Local Blackfriars Block 2 Floor Plan

Page 1

Copyright of this drawing is vested in 5plus Architect and it must not be copied or reproduced without written consent. Figured dimensions only are to be taken from this drawing. DO NOT SCALE OFF THIS DRAWING ...... IF IN DOUBT ASK

All contractors must visit the site and be responsible for taking and checking all dimensions relative to their work. 5plus architects are to be advised of any variation between drawings and site conditions.

Electronic data/ drawings issued as 'read only' and should not be interrogated for measurement. All dimensions and levels should be 'read only' from those values stated in text, on the drawings

For all the wet area elevations please refer to interior designer's schedule.

B4 B5

B2 B3

D. B3. 00. 03

B1

HEALTH & SAFETY For a complete list of health and safety notes refer to drawing MP_00_1200 In addition to the usual hazards associated with works of this nature the residual hazards are:-

!

05

Cleaning/Maintenance Risk of Falling

Podium B2-04-2204

CHANNEL DRAIN

CW 06

W.B2.00.26

CW 07 CW 24

CHANNEL DRAIN

CW 23

CHANNEL DRAIN

K E Y

CHANNEL DRAIN

CW 25 W.B2.00.18 RWO

W.B2.00.19

W.B2.00.20

W.B2.00.22 RWO

W.B2.00.21

W.B2.00.23

W.B2.00.24

RWO

W.B2.00.25

W.B2.00.27 RWO

DR

RWP

B2.00.34 Stairwell

D.B2.00.21

2A

W.B2.00.01

RWP

RWP

CW 26 4, 000

Gym Entrance Lobby

B2.00.20 Apartment Reception

STAIR CORE B2

B2.00.01 1 BED L1 D.B2.00.15

B2.00.35 Lift Lobby

D.B2.00.12

2B

Riser B D.B2.00.20

RWP SS

SS

SS

SS

SS

B2.00.10 3 BED H2 G

B2.00.09 3 BED H1 G

Level: 00 FFL: +33.500

B2.00.30 Corridor

B2.00.08 3 BED H1 G

D.B2.00.28

B2.00.25 Store

SS

B2.00.29 Corridor

D.B2.00.03

AP

AP

SS

B2.00.06 3 BED J1 G

D.B2.00.31

RWO

D.B2.00.09

RWO

D.B2.00.08

RWP

W.B2.00.17

W.B2.00.11

RWO

RWP

W.B2.00.14

W.B2.00.12

SS

B2.00.22 Cinema

B2.00.04 GUEST K1

D.B2.00.07

RWO

D.B2.00.05

W.B2.00.10

W.B2.00.09

RWP

6,400

21

6,400

22

6,400

23

W.B2.00.06

2C

B2.00.03 GUEST K1

D.B2.00.04

W.B2.00.05

W.B2.00.08

W.B2.00.04 RWO

03/06/16

Issued for Tender - apartment replaces guest rooms, landscape updated & legal ownership boundary included. Access panels included.

K

08/03/16

Issued for Tender Package 02.

J

04/02/16

Amendment to core. Wall between lift and riser moved to accommodate larger lift for glass replacement strategy.

I

26/01/16

Tender Amendments - Wardrobe amended from joinery item to door and clothing rail. Store doors amended and washing machines removed (services remain). Rain water outlets indicated. Amenity space amended, gym moved to first floor, cinema, laundrette and Accessible WC added. Amenity glazing amended. Window to post room omitted, services/M+E cupboard and kitchenette added. Accessible WC added for concierge staff. Apartment entrance space revised: Revolving door and pass door added, concierge desk, feature wall, fire place, storage unit all added. Additional columns to town houses and amenity space.

W.B2.00.03 RWP RWO

W.B2.00.02

CW 17

H

06/11/15

Issued for Tender.

G

03/11/15

Issued for Information and Comment.

F

21/09/15

Gym layout ammended. Issued for comment.

E

11/09/15

Refuse Chute incorporated in to Plan. Store room added. Issued for comment.

D

13/08/15

External Facade revised. Townhouse stairs brought back to line flush with building. Issued for comment.

C

16/06/15

Issued for comment.

B

31/10/14

Landscaping revised and issued for Planning.

A

25/09/14

Issued for Planning.

CW 18

2D

3,240

25

L

RWO

RWO

6,400

24

W.B2.00.07 RWO

RWP

W.B2.00.13

Rainwater Outlet

B2-04-2201

4, 000

W.B2.00.15

RWO

Black

CW 27 W.B2.00.16

Stub Stack

RWP SVP

D.B2.00.30

D.B2.00.32

D.B2.00.02

B2.00.05 3 BED J2 G

B2.00.07 GUEST K1

D.B2.00.10

SS

B2.00.21 Laundrette

B2.00.23 Accessible WC

SS

AP

D.B2.00.01

D.B2.00.27

SS

B2.00.11 3 BED H3 G

SS

SS AP

Bury B2-04-2203

Rainwater Pipe

BULKHEAD

D.B2.00.11 B2.00.31 D.B2.00.14 Accessible WC AP D.B2.00.06

FIRE CURTAIN

D.B2.00.22

SS

SS

RWP

D.B2.00.29

B2.00.24 Store

Riser A

SS

SS

Soil Vent Pipe

LIFT.B2.A

B2.00.32 Refuse Store Chute Room SS Corridor

SVP

SVP

LIFT.B2.C

7, 450

CW 16

Access Panel

B2.00.20

LIFT.B2.B

B2.00.33 Post Store

AP

7,120

26

3,240

27

EE

CC

MP-05-2204

MP-05-2202

Garden B2-04-2202

6,400

28

6,400

6,400

29

30 BB

6,400

31

32

MP-05-2201

Trinity Salford Block 2

Ground Floor General Arrangement Plan

1:100 A1

05.09.14

JBe

MH

Tender

05366

_B2_02_2200

L


Copyright of this drawing is vested in 5plus Architect and it must not be copied or reproduced without written consent. Figured dimensions only are to be taken from this drawing. DO NOT SCALE OFF THIS DRAWING ...... IF IN DOUBT ASK

All contractors must visit the site and be responsible for taking and checking all dimensions relative to their work. 5plus architects are to be advised of any variation between drawings and site conditions.

Electronic data/ drawings issued as 'read only' and should not be interrogated for measurement. All dimensions and levels should be 'read only' from those values stated in text, on the drawings

B4 B5

B2 B3

B1

HEALTH & SAFETY For a complete list of health and safety notes refer to drawing MP_00_1200 In addition to the usual hazards associated with works of this nature the residual hazards are:-

!

05

Cleaning/Maintenance Risk of Falling

Podium B2-04-2204

9,628

9,572

9,640

7,120

9,640

6,400

12,800

W.B2.01.28 CW 24

CW 23

K E Y CW 25 W.B2.01.19

W.B2.01.20

W.B2.01.21

W.B2.01.22

W.B2.01.23

W.B2.01.24

W.B2.01.25

W.B2.01.26

W.B2.01.27

W.B2.01.29

DR

RWP

B2.01.20 Stairwell

W.B2.01.30

W.B2.01.31

W.B2.01.32

2A

W.B2.01.01

VOID

RWP

RWO

AP

Access Panel

SVP

Soil Vent Pipe

RWP

Rainwater Pipe

SS

Stub Stack

RWO

Rainwater Outlet

LIFT.B2.B

B2.01.10 1 BED E4

CW 26

B2.01.27 Lobby

B2.01.12 1 BED E4

4, 000

B2.01.09 1 BED E2 CW 16

STAIR CORE B2

B2.01.23 Fitness Studio

SVP SVP

B2.01.01 1 BED L2

LIFT.B2.C SVP

D.B2.01.21

2B

SVP

SVP

B2.01.25 Store

SS

Riser B

SS SVP

SVP SS

SVP SS

SVP SS

D.B2.01.28

B2.01.21 Lift Lobby

B2.01.26 Store

SVP RWP

AP

D.B2.01.04

AP

AP

AP

D.B2.01.05 D.B2.01.23

AP

AP AP

AP

AP

AP

D.B2.01.20

AP

AP

D.B2.01.06

D.B2.01.22

AP

D.B2.01.26

D.B2.01.01

B2.01.22 Common Corridor

D.B2.01.29

AP

AP

AP

D.B2.01.25

D.B2.01.02

D.B2.01.27 7, 450

L.B2.01.01

SVP RW P SVP

D.B2.01.03

SS

B2.01.04 3 BED J1 F

B2-04-2201

B2.01.07 3 BED H2 F

B2.01.06 3 BED H1F

SS

SVP

B2.01.24 Gym

B2.01.03 3 BED J2 F

2C

B2.01.05 3 BED H1 F

B2.01.02 1 BED L1

SVP

SVP

CW 30

RWO W.B2.01.17

W.B2.01.16

W.B2.01.15

W.B2.01.14 RWO

W.B2.01.13

W.B2.01.12

W.B2.01.11

RWO

W.B2.01.10

4, 000

B2.01.08 3 BED H3 F

SVP

SS

RW P

SS SVP

RW P

SVP

SS

SVP

SVP

SS

SS SVP

SVP

SS SS

SVP

SVP

Black

RWP

RWP RW P SVP

B2-04-2203

Riser A

RWP

SS

Bury

W. B2. 01. 18

SVP SS

SS SVP

SS SVP

B2.01.11 1 BED E6

SVP SS

B2. 01. 25 Cl eaner' s Cupboard / Chut e Room

LIFT.B2.A

RWO

RWP

RWP

W.B2.01.09

W.B2.01.08

W.B2.01.07

W.B2.01.06

W.B2.01.05

W.B2.01.04

W.B2.01.03

W.B2.01.02

CW 28

CW 29

J

08/03/16

Issued for Tender Package 02.

I

04/02/16

Amendment to core. Wall between lift and riser moved to accommodate larger lift for glass replacement strategy.

H

26/01/16

Tender Amendments - Gable louvres removed, window type amended and internal balustrade omitted. Podium core window amended and internal balustrade removed. Wardrobe amended from joinery item to door and clothing rail. Store doors amended and washing machines removed (services remain). Rain water outlets added to terraces. Amenity space amended, sauna and changing facilities omitted and replaced by gym and fitness studio, first floor cantilever omitted.

G

06/11/15

Issued for Tender.

F

03/11/15

Issued for Information and Comment

E

11/09/15

Refuse Chute added, Apartment layout revised. Issued for comment.

D

13/08/15

Upper floor Gym changing space revised. External facade revised. Issued for comment.

C

16/06/15

Issued for comment.

B

31/10/14

Amendments made to Plan and issued for Planning.

A

25/09/14

Issued for Planning.

2D

21

6,400

6,400

6,400

6,400

6,400

6,400

6,400

6,400

22

23

24

10,360

3,240

25

9,640

7,120

26

3,240

27

EE

CC

MP-05-2204

MP-05-2202

Garden B2-04-2202

6,400

6,400

28

12,800

6,400

6,400

29

30 BB

6,400

31

32

MP-05-2201

Trinity Salford Block 2

1st Floor General Arrangement Plan

1:100 A1

05.09.14

JBe

MH

Tender

05366

_B2_02_2201

J


Copyright of this drawing is vested in 5plus Architect and it must not be copied or reproduced without written consent. Figured dimensions only are to be taken from this drawing. DO NOT SCALE OFF THIS DRAWING ...... IF IN DOUBT ASK

All contractors must visit the site and be responsible for taking and checking all dimensions relative to their work. 5plus architects are to be advised of any variation between drawings and site conditions.

Electronic data/ drawings issued as 'read only' and should not be interrogated for measurement. All dimensions and levels should be 'read only' from those values stated in text, on the drawings

For all the wet area elevations please refer to interior designer's schedule.

B4 B5

B2 B3

B1

HEALTH & SAFETY

!

For a complete list of health and safety notes refer to drawing MP_00_1200 In addition to the usual hazards associated with works of this nature the residual hazards are:-

05

Cleaning/Maintenance Risk of Falling

Podium B2-04-2204

9,628

W.B2.02.28

9,572

W.B2.02.29

W.B2.02.30

W.B2.02.31

9,640

W.B2.02.32

W.B2.02.33

W.B2.02.34

7,120

W.B2.02.35

W.B2.02.36

6,452

W.B2.02.37

W.B2.02.38

6,375

W.B2.02.39

W.B2.02.40

6,385

W.B2.02.41

W.B2.02.42

9,628

W.B2.02.43

W.B2.02.44

W.B2.02.45

W.B2.02.01

W. B2. 02. 27

B2.02.20 Stairwell

LIFT.B2.B

B2.02.09 2 BED B1

B2.02.10 2 BED A3

STAIR CORE B2

B2.02.11 2 BED A2

B2.02.12 1 BED C1

B2.02.13 1 BED C2

B2.02.14 1 BED C1

4, 000

DR

W. B2. 02. 02

RW P

RW P

K E Y

2A

B2.02.01 2 BED B1

D.B2.02.21

SVP

SVP

Riser B

RWP

Rainwater Pipe

SS

Stub Stack

RWO

Rainwater Outlet

SVP

RWP D.B2.02.09

L.B2.02.01

AP

D.B2.02.10

AP

AP

AP

D.B2.02.11 D.B2.02.24

D.B2.02.08

AP

D.B2.02.07

AP

AP

D.B2.02.06

D.B2.02.20

AP

D.B2.02.23 D.B2.02.05

AP B2.02.22 Common Corridor

D.B2.02.12

D.B2.02.22 AP

AP

D.B2.02.04

D.B2.02.13

AP

AP

AP

D.B2.02.14

AP

D.B2.02.03

L.B2.02.02

D.B2.02.01

AP

D.B2.02.02

RWP

7, 450

SVP

RWP

W. B2. 02. 03

SVP W. B2. 02. 26

Soil Vent Pipe

B2.02.21 Lift Lobby SVP

Riser A

SVP

B2. 02. 23 Cl eaner' s Cupboard / Chut e Room

SVP

SVP

SVP

SVP

Black B2-04-2201

RWP SVP

SVP

SVP

RW P

SVP

SVP

RW P

SVP

SVP

RW P

SVP

SVP

SVP

SVP RW P SVP

SVP

2C SVP B2.02.03 2 BED A3

W.B2.02.24

W.B2.02.23

W.B2.02.22

W.B2.02.21

W.B2.02.20

9,628

W.B2.02.18

W.B2.02.17

9,572

6,400

21

W.B2.02.19

6,400

22

W.B2.02.16

W.B2.02.15

9,640

6,400

23

W.B2.02.14

W.B2.02.13

W.B2.02.12

7,120

6,400

24

B2.02.02 2 BED B2

3,240

25

3,240

27

EE

CC

MP-05-2204

MP-05-2202

Garden B2-04-2202

2D

W.B2.02.10

W.B2.02.09

9,640

7,120

26

W.B2.02.11

28

W.B2.02.08

W.B2.02.07

W.B2.02.06

9,572

6,400

J I

RW P

RW P

B2.02.04 2 BED A1

W. B2. 02. 04

B2.02.05 1 BED D1

B2.02.06 2 BED A1

B2.02.07 2 BED A3

4, 000

SVP B2.02.08 2 BED B2

W. B2. 02. 25

B2-04-2203

SVP

2B LIFT.B2.A

Bury

Access Panel

SVP SVP

SVP

AP

6,400

30 BB

08/03/16

Issued for Tender Package 02.

04/02/16

Amendment to core. Wall between lift and riser moved to accommodate larger lift for glass replacement strategy.

G

14/01/16

Tender Amendments - Balconies removed, window type amended and louvres added. Gable louvres removed, window type amended and internal balustrade omitted. Podium core window amended and internal balustrade removed. Wardrobe amended from joinery item to door and clothing rail. Store doors amended and washing machines removed (services remain).

W.B2.02.05

6,400

31

32

Issued for Tender - balconies reinstated

H

9,628

6,400

29

03/06/16

F

06/11/15

Issued for Tender.

E

03/11/15

Issued for Information and Comment.

D

11/09/15

Refuse Chute added, Apartment layout revised. Issued for comment.

C

13/08/15

External Facded revised. Issued for comment.

B

16/06/15

Issued for comment.

A

25/09/14

Issued for Planning.

MP-05-2201

Trinity Salford Block 2

2nd. 5th to 7th. 10th to 11th Floor

General Arrangement Plan 1:100 A1

05.09.14

JBe

MH

Tender

05366

_B2_02_2202

J


Copyright of this drawing is vested in 5plus Architect and it must not be copied or reproduced without written consent. Figured dimensions only are to be taken from this drawing. DO NOT SCALE OFF THIS DRAWING ...... IF IN DOUBT ASK

All contractors must visit the site and be responsible for taking and checking all dimensions relative to their work. 5plus architects are to be advised of any variation between drawings and site conditions.

Electronic data/ drawings issued as 'read only' and should not be interrogated for measurement. All dimensions and levels should be 'read only' from those values stated in text, on the drawings

For all the wet area elevations please refer to interior designer's schedule.

B4 B5

B2 B3

B1

HEALTH & SAFETY

!

For a complete list of health and safety notes refer to drawing MP_00_1200 In addition to the usual hazards associated with works of this nature the residual hazards are:-

05

Cleaning/Maintenance Risk of Falling

Podium B2-04-2204

9,628

W.B2.03.28

W.B2.03.30

W.B2.03.32

W.B2.03.33

W.B2.03.34

6,375

W.B2.03.35

W.B2.03.36

6,385

W.B2.03.37

W.B2.03.38

9,628

W.B2.03.39

W.B2.03.40

W.B2.03.41

K E Y

W.B2.03.01

RWO

DR

2A

B2.03.20 Stairwell

LIFT.B2.B

B2.03.10 1 BED E1 B2.03.09 2 BED B1

B2.03.11 2 BED A2

STAIR CORE B2

B2.03.12 1 BED C1

B2.03.13 1 BED C2

B2.03.01 2 BED B1

B2.03.14 1 BED C1

AP

Access Panel

SVP

Soil Vent Pipe

RWP

Rainwater Pipe

SS

Stub Stack

RWO

Rainwater Outlet

SVP SVP

SVP

4, 000

CW 21

W. B2. 03. 25

W.B2.03.31

6,452

W. B2. 03. 02

RWO

7,120

RW P

W.B2.03.27

9,640

RW P

W.B2.03.26

9,572

D.B2.03.21

2B

SVP

Riser B

SVP

B2.03.21 Lift Lobby SVP

Riser A

SVP

B2. 03. 23 Cl eaner' s Cupboard / Chut e Room

SVP

SVP

SVP

SVP

LIFT.B2.A

SVP

AP

D.B2.03.10

AP

AP

AP

D.B2.03.24

D.B2.03.11

D.B2.03.20 D.B2.03.08

AP

D.B2.03.07

AP

AP

D.B2.03.06

AP

D.B2.03.23 D.B2.03.05

D.B2.03.12

D.B2.03.22 AP

AP

B2.03.22 AP Common Corridor

D.B2.03.04

D.B2.03.13

AP

AP

AP

D.B2.03.14

AP

D.B2.03.03

L.B2.03.02

D.B2.03.01

AP

D.B2.03.02

RWP

7, 450

L.B2.03.01

W. B2. 03. 03

RWP D.B2.03.09

Black B2-04-2201

RWP SVP

SVP

SVP

RW P

SVP

SVP

RW P

SVP

SVP

RW P

SVP

SVP

SVP SVP

SVP

2C SVP B2.03.05 1 BED D1

B2.03.04 2 BED A1

B2.03.03 2 BED A3

B2.03.02 2 BED B2

W. B2. 03. 04

B2.03.06 2 BED A1

CW 21

RWO W.B2.03.22

W.B2.03.21

W.B2.03.20

W.B2.03.18

W.B2.03.17

9,572

6,400

6,400

22

J

03/06/16

Issued for Tender - balconies reinstated.

I

08/03/16

Issued for Tender Package 02.

H

04/02/16

Amendment to core. Wall between lift and riser moved to accommodate larger lift for glass replacement strategy.

G

14/01/16

Tender Amendments - Balconies removed, window type amended and louvres added. Gable louvres removed, window type amended and internal balustrade omitted. Podium core window amended and internal balustrade removed. Wardrobe amended from joinery item to door and clothing rail. Store doors amended and washing machines removed (services remain). Rain water outlets amended to inset terraces.

2D

RWO

9,628

21

RW P

B2.03.07 1 BED E1

4, 000

SVP B2.03.08 2 BED B2

RW P

B2-04-2203

SVP

RW P SVP

Bury

W. B2. 03. 24

SVP RWP

W.B2.03.16

W.B2.03.15

9,640

6,400

23

W.B2.03.13

W.B2.03.12

7,120

6,400

24

W.B2.03.14

3,240

25

3,240

27

EE

CC

MP-05-2204

MP-05-2202

Garden B2-04-2202

W.B2.03.10

W.B2.03.09

9,640

7,120

26

W.B2.03.11

W.B2.03.07

W.B2.03.06

9,572

6,400

28

W.B2.03.08

9,628

6,400

6,400

29

30 BB

W.B2.03.05

6,400

31

32

F

06/11/15

Issued for Tender.

E

03/11/15

Issued for Information and Comment.

D

11/09/15

Refuse Chute added, Apartment layout revised. Issued for comment.

C

13/08/15

External facade revised. Issued for comment.

B

16/06/15

Issued for comment.

A

25/09/14

Issued for Planning.

MP-05-2201

Trinity Salford Block 2

3rd to 4th Floor General Arrangement Plan

1:100 A1

05.09.14

JBe

MH

Tender

05366

_B2_02_2203

J


Copyright of this drawing is vested in 5plus Architect and it must not be copied or reproduced without written consent. Figured dimensions only are to be taken from this drawing. DO NOT SCALE OFF THIS DRAWING ...... IF IN DOUBT ASK

All contractors must visit the site and be responsible for taking and checking all dimensions relative to their work. 5plus architects are to be advised of any variation between drawings and site conditions.

Electronic data/ drawings issued as 'read only' and should not be interrogated for measurement. All dimensions and levels should be 'read only' from those values stated in text, on the drawings

For all the wet area elevations please refer to interior designer's schedule.

B4 B5

B2 B3

B1

HEALTH & SAFETY

!

For a complete list of health and safety notes refer to drawing MP_00_1200 In addition to the usual hazards associated with works of this nature the residual hazards are:-

05

Cleaning/Maintenance Risk of Falling

Podium B2-04-2204

9,628

W.B2.03.28

W.B2.03.30

W.B2.03.32

W.B2.03.33

W.B2.03.34

6,375

W.B2.03.35

W.B2.03.36

6,385

W.B2.03.37

W.B2.03.38

9,628

W.B2.03.39

W.B2.03.40

W.B2.03.41

K E Y

W.B2.03.01

RWO

DR

2A

B2.03.20 Stairwell

LIFT.B2.B

B2.03.10 1 BED E1 B2.03.09 2 BED B1

B2.03.11 2 BED A2

STAIR CORE B2

B2.03.12 1 BED C1

B2.03.13 1 BED C2

B2.03.01 2 BED B1

B2.03.14 1 BED C1

AP

Access Panel

SVP

Soil Vent Pipe

RWP

Rainwater Pipe

SS

Stub Stack

RWO

Rainwater Outlet

SVP SVP

SVP

4, 000

CW 21

W. B2. 03. 25

W.B2.03.31

6,452

W. B2. 03. 02

RWO

7,120

RW P

W.B2.03.27

9,640

RW P

W.B2.03.26

9,572

D.B2.03.21

2B

SVP

Riser B

SVP

B2.03.21 Lift Lobby SVP

Riser A

SVP

B2. 03. 23 Cl eaner' s Cupboard / Chut e Room

SVP

SVP

SVP

SVP

LIFT.B2.A

SVP

AP

D.B2.03.10

AP

AP

AP

D.B2.03.24

D.B2.03.11

D.B2.03.20 D.B2.03.08

AP

D.B2.03.07

AP

AP

D.B2.03.06

AP

D.B2.03.23 D.B2.03.05

D.B2.03.12

D.B2.03.22 AP

AP

B2.03.22 AP Common Corridor

D.B2.03.04

D.B2.03.13

AP

AP

AP

D.B2.03.14

AP

D.B2.03.03

L.B2.03.02

D.B2.03.01

AP

D.B2.03.02

RWP

7, 450

L.B2.03.01

W. B2. 03. 03

RWP D.B2.03.09

Black B2-04-2201

RWP SVP

SVP

SVP

RW P

SVP

SVP

RW P

SVP

SVP

RW P

SVP

SVP

SVP SVP

SVP

2C SVP B2.03.05 1 BED D1

B2.03.04 2 BED A1

B2.03.03 2 BED A3

B2.03.02 2 BED B2

W. B2. 03. 04

B2.03.06 2 BED A1

CW 21

RWO W.B2.03.22

W.B2.03.21

W.B2.03.20

W.B2.03.18

W.B2.03.17

9,572

6,400

6,400

22

J

03/06/16

Issued for Tender - balconies reinstated.

I

08/03/16

Issued for Tender Package 02.

H

04/02/16

Amendment to core. Wall between lift and riser moved to accommodate larger lift for glass replacement strategy.

G

14/01/16

Tender Amendments - Balconies removed, window type amended and louvres added. Gable louvres removed, window type amended and internal balustrade omitted. Podium core window amended and internal balustrade removed. Wardrobe amended from joinery item to door and clothing rail. Store doors amended and washing machines removed (services remain). Rain water outlets amended to inset terraces.

2D

RWO

9,628

21

RW P

B2.03.07 1 BED E1

4, 000

SVP B2.03.08 2 BED B2

RW P

B2-04-2203

SVP

RW P SVP

Bury

W. B2. 03. 24

SVP RWP

W.B2.03.16

W.B2.03.15

9,640

6,400

23

W.B2.03.13

W.B2.03.12

7,120

6,400

24

W.B2.03.14

3,240

25

3,240

27

EE

CC

MP-05-2204

MP-05-2202

Garden B2-04-2202

W.B2.03.10

W.B2.03.09

9,640

7,120

26

W.B2.03.11

W.B2.03.07

W.B2.03.06

9,572

6,400

28

W.B2.03.08

9,628

6,400

6,400

29

30 BB

W.B2.03.05

6,400

31

32

F

06/11/15

Issued for Tender.

E

03/11/15

Issued for Information and Comment.

D

11/09/15

Refuse Chute added, Apartment layout revised. Issued for comment.

C

13/08/15

External facade revised. Issued for comment.

B

16/06/15

Issued for comment.

A

25/09/14

Issued for Planning.

MP-05-2201

Trinity Salford Block 2

3rd to 4th Floor General Arrangement Plan

1:100 A1

05.09.14

JBe

MH

Tender

05366

_B2_02_2203

J


Copyright of this drawing is vested in 5plus Architect and it must not be copied or reproduced without written consent. Figured dimensions only are to be taken from this drawing. DO NOT SCALE OFF THIS DRAWING ...... IF IN DOUBT ASK

All contractors must visit the site and be responsible for taking and checking all dimensions relative to their work. 5plus architects are to be advised of any variation between drawings and site conditions.

Electronic data/ drawings issued as 'read only' and should not be interrogated for measurement. All dimensions and levels should be 'read only' from those values stated in text, on the drawings

For all the wet area elevations please refer to interior designer's schedule.

B4 B5

B2 B3

B1

HEALTH & SAFETY

!

For a complete list of health and safety notes refer to drawing MP_00_1200 In addition to the usual hazards associated with works of this nature the residual hazards are:-

05

Cleaning/Maintenance Risk of Falling

Podium B2-04-2204

9,628

W.B2.02.28

9,572

W.B2.02.29

W.B2.02.30

W.B2.02.31

9,640

W.B2.02.32

W.B2.02.33

W.B2.02.34

7,120

W.B2.02.35

W.B2.02.36

6,452

W.B2.02.37

W.B2.02.38

6,375

W.B2.02.39

W.B2.02.40

6,385

W.B2.02.41

W.B2.02.42

9,628

W.B2.02.43

W.B2.02.44

W.B2.02.45

W.B2.02.01

W. B2. 02. 27

B2.02.20 Stairwell

LIFT.B2.B

B2.02.09 2 BED B1

B2.02.10 2 BED A3

STAIR CORE B2

B2.02.11 2 BED A2

B2.02.12 1 BED C1

B2.02.13 1 BED C2

B2.02.14 1 BED C1

4, 000

DR

W. B2. 02. 02

RW P

RW P

K E Y

2A

B2.02.01 2 BED B1

D.B2.02.21

SVP

SVP

Riser B

RWP

Rainwater Pipe

SS

Stub Stack

RWO

Rainwater Outlet

SVP

RWP D.B2.02.09

L.B2.02.01

AP

D.B2.02.10

AP

AP

AP

D.B2.02.11 D.B2.02.24

D.B2.02.08

AP

D.B2.02.07

AP

AP

D.B2.02.06

D.B2.02.20

AP

D.B2.02.23 D.B2.02.05

AP B2.02.22 Common Corridor

D.B2.02.12

D.B2.02.22 AP

AP

D.B2.02.04

D.B2.02.13

AP

AP

AP

D.B2.02.14

AP

D.B2.02.03

L.B2.02.02

D.B2.02.01

AP

D.B2.02.02

RWP

7, 450

SVP

RWP

W. B2. 02. 03

SVP W. B2. 02. 26

Soil Vent Pipe

B2.02.21 Lift Lobby SVP

Riser A

SVP

B2. 02. 23 Cl eaner' s Cupboard / Chut e Room

SVP

SVP

SVP

SVP

Black B2-04-2201

RWP SVP

SVP

SVP

RW P

SVP

SVP

RW P

SVP

SVP

RW P

SVP

SVP

SVP

SVP RW P SVP

SVP

2C SVP B2.02.03 2 BED A3

W.B2.02.24

W.B2.02.23

W.B2.02.22

W.B2.02.21

W.B2.02.20

9,628

W.B2.02.18

W.B2.02.17

9,572

6,400

21

W.B2.02.19

6,400

22

W.B2.02.16

W.B2.02.15

9,640

6,400

23

W.B2.02.14

W.B2.02.13

W.B2.02.12

7,120

6,400

24

B2.02.02 2 BED B2

3,240

25

3,240

27

EE

CC

MP-05-2204

MP-05-2202

Garden B2-04-2202

2D

W.B2.02.10

W.B2.02.09

9,640

7,120

26

W.B2.02.11

28

W.B2.02.08

W.B2.02.07

W.B2.02.06

9,572

6,400

J I

RW P

RW P

B2.02.04 2 BED A1

W. B2. 02. 04

B2.02.05 1 BED D1

B2.02.06 2 BED A1

B2.02.07 2 BED A3

4, 000

SVP B2.02.08 2 BED B2

W. B2. 02. 25

B2-04-2203

SVP

2B LIFT.B2.A

Bury

Access Panel

SVP SVP

SVP

AP

6,400

30 BB

08/03/16

Issued for Tender Package 02.

04/02/16

Amendment to core. Wall between lift and riser moved to accommodate larger lift for glass replacement strategy.

G

14/01/16

Tender Amendments - Balconies removed, window type amended and louvres added. Gable louvres removed, window type amended and internal balustrade omitted. Podium core window amended and internal balustrade removed. Wardrobe amended from joinery item to door and clothing rail. Store doors amended and washing machines removed (services remain).

W.B2.02.05

6,400

31

32

Issued for Tender - balconies reinstated

H

9,628

6,400

29

03/06/16

F

06/11/15

Issued for Tender.

E

03/11/15

Issued for Information and Comment.

D

11/09/15

Refuse Chute added, Apartment layout revised. Issued for comment.

C

13/08/15

External Facded revised. Issued for comment.

B

16/06/15

Issued for comment.

A

25/09/14

Issued for Planning.

MP-05-2201

Trinity Salford Block 2

2nd. 5th to 7th. 10th to 11th Floor

General Arrangement Plan 1:100 A1

05.09.14

JBe

MH

Tender

05366

_B2_02_2202

J


Copyright of this drawing is vested in 5plus Architect and it must not be copied or reproduced without written consent. Figured dimensions only are to be taken from this drawing. DO NOT SCALE OFF THIS DRAWING ...... IF IN DOUBT ASK

All contractors must visit the site and be responsible for taking and checking all dimensions relative to their work. 5plus architects are to be advised of any variation between drawings and site conditions.

Electronic data/ drawings issued as 'read only' and should not be interrogated for measurement. All dimensions and levels should be 'read only' from those values stated in text, on the drawings

For all the wet area elevations please refer to interior designer's schedule.

B4 B5

B2 B3

B1

HEALTH & SAFETY

!

For a complete list of health and safety notes refer to drawing MP_00_1200 In addition to the usual hazards associated with works of this nature the residual hazards are:-

05

Cleaning/Maintenance Risk of Falling

Podium B2-04-2204

9,628

W.B2.02.28

9,572

W.B2.02.29

W.B2.02.30

W.B2.02.31

9,640

W.B2.02.32

W.B2.02.33

W.B2.02.34

7,120

W.B2.02.35

W.B2.02.36

6,452

W.B2.02.37

W.B2.02.38

6,375

W.B2.02.39

W.B2.02.40

6,385

W.B2.02.41

W.B2.02.42

9,628

W.B2.02.43

W.B2.02.44

W.B2.02.45

W.B2.02.01

W. B2. 02. 27

B2.02.20 Stairwell

LIFT.B2.B

B2.02.09 2 BED B1

B2.02.10 2 BED A3

STAIR CORE B2

B2.02.11 2 BED A2

B2.02.12 1 BED C1

B2.02.13 1 BED C2

B2.02.14 1 BED C1

4, 000

DR

W. B2. 02. 02

RW P

RW P

K E Y

2A

B2.02.01 2 BED B1

D.B2.02.21

SVP

SVP

Riser B

RWP

Rainwater Pipe

SS

Stub Stack

RWO

Rainwater Outlet

SVP

RWP D.B2.02.09

L.B2.02.01

AP

D.B2.02.10

AP

AP

AP

D.B2.02.11 D.B2.02.24

D.B2.02.08

AP

D.B2.02.07

AP

AP

D.B2.02.06

D.B2.02.20

AP

D.B2.02.23 D.B2.02.05

AP B2.02.22 Common Corridor

D.B2.02.12

D.B2.02.22 AP

AP

D.B2.02.04

D.B2.02.13

AP

AP

AP

D.B2.02.14

AP

D.B2.02.03

L.B2.02.02

D.B2.02.01

AP

D.B2.02.02

RWP

7, 450

SVP

RWP

W. B2. 02. 03

SVP W. B2. 02. 26

Soil Vent Pipe

B2.02.21 Lift Lobby SVP

Riser A

SVP

B2. 02. 23 Cl eaner' s Cupboard / Chut e Room

SVP

SVP

SVP

SVP

Black B2-04-2201

RWP SVP

SVP

SVP

RW P

SVP

SVP

RW P

SVP

SVP

RW P

SVP

SVP

SVP

SVP RW P SVP

SVP

2C SVP B2.02.03 2 BED A3

W.B2.02.24

W.B2.02.23

W.B2.02.22

W.B2.02.21

W.B2.02.20

9,628

W.B2.02.18

W.B2.02.17

9,572

6,400

21

W.B2.02.19

6,400

22

W.B2.02.16

W.B2.02.15

9,640

6,400

23

W.B2.02.14

W.B2.02.13

W.B2.02.12

7,120

6,400

24

B2.02.02 2 BED B2

3,240

25

3,240

27

EE

CC

MP-05-2204

MP-05-2202

Garden B2-04-2202

2D

W.B2.02.10

W.B2.02.09

9,640

7,120

26

W.B2.02.11

28

W.B2.02.08

W.B2.02.07

W.B2.02.06

9,572

6,400

J I

RW P

RW P

B2.02.04 2 BED A1

W. B2. 02. 04

B2.02.05 1 BED D1

B2.02.06 2 BED A1

B2.02.07 2 BED A3

4, 000

SVP B2.02.08 2 BED B2

W. B2. 02. 25

B2-04-2203

SVP

2B LIFT.B2.A

Bury

Access Panel

SVP SVP

SVP

AP

6,400

30 BB

08/03/16

Issued for Tender Package 02.

04/02/16

Amendment to core. Wall between lift and riser moved to accommodate larger lift for glass replacement strategy.

G

14/01/16

Tender Amendments - Balconies removed, window type amended and louvres added. Gable louvres removed, window type amended and internal balustrade omitted. Podium core window amended and internal balustrade removed. Wardrobe amended from joinery item to door and clothing rail. Store doors amended and washing machines removed (services remain).

W.B2.02.05

6,400

31

32

Issued for Tender - balconies reinstated

H

9,628

6,400

29

03/06/16

F

06/11/15

Issued for Tender.

E

03/11/15

Issued for Information and Comment.

D

11/09/15

Refuse Chute added, Apartment layout revised. Issued for comment.

C

13/08/15

External Facded revised. Issued for comment.

B

16/06/15

Issued for comment.

A

25/09/14

Issued for Planning.

MP-05-2201

Trinity Salford Block 2

2nd. 5th to 7th. 10th to 11th Floor

General Arrangement Plan 1:100 A1

05.09.14

JBe

MH

Tender

05366

_B2_02_2202

J


Copyright of this drawing is vested in 5plus Architect and it must not be copied or reproduced without written consent. Figured dimensions only are to be taken from this drawing. DO NOT SCALE OFF THIS DRAWING ...... IF IN DOUBT ASK

All contractors must visit the site and be responsible for taking and checking all dimensions relative to their work. 5plus architects are to be advised of any variation between drawings and site conditions.

Electronic data/ drawings issued as 'read only' and should not be interrogated for measurement. All dimensions and levels should be 'read only' from those values stated in text, on the drawings

For all the wet area elevations please refer to interior designer's schedule.

B4 B5

B2 B3

B1

HEALTH & SAFETY

!

For a complete list of health and safety notes refer to drawing MP_00_1200 In addition to the usual hazards associated with works of this nature the residual hazards are:-

05

Cleaning/Maintenance Risk of Falling

Podium B2-04-2204

9,628

W.B2.02.28

9,572

W.B2.02.29

W.B2.02.30

W.B2.02.31

9,640

W.B2.02.32

W.B2.02.33

W.B2.02.34

7,120

W.B2.02.35

W.B2.02.36

6,452

W.B2.02.37

W.B2.02.38

6,375

W.B2.02.39

W.B2.02.40

6,385

W.B2.02.41

W.B2.02.42

9,628

W.B2.02.43

W.B2.02.44

W.B2.02.45

W.B2.02.01

W. B2. 02. 27

B2.02.20 Stairwell

LIFT.B2.B

B2.02.09 2 BED B1

B2.02.10 2 BED A3

STAIR CORE B2

B2.02.11 2 BED A2

B2.02.12 1 BED C1

B2.02.13 1 BED C2

B2.02.14 1 BED C1

4, 000

DR

W. B2. 02. 02

RW P

RW P

K E Y

2A

B2.02.01 2 BED B1

D.B2.02.21

SVP

SVP

Riser B

RWP

Rainwater Pipe

SS

Stub Stack

RWO

Rainwater Outlet

SVP

RWP D.B2.02.09

L.B2.02.01

AP

D.B2.02.10

AP

AP

AP

D.B2.02.11 D.B2.02.24

D.B2.02.08

AP

D.B2.02.07

AP

AP

D.B2.02.06

D.B2.02.20

AP

D.B2.02.23 D.B2.02.05

AP B2.02.22 Common Corridor

D.B2.02.12

D.B2.02.22 AP

AP

D.B2.02.04

D.B2.02.13

AP

AP

AP

D.B2.02.14

AP

D.B2.02.03

L.B2.02.02

D.B2.02.01

AP

D.B2.02.02

RWP

7, 450

SVP

RWP

W. B2. 02. 03

SVP W. B2. 02. 26

Soil Vent Pipe

B2.02.21 Lift Lobby SVP

Riser A

SVP

B2. 02. 23 Cl eaner' s Cupboard / Chut e Room

SVP

SVP

SVP

SVP

Black B2-04-2201

RWP SVP

SVP

SVP

RW P

SVP

SVP

RW P

SVP

SVP

RW P

SVP

SVP

SVP

SVP RW P SVP

SVP

2C SVP B2.02.03 2 BED A3

W.B2.02.24

W.B2.02.23

W.B2.02.22

W.B2.02.21

W.B2.02.20

9,628

W.B2.02.18

W.B2.02.17

9,572

6,400

21

W.B2.02.19

6,400

22

W.B2.02.16

W.B2.02.15

9,640

6,400

23

W.B2.02.14

W.B2.02.13

W.B2.02.12

7,120

6,400

24

B2.02.02 2 BED B2

3,240

25

3,240

27

EE

CC

MP-05-2204

MP-05-2202

Garden B2-04-2202

2D

W.B2.02.10

W.B2.02.09

9,640

7,120

26

W.B2.02.11

28

W.B2.02.08

W.B2.02.07

W.B2.02.06

9,572

6,400

J I

RW P

RW P

B2.02.04 2 BED A1

W. B2. 02. 04

B2.02.05 1 BED D1

B2.02.06 2 BED A1

B2.02.07 2 BED A3

4, 000

SVP B2.02.08 2 BED B2

W. B2. 02. 25

B2-04-2203

SVP

2B LIFT.B2.A

Bury

Access Panel

SVP SVP

SVP

AP

6,400

30 BB

08/03/16

Issued for Tender Package 02.

04/02/16

Amendment to core. Wall between lift and riser moved to accommodate larger lift for glass replacement strategy.

G

14/01/16

Tender Amendments - Balconies removed, window type amended and louvres added. Gable louvres removed, window type amended and internal balustrade omitted. Podium core window amended and internal balustrade removed. Wardrobe amended from joinery item to door and clothing rail. Store doors amended and washing machines removed (services remain).

W.B2.02.05

6,400

31

32

Issued for Tender - balconies reinstated

H

9,628

6,400

29

03/06/16

F

06/11/15

Issued for Tender.

E

03/11/15

Issued for Information and Comment.

D

11/09/15

Refuse Chute added, Apartment layout revised. Issued for comment.

C

13/08/15

External Facded revised. Issued for comment.

B

16/06/15

Issued for comment.

A

25/09/14

Issued for Planning.

MP-05-2201

Trinity Salford Block 2

2nd. 5th to 7th. 10th to 11th Floor

General Arrangement Plan 1:100 A1

05.09.14

JBe

MH

Tender

05366

_B2_02_2202

J


Copyright of this drawing is vested in 5plus Architect and it must not be copied or reproduced without written consent. Figured dimensions only are to be taken from this drawing. DO NOT SCALE OFF THIS DRAWING ...... IF IN DOUBT ASK

All contractors must visit the site and be responsible for taking and checking all dimensions relative to their work. 5plus architects are to be advised of any variation between drawings and site conditions.

Electronic data/ drawings issued as 'read only' and should not be interrogated for measurement. All dimensions and levels should be 'read only' from those values stated in text, on the drawings

For all the wet area elevations please refer to interior designer's schedule.

B4 B5

B2 B3

B1

HEALTH & SAFETY

!

For a complete list of health and safety notes refer to drawing MP_00_1200 In addition to the usual hazards associated with works of this nature the residual hazards are:-

05

Cleaning/Maintenance Risk of Falling

Podium B2-04-2204

9,628

9,572

9,640

7,120

9,640

9,572

9,628

K E Y W.B2.08.28

W.B2.08.29

W.B2.08.30

W.B2.08.31

W.B2.08.32

W.B2.08.33

W.B2.08.34

W.B2.08.35

W.B2.08.36

W.B2.08.37

W.B2.08.38

W.B2.08.40 RWO

2A

RW P

DR B2.08.20 Stairwell

W.B2.08.01

LIFT.B2.B

B2.08.13 1 BED E3 B2.08.10 2 BED A3

B2.08.11 2 BED A2

B2.08.12 2 BED A1

STAIR CORE B2

6,050

2,890

B2.08.01 2 BED B1

2, 810

B2.08.09 2 BED B1

5, 710

Soil Vent Pipe

RWP

Rainwater Pipe

SS

Stub Stack

RWO

Rainwater Outlet

2, 100

SVP

Riser B

2,103

SVP

1,040

B2.08.21 Lift Lobby SVP

Riser A

SVP

B2. 08. 23 Cl eaner' s Cupboard / Chut e Room

SVP

SVP

SVP

SVP

SVP

SVP RWP

RWP D.B2.08.09

L.B2.08.01

AP

D.B2.08.10

AP

AP

D.B2.08.11

AP

D.B2.08.24 D.B2.08.20

D.B2.08.08

AP

D.B2.08.07

AP

AP

D.B2.08.06

AP

D.B2.08.23 D.B2.08.05

AP

D.B2.08.12

D.B2.08.22

AP

D.B2.08.13

AP

L.B2.08.02

D.B2.08.01

B2.08.22 Common Corridor

AP

AP

D.B2.08.04

AP

AP

D.B2.08.03

AP

D.B2.08.02

RWP

7, 450

SVP W. B2. 08. 24

SVP

2B

525

D.B2.08.21

LIFT.B2.A

Black B2-04-2201

RWP SVP

SVP

SVP

RW P

SVP

SVP

RW P

SVP

SVP

RW P

SVP

SVP

SVP

SVP RW P SVP

SVP

2C SVP B2.08.06 2 BED A1

B2.08.05 1 BED D1

B2.08.04 2 BED A1

B2.08.02 2 BED B2

W. B2. 08. 04

B2.08.07 2 BED A3

RW P

RW P

B2.08.03 1 BED E1

CW 21

W.B2.08.21

W.B2.08.20

W.B2.08.19

W.B2.08.18

9,628

W.B2.08.16

W.B2.08.15

9,572

6,400

21

W.B2.08.17

6,400

22

W.B2.08.14

W.B2.08.13

9,640

6,400

23

W.B2.08.11

W.B2.08.10

7,120

6,400

24

W.B2.08.12

3,240

25

26

3,240

27

EE

CC

MP-05-2204

MP-05-2202

Garden B2-04-2202

W.B2.08.09

W.B2.08.07

28

W.B2.08.06

9,572

6,400

03/06/16

Issued for Tender - balconies reinstated.

I

08/03/16

Issued for Tender Package 02.

H

04/02/16

Amendment to core. Wall between lift and riser moved to accommodate larger lift for glass replacement strategy.

G

14/01/16

Tender Amendments - Balconies removed, window type amended and louvres added. Gable louvres removed, window type amended and internal balustrade omitted. Podium core window amended and internal balustrade removed. Wardrobe amended from joinery item to door and clothing rail. Store doors amended and washing machines removed (services remain). Rain water outlets amended to inset terraces.

RWO

9,640

7,120

J

2D

RWO W.B2.08.22

4, 000

SVP B2.08.08 2 BED B2

W. B2. 08. 23

B2-04-2203

Access Panel

SVP SVP

SVP

Bury

AP

CW 21

W. B2. 08. 03

W. B2. 08. 25

RW P

RWO

W.B2.08.41

4, 000

W.B2.08.27

W. B2. 08. 02

W.B2.08.26

9,628

6,400

6,400

29

30 BB

W.B2.08.05

6,400

31

32

F

06/11/15

Issued for Tender.

E

03/11/15

Issued for Information and Comment.

D

11/09/15

Refuse Chute added, Apartment layout revised. Issued for comment.

C

13/08/15

External Facade revised. Issued for comment.

B

16/06/15

Issued for comment.

A

25/09/14

Issued for Planning.

MP-05-2201

Trinity Salford Block 2

8th to 9th Floor General Arrangement Plan

1:100 A1

05.09.14

JBe

MH

Tender

05366

_B2_02_2208

J


Copyright of this drawing is vested in 5plus Architect and it must not be copied or reproduced without written consent. Figured dimensions only are to be taken from this drawing. DO NOT SCALE OFF THIS DRAWING ...... IF IN DOUBT ASK

All contractors must visit the site and be responsible for taking and checking all dimensions relative to their work. 5plus architects are to be advised of any variation between drawings and site conditions.

Electronic data/ drawings issued as 'read only' and should not be interrogated for measurement. All dimensions and levels should be 'read only' from those values stated in text, on the drawings

For all the wet area elevations please refer to interior designer's schedule.

B4 B5

B2 B3

B1

HEALTH & SAFETY

!

For a complete list of health and safety notes refer to drawing MP_00_1200 In addition to the usual hazards associated with works of this nature the residual hazards are:-

05

Cleaning/Maintenance Risk of Falling

Podium B2-04-2204

9,628

9,572

9,640

7,120

9,640

9,572

9,628

K E Y W.B2.08.28

W.B2.08.29

W.B2.08.30

W.B2.08.31

W.B2.08.32

W.B2.08.33

W.B2.08.34

W.B2.08.35

W.B2.08.36

W.B2.08.37

W.B2.08.38

W.B2.08.40 RWO

2A

RW P

DR B2.08.20 Stairwell

W.B2.08.01

LIFT.B2.B

B2.08.13 1 BED E3 B2.08.10 2 BED A3

B2.08.11 2 BED A2

B2.08.12 2 BED A1

STAIR CORE B2

6,050

2,890

B2.08.01 2 BED B1

2, 810

B2.08.09 2 BED B1

5, 710

Soil Vent Pipe

RWP

Rainwater Pipe

SS

Stub Stack

RWO

Rainwater Outlet

2, 100

SVP

Riser B

2,103

SVP

1,040

B2.08.21 Lift Lobby SVP

Riser A

SVP

B2. 08. 23 Cl eaner' s Cupboard / Chut e Room

SVP

SVP

SVP

SVP

SVP

SVP RWP

RWP D.B2.08.09

L.B2.08.01

AP

D.B2.08.10

AP

AP

D.B2.08.11

AP

D.B2.08.24 D.B2.08.20

D.B2.08.08

AP

D.B2.08.07

AP

AP

D.B2.08.06

AP

D.B2.08.23 D.B2.08.05

AP

D.B2.08.12

D.B2.08.22

AP

D.B2.08.13

AP

L.B2.08.02

D.B2.08.01

B2.08.22 Common Corridor

AP

AP

D.B2.08.04

AP

AP

D.B2.08.03

AP

D.B2.08.02

RWP

7, 450

SVP W. B2. 08. 24

SVP

2B

525

D.B2.08.21

LIFT.B2.A

Black B2-04-2201

RWP SVP

SVP

SVP

RW P

SVP

SVP

RW P

SVP

SVP

RW P

SVP

SVP

SVP

SVP RW P SVP

SVP

2C SVP B2.08.06 2 BED A1

B2.08.05 1 BED D1

B2.08.04 2 BED A1

B2.08.02 2 BED B2

W. B2. 08. 04

B2.08.07 2 BED A3

RW P

RW P

B2.08.03 1 BED E1

CW 21

W.B2.08.21

W.B2.08.20

W.B2.08.19

W.B2.08.18

9,628

W.B2.08.16

W.B2.08.15

9,572

6,400

21

W.B2.08.17

6,400

22

W.B2.08.14

W.B2.08.13

9,640

6,400

23

W.B2.08.11

W.B2.08.10

7,120

6,400

24

W.B2.08.12

3,240

25

26

3,240

27

EE

CC

MP-05-2204

MP-05-2202

Garden B2-04-2202

W.B2.08.09

W.B2.08.07

28

W.B2.08.06

9,572

6,400

03/06/16

Issued for Tender - balconies reinstated.

I

08/03/16

Issued for Tender Package 02.

H

04/02/16

Amendment to core. Wall between lift and riser moved to accommodate larger lift for glass replacement strategy.

G

14/01/16

Tender Amendments - Balconies removed, window type amended and louvres added. Gable louvres removed, window type amended and internal balustrade omitted. Podium core window amended and internal balustrade removed. Wardrobe amended from joinery item to door and clothing rail. Store doors amended and washing machines removed (services remain). Rain water outlets amended to inset terraces.

RWO

9,640

7,120

J

2D

RWO W.B2.08.22

4, 000

SVP B2.08.08 2 BED B2

W. B2. 08. 23

B2-04-2203

Access Panel

SVP SVP

SVP

Bury

AP

CW 21

W. B2. 08. 03

W. B2. 08. 25

RW P

RWO

W.B2.08.41

4, 000

W.B2.08.27

W. B2. 08. 02

W.B2.08.26

9,628

6,400

6,400

29

30 BB

W.B2.08.05

6,400

31

32

F

06/11/15

Issued for Tender.

E

03/11/15

Issued for Information and Comment.

D

11/09/15

Refuse Chute added, Apartment layout revised. Issued for comment.

C

13/08/15

External Facade revised. Issued for comment.

B

16/06/15

Issued for comment.

A

25/09/14

Issued for Planning.

MP-05-2201

Trinity Salford Block 2

8th to 9th Floor General Arrangement Plan

1:100 A1

05.09.14

JBe

MH

Tender

05366

_B2_02_2208

J


Copyright of this drawing is vested in 5plus Architect and it must not be copied or reproduced without written consent. Figured dimensions only are to be taken from this drawing. DO NOT SCALE OFF THIS DRAWING ...... IF IN DOUBT ASK

All contractors must visit the site and be responsible for taking and checking all dimensions relative to their work. 5plus architects are to be advised of any variation between drawings and site conditions.

Electronic data/ drawings issued as 'read only' and should not be interrogated for measurement. All dimensions and levels should be 'read only' from those values stated in text, on the drawings

For all the wet area elevations please refer to interior designer's schedule.

B4 B5

B2 B3

B1

HEALTH & SAFETY

!

For a complete list of health and safety notes refer to drawing MP_00_1200 In addition to the usual hazards associated with works of this nature the residual hazards are:-

05

Cleaning/Maintenance Risk of Falling

Podium B2-04-2204

9,628

W.B2.02.28

9,572

W.B2.02.29

W.B2.02.30

W.B2.02.31

9,640

W.B2.02.32

W.B2.02.33

W.B2.02.34

7,120

W.B2.02.35

W.B2.02.36

6,452

W.B2.02.37

W.B2.02.38

6,375

W.B2.02.39

W.B2.02.40

6,385

W.B2.02.41

W.B2.02.42

9,628

W.B2.02.43

W.B2.02.44

W.B2.02.45

W.B2.02.01

W. B2. 02. 27

B2.02.20 Stairwell

LIFT.B2.B

B2.02.09 2 BED B1

B2.02.10 2 BED A3

STAIR CORE B2

B2.02.11 2 BED A2

B2.02.12 1 BED C1

B2.02.13 1 BED C2

B2.02.14 1 BED C1

4, 000

DR

W. B2. 02. 02

RW P

RW P

K E Y

2A

B2.02.01 2 BED B1

D.B2.02.21

SVP

SVP

Riser B

RWP

Rainwater Pipe

SS

Stub Stack

RWO

Rainwater Outlet

SVP

RWP D.B2.02.09

L.B2.02.01

AP

D.B2.02.10

AP

AP

AP

D.B2.02.11 D.B2.02.24

D.B2.02.08

AP

D.B2.02.07

AP

AP

D.B2.02.06

D.B2.02.20

AP

D.B2.02.23 D.B2.02.05

AP B2.02.22 Common Corridor

D.B2.02.12

D.B2.02.22 AP

AP

D.B2.02.04

D.B2.02.13

AP

AP

AP

D.B2.02.14

AP

D.B2.02.03

L.B2.02.02

D.B2.02.01

AP

D.B2.02.02

RWP

7, 450

SVP

RWP

W. B2. 02. 03

SVP W. B2. 02. 26

Soil Vent Pipe

B2.02.21 Lift Lobby SVP

Riser A

SVP

B2. 02. 23 Cl eaner' s Cupboard / Chut e Room

SVP

SVP

SVP

SVP

Black B2-04-2201

RWP SVP

SVP

SVP

RW P

SVP

SVP

RW P

SVP

SVP

RW P

SVP

SVP

SVP

SVP RW P SVP

SVP

2C SVP B2.02.03 2 BED A3

W.B2.02.24

W.B2.02.23

W.B2.02.22

W.B2.02.21

W.B2.02.20

9,628

W.B2.02.18

W.B2.02.17

9,572

6,400

21

W.B2.02.19

6,400

22

W.B2.02.16

W.B2.02.15

9,640

6,400

23

W.B2.02.14

W.B2.02.13

W.B2.02.12

7,120

6,400

24

B2.02.02 2 BED B2

3,240

25

3,240

27

EE

CC

MP-05-2204

MP-05-2202

Garden B2-04-2202

2D

W.B2.02.10

W.B2.02.09

9,640

7,120

26

W.B2.02.11

28

W.B2.02.08

W.B2.02.07

W.B2.02.06

9,572

6,400

J I

RW P

RW P

B2.02.04 2 BED A1

W. B2. 02. 04

B2.02.05 1 BED D1

B2.02.06 2 BED A1

B2.02.07 2 BED A3

4, 000

SVP B2.02.08 2 BED B2

W. B2. 02. 25

B2-04-2203

SVP

2B LIFT.B2.A

Bury

Access Panel

SVP SVP

SVP

AP

6,400

30 BB

08/03/16

Issued for Tender Package 02.

04/02/16

Amendment to core. Wall between lift and riser moved to accommodate larger lift for glass replacement strategy.

G

14/01/16

Tender Amendments - Balconies removed, window type amended and louvres added. Gable louvres removed, window type amended and internal balustrade omitted. Podium core window amended and internal balustrade removed. Wardrobe amended from joinery item to door and clothing rail. Store doors amended and washing machines removed (services remain).

W.B2.02.05

6,400

31

32

Issued for Tender - balconies reinstated

H

9,628

6,400

29

03/06/16

F

06/11/15

Issued for Tender.

E

03/11/15

Issued for Information and Comment.

D

11/09/15

Refuse Chute added, Apartment layout revised. Issued for comment.

C

13/08/15

External Facded revised. Issued for comment.

B

16/06/15

Issued for comment.

A

25/09/14

Issued for Planning.

MP-05-2201

Trinity Salford Block 2

2nd. 5th to 7th. 10th to 11th Floor

General Arrangement Plan 1:100 A1

05.09.14

JBe

MH

Tender

05366

_B2_02_2202

J


Copyright of this drawing is vested in 5plus Architect and it must not be copied or reproduced without written consent. Figured dimensions only are to be taken from this drawing. DO NOT SCALE OFF THIS DRAWING ...... IF IN DOUBT ASK

All contractors must visit the site and be responsible for taking and checking all dimensions relative to their work. 5plus architects are to be advised of any variation between drawings and site conditions.

Electronic data/ drawings issued as 'read only' and should not be interrogated for measurement. All dimensions and levels should be 'read only' from those values stated in text, on the drawings

For all the wet area elevations please refer to interior designer's schedule.

B4 B5

B2 B3

B1

HEALTH & SAFETY

!

For a complete list of health and safety notes refer to drawing MP_00_1200 In addition to the usual hazards associated with works of this nature the residual hazards are:-

05

Cleaning/Maintenance Risk of Falling

Podium B2-04-2204

9,628

W.B2.02.28

9,572

W.B2.02.29

W.B2.02.30

W.B2.02.31

9,640

W.B2.02.32

W.B2.02.33

W.B2.02.34

7,120

W.B2.02.35

W.B2.02.36

6,452

W.B2.02.37

W.B2.02.38

6,375

W.B2.02.39

W.B2.02.40

6,385

W.B2.02.41

W.B2.02.42

9,628

W.B2.02.43

W.B2.02.44

W.B2.02.45

W.B2.02.01

W. B2. 02. 27

B2.02.20 Stairwell

LIFT.B2.B

B2.02.09 2 BED B1

B2.02.10 2 BED A3

STAIR CORE B2

B2.02.11 2 BED A2

B2.02.12 1 BED C1

B2.02.13 1 BED C2

B2.02.14 1 BED C1

4, 000

DR

W. B2. 02. 02

RW P

RW P

K E Y

2A

B2.02.01 2 BED B1

D.B2.02.21

SVP

SVP

Riser B

RWP

Rainwater Pipe

SS

Stub Stack

RWO

Rainwater Outlet

SVP

RWP D.B2.02.09

L.B2.02.01

AP

D.B2.02.10

AP

AP

AP

D.B2.02.11 D.B2.02.24

D.B2.02.08

AP

D.B2.02.07

AP

AP

D.B2.02.06

D.B2.02.20

AP

D.B2.02.23 D.B2.02.05

AP B2.02.22 Common Corridor

D.B2.02.12

D.B2.02.22 AP

AP

D.B2.02.04

D.B2.02.13

AP

AP

AP

D.B2.02.14

AP

D.B2.02.03

L.B2.02.02

D.B2.02.01

AP

D.B2.02.02

RWP

7, 450

SVP

RWP

W. B2. 02. 03

SVP W. B2. 02. 26

Soil Vent Pipe

B2.02.21 Lift Lobby SVP

Riser A

SVP

B2. 02. 23 Cl eaner' s Cupboard / Chut e Room

SVP

SVP

SVP

SVP

Black B2-04-2201

RWP SVP

SVP

SVP

RW P

SVP

SVP

RW P

SVP

SVP

RW P

SVP

SVP

SVP

SVP RW P SVP

SVP

2C SVP B2.02.03 2 BED A3

W.B2.02.24

W.B2.02.23

W.B2.02.22

W.B2.02.21

W.B2.02.20

9,628

W.B2.02.18

W.B2.02.17

9,572

6,400

21

W.B2.02.19

6,400

22

W.B2.02.16

W.B2.02.15

9,640

6,400

23

W.B2.02.14

W.B2.02.13

W.B2.02.12

7,120

6,400

24

B2.02.02 2 BED B2

3,240

25

3,240

27

EE

CC

MP-05-2204

MP-05-2202

Garden B2-04-2202

2D

W.B2.02.10

W.B2.02.09

9,640

7,120

26

W.B2.02.11

28

W.B2.02.08

W.B2.02.07

W.B2.02.06

9,572

6,400

J I

RW P

RW P

B2.02.04 2 BED A1

W. B2. 02. 04

B2.02.05 1 BED D1

B2.02.06 2 BED A1

B2.02.07 2 BED A3

4, 000

SVP B2.02.08 2 BED B2

W. B2. 02. 25

B2-04-2203

SVP

2B LIFT.B2.A

Bury

Access Panel

SVP SVP

SVP

AP

6,400

30 BB

08/03/16

Issued for Tender Package 02.

04/02/16

Amendment to core. Wall between lift and riser moved to accommodate larger lift for glass replacement strategy.

G

14/01/16

Tender Amendments - Balconies removed, window type amended and louvres added. Gable louvres removed, window type amended and internal balustrade omitted. Podium core window amended and internal balustrade removed. Wardrobe amended from joinery item to door and clothing rail. Store doors amended and washing machines removed (services remain).

W.B2.02.05

6,400

31

32

Issued for Tender - balconies reinstated

H

9,628

6,400

29

03/06/16

F

06/11/15

Issued for Tender.

E

03/11/15

Issued for Information and Comment.

D

11/09/15

Refuse Chute added, Apartment layout revised. Issued for comment.

C

13/08/15

External Facded revised. Issued for comment.

B

16/06/15

Issued for comment.

A

25/09/14

Issued for Planning.

MP-05-2201

Trinity Salford Block 2

2nd. 5th to 7th. 10th to 11th Floor

General Arrangement Plan 1:100 A1

05.09.14

JBe

MH

Tender

05366

_B2_02_2202

J


Copyright of this drawing is vested in 5plus Architect and it must not be copied or reproduced without written consent. Figured dimensions only are to be taken from this drawing. DO NOT SCALE OFF THIS DRAWING ...... IF IN DOUBT ASK

All contractors must visit the site and be responsible for taking and checking all dimensions relative to their work. 5plus architects are to be advised of any variation between drawings and site conditions.

Electronic data/ drawings issued as 'read only' and should not be interrogated for measurement. All dimensions and levels should be 'read only' from those values stated in text, on the drawings

B4 B5

B2 B3

B1

HEALTH & SAFETY

!

For a complete list of health and safety notes refer to drawing MP_00_1200 In addition to the usual hazards associated with works of this nature the residual hazards are:-

05

Cleaning/Maintenance Risk of Falling

Podium B2-04-2204

K E Y

W.B1.12.31

RWO

RWO W.B1.12.24

D.B1.12.26

W.B1.12.25

W.B1.12.26

W.B1.12.27

W.B1.12.28

W.B1.12.29

W.B1.12.30

W.B1.12.32

DR

W.B1.12.33

W.B1.12.34

2A

W.B1.12.35

W.B1.12.36

W.B1.12.37

D.B1.12.23

B2.12.20 Stairwell

W. B1. 12. 38

AP

Access Panel

SVP

Soil Vent Pipe

RWP

Rainwater Pipe

SS

Stub Stack

RWO

Rainwater Outlet

W.B1.12.01

B2.12.09 1 BED E7

B2.12.10 1 BED E9

STAIR CORE B2

SVP

B2.12.08 1 BED E9

SVP

4, 000

LIFT.B2.B

B2.12.11 1 BED E10

SVP D.B2.12.21

2B

D.B2.12.28

D.B2.12.22

D.B2.12.06

AP

AP

D.B2.12.05

AP

D.B2.12.04

W. B1. 12. 02

SVP

AP

RW P

SVP

AP

D.B2.12.10

AP

D.B2.12.11

AP

AP

SVP

L.B2.12.02

B2.12.22 Common Corridor

D.B2.12.07 AP

SVP AP

D.B2.12.27

D.B2.12.09

D.B2.12.20 B2.12.07 2 BED G1

SVP

AP

B2. 12. 23 Cl eaner' s Cupboard / Chut e Room

AP

Riser B

B2.12.01 2 BED G1

D.B2.12.01 D.B2.12.03

AP

AP

D.B2.12.02

AP

RWO

RWO 7, 450

D.B2.12.08

SVP

AP

SVP

L.B2.12.01

B2.12.21 Lift Lobby

Riser A

W. B1. 12. 03

B2-04-2203

SVP

W. B1. 12. 22

RWO

Bury

RW P SVP

W. B1. 12. 23

LIFT.B2.A

Black B2-04-2201

RWO SVP SVP

RW P

SVP

SVP

RW P

SVP

SVP

RW P

SVP

SVP

W. B1. 12. 04

W. B1. 12. 21

SVP

RW P SVP

SVP

2C

B2.12.06 1 BED E9

W.B1.12.20

D.B1.12.25

W.B1.12.19

B2.12.05 1 BED E9

W.B1.12.18

W.B1.12.17

W.B1.12.16

B2.12.04 1 BED F1

W.B1.12.15

W.B1.12.14

B2.12.03 1 BED E9

W.B1.12.13

W.B1.12.12

W.B1.12.11

B2.12.02 1 BED E9

W.B1.12.10

W.B1.12.09

W.B1.12.08

RWO

6,778

6,400

21

22

9,640

6,400

23

W.B1.12.07

W.B1.12.06

D.B1.12.24

W.B1.12.05

7,120

6,400

24

3,240

25

9,640

7,120

26

3,240

27

EE

CC

MP-05-2204

MP-05-2202

Garden B2-04-2202

9,572

6,400

28

J

08/03/16

Issued for Tender Package 02.

I

04/02/16

Amendment to core. Wall between lift and riser moved to accommodate larger lift for glass replacement strategy.

H

14/01/16

Tender Amendments - Gable louvres removed, window type amended and internal balustrade omitted. Podium core window amended and internal balustrade removed. Wardrobe amended from joinery item to door and clothing rail. Store doors amended and washing machines removed (services remain). Louvre fin balustrade amended to verticle flat plate steel balustrade around full terrace. Perimeter column locations amended and gable columns increase in size.

G

06/11/15

Issued for Tender.

2D

RWO

9,572

6,400

4, 000

SVP

W. B1. 12. 39

SVP

6,778

6,400

6,400

29

30 BB

6,400

31

32

F

03/11/15

Issued for Information and Comment.

E

11/09/15

Refuse Chute added, Apartment layout revised. Issued for comment.

D

13/08/15

End apartment layouts revised. External facade revised. Issued for comment.

C

16/06/15

Issued for comment.

B

31/10/14

Amendments made to plan and issued for Planning.

A

25/09/14

Issued for Planning.

MP-05-2201

Trinity Salford Block 2

12th Floor General Arrangement Plan

1:100 A1

05.09.14

JBe

MH

Tender

05366

_B2_02_2212

J


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.