2 and Annex E Anchor size

M8

M10

M12

M16

Steel Failure under fire exposure in concrete C20/25 to C50/60 Characteristic resistance to tension and shear loads

Characteristic bending moments

R30 R60 R90 R120 R30 R60 R90 R120

FRk,s,fi,30 FRk,s,fi,60 FRk,s,fi,90 FRk,s,fi,120 M0Rk,s,fi,30 M0Rk,s,fi,60 M0Rk,s,fi,90 M0Rk,s,fi,120

[kN] [kN] [kN] [kN] [Nm] [Nm] [Nm] [Nm]

0,4 0,3 0,3 0,2 0,4 0,3 0,3 0,2

0,9 0,8 0,6 0,5 1,1 1,0 0,7 0,6

1,7 1,3 1,1 0,8 2,6 2,0 1,7 1,3

3,1 2,4 2,0 1,6 6,7 5,0 4,3 3,3

R 30 to R 90 R 120

NRk,p,fi NRk,p,fi 120

[kN] [kN]

0,8 0,6

2,3 1,8

3,0 2,4

4,0 3,2

R 30 to R 90 R 120

NRk,c,fi NRk,c,fi 120

[kN] [kN]

1,8 1,5

5,0 4,0

5,0 4,0

10,3 8,2

Pull-out failure Characteristic resistance Concrete cone failure Characteristic resistance

Characteristic values of resistance under tension loads in case of seismic performance category C1 for design acc. to TR045 Anchor size

M16

M12

Steel failure Characteristic resistance Partial safety factor

NRk,s,seis ɣMs,seis

[kN] [-]

43,4

Pullout failure Characteristic resistance Partial safety factor

NRk,p,seis ɣ2 = ɣinst

[kN] [-]

12

75,4 1,881)

12 1,4

Characteristic values of resistance under shear loads in case of seismic performance category C1 for design acc. to TR045 Anchor size Steel failure without lever arm Characteristic resistance Partial safety factor

M16

M12

VRk,s,seis ɣMs,seis

[kN] [-]

1) In absence of other national regulations

100

24,8

13,6 1,251)


through-setting heawy duty anchors

Vorpa VE.7CE

Steel anchors with ETA option 7 for non-cracked concrete

Non-cracked concrete

Products group Approved for • Non-cracked concrete • Static and quasi static loads M6-M16

VE.7CE

Also suitable for • Natural stone • Concrete C12/C15

European Technical Approval Option 7 for non-cracked concrete

As it can also be used on concrete with different strength characteristics, as specified in ETA, on compact natural stone and others materials (exception not included in ETA), specific on-site tests by the user are necessary

To fix • Plants engineering • Heavy structural works • Metal structures • Profiles • Gates • Stairs • Parapets

Software Vorpa Calcul Anchor

Product information Characteristics • High performances through steel anchor composed of steel pin, nut, washer and expansion clip. • When the hexagonal nut is tightened, the tapered bolt is pulled into the expansion clip and expands it against the drill hole wall. Benefits • Reduced hole diameter • Suitable for through-setting applications in concrete • Thread diameter and hole diameter are the same • Reinforced anchor’s head to avoid damaging the thread during the installation

Benefits • Special designed expansion clip granting a smooth expansion and avoiding the rotation of the anchor during the installation Installation • Through-setting anchor Suggestion for use • Choose the right size of the anchor related to the object to be fixed • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

Installation sequence

Examples of applications

101


through-setting heawy duty anchors

Vorpa VE.7CE

Steel anchors with ETA option 7 for non-cracked concrete

Non-cracked concrete

Technical data

VE.7CE

Code

4637 4638 4639 4640 4641 4642 4643 4644 4645 4646 4696 4647 4648 4649 4650 4651 4652 4653 4654 4655 4656 4657 4658 4659

Description

Lt mm

d0 mm

h1 mm

VE.7CE 6/ 10-55 VE.7CE 6/ 20-65 VE.7CE 8/ 1-55 VE.7CE 8/ 1-65 VE.7CE 8/ 15-80 VE.7CE 8/ 30-95 VE.7CE 8/ 50-115 VE.7CE 8/ 65-130 VE.7CE 10/ 1-75 VE.7CE 10/ 15-105 VE.7CE 10/ 25-105 VE.7CE 10/ 45-120 VE.7CE 10/ 75-150 VE.7CE 12/ 10-90 VE.7CE 12/ 15-110 VE.7CE 12/ 25-120 VE.7CE 12/ 45-140 VE.7CE 12/ 65-160 VE.7CE 12/ 85-180 VE.7CE 16/ 5-125 VE.7CE 16/ 20-140 VE.7CE 16/ 30-150 VE.7CE 16/ 55-175 VE.7CE 16/ 100-220

55 65 55 65 80 95 115 130 75 105 105 120 150 90 110 120 140 160 180 125 140 150 175 220

6 6 8 8 8 8 8 8 10 10 10 10 10 12 12 12 12 12 12 16 16 16 16 16

55 55 65 65 65 65 65 65 70 70 70 70 70 90 90 90 90 90 90 110 110 110 110 110

** **

**

**

tfix max mm

10 20 1 ** 1 ** 15 30 50 65 1 ** 15 25 45 75 10 ** 15 25 45 65 85 5 20 30 55 100

Tinst Nm

Ch

5 5 15 15 15 15 15 15 25 25 25 25 25 45 45 45 45 45 45 100 100 100 100 100

10 10 13 13 13 13 13 13 17 17 17 17 17 19 19 19 19 19 19 24 24 24 24 24

The letter on the top of the head indicated the anchors lenght.

Lettera ≥ < Lettera ≥ <

A 50 N 170 180

B 50 60 O 180 190

C 60 70 P 190 200

D 70 80 Q 200 220

E 80 90 R 220 240

F 90 10 S 240 260

G 100 110 T 260 280

H 110 120 U 280 300

I 120 130 V 300 320

102

J 130 140 W 320 340

K 140 150 X 340 360

L 150 160 Y 360 380

M 160 170 Z 380 400

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner

** Reduced anchorage depth - not included in European Technical Approval


through-setting heawy duty anchors

Vorpa VE.7CE

Steel anchors with ETA option 7 for non-cracked concrete

Non-cracked concrete

Installation data Anchor type Installation data VE.7CE Anchor diameter Effective anchorage depth Drill hole diameter Drill hole depth Hole diameter in the fixture Torque moment Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum thickness member Characteristic values Pull out failur non cracked concrete Ψc C30/37 Ψc C40/50 Ψc C50/60

M6

M8

M10

M12

M16

d hef d0 h1 df Tinst Scr,N Ccr,N Smin Cmin hmin

mm mm mm mm mm mm Nm mm mm mm mm

6 40 6 55 7 5 120 60 60 60 100

8 45 8 65 9 15 135 70 67,5 67,5 100

10 51 10 70 12 25 155 80 76,5 76,5 105

12 66 12 90 14 45 200 100 99 99 135

16 80 16 110 18 100 240 120 120 120 160

Nrk,P C20/25

KN

4 1,08 1,15 1,19

9 1,08 1,15 1,19

12 1,08 1,15 1,19

16 1,08 1,15 1,19

30 1,08 1,15 1,19

4 6,1

7,3 15

11,6 29,9

16,9 52,4

31,4 133,2

2,6 3,2 4,8

6 5,8 12

8 9,2 23,9

8,8 13,5 41,9

16,6 25,1 106,5

1,8 2,2 3,4

4,2 4,1 8,5

5,7 6,5 17

6,2 9,6 29,9

11,8 17,9 76

VRk,S C20/25 Shear failure KN MRK,S Bending moment Nm Values where the reduction factor γ is included (Design loads) Nrk,P Pull out failure KN VRk,S Shear failure KN MRK,S Bending moment Nm Recommended loads N Pull out failure KN T Shear failure KN M Bending moment Nm

103


through-setting heawy duty anchors

Vorpa VE.7CE INOX A4

Steel anchors with ETA option 7 for non-cracked concrete

Non-cracked concrete

Products group VE.7CE INOX A4 (A4 stainless steel)

Approved for • Non-cracked concrete • Static and quasi static loads M6-M20 • Anchorage under fire exposure in standard TR 020 R30-R120

European Technical Approval Option 7 for non-cracked concrete

As it can also be used on concrete with different strength characteristics, as specified in ETA, on compact natural stone and others materials (exception not included in ETA), specific on-site tests by the user are necessary

To fix • Plants engineering • Heavy structural works • Metal structures • Profiles • Gates • Stairs • Parapets

Also suitable for • Natural stone • Concrete C12/C15

Software Vorpa Calcul Anchor

Product information Characteristics • High performances through steel anchor composed of steel pin, nut, washer and expansion clip. • When the hexagonal nut is tightened, the tapered bolt is pulled into the expansion clip and expands it against the drill hole wall. Benefits • Reduced hole diameter • Suitable for through-setting applications in concrete • Thread diameter and hole diameter are the same • Reinforced anchor’s head to avoid damaging the thread during the installation

Benefits • Special designed expansion clip granting a smooth expansion and avoiding the rotation of the anchor during the installation Installation • Through-setting anchor Suggestion for use • Choose the right size of the anchor related to the object to be fixed • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

Installation sequence

Examples of applications

104


through-setting heawy duty anchors

Vorpa VE.7CE INOX A4

Steel anchors with ETA option 7 for non-cracked concrete

Non-cracked concrete

Technical data

VE.CE 7 INOX A4 (A4 Stainless Steel) Code

4620 4621 4622 4623 4624 4625 4626 4627 4628 4629 4630 4631 4632 4633 4634 4635 4636

Description

Lt mm

VE.7CE A4 8/50-5 VE.7CE A4 8/75-10-19 VE.7CE A4 8/95 -30-39 VE.7CE A4 8/120-55-64 VE.7CE A4 10/60-10 VE.7CE A4 10/90-15-21 VE.7CE A4 10/120-45-51 VE.7CE A4 10/145-70-76 VE.7CE A4 12/75-5 VE.7CE A4 12/110-15-30 VE.7CE A4 12/125-30-45 VE.7CE A4 12/145-50-65 VE.7CE A4 16/115-14 VE.7CE A4 16/150-30-46 VE.7CE A4 16/180-60-76 VE.7CE A4 20/150-5-27 VE.7CE A4 20/180-35-57

50 75 95 120 60 90 120 145 75 110 125 145 115 150 180 150 180

d0 mm

8 8 8 8 10 10 10 10 12 12 12 12 16 16 16 20 20

h1 /h1rid mm

-/45 65/55 65/55 65/55 -/50 70/65 70/65 70/65 -/65 90/75 90/75 90/75 -/95 110/95 110/95 130/110 130/110

tfix / tfix2 mm

-/5 10/19 30/39 55/64 -/10 15/21 45/51 70/76 -/5 15/30 30/45 50/65 -/14 30/46 60/76 5/27 35/57

Attention: The use of the Tfix2 causes reduced effective anchorage depth and reduced loads

Examples of applications

105

Tinst Nm

Ch

15 15 15 15 25 25 25 25 50 50 50 50 100 100 100 160 160

13 13 13 13 17 17 17 17 19 19 19 19 24 24 24 30 30

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner


through-setting heawy duty anchors

Vorpa VE.7CE INOX A4

Steel anchors with ETA option 7 for non-cracked concrete

Non-cracked concrete

Installation data Anchor type Installation data Performance data Effective anchorage depth Reduced anchorage depth Drill hole diameter Drill hole diameter in the fixture Drill hole depth Torque moment Width across nut

hef hef,red d0 d0 h1 Tinst SW

Spacing and edge distance Effective anchorage depth Characteristic spacing Characteristic edge distance Minimum spacing Minimum edge distance Minimum thickness of concrete slab

hef Scr,N Ccr,N Smin Cmin hmin

Characteristic values - Effective anchorage depth (hef) Pull out failure C25/30 Ψc C30/37 Ψc C40/50 Ψc C20/60 V Shear failure M Bending moment Design loads - Effective anchorage depth (hef) N Pull out failure V Shear failure M Bending moment Recommended loads N Pull out failure V Shear failure M Bending moment 1) Application

M8

M10

M12

M16

M20

mm mm mm mm mm Nm mm

44 - - 351) 8 8 9 9 65 55 15 15 13 13

48 - - 42 10 10 12 12 70 65 25 25 17 17

65 - - 50 12 12 14 14 90 75 50 50 19 19

80 - - 64 16 16 18 18 110 95 100 100 24 24

100 - - 78 20 20 22 22 130 110 160 160 30 30

mm mm mm mm mm mm

44 351) 132 105 66 52,5 35 60 45 60 100 80

48 42 144 126 72 63 45 55 55 65 100 100

65 50 195 150 97,5 75 60 100 70 100 130 100

82 64 246 192 123 96 80 110 80 110 160 130

100 78 300 234 150 117 100 140 100 140 200 160

kN Nm

kN kN Nm kN kN Nm

M8 9 1,22 1,41 1,55 12 24

M10 12 1,22 1,41 1,55 19 49

M12 20 1,22 1,41 1,55 27 85

M16 30 1,22 1,41 1,55 50 199

M20 40 1,22 1,41 1,55 86 454

M8 6 9,6 19,2 M8 4,2 6,8 13,7

M10 8 15,2 39,2 M10 5,7 10,8 28

M12 13,3 21,6 68 M12 9,5 15,4 48

M16 20 40 159,2 M16 14,2 28,5 113,5

M20 26,6 61,4 324,2 M20 19 43,8 231

limited to statically indeterminated systems.

106


through-setting heawy duty anchors

Vorpa VE.A Steel anchors

Non-cracked concrete

Products group VE.A

Suitable for • Non-cracked concrete

VE.A ZF / VE.A ZG hot dip galvanized Geomet galvanized

VE.A INOX A2 (A2 stainless steel)

To fix • Steel beams • Sections • Plates • Heavy structural works • Plants engineering • Railings and balustrades • Gates

Test reports available

VE.A INOX A4 (A4 stainless steel)

Software Vorpa Calcul Anchor

VE.A M internal thread VE.A M INOX A2 internal thread (A2 stainless steel)

[*] Option 7 for non-cracked concrete

[*] VE.CE 7 Ø16 extralong fixings

Examples of applications

Installation sequence

107


through-setting heawy duty anchors

Vorpa VE.A Steel anchors

Non-cracked concrete

Product information Characteristics • Through steel anchor composed of steel pin, nut, washer and expansion clip. The version with internal thread VE.A M to be used with bolts of any metrical length. • When the hexagonal nut is tightened, the tapered bolt is pulled into the expansion clip and expands it against the drill hole wall. Benefits • Thread diameter and hole diameter are the same • Reinforced anchor’s head to avoid damaging the thread during the installation • Anti-rotation during the installation procedure and smooth expansion thanks to the particular shape of the clip

Benefits • High load values and fast setting • Hot dip galvanized version VE.A ZF and Geomet galvanized VE.A ZG for outdoor use and damp conditions Installation • Through-setting anchor Suggestion for use • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

Technical data

VE.A

Code

1601 1646TW 1602 1625 1603 1639 1604 51604 1605 1618 1606 51605 51606 51607 51609 1607 51608 1608 5626 1609 1614 1641 1643 1610 1626 5611 1611 1640 1612 1627 1613 1637 5621 5622 5623

Description

Lt mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Ch

VE.A 6/5-45 VE.A 6/7-55 VE.A 6/10-65 VE.A 6/25-80 VE.A 6/40-100 VE.A 6/70-130 VE.A 8/5-55 VE.A 8/10-60 VE.A 8/15-75 VE.A 8/25-90 VE.A 8/50-115 VE.A 8/70-130 VE.A 8/100-160 VE.A 8/120-180 VE.A 8/140-200 VE.A 10/5-65 VE.A 10/10-80 VE.A 10/20-90 VE.A 10/30-100 VE.A 10/50-120 VE.A 10/70-140 VE.A 10/100-170 VE.A 10/140-210 VE.A 12/10-75 VE.A 12/15-90 VE.A 12/20-100 VE.A 12/20-110 VE.A 12/30-120 VE.A 12/50-145 VE.A 12/65-160 VE.A 12/85-180 VE.A 12/100-200 VE.A 14/15-110 VE.A 14/30-145 VE.A 14/60-175

45 55 65 80 100 130 55 60 75 90 115 130 160 180 200 65 80 90 100 120 140 170 210 75 90 100 110 120 145 160 180 200 110 145 175

6 6 6 6 6 6 8 8 8 8 8 8 8 8 8 10 10 10 10 10 10 10 10 12 12 12 12 12 12 12 12 12 14 14 14

35 40 50 50 55 55 40 40 55 55 55 55 55 55 55 50 60 60 60 60 60 60 60 55 65 80 80 80 85 85 85 85 85 110 105

5 7 10 25 40 70 5 10 15 25 50 70 100 120 140 5 10 20 30 50 70 100 140 10 15 20 20 30 50 65 85 100 15 30 60

10 10 10 10 10 10 20 20 20 20 20 20 20 20 20 45 45 45 45 45 45 45 45 65 65 65 65 65 65 65 65 65 85 85 85

10 10 10 10 10 10 13 13 13 13 13 13 13 13 13 17 17 17 17 17 17 17 17 19 19 19 19 19 19 19 19 19 22 22 22

108

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner

Follows on the next page


through-setting heawy duty anchors

Vorpa VE.A Steel anchors

Non-cracked concrete

Technical data

VE.A

Code

1629 1615 1636 1616 1620 1638 1617 1624 618 1644 619 1628 1619 1642

Description

Lt mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Ch

VE.A 16/5-90 VE.A 16/10-110 VE.A 16/20-125 VE.A 16/30-145 VE.A 16/60-175 VE.A 16/90-200 VE.A 16/105-220 VE.A 20/15-145 VE.A 20/30-170 VE.A 20/60-200 VE.A 20/80-220 VE.A 20/130-270 VE.A 24/25-180 VE.A 24/100-260

90 110 125 145 175 200 220 145 170 200 220 270 180 260

16 16 16 16 16 16 16 20 20 20 20 20 24 24

70 85 90 100 100 100 100 110 120 120 120 120 135 135

5 10 20 30 60 90 105 15 30 60 80 130 25 100

115 115 115 115 115 115 115 200 200 200 200 200 320 320

24 24 24 24 24 24 24 30 30 30 30 30 36 36

Tinst Nm

Ch

20 20 20 40 40 40 50 50 50 125 125 250 320

13 13 13 17 17 17 19 19 19 24 24 30 36

20 20 20 20 40 40 40 50 50 50 125 125 250 320

13 13 13 13 17 17 17 19 19 19 24 24 30 36

VE.A ZF hot dip galvanized

Code

4604 4605 4606 4607 4608 4609 4611 4612 4613 4615 4616 4618 4619

Description

VE.A ZF VE.A ZF VE.A ZF VE.A ZF VE.A ZF VE.A ZF VE.A ZF VE.A ZF VE.A ZF VE.A ZF VE.A ZF VE.A ZF VE.A ZF

8/3-65 8/10-80 8/30-100 10/5-80 10/15-90 10/45-120 12/20-110 12/50-145 12/90-180 16/10-125 16/35-150 20/30-160 24/20-180

Lt mm

d0 mm

h1 mm

65 80 100 80 90 120 110 145 180 125 150 160 180

8 8 8 10 10 10 12 12 12 16 16 20 24

40 55 55 50 60 60 80 80 80 85 100 120 135

tfix max mm

3 10 30 5 15 45 20 50 90 10 35 30 20

VE.A ZG Geomet galvanized

54604 54605 54606 54620 54607 54617 54621 54611 54612 54622 54615 54616 54618 54619

VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG VE.A ZG

8/3-65 8/10-80 8/30-100 8/15-115 10/5-80 10/15-90 10/45-120 12/20-110 12/50-145 12/90-180 16/10-125 16/35-150 20/30-160 24/20-180

65 80 100 115 80 90 120 110 145 180 125 150 160 180

8 8 8 8 10 10 10 12 12 12 16 16 20 24

40 55 55 55 50 60 60 80 80 80 85 100 120 135

3 10 30 15 5 15 45 20 50 90 10 35 30 20

109

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner


through-setting heawy duty anchors

Vorpa VE.A Steel anchors

Non-cracked concrete

Technical data

VE.A INOX A2 (A2 Stainless Steel)

Code

Description

Lt mm

d0 mm

h1 mm

2601 2600 2602 2603 2604 2605 2618 2627 2606 2607 2617 2608 2609 2610 2613 5607 5608 2611 2630 2611S 2612 2629 2615 2619 2616 2620 2621 2622

VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2 VE.A A2

45 55 65 85 55 75 90 95 115 65 75 90 120 75 80 90 100 110 120 130 145 90 110 125 145 175 160 180

6 6 6 6 8 8 8 8 8 10 10 10 10 12 12 12 12 12 12 12 12 16 16 16 16 16 20 20

30 45 50 60 40 55 55 55 55 50 60 60 60 55 50 80 80 80 80 85 85 70 75 75 100 100 120 120

6/10-45 6/5-55 6/10-65 6/20-85 8/5-55 8/15-75 8/25-90 8/30-95 8/50-115 10/5-65 10/10-75 10/20-90 10/50-120 12/10-75 12/20-80 12/15-90 12/20-100 12/20-110 12/30-120 12/35-130 12/50-145 16/5-90 16/20-110 16/35-125 16/30-145 16/65-175 20/20-160 20/40-180

tfix max mm

10 5 10 20 5 15 25 30 50 5 10 20 50 10 20 15 20 20 30 35 50 5 20 35 30 65 20 40

Tinst Nm

Ch

10 10 10 10 20 20 20 20 20 45 45 45 45 65 65 65 65 65 65 65 65 115 115 115 115 115 200 200

10 10 10 10 13 13 13 13 13 17 17 17 17 19 19 19 19 19 19 19 19 24 24 24 24 24 28 28

Tinst Nm

Ch

10 10 20 20 20 20 20 20 45 45 45 45 45 45 45

10 10 13 13 13 13 13 13 17 17 17 17 17 17 17

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner

VE.A INOX A4 (A4 Stainless Steel)

Code

Description

Lt mm

d0 mm

13750 13751 13752 13753 13774 13765 13780 13754 13755 13776 13756 13781 13757 13766 13775

VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4 VE.A A4

55 85 65 80 105 115 120 130 65 80 90 100 120 130 140

6 6 8 8 8 8 8 8 10 10 10 10 10 10 10

6/10-55 6/25-85 8/10-65 8/20-80 8/45-105 8/50-115 8/55-120 8/80-130 10/10-65 10/15-80 10/20-90 10/30-100 10/50-120 10/60-130 10/70-140

h1 mm

40 55 45 55 55 55 55 45 45 60 60 60 60 60 60

tfix max mm

10 25 10 20 45 50 55 80 10 15 20 30 50 60 70

110

Follows on the next page


through-setting heawy duty anchors

Vorpa VE.A Steel anchors

Non-cracked concrete

Technical data

VE.A INOX A4 (A4 Stainless Steel)

Code

Description

Lt mm

d0 mm

h1 mm

13777 13758 52611 13767 13759 13760 13763 13768 13778 13761 13762 13769

VE.A A4 12/20-80 VE.A A4 12/10-100 VE.A A4 12/20-110 VE.A A4 12/20-120 VE.A A4 12/50-140 VE.A A4 12/80-180 VE.A A4 16/5-100 VE.A A4 16/10-110 VE.A A4 16/35-125 VE.A A4 16/50-150 VE.A A4 16/60-175 VE.A A4 20/30-175

80 100 110 120 140 180 100 110 125 150 175 175

12 12 12 12 12 12 16 16 16 16 16 20

50 80 80 90 80 90 80 85 80 100 100 125

mm mm mm mm mm mm

M6 180 70 90 35 100 7

VE.A Anchor Scr Critical axial spacing Ccr Critical edge distance Smin Minimum axial spacing Cmin Minimum edge distance Minimum structural thickness hmin Through hole in the object to be fixed

M8 190 80 95 40 100 9

tfix max mm

20 10 20 20 50 80 5 10 35 50 60 30

M10 220 100 110 50 100 12

M12 300 120 150 60 150 14

M14 340 150 170 75 180 16

Tinst Nm

Ch

65 65 65 65 65 65 115 115 115 115 115 200

19 19 19 19 19 19 24 24 24 24 24 28

M16 380 170 190 85 180 18

Permissible loads - applications in concrete C20/25 VE.A

daN

M20 440 240 220 105 210 22

Description

13770 13771 13772 13773

VE.A M VE.A M VE.A M VE.A M

6/50 8/50 10/60 12/75

1 daN ≃1 kg 245

420

520

770

850

950

1390

1850 h1

Lt mm

M mm

d0 mm

h1 mm

Tinst Nm

50 50 60 75

M6 M8 M10 M12

8 10 12 16

55 55 65 80

10 20 45 65

VE.A M INOX A2 internal thread (A2 Stainless Steel)

13770 A2 13771 A2 13772 A2 13773 A2

VE.A A2 M VE.A A2 M VE.A A2 M VE.A A2 M

6/50 8/50 10/60 12/75

VE.A M Anchor Scr Critical axial spacing Ccr Critical edge distance Smin Minimum axial spacing Cmin Minimum edge distance Minimum structural thickness hmin Through hole in the object to be fixed

50 50 60 75

M6 M8 M10 M12

mm mm mm mm mm mm

M6/Ø8 180 70 90 35 100 7

8 10 12 16 M8/Ø10 190 80 95 40 100 9

55 55 65 80

M10/Ø12 220 100 110 50 100 12

daN

M

Screw length calculation: Lv = Lt + tfix

10 20 45 65

h1 = Min. hole depth Lt = Anchor length d0 = Hole diameter tinst = Torque M = Internal thread

M12/Ø16 300 120 150 60 150 14

Permissible loads - applications in concrete C20/25 VE.A M

h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner

M24 520 240 290 115 240 26

VE.A M internal thread Code

Screw length calculation: Lv = Lt + tfix

1 daN ≃1 kg 220

340

480

620

- Always respect the installation parameters - In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) - The table shows the permissible loads for tension, shear and combined tension and shear loads.

111


through-setting heawy duty anchors

Vorpa VE.A Steel anchors

Non-cracked concrete

Technical data VE.CE7 diameter 16 extra long steel anchor fixing system for wooden beams on non-cracked concrete Option 7 with A2 stainless steel clip Code

2227 2228 2229 2230 2235 2236 2237

Description

Lt mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Ch

VE.CE 7 16/125-240 VE.CE 7 16/145-260 VE.CE 7 16/165-280 VE.CE 7 16/185-300 VE.CE 7 16/215-330 VE.CE 7 16/245-360 VE.CE 7 16/280-400

240 260 280 300 330 360 400

16 16 16 16 16 16 16

120 120 120 120 120 120 120

125 145 165 185 215 245 280

100 100 100 100 100 100 100

24 24 24 24 24 24 24

h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner

Attention: Steel anchor diameter 16 length over 220mm assembled with washer DIN 9021. Thickness of wooden beams up to 280mm

Installation data Anchor type Installation data VE.CE7 Anchor diameter Anchor length

M16

M16 Lungo

d L

mm mm

16 120-220

16 221-400

hef Tfix d0 h1 df Tinst Scr,N Ccr,N Smin Cmin hmin

mm mm mm mm mm Nm mm mm mm mm mm

75,8 1-245 16 120 18 100 270 135 96 128 200

75,8 280 16 120 18 100 270 135 96 128 200

Nrk,P C20/25

KN

25 1,22 1,41 1,55

25 1,22 1,41 1,55

VRk,S C20/25 MRK,S

KN Nm

39,3 166

13,5 166

Values where the reduction factor γ is included (Design loads) Nrk,P Pull out failure KN VRk,S Shear failure KN MRK,S Bending moment Nm

13,9 31,4 132,8

13,9 10,8 132,8

Recommended loads Pull out failure Shear failure Bending moment

9,9 22,4 75

9,9 7,7 75

Effective anchorage depth Fixture thickness Drill hole diameter Drill hole depth Hole diameter in the fixture Torque moment Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum thickness member Characteristic values Pull out failure non cracked concrete Ψc C30/37 Ψc C40/50 Ψc C50/60 Shear failure Bending moment

N T M

KN KN Nm

112

Screw length calculation: Lv = Lt + tfix


through-setting heawy duty anchors

Vorpa VE Steel anchors

Non-cracked concrete

Products group Suitable for • Non-cracked concrete

Test reports available

To fix • Plants engineering • Heavy structural works • Metal structures • Profiles • Gates • Stairs • Parapets • Machineries • Balustrades

Software Vorpa Calcul Anchor

Examples of applications

Product information Characteristics • High performances through steel anchor composed of steel pin, nut, washer and two stainless steel expansion clips. • When the hexagonal nut is tightened, the tapered bolt is pulled into the expansion clip and expands it against the drill hole wall Benefits • Reduced hole diameter • Suitable for through-setting applications in concrete • Thread diameter and hole diameter are the same • Reinforced anchor’s head to avoid damaging the thread during the installation • Minimum slippage due to powerfull expansion when tightening • Fast setting also thanks to pre-mounted nut and washer

Installation • Through-setting anchor Suggestion for use • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

113


through-setting heawy duty anchors

Vorpa VE Steel anchors

Non-cracked concrete

Installation sequence

Technical data

Code

601 602 603 604 605 599 606 607 608 609 610 611 612 613 614 615 600 616 589 617

Description

Lt mm

L. thread mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Ch

VE 6/5-45 VE 6/15-65 VE 6/40-100 VE 8/5-55 VE 8/10-75 VE 8/25-90 VE 8/50-115 VE 10/10-65 VE 10/20-90 VE 10/40-120 VE 12/5-75 VE 12/15-110 VE 12/25-145 VE 12/80-180 VE 14/15-110 VE 14/25-145 VE 16/10-110 VE 16/25-145 VE 16/55-175 VE 16/100-220

45 65 100 55 75 90 115 65 90 120 75 110 145 180 110 145 110 145 175 220

19 39 74 20 40 55 75 26 42 71 27 45 90 90 45 75 46 78 81 96

6 6 6 8 8 8 8 10 10 10 12 12 12 12 14 14 16 16 16 16

35 45 55 40 60 55 55 45 60 70 60 85 110 90 85 110 85 105 105 105

5 15 40 5 10 25 50 10 20 40 5 15 25 80 15 25 10 25 55 100

10 10 10 20 20 20 20 45 45 45 65 65 65 65 85 85 115 115 115 115

10 10 10 13 13 13 13 17 17 17 19 19 19 19 22 22 24 24 24 24

Installation data

VE Anchor Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness

Scr Ccr Smin Cmin hmin

mm mm mm mm mm

M6 180 70 90 35 100

M8 190 80 95 40 100

M10 220 100 110 50 100

M12 300 120 150 60 150

M14 340 150 170 75 180

Permissible loads - applications in concrete C20/25 VE - - -

daN

M16 380 170 190 85 180

M20 440 240 220 105 210

1 daN ≃1 kg 250

380

520

800

850

1400

1750

Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.

114

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner


heavy duty anchors

Vorpa VE.A L

Safe fastening of reinforcing mats for sprayed concrete

Concrete

Naturale stone

Products group To fix • reinforcing

Suitable for • concrete • natural stone Examples of applications

Product information Installation • Hammer-in anchor

Characteristics • Self expanding hammer-in anchor designed to attach steel reinforcing mats to existing concrete Benefits • Safe and fastening • Thread diameter and hole diameter are the same • The non threaded end is bent to hold the reinforcement mat in place

Suggestion for use • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

Technical data h1

Description

Lt mm

d0 mm

h1 mm

tfix max mm

lb mm

hef mm

91629 VE.A L 8/20-80 91630 VE.A L 8/50-110 91631 VE.A L 8/80-140

80 110 140

8 8 8

65 65 65

20 50 80

32 35 35

55 55 55

Code

Installation sequence h1 Lt d0 tfix

Installation data Permissible loads - applications in concrete C20/25 VE.A L 8

1 daN ≃1 kg Tension 570

Shear 630

115

= Min. hole depth = Anchor length = Hole diameter = Fixture thickness


through-setting heawy duty anchors

Vorpa VSA heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete

Cracked and non-cracked concrete

Products group VSA V with 8.8 hexagonal head

VSA B with stud and nut

VSA S with 10.9 flat countersunk head

Approved for • Cracked concrete C20/25 to C50/60 • Non cracked concrete C20/25 to C50/60 Also suitable for • Concrete C12/15 • Natural stone

Suitable • parapets • steel beams • machine tools • industrial systems • heavy duty metal constructions • structural fixings

FIXING IN SEISMIC Annex E-C1 IN PROGRESS

ETA-19/0885 ETAG 1 Option 1 for cracked concrete

R30-R120 European technical assesment EAD 330232 - 00 - 0601 Cracked and non-cracked concrete seismic fixing - Cat. C1, M8-M12 (in progress)

Software Vorpa Calcul Anchor As it can also be used on concrete with different strength characteristics, as specified in ETA, on compact natural stone and others materials (exception not included in ETA), specific on-site tests by the user are necessary

Examples of applications

116


through-setting heawy duty anchors

Vorpa VSA heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete

Cracked and non-cracked concrete

Product information Characteristics • High performances through steel anchor with central bush and anti-rotation system

Installation • Through-setting anchor Suggestion for use • Choose the most suitable accessory in relation to the application to carry out • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

Benefits • When the hexagon nut or screw is tightened, the cone is pulled into the expansion sleeve and expands tensioning it against the hole wall • Smooth expansion thanks to the three cuts on the expansion body • High tensile loads with standard depth • High shear resistances, applications are possible with minimim centre to centre and edge distance • The red ring collar prevents the anchor turning in the hole on installation • Regular grip on the base material thanks to the expansion shell • Fixing in seismic C1 in progress • Approved for cracked and non-cracked concrete

Installation sequence

Technical data

VSA V with 8.8 hexagonal head screw

Code

Description

Lt mm

for screw d x Lv mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Ch

10880 10881 10882 10883 10884 10885 10886 10887 10888 10889 10890 * 10891 *

VSA V 12/10-80 VSA V 12/20-90 VSA V 12/50-120 VSA V 15/10-90 VSA V 15/20-100 VSA V 15/50-130 VSA V 18/10-110 VSA V 18/25-125 VSA V 18/50-150 VSA V 18/100-200 VSA V 24/25-140 VSA V 24/50-165

80 90 120 90 100 130 110 125 150 200 140 165

M8x80 M8x90 M8x120 M10x90 M10x100 M10x130 M12x120 M12x130 M12x160 M12x200 M16x 140 M16x 170

12 12 12 15 15 15 18 18 18 18 24 24

85 85 85 95 95 95 120 120 120 120 130 130

10 20 50 10 20 50 10 25 50 100 25 50

25 25 25 50 50 50 80 80 80 80 150 150

13 13 13 17 17 17 19 19 19 19 24 24

* Not included in C1 fixing in seismic

117

h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness Tinst = Torque Ch = Spanner


through-setting heawy duty anchors

Vorpa VSA heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete

Cracked and non-cracked concrete

dati tecnici

VSA B with stud and nut

Code

Description

Lt mm

for screws d x Lb mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Ch

10900 10901 10902 10903 10904 10905 10906 10907 10908 10909 10910 * 10911 *

VSA B 12/10-80 VSA B 12/20-90 VSA B 12/50-120 VSA B 15/10-90 VSA B 15/20-100 VSA B 15/50-130 VSA B 18/10-110 VSA B 18/25-125 VSA B 18/50-150 VSA B 18/100-200 VSA B 24/25-140 VSA B 24/50-165

80 90 120 90 100 130 110 125 150 200 140 165

M8x92 M8x102 M8x132 M10x105 M10x115 M10x145 M12x135 M12x150 M12x180 M12x220 M16x165 M16x190

12 12 12 15 15 15 18 18 18 18 24 24

85 85 85 95 95 95 120 120 120 120 130 130

10 20 50 10 20 50 10 25 50 100 25 50

25 25 25 50 50 50 80 80 80 80 150 150

13 13 13 17 17 17 19 19 19 19 24 24

h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness Tinst = Torque Ch = Spanner Lb = Stud length

* Not included in C1 fixing in seismic

VSA S with 10.9 flat countersunk head

Code

Description

Lt mm

for screws d x Lv mm

d0 mm

h1 mm

Tfix max mm

Tinst Nm

10920 10921 10922 10923 10924 10925 10926 10927 10928

VSA S 12/16-85 VSA S 12/26-95 VSA S 12/56-125 VSA S 15/15-95 VSA S 15/25-105 VSA S 15/55-135 VSA S 18/18-120 VSA S 18/33-135 VSA S 18/58-160

85 95 125 95 105 135 120 135 160

M8x80 M8x90 M8x130 M10x100 M10x110 M10x140 M12x120 M12x140 M12x170

12 12 15 15 15 15 18 18 18

85 85 95 95 95 95 120 120 120

16 26 56 15 25 55 18 33 58

25 25 50 50 50 50 80 80 80

118

h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness Tinst = Torque Ch = Spanner Lb = Stud length


through-setting heawy duty anchors

Vorpa VSA heavy duty safety anchor for cracked concrete and seismic zone Steel anchor with ETA option 1 cracked concrete

Cracked and non-cracked concrete

Installation data Anchor type Installation data Anchor diameter Anchor length Effective anchorage depth Fixture thickness Drill hole diameter Drill hole depth Hole diameter in the fixture Torque moment

VSA-V/VSA-B M8 VSA-V/VSA-B M10 VSA-V/VSA-B M12 VSA-V/VSA-BM16 d L hef Tfix d0 h1 df Tinst

mm mm mm mm mm mm mm Nm

12 80-90-110 59 10-20-50 12 85 14 25

15 90-100-130 67 10-20-50 15 95 17 50

18 110-125-150-200 88 10-25-50-100 18 120 20 80

24 140-165 99 25-50 24 130 26 150

Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum thickness member

Scr,N Ccr,N Smin Cmin hmin

mm mm mm mm mm

250 200 120 80 125

290 220 140 90 13

390 260 180 110 190

420 280 240 130 220

VSA-S M8

VSA-S M10

VSA-S M12

Anchor type Installation data Anchor diameter Anchor length Effective anchorage depth Fixture thickness Drill hole diameter Drill hole depth Hole diameter in the fixture Torque moment

d L hef Tfix d0 h1 df Tinst

mm mm mm mm mm mm mm Nm

12 86-96-126 59 16-26-56 12 85 14 25

15 95-105-135 67 15-25-55 15 95 17 50

18 120-135-160 88 18-33-58 18 120 20 80

Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum thickness member

Scr,N Ccr,N Smin Cmin hmin

mm mm mm mm mm

250 200 120 80 125

290 220 140 90 13

390 260 180 110 190

Ø12

Ø15

Ø18

Ø24

Characteristic values Pull out failure Non-cracked concrete Cracked concrete C30/37 C40/50 C50/60

Nrk,P C20/25 Nrk,P C20/25 Ψ 30/37 Ψ 40/50 Ψ 50/60

KN KN -

12 7 1,22 1,41 1,55

16 10 1,22 1,41 1,55

25 18 1,22 1,41 1,55

40 28 1,22 1,41 1,55

VRk,S MRK,S

KN Nm

16,8 30

25 60

33,7 105

62,8 266

Values where the reduction factor is included Pull out failure Nrk,P Non-cracked concrete Nrk,P Cracked concrete Vrk Shear failure Mrk Bending moment

KN KN KN Nm

10 5,8 13,4 24

13,3 8,3 20 48

20,8 15 26,9 84

33,3 23,3 50,2 212,8

Design load with safety factor included Pull out failure Non-cracked concrete Cracked concrete Shear failure Bending moment

KN KN KN Nm

7,1 4,1 9,5 17,1

9,5 5,9 14,2 34,2

14,8 10,7 19,2 60

23,7 16,6 35,8 152

Shear failure Bending moment

N N V M

119


through-setting heawy duty anchors

Vorpa VSP

Steel anchors with ETA option 7 for non-cracked concrete

Non-cracked concrete

Products group VSP V [*] with 8.8 hexagonal head screw

Suitable to fix • Parapets • Steel beams • Machine tools • Industrial systems • Heavy duty metal constructions

Approved for • Non-cracked concrete Also suitable for • Natural stone • Concrete C12/C15

VSP B [*] with stud and nut

VSP S with 10.9 flat countersunk head

[*] VSP D with blind nut

European Technical Approval Option 7 for non-cracked concrete

As it can also be used on concrete with different strength characteristics, as specified in ETA, on compact natural stone and others materials (exception not included in ETA), specific on-site tests by the user are necessary

Examples of applications

120

Software Vorpa Calcul Anchor


through-setting heawy duty anchors

Vorpa VSP

Steel anchors with ETA option 7 for non-cracked concrete

Non-cracked concrete

Product information Characteristics • High performances through steel anchor with central bush and anti-rotation system • When the hexagon nut or screw is tightened, the cone is pulled into the expansion sleeve and expands tensioning it against the hole wall. Benefits • Smooth expansion thanks to the three cuts on the expansion body • High tensile loads with standard depth • High shear resistances, applications are possible with minimin centre to centre and edge distance • The red ring collar prevents the anchor turning in the hole on installation • Regular grip on the base material thanks to the expansion shell

Installation • Through-setting anchor Suggestion for use • Choose the most suitable accessory in relation to the application to carry out • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

Installation sequence

Technical data

VSP V with 8.8 hexagonal head screw

Code

8860 8861 8862 8864 8865 8866 8868 8869 8870 8872 8873 8874 8875 8877 8878

Description

Lt mm

for screws d x Lv mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Ch

VSP V 10/10-70 VSP V 10/20-80 VSP V 10/50-110 VSP V 12/10-80 VSP V 12/20-90 VSP V 12/50-120 VSP V 15/10-90 VSP V 15/20-100 VSP V 15/50-130 VSP V 18/10-110 VSP V 18/25-125 VSP V 18/50-150 VSP V 18/100-200 VSP V 24/25-140 VSP V 24/50-165

70 80 110 80 90 120 90 100 130 110 125 150 200 140 165

M6x70 M6x80 M6x110 M8x80 M8x90 M8x120 M10x90 M10x100 M10x130 M12x120 M12x130 M12x160 M12x200 M16x 140 M16x 170

10 10 10 12 12 12 15 15 15 18 18 18 18 24 24

75 75 75 85 85 85 95 95 95 120 120 120 120 130 130

10 20 50 10 20 50 10 20 50 10 25 50 100 25 50

10 10 10 25 25 25 50 50 50 80 80 80 80 150 150

10 10 10 13 13 13 17 17 17 19 19 19 19 24 24

121

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length


through-setting heawy duty anchors

Vorpa VSP

Steel anchors with ETA option 7 for non-cracked concrete

Non-cracked concrete

Technical data

VSP B with stud and nut

Code

9860 9861 9862 9864 9865 9866 9868 9869 9870 9872 9873 9874 9875 9877 9878

Description

Lt mm

for screws d x Lb mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Ch

VSP B 10/10-70 VSP B 10/20-80 VSP B 10/50-110 VSP B 12/10-80 VSP B 12/20-90 VSP B 12/50-120 VSP B 15/10-90 VSP B 15/20-100 VSP B 15/50-130 VSP B 18/10-110 VSP B 18/25-125 VSP B 18/50-150 VSP B 18/100-200 VSP B 24/25-140 VSP B 24/50-165

70 80 110 80 90 120 90 100 130 110 125 150 200 140 165

M6x80 M6x90 M6x120 M8x92 M8x102 M8x132 M10x105 M10x115 M10x145 M12x135 M12x150 M12x180 M12x220 M16x165 M16x190

10 10 10 12 12 12 15 15 15 18 18 18 18 24 24

75 75 75 85 85 85 95 95 95 120 120 120 120 130 130

10 20 50 10 20 50 10 20 50 10 25 50 100 25 50

10 10 10 25 25 25 50 50 50 80 80 80 80 150 150

10 10 10 13 13 13 17 17 17 19 19 19 19 24 24

VSP S with 10.9 flat countersunk head

Code

Description

Lt mm

for screws d x Lv mm

d0 mm

h1 mm

Tfix max mm

Tinst Nm

Ch

11875 11876 11877 11878

VSP S 12/10-80 VSP S 12/50-120 VSP S 15/10-90 VSP S 15/50-130

80 120 90 130

M8x90 M8x130 M10x100 M10x140

12 12 15 15

85 85 95 95

10 50 10 50

25 25 50 50

13 13 17 17

VSP D with stud and nut

Code

Description

Lt mm

for screws d x Lb mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Ch

10860 10861 10862 10864 10865 10866 10868 10869 10870 10872 10873 10874 10875 10877 10878

VSP D 10/10-70 VSP D 10/20-80 VSP D 10/50-110 VSP D 12/10-80 VSP D 12/20-90 VSP D 12/50-120 VSP D 15/10-90 VSP D 15/20-100 VSP D 15/50-130 VSP D 18/10-110 VSP D 18/25-125 VSP D 18/50-150 VSP D 18/100-200 VSP D 24/25-140 VSP D 24/50-165

70 80 110 80 90 120 90 100 130 110 125 150 200 140 165

M6x80 M6x90 M6x120 M8x92 M8x102 M8x132 M10x105 M10x115 M10x145 M12x135 M12x150 M12x180 M12x220 M16x165 M16x190

10 10 10 12 12 12 15 15 15 18 18 18 18 24 24

75 75 75 85 85 85 95 95 95 120 120 120 120 130 130

10 20 50 10 20 50 10 20 50 10 25 50 100 25 50

10 10 10 25 25 25 50 50 50 80 80 80 80 130 130

10 10 10 13 13 13 17 17 17 19 19 19 19 24 24

122

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length


through-setting heawy duty anchors

Vorpa VSP

Steel anchors with ETA option 7 for non-cracked concrete

Non-cracked concrete

Installation data VSP10 M6

VSP12 M8

VSP15 M10

VSP18 M12

VSP24 M16

mm mm mm mm mm mm mm Nm

10 70-80-110 49 10-20-50 10 75 12 10

12 80-90-110 59 10-20-50 12 85 14 25

15 90-100-130 67 10-20-50 15 95 17 50

18 110-125-150-200 88 10-25-50-100 18 120 20 80

24 140-165 99 25-50 24 130 26 150

Scr,N Ccr,N Smin Cmin hmin

mm mm mm mm mm

210 140 100 70 100

250 200 120 80 125

290 220 140 90 13

390 260 180 110 190

420 280 240 130 220

Nrk,P C20/25

KN

9 1,22 1,41 1,55

12 1,22 1,41 1,55

16 1,22 1,41 1,55

25 1,22 1,41 1,55

40 1,22 1,41 1,55

VRk,S C20/25 MRK,S

KN Nm

8 12

14,6 30

23,2 60

33,7 105

62,8 266

Values where the reduction factor γ is included (Design loads) Nrk,P Pull out failure KN VRk,S Shear failure KN MRK,S Bending moment Nm

6 6,4 9,6

6,7 11,7 24

8,9 18,6 48

16,7 27 84

22,2 50,2 212,8

Recommended loads Pull out failure Shear failure Bending moment

4,2 4,6 6,8

4,8 8,3 17

6,3 13,2 34,3

11,9 19,3 60

15,8 35,8 152

Anchor type Installation data Anchor diameter Anchor length Effective anchorage depth Fixture thickness Drill hole diameter Drill hole depth Hole diameter in the fixture Torque moment

d L hef Tfix d0 h1 df Tinst

Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum thickness member Characteristic values Pull out failure Ψc C30 Ψc C40 Ψc C50 Shear failure Bending moment

KN KN Nm

123


through-setting heawy duty anchors

Vorpa VSX Steel anchors

Concrete

Products group VSX with blind nut

Suitable for • Concrete

VSX INOX A2 with blind nut

Suitable to fix • Parapets • Steel beams • Machine tools • Industrial systems • Heavy duty metal constructions • Industrial signals

Software Vorpa Calcul Anchor

Examples of applications

Product information Characteristics • High performances through steel anchor with central bush and anti-rotation system Benefits • Reduced hole diameter granting a better capacity • Smooth expansion thanks to the three cuts on the expansion body • The red collar prevents the anchor turning in the hole on installation

Installation • Through-setting anchor Suggestion for use • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

Installation sequence

124


through-setting heawy duty anchors

Vorpa VSX Steel anchors

Concrete

Technical data

VSX with blind nut

Code

959 958 960 961 962 963 964 965 967 966

Description

Lt mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Ch

VSX 8/15-70 VSX 8/30-85 VSX 10/15-85 VSX 10/50-120 VSX 12/15-100 VSX 12/50-135 VSX 14/20-115 VSX 14/50-145 VSX 16/20-130 VSX 16/40-150

65 80 75 110 85 120 100 130 110 130

8 8 10 10 12 12 14 14 16 16

55 55 65 65 75 75 85 85 95 95

15 30 15 50 15 50 20 50 20 40

6 6 10 10 25 25 50 50 85 85

13 13 17 17 19 19 22 22 24 24

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length

VSX inox A2 with blind nut (A2 Stainless Steel) Code

3959 3958 3960 3961 3962 3963

Description

Lt mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Ch

VSX A2 8/15-70 VSX A2 8/30-85 VSX A2 10/15-85 VSX A2 10/50-120 VSX A2 12/15-100 VSX A2 12/50-135

65 80 75 110 85 120

8 8 10 10 12 12

55 55 65 65 75 75

15 30 15 50 15 50

6 6 10 10 25 25

13 13 17 17 19 19

Installation data

VSX Anchor Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness

Scr Ccr Smin Cmin hmin

mm mm mm mm mm

VSX 8/M5 180 90 90 50 150

VSX 10/M6 220 110 130 70 150

VSX 12/M8 VSX 10/M10 VSX 16/M12 280 400 450 140 170 200 170 230 270 90 110 140 200 200 250

Permissible loads - applications in concrete C20/25 VSX - VSX A2 - - -

daN

1 daN ≃1 kg 250

350

470

600

700

Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.

125


through-setting heawy duty anchors

Vorpa CSB CE+SEISMIC Steel safety screw for cracked concrete and seismic zone Steel screw fixings with Eta Option 1 for cracked and non cracked concrete

Cracked and non cracked concrete

Products group CSB CE [*] with hexagonal head

Approved for • Cracked and non cracked concrete Ø8-Ø16 • Seismic applications TR045 categ. C1-C2: Ø12 - Ø16, categ. C1: Ø10 • Anchorage under fire exposure in standard TR 020 R30-R120

CSB with mushroom head Torx recess

CSB E CE [*] with hexagonal stud and nut

Also suitable for • Natural stone • Concrete C12/C15

CSB S CE [*] with countersunk head Torx recess

To fix • Parapets • Steel beams • Machine tools • Industrial systems • Heavy duty metal constructions • Structural fixings • Profiles • Pipes • Plants engineering • Railings • Gates • Window and door frames

As it can also be used on concrete with different strength characteristics, as specified in ETA, on compact natural stone and others materials (exception not included in ETA), specific on-site tests by the user are necessary

European Technical Assesment EAD 330323-00-0601 ANNEX E Option 1 - Cracked and non cracked concrete Seismic fixings - category C1-C2 annex E - TR045

R30-R120

Annex E -

C1-C2

Examples of applications

Product information Characteristics • Steel screw fixing with special dual lead thread design • When the concrete screw is screwed into the hole, the thread taps into the concrete and creates a positive fit anchorage • Certified ETA-CE option1 and performance category C1-C2 under seismic action

Benefits • Suitable for use in compression resistant natural stone (without approval) • Approved under the building regulations with a new European Technical Assessment (Option 1) • Approved for use in cracked and non-cracked concrete

Benefits • Reduced hole diameter • Vibrations resistance, easy to identify by the screw’s head • Ideal for permanent and removable fixing both inside and outside • Virtually expansion-free operation allows cost-efficient fixing with small axial spacing and edge distances. • Fire tested in compliance with DIN 4102-2. Fire resistance ratings R30–R120 • Approved for use under seismic loading, performance categories c1-c2

Installation • Through-setting anchor Suggestion for use • Choose the most suitable accessory in relation the application to carry out • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

126


through-setting heawy duty anchors

Vorpa CSB CE+SEISMIC Steel safety screw for cracked concrete and seismic zone Steel screw fixings with Eta Option 1 for cracked and non cracked concrete

Cracked and non cracked concrete

Installation sequence

Technical data

CSB CE with hexagonal head

Code

Description

93672 93673 93674 93676 93677 93678 93679 93680 93681 93682 93683 93684 93685 93686 93687 93688 93689 93690 93691

CSB CE 8x80 CSB CE 8x100 CSB CE 8x120 CSB CE 10x80 CSB CE 10x100 CSB CE 10x120 CSB CE 10x140 CSB CE 10x160 CSB CE 12x90 CSB CE 12x110 CSB CE 12x130 CSB CE 12x150 CSB CE 12x190 CSB CE 12x210 CSB CE 12x250 CSB CE 12x290 CSB CE 16x130 CSB CE 16x150 CSB CE 16x180

dv x Lv mm

tfix mm

8 x 80 8 x 100 8 x 120 10 x 80 10 x 100 10 x 120 10 x 140 10 x 160 12 x 90 12 x 110 12 x 130 12 x 150 12 x 190 12 x 210 12 x 250 12 x 290 12 x 130 16 x 150 16 x 180

20 40 60 10 30 50 70 90 10 30 50 70 110 130 170 210 20 40 70

d0 mm

6 6 6 8 8 8 8 8 10 10 10 10 10 10 10 10 14 14 14

h1 mm

hmin mm

hnom mm

hef mm

tinst Nm

Ch

Cmin mm

Smin mm

75 75 75 85 85 85 85 85 100 100 100 100 100 100 100 100 140 140 140

100 100 100 110 110 110 110 110 130 130 130 130 130 130 130 130 170 170 170

60 60 60 70 70 70 70 70 80 80 80 80 80 80 80 80 110 110 110

48 48 48 56 56 56 56 56 64 64 64 64 64 64 64 64 85 85 85

20 20 20 50 50 50 50 50 80 80 80 80 80 80 80 80 160 160 160

10 10 10 13 13 13 13 13 15 15 15 15 15 15 15 15 21 21 21

45 45 45 50 50 50 50 50 60 60 60 60 60 60 60 60 80 80 80

45 45 45 50 50 50 50 50 60 60 60 60 60 60 60 60 80 80 80

h1 = Minimum depth of drill hole Lv = Screw length d0 = Drill hole diameter dv = Screw diameter df = Diameter of clearance hole in the fixture tfix = Maximum thickness of fixture tinst = Required torque moment Ch = Spanner hmin = Minimum thickness of concrete member hnom = Overall anchor embedment depth hef = Effective anchorage depth T = 6 lobe recess Cmin = Minimum allowable edge distance Smin = Minimum allowable spacing Ccr = Edge distance for ensuring the transmission of the characteristic resistance of a single anchor Scr = Spacing for ensuring the transmission of the characteristic resistance of a single anchor

CSB with mushroom head Torx recess

Code

Description

3381 3383 4379 93735 93736 93738 93739

CSB B 8x60 CSB B 8x80 CSB B 8x100 CSB B 10x60 CSB B 10x80 CSB B 10x100 CSB B 10x120

dv x Lv mm

8 x 60 8 x 80 8 x 100 10 x 60 10 x 80 10 x 100 10 x 120

tfix mm

10 20 40 10 10 30 50

d0 mm

6 6 6 8 8 8 8

h1 mm

65 75 75 70 90 90 90

hmin mm

hnom mm

hef mm

df mm

100 110 110 100 130 130 130

50 60 60 50 70 70 70

45 55 55 45 65 65 65

9 9 9 12 12 12 12

tinst Nm

20 20 20 50 50 50 50

T

Cmin mm

Smin mm

Ccr mm

Scr Characteristic loads (kN) mm Pull out Shear

T30 T30 T30 T40 T40 T40 T40

45 45 45 55 55 55 55

45 45 45 55 55 55 55

75 90 90 75 105 105 105

150 180 180 150 210 210 210

7,6 11,2 11,2 9,2 15,6 15,6 15,6

14,1 14,1 14,1 23,4 23,4 23,4 23,4

Pull-out and shear showed in the table are CHARACTERISTIC LOADS from tests run on non-cracked concrete C20/25 without edge and spacing effect (Pull-out and shear loads are in kN: 1kN = 100kg).

127


through-setting heawy duty anchors

Vorpa CSB CE+SEISMIC Steel safety screw for cracked concrete and seismic zone Steel screw fixings with Eta Option 1 for cracked and non cracked concrete

Cracked and non cracked concrete

Technical data

CSB CE with hexagonal stud and nut

Code

Description

93710 93711 93713 93725 93726 93727 93728

CSB E CE 8x90 CSB E CE 8x120 CSB E CE 10x105 CSB E CE 10x125 CSB E CE 10x195 CSB E CE 12x118 CSB E CE 12x138

dv x Lv mm

tfix mm

8 x 90 8 x 120 10 x 105 10 x 125 10 x 195 12 x 118 12 x 138

10 40 10 30 100 10 30

d0 mm

6 6 8 8 8 10 10

h1 mm

hmin mm

hnom mm

hef mm

75 75 90 90 90 100 100

100 100 110 110 110 130 130

60 60 70 70 70 80 80

48 48 56 56 56 64 64

tinst Nm

20 20 50 50 50 80 80

Ch

Cmin mm

Smin mm

5 5 7 7 7 8 8

45 45 50 50 50 60 60

45 45 50 50 50 60 60

Ch

Cmin mm

Smin mm

T30 T30 T30 T40 T40 T40 T50 T50

45 45 45 50 50 50 60 60

45 45 45 50 50 50 60 60

CSB CE with countersunk head Torx recess

dv x Lv mm

Code

Description

93700 93701 93702 93703 93704 93705 93706 93707

CSB S CE 8x70 CSB S CE 8x100 CSB S CE 8x140 CSB S CE 10x80 CSB S CE 10x100 CSB S CE 10x160 CSB S CE 12x100 CSB S CE 12x120

8 x 70 8 x 100 8 x 140 10 x 80 10 x 100 10 x 160 12 x 100 12 x 120

tfix mm

d0 mm

10 40 80 10 30 90 20 40

6 6 6 8 8 8 10 10

h1 mm

hmin mm

hnom mm

hef mm

75 75 75 90 90 90 100 100

100 100 100 110 110 110 130 130

60 60 60 70 70 70 80 80

48 48 48 56 56 56 64 64

tinst Nm

20 20 20 50 50 50 80 80

Installation data Characteristic Values CSB - CSB E - CSBS Pull out Pull out Pull out Pull out Ψc C30/37 Ψc C40/50 Ψc C50/60 Shear failure Shear failure Shear failure Bending moment

NRKP NRKP NRKP, p, eq NRKP, p, eq

C20/25 (non-cracked) C20/25 (cracked) Cat. C1 Cat. C2

[kN] [kN] [kN] [kN]

Ø8

Ø10

Ø12

Ø16

16 4 -

20 7,5 6 -

25 9 6,3 2,7

40 16 16 7,2

1,22 1,41 1,55 VRKS VRKS, s, eq VRKS, s, eq MRKS

[kN] [kN] [kN] [kN]

9,4 19

20,1 12,1 44

32,4 19,1 17,7 83

56,9 39,8 39,8 216

Values with reduction factor (design loads) NRKP Pull out C20/25 (non-cracked) NRKP Pull out C20/25 (cracked) NRKP, p, eq Cat. C1 Pull out NRKP, p, eq Cat. C2 Pull out VRKS Shear failure MRKS Bending moment

[kN] [kN] [kN] [kN] [kN] [kN]

11,4 2,8 6,2 12,6

16,6 6,2 5 13,4 29,3

17,8 6,4 4,5 1,9 21,6 55,3

28,5 11,4 11,4 5,1 37,9 144

Recommended loads Pull out Pull out Pull out Pull out Shear failure Bending moment

[kN] [kN] [kN] [kN] [kN] [kN]

8,1 2 4,4 9

11,8 4,4 3,5 9,5 20

12,7 4,5 3,2 1,3 15,4 39,5

20,3 8,1 8,1 3,6 27 102

N N N N V M

Cat. C1 Cat. C2

(non-cracked) (cracked) Cat. C1 Cat. C2

128


pre-setting heavy duty anchors

Vorpa VA Steel anchors

Non-cracked concrete

Products group ETA version approved for • Non-cracked concrete C20/25 - C50/60 - M6-M16 • Multiple use for non structural applications on non-cracked concrete C20/25 - C50/60 - M6-M16

VA CE [*] with internal thread

VA with internal thread VA INOX A4 (A4 stainless steel) internal thread

To fix • Railings • Plants engineering • Beams • Sections • Ventilation systems and ceiling heating systems • Ceiling lighting

All versions • Non cracked concrete C20/25 C50/60 • Natural stone

VA F CE lipped type

[*]

VA F lipped type European Technical Approval Option 7 for non-cracked concrete

PERNO VA Impacting tool

Multiple use in non-cracked concrete for non structural applications

As it can also be used on concrete with different strength characteristics, as specified in ETA, on compact natural stone and others materials (exception not included in ETA), specific on-site tests by the user are necessary

Examples of applications

Product information Characteristics • Steel anchor with internal thread and internal expansion cone to be used with bolts or threaded bars. • When the cone is driven in with the apposite impacting tool, the anchor sleeve is spread and thus expands against the hole wall. Benefits • Easy application and quick and safe installation thanks to the proper impacting tool • The collar of the lipped type avoid the slipping of the anchor inside the hole • Suitable for bars and accessories with metrical thread • Possibility of inserting the anchor through the object to be fixed • Low anchorage depth reduces drilling time and thus cost- efficient installation

Benefits • Surface-flush anchor allows the attached items to be removed and refitted several times. Installation • Pre-setting anchor • Through-setting only in the version VA Suggestion for use • Choose the most suitable type in relation to the application to carry out • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

129


pre-setting heavy duty anchors

Vorpa VA Steel anchors

Non-cracked concrete

Installation sequence

Technical data VA.CE

Code

Description

99591 99594 99592 99593

VA.CE 8x30 VA.CE 8x40 VA.CE 10x40 VA.CE 12x50

Lt mm

d0 mm

h1 mm

for screws Ø mm

internal thread L mm

30 40 40 50

10 10 12 15

30 40 40 50

M8 M8 M10 M12

13 20 15 18 Screw length calculation: Lv = Lt + tfix

VA. F CE

Code

Description

98590 98591 98592 98593 98594

VA F CE 8x30 VA F CE 8x40 VA F CE 10x30 VA F CE 10x40 VA F CE 12x50

Lt mm

d0 mm

h1 mm

for screws Ø mm

internal thread L mm

30 40 30 40 50

8 8 10 10 12

30 40 30 40 50

M8 M8 M10 M10 M12

13 20 12 15 18

Installation data Anchor type Installation data VA CE / VA F CE Anchor diameter Anchor length Effective anchorage depth Drill hole diameter Drill hole depth Hole diameter in the fixture Torque moment Critical axial spacing Critical edge distance Minimum thickness member

M8

M10

M12

Tinst ≤

mm mm mm mm mm mm Nm

10 30 30 10 30 9 8

12 40 40 12 40 12 15

15 50 50 15 50 14 35

Scr,N Ccr,N hmin

mm mm mm

90 45 100

120 60 120

150 75 130

d L hef d0 h1 df

Characteristic values application in concrete non-cracked C20/25 11,3/13,5 Pull out failure Nrk,P C20/25 KN 1,22 Ψc C30/37 1,41 Ψc C40/50 1,55 Ψc C50/60

16,9 1,22 1,41 1,55

1 daN ≃1 kg 24,1 1,22 1,41 1,55

Design loads VA CE / VA F CE Pull out failure

N

KN

3,3/3,6

5,1

1 daN ≃1 kg 7,1

Recommended loads VA CE / VA F CE Pull out failure N

KN

2,3/2,5

3,6

1 daN ≃1 kg 5

130

h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner


pre-setting heavy duty anchors

Vorpa VA Steel anchors

Non-cracked concrete

Technical data

VA

Code

590 591 592 593 594 595

7590 7591 7592 7593 7594 7595

VA A4

Description

Lt mm

internal thread L mm

for screws Ø mm

d0 mm

VA 6 VA 8 VA 10 VA 12 VA 16 VA 20

25 30 40 50 65 80

12 13 15 18 23 34

M6 M8 M10 M12 M16 M20

8 10 12 15 20 25

30 35 45 55 70 85

4 8 15 35 60 120

VA A4 VA A4 VA A4 VA A4 VA A4 VA A4

25 30 40 50 65 80

12 13 15 18 23 34

M6 M8 M10 M12 M16 M20

8 10 12 15 20 25

30 35 45 55 70 85

4 8 15 35 60 120

Lt mm

internal thread L mm

for screws Ø mm

d0 mm

25 30 30 40 50 50 65 80

12 13 15 25 18 18 23 34

M6 M8 M10 M10 M12 M12 M16 M20

8 10 12 12 15 16 20 25

6 8 10 12 16 20

h1 mm

Tinst Nm

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner

VA F

Code

Description

8590 8591 8592A 8592B 8593 8592 8594 8595

VA F VA F VA F VA F VA F VA F VA F VA F

Code

Description

295 296 298 299 300 1303

6 8 10/30 10/40 12Ø15 12Ø16 16 20

PERNO VA PERNO VA PERNO VA PERNO VA PERNO VA PERNO VA

h1 mm

Tinst Nm

30 35 35 45 55 55 70 85

4 8 15 15 35 35 60 120

for thread VA mm

6 8 10 12 16 20

M6 M8 M10 M12 M16 M20

Scr Ccr hmin

mm mm mm

M6 220 105 170

M8 260 130 170

M10 340 170 220

M12 420 210 220

Permissible loads - applications in concrete C20/25 VA - VA A4 - VA F - - -

N

daN

M16 530 265 245

M20 670 340 330

1 daN ≃1 kg 85

h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner

Impacting tool for VA anchors

Installation data VA Anchor Critical axial spacing Critical edge distance Minimum structural thickness

Screw length calculation: Lv = Lt + tfix

160

400

600

790

1400

Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.

131


pre-setting heavy duty anchors

Vorpa TOP

Steel anchors with ETA option 7 (CE marking) for non-cracked concrete

Non-cracked concrete

Natural stone

Solid brick

Products group TOP [*] no accessories

TOP BU [*] with 8.8 hexagonal head screw

TOP BP [*] through-setting with 8.8 hexagonal head screw and spacer

To fix • Steel structures • Windows and door frames • Railings and balustrades • Gates All versions • Façades • Natural stone • Machineries • Solid brick • Non cracked concrete C12/15 • Iron bars C50/60 ETA version approved for • Non-cracked concrete C20/25 - C50/60 - M6-M16

[*] European Technical Approval Option 7 for non-cracked concrete

TOP BD with stud

TOP OS with eyebolt

TOP OP with eyebolt and spacer

TOP GS with hook-bolt

Option 7 for non-cracked concrete

Software Vorpa Calcul Anchor

As it can also be used on concrete with different strength characteristics, as specified in ETA, on compact natural stone and others materials (exception not included in ETA), specific on-site tests by the user are necessary Examples of applications

TOP TS through-setting with 10.9 countersunk head screw TOP DC through-setting with blind nut TOP INOX A2 TOP INOX A4 [*] no accessories TOP INOX A2 BU TOP INOX A4 BU [*] with hexagonal head screw TOP OS INOX A2 with eyebolt TOP GS INOX A2 with hook-bolt TOP INOX A2 BD TOP INOX A4 BD with threaded stud

TOP BD PROL. A2 with threaded stud

132


pre-setting heavy duty anchors

Vorpa TOP

Steel anchors with ETA option 7 (CE marking) for non-cracked concrete

Non-cracked concrete

Natural stone

Solid brick

Product information Characteristics • Torque controlled expansion anchor made of galvanized steel or stainless steel composed of anti-rotation cold formed body, expansion conical nut and accessory. • When the bolt or hexagon nut is tightened, the cone is pulled into the expansion sleeve and expands it against the hole wall.

Benefits • Three-part expansion sleeve allows even load distribution and small edge and axial spacing. Installation • Pre-setting anchor • Through-setting only in the version TOP BP and TOP TS

Benefits • Wide range of accessories • Anti-rotation during the installation procedure • Suitable for all bolts or studs with metric thread • Fixing can be casily driven in, therefore less installation effort • Surface-flush fixing allows the mounted item to be removed and refitted several times • Anchor version with internal thread for high flexibility by using threaded rods or screws of different lengths and type

Suggestion for use • Choose the most suitable accessory in relation to the application to carry out • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

Installation sequence

Pre-setting anchor TOP

Through-setting anchor TOP

Technical data TOP no accessories

Code

710 711 712 713

Description

Lt mm

for screws Ø mm

d0 mm

h1 mm

TOP 6 TOP 8 TOP 10 TOP 12

45 51 60 75

M6 M8 M10 M12

10 12 14 18

55 60 70 85

TOP BU with 8.8 hexagonal head screw

Code

720 721 722 723

Description

Lt mm

for screws d x Lv mm

d0 mm

h1 mm

Tfix max mm

Tinst Nm

Ch

TOP 6 BU TOP 8 BU TOP 10 BU TOP 12 BU

45 51 60 75

M6x55 M8x65 M10x80 M12x100

10 12 14 18

55 60 70 85

10 14 20 25

10 25 40 75

10 13 17 19

133

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length


pre-setting heavy duty anchors

Vorpa TOP

Steel anchors with ETA option 7 (CE marking) for non-cracked concrete

Non-cracked concrete

Technical data TOP BP through-setting with 8.8 hexagonal head screew and spacer Code

2720 2721 2722 2723

Description

Lt mm

for screws d x Lv mm

d0 mm

h1 mm

Tfix max mm

Tinst Nm

Ch

TOP 6 BP TOP 8 BP TOP 10 BP TOP 12 BP

45 51 60 75

M6x80 M8x90 M10x100 M12x120

10 12 14 18

55 60 70 85

30 35 38 43

10 25 40 75

10 13 17 19

TOP BD with stud

Code

705 706 707 708

Description

Lt mm

for screws d x Lb mm

d0 mm

h1 mm

Tfix max mm

Tinst Nm

Ch

TOP 6 BD 57 TOP 8 BD 75 TOP 10 BD 90 TOP 12 BD 110

45 51 60 75

M6x57 M8x75 M10x90 M12x110

10 12 14 18

55 60 70 85

10 10 20 25

6 15 30 50

10 13 17 19

TOP OS with eyebolt

Code

795 796 797 798

Description

Lt mm

for screws d x L0 mm

d0 mm

h1 mm

Tinst Nm

Ø

TOP 6 OS TOP 8 OS TOP 10 OS TOP 12 OS

45 51 60 75

M6x55 M8x60 M10x73 M12x90

10 12 14 18

55 60 70 85

5 12 20 35

10±0,5 11,8±0,5 14,5±0,5 17±0,5

TOP OP through-setting with spacer and eyebolt

Code

Description

2572 TOP 10 OP

Lt mm

eyebolt d x L0 mm

d0 mm

h1 mm

Tinst Nm

Ø

60

M10x100

14

90

20

14,5

TOP GS with hook-bolt

Code

775 776 777 778

Description

Lt mm

hook bolt d x Lg mm

d0 mm

h1 mm

Tinst Nm

P

TOP 6 GS TOP 8 GS TOP 10 GS TOP 12 GS

45 51 60 75

M6x55 M8x60 M10x73 M12x90

10 12 14 18

55 60 70 85

5 12 20 35

8±0,5 10±0,5 12,5±0,5 16±0,5

134

Natural stone

Solid brick


pre-setting heavy duty anchors

Vorpa TOP

Steel anchors with ETA option 7 (CE marking) for non-cracked concrete

Non-cracked concrete

Natural stone

Technical data

TOP TS through-setting with 10.9 countersunk head screw

Code

Description

Lt mm

screws d x Lv mm

d0 mm

h1 mm

Tfix mm

Tinst Nm

Ch

11864 11866 11868 11870

TOP TOP TOP TOP

45 51 60 75

M6x80 M8x90 M10x100 M12x110

10 12 14 18

55 60 75 85

32 40 40 46

10 25 40 75

4 5 6 8

6 TS 8 TS 10 TS 12 TS

TOP DC through-setting with blind nut

Code

5720 5721 5722 5723

Description

Lt mm

screws d x Lv mm

d0 mm

h1 mm

Tfix mm

Tinst Nm

Ch

TOP 6 DC TOP 8 DC TOP 10 DC TOP 12 DC

45 51 60 75

M6x85 M8x102 M10x110 M12x135

10 12 14 18

55 60 75 85

32 40 40 46

10 25 40 75

4 5 6 8

TOP INOX A2 (A2 Stainless Steel) no accessories Code

714 715 716 717

Description

Lt mm

screws Ø mm

d0 mm

h1 mm

TOP INOX A2 6 TOP INOX A2 8 TOP INOX A2 10 TOP INOX A2 12

45 51 60 75

M6 M8 M10 M12

10 12 14 18

55 60 75 85

TOP INOX A4 (A4 Stainless Steel) no accessories

3714 3715 3716 3737

TOP INOX A4 6 TOP INOX A4 8 TOP INOX A4 10 TOP INOX A4 12

45 51 60 75

Screw length calculation: Lv = Lt + tfix

M6 M8 M10 M12

10 12 14 18

55 60 75 85

TOP INOX A2 BU with hexagonal head screw (A2 Stainless Steel) Code

717 718 719 727

Description

Lt mm

screws d x Lv mm

d0 mm

h1 mm

Tfix max mm

Tinst Nm

Ch

TOP INOX A2 6 BU TOP INOX A2 8 BU TOP INOX A2 10 BU TOP INOX A2 12 BU

45 51 60 75

M6x55 M8x65 M10x80 M12x100

10 12 14 18

55 60 70 85

10 14 20 25

10 25 40 75

10 13 17 19

10 14 20 25

10 25 40 75

10 13 17 19

TOP INOX A4 BU with hexagonal head screw (A4 Stainless Steel)

3717 3718 3719 3720

TOP INOX A4 6 BU TOP INOX A4 8 BU TOP INOX A4 10 BU TOP INOX A4 12 BU

45 51 60 75

M6x55 M8x65 M10x80 M12x100

10 12 14 18

55 60 70 85

135

h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length

Solid brick


pre-setting heavy duty anchors

Vorpa TOP

Steel anchors with ETA option 7 (CE marking) for non-cracked concrete

Non-cracked concrete

Natural stone

Technical data

TOP INOX A2 GS with hook-bolt (A2 Stainless Steel) Code

3775 3776 3777 3778

Description

Lt mm

hook-bolt d x Lg mm

d0 mm

h1 mm

Tinst Nm

P

T OP INOX A2 6 GS TOP INOX A2 8 GS TOP INOX A2 10 GS TOP INOX A2 12 GS

45 51 60 75

M6x55 M8x60 M10x73 M12x90

10 12 14 18

55 60 70 85

6 15 30 50

8±0,5 10±0,5 12,5±0,5 16±0,5

TOP INOX A2 OS with eyebolt (A2 Stainless Steel) Code

3795 3796 3797 3798

Description

Lt mm

eyebolt d x L0 mm

d0 mm

h1 mm

Tinst Nm

Ø mm

TOP INOX A2 6 OS TOP INOX A2 8 OS TOP INOX A2 10 OS TOP INOX A2 12 OS

45 51 60 75

M6x55 M8x60 M10x73 M12x90

10 12 14 18

55 60 70 85

6 15 30 50

10±0,5 11,8±0,5 14,5±0,5 17±0,5

TOP INOX A2 BD with threaded stud (A2 Stainless Steel) Code

Description

25705 TOP 6 BD A2 57 25706 TOP 8 BD A2 75 25707 TOP 10 BD A2 90

Lt mm

stud d x Lb mm

d0 mm

h1 mm

Tfix max mm

Tinst Nm

Ch

45 51 60

M6x55 M8x75 M10x90

10 12 14

55 60 70

10 10 20

10 25 40

10 13 17

10 10 20

10 25 40

10 13 17

TOP INOX A4 BD with threaded stud (A4 Stainless Steel)

5705 TOP 6 BD A4 57 5706 TOP 8 BD A4 75 5707 TOP 10 BD A4 90

45 51 60

M6x55 M8x75 M10x90

10 12 14

55 60 70

L TOP BD PROL. A2 with threaded stud (A2 Stainless Steel) Code

224 225 226 227

Description

Lt mm

stud d x Lb mm

d0 mm

h1 mm

Tinst Nm

Ch

TOP 6 BD PROL. A2 L. 200 TOP 6 BD PROL. A2 L. 220 TOP 6 BD PROL. A2 L. 250 TOP 6 BD PROL. A2 L. 300

45 45 45 45

200 220 250 300

10 10 10 10

55 55 55 55

6 6 6 6

10 10 10 10

136

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length

Solid brick


pre-setting heavy duty anchors

Vorpa TOP

Steel anchors with ETA option 7 (CE marking) for non-cracked concrete

Non-cracked concrete

Technical data Anchor type Installation data TOP –TOP A4 –TOP BU – TOP BU A4 d Anchor diameter L Anchor length hef Effective anchorage depth Tfix Fixture thickness d0 Drill hole diameter h1 Drill hole depth df Hole diameter in the fixture Tinst Torque moment

M6

M8

M10

M12

mm mm mm mm mm mm mm Nm

10 45 39,5 10 10 55 7 10

12 51 44,5 14 12 60 9 25

14 60 51,5 20 14 70 12 40

18 75 63 25 18 85 14 75

Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum thickness member

Scr,N Ccr,N Smin Cmin hmin

mm mm mm mm mm

120 60 65 45 135

135 75 90 70 135

155 90 135 85 140

190 120 165 115 160

Installation data TOP BP Anchor diameter Anchor length Effective anchorage depth Fixture thickness Drill hole diameter Drill hole depth Hole diameter in the fixture Torque moment

d L hef Tfix d0 h1 df Tinst

mm mm mm mm mm mm mm Nm

10 80 40,5 30 10 55 12 10

12 90 45,5 35 12 60 14 25

14 100 48,5 38 14 70 18 40

18 120 57 43 18 85 20 75

Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum thickness member

Scr,N Ccr,N Smin Cmin hmin

mm mm mm mm mm

120 60 65 45 5

135 75 90 70 135

155 90 135 85 140

190 120 165 115 160

KN

9 1,17 1,33 1,5

12

16

20 1,22 1,41 1,55

KN Nm

8 12,2

14,6 30

23,2 59,8

33,7 104,8

KN

7,5 1,17 1,33 1,5

9

12

16 1,22 1,41 1,55

KN Nm

7 10,7

12,8 26,2

20,3 52,3

29,5 91,7

Values where the reduction factor is included TOP A4 – TOP BU A4 (Design loads) Nrk,P KN 5 Pull out failure 5 VRk,S KN 4,5 Shear failure 8,2 MRK,S Nm 6,8 Bending moment 16,8

6,6 13 33,3

8,8 18,9 58,8

Values where the reduction factor Pull out failure Shear failure Bending moment

7,6 18,5 47,8

13,3 26,9 83,8

Characteristic values TOP – TOP BU – TOP BP Nrk,P C20/25 Pull out failure ψc C30/37 ψc C40/50 ψc C50/60 Shear failure Bending moment

VRk,S C20/25 MRK,S

Characteristic values TOP A4 – TOP BU A4 Nrk,P C20/25 Pull out failure ψc C30/37 ψc C40/50 ψc C50/60 Shear failure Bending moment

VRk,S C20/25 MRK,S

is included TOP BU – TOP BP (Design loads) Nrk,P KN 5 5,7 VRk,S KN 6,4 11,6 MRK,S Nm 9,7 24

Recommended loads TOP A4 - TOP BU A4 N Pull out failure T Shear failure M Bending moment Recommended loads TOP - TOP BU - BP Pull out failure Shear failure Bending moment

KN KN Nm

3,5 3,2 4,9

3,5 5,8 12

4,7 9,3 23,8

6,3 13,5 42

KN KN Nm

3,5 4,5 6,9

4 8,3 17,1

5,4 13,2 34,1

9,5 19,2 59,8

137

Natural stone

Solid brick


pre-setting heavy duty anchors

Vorpa TOP

Steel anchors with ETA option 7 (CE marking) for non-cracked concrete

Non-cracked concrete

Installation data

Top Anchor Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness

Scr Ccr Smin Cmin hmin

mm mm mm mm mm

M6 120 60 65 45 135

M8 135 75 90 70 135

M10 155 90 135 85 140

Permissible loads - applications in concrete C20/25 TOP TS - TOP DC TOP BD-TOP BD A2-TOP BD A4 TOP OS-TOP OS A2-TOP OP TOP GS-TOP GS A2 TOP A2 - - -

daN daN daN daN daN

M12 190 120 165 115 160 1 daN ≃1 kg

370 250 140 35 200

490 400 240 75 350

600 500 360 105 470

720 650 600 160 630

Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.

138

Natural stone

Solid brick


pre-setting heavy duty anchors

Vorpa TOP SA e SA A4

internal threaded short body steel anchor for hollow ceiling slaps

Concrete

Products group Suitable for • concrete • pre-stressed concrete hollow-ceiling slabs

TOP SA no accessories

TOP SA BU with 8.8 hexagonal screw

Pre-stressed concrete hollowceiling slabs

Application • Light metal structural work • Brackets and rails for industrial systems such as lighting, heating, ventilation • Suspended ceilings • Pipelines • Timber constructions • Sprinkler systems

product information Benefit • The optimized geometry reduces the energy required for fixing and allows its use even in narrowed spaces. • Suitable for all types of screws, threaded rods and eyebolts with metric thread.

Characteristics • Special short body steel anchor with ant-rotation design and expansion conical nut. • Suitable for hollow-ceiling slabs Benefit • The special design of the anchor allows the use both in hollow materials such as pre-stressed concrete hollow-core slabs both in solid materials with reduced thickness up to 5 cm. • The collar prevents slippage of the anchor into the hole and facilitates the installation since it is not necessary to respect the depth of drilling. Installation sequence

Installation • Pre-setting anchor Suggestion for use • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

Examples of applications

Air conditioning ceiling

Cable rails

possible applications

5 cm min.

Pre - stressed hollow-core concrete slabs = C45/55

Solid material with reduced thickness 139


pre-setting heavy duty anchors

Vorpa TOP SA e SA A4

internal threaded short body steel anchor for hollow ceiling slaps

Concrete

dati tecnici Products group

Pre-stressed concrete hollowceiling slabs

TOP SA - TOP SA A no accessories

Code Steel

Code A4 S. Steel

9650 9651 9652 9655 9656 9657

Description

d0 mm

Lt mm

M

h1 mm

Lv mm

Tinst mm

TOP SA 6 TOP SA 8 TOP SA 10 TOP SA A4 6 TOP SA A4 8 TOP SA A4 10

10 12 14 10 12 14

38 43 52 38 43 52

M6 M8 M10 M6 M8 M10

50 60 65 50 60 65

38 43 52 38 43 52

10 10 20 10 10 20

h1 = Min. hole depth Lt = Anchor length d0 = Hole diameter tfix = Fixture thickness tinst = Torque M = Screw Lv = Minimum depth screw + Tfix + washer hef = Effective anchorage depth Ch = Hex. wrench

TOP SA BU - TOP SA BU A with 8.8 hexagonal screw

Code Steel

Code A4 S. Steel

9659 9660 9661 9665 9666 9667

Description

Lt mm

screw dxL1

d0 mm

h1 mm

Tfix max

Ch

Tinst mm

TOP SA 6 BU TOP SA 8 BU TOP SA 10 BU TOP SA A 6 BU TOP SA A 8 BU TOP SA A 10 BU

38 43 52 38 43 52

M6x50 M8x60 M10x70 M6x50 M8x60 M10x70

10 12 14 10 12 14

50 60 65 50 60 65

8 12 17 8 12 17

10 13 17 10 13 17

10 10 20 10 10 20

Installation data Permissible loads-single application of anchor with 8.8 class screw on hollow prestressed concrete slab class ≥B55 (≥C45/55) Anchor

TOP SA BU M6

TOP SA BU M8 TOP SA BU M10

Slab thickness du (mm) 25-29 30-39 ≥40 25-29 30-39 ≥40 30-39 ≥40

Effective anchorage depth hef (mm) 35 35 35 40 40 40 45 45

Torque Tinst (Nm) 10 10 10 10 10 10 20 20

Permissible load Kn 0,6 0,8 1,9 0,6 0,8 1,9 1,1 2,9

Minimum spacing (mm) 75 85 105 75 85 105 85 105

Minimum edge distance (mm) 110 110 110 110 110 110 110 110

Permissible loads-single application of anchor with A4-70 class screw on hollow prestressed concrete slab class ≥B55 (≥C45/55) Anchor

TOP SA A4 M6

TOP SA A4 M8 TOP SA A4 M10

Slab thickness du (mm) 25-29 30-39 ≥40 25-29 30-39 ≥40 30-39 ≥40

Effective anchorage depth hef (mm) 35 35 35 40 40 40 45 45

Torque Tinst (Nm) 10 10 10 10 10 10 20 20

140

Permissible load Kn 0,6 0,8 1,9 0,6 0,8 1,9 1,1 2,9

Minimum spacing (mm) 75 85 105 75 85 105 85 105

Minimum edge distance (mm) 110 110 110 110 110 110 110 110


pre-setting heavy duty anchors

Vorpa AV Steel anchors

Non-cracked concrete

Natural stone

Solid brick

Products group AV no accessories

Suitable for • Non-cracked concrete • Natural stone • Solid brick

AV BU with 8.8 hexagonal screw

AV BD with stud

AV OS with eyebolt

To fix • Stairs • Window elements • Railings and balustrades • Pipes • Steel structures • Gates • Façades • Machineries • Bars Software Vorpa Calcul Anchor

AV GS with hook-bolt

Examples of applications

AV OA with folded hook-bolt

AV INOX A2 (A2 Stainless Steel) AV INOX A4 (A4 Stainless Steel) no accessories AV INOX A2 BU (A2 Stainless Steel) AV INOX A4 BU (A4 Stainless Steel) with hexagonal head screw

AV INOX A2 BD (A2 Stainless Steel) with threaded stud

Product information Characteristics • Expansion anchor made of galvanized steel or stainless steel composed of anti-rotation cold formed body, expansion conical nut and accessory. • When the screw or hexagon nut is tightened, the cone is pulled into the expansion sleeve and expands it against the hole wall. Benefits • Wide range of accessories • Anti-rotation design with two lateral wings • Surface-flush fixing allows the attached item to be removed and refitted several times • Plastic cap protects against contamination with drilling dust and ensures the thread remains free-running

Installation • Pre-setting anchor Suggestion for use • Choose the most suitable accessory in relation to the application to carry out • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

141


pre-setting heavy duty anchors

Vorpa AV Steel anchors

Non-cracked concrete

Natural stone

Installation sequence

Technical data

AV no accessories

Code

550 551 552 553 554

Description

Lt mm

for screws Ø mm

d0 mm

h1 mm

AV 6 AV 8 AV 10 AV 12 AV 16

47 55 65 75 92

M6 M8 M10 M12 M16

12 14 16 20 24

55 65 75 85 105

AV BU with 8.8 hexagonal screw

Code

260 262 263 264 261

Description

Lt mm

screws d x Lv mm

d0 mm

h1 mm

Tfix max mm

Tinst Nm

Ch

AV 6 BU AV 8 BU AV 10 BU AV 12 BU AV 16 BU

47 55 65 75 92

M6x55 M8x65 M10x80 M12x100 M16x100

12 14 16 20 24

55 65 75 85 105

10 12 15 20 20

10 25 50 85 150

10 13 17 19 24

Tfix max mm

Tinst Nm

Ch

6 15 15 15 15 15 30 50 70

10 13 13 13 13 13 17 19 24

AV BD with stud

Code

250 251 252 255 256 257 253 254 259

Description

Lt mm

for screws d x Lv mm

d0 mm

h1 mm

AV 6 BD 60 AV 8 BD 50 AV 8 BD 75 AV 8 BD 100 AV 8 BD 120 AV 8 BD 130 AV 10 BD 85 AV 12 BD 105 AV 16 BD 135

47 30 55 55 55 55 65 75 92

M6x60 M8x55 M8x75 M8x100 M8x120 M8x132 M10x85 M12x115 M16x135

12 14 14 14 14 14 16 20 24

55 65 65 65 65 65 75 85 105

142

10 5 15 35 55 65 15 25 30

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length

Solid brick


pre-setting heavy duty anchors

Vorpa AV Steel anchors

Non-cracked concrete

Natural stone

Technical data

AV OS with eyebolt

Code

280 281 282 283 284

Description

Lt mm

for screws d x L0 mm

d0 mm

h1 mm

Tinst Nm

Ø

AV 6 OS AV 8 OS AV 10 OS AV 12 OS AV 16 OS

47 55 65 75 92

M6x55 M8x60 M10x73 M12x90 M16x95

12 14 16 20 24

55 65 75 85 105

5 12 25 40 80

10±0,5 11,8±0,5 14,5±0,5 17±0,5 23±0,5

AV GS with hook-bolt

Code

290 291 292 293 294

Description

Lt mm

hook bolt d x Lg mm

d0 mm

h1 mm

Tinst Nm

P

AV 6 GS AV 8 GS AV 10 GS AV 12 GS AV 16 GS

47 55 65 75 92

M6x55 M8x60 M10x73 M12x90 M16x95

12 14 16 20 24

55 65 75 85 105

5 12 25 40 80

8±0,5 10±0,5 12,5±0,5 16±0,5 19±0,5

AV OA with folded hook-bolt

Code

Description

311 AV 6 OA 312 AV 8 OA

Lt mm

hook bolt d x Lg mm

d0 mm

h1 mm

Tinst Nm

P

47 55

M6x55 M8x65

12 14

55 65

5 12

13±0,5 16±0,5

AV INOX A2 no accessories (A2 Stainless Steel) Code

3550 3551 3552 3547

Description

Lt mm

for screws d x Lv mm

d0 mm

h1 mm

AV INOX A2 6 AV INOX A2 8 AV INOX A2 10 AV INOX A2 12

47 55 65 75

M6 M8 M10 M12

12 14 16 20

55 65 75 85

AV INOX A4 no accessories (A4 Stainless Steel)

4550 AV INOX A4 6 4551 AV INOX A4 8 4552 AV INOX A4 10

47 55 65

M6 M8 M10

12 14 16

143

55 65 75

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length

Solid brick


pre-setting heavy duty anchors

Vorpa AV Steel anchors

Non-cracked concrete

Natural stone

Technical data AV INOX A2 BU with hexagonal head screw (A2 Stainless Steel) Code

3260 3262 3263 3264

Description

AV INOX A2 AV INOX A2 AV INOX A2 AV INOX A2

6 BU 8 BU 10 BU 12 BU

Lt mm

screws d x Lv mm

d0 mm

h1 mm

Tfix max mm

Tinst Nm

Ch

47 55 65 75

M6x55 M8x65 M10x80 M12x100

12 14 16 20

55 65 75 85

10 15 15 20

10 25 50 85

10 13 17 19

AV INOX A4 BU with hexagonal head screw (A4 Stainless Steel)

4260 AV INOX A4 6 BU 4262 AV INOX A4 8 BU 4263 AV INOX A4 10 BU

47 55 65

M6x55 M8x65 M10x80

12 14 16

55 65 75

10 15 15

10 25 50

10 13 17

AV INOX A2 BD with threaded stud (A2 Stainless Steel) Code

Description

3250 AV INOX A2 6 BD 3252 AV INOX A2 8 BD 3253 AV INOX A2 10 BD

Lt mm

stud d x Lb mm

d0 mm

h1 mm

Tfix max mm

Tinst Nm

Ch

47 55 65

M6x60 M8x75 M10x85

12 14 16

55 65 75

10 15 15

10 25 40

10 13 17

Installation data

AV Anchor Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness

Scr Ccr Smin Cmin hmin

mm mm mm mm mm

M6 160 90 70 60 100

M8 180 100 80 70 100

M10 220 120 90 80 100

M12 280 150 120 100 120

Permissible loads - applications in concrete C20/25 AV BU - AV BU A2/A4 AV - AV A2/A4 - AV BD AV OS AV GS AV OA A2/A4 Stainless Steel screws - - -

daN daN daN daN daN daN

M16 320 170 130 115 140

M20 440 185 145 125 160

1 daN ≃1 kg 230 220 140 35 35 230

420 350 240 75 75 420

590 470 360 100 100 590

750 700 600 110 110

1080 800 700 200

1250 950

Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.

144

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length

Solid brick


pre-setting heavy duty anchors

Vorpa AVZ

Steel expansion shield anchors

Non-cracked concrete

Natural stone

Solid brick

Perforated bricks

Products group AVZ no accessories

Suitable for • Non-cracked concrete • Natural stone • Solid brick • Perforated brick

AVZ BU with 8.8 hexagonal screw

To fix • Heavy structural works • Machineries • Stairs • Balustrades • Gates • Façades • Railings

Software Vorpa Calcul Anchor

Examples of applications

Product information Characteristics • Steel anchor composed of 4 segments anti-rotation cold formed body, expansion conical nut and accessory. Benefits • Anti-rotation during the installation procedure • Smooth expansion thanks to the four segments body • Suitable for applications on poor-quality concrete and non- homogeneous materials • High expansion and grip

Installation • Pre-setting anchor Suggestion for use • Choose the most suitable accessory in relation to the application to carry out • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

Installation sequence

145


pre-setting heavy duty anchors

Vorpa AVZ

Steel expansion shield anchors

Non-cracked concrete

Natural stone

Solid brick

Technical data

AVZ no accessories

Code

831 832 833 834 835

Description

Lt mm

for screws Ă˜ mm

d0 mm

h1 mm

AVZ 6 AVZ 8 AVZ 10 AVZ 12 AVZ 16

40 50 60 80 100

M6 M8 M10 M12 M16

10 14 16 20 25

50 60 70 90 110

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner

AVZ BU with 8.8 hexagonal head screw

Code

841 842 843 844 845

Description

Lt mm

screws d x Lv mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Ch

AVZ AVZ AVZ AVZ AVZ

40 50 60 80 100

M6x55 M8x70 M10x80 M12x100 M16x130

10 14 16 20 25

50 60 70 90 110

15 20 20 20 25

10 25 50 85 150

10 13 17 19 24

6 BU 8 BU 10 BU 12 BU 16 BU

Installation data

AVZ Anchor Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness

Scr Ccr Smin Cmin hmin

mm mm mm mm mm

M6 200 100 80 50 100

M8 220 100 80 50 100

M10 260 130 100 65 150

Permissible loads - applications in concrete C20/25 AVZ BU - - -

daN

M12 320 160 130 80 160

M16 440 220 170 110 220

1 daN ≃1 kg 330

450

530

750

1200

Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.

146

Perforated bricks


pre-setting heavy duty anchors

Vorpa VHM

Zamak expansion shield anchors

Non-cracked concrete

Natural stone

Solid brick

Perforated bricks

Products group VHM no accessories

VHM BU with 8.8 hexagonal screw

Suitable for • Non-cracked concrete • Natural stone • Solid brick • Perforated brick

To fix • Heavy structural works • Machineries • Railings • Profiles • Façades

Software Vorpa Calcul Anchor

Examples of applications

Product information Characteristics • Zamak anchor composed of 4 shells cold formed body, with anti-rotation design, expansion conical nut and accessory. Benefits • Anti-rotation during the installation • No corrosion body, suitable for wet area, old and non-homogeneous materials • Smooth expansion thanks to the four shells body • The body is made of zamak (96% zinc. 4% alluminium)

Installation • Pre-setting anchor Suggestion for use • Choose the most suitable accessory in relation to the application to carry out • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

Installation sequence

147


pre-setting heavy duty anchors

Vorpa VHM

Zamak expansion shield anchors

Non-cracked concrete

Natural stone

Solid brick

Technical data

VHM no accessories

Code

811 812 813 814 815

Description

Lt mm

for screws mm

d0 mm

h1 mm

VHM 6 VHM 8 VHM 10 VHM 12 VHM 16

47 50 57 72 107

M6 M8 M10 M12 M16

12 14 16 20 25

55 60 70 80 115

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner

VHM BU with 8.8 hexagonal screw

Code

821 822 823 824 825

Description

Lt mm

screws d x Lv mm

d0 mm

h1 mm

Tfix max mm

Tinst Nm

Ch

VHM 6 BU VHM 8 BU VHM 10 BU VHM 12 BU VHM 16 BU

47 50 57 72 107

M6x55 M8x70 M10x80 M12x100 M16x150

12 14 16 20 25

55 60 70 80 115

10 15 20 20 20

10 25 50 80 150

10 13 17 19 24

Installation data

VHM Anchor Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness

Scr Ccr Smin Cmin hmin

mm mm mm mm mm

M6 200 100 85 50 100

M8 220 100 85 50 100

M10 260 130 105 65 150

M12 320 160 135 80 160

Permissible loads - applications in concrete C20/25 VHM BU - - -

daN

M16 440 225 180 110 200 1 daN ≃1 kg

300

400

500

600

1200

Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.

148

Perforated bricks


pre-setting heavy duty anchors

Vorpa AVZ.G

Sherardise steel shield anchors

Non-cracked concrete

Natural stone

Solid brick

Perforated bricks

Products group AVZ.G no accessories

AVZ.G BU with 8.8 hexagonal head screw

Suitable for • Non-cracked concrete • Natural stone • Solid brick • Perforated brick

To fix • Heavy structural works • Machineries • Railings • Balustrades • Gates • Profiles • Stairs • Façades Software Vorpa Calcul Anchor

Examples of applications

Product information Characteristics • Steel anchor made of sherardise steel composed of 4 segments anti-rotation cold formed body, expansion conical nut and steel spring plus accessory. Benefits • Anti-rotation during the installation procedure • Smooth expansion thanks to the four segments body • Indicated also for oversize holes • Suitable for porous and non-homogeneous materials; it can be used even in case of defective base materials.

Installation • Pre-setting anchor Suggestion for use • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

Installation sequence

149


pre-setting heavy duty anchors

Vorpa AVZ.G

Sherardise steel shield anchors

Non-cracked concrete

Natural stone

Solid brick

Technical data

AVZ.G no accessories

Code

1831 1832 1833 1834 1835

Description

Lt mm

for screws Ă˜ mm

d0 mm

h1 mm

AVZ.G 6 AVZ.G 8 AVZ.G 10 AVZ.G 12 AVZ.G 16

40 50 60 80 100

M6 M8 M10 M12 M16

12 14 16 20 28

45 55 65 85 105

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner

AVZ.G BU with 8.8 hexagonal head screw

Code

1841 1842 1843 1844 1845

Description

Lt mm

screws d x Lv mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Ch

AVZ.G 6 BU AVZ.G 8 BU AVZ.G 10 BU AVZ.G 12 BU AVZ.G 16 BU

40 50 60 80 100

M6x55 M8x70 M10x80 M12x100 M16x130

12 14 16 20 28

45 55 65 85 105

15 20 20 20 25

10 25 50 85 150

10 13 17 19 24

Installation data

AVZ.G Anchor Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness

Scr Ccr Smin Cmin hmin

mm mm mm mm mm

M6 200 100 80 50 100

M8 220 100 80 50 100

M10 260 130 100 65 150

Permissible loads - applications in concrete C20/25 AVZ.G - - -

daN

M12 320 160 130 80 160

M16 440 220 170 110 220

1 daN ≃1 kg 370

580

760

1140

2000

Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.

150

Perforated bricks


through-setting heawy duty anchors

Vorpa VHS

Steel anchors with European Technical Assessment

Non-cracked concrete

Natural stone

Solid brick

Products group VHS C [*] with 8.8 hexagonal head screw

Approved for • Non-cracked concrete C20/25 - C50/60 - M6-M12 • Non-cracked concrete C12/15

VHS B with threaded stud

Also suitable for • Natural stone • Solid brick

VHS F with 10.9 countersunk head

To fix • Plates • Plants engineering • Stairs • Window and door frames • Profiles • Gates • Railings

[*]

European Technical Assessment Option 8 for non-cracked concrete

VHS OS with eyebolt

Software Vorpa Calcul Anchor

VHS D INOX A2 (A2 Stainless Steel) with hexagonal head screw

For version with ETA: As it can also be used on concrete with different strength characteristics, as specified in ETA, on compact natural stone and others materials (exception not included in ETA), specific on-site tests by the user are necessary VHS FI INOX A2 (A2 Stainless Steel) with countersunk head

VHS PF with 8.8 hexagonal head screw Examples of applications

151


through-setting heawy duty anchors

Vorpa VHS

Steel anchors with European Technical Assessment

Non-cracked concrete

Natural stone

Solid brick

Product information Installation • Through-setting anchor

Characteristics • Through steel anchor with slots on the body and on the expansion conical nut

Suggestion for use • Choose the most suitable accessory in relation to the application to carry out • Choose the right size of the anchor according the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

Benefits • European Technical Assessment option 8 • Smooth expansion thanks to the slots on the body and on the expansion conical nut • High setting quickness through the object to be fixed • High performances Installation sequence

Technical data

VHS C with 8.8 hexagonal head screw

Code

Description

Lt mm

for screws d x Lv mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Ch

* 1725 1726 1724 * 1727 1728 3473 4473 * 1729 1730 3475 4475 * 1732 5560 5561 5562

VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C VHS C

45 65 100 50 70 100 120 60 80 100 120 130 90 110 130

M6x50 M6x70 M6x100 M8x55 M8x75 M8x100 M8x120 M10x65 M10x80 M10x100 M10x120 M10x130 M12x90 M12x110 M12x130

8 8 8 10 10 10 10 12 12 12 12 12 16 16 16

50 50 50 55 55 55 55 60 60 60 60 60 85 85 85

4 24 54 5 25 45 65 5 25 45 65 75 10 30 50

10 10 10 25 25 25 25 40 40 40 40 40 65 65 65

10 10 10 13 13 13 13 17 17 17 17 17 19 19 19

8/4-45 8/24-65 8/54-100 10/5-50 10/25-70 10/45-100 10/65-120 12/5-60 12/25-80 12/45-100 12/65-120 12/75-130 16/10-90 16/30-110 16/50-130

* Non included in ETA

152

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length


through-setting heawy duty anchors

Vorpa VHS

Steel anchors with European Technical Assessment

Non-cracked concrete

Natural stone

Technical data

VHS D INOX A2 (A2 Stainless Steel) with hexagonal head screw Code

2525 2526 2500 2527 2528 2473 5473 2529 2530 2475 5475 5476 5477 5479

Description

Lt mm

for screws d x Lv mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Ch

VHS D A2 8/4-45 VHS D A2 8/24-65 VHS D A2 8/54-100 VHS D A2 10/5-50 VHS D A2 10/25-70 VHS D A2 10/45-100 VHS D A2 10/65-120 VHS D A2 12/5-60 VHS D A2 12/25-80 VHS D A2 12/45-100 VHS D A2 12/65-120 VHS D A2 16/10-90 VHS D A2 16/30-110 VHS D A2 16/50-130

45 65 100 50 70 100 120 60 80 100 120 90 110 130

M6x50 M6x70 M6x100 M8x55 M8x75 M8x100 M8x120 M10x65 M10x80 M10x100 M10x120 M12x90 M12x110 M12x130

8 8 8 10 10 10 10 12 12 12 12 16 16 16

50 50 50 55 55 55 55 60 60 60 60 85 85 85

4 24 54 5 25 45 65 5 25 45 65 10 30 50

10 10 10 25 25 25 25 40 40 40 40 65 65 65

10 10 10 13 13 13 13 17 17 17 17 19 19 19

VHS B with threaded stud

Code

Description

Lt mm

stud d x Lb mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Ch

535 536 2534 537 538 2538 539 540 2540 2541 55561 55562 52536

VHS B VHS B VHS B VHS B VHS B VHS B VHS B VHS B VHS B VHS B VHS B VHS B VHS B

45 65 100 50 70 100 60 80 100 120 110 130 140

M6x57 M6x73 M6x110 M8x60 M8x80 M8x102 M10x75 M10x95 M10x110 M10x130 M12x110 M12x130 M12x140

8 8 8 10 10 10 12 12 12 12 16 16 16

50 50 50 55 55 55 60 60 60 60 85 85 85

4 24 54 5 25 45 5 25 45 65 30 50 60

6 6 6 15 15 15 30 30 30 30 65 65 65

10 10 10 13 13 13 17 17 17 17 19 19 19

8/4-45 8/24-65 8/54-100 10/5-50 10/25-70 10/45-100 12/5-60 12/25-80 12/45-100 12/65-120 16/30-110 16/50-130 16/60-140

VHS F with 10.9 countersunk head

Code

4525 4526 4537 4527 4528 4534 4529 4530 4535 5565 5566

Description

Lt mm

screws d x Lv mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Ch

VHS F 8/4-45 VHS F 8/24-65 VHS F 8/54-100 VHS F 10/5-50 VHS F 10/25-70 VHS F 10/45-100 VHS F 12/5-60 VHS F 12/25-80 VHS F 12/45-100 VHS F 16/10-90 VHS F 16/30-110

45 65 100 50 70 100 60 80 100 90 110

M6x50 M6x70 M6x100 M8x60 M8x80 M8x100 M10x65 M10x80 M10x100 M12x90 M12x110

8 8 8 10 10 10 12 12 12 16 16

50 50 50 55 55 55 60 60 60 85 85

4 24 54 5 25 45 5 25 45 10 30

10 10 10 25 25 25 40 40 40 65 65

4 4 4 5 5 5 6 6 6 8 8

153

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length

Solid brick


through-setting heawy duty anchors

Vorpa VHS

Steel anchors with European Technical Assessment

Non-cracked concrete

Natural stone

Technical data

VHS FI INOX A2 with A2 Stainless Steel countersunk Code

5530 5531 5537 5532 5533 5529 5534 5535 5536

Description

Lt mm

screws d x Lv mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Ch

VHS FI A2 8/4-45 VHS FI A2 8/24-65 VHS FI A 8/54-100 VHS FI A2 10/5-50 VHS FI A2 10/25-70 VHS FI A2 10/45-100 VHS FI A2 12/5-60 VHS FI A2 12/25-80 VHS FI A2 12/45-100

45 65 100 50 70 100 60 80 100

M6x50 M6x70 M6x100 M8x60 M8x80 M8x100 M10x65 M10x80 M10x100

8 8 8 10 10 10 12 12 12

50 50 50 55 55 55 60 60 60

4 24 54 5 25 45 5 25 45

10 10 10 25 25 25 40 40 40

4 4 4 5 5 5 6 6 6

VHS OS with eyebolt

Code

Description

575 VHS OS 8/45 576 VHS OS 10/50 577 VHS OS 12/60

Lt mm

45 50 60

eyebolt d x LO mm

d0 mm

h1 mm

Tinst Nm

Ch

M6x55 M8x60 M10x73

8 10 12

55 60 85

6 15 30

10±0,5 11,8±0,5 14,5±0,5

154

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length

Solid brick


through-setting heawy duty anchors

Vorpa VHS

Steel anchors with European Technical Assessment

Non-cracked concrete

Installation data

VHS Anchor Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness

Scr Ccr Smin Cmin hmin

M6 180 100 95 50 80

mm mm mm mm mm

M8 240 120 120 60 100

M10 250 150 145 75 120

Permissible loads - applications in concrete C20/25 Screws cl. 10.9 Screws A2 Threaded stud cl. 5.8 VHS OS

M12 280 170 175 90 150 1 daN ≃1 kg

daN daN daN daN

180 140 105 35

250 220 160 75

Permissible loads - applications in solid brick compression resistance 18/20 N/mm2

400 380 280 100

930 700 540

1 daN ≃1 kg

Screws cl. 8,8 daN 100* 160* 280* 390* * Indicative values - For applications on solid bricks is not possible to show specific loading values because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department. - - -

Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.

Installation data M6

M8

M10

M12

mm mm mm mm mm Nm

8 31 8 50 9 10

10 35 10 55 11 25

12 40 12 60 13 40

16 60 16 85 17 65

Scr,N Ccr,N Smin Cmin hmin

mm mm mm mm mm

93 46,5 95 50 80

105 52,5 120 60 100

120 60 145 75 120

180 90 175 90 150

Nrk,P C20/25

KN

6 1 1 1

7,5 1 1 1

12 1 1 1

20 1 1 1

VRk,S C20/25 MRK,S

KN Nm

7,5 12,2

12 30

20 59,8

30 104,8

Nrk,P VRk,S MRK,S

KN KN Nm

4 6 9,7

5 9,6 24

8 16 47,8

13 24 83,8

N T M

KN KN Nm

2,5 4,2 6,5

3,5 6,8 17

5,7 11,4 34

9,2 17 59,5

Anchor type Installation data VHS C Anchor diameter Effective anchorage depth Drill hole diameter Drill hole depth Hole diameter in the fixture Torque moment

d hef d0 h1 df Tinst

Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum thickness member Characteristic values VHS C Pull out failure c C30/37 c C40/50 c C50/60 Shear failure Bending moment Values where the reduction factor Pull out failure Shear failure Bending moment Recommended loads VHS C Pull out failure Shear failure Bending moment

155

Natural stone

Solid brick


through-setting heawy duty anchors

Vorpa VHS

Steel anchors with European Technical Assessment

Non-cracked concrete

Natural stone

Technical data

VHS PF with 8.8 hexagonal head screw

Code

555 1558 564 1567 580 1586 587 1592 1593

Description

VHS PF VHS PF VHS PF VHS PF VHS PF VHS PF VHS PF VHS PF VHS PF

14/10-70 14/20-80 14/40-100 14/60-120 16/15-80 16/35-100 16/55-120 16/75-140 16/95-160

Lt mm

screws d x Lv mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Ch

70 80 100 120 80 100 120 140 160

M10x70 M10x80 M10x100 M10x120 M12x80 M12x100 M12x120 M12x140 M12x160

14 14 14 14 16 16 16 16 16

65 65 65 65 70 70 70 70 70

10 20 40 60 15 35 55 75 95

40 40 40 40 75 75 75 75 75

17 17 17 17 19 19 19 19 19

A2 stainless steel version available

Installation data

VHS PF Anchor Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness

Scr Ccr Smin Cmin hmin

M10 250 150 145 75 120

mm mm mm mm mm

Permissible loads - applications in concrete C20/25 VHS PF - - -

M12 280 170 175 90 150 1 daN ≃1 kg

daN

600

850

Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.

Esempi di applicazione

156

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner Lb = Stud length L0 = Eyebolt length Lg = Hook-bolt length

Solid brick


through-setting heawy duty anchors

Vorpa VTS steel anchors

Non-cracked concrete

Natural stone

Solid brick

Products group Suitable for • non-cracked concrete • natural stone • solid brick

VTS

with 8.8 hexagonal head screw

suitable to fix • stairs • window and door frames • profiles • gates

Product information Installation • Through-setting anchor

Characteristics • Through steel anchor with slots on the body and on the expansion conical nut

Consigli per l’utilizzo • Choose the most suitable accessory in relation to the application to carry out • Choose the right size of the anchor according the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

Benefits • Smooth expansion thanks to the slots on the body and on the expansion conical nut • High setting quickness through the object to be fixed

Installation sequence

Technical data Code

8883 8884 8885 8886 8887 8888 8889 8890 8891 8892 8893

Description

Lt mm

d0 mm

h1 mm

tfixmax mm

Tinst mm

Ch

VTS VTS VTS VTS VTS VTS VTS VTS VTS VTS VTS

45 70 90 55 80 100 65 80 100 75 110

8 8 8 10 10 10 12 12 12 16 16

45 45 45 50 50 50 60 65 65 65 70

5 30 50 10 35 55 10 20 40 15 45

10 10 10 25 25 25 50 50 50 75 75

10 10 10 13 13 13 13 17 17 17 17

8/5-45 8/30-70 8/50-90 10/10-55 10/35-80 10/55-100 12/10-65 12/20-80 12/40-100 16/15-75 16/45-110

Installation data Anchor type Critical axial spacing Critical edge distance Minimum structural thichness

Scr Ccr hmin

mm mm mm

M6 120 60 100

M8 135 67,5 100

M10 165/180 85/90 100

daN

90

140

230/250

Permissable loads - Applications in concrete C20/25 Screws cl. 8.8 - - -

M12 180/195 90/97,5 130 1 daN ≃1 kg 255/280

Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads

157

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner


pre-setting heavy duty anchors

Vorpa VO Brass anchors

Wood

Concrete

Natural stone

Products group VO no accessories

Suitable for • Wood • Concrete • Natural stone • Solid brick

To fix • Railings • Profiles • Stairs • Wood columns

VO S with double threaded screw for wood column

Examples of applications

Product information Characteristics • Brass anchor for metric screws • The version VO S is composed of a brass anchor and a double threaded screw for wood column Benefits • Smooth expansion thanks to the slots on the body • Special surface structure prevents it rotating in the hole • Expansion carried out by screwing the accessory

Installation • Pre-setting anchor Suggestion for use • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

Installation sequence

VO anchor

VO S anchor 158

Solid brick


pre-setting heavy duty anchors

Vorpa VO Brass anchors

Wood

Concrete

Natural stone

Technical data

VO no accessories

Code

Description

50580 581 582 583 584 585 50587

VO 4 VO 5 VO 6 VO 8 VO 10 VO 12 VO 16

Lt mm

for screws Ø mm

d0 mm

h1 mm

M4 M5 M6 M8 M10 M12 M16

5 6,5 8 10 12 15 20

20 30 30 35 40 45 50

16 22 24 30 35 40 45

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner

VO S with double threaded screw for wood column Code

Description

408 VO S 8/90 409 VO S 10/120

Lt mm

30 35

screws Ø mm

d0 mm

h1 mm

M8x90 M10x120

10 12

35 40

Installation data

VO Anchor Permissible loads - applications in concrete C20/25 VO daN - - -

M5

M6

M8

M10

50

140

200

250

M12 M16 1 daN ≃1 kg 340 450

Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.

159

Solid brick


through-setting heawy duty anchors

Vorpa safety threaded nuts Safety zincplated and A2 stainless steel threaded nuts product group Per fix • Windows frame • Railings • Garden furniture • Road sign • gazebo

Characteristics: shear threaded nut • Anti-burglar nut with one-sided clamping system • With a torque of about 19 Nm, the hexagonal head detaches without giving the possibility of tampering and dissambly of the object Characteristics: threaded nut AF DRIVE • The special design of the permanent AF nut once brought to tightening, guarantees the inviolability of the mechanical anchor technical data DTS P INOX A Safety A2 stainless steel threaded nut with shear head and through hole Code

58999 59000 59001 59006

Description

DTS P DTS P DTS P DTS P

M M M M

Internal threaded

6/13 8/17 10/19 12/19

DTS PZ Safety zincplated threaded nut with shear head and through hole

Hexagon size

Tinst

Code

Description

Internal threaded

Nm indicative

Tinst

Hexagon size

Nm indicative

M 6 M 8 M 10 M 12

13 17 19 19

15-25 30-40 75-85

59000Z 59001Z 59002Z

DTS PZ M 8/17 DTS PZ M 10/19 DTS PZ M 12/22

M 8 M 10 M 12

17 19 22

15-25 30-40 75-85

M 8 M 10

13 17

15-25 30-40

58996Z 58976Z

DTS PZ M 8/13 DTS PZ M 10/17

M 8 M 10

13 17

15-25 30-40

Reduced hexagonal size version:

58996 58997

DTS P M 8/13 DTS P M 10/17

90840

90841

Ø 90842

Ø 90843

Code

90840 90841 90842 90843 4042 4049

DTS INOX A Safety A2 stainless steel M8 threaded nut with shear head

Description

Internal threaded

DTS COUNTERSUNK DTS DTS 8/12 DTS 8/10 A2 S.S. WASHER 10x20x2 A2 S.S. WASHER 12x22x2,5

M 8 M 8 M 8 M 8

Hexagon size

15 13 15 15

Ø

90840Z

90841Z

Ø 90842Z

Ø 90843Z

Tinst

Code

19 19 19 19

90840Z 90841Z 90842Z 90843Z

Description

Nm indicative

12 10

DTS Z COUNTERSUNK DTS Z DTS Z 8/12 DTS Z 8/10

TORQUE TOOL FOR ANCHOR AND NUT AF

Code

Description

72589 72592 72590 72591

AF AF NUT AF NUT AF

M 8 M 10 M 8 M 10

DTS Z Safety zincplated M8 threaded nut with shear head

Nut

Mechanical anchor VHS AF

art. 72590 art. 72591

code 5717/5710/5712

A mm

B mm

16,10 20,10

7,30 9,10

160

Internal threaded

M 8 M 10

Internal threaded

M 8 M 8 M 8 M 8

Hexagon size

15 13 15 15

Ø

Tinst

Nm indicative

12 10

19 19 19 19


through-setting heawy duty anchors

Vorpa Security Anchor VHS

Special permanent temper-proof fixings as protection against burglary and thievery

Non-cracked concrete

Natural stone

Solid brick

Products group VHS AE with A2 stainless steel shear nut

Suitable for • Non-cracked concrete • Natural stone • Solid brick

VHS Z with A2 stainless steel shear nut

VHS AF with steel shear nut AF

VHS CX with Torx bit 8.8 screw VHS CX INOX A2 with A2 stainless steel Torx bit screw

Examples of applications

161

To fix • Window and door frames • Gates • Railings • Iron bars • Traffic signals • Garden fittings


through-setting heawy duty anchors

Vorpa Security Anchor VHS

Special permanent temper-proof fixings as protection against burglary and thievery

Non-cracked concrete

Natural stone

Product information Installation • Through-setting anchor

Characteristics • Through steel anchor with slots on the body and on the expansion conical nut completed of shear nut.

Suggestion for use • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

Benefits • Smooth expansion thanks to the slots on the body and on the expansion conical nut • High setting quickness through the object to be fixed • High performances • Shear nut

Installation sequence

Technical data VHS AF sleeve anchor is a through fixing, thus ensuring fast and simple installation. Ideal for many security applications in a wide variety of base materials. The unique AF drive permanent nut offers an accurate torque controlled security fixing which can be re-torqued if necessary. Reduced hole diameter compared to TOP version.

VHS AF with AF steel shear nut

Code

Description

7517 VHS AF 10/5-50 7510 VHS AF 10/25-70 7512 VHS AF 10/55-100

Lt mm

screws d x Lb mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Ch

50 70 100

M8x55 M8x75 M8x100

10 10 10

50 50 50

5 25 55

15 15 15

AF M8 AF M8 AF M8

AF DRIVER SOCKET AND AF PERMANENT NUT

Code

Description

72589 72592 72590 72591

AF M8 AF M10 DADO AF M8 DADO AF M10

internal thread

for nut

for anchor TOP AF

art. 72590 art. 72591

art. 7578/7562/7563 -

M8 M10

162

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner

Solid brick


through-setting heawy duty anchors

Vorpa Security Anchor VHS

Special permanent temper-proof fixings as protection against burglary and thievery

Non-cracked concrete

Natural stone

Technical data Security anchors with shear nut for final fixing of windows, iron fences, gates, etc. Suitable for every compact building materials. Exceeding a torque of 19 Nm the hexagonal head takes off giving no chance to slip off the fixing. Hexagonal head and washer are made in A2 Stainless Steel. Reduced hole diameter compared to TOP version.

VHS AE with A2 stainless steel shear nut

Code

Description

517 VHS AE 10/8-60 510 VHS AE 10/28-75 512 VHS AE 10/48-100

Lt mm

screws d x Lb mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Ch

60 75 100

M8x60 M8x75 M8x100

10 10 10

55 55 55

8 28 48

* * *

15 15 15

* Approximate breaking torque at 19Nm

VHS Z with countersunk head and A2 stainless steel shear nut

Code

Description

2588 VHS Z 10/18-65 2510 VHS Z 10/38-85

Lt mm

screws d x Lb mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Ch

65 85

M8x60 M8x80

10 10

55 55

18 38

* *

15 15

* Approximate breaking torque at 19Nm

Installation sequence

Examples of applications

163

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner

Solid brick


through-setting heawy duty anchors

Vorpa Security Anchor VHS

Special permanent temper-proof fixings as protection against burglary and thievery

Non-cracked concrete

Natural stone

Technical data Security anchors for final fixing of windows, iron fences, gates, etc. granting protection against burglary and thievery. Head screw is characterized by Torx bit T40. Zamak star must be hammered into Torx bit making the anchor impossible to remove. Reduced hole diameter compared to TOP version.

VHS CX with Torx bit 8.8 screw

Description

Lt mm

screw d x Lb mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Torx bit

50517 VHS CX 10/15-60 50510 VHS CX 10/35-80 50511 VHS CX 10/55-100

60 80 100

M8x60 M8x80 M8x100

10 10 10

50 50 50

15 35 55

25 25 25

T40 T40 T40

15 35 55

25 25 25

T40 T40 T40

Code

VHS CX with Torx bit 8.8 screw

60517 VHS CX A2 10/15-60 60 60510 VHS CX A2 1 0/35-80 80 60511 VHS CX A2 1 0/55-100 100

M8x60 M8x80 M8x100

10 10 10

50 50 50

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner

Installation sequence

Installation data

VHS Anchor Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness

Scr Ccr Smin Cmin hmin

M8 240 120 120 60 100

mm mm mm mm mm

Permissible loads - applications in concrete C20/25 VHS AF - VHS Z - VHS AE 10 - M8 VHS CX cl. 8.8 10 - M8 VHS CX INOX A2 10 - M8 - - -

1 daN ≃1 kg 200 230 230

daN daN daN

Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.

164

Solid brick


through-setting heawy duty anchors

Vorpa Security Anchor TOP

Special permanent temper-proof fixings as protection against burglary and thievery

Non-cracked concrete

Natural stone

Solid brick

Products group TOP AF with zincplated steel shear nut AF

Suitable for • Non-cracked concrete • Natural stone • Solid brick

TOP AE with A2 stainless steel shear nut

To fix • Window and door frames • Gates • Railings • Iron bars • Traffic signals • Garden fittings

Examples of applications

Product information Characteristics • Through steel anchor composed of anti-rotation cold formed body and expansion conical nut with shear nut. Benefits • Anti-rotation during the installation procedure • Possibility of pre-setting applications and through-setting applications • Smooth expansion thanks to the three sectors body • Shear nut

Installation • Through-setting anchor Suggestion for use • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

Installation sequence

TOP AF

TOP AE

165


through-setting heawy duty anchors

Vorpa Security Anchor TOP

Special permanent temper-proof fixings as protection against burglary and thievery

Non-cracked concrete

Natural stone

Solid brick

Technical data TOP AF sleeve anchor is a through fixing, thus ensuring fast and simple installation. Ideal for many security applications in a wide variety of base materials. The unique AF drive permanent nut offers an accurate torque controlled security fixing which can be re-torqued if necessary.

TOP AF with zincplated steel shear nut

Code

Description

7578 TOP AF 12/6-55 7562 TOP AF 12/25-75 7563 TOP AF 12/45-95

Lt mm

screws d x Lb mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Driver Socket Ch

55 75 95

M8x55 M8x75 M8x95

12 12 12

55 55 55

6 25 45

15 15 15

AF M8 AF M8 AF M8

AF DRIVER SOCKET AND AF PERMANENT NUT

Code

Description

72589 72592 72590 72591

AF M8 AF M10 DADO AF M8 DADO AF M10

internal thread

for nut

for anchor TOP AF

art. 72590 art. 72591

art. 7578/7562/7563 -

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner

M8 M10

Security anchors with shear nut for final fixing of windows, iron fences, gates, etc. Suitable for every compact building materials. Exceeding a torque of 19 Nm the hexagonal head takes off giving no chance to slip off the fixing. Hexagonal head and washer are made in A2 Stainless Steel.

TOP AE with A2 stainless steel shear nut

Code

Description

578 TOP AE 12/6-55 562 TOP AE 12/25-75 563 TOP AE 12/45-100

Lt mm

screws d x Lb mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Ch

55 75 100

M8x55 M8x75 M8x100

12 12 12

55 55 55

6 25 45

* * *

15 15 15

* Approximate breaking torque at 19Nm Installation data

Top Anchor Critical axial spacing Critical edge distance Minimum axial spacing Minimum edge distance Minimum structural thickness

Scr Ccr Smin Cmin hmin

M8 135 75 90 70 135

mm mm mm mm mm

Permissible loads - applications in concrete C20/25 TOP AE 12 - M8 TOP AF 12 - M8

1 daN ≃1 kg 400 400

daN daN

166

- Always respect the installation parameters - In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) - The table shows the permissible loads for tension, shear and combined tension and shear loads.


pre-setting heavy duty anchors

Vorpa Security Anchor VH AE Nylon plugs

Solid brick

Perforated bricks

Products group VH AE with steel screw and A2 stainless steel shear nut

To fix • Window and door frames • Gates • Railings • Iron bars • Traffic signals • Garden fittings

Suitable for • Solid brick • Perforated brick

Product information Characteristics • Nylon plug with diagonal slots

Installation • Through-setting anchor

Benefits • Anti-rotation system during the installation • Possibility of pre-setting applications and through-setting applications • Smooth expansion thanks to the slots on the body • Shear nut

Suggestion for use • Choose the most suitable accessory in relation to the application to carry out • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

Installation sequence

Technical data Security anchors with shear nut for final fixing of windows, iron fences, gates, etc. Suitable for every compact building materials. Exceending a torque of 19 Nm the exagonal head takes off giving no change to slip off the fixing. Hexagonal head and washer are made in A2 Stainless Steel.

Code

Description

588 VH AE 558 VH AE

8/5-75 8/25-95

Lt mm

screw d x Lb mm

d0 mm

h1 mm

tfix max mm

Tinst Nm

Ch

70 70

M8x75 M8x95

12 12

75 75

5 25

* *

13 13

* Approximate breaking torque at 19Nm Installation data Permissible loads - applications in concrete C20/25 SAFETY ANCHOR VH - - -

1 daN ≃1 kg

daN

150

Always respect the installation parameters In case of axial spacings or edge distances are inferior than the critical ones, it is recommended to reduce the application load (please refer to the general technical guide) The table shows the permissible loads for tension, shear and combined tension and shear loads.

167

Screw length calculation: Lv = Lt + tfix h1 = Min. hole depth Lt = Anchor length Lv = Screw length d0 = Hole diameter d = Screw diameter tfix = Fixture thickness tinst = Torque Ch = Spanner


through-setting heawy duty anchors

Vorpa Wire rope clip Accessories

Product group Suitable for • Wire ropes • Cables • Tie rods • Ropes

Suitable to fix • Radio systems cables • TV systems cables • Tie rods for orchards • Wire clotheslines • Tensioning cables

Characteristics • Forged wire rope clip Examples of installation

Examples of application

Correct method of fitting Wire Rope Grips

Incorrect method of fitting Wire Rope Grips

Technical data Code

1520 1521 1522 1523 1524 * * * * * * * * * * * * *

ØR mm

Ø R”

A mm

B mm

C mm

D mm

E mm

F mm

I mm

L mm

S mm

T mm

2-3 4-5 6 8 10 11 12 14 16 18 20 22 24-25 26-28 30-32 36-38 42-45 48-50

1/8 3/16 1/4 5/16 3/8 7/16 1/2 9/16 5/8 11/16 3/4 7/8 1 1.1/8 1.1/4 1.1/2 1.3/4 2

21 25 30 33 38 40 43 46 53 59 60 64 70 80 92 95 115 116

12 18 19 20 22 22,5 25 27 31 33 34 34 40 43 45 51 58 59

9 9 10 10,5 11 13 13 17 18 20 22 23 24 30 34 39 43 46

M4 M5 M6 M6 M8 M8 M10 M10 M10 M12 M12 M12 M12 M14 M16 M16 M20 M20

5 5 6 6 6 6 6 7,5 8 8 9 9,5 10 12 14 16 16 16

12 14 19 22 22 23 30 30 32 38 38 42 46 50 70 75 83 83

9 11 15 16 19 21 23 25 28 30 33 37 40 42 49 57 70 70

20 25 33 35 43 43 55 55 63 78 78 80 88 97 130 135 158 178

1,25 2,46 4,24 4,24 10,2 10,2 20,11 20,11 20,11 34,43 34,43 34,43 34,43 54,77 85,14 85,14 167,2 167,2

3 3 4 4 4 4 5 5 5 5 5 6 6 7 8 8 10 10

S = Torque (with 0,10 safety factor included) T = Nr. clips to use

* Available on request

168

R

L

E

F I A

C D B


heavy duty anchors

Vorpa Wire rope clip (italian TELECOM-ENEL standard) Galvanized forged clamp for rope, cables and tie rods with serial number product group Suitable for • wire ropes • cables • rods

Wire rope clip

To fix • steel ropes • plant cables • rods • tension ropes and cables • ropes ENEL number 263202 • ropes serial number TELECOM 02076-8

Caution Before starting to operate, perform the correspondence check functional and performance of the clamp installed to confirm its suitability

examples of applications and instructions Installation mode It is advisable to apply the clamps at a distance from one another not less than 22 mm

Tz

Correct installation

incorrect installation

INTERVENTION FREQUENCY QUARTERLY ANNUAL X X X X X

CHECK Visual conditions Tightening torque Deformation Usury Conservation status

Selection criteria • The clips must be chosen according to the cable diameter • The clips must be used only for wire ropes • Permissible temperature between -20°C e + 80°C • Periodically check the functionality and efficiency of the clamp • The tightening torque must be transmitted with a tightening torque wrench • The clamp works efficiently until its geometric and physical characteristics and the applied tightening torque remain unchanged

technical data

Incorrect use In order not to compromise the safety and functionality of the product and not cause serious situations of danger for the safety of people or things • DO NOT use the clamps in situations contrary to national safety or accident laws • DO NOT combine the clamps with non-compliant accessories • modifying them in the structure or in the form • DO NOT use the clamps in equipment intended for the transport or lifting of persons or animals • DO NOT exceed the loads indicated in the table • DO NOT ignore the instructions for use regarding the correct selection or arrangement of the device to which the clamps will be connected with • DO NOT use the wire rope clips in tension with equipment that can change its own static configuration, the barycentre or the chemical state • DO NOT use the clips to join together two pieces of rope by welding it with metal parts or by intervening with welding fillings or using it as a mass for welding machines • DO NOT use the clips with plastic covered wire ropes, or for the construction of buttonholes to be used in lifting, do not use the clips connecting them to equipment of size, temperature point of coupling and shape not suitable for its characteristics, do not use them in situations of failure or incorrect maintenance Limitations DO NOT use the clamps • when the tightening torque is higher than indicated • as structural failures can occur on the U-bolt • when a smaller number of terminals is applied to how much indicated • at temperatures other than those indicated • when the force guideline does not extend along the main axis of the rope

1

1 Ø8-Ø6 Ø6-Ø4

C

B

2 3

D

A

H

3

G

2

F E

Code

89002 ENEL 263202 Ø4-Ø6

89001 TELECOM 02076-8 Ø6-Ø8

A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) G (mm) H (mm) Peso (gr) Tinst (Nm) N Tz

M6 31 17 16,8 30 16 14 10 35 4,24 3 -

M8 42 25 20 37 22 20 13 70 10 3 240

N = min. numbers of clips to be installed Tinst = max tightening torque to be used

169


heavy duty anchors

Vorpa Steel buckle accessories

Products group

Eye and eye turn buckle

Hook and eye buckle

Suitable for • Wire ropes • Cables • Tie rods • Ropes

Characteristics • Forged turn buckle

Suitable to fix • Radio systems cables • TV systems cables • Tie rods for orchards • Wire clotheslines • Tensioning cables

Technical data Code

1260 1261 1262 1263 * 1264 * * * * * * * * * * *

D mm

A mm

B mm

C mm

E mm

F mm

G mm

L mm

Max load kg

Coeff.

M5 M6 M8 M10 M11 M12 M14 M16 M18 M20 M22 M24 M27 M30 M33 M36 M39

35 44 52 62 68 70 85 90 98 105 118 130 135 135 148 158 170

8 11 11 14 15 16 18 23,5 25 26 28 28 31 31 36 42 49

16 19 22 28 33 33 36 48 51 57 60 65 71 71 88 94 104

9 10 13 14 18 18 20 22 27 27 28 30 49 56 56 55 58

49 59,5 71 90 90 91,5 113 132 135,5 156,5 160 179,5 188,5 188,5 201 230 238

7 8 10 12 15 15 17 19 20 20 23 25 31 31 34 44 44

80 90 110 125 120 140 170 190 200 220 240 260 300 310 310 295 330

25 45 75 115 140 150 210 340 450 650 900 1200 1400 1500 1750 2000 2250

4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

Coeff. = Safety factor to be applied

* on request

L G

B C E D

A F

L B C E D

L

A F

G

B C E D

Code

1250 1251 1252 1253 * 1254 * * * * * * * * * * * * *

D mm

A mm

B mm

C mm

E mm

F mm

L mm

Max load kg

Coeff.

M5 M6 M8 M10 M11 M12 M14 M16 M18 M20 M22 M24 M27 M30 M33 M36 M39 M42 M45

35 44 52 62 68 70 85 90 98 105 118 130 135 135 148 158 170 170 170

8 11 11 14 15 16 18 23,5 25 26 28 28 31 31 36 38 42 50 50

16 19 22 28 33 33 36 48 51 57 60 65 71 71 88 94 104 110 110

9 10 13 14 18 18 20 22 27 27 28 30 49 56 56 55 58 66 66

49 59,5 71 90 90 91,5 113 132 135,5 156,5 160 179,5 188,5 188,5 201 230 238 245 245

80 90 110 125 120 140 170 190 200 220 240 260 300 310 310 295 330 340 340

100 150 300 470 580 650 800 1250 1500 1800 2250 2800 3500 4000 4500 5000 6000 7000 8000

4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

170

A F

L B C E D

A F


heavy duty anchors

Vorpa Accessories fixing accessories Products group

Pressed threaded eye with nut and washer

Pressed threaded eye

A2 stainless steel pressed threaded eye

• Suitable for each applications with chemical anchors and mechanical anchors

• Ideal for various applications • Available also with nut and washer

Technical data Pressed threaded zincplated eye

Code

* 994 * * 995 * 996 * 997 * * 998 * 999

ØDxB thread x length

L thread

A length

E

M5x45 M5x50 M6x45 M6x55 M6x60 M8x57 M8x65 M10x68 M10x81 M10x101 M12x74 M12x98 M14x93 M16x100

40 48 40 50 55 52 60 60 73 93 66 90 85 95

60.7 65.7 64.6 74.6 79.6 78.6 86.7 94.1 107.1 127.1 106.3 130.3 127.1 145.3

52.7 57.7 54.6 64.6 69.6 67.4 75.4 80.6 93.6 113.6 89.5 113.5 109.4 122.1

15.3/16.7 15.3/16.7 18.3/19.7 18.3/19.7 18.3/19.7 21.8/23.2 21.8/23.2 26.0/28.0 26.0/28.0 26.0/28.0 32.5/34.5 32.5/34.5 34.5/36.5 44.8/47.2

G min/max

F min/max

S min/max

8.05/8.55 3.20/3.80 8.05/8.55 3.20/3.80 9.75/10.25 3.90/4.50 9.75/10.25 3.90/4.50 9.75/10.25 3.90/4.50 10.75/11.25 4.90/5.50 11.55/12.05 4.90/5.50 14.25/14.75 6.15/6.85 14.25/14.75 6.15/6.85 14.25/14.75 6.15/6.85 16.75/17.25 8.15/8.85 16.75/17.25 8.15/8.85 17.75/18.25 8.30/9.10 22.70/23.30 12.10/12.90

Max load kg

L G

ØD

480

A

E

B

696

F 1360

S

2020 2966

Racommended safety factor not less than 3

4290 5680

* on request A2 stainless steel pressed threaded eye

Code

995i * * * * 996i * 997i * 998i

ØDxB thread x length

L thread

A length

E

G min/max

F min/max

S min/max

M6x55.5 M6x60.5 M6x65.5 M8x61.5 M8x66.5 M8x71.5 M10x67.0 M10x80.0 M12x73.5 M12x97.5

50 55 60 55 60 65 60 73 66 90

75.0 80.0 85.0 83.0 88.0 93.0 97.0 11.0 107.0 131.0

65.0 70.0 75.0 72.0 77.0 82.0 81.5 94.5 89.5 113.5

19.2/20.8 19.2/20.8 19.2/20.8 21.2/22.8 21.2/22.8 21.2/22.8 30.0/32.0 30.0/32.0 34.0/36.0 34.0/36.0

9.7/10.3 9.7/10.3 9.7/10.3 10.7/11.3 10.7/11.3 10.7/11.3 13.6/14.4 13.6/14.4 15.6/16.4 15.6/16.4

5.2/5.8 5.2/5.8 5.2/5.8 6.0/6.6 6.0/6.6 6.0/6.6 8.2/9.0 8.2/9.0 8.6/9.4 8.6/9.4

* on request

171

Max load kg

2100

2915 4540 7020

Racommended safety factor not less than 3


heavy duty anchors

Vorpa Accessories fixing accessories Products group

Pressed threaded hook

A2 stainless steel pressed threaded hook

Pressed threaded hook with nut and washer

Technical data Pressed threaded zincplated hook

ØD

Code

L thread

A length

B

E

H

ØI

Max load kg

H E

ØI

ØD L

* 1070 * * 1010 * 1011 * * 1012 * 1013 *

M5 M5 M6 M6 M6 M8 M8 M8 M10 M10 M12 M12 M14

40 48 40 50 55 52 60 80 60 73 66 90 82

62.0 71.5 67.0 77.0 82.0 90.0 98.0 118.0 103.5 116.5 122.0 146.0 144.0

53.6 63.0 55.5 65.5 70.5 75.5 83.5 103.5 87.5 100.5 101.5 125.5 120.5

17.5 17.5 22.5 22.5 22.5 30.0 30.0 30.0 36.0 36.0 47.0 47.0 48.0

6.0 6.0 8.0 8.0 8.0 10.0 10.0 10.0 12.5 12.5 16.0 16.0 16.0

7.5 7.5 9.5 9.5 9.5 11.0 11.0 11.0 14.0 14.0 18.0 18.0 17.0

173

A

B

241

387 547 1057

Racommended safety factor not less than 3

1342

* on request A2 stainless steel pressed threaded hook

Code

1010i * * 1011i * 1012i * 1013i

ØD

L thread

A length

B

E

H

ØI

M6 M6 M8 M8 M10 M10 M12 M12

50 55 55 60 60 73 66 90

77.0 82.0 93.0 98.0 103.5 116.5 122.0 146.0

65.5 70.5 78.5 83.5 87.5 100.5 101.5 125.5

22.5 22.5 30.0 30.0 36.0 36.0 47.0 47.0

8.0 8.0 10.0 10.0 12.5 12.5 16.0 16.0

9.5 9.5 11.0 11.0 14.0 14.0 18.0 18.0

Max load kg

241 387 547

Racommended safety factor not less than 3

1057

* on request Code

1054

Description

GF 10/95

threaa

thread length mm

Ø hole

M10

75

12

Gancio GF threaded square hook

172


Universal and frame fixings


universal and frame fixings

Vorpa THERMOISO PLUS

innovative anchorage system for masonry coated by heatinsulating panels and insulation materials.

Concrete

Natural stone

Solid brick

Perforated brick

Hollow brick

Cellular concrete

Aerated concrete

Products group Suitable for • concrete • natural stone • solid brick • perforated brick • hollow brick • cellular concrete • aerated concrete

To fix • blinds • hinges • rain descendants • shelters • curtains

Product information Benefits • Innovative anchorage system for masonry coated by heatinsulating panels and insulation materials. • High mechanical strength even on panels lined with panels high thickness insulators. • Elimination of the so-called “thermal bridge” internal-external, ie prevents thermal dispersions in edifices, condensates and molds. • Thermoiso Plus is universal, it can be used on any type of masonry, both full and perforated. • Quick, practical and intuitive application does not require any particulars equipment, only one drill-machine, a drill bit and a chemical cartridge • Drilling diameter reduced compared to conventional methodologies. • The thermoiso system is convenient because it offers a solution to ideal fixation at a low cost. it is advisable to use an adhesive sealant on the back of the support ring to prevent any water infiltration in the panel.

Fixing system consisting of: 2mm thick wrought iron sheet structure and punched M12 and M16 threaded rod, welded to provide extra load resistance. Zinc coating electrolytic for corrosion protection. The system allows applications on insulated walls with a thickness of 60 mm to 145 mm (160 mm on compact walls). It is also possible to use it on larger coats reducing the shear load; polyamide sleeve specially designed to accommodate M8, M10 or M12 accessories and Ø 6 to Ø12 wood screws. Avoids the contact of the threaded with the bearing structure in metal, eliminating the thermal bridge between the interior and exterior of the building. The support ring gives a pleasant aesthetic finish and allows perfect alignment to the wall; special perforated sleeve for anchoring with injection resins on perforated walls (on compact masonry is not required

Examples of applications

Hinges and general frames

Roofs and canopies

Rainwater pipes

Wall parabolic dishes

External air conditioners

Wall heaters

174


universal and frame fixings

Vorpa THERMOISO PLUS

innovative anchorage system for masonry coated by heatinsulating panels and insulation materials.

Concrete

Natural stone

Solid brick

Perforated brick

Hollow brick

Cellular concrete

Aerated concrete

Installation sequence Application sequence of Thermoiso Plus on hollow materials with perforated sleeve 3)

Max 145 mm Max 145 mm

1)

3)

1) 2) 2)

Application Max sequence of Thermoiso Plus on solid materials

3) 1)

160 mm Max 160 mm

3)

1) 2) 2)

Technical data

A B

Code

C

Description

A) Total length mm

B) Max insulation panel thickness mm

C) Thread length mm

Ø Hole on hollow brick mm

Ø Hole on solid brick mm

58742 Thermoiso Plus 6 58743 Thermoiso Plus 8

217 217

140 140

80 80

16 16

16 16

58740 Thermoiso Plus M10 58741 Thermoiso Plus M12

240 240

145 (160)* 145 (160)*

90 90

20 20

20 20

* On solid brick, the threaded bar can be inserted into the supporting masonry with a minimum depth of 75 mm. so you can consider a max thickness of insulation panel of 160 mm.

art. 58742 for wood screws Ø6 - Ø7

art. 58740 for metric screws M10 and wood screws Ø10

art. 58743 for wood screws Ø8 - M8

art. 58741 for metric screws M12 and wood screws Ø12

Accessories Hinges

Firm shutters

Threaded screw

Threaded bar

Wood screws

Double thread screw

M10 - M12

Ø6 - Ø7 - Ø8

M8 - M10 - M12

M8 - M10 - M12

Ø7 - Ø8 - Ø10 - Ø12

Ø6 - Ø8 - Ø10 - Ø12

175


universal and frame fixings

Vorpa THERMOISO PLUS

innovative anchorage system for masonry coated by heatinsulating panels and insulation materials.

Concrete

Natural stone

Solid brick

Accessories

Perforated sleeves CVX

Code

Adhesive sealant

Description

Content

ml 58732 Perforated sleeve CVX Ø16x85 per Thermoiso Plus 6 e 8 58731 Perforated sleeve CVX Ø20x100 per Thermoiso Plus M10 e M8 23001 Adhesive sealant MS-POLYMER SiMP•SEAL 55

290

Chemical anchor CV.PSF

Code

Description

1124 CV.PSF 300 1002P CV.PSF 410 1005 Mixer

Content

Mixer

ml 300 410

n° 1 1

Suitable for

Weigth kg

CV.PSF 300

0,7

CV.PSF 410

1

Manual caulking gun

Code

Description

1009 Metal caulking gun 300 ml professional 2,5 kN 1101 Metal caulking gun 410 ml professional 2,5 kN

Dust cleaning manual pump

Code

Cleaning brush

Description

1072 Dust cleaning manual pump

length mm. 225

1049 Cleaning brush holes Ø 10 - Ø 20 1059 Cleaning brush holes Ø 20 - Ø 30

brush length mm 100 brush length mm 100

176

Perforated brick

Hollow brick

Cellular concrete

Aerated concrete


universal and frame fixings

Vorpa THERMOISO PLUS

innovative anchorage system for masonry coated by heatinsulating panels and insulation materials.

Concrete

Natural stone

Solid brick

Perforated brick

Hollow brick

Cellular concrete

Aerated concrete

Thermoiso Plus - anchorage system for masonry coated by heat-insulating panels and insulated materials Loads on concrete and solid material Shear 2)

Thermoiso Plus 6-Ø16 - Wood screws Ø 5x50 Thermoiso Plus 6-Ø16 - Wood screws Ø 6x60 Thermoiso Plus 6-Ø16 - Wood screws Ø 7x85 Thermoiso Plus 8-Ø16 - Hexag. head screw Ø 8x80 Thermoiso Plus M10-Ø20 - Metric hexag. screw M10x803) Thermoiso Plus M12-Ø20 - Metric hexag. screw M12x803)

Pull out 1)

Tfix 50 mm

Tfix 60 mm

Tfix 70 mm

Tfix 80 mm

Tfix 90 mm

Tfix 100 mm

Tfix 110 mm

Tfix 120 mm

Tfix 130 mm

Tfix 140 mm

Tfix 150 mm

Tamm

Vamm

Vamm

Vamm

Vamm

Vamm

Vamm

Vamm

Vamm

Vamm

Vamm

Vamm

Smin

Cmin

daN

daN

daN

daN

daN

daN

daN

daN

daN

daN

daN

daN

mm

mm

60

56

53

50

48

46

44

42

28

25

20

80

80

90

80

70

60

40

50

45

40

35

30

25

80

80

165

155

145

135

125

117

110

105

95

80

65

100

100

Minimum Edge axial distance spacing

20 50 80 90 90 90

1daN ≈ 1Kg

Tfix ≈ insulation panel thickness

Load perforated brick (Poroton) Shear 2)

Thermoiso Plus 6-Ø16 - Wood screws Ø 5x50 Thermoiso Plus 6-Ø16 - Wood screws Ø 6x60 Thermoiso Plus 6-Ø16 - Wood screws Ø 7x85 Thermoiso Plus 8-Ø16 - Hexag. head screw Ø 8x70 Thermoiso Plus M10-Ø20 - Metric hexag. screw M10x803) Thermoiso Plus M20-Ø20 - Metric hexag. screw M12x803) 1daN ≈ 1Kg 1) Tensile

Pull out 1)

Tfix 50 mm

Tfix 60 mm

Tfix 70 mm

Tfix 80 mm

Tfix 90 mm

Tfix 100 mm

Tfix 110 mm

Tfix 120 mm

Tfix 130 mm

Tfix 140 mm

Tfix 150 mm

Tamm

Vamm

Vamm

Vamm

Vamm

Vamm

Vamm

Vamm

Vamm

Vamm

Vamm

Vamm

Smin

Cmin

daN

daN

daN

daN

daN

daN

daN

daN

daN

daN

daN

daN

mm

mm

60

56

53

50

48

46

44

42

28

25

20

80

80

90

80

70

60

40

50

45

40

35

30

25

80

80

120

112

105

97

90

85

80

75

70

62

45

100

100

20 50 65 75 60 60 Tfix ≈ insulation panel thickness

loads include an appropriate safety coefficient Test reports available

2) Cut-off

loads are considered as a function of a maximum displacement of 3mm. For more information on higher displacement, contact Vorpa Technical Support. 3) Data

Minimum Edge axial distance spacing

refer to tests performed with UNi metric screws 5739 class 8.8 with insertion depth inside the 60 mm thermal insulation sleeve.

177


universal and frame fixings

Vorpa THERMOISO PLUS

innovative anchorage system for masonry coated by heat-insulating panels and insulation materials.

EXTRACT FROM TEST REPORT N. 337967 OF 25/11/2016 Calculation of thermal transmittance for thermal insulation coat (Ethics) bymeans of the Finite Element Method, in accordance with UN in EN 6946: 2008 and UN and EN isO 10211: 2008

[°C]

[°C]

20

20

19

19

18

18

17

17

16

16

15

15

14

14

13

13

12

12

11

11

10

10

9

9

8

8

7

7

6

6

5

5

4

4

3

3

2

2

1

1

0

0

[°C] 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

The exact thermal transmittance value present at the anchorage system, in a masonry plastered internally and externally with a thickness of 15 and 5 mm respectively, with a total thickness of 330 mm (made of 250 mm thick brick elements and with 60 mm of thick external insulation panels) and thermal conductivity 0.034 W / (m · K); It results to be

X = 0,012 W/K 178


universal and frame fixings

Safety witholding hooks for tiles and ceramic slabs mounted in façade with adhesive The glued façade is a system that makes it possible to get good-looking results and less recurring maintenance than other equivalent systems. This type of covering uses adhesive to attach ceramic slabs directly onto the plaster of the building exterior. However, to ensure the laying of slabs over 30cm it is necessary to adopt an additional safety devise against detachment of the adhesive due to tensions arising from structural adjustments, stretching and extension to thermal excursions, earthquake shakings, etc.

•plug

•plug with screw

The concealed Vorpa Click-Up system is a patented device that ensures the connection of the ceramic slab to the wall by an invisible mechanical hook inserted in the slab itself through an engrave before laying. After having covered the slab with glue and installed it, the hook is subsequently secured to the wall by a plug.

•wall

The Vorpa Click-Up system provides pull-out load over 350kg* for each application point stated by specific laboratory tests. This allows great safety in case of detachment of the glue between wall and slab together with fast and practical installation.

(*Click-Up M-type on 11mm porcelain tiles with adhesive).

•slab

•engrave

Vorpa Click-Up safety hooks are made of 0,5mm AISI304 stainless steel in four different sizes according to thickness of slabs (minimum 6mm). They are supplied ready for assembly to back side slabs once made the incision by Click-Cut grooving toll.

•Click-Up

•adhesive

D

TE N E T A P

179


universal and frame fixings

Vorpa CLICK-UP

Safety witholding hooks for tiles and ceramics mounted in façade with adhesive Tile length

Pieces per tile (A)

10 ≤ 60 cm 60 ≤ 150 cm 150 ≤ 240 cm 240 ≤ 320 cm

Click-Up recommended load (B)

daN

Size S (small)

Size M (medium)

Size L (large)

Size XL (extra large)

45 daN

55 daN

60 daN

65 daN

1 2 3 4

Pieces per box

500

1 daN=1kg

(A) The number of hooks is indicative. However, it is recommended being the designer to identify the number of hooks for tile/slab according to dimensions, base material, local regulations and environment conditions. (B) Recommended loads are stated applying a safety factor equal to 4.

Art. 4086

CLICK-UP serie S (small) Click-Up size S (small)

Art. 4087

CLICK-UP Click-Upserie sizeMM(medium) (medium)

30

30

0,5

0,5

CLICK-UP

CLICK-UP

CLICK-UP

CLICK-UP

9

9

9

9

9

9 8,5

8,5

100

8,5 8,5

8,5

35°

13

r1

5

9 8,5

8,5

8,5

8,5

8,5 8,5

8,5

13

5,6

8,5 8,5

8,5

8,5

9 8,5

99

8,5

101

30

0,5

8,5

r1

Art. 4089

CLICK-UP Click-Up serie size XL XL (extra-large) (extra large)

30

0,5

35°

Art. 4088

CLICK-UP seriesize L (large) Click-Up L (large)

97

Tested by

35°

35°

13

8,5

13

r1

r1

9

7,2

Installation sequence 1

Engraving slab by grooving tol Click-Cut 2

Insert the hook in the engrave

Slab back side 3

4

Laying the glue on the slab and wall

5

Fix the hook with plug and screw

Art 4099 Click-cut grooving tool

Slab front side

Work completed

180

Install the slab to the wall with glue


universal and frame fixings

Vorpa CLICK-UP

Safety witholding hooks for tiles and ceramics mounted in façade with adhesive accessories

Threaded bar for application on masonry coated with insulating panels

Code

Description

Internal thread

Max thickness of insulating panel mm

Min. embedment depth on masonry mm

Ø hole on hollow masonry mm

Ø hole on solid masonry mm

M6x14 M6x14 M6x14

80 100 120

80 80 80

16 16 16

14 14 14

91038 Threaded bar Ø12x160 91075 Threaded bar Ø12x180 91042 Threaded bar Ø12x200 Other sizes on request

Perforated plastic sleeve CVX to be used on hollow masonry

Code

Description

58732 Perforated sleeve CVX Ø16x85

Ø hole on hollow masonry

mm Ø16

Chemical anchor CV.PSF

Code

Description

1124 CV.PSF 300 1002P CV.PSF 410 1005 Mixer

Content

MIxer

ml 300 410

n° 1 1

Examples of installation Insulating panels on solid masonry

Insulating panels on hollow masonry

181


universal and frame fixings

Vorpa CLICK-CUT grooving tool

B D A C

A

Wing nut to adjust the slab thickness and block.

B

Wing nut to adjust the cutting inclination, the right inclination of Click-Cut flute Device for engraving slabs is 55° for each size Click-Up hook.

C

Flange to adjust the cutting position.

D

Wing nut to adjust the cutting depth.

182


universal and frame fixings

Vorpa VK

4 segments nylon plug

Concrete

Solid brick

Perforated brick

Hollow brick

Plasterboard

Light construction materials

Products group VK

VK V with chipboard screw

Suitable for • Concrete • Solid brick • Perforated brick • Hollow brick • Plasterboard • Light construction materials • Perforated cement

To fix • Light carpentry • Curtains slide guides • Bath accessories • Lamps, paintings • Post boxes • Satellite dishes • Wall cupboards

VK C with pan head screw

VK T with hexagonal head screw and washer

Examples of applications

Product information Characteristics • 4 way expansion form nylon plug

Installation • To be mounted aligned the wall

Benefits • Easy and quick fixings thanks to the four segments of the body • Anti-rotation lugs stop the plug rotating in the drill hole • The fixing’s collar prevents it slipping into the drilled hole • Nylon safety and reliability • Temperature resistant from -40°C to +80°C • To be used with wood and clipboard screws

Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation

183

Perforated cement


universal and frame fixings

Vorpa VK

4 segments nylon plug

Concrete

Solid brick

Perforated brick

Hollow brick

Plasterboard

Light construction materials

Installation sequence Solid materials

Hollow materials

Technical data

VK nylon plug

Code

4720 4721 4722 4723 4725 4726

Description

d0 mm

Lt mm

h1 mm

h1 mm

VK 5 VK 6 VK 8 VK 10 VK 12 VK 14

5 6 8 10 12 14

25 30 40 50 60 70

35 45 55 65 80 90

3÷4 4÷5 4,5÷6 6÷8 8÷10 10÷12

Lt h1 d0 Tfix Øv Lv

= Plug length = Min. hole depth = Hole diameter = Fixture thickness = Screw diameter = Screw length

Screw length Lv = Lt + Tfix + Øv

VK V with chipboard screw

Code

4735 4736 4737 4738

Description

VK V VK V VK V VK V

5 6 8 10

d0 x Lt mm

h1 mm

Tfix mm

Øv x Lv mm

5 x 25 6 x 30 8 x 40 10 x 50

35 45 55 65

5 10 10 10

3,5 x 30 4,5 x 40 5 x 50 6 x 60

184

Perforated cement


universal and frame fixings

Vorpa VK

4 segments nylon plug

Concrete

Solid brick

Perforated brick

Hollow brick

Plasterboard

Light construction materials

Technical data

VK C with pan head screw

Code

Description

d0 x Lt mm

h1 mm

Tfix mm

Øv x Lv mm

4720C 4721C 4722C

VK C 5 VK C 6 VK C 8

5 x 25 6 x 30 8 x 40

35 45 55

5 10 10

3,5 x 30 4,2 x 40 4,8 x 50

VK T with hexagonal head screw and washer

Code

Description

4722T 4723T 4725T 4726T

VK T VK T VK T VK T

8 10 12 14

d0 x Lt mm

h1 mm

Tfix mm

Øv x Lv mm

Ch mm

8 x 40 10 x 50 12 x 60 14 x 70

55 65 80 90

5 10 10 5

6 x 45 7 x 60 8 x 70 10 x 80

10 12 13 17

Installation data Tensile resistance in daN with wood screws Ø screws (mm) Concrete C20/25 Solid brick** Double brick UNI with plaster** Gasbeto > G4

1 daN ≃1 kg VK 5 4 180 150 40

VK 6 5 280 150 80 50

VK 8 6 300 200 80 50

VK 10 8 800 400 150 110

VK 12 10 1200 460 130

VK 14 12 2400 -200

ATTENTION: An appropriate safety factor = 5 should be applied on these values. As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.

185

Lt h1 d0 Tfix Ø v Lv Ch

= Plug length = Min. hole depth = Hole diameter = Fixture thickness = Screw diameter = Screw length = Spanner

Perforated cement


universal and frame fixings

Vorpa TV Z

Universal nylon plug

Concrete

Solid brick

Perforated brick

Hollow brick

Aerated concrete

Perforated cement

Products group TV Z

TV Z V with chipboard screw

Suitable for • Concrete • Solid brick • Perforated brick • Hollow brick • Aerated concrete • Perforated cement

TV Z V A2 with stainless steel chipboard screw

To fix • Window and door frames • Light structural works • Wooden substrucrures • Handrail • Light carpentry • Curtains slide guides • Bath accessories • Lamps, paintings • Post boxes • Satellite dishes • Wall cupboards

Installation sequence On compact materials

Make a drill hole with a hammer drill

Clean the hole

Place the fixture and then insert the anchor into the hole

Put the anchor by hammering softly on the screw head until the fixture stops the nylon plug

Make sure that the fixture is supported by the anchor (nylon plug and screw)

Clean the hole

Place the fixture and then insert the anchor into the hole

Put the anchor by hammering softly on the screw head until the fixture stops the nylon plug

Sent the screw by screw driver or by hand. Make sure that the fixture is supported by the anchor (nylon plug and screw)

Hollow materials

Make a drill hole with a hammer drill

Product information Characteristics • Multi-purpose anchor, suitable for all base materials. Concrete and solid masonry materials, by fully radial expansion perforated masonry, by multiple radial expansion hollow masonry, by knotting

Benefits • Multiple radial expansion behaviour on perforated masonry • Knotting behaviour on hollow masonry • Temperature resistant from -40°C to + 80°C

Benefits • Special wings to avoid turning The special anti-rotation wings on the nylon sleeve provides easy and safe installation on all types of material, avoiding any rotation of the nylon sleeve while the screw is installed • No waiting time before loading • Ideal for fixing of facade, frames and general fastenings • Fully radial expansion behaviour on concrete and solid masonry

Installation • To be mounted aligned the wall Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation

186


universal and frame fixings

Vorpa TV Z

Universal nylon plug

Concrete

Solid brick

Perforated brick

Hollow brick

Aerated concrete

Perforated cement

Technical data

TV Z LUNGO

Code

4739 4740 4741 4742

Description

hmin mm

d0 x Lt mm

screw mm

h1 mm

Tfix mm

hef mm

df mm

TV Z 6x32 TV Z 6x45 TV Z 8x42 TV Z 8x52

60 60 70 70

6x32 6x45 8x42 8x52

4,5 4,5 5,0 5,0

45 55 60 65

2 12 3 13

30 30 39 39

7 7 9 9

TVZ with chipboard screw

Code

4743 4744 4745 4746

Description

hmin mm

d0 x Lt mm

Øv x Lv mm

h1 mm

Tfix mm

hef mm

df mm

TV Z V TV Z V TV Z V TV Z V

60 60 70 70

6x32 6x45 8x42 8x52

4,5x40 4,5x50 5,0x50 5,0x60

45 55 60 65

2 12 3 13

30 30 39 39

7 7 9 9

6x32 6x45 8x42 8x52

TVZ V A2 with stainless steel chipboard screw

Code

4747 4748 4749 4750

Description

hmin mm

d0 x Lt mm

Øv x Lv mm

h1 mm

Tfix mm

hef mm

df mm

TV Z V TV Z V TV Z V TV Z V

60 60 70 70

6x32 6x45 8x42 8x52

4,5x40 4,5x50 5,0x50 5,0x60

45 55 60 65

2 12 3 13

30 30 39 39

7 7 9 9

A2 6x32 A2 6x45 A2 8x42 A2 8x52

187

Lt = Anchor length h1 = Min. hole depth d0 = Hole depth Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Diameter of clearance hole in the fixture hmin = Minimum fixture thickness h = Minimum thickness equal to the thickness of member (hnom, red) and thickness of fixture (Tfix) hef = Embedment depth


universal and frame fixings

Vorpa TV Z

Universal nylon plug

Concrete

Solid brick

Perforated brick

Hollow brick

Aerated concrete

Perforated cement

Installation data Characteristic values to tensile load in daN

1 daN ≃1 kg

Substrate materials Ø screws (mm) Concrete C20/25 Autoclaved aerated concrete 3 N/mm2 Vulcanic tuff 7,5 N/mm2 Hollow brick 1,5 N/mm2 Solid brick 2,5 N/mm2 Hollow concrete thickness member equal to 2 cm

TV Z Ø6 Ø 4,5 390 60 70 79 48 53

TV Z Ø8 Ø5 63 24 11 86 56 63

Tensile and shear loads shown in the table are CHARACTERISTIC LOADS from tests carried out on non-cracked concrete C20/25 without edge and spacing effect (Pull out and shear loads are in kN: 1KN = 100Kg.) CHARACTERISTIC LOADS can be used for Ultimate limit state design of anchorages for use in concrete according to ETAG020-Part C. In case of concrete with a strength class lower than C20/25, or in case of further types of masonry, additional and special tests before installing are required.

ATTENTION: An appropriate safety factor = 5 should be applied on these values.

Examples of applications

188


universal and frame fixings

Vorpa VN

anti-rotation nylon plug 2 way expansion

Concrete

Solid brick

Products group

Flanged body VN

VN

VN a with chipboard screw

VN C with chipboard screw

VN 4 with zincplated hook

VN T with hexagonal head screw and washer

Suitable for • Concrete • Solid brick • Natural stone

To fix • Light carpentry • Curtains slide guides • Bath accessories • Lamps, paintings • Post boxes • Satellite dishes • Wall cupboards • Motion sensors • Information boards

Examples of applications

Product information Characteristics • Anti-rotation nylon plug 2 way expansion

Installation • To be mounted aligned the wall

Benefits • Fast and simple installation • Temperature resistant from -40°C to +80°C • The anti-rotation lock prevents the plug rotation in the drill hole • High level of installation safety • Possibility to direct the expansion forces to let them run parallel to the edge of the building material • To be used with wood and chipboard screws

Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation

189

Natural stone


universal and frame fixings

Vorpa VN

anti-rotation nylon plug 2 way expansion

Concrete

Solid brick

Installation sequence

Technical data

VN B flanged body

Code

435 436 437 438 438S 439

Description

d0 mm

Lt mm

h1 mm

Øv mm

VN B 5 VN B 6 VN B 8 VN B 10/50 VN B 10/60 VN B 12

5 6 8 10 10 12

26 31 41 51 61 61

35 40 55 70 80 75

3÷4 4÷5 4,5÷6 6÷8 6÷8 8÷10

VN

Code

649 630 631 648 632 633 3633 634 635 654

Description

d0 mm

Lt mm

h1 mm

Øv mm

VN 4 VN 5 VN 6 VN 7 VN 8 VN 10/50 VN 10/60 VN 12 VN 14 VN 16

4 5 6 7 8 10 10 12 14 16

20 25 30 30 40 50 60 60 75 80

25 35 40 40 55 70 80 75 85 90

2÷3 3÷4 4÷5 4÷5 4,5÷6 6÷8 6÷8 8÷10 10÷12 12÷14

644 645 646 647

Description

VN C 5 VN C 6 VN C 8 VN C 10

= Plug length = Min. hole depth = Hole diameter = Fixture thickness = Screw diameter = Screw length = Spanner

Screw length Lv = Lt + Tfix + Øv

VN C with chipboard screw

Code

Lt h1 d0 Tfix Ø v Lv Ch

d0 x Lt mm

h1 mm

Tfix mm

Øv x Lv mm

5 x 25 6 x 30 8 x 40 10 x 50

35 40 55 70

1,5 6 5 4

3,5 x 30 4,5 x 40 5 x 50 6 x 60

190

Natural stone


universal and frame fixings

Vorpa VN

anti-rotation nylon plug 2 way expansion

Concrete

Solid brick

Technical data

VN A with chipboard screw

Code

477 478 479 480

Description

VN A 5 VN A 6 VN A 8 VN A 10

d0 x Lt mm

h1 mm

Tfix mm

Øv x Lv mm

5 x 25 6 x 30 8 x 40 10 x 50

35 40 55 70

1,5 6 5 4

3,5 x 30 4,5 x 40 5 x 50 6 x 60

Lt h1 d0 Tfix Ø v Lv Ch

= Plug length = Min. hole depth = Hole diameter = Fixture thickness = Screw diameter = Screw length = Spanner

Screw length Lv = Lt + Tfix + Øv

VN T with hexagonal head screw and washer

Code

850 851 852 853 856 854

Description

VN T 8 VN T 10 VN T 12 VN T 14 /75 VN T 14 /100 VN T 16

d0 x Lt mm

h1 mm

Tfix mm

Øv x Lv mm

8 x 40 10 x 50 12 x 60 14 x 75 14 x 100 16 x 80

55 70 75 90 115 90

5 10 10 10 10 5

6 x 45 7 x 60 8 x 70 10 x 80 10 x 110 12 x 90

VN 4 with zincplated hook

Code

449

Description

VN 4

d0 mm

Lg mm

h1 mm

4

20

25

Installation data Tensile resistance in daN with wood screws Ø screws (mm) Concrete C20/25 Solid brick** Double brick UNI with plaster

VN 4 3 50 115

VN 5 4 200 170 200

1 daN ≃1 kg VN 6 5 300 250 300

VN 8 6 410 400 -

VN 10 8 700 -

VN 12 10 1020 -

VN 14 12 1600 -

VN 16 14 1900 -

ATTENTION: An appropriate safety factor = 5 should be applied on these values. As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.

191

Lt h1 d0 Tfix Ø v Lv Ch Øg Lg

= Plug length = Min. hole depth = Hole diameter = Fixture thickness = Screw diameter = Screw length = Spanner = Hook diameter = Hook length

Screw length Lv = Lt + Tfix + Øv

Natural stone


universal and frame fixings

Vorpa SU P Universal nylon plug

Concrete

Natural stone

Solid brick

Perforated brick

Plasterboard/ Light construction Perforated materials/ Panels cement Aerated Poroton

Products group SU P

SU P with chipboard screw

SU P with pan head screw cross recess

Suitable for • Concrete • Natural stone • Solid brick • Perforated brick • Plasterboard/Panels • Light construction materials/ Aerated Poroton • Perforated cement

To fix • Light carpentry • Curtains slide guides • Bath accessories • Lamps, paintings • Post boxes • Satellite dishes • Wall cupboards

SU P with wire hook

Expansion examples

On compact construction materials

On hollow construction materials and plasterboard / wood panels

Product information Characteristics • Universal multipurpose nylon plug

Installation • To be mounted aligned the wall

Benefits • Easy and quick fixings thanks to the segments of the body • Anti-rotation lugs stop the plug rotating in the drill hole • The fixing’s collar prevents it slipping into the drilled hole • Nylon safety and reliability • Temperature resistant from -40°C to +80°C • High level of installation security

Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation

Installation sequence

192


universal and frame fixings

Vorpa SU P Universal nylon plug

Concrete

Natural stone

Solid brick

Perforated brick

Plasterboard/ Light construction Perforated materials/ Panels cement Aerated Poroton

Technical data

SU P

Code

6900 6901 6902 6903

Description

d0 mm

Lt mm

h1 mm

Øv mm

SU P 6/35 SU P 6/45 SU P 8 SU P 10

6 6 8 10

35 45 50 60

45 55 60 80

3÷3,5 3÷3,5 4÷5 5÷6

SU P with chipboards screw

Code

6912 6913 6914 6915

Description

d0 x Lt mm

h1 mm

Tfix mm

Sc mm

Øv x Lv mm

SU PV 6/35 SU PV 6/45 SU PV 8 SU PV 10

6 x 35 6 x 45 8 x 50 10 x 10

45 55 60 80

10 10 10 20

6 6 6 6

3,5x45 3,5x55 4,5x60 6x80

SU P with pan head screw cross recess

Code

6916 6917 6918

Description

d0 x Lt mm

h1 mm

Tfix mm

Sc mm

Øv x Lv mm

SU PC 6/35 SU PC 6/45 SU PC 8/50

6 x 35 6 x 45 8 x 50

45 55 60

10 10 10

6 6 6

3,5x45 3,5x55 4,5x60

Sc mm

Øv x Lv mm

Øo x Lo mm

6 6

3,5x45 3,5x55

3,9x45 4,4x55

Lt h1 d0 Tfix Øv Lv Sc

= Plug length = Min. hole depth = Hole depth = Fixture thickness = Screw diameter = Screw length = Substrate thickness

SU P with wire hook

Code

6920 6921

Description

d0 x Lt mm

h1 mm

SU PU 6/45 SU PU 8/50

6 x 45 8 x 50

45 60

Tfix mm

Installation data Tensile resistance in daN with wood screws Ø screws (mm) Concrete C20/25 Solid brick** Double brick UNI with plaster** Plasterboard mm 10

1 daN ≃1 kg SU P6 3,5x45/55 100 70 40 35

SU P8 4,5x60 180 140 60 42

ATTENTION: An appropriate safety factor = 5 should be applied on these values.

SU P10 6x80 280 160 80 42

As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.

193


universal and frame fixings

Vorpa VR

Universal multipurpose plug

Concrete

Natural stone

Solid brick

Perforated brick

Aerated concrete

Aerated Poroton

Plasterboard Perforated cement

Products group To fix • Pictures • Lighting • Skirting • Shelves • Mirror cabinets • Letter boxes • Curtain rails • Electrical installation

Suitable for • Concrete • Natural stone • Solid brick • Perforated brick • Aerated concrete • Plasterboard • Aerated Poroton • Perforated cement

VR

VR with chipboard screw

Examples of applications

Expansion examples

On compact construction materials

On hollow construction materials

On plasterboard / wood panels

Product information Installation • To be mounted aligned the wall

Characteristics • Hd polyethylene plug suitable for applications on compact and hollow materials Benefits • Safe and quick fixings • Special anti-rotation wings that prevents the plug turning in the hole on installation • The plug’s neck avoid the introduction of the plug inside the hole • Resistant to temperatures from -40°C to +70°C • To be used with wood screws

Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation

194


universal and frame fixings

Vorpa VR

Universal multipurpose plug

Concrete

Natural stone

Solid brick

Perforated brick

Aerated concrete

Aerated Poroton

Plasterboard Perforated cement

Installation sequence

Technical data

VR

Code

531 532 533

Description

VR 6 VR 8 VR 10

d0 x Lt mm

h1 mm

Øv mm

6 x 38 8 x 51 10 x 61

48 61 71

3÷5 3,5÷7 5÷8

VR with chipboards screw

Code

541 542 543

Description

VR V 6 VR V 8 VR V 10

d0 x Lt mm

h1 mm

Tfix mm

Sc mm

Øv x Lv mm

6 x 38 8 x 51 10 x 61

48 61 71

8 8 8

6 6 6

4x45 5x60 6x70

= Plug length = Min. hole depth = Hole depth = Fixture thickness = Screw diameter = Screw length = Substrate thickness

Screw length Lv = Lt + Tfix + Øv

Installation data Tensile resistance in daN with wood screws Ø screws (mm) Concrete C20/25 Solid brick** Double brick UNI with plaster** Plasterboard mm 10

Lt h 1 d 0 Tfix Øv Lv S c

1 daN ≃1 kg VR 6 4x45 100 70 40 30

VR 8 5x60 160 130 55 40

VR 10 6x70 190 140 75 40

ATTENTION: An appropriate safety factor = 5 should be applied on these values. As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.

195


universal and frame fixings

Vorpa ZV

Nylon light fixing

Concrete

Natural stone

Solid brick

Perforated brick

Aerated Poroton

Aerated concrete

Perforated cement

Products group

ZV with screw

ZV doorstop

ZV short hook

ZV extra long cylinder head screw

ZV medium hook

ZV extra long short hook

ZV long hook

ZV extra long medium hook

ZV eyebolt

ZV extra long eyebolt

ZV wire bolt

ZV extra long wire hook

Suitable for • Concrete • Natural stone • Solid brick • Perforated brick • Aerated Poroton • Perforated cement • Aerated concrete To fix • Curtain slide guides • Lighting, paintings • Post poxes • Satellite dishes • Shelves, profiles • Door stops • Ceilings, hangers • Motion sensors • Bath accessories • Wall mounting for tv and radio

ZV stud and nut

ZV flat hook

ZV adjustable hook

Product information Installation • To be mounted aligned the wall

Characteristics • Nylon wallplug available in three different sizes 6-9-12 mm Ø • Wide range of pre-assembled accessories in zincplated steel • The wallplug expands upon return of the cone, when the accessory is tightened Benefits • The wallplug’s particular shape guarantees effective expansion • The side lugs prevent the wallplug from twisting around on its own axis • The opening along its length guarantees perfect adherence even on non solid materials • The collar prevents stressing claddings • Useful in a wide range of applications • Can be used on most popular building materials

Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation

196


universal and frame fixings

Vorpa ZV

Nylon light fixing

Concrete

Natural stone

Solid brick

Perforated brick

Aerated Poroton

Aerated concrete

Installation sequence ZV with accessories on solid materials

ZV with accessories on hollow materials

ZV with screw

ZV with stud and nut

ZV with door stop

Technical data

ZV with screw

Code

871 975 976

Description

d0 mm

Lt mm

h1 mm

Tfix mm

ZV 6 screw ZV 9 screw ZV 12 screw

6 9 12

30 45 50

48 61 71

5 10 10

197

Lt h1 d0 Tfix

= Plug length = Min. hole depth = Hole diameter = Fixture thickness

Perforated cement


universal and frame fixings

Vorpa ZV

Nylon light fixing

Concrete

Natural stone

Solid brick

Perforated brick

Aerated Poroton

Aerated concrete

Perforated cement

Technical data

ZV short hook

ZV medium hook

ZV long hook

Description

d0 mm

Lt mm

h1 mm

G mm

874 977 978

ZV 6 short hook ZV 9 short hook ZV 12 short hook

6 9 12

30 45 50

45 55 60

8 7 7

979 980

ZV 9 medium hook ZV 12 medium hook

9 12

45 50

55 60

11 11

981 982

ZV 9 long hook ZV 12 long hook

9 12

45 50

55 60

18 22

Description

d0 mm

Lt mm

h1 mm

Ø mm

ZV 6 eyebolt ZV 9 eyebolt ZV 12 eyebolt

6 9 12

30 45 50

45 55 60

8 12 13

Description

d0 mm

Lt mm

h1 mm

Ø mm

ZV 9 wire bolt ZV 12 wire bolt

9 12

45 50

55 60

12 13

Code

ZV eyebolt

Code

877 983 984

ZV wire bolt

Code

985 986

ZV stud and nut 30 mm

ZV stud and nut 50 mm

ZV stud and nut M6

Description

d0 mm

Lt mm

h1 mm

ØbxLb mm

Tfix mm

987 988

ZV 9 stud M4x30 ZV 12 stud M5x30

9 12

45 50

55 60

M4x30 M5x30

10 10

991 993

ZV 9 stud M4x50 ZV 12 stud M5x50

9 12

45 50

55 60

M4x50 M5x50

25 25

992

ZV 12 stud M6x20

12

50

60

M6x20

10

Code

198

Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Ø0 = Eyebolt diameter ØbxLb = Stud diameter x stud length


universal and frame fixings

Vorpa ZV

Nylon light fixing

Concrete

Natural stone

Solid brick

Perforated brick

Aerated Poroton

Aerated concrete

Perforated cement

Technical data

ZV flat hook Code

957 969

ZV adjustable hook Description

d0 mm

Lt mm

h1 mm

G mm

ZV 9 flat hook ZV 12 adjustable hook

9 12

45 50

55 60

14 5

d0 mm

Lt mm

h1 mm

AxB mm

9 9

45 45

55 55

Ø20x25 Ø20x25

ZV doorstop Code

989 990

Description

ZV 9 black doorstop ZV 9 white doorstop

ZV extralong cylinder head screw

Code

Description

d0 mm

Lt mm

h1 mm

Tfix mm

9 12

60 60

70 70

10 10

636 ZV 9 extralong cylinder head screw 638 ZV 12 extralong cylinder head screw

ZV extralong short hook

Code

Description

637 ZV 9 extralong short hook 639 ZV 12 extralong short hook

ZV extralong medium hook

d0 mm

Lt mm

h1 mm

G mm

9 12

60 60

70 70

7 7

ZV extralong eyebolt

ZV extralong wire hook

d0 mm

Lt mm

h1 mm

G mm

667 ZV 12 extralong medium hook 12 973 ZV 12 extralong eyebolt 12 974 ZV 12 extralong wire hook 12

60 60 60

70 70 70

11

Code

Description

P mm

Øo mm

13 13

199

Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Ø0 = Eyebolt diameter ØbxLb = Stud diameter x stud length


universal and frame fixings

Vorpa ZV

Nylon light fixing

Concrete

Natural stone

Solid brick

Perforated brick

Aerated Poroton

Aerated concrete

Perforated cement

Installation data Pull out values in daN ZV 6 Code Aerated poroton Concrete C20/25

1 daN ≃1 kg 871 40 40

*874 40 40

*877 40 40

975 160 220

*977 50 50

*979 50 50

*981 50 50

*983 50 50

*985 50 50

991 160 220

987 160 220

636 160 220

*637 50 50

976 210 350

*978 90 90

*980 90 90

*982 90 90

*984 90 90

*986 90 90

993 210 350

988 210 350

992 210 350

638 210 350

* Bending moment

Pull out values in daN ZV 9 Code Aerated poroton Concrete C20/25

1 daN ≃1 kg

* Bending moment

Pull out values in daN ZV 12 Code Aerated poroton Concrete C20/25

1 daN ≃1 kg

* Bending moment

ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values. As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.

200

*639 90 90

*667 90 90

*973 90 90

*974 90 90


universal and frame fixings

Vorpa SV

Universal light fixing

Concrete

Natural stone

Solid brick

Products group

SV with screw

SV doorstop

SV short hook

SV extra long hex head screw

SV medium hook

SV extra long cylinder head screw

SV long hook

SV extra long short hook

SV eyebolt

SV extra long medium hook

SV wire bolt

SV extra long eyebolt

SV stud and nut

SV extra long wire hook

SV stud and nut

Suitable for • Concrete • Natural stone • Solid brick To fix • Curtain slide guides • Lighting, paintings • Post poxes • Satellite dishes • Shelves, profiles • Door stops • Ceilings, hangers • Motion sensors • Bath accessories • Wall mounting for tv and radio

SV adjustable hook

Examples of applications SV flat hook

Product information Characteristics • Steel wallplug available in three different sizes 6-8-9 mm Ø • Wide range of pre-assembled accessories in zincplated steel • The wallplug expands upon return of the cone, when the accessory is tightened

Installation • To be mounted aligned the wall

Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data Benefits • Thanks to a vast assortment of special accessories this wallplug • Clean the hole before the installation is useful in a wide range of applications • Expansion is excellent thanks to the zincplated steel shieldings • The side lugs prevent the wallplug from twisting around on its own axis • The wallplug can be used on most popular building materials 201


universal and frame fixings

Vorpa SV

Universal light fixing

Concrete

Natural stone

Installation sequence SV light fixing with accessories on compact building materials

SV with screw

SV with stud and nut

SV with door stop

SV with adjustable hook

Technical data

SV with screw

Code

1675 1674 675 676

Description

SV 6 screw SV 6 long screw SV 8 screw SV 9 screw

d0 mm

Lt mm

h1 mm

Tfix mm

6 6 8 9

25 25 40 45

35 35 50 55

5 15 10 10

202

Lt h1 d0 Tfix

= Plug length = Min. hole depth = Hole diameter = Fixture thickness

Solid brick


universal and frame fixings

Vorpa SV

Universal light fixing

Concrete

Natural stone

Solid brick

Technical data

SV short hook

SV medium hook

SV long hook

d0 mm

Lt mm

h1 mm

G mm

SV 6 short hook SV 8 short hook SV 9 short hook

6 8 9

25 40 45

35 50 55

8 11 13

679 680

SV 8 medium hook SV 9 medium hook

8 9

40 45

50 55

15 17

681 682

SV 8 long hook SV 9 long hook

8 9

40 45

50 55

22 30

d0 mm

Lt mm

h1 mm

Øo mm

6 8 9

25 40 45

35 50 55

8 13 14

d0 mm

Lt mm

h1 mm

P mm

6 8 9

25 40 45

35 50 55

6 8 9

d0 mm

Lt mm

h1 mm

ØbxLb mm

8 9 9

40 45 45

50 55 55

M4x40 M6x20 M5x40

Code

1677 677 678

Description

SV eyebolt

Code

1683 683 684

Description

SV 6 eyebolt SV 8 eyebolt SV 9 eyebolt

SV wire bolt

Code

1685 685 686

Description

SV 6 wire bolt SV 8 wire bolt SV 9 wire bolt

SV stud M60x20 Code

687 689 688

SV stud M4 - M5

Description

SV 8 stud M4x40 SV 9 stud M6x20 SV 9 stud M5x40

203

Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Ø0 = Eyebolt diameter ØbxLb = Stud diameter x stud length


universal and frame fixings

Vorpa SV

Universal light fixing

Concrete

Natural stone

Solid brick

Technical data

SV flat hook Code

745 747

SV adjustable hook Description

SV 8 flat hook SV 9 adjustable hook

d0 mm

Lt mm

h1 mm

G mm

8 9

40 45

50 55

15 5

d0 mm

Lt mm

h1 mm

AxB mm

9 9

45 45

55 55

Ø20x25 Ø20x25

Lt h1 d0 Tfix G

= Plug length = Min. hole depth = Hole diameter = Fixture thickness = Hook

ZV doorstop Code

756 754

Description

SV 9 black doorstop SV 9 white doorstop

Installation data Pull out values in daN SV 6 Code Concrete C20/25

1 daN ≃1 kg 1675 40

*1677 40

*1683 40

*1685 40

675 300

*677 40

*679 40

*681 40

*683 40

*685 40

687 300

676 370

*678 90

*680 90

*682 90

*684 90

*686 90

688 370

* Bending moment

Pull out values in daN SV 8 Code Concrete C20/25

1 daN ≃1 kg

* Bending moment

Pull out values in daN SV 9 Code Concrete C20/25

1 daN ≃1 kg 689 370

* Bending moment

ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values. As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties.

204


universal and frame fixings

Vorpa SV

Universal light fixing

Concrete

Natural stone

Solid brick

Technical data

SV extra long hex head screw

Code

SV extra long cylinder head screw

Description

2860 2861

SV 9 screw TE SV 9 screw TC

SV extra long short hook Code

d0 mm

Lt mm

h1 mm

Tfix mm

9 9

60 60

70 70

10 10

SV extra long medium hook

Description

2862 SV 9 extralong short hook 2863 SV 9 extralong medium hook

d0 mm

Lt mm

h1 mm

G mm

9 9

60 60

70 70

15 20

d0 mm

Lt mm

h1 mm

Øo mm

9

60

70

14

d0 mm

Lt mm

h1 mm

P mm

9

60

70

9

SV extra long eyebolt

Code

Description

2864 SV 9 extralong eyebolt

SV extra long wire hook

Code

Description

2865 SV 9 extralong wire hook

Installation data Pull out values in daN SV 9 extra long fixing Code Concrete C20/25

2860 370

2861 370

1 daN ≃1 kg *2862 90

*2863 90

*2864 90

*2865 90

* Bending moment

ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values. As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties.

205


universal and frame fixings

Vorpa VE.O

Steel expansion anchor for ceilings

Concrete

Products group To fix • Ceilings • Hangers • Lightings • Ventilation systems • Suspended ceilings • Cable conduits

Suitable for • Concrete

Installation sequence

Product information Installation • To be mounted aligned the wall

Characteristics • Steel anchor with expansion clip for solid material • Suitable for ceilings and suspended hangers on limited material thickness Benefits • Simple hammerset installation and a short processing time • The extremely short anchor depth prevents reinfocement hits • The expansion clip guarantees a solid hold when fixed in the drill hole, and prevents it falling out during overhead installation • The nail anchor expands automatically under load. The cone is pulled into the expansion clip and expands it against the drill hole wall

Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation

Technical data

Code

559 1559

Description

d0 mm

Lt mm

h1 mm

VE.O 6/50 VE.O 6/60

6 6

50 60

65 75

VE.O 6/50 80

VE.O 6/60 80

Installation data Pull out values in daN Concrete C20/25

1 daN ≃1 kg

ATTENTION: An appropriate safety factor ≥ 4 should be applied on these values.

206


universal and frame fixings

Vorpa HC - HR

Light fixings in zamak for plasterboard

Boards and panels

Plasterboards

Aerated concrete

Products group

HC - L 31 mm

Suitable for • Boards and panels • Plasterboard • Aerated concrete

HC - L 39 mm

To fix • Skirting • Lamps, paintings • Curtains slide guides • Bath accessories • Profiles • Convectors • Information boards • Motion sensors

HR fixing anchor

Product information Installation • To be mounted aligned the wall

Characteristics • Self-threading zamak fixing for plasterboard, panels and light weight substrate materials Benefits • Need to pre-drill • Quick and easy installation work • Can be used with the most wideranging screws, hooks and eye screws. This allows for a broad range of applications • The sharp, self-tapping thread enables a secure, positive fit fixing • High load-bearing capacity • No special setting tool is required • Only a small amount of space is required behind the board (HC) • Suitable for prepositioned installation

Suggestion for use • The installation torque should be limited when using a battery operated screwdriver • Suitable for wood, self-tapping and chipboard screws of 4.0 to 5.0 mm diameter • No suitable for tiled plasterboard

Installation sequence HR

HC

207


universal and frame fixings

Vorpa HC - HR

tassello in zama per cartongesso

Pannelli Lastre

Cartongesso Cemento Cellulare

dati tecnici

Lt mm 31

Art.

520M 522M

Lt mm 39

Descrizione

Lt mm

Tfix mm

Si mm

ØvxLv mm

HC 31 HC 39

31 39

0-15 0-20

35 44

4x25 4,5x30

Lt mm 31

Art.

520V 522

Lt mm 39

2537 2539

Art.

523

Lt = Lunghezza tassello d0 = Diametro foro Tfix = Spessore fissabile Lv = Lunghezza vite Si = Spazio intercapedine LvxØv = Lunghezza vite x diametro vite Lunghezza vite > Lt + Tfix

HC con vite testa calottata

Descrizione

Lt mm

Tfix mm

Si mm

ØvxLv mm

HC TC 31 HC TC 39

31 39

0-15 0-20

35 44

4x25 4,5x30

Lt mm 31

Art.

HC

Lt mm 39

HC con vite testa svasata piana

Descrizione

Lt mm

Tfix mm

Si mm

ØvxLv mm

HC TSP 31 HC TSP 39

31 39

0-15 0-20

35 44

4x25 4,5x30

Descrizione

d0 mm

Lt mm

Tfix mm

Si mm

ØvxLv mm

HR 39

16

39

0-12

40

4,5x45

Installation dati tecnici data per l’installazione Resistenza alla trazione in daN Cartongesso singola parete 9,5 mm Cartongesso singola parete 12,5 mm Cartongesso doppia parete ≥ 25 mm

1 daN ≃1 kg HC 31 30 45 60

HC 39 45 55 70

ATTENZIONE: Si consiglia applicare un coefficiente di sicurezza pari a 5. Consultare la guida tecnica.

208

HC 39 55


universal and frame fixings

Vorpa HZ - HB

Nylon plug for plasterboard

Boards Plasterboards Aerated concrete and panels

Products group To fix • Skirting • Lightings, paintings • Curtains slide guides • Bath accessories • Shelves • Convectors • Motion sensors

Suitable for • Boards and panels • Plasterboard • Aerated concrete

HZ 29

HZ 29 TC

HZ 29 V TSP

HB 30

Product information Characteristics • Self-tapping nylon fixing for plasterboard

Installation • To be mounted aligned the wall

Benefits • No need to pre-drill • Quick and easy installation • Suitable for wood, self-tapping and chipboard screws

Suggestion for use • Not suitable for tiled plasterboard • The installation torque should be reduced when using a battery operated screw driver

Installation sequence

Technical data

Code

Description

Lt mm

Tfix mm

ØvxLv mm

2523s 2523 2755 521

HZ 29 nylon plug HZ 29 V TC nylon plug with cylinder head screw HZ 29 V TSP nylon plug with flat head screw HB 30 V nylon plug with countersunk head screw

29 29 29 30

13 13 13 12

4,5x25 4,5x25 4,5x25 3x25

Installation data Pull out values in daN

1 daN ≃1 kg HZ 40 50 67

Plasterboard 10 mm Plasterboard > 12,5 mm Plasterboard ≥ 25 mm

ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.

209

HB 20 30 45

Lt = Plug length Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length Si = Interspace Lv > Lt + Tfix


universal and frame fixings

Vorpa HS

Nylon plug with toggle designed for fixing on hollow materials

Aerated concrete

Hollow brick

Plasterboards

Boards and panels

Products group To fix • Curtain slide guides • Lighting, paintings • Post poxes • Satellite dishes • Shelves, profiles • Door stops • Ceilings, hangers • Motion sensors • Bath accessories • Wall mounting for tv and radio

Suitable for • Aerated concrete • Hollow brick • Plasterboard • Boards and panels HS with toggle

HS V with toggle and chipboard screw

Product information Characteristics • Nylon plug with toggle designed for fixing on hollow materials plasterboard, boards and panels • Suitable for metric and chipboard screws

Installation • To be mounted aligned the wall

Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values Benefits • The expanding arms swing open and press onto the reverse side • Respect the installation data • Clean the hole before the installation of the board • Reduced thermal transfer Installation sequence

Technical data HS nylon plug with toggle Code

Description

1050 HS 10x38 1051 HS 10x47

Lt mm

h1 mm

Øv mm

d0 mm

Tfix mm

38 47

30 42

4 4

10 10

12 19

Lt mm

h1 mm

ØvxLv mm

d0 mm

Tfix mm

38 47

30 42

4x50 4x55

10 10

12 19

HS nylon plug with toggle and chipboard screw Code

Description

1056 HS V 10x38 1057 HS V 10x47

Installation data Pull out values in daN

1 daN ≃1 kg HS 10 40 40

Plasterboard Hollow brick

ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values. 210

Lt h1 d0 Tfix Ø v Lv

= Plug length = Min. hole depth = Hole diameter = Fixture thickness = Screw diameter = Screw length

Screw lenght Lv = Lt + Tfix + Øv


universal and frame fixings

Vorpa HU

Metal cavity fixing for plasterboard

Hollow brick

Plasterboards

Boards and panels

Products group Suitable for • Hollow brick • Boards and panels • Plasterboard

Metal cavity fixing HU with screw

To fix • Skirting • Lightings, paintings • Curtains slide guides

Metal cavity fixing HU with hook screw

Metal cavity fixing HU with eye screw

Product information Characteristics • Metal cavity fixing with metric screw Benefits • Quick, easy and secure installation • The metric internal thread allows the attachment to be removed and refitted several times • The expanding arms ensure a large supporting surface • The claws around the edge of the fixing penetrate the board building material, preventing the fixing from rotating

Benefits • Load bearing capacity • During the installation procedure the expanding arms swing open and press onto the reverse side of the board • The metal fixing can be installed using installation pliers. If using a battery operated screwdriver or screwdriver for installation, the pre-assembled screws must be removed first Installation • To be mounted aligned the wall

Installation sequence Examples of applications

211


universal and frame fixings

Vorpa HU

Metal cavity fixing for plasterboard

Hollow brick

Plasterboards

Boards and panels

Technical data

Metal cavity fixing HU with screw

Code

1766 1767 1768 1769 770 771 1775 772 773 774

Description

Lt mm

ØvxLv mm

d0 mm

h1 mm

dp mm

Tfix mm

HU 4/20/7 HU 4/32/7 HU 4/38/7 HU 4/45/7 HU 5/37/9 HU 5/52/9 HU 5/65/9 HU 6/52/10 HU 6/65/10 HU 6/80/10

20 32 38 45 37 52 65 52 65 80

M4 x 28 M4 x 40 M4 x 45 M4 x 52 M5 x 45 M5 x 60 M5 x 72 M6 x 60 M6 x 72 M6 x 92

8 8 8 8 10 10 10 12 12 12

30 42 48 55 47 62 75 62 75 90

2-4 3-8 10-15 18+22 6-10 8-12.5 20-30 7-16 18-26 32-42

14 18 20 20 22 30 25 30 30 30

G

Lt h1 d0 Tfix Øv Lv dp

= Anchor length = Min. hole depth = Hole diameter = Fixture thickness = Screw diameter = Screw length = Panel thickness

Metal cavity fixing HU with hook screw

Code

1116

Description

Lt mm

ØvxLv mm

d0 mm

h1 mm

dp mm

G mm

HU

37

M5 x 45

10

47

6-10

12

5/37/9 G

Ø

Code

1117

Metal cavity fixing HU with eye screw

Description

Lt mm

ØvxLv mm

d0 mm

h1 mm

dp mm

Ø mm

HU 5/37/9 OA

37

M5 x 45

10

47

6-10

12

Code

Description

749 53128

HTU assembly plier HTU eye and bolt adapter

art. 749

Installation data

art. 53128

Pull out values in daN Code Screw - Plasterboard 9,5 mm Screw - Plasterboard 12,5 mm Screw - Plasterboard 19-20 mm Screw - Plasterboard ≥ 25 mm Hook - bending moment Eye bolt - bending moment

1 daN ≃1 kg HU 4 45 45 75 70 70

HU 5 45 45 75 90 90 90

ATTENTION: An appropriate safety factor ≥ 3 should be applied on these values. 212

HU 6 45 45 75 90 110 110

Examples of applications


universal and frame fixings

Vorpa DOUBLE-SIDED TAPE frame and universal fixings product group Suitable for To fix • plasterboard wall • plasterboard panels partition • metal profiles • guides to the paving Benefits: • Double-sided tape in polythene foam for insulation panels • Product waterproof, hotmelt adhesive and fronts in monosiliconati • Specific for noise reduction. To be applied on metal profiles for plasterboard partition walls • Ideal for metal profiles to be applied on non-drillable floors and ceilings • Suitable for joining of plasterboard walls, for the laying of partition walls and in the fixing of guides to the paving

Specific for noise reduction

Examples of application

technical data

Double-sided sealing tape for partition walls Code

* * 58770 58771 *

Width/length

Weigth

Adhesive weigth

polyethylene thickness

Thermal conductivity 40°C

mm 30x20 ml mm 40x20 ml mm 50x20 ml mm 70x20 ml mm 95x20 ml

73 g/m2 73 g/m2 73 g/m2 73 g/m2 73 g/m2

25 ± 10% g/m2 25 ± 10% g/m2 25 ± 10% g/m2 25 ± 10% g/m2 25 ± 10% g/m2

3 mm 3 mm 3 mm 3 mm 3 mm

0,039 W/mK 0,039 W/mK 0,039 W/mK 0,039 W/mK 0,039 W/mK

* Available on request

213


universal and frame fixings

Vorpa PC

Plasterboard and metal profiles special screws

Profiles

Boards and panels

Products group To fix • Metal plates • Thin profiles • Substructures of plasterboard • Connection of metal profiles

Suitable for • Profiles • Metal plates

PC V self-drilling screw with fine thread

PC A self-tapping screw with fine thread and drill tip

PC F self-tapping screw with drill tip and cylindric head

Examples of applications

Product information Characteristics • Self-drilling and self-tapping screws Benefits • The screws are phosphate-threated and thus provide the necessary corrosion protection • Efficient solution for serial machine assembly • Safe and economical • No pre-drilling required Technical data Lt = Plug length Tfix = Fixture thickness Øv = Screw diameter Øt = Head screw diameter Ch = Spanner Tfix = Lv - hef

PC V self-drilling screw with fine thread

Code

2850 2851 2852 2853

Description

PC V 3,5x25 PC V 3,5x35 PC V 3,5x45 PC V 3,5x55

ØvxLv mm

Tfix max mm

Øt mm

Ch mm

3,5x25 3,5x35 3,5x45 3,5x55

1 1 1 1

8 8 8 8

Ph2 Ph2 Ph2 Ph2

PC A self-tapping screw with fine thread and drill tip

Code

2890 2891 2892

Description

PC A 3,5x25 PC A 3,5x35 PC A 3,5x45

ØvxLv mm

Tfix max mm

Øt mm

Ch mm

3,5x25 3,5x35 3,5x45

2,25 2,25 2,25

8 8 8

Ph2 Ph2 Ph2

PC F self-tapping screw with drill tip and cylindric head

Code

2895 2897 2898 2896

Description

PC F 4,2x13 PC F 4,2x16 PC F 4,2x19 PC F 4,2x25

ØvxLv mm

Tfix max mm

Øt mm

Ch mm

4,2x13 4,2x16 4,2x19 4,2x25

3 3 3 3

10,5 10,5 10,5 10,5

Ph2 Ph2 Ph2 Ph2

214


universal and frame fixings

Vorpa WING TOGGLE VB Cavity fixing for hollow materials

Hollow brick

Plasterboards

Products group

VBA

VB E

VB

VBC

Suitable for • Gypsum plasterboard and gypsum fibreboards • Cavity floor slabs made from bricks and concrete • Chipboard • Plywood

VB

VBB

To fix • Lightings, paintings • Ceilings • Mirror cabinets • Light shelves • Pipe clamps • Profiles for slabs

Product information Characteristics • Cavity fixing VBA-VB-VBC-VBE: spring toggle • Cavity fixing VBB and VBD: gravity toggle Benefits • Maximum flexibility • High load-bearing capacity • Suitable for pre-positioned installation • When placed in the drill hole, the bearing elements of the gravity and spring toggles independently swing open behind the board • No special installation tool is required

Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation

Installation sequence

215

Boards and panels


universal and frame fixings

Vorpa WING TOGGLE VB Cavity fixing for hollow materials

Hollow brick

Plasterboards

Boards and panels

Technical data

P Ø0

Spring toggle VBA M4 Code

1670 1671 1672 1673

Description

Øv mm

d0 mm

Sv mm

Sc mm

P mm

Øo mm

VBA M4 SCREW VBA M4 STUD/NUT VBA M4 EYEBOLT VBA M4 WIRE BOLT

M4 M4 M4 M4

12 12 12 12

25 25 25 25

50 60 30 30

12

12,5 -

P

Ø0

Spring toggle VB M5 Code

670 671 672 673

Description

Øv mm

d0 mm

Sv mm

Sc mm

P mm

Øo mm

VB M5 VB M5 VB M5 VB M5

M5 M5 M5 M5

14 14 14 14

27 27 27 27

50 60 30 30

12

15 -

SCREW STUD/NUT EYEBOLT WIRE BOLT

P Ø0

Spring toggle VBC M6 Code

2674 2670 2671 2672 2673

Description

Øv mm

d0 mm

Sv mm

Sc mm

P mm

Øo mm

VBC M6 WING TOGGLE VBC M6 SCREW M6 x 80 VBC M6 STUD M6 x 100 VBC M6 EYEBOLT VBC M6 WIRE BOLT

M6 M6 M6 M6

17 17 17 17

30 30 30 30

40 50 25 25

13

14,5 -

Ø0 Øv d 0 Sc S v P

216

= Eyebolt diameter = Screw diameter = Hole diameter = Thickness of the fixture = Interspace = Passage of the hook


universal and frame fixings

Vorpa WING TOGGLE VB Cavity fixing for hollow materials

Hollow brick

Plasterboards

Boards and panels

Technical data

P Ø0

Gravity toggle VBB M6 Code

1700 703 700 701 702

Description

Øv mm

d0 mm

Sv mm

Sc mm

P mm

Øo mm

VBB M6 WING TOGGLE VBB M6 SCREW M6 x 100 VBB M6 STUD M6 x 100 VBB M6 EYEBOLT VBB M6 WIRE BOLT

M6 M6 M6 M6

15 15 15 15

75 75 75 75

40 60 30 30

13

14,5 -

P Ø0

Spring toggle VBE M8 Code

3674 3670 3671 3672 3673

Description

Øv mm

d0 mm

Sv mm

Sc mm

P mm

Øo mm

VBE M8 WING TOGGLE VBE M8 SCREW M8 x 100 VBE M8 STUD M8 x 100 VBE M8 EYEBOLT VBE M8 WIRE BOLT

M8 M8 M8 M8

20 20 20 20

40 40 40 40

50 50 20 20

10

11,8 -

M10

25

45

Spring toggle VBE M10

5674

VBE M10 WING TOGGLE

P

Gravity toggle VBD M8 heavy duty fixings Code

4674 4671 4673

Description

Øv mm

d0 mm

Sv mm

Sc mm

P mm

VBD M6 WING TOGGLE VBD M6 STUD M8 x 100 VBC M6 WIRE BOLT

M8 M8

20 20

75 75

60 60

16

Installation data Pull out values in daN Spring toggle with screw Spring toggle with stud/nut Spring toggle with eyebolt * Spring toggle with wirebolt *

1 daN ≃1 kg M4 120 120 40 40

M5 230 230 60 60

M6 350 350 100 100

M8 600 600 300 300

* Bending moment ** Fixing on metal profiles

ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values. 217

M10 800

M8 VBD 2000** 300

Ø0 Øv d 0 Sc S v P

= Eyebolt diameter = Screw diameter = Hole diameter = Thickness of the fixture = Interspace = Passage of the hook


universal and frame fixings

Vorpa WING TOGGLE VB M10 Cavity fixing hevy duty loads on hollow materials

Hollow brick

Plasterboards

Boards and panels

Products group

Thread M10

Code 5675 WING TOGGLE M10

Code 5676 WING TOGGLE M10 WITH BAR, NUTS, WASHER

Code 5679 For suspended sanitary ware

Product information Characteristics • Steel wing toggle with self-locking folding crosspiece inside the cavity • Suitable for fixings on perforated panels, panels of gypsum-fibra, prestressed concrete with alveolar core, corrugated metal profiles, cavities in general • Allows the application of very heavy loads • Possibility to add other accessories as bolts and eyelets hooks

Suitable for • floors with alveolar core • gypsum fibra • paving in perforated blocks • metal profiling • cavity in general • cavity foor slabs made from bricks and concrete

Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation

To fix • countertops • collars for exhaust pipes • heavy ducts • suspended profiles • suspended sanitary ware

Test reports available

Installation sequence

Installation data Determination of the mean tensile strength of the tilting anchor on a metal profile

VB M10

1 daN ≃1 kg

1080 daN

The type of support has an influence on the strength of the steel anchor. The values show in the table refer to the maximum resistance of the product; it is advisable to adopt an appropriate security coefficient. At least 4.

218


universal and frame fixings

Vorpa WING TOGGLE VB M10 Cavity fixing hevy duty loads on hollow materials

Hollow brick

Plasterboards

Boards and panels

Technical data

Øv Sv

Thread M10 Sc d0

Code 5675 WING TOGGLE M10

code 5676 WING TOGGLE M10 WITH BAR, NUTS, WASHER Øv mm

Code

Description

5675 5676

VBD M10 WING TOGGLE M10 VBD M10 WING TOGGLE M10 WITH BAR, NUTS, WASHER

d0 Sc mm mm

M10 30

80

Øv d0 S c Sv

Sv mm

= Screw diameter = Hole diameter = Thickness of the fixture = Interspace

90

Sc

Sv

d0 Ø

For suspended sanitary ware Code

Description

Øv mm

d0 mm

Sc mm

Sv mm

Lv mm

5679

VBD STUD M10x180 SANITARY WARE

M10

30

80

90

180

Examples of applications

219

Øv d0 S c Sv Lv

= Screw diameter = Hole diameter = Thickness of the fixture = Interspace = Stud length


universal and frame fixings

Vorpa WING TOGGLE VB M10 Cavity fixing heavy duty loads on hollow materials

Hollow brick

Plasterboards

Boards and panels

Products group

Thread M10

Code 5677 WING TOGGLE M10

Code 5678 WING TOGGLE M10 WITH BAR, NUTS, WASHER

Product information Characteristics • Steel wing toggle with self-locking folding crosspiece inside the cavity • Suitable for fixings on perforated panels, panels of gypsum-fibra, prestressed concrete with alveolar core, corrugated metal profiles, cavities in general • Allows the application of very heavy loads • Possibility to add other accessories as bolts and eyelets hooks Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation

Suitable for • floors with alveolar core • gypsum fibra • paving in perforated blocks • metal profiling • cavity in general • cavity foor slabs made from bricks and concrete

To fix • countertops • collars for exhaust pipes • heavy ducts • suspended profiles

Test reports available

Installation sequence

Installation data Determination of the mean tensile strength of the tilting anchor on a metal profile

VB M10

1 daN ≃1 kg

1500 daN

The type of support has an influence on the strength of the steel anchor. The values show in the table refer to the maximum resistance of the product; it is advisable to adopt an appropriate security coefficient. At least 4.

220


universal and frame fixings

Vorpa WING TOGGLE VB M10 Cavity fixing heavy duty loads on hollow materials

Hollow brick

Plasterboards

Boards and panels

Technical data

Øv Sv

Thread M10

Sc d0

Code 5677 WING TOGGLE M10

Code 5678 WING TOGGLE M10 WITH BAR, NUTS, WASHER

Code

Description

Øv mm

d0 mm

Sc mm

Sv mm

5677 5678

VBD M10 WING TOGGLE M10 VBD M10 WING TOGGLE M10 WITH BAR, NUTS, WASHER M10

22

60

90

Examples of applications

221

Øv d 0 Sc Sv

= Screw diameter = Hole diameter = Thickness of the fixture = Interspace


universal and frame fixings

Vorpa HZB

Nylon plug for fixings on light weight concrete blocks

Light construction materials

Products group Suitable for • Lightweight concrete blocks HZB

To fix • Light carpentry • Lamps, paintings • Post boxes • Satellite dishes • Wall cupboards • Wall mounting for TV and radio • Pipe clamps

Examples of applications

Product information Characteristics • External threaded nylon plug suitable for applications on lightweight concrete blocks (e.g. GASBETON). Benefits • Easy and quick fixings thanks to the external thread • The fixing’s collar prevents it slipping into the drilled hole • Nylon safety and reliability • To be used with chipboard screws, and metrical screws • Possible close to edge applications • Temperature resistant from -40°C to +80°C

Installation • To be mounted aligned the wall Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation • Drill the base material without using roto-percussion

222


universal and frame fixings

Vorpa HZB

Nylon plug for fixings on light weight concrete blocks

Light construction materials

Types of materials where the fixing application is possible

Installation sequence

Technical data

Code

Description

2766 HZB 10/50 2767 HZB 12/60 2768 HZB 14/70

d0 mm

Lt mm

h1 mm

ch mm

Øv metrica mm

Øv legno mm

10 12 14

50 60 70

60 70 80

6 8 10

M6 M8 M10

5,0-6,0 7,0-8,0 9,0-10,0 Lt h1 d0 Tfix Øv ch

= Anchor length = Min. hole depth = Hole diameter = Fixture thickness = Screw diameter = Hexagonal socket

Installation data Oblique axial pull out values in daN Cellular concrete

HZB 10 110

HZB 12 170

ATTENTION: An appropriate safety factor ≥ 3 should be applied on these values.

1 daN ≃1 kg HZB 14 230

As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.

223


universal and frame fixings

Vorpa VP

Hammer-in screw fixing

Concrete

Natural stone

Solid brick

Aerated concrete

Plasterboards

Products group Suitable for • Concrete • Natural stone • Solid brick • Aerated concrete • Plasterboards

VP X with flanged collar

VP TL with large flanged collar

VP INOX with large flanged collar and stainless steel screw

VP ZIP with flanged collar

To fix • Slides • Cable and pipe clamps • Wall connection or plaster profiles • Electrical installations • Plumbing • Door stops • Skirtings • Ducts • Covering installations

Examples of applications

VP NERO with flanged collar

VP RAME with large flanged collar and copper screw

VP RAMATO with copper plated screw, large covering head and large flanged collar

VP G RAME with copper screw, large covering head and large flanged collar

Installation sequence

Product information Characteristics • Hammer-in screw fixing for installations economic series • Various versions available Benefits • Rapid hammerset installation • The integrated hammer-in stop prevents the plug from expanding prematurely • Wide range of diameters, usage lengths and head shapes • Suitable for push-through installation • When hammered in, the nail screw causes the plug to expand in two directions

Installation • Through setting anchors Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation

224


universal and frame fixings

Vorpa VP

Hammer-in screw fixing

Concrete

Natural stone

Solid brick

Aerated concrete

Plasterboards

Technical data VP X with flanged collar Code

620 621 627 622 623 624

Description

VP X 5/30 VP X 6/40 VP X 6/50 VP X 6/60 VP X 8/50 VP X 8/70

dnom x Lt mm

h1 mm

Tfix mm

d0 mm

ØT mm

5 x 30 6 x 40 6 x 50 6 x 60 8 x 50 8 x 70

45 55 65 75 65 85

5 5 15 25 15 25

5 6 6 6 8 8

9 10 10 10 11 11

Pull out values in daN

1 daN ≃1 kg VPX5 90

Concrete C20/25

VPX6 140

VPX8 180

ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.

As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.

VP TL with large flanged collar

Code

440 441 425 426 427 1786 1787

Description

dnom x Lt mm

h1 mm

Tfix mm

d0 mm

ØT mm

VP TL 5/25 VP TL 6/30 VP TL 6/40 VP TL 6/50 VP TL 6/60 VP TL 6/80 VP TL 6/100

5 x 25 6 x 30 6 x 40 6 x 50 8 x 60 8 x 80 6 x 100

40 45 55 65 75 95 115

2 2 5 15 25 45 65

5 6 6 6 6 6 6

10 13 14 14 14 14 14

Pull out values in daN

1 daN ≃1 kg VP TL 5 90

Concrete C20/25

VP TL 6 140

ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.

As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.

VP INOX with large flanged collar and stainless steel screw

Code

1740 1741 1742 1743

Description

VP INOX VP INOX VP INOX VP INOX

6/30 6/40 6/50 6/60

dnom x Lt mm

h1 mm

Tfix mm

d0 mm

ØT mm

6 x 30 6 x 40 6 x 50 6 x 60

45 55 65 75

2 5 15 25

6 6 6 6

13 14 14 14

Pull out values in daN Concrete C20/25

1 daN ≃1 kg VP INOX 5 90

VP INOX 6 140

ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.

VP INOX 8 180

As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.

225

Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness dnom = Plug diameter ØT = Head screw diameter


universal and frame fixings

Vorpa VP

Hammer-in screw fixing

Concrete

Natural stone

Solid brick

Aerated concrete

Plasterboards

Technical data Hammer-in screw fixing VP with large flanged collar. INNOVATIVE DESIGN Code

Description

5740 VP ZIP 5/27 5741 VP ZIP 6/32

dnom x Lt mm

h1 mm

Tfix mm

d0 mm

ØT mm

5 x 27 6 x 32

35 40

3,5 5,0

5 6

11 13

Pull out values in daN

1 daN ≃1 kg VP ZIP 5 70 60 50

Concrete C20/25 Solid brick Hollow brick

VP ZIP 6 90 80 50

ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.

As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.

VP NERO with flanged collar Code

1750 1751 1752 1753

Description

VP NERO VP NERO VP NERO VP NERO

6/30 6/40 6/50 6/60

dnom x Lt mm

h1 mm

Tfix mm

d0 mm

ØT mm

6 x 30 6 x 40 6 x 50 6 x 60

45 55 65 75

2 5 15 25

6 6 6 6

13 14 14 14

Pull out values in daN

1 daN ≃1 kg VP NERO 6 140

Concrete C20/25

ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.

As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.

VP RAME with large flanged collar and copper screw

Code

1780 1781 1782 1783

Description

VP RAME VP RAME VP RAME VP RAME

6/30 6/40 6/50 6/60

dnom x Lt mm

h1 mm

Tfix mm

d0 mm

ØT mm

6 x 30 6 x 40 6 x 50 6 x 60

45 55 65 75

2 5 15 25

6 6 6 6

13 14 14 14

Pull out values in daN Concrete C20/25

1 daN ≃1 kg VP TL 5 90

VP TL 6 140

ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.

As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.

226

Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness dnom = Plug diameter ØT = Head screw diameter


universal and frame fixings

Vorpa VP

Hammer-in screw fixing

Concrete

Natural stone

Solid brick

Aerated concrete

Plasterboards

Technical data VP RAMATO with copper plated screw, large covering head and large flanged collar Code

430R 431R 430 431

Description

VP RAMATO 6/40 VP RAMATO 6/60 VP G RAME 6/40 VP G RAME 6/60

VP G RAME with copper screw, large covering head and large flanged collar

dnom x Lt mm

h1 mm

Tfix mm

d0 mm

ØT mm

6 x 40 6 x 60 6 x 40 6 x 60

55 75 55 75

5 25 5 25

6 6 6 6

14 14 14 14

Pull out values in daN Concrete C20/25

1 daN ≃1 kg VP INOX 5 90

VP INOX 6 140

ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.

VP INOX 8 180

As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.

227

Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness dnom = Plug diameter ØT = Head screw diameter


universal and frame fixings

Vorpa VP zamak

Hammer-in zamak preassembled plug

Concrete

Natural stone

Solid brick

Products group To fix • Slides • Cable and pipe clamps • Wall connection or plaster profiles • Electrical installations • Plumbing • Door stops • Skirtings • Ducts • Covering installations

Suitable for • Concrete • Natural stone • Solid brick

Installation sequence

Product information Characteristics • Hammer-in preassembled zamak plug

Installation • Through setting anchors

Benefits • Cost-efficient hammerset installation • Guarantees minimum movement when under load • High safety in use • The ceiling nail is driven into the drill hole with a hammer until it is firmly in position • At the end of the expansion of the pin against the drill hole wall, the hammer-in zamak plug guarantees protection against burglary and thievery

Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation

Technical data

Code

Description

2650 VP ZAMA 6/30 2651 VP ZAMA 6/40 2652 VP ZAMA 6/65

dnom x Lt mm

h1 mm

Tfix mm

d0 mm

6 x 30 6 x 40 6 x 65

40 50 75

5 15 35

6 6 6

Pull out values in daN Concrete C20/25 Solid brick

1 daN ≃1 kg 120 100

ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.

As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.

228

Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness dnom = Plug diameter


universal and frame fixings

Vorpa VPO

Hammer-in screw fixing countersunk flanged collar

Concrete

Natural stone

Solid brick

Products group Suitable for • Concrete • Natural stone • Solid brick

VPO hammer-in plug countersunk flanged collar

VPO hammer-in plug countersunk flanged collar stainless steel A2 screw

Examples of applications

To fix • Door frames/windows frames • Counter frames • Wood substructures • Profiles • Skirtings • Electrical installations • Wall connection or plaster profiles • Slides • Sheets • Cable and pipe clamps • Punched tapes • External wood deck

Examples of applications

Installation sequence

Product information Characteristics • Integrated hammer-in nylon plug for push-through installation

Installation • Through setting anchors

Benefits • Easy fast and economical fixing • Suitable for substructures made of wood and metal • Ideal for an economic series installation • The hammer in plug structure prevents the plug from expanding prematurely • The thread of the nail screw allows the screw to be removed • When hammered in, the nail screw causes the plug to expand in two directions

Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation

229


universal and frame fixings

Vorpa VPO

Hammer-in screw fixing countersunk flanged collar

Concrete

Natural stone

Solid brick

Technical data VPO hammer-in plug countersunk flanged collar

Code

690 662 1663 663 691 1664 664 692 693 694 698 668 699 2950 2951 2952

Description

dnom x Lt mm

h1 mm

Tfix mm

d0 mm

VP O VP O VP O VP O VP O VP O VP O VP O VP O VP O VP O VP O VP O VP O VP O VP O

5 x 35 5 x 50 6 x 40 6 x 50 6 x 60 6 x 70 6 x 80 8 x 60 8 x 80 8 x 100 8 x 120 8 x 135 10 x 100 10 x 120 10 x 140 10 x 160

45 60 50 60 70 80 90 70 90 110 130 145 110 130 150 170

5 20 10 20 30 40 50 20 40 60 80 95 60 70 90 100

5 5 6 6 6 6 6 8 8 8 8 8 10 10 10 10

5/35 5/50 6/40 6/50 6/60 6/70 6/80 8/60 8/80 8/100 8/120 8/135 10/100 10/120 10/140 10/160

Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Hole diameter in the fixture dnom = Plug diameter

VPO hammer-in plug countersunk flanged collar stainless steel A2 screw Code

3643 3644 3645 3646 3647 3648

Description

VP O VP O VP O VP O VP O VP O

A2 A2 A2 A2 A2 A2

6/40 6/60 6/80 8/60 8/80 8/100

dnom x Lt mm

h1 mm

Tfix mm

d0 mm

6 x 40 6 x 60 6 x 80 8 x 60 8 x 80 8 x 100

55 75 95 75 95 115

10 30 50 20 40 60

6 6 6 8 8 8

Pull out values in daN Concrete C20/25 Solid brick

1 daN ≃1 kg VP 5 90 80

VP 6 140 110

VP 8 180 150

ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.

VP 10 310 280

As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.

230

Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Hole diameter in the fixture dnom = Plug diameter


universal and frame fixings

Vorpa VPI

Hammer-in screw fixing flanged collar

Concrete

Natural stone

Solid brick

Products group Suitable for • Concrete • Natural stone • Solid brick

VPI hammer-in plug flanged collar

Examples of applications

To fix • Door frames/windows frames • Counter frames • Wood substructures • Profiles • Skirtings • Electrical installations • Wall connection or plaster profiles • Slides • Sheets • Cable and pipe clamps • Punched tapes

Examples of applications

Installation sequence

Product information Characteristics • Integrated hammer-in nylon plug for push-through installation

Installation • Through setting anchors

Benefits • Easy fast and economical fixing • Suitable for substructures made of wood and metal • Ideal for an economic series installation • The hammer in plug structure prevents the plug from expanding prematurely • The thread of the nail screw allows the screw to be removed • When hammered in, the nail screw causes the plug to expand in two directions

Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation

231


universal and frame fixings

Vorpa VPI

Hammer-in screw fixing flanged collar

Concrete

Natural stone

Solid brick

Technical data

VPI hammer-in plug flanged collar

Code

Description

dnom x Lt mm

h1 mm

Tfix mm

d0 mm

2689 2690N 2626 2663 2691N 2664 2665 2692 2693 2628 2694 2698 2699N

VP I 5/25 VP I 5/30 VP I 5/50 VP I 6/50 VP I 6/60 VP I 6/80 VP I 8/50 VP I 8/60 VP I 8/70 VP I 8/80 VP I 8/100 VP I 8/120 VP I 8/140

5 x 25 5 x 30 5 x 50 6 x 50 6 x 60 6 x 80 8 x 50 8 x 60 8 x 70 8 x 80 8 x 100 8 x 120 8 x 140

35 40 60 60 70 90 60 70 80 90 110 130 150

3 5 20 20 30 50 10 20 30 40 60 80 100

5 5 5 6 6 6 8 8 8 8 8 8 8

Pull out values in daN Concrete C20/25 Solid brick

1 daN ≃1 kg VP 5 90 80

VP 6 140 110

VP 8 180 150

ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.

VP 10 310 280

As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.

232

Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Hole diameter in the fixture dnom = Plug diameter


universal and frame fixings

Vorpa VP I CE

Hammer-in screw fixing with European Technical Approval

Concrete

Natural stone

Solid brick

Products group

VP I CE hammer-in plug

ETAG 014

Approved for • Non-cracked concrete for fixing of external thermal insulation composite system use cat. A Also suitable for • Natural stone • Solid brick

To fix • Door frames/windows frames • Counter frames • Wood substructures - profiles • External the thermal insulation profiles • Skirtings insulation profiles

Use categories A As it can also be used on concrete with different strength characteristics, as specified in ETA, on compact natural stone and others materials (exception not included in ETA), specific on-site tests by the user are necessary

Examples of applications

Installation sequence

Product information Installation Characteristics • Through setting anchors • Integrated hammer-in nylon plug for push-through installation • Nailed-in plastic anchors for fixing of External thermal insulation Suggestion for use composite system with rendering in concrete ETAG 014 • Always consider an appropriate safety factor • Check load bearing capacity values Benefits • Respect the installation data • Easy fast and economical fixing • Clean the hole before the installation • Suitable for substructures made of wood and metal • Ideal for an economic series installation • The hammer in plug structure prevents the plug from expanding prematurely • The thread of the nail screw allows the screw to be removed • When hammered in, the nail screw causes the plug to expand in two directions

233


universal and frame fixings

Vorpa VP I CE Hammer-in screw fixing

Concrete

Natural stone

Solid brick

Technical data

VP I CE hammer-in plug

Code

4154 4155 4156 4157 4158 4159 4160 4161 4162

Description

dnom x Lt mm

Øv x Lv mm

h1 mm

Tfix mm

d0 mm

hef mm

VP I CE VP I CE VP I CE VP I CE VP I CE VP I CE VP I CE VP I CE VP I CE

6 x 40 6 x 50 6 x 60 6 x 80 8 x 60 8 x 80 8 x 100 8 x 120 8 x 140

4 x 45 4 x 65 4 x 85 5 x 50 5 x 65 5 x 85 5 x 105 5 x 125 5 x 145

50 60 70 90 70 90 110 130 150

10 20 30 50 20 40 60 80 100

6 6 6 6 8 8 8 8 8

30 30 30 30 40 40 40 40 40

6/40 6/50 6/60 6/80 8/60 8/80 8/100 8/120 8/140

Installation data

Non-cracked concrete Use category A Installation data Minimum spacing Minimum edge distance Minimum thicknes of the member

Smin Cmin hmin

1 kN ≃100 kg mm 100 mm 100 mm 100

Characteristic values NON-CRACKED CONCRETE Pull out failure Nrk,P C12/15 Nrk,P C20/25-C50/60 Values where the reduction factor γ is included (Design loads) Pull out failure Nrk,P C12/15 Nrk,P C20/25-C50/60 Recommended loads Pull out failure C12/15 C20/25-C50/60 application on solid brick: not covered by ETA Characteristic values SOLID BRICK Pull out failure **solid brick

N N

KN KN

KN KN

KN KN

KN

VP I CE 6

VP I CE 8

0,50 0,75

0,40 0,60

VP I CE 6

VP I CE 8

0,25 0,38

0,20 0,30

VP I CE 6

VP I CE 8

0,16 0,24

0,13 0,20

VP I CE 6

VP I CE 8

0,30

0,20

ATTENTION: An appropriate safety factor ≥ 3 should be applied on these values on solid brick.

234

Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Hole diameter in the fixture dnom = Plug diameter hef = Embedment depth


universal and frame fixings

Vorpa VP C CE

Multi-purpose nylon fixing with European Technical Assesment

Concrete

Solid brick

Perforated brick

Hollow brick

Vulcanic Tuf

Poroton

Products group Approved for • Cracked and non-cracked concrete C12/15 - C50/60 use cat. A-B-C-D ETAG 020

VP C TSP

Also suitable for • Solid brick • Perforated brick • Hollow brick • Vulcanic tuf • Aerated concrete

VP C TE VP C TE A4

To fix • Window and door frames • Light structural works • Wooden substructures • Handrail

R90 only Ø10

VP C TC

ETAG 020 Use cat. A-B-C-D

Examples of applications

Product information Characteristics • Extra long nylon fixing with countersunk or cylinder edge suitable for applications on compact and hollow materials. Supplied with different types of screws Benefits • Safe and quick fixings • Special anti-rotation wings that prevents the plug turning in the hole on installation • The plug’s neck avoid the introduction of the plug inside the hole • Resistant to temperatures from -40°C to +80°C • European Technical Approval ETAG 020 • Special wings to avoid turning The special anti-rotation wings on the nylon sleeve provides easy and safe installation on all types of material, avoiding any rotation of the nylon sleeve while the screw is installed • No waiting time before loading • Ideal for fixing of facade, frames and general fastenings

Benefits • Fully radial expansion behaviour on concrete and solid masonry • Multiple radial expansion behaviour on perforated masonry • Knotting behaviour on hollow masonry • Temperature resistant from -40°C to + 80°C • Fire resistant only Ø10 R90 Installation • Through setting anchors Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation

235


universal and frame fixings

Vorpa VP C CE Multi-purpose nylon fixing

Concrete

Solid brick

Perforated brick

Hollow brick

Vulcanic Tuf

Poroton

Installation sequence On compact materials

Make a drill hole with a hammer drill

Clean the hole

Place the fixture and then insert the anchor into the hole

Put the anchor by hammering softly on the screw head until the fixture stops the nylon plug

Make sure that the fixture is supported by the anchor (nylon plug and screw)

Clean the hole

Place the fixture and the anchor into the hole by hand

Put the anchor by hammering softly on the screw head until the fixture stops the nylon plug

Sent the screw by screw driver or by hand. Make sure that the fixture is supported by the anchor (nylon plug and screw)

On hollow materials

Make a drill hole just by rotary drilling

Technical data

Nylon plug VP C with Torx recess flat countersunk head screw

Code Code Zincplated St. Steel

6100 6101 6102 6103 6104 * 6105 * 6106 * 6107 * 6108 * 6109 * 6110 *

6196 6197 6198 6199 6200 * 6201 * 6202 * 6203 * 6204 * 6205 * 6206 *

Description

dnom x Lt mm

Øv x Lv mm

h1 mm

Tfix mm

d0 mm

hef mm

df mm

T

VP C 8/80 TSP VP C 8/100 TSP VP C 8/120 TSP VP C 8/140 TSP VP C 10/80 TSP VP C 10/100 TSP VP C 10/120 TSP VP C 10/140 TSP VP C 10/160 TSP VP C 10/200 TSP VP C 10/230 TSP

8x80 8x100 8x120 8x140 10x80 10x100 10x120 10x140 10x160 10x200 10x230

6x85 6x105 6x125 6x145 7x85 7x105 7x125 7x145 7x165 7x205 7x235

90 90 90 90 90 90 90 90 90 90 90

10 30 50 70 10 30 50 70 90 130 160

8 8 8 8 10 10 10 10 10 10 10

70 70 70 70 70 70 70 70 70 70 70

9 9 9 9 11 11 11 11 11 11 11

TX30 TX30 TX30 TX30 TX40 TX40 TX40 TX40 TX40 TX40 TX40

*VS-Handyplug Ø10: at least 90 minutes fire resistance (R90) for fastening of façade systems on concrete, if the admissible load ≤0,8 [kN] (no permanent centric tension load).

236

Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Diameter of clearance hole in the fixture dnom = Plug diameter hef = Embedment depth


universal and frame fixings

Vorpa VP C CE Multi-purpose nylon fixing

Concrete

Solid brick

Perforated brick

Hollow brick

Vulcanic Tuf

Poroton

Technical data

Nylon plug VP C with Torx recess hexagonal washer head special wood screw

Code Code Zincplated St. Steel

6112 6113 6114 6115 6116 * 6117 * 6118 * 6119 * 6120 * 6121 * 6122 *

6184 6185 6186 6187 6188 * 6189 * 6190 * 6191 * 6192 * 6193 * 6194 *

Description

dnom x Lt mm

Øv x Lv mm

h1 mm

Tfix mm

d0 mm

hef mm

df mm

Ch

T

VP C 8/80 TE VP C 8/100 TE VP C 8/120 TE VP C 8/140 TE VP C 10/80 TE VP C 10/100 TE VP C 10/120 TE VP C 10/140 TE VP C 10/160 TE VP C 10/200 TE VP C 10/230 TE

8x80 8x100 8x120 8x140 10x80 10x100 10x120 10x140 10x160 10x200 10x230

6x85 6x105 6x125 6x145 7x85 7x105 7x125 7x145 7x165 7x205 7x235

90 90 90 90 90 90 90 90 90 90 90

10 30 50 70 10 30 50 70 90 130 160

8 8 8 8 10 10 10 10 10 10 10

70 70 70 70 70 70 70 70 70 70 70

9 9 9 9 11 11 11 11 11 11 11

10 10 10 10 13 13 13 13 13 13 13

TX30 TX30 TX30 TX30 TX40 TX40 TX40 TX40 TX40 TX40 TX40 Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Diameter of clearance hole in the fixture dnom = Plug diameter hef = Embedment depth

Nylon plug VP C with Torx recess mushroom head special wood screw

Code

6124 6125 6126 6127 6128 6129 * 6130 * 6131 * 6132 * 6133 *

Description

dnom x Lt mm

Øv x Lv mm

h1 mm

Tfix mm

d0 mm

hef mm

T

VP C 8/80 TC VP C 8/100 TC VP C 8/120 TC VP C 8/140 TC VP C 10/80 TC VP C 10/100 TC VP C 10/120 TC VP C 10/140 TC VP C 10/160 TC VP C 10/200 TC

8x80 8x100 8x120 8x140 10x80 10x100 10x120 10x140 10x160 10x200

6x85 6x105 6x125 6x145 7x85 7x105 7x125 7x145 7x165 7x205

90 90 90 90 90 90 90 90 90 90

10 30 50 70 10 30 50 70 90 130

8 8 8 8 10 10 10 10 10 10

70 70 70 70 70 70 70 70 70 70

TX30 TX30 TX30 TX30 TX40 TX40 TX40 TX40 TX40 TX40

*VS-Handyplug Ø10: at least 90 minutes fire resistance (R90) for fastening of façade systems on concrete, if the admissible load ≤0,8 [kN] (no permanent centric tension load).

237

Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Diameter of clearance hole in the fixture dnom = Plug diameter hef = Embedment depth


universal and frame fixings

Vorpa VP C CE Multi-purpose nylon fixing

Concrete

Solid brick

Perforated brick

Cracked and non-cracked concrete (C16/20) Installation data Minimum spacing Smin Minimum edge distance Cmin Minimum thicknes of the member hmin

mm mm mm

VP C Ø8 90 90 140

VP C Ø10 100 100 140

Pull out characteristic values VP C Temperature range Characteristic resistance

°C kN

VP C Ø8 24-40 50-80 3.5 3.0

VP C Ø10 24-40 50-80 4.5 4.0

T NRK,p

Use category A

Installation data

Solid masonry 110x60x240 “Danesi” (density 1,7 Kg/dm3 - min. compression strenght 39 N/mm2) Installation data VP C Ø8 VP C Ø10 Single anchor Minimum edge distance Cmin mm 120 120 Group of anchors Minimum edge distance Cmin mm 120 120 Minimum spacing S1min mm 240 240 (perpendicular to free edge) Minimum spacing S2min mm 480 480 (parallel to free edge) Minimum thicknes of the member hmin mm 110 110

NRK,p

kN

VP C Ø8 3.0

VP C Ø10 2.0

Solid masonry 250x120x55 “Terreal Italia” (density 1,7 Kg/dm3 - min. compression strenght 27 N/mm2) Installation data VP C Ø8 VP C Ø10 Single anchor Minimum edge distance mm 120 120 Cmin Group of anchors Minimum edge distance mm 125 125 Cmin Minimum spacing mm 250 250 S1min (perpendicular to free edge) Minimum spacing mm 500 500 S2min (parallel to free edge) Minimum thicknes of the member hmin mm 120 120 Pull out characteristic values VP C Characteristic resistance

NRK,p

kN

VP C Ø8 4.0

VP C Ø10 5.0

Solid masonry fine tuff 370x370x110 “Cave riunite” (density 2,4 Kg/dm3 - min. compression strenght 7,5 N/mm2) Installation data VP C Ø8 VP C Ø10 Single anchor Minimum edge distance mm 185 185 Cmin Group of anchors Minimum edge distance mm 185 185 Cmin Minimum spacing mm 370 370 S1min (perpendicular to free edge) Minimum spacing mm 740 740 S2min (parallel to free edge) Minimum thicknes of the member hmin mm 370 370 Pull out characteristic values VP C Characteristic resistance

NRK,p

kN

VP C Ø8 -

VP C Ø10 0.3

Calcium silicate solid brick KS-R(P)-202.0 - 8DF (240) “Heidelberg - Kalksandstein” (density 1.9 Kg/dm3 - min. compression strenght 28.2 N/mm2) Installation data VP C Ø8 VP C Ø10 Single anchor Minimum edge distance mm 120 120 Cmin Group of anchors Minimum edge distance mm 240 240 Cmin Minimum spacing mm S1min (perpendicular to free edge) 480 480 Minimum spacing mm S2min (parallel to free edge) 120 120 Minimum thicknes of the member hmin mm 240 240 Pull out characteristic values VP C Characteristic resistance

NRK,p

kN

VP C Ø8 5.5

VP C Ø10 6.0

238

Use category B

Pull out characteristic values VP C Characteristic resistance

Hollow brick

Vulcanic Tuf

Poroton


universal and frame fixings

Vorpa VP C CE Multi-purpose nylon fixing

Concrete

Solid brick

Perforated brick

Installation data

Solid masonry doppio UNI 120x245x250 “Danesi” (density 0.9 Kg/dm3 min. compression strenght 13 N/mm2))

Installation data Single anchor Minimum edge distance Group of anchors Minimum edge distance Minimum spacing (perpendicular to free edge) Minimum spacing (parallel to free edge) Minimum thicknes of the member

VP C Ø10

Cmin

mm

125

125

Cmin S1min

mm mm

125 250

125 250

S2min

mm

500

500

hmin

mm

120

120

NRK,p

kN

VP C Ø8 -

VP C Ø10 0.3

Use category C

Pull out characteristic values VP C Characteristic resistance

VP C Ø8

Hollow brick 120x250x250 “Wienerberger” (density 0.6 Kg/dm3 min. compression strenght 2,0 N/mm2)

Installation data Single anchor Minimum edge distance Group of anchors Minimum edge distance Minimum spacing (perpendicular to free edge) Minimum spacing (parallel to free edge) Minimum thicknes of the member Pull out characteristic values VP C Characteristic resistance

VP C Ø8

VP C Ø10

Cmin

mm

125

125

Cmin S1min

mm mm

75 250

75 250

S2min

mm

500

500

hmin

mm

120

120

NRK,p

kN

VP C Ø8 0.3

VP C Ø10 -

239

Hollow brick

Vulcanic Tuf

Poroton


universal and frame fixings

Vorpa VP C CE Multi-purpose nylon fixing

Concrete

Solid brick

Perforated brick

Installation data

500 10 15 35

235

5

Poroton T-24,0-0,9 “Wieneberger” (density 0.9 Kg/dm3 min. compression strenght 7.0 N/mm2)

15

235

110

Installation data 235 Single anchor 15 Minimum edge distance Group of anchors 10 Minimum spacing 25 (perpendicular to free edge) 500 Minimum spacing 10 10 15 edge) (parallel to free 18 Minimum edge 35 distance Minimum thicknes of the member 5 Pull out characteristic values VP C Characteristic resistance 15

VP C Ø8

VP C Ø10

Cmin

mm

120

120

S1min

mm

240

240

S2min

mm

480

480

Cmin hmin

mm mm

120 240

120 240

NRK,p

kN

VP C Ø8 0.9

VP C Ø10 0.9

240 30

25

Use category C

175

35 10 235

21

15

25 10

28

38

110

25 10

Poroton HIZB - ZDF - 0.9 “Wieneberger” (density 0.9 Kg/dm3 min. compression strenght 16.4 N/mm2)

18

175

Installation data Single anchor Minimum edge distance 240 Cmin Anchor Group 30 25 Minimum spacing 35 S1min (perpendicular to free edge) 10 21 Minimum spacing S2min 25 (parallel to free edge) 28 Minimum edge distance Cmin38 Minimum thicknes of the member hmin Pull out characteristic values VP C Characteristic resistance

NRK,p

VP C Ø8

VP C Ø10

mm

120

120

mm

240

240

mm

480

480

mm mm

120 115

120 115

kN

VP C Ø8 0.9

VP C Ø10 0:9

240

Hollow brick

Vulcanic Tuf

Poroton


235

universal and frame fixings 15

Vorpa VP C CE 10

Multi-purpose nylon fixing

Concrete

10

18

Solid brick

Perforated brick

Installation data

240 30

25

21

10 25 28

Hollow calcium silicate brick “Heidelberger - Kalksanstein” (density 1.5 Kg/dm3 min. compression strenght 16.3 N/mm2)

38

Installation data Single anchor Minimum edge distance Group of anchors Minimum spacing (perpendicular to free edge) Minimum spacing (parallel to free edge) Minimum edge distance Minimum thicknes of the member Pull out characteristic values VP C Characteristic resistance

VP C Ø8

VP C Ø10

Cmin

mm

120

120

S1min

mm

240

240

S2min

mm

480

480

Cmin hmin

mm mm

120 175

120 175

NRK,p

kN

VP C Ø8 5.0

VP C Ø8 5.5

Use category C

175

35

Autoclaved aerated concrete (density 0.5 Kg/dm3 min. compression strenght 3.5 N/mm2)

Installation data Single anchor Minimum edge distance Group of anchors Minimum spacing (perpendicular to free edge) Minimum spacing (parallel to free edge) Minimum edge distance Minimum thicknes of the member Pull out characteristic values VP C Characteristic resistance

VP C Ø8

VP C Ø10

Cmin

mm

240

240

S1min

mm

120

120

S2min

mm

240

240

Cmin hmin

mm mm

480 120

480 120

NRK,p

kN

VP C Ø8 0.5

VP C Ø8 0.6

Use categories a b

Subcategories

c

C hollow brick UNI 13 N/mm2 D hollow brick 2 N/mm2 G Poroton 7 N/mm2 H Poroton 16.4 N/mm2 I Hollow calcium silicate brick 16.3 N/mm2

Substrates Concrete C12/15 - C50/60

A solid brick 39 N/mm2 B solid brick 27 N/mm2 E fine tuff 7,5 N/mm

Autoclaved aerated concrete

241

Use category D

110

25

Hollow brick

Vulcanic Tuf

Poroton


universal and frame fixings

Vorpa VP R6

Nylon frame fixings with multiple wings

Concrete

Solid brick

Hollow brick

Products group

VP R6 Nylon frame fixing

Suitable for • Concrete • Solid brick • Hollow brick • Natural stone

To fix • Light carpentry • Wood coatings • Handrails • Wood substructures • Door frames • Window frames • Counter frames

VP R6 E Nylon frame with chipboard screw Examples of applications

VP R6 ET Nylon frame fixing with Torx recess chipboard screw

VP R6 IA2 nylon frame fixing with stainless steel chipboard screw

VP R6 Z nylon frame fixing with hexagonal bolt screw

VP R6 VS nylon frame fixing with safety Torx recess screw

Product information Characteristics • Nylon frame fixing with multiple wings

Installation • Through setting anchors

Benefits • Suitable for use in all solid and hollow building materials • Guarantees a simple installation • Wide range of applications • Suitable for push-through installation • Plug with special anti-rotation wings • The higher lenght allows the anchor to contain the entire thickness of the element to be fastened

Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation

242

Natural stone


universal and frame fixings

Vorpa VP R6

Nylon frame fixings with multiple wings

Concrete

Solid brick

Hollow brick

Natural stone

Installation sequence On compact materials

Make a drill hole with a hammer drill

Clean the hole

Place the fixture and then insert the anchor into the hole

Put the anchor by hammering softly on the screw head until the fixture stops the nylon plug

Make sure that the fixture is supported by the anchor (nylon plug and screw)

Clean the hole

Place the fixture and the anchor into the hole by hand

Put the anchor by hammering softly on the screw head until the fixture stops the nylon plug

Sent the screw by screw driver or by hand. Make sure that the fixture is supported by the anchor (nylon plug and screw)

On hollow materials

Make a drill hole just by rotary drilling

Product information

Technical data VP R6 Nylon frame fixing

Code

565 520 1564 566 568 569 570 567 1568

Description

d0 mm

h1 mm

Lt mm

Tfix mm

hef mm

df mm

screws mm

VP R6 VP R6 VP R6 VP R6 VP R6 VP R6 VP R6 VP R6 VP R6

8 8 8 10 10 10 10 10 10

90 110 130 90 110 125 145 170 210

80 100 120 80 100 115 135 160 200

10 30 50 10 30 45 65 90 130

70 70 70 70 70 70 70 70 70

8 8 8 10 10 10 10 10 10

5,5 5,5 5,5 7 7 7 7 7 7

8/80 8/100 8/120 10/80 10/100 10/115 10/135 10/160 10/200

243

Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Ă˜v = Screw diameter Lv = Screw length df = Hole diameter in the fixture dnom = Plug diameter hef = Effective embedment depth ch = Spanner


universal and frame fixings

Vorpa VP R6

Nylon frame fixings with multiple wings

Concrete

Solid brick

Hollow brick

Natural stone

Technical data

VP R6 nylon frame with chipboard screw

Code

1283 289 1284 1285 285 286 287 288 303

Description

VP R6 E VP R6 E VP R6 E VP R6 E VP R6 E VP R6 E VP R6 E VP R6 E VP R6 E

8/80 8/100 8/120 10/80 10/100 10/115 10/135 10/160 10/200

dnom x Lt mm

Øv x Lv mm

h1 mm

Tfix mm

d0 mm

hef mm

df mm

8x80 8x100 8x120 10x80 10x100 10x115 10x135 10x160 10x200

5,5x85 5,5x105 5,5x125 7x85 7x105 7x120 7x140 7x165 7x205

90 110 130 90 110 125 145 170 210

10 30 50 10 30 45 65 90 130

8 8 8 10 10 10 10 10 10

70 70 70 70 70 70 70 70 70

8 8 8 10 10 10 10 10 10

VP R6 E nylon frame fixing with Torx recess chipboard screw

Code

1287 1288 1289 1290 1291 1292 1293 1294 1295

Description

VP R6 ET VP R6 ET VP R6 ET VP R6 ET VP R6 ET VP R6 ET VP R6 ET VP R6 ET VP R6 ET

8/80 8/100 8/120 10/80 10/100 10/115 10/135 10/160 10/200

TX30 TX30 TX30 TX40 TX40 TX40 TX40 TX40 TX40

dnom x Lt mm

Øv x Lv mm

h1 mm

Tfix mm

d0 mm

hef mm

df mm

8x80 8x100 8x120 10x80 10x100 10x115 10x135 10x160 10x200

5,5x85 5,5x105 5,5x125 7x85 7x105 7x120 7x140 7x165 7x205

90 110 130 90 110 125 145 170 210

10 30 50 10 30 45 65 90 130

8 8 8 10 10 10 10 10 10

70 70 70 70 70 70 70 70 70

8 8 8 10 10 10 10 10 10

VP R6 IA2 nylon frame fixing with stainless steel chipboard screw

Code

Description

10000 10001 10002 10003 10004 10005 10006 10007

VP R6 I A2 VP R6 I A2 VP R6 I A2 VP R6 I A2 VP R6 I A2 VP R6 I A2 VP R6 I A2 VP R6 I A2

8/80 TX30 8/100 TX30 8/120 TX30 10/80 TX40 10/100 TX40 10/115 TX40 10/135 TX40 10/160 TX40

dnom x Lt mm

Øv x Lv mm

h1 mm

Tfix mm

d0 mm

hef mm

df mm

8x80 8x100 8x120 10x80 10x100 10x115 10x135 10x160

5,5x85 5,5x105 5,5x125 7x85 7x105 7x120 7x140 7x165

90 110 130 90 110 125 145 170

10 30 50 10 30 45 65 90

8 8 8 10 10 10 10 10

70 70 70 70 70 70 70 70

8 8 8 10 10 10 10 10

244

Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Hole diameter in the fixture dnom = Plug diameter hef = Effective embedment depth


universal and frame fixings

Vorpa VP R6

Nylon frame fixings with multiple wings

Concrete

Solid brick

Hollow brick

Natural stone

Technical data

VP R6 Z nylon frame fixing with hexagonal bolt screw

Code

1372 1373 1374 1375 378 379 1380 1381 1386

Description

VP R6 Z VP R6 Z VP R6 Z VP R6 Z VP R6 Z VPR6 Z VPR6 Z VPR6 Z VPR6 Z

8/80 8/100 8/120 10/80 10/100 10/115 10/135 10/160 10/200

dnom x Lt mm

Øv x Lv mm

h1 mm

Tfix mm

d0 mm

hef mm

df mm

Ch mm

8x80 8x100 8x120 10x80 10x100 10x115 10x135 10x160 10x200

5,5x85 5,5x105 5,5x125 7x90 7x105 7x120 7x140 7x165 7x205

90 110 130 90 110 125 145 170 210

10 30 50 10 30 45 65 90 130

8 8 8 10 10 10 10 10 10

70 70 70 70 70 70 70 70 70

8 8 8 10 10 10 10 10 10

10 10 10 13 13 13 13 13 13

VP R6 VSnylon frame fixing with safety Torx recess screw

Code

1390 1391 1392 1393 1994 1995

Description

VP R6 VS 10/90 VP R6 VS 10/100 VP R6 VS 10/115 VP R6 VS 10/135 VP R6 VS 10/160 VP R6 VS 10/200

TX40 TX40 TX40 TX40 TX40 TX40

dnom x Lt mm

Øv x Lv mm

h1 mm

Tfix mm

d0 mm

hef mm

df mm

10x80 10x100 10x115 10x135 10x160 10x200

7x90 7x105 7x120 7x140 7x165 7x205

105 115 125 145 170 210

10 30 45 65 90 130

10 10 10 10 10 10

70 70 70 70 70 70

10 10 10 10 10 10

Installation data Pull out values in daN Concrete C20/25 Solid brick Double brick UNI with plaster

1 daN ≃1 kg VP R6 Ø mm 8 380 300 120

VP R6 Ø mm 10 480 380 150

ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.

As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.

245

Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Hole diameter in the fixture dnom = Plug diameter hef = Effective embedment depth ch = Spanner


universal and frame fixings

Vorpa VP R8

Nylon fixings with multiple wings for frame and light carpentry

Concrete

Solid brick

Hollow brick

Natural stone

Products group Suitable for • Concrete • Solid brick • Hollow brick • Natural stone

VP R8 nylon plug

Examples of applications

To fix • Light carpentry • Wood coatings • Handrails • Wood substructures • Door frames • Window frames • Counter frames

VP R8 TE nylon plug with hexagonal bolt screw

VP R8 TSP nylon plug with chipboard screw

Installation sequence On compact materials

Make a drill hole with a hammer drill

Clean the hole

Place the fixture and then insert the anchor into the hole

Put the anchor by hammering softly on the screw head until the fixture stops the nylon plug

Make sure that the fixture is supported by the anchor (nylon plug and screw)

Clean the hole

Place the fixture and the anchor into the hole by hand

Put the anchor by hammering softly on the screw head until the fixture stops the nylon plug

Sent the screw by screw driver or by hand. Make sure that the fixture is supported by the anchor (nylon plug and screw)

On hollow materials

Make a drill hole just by rotary drilling

Product information Characteristics • Nylon plug for frames and light carpentry

Installation • Through setting anchors

Benefits • Guarantees a simple installation • Wide range of applications • Suitable for push-through installation • Plug with special anti-rotation wings • The higher lenght allows the anchor to contain the entire thickness of the element to be fastened

Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation

246


universal and frame fixings

Vorpa VP R8

Nylon fixings with multiple wings for frame and light carpentry

Concrete

Solid brick

Hollow brick

Natural stone

Technical data VP R8 nylon plug

Code

Description

d0 mm

h1 mm

Lt mm

Tfix mm

hef mm

df mm

screws mm

51386 51387 1571 1572 830S 586 51384 51385 51389

VP R8 VP R8 VP R8 VP R8 VP R8 VP R8 VP R8 VP R8 VP R8

10 10 12 12 16 16 16 16 16

255 295 215 255 155 175 215 255 320

240 280 200 240 140 160 200 240 300

140 180 100 140 40 60 100 140 200

100 100 100 100 100 100 100 100 100

11 11 13 13 17 17 17 17 17

7 7 10 10 12 12 12 12 12

10/240 10/280 12/200 12/240 16/140 16/160 16/200 16/240 16/300

VP R8 TE nylon plug with hexagonal bolt screw

Code

Description

52395 52396 1387 1388 1382 1383 1384 1385 52397

VP R8 TE VP R8 TE VP R8 TE VP R8 TE VP R8 TE VP R8 TE VP R8 TE VP R8 TE VP R8 TE

10/240 10/280 12/200 12/240 16/140 16/160 16/200 16/240 16/300

dnom x Lt mm

Øv x Lv mm

h1 mm

Tfix mm

hef mm

d0 mm

df mm

Ch mm

10x240 10x280 12x200 12x240 16x140 16x160 16x200 16x240 16x300

7x245 7x285 10x200 10x240 12x140 12x160 12x200 12x240 12x300

255 295 215 255 155 175 215 255 320

140 180 100 140 40 60 100 140 200

100 100 100 100 100 100 100 100 100

10 10 12 12 16 16 16 16 16

11 11 13 13 17 17 17 17 17

13 13 17 17 19 19 19 19 19

VP R8 TSP nylon plug with chipboard screw

Description

dnom x Lt mm

Øv x Lv mm

h1 mm

hef mm

Tfix mm

d0 mm

df mm

51395 VP R8 TSP 10/240 51396 VP R8 TSP 10/280

10x240 10x280

7x245 7x285

255 295

100 100

140 180

10 10

11 11

Code

Installation data Pull out values in daN Concrete C20/25 Solid brick Double brick UNI with plaster

1 daN ≃1 kg VP R8 Ø10 480 380 300

VP R8 Ø12 680 400 300

ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.

VP R8 Ø16 820 480

As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.

247

Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Hole diameter in the fixture dnom = Plug diameter hef = Effective anchorage depth ch = Spanner


universal and frame fixings

Vorpa VP A

Nylon frame fixings with multiple wings

Concrete

Solid brick

Natural stone

Products group VP A nylon frame plug with chipboards screw

Suitable for • Concrete • Solid brick • Natural stone

VP A nylon frame plug with A2 stainless steel screw Torx recess

To fix • Light carpentry • Wood coatings • Handrails • Wood substructures • Door frames • Window frames • Counter frames

Examples of applications

Installation sequence

Make a drill hole with a hammer drill

Clean the hole

Place the fixture and then insert the anchor into the hole

Put the anchor by hammering softly on the screw head until the fixture stops the nylon plug

Make sure that the fixture is supported by the anchor (nylon plug and screw)

Product information Characteristics • Nylon frame plug with wings for light carpentry and substructures fixings Benefits • The expanding portion has a limited length, the use is suggested mainly with solid materials • Guarantees a simple installation • Wide range of applications • Suitable for push-through installation • Plug with special anti-rotation wings • The higher lenght allows the anchor to contain the entire thickness of the element to be fastened

Installation • Through setting anchors Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation

248


universal and frame fixings

Vorpa VP A

Nylon frame fixings with multiple wings

Concrete

Solid brick

Natural stone

Technical data

VP A nylon frame plug with chipboards screw

Code

304 348 305 349 323 306 307 308 309 310

Description

dnom x Lt mm

Øv x Lv mm

h1 mm

Tfix mm

d0 mm

hef mm

df mm

VP A 6/60 VP A 8/60 VP A 8/80 VP A 8/100 VP A 8/120 VP A 10/80 VP A 10/100 VP A 10/115 VP A 10/135 VP A 10/160

6x60 8x60 8x80 8x100 8x120 10x80 10x100 10x115 10x135 10x160

4x65 5,5x65 5,5x85 5,5x105 5,5x125 7x85 7x105 7x120 7x140 7x165

70 70 90 110 130 95 115 130 150 175

30 20 40 60 80 30 50 65 85 110

6 8 8 8 8 10 10 10 10 10

30 40 40 40 40 50 50 50 50 50

7 9 9 9 9 11 11 11 11 11

VP A nylon frame plug with A2 stainless steel screw Torx recess

Code

4140 4141 4142 4143 4144 4145 4146 4147 4148

Description

dnom x Lt mm

Øv x Lv mm

h1 mm

Tfix mm

d0 mm

hef mm

df mm

VP A A2 VP A A2 VP A A2 VP A A2 VP A A2 VP A A2 VP A A2 VP A A2 VP A A2

8x60 8x80 8x100 8x120 10x80 10x100 10x115 10x135 10x160

5,5x65 5,5x85 5,5x105 5,5x125 7x85 7x105 7x120 7x140 7x165

70 90 110 130 95 115 130 150 175

20 40 60 80 30 50 65 85 110

8 8 8 8 10 10 10 10 10

40 40 40 40 50 50 50 50 50

9 9 9 9 11 11 11 11 11

8/60 TX30 8/80 TX30 8/100 TX30 8/120 TX30 10/80 TX40 10/100 TX40 10/115 TX40 10/135 TX40 10/160 TX40

Installation data Pull out values in daN Concrete C20/25 Solid brick

1 daN ≃1 kg VP A Ø6 200 150

VP A Ø8 340 300

ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.

VP A Ø10 420 350

As for applications on natural stones and solid bricks it is not possible to show specific loading valves because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.

249

Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness Øv = Screw diameter Lv = Screw length df = Hole diameter in the fixture dnom = Plug diameter hef = Effective embedment depth ch = Spanner


universal and frame fixings

Vorpa FSS-FSC

Through steel screw for windows frame

Concrete

Solid brick

Hollow brick

Aerated concrete

Products group To fix • Door frames • Window frames

Suitable for • Concrete • Solid brick • Hollow brick • Aerated concrete

FSS flat-head

FSC cylinder-head

Product information Characteristics • Special threaded steel screws Torx recess for window frames Benefits • Quick, easy, economical • Efficient work • No additional plugs are required for screw installation • The continuous thread prevents the window frame from being pulled against the substrate • Stress-free and long-lasting fixing of frame • The special thread reduces the amount of force required for screwing in the screws Installation sequence

Benefits • Cylinder-head screws are recommended for recessed installation in wooden profiles • Flat-head screws are recommended for installation in plastic and alluminium profiles Installation • To be mounted aligned the wall Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation Solid brick

Hollow brick

Technical data

FSS flat-head

Code

2410 2408 2428 2411 2412 2413 2414 2415 2416 2417 2418 2419 2420 2429

Description

FSS 7,5x42 FSS 7,5x52 FSS 7,5x62 FSS 7,5x72 FSS 7,5x82 FSS 7,5x92 FSS 7,5x102 FSS 7,5x112 FSS 7,5x122 FSS 7,5x132 FSS 7,5x152 FSS 7,5x182 FSS 7,5x212 FSS 7,5x302

d0 mm

h1 mm

Øv x Lv mm

Øt mm

Ch mm

6 6 6 6 6 6 6 6 6 6 6 6 6 6

55 65 75 85 95 105 113 125 133 145 165 195 225 315

7,5x42 7,5x52 7,5x62 7,5x72 7,5x82 7,5x92 7,5x102 7,5x112 7,5x120 7,5x132 7,5x152 7,5x182 7,5x212 7,5x302

10,8-11,3 10,8-11,3 10,8-11,3 10,8-11,3 10,8-11,3 10,8-11,3 10,8-11,3 10,8-11,3 10,8-11,3 10,8-11,3 10,8-11,3 10,8-11,3 10,8-11,3 10,8-11,3

T30 T30 T30 T30 T30 T30 T30 T30 T30 T30 T30 T30 T30 T30

250

h1 Lv Øv d 0 Øt ch

= Min. hole depth = Screw length = Screw diameter = Hole diameter = Head screw diameter = Spanner


universal and frame fixings

Vorpa FSS-FSC

Through steel screw for windows frame

Concrete

Solid brick

Hollow brick

Aerated concrete

Technical data

FSC cylinder-head

T15 Art.

T25 Art.

T30 Art.

Description

2457 2471 2472 2460 2458 2459 2461 2462 2463 2464 2465 2466 2467 2468 2469 2470

32458 32459 32461 32462 32463 32464 32465 32466 32467 32468 32469 32470 32471 32472

FSC 5x62 FSC 5x82 FSC 5x112 FSC 7,5x42 FSC 7,5x52 FSC 7,5x62 FSC 7,5x72 FSC 7,5x82 FSC 7,5x92 FSC 7,5x102 FSC 7,5x112 FSC 7,5x122 FSC 7,5x132 FSC 7,5x152 FSC 7,5x182 FSC 7,5x212 FSC 7,5x252 FSC 7,5x302

d0 mm

h1 mm

Øv x Lv mm

Øt T25 mm

Øt T30 mm

4 4 4 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6

72 92 120 55 65 75 85 95 105 113 125 135 145 165 195 225 265 315

5x62 5x82 5x112 7,5x42 7,5x52 7,5x62 7,5x72 7,5x82 7,5x92 7,5x102 7,5x112 7,5x120 7,5x132 7,5x152 7,5x182 7,5x212 7,5x252 7,5x302

7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70 7,50-7,70

8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5 8,0-8,5

Installation data Embedment depth

Concrete

Solid brick

Hollow brick doppio UNI

Light weight concrete

hef ≥ 30 mm

hef ≥ 40 mm

hef ≥ 60 mm

hef ≥ 60 mm

Installation data Pull out values in daN Concrete C20/25 Solid brick EN 771-2 Italian standard hollow brick with plaster (doppio UNI EN 771-1) Aerated concrete

1 daN ≃1 kg ≥ 30 mm 320 -

≥ 40 mm 320 -

ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values.

251

≥ 60 mm 160 80

h1 = Min. hole depth Lv = Screw length Øv = Screw diameter d0 = Hole diameter Øt = Head screw diameter ch = Spanner T15 = Torx Recess 15 T25 = Torx Recess 25 T30 = Torx Recess 30


universal and frame fixings

Vorpa VG A

Steel frame fixing with screw

Concrete

Solid brick

Hollow brick

Natural stone

Products group VG A with flat-head screw

VG A with cylinder-head screw

To fix • Facades • Window frames • Door frames

Suitable for • Concrete • Solid brick • Natural stone

Installation sequence

Product information Characteristics • Metal frame anchor with metric screw for window and door frames

Benefits • By tightening the screw, the cone is drawn into the sleeve and the fixing is expanded which wedges it inside the drill hole Installation • Through setting anchors

Benefits • Ensures a stress-free and long-lasting fixing of frame • The special plug geometry anchors the metal and plastic profiles Suggestion for use • Always consider an appropriate safety factor against compressive and tensile loads • Check load bearing capacity values • Suitable for push-through installation • Respect the installation data • Clean the hole before the installation Technical data

VG A with flat-head screw Code

2267 2270 2266 2273 2268 2274 2269 2275 2276 2277 2278 2279 2280

VG A with cylinder-head screw

Description

dnom x Lt mm

h1 mm

hef mm

Tfix mm

d0 mm

df mm

8x92 8x112 8x72 8x92 8x112 8x132 8x152 10x72 10x92 10x112 10x132 10x152 10x182

90 90 90 90 90 90 90 90 90 90 90 90 90

60 60 60 60 60 60 60 60 60 60 60 60 60

25 45 5 25 45 65 85 5 25 45 65 85 115

8 8 8 8 8 8 8 10 10 10 10 10 10

8 8 8 8 8 8 8 10 10 10 10 10 10

VG A VG A VG A VG A VG A VG A VG A VG A VG A VG A VG A VG A VG A

8/92 TSC * 8/112 TSC * 8/72 TSP 8/92 TSP 8/112 TSP 8/132 TSP 8/152 TSP 10/72 TSP 10/92 TSP 10/112 TSP 10/132 TSP 10/152 TSP 10/182 TSP

Installation data Pull out values in daN Materials Concrete C20/25 Solid brick

1 daN ≃1 kg VG A Ø8 280 -

VG A Ø10 530 500

ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values. 252

Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness df = Hole diameter in the fixture dnom = Plug diameter hef = Effective anchorage depth


universal and frame fixings

Vorpa VG N

Nylon frame fixing with screw

Concrete

Solid brick

Perforated brick

Hollow brick

Aerated Poroton

Products group To fix • Facades • Window frames • Door frames

Suitable for • Concrete • Solid brick • Perforated brick • Hollow brick • Aerated poroton • Perforated cement

Installation sequence

Product information Installation • Through setting anchors

Characteristics • Nylon frame anchor with metal screw for window and door frames Benefits • Ensures a stress-free and long-lasting fixing of frame • The special plug geometry anchors the metal and plastic profiles against compressive and tensile loads • Allows for a secure hold of the window frame • Suitable for push-through installation

Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation

Technical data

Code

266 273 268 274 275 276 277 278 279

Description

dnom x Lt mm

h1 mm

hef mm

Tfix mm

d0 mm

df mm

VG N 8/75 VG N 8/100 VG N 8/120 VG N 8/140 VG N 10/75 VG N 10/100 VG N 10/120 VG N 10/140 VG N 10/165

8x75 8x100 8x120 8x140 10x75 10x100 10x120 10x140 10x165

55 55 55 55 55 55 55 55 55

50 50 50 50 50 50 50 50 50

30 50 70 90 30 50 70 90 115

8 8 8 8 10 10 10 10 10

8 8 8 8 10 10 10 10 10

Installation data Pull out values in daN Materials Concrete C20/25 Solid brick Italian standard hollow brick with plaster (doppio UNI)

1 daN ≃1 kg VG N Ø8 300 280 80

VG N Ø10 520 480 120

ATTENTION: An appropriate safety factor ≥ 5 should be applied on these values. 253

Lt = Plug length h1 = Min. hole depth d0 = Hole diameter Tfix = Fixture thickness df = Hole diameter in the fixture dnom = Plug diameter hef = Effective anchorage depth


universal and frame fixings

Vorpa CLAPS

fixing in plastic material for fixing frames and subframes Products group to fix • Window and door frames • Subframes • Doors - windows

Product information Characteristics • Fixng in plastic material for fixing frames and subframes

Benefici • alette guida che si adattano al particolare del fissaggio • blocco garantito del CLAPS sul telaio • fornita in una striscia di quattro pezzi collegati fra loro • inserimento facilitato e veloce

Technical data

Code

1870 1871 1872

Description

CLAPS 2 CLAPS 3 CLAPS 5

Thickness mm

Colour

2 3 5

neutral grey black

Ls L S P D A B

= = = = = = =

40 32 8 4 ,5 36 18 9

mm mm mm mm mm mm mm

Installation sequence

Place the subframe.

Insert the fixing of plastic material at the point of the window in which the fixing will be carried out.

254

Once the fixation has been completed, remove the unused claps.


universal and frame fixings

Vorpa VSL Steel screws

Wood

Products group To fix • Outside fittings • Covering • Big structures • Wood carpentry

Suitable for • Wood

ribs under head no pre-countersinking

extra-deep torx bit

high quality surface treatment for fast and easy application

milling thread reducing risk of splitting

cutting edge

fast screw pitch successfully reduced labor time by 40%

European Technical Approval EAD 130118-00-0603

Examples of applications

255


universal and frame fixings

Vorpa VSL Steel screws

Wood

Product information Characteristics • Wood building screw , TORX recess

Installation • Through-setting and pre-setting fixing

Benefits • Drilling is not necessary • Suitable for permanent and removable fixings both inside and outside • High performances in wood • No risk to make slits on the wood thanks to the milling body • Special pre-drilling design • Quick pitch thread

Suggestions for use • Choose the right size of the screw according to the load • Always check load bearing capacity values in the table • Respect the installation data

Installation sequence

Technical data

Code

Description

93264 93265 93266 93267 93268 93269 93270 93271 93272 93273 93274 93275 93276 93277 93278 93279 93280 93281 93282 93283 93284

VSL 4 VSL 4 VSL 4 VSL 4 VSL 4 VSL 4 VSL 4 VSL 4,5 VSL 4,5 VSL 4,5 VSL 4,5 VSL 4,5 VSL 5 VSL 5 VSL 5 VSL 5 VSL 5 VSL 5 VSL 5 VSL 6 VSL 6

x x x x x x x x x x x x x x x x x x x x x

30 40 45 50 60 70 80 40 50 60 70 80 40 50 60 70 80 100 120 60 80

Lv mm

dv mm

h1 mm

Tfix max mm

Characteristic resistance kN

*Recommended load kN

Ch Torx

30 40 45 50 60 70 80 40 50 60 70 80 40 50 60 70 80 100 120 60 80

4 4 4 4 4 4 4 4,5 4,5 4,5 4,5 4,5 5 5 5 5 5 5 5 6 6

20 24 27 30 36 42 48 24 30 36 42 48 24 30 36 42 48 60 70 36 48

10 16 18 20 24 28 32 16 20 24 28 32 16 20 24 28 32 40 50 24 32

0,78 0,94 1,06 1,18 1,41 1,65 1,88 1,06 1,32 1,59 1,85 2,12 1,18 1,47 1,76 2,06 2,35 2,94 3,43 2,12 2,82

0,19 0,23 0,26 0,29 0,35 0,41 0,47 0,26 0,33 0,39 0,46 0,53 0,29 0,36 0,44 0,51 0,58 0,73 0,85 0,53 0,70

T20 T20 T20 T20 T20 T20 T20 T25 T25 T25 T25 T25 T25 T25 T25 T25 T25 T25 T25 T30 T30

256

Lv dv Tfix Ch

= Screw length = Screw diameter = Fixture thickness = Spanner (impronta Torx)

Safety factor applied = 4 1 Kn = 100 kg approx. 1 Kn = 100 kg


universal and frame fixings

Vorpa VSL Steel screws

Wood

Technical data

Code

Description

93285 93286 93287 93288 93289 93290 93291 93292 93293 93294 93295 93296 93297 93298 93299 93300 93301 93302 93303 93304 93305 93306 93307 93308 93309 93310 93311 93312 93313 93314 93315 93316 93317 93318 93319 93320 93321 93322 93323 93324 93325 93326 93327

VSL 6 VSL 6 VSL 6 VSL 6 VSL 6 VSL 6 VSL 6 VSL 6 VSL 6 VSL 6 VSL 6 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 8 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10 VSL 10

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

100 120 140 160 180 200 220 240 260 280 300 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400

Lv mm

dv mm

h1 mm

Tfix max mm

Characteristic resistance kN

*Recommended load kN

Ch mm

100 120 140 160 180 200 220 240 260 280 300 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400

6 6 6 6 6 6 6 6 6 6 6 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10

60 70 70 70 70 70 70 70 70 70 70 50 60 70 80 80 80 80 80 80 80 80 80 80 80 80 80 80 70 80 80 80 80 80 80 80 80 80 80 80 80 80 80

40 50 70 90 110 130 150 170 190 210 230 30 40 50 60 80 100 120 140 160 180 200 220 240 260 280 300 320 50 60 80 100 120 140 160 180 200 220 240 260 280 300 320

3,53 4,12 4,12 4,12 4,12 4,12 4,12 4,12 4,12 4,12 4,12 3,92 4,70 5,49 6,27 6,27 6,27 6,27 6,27 6,27 6,27 6,27 6,27 6,27 6,27 6,27 6,27 6,27 6,86 7,84 7,84 7,84 7,84 7,84 7,84 7,84 7,84 7,84 7,84 7,84 7,84 7,84 7,84

0,88 1,03 1,03 1,03 1,03 1,03 1,03 1,03 1,03 1,03 1,03 0,98 1,17 1,37 1,56 1,56 1,56 1,56 1,56 1,56 1,56 1,56 1,56 1,56 1,56 1,56 1,56 1,56 1,71 1,96 1,96 1,96 1,96 1,96 1,96 1,96 1,96 1,96 1,96 1,96 1,96 1,96 1,96

T30 T30 T30 T30 T30 T30 T30 T30 T30 T30 T30 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40 T40

257

Lv dv Tfix Ch

= Screw length = Screw diameter = Fixture thickness = Spanner (impronta Torx)

Safety factor applied = 4 1 Kn = 100 kg approx. 1 Kn = 100 kg


universal and frame fixings

Vorpa VSL M extra short type Wood building screws with cylinder flat head

Wood

products group Suitable for • wood

flat head Ø 1,6cm

high quality surface treatment for fast and easy application

cutting edge

milling thread reducing risk of splitting

extra-deep torx bit

To fix • Covering • Big structures • Wood carpentry

fast screw pitch successfully reduced labor time by 40%

Examples of applications

product information Characteristics • wood building screws with cylinder flat head extra short type for safe applications on pillars Benefits • Drilling is not necessary • Suitable for permanent and removable fixings both inside and outside • High performances in wood technical data

Code

Description

93451 93452 93453 93454

VSL M 8 x 40 VSL M 8 x 50 VSL M 8 x 60 VSL M 8 x 80

Benefits • No risk to make slits on the wood thanks to the milling body • Special pre-drilling design • Quick pitch thread • the extra short size of the screw with head diameter 1,6 cm ensures safe applications on pillars reducing number of screws to be used. • the flat head screw allows a perfect alignment to the metal plates; when fixing on pillars it can be used as normal screw but the larger diameter head permits optimal grip and better pressure distribution of the fasten.

Lv mm

dv mm

h1 mm

Tfixmax mm

Characteristic resistance kN

Recommended load kN

Ch Torx

8x40 8x50 8x60 8x80

8 8 8 8

30 35 40 50

10 15 20 30

1,80 2,40 3,10 3,92

0,45 0,60 0,77 0,98

40 40 40 40

258

Lv = Screw length dv = Screw diameter h1 = Min. hole depth tfix = Fixture thickness Ch = Torx + bit Safety factor applied = 4


Scaffolding anchors


scaffolding anchors

Vorpa TOP T

Steel anchors with eyebolt Ø 50 for scaffolds standing on the ground

Concrete

Solid brick

Natural stone

products group Suitable • concrete • solid brick • natural stone

To fix • scaffolding standing on the ground

Test report available

Software Vorpa Calcul Anchor Examples of applications

product information Characteristics • Torque controlled expansion anchor made of galvanized steel composed of anti-rotation cold formed body, expansion conical nut and eyebolt Ø 50 Benefits • The eyebolt can be used several times thanks to the anchor spare part • The cap hole covering enables to cover off holes at the end of the work in a quick and simple way • Eyebolt neck with flat slot to tight by wrench • Anti-rotation during the installation procedure

Benefits • Three-part expansion sleeve allows even load distribution and small edge and axial spacing Installation • To be mounted aligned the wall Suggestion for use • Make sure the scaffold and eyebolt are well positioned each other • Apply a proper safety factor according to the each situation • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

260


scaffolding anchors

Vorpa TOP T

Steel anchors with eyebolt Ø 50 for scaffolds standing on the ground

Concrete

Solid brick

installation sequence 1) installation procedure

Drill the masonry.

Clean the hole by using proper cleaning brushes and pump.

Insert the anchor in the hole. Screw the eyebolt applying the correct torque and set the washer aligned to the wall.

2) to re-use the eyebolt

Unscrew the eyebolt and pull it out.

Installation completed.

Close the hole with the proper cap.

technical data

Code

837 838

Description

d0 mm

Lt mm

h1 mm

Tinst mm

Øi mm

l mm

ch mm

TOP T 12/130 TOP T 12/180

18 18

130 180

140 190

75 75

50 50

100 100

22 22

art 713

art 91294

art 91057

art 1896

Code

Type

d0 mm

Lengt mm

713 91294 91057 1896

TOP 12 - Ø 18 Ø 18 steel washer Ø 18 steel spacer Cap hole covering

18

75

Sizes mm

C mm

18x45x3 18x54x2 18

75

22

Installation data Pull-out values in daN for applications on concrete C20/25 TOP T

1 daN ≃1 kg

4.500

ATTENTION: An appropriate safety factor ≥ 3 should be applied on these values. As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.

261

Øv = Internal eyebolt diameter l = Axial spacing h1 = Min. hole depth Lt = Anchor length d0 = Hole diameter Tinst = Torque ch = spanner

Natural stone


scaffolding anchors

Vorpa eyebolt VN

welded eyebolt for scaffolds standing on the ground

Concrete

Solid brick

Natural stone

gruppo prodotti Suitable for: • concrete • solid brick • natural stone VN P eyebolt Ø 23

To fix: • scaffolds standing on the ground • tensioning ropes • chains

Test reports available

VN PX eyebolt Ø 50

Examples of applications

product information Charateristics • Galvanized steel welded eyebolt to be used with nylon plugs. Suitable for scaffolds standing on the ground Benefits • The eyebolt can be used several times thanks to the anchor spare part • High load-bearing capacity is achieved by using it with the proper nylon fixing • The anchor grants safe and easy applications thanks to mark on the eyebolt stem enabling a right embedment depth during the anchoring

Benefits • Wide range of eyebolts for every requirement • The cap hole covering enables to cover off holes at the end of the work in a quick and simple way. Installation • To be mounted aligned with the mark on the eyebolt body Suggestions for use • Make sure the scaffold and the eyebolt are well positioned each other • Apply a proper safety factor according to the each situation • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

262


scaffolding anchors

Vorpa eyebolt VN

welded eyebolt for scaffolds standing on the ground

Concrete

Solid brick

Natural stone

installation sequence 1) Installation procedure

Drill the masonry.

Clean the hole by using proper cleaning brushes and pump.

Insert the nylon plug in the hole.

Screw the eyebolt applying the correct torque.

2) To re-use the eyebolt

Installation completed.

Unscrew the eyebolt and pull it out.

Close the hole with the proper cap.

technical data

VN P eyebolt Ø 23

Code

836 2837 2838 2834 2835 2836 2854 2855 2856

Description

VN P VN P VN P VN P VN P VN P VN P VN P VN P

12/120 12/160 12/190 12/230 12/300 12/350 12/400 12/450 12/500

d0 Ø mm

h1 mm

hef mm

ØvxLo mm

hef+l mm

Øtxlt mm

Ø mm

Tinst mm

14 14 14 14 14 14 14 14 14

115 115 115 115 115 115 115 115 115

100 100 100 100 100 100 100 100 100

12x120 12x160 12x190 12x230 12x300 12x350 12x400 12x450 12x500

145 185 215 255 325 375 425 475 525

14x100 14x100 14x100 14x100 14x100 14x100 14x100 14x100 14x100

23 23 23 23 23 23 23 23 23

19 19 19 19 19 19 19 19 19

VN P eyebolt Ø 50

Code

3836 3837 3838 3839

Description

VN PX 12/120 VN PX 12/160 VN PX 12/190 VN PX 12/230

d0 Ø mm

h1 mm

hef mm

ØvxLo mm

hef+l mm

Øtxlt mm

Ø mm

Tinst mm

14 14 14 14

115 115 115 115

100 100 100 100

12x120 12x160 12x190 12x230

155 200 240 265

14x100 14x100 14x100 14x100

50 50 50 50

19 19 19 19

263

Øv = Eyebolt diameter Lo = Eyebolt length I = Axial spacing hef = Min. anchorage depth h1 = Min. hole depth Lt = Anchor length d0 = Hole diameter Øt = Anchor diameter Tinst = Torque


scaffolding anchors

Vorpa eyebolt VN

welded eyebolt for scaffolds standing on the ground

Solid brick

spare parts

art 820 - 635R

Code

635R 820 2840

art 2840

Type

d0

VN 14/75 VN 14/100 CFP cap hole covering

14 14 12/14

Length mm

C mm

75 100 37

26

installation data Pull-out values in daN for applications on concrete C20/25 using a nylong plug VN 14/100

1 daN ≃1 kg

VN P / VN PX 1.300 ATTENTION: An appropriate safety factor > 5 should be applied on these values. As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.

264

Natural stone


scaffolding anchors

Vorpa eyebolt OS 8 Ø23

welded eyebolt for scaffolds standing on the ground

Concrete

Solid brick

Natural stone

products group Suitable for: • concrete • solid brick • natural stone

To fix: • scaffolds standing on the ground • tensioning ropes • chains

Insert the nylon plug in the hole.

Screw the eyebolt applying the correct torque and set the washer aligned to the wall.

eyebolt OS 8 Ø23

installation sequence 1) Installation procedure

Drill the masonry.

Clean the hole by using proper cleaning brushes and pump. 2) To re-use the eyebolt

Installation completed.

Unscrew the eyebolt and pull it out.

Close the hole with the proper cap.

product information Charateristics • Galvanized steel welded eyebolt to be used with nylon fixings Suitable for scaffolds standing on the ground Benefits • The eyebolt can be used several times thanks to the anchor spare part

Suggestions for use • Make sure the scaffold and the eyebolt are well positioned each other • Apply a proper safety factor according to the each situation • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

Installation • To be mounted aligned with the mark on the eyebolt body

265


scaffolding anchors

Vorpa eyebolt OS 8 Ø23

welded eyebolt for scaffolds standing on the ground

Concrete

Solid brick

technical data

eyebolt OS 8 Ø 23

Code

1990 1991 1992

Description

OS 8 Ø23 8/80 OS 8 Ø23 8/100 OS 8 Ø23 8/120

d0 Ø mm

h1 mm

hef mm

ØvxLo mm

hef+l mm

Øtxlt mm

Ø mm

Tinst mm

12 12 12

75 75 75

60 60 60

8x80 8x100 8x120

100 120 140

12x60 12x60 12x60

23 23 23

15 15 15

Øv = Eyebolt diameter Lo = Eyebolt length I = Axial spacing hef = Min. anchorage depth h1 = Min. hole depth Lt = Anchor length d0 = Hole diameter Øt = Anchor diameter Tinst = Torque

accessories

art 634

Art

634 2840

art 2840

Tipo

d0

VN 12/60 CFP cap hole covering

12 12/14

Length mm

C mm

60 37

26

installation data Pull-out values in daN for applications on concrete C20/25 using a nylong plug VN 12/60

1 daN ≃1 kg

OS 8 Ø23 1.020 ATTENTION: An appropriate safety factor > 5 should be applied on these values. As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department.

266

Natural stone


scaffolding anchors

Vorpa VSP P

steel anchors with eyebolt Ø 23 for scaffolds standing on the ground

Concrete

Solid brick

Natural stone

product group Suitable • concrete • solid brick • natural stone

To fix • scaffolds standing on the ground • tensioning ropes • chains

Test reports available Examples of applications

product information Characteristics • Galvanized steel welded eyebolt Ø 23 with VS-P or VSX expansion body

Benefits • High tensile loads with standard depth • The cap hole covering enables to cover off holes at the end of the work in a quick and simple way

Benefits • The eyebolt can be used several times thanks to the anchor spare part • The special nylon washer avoids the seepage of water through the external hole • The anchor grants safe and easy applications thanks to mark on the eyebolt stem enabling a right embedment depth during the anchoring • Smooth expansion thanks to the three cuts on the expansion body

Installation • To be mounted aligned with the mark on the eyebolt body Suggestion for use • Make sure the scaffold and the eyebolt are well positioned each other • Apply a proper safety factor according to the each situation • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

267


scaffolding anchors

Vorpa VSP P

steel anchors with eyebolt Ø 23 for scaffolds standing on the ground

Concrete

Solid brick

Natural stone

installation sequence 1) installation procedure

Drill the masonry.

Clean the hole by using proper cleaning brushes and pump.

Insert the anchor in the hole.

Screw the eyebolt applying the correct torque and set the washer aligned to the wall. Øv = Eyebolt internal diameter hef = Min. anchorage depth h1 = Min. hole depth d0 = Hole diameter tinst = Torque

Installation completed.

technical data

Code

9882 9880 881

Description

d0 mm

h1 mm

hef mm

axial spacing hef+l

Øi mm

expansion body M8

Tins mm

VSP P 12/130 VSP P 12/180 VSP P 12/215

12 12 12

80 95 85

80 80 80

130 180 215

23 23 23

12x45 12x55 12x45

25 25 25

spare parts Code

2833 3972 2840

d0 mm

Type

Washer 12x32x4 VSP 12 M8 CFP cap hole covering

12 12/14

Length mm

C mm

code 3972

37

26

Installation data

code 2840

Pull-out values in daN for applications on concrete C20/25 VSP P

code 2833

1 daN ≃1 kg

1.500

ATTENTION: An appropriate safety factor ≥ 3 should be applied on these values. As for applications on natural stones and solid bricks it is not possible to show specific loading values because of the various materials properties. It is suggested to always make pull out tests before using the anchors. For any particular need please contact Vorpa technical department. A too high torque moment during the installation may cause permanent deformations and even the breaking of the threaded part affecting the eyebolt resistance.

268


scaffolding anchors

Vorpa scaffold tester 25 kN product group Suitable • medium duty tester 25 kN tension for pull out tests on scaffolding anchors and chemical anchors

product information Characteristics • Tester with fixed gauge calibrated to 25 kN with maximum load indicator • Load spreading bridge feet granting the proper positioning in every situation • Compact and pratical, it grants safety and reliability • Strong rectangular stand • Maximum tensile load 25 kN • Calibration Certificate • Supplied in a Plastic Carrying Case • Weight 10 kg, dimension cm 55x39x14

technical data

accessories

Accessories Carrying case Code Code

Description

6500D

Tester 25 kN

Description

6517 25 kN analogic gauge 6518 25 kN digital gauge

Load gauge Indication of pull-out load Calibrated in kn Traceable calibration certificate supplied with each guage

Protective rubber cover Impact resistant glass Protection against sudden load relief (i.e. sudden failure of fixing)

Kit contents 25 kN Gauge Load Spreading Bridge with level bubbles Hex Legs with leg extension adjustment Swivel Feet M12 Locking Adaptor M12 Ringbolt Adaptor Clevis

Bolt Test Adaptor Threaded Stud Adaptor Operating Instructions Calibration Certificate Oil Bottle

269


scaffolding anchors

Vorpa mid heavy duty tester 50 kN product group Suitable • the new tester features a 50 kN (5 ton) analogue gauges as standard. Digital gauges are also available.

product information Characteristics • Medium duty tester 50kN tension for pull out tests on scaffolding anchors and chemical anchors. • Increased gauge scope - The new tester 50 kN tester features a 50kN(5 ton) analogue gauge as standard. Digital gauges are also available. • Turning handle - A new turning handle has been developed to accomodate the larger load. It offers a larger handle for ease of use and features an integrated M24 opearating nut for use with a ratchet spanner for operation in confined spaces. • Reinforced load spreading bridge - To sustain a 50kN load a new robust bridge design has been made which is denser in profile. It features three telescopic legs with pin arrangement in six positions and 30mm of fine adjustment at the base.

technical data

accessories

Accessories Kit tester 50kN Code Code

6511

Description

Description

• Analogic gauge 50 kN • Digital gauge 50 kN

Tester 50 kN

Kit contents Threaded Stud Adaptors New longer design M16, M20 and M24 as standard with optional M10, M12 and M30 Slotted Button Adaptors 6.8, 8.5, 10.5, and 12.5 as standard with optional 4.5 and 5.5

Threaded Button Adaptors M10 and M12 as standard with optional M4, M5, M6 and M8 Ringbolt Adaptor Clevis (optional) Rated to 50kN

270


scaffolding anchors

Vorpa scaffold tester 145kN products group Suitable The portable self-contained 145kN Heavy Duty Tester has been designed to meet the demand for proof load testing of larger construction fixings. A lightweight triangular shape aluminium load spreading bridge has been designed specifically for the model 145 kN tester and directs reaction loads away from the fixing, this combined with the tester weighs only 14kg. Load application is achieved via a ratchet handle driving a hydraulic multiplier and the applied load is recorded on a digital gauge which is integral with the tester. This compact design of tester and load spreading bridge is lighter and more convenient to apply than a separate hydraulic pump and cylinder arrangement.

product information Characteristics • Heavy duty tester 145 kN tension for pull out tests on heavy duty anchors and chemical anchors

technical data

Metal carrying case

Code

6502

Description

Scaffold Tester 145 kN

Kit contents Operating Nut Digital Gauge Load spreading Bridge with 10mm eye hook 3 adjustable legs with swivel feet 22mm Ratchet Spanner

5 Threaded Adaptors M12, M16, M20, M24, M30 Spirit Level Carry Case with Filler Operating Instructions Calibration Certificate

271


safety swing hook for antifalling

Vorpa AC M12 Hooks - wood hook safety hooks with steel anchors for anti-fall nets

Concrete

Solid brick

Natural stone

Boards and panels

Glulam GL24h

product group

art. 9315 Steel expansion body TOP M12 Ø18 ETA op.7

Suitable • concrete • solid brick • natural stone • boards and panels • wood lamella GL24h

art. 9316 Steel expansion body VHS M12 Ø16 ETA op.8

Tested by

Test report available AC M12 n° 3279510 In accordance with EN 1263

art. 9317 Steel expansion body VA CE M12 Ø15 ETA op. 7

art. 9331 Safety swing hook with 2 nuts and washer

Tested by art. 9322 Safety swing hook with wood screw

Test report available AC Ø10 n° 332232 Example of application

Product information Features • Safety hook with an innovative concept. The particular fold given to the hook ensures closure of the same, once the load of fall on the network it reaches the value of 700 daN on concrete and 450 daN on laminated wood Benefits • Possibility to insert and unfasten the fall prevention cable on the hook once made the fixing • The hook is recovered once the work is finished • High loadability thanks to the adaptation of the eyelet to the anchor • Wide selection of expanding bodies • Wide range of assortment of hooks and anchors

Suggestion for use • Choose the most suitable accessory in relation the application to carry out • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

272


safety swing hook for antifalling

Vorpa AC M12 Hooks - wood hook safety hooks with steel anchors for anti-fall nets

Concrete

Solid brick

Natural stone

installation sequence installation sequence for AC TOP Ø18

installation sequence for AC VA CE Ø15

technical data

B

art. 9315 mechanical anchor TOP M12 Ø18 assesment for non-cracked concrete

Code

Description

9315 AC TOP Ø18

Lt mm

do mm

h1 mm

I mm

Thread mm

A B C mm

Tinst Nm

75

18

85

80

M12

26 - 160 - 13

50

A

C

C = passage of the rope

art. 9316 mechanical anchor VHS M12 Ø16 assesment for non-cracked concrete

B

A

Code

Description

9316 AC VHS Ø16

Lt mm

do mm

h1 mm

I mm

Thread mm

A B C mm

Tinst Nm

70

16

80

80

M12

26 - 160 - 13

40

C

C = passage of the rope

art. 9317 mechanical anchor VA CE M12 Ø15 assesment for non-cracked concrete

Code

Description

9317 AC VA CE Ø15

Lt mm

do mm

h1 mm

I mm

Thread mm

A B C mm

Tinst Nm

50

15

55

75

M12

26 - 140 - 13

35

C = passage of the rope

273

B

A

C


safety swing hook for antifalling

Vorpa AC M12 Hooks - wood hook safety hooks with steel anchors for anti-fall nets

Boards and panels

technical data B Tfix

art. 9331 safety hook with nuts and washers

A

C

Code

9331

Description

AC M12 DR

Thread mm

L Thread mm

I mm

H1 mm

Tfix max mm

A B C mm

M12

65

75

55

35

22 - 140 - 13

C = passage of the rope

Example of application

accessories Code

Description

screws Ø mm

d0 mm

Lt mm

h1 mm

TOP M12 Ø18

713

TOP 12

M12

18

75

85

VHS M12 Ø16

51160

VHS 12

M12

16

70

80

VA M12 Ø15

99593

VA CE 12

M12

15

50

55

VA F M12 Ø15 with neck

98594

VA F CE 12

M12

15

50

55

299

PERCUSSION TOOL FOR ANCHOR 99593 - 98594

technical data Concrete C20/25 Determination of the resistance at the safety hook opening M12 with anchor VORPA AC M12

720 daN

Notice: the hook (1) is closed at the indicated load. The complete opening of the hook is determined at the maximum load of 1500 daN (2) 1) Behavior of the hook with pull-out up to 720 daN

2) Behavior of the hook with pull-out 1500 daN

274

1 daN ≃1 kg


safety swing hook for antifalling

Vorpa AC L Ø10 hooks

safety hooks with steel anchors for anti-fall nets

Glulam GL24h

technical data

ØD

art. 9322 safety hook for application on wood structures

Code

Description

9322

hnom do1 x h1 do2 x h2 mm Øxmm Øxmm

70

AC LEGNO Ø10

Ø7x70

Ø10x15

Test reports available

hmin mm

L Thread mm

ØD mm

A B C mm

80

45

10

22 - 160 - 13

C = passage of the rope hmin B A do2 do1 h2

do1 x h1 = do2 x h2 = hmin = hnom = L filetto = ØD =

Pre-hole diameter x length Second pre-hole diameter x length Minimum thickness in the wood/beam Minimum embedment in the beam Thread length Stem of the hook

C

h1 hnom

Example of application

installation sequence ACL hook on wooden material 70 mm

15 mm

Ø7

Pre hole with drill Ø7

Ø10

Pre hole with drill Ø10

Thighten up to the dark

Insert the cable into the hook

technical data 1 daN ≃1 kg Determination of the resistance on laminated wood GL 24h

700 daN

Use a safety factor ≥3 275


safety swing hook for antifalling

Vorpa AC M12 Hooks - wood hook safety swing hook for anti falling net

Concrete

Solid brick

Natural stone

Boards and panels

Glulam GL24h

installation sequence Correct sequence

1) Standing in front of the hook, grab the net with both hands and place it under the hook opening.

2) The part of the network, held by the right hand, must enter the open hook on the left.

3) Hold the net with both hands pulling the ends to facilitate the move into the hook.

4) The network has entered into the hook. proceed to the next hook.

5) The network is entered correctly into the support hooks

Wrong sequence

NO

NO

1) The network is placed in front of the hook opening. NO

2) The network is placed behind the opening of the hook. NO

276


safety swing hook for antifalling

Vorpa ACR M12 safety hook safety hooks with steel anchors for anti-fall nets

Concrete

product group

Solid brick

Natural stone

Boards and panel

Example of application Steel expansion body TOP CE

Steel expansion body VA CE

With 2 nuts and washer

Suitable • concrete • solid brick • natural stone • boards and panels • prestressed concrete plates with honeycomb core

Tested by

Test report available

Product information Characteristics • System composed of a steel curly hook and steel anchor for ropes and anti-falling nets on pillars, beams and solid walls Benefits • Possibility to insert and unfasten the fall prevention cable on the hook once made the fixing • The hook is recovered once the work is finished

Suggestion for use • Choose the most suitable accessory in relation the application to carry out • Choose the right size of the anchor according to the load • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

installation sequence ACR TOP on solid material

ACR VA on thin solid brick

277


safety swing hook for antifalling

Vorpa ACR M12 safety hook safety hooks with steel anchors for anti-fall nets

Concrete

Solid brick

Natural stone

Boards and panel

technical data

Steel expansion body TOP CE

Code

Description

9340 ACR M12 TOP 18 9326 ACR M10 TOP 14

d0 Lt Ø mm mm

18 14

75 60

h1 mm

l Thread Øg mm mm mm

85 70

55 40

Øi mm

M12 10,7 13 M10 9 13

Lg mm

Tins Nm Lt = Anchor length h1 = Min. hole depth d0 = Hole diameter Øg = Stem of the hook Øi = Passage of the rope Lg = Total length of the hook l = Axial spacing Tinst = Torque

150 50 135 30

Steel expansion body VA CE

Lg

Description

Lt mm

d0 mm

h1 mm

l Thread Øg mm mm mm

9341 ACR M12 VA 15

50

15

55

55

Code

Øi mm

Lg mm

Tins Nm

M12 10,7 13 110

35

Example of application With 2 nuts and washer

Code

Description

9342 ACR DR M12 hook

Thread length mm

Thread mm

I mm

42

M12

55

Øg mm

Lg mm

Øi mm

10,7

110

13

accessories Code

Description

for screws Ø mm

d0 mm

Lt mm

h1 mm

713 712

TOP 12 TOP 10

M12 M10

18 14

75 60

85 70

593

VA M12 Ø15

M12

15

50

55

technical data 1 daN ≃1 kg

Determination of the resistance at the safety hook ACR M12 TOP - ACR M12 VA ACR M10 TOP

600 daN 350 daN 278


safety swing hook for antifalling

Vorpa BEAM clamp for anti-falling fixings Clamp for anchoring to beams for the fixing of hooks for anti-falling nets

Iron beams IPE structures

product group Suitable for • iron beams • IPE structures • Metal carpentry

To fix • threaded accessories M8/M10/M12 • tensioning ropes • fall protection nets • industrial plant engineering • conducting installations, plumbing and drains

technical data Code

Description

A mm

B mm

C mm

D mm

E mm

F mm

G mm

H mm

Max load anchor point kg

Certification

89004 9335 9336

Steel clamp M 8 Steel clamp M10 Steel clamp M12

21 23 35

19 21 23,5

35 42 54

M8 M10 M12

35 41 48

M8 M10 M10

18 20 26

38 44 58

120 250 350

Vds - UL VdS - UL - FM VdS - UL - FM

Steel clamp with through threaded hole and hedgehog safety hook M10

Steel clamp with through threaded hole and M12 safety hook

examples of application

279


Fixings for insulation


fixings for insulation

Vorpa VP L 60 e 95 insulation panels fixings

Polystyrene Extruded panels polystyrene

products group Suitable • Polystyrene panels • Extruded polystyrene • Heat insulating and soundproofing panels

VP L 60

To fix • Plumbing and light flues • External wall lighting • Shop-signs and traffic-signs • Postboxes

Ideal for applications on compact masonry covered by heat insulating panels and rigid insulation materials whose minimum thickness is 60 mm.

VP L 95

product information Charateristics • Nylon light fixing to be used on masonry covered by rigid insulating panels

Installation • To be mounted aligned with the insulation panels by screwing and without pre-drilling

Benefits • Made of chemical agents resistant and paintable nylon • Easy and quick installation by T40 bit or hexagonal head screw M8 • No need to pre-drill • Ideal also for applications on ETICS systems • Ideal to fix rigid insulation materials whose minimum thickness is 60mm • Possibility to remove the object to maintenance without compromise the anchoring resistance • The fixing material prevents the thermal bridge phenomenon, avoiding heat waste.

Suggestions for use • In order to prevent the seepage of water in the insulation material, the plug’s edge must be sealed with acrylic sealant or silicone after the installation has been completed • When VPL fixing is mounted aligned with the insulation panels, the object to be fixed must be anchored by: - VPL 60: frame screw Ø 4,5 or 5,5 mm - VPL 95: metrical screw M8 and Ø 8 and 10 mm

installation sequence

Point the fixing on the masonry

Screw by using a drill without pre-drilling

Screw the frame screw inside VP L fixing

Examples of applications

Examples of applications

281

Installation completed


fixings for insulation

Vorpa VP L 60 e 95 insulation panels fixings

Polystyrene Extruded panels polystyrene

technical data

Code

4521

Description

Lt mm

bit

screw ø mm

screw length mm

S mm

VP L 60

58

Torx T40

4,5 - 5,5

30 + Tfix

≥ 60

M

Ø Lv

dv xLv mm

Thread

To be used on

4x40 5,5x40*

M6 M8

VPL 60 VPL 60

Code

Description

92224 92273

Screw M6x40 Screw M8x40

Code

Description

Lt mm

bit

screw ø mm

screw length mm

S mm

VP L 95

97

hex. head screw 13

M8 Ø 8-10

40 + Tfix

≥ 100

4522

Accessories VP L 95

Hexagonal bolt screw

Hexagonal bolt wood screw

Double thread screw

installation technical data Installation conditions

Base material thickness Min insertion of the screw in the plug Max insertion of the screw in the plug

VPL 60 mm ≥ 60 mm 30 mm 50

VPL 95 mm ≥ 100 mm 40 mm 80 1 daN ≃ 1 kg

Recommended loads daN Fixing type Base material Polystyrene PS 15 Polystyrene PS 20

VPL 60

VPL 95

4,0 5,0

9,0 10,0

282

Lt = Anchor length Tfix = Fixture thickness S = Insulation material thickness dv = Screw diameter Lv = Screw length


fixings for insulation

Vorpa PVC spacer

PVC spacer for fastenings on insulated walls product group Suitable for • thermal panels • acoustic panels • glass wool panel

To fix • brackets • profiles • fixings on coated walls • threaded bars

Examples of application

Fixing on hollow material with perforated sleeve

Product information Characteristics • PVC spacer for fastenings • Rigid and soft panels, to be used as support fixing for traditional systems • Fixing with threaded bars, chemical anchors on coated walls

Code

1163 1164 Code

1225 1226 1227 1228 Code

1229 1230 1231 1232

• Various lenghts available 1 meter, 10 mm, 30 mm, 50 mm, 100 mm

L mm

external diameter

internal hole diameter

Threaded bar Ø mm

1000 1000

35 45

15 20

12-14 16-20

Description

L mm

external diameter

internal hole diameter

Threaded bar Ø mm

PVC spacer Ø35x10 PVC spacer Ø35x30 PVC spacer Ø35x50 PVC spacer Ø35x100

10 30 50 100

35 35 35 35

15 15 15 15

12-14 12-14 12-14 12-14

Description

L mm

external diameter

internal hole diameter

Threaded bar Ø mm

PVC spacer Ø45x10 PVC spacer Ø45x30 PVC spacer Ø45x50 PVC spacer Ø45x100

10 30 50 100

45 45 45 45

20 20 20 20

16-20 16-20 16-20 16-20

Description

PVC spacer Ø35x1000 PVC spacer Ø45x1000

283

• Pierce wall and insulation panel • Pierce the insulation panel Ø35 o Ø45 as the desired PVC spacer


fixings for insulation PANELS

Vorpa ISO CE 8 NYLON

Light fixings for insulation panels with European Technical Assesment

Polystyrene panels

BASE MATERIALS

Concrete

Aerated concrete blocks

Lightweight aggregate blocks

Solid bricks Clay bricks

Hollow bricks

Product group Approved for • Concrete • Aerated concrete blocks • Lightweight aggregate blocks • Solid bricks / Clay bricks • Hollow bricks

To fix • Polystyrene panels • Extruded polystyrene

Ideal for applications on masonry coated by solid heat insulating panels and insulation materials. ETAG 014

A-B-C-D-E

Examples of applications

Examples of applications

Product information Characteristics • Polyamide fixing with fiberglass reinforced polyamide pin for all types of solid insulation materials. Use categories A-B-C-D-E.

Benefits • Product with European Technical Approval for use materials categories A-B-C-D-E

Benefits • Reduced thermal transfer • Easy and quick installation, the expansion is carried out by hammering the pin inside the nylon fixing • Reduced embedment depth enables reduced drilling times • Special washer Ø 140 permits the fixing on lightweight insulation materials • Special fiberglass reinforced polyamide pin

Installation • To be mounted aligned the wall Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • When calculating the usable length it is suggested to take into consideration eventual extra thicknesses such as glues, sealants, old plasters

Installation sequence

Wait till the sealant between the insulation panel and the base material is completely dry

Drill the base material with an appropriate drill bit

Insert the nylon fixing without pin until the washer rests again the insulation

284

Fix the pin by hammering gently until full expansion, i.e. when the head is leveled with washer surface


fixings for insulation PANELS

Vorpa ISO CE 8 NYLON

Light fixings for insulation panels with European Technical Assesment

BASE MATERIALS

Concrete

Polystyrene panels

Aerated concrete blocks

Lightweight aggregate blocks

Solid bricks Clay bricks

Hollow bricks

Technical data

Code

5775 5776 5777 5778 5779 5780

Description

Lt d0 mm mm

ISO CE 8 NY 8/95 ISO CE 8 NY 8/115 ISO CE 8 NY 8/135 ISO CE 8 NY 8/155 ISO CE 8 NY 8/175 ISO CE 8 NY 8/195

95 115 135 155 175 195

1) = Use categories A.B,C,D 2) = Use category E

8 8 8 8 8 8

h1 mm

hef mm

Tfix mm

≥351)/≥752) ≥351)/≥752) ≥351)/≥752) ≥351)/≥752) ≥351)/≥752) ≥351)/≥752)

≥251)/≥652) ≥251)/≥652) ≥251)/≥652) ≥251)/≥652) ≥251)/≥652) ≥251)/≥652)

Lt-hef-Ttol Lt-hef-Ttol Lt-hef-Ttol Lt-hef-Ttol Lt-hef-Ttol Lt-hef-Ttol

P mm

T T T T T T

+T +T +T +T +T +T

ØT dp Lnp b mm mm mm mm

+h +h +h +h +h +h

fix

tol

ef

fix

tol

ef

fix

tol

ef

fix

tol

ef

fix

tol

ef

fix

tol

ef

60 60 60 60 60 60

4,8 4,8 4,8 4,8 4,8 4,8

100 120 140 160 180 200

44 44 44 44 44 44

hmin = 100 mm Cmin = 100 mm Smin = 100 mm

Ancillaries

Code

Description

ØT mm

55762

ISO DISCO CE 140

140

Installation data Pull out values in daN Materials C12/15 concrete C16/20 - C50/60 concrete Clay bricks / calcium silicate bricks Calcium Silicate hollow blocks Vertically perforated clay bricks Porotherm 25 Lightweight aggregate concrete blocks LAC Autoclaved aerated concrete elements AAC2 Autoclaved aerated concrete elements AAC7

1 daN ≃1 kg Class A A B C C C D E E

Density Kg/dm3 ≥ 2.25 ≥ 2.30 ≥ 2.00 ≥ 1.60 ≥ 1.20 ≥ 0.80 ≥ 0.88 ≥ 0.35 ≥ 0.65

daN 50 75 75 75 60 40 60 75 90

Characteristic loading values according to ETA Recommended safety factor = 2 ETAG 014 light fixings Use category A B C D E

Building materials Normal weight concrete Solid masonry - Silicate blocks Hollow or perforated masonry Lightweight aerated concrete Autoclave aerated concrete

285

Lt = Anchor length h1 = Min. hole depth d0 = Hole diameter hef = Embedment depth Tfix = Fixture thickness P = Total depth of holes dp = Pin diameter Lnp = Pin length b = Pin’s knurling length Ttol = Thickness of equalizing and/ or non-load-bearing layer hmin = Min. base material thickness Smin = Min. anchor spacing Cmin = Min. edge distance


fixings for insulation PANELS

Vorpa ISO CE 8

Light fixings for insulation panels with European Technical Assesment

Mineral wool lamella

Mineral wool

BASE MATERIALS

Polystyrene panels

Extruded polystyrene

Concrete

Aerated concrete blocks

Lightweight aggregate blocks

Solid bricks Clay bricks

Hollow bricks

Product group Approved for • Concrete • Aerated concrete blocks • Lightweight aggregate blocks • Solid bricks / Clay bricks • Hollow bricks

To fix • Mineral wool lamella /mineral wool • Polystyrene panels • Extruded polystyrene

Ideal for applications on masonry coated by heat insulating panels and insulation materials. ETAG 014

A-B-C-D-E

Examples of applications

Examples of applications

Product information Characteristics • Polyamide fixing with white galvanized steel pin with head coated with plastic suitable for all types of insulation materials. Use categories A-B-C-D-E. Benefits • Reduced thermal transfer due to plastic endings of metal pin • Easy and quick installation, the expansion is carried out by hammering the pin inside the nylon fixing • Reduced embedment depth enables reduced drilling times • Special washer Ø 140 permits the fixing on lightweight insulation materials • Pin’s head covered by fiberglass reinforced polyamide

Benefits • Product with European Technical Approval for use materials categories A-B-C-D-E • The steel pin is suitable for all types of insulation materials and particularly for rigid insulation materials Installation • To be mounted aligned the wall Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • When calculating the usable length it is suggested to take into consideration eventual extra thicknesses such as glues, sealants, old plasters

Installation sequence

Wait till the sealant between the insulation panel and the base material is completely dry

Drill the base material with an appropriate drill bit

Insert the nylon fixing without pin until the washer rests again the insulation

286

Fix the pin by hammering gently until full expansion, i.e. when the head is leveled with washer surface


fixings for insulation PANELS

Vorpa ISO CE 8

Light fixings for insulation panels with European Technical Assesment

Mineral wool lamella

Mineral wool

BASE MATERIALS

Polystyrene panels

Concrete

Extruded polystyrene

Aerated concrete blocks

Lightweight aggregate blocks

Solid bricks Clay bricks

Hollow bricks

Technical data

Code

5747 5748 5749 5750 5751 5752

Description

Lt mm

d0 mm

h1 mm

hef mm

Tfix mm

P mm

ISO CE 8 8/95 ISO CE 8 8/115 ISO CE 8 8/135 ISO CE 8 8/155 ISO CE 8 8/175 ISO CE 8 8/195

95 115 135 155 175 195

8 8 8 8 8 8

≥351)/≥752) ≥351)/≥752) ≥351)/≥752) ≥351)/≥752) ≥351)/≥752) ≥351)/≥752)

≥251)/≥652) ≥251)/≥652) ≥251)/≥652) ≥251)/≥652) ≥251)/≥652) ≥251)/≥652)

Lt - hef - Ttol Lt - hef - Ttol Lt - hef - Ttol Lt - hef - Ttol Lt - hef - Ttol Lt - hef - Ttol

Tfix+Ttol+hef Tfix+Ttol+hef Tfix+Ttol+hef Tfix+Ttol+hef Tfix+Ttol+hef Tfix+Ttol+hef

1) = Use categories A.B,C,D 2) = Use category E

ØT dp Lnp mm mm mm

60 60 60 60 60 60

4,8 4,8 4,8 4,8 4,8 4,8

100 120 140 160 180 200

hmin = 100 mm Cmin = 100 mm Smin = 100 mm

Ancillaries

Code

Description

ØT mm

55762

ISO DISCO CE 140

140

Installation data Pull out values in daN Materials C12/15 concrete C16/20 - C50/60 concrete Clay bricks / calcium silicate bricks Calcium Silicate hollow blocks Vertically perforated clay bricks Porotherm 25 Lightweight aggregate concrete blocks LAC Autoclaved aerated concrete elements AAC2 Autoclaved aerated concrete elements AAC7

1 daN ≃1 kg Class A A B C C C D E E

Density Kg/dm3 ≥ 2.25 ≥ 2.30 ≥ 2.00 ≥ 1.60 ≥ 1.20 ≥ 0.80 ≥ 0.88 ≥ 0.35 ≥ 0.65

daN 50 75 75 75 60 40 60 75 90

Characteristic loading values according to ETA Recommended safety factor = 2 ETAG 014 light fixings Use category A B C D E

Building materials Normal weight concrete Solid masonry - Silicate blocks Hollow or perforated masonry Lightweight aerated concrete Autoclave aerated concrete

287

Lt = Anchor length h1 = Min. hole depth d0 = Hole diameter hef = Embedment depth Tfix = Fixture thickness P = Total depth of holes dp = Pin diameter Lnp = Pin length Ttol = Thickness of equalizing and/ or non-load-bearing layer hmin = Min. base material thickness Smin = Min. anchor spacing Cmin = Min. edge distance


fixings for insulation PANNE PANELS LLI

Vorpa ISO CE 10 MF

Light fixings for insulation panels with European Technical Assesment

Polystyrene panels

BASE MATERIALS

Silica bricks class 15

Solid clay bricks

Perforated bricks

Product group Approved for • Silica bricks class 15 • Solid bricks / Clay bricks • Perforated bricks

Use categories B-C

To fix • Polystyrene panels • Rigid insulation panels

Ideal for applications on masonry coated by heat insulating panels and rigid insulation materials

Examples of applications

Examples of applications

Product information Characteristics • Polyamide fixing with pin made of fiberglass reinforced polyamide suitable for the fixing of rigid insulation panels on perforated and compact materials. Use categories B-C Benefits • Reduced thermal transfer • Easy and quick installation, the expansion is carried out by hammering the pin inside the nylon fixing • Reduced embedment depth enables reduced drilling times • Pin made of fiberglass reinforced polyamide • Particularly indicated to fix rigid insulation materials • Product with European Technical Approval for use materials categories B-C

Installation • To be mounted aligned the wall Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • When calculating the usable length it is suggested to take into consideration eventual extra thicknesses such as glues, sealants, old plasters, etc.

288


fixings for insulation PANNE PANELS LLI

Vorpa ISO CE 10 MF

Light fixings for insulation panels with European Technical Assesment

Polystyrene panels

BASE MATERIALS

Silica bricks class 15

Solid clay bricks

Perforated bricks

Installation sequence

Wait till the sealant between the insulation panel and the base material is completely dry

Drill the base material with an appropriate drill bit

Insert the nylon fixing without pin until the washer rests again the insulation

Fix the pin by hammering gently until full expansion, i.e. when the head is leveled with washer surface

Technical data

Code

5755 5756 5757 5758 5759 5760 5761

Description

Lt d0 h1 hef mm mm mm mm

ISO CE MF 10 10/140 ISO CE MF 10 10/160 ISO CE MF 10 10/180 ISO CE MF 10 10/200 ISO CE MF 10 10/220 ISO CE MF 10 10/260 ISO CE MF 10 10/300

140 160 180 200 220 260 300

10 10 10 10 10 10 10

90 90 90 90 90 90 90

80 80 80 80 80 80 80

Tfix mm

P mm

ØT mm

dp mm

Lnp mm

b mm

S mm

Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef

Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1

60 60 60 60 60 60 60

5,3 5,3 5,3 5,3 5,3 5,3 5,3

140 160 180 200 220 260 300

85 85 85 85 85 85 85

10 10 10 10 10 10 10

hmin = 100 mm Cmin = 100 mm Smin = 100 mm

Installation data Pull out values in daN Materials Clay bricks Perforated ceramics blocks

1 daN ≃1 kg Class B C

Density Kg/dm3 ≥ 1.61 ≥ 1.17

daN 60 50

Characteristic loading values according to ETA Recommended safety factor = 2 ETAG 014 light fixings Use category A B C D E

Building materials Normal weight concrete Solid masonry - Silicate blocks Hollow or perforated masonry Lightweight aerated concrete Autoclave aerated concrete

289

Lt = Anchor length h1 = Min. hole depth d0 = Hole diameter hef = Embedment depth Tfix = Fixture thickness P = Total depth of holes dp = Pin diameter Lnp = Pin length b = Pin’s knurling length Ttol = Thickness of equalizing and/ or non-load-bearing layer hmin = Min. base material thickness Smin = Min. anchor spacing Cmin = Min. edge distance


fixings for insulation PANELS

Vorpa ISO CE 10 MC

Light fixings for insulation panels with European Technical Assesment

Polystyrene panels

BASE MATERIALS

Concrete

Aerated concrete blocks

Lightweight aggregate blocks

Solid bricks Clay bricks

Product group Approved for • Concrete • Aerated concrete • Lightweight aggregate blocks • Solid bricks / Clay bricks

Use categories A-B-C-D-E

To fix • Polystyrene panels • Rigid insulation panels

Ideal for applications on compact masonry coated by heat insulating panels and rigid insulation materials

Examples of applications

Examples of applications

Product information Characteristics • Polyamide fixing with pin made of fiberglass reinforced polyamide suitable for the fixing of rigid insulation panels on compact materials. Use categories A-B-C-D-E Benefits • Reduced thermal transfer • Easy and quick installation, the expansion is carried out by hammering the pin inside the nylon fixing • Reduced embedment depth enables reduced drilling times • Pin made of fiberglass reinforced polyamide • Product with European Technical Approval for use materials categories A-B-C-D-E

Installation • To be mounted aligned the wall Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • When calculating the usable length it is suggested to take into consideration eventual extra thicknesses such as glues, sealants, old plasters, etc.

290


fixings for insulation PANELS

Vorpa ISO CE 10 MC

Light fixings for insulation panels with European Technical Assesment

BASE MATERIALS

Concrete

Polystyrene panels

Aerated concrete blocks

Lightweight aggregate blocks

Solid bricks Clay bricks

Installation sequence

Wait till the sealant between the insulation panel and the base material is completely dry

Drill the base material with an appropriate drill bit

Insert the nylon fixing without pin until the washer rests again the insulation

Fix the pin by hammering gently until full expansion, i.e. when the head is leveled with washer surface

Technical data

Code

Description

Lt d0 mm mm

5765 5766 5767 5768 5769 5770 5771 5772 5773 5774

ISO CE MC 10 10/70 ISO CE MC 10 10/90 ISO CE MC 10 10/110 ISO CE MC 10 10/120 ISO CE MC 10 10/140 ISO CE MC 10 10/160 ISO CE MC 10 10/180 ISO CE MC 10 10/200 ISO CE MC 10 10/220 ISO CE MC 10 10/260

70 90 110 120 140 160 180 200 220 260

1) = Use categories A.B,C,D 2) = Use category E

10 10 10 10 10 10 10 10 10 10

h1 mm

hef mm

Tfix mm

P mm

≥401/≥602 ≥401/≥602 ≥401/≥602 ≥401/≥602 ≥401/≥602 ≥401/≥602 ≥401/≥602 ≥401/≥602 ≥401/≥602 ≥401/≥602

≥301/≥502 ≥301/≥502 ≥301/≥502 ≥301/≥502 ≥301/≥502 ≥301/≥502 ≥301/≥502 ≥301/≥502 ≥301/≥502 ≥301/≥502

Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef Lt-Ttol-hef

Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1

ØT dp Lnp b mm mm mm mm

60 60 60 60 60 60 60 60 60 60

5,5 5,5 5,5 5,5 5,5 5,5 5,5 5,5 5,5 5,5

75 95 115 125 145 165 185 205 225 265

44 44 44 44 44 44 44 44 44 44

hmin = 100 mm Cmin = 100 mm Smin = 100 mm

Installation data Pull out values in daN Materials C12/15 concrete C20/25 - C50/60 concrete Clay bricks Calcium silicate solid brick Calcium silicate hollow blocks Vertically perforate clay bricks Porotherm 25 Lightweight aggregate concrete solid blocks Autoclaved aerated concrete blocks AAC2 Autoclaved aerated concrete blocks AAC7

1 daN ≃1 kg Class A A B B C C C D E E

Density Kg/dm3 ≥ 2.25 ≥ 2.30 ≥ 2.00 ≥ 2.00 ≥ 1.60 ≥ 1.20 ≥ 0.80 ≥ 0.88 ≥ 0.35 ≥ 0.65

daN 50 75 75 60 60 60 40 60 50 60

Characteristic loading values according to ETA Recommended safety factor = 2 ETAG 014 light fixings Use category A B C D E

Building materials Normal weight concrete Solid masonry - Silicate blocks Hollow or perforated masonry Lightweight aerated concrete Autoclave aerated concrete

291

Lt = Anchor length h1 = Min. hole depth d0 = Hole diameter hef = Embedment depth Tfix = Fixture thickness P = Total depth of holes dp = Pin diameter Lnp = Pin length b = Pin’s knurling length Ttol = Thickness of equalizing and/ or non-load-bearing layer hmin = Min. base material thickness Smin = Min. anchor spacing Cmin = Min. edge distance


fixings for insulation PANELS

Vorpa ISO TL

Light fixings for insulation panels with European Technical Assesment

Mineral wool lamella

Mineral wool

Polystyrene panels

BASE MATERIALS

Extruded polystyrene

Concrete

Solid bricks Clay bricks

Hollow bricks

Product group Approved for • Concrete • Solid bricks / Clay bricks • Hollow bricks ISO TL Lt ≤ 130 mm

To fix • Mineral wool lamella • Mineral wool • Polystyrene panels • Extruded polystirene

Ideal for applications on masonry covered by heat insulating panels and rigid and soft insulation materials Use categories A-B-C ISO TL Lt ≥ 150 mm

ETAG 014

A-B-C

Examples of applications

Examples of applications

Product information Characteristics • Polyethylene fixing with fiberglass reinforced nylon PA6 pin suitable to fix rigid and soft insulation materials on hollow and compact materials. Use categories A-B-C Benefits • Reduced thermal transfer granting energy saving • Easy and quick installation, the expansion is carried out by hammering the pin inside the nylon fixing • Special fiberglass reinforced polyamide pin granting more resistance to the fixing

Installation • To be mounted aligned the wall Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • When calculating the usable length it is suggested to take into consideration eventual extra thicknesses such as glues, sealants, old plasters

292


fixings for insulation PANELS

Vorpa ISO TL

Light fixings for insulation panels with European Technical Assesment

Mineral wool lamella

Mineral wool

BASE MATERIALS

Polystyrene panels

Extruded polystyrene

Concrete

Solid bricks Clay bricks

Hollow bricks

Installation sequence

Wait till the sealant between the insulation panel and the base material is completely dry

Drill the base material with an appropriate drill bit

Insert the nylon fixing without pin until the washer rests again the insulation

Fix the pin by hammering gently until full expansion, i.e. when the head is leveled with washer surface

Technical data

ISO TL Lt ≤ 130 mm Code

5744 655 656 657 658 * 740 748 752 5745 5746

ISO TL Lt ≥ 150 mm

Description

Lt mm

d0 mm

h1 mm

hef mm

Tfix mm

P mm

ØT mm

dp mm

Lnp mm

Sp mm

ISO TL ISO TL ISO TL ISO TL ISO TL ISO TL ISO TL ISO TL ISO TL ISO TL

60 70 90 110 120 130 150 180 210 240

10 10 10 10 10 10 10 10 10 10

40 40 40 40 40 40 40 40 40 40

30 30 30 30 30 30 30 30 30 30

30+Ttol 40+Ttol 60+Ttol 80+Ttol 90+Ttol 100+Ttol 120+Ttol 150+Ttol 180+Ttol 210+Ttol

Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1

53 53 53 53 53 53 58 58 58 58

5,3 5,3 5,3 5,3 5,3 5,3 5,6 5,6 5,6 5,6

68 68 68 88 108 128 148 178 210 238

2,6 2,6 2,6 2,6 2,6 2,6 2,6 2,6 2,6 2,6

10/60 10/70 10/90 10/110 10/120 10/130 10/150 10/180 10/210 10/240

*Not covered by ETA

Installation data Pull out values in daN Materials Concrete C20/25 Concrete C50/60 Solid brick/Clay brick Hollow brick

1 daN ≃1 kg Classe materiale A A B C

Density Kg/dm3 ≥ 2.30 ≥ 2.40 ≥ 2.00 ≥ 0.95

daN 39 42 47 22

Characteristic loading values according to ETA recommended safety factor = 2 ETAG 014 light fixings Use category A B C D E

Building materials Concrete Solid bricks Hollow bricks Lightweight aerated concrete Lightweight aggregate blocks

293

Lt = Anchor length h1 = Min. hole depth d0 = Hole diameter hef = Embedment depth Tfix = Fixture thickness P = Total depth of holes dp = Pin diameter Lnp = Pin length Sp = Head thickness Ttol = Thickness of equalizing and/ or non-load-bearing layer


fixings for insulation PANELS

Vorpa ISO

Light fixings for insulation panels with European Technical Assesment

Polystyrene panels

BASE MATERIALS

Extruded polystyrene

Concrete

Natural stone

Solid bricks

Product group To fix • Concrete • Natural stone • Solid bricks

Suitable for • Polystyrene panels • Extruded polystyrene • Rigid insulation panels

Ideal for applications on masonry covered by heat insulating panels and rigid and soft insulation materials Product information Installation • To be mounted aligned the wall

Characteristics • Polypropylene fixing without pin suitable to fix rigid insulation materials on compact materials. Benefits • Reduced thermal transfer • Easy and quick installation • Different lengths available grants the possibility to be used with different panels thickness • The anchoring is carried out by the thread compression inside the hole on compact material

Suggestion for use • Always consider an appropriate safety factor • Check load bearing capacity values • Respect the installation data • When calculating the usable length it is suggested to take into consideration eventual extra thicknesses such as glues, sealants, old plasters

Product group

Wait till the sealant between the insulation panel and the base material is completely dry

Drill the base material with an appropriate drill bit

Insert the nylon fixing without pin until the washer rests again the insulation

Technical data

Code

650 651 660 652 733 734 5736

Description

Lt mm

d0 mm

h1 mm

hef mm

Tfix mm

P mm

ØT mm

Sp mm

ISO 8/50 ISO 8/70 ISO 8/80 ISO 8/90 ISO 8/110 ISO 8/130 ISO 8/160

50 70 80 90 110 130 160

8 8 8 8 8 8 8

40 40 40 40 40 40 40

30 30 30 30 30 30 30

20-Ttol 40-Ttol 50-Ttol 60-Ttol 80-Ttol 100-Ttol 130-Ttol

Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1 Tfix+Ttol+h1

35 35 35 35 35 35 35

2,6 2,6 2,6 2,6 2,6 2,6 2,6

Installation data Pull out values in daN

1 daN ≃1 kg daN 40 20 15 15

Materials Concrete C20/25 Solid brick Perforated clay blocks and partitions Italian standard hallow brick with plaster

recommended safety factor = 3 294

Lt = Anchor length h1 = Min. hole depth d0 = Hole diameter hef = Embedment depth Tfix = Fixture thickness P = Total depth of holes dp = Pin diameter Lnp = Pin length Sp = Head thickness Ttol = Thickness of equalizing and/ or non-load-bearing layer


Cladding and pipe fixings


cladding and pipe fixings

Vorpa IF-IFO

Isophonic pipe clamp for iron and Polyethylene pipes (EPDM RUBBER) M8-M10 thread

Concrete

Natural stone

Products group Suitable for • Concrete • Natural stone • Solid brick pipe clamp IF with rubber and plastic plug

pipe clamp IFO with rubber

To fix • Industrial plants • High temperature exhaust fumes • High temperature liquid discharge

Examples of applications

Installation sequence

Product information Characteristics • Isophonic pipe clamps with EPDM rubber and wall plastic plug

Benefits • Temperature range -40°C ÷ +100°C • Fire resistance DIN 4109-B2

Benefits • Two screws allows for easy adjustment to suit the outer pipe diameter • Combination nut with thread M8/M10 • The sound insulation rubber offers noise protection and avoids contact corrosion • Screws safety feature • Wall nylon plug VN with anti-rotation wings

Suggestion for use • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

296

Solid brick


cladding and pipe fixings

Vorpa IF-IFO

Isophonic pipe clamp for iron and Polyethylene pipes (EPDM RUBBER) M8-M10 thread

Concrete

Natural stone

Solid brick

Technical data

pipe clamp IFO with rubber Code

Description

nominal diameter

ExD

A-B mm

M thread

side screws

2699 2700 2701 2702 2703 2704 2705 2706 2707 2708 2709 2710 2711 2712 2713 2714 2715 2716 2718S 2718 2719

IFO 12-15 IFO 15-19 IFO 20-25 IFO 26-30 IFO 32-36 IFO 38-43 IFO 47-51 IFO 53-58 IFO 60-64 IFO 68-72 IFO 76-80 IFO 81-86 IFO 87-92 IFO 99-105 IFO 107-112 IFO 113-118 IFO 125-130 IFO 135-140 IFO 159-166 IFO 168-172 IFO 200-212

1/4 3/8 1/2 3/4 1” 1” 1/4 1” 1/2 53-58 2” 68-72 2” 1/2 81-86 3” 3” 1/2 107-112 4” 125-130 5” 159-166 6” 200-212

19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 20x2,3 20x2,3 20x2,3 20x2,3 20x2,3 20x2,3 20x2,3

9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16 9-16

M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10 M8/M10

M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20

Code

Description

nominal diameter

ExD

d0xLt mm

h1 mm

M x Lp mm

side screws

4699 4700 4701 4702 4703 4704 4705 4706 4707 4708 4709 4710 4711 4712 4713 4714 4715 4716 4717S 4717 4718

IF 12-15 IF 15-19 IF 20-25 IF 26-30 IF 32-36 IF 38-43 IF 47-51 IF 53-58 IF 60-64 IF 68-72 IF 76-80 IF 81-86 IF 87-92 IF 99-105 IF 107-112 IF 113-118 IF 125-130 IF 135-140 IF 159-166 IF 168-172 IF 200-212

1/4 3/8 1/2 3/4 1” 1” 1/4 1” 1/2 53-58 2” 68-72 2” 1/2 81-86 3” 3” 1/2 107-112 4” 125-130 5” 159-166 6” 200-212

19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 19x1,8 20x2,3 20x2,3 20x2,3 20x2,3 20x2,3 20x2,3 20x2,3

10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60 10x60

80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80

M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90

M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20

297

1” 1/2

d0 = Hole diameter h1 = Min. hole depth Lt = Anchor length Lp = Pin length ExD = Width x thickness M = Thread

Installation data 1daN ≃ 1 Kg Pipes sizes 1/4 - 3” 1/2 107 - 212

pipe clamp IF with rubber and pladtic plug

Axial recommended load 180 daN 250 daN


cladding and pipe fixings

Vorpa BRM-BRG Steel clamps for steel pipes

Concrete

Natural stone

Solid brick

Products group Characteristics • Steel clamps with nylon plug for steel pipes

To fix • Industrial plants • Plumbing and heating systems • Run water vapor systems

Suitable for • Concrete • Natural stone • Solid brick

Technical data d0 = Hole diameter h1 = Min. hole depth Lt = Anchor length Lp = Pin length ExD = Width x thickness M = Thread

BRG steel pipe clamps

Code

4472 4474 4476 4477 4478 4479 4480 4481 4482 4483 4484 4485 4486 4487 4488

Description

BRG 16-20 BRG 20-24 BRG 25-30 BRG 32-36 BRG 38-44 BRG 46-50 BRG 58-62 BRG 74-80 BRG 82-89 BRG 112-118 BRG 74-80 BRG 82-89 BRG 112-118 BRG 130-141 BRG 164-172

nominal diameter

ExD

C mm

M thread

side screws

3/8 1/2 3/4 1” 1” 1/4 1” 1/2 2” 2” 1/2 3” 4” 2” 1/2 3” 4” 5” 6”

20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5

8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

M8 M8 M8 M8 M8 M8 M8 M8 M8 M8 M10 M10 M10 M10 M10

M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25

Installation data 1daN ≃ 1 Kg Pipes sizes 3/8 - 6”

BRM steel clamp with nylon plug and double threaded screw Code

1210 1211 1212 1213 1214 1215 1216 1217 1218 1219 1220 1221 1222 1223 1224

Description

BRM 16-20 BRM 20-24 BRM 25-30 BRM 32-36 BRM 38-44 BRM 46-50 BRM 58-62 BRM 74-80 BRM 82-89 BRM 112-118 BRM 74-80 BRM 82-89 BRM 112-118 BRM 130-141 BRM 164-172

nominal diameter

ExD mm

d0 x Lt mm

h1 mm

M x Lp mm

side screws

3/8 1/2 3/4 1” 1” 1/4 1” 1/2 2” 2” 1/2 3” 4” 2” 1/2 3” 4” 5” 6”

20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 20x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5

10 x 60 10 x 60 10 x 60 10 x 60 10 x 60 10 x 60 10 x 60 10 x 60 10 x 60 10 x 60 12 x 60 12 x 60 12 x 60 12 x 60 12 x 60

80 80 80 80 80 80 80 80 80 80 80 80 80 80 80

M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M10x120 M10x120 M10x120 M10x120 M10x120

M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25

298

BRM steel clamp with plastic plug and double threaded screw

Axial recommended load 250 daN


cladding and pipe fixings

Vorpa VRM - VR inox A2

A2 stainless steel clamp for iron pipes, flues, air ducts

Concrete

Natural stone

Solid brick

Products group Suitable for • Concrete • Natural stone • Solid brick

VRM inox A2 stainless steel clamp with wall plastic plug and double threaded screw

To fix • Industrial plants • Plumbing and heating systems • Run water vapor systems • coastal areas • food industries • plants on farms • sewage plants • shipyards plants

VR A2 stainless steel clamp

Examples of applications

Product information Characteristics • A2 stainless steel clamps for iron pipes, flues, air ducts and exhaust fumes outside

Suggestion for use • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

Benefits • The A2 stainless steel diameter prevents corrosive aggressions • Ideal for fixing on solid substrates

299


cladding and pipe fixings

Vorpa VRM - VR inox A2

A2 stainless steel clamp for iron pipes, flues, air ducts

Concrete

Natural stone

Solid brick

Technical data

VR A2 stainless steel clamp Code

3410 3411 3412 3413 3414 3415 3416 3417 3418 3421 3419 3420 3422 3423 3427 3424 3428 3425 3426 3429 3430

Code

3210 3211 3212 3213 3214 3215 3216 3217 3218 3222 3219 3220 3221 3223 3227 3224 3228 3225 3226

Description

VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX VR INOX

Description

16-20 18-24 25-30 30-36 38-44 44-50 56-62 76-80 90-100 100-110 110-120 125-130 140-150 152-160 180 200 220 250 300 350 400

nominal diameter

ExD

M thread

side screws

3/8 1/2 3/4 1” 1” 1/4 1” 1/2 2” 2” 1/2 3” 100-110 4” 125-130 5” 6” 180 200 220 250 300 350 400

20x1,5 20x1,8 20x1,8 20x1,8 20x1,8 20x1,8 20x1,8 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 30x1,5 30x1,5 30x1,5 30x1,5 30x2 30x2

M8 M8 M8 M8 M8 M8 M8 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10

6x20 6x20 6x20 6x20 6x20 6x20 6x20 6x30 6x40 6x40 6x40 6x40 6x40 6x40 6x30 6x30 6x30 6x30 6x30 6x30 6x30

nominal diameter

ExD

VRM INOX 16-20 3/8 20x1,5 VRM INOX 18-24 1/2 20x1,8 VRM INOX 25-30 3/4 20x1,8 VRM INOX 30-36 1” 20x1,8 VRM INOX 38-44 1” 1/4 20x1,8 VRM INOX 44-50 1” 1/2 20x1,8 VRM INOX 56-62 2” 20x1,8 VRM INOX 76-80 2” 1/2 24x1,5 VRM INOX 90-100 3” 24x1,5 VRM INOX 100-110 100-110 24x1,5 VRM INOX 110-120 4” 24x1,5 VRM INOX 125-130 125-130 24x1,5 VRM INOX 140-150 5” 24x1,5 VRM INOX 152-160 6” 24x1,5 VRM INOX 180 180 24x1,5 VRM INOX 200 200 30x1,5 VRM INOX 220 220 30x1,5 VRM INOX 250 250 30x1,5 VRM INOX 300 300 30x1,5

d0 x Lt mm

h1 mm

M x Lp mm

side screws

10 x 60 10 x 60 10 x 60 10 x 60 10 x 60 10 x 60 10 x 60 12 x 60 12 x 60 12 x 60 12 x 60 12 x 60 12 x 60 12 x 60 12 x 60 12 x 60 12 x 60 12 x 60 12 x 60

80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80

M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M8x90 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120

6x20 6x20 6x20 6x20 6x20 6x20 6x20 6x30 6x40 6x40 6x40 6x40 6x40 6x40 6x30 6x30 6x30 6x30 6x30

300

d0 = Hole diameter h1 = Min. hole depth Lt = Anchor length Lp = Pin length ExD = Width x thickness Ø = Pipe M = Thread

Installation data 1daN ≃ 1 Kg Pipes sizes 3/8 1/2-2” 2/1/2”-300 350-400

Axial recommended load 700 daN 800 daN 700 daN 800 daN

VRM inox A2 stainless steel clamp with wall plastic plug and double threaded screw


cladding and pipe fixings

Vorpa CAV - CAV inox A2

Steel clamp with anchor for iron pipes and flues

Concrete

Natural stone

Solid brick

Products group Suitable for • Concrete • Natural stone • Solid brick

CAV steel clamp with AV anchor, welded nut and double threaded screw

CAV inox A2 stainless steel clamp with stainless steel TOP anchor, welded nut and double threaded screw

To fix • Industrial plants • Plumbing and heating systems • Run water vapor systems

Examples of applications

Installation sequence

Product information Characteristics • Steel clamp for iron pipes, flues, exhaust fumes Benefits • The A2 stainless steel material prevents corrosive aggressions • Suitable for application in food sector • Ideal for fixing on solid substrates

Suggestion for use • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

301


cladding and pipe fixings

Vorpa CAV - CAV inox A2

Steel clamp with anchor for iron pipes and flues

Concrete

Natural stone

Solid brick

Technical data

CAV steel clamp with AV anchor, welded nut and double threaded screw

Art.

451 452 453 454 450 455 456 458 457 1457 459 1459 1460 1461

Description

CAV 50 CAV 63 CAV 2” 1/2 CAV 3” CAV 100 CAV 4” CAV 125 CAV 5” CAV 6” CAV 180 CAV 200 CAV 220 CAV 250 CAV 300

nominal diameter

ExD mm

d0 x Lt mm

h1 mm

M x Lp mm

side screws

50 63 2” 1/2 3” 100 4” 125 5” 6” 180 200 220 250 300

30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5

16 x 65 16 x 65 16 x 65 16 x 65 16 x 65 16 x 65 16 x 65 16 x 65 16 x 65 16 x 65 16 x 65 16 x 65 16 x 65 16 x 65

75 75 75 75 75 75 75 75 75 75 75 75 75 75

M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110

M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25

Installation data 1daN ≃ 1 Kg Pipes sizes 50 - 300

Axial recommended load 180 daN

CAV inox A2 stainless steel clamp with stainless steel TOP anchor, welded nut and double threaded screw

Art.

3540 3541 3542 3543 3544 3545 3546 3553 3554 3555 3556 3557 3558 3559 3563 3560 3564 3561 3562 3565 3566

Description

CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX CAV INOX

16-20 18-24 25-30 30-36 38-44 44-50 56-62 76-80 90-100 100-110 110-120 125-130 140-150 152-160 180 200 220 250 300 350 400

nominal diameter

ExD mm

d0 x Lt mm

h1 mm

M x Lp mm

side screws

3/8 1/2 3/4 1” 1” 1/4 1” 1/2 2” 2” 1/2 3” 100-110 4” 125-130 5” 6” 180 200 220 250 300 350 400

20x1,5 20x1,8 20x1,8 20x1,8 20x1,8 20x1,8 20x1,8 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 30x1,5 30x1,5 30x1,5 30x1,5 30x2 30x2

12 x 51 12 x 51 12 x 51 12 x 51 12 x 51 12 x 51 12 x 51 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60 14 x 60

60 60 60 60 60 60 60 70 70 70 70 70 70 70 70 70 70 70 70 70 70

M8x100 M8x100 M8x100 M8x100 M8x100 M8x100 M8x100 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110 M10x110

M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x30 M6x40 M6x40 M6x40 M6x40 M6x40 M6x40 M6x30 M6x30 M6x30 M6x30 M6x30 M6x30 M6x30

302

d0 = Hole diameter h1 = Min. hole depth Lt = Anchor length Lp = Pin length ExD = Width x thickness M = Thread

Installation data 1daN ≃ 1 Kg Pipes sizes 3/8 - 400

Axial recommended load 120 daN


cladding and pipe fixings

Vorpa CAV - P

Steel clamp with anchor for iron pipes and flues

Concrete

Products group Suitable for • Concrete • Solid brick To fix • Plumbing and heating systems

CAV steel clampa with AV anchors

Installation sequence

Product information Suggestion for use • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

Characteristics • Plumbing and heating systems

Code

Description

390 391 392 393 394 395 396

CAV-P 3/8 CAV-P 1/2 CAV-P 3/4 CAV-P 1” CAV-P 1/4 CAV-P 1/2 CAV-P 2”

nominal diameter

ExD mm

d0 x Lt mm

h1 mm

M

side screws

3/8 1/2 3/4 1” 1” 1/4 1” 1/2 2”

22 x 1,8 24 x 2,0 24 x 2,0 24 x 2,2 24 x 2,2 24 x 2,2 24 x 2,2

12 x 47 14 x 55 14 x 55 14 x 55 14 x 55 14 x 55 16 x 65

55 65 65 65 65 65 75

M6 M8 M8 M8 M8 M8 M10

M6x16 M6x16 M6x16 M6x16 M6x16 M6x16 M6x16

Installation data 1daN ≃ 1 Kg Pipes sizes 3/8 - 2”

Axial recommended load 120 daN

d0 = Hole diameter h1 = Min. hole depth Lt = Anchor length Lp = Pin length ExD = Width x thickness M = Thread

303

Solid brick


cladding and pipe fixings

Vorpa CDS GAS - VRP - CDG Steel clamps for PVC and Polyethylene pipes

Concrete

Natural stone

Solid brick

Products group To fix • Industrial plants • Plumbing and heating systems • Run water vapor systems

Suitable for • Concrete • Natural stone • Solid brick

CDS steel clamp with 1/2” welded nut

Examples of applications

VRP steel clamp with wall plastic plug and double threaded screw

CDG steel clamp with welded nut

Product information Suggestion for use • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before installation

Characteristics • Steel clamps for PVC and Polyethylene pipes

Technical data

CDS steel clamp with 1/2” welded nut ExD = Width x thickness

Code

1779 781 782 783 784 757 785 786 788 787 789 793 758 758S

Description

CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS CDS 1/2 GAS

40 50 63 76-80 90-100 100-110 110-120 125-130 140-150 152-160 200 250 300 315

nominal diameter

ExD mm

M thread

side screws

40 50 63 76 - 2”1/2” 90 - 3” 100 - 110 4” 125 - 130 5” 6” 200 250 300 315

30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5 30x2,5

1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2”

M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6

304

Installation data 1daN ≃ 1 Kg Pipes sizes 40 - 315

Axial recommended load 300 daN


cladding and pipe fixings

Vorpa CDS GAS - VRP - CDG Steel clamps for PVC and Polyethylene pipes

Concrete

Natural stone

Solid brick

Technical data

CDG steel clamp with welded nut

Code

1480 481 482 483 484 476 485 486 488 487 1487 489 1489 1490 1491

Description

nominal diameter

ExD mm

M thread

side screws

40 50 63 76 90 100 110 125 140 160 180 200 220 250 300

24x2,0 24x2,2 24x2,2 24x2,2 24x2,2 24x2,2 24x2,2 24x2,2 30x2,2 30x2,2 30x2,2 30x2,2 30x2,2 30x2,2 30x2,2

M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10

M6x20 M6x20 M6x20 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25

CDG 40 CDG 50 CDG 63 CDG 76 CDG 90 CDG 100 CDG 110 CDG 125 CDG 140 CDG 160 CDG 180 CDG 200 CDG 220 CDG 250 CDG 300

d0 = Hole diameter h1 = Min. hole depth Lt = Anchor length Lp = Pin length ExD = Width x thickness M = Thread

Installation data 1daN ≃ 1 Kg Pipes sizes 40 - 300 VRP steel clamp with wall plastic plug and double threaded screw

Code

4460 461 462 463 464 460 465 466 468 467 1470 469 1471 470 471

Description

nominal diameter

ExD mm

d0x Lt mm

h1 mm

Lp mm

side screws

VRP 40 VRP 50 VRP 63 VRP 76 VRP 90 VRP 100 VRP 110 VRP 125 VRP 140 VRP 160 VRP 180 VRP 200 VRP 220 VRP 250 VRP 300

40 50 63 76 90 100 110 125 140 160 180 200 220 250 300

24x2,0 24x2,2 24x2,2 24x2,2 24x2,2 24x2,2 24x2,2 24x2,2 30x2,2 30x2,2 30x2,2 30x2,2 30x2,2 30x2,2 30x2,2

12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60 12x60

75 75 75 75 75 75 75 75 75 75 75 75 75 75 75

M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120 M10x120

M6x20 M6x20 M6x20 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25

305

Axial recommended load 180 daN


cladding and pipe fixings

Vorpa CFI inox A2

A2 stainless steel clamps for flues and air ducts

Concrete

Solid brick

Perforated brick

Aerated poroton

Perforated cement

Products group Suitable for • Concrete • Solid brick • Perforated brick • Aerated poroton • Perforated cement

To fix • Flues • Air ducts • Industrial plants • Run water vapor system • Exhaust fumes • Smoking pipes

Examples of applications

d0 h1 Lt Lp

Product information

= Hole diameter = Min. hole depth = Anchor length = Pin length

Suggestion for use • Always check load bearing capacity values in the table • Respect the installation data • Clean the hole before the installation

Characteristics • A2 stainless steel clamps for flues and air ducts Benefits • The A2 stainless steel material prevents corrosive aggressions • Suitable for application in food sector • Ideal for fixing on solid substrates Technical data CFZ collare in acciaio A2 con tassello e vite di congiunzione Code

2771 2772 2773 2774 2775 2776 2777 2778 2779 2780 2781

Description

nominal diameter

ExD mm

d0 x Lt mm

CFI INOX 76-80 CFI INOX 100 CFI INOX 110-120 CFI INOX 125-130 CFI INOX 140-150 CFI INOX 160 CFI INOX 180 CFI INOX 200 CFI INOX 220 CFI INOX 250 CFI INOX 300

76-80 100 110-120 125-130 140-150 160 180 200 220 250 300

24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 30x1,5 30x1,5 30x1,5 30x1,5 30x1,5

10 x 80 10 x 80 10 x 80 10 x 80 10 x 80 10 x 80 12 x 74 12 x 74 12 x 74 12 x 74 12 x 74

Li = Axial spacing ExD = Width x thickness Ø = Pipes M = Thread

h1 mm

85 85 85 85 85 85 85 85 85 85 85

306

M x Lp mm

Li mm

side screws

M 8x200 M 8x200 M 8x200 M 8x200 M 8x200 M 8x200 M 10x180 M 10x180 M 10x180 M 10x180 M 10x180

158 170 175 182 190 200 210 220 230 245 270

M6x30 M6x30 M6x40 M6x40 M6x40 M6x30 M6x30 M6x30 M6x30 M6x30 M6x30


cladding and pipe fixings

Vorpa CFZ

White or black plastic-coated steel clamp for flues, air ducts, smoking pipes

Concrete

Solid brick

Perforated brick

Poroton

Products group Suitable for • Concrete • Solid brick • Perforated brick • Poroton • Perforated cement

To fix • Air ducts • Flues • Smoking pipes

Examples of applications

d0 h1 Lt Lp

ExD = Width x thickness Ø = Pipe Li = Axial spacing M = Thread

= Hole diameter = Min. hole depth = Anchor length = Pin length

Product information Characteristics • White or black plastic-coated steel clamp for flues, air ducts, smoking pipes Technical data White plastic-coated Code

2406 800 794 2485 2486 2488 2487

Description

nominal diameter

ExD mm

d0 x Lt mm

h1 mm

M x Lp mm

Li mm

side screws

CFZ 60 CFZ 76-80 CFZ 100 CFZ 110-120 CFZ 125-130 CFZ 140-150 CFZ 160

60 76-80 100 110-120 125-130 140-150 160

24x2,2 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5 24x1,5

10 x 80 10 x 80 10 x 80 10 x 80 10 x 80 10 x 80 10 x 80

85 85 85 85 85 85 85

M 8x200 M 8x200 M 8x200 M 8x200 M 8x200 M 8x200 M 8x200

150 158 170 175 182 190 200

M6x25 M6x25 M6x25 M6x25 M6x25 M6x25 M6x25

nominal diameter

ExD mm

d0 x Lt mm

h1 mm

M x Lp mm

Li mm

side screws

76-80 100

24x1,5 24x1,5

10 x 80 10 x 80

M 8x200 M 8x200

158 170

M6x25 M6x25

Black plastic-coated Code

Description

800N CFZ 76-80 794N CFZ 100

85 85

307

Perforated cement


cladding and pipe fixings

Vorpa CP

Light steel clamps for drain pipes

Concrete

Natural stone

Products group To fix • Drain pipes

Suitable for • Concrete • Natural stone • Solid brick Rounded clamp

Squared clamp

Examples of applications

Product information Characteristics • Double threaded M8 screws and nylon plug VN 10x60 • 3 different versions available

Technical data CP rounded clamp with wall plastic plug VN and double threaded screw

Code

494 491 492 493 495 496 498 499

Description

Lt mm

d0 mm

h1 mm

Lp mm

side screws

Ø mm

ExD mm

CP zincplated Ø 60 CP zincplated Ø 80 CP zincplated Ø 100 CP zincplated Ø 120 CP dark brown Ø 80 CP dark brown Ø 100 CP copper Ø 80 CP copper Ø 100

60 60 60 60 60 60 60 60

10 10 10 10 10 10 10 10

70 70 70 70 70 70 70 70

M 8x75 M 8x75 M 8x75 M 8x75 M 8x75 M 8x75 M 8x75 M 8x75

M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20 M6x20

60 80 100 120 80 100 80 100

28x1,5 28x1,5 28x1,5 28x1,5 28x1,5 28x1,5 28x1,5 28x1,5

CP squared clamp with wall nylon plug VN and double threaded screw

Code

501 502 505 506 508 509

Description

Lt mm

d0 mm

h1 mm

Lp mm

side screws

Ø mm

ExD mm

CP zincplated Ø 80x80 CP zincplated Ø 100x100 CP dark brown Ø 80x80 CP dark brown Ø 100x100 CP copper Ø 80x80 CP copper Ø 100x100

60 60 60 60 60 60

10 10 10 10 10 10

70 70 70 70 70 70

M 8x75 M 8x75 M 8x75 M 8x75 M 8x75 M 8x75

M6x20 M6x20 M6x20 M6x20 M6x20 M6x20

80x80 100x100 80x80 100x100 80x80 100x100

28x1,5 28x1,5 28x1,5 28x1,5 28x1,5 28x1,5

308

d0 = Hole diameter h1 = Min. hole depth Lt = Anchor length Lp = Pin length ExD = Width x thickness Ø = Pipe Øp = Pin diameter

Solid brick


cladding and pipe fixings

Vorpa VCR

Light copper clamps for pipes

Concrete

Natural stone

Solid brick

Technical data

VCR-VCR T light copper clamp with plastic wall plug VN and double threaded copper screw

VCR copper light clamp with pre-assembled side screw

VN R plastic wall plug VN with double threaded copper screw

Product information Characteristics • Light copper clamps Ø 10 to Ø 54 mm with plastic wall plug VN 6 x30 threaded copper screw • Pre-assembled side screws

Suggestion for use • Respect the installation data • Clean the hole before the installation

Technical data VCR T light copper clamp with plastic wall plug VN and double threaded copper screw Code

5400 5401 5402 5403 5404 5405 5406 5407 5409 5408 5410 5411

Description

VCR T 10 VCR T 12 VCR T 14 VCR T 16 VCR T 18 VCR T 22 VCR T 28 VCR T 32 VCR T 35 VCR T 38 VCR T 42 VCR T 54

Lt mm

d0 mm

h1 mm

Øv xLv mm

side screws

Ø mm

ExD lower portion (mm)

ExD upper portion (mm)

30 30 30 30 30 30 30 30 30 30 30 30

6 6 6 6 6 6 6 6 6 6 6 6

40 40 40 40 40 40 40 40 40 40 40 40

6x30 6x30 6x30 6x30 6x30 6x30 6x30 6x30 6x30 6x30 6x30 6x30

M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5

10 12 14 16 3/8” - 18 1/2” - 22 3/4” - 28 1” - 32 35 38 42 54

15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 16x1,2 16x1,2

10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 12x0,9 12x0,9

VCR copper light clamp with pre-assembled side screw Code

4400 4401 4402 4403 4404 4405 4406 4407 4409 4408 4410 4411

Description

VCR 10 VCR 12 VCR 14 VCR 16 VCR 18 VCR 22 VCR 28 VCR 32 VCR 35 VCR 38 VCR 42 VCR 54

side screws

Ø mm

ExD lower semicollar (mm)

ExD upper semicollar (mm)

M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5

10 12 14 16 3/8” - 18 1/2” - 22 3/4” - 28 1” - 32 35 38 42 54

15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 16x1,2 16x1,2

10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 12x0,9 12x0,9

d0 = Hole diameter h1 = Min. hole depth Lt = Plug length Lv = Screw length ExD = Width x thickness Ø = Pipe

VN R plastic wall plug VN with double threaded copper screw Description

Lt mm

d0 mm

h1 mm

Øv xLv mm

metric threaded

4768 VN R 6x30

30

6

40

6x30

M6

Code

309

d0 = Hole diameter h1 = Min. hole depth Lt = Plug length Lv = Screw length ExD = Width x thickness Øt = Pipes Øv = Screw diameter


cladding and pipe fixings

Vorpa CT

Steel clamp for light pipes

Concrete

Natural stone

Products group To fix • Light steel pipes

Suitable for • Concrete • Natural stone • Solid brick

Product information Characteristics • Stell clamps for light pipes Ø 10 to Ø 50mm with nylon wall plug VN V 8x40 and double threaded screw • Pre-assembled side screws

Suggestion for use • Respect the installation data • Clean the hole before the installation

Technical data

Code

1400 1401 1402 1403 1404 1405 1406 1407 1408 1409 1410 1415 1411 1412 1413 1414

Description

CT 10 CT 12 CT 14 CT 16 CT 18 CT 20 CT 22 CT 24 CT 26 CT 28 CT 32 CT 35 CT 38 CT 42 CT 48 CT 50

side screws

Øt mm

ExD lower semicollar (mm)

ExD upper semicollar (mm)

M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5 M5

10 12 14 16 18 20 22 24 26 28 32 35 38 42 48 50

15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 15x1,2 16x1,2 16x1,2 16x1,2

10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 10x0,9 12x0,9 12x0,9 12x0,9

Lt = Plug length Lv = Screw length ExD = Width x thickness Øt = Pipes Øv = Screw diameter

Accessories

VN V plastic wall plug VN with double threaded screw Description

Lt mm

d0 mm

h1 mm

Øv xLv mm

metric thread

768 VN V 8x40

40

8

50

6x40

M6

Code

310

Solid brick


cladding and pipe fixings

Vorpa KPO

Plastic clip for fixing metric insulation pipes Products group To fix • Metric insulation pipes cable

Suitable for • Nylon plug Ø6

Examples of applications

Product information Characteristics • Cables: Ø mini 16 - Ø maxi 50 • Raw Material: Polypropylen • Burning properties: according to IEC 60695-2-12 (GWFI): 650°C • Colour: Grey, RAL 7035 • Installation temperature: -5°C / +35°C • Working temperature: -30°C / +55°C

Benefit • Plastic clip for fixing or protecting rigid, metric insulating pipes in electrical installations, on vertical or horizontal surfaces (from Ø 16 to 50 mm) • Can be installed with a light-weight anchor • Rounded shape to facilitate pipe accomodiation • Elongated hole for adjusting wall fixings • Side hook for connecting other pipe clamps in series • Guide for laying in raceways • Allows a fast, economic and precise fixing of plastic pipes in the electrical applications

Installation sequence

Technical data

Code

2190 2191 2192 2193 2194 2195

Description

Ø pipe mm

Dc mm

X mm

C mm

width mm

KPO 16 KPO 20 KPO 25 KPO 32 KPO 40 KPO 50

16 20 25 32 40 50

15 19 24 30 38 48

10,5 12,5 15,0 20,0 25,0 32,5

17,5 19,5 22,0 26,5 30,4 35,4

16 16 16 16 16 16

axial load axial load retention daN insertion daN

8 9 9 6 7 5

6 7 6 9 7 7

311

KPO A (mm) B (mm) D (mm) F (mm G (mm) H (mm) I (mm) L (mm)

D16 15 26,9 22 16,1 4 9,1 10,4 27,1

D20 19 29,3 28,1 16,1 4 9,1 10,9 32,8

D25 24 35,55 34,2 16,1 4 9,1 11,1 39,1

D32 30 43,5 41,2 16,1 4 9,1 10,7 46,2

D40 38 49,7 48,1 16,1 4 9,1 10,4 53,1

D50 48 58,5 59,2 16,1 4 9,1 10,4 64,4


cladding and pipe fixings

Vorpa KP

Nylon clip for pipe and cable Products group Suitable for • nylon plug Ø6

Examples of applications

To fix • Metric insulation pipes cable

Product information Characteristics • Cables: Ø mini 8 - Ø maxi 60 • Raw Material: Polyamid 6 • Burning properties: according to IEC 60695-2-12 (GWFI): 650°C • Colour: Grey, RAL 7035 • Installation temperature: -5°C / +40°C • Working temperature: -30°C / +65°C

Benefit • Plastic clip with an upper part suitable for pipes saddle • Can be installed with a light-weight anchor • Made of polypropylene colour Grey RAL 7035 • Flammability rating: UL 94-HB • Simple interlocking of the upper part by pressure • The pressure of the inside flexible tabs fix the pipes in position, leaving room for longitudinal movements • A side hook for connecting other pipe saddles in series • Available in many diameters and packaging (box or industrial carton)

Installation sequence

Technical data

Code

1190 1191 1192 1193 1194 1195 1196 1197

Description

KP 8 KP 10 KP 16 KP 20 KP 25 KP 32 KP 40 KP 50

Ø mim mm

Ø max mm

resistance of the top part opening

4 8 12 16 20 25 32 40

8 12 16 23 25 32 40 60

10 10 23 20 25 31 40 50

KP A (mm) A1 (mm) B (mm) C (mm D (mm) E (mm) F (mm) G (mm) H (mm)

312

20 16 10 8 8,05 10,6 14,25 16,3 11,8 15,3 17,45 9,7 16,85 16,8 16,25 15,75 18,6 22,45 11,75 12 16,7 21,8 26,75 31 4 4,9 4,9 4,9 17,2 17,2 16,9 16,65 3,9 3,9 4 4 18,95 24,05 29,2 33,4

25 18,2 19,7 15,9 25,3 34,7 4,85 17 3,85 37,2

32 23,8 25,15 15,6 34,6 45,6 4,8 17 4 47,85

50 40 27,8 35,2 37 28,8 15,45 15,45 44,15 57,3 55,1 69,35 4,9 4,85 16,95 17,15 4,1 4,1 57,35 71,6


cladding and pipe fixings

Vorpa TC

Nylon clip with plug and screw

Concrete

Natural stone

Solid brick

Hollow brick

Perforated brick

Perforated cement

Products group

TC1

Suitable for • Concrete • Natural stone • Solid brick • Hollow brick • Perforated brick • Perforated cement

TC2

To fix • Metric insulation pipes • Cable

Product information Characteristics • Nylon clip with plug and screw • Double version available

Suggestion for use • The use of plastic anchors is not recommended for permanent suspended loading applications above 40°C

Benefit • Installation temperature: +5°C / +40°C • Working temperature: -40°C / +40°C (max +80°C fot short period)

Examples of applications

Installation sequence

Technical data

TC1 single nylon clip

Code

1090 1091 1092 2868 1093 1094 1095 1096 1097 1098 1100

Description

dv xLv mm

d0 mm

hmin mm

h1 mm

hef mm

Ø mm

TC1 10 TC1 12 TC1 14 TC1 15 TC1 16 TC1 18 TC1 20 TC1 22 TC1 24 TC1 26 TC1 28

3,5x35 3,5x35 4x45 4x45 4x45 4,5x50 4,5x50 4,5x50 6x60 6x60 6x60

5 5 6 6 6 8 8 8 10 10 10

30 30 50 50 50 60 60 60 80 80 80

30 30 35 35 35 45 45 45 50 50 50

20 20 25 25 25 30 30 30 40 40 40

10 12 14 15 16 18 20 22 24 26 28

313

d0 = Hole diameter h1 = Min. hole depth Lt = Plug length Lv = Screw length Ø = Pipes hef = Effective embedment depth dv = Screw diameter hmin = Minimum thickness of the fixture


cladding and pipe fixings

Vorpa TC

Nylon clip with plug and screw

Concrete

Natural stone

Solid brick

Hollow brick

Perforated brick

Perforated cement

Installation sequence

Technical data

TC2 double nylon clip

Code

2090 2091 2092 2867 2093 2094 2095 2096 2097 2100

Description

dv xLv mm

d0 mm

hmin mm

h1 mm

hef mm

Ø mm

TC2 10 TC2 12 TC2 14 TC2 15 TC2 16 TC2 18 TC2 20 TC2 22 TC2 24 TC2 28

4,5x50 4,5x50 4,5x50 4,5x50 4,5x50 6x60 6x60 6x60 6x60 6x60

8 8 8 8 8 10 10 10 10 10

60 60 60 60 60 80 80 80 80 80

60 60 60 60 60 70 70 70 70 70

30 30 30 30 30 40 40 40 40 40

10 12 14 15 16 18 20 22 24 28

d0 = Hole diameter h1 = Min. hole depth Lt = Plug length Lv = Screw length Ø = Pipes hef = Effective embedment depth dv = Screw diameter hmin = Minimum thickness of the fixture

Installation data Pull-out values in daN

Perforated brick Double brick UNI Concrete C20/25

1 daN ≃1 kg TC1 10÷12 30 42 54

TC1 14÷16 48 78 90

TC1 18÷22 72 84 96

TC1 24÷28 96 120 180

ATTENTION: an appropriate safety factor ≥ 6 should be applied on these values.

314

TC2 10÷16 72 84 96

TC2 18÷28 96 120 180


cladding and pipe fixings

Vorpa TC

Nylon clip with plug and screw

Concrete

Natural stone

Solid brick

Hollow brick

Perforated brick

Perforated cement

Products group Suitable for • Concrete • Natural stone • Solid brick • Hollow brick • Perforated brick • Perforated cement

To fix • Metric insulation pipes • Cable

EN 50146 conformity

Product information Characteristics • Nylon cable tie for plastic and metal pipe Benefit • Cables: Ø min 16 - Ø maxi 63 • Raw Material: Polyammide • Burning properties: according to IEC 60695-2-12 (GWFI): 650°C • Colour: Grey, RAL 7035 • Installation temperature: -5°C/+35°C • Working temperature: -40°C/+70°C • Flammability rating: UL 94-HB • Plastic cable for fixing or protecting rigid, metric insulating pipes in electrical installations, on vertical or horizontal surfaces (from Ø 16 to 63 mm) • Cam be installed with a light-weight anchor

Suggestion for use • The use of plastic anchors is not recommended for permanent suspended loading applications Examples of applications

Installation sequence

Technical data C A D B

Code

Description

2400 TC for Ø 16 - Ø 32 pipes 2401 TC for Ø 40 - Ø 63 pipes

d0 = hole diameter for screw

d0 mm

A mm

B mm

C mm

D mm

Working temperature

Installation temperature

Resistance of the cable tie opening

6 6

17.6 17.6

24.5 40.5

180 280

5.9 5.9

-40°C / +70°C -40°C / +70°C

-5°C / +35°C -5°C / +35°C

36 36

315


cladding and pipe fixings

Vorpa FZ CABLE TIE Products group suitable to fix • electrical installations • industrial wiring • automotive • panel buildings • special applications

natural cable tie

black cable tie

Product information Characteristics Material: Humidity absorption:

Polyamide 6.6 2,7% (50% relative humidity)

• Working temperature • Tightening temperature • Max admissable point • Melting temperature

-40°C ÷ 85°C -10°C ÷ 60°C +110°C for short time +256°C

Limit Oxygen Index (LOI): Flammability rating:

27% UL 94 class V2

Characteristics • High resistance to bases, oils, greases, oil derivatives • Limited resistance to acids • Not resistant to phenols and to chloride solvents • Halogen-free resins • UV resistance (black color) Benefits • Smooth rounded edges make them easier to be handled and safer to be installed • Bent rounded tip allows easier insertion through the head of the cables ties • Low friction coefficient of the material

Tested according to EN 50146 Installation sequence

Insert the tip of the tie.

Tighten manually the tie till complete fixing of the cables.

Avoid sharp bending of the tie: it will not improve the fixing strength.

Cut the exceeding part of the tie, with a few mm of safety length.

Technical data Code

Description natural cable tie

Code

Description black cable tie

00010 00011 00012 00013 00014 00015 00016

FZ N FZ N FZ N FZ N FZ N FZ N FZ N

00001 00002 00003 00004 00005 00006 00007

FZ B FZ B FZ B FZ B FZ B FZ B FZ B

100/2,5 160/2,5 200/2,5 140/3,5 280/3,5 360/3,5 280/4,5

Ø bundle mm

tensile strenght kg

21 40 52 35 80 103 79

8 8 8 13 13 13 22

100/2,5 160/2,5 200/2,5 140/3,5 280/3,5 360/3,5 280/4,5

316


cladding and pipe fixings

Vorpa CLIPS

Clips with single or double hole Products group

SFT 1 zincplated single hole clip hotdipped galvanized version available

SL 1 zincplated light single hole clip

SFT 2 zincplated double hole clip

SFT 2 with antirotation protuberance

SL 2 zincplated light double hole clip

Product information To fix • Rigid conduits / cable • Tubes for installations • Signs for road-signs Installation sequence

Technical data SFT 1 zincplated single hole clip (ideal for plumbing) Code

338 339 340 341 342 343 344 345 346 347

Description

A mm

B mm

C mm

E mm

F mm

Øt mm

SFT1 10 SFT1 12 SFT1 14 SFT1 3/8” SFT1 1/2” SFT1 3/4” SFT1 1” SFT1 1”1/4 SFT1 1”1/2 SFT1 2”

14 16 18 20 22 23 24 24 25 25

1,2 1,2 1,5 1,8 1,8 2,0 2,0 2,2 2,2 2,2

5 5 5 6 6 6 8,5 8,5 8,5 8,5

8 8 8 10 10 10 11 11 11 11

18 20 20 25 28 30 35 40 45 50

10 12 14 3/8” 1/2” 3/4” 1” 1”1/4 1”1/2 2”

SFZ hotdipped galvanizzed single hole clip (ideal for light and telephone poles) Code

Description

A mm

B mm

C mm

E mm

F mm

Øt mm

341ZC 342ZC 343ZC 344ZC 345ZC 346ZC 347ZC

SFZ 3/8” SFZ 1/2” SFZ 3/4” SFZ 1” SFZ 1”1/4 SFZ 1”1/2 SFZ 2”

20 22 23 24 24 25 25

1,8 1,8 2,0 2,0 2,2 2,2 2,2

6 6 6 8 8 8 8

10 10 10 11 11 11 11

25 28 30 35 40 45 50

3/8” 1/2” 3/4” 1” 1”1/4 1”1/2 2”

317

A = Width B = Thickness CxE = Anchor length F = Distance Øt = Pipes


cladding and pipe fixings

Vorpa CLIPS

Clips with single or double hole Technical data SL 1 zincplated light single hole clip (ideal for electrical rigid colduits) Code

3338 3339 3340 3341 3342 3343 3344 3345 3346 3347 3348

Description

A mm

B mm

C mm

E mm

F mm

Øt mm

SL1 7 SL1 10 SL1 12 SL1 16 SL1 20 SL1 22 SL1 26 SL1 28 SL1 32 SL1 38 SL1 50

10 14 14 14 14 14 14 14 15 15 15

0,9 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,8 1,8 1,8

4,5 6,5 6,5 6,5 6,5 6,5 6,5 6,5 6,5 6,5 6,5

6,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5

14 17 18 20 22 24 26 28 33 46 53

7-8 10-11 12-13 16-17 19-20 21-22 25-26 28-30 31-32 38-40 50

SFT 2 zincplated double hole clip (ideal for plumbing) Code

351 352 353 354 355 356 357 358

Description

A mm

B mm

C mm

E mm

F mm

Øt mm

SFT2 3/8” SFT2 1”1/2 SFT2 3/4” SFT2 1” SFT2 1”1/4 SFT2 1”1/2 SFT2 2” SFT2 2”1/2

15 22 23 23 24 24 25 30

1,5 2,0 2,0 2,2 2,2 2,2 2,2 2,2

6 8 8 8 8,5 8,5 8,5 Ø10

10 10 10 10 11 11 11 Ø10

50 56 60 70 80 90 100 130

3/8” 1/2” 3/4” 1” 1”1/4 1”1/2 2” 2”1/2

SL 2 zincplated light double hole clip (ideal for electrical rigid conduits) Code

3352 3353 3354 3355 3356 3357 3358 3359 3360 3361

Description

A mm

B mm

C mm

E mm

F mm

Øt mm

SL2 10 SL2 13 SL2 16 SL2 19 SL2 22 SL2 26 SL2 28 SL2 32 SL2 38 SL2 50

10 10 12 12 14 14 14 14 14 14

0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9

5 5 5 5 6,5 6,5 6,5 6,5 6,5 6,5

Ø5 Ø5 6,5 6,5 8,5 8,5 8,5 10 10 10

31 32 34 38 41 47 50 54 61 80

10 13 16 19 22 26 28 32 38 50

318

A = Width B = Thickness CxE = Anchor length F = Distance Øt = Pipes


cladding and pipe fixings

Vorpa CLIPS

Clips with single or double hole dati tecnici

SFT 2 with antirotation protuberance for traffic poles

Code

Description

357S SPS2 60

A mm

B mm

C mm

E mm

F mm

Øt mm

25

2,2

Ø 8,5

11

100

Ø 60

SFT 2 with antirotation protuberance for traffic poles

Description

360 SPS3 60

A mm

B mm

C mm

F mm

Øt mm

20

3,0

Ø9

102

Ø 60 90°

Øt

Code

10 125

F E

A

A B C F Øt

319

= Width = Thickness = Hole = Distance = Pipes

**


cladding and pipe fixings

Vorpa BANDING IN ROLL Banding for pipe applications Products group To fix • Flues • Traffic signs • Vertical PVC downpipes

Code 52361

Code 52362

Product information

Examples of applications

Characteristics • Zincplated and cloth banding for pipe applications Benefit • Ideal for vertical PVC downpipes, parallel conducts and suspended installations • Easy installation • Available in ondulated zincplated version and in resistant cloth Suggestion for use • Always check load bearing capacity • Respect the installation data

Lenght mm

Ø hole mm

A mm

B mm

C mm

52361 Zincplated banding 12 421 Zincplated banding 17 419 A2 S.S. 17 banding

10 10 10

5 7 7

12 17 17

0,7 0,7 0,8

9 20 20

52368 Cloth 15 banding

15

15

1

Code

Description

Ancillaries

Code

Description

52366 Steel nail 18 52367 Steel nail 22 52365 Striker

nail Ø mm

E mm

L mm

4,2 4,2

26 30

18 22

320


cladding and pipe fixings

Vorpa U-BOLT Heavy duty pipe clamp Products group Materials • S275JR EN 10025 (Fe 430) Accessories • No. 2 hexagonal nuts UNI 5588 class 8 • No. 2 plain washers UNI 6592 class 100HV white zinc-plated

Characteristics • Special U-shaped threaded screw. Suitable for clamping circular section elements of various sizes, from small diameter tubes to big pipes. • Made out of coated steel. • ISO metric thread. • Accessories for assembling included. • In line with 2002/95/CE (RoHS) regulations.

Technical data

Code

5200 5201 5202 5203 5204 5205 5206 5207 5208 5209 5210 5211 5212 5213

Description

h mm

b mm

e mm

a mm

d1 mm

d2 mm

d3 mm

U-BOLT 18 U-BOLT 22 U-BOLT 28 U-BOLT 35 U-BOLT 40 U-BOLT 48 U-BOLT 60 U-BOLT 75 U-BOLT 90 U-BOLT 100 U-BOLT 115 U-BOLT 140 U-BOLT 168 U-BOLT 220

37 43 47 55 63 73 85 101 113 130 142 169 202 254

19 25 25 25 25 30 30 30 30 35 35 35 45 45

24 28 33 40 49 57 69 85 97 110 123 148 178 230

18 22 27 34 43 49 61 77 89 102 115 140 168 220

3/8” 1/2” 3/4” 1” 1”1/4” 1”1/2” 2” 2”1/2” 3” 3”1/2” 4” 5” 6” 8”

5,3 5,3 5,3 5,3 5,3 7,1 7,1 7,1 7,1 7,1 7,1 7,1 8,9 8,9

M6 M6 M6 M6 M6 M8 M8 M8 M8 M8 M8 M8 M10 M10

321

h b a e d1 d2 d3

= pipe clamp height = metric thread = pipe clamp width = distance = for pipe = diameter = thread


cladding and pipe fixings

Vorpa VNS

Fixings for boilers, water heaters and flush tanks

Concrete

Natural stone

Products group Suitable for • Concrete • Natural stone • Solid brick

To fix • Boilers • Flush tanks Examples of applications

Installation sequence

Product information Characteristics • Steel hook with nylon plug to fix boilers and flush tanks

Suggestion for use • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation

Technical data

Description

Lt mm

d0 mm

h1 mm

Lp mm

Øp mm

397 VNS 8/65 398 VNS 10/75 417 VNS 10/95

60 60 60

10 12 12

75 75 75

70 75 95

8 10 10

Code

Installation data Recommended values in daN Materials Concrete C20/25 Double brick Uni with plaster

1 daN ≃1 kg VNS 8 Ø10 60 45

VNS 10 Ø12 105 75

322

d0 h 1 L t Lp Øp

= Hole diameter = Min. hole depth = Plug length = Hook length = Hook diameter

Solid brick


cladding and pipe fixings

Vorpa TV

Fixing set for wall toilets and built-in toilets

Concrete

Natural stone

Solid brick

Perforated brick

Products group TV N fixing set for wall toilets

TV NL fixing set for built-in toilets

Suitable for • Concrete • Natural stone • Solid brick • Perforated brick • Perforated cement Examples of applications

TV M fixing set for wall toilets

TV ML fixing set for built-in toilets

Characteristics • TV N: nylon bushing and steel nut with wall plug VN • TV NL: 2 flanged threaded nylon nuts with wall plug VN • TV M: nylon bushing and steel nut with wall plug VH • TV ML: 2 flanged threaded nylon nuts with wall plug VH Suggestion for use • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation

Installation sequence TV N - TV M

Clean the hole before the installation TV NL - TV ML

Clean the hole before the installation 323

To fix • Wash basins • Built-in toilets • Urinal

Perforated cement


cladding and pipe fixings

Vorpa TV

Fixing set for wall toilets and built-in toilets

Concrete

Natural stone

Solid brick

Perforated brick

Technical data

TV N fixing set for wall toilets

Code

Description

Lt mm

d0 mm

h1 mm

Lp mm

Øp mm

Tfix mm

205 206 207 *1206

TVN 8/90 TVN 10/120 TVN 10/140 TVN 10/120 INOX A2

60 60 60 60

10 12 12 12

75 75 75 75

90 120 140 120

M8 M10 M10 M10

25 45 65 45

* A2 stainless steel Recommended load in daN

d0 h1 Lt Lp Øp Tfix

= Hole diameter = Min. hole depth = Plug length = Hook length = Hook diameter = Fixture thickness

d0 h1 Lt Lp Øp Tfix

= Hole diameter = Min. hole depth = Plug length = Hook length = Hook diameter = Fixture thickness

1 daN ≃1 kg TVN 8/90 Ø10 60 50

Materials Concrete C20/25 Double brick UNI with plaster

TVN 10/120 Ø12 105 80

TVN 10/140 Ø12 100 70

TV NL fixing set for built-in toilets

Code

Description

1208 TV NL 10/180

Lt mm

d0 mm

h1 mm

Lp mm

Øp mm

Tfix mm

60

12

75

180

M10

105

Recommended load in daN Materials Concrete C20/25 Double brick UNI with plaster

1 daN ≃1 kg TV NL 10/180 Ø12 90 60

324

Perforated cement


cladding and pipe fixings

Vorpa TV

Fixing set for wall toilets and built-in toilets

Concrete

Natural stone

Solid brick

Perforated brick

Technical data

TV M fixing set for wall toilets

Code

Description

231 TV M 10/145 *2231 TV M 10/145 INOX A2

Lt mm

d0 mm

h1 mm

Lp mm

Øp mm

Tfix mm

70 70

14 14

85 85

145 145

M10 M10

45 45

* A2 stainless steel Recommended load in daN

1 daN ≃1 kg

d0 h1 Lt Lp Øp Tfix

= Hole diameter = Min. hole depth = Plug length = Hook length = Hook diameter = Fixture thickness

d0 h1 Lt Lp Øp Tfix

= Hole diameter = Min. hole depth = Plug length = Hook length = Hook diameter = Fixture thickness

TV M 10/145 Ø14 120 90

Materials Concrete C20/25 Double brick UNI with plaster

TV ML fixing set for built-in toilets

Code

Description

232 TV M L10/145 *2232 TV M L10/145 INOX A2

Lt mm

d0 mm

h1 mm

Lp mm

Tfix mm

70 70

14 14

85 85

180 180

85 85

* A2 stainless steel Recommended load in daN Materials Concrete C20/25 Double brick UNI with plaster

1 daN ≃1 kg TV ML 10/80 Ø14 80 40

325

Perforated cement


cladding and pipe fixings

Vorpa TV NC

Fixing set for wall flush tanks

Concrete

Natural stone

Products group Suitable for • Concrete • Natural stone • Solid brick

To fix • Wall flush tanks

Examples of applications

Installation sequence

Product information Characteristics • Heavy steel hook with plastic plug, to fix wall flush tanks, the white sleeve prevents contact between the screw and the ceramics

Suggestion for use • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation

Technical data

Code

Description

2440 TV NC 8/90

Lt mm

d0 mm

h1 mm

Lp mm

Øp mm

Tfix mm

60

10

75

90

8

35

Installation data Recommended values in daN Materials Concrete C20/25 Double brick UNI with plaster

1 daN ≃1 kg TV NC Ø10 60 50

326

d0 h1 Lt Lp Øp Tfix

= Hole diameter = Min. hole depth = Plug length = Hook length = Hook diameter = Fixture thickness

Solid brick


cladding and pipe fixings

Vorpa TV NO - NK

Fixing set for free-standing toilets and bidets Technical data Sanitary fixing set for toilets and bidets with vertical holes

TV NO brass Code

Description

247 TV NO 10/80 2247 TV NO 10/80 INOX A2

TV NO stainless steel A2 Lt mm

d0 mm

h1 mm

Lp mm

Øp mm

Set content

50 50

10 10

75 75

80 80

6 6

4 plugs 10x50 4 screws 6x80 4 white sleeves 4 nuts

Installation sequence TV NO

Respect the installation data, clean the hole before the installation.

Description

2248 TV NK 10/50

= Hole diameter = Min. hole depth = Plug length = Hook length = Hook diameter = Screw diameter = Screw length

The pronounced rim prevents contact between the screw and ceramics.

Sanitary fixing set for toilets and bidets with side holes

Code

d0 h 1 L t Lp Øp Ø v Lv

Lt mm

d0 mm

h1 mm

Lv mm

Øv mm

Set content

50

10

75

60

7

2 plugs 10x50 - 2 hexagonal screws 7x65 2 nylon angles L - 2 washer Ø8 2 cover caps Ø18 2 nylon sleeves Ø15 2 screws Ø4,5x45

Installation sequence TV NK

Respect the installation data, clean the hole before the installation.

327


cladding and pipe fixings

Vorpa TVH

Fixing set for water heathers

Concrete

Natural stone

Solid brick

Perforated brick

Products group Suitable for • Concrete • Natural stone • Solid brick • Perforated brick • Perforated cement

To fix • Boilers • Water heather Examples of applications

Installation sequence

Product information Characteristics • Heavy steel hook with plastic plug to fix boilers and water heaters

Suggestion for use • Check load bearing capacity values • Respect the installation data • Clean the hole before the installation

Technical data

Description

Lt mm

d0 mm

h1 mm

Lp mm

Øp mm

I mm

244 TVH 14

75

14

85

98

8,8

18

Code

Installation data Recommended values in daN Materials Concrete C20/25 Double brick Uni with plaster

1 daN ≃1 kg TVH 14 120 90

328

d0 h 1 Lt Lp Øp l

= Hole diameter = Min. hole depth = Plug length = Hook length = Hook diameter = Distance

Perforated cement


Masonry and HSS drills


masonry and HSS drills

Vorpa GOLDCRAFT universal drill bit

Concrete

Solid brick

Natural stone

Metal

Wood

Glass block

PVC

product group Suitable • concrete • solid brick • natural stone • metal • wood • glass block • PVC • backed clay • porcellain

Drive

Execution

product information Characteristics • Universal drill bit with special cutting edge geometry. Thanks to diamond-ground carbide tips GOLDCRAFT drill bit is suitable for almost all materials. Benefits • Special cutting edge geometry (see diagram) • The asymmetric spiral shape enable an optimum removal of drilling dust • High-temperature brazing at about 1.120 °C • Special cutting helix with micro surface hardness • Extremely wear resistant Suggestion for use • Regrinding of the carbide tip becomes necessary during prolonged use • Higher wear of carbide tip when drilling in abrasive materials • Only use sharp drill bits for drilling in porcelain, ceramics, glass block technical data Guide values for universal drill bits Goldcraft D

4

/mm

Ø mm

16

2350

1500

soft wood

1880

1030

ceramics

1580

800

1120

640

steel, cast steel

1700

510

hard wood

850

410

glass, crystal

masonry, marble, artificial stone,concrete granite, tiles, plastic materials, acrylic

330

Backed clay

Porcellain


masonry and HSS drills

Vorpa GOLDCRAFT universal drill bit

Concrete

Solid brick

Natural stone

technical data Vorpa GOLDCRAFT® Code

Description

5001 GOLDCRAFT 3 5002 GOLDCRAFT 4 5003 GOLDCRAFT 5 5004 GOLDCRAFT 5,5 5005 GOLDCRAFT 6 5006 GOLDCRAFT 6,5 5007 GOLDCRAFT 7 5008 GOLDCRAFT 8 5009 GOLDCRAFT 9 5010 GOLDCRAFT 10 5011 GOLDCRAFT 12 P1 long series mm 150 - 200

Code

5021 5022 5023 5024 5025 5026

X 70 X 75 X 85 X 85 X 100 X 100 X 100 X 120 X 120 X 120 X 150

Description

GOLDCRAFT P1 5 X 150 GOLDCRAFT P1 6 X 150 GOLDCRAFT P1 6,5 X 150 GOLDCRAFT P1 8 X 200 GOLDCRAFT P1 10 X 200 GOLDCRAFT P1 12 X 200

Usable length mm

Shank diameter mm

40 40 50 50 60 60 60 80 80 80 90

2,8 3,8 4,5 4,5 5,5 5,5 6,5 7,5 8 9 10

Usable length mm

Shank diameter mm

110 110 110 135 135 135

4,5 5,5 5,5 7,5 9 10

Vorpa GOLDCRAFT® Code

5030

Description

Goldcraft set

Set contents

5 GOLDCRAFT drills short version Ø mm 4 - 5 - 6 - 8 - 10

331

Metal

Wood

Glass block

PVC

Backed clay

Porcellain


masonry and HSS drills

Vorpa HARDTECH drill bit for hardtest materials

Concrete

Natural stone

Glass block

Backed clay

Porcellain

Product group Materials: • Expert for granite, gneissic rock, slate, basalt • Specially suitable for hard ceramic tiles, porcelain and other hard materials

Prüfgemeinschaft Mauerbohrer (PGM) Certified product

Drive

Execution 120°

Product information Characteristics • Hard stone drill bit with special cutting edge geometry Application • ISO 5468 • Asymmetric spiral shape • Staight flute entry • Milled flute • Spacial carbide tip • Diamond-ground carbide tip • High-temperature vacuum brazing at 1120°C • Ground surface

Advantages • Wear resistant carbide drill bit with long life time • High drilling speed • The drill bit can be resharpened with a diamond or silicon carbide grinding wheel • Very long service life Special carbide tip • High portion of tungsten carbide • Homogenious fine structured grain • Special cutting edge of 120°C • Preceise diamond grinding

Technical data

Code

8062 8063 8064 8065 8066

Code

8067

Description

HARDTEC 4 X 75 HARDTEC 5 X 85 HARDTEC 6 X 100 HARDTEC 8 X 120 HARDTEC 10 X 120

Description

HARDTEC set

Usable length mm

Shank diameter mm

40 50 60 75 75

4 5 6 8 10

Set contents

5 HARDTEC drills Ø mm. 4 - 5 - 6 - 8 -10

332


masonry and HSS drills

Vorpa PMS

metal universal drill bit for masonry

Concrete

Solid brick

Natural stone

product group Suitable • concrete • solid brick • natural stone

Drive

Execution

product information Characteristics • metal universal drill bit for masonry

Benefits • good chip and dust removal • for hobbyist and professional use

technical data

Code

6001 6002 6003 6004 6005 6006 6007 6008 6009 6010 6011 6012 6013 6014 6015 6016 6017 6018 6019 6020

Description

Shank diameter mm

PM S 3 X 60 PM S 4 X 75 PM S 4,5 X 85 PM S 5 X 85 PM S 5,5 X 85 PM S 6 X 100 PM S 6,5 X 100 PM S 7 X 100 PM S 8 X 120 PM S 8,5 X 120 PM S 9 X 120 PM S 10 X 120 PM S 11 X 150 PM S 12 X 150 PM S 13 X 150 PM S 14 X 150 PM S 15 X 150 PM S 16 X 150 PM S 18 X 160 PM S 20 X 160

2,5 3,5 3,5 4 4 5 5 5,5 6 6 7 8 8 8 8 10 10 13 13 13

Code

6060

Code

Description

P1 long series mm 150 - 200 6032 PM SP1 6 X 200 6033 PM SP1 8 X 200 6034 PM SP1 1 0 X 200 6035 PM SP1 1 2 X 200 6036 PM SP1 14 X 200 P2 long series mm 400 6040 PM SP2 8 X 400 6041 PM SP2 1 0 X 400 6042 PM SP2 1 2 X 400 6043 PM SP2 1 4 X 400 6044 PM SP2 1 6 X 400 6045 PM SP2 1 8 X 400 6046 PM SP2 2 0 X 400 P3 long series mm 600 6050 PM SP3 8 X 600 6051 PM SP3 10 X 600 6052 PM SP3 1 2 X 600 6053 PM SP3 1 4 X 600 6054 PM SP3 1 6 X 600 6055 PM SP3 1 8 X 600 6056 PM SP3 20 X 600

Description

Content

5 PM S drills short version

SET PM S

PMS set

Ø mm. 4 - 5 - 6 - 8 -10

333

Shank diameter mm

5 6 8 8 10 6 8 8 10 13 13 13 6 8 8 10 13 13 13


masonry and HSS drills

Vorpa SDS TURBO PRO

4 cutting edges drill bit suitable for concrete, professional use

Concrete

Solid brick

Natural stone

product group Suitable • concrete • solid brick • natural stone

Drive

Execution

product information Characteristics • X-Shape 4 cutting edges drill bit for perforated hammers, professional use • Made of chrome-nickel-molybdenum steel, shot-peened and hardened • Specially designed head geometry for better center drilling • Conical spiral drill bit Benefits • High drilling speed thanks to the helix carrying forward the impact of the machine up to the drilling head • Low hand-arm vibrations thanks to the helix concept reducing the vibration loads generated during drilling • High stiffness and longer service life • 2 larger-volume flutes granting ideal and fast drilling-dust removal • Greater fracture resistance thanks to the rounded step transitions and the strengthened core • The geometry with 4 cutting edges protects the bit against damage when impacting on reinforced steel • Head geometry characterized by 6 drill-levels. Different setting depths of major and side plates. Shearing force is shared on 2 levels and secure a long life • Cylindrical drilling holes, also in reinforced concrete. Drilling process will not be distracted

1) Higher drilling speed - The symmetric X-shape achieves higher drilling speed, in comparison to standard 90° design - X-shape with big entry-flutes for optimized drill-dust removal 2) Higher strength - Precise spot-drilling due to the centering point. Armor-resistant and easy drilling into reinforced concrete - The multi-angle drill bit tip achieves an ideal drilling result, with long service life at the same time

3) More clean - 4 cutting edges concept provide an accurate and correct guidance of the drill bit. Optimum vibration behavior 4 times secured quality due to: - Optimized hardening and brazing process at 1.120° - Second “stress-free” hardening - Shot-blased surface - Straightening process for exact true-running accuracy

334


masonry and HSS drills

Vorpa SDS TURBO PRO

4 cutting edges drill bit suitable for concrete, professional use

Concrete

technical data

Code

7130 7131 7132 7133 7134 7135 7136 7137 7138 7139 7140 7141 7142 7143 7144 7145 7146 7147 7148 7149 7150 7151 7152 7153 7154

Code

7160

Description

SDS TURBO 5 x 110 SDS TURBO 5 x 160 SDS TURBO 5 x 210 SDS TURBO 6 x 110 SDS TURBO 6 x 160 SDS TURBO 6 x 210 SDS TURBO 6 x 260 SDS TURBO 8 x 110 SDS TURBO 8 x 160 SDS TURBO 8 x 210 SDS TURBO 8 x 260 SDS TURBO 10 x 160 SDS TURBO 10 x 210 SDS TURBO 10 x 260 SDS TURBO 10 x 310 SDS TURBO 10 x 460 SDS TURBO 12 x 160 SDS TURBO 12 x 210 SDS TURBO 12 x 260 SDS TURBO 12 x 310 SDS TURBO 12 x 450 SDS TURBO 14 x 160 SDS TURBO 14 x 210 SDS TURBO 14 x 260 SDS TURBO 14 x 450

Description

Set SDS TURBO

Box (pcs)

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Box (pcs)

1

Usable length mm

50 100 150 50 100 150 200 50 100 150 200 100 150 200 250 400 100 150 200 250 400 100 150 200 400

Set contents

7 drills SDS TURBO Ø mm. 5x110 - 6x110 - 6x160 8x110 - 8x160 - 10x160 - 12x160

335

Solid brick

Natural stone


masonry and HSS drills

Vorpa SDS PLUS

hammer drill bit, professional use

Concrete

product group Suitable • concrete • solid brick • natural stone

Drive

Execution

product information Characteristics • Made of chrome-nickel-molybdenum steel, shot-peened and intermediate level hardened • Specially designed carbide plate with centring tip • Multi-step helix Benefits • Reduces vibration loads generated during drilling • Reduces torsion loads generated during drilling • No drilling dust • Higher drilling speed • Transports the impact energy of the hammer drilling machine in an optimal way • Greater fracture resistance • Larger cutting angle • 64% faster thanks to Multi-step helix The helix is protected by patents. The number of spiral steps and radiuses on the drill depends on the hole diameter

4 – 5 mm 6 – 7 mm 8 – 9 mm 10 – 12 mm 13 – 14 mm 15 – 16 mm 17 – 26 mm

2 spiral steps 4 spiral steps 6 spiral steps 8 spiral steps 6 spiral steps 8 spiral steps 10 spiral steps

6 radiuses 10 radiuses 14 radiuses 18 radiuses 14 radiuses 18 radiuses 22 radiuses

Suggestion for use • For a working length of 400 mm and more, pre-drilling must be carried out to a depth of at least 150 mm with a drill bit of the same diameter. • For a working length of 950 mm and more, pre-drilling must be carried out to a depth of at least 400 mm with a short drill bit of the same diameter. • The warranty does not apply to extra-long drill bits of 1.000 mm and more.

336

Solid brick

Natural stone


masonry and HSS drills

Vorpa SDS PLUS

hammer drill bit, professional use

Concrete

technical data

Code

2000 1997 1998 2001 2002 2003 2004 2033 2005 2006 2007 2008 2009 2046 2034 2041 2035 2010 2011 2012 2042 2043 2013 2036 2014 2044 2015 2016 2031 2018 2019 2020 2021 2032 2022 2023 2048 2024 2039 2025 2040 2026 2037 2027 2038 2028 2049 2029 2030

Description

SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS SDS

-PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS -PLUS

4 X 4 X 4 X 5 X 5 X 6 X 6 X 6 X 7 X 7 X 8 X 8 X 8 X 8 X 8 X 8 X 9 X 9 X 10 X 10 X 10 X 10 X 10 X 10 X 12 X 12 X 12 X 12 X 12 X 14 X 14 X 14 X 14 X 14 X 15 X 16 X 16 X 16 X 16 X 18 X 18 X 20 X 20 X 20 X 20 X 22 X 24 X 25 X 26 X

110 160 180 110 160 110 160 210 110 160 110 160 210 310 400 460 160 210 110 160 210 260 310 460 165 210 265 450 600 165 215 315 450 600 165 215 310 450 600 200 300 200 300 450 600 450 250 450 450

Box (pcs)

Usable length mm

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

50 100 120 50 100 50 100 150 50 100 50 100 150 250 350 410 100 150 50 100 150 200 250 400 100 150 200 400 550 100 150 250 400 550 100 150 250 400 550 150 250 150 250 400 550 400 210 400 400

337

Solid brick

Natural stone


masonry and HSS drills

Vorpa SDS PLUS V4

hammer drill bit 4 cutter, professional use

Concrete

Solid brick

product group Suitable • concrete • solid brick • natural stone

Drive

Execution

product information Characteristics • Hammer drill bit 4 cutter, professional use

Benefits • Considerably faster drilling progress • Significantly longer life • High drilling speed • Fast transport of drilling dust • High grade of stiffness and long service life • High resistance against breakage

Benefits • Carbide plate with centring tip • Straight flute entry • High-temperature brazing at about 1100°C • Particulary suitable for fastenings • Simple precise drilling of pilot holes

technical data

Code

2149 2051 2052 2053 2054 2055 2150 2151 2056 2057 2058 2059 2171 2155 2060 2061 2062 2063 2172 2064 2065 2066 2067 2159 2068

Description

SDS-plus 4 X 110 SDS-plus 5 X 110 SDS-plus 5 X 160 SDS-plus 6 X 110 SDS-plus 6 X 160 SDS-plus 6 X 210 SDS-plus 7 X 110 SDS-plus 7 X 160 SDS-plus 8 X 110 SDS-plus 8 X 160 SDS-plus 8 X 210 SDS-plus 8 X 260 SDS-plus 8 X 450 SDS-plus 9 X 160 SDS-plus 10 X 110 SDS-plus 10 X 160 SDS-plus 10 X 210 SDS-plus 10 X 260 SDS-plus 10 X 450 SDS-plus 12 X 160 SDS-plus 12 X 210 SDS-plus 12 X 260 SDS-plus 12 X 450 SDS-plus 12 X 600 SDS-plus 14 X 160

Usable length mm

Code

2069 2070 2071 2162 2072 2073 2074 2075 2165 2076 2077 2166 2167 2078 2079 2080 2081 2169 2082 2168 2083 2170 2084

50 50 100 50 100 150 50 100 50 100 150 200 400 100 50 100 150 200 400 100 150 200 400 550 100

338

Description

SDS-plus 14 X 210 SDS-plus 14 X 260 SDS-plus 14 X 450 SDS-plus 14 X 600 SDS-plus 16 X 160 SDS-plus 16 X 210 SDS-plus 16 X 260 SDS-plus 16 X 450 SDS-plus 16 X 600 SDS-plus 18 X 210 SDS-plus 18 X 260 SDS-plus 18 X 450 SDS-plus 20 X 210 SDS-plus 20 X 260 SDS-plus 20 X 450 SDS-plus 20 X 600 SDS-plus 22 X 450 SDS-plus 24 X 260 SDS-plus 24 X 450 SDS-plus 25 X 260 SDS-plus 25 X 450 SDS-plus 25 X 600 SDS-plus 26 X 600

Usable length mm

150 200 400 550 100 150 200 400 550 150 200 400 150 200 400 550 400 200 400 200 400 550 550

Natural stone


masonry and HSS drills

Vorpa HSS DIN 338

Twist drill bit for use on materials, with a tensile strength up to 800 N/m2

Metal

Cast iron

Brass

product group Suitable • metal • cast iron • brass

Drive

Execution

product information Characteristics • High performance high-speed steel drill bit suitable for metal Benefits • High elasticity due to heat forming • Robust core thickness and distinct hardness • Special surface treatment reducing dust deposition • Reduced danger of breakage thanks to the torsional strength • Particularly suitable for professional use in metal, alloyed and unalloyed steel with a tensile strength up to 800 N/mm2, non-iron metal, cast iron and hard plastic

Suggestions for use • In case of horizontal drilling and drilling depths 5 times bigger than diameter it is necessary to reduce the drilling speed of 20-40% • Use special drilling oils in case of extremely hard alloy and heat resistant materials • Use normal freezing mixtures for standard steel or low adhesiveness materials • Dry-drilling in case of short chips, brass and cast iron • Lift the drill bit for time to time in order that the oil can pene trate into the material • Sharpen the cutting edges regularly • Do not use drill bits with rotopercussion

technical data

HSS DIN 338

Code

7001 7040 7002 7041 7003 7042 7004 7043 7005 7044 7006 7045 7007 7046 7008 7047

Description

HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS

1 X 34 1,25 X 38 1,50 X 40 1,75 X 46 2 X 49 2,25 X 53 2,50 X 57 2,75 X 61 3 X 61 3,25 X 65 3,50 X 70 3,75 X 70 4 X 75 4,25 X 75 4,50 X 80 4,75 X 80

Usable length mm

12 16 18 23 24 27 30 33 33 36 39 39 43 43 47 47

339


masonry and HSS drills

Vorpa HSS DIN 338

Twist drill bit for use on materials, with a tensile strength up to 800 N/m2

Metal

technical data

HSS DIN 338

Code

Description

7009 7048 7010 7049 7011 7050 7012 7051 7013 7014 7015 7016 7017 7018 7019 7020 7021 7022 7023 7024 7025

HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS HSS

Usable length mm

5 X 86 5,25 X 86 5,50 X 93 5,75 X 93 6 X 93 6,25 X 101 6,50 X 101 6,75 X 109 7 X 109 7,50 X 109 8 X 117 8,50 X 117 9 X 125 9,50 X 125 10 X 133 10,50 X 133 11 X 142 11,50 X 142 12 X 151 12,50 X 151 13 X 151

52 52 57 57 57 63 63 69 69 69 75 75 81 81 87 87 94 94 101 101 101

Guidelines for the execution of pre-drills to thread according to trhead type M

D

3 4 5 6 8 10 12

2,4 - 2,5 3,2 - 3,3 4,0 - 4,2 4,8 - 5,0 6,4 - 6,8 7,9 - 8,5 9,6 - 10,2

art 7030

Code

7030 7031 7034 7032

art 7031

art 7034

Description

Diameter every 0,5 mm

19 drill bit 25 drill bit 13 drill bit 19 drill bit

from 1 to 10 from 1 to 13

art 7032

Diameter every 0,5 + Ø 3,2 and 4,8 mm

Diameter every 1 mm

Box type

Metal Metal Plastic Metal

from 1,5 to 6,5 from 1 to 10

340

Cast iron

Brass


masonry and HSS drills

Vorpa HSS CO 5% DIN 338

5% cobalt twist drill bit for use on materials with a tensile strenght above 800N/m2, professional use

A2 stainless steel Special A4 stainless steel alloys

Alloyed stell

product group Suitable • A2 stainless steel • A4 stainless steel • special alloys • alloyed steel

Drive

Execution

product information Code

7100 7101 7102 7103 7104 7105 7106 7107 7108 7109 7110 7111 7112 7113 7114 7115 7116 7117 7118 7119 7120 7121 7122 7123 7124 7125 7126

Description

HSS Co 5% 1x34 HSS Co 5% 1,5x40 HSS Co 5% 2x40 HSS Co 5% 2,5x57 HSS Co 5% 3x61 HSS Co 5% 3,2x65 HSS Co 5% 3,5x70 HSS Co 5% 4x75 HSS Co 5% 4,2x75 HSS Co 5% 4,5x80 HSS Co 5% 5x86 HSS Co 5% 5,5x93 HSS Co 5% 6x93 HSS Co 5% 6,5x101 HSS Co 5% 7x109 HSS Co 5% 7,5x109 HSS Co 5% 8x117 HSS Co 5% 8,5x117 HSS Co 5% 9x125 HSS Co 5% 9,5x125 HSS Co 5% 10x133 HSS Co 5% 0,5x133 HSS Co 5% 11x142 HSS Co 5% 11,5x142 HSS Co 5% 12x151 HSS Co 5% 12,5x151 HSS Co 5% 13x151

Usable length mm

12 18 24 30 33 36 39 43 43 47 52 57 57 63 69 69 75 75 81 81 87 87 94 94 101 101 101

19 drill bits set

Code

7037 7038

Shank diameter mm

Characteristics • Cross-ground finish to DIN 1412 C (5% cobalt from Ø 3,0 mm). 135° conical section.

1,0 1,5 2,0 2,5 3,0 3,2 3,5 4 4,2 4,5 5 5,5 6 6,5 7 7,5 8 8,5 9 9,5 10 10,5 11 11,5 12 12,5 13

Benefits • Direct drilling without prior centering or drilling of a pilot hole • Safe pilot hole drilling, even in slanting surfaces, in pipes and/ or welds • The feeding power is reduced by up to 50% • Even chip removal and reduction of chip friction • Extremely true running and precise round holes • The drill bit facilitates an increase in drilling progress by up to 45% • No jamming of the main cutting edge and no slipping of the drill bit for through-holes • High fracture strength and long life • Reduced friction due to external diameter tapering in the shank direction • Fast drilling progress through chemical thermal method of hardening and accurate cross-ground finish • Due to the alloying addition of 5% Co these drill bits are well- suited for workpieces with a tensile strength of more than 800N/mm2. • Extra high temperature strength to cope with suboptimal supply of coolant • Up to 20% higher durability than identically constructed HSS drill bits used under the same operating conditions Suggestions for use • Use special drilling oils in case of extremely hard alloy and heat resistant materials • Use normal freezing mixtures for standard steel or low adhesiveness materials • Dry-drilling in case of short chips, brass and cast iron • Lift the drill bit for time to time in order that the oil can penetrate into the material • Sharpen the cutting edges regularly • Do not use drill bits with rotopercussion

25 drill bits set

Description

Diameter every 0,5 mm

19 drill bits 25 drill bits

from 1 to 10 from 1 to 13

Box type

Metal Metal

341



PERSONALIZED YOUR SHOP

DIY products require a good looking environment that can make a positive impression on the customers. It is very important to lay down an interior by using the right displays and the best layout. Vorpa is here to offer the solution suitable for different needs. Moreover you can rely on a well-known brand, professional and high quality products and wide range satisfying eny DIY fixing requirement.


about us

Who we are Vorpa is a company specialized in the design and production of fixing systems that achieved a significant position in the Italian and European market, thanks to precise orientations focused on two priority objectives: to provide an excellent level of manufacturing quality and strengthen all initiatives that provide value-added with the service to building and hardware distributors.

How to reach us

TRIESTE PADOVA

MILANO

VENEZIA

RICCIONE

TORINO GENOVA

BOLOGNA RICCIONE FIRENZE REP. SAN MARINO

Contact ol

B

Instagram Twitter

na

Facebook

og

www.vorpa.com

A

ut

RIMINI SUD Casello - Exit

Rimini

os

tr

ad

RICCIONE Casello - Exit

a

RICCIONE

A

CATTOLICA Casello - Exit

14

Cattolica

M

ot

or

w

A

ay

ANCONA

a

on

nc


www.vorpa.com

Srl

Contact Via San Leo, 5 - 47838 - Riccione - Italy Tel. +39 0541 607111 Fax +39 0541 699015 vorpa@vorpa.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.