ECN October 2021

Page 38

SPECIAL FEATURE

CIRCUIT PROTECTION & SWITCHGEAR

EVOLUTION OF THE CONSUMER UNIT Darren Staniforth, Head of Technical Engagement at Scolmore Group, takes a look at how the consumer unit and, in particular, the devices within them are continuing to evolve to meet future requirements.

F

The small consumer unit may be a thing of the past

or many years, consumer units, which house essential circuit protection for domestic installations, have been fundamentally the same. However, the devices within the units have undergone almost constant change over the years. Advances in technology and manufacturing have brought about new methods of offering automatic disconnection of supply, short circuit protection and over current protection. Improvements in manufacturing has ensured that, today, these operations are offered by one common device. With protection against over voltage and arc fault taking centre stage recently, we need to look at how we can combine these devices to offer the maximum level of protection to the end users of installations well into the future.

market. Although our consumer units are fundamentally the same as our European counterparts, there were some teething problems. When first introduced, there wasn’t much mention of the need to coordinate them with an over current protective device. The next amendment to the wiring regulations saw changes that ensured designers and installers protected the surge protection device with an appropriate over current device. Some manufacturers then took it upon themselves to engineer their SPDs to incorporate over current protection or to offer it via a separate device. At the moment, choosing either of these solutions results in the loss of two outgoing ways within the consumer unit for many manufacturers. The race is now on to engineer a combined device that only occupies one outgoing way.

Surge protection

Arc fault detection devices are due to become commonplace, if, as Scolmore believes, the proposed changes to the wiring regulations make it through to the next amendment, which is due for publication in March 2022. Currently BS 7671 only recommends their use. However, the company has seen a number of early adopters embrace the technical merits of these devices and offer them to their clients. Scolmore has also had reports of clients asking for them until they realise the cost of the device. The current high cost of these means they are not a viable option for everyone. It is believed that AFDDs will be required for a number of final circuits supplying socket outlets. If this is the case, electrical installers will need to discuss the financial implications with their clients. Currently it is possible to enclose the AFDD technology within the same housing of many RCBOs. Many manufacturers have aimed to do this in a one module device. The challenge for many manufacturers was to keep the device height low enough to allow for the installation of cables above the device once it was installed.

Surge protection came into the UK wiring regulations many years after some of the continental European countries had mandated them. This saw manufacturers try to apply the solutions they were using in Europe to meet the needs of the UK

AFDDs

RCDs

“Advances in technology and manufacturing have brought about new methods of offering automatic disconnection of supply, short circuit protection and over current protection”

RCDs have seen a number of physical changes over the years and Scolmore believes the biggest change to the technology is still yet to come. These protective devices have historically been of Type AC and they were perfect for the older style installations with mostly resistive loads connected. In today’s world where gadgets are commonplace and lighting is mostly LED, we need an RCD that will continue to work with a small amount of residual DC present due to the connected loads. If the DC was allowed to sit across a Type AC device, the direct current could stop the device working within its maximum time as permitted by the UK regulations. It is understood that direct current can create DC blinding of the AC type RCD. This is why it is very important to select the most appropriate RCD to meet the need of the installation. Designers must ensure that the types of RCDs selected will ensure that DC sensitive devices will not be compromised by the DC present downstream. Currently type F and type B devices are hard to come by, but that could change if demand increases. Having more types of RCDs/RCBOs available will result in the designer needing to take note when using these different devices in one installation. Scolmore has chosen to only make Type A devices available in the new Elucian range of circuit protection. This has caught a few contractors out as they are relying on their old testers to test the new devices. A Type A device must be tested differently from the older style Type AC. Those that have not changed the settings on their test instrument to the new type have reported receiving high readings, very close to the maximum allowed. Others have reported the devices failed to disconnect within 40ms. The company says that as we move toward a prosumer future, the consumer unit that we understand today may look very different if many of the renewable and energy efficiency devices that are encouraged to be included in future installations are incorporated. The small consumer unit may be a thing of the past.  Scolmore, scolmore.com

3 Phase TPN Distribution Boards

Circuit Protection

www.niglon.co.uk | 0121 711 1990 | sales@niglon.co.uk 38  |  October 2021

Circuit Protection & Switchgear – Scolmore.indd 38

electricalcontractingnews.com

@ElecConNews

/electricalcontractingnews

@ecn_magazine

24/09/2021 12:23


Turn static files into dynamic content formats.

Create a flipbook

Articles inside

Company Showcase

17min
pages 77-84

Tipperary to upgrade lighting as part of a €5.7m project

3min
page 76

Energys Group completes over 70 LED lighting projects as part of PSDS scheme

3min
page 75

Veolia optimises lighting for one of the biggest Acute hospital trusts

2min
page 74

LED lighting – a revelation

4min
pages 70-73

Does street lighting offer the business case for future smart city development?

4min
pages 68-69

Don’t restrict yourself to lighting

5min
pages 62-63

Lighting the offices of the future

3min
pages 64-67

Spotlight on DALI

4min
pages 58-59

World famous university takes control of its light with state-of-the-art DALI solution

4min
pages 56-57

Thinking smarter is the way forward

6min
pages 54-55

Competition

2min
pages 52-53

ECN takes a look at the latest EV charger installation projects

4min
pages 50-51

Charge ahead with the EV opportunity and CEF

7min
pages 44-45

Ofgem to ensure electric car revolution unlocks full benefits for customers

2min
pages 48-49

Evolution of the consumer unit

4min
pages 38-41

Electrification and the growing opportunity for installers

3min
pages 46-47

‘Ready-to-go’ commercial SPD boards support need for best practice surge protection installation

6min
pages 34-37

Olson Electronics supplies PDU to Wire Broadcast

3min
pages 32-33

The kind of boom you want: why circuit protection devices are flying off the shelves

6min
pages 30-31

Key Issue

4min
pages 26-27

Contract News

8min
pages 17-19

Advertisement Feature

4min
pages 24-25

Training

3min
pages 20-21

Advertisement Feature

4min
page 16

Project Focus

2min
pages 22-23

Industry News

12min
pages 8-13

Editorial

2min
pages 6-7
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.