STRUCTURAL DESIGN
The Structural Design of the NHM office building has been done with Earthquake loads of Bhopal, using STAAD.Pro software. The Design is IS-456 Code complaint and has been done for M-30 Grade of concrete and Fe-550 Reinforcement Bars. A few screenshots have been attached as the following figures for showcasing the
The design employs 4 types of typical beams sections and 5 types of typical column sections in the entire project. Precast Concrete can be used as recommended material to reduce construction time of project. This enables Perfect casting and best fitting of components. Such a project can be made airtight easily and shall be affordable to implement. The structure considers a water tank on top of primary toilet complex and green roofs Figure 77. Foundation Footing and Column Layout with special structural care given to accessible rooftops and green roofs. A conventional rigid from structure has been proposed for easier implementation on site and if need be can be converted into an in-situ casted construction process. Figure 78. Typical footing Section
Figure 79. Columns and beams section 37