OPPORTUNITY KNOCKS
- 127 Chisholm Street -
Development opportunity in Central Business District zoning allowing for commercial use as well as residential. Concept drawings by Bill Hicks have been developed for a four storey 3 unit building that complies with all applicable bylaws and is ready for final design development and applications for development approvals. Proposed Units range in size from 3150 sq ft to 3350 sq ft, each with 650 sq ft terraces, double car parking, private elevators. Current home could be leased out or lived in and is not designated Heritage. Situated in a highly sought-after location, close to downtown Oakville, harbour and walking trails, and trendy Kerr Village, where an array of shops, restaurants, and entertainment options await. Similar projects being completed in the neighbourhood.
127 CHISHOLM STREET - 5
COMPLETED ZONING REVIEW
COMPLETED A PRE CONSULT MEETING WITH TOWN OF OAKVILLE
COMPLETED A HERITAGE PRE CONSULT WITH OAKVILLE
COMPLETED A ZONING REVIEW FOR THE PROPOSED BUILDING.
PREPARED CONCEPT DRAWINGS THAT ARE ADEQUATE TO INITIATE SITE PLAN APPROVAL BUT THIS PROCESS HAS NOW BEEN DELETED.
DRAWINGS ARE AT A FINAL DESIGN STAGE AND COULD BE USED TO COMPLETE THE TECHNICAL DRAWINGS AND PERMIT DRAWINGS.
CIVIL WORK HAS BEEN PREPARED
LANDSCAPE CONCEPT HAS BEEN PREPARED.
READY FOR FINAL DESIGN DEVELOPMENT AND APPLICATIONS FOR DEVELOPMENT APPROVALS
W O R K C O M P L E T E D REAL ESTATE GROUP A VIS T EAM
127 CHISHOLM STREET - 7
TREE PROTECTION
TREE PROTECTION BARRIERS
1. TREE PROTECTION BARRIERS MUST BE 1.2m (4'-0") HIGH, WAFERBOARD HOARDING OR AN EQUIVALENT APPROVED BY URBAN FORESTRY SERVICES.
2. TREE PROTECTION BARRIERS FOR TREES SITUATED ON THE TOWN ROAD ALLOWANCE WHERE VISIBILITY MUST BE MAINTAINED CAN BE 1.2m (4'-0") HEIGHT AND CONSIST OF ORANGE PLASTIC WEB SNOW FENCING ON A WOOD FRAME MADE OF 2"X4"'S.
3. WHERE SOME EXCAVATE OR FILL HAS TO BE TEMPORARILY LOCATED NEAR A TREE PROTECTION BARRIER, PLYWOOD MUST BE USED TO ENSURE NO MATERIAL ENTERS THE TREE PROTECTION ZONE.
4. ALL SUPPORTS AND BRACING SHOULD BE OUTSIDE THE TREE PROTECTION ZONE. ALL SUCH SUPPORTS SHOULD MINIMIZE DAMAGING ROOTS OUTSIDE THE TREE PROTECTION BARRIER.
5. NO CONSTRUCTION ACTIVITY, GRADE CHANGES, SURFACE TREATMENT OR EXCAVATIONS OF ANY KIND IS PERMITTED WITHIN THE TREE PROTECTION ZONE.
6. ALL LOCATES MUST BE OBTAINED PRIOR TO THE INSTALLATION OF THE PROPOSED HOARDING WITHIN THE MUNICIPAL RIGHT OF WAY.
SECTION 4, SIGNAGE
1. A SIGN (AS PER BELOW) MUST BE MOUNTED ON ALL SIDES OF A TREE PROTECTION BARRIER FOR THE DURATION OF THE PROJECT. THE SIGN SHOULD BE A MINIMUM OF 40cmX60cm AND MADE OF WHITE GATOR BOARD OR EQUIVALENT MATERIAL.
"TREE PROTECTION ZONE NO GRADE CHANGE, STORAGE OF MATERIALS OR EQUIPMENT IS PERMITTED WITHIN THIS AREA. THE TREE PROTECTION BARRIER MUST NOT BE REMOVED WITHOUT THE WRITTEN AUTHORIZATION OF THE TOWN OF OAKVILLE."
DN UP WOOD DECK WOOD SHED WOOD SHED 2 STOREY SIDING DWELLING No. 127 TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED TIMBER WALL BOARD FENCE BOARD FENCE DRAIN DRAIN ICV BB N51°28'40"W MH85.61 .1∅D 87.11 86.95 TMBR A/C86.86 COL EAVES EAVES EAVES 0.1∅C STK101 BRK Dist: 0.008m CUT 0.0 85.82 16.00 FILE No. 9560-SRPR-T P1=20R-2672 P2=20R-1319 P3=20R-15109 P4=FRED G. CUNNINGHAM INCORPORATED, O.L.S., SEP. 21, 1988 (LOT 3) P5=FRED G. CUNNINGHAM INCORPORATED, O.L.S., NOV. 13, 1997 (LOT 5&6) P6=FRED G. CUNNINGHAM INCORPORATED, O.L.S., JULY, 17, 2002 (LOT 2) P7=20R-14261 D1=624680 D2=743069 0.60 (P6&SET) 0.35 (P3,P6&SET) SIB 0.10 NW (N51°22'20"W P6) (12.19 P6) 1.28 (1.34 P6) 2.51 (2.50 P6) (16.00 P6) 0.31 (0.31 P6) 1.30 (1.34 P6) 4.09 (N51°52'40"W P4) (15.83 P4) 5.18 (P7&SET) 24.34 (P3&SET) 0.59 0.56 3.10 4.00 3.85 4.41 0.27 0.27 1.31 FACE OF WALL 0.10 NE 1.87 0.43 1.58 5.14 4.08 0.55 1.81 1.15 (P7&SET) 0.70 0.55 4.09 FACE OF WALL ON LINE 0.12 (P6&SET) (P3&SET) 24.34 86.29 86.58 86.93 87.31 87.56 37.77 87.38 85.62 86.3186.46 86.79 87.06 87.00 87.60 87.06 86.45 85.50 86.95 86.70 87.00 86.86 87.12 87.0787.21 87.40 87.34 87.45 87.6487.77 88.09 87.35 87.91 87.59 87.76 88.15 88.23 88.23 88.26 89.18 86.64 86.57 88.02 87.52 88.4288.68 88.30 87.44 87.05 87.18 87.02 86.87 86.69 86.71 86.74 87.44 87.19 87.23 88.17 87.46 87.26 86.99 87.04 86.65 86.62 86.82 86.73 86.80 86.46 87.0787.22 87.74 87.32 87.46 88.95 87.94 88.15 89.31 87.84 87.89 88.17 88.49 88.48 87.72 88.18 88.19 86.79 88.17 86.95 86.87 87.16 86.69 86.76 86.84 86.92 87.50 86.47 86.78 86.44 86.59 86.46 88.13 86.47 86.93 91.96 86.60 87.57 87.86 87.90 87.98 88.08 88.24 88.23 88.25 88.31 88.31 86.88 87.95 87.61 87.62 87.44 87.41 87.29 87.40 86.81 88.15 CONC. TIMBER WALL TRW TRW TRW TRW TRW TRW TRW TRW CB PAVED RIVER STONES ASPHALT DRIVEWAY ASPHALT DRIVEWAY PAVED C∅.15 CEDAR C∅0.1 6X0.2∅C D∅0.4 4X0.25∅C2X0.3∅C 3X0.3∅C 0.25∅C 0.25∅C 2X0.3∅C 3X0.25∅D CEDAR CEDAR STONE RETAINING WALL STONES PLANTER DOORSILL GARAGE SILL DOORSILL DOORSILL GARAGE SILL 2 STOREY STONE & STUCCO DWELLING No. 15 1 1 2 STOREY STUCCO DWELLING No. 131 DECK OVER STUCCO FOUNDATION WOOD DECK 2 STOREY SEMI STONE &STUCCO DWELLING No. 121 CANTILIVER DECK WOOD DECK 2 STOREY BRICK DWELLING No. 13 WOOD SHED CCT CCT CCT CCT TC TC BC BC BC BC BC WV CENTRELINE OF ASPHALT SIB IB IB(DISTURBED) 0.22 NE 0.04 NW IB CURB CUT CONCRETE CURB CONCRETE CURB CURB CUT PIN 24819-0026 PIN 24819-0145 PIN 24819-0136 PIN 24819-0012 PIN 24819-0121 PIN 24819-0139 PIN 24819-0144 PIN 24819-0011 PART 1 PLAN 20R-14261 PART 2 PLAN, 20R-14261 PART 21 PLAN 20R-13216 PART 7 PLAN 20R-13216 PLAN 20R-15109 PART 2 PART 1 PART 3 PART 2 REGISTERED PLAN 1 LOT 5 BLOCK 57 LOT 6 LOT 3 LOT 2 BOARD FENCE FENCE 0.17 SE FENCE 0.11 SW WROUGHT IRON FENCE GATE JOHN STREET ONAWAY ROAD 31.83 N38°02'20"E 36.54 N36°53'20"E 24.35 MEAS. N38°00'50"E 12.11 (P6&MEAS.) N51°28'40"W N51°35'30"W 15.77 (P3&SET) (BY REGISTERED PLAN 1) N38°00'50"E 12.13 N38°02'20"E 36.54 N36°53'20"E 24.35 N51°28'40"W 31.83 REBECCA STREET ∅150mm WATERMAIN ∅200mm SAN ∅300mm SAN ∅450mm STM 87.15 86.62 87.15 87.75 87.60 88.30 88.80 86.66 86.66 86.73 87.40 86.73 [86.60] [86.57] [86.47] + + + + + + + + + + + + + + + 1 3 1 2 2 4
NAME: TREE PROTECTION BARRIERS DATE: FILE NO.: TOWN OF OAKVILLE PARKS AND RECREATION DEPARTMENT SEE SECTION 4 FOR DETAILS SEE SECTION 4 FOR DETAILS SNOW FENCING EXIT PROPOSED BUILDING 4 STOREY RESIDENTIAL EXIT 1200 PROPOSED BUILDING 29.76 PROPOSED BUILDING 35.12 PROPOSED BUILDING 14.04 1200 120 800 496838 514 F.F.E. 88.30 TREE #5 TREE #4 TREE #3 TREE #1 TREE #7 TREE #8 TREE #9 TREE #10 TREE #11 TREE #13 TREE #12 TREE #2 TREE #6 36.54 5.49 5.69 9.17 6.48 1.42 24.42 2022-12-13 10:49:55 AM C:\Users\Christiana\Hicks Design Studio\HDS Documents\22-342 127 Chisholm\Drawings\127 Chisholm, Oakville Central_detached .rvt 1 : 150 1 Site Plan 1 : 1 2 OAKVILLE TREE PROTECTION REAL ESTATE GROUP A VIS T EAM
Drawings must NOT be scaled. Contractor must check and verify all dimensions, specifications and drawings on site and report any discrepancies to the architect prior to proceeding with any of the work.
PLANTER TIMBER WALL TO BE REMOVED TO BE REMOVED BB STU STU STU CONCRETE SIDEWALK 15.29 (P2&MEAS.) FACE OF WALL 0.38 NW 23.91 MEAS. 4.19 4.41 1.84 2.25 (P3&MEAS.) 2.96 0.47 (P2&SET) 4.05 1.48 1.67 0.91 (P8&SET) N38°20'10"E 2.23 88.40 87.85 88.46 88.43 88.36 88.33 88.23 88.11 88.06 87.76 40.35 40.36 87.94 88.78 88.39 39.38 87.80 88.0687.93 88.1688.08 88.13 88.07 88.23 88.12 88.28 88.3388.21 88.3788.26 88.39 88.43 87.79 88.47 89.71 88.74 88.64 88.80 87.9988.00 88.09 88.13 88.76 88.13 TIMBER WALL STONE WALL D∅0.2 0.2∅D DOORSILL WOOD DECK WOOD DECK STOREY WUP CCT CCT TC TC TC BC BC BC BC CENTRELINE OF ASPHALT MH MH MH SIB 0.06 NW 0.03 NE IP SIB IB SIB IB CT CT PIN 24819-0015 PART 3 PLAN 20R-2672 CHISHOLM STREET N38°02'20"E (D1&SET) 16.56 (BY REGISTERED PLAN 1) N51°35'30"W 16.56 N51°35'20"W 11.64 N51°35'30"W 15.04 36.54 EX. 200mm ∅ WATERMAIN EX. 150mm TEE EX. 200mm ∅ WATERMAIN TEE EX. 300mm ∅ PVC SAN EX. 200mm ∅ PVC SAN EX. 200mm ∅ PVC SAN EX. 200mm EX. 300mm EX. 300mm ∅ PVC SAN EX. 200mm ∅ PVC SAN EX. 375mm ∅ STM EX. ∅300mm STM EX. ∅450mm STM EX. 450mm EX. 375mm ∅ STM 300mm ∅ PVC STM 300mm ∅ PVC STM 87.99 88.10 [88.10] [88.40] 88.32 88.32 88.30 88.29 88.29 88.21 88.12 88.17 88.35 88.35 + + + + + + + + + + + + + + SITE LEGEND EXISTING TREE TO BE REMOVED MAIN ENTRANCE FINISHED FLOOR ELEVATION F.F.E PROPERTY LINE 83.57 EXISTING GRADE 700 PROPOSED DIMENSIONS TO NEW STRUCTURE 700 EXISTING EXISTING DIMENSIONS TO EXISTING STRUCTURE TREE PROTECTION BARRIER EXISTING TREE TO REMAIN. DASHED LINE INDICATES TPZ (TREE PROTECTION ZONE) AS PER ARBORIST REPORT TREE NUMBER AS PER ARBORIST REPORT TYP. PARKING DESIGN TREE #1 PARKING ENTRANCE MAIN RESIDENTIAL ENTRANCE PATHWAY SECOND FLOOR OVERHANG PROPERTY LINE DRIVEWAY 5.49 6.07 EXISTING CONCRETE SIDEWALK AND CURB TO BE REMOVED 1001 1324 FIRE DEPARTMENT SIAMESE CONNECTION EXISTING STONE WALL AND STEPS TO BE REMOVED ELECTRICAL POST TO REMAIN LOT FRONTAGE 16.56 NOTE: REFER TO SITE SERVICES DRAWINGS FOR ALL GRADING & PROPOSED SERVICE CONNECTIONS PROPOSED LOCATION OF GARBAGE & RECYCLING TOTE ON COLLECTION DAY TREE #14 SWM MH TREE #15 ARCHITECT & APPLICANT: HICKS DESIGN STUDIO 295 ROBINSON STREET, SUITE 200 OAKVILLE, ONTARIO L6J 1G7 ATTENTION: WILLIAM HICKS PH:905 339 1212 EXT:222 SITE STATISTICS: ADDRESS: LEGAL DESCRIPTION: ZONING: 127 CHISHOLM ST OAKVILLE, ON L6K 3J1 CBD SETBACKS: MAX. FRONT YARD 3m MAX. FLANKAGE YARD 3m MAX. NUMBER OF STOREYS- 4 MIN. FIRST STOREY HEIGHT 4.5m MAX. HEIGHT- 15m 1m 1.20m & 1.31m 4 4.5m 14.86m PROVIDED: LOT SIZE: REQUIRED: 523.98 m2 OWNER: GEOFFREY LUBERT ATTENTION: GEOFFREY LUBERT GEOFFREY_LUBERT@AJGRE.COM PH:416 318 2831 STANDARD PARKING SPACE 5700 2700 300 3000 PARKING SPACE NEAR WALL DRIVE AISLE 6000 5700 CLIENT: ADDRESS: CITY: DRAWING TITLE: DRAWN: DATE: JOB NUMBER: SCALE: SHEET NUMBER:
REVISIONS/ISSUANCE:
HICKS DESIGN STUDIO 295 ROBINSON STREET, SUITE 200 OAKVILLE ON, CAN L6J 1G7 WWW.HICKSDESIGNSTUDIO.CA T.905.339.1212 D E S I G N S T U D I O H I C K S As indicated 127 CHISHOLM STREET, OAKVILLE 22-342 A2.1 SITE PLAN 127 CHISHOLM CP 07/27/22 GFA (EXCLUDING PARKING) LEVEL AREA Ground Floor 80 m² Floor 2 363 m² Floor 3 363 m² Floor 4 345 m² Grand total 1151 m² RESIDENTIAL SALABLE AREA LEVEL AREA Floor 2 311 m² Floor 3 311 m² Floor 4 293 m² Grand total 916 m² TERRACES LEVEL AREA Floor 2 61 m² Floor 3 61 m² Floor 4 71 m² Grand total 193 m² SUBJECT PROPERTY N PARKING Name Level Area PARKING Ground Floor 301 m² PARKING PROVIDED LEVEL TYPE COUNT Ground Floor 2700X5700- Parking Space 5 Ground Floor 3000X5700- Parking Space 1 Grand total 6 COMMON AREAS LEVEL AREA Ground Floor 82 m² Floor 2 41 m² Floor 3 41 m² Floor 4 41 m² Grand total 206 m² 1 ISSUED FOR PRE-CONSULTATION MEETING 2022-08-17 NO DATE: DESCRIPTION GROUND FLOOR AREA LEVEL AREA Ground Floor 379 m² 2 ISSUED FOR SPA 2022-12-12 127 CHISHOLM STREET - 9
DN UP 500 2700 2700 4 3 2 1 A B D E F 6000 250 5700 290 250 5346 6856 6404 1521 6200 5800 35123 2836 2975 2866 5122 1200 3238.2 ft² 301 m² PARKING 1545 838 496 800 120 514 2700 2700 250 958 191 59.5 ft² 6 m² GARBAGE ROOM ALL WEATHER ALUMINUM LOUVERS STAIR #2 1380 FHC STANDPIPE 2.0% 467 86.81 86.81 87.92 87.92 300 1230 1452 1286 9569 1200 3072 1500 2022-12-13 10:49:55 AM C:\Users\Christiana\Hicks Design Studio\HDS Documents\22-342 127 Chisholm\Drawings\127 Chisholm, Oakville Central_detached .rvt REAL ESTATE GROUP A VIS T EAM
UP DRIVEWAY 5500 500 2700 3000 283 300 5 6 7 8 5500 815 2300 SPRINKLER/ METER RM 22921 29777 6395 4600 3923 1757 283 533 625 4110 2728 LOBBY 1200 MECH. ELEVATOR EXIT PATH 7720 5099 1324 900 ø1500 B.F.PUSH BUTTON ø 1500 B.F.PUSH BUTTON VEST. B.F.PUSH B.F.PUSH BUTTON 327 MAIL BOXES BARRIER FREE ENTRANCE OVERHEAD GARAGE DOOR STAIR #1 BUTTON B.F.PUSH BUTTON 239 2102 237 ALL WEATHER ALUMINUM LOUVERS 1467 1100 1100 183 1100 225 2140 1010 FIRE DEPARTMENT CONNECTION FHC STANDPIPE SAN. MH STM MH SWM MH 1.0% 88.30 88.34 88.34 STANDARD PARKING SPACE 5700 2700 300 3000 PARKING SPACE NEAR WALL DRIVE AISLE 6000 5700 CLIENT: ADDRESS: CITY: DRAWING TITLE: DRAWN: DATE: JOB NUMBER: SCALE: SHEET NUMBER: REVISIONS/ISSUANCE: Drawings must NOT be scaled. Contractor must check
verify all dimensions, specifications and drawings
site and
any discrepancies to the architect prior to proceeding with any of the work. HICKS DESIGN STUDIO 295 ROBINSON STREET, SUITE 200 OAKVILLE ON, CAN L6J 1G7 WWW.HICKSDESIGNSTUDIO.CA T.905.339.1212 D E S I G N S T U D I O H I C K S As indicated 127 CHISHOLM STREET, OAKVILLE 22-342 A3.2 GROUND FLOOR PLAN 127 CHISHOLM CP 13/07/22 N 1 ISSUED FOR PRE-CONSULTATION MEETING 2022-08-17 NO DATE: DESCRIPTION 2 ISSUED FOR SPA 2022-12-12 127 CHISHOLM STREET - 11
and
on
report
UP DN 4 3 2 1 A B D E F 6404 1521 6200 5800 2836 2975 2866 5122 6856 5346 1380 9555 462 ft² 42.91 m² MASTER BEDROOM 49 ft² 4.59 m² POWDER ROOM 33.63 510 ft² 47.38 m² LIVING 5993 15617 651.9 ft² 61 m² TERRACE 4446 BUILT IN PLANTER PLANTER 1200 35123 800 3100 1841 1100 386 1100 STAIR #2 1264 1186 7376 838 496 514 FHC STANDPIPE 1257 2022-12-13 10:49:56 AM C:\Users\Christiana\Hicks Design Studio\HDS Documents\22-342 127 Chisholm\Drawings\127 Chisholm, Oakville Central_detached .rvt REAL ESTATE GROUP A VIS T EAM
Drawings must NOT be scaled. Contractor must check and verify all dimensions, specifications and drawings on site and report any discrepancies to the architect prior to proceeding with any of the work.
DN UP 5 6 7 8 6395 4600 3923 14049 1186 3351.7 ft² 311 m² 2 BEDROOM APARTMENT 126 ft² 11.69 m² ENSUITE ROOM 62 ft² 5.78 m² PANTRY 362 ft² 33.63 m² DINING 311 ft² 28.88 m² KITCHEN 96 ft² 8.93 m² FOYER 7169 118 6197 4599 178 2891 105 4482 118 2351 118 ELEVATOR 3690 22700 73 ft² 6.79 m² LAUNDRY & MECH. 45 ft² 4.18 m² STAIR LOBBY 61 ft² 5.67 m² W.I.C. 1538 FURNACE WATER 6824 308 ft² 28.59 m² BEDROOM 265 ft² 24.61 m² OFFICE 127 ft² 11.77 m² WASHROOM 1660 1100 133 1100 2307 STAIR #1 1324 1232 900 FHC STANDPIPE CLIENT: ADDRESS: CITY: DRAWING TITLE: DRAWN: DATE: JOB NUMBER: SCALE: SHEET NUMBER:
REVISIONS/ISSUANCE:
HICKS DESIGN STUDIO 295 ROBINSON STREET, SUITE 200 OAKVILLE ON, CAN L6J 1G7 WWW.HICKSDESIGNSTUDIO.CA T.905.339.1212 D E S I G N S T U D I O H I C K S 1 : 50 127 CHISHOLM STREET, OAKVILLE 22-342 A3.3 SECOND AND THIRD FLOOR 127 CHISHOLM CP 10/15/21 N 1 ISSUED FOR PRE-CONSULTATION MEETING 2022-08-17 NO DATE: DESCRIPTION 2 ISSUED FOR SPA 2022-12-12 127 CHISHOLM STREET - 13
REAL ESTATE GROUP A VIS T EAM DN 4 3 2 1 A B D E F 464 ft² 43.11 m² MASTER BEDROOM 50 ft² 4.66 m² POWDER 34.04 DINING 650.8 ft² 60 m² TERRACE BUILT IN 4561 14919 7424 118 5993 6404 1521 6200 5800 6437 5765 2836 2975 2866 5122 1186 3100 1200 32900 1211 5765 250 506 ft² 46.97 m² LIVING STAIR #2 1100 386 1100 FHC STANDPIPE 2022-12-13 10:49:56 AM C:\Users\Christiana\Hicks Design Studio\HDS Documents\22-342 127 Chisholm\Drawings\127 Chisholm, Oakville Central_detached .rvt
Drawings must NOT be scaled. Contractor must check and verify all dimensions, specifications and drawings on site and report any discrepancies to the architect prior to proceeding with any of the work.
DN UP 5 6 7 8 126 ft² 11.70 m² ENSUITE 64 ft² 5.97 m² W.I.C. 62 ft² 5.78 m² PANTRY 45 ft² 4.18 m² STAIR LOBBY 102 ft² 9.45 m² ENSUITE 285 ft² 26.44 m² BEDROOM 366 ft² 34.04 m² DINING 117.5 ft² 11 m² TERRACE 274 ft² 25.43 m² KITCHEN 95 ft² 8.86 m² FOYER 164 ft² 15.22 m² STUDY ELEVATOR 178 2390 118 4563 4889 6230 118 3986 3363 118 4642 1045 283 797 436 2100 1050 2102 4488 2046 414 615 6395 4600 3923 20845 1871 896 1200 3155.0 ft² 293 m² 2 BEDROOM APARTMENT 14049 1747 1100 1100 133 1100 73 ft² 6.79 m² LAUNDRY & MECH. FURNACE WATER 6824 2351 118 3690 STAIR #1 915 1045 1324 FHC STANDPIPE CLIENT: ADDRESS: CITY: DRAWING TITLE: DRAWN: DATE: JOB NUMBER: SCALE: SHEET NUMBER: REVISIONS/ISSUANCE:
HICKS DESIGN STUDIO 295 ROBINSON STREET, SUITE 200 OAKVILLE ON, CAN L6J 1G7 WWW.HICKSDESIGNSTUDIO.CA T.905.339.1212 D E S I G N S T U D I O H I C K S 1 : 50 127 CHISHOLM STREET, OAKVILLE 22-342 A3.4 FOURTH FLOOR PLAN 127 CHISHOLM CP 07/21/22 N 1 ISSUED FOR PRE-CONSULTATION MEETING 2022-08-17 NO DATE: DESCRIPTION 2 ISSUED FOR SPA 2022-12-12 127 CHISHOLM STREET - 15
REAL ESTATE GROUP A VIS T EAM DN 4 3 2 1 A B D E F 6404 1521 6200 5800 2836 2975 2866 5122 BALCONY AT LEVEL 4 724 382 3328 9559 1376 1086 1072 GUARD SCREEN AROUND PERIMETER RESTING ON CONCRETE CURB FHC STANDPIPE STAIR #2 ROOFTOP UTILITY ACCESS DOOR ZINCO SEDUM MATS WITH PEASTONE ACCESS BORDER 2000 2022-12-13 10:49:57 AM C:\Users\Christiana\Hicks Design Studio\HDS Documents\22-342 127 Chisholm\Drawings\127 Chisholm, Oakville Central_detached .rvt
Drawings must NOT be scaled. Contractor must check and verify all dimensions, specifications and drawings on site and report any discrepancies to the architect prior to proceeding with any of the work.
DN 5 6 7 8 6395 4600 3923 896 2114 1086 786 12862 615 21073 749 2223 1210 ELEVATOR FHC STANDPIPE STAIR #1 193.1 ft² 18 m² Mechanical STAIR LOBBY 2920.6 ft² 271 m² Rooftop ZINCO SEDUM MATS WITH PEASTONE ACCESS BORDER 2671 5503 2338 2678 1986 2425 CLIENT: ADDRESS: CITY: DRAWING TITLE: DRAWN: DATE: JOB NUMBER: SCALE: SHEET NUMBER:
REVISIONS/ISSUANCE:
HICKS DESIGN STUDIO 295 ROBINSON STREET, SUITE 200 OAKVILLE ON, CAN L6J 1G7 WWW.HICKSDESIGNSTUDIO.CA T.905.339.1212 D E S I G N S T U D I O H I C K S 1 : 50 127 CHISHOLM STREET, OAKVILLE 22-342 A3.5 ROOF PLAN 127 CHISHOLM CP 05/13/22 1 2022-05-18 ISSUED FOR PRE-CONSULTATION MEETING N NO DATE: DESCRIPTION 2 ISSUED FOR SPA 2022-12-12 127 CHISHOLM STREET - 17
REAL ESTATE GROUP A VIS T EAM 4 3 2 1 A B D E F ZINCO SEDUM MATS W/ PEASTONE ACCESS BORDER 6404 1521 6200 5800 6811 3138 ROOF @ LEVEL 4 2022-12-13 10:49:58 AM C:\Users\Christiana\Hicks Design Studio\HDS Documents\22-342 127 Chisholm\Drawings\127 Chisholm, Oakville Central_detached .rvt
Drawings must NOT be scaled. Contractor must check and verify all dimensions, specifications and drawings on site and report any discrepancies to the architect prior to proceeding with any of the
5 6 7 8 ZINCO SEDUM MATS W/ PEASTONE ACCESS BORDER 6395 4600 3923 6721 8449 3994 2746 1448 9897 CLIENT: ADDRESS: CITY: DRAWING TITLE: DRAWN: DATE: JOB NUMBER: SCALE: SHEET NUMBER: REVISIONS/ISSUANCE:
HICKS DESIGN STUDIO 295 ROBINSON STREET, SUITE 200 OAKVILLE ON, CAN L6J 1G7 WWW.HICKSDESIGNSTUDIO.CA T.905.339.1212 D E S I G N S T U D I O H I C K S 1 : 50 127 CHISHOLM STREET, OAKVILLE 22-342 A3.6 HIGH ROOF PLAN 127 CHISHOLM CP 05/13/22 1 2022-05-18 ISSUED FOR PRE-CONSULTATION MEETING N NO DATE: DESCRIPTION 2 ISSUED FOR SPA 2022-12-12 127 CHISHOLM STREET - 19
work.
REAL ESTATE GROUP A VIS T EAM 1200 PROPERTY LINE FIRE DEPARTMENT CONNECTION LED EXTERIOR LIGHTING PRE-FINISHED METAL PARAPET CAP FLASHING PRE-FINISHED METAL PARAPET CAP FLASHING WOOD GRAIN ALUMINUM SIDING SYSTEM STUCCO TRIM SMOOTH (DARK GREY) STUCCO TRIM SMOOTH (DARK GREY) CONCRETE BASE THERMALLY BROKEN ALUMINUM WINDOW SYSTEM STUCCO TRIM SMOOTH (DARK GREY) BRICK CLADDING (DARK GREY) 2022-12-13 10:50:09 AM C:\Users\Christiana\Hicks Design Studio\HDS Documents\22-342 127 Chisholm\Drawings\127 Chisholm, OakvilleCentral_detached .rvt 1 : 50 1 South Elevation
Drawings must NOT be scaled. Contractor must check and verify all dimensions, specifications and drawings on site and report any discrepancies to the architect prior to proceeding with any of the work.
Ground Floor 88.1588.15 Floor2Floor2 92.6592.65 RoofRoof 103.01103.01 Floor3Floor3 95.9295.92 Floor4Floor4 99.1999.19 M.P.H.M.P.H. 105.91105.91 250 3820 3270 3270 4500 BUILDING HEIGHT 14.86 T/O Parapet 103.26103.26 2650 PROPERTY LINE 1324 INSULATED METAL SECTIONAL OVERHEAD DOOR C/W SPANDREL TRANSOM PANELS STUCCO BANDING SMOOTH (DARK GREY) THERMALLY BROKEN ALUMINUM WINDOW SYSTEM WOOD GRAIN ALUMINUM SIDING SYSTEM BRICK CLADDING (DARK GREY) STUCCO BAND SMOOTH (DARK GREY) CLIENT: ADDRESS: CITY: DRAWING TITLE: DRAWN: DATE: JOB NUMBER: SCALE: SHEET NUMBER: REVISIONS/ISSUANCE:
HICKS DESIGN STUDIO 295 ROBINSON STREET, SUITE 200 OAKVILLE ON, CAN L6J 1G7 WWW.HICKSDESIGNSTUDIO.CA T.905.339.1212 D E S I G N S T U D I O H I C K S 1 : 50 127 CHISHOLM STREET, OAKVILLE 22-342 A4.1 SOUTH ELEVATION 127 CHISHOLM CP 12/07/21 1 ISSUED FOR PRE-CONSULTATION MEETING 2022-08-17 2 ISSUED FOR SPA 2022-12-12 NO DATE: DESCRIPTION 127 CHISHOLM STREET - 21
REAL ESTATE GROUP A VIS T EAM
STUCCO TRIM SMOOTH (DARK GREY)
STUCCO (LIMESTONE LOOK FINISH)
THERMALLY BROKEN ALUMINUM WINDOW SYSTEM
2022-12-13 10:50:18 AM C:\Users\Christiana\Hicks Design Studio\HDS Documents\22-342 127 Chisholm\Drawings\127 Chisholm, OakvilleCentral_detached .rvt 1 : 50 1 North Elevation
GUARDRAIL SYSTEM W/ GLASS INSERTS
Drawings must NOT be scaled. Contractor must check and verify all dimensions, specifications and drawings on site and report any discrepancies to the architect prior to proceeding with any of the work.
Ground Floor 88.1588.15 Floor2Floor2 92.6592.65 RoofRoof 103.01103.01 Floor3Floor3 95.9295.92 Floor4Floor4 99.1999.19 M.P.H.M.P.H. 105.91105.91 2900 3820 3270 3270 4500 BUILDING HEIGHT 14.86 T/O Parapet 103.26103.26 STUCCO (LIMESTONE LOOK FINISH) CLIENT: ADDRESS: CITY: DRAWING TITLE: DRAWN: DATE: JOB NUMBER: SCALE: SHEET NUMBER:
REVISIONS/ISSUANCE:
HICKS DESIGN STUDIO 295 ROBINSON STREET, SUITE 200 OAKVILLE ON, CAN L6J 1G7 WWW.HICKSDESIGNSTUDIO.CA T.905.339.1212 D E S I G N S T U D I O H I C K S 1 : 50 127 CHISHOLM STREET, OAKVILLE 22-342 A4.2 NORTH ELEVATION 127 CHISHOLM CP 10/29/21 1 2022-08-17 ISSUED FOR PRE-CONSULTATION MEETING 2 ISSUED FOR SPA 2022-12-12 NO DATE: DESCRIPTION 127 CHISHOLM STREET - 23
REAL ESTATE GROUP A VIS T EAM BRICK CLADDING (DARK GREY) STUCCO BAND SMOOTH (DARK GREY) CONCRETE BASE PRE-FINISHED METAL PARAPET CAP FLASHING WOOD GRAIN ALUMINUM SIDING SYSTEM STUCCO TRIM SMOOTH (DARK GREY) 2022-12-13 10:50:32 AM C:\Users\Christiana\Hicks Design Studio\HDS Documents\22-342 127 Chisholm\Drawings\127 Chisholm, Oakville Central_detached .rvt 1 : 50 1 East Elevation
Drawings must NOT be scaled. Contractor must check and verify all dimensions, specifications and drawings on site and report any discrepancies to the architect prior to proceeding with any of the work.
Ground Floor 88.1588.15 Floor2Floor2 92.6592.65 RoofRoof 103.01103.01 Floor3Floor3 95.9295.92 Floor4Floor4 99.1999.19 M.P.H.M.P.H. 105.91105.91 4500 3270 3270 3820 2900 BUILDING HEIGHT 14.86 T/O Parapet 103.26103.26 STUCCO (LIMESTONE LOOK FINISH) GUARDRAIL SYSTEM W/ GLASS INSERTS CLIENT: ADDRESS: CITY: DRAWING TITLE: DRAWN: DATE: JOB NUMBER: SCALE: SHEET NUMBER:
REVISIONS/ISSUANCE:
HICKS DESIGN STUDIO 295 ROBINSON STREET, SUITE 200 OAKVILLE ON, CAN L6J 1G7 WWW.HICKSDESIGNSTUDIO.CA T.905.339.1212 D E S I G N S T U D I O H I C K S 1 : 50 127 CHISHOLM STREET, OAKVILLE 22-342 A4.3 EAST ELEVATION 127 CHISHOLM CP 10/15/21 1 2022-05-18 ISSUED FOR PRE-CONSULTATION MEETING 2 ISSUED FOR SPA 2022-12-12 NO DATE: DESCRIPTION 127 CHISHOLM STREET - 25
REAL ESTATE GROUP A VIS T EAM FIRE RATED DOOR PREFINISHED METAL PARAPET CAP FLASHING STUCCO (LIMESTONE LOOK FINISH) STUCCO TRIM SMOOTH (DARK GREY) 2022-12-13 10:50:46 AM C:\Users\Christiana\Hicks Design Studio\HDS Documents\22-342 127 Chisholm\Drawings\127 Chisholm, Oakville Central_detached .rvt 1 : 50 1 West Elevation
Drawings must NOT be scaled. Contractor must check and verify all dimensions, specifications and drawings on site and report any discrepancies to the architect prior to proceeding with any of the work.
Ground Floor 88.1588.15 Floor2Floor2 92.6592.65 RoofRoof 103.01103.01 Floor3Floor3 95.9295.92 UG1UG1 85.0585.05 Floor4Floor4 99.1999.19 M.P.H.M.P.H. 105.91105.91 2900 3820 3270 3270 4500 BUILDING HEIGHT 14.86 T/O Parapet 103.26103.26 BRICK CLADDING (DARK GREY) WOOD GRAIN ALUMINUM SIDING SYSTEM PRE-FINISHED METAL PARAPET CAP FLASHING SMOOTH CLIENT: ADDRESS: CITY: DRAWING TITLE: DRAWN: DATE: JOB NUMBER: SCALE: SHEET NUMBER:
REVISIONS/ISSUANCE:
HICKS DESIGN STUDIO 295 ROBINSON STREET, SUITE 200 OAKVILLE ON, CAN L6J 1G7 WWW.HICKSDESIGNSTUDIO.CA T.905.339.1212 D E S I G N S T U D I O H I C K S 1 : 50 127 CHISHOLM STREET, OAKVILLE 22-342 A4.4 WEST ELEVATION 127 CHISHOLM Author 11/14/22 2 ISSUED FOR SPA 2022-12-12 1 ISSUED FOR PRE-CONSULTATION MEETING 2022-08-17 NO DATE: DESCRIPTION 127 CHISHOLM STREET - 27
REAL ESTATE GROUP A VIS T EAM 2022-12-13 10:50:46 AM C:\Users\Christiana\Hicks Design Studio\HDSDocuments\22-342 127 Chisholm\Drawings\127 Chisholm, Oakville Central_detached .rvt
CLIENT: ADDRESS: CITY: DRAWING TITLE: DRAWN: DATE: JOB NUMBER: SCALE: SHEET NUMBER: REVISIONS/ISSUANCE: Drawings must NOT be scaled. Contractor must check and verify all dimensions, specifications and drawings on site and report any discrepancies to the architect prior to proceeding with any of the work. HICKS DESIGN STUDIO 295 ROBINSON STREET, SUITE 200 OAKVILLE ON, CAN L6J 1G7 WWW.HICKSDESIGNSTUDIO.CA T.905.339.1212 D E S I G N S T U D I O H I C K S 127 CHISHOLM STREET, OAKVILLE 22-342 A6.1 3D 127 CHISHOLM CP 10/15/21 1 ISSUED FOR PRE-CONSULTATION MEETING 2022-08-17 1 ISSUED FOR SPA 2022-12-12 NO DATE: DESCRIPTION 127 CHISHOLM STREET - 29
ABOUTOWNE REALTY CORP., BROKERAGE. INDEPENDENTLY OWNED AND OPERATED Realty Corp., Brokerage. Independently Owned and Operated A-309 Lakeshore Rd. E., Oakville ON, L6J 1J3 Not intended to solicit properties already listed for sale Office: 905.338.9000 | www.avisteam.com | @theavisteam BROKER Cindy Avis C: 905.334.8728 cindy@avisteam.com