PORTFOLIO OF SELECTED PROJECTS WINSTON LIEW 2022
TIMELINE OF EDUCATION AND WORK EXPERIENCE Graduate of Architecture Hassell
Graduate of Architecture Bureau SRH
WINSTON LIEW winston.liew1@gmail.com
Worked on several projects ranging from residential, to apartment complexes, to health and industrial buildings.
2021 - present
Worked on the conceptual stage of Brisbane Central Station producing drawings in Revit and visualisations and renders using Rhino, Photoshop, Indesign and Enscape
MASTERS OF ARCHITECTURE University of Sydney
2019
ABOUT ME:
Great design is achieved when the thinking goes from “why” to “why not”. I believe design is the problem solving tool used to improve and enrich our environment. I have found myself drawn to design my whole life but it has taken me more than a decade to piece it to together and come to this realisation. Throughout my education, I have been drawn to various disciplines ranging from languages, maths, philosophy, psychology and design. What others see in my seemingly haphazard educational background, I see as my strength. I believe design is seeing the bigger picture and drawing from many bodies of knowledge. My design career thus far has illustrated this. This portfolio is an eclectic arrangement of projects that I have completed in the past. It is as diverse as my interests. However, in all of the projects, I have sought out the underlying problems and developed holistic solutions to broach these issues. Turning problems to opportunities.
Ecole Polytechnique Federale de Lausanne Master exchange semester to Switzerland. Undertook an urban design studio, along with
Internship Sydney Metro Joined the Barangaroo Metro station team and shadowing architects in their oversight over the drawings and documentation of the station.
2017
BACHELOR OF DSESIGN IN ARCHITECTURE University of Sydney
Tsinghua University Bachelor exchange semester to China. Undertook an digital and urban studio along with history and theory subjects and Chinese language.
2015
Internship Terry Nott Architects Worked on a couple of residential projects in Fitzroy, Melbourne. Using AutoCAD to produce section drawings and plans.
BACHELOR OF SCIENCE
2013
University of Melbourne, major in Physiology studied Psychoolgy, Pathology, Neuroscience, Biology , Anatomy
AWARDS + CERTIFICATES
SOFTWARE SKILLS
Procificency in Photoshop
Illustrator
Awarded from RMIT University (2019) Completed a 4 weekend course to learn about Adobe Photoshop
InDesign
Photoshop
Recipient of the Vice Chancellor’s Travelling Scholarship Awarded from Sydney University (2020) Awarded for my exchange semester to Switzerland to study Architecture
Revit
Grasshopper
Procificency in Revit Awarded from RMIT University (2018) Completed a 4 weekend course to learn about Revit Bryan Patrick Keirnan Prize Commendation Awarded Commendation in the 2021 Bryan Patrick Keirnan Prize for Architecture for “Tank Stream Resevoir”
ArchiCAD
Rhino3D
AutoCAD
Enscape
1. 2. 3. 4. 5.
TANK STREAM BRISBANE CENT USYD GRAD SHO HOPE PAVILION SALISBURY HOU
TRAL STATION OW 2018 N USE
Render of the Sydney GPO and Tank Stream Resevoir Winston Liew, Jonathan Tong, Sean Edirisinghe 2021
TANK STREAM RESEVOIR IN A SHORT SPACE OF TIME, THE IDENTITY OF THE CITY HAS COME INTO QUESTION. COVID-19 HAS PROMPTED AN EXODUS FROM THE CITY. THE ECONOMIC ENGINE OF SYDNEY’S CBD HAS GRINDED TO A HALT. HAILING AN IRREVOCABLE SHIFT IN OUR WAY OF LIVING. HOWEVER, WITHIN THE NEXT 50-100 YEARS, THE CITY WILL UNDERGO EVEN GREATER TRANSFORMATIONS. BY 2100, AIR TEMPERATURE RISES TO 4.8% ABOVE THE GLOBAL AVERAGE. LEADING TO MORE BUSHFIRES AND POLLUTION. THERE IS AN IMMEDIATE NEED FOR THE CITY TO TRANSITION INTO A MORE HABITABLE AND SELF-SUSTAINING MODEL.
PROJECT TYPE INVOLVEMENT YEAR OF COMPLETION TEAMMATES
COMPETITION ENTRY
GROUP WORK 2020 DEC - FEB 2021
JONATHAN TONG, SEAN EDIRISINGHE
A MODEL THAT FOSTERS NATURE RATHER THAN SUPRESS IT. THE “TANK STREAM RESEVOIR” IS AN OASIS - A SANCTUARY AMIDST THE CHAOS OF THE CITY. THE PROJECT PAYS AMIDST THE CHAOS OF THE CITY. THE PROJECT PAYS HOMAGE TO THE TANK STREAM - A HERITAGE INFRASTRUCTURE LYING UNDERNEATH THE CITY. THE PROPOSAL IS SET IN 2100 WHEN THE GPO (LIKE THE REST OF THE CBD) ARE ARTIFACTS OF A CIVILISATION. ITS FUNCTION THEREFORE RETROFITTED TO BE A MARKER OF THE OASIS OF THE TANK STREAM RESEVOIR.
Site Plan of Sydney
Heritage of Tank Stream Tank Stream was a fresh water souce for First Nation Peoples, precolonisation. The stream then was converted to a sewer and then finally a storm-water drain. It has largely been forgotton in modern times. The stream spans upsteam from Circular Quay to Hyde park - wherein a reservoir once existed.
N
60M
Colony was in drought. Water tanks were carved out of the sandstone Animals were not allowed to graze within a 15m distance from the stream
1790
1791
Enclosed with a fence to prevent tresspass and livestock entering
1795
ees)
1810
Cut off of drains to reduce polluted stormwater
1832
Tank stream converted to sewer system
degrees)
ees)
Tank stream was disallowed for drinking by Govenor Brisbane
City Council given charge of tank
1826
1842
Construction of
1850 Circular Quay begins
Tank stream becomes a sewage
1857 Tank Stream is drained
1860 and converted to
storm water catchment
Timeline of Tank Stream
-50
100 Current policies (2.7 - 3.1 degrees) 50
Pledges & Targets (2.3 - 2.6 degrees) Optimistic net zero targets (2.1 degrees)
0
2 deg consistent (1.6 - 1.7 degrees)
2090
-5
Depth in meters
2M Section Detail of the roof structure
4M Lonngdatudinal Section
2100
-15
2090
MAY
2080
APRIL
JUNE
AUGUST
MARCH
JULY
FEBRUARY
JANUARY
1810
Cut off of drains to reduce polluted stormwater
-20
Steady state temperature of ground
-25 Tank stream was disallowed for -30 drinking by Govenor Brisbane
1826
10
15
1832
20 Tank stream converted to sewer system
1842
Construction of
Steady state temperature of ground
Tank stream becomes a sewage
1857 Tank Stream is drained
1860 and converted to 15
20
25
Temperature in degrees celcius
30
25
Temperature in degrees celcius
1850 Circular Quay begins
-20
10
Curved in-situ concrete flooring with steel rebars
2070
1795
-15
-30
Concrete piers reaching down to solid foundation
Enclosed with a fence to prevent tresspass and livestock entering
-10
-25
1200 mm deep steel trusses
2060
-10
City Council given charge of tank
depth of MCCP
Concrete panel formwork
1791
2050
MAY
2080
APRIL
2070
JUNE
2060
AUGUST
2050
JULY
2040
MARCH
0
2030
FEBRUARY
2020
JANUARY
2010
NOVMEBER
2000
DECEMBER
1990
In-situ concrete with steel rebars
1790
2040
depth of MCCP
Baseline (4.1 - 4.8 degrees)
1.5 deg consistent (1.3 degrees)
N Ground Plan
2030
150
-50
N Underground Plan
Animals were not allowed to graze within a 15m distance from the stream -5
Depth in meters
Global greenhouse gas emissions GtCO2e / year
Warming projected by 2100
8M
2020
0
200
8M
2010
Colony was in drought. Water tanks were carved out of the sandstone
NOVMEBER
Emissions and expected warming based on pledges and current policies
2000
DECEMBER
1990
2100 WARMING PROJECTIONS
storm water catchment
30
Render of Brisbane Central Arcade Winston Liew 2022
BRISBANE CENTRAL BRISBANE CENTRAL STATION IS AN ICONIC CIVIC BUILDING THAT LIES IN THE HEART OF THE CENTRAL BUSINESS DISTRICT. AS THE MAIN TRANSPORT NODE IN THE CITY, IT SERVES IT’S UTILITY FUNCTION AS A STATION BUT ALSO A CIVIC FUNCTION AS A MEETING SPOT AND HUB OF COMMERCIAL ACTIVITY.
PROJECT TYPE
WORK
INVOLVEMENT
DRAFTING & DOCUMENTATION
YEAR OF COMPLETION COMPANY
ONGOING HASSELL
DURING MY INTERNSHIP, I WAS ASSIGNED TO THE BRISBANE CENTRAL TEAM AT HASSELL STUDIOS BRISBANE. AS THE PROJECT WAS IN THE EARLY STAGES OF DEVELOPMENT, I WAS TASKED WITH DEVELOPING VARIOUS EARLY STAGE DRAWINGS AND DOCUMENTATION.
NOTE: WITH THE ANNOUNCEMENT OF THE 2032 OLYMPICS TO BE HELD IN BRISBANE, THERE IS A NEED THE DRAWINGS AND RENDERS FEATURED IN THIS PORTFOLIO ARE SOLELY MY OWN WORK. THE DESIGN IS ALTERED TO REVITALISE THE CITY - THEREBY ENTAILING FOR THIS PORTFOLIO TO MAINTAIN THE PRIVACY OF THE A NEEDED A MUCH NEEDED TRANSFORMATION ACTUAL WORK CONDUCTED BY HASSELL WHILE SHOWTHIS CENTRAL NODE OF THE CITY INTO A WORLD- CASING MY SKILLSETS WITH REVIT, ENSCAPE AND ADOBE PHOTOSHOP AND INDESIGN . CLASS STRUCTURE.
View of the station from ANZAC square Winston Liew 2022
Concourse Arcade Heritage Facade 1 : 500
© Copyright of this drawing is vested in Hassell Ltd. This drawing is an uncontrolled copy. Unless noted otherwise 4. This drawing must be read in conjunction with all relevant contracts, specifications and drawings
BRISBANE CENTRAL STATION BRISBANE CBD
3. All dimensions shall be verified on site before proceeding with the work. Hassell shall be notified in writing of any discrepancies. 2.
CONSULTANT
REFERENCE
NORTH
PROJECT
All dimensions are in millimeters unless noted otherwise
1. Do not scale drawing. Written dimensions govern
NOTES
SK_9028
DRAWING NO. Approver
CONCOURSE PLAN PROPOSED
APPROVED
DRAWING TITLE
BROOKFIELD
REV DESCRIPTION
DATE
REVIEWED Checker
STATUS
CLIENT
Ann St Heritage Facade 1 : 500
Hassell LTD ABN 24 007 711 435 Level2, Pier 8/9,23 Hickson Rd Sydney NSW 2000 Australia T +61 2 9101 2000 F +61 2 9101 2100 sydney@hassellstudio.com Nominated Architects NSW: Tony Grist 5350 Glenn Scott 6842 Ross de la Motte 7398
2
A_0107
CONSULTANT
4m
CONSULTANT
2
2
A_0107
1
1 : 500
0
Concourse Arcade Heritage Facade
Hassell LTD ABN 24 007 711 435 36 Warry Street Fortitude Valley Brisbane QLD 4006 Australia T +61 7 3914 4000 F +61 7 3914 4100 brisbane@hassellstudio.com
1
A_0201
1:50
1
A_0201
NORTH
REFERENCE
NOTES
REV DESCRIPTION
Ann St Heritage Facade 1 : 500 0m
1m
Hassell LTD ABN 24 007 711 435 Level2, Pier 8/9,23 Hickson Rd Sydney NSW 2000 Australia T +61 2 9101 2000 F +61 2 9101 2100 sydney@hassellstudio.com Nominated Architects NSW: Tony Grist 5350 Glenn Scott 6842 Ross de la Motte 7398
2m
3m
4m
1. Do not scale drawing. Written dimensions govern 2. All dimensions are in millimeters unless noted otherwise 3. All dimensions shall be verified on site before proceeding with the work. Hassell shall be notified in writing of any discrepancies. 4. This drawing must be read in conjunction with all relevant contracts, specifications and drawings This drawing is an uncontrolled copy. Unless noted otherwise © Copyright of this drawing is vested in Hassell Ltd.
NORTH
REFERENCE
0m
1m
2m
3m
4m
NOTES 1. Do not scale drawing. Written dimensions govern 2. All dimensions are in millimeters unless noted otherwise 3. All dimensions shall be verified on site before proceeding with the work. Hassell shall be notified in writing of any discrepancies. 4. This drawing must be read in conjunction with all relevant contracts, specifications and drawings This drawing is an uncontrolled copy. Unless noted otherwise © Copyright of this drawing is vested in Hassell Ltd.
DATE
CLIENT BROOKFIELD
STATUS
REVIEWED Checker
SCALE @ A3 1 : 500
PROJECT BRISBANE CENTRAL STATION
DRAWING TITLE HERITAGE FACADE ELEVATIONS
APPROVED Approver
PROJECT NO. 14812
DRAWING NO.
REV NO.
BRISBANE CBD
SK_9020
REV DESCRIPTION
DATE
CLIENT BROOKFIELD
STATUS
REVIEWED Checker
SCALE @ A3 1 : 500
PROJECT BRISBANE CENTRAL STATION
DRAWING TITLE HERITAGE FACADE ELEVATIONS
APPROVED Approver
PROJECT NO. 14812
DRAWING NO.
REV NO.
BRISBANE CBD
SK_9020
UP
NORTH
REFERENCE
CONSULTANT Hassell LTD ABN 24 007 711 435 36 Warry Street Fortitude Valley Brisbane QLD 4006 Australia T +61 7 3914 4000 F +61 7 3914 4100 brisbane@hassellstudio.com
NOTES 2.
REVIEWED Checker
SCALE @ A1 1 : 250
PROJECT
DRAWING TITLE
APPROVED
BRISBANE CENTRAL STATION BRISBANE CBD
PLATFORM FLOOR PLAN PROPOSED
Approver
PROJECT NO. 14812
This drawing is an uncontrolled copy. Unless noted otherwise
DRAWING NO.
REV NO.
© Copyright of this drawing is vested in Hassell Ltd.
SK_9029
All dimensions are in millimeters unless noted otherwise
3. All dimensions shall be verified on site before proceeding with the work. Hassell shall be notified in writing of any discrepancies.
0 1:50
1
2
4m
CLIENT
STATUS
1. Do not scale drawing. Written dimensions govern
4. This drawing must be read in conjunction with all relevant contracts, specifications and drawings
REV DESCRIPTION
DATE
BROOKFIELD
The Tin Sheds Gallery Exhibition University of Sydney 2018
GRAD SHOW 2018 THE GRAD EXHIBITION SIGNIFIES THE FINAL STUDIO PROJECTS OF THE GRADUATING MASTERS AND BACHELORS STUDENTS AT THE UNIVERSITY OF SYDNEY. THE DESIGN AND CONSTRUCTION OF THE GRADUATE EXHIBITION IS OFFERED AS AN ELECTIVE TO THE COHORT OF DESIGN STUDENTS. IN MY FINAL YEAR OF MY BACHELOR STUDIES, I JOINED THE DESIGN TEAM OF THE USYD GRAD SHOW AS THE DESIGN LEAD OF THE EXHIBITION. IN A TEAM OF 4, WE CONCEPTUALISED AND DETAILED THE CONSTRUCTION OF THE THEME OF THE EXHIBIT.
PROJECT TYPE INVOLVEMENT YEAR OF COMPLETION TEAMMATES
BUILT
GROUP WORK 2018 JUN - NOV 2018
USYD GRAD EXHIBITION TEAM
THE THEME REVOLVED AROUND THE ERGONOMIC DISPLAY OF PROJECTS AND THE FLOW OF MOVEMENT IN THE SPACE. THE UNIVERSITY TYPICALLY DRAWS CROWDS UP TO 3000 INDIVIDUALS ON THE OPENING NIGHT AND THE LAYOUT AND SPACING OF THE INSTALLATIONS ENCOURAGED FLUID MOVEMENT AND REDUCED BOTTLENECKS THAT MAY HAVE HAPPENED OTHERWISE. THE PANELS WERE DOUBLE SIDED AND HUNG ON A ALUMINIUM ROD THAT SPANNED THE ROOM. FEATURED AT EYE LEVEL TO THE VISITORS AND IN THE PERIPHERY TO ENCOURAGE A WANDERING CURIOSITY DOWN THE EXHIBITION AISLES.
SECTION DETAILS OF INSTALLATIONS
c 1010
600
1025
300
300
600
300
75
1040
75
75
1200
2730
1200
2075
2730
a
2730
b
30
30
350
350
450 200
750
750
300
1300
1700 300
300
300
660
915
480
e
300 480
d
75
440
1500
2075
2700
1200
2075
2700
1200
30
30
490
350
350
900
950
450
450
750
950
1500
750
700
440
2075
c e
d 450
300
b
a
f
e
f
2730
N
1M
5M
CONSTRUCTION DETAILING
1.
3.
2.
4.
5.
2mm THICK STEEL WIRE ROPE 2mm THICK STEEL WIRE ROPE
COPPER FERRULE TO HELP CREATE LOOP
COPPER FERRULE TO HELP CREATE LOOP
26mm THICK WOODEN DOWEL 500mm LONG 26mm THICK WOODEN DOWEL 500mm LONG
HOPE
Project Type
Involvement
Year of Com
Unit Co-ordi
The studi Expo 202 the aim is and inspir future. The can reflec ic ceiling o designed climate ch is an arch about the of the glo formance
Render of Hope Pavilion interior Winston Liew 2019 Interior render of the Hope Pavilion for Dubai 2020 World Expo Sustainable Masters studio 2019
HOPE PAVILION THE MILLENIALS GREW UP IN AN ERA OF HYPERAWARENESS OF THE DIRE AND STARK NATURE OF THE CLIMATE CRISIS. EVERY YEAR SEEMINGLY BRINGING NEW BREAKING CLIMATE NEWS ABOUT ANOTHER ENDANGERED SPECIES / A DEFORESTATION IN ANOTHER PART OF THE GLOBE / RISING SMOKE AND POLLUTION IN THE SKY / RAIN TURNED ACIDIC / DROUGHT / FLOODING / RISING SEA LEVELS. THE CULMINATION OF INFORMATION DISHEARTENING AND FEEDING APPREHENSION TOWARDS THE FUTURE OF THE PLANET. THE PAVILION DESIGN FOR THE DUBAI EXPO 2020
PROJECT TYPE INVOLVEMENT YEAR OF COMPLETION TEAMMATES
SUSTAINABILITY STUDIO
GROUP WORK 20219 FEB - JUN 2019
MELANIE CHOW, TIFFANY CHAN
AIMS TO SHOWCASE THE COLLECTIVE SPIRIT OF HUMANITY AND INSPIRE HOPE ABOUT THE FUTURE. HUNDREDS OF PAPER WISHES FLOAT AND SWIRL IN THE CEILING ABOVE THE PAVILION SPACE - THE HOPE PAVILION IS A PHYSICAL REMINDER OF HOW IDEAS AND RESOLVE IS THE PRECURSOR OF POSITION ACTION. MAKING A STEP IN THE RIGHT DIRECTION AND FOCUSSING ON WHAT WE CAN DO IN SPITE OF THE DIRE CIRCUMSTANCES WE AREBORN INTO.
IT WAS THE FIRST EXPO I SAW EVER. A DAY I CAN’T FORGET
the sun was setting as i approached the pavilion. IT WAS SEEMED DIFFERENT FROM THE OTHER PAVILIONS I VISITED THAT DAY
THE PAVILION MADE ME REFLECT. I STARTED THINKING ABOUT WHAT I WANTED MY FUTURE TO BE LIKE...
AS I ENTERED I SAW thousands upon thousands of wishes floating overhead. a sea of wishes SWIRLING ABOVE ME...
WHEN I DECIDED UPON IT. I HELD IT SOFTLY IN THE PALM OF MY HAND.
and up....
TWIRLING UP...
IT TWIRLED UP TOWARDS THE SKY...
and like that...
AND THEN I LET IT FLY UP
OR DA
CED TO 1:14. TOP OF DRIVEWAY RAMP LOWERED FROM RL M HEADROOM CLEARANCE FOR BOTH LEVELS OF CAR
M RL 1.85 to RL 1.37, ALLOWING 2500MM FROM POINT OF CAR CIFIED IN CAR STACKER ENGINEER DRAWINGS. OR SIDE ACCESS. UTSIDE GARAGE DOORS FOR GARAGE ACCESS FROM LOBBY
ED FROM HINGED TO SLIDING POCKET DOOR. FENCE AND DRIVEWAY GATE ARE 900MM HIGH, TO COMPLY
DED, TO BE OF THE SAME STYLE AS FRONT FENCE. ON AMENDED TO REFLECT LOWERED CAR STACKER PIT. LLOW FOR ADDITIONAL STEPS. RN BOUNDARY AMENDED AS PER AMENDED RAMP LEVELS.
NT AND
uth Wales 2029
AN N PLAN LAN
& WEST H & SOUTH
ON
ES
DATE
NTS 1:500 1:100 1:100 1:100 1:100 1:100 1:100 1:100 1:100 1:20 1:50 1:100 NTS 1:200, 1:500 1:200 1:200 1:200
19/11/2020 19/11/2020 19/11/2020 19/11/2020 19/11/2020 19/11/2020 19/11/2020 19/11/2020 19/11/2020 19/11/2020 19/11/2020 19/11/2020 19/11/2020 19/11/2020 19/11/2020 19/11/2020 19/11/2020 19/11/2020
DEVELOPMENT APPLICATION
DABLE AREA CALCULATION ROUND FLOOR & LEVEL 1 A CALCULATION MENT PLAN
SCALE
Render of front facade of Salisbury House Bureau SRH 2021
7/10/20 19/11/20
GENERAL NOTES
ALL CONSTRUCTION TO COMPLY AT MINIMUM W/ BCA CLAUSES & AUSTRALIAN STANDARDS
1. ALL WORKS TO BE IN ACCORDANCE WITH THE BUILDING CODE OF AUSTRALIA, AUSTRALIAN STANDARDS, STATUTORY REGULATIONS AND LOCAL AUTHORITY REQUIREMENTS, INCLUDING CONDITIONS OF CONSENT. 2. DO NOT SCALE OFF THIS DRAWING. ONLY USE DIMENSIONS PROVIDED. 3. CONTRACTOR TO VERIFY ALL DIMENSIONS ON SITE PRIOR TO COMMENCING WORK. 4. MHNDU DRAWINGS TO BE READ IN CONJUNCTION WITH ALL CONTRACT DOCUMENTS FROM ALL CONSULTANTS. 5. CONTRACTOR TO NOTIFY MHNDU OF ANY DISCREPENCIES, DIMENSIONAL INCONSISTENCIES, OR THE NEED FOR CLARIFICATION PRIOR TO MANUFACTURING. 6. CONTRACTOR TO ENSURE CONSISTENCY BETWEEN MATERIALS IS MAINTAINED 7. MHNDU TO REVIEW ALL CONTRACTOR'S DETAILED DRAWINGS / SETTING OUT PRIOR TO CONSTRUCTION. 8. PROGRESS WORK TO BE VERIFIED AGAINST DRAWINGS FOLLOWING EXECUTION AND ARCHITECT TO BE NOTIFIED OF ANY DISCREPANCIES PRIOR TO CONTRACTOR PROCEEDING WITH NEXT TRADE.
CLAUSE B 1.4 MATERIAL & FORMS CONSTRUCTIONS SPEC. C1.1 FIRE RESISTING CONSTRUCTION SPEC. C1.10 FIRE HAZARD PROPERTIES SPEC. C.11 PERFORMANCE OF EXTERNAL WALLS IN A FIRE CLAUSE C2.6 VERTICAL SEPARATION OF OPENINGS IN EXTERNAL WALL CLAUSE C2.12 SPEARATION OF EQUIPMENT CLAUSE C2.13 ELECTRICITY SUPPLY SYSYEM CLAUSE C.3 ACCEPTABLE METHODS OF PROTECTION (OF OPENINGS) CLAUSE C3.8 OPENING IN FIRE ISOLATED EXITS CLAUSE C3.15 OPENING FOR SERVICE INSTALLATIONS CLAUSE D1.10 DISCHARGE FROM EXITS CLAUSE D2.7 INSTALLATIONS IN EXITS AND PATHS OF TRAVEL CLAUSE D2.13 GOINGS AND RISERS CLAUSE D2.14 LANDINGS CLAUSE D2.15 THRESHOLDS CLAUSE D2.16 BALUSTRADES
CLAUSE D2.17 HANDRAILS CLAUSE D2.21 OPERATION OF LATCH CLAUSE D2.23 SIGNS ON DOORS CLAUSE D3.2 GENERAL BUILDING ACCESS REQUIREMENTS CLAUSE D3.3 PARTS OF BUILDING TO BE ACCESSIBLE CLAUSE D3.6 IDENT. OF ACCESSIBLE FACIL/SERV/FEATURES CLAUSE D3.8 TACTILE INDICATORS CLAUSE F1.7 WATERPROOFING OF WET AREAS CLAUSE F1.9/F1.10 DAMP PROOFING CLAUSE 2.5 CONSTRUCTION OF SANITARY COMPARTMENTS PART F4 LIGHTING AND VENTILATION CLAUSE F5.4 SOUND INSULATION OF FLOORS CLAUSE F5.5 SOUND INSULATION OF WALLS CLAUSE F5.6 SOUND INSULATION OF SERVICES CLAUSE F5.7 SOUND INSULATION OF PUMPS
ARTIFICIAL LIGHTING: TO COMPLY WITH BCA PART CLAUSEF4.4 & AS1680 BALUSTRADE HEIGHTS: TO COMPLY WITH BCA CLAUSE D2.16 DRAINAGE GUTTERS & DOWNPIPES: TO COMPLY WITH AS/NZS 3500 3.2 ENERGY EFFICIENCYGLAZING: TO COMPLY WITH J2 OF BCA FIRE SERVICES: TO COMPLY WITH SECTION E OF BCA HOT WATER: SYSTEMS TO COMPLY WITH PART J7 OF BCA MASONRY: TO COMPLY WITH AS3700 MECH/ELEC/HYDRAULIC: BCA CLAUSE C3.15 & AS1530 4-2005 MECHANICAL AIRCONDITIONING: TO COMPLY WITH PART J5 OF BCA MECHANICAL EXHANUST VENTILATION: TO COMPLY WITH AS1668 & AS68.2 SMOKE ALARMS: TO COMPLY WITH BCA PART CLAUSE & SPEC E2.2 & AS3786 PENETRATIONS: THROUGH FIRE RATED CONSTRUCTION FOR MECH/ELEC/ HYDRAULIC PENETRATIONS TO COMPLY WITH BCA CLAUSE C3.15 & AS1530 4-2005 SOUND TRANSMISSION: TO COMPLY WITH PART5 OF BCA STAIR CONSTRUCTION: TO COMPLY WITH BCA CLAUSE D2.13 STAIR CONSTRUCTION: TO COMPLY WITH BCA CLAUSE D2.13 WATERPROOFING OF WET AREAS: TO COMPLY WITH AS3740
BASIX COMMITMENTS (ALL OTHER BASIX COMMITMENTS AS PER BASIX CERTIFICATE AND STAMPED PLANS) WATER OPTIONS SHOWERHEADS: TOILETS: KITCHEN TAPS: BATHROOM TAPS: RAIN WATER TANK: POOL/SPA: COLLECT RUN OFF AREA: LANDSCAPED AREA TO IRRIGATE: ENERGY OPTIONS COOLING & HEATING: VENTILATION:
WATER HEATING: ENERGY EFFICIENT LIGHTING: COOK TOPS:
3 STAR 4 STAR 6 STAR 6 STAR 4000 L 20 kL 180 sqm Unit A: 188.15 sqm, with 119.35 sqm lowwater use species; Unit B: 6.2 sqm 1-phase air conditioning, EER 2.5 & Day/ Night zoned to Living & Bed areas. Exhausts ducted & sealed; interlocked to light, to Bathroom, Laundry & Kitchen areas; manual 'on/off' in Kitchen area; no mechanical ventilation to common areas. 3.0 'Star', gas instantaneous. Compact fluorescent/LED to all rooms and common areas. Gas cook top, electric oven.
REFRIGATOR SPACE: CLOTHES DRYING LINES: ALTERNATIVE SUPPLY: POOL/SPA: LIFT: THERMAL COMFORT OPTIONS ROOF: CEILINGS: EXTERNAL WALLS: INTERNAL WALLS: FLOORS: GLAZING SPEC & TYPE:
Well ventilated. Indoor & outdoor lines installed. Photovoltaic, 0.8 kW peak. 10.74 sqm; no pool heating; timers to pump. Hydraulic. Metal deck roof + R1.0 insulation blanket to underside; concrete terrace; 'light' colour. Minimum R2.5 insulation to all ceilings with roof or terrace above; rated with sealed exhaust ventilation; not rated with down-lights. Timber-clad concrete block (190mm) + R2.0 insulation; 'dark' colour. Plasterboard on stud within dwellings Concrete floors throughout; R1.5 insulation to floors with 'Garage' below; timber, carpet & tile coverings to floors (as per plans) AFRC: Uw = 3.8 SHGC = 3.4, for stacker doors. eg. Aluminium-framed double-glazed 'Low-e' glass. AFRC: Uw = 5.6 SHGC = 0.36, for casement windows. eg. Aluminium-framed single-glazed 'Low-e' glass. AFRC: Uw = 5.6 SHGC = 0.41, for non-casement glazing. eg. Aluminium-framed single-glazed 'Low-e' glass. AFRC: Uw = 4.2 SHGC = 0.72, for skylight glazing, 100% shading eg. Aluminium-framed double-glazed clear glass with external shading louvres
NOTES: EX FFL RL
ARCHITECT: EXISTING RL OF FINISHED FLOOR LEVEL REDUCED LEVEL BOUNDARY EX BUILDING TO BE DEMOLISHED DCP SETBACK CONTROL LEP 9.5M HEIGHT CONTROL LEP 10.5M HEIGHT CONTROL FOR RFB
EX TREE TO REMOVE EX TREE TO RETAIN
PROJECT ADDRESS:
31 Salisbury Road, New South Wales Rose Bay 2029
DRAWN BY: SL
CHECKED: LH
SCALE: NTS @A1
PROPOSED TREE PROPOSED LANDSCAPE
DRAWING TITLE:
ISSUE DATE:
REVISION:
COVERPAGE
19/11/20
B
PROJECT NUMBER:
DWG NUMBER:
19-071
DA 0000
SALISBURY HOUSE
PROJECT TYPE
WORK
INVOLVEMENT
DOCUMENTATION AND DRAFTING
YEAR OF COMPLETION COMPANY
SALISBURY HOUSE IS A DESIGN FOR A YOUNG FAMILY OF 4 IN SYDNEY, NEW SOUTH WALES. THE BRIEF OF THE PROJECT WAS TO CREATE A COSY SPACE THAT BLENDS INTO ITS LEAFY SURROUNDINGS AND INSPIRES “MOMENTS OF CONTEMPLATION” IN DAILY LIVING. THE DESIGN IS PREDOMINATELY DARK TIMBER CLADDING REMINISCENT OF SCANDINAVIAN ARCHITECTURE. THE WARMTH OF THE WOODEN STRUCTURE ASSIMILATES ITSELF INTO THE VERNACULAR OF THE AREA. COMPLEMENTING THE LARGE OAK TREES FOUND IN THE FRONT AND BACK OF THE HOUSE.
IN DEVELOPMENT BUREAU SRH
PLAN 990
700
1,750
F
990
700
990
1,410
2,226
F
1,410
550
1,850
1,850
WB01
WB02
GARAGE
990
700
990
GARAGE
WB03
WB04
BEDROOM
WB05
BEDROOM
600
1,300 WB06
LIVING
6,670 WB08
WB07
LIVING
LIVING
WB09
DINING
WB10
DINING
3,190
BEDROOM
1,300 WB12
WB11
MASTER BEDROOM HINGED
BATHROOM
WB13
WB14
WB15
WB16
WB17
WB18
MASTER W.I.R
BATHROOM
BATHROOM
BATHROOM
MASTER BEDROOM
HINGED
HINGED
FIXED
FIXED
FIXED
HINGED
HINGED
HINGED
HINGED
HINGED
FIXED
FIXED
HINGED
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
HEIGHT WIDTH FRAME
2,650 990 ALUMINIUM
2,650 990 ALUMINIUM
1,750 550 ALUMINIUM
1,750 990 ALUMINIUM
1,750 +11,450 1,850 ALUMINIUM 2 ROOF
3,500 600 TIMBER
3,500 600 TIMBER
0 0 ALUMINIUM
1,750 1,850 ALUMINIUM
1,750 990 ALUMINIUM
1,750 700 ALUMINIUM
1,750 700 ALUMINIUM
1,750 990 ALUMINIUM
1,750 700 ALUMINIUM
1,750 990 ALUMINIUM
750 1,410 ALUMINIUM
750 2,226 ALUMINIUM
1,950 990 ALUMINIUM
POWDER COAT
POWDER COAT
POWDER COAT
POWDER COAT
POWDER COAT
<Undefined>
<Undefined> WEATHER SEALED YES U= 5.6, SHGC = 0.36 125mm opening as per BCA restriction
NON-POWDER COAT
NON-POWDER COAT
POWDER COAT
<Undefined>
<Undefined>
<Undefined>
<Undefined>
WEATHER SEALED
WEATHER SEALED
WEATHER SEALED
WEATHER SEALED
YES
YES
<Undefined> WEATHER SEALED YES
<Undefined>
WEATHER SEALED
NO
<Undefined> WEATHER SEALED YES
<Undefined>
WEATHER SEALED
NO
YES
YES
U= 5.6, SHGC = 0.36
U= 5.6, SHGC = 0.36
<Undefined>
<Undefined>
125mm opening as per BCA restriction
125mm opening as per BCA restriction
-
-
POWDER COAT
POWDER COAT POWDER COAT
<Undefined>
<Undefined> WEATHER SEALED NO U = 5.6, SHGC = U = 5.6, SHGC = 0.41 0.41
U = 5.6, SHGC = 0.41
NOTES
-
-
-
POWDER COAT
WINDOW SCHEDULE 1:1
01
W01
BATHROOM
POWDER COAT
W02
<Undefined> <Undefined> WEATHER WEATHER SEALED SEALED YES YES U= 5.6, SHGC = U= 5.6, SHGC = 0.36 0.36 125mm opening as 125mm opening as per BCA restriction per BCA restriction
U= 5.6, SHGC = 0.36
U= 5.6, SHGC = 0.36
-
125mm opening as per BCA restriction
125mm opening as per BCA restriction
YES
W01
BEDROOM
U = 5.6, SHGC = 0.41
WEATHER SEALED
U= 5.6, SHGC = 0.36 125mm opening as per BCA restriction
CAR STACKER
550
CAR STACKER
990
MASTER BEDROOM
WB20
1,850
WB21
LAUNDRY
U = 5.6, SHGC = 0.41
U = 5.6, SHGC = 0.41
U= 5.6, SHGC = 0.36
125mm opening as per BCA restriction
<Undefined>
-
125mm opening as per BCA restriction
1,850
990
700
700
990
WB22
KITCHEN
DINING
WB23
WB24
LIVING
<Undefined>
WB25 BEDROOM
WB27
BEDROOM
BATHROOM
F
3,064
700
WB26
F
RL +3,870
1,744
990
5,170
CAR STACKER
WB28
WB29
WB30
BEDROOM
BATHROOM
BATHROOM
WB31 BEDROOM
HINGED
FIXED
HINGED
HINGED
HINGED
HINGED
HINGED
HINGED
HINGED
HINGED
HINGED
FIXED
SLIDING
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
1,950 990 ALUMINIUM
1,950 550 ALUMINIUM
1,950 990 ALUMINIUM
1,950 1,850 ALUMINIUM
1,950 1,850 ALUMINIUM
1,950 990 ALUMINIUM
1,950 700 ALUMINIUM
1,950 700 ALUMINIUM
1,950 990 ALUMINIUM
1,950 700 ALUMINIUM
1,950 990 ALUMINIUM
1,750 1,744 ALUMINIUM
1,750 5,170 ALUMINIUM
POWDER COAT POWDER COAT
POWDER COAT
POWDER COAT
POWDER COAT
POWDER COAT
POWDER COAT
POWDER COAT
POWDER COAT
POWDER COAT
POWDER COAT
POWDER COAT
<Undefined>
<Undefined>
<Undefined>
<Undefined> WEATHER SEALED YES U= 5.6, SHGC = 0.36 125mm opening as per BCA restriction
<Undefined> WEATHER SEALED YES U= 5.6, SHGC = 0.36 125mm opening as per BCA restriction
<Undefined>
<Undefined> WEATHER SEALED YES U= 5.6, SHGC = 0.36 125mm opening as per BCA restriction
<Undefined>
<Undefined>
<Undefined>
<Undefined> WEATHER WEATHER SEALED SEALED YES NO U = 5.6, SHGC = U= 5.6, SHGC = 0.36 0.41 125mm opening as per BCA restriction
+11,450 2 ROOF
W01
EXTERNAL
<Undefined>
01
YES
U= 5.6, SHGC = 0.36
5,170
W06
2,000
990
1,750
700
CAR STACKER WB19
<Undefined> WEATHER SEALED
NO
2,500
W07
990
1,950
700
1,950
1,950
1,950
+4,300 0 GROUND FLOOR
1,950
W01
700
1,950
990
1,950
1,850
3,065 990
POWDER COAT
<Undefined> WEATHER SEALED
NO
SALISBURY RD
1,950
1,850
1,950
990
1,950
1,950
F
POWDER COAT
<Undefined> WEATHER SEALED
YES
+8,300 1 FIRST FLOOR
1,744 550
POWDER COAT
<Undefined>
+8,300 1 FIRST FLOOR
BATHROOM 990
POWDER COAT
WEATHER SEALED
WEATHER SEALED
WEATHER SEALED
YES
WEATHER SEALED
YES
±0
POWDER COAT -1 AHD <Undefined> WEATHER SEALED
YES
U= 5.6, SHGC = 0.36
U= 5.6, SHGC = 0.36
U= 5.6, SHGC = 0.36
125mm opening as per BCA restriction
125mm opening as per BCA restriction
125mm opening as per BCA restriction
03
YES U= 5.6, SHGC = 0.36 125mm opening as per BCA restriction
WEATHER SEALED YES
U= 5.6, SHGC = 0.36 SHORT SECTION 125mm opening as per 1:100 BCA restriction
WEATHER SEALED
WEATHER SEALED
WEATHER SEALED
YES
NO
YES
U= 5.6, SHGC = 0.36
U = 5.6, SHGC = 0.41
U= 5.6, SHGC = 0.36
125mm opening as per BCA restriction
-
-
WINDOW SCHEDULE 1:1
1
2
NB: THIS BUILDING HAS NOT BEEN DOCUMENTED AS A BIM MODEL. THE DOCUMENTS ARE STRICTLY REPRESENTATIONAL AND THEY HAVE BEEN PRODUCED SOLELY TO BE PRINTED OUT (OR CONVEYED AS PDF FORMAT) WITH THE INFORMATION CONTAINED THEREON TO BE READ OFF THE PRINTED 2D DRAWINGS (OR PDFs). THEY ARE NOT TO BE USED AS THE BASIS OF BIM-STYLE COORDINATION OR CONSTRUCTION SET-OUTS. BUREAU SRH ARE NOT LIABLE FOR THE DOCUMENTS BEING USED IN ANY MANNER EXCEPT THE MANNER DESCRIBED ABOVE, AND BUREAU SRH WILL NOT BE RESPONSIBLE FOR ANY INACCURACIES OR DISCREPANCIES WHICH RESULT FROM USING THE DOCUMENTS IN ANY OTHER WAY. IF, BY PRIOR AGREEMENT, YOU HAVE RECEIVED ELECTRONIC DRAWING FILES, THESE DOCUMENTS MUST BE COMPARED TO, AND READ IN CONJUNCTION WITH, THE LATEST ISSUE OF THE ORIGINAL HARD COPY, IN ORDER TO ENSURE THE ACCURACY OF THE INFORMATION CONTAINED AND TO FURTHER ENSURE THAT NO MODIFICATIONS HAVE BEEN MADE TO THE DOCUMENTS. THE INFORMATION CONTAINED IN THE ELECTRONIC FILES FOR THE ABOVE PROJECT HAS BEEN CREATED BY BUREAU SRH AND REMAINS THE INTELLECTUAL PROPERTY OF BUREAU SRH. WHILE BUREAU SRH HAS MADE EVERY APPROPRIATE EFFORT TO ENSURE THE ACCURACY OF THESE DOCUMENTS, IT CANNOT GUARANTEE THAT THESE DOCUMENTS CONTAIN COMPLETE AND ACCURATE INFORMATION.
3
4
5
25,158 12,100
5,450
1,730
5,878 NOT FOR CONSTRUCTION
BUREAU SRH | architecture
STUDIO 3 | 2 VERONA STREET | PADDINGTON | NSW | 2021 | AUSTRALIA | ABN: 94 115 880 834 | TEL: +61 2 9380 4666 | admin@bureausrh.com
RESIDENTIAL
NOMINATED ARCHITECT: SIMON HANSON # 6739
LEGEND:
REV DATE
31 SALISBURY RD, ROSE BAY
NAME
GENERAL: THIS DRAWING SHALL BE READ IN CONJUNCTION WITH ALL OTHER ARCHITECTURAL & CONSULTANT DRAWINGS & SPECIFICATIONS & WITH SUCH OTHER WRITTEN INSTRUCTIONS ISSUED DURING THE COURSE OF THE CONTRACT | NOTIFY ARCHITECT OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK | MATERIALS & WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE SPECIFICATION, CURRENT SAA CODES, BUILDING REGULATIONS & OTHER STATUTORY AUTHORITIES | VERIFY ALL DIMENSIONS ON SITE AND NOTIFY ARCHITECT OF ANY DISCREPANCIES | USE FIGURED DIMENSIONS ONLY | COPYRIGHT, ALL RIGHT RESERVED | THIS DRAWING IS COPYRIGHT AND CONFIDENTIAL & MAY NOT BE REPRODUCED BY ANY PERSON WITHOUT WRITTEN PERMISSION OF THE ABOVE COMPANY & IS NOT TO BE USED IN ANY MANNER PREJUDICAL TO THE INTERESTS OF THAT COMPANY | THIS DRAWING AND ATTACHED SHEET REMAIN THE PROPERTY OF BUREAU SRH PTY LTD CAD FILES: INFORMATION IN ELECTRONIC FILES TRANSMITTED REMAIN THE INTELLECTUAL PROPERTY OF BUREAU SRH. | BUREAU SRH DO NOT GUARANTEE CAD DOCUMENTS CONTAIN COMPLETE AND ACCURATE INFORMATION. | CAD DOCUMENTS MUST BE COMPARED TO, AND READ IN CONJUNCTION WITH CURRENT HARD COPY DOCUMENTS. | BUREAU SRH ARE NOT LIABLE FOR ALTERNATIONS TO CAD FILES BY THIRD PARTIES
PROJECT No:
DRAWING TITLE:
DRAWING No:
WINDOW SCHEDULE
A8100
SCALE @ A1:
12,788
REVISION:
7,875
1:1
LY
CLIENT: DANIEL K
CHECKED:
DRAWN: WL
APPROVED: SRH
LIFT OVERRUN
FIXED PRIVACY SCREEN
21070
STAGE:
CC
+4,300 0 GROUND FLOOR
RAM
NORTH ELEVATION 1:100
01
BOUNDARY
BASIX
POWDER COAT
7,776
BOUNDARY
NO
1,750
WEATHER SEALED
2,030
SEAL LOCK
BOUNDARY
FIXED
EXTERNAL
BOUNDARY
FIXED
EXTERNAL
GLAZING
HINGED PARAPET RL +11,700
MASTER BEDROOM
FIXED
INTERNAL/EXTERNAL
FRAME FINISH
BOUNDARY
F
2,226
990
15/08/2021 11:30 AM / liew / Q:\DATA\Bureau SRH Pty Ltd\Bureau SRH - Documents\0000 PROJECTS\21070_31 Salisbury Road, Rose Bay_Woollahra\B - WORKING\B.00 - DRAWINGS\B.01.01 - CURRENT DRAWING FILES\21070_31 Salisbury Rd Rose Bay.pln
ROOM
700
9,859 600
OPENING TYPE
700
1,500
990
WINDOW NUMBER
990
BOUNDARY
990
990
990
A
1,750
2,500
3,500
3,500
1,750
F
1,750
F
1,750
F
2,650
2,650
ELEVATION (VIEW FROM EXTERIOR U.N.O)
700
B
1,950
1,850
750
1,500
600
C
750
600
1,750
1,850
1,750
990
1,750
550
1,750
990
1,750
990
PARAPET RL +11,700
+11,450 2 ROOF
12,752
+11,450 2 ROOF
BALCONY
W01
KITCHEN & DINING
LNDRY W03
STAIRS W01
W04
MASTER BEDROOM
W01
+8,300 1 FIRST FLOOR
3,150
PLANTER BOX
+4,300 0 GROUND FLOOR
W02
BED
W04
W04
W04
CAR STACKER
CAR STACKER
4,000
KITCHEN & DINING
2,030
STAIRS W01
2,000
+8,300 1 FIRST FLOOR
LIFT
W05
+4,300 0 GROUND FLOOR
2,500
5,675
CAR STACKER
03 ±0 -1 AHD
LONG SECTION 1:100
SOUTH ELEVATION 1:100
5,450
12,100
FIXED PRIVACY SCREEN
LIFT OVERRUN RL +12,000
ALUMINIUM TIMBER LOOKING CLADDING
12,762
PARAPET RL +11,700
1,300
3,190
6,670
BOUNDARY
1,730
BOUNDARY
5,870
BOUNDARY
6
1,300
ALUMINIUM TIMBER LOOKING CLADDING LIFT OVERRUN +12,000
FIXED PRIVACY SCREEN
PARAPET RL +11,700 FIXED PRIVACY SCREEN +11,450 2 ROOF
F
F
3,150
3,150
F
CONC.
+8,185 CR-01
CR-01
CR-01
CR-01
CONC.
CR-01
+8,300 1 FIRST FLOOR
ROOF OVERHANG
FG
FG
T.O.W +6,100
F
3,685
4,000
ROOF OVERHANG RL +7,250
F
F
CONC.
POOL FENCE
RL +4,300 RL +4,300
RAMP 1:14
+4,300 0 GROUND FLOOR
MP 1:14
02
WEST ELEVATION 1:100
C
3
12,100
5,450
FIXED PRIVACY SCREEN ROOF RL +11,450
ALUMINIUM TIMBER LOOKING CLADDING
PARAPET RL +11,700
4
1,730
A
5
5,870
7,776
LIFT OVERRUN +12,000
+11,450 2 ROOF
1,300
BOUNDARY
2
BOUNDARY
1
B
WINDOW OVERHANG
6,670 ALUMINIUM LOOKING TIMBER CLADDING PARAPET RL +11,700
3,150
3,150
WB29
3,190
1,300
LIFT OVERRUN RL +12,000
WB30
F
F
CONC.
+8,185
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
+8,300 1 FIRST FLOOR
CONC.
F
SALISBURY RD
4,000
1800 mm METAL FENCE
T.O.W +5,297
4,000
1800mm POOL FENCE
WB15
F
GARAGE DOOR D02
RL +4,300
CONC.
GATE GROUND FLOOR RL +4,300
+4,300 0 GROUND FLOOR
04
EAST ELEVATION 1:100
METAL FENCE
GARAGE DOOR D02
GATE
BOUNDARY
CR-01
2
3
12,100
5,450
5,870
BOUNDARY
RAMP BELOW
PARAPET RL 11,700
OPEN LOUVRE ROOF LIFT OVERRUN
TREE EXISTING
RETAINING WALL BELOW
5
RAMP BELOW
PARAPET
PARAPET RL 11,700 3,125
1,730
ENTRY BELOW
FOOTPATH BELOW
ROOF FALL REFER TO STORMWATER ENGINEER DETAILS
2 SK200
ROOF RL 11,450 SKYLIGHTS
TREE EXISTING
GROUND FLOOR DECK BELOW
ROOF F
6,730
FALL
FALL
F
F
FALL
F
F
F
FALL
CONC.
ROOF FALL REFER TO STORMWATER ENGINEER DETAILS
TREE EXISTING SKYLIGHT POOL BELOW
PARAPET RL 11,700
PARAPET RL 11,700
RETAINING WALL BELOW
TREE EXISTING
TREE EXISTING
1 SK200
2 SK200
4
1 SK200
1
1:14 RAMP
RL 3,870
BED-2 FFL4,300 FSL4,270
W07
5,675
BED-1
RL 3,520
WB10
WB11
WB12
WB13
WINDOWS WB08, WB09, WB10, WB11, WB12, WB13, WB14, WB15, WB16 FACING THE BOUNDARY ARE FIXED IN METAL FRAMES. REFER TO FIRE ENGINEERING SPECS FOR DETAILS
WB14
WB15
E2 PRIVATE RESIDENTIAL LIFT - CONTROL PANEL ON THE GROUND, REFER TO LIFTSHOP SPECS FOR DETAILS
WB16
1,300
WB09
COMMUNAL GATE
WB07
ENS. FFL4,300 FFL4,240
RL 3,460
WB08
W01
GROUND FLOOR 1:100
2
3
5 5,870
WB20
WB19
W04 PRIVATE STAIRS
W03 DINING
W04
KITCHEN
D06
D05
LDRY
WB18
W05
PIRVATE LIFT
W05 WIR
MASTER TF01
FFL8,300 BATH FSL8,270 W03 D04
TF01
W03 W02
W04
6,730
D04 D04
LIVING FFL8,300 FSL8,270
D05 D04
W03
TF01 W04
W03
BED-3
FFL8,300 FSL8,240 BATH
FFL8,300 FSL8,240
TF01 W03
BED-2
W03
ENS. W01
FFL8,300 FSL8,270
WB24
W01
WB25
WB26
WB27
WB28
WB29
W01
1 SK200
WB23
WB30
BALCONY FFL8,300 FSL8,185
D04
PERGOLA
C
WB31
1,300 2 SK200
BOUNDARY
W01 WB21
W04
D09
B
4
1,730
W01 WB22
3,125
A
5,450
1 SK200
12,100
SETOUT POIN
SALISBURY RD
1
1,300
1
D05
FFL4,300 FSL4,270
FFL4,300 FSL4,270
C
WIR
1 SK200
6,670
TF01 W03
BATH
WB17
W03
W07 RL 3,440
FFL4,300 FFL4,240
TF01
RL 3,400
W07
W04
BED-3
CONC.
D04
W02
W02
DUPLO 30 CAR STACKER
D01
3,065
RL 3,870
TF01
D04
TF01 FFL4,300 FSL4,300
2 SK200
W06 W07 LNDRY
W03 STUDY
W02 D04
POOL
CONC.
D04
RL 4,300 FFL4,300 FSL4,185
D01
3,064
W05
D04
D04
1:40
5,675
DUPLO 30 CAR STACKER
D04
FFL4,300 FFL4,240 BATH
W02
DECK FFL4,300 FSL4,185 TD
D06
PRIVATE STAIRS W04
W02
E2 PRIVATE LIFT
1:14 RAMP
WB01
D03
W05
LIVING RL 5,080
1:40
WB02
W04
KITCHEN
BOUNDARY
D02
GARBAGE ROOM
DINING
LAWN FFL4,300 FSL4,185
5,870
WB03
D04
2 SK200
SLIDER DOOR ENTRY D08
5
1,730
TF01
D07
B
COLLAPSIBLE CLOTHES LINE
BBQ
WB04
3,190
DEMOLISH EXISTING LOW WALL
W01
WB05
WB06
RL 4,190
A
5,450 COMMUNAL GATE
12,100 WINDOWS WB01, WB02, WB03, WB04, WB05 FACING THE BOUNDARY ARE FIXED IN METAL FRAMES. REFER TO FIRE ENGINEERING SPECS FOR DETAILS
4
1,300
3
1 SK200
2
1
2 SK200