Smart Port

Page 1

POWER-INJECTABLE PORTS


Better Outcomes. Fewer Complications. POWER-INJECTABLE PORTS

The tangential outlet and clear-flow technology behind Smart Port® power-injectable ports set up efficient flushing action to hyper cleanse the entire reservoir. Each model features a light-weight design and a CT-engraved port body for better identification. These ports are clinically indicated for power-injections up to 5mL/sec and 300 psi and are MRI-conditional—3 Tesla.

Smart Port ® CT > Blue boot strain-relief mechanism offers a secure feel and snug fit > Silicone-filled suture holes available for ease of explants > Fluoromax® 100% silicone radiopaque catheter with an atraumatic radiopaque tip > Footprint (in): X: 1.045, Y: 1.053*; Height (in): 0.520; Septum Diameter (in): 0.470

Smart Port ® CT Low-Profile > Low-Profile 6.6F catheter reduces the risk of thrombosis > Large septum diameter offers greater target area > One-step locking mechanism means fast, simple and secure procedures > Silicone-filled suture holes prevent tissue ingrowth > Carbothane® catheter offers balance between softness and strength coupled with greater drug compatibility > Footprint (in): X: 0.890, Y: 0.879*; Height (in): 0.450; Septum Diameter (in): 0.402

Smart Port ® CT Mini > Smallest profile power-injectable port currently on the market > Low-profile design ideal for chest or peripheral placement > Largest septum diameter of any power-injectable peripheral port currently on the market > One-step locking mechanism means fast, simple and secure procedures > Carbothane® catheter offers balance between softness and strength coupled with greater drug compatibility > Footprint (in): X: 0.680, Y: 0.940*; Height (in): 0.424; Septum Diameter (in): 0.402 * X is horizontal and Y is vertical with the stem always vertical.

>> SMART PORT ® PATIENT EDUCATION PACKET When a Smart Port® power-injectable port is implanted, each patient receives an education packet—including an information booklet, ID card, key ring card and ID bracelet.


>> ROUND CHAMBER Design allows fluid to reach all surfaces in the chamber, helping eliminate dead spaces, resist sludge build-up, and reduce occlusions and infections. >> OFF-SET OUTLET Set at a tangent rather than perpendicularly, it helps to create a flushing action within the port to hyper cleanse the entire chamber leading to decreased sludge build-up and a reduced rate of occlusions. Complications noted and interventions taken during the use of either a Vortex® port with Vortex® port technology or conventional port in oncology patients.1 Use of Vortex® port technology results in an average savings per patient of $1,224 over conventional ports.2

1 2

Vortex® Port

Conventional Port

Total port occlusion

0

9

Partial port occlusion (infuse but not aspirate)

57

141

Occlusions as % of total access attempts

7%

26%

Repositioned needle

39

91

Changed position with cough or deep breath

55

131

Used extra flush solution

51

104

Instilled urokinase

8

15

Surgical removal of port

0

4

Interventions as % of total access attempts

19%

62%

Stevens B, Barton SE, Brechbill M, et. al. A Randomized, Prospective Trial of Conventional Vascular Ports vs. The Vortex “Clear-Flow” Reservoir Port in Adult Oncology Patients. JVAD 2000; (Summer). Third party verification by Pinnacle Healthcare Management.

Identifying a Smart Port Power-Injectable Port ®

Smart Port® power-injectable ports can be identified by the Smart Angle® identifier technology on the CT and CT Low-Profile models. The CT engraving on all models can be identified through Chest X-Ray or CT Scout Scan.


SMART PORT ® CT Description

Introducer Size (Fr.)

Part #

Material Port Body/Catheter

Catheter ID/OD (mm)

Port

O.D.

Length

Int Vol

(cm)

(mL/cm)

(Fr.)

Int Vol (mL)

Detached silicone catheter

8

CT75STSD

Titanium/Silicone FluoroMax®

1.4/2.5

7.5

66

0.015

0.7

Detached polyurethane catheter

8

CT80STPD

Titanium/Polyurethane FluoroMax®

1.5/2.7

8

66

0.020

0.7

Detached silicone catheter

10

CT96STSD

1.6/3.2

9.6

66

0.020

0.7

Detached silicone catheter

8

CT75STSD-NF

1.4/2.5

7.5

66

0.015

0.7

Detached polyurethane catheter

8

CT80STPD-NF

Titanium/Polyurethane FluoroMax®

1.5/2.7

8

66

0.020

0.7

Detached silicone catheter

10

CT96STSD-NF

Titanium/Silicone FluoroMax®

1.6/3.2

9.6

66

0.020

0.7

Attached silicone catheter

8

CT75STSA

Titanium/Silicone FluoroMax®

1.4/2.5

7.5

66

0.015

0.7

Attached polyurethane catheter

8

CT80STPA

Titanium/Polyurethane FluoroMax®

1.5/2.7

8

66

0.020

0.7

Attached silicone catheter

10

CT96STSA

Titanium/Silicone FluoroMax®

1.6/3.2

9.6

66

0.020

0.7

ID/OD

O.D.

Length

Int Vol

(cm)

(mL/cm)

Int Vol

1.4/2.2

6.6

55

0.016

0.4

ID/OD

O.D.

Length

Int Vol

(cm)

(mL/cm)

Int Vol

6.6

55

0.016

non filled suture holes non filled suture holes non filled suture holes

Titanium/Silicone FluoroMax® Titanium/Silicone FluoroMax®

SMART PORT ® CT LOW-PROFILE Description

Introducer Size (Fr.)

Part #

Material Port Body/Catheter

Catheter (mm)

Detached polyurethane catheter

7

CT66LTPD

Titanium/Carbothane®

Part #

Material Port Body/Catheter

(Fr.)

Port (mL)

SMART PORT ® CT MINI Description

Introducer Size (Fr.)

Catheter (mm)

Detached polyurethane catheter

7

CT66PTPD

Titanium/Carbothane

®

1.4/2.2

(Fr.)

Port (mL)

0.3

IMPORTANT RISK INFORMATION The following is a brief summary of important risk information for the Smart Port® power-injectable port line. For detailed information on the categories referenced, please consult the instructions for use packaged with each device. Observe all instructions prior to use. Failure to do so may result in patient complications.

medications, nutritional supplementation, fluids, blood, blood products, sampling of blood and power injection of contrast media for imaging. MP and LP models: Use of the a non Y site LifeGuard Safety Infusion Set (size = 20Ga or 19Ga) is indicated for power injection of contrast media. For power injection of contrasdt media, maximum recommended infusion rate is 5ml/sec.)

INDICATION FOR USE: The Smart Port® CT power injectable port line is indicated for any patient requiring repeated access of the vascular system for delivery of

CONTRAINDICATIONS: Smart Port® CT should not be implanted in the presence of known or suspected infections, bacteremia, septicemia and peritonitis, or in patients who have exhibited prior intolerance to the

materials of construction, or patients whose body size or tissue is insufficient to accommodate the size of the port or catheter. WARNINGS AND PRECAUTIONS: Please see package insert for complete list of warnings and precautions. POTENTIAL COMPLICATIONS: Consult package insert for a complete list of potential complications. CAUTION: Federal (USA) law restricts these devices to sale by or on the order of a physician.

USA > 603 Queensbury Avenue, Queensbury, NY 12804 > tel: 800-772-6446 or 518-798-1215 > fax: 518-798-1360 International > Building 2000, Beach Drive, IQ Cambridge, Waterbeach, Cambridge, CB25 9TE > United Kingdom tel: +44 1223 729 300 > fax: +44 1223 729 349 www.angiodynamics.com AngioDynamics, SmartPort, Vortex, Smart Angle and FluoroMax are registered trademarks of AngioDynamics, Inc. Covered under U.S. Patent 5,951,512. U.S. and foreign patents pending.

© 2010 AngioDynamics, Inc. MLC 220 Rev F 01/10